View Bid Results For Note Detection Machine Tenders

We found 136 Bid Results related to note detection machine tenders. You can find Contractor details who won note detection machine tenders along with contract details in Bid awards announcements section.

Filters
Stage
98
25
13
Tender Publishing Platform
12
124
State / UT
24
18
18
16
11
9
7
7
6
5
4
4
4
4
3
3
3
2
2
2
2
2
2
1
1
Contract Value
43
16
41
32
Publish Date
0
0
0
0
0
Sector
18
47
17
14
14
13
7
3
3
3
3
2
2
2
2
1
1
1
1
Ownership
4
55
53
14
14
Within keyword
Active filters:
Showing 1–3 of 136 tenders matching your filters
1.
Home Affairs #11284599 Technical Bid
Tender for Stationaryarticles / Printing Of Govt. Forms & Register / Computer Aricales / Miscellanies Articales. , Stationary Items , Alpin , Binder Clip (Medium) , Car Diary , Carbon Paper (219 Mm X 330 Mm) , Cartridge Reffiling , Cello Tape (0.5) , Cello Tape (1) , Cello Tape 2 , Channel File (A4 Size) , Channel File Plastic (Fs Size) , Clip Board , completion Paper A4 Size , completion Paper Legal , Epson Ink Tank Printer , Cotton Tag , Cover File , Dvd With Packet , Envelop White , Envelope (11 X 5) Brown Paper Made , Envelope (A4) White Cloth Lyning , Envelope (Legal) White Cloth Lyning , Envelope (11X5) White Cloth Lyning , Eraser Non Dust , Executive Bond Paper A4 Size , Fevistick , File Binder , Folder File , Folder File Paper Made Printed , Four Folder File , Foil Paper , G.P.F. Register 200 Pgs. , Gel Pen Pilot , Gel Refil Add Achiever , Gum 700 Ml , Highlighter Pen , Issue Voucher Book (10 X 12) , James Clip Plastic , James Clip Steel , Leave Register 100 Folio , Leave Register 200 Folio , L-Shape Folder File , Marker Pen , Hp Laser Jet All In One Printer , Miscellaneous Stock Book 500 Folio , Muster Roll 400 Folio , New Year Calender , New Year Diary , Note Book , Note Sheet Page , Office Calculator Machine , Order Book 200 Page , Paper Weight , Pay Hold Register Binding 200 Pages , Pen Dot/Ball , Pen Stand , Pencil Wooden , Peon Book , Photo Paper , Pin Pot , Planner , Steel Scale 12 , Plastic Scale 12 , Pocket Diary , Punching Machine Single , Punishment Register Board Binding 200 Pages , Register Board Binding 100 Pages , Register Board Binding 200 Pages , Register Board Binding 300 Pages , Register Board Binding 400 Pages , Register Board Binding 500 Pages , Register Board Binding 600 Pages , Reward Register Board Binding 200 Pages , Ring Binder File , Scissors Stainless Steel Length 8.5 , Service Book , Sharpner , Special Letter Pad Bond Paper 100 Gsm (11 X 8) , Stamp Pad Big 95 Mm X 159 Mm (Pvc) , Stamp Polymer Rubber , Stapler Machine Small , Stapler Machine (Big) , Stapler Pin (Big) , Stapler Pin (Small) , Sticky Note , Stock Book Board Binding 300 Pages , Thread Ball , Uniball Pen , Use & Throw Pen , Whitener , Board Duster , Metal Polish , Usb Wire Mouse , Wirless Mouse , Usb Wire Combo Pack , Wireless Combo Pack , Usb Wire Key Board , Wireless Key Board , 500 Gb Sata (With Power/Data Cable) 2.5/3.5 Inch , 1 Tb Sata (With Power/Data Cable) 2.5/3.5 Inch , 2 Tb Sata (With Power/Data Cable) 2.5/3.5 Inch , 500 Gb External Hard Disc , 1 Tb External Hard Disc , 2 Tb External Hard Disc , 4 Tb External Hard Disc , 8 Tb External Hard Disc , 500 Gb Sata (With Power & Data Cable) , 500 Gb Ssd , 1 Tb Ssd , 2 Tb Ssd , 4 Tb Ssd , 8 Tb Ssd , 1 Tb Internal Hard Disc , 2 Tb Internal Hard Disc , 4 Tb Internal Hard Disc , 8 Tb Internal Hard Disc , External Dvd Writer Usb , Internal Dvd Writer With Sata/Power Cable , Atx 450Watt Smps , Ats 500 Watt Smps , Ats 1000 Watt Smps , 700 Va Ups , 1 Kva Ups , Gigabite (10/100/1000) Pci Slot , Gigabite (10/100/1000) Usb Wifi , Gigabite (10/100/1000) Usb Ethernet (Rj-45) , 16 Gb Pendrive , 32 Gb Pendrive , 64 Gb Pendrive , 128 Gb Pendrive , 256 Gb Pendrive , 512 Gb Pendrive , 16 Gb Sd Card , 32 Gb Sd Card , 64 Gb Sd Card , 128 Gb Sd Card , 256 Gb Sd Card , 500 Gb Sd Card , All Type Of Mnc Combo Card Reader , Power Bank 20000 Mh , 3.5 Mm- Head Phone With Microphone , Usb- Head Phone With Microphone , Normal Sound Box , Cabinet For Pc , Laptop Battery , Vga Display Cable , Hdmi Display Cable (4K) , Hd Display Cable , Vga Display Cable (20 Mtr.) , Hdmi Display Cable (4K) (20 Mtr.) , Hd Display Cable (20 Mtr.) , D-Link -Cat-6 Cable 305 Mtr. Box , D-Link-Cat-6-Patch- Cord 3 Mtr. , D-Link-Cat-6-Patch- Cord 10 Mtr. , 8 Port Gigabite Switch (10/100/100) , 24 Port Gigabite Switch (10/100/100) , Wirless Router Gigabite , 6-U Complete Rack (Cooling Fan+ Power Board) , 9-U Complete Rack (Cooling Fan+ Power Board) , 12-U Complete Rack (Cooling Fan+ Powerboard) , Io Box Complete Set , Rj-45 Connector D-Link Box , Rj-45 Connector Crimping Tool , Lan Testing Meter , Io Box Punching Tool , Electric Drill Kit Set , Cable Cutter , Screwdriver Set For Computer / Laptop , Air Blower , Tools Keeping Box , Ladder , Laser Pointer , Wireless Presenter , Bios Battery , Ddr-4 Ram- 4 Gb , Ddr-4 Ram -8 Gb , Ddr-4 Ram -16 Gb , L-3250- Maintenance Box Black , M1180- Maintenance Box , M2711- Maintenance Box , L 6460- Maintenance Box Colour , Laptop Screen , Canon Laser Toner , Epson Laser Toner , Epson Black Ink 005 , Epson Colour Ink Set 008 , Brothers Printer Ink Set , Usb To Rj-45 Lan / Rj-45 Lan To Usb , Hdmi To Usb / Usb To Hdmi , Vga To Hdmi / Hdmi To Vga , One Display To Multiple Display (Display Switch) , Multiple Display To One Display (Display Switch) , Multy Sound Convertar , Multiple Lan Connector , Usb To 3.5 Mm Jack / 3.5 Mm Jack To Usb , Laptop Mother Board , Epson Ink 001 Set , Video Editing Card , Cd / Dvd (R) Box With Pouch Pack , Display / Vga Card Pci Slot , Mother Board For Desktop , Laptop I-7(Latest Version) , 5 annual periodical maintenance Power Cable , 15 annual periodical maintenance Power Cable , Sata Cable (Data) , Sata Cable (Power) , Usb Cable , 8 Channel Dvr / Nvr , 16 Channel Dvr / Nvr , 8 Port Poe Switch , 16 Port Poe Switch , Ip- Dom Camera With Night Vishon , Ip - Bullet Camera With Night Vishon , Spy Camera , Digital Camera , Body Camera , Xerox Machine Toner , 6 Inches Binding Ties , 10 Nches Binding Ties , Binding Tag Large , Micro Oven , Spike Guard Long Cable , Smart Tv 55 , I-3 Processor , I-5 Processor , I-7 Processor , Total Security 10 Users 1 Year , Total Security 10 Users 3 Years , Protable Printer Ink Set(Canon Pixma) , Misc Items , Air Purifier , Aluminium Channel Door , Aluminium Channel Window , Aluminium Hanger , Aluminium Pipe , B.P. Machine , Badminton Racket , Badminton Net , Badminton Shuttle Cock , Bamboo , Banner , Basin Brush. , Bathroom Wiper , Pencil Battery Aaa , Pencil Battery Aa , Mixer Grinder , Bed Sheet ( Double Bed) , Bed Sheet ( Single Bed) , Stand Fan , Ceilling Fan , Big Towel , Big Unit T Flag , Black Board With Iron Stand , Bleaching Powder , Blow Lamp , Board Pvc , Board Pvc , Board Pvc , Board Pvc , Board Pvc , Bone Dust , Bottle Socket , Bowl Set (Medium) , Book Self (Depth 2) Wood Made , Bowl Set (Small) , Brass Flower Tub Standard Size , Brass Letter , Brass Name Plate , Brass Pad Lock Six Lever , Bricks , Broom Stick , Bulb Led15 Wt. , Bulb Led10wt , Bulb Holder , Bulb Philips 200 Watt , C.F.L Tube 35 Wt , Cabinet For Box 24 Inch. , Smart Phone , Calling Bell With Remote , Candle , Cane Basket , Cap Stand , Car Freshner , Carbolic Acid 500 Ml , 1.5 Ton Ac Hitachi , Cooking Unensill Set Steel , Tea Table , Cashing Bottom , Cashing Bottom , Cashing Bottom , Cashing Box , Cashing Box , Cassing Board , Cassing Wiring , Cat 6 Cable , Celing Fan With Wire And Fitting Hiring Charge Per Day , Cement , Cement , Cement Primer , Cfl Philips , Changer 63 annual periodical maintenance , Charger For Re Chargeable Search Light - Standard , Chemical Lime , Cherry Blossom Liquid , Cotton Bag Large Size , Cleaning Mop , Cloth Markin , Coffee Powder , Coir Mat 36/18 , Coir Rope , Colin 500Ml , Coller Microphone , Condencer For Fan , Copper Cable 10 Mm , Copper Wire 16 Mm , Core Cable 2.5 , Core Cable1.1 , Core Cable1.5 , Cotton , Cricket Ball , Cricket Bat , Cup & Plate Set , Currency Count With Fake Note Detection Machine , Curtain Full Set , Polycarbon Stick , Dettol Soap , Decoration Pipe 6 , Decoration Flag , Detergent Powder , Dinner Set (6 Pcs.) , Dish Wash Bar , Dish Wash Liquid , Door Mat , Drum Big. , Dry Mop , Dustbin Big (Round) , Dust Pan , Dove Soap , Dustbin (Square) , Electric Iron , Electric Kettle , Electric Switch 5 annual periodical maintenance , Electric Switch Board , Electrical Drill Machine , Exhaust Fan 12 , Extension Board 15 annual periodical maintenance - 4 Point , Fibre Board , First Aid Box With Medicine , Fiama Soap , Five Pin Socket 15Amp , Flask 1 Ltr. , Flexible Plastic Pipe , Flower Tub , Flower Vase , Food Container (10 Ltrs.) , Foot Ball , Full Jharu , G.I. Wire , Gainty , Garbage Bag , Garden Umbrella Synthetic , Garden Umbrella Synthetic , Glass Cover , Glass Set (Borrosil) , Goal Post Net , Hack Saw , Hallogen Complete Set - 1000 Wt , Hammar With Handle , Hand Sanitizer 100Ml , Hand Wiper , Hanger For T Flag , Hansua Iron (Big Size) , Harpic , Harpic , Hit Spray Black , Hit Spray Red , Hot Pot , Hot Pot , Hot Pot , Iron Shabol 6 , Jarican(White ) , Jhul Jharu , Jute Rope , Keeper Pad , Knife , L.E.D Decoration Light Chain , Ladder , Lecture Stand , Lime Dust , Liquid Hand Wash , Liquid For Wshing Machine , Lizol , Door Lock , M.C.B 64 annual periodical maintenance , Main Switch 64 annual periodical maintenance , Mask 3 Ply , Mask Cotton 3Ply , Mask N95 White , Mat Finish Sunmica , Mattress , Measuring Tape (100 Mtrs) , Mirror Glass 8Mm , Mirror With Frame (36X18) , Mosquito Destroyer Machine , Mosquito Destroyer Refill , Muritic Acid , Napthalin Ball , National Flag (6X4) , National Flag 3X4 , Notice Board , Nylon Rope , Odomos Cream , Odonil , Oxi- Meter , Paint 1Ltrs. , Paint 4 Ltrs , Paint Weather Coat , Pendent Holder , Phynyle , Pillow (White) , Pillow Cover , Plastic Bucket , Plastic Jug , Plastic Mosquito Net , Plastic Mug , Plastic Zipper Pkt , Ply Wood (12 Mm) , Ply Wood 18 Mm , Podium , Pressure Cooker , Primer (Iron) , Primer (Wooden) , Pumper , Pvc Mat , Pvc Door , R.O. Purifire , Road Carpet , Room Freshener , Round Neck T-Shirts , Sand Bags , Scissor , Scissor For Garden , Serving Bowl , Serving Spoon , Sheet Alluminium , Sickle , Skipping Rope , Small Towel , Small Duster , Socket Male - Female , Spade , Spoon (Medium) , Spoon (Small) , Sports Shoe , Spray Machine , Succession Board (5X3X1 ) , Table Cloth White , Table Flag National , Table Glass , Table Lamp , Tarpin Oil , Tea - Coaster , Tea Powder , Tea Vending Machine , Telephone Receiver (2 In 1) , Tissue Paper , Twist Mop , Twist Mob Refill , Toothpaste , Umbrella , Volley Bal Net , Volley Ball , Wall Cap Stand With Mirror Board. , Wall Clock , Wall Putty , Waste Basket , Water Bottle 500Ml , Water Bottle 250Ml , Weight Machine , White Colour T-Shirts , White Cotton Gloves , White Table Cloth , White Trouser , Wicket Keeping Gloves , Wickets , Wire Brush , Wire -Telephone , Plastic Box Big Size , Green Tea , Induction , Tug Of War Rope , Key Holder Box With Front Net Cover , 20 Ltr Water Drum , Celling Fan , Bag Loop Handel , Iron Grill , Water Heater (Gyeser) , Toilet Tissue , Half Pant , Pt Shoe , Ezee Wash 500G
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 14
West Bengal View Result →
2.
Health and Family Welfare #11180771 Price Bid
Tender For Supply Of Drugs And Medicines- 1 Drugs And Consumables 2 Oxygen (Medicinal Gas) Inhalation 3 Oxygen(Medicinal Gas) Inhalation Should Be Certified For Medical Use Contains Not Less Than 99% V/V Of Oxygen, Contains Not More Than 5Ppm V/V Of Carbanmonooxide, Contains Not More Then 30Ppm V/V Of Carban Dioxide Should Be Free Of Halogens, Oxidising Substances & Water. 4 Halothane Inhalation 250 Ml Bottle 5 Ketamine (As Hydrochloride) Injection 50 Mg /Ml,10 Ml Vial 6 Nitrous Oxide Inhalation 7 Thiopentone Injection Powder 0.5 G 8 Propofol Injection 1% Vial (10 Mg/Ml , 10 Ml Vial) 9 Isoflurane Inhalation 100 Ml Vial 10 Sevoflurane Inhalation 250 Ml 11 Bupivacaine Injection 0.5%, 5Ml Amp. 12 Bupivaccine Heavy 5 Mg With Dextrose Monohydrate 80 Mg/Ml Injection 4 Ml Ampoule 13 Lignocaine Injection 2%, 30 Ml Vial 14 Lignocaine Jelly 2% W/V ( With Seprate Nosal), 30Gm Tube 15 Lignocaine Hydrochloride And Adrenaline Bitartarate Injection 20Mg/Ml And 0.01Mg/Ml Adrenaline, 30 Ml Vial 16 Atropine Injection 0.6 Mg/Ml, 1 Ml Ampoule 17 Glycopyrolate Injection 0.2 Mg/Ml, 1 Ml Ampoule 18 Diazepam Injection 5 Mg/Ml, 2 Ml Ampoule 19 Diazepam Tablet 5 Mg 20 Midazolam Injection 1 Mg/Ml, 5 Ml Vial 21 Midazolam Nasal Spray 1.25 Mg/Spray 22 Diclofenac Supositories 50 Mg 23 Diclofenac Sodium Gastro-Resistant Tablet 50 Mg 24 Diclofenac (Sodium) Injection 25 Mg/Ml ,3Ml Amp. 25 Diclofenac Gel 1%, 30 Gm Tube 26 Diclofenac + Paracetamol Tablet 50Mg+325Mg 27 Ibuprofen Tablet 200Mg 28 Ibuprofen Tablet 400 Mg 29 Ibuprofen Suspension 100 Mg/5 Ml. 60 Ml Bottle 30 Paracetamol Tablet 500 Mg 31 Paracetamol Injection 150 Mg/Ml, 2 Ml Amp. 32 Paracetamol Peaditric 125Mg/5Ml 60 Ml Bottle 33 Paracetamol Paediatric Oral Suspension 150Mg/Ml, 10 Ml Vial With Marked Dropper 34 Paracetamol Infusion 100 Mg/10 Ml, 100 Ml Bottle Ffs Technology - 35 Aceclofenac Tablet 100 Mg 36 Etoricoxilb Tablet 90 Mg 37 Morphine Injection 10 Mg/Ml, 1 Ml Ampoule 38 Morphine Tablet 20 Mg 39 Tramadol Capsule 50 Mg 40 Tramadol Injection 50 Mg/Ml, 2 Ml Ampoule 41 Tramadol Hydrochloride Capsule 100 Mg 42 Pentazocine Injection 30 Mg/ Ml, 1 Ml Ampoule 43 Fentanyl Injection 50 Mcg/Ml, 2Ml Ampoule 44 Pethidine Injection 50 Mg/Ml, 1Ml Ampoule 45 Thiocolchicoside Capsule 4 Mg 46 Midazolam Nasal Spray 1.25 Mg/Spray 47 Beclofen Tablet 10 Mg Tablet 48 Allopurinol Tablet 100 Mg 49 Sulfasalazine Tablet 500 Mg 50 Methotrexate Tablet 2.5 Mg 51 Methotrexate Tablet 5 Mg 52 Naxproxen (500Mg)+ Domperidone (10Mg) Tablet 53 Diacerein 50 Mg + Glucosamine Sulphate 750 Mg Tablet - 54 Cetrizine Syrup 5 Mg/5Ml, 60 Ml 55 Chlorpheniramine Tablet 4 Mg 56 Pheniramine Maleate Injection 22.75 Mg/Ml, 2 Ml 57 Hydroxyzine Tablet 10 Mg 58 Dexamethasone Tablet 0.5 Mg 59 Dexamethasone Injection 4Mg/Ml, 2 Ml Ampoule 60 Hydrocortisone ( Sodium Sucinate Powder) Injection 100 Mg Vial, With 2 Ml Distilled Water For Reconstitution 61 Prednisolone Tablet 10 Mg 62 Prednisolone Tablet 20 Mg 63 Methyl Prednisolone Injection 1Gm, 1 Gm Vial With Diluent 64 Adrenaline Injection 1 Mg/Ml, 1:1000, 1 Ml Amp 65 Levocetrizine Tablet 5 Mg 66 Nor Adernaline Injection 4Mg/Ml 67 Cyproheptadine Tablet 4 Mg 68 Monteleukast Tablet 5 Mg 69 Methyl Prednisolone Tablet 8 Mg 70 Antisnake Venom ( Dry Powder For Polyvalent Solution) Injection Vial With 10 Ml Diluent 71 Calcium Gluconate Injection 100 Mg/Ml, 10 Ml Amp 72 Naloxone Injection 400 Mcg/Ml, 1Ml Ampoule 73 Pralidoxime (Pam) Injection 1 Gm Vial 74 Activated Charcoal Tablet 500 Mg 75 Carbamazepine Tablet 200 Mg 76 Carbamazepine Tablet 400 Mg 77 Carbamazepine Oral Solution 100Mg/5Ml, 30 Ml Bottle 78 Lorazepam Tablet 1 Mg 79 Lorazepam Tablet 2 Mg 80 Lorazepam Injection 4Mg, 2Ml 81 Magnesium Sulphate Injection 1 Gm /2Ml (50%W/V), 2 Ml Ampoule 82 Magnesium Sulphate Injection 2.5 Gm /5Ml(50%W/V), 5 Ml Ampoule 83 Phenobarbitone Tablet 30 Mg 84 Phenobarbitone Tablet 60 Mg 85 Phenobarbitone Injection 200 Mg/ Ml 86 Phenobarbitone Oral Solution 20 Mg/ 5 Ml,60 Ml Bottle 87 Phenytoin Tablet 100 Mg 88 Phenytoin Tablet 300 Mg 89 Phenytoin Oral Solution 25 Mg/Ml, 100 Ml Glass Bottle 90 Phenytoin (Sodium) Injection 100Mg, 2Ml Amp. 91 Sodium Valproate/Valproic Acid Enteric Coated Tablet 200 Mg 92 Sodium Valproate/Valproic Acid Enteric Coated Tablet 500 Mg 93 Sodium Valproate/Valproic Acid (Sodium)Controlled Released Tablet 300 Mg 94 Sodium Valproate Injection 100 Mg/Ml 95 Sodium Valproate Suspension 200 Mg/5 Ml, 100 Ml 96 Clobazam Capsule 10 Mg 97 Divalproex Sodium Tablet 500 Mg 98 Levetiracetam Tablet 500 Mg 99 Toperamate Tablet 50 Mg 100 Injection Levetricatum 100 Mg, 3 Ml - 101 Levitiracetam Oral Solution 102 Levitiracetam Oral Solution, 100Mg/Ml, 100Ml Bottle 103 Albendazole Chewable Tablet 400 Mg 104 Albendazole Oral Suspension 200 Mg/5 Ml,10 Ml Bottle 105 Levamasole Tablet 50 Mg 106 Levamasole Tablet 150 Mg 107 Amoxicillin Capsule 250 Mg 108 Amoxicillin Capsule 500 Mg 109 Amoxicillin Oral Suspension 125 Mg/5 Ml, 60 Ml Bottle 110 Amoxicillin + Pottasium Clavulanate Tablet 500 Mg + 125 Mg 111 Amoxicillin + Pottasium Clavulanate Dispersible Tablet 200 Mg +28.5 Mg 112 Amoxicillin + Clavulanic Acid Injection 1.2 Gm , 10 Ml Vial With Diluents 113 Amoxicillin + Clavulanic Acid Injection 250 Mg +50 Mg, Vial With Diluents 114 Ampicillin Sodium Injection 500Mg 2 Ml Vial With Diluent 115 Cefixime Tablet 200 Mg 116 Cefixime Oral Suspension 50 Mg/ 5 Ml, 30 Ml Bottle 117 Cefadroxil Oral Suspension 125 Mg/ 5Ml, 30 Ml Bottle 118 Cefotaxime Injection 250 Mg 119 Cefotaxime Injection 500 Mg 5 Ml Vial With Diluent 120 Cefotaxime Sodium Injection 1 Gm 10 Ml Vial With Diluent 121 Ceftriaxone Injection 250 Mg 2 Ml Vial With Diluent 122 Ceftriaxone Injection 1 G, 10 Ml Vial With Diluents 123 Benzathine Penicillin Injection Powder 12 Lacs Iu , Vial With Diluent 124 Cefoperazone + Sulbactam (1G+1G) Injection 125 Immipenum Injection 500 Mg 126 Imipenem And Cilastatin Injection (500 Mg+500 Mg) 127 Cefazolin Injection 1 Gm 128 Amikacin Injection 250Mg/ Ml, 2 Ml Vial 129 Amikacin Injection 50 Mg/ Ml, 2 Ml Vial 130 Gentamycin Injection 40 Mg/ Ml, 2 Ml Ampoule 131 Azithromycin Tablet 250 Mg 132 Azithromycin Tablet 500 Mg 133 Azithromycin Oral Suspension 40 Mg/Ml , 15 Ml Bottle 134 Levofloxacin Tablet 500 Mg 135 Ofloxacin Tablet 200 Mg 136 Ciprofloxacin Tablet 250 Mg 137 Ciprofloxacin Tablet 500 Mg 138 Ciprofloxacin Injection 2Mg/Ml, 100 Ml Bottle For Infusion Ffs Technology 139 Doxycycline Capsules 100 Mg 140 Cotrimoxazole (Sulfamethoxazole + Trimethoprim) Tablet 800 Mg + 160 Mg 141 Co-Trimoxazole [Sulphamethoxazole (A) + Trimethoprim (B)] Oral Liquid 200 Mg (A) + 40 Mg (B)/5 Ml 142 Metronidazole Tablet 200 Mg 143 Metronidazole Tablet 400 Mg 144 Metronidazole I.V Infusion 5 Mg/Ml, 100 Ml Bottle For Infusion (Ffs Technology) 145 Metronidazole Suspension 200Mg/5Ml , 60 Ml Bottle 146 Cloxacillin Capsule 500 Mg 147 Nitrofurantoin Capsule 100 Mg 148 Vancomycin Injection 500 Mg 149 Linezolid Tablet 600 Mg 150 Norfloxacin Tablet 400 Mg 151 Fluconazole Tablet 150Mg 10*10 152 Fluconazole Tablet 200 Mg 10*10 153 Griseofulvin Tablet 250 Mg 154 Itraconazole Capsules 200 Mg 155 Amphotericin B Powder For Injection 50 Mg And Vial Has Sodium Deoxychlolate Or Liposomal Complex 156 Terbinafine Tablet 250 Mg 157 Acyclovir Tablet 200 Mg 158 Acyclovir Tablet 400 Mg 159 Acyclovir Tablet 800 Mg 160 Tinidazole Tablet 500 Mg 161 Ivermectin Tablet 6 Mg 162 Diethyl Carbamazine Tablet 100Mg 163 Flunarazine Tablet 10 Mg 164 Propranolol Tablet (Sr) 40 Mg 165 Propranol Tablet 20 Mg 166 Levodopa + Carbidopa Tablet 100 Mg + 10 Mg 167 Trihexyphenidyl Tablet 2 Mg 168 Bromocriptine Tablet 2.5 Mg 169 Ferrous Sulpahte + Folic Acid Syrup 100 Mg + 0.5 Mg/ 5 Ml In A Flavoured Base/Vehicle 50 Ml Bottle, Ropp Cap Bottle With Inert Liner & Bottle To Be Provided With A Dispenser To Dispense To 1 Ml, 1.5Ml And 2 Ml Each Time And Packed In A Mono Carton Note:- For Detailed Specifications Kindly See Below Attached Copy. 170 Elemental Iron 60 Mg +Folic Acid 500 Mcg, Sugar Coated And Red Color Tablet 171 Ferrous (Iron Sucrose) Injection 20 Mg/Ml 172 Folic Acid Tablet 5Mg 173 Hydroxycobalamin Injection 1 Mg/ Ml 174 Warfarin (Sodium) Tablet 2 Mg 175 Heparin Injection 1% 176 Enoxaprin Sodium Injection 60 Mg In Pfs 177 Phytomenadion Injection 1 Mg/0.5 Ml Water Based Single Dose Ampoule 178 Plasma Volume Expander Injection ( Each 100 Ml Contains Polygeline, Polypeptides Of Degaraded Gelatin, Cross Linked Via Urea Bridges 3.5 G ( Equivalent To 0.63 G Of Nitrogen) Nacl Ip 0.85 G, Kcl Ip 0.038 G Cacl2 Ip 0.070G Water For Injection Ip Q.S Electrolytes In M.Mol/Litre, 500 Ml Ffs 179 Glyceryl Trinitrate (Sublingual) Tablet 500 Micrograms 180 Glyceryl Trinitrate ( Niroglycerine) Injection 5 Mg/Ml, 5 Ml Ampule 181 Isosorbide Mononitrate Tablet 30 Mg (Sr) 182 Isosorbide Dinitrate Tablet (Sublingual) 5 Mg 183 Metoprolol Tablet 25 Mg 184 Metoprolol Tablet (Sr) 50 Mg 185 Carvediolol Tablet 3.125 Mg 186 Adenosine Injection 3 Mg/ Ml, 1 Ml Ampoule 187 Diltiazem Injection 5 Mg/Ml 188 Diltizem Hydrochloride Tablet 30 Mg (Modified Release), 10*10 189 Amiodarone Tablet 100 Mg 190 Verapamil Tablet 40 Mg 191 Amiodarone Injection 150 Mg/ 3 Ml 192 Atenolol Tablet 50 Mg 193 Amlodipine Tablet 5 Mg 194 Amlodipine Tablet 10 Mg 195 Methyldopa Tablet 250 Mg 196 Methyldopa Tablet 500 Mg 197 Nifedipine Capsule(Sublingual) 5 Mg 198 Nifedipine Tablet Ip Sr/Er 10 Mg 199 Ramipril Tablet 5 Mg 200 Labetalol Tablet 100 Mg 201 Labetolol Injection 5Mg/Ml, 4Ml Amp. 202 Telmisartan Tablet 40 Mg 203 Telmisartan Tablet 80 Mg 204 Losartan + Hydrochlorothiazide Tablet (50 Mg + 12.5 Mg) 205 Olmesartan 20 Mg + Amlodipine 5 Mg + Hydrochlorothiazide 12.5 Tablet 206 Clinidipine Tablet 20 Mg 207 Hydrochlorthiazide Tablet 12.5 Mg 208 Chlorthalidone Tablet 6.25 Mg 209 Nebivalol Tablet 5 Mg 210 Enalapril Tablet 5 Mg 211 Dobutamine Injection 250Mg/5Ml 212 Dopamine Injection 40 Mg/ Ml In 5Ml Ampoule 213 Digoxin Tablet 0.25 Mg 214 Acetylsalicylic Acid Tablet 150 Mg 215 Acetylsalicylic Acid Tablet 75 Mg Gastro-Resistant (Enteric Coated/ Delayed Release) 216 Clopidogrel Tablet 75 Mg 217 Streptokinase Injection Powder 1500000 Iu 218 Atorvastatin Tablet 10 Mg 219 Atorvastatin Tablet 20 Mg 220 Rosuvastatin 10 Mg+ Fenofibrates 160 Mg Tablet 221 Tranexamic Acid Tablet 500 Mg 222 Tranexamic Acid Injection In Water For Injection 100 Mg/Ml, 5 Ml Ampoule 223 Mephentermine Injection 30 Mg/Ml, 1 Ml Amp. 224 Tranexamic Acid 500 Mg + Mefenamic Acid 250 Mg Tablet 225 Citicoline Tablet 500 Mg 226 Clotrimazole Pessaries 200 Mg 227 Clotrimazole Cream 2% W/W, 15 Gm 228 Clotrimazole Mouth Paint 1% W/V In Propylene Glycone Glycerian Base 15 Ml 229 Sertaconazole Cream 2% W/W, 15 Gm 230 Ketaconazole Lotion 2% W/V, 50 Ml 231 Acyclovir Eye Ointment 3% , 4.5 Gm Tube 232 Clindamycin Gel 1% W/W, 10Gm Tube 233 Clobetasol 0.05% + Gentamycin 0.1% Ointment 15 Gm Tube 234 Silver Sulfadiazine Cream 1%, 30 Gm Tube 235 Framycetin Cream 1%, 30 Gm Tube 236 Gentian Violet (Methylrosanilinium Chloride Paint Preparation Aqueous Solution 0.5%W/V), 50 Ml Dark Bottle 237 Benzoyl Per Oxide Gel 2.5%, 20 Gm Tube 238 Permethrin Lotion 5%, 50 Ml 239 Permethrin Cream 5%, 30 Gm 240 Betamethasone Dipropionate Cream 0.1% W/W , 5 Gm 241 Fluticasone Cream 0.01 % 10Gm 242 Calamine Lotion Ip-Calamine Ip-15% W/V, Zinc Oxide Ip-5%W/V,Glycerin Ip-5% W/V ,65Ml Bottle 243 Benzyl Benzoate 25% Lotion 100 Ml 244 Podophylline Resin Topical Solution 25% , 10 Ml Bottle 245 Fusidic Acid Cream 2%, 10Gm Tube 246 Coal Tar Solution 5% W/V, 100 Ml Bottle 247 Salicylic Acid Ointment 6%, 15 Gm Tube 248 White Petrolatum Jelly 100 %, 50 Gm Jar 249 Clotriamazole 1%+ Beclomethasone Dipropionate 0.025% Lotion 15 Ml 250 Mometasone Furoate Cream 0.1 % W/W 251 Mometasone Furoate Cream 0.1 % W/W, 10Gm Tube 252 Hydroquinone 2.0% W/W + Tretinoin 0.025% W/W + Mometasone Furoate 0.1% W/W In A Cream Base Q.S 253 Kojic Acid Cream 2 % 254 Hydroquinone 2%/4% + Tretinoin 0.025 % +Fluocinolone Skin Cream 255 Hydroquinone 4%+ Tretinoin 0.05% +Fluocinolone 0.01 % Skin Cream, 15Gm 256 Tacrolimus Ointment 0.03% W/W, 10 Gm 257 Tacrolimus Ointment 0.1% 10Gm Tube 258 Choline Salicylate Solution Bp Equivalent To Choline Salicylate 8.7 % W/W, Benzalkonium Chloride Solution Ip 0.01 % W/W, Lignocaine Hydrochloride Ip 2.0 % W/W Gel Base Q.S., 10 Ml Packing 259 Sunscreen Lotion Spf 26 ,100Ml Bottle 260 Clobetasone Butyrate(0.05 W/W + Miconazole(2.0 W/W) ,15 Gm Cream - 261 Halobetasol Propionate(0.5% W/W + Salicylic Acid (3% W/W) , 10Gm Ointment 262 Minoxidil Solution 5%, 60Ml Bottle 263 Gamma Benzene Hexachloride 1% Lotion,100 Ml 264 Sertaconazole Nitrate 2 % W/W+ Beclomethasone Dipropionate 0.025% W/W, 15Gm Tube 265 Cotrimazole 1%+ Beclomethasone Dipropionate 0.0025% Lotion 15 Ml Lotion 1%, 0.0025%, 15Ml 266 Mupirocin Cream 2% W/W,5Gm Tube 267 Isotretinoin Capsule 20 Mg 268 Methoxsalen Tablet 10 Mg 269 Triamcinolone Injection 20 Mg/ Ml 270 Triamcinolone Injection 40 Mg/Ml 271 Povidone Iodine Solution 5% ,500 Ml 272 Povidone Iodine Ointment 5%,15 Gm 273 Povidone Iodine Scrub (Povidone Iodine Cleansing Solution 7.5 %, W/V With Foaming Agent) 500 Ml 274 Povidine Iodine Scrub 7.5% W/V, 500Ml 275 Hydrogen Peroxide Solution 6%, 400 Ml Bottle 276 Cetrimide Solution 20% Conc. For Dilution, 500 Ml Plastic Bottle 277 Chlorhexidine Solution 5% Conc. For Dilution, 500 Ml 278 Bleaching Powder Containg Not Less Then 30% W/W Of Avialble Chlorine, 1Kg/25 Kg 279 Feracrylum 1% W/W Sterile Solution 100Ml Bottle 280 Feracrylum 3% W/W Gel , 15Gm Tube 281 Tritium Vulgare Extract And Phenoxyethanol Cream,32Gm Tube 282 Glutraldehyde Solution 2% - 2.5%, 1 Litre Pack 283 Potassium Permanganate Crystal For Solution 100 Gm 284 Bleaching Powder Containg Not Less Then 30% W/W Of Available Chlorine Powder - 285 Furosemide Tablet 40 Mg 286 Furosemide Injection 10 Mg/Ml, 2Ml Ampoule 287 Mannitol Intravenous Infusion 20% W/V, 100Ml Ffs Technology 288 Spironolactone Tablet 25 Mg 289 Torasemide Tablet 10 Mg 290 Tamsulosin 0.4 Mg + Dutasteride 0.5 Mg Tablet 291 Disodium Hydrogen Citrate Oral Solution/Syrup 1.38 -1.45 Gm/ 5 Ml, 100 Ml Bottle 292 Sodium Bicarbonate Infusion 7.5% W/V, 10 Ml Ampoule 293 Alkalizer Mb6 500Ml (Potassium Citrate Magnisum Citrate Syrup & Vit B6) 294 Bethanecholchloride Tablet 25 Mg 295 Darifenacin Tablet 7.5 Mg 296 Silodosin Tablet/Capsule 8.0 Mg 297 Mirabegron Tablet 50 Mg 298 Pyridium Tablet 200 Mg 299 Aluminium Hydroxide 240 Mg + Magnesium Hydroxide 100Mg+ Simethicone 25 Mg + Magnesium Carbonate 60 Mg Chewable Tablet 300 Dried Aluminium Hydroxide Gel + Magnesium Hydroxide + Simethicone Oral Suspension 250 Mg+ 250 Mg+ 50 Mg/ 5 Ml, 170 Ml Bottle 301 Ranitidine Injection 25 Mg/Ml, 2 Ml Amp 302 Ranitidine Syrup 150 Mg/10 Ml 303 Ranitidine Tablet 150 Mg, Film Coated 304 Omeprazole Capsule 20 Mg 305 Pantoprazole Injection 40 Mg, Vial With 10 Ml Diluent 306 Pantoprazole + Domperidone Sr (40Mg+30Mg) Capsule 307 Sucralfate 1Gm With Oxetacain 10Mg/10Ml Suspension 308 Simethicone Syrup 40Mg,60 Ml Bottle 309 Domperidone Tablet 10 Mg 310 Domperidone Suspension 1 Mg/Ml, 30 Ml Bottle 311 Cinnarizine Tablet 25 Mg 312 Metoclopramide Tablet 10 Mg 313 Metoclopramide Injection 5 Mg/Ml, 2 Ml Ampoule 314 Ondansetron Tablet 8 Mg 315 Ondansetron Injection 2Mg/Ml ,2Ml Ampoule 316 Ondansetron Oral Liquid 2 Mg/ 5 Ml 317 Ondansetron Oral Liquid 2Mg/5 Ml , 30 Ml Bottle 318 Promethazine Injection 25 Mg/Ml, 2 Ml Amp 319 Promethazine (Hydrochloride) Elixir Or Syrup 5 Mg/5 Ml, 60 Ml Bottle 320 Doxylamine Tablet 10 Mg 321 Prochlorperazine Mouth Dissolving Tablet Flavored Base 5Mg 322 Anti-Haemorrhoidal Containing: Beclomethasone Dipropionate 0.025% W/W, Phenylephrine Hyderochloride 0.10% W/W, Lignocaine Hydrochloride 2.5% W/W In Soft Paraffin Base 20 Gm Tube 323 Dicyclomine Tablet 10 Mg 324 Dicyclomine Oral Solution 10Mg/5Ml 325 Mephenamic Acid + Dicyclomine Tablet 500 Mg +20 Mg 326 Drotaverine Tablet 80 Mg 327 Drotaverine Injection 40 Mg/ 2 Ml 328 Hyoscine Butyl Bromide Tablet 10 Mg 329 Hyoscine Butyl Bromide Injection 20 Mg/ Ml, 1 Ml Amp. 330 Bisacodyl Gastro-Resistant (Enteric Coated/Delayed Release) Tablet 5 Mg 331 Lactulose Solution 10 Gm/ 15 Ml, 60 Ml Bottle 332 Ispaghula Granules/ Husk/ Powder 100 Gm 333 Enema 334 Dioctyl Sulfosuccinate Sodium Liquid,100 Ml 335 Magnesium Hydroxide Liquid 100 Ml 336 Oral Rehydration Salts Powder For 1000 Ml Solution 337 Oral Rehydration Salts Powder For 200 Ml Solution 338 Zinc (Sulphate) Dispersible Tablet 20 Mg 339 Octreotide Injection 100 Mcg/Ml, Single Dose 1 Ml Vial 340 Levosulpride (Sr) 75 Mg + Rabeprazole (Ec) 20 Mg Capsule 341 Saccharomyces Boulardii 5 Cfu Sachets 342 Probiotic Capsule/Syurp (Vizylac/Sporolac) 343 Probiotic Syrup (Streptococus Faecalis 30 Million, Clostridium Butirium 2 Million,Bacillius Mesentiricus 1 Million,Lactic Acid Bacillus 50 Million) Suspension In 5Ml 344 Probiotic Capsule (Lactobacillius Blends) 345 Chymotrypsin+ Trypsin (1:6 ) Tablet 100K Au 346 Cyproheptadine Hcl Ip-2Mg, Tricholine Citrate-275 Mg, Sorbitol Solution (70%)(Non Crystallising) Ip-2 Gm, 200 Ml Bottle 347 Erythropoietin Injection 4000 Units/Ml, Single Dose 1 Ml Vial 348 Insulin (Soluble) Injection 40 Iu/Ml In 10 Ml Vial 349 Intermediate-Acting Insulin (Nph) Injection 40 Iu/Ml In 10 Ml Vial 350 Biphasic Isophane Injection 40 I.U/Ml, (30/70), 10 Ml Vial 351 Lantus Insulin (Insulin Glargine 100 Units/Ml) 352 Metformin Tablet 500 Mg 353 Metformin Tablet 1 Gm 354 Metformin Tablet Sr 500Mg 355 Metformin Tablet Sr 1 Gm 356 Glimipride Tablet 1 Mg 357 Glimipride Tablet 2 Mg 358 Teneligliptin Film Coated Tablet 20 Mg 359 Voglibose 0.3 Mg + Metformin 500Mg+ Glimipride 1 Mg Tablet 360 Vildagliptin Tablet 50 Mg 361 Empagliflozin Tablet 10 Mg 362 Glibenclamide Tablet 5 Mg 363 Clomifene Citrate Tablet 50 Mg 364 Medroxyprogesterone Tablet 10 Mg 365 Norethisterone Tablet 5 Mg 366 Micronized Progesterone Tablet 200 Mg 367 Mifepristone Tablet 200 Mg 368 Mifepristone Tablet 25 Mg 369 Cabergoline Tablet 0.5 Mg 370 Dienogest Tablet 2 Mg 371 α -Hydroxyprogesterone Injection 500 Mg 372 Hcg 5000 Iu(Human Chorionic Gonadotropin) Injection 373 Conjugated Estrogen Tablet 0.625 Mg 374 Ethamsylate Tablet 500 Mg Tablet - 375 Latrazole Tablet 2.5 Mg 376 Thyroxine Tablet 50 Mcg 377 Carbimazole Tablet 5 Mg 378 Ethinyestradiol Tablet 5 Mcg 379 Estrogens Cream 0.625 Mg 380 Ethinylestradiol Tablet (0.03 Mg+ Levonorgestrel (0.15) Tablet 0.03Mg, 0.15 381 Copper Bearing Intra-Uterine Device Iucd 380 A & Iucd 375 - 382 Male Condom - 383 Non Harmonal Ormeloxifene 30Mg Tablet 384 Emergency Contraceptive Pill Levonorgestrel Tablet 1.5 Mg 385 Pregency Testing Kit - 386 Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 150 Mcg/Vial 387 Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 300Mcg/Vial 388 Injection Recombinant Anti-D Immunoglobulin 300Mcg Vial/Pfs 389 Anti Rabies Immunoglobulin Injection (Human) 150 Iu/Ml, 2Ml Vial 390 Hepatitis B Immunoglobulin Injection 1Ml. 391 Hepatitis B Immunoglobulin Injection 100 Iu, 1 Ml Vial - 392 Tetanus Toxoid Injection 0.5 Ml Ampoule 393 Rabies Vaccine Single Dose Rabies Vaccine 2.5 Iu Injection For Human Use Prepared In Chick Embryo/ Vero Cell/ Human Diploid Culture Single Dose With Diluent And Disposable Syringe With Needle 394 Decaravimab+ Miromavimab Injection (600 Iu) 3 Ml 395 Atracurium Besylate Injection 10 Mg/ Ml, 2.5 Ml Amp. 396 Succinyl Choline Injection 50Mg/Ml, 10Ml Vial 397 Neostigmine Injection 500 Mcg/ Ml, 5 Ml Ampoule 398 Vecuronium Injection 10 Mg Vial 399 Ciprofloxacin Eye Drops 0.3%, 10 Ml Plastic Bottle 400 Ciprofloxacin Opthalmic Ointment 0.3 % 5 Gm Tube 401 Tobramycin Opthalmic Solution 0.3% W/V, 5Ml 402 Natamycin Eye Drops 2%, 5 Ml 403 Acylovir Eye Oint 5%,5 Gm 404 Povidone Iodine 5% Eye Drops 405 Prednisolone Sodium Phosphate Eye Drops 1%, 5 Ml 406 Flurbiprofen Eye Drops 0.03%, 10 Ml Vial 407 Flouromethalone Eye Drops 0.1 % W/V,5 Ml Vial 408 Olopatadine 0.1% Eye Drops 5 Ml 409 Acetazolamide Tablet 250 Mg 410 Timolol Eye Drops 0.5%, 5Ml 411 Atropine Drops 1% 412 Homatropine Eye Drops 1% 413 Tropicamide + Phenylepherine Eye Drops 0.8% + 5%, 5 Ml Vial 414 Cyclopentolate Eye Drops 1% W/V 415 Sodium Carboxymethyl Cellulose Eye Drops 0.5% W/V, 10 Ml 416 Hydroxypropyl Methylcellulose Injection 2% , 3 Ml Pfs (Glass Syringe) 417 Hyaluronidase Injection 1500 Iu/Ml 418 Tryptan Blue Dye 0.06% W/V, 1 Ml Vial 419 Moxifloxacin Eye Drops 0.5% W/V ,5Ml 420 Ranibizumab Injection 10Mg/Ml 421 Travoprost 40 Mg/Ml 2.5Ml Vial Eye Drop 422 Xylometazoline Nasal Drops 0.05 %, 10 Ml 423 Xylometazoline Nasal Drops 0.1 %, 10 Ml 424 Saline Nasal Drops 0.65%, 10 Ml 425 Wax Dissolving Ear Drops (Paradichlorbenzene 2% W/V, Benzocain 2.7 % W/V, Chlorbutol 5% W/V, Turpentine Oil 15% Ear Drops ), 10 Ml 426 Clotrimazole 1% W/V + Lignocaine Hydrochloride 2% W/V Ear Drops, 5Ml Bottle 427 Clotrimazole Ear Drops 5 Ml Vial 428 Ichthoimol Glycerine Solution 10 Ml Vial 429 Ciprofloxacin(0.3%)+Dexametasone(0.1%) Ear Drops ,5Ml 430 Antibacterial & Anti Fungal Ear Drop (Beclomethasone 0.025% W/V +Chloramphenicol 5% W/V +Clotrimazole 1% W/V ,Glycerine Base), 10 Ml Ear Drops 431 Fluticasone Furoate Nasal Spray 432 Fluticasone Furoate Nasal Spray 27.5Mcg, 10Ml 433 Boro-Spirit Ear Drops,3% W/V Ear Drops 10 Ml 434 Methyl Ergometrine Tablet 125 Mcg 435 Methyl Ergometrine Injection 200 Mcg In 1 Ml Ampoule 436 Oxytocin Injection 5 Iu In 1 Ml Ampoule 437 Carboprost Injection 250 Mcg In 1 Ml Amp./ Vial 438 Misoprostol Tablet 200 Mcg 439 Misoprostol Tablet 25 Mg 440 Dinoprostone Gel 0.5 Mg, 3 Gm 441 Isoxsuprine Tablet 10 Mg 442 Isoxsuprine Injection 5 Mg/ Ml,2Ml Ampoule 443 Valethamate Injection 8 Mg/Ml 444 Betamethasone Injection 4Mg/Ml 445 Chlorpromazine (Hydrochloride) Tablet 100 Mg 446 Fluphenazine Injection 25 Mg, 1 Ml Ampoule 447 Haloperidol Tablet 5 Mg 448 Haloperidol Injection 5Mg/1 Ml, 1 Ml Amp 449 Haloperidol Injection Long Acting 50 Mg 450 Risperidone Tablet 2 Mg 451 Risperidone Tablet 4 Mg 452 Risperidone Injection Long Acting 25 Mg 453 Quetiapine Tablet 50 Mg 454 Quetiapine Tablet Sr 100 Mg 455 Aripipralzole Tablet 10 Mg 456 Aripiprazole Tablet 15 Mg 457 Aripiprazole Tablet 5 Mg 458 Olanzapine Tablet 20 Mg 459 Olanzapine Tablet 10 Mg 460 Olanzapine Injection 405 Mg 461 Olanzapine Injection 10 Mg 462 Olanzapine Injection 210 Mg Long Acting 463 Olanzapine Injection 300 Mg Long Acting 464 Clozapine Tablet 100 Mg 465 Clozapine Tablet 50 Mg 466 Amitriptyline Tablet 10 Mg 467 Amitriptyline Tablet 25 Mg 468 Fluoxetine Capsule 20 Mg 469 Imipramine Tablet 25 Mg 470 Sertraline Tablet (Sr) 50 Mg 471 Sertraline Tablet 100 Mg 472 Escitalopram Tablet 10 Mg 473 Paroxetine (Cr) Tablet 25 Mg 474 Paroxetine Tablet (Cr) 12.5 Mg 475 Capsule Venalafaxine Extended Release 37.5 Mg 476 Capsule Venalafaxine Extended Release 75 Mg 477 Gabapentin + Nortriptyline (400/10Mg) Tablet 478 Mirtazapine Tablet 15 Mg 479 Dothiepin Tablet 25 Mg 480 Lithium Carbonate Tablet 300 Mg 481 Lithium Tablet 400 Mg Sr 482 Alprazolam Tablet 0.25 Mg 483 Alprazolam Tablet 0.5 Mg 484 Donepezil Tablet 5 Mg 485 Donepezil Tablet 10 Mg 486 Clonazepam Tablet 0.5 Mg 487 Clonazepam Tablet 1 Mg 488 Donepezil Injection 10 Mg 489 Etizolam Tablet 0.50 Mg 490 Duloxetine Tablet 30 Mg 491 Bupropion Tablet 150 Mg 492 Buprinorphine Tablet 2 Mg 493 Buprinorphine Tablet 0.4 Mg 494 Disulfiram Tablet 250 Mg 495 Disulfiram Tablet 500 Mg 496 Nicotin Chewgum 2 Mg 497 Nicotin Chewgum 4 Mg 498 Naltrexone Tablet 50 Mg 499 Amisulpride Tablet 50 Mg 500 Pregablin 75Mg +Methylcobalmin 1500Mg +Nortriptylline 10Mg 501 Methylphenidate Tablet 5 Mg 502 Memantine Tablet 5 Mg 503 Tranylcypromine Tablet 5 Mg 504 Desvenlafaxine Tablet 50 Mg 505 Buprenorphine Transdermal Patch 10 Mcg/Hour 506 Buprenorphine Transdermal Patch 20 Mcg/Hour 507 Lacosamide Tablet 100 Mg 508 Blonanserin Tablet 4 Mg 509 Breviteracetam Tablet 50 Mg 510 Eeg Paste 511 Agomelatine Tablet 25 Mg 512 Vortioxetine Tablet 10 Mg 513 Melatonin Tablet 3 Mg 514 Tadalafil 10 Mg 515 Perampenel 2 Mg 516 Fluvoxamine 150 Mg 517 Ursodeoxycholic Acid Tablet 300 Mg 518 Cariprazine Tablet 1.5 Mg 519 Atomoxitine Capsule 10 Mg 520 Betahistine Tablet 8 Mg 521 Lamotrigine Tablet 25 Mg 522 Salbutamol Tablet 4 Mg 523 Salbutamol Syrup 2 Mg/5 Ml, 100 Ml Bottle 524 Salbutamol Inhaler Areosol 100 Microgram/ Dose, Mdi, Single Packing 525 Salbutamol Nebulizer /Respirator Sol. 2.5Mg, 2.5Ml Respule 526 Etophylline + Theophylline Tablet 231 Mg + 69 Mg (Sr) 527 Etophylline + Theophylline Injection 169.4 Mg + 50.6 Mg/2 Ml Ampoule 528 Budesonide Inhalation 200 Mcg/Dose, 200 Mdi/Dpi 529 Budesonide Nasal Spray 100 Mcg/Dose, Single Unit 530 Budesonide Respirator Solution For Use In Nebulizer 1 Mg, 2Ml Respule 531 Ipratropium Respirator Solution For Use In Nebulizer 250Mcg/ 1Ml, 2 Ml Respule 532 Cough Expectorent (Salbutamol+Bromhexine ) Syrup 2 Mg +4 Mg 533 Aminophylline Injection 25 Mg/ Ml, 10 Ml Ampoule 534 Budesonide + Formoterol Inhalation (200 Mcg + 6 Mcg), 120 Mdi 535 Cough Syrup Diphehydramine 14.08 Mg + Ammonium Chloride 138 Mg + Sodium Citrate 57.03Mg + Menthol Ip 1.14 Mg/5 Ml, 100 Ml Bottle 110 Ml Bottle 536 Cough Syrup Diphehydramine 14.08 Mg + Ammonium Chloride 138 Mg + Sodium Citrate 57.03Mg + Menthol Ip 1.14 Mg/5 Ml, 100 Ml Bottle - 537 Cough Syrup Ambroxol 15 Mg+ Terbutaline Sulphate 1.25 Mg+ Guaiphenesin 50 Mg+ Menthol 2.5 Mg, 100 Ml Bottle 538 Doxofylline Tablet 400 Mg 539 Dextromethorphan (15Mg/5Ml)+Chlorpheniramine Maleate (2Mg/5Ml) +Phenylephrine Hcl (5Mg/Ml) Oral Syrup, 100 Ml Bottle 540 Caffeine Citrate Injection 20 Mg/Ml (Equivalent To 10 Mg Caffeine Base/Ml) 541 Caffeine Citrate Oral Solution 20 Mg/Ml,3Ml 542 Clarithromycin Tablet 500 Mg 543 N- Acetylcysteine Tablet 600 Mg 544 Glycopyrronium 25 Mcg + Formoterol Fumarate 12 Mcg Rota Caps 545 Oral Glucose 75 Gm 546 Dextrose Intravenous Infusion Ip 5 % W/V , 500 Ml Ffs Bottle 547 Dextrose Intravenus Infusion Ip 10% W/V, 500 Ml Ffs Bottle 548 Dextrose Intravenous Infusion Ip 25% W/V, 100 Ml Ffs Bottle 549 Dextrose 5 % W/V With Sodium Chloride 0.9% W/V For Intravenous Infusion 500 Ml Ffs Bottle 550 Multi Electrolyte Injection (Isolyte P Multiple Electrolyte & Dextrose Injection Type 1 ), 500 Ml Ffs Bottle 551 Potassium Chloride Oral Solution 10%, 100 Ml Bottle 552 Potassium Chloride (Solution) Injectable 15% (150Mg/Ml) , 10 Ml Amp. 553 Ringer Lactate (Solution ) For Injection ( Compound Sodium Lactate) 500 Ml Ffs Bottle 554 Normal Saline (Sodium Chloride) Injection Solution 0.9% Isotonic, 100Ml 555 Normal Saline Injection 3% 556 Normal Saline (Sodium Chloride) Injection 0.9% W/V, 500 Ml Bottle ( Ffs Technology) 557 Water For Injection 5Ml Ampoule 558 Injection Human Albumin 5% Infusion Solution 5% 559 Injection Human Albumin 20% Infusion Solution 20 560 Ascorbic Acid Tablet 500 Mg 561 Pyridoxine Tablet 10 Mg 562 Pyridoxine Tablet 100 Mg 563 Vitamin A Oral Solution 100000 Iu/Ml, 100 Ml 564 B-Complex Tablet 565 Vitamin D3 Drops 400 Iu/Ml 566 Vitamin D3 Tablet (Chewable) 60000Iu 567 Calcium Salts 500 Mg+ Vitamin D3 250 Iu Tablet 568 Thiamine Injection 100 Mg/Ml, 2 Ml Vial 569 Calcium Phosphate Suspension/Syrup:- Each 5Ml Contains: Vit D3 (Cholecatciferol) Ip-200Iu Vitamin B12 (Cyanocobalamin) Ip 2.5Mcg, Calcium- 82Mg (As A Mixture Of Calcium Phosphats Calculated As 0.12G Ca3 (Po4) 2 Suspension/Flavoured Syrupy Base- Q.S. 200Ml Bottle. 570 \Hematinic With Amino Acids Vitamin And Zinc Syrup 200 Ml Bottle, Each 10 Ml Contains: Ferrous Glycine Sulphate-216.50Mg, L-Histidine Hcl-25.0 Mg, Pyridoxine Hydrochloride Ip-1.5 Mg, Nicotinamide Ip-25.0 Mg, Folic Acid Ip-0.5 Mg, Cyanocobalamin Ip-2.5 Mcg, Zinc Ascorbate 50 Mg, Approved Colors Used\ 571 Multi Vitamin Infusion 10 Ml: Each Ml Contains Vitamin A (As Vitamin A Concentrate Oily Form) Lp 1100 Lu, Cholecalciferol Lp 100 Lu, Tocopheryl Acetate Lp 0.5Mg, Nicotinamide Lp 10Mg, Riboflavin Sodium Phosphate Lp 1.4Mg, Pyridoxine Hydrochloride Lp 1.65Mg, Thiamine Hydrochloride Lp 5.0Mg, Ascorbic Acid Ip 50.0Mg, L-Cysteine Hydrochloride Usp 0.2Mg, Benzyl Alcohol (As Preservative) Lp 1.0% V/V, Water For Injections Lp Q.S 572 Methylcobalamin Tablet 1500 Mcg 573 Pregabalin 75 Mg+ Methylcobalamin 1500 Mcg Tablet 574 Alfacalcidol Soft Gelatin Capsule 0.25 Mcg 575 Biotin Tablet 10 Mg 576 Thiamine Tablet 100 Mg 577 10 Essential Amino Acid With Vitamins And Minerals Capsules (10X10) 578 Amino Acid Iv Infusion Minimum 10 Essential Amino Acids, 250Ml Bottle - 579 Artesunate Injection 60 Mg/Ml 580 Chloroquine Phosphate Injection 40 Mg/Ml 581 Chloroquine Phosphate Tablet 250 Mg, Equivalent To 155 Mg Chloroquine Base 582 Chloroquine Phosphate Oral Solution 50 Mg/ 5 Ml, 50 Ml Bottle 583 Primaquine Tablet 2.5 Mg 584 Primaquine Tablet 7.5 Mg 585 Primaquine Tablet 15 Mg 586 Quinine Sulphate Tablet 300 Mg 587 Quinine Dihydrochloride Injection 300 Mg/Ml, 2 Ml Ampoule 588 Sulfadoxine + Pyrimethamine Tablet 500 Mg + 25 Mg 589 Temphos 50% Ec 5 Liter Pack 590 Malathion Technical 95%, 250 Kg 591 Deltamethrin 2.5% Wp, 25 Kg 592 Cyphenothrin 5% Ecs (Insecticide/Adulticide For Fogging) 593 Bivalent Antigen Based Rapid Diagnostic Kit For Malaria 594 Pyrethrum Extract 2% 595 Dengue Ns1 Antigen Elisa Based Test Kit,96 Test/Kit - 596 Mac Elisa Igm Dengue Kit 597 Sofosbuvir 400 Mg Tablet + Ledipasvir 90 Mg Tablet 598 Sofosbuvir 400 Mg Tablet 599 Daclatasvir 60 Mg Tablet 600 Daclatasvir 30 Mg Tablet 601 Entecavir 1 Mg Tablet 602 Entecavir 0 .5 Mg Tablet 603 Ribavirin Capsules 200 Mg 604 Tenofovir Tablet 300 Mg 605 Sofosbuvir 400Mg+ Velpatasvir 100 Mg Tablet 606 Rtpcr Kits For Quantitative Viral Load Test For Hepatitis B Virus 607 Rtpcr Kits For Quantitative Viral Load Test For Hepatitis C Virus 608 Storage Vial 5 Ml 609 Racked Filter Pipette Micro-Tips(Sterile) 10 Ul 610 Racked Filter Pipette Micro-Tips(Sterile) 20 Ul 611 Racked Filter Pipette Micro-Tips(Sterile) 1000 Ul 612 Racked Filter Pipette Micro-Tips(Sterile) 200 Ul 613 Filter Pipette Micro-Tips (Sterile) 10 Ul 614 Filter Pipette Micro-Tips (Sterile) 20 Ul 615 Filter Pipette Tips (Sterile) 100 Ul 616 Filter Pipette Tips (Sterile) 200 Ul 617 Filter Pipette Tips (Sterile) 1000 Ul 618 Ethanol Imported (20 Bottles Per Bottle) 5 Liter Pack 619 Molecular Biology Grade Water As Per Requirement 620 Screw Capped Storage Vial 2Ml (500 Vials) Per Pack 2 Ml 621 100 Well Micro Tube Storage Box 622 Para Film 623 Blue Nitrile Gloves 624 Single Channel Variable Volume Micropipette 0.5-10 Ul 625 Single Channel Variable Volume Micropipette 02-20 Ul 626 Single Channel Variable Volume Micropipette 05-50 Ul 627 Single Channel Variable Volume Micropipette 10-100 Ul 628 Single Channel Variable Volume Micropipette 20-200 Ul 629 Single Channel Variable Volume Micropipette 100-1000 Ul 630 96 Well Qper Plates With Adhesive Optical Scaling Membrane 631 Individual Pcr Tubes 8-Tube Strips(Clear) 632 Optical Flat 8-Cap Strips 0.2Ml Tube Strips 633 8 Channel Variable Value Micropipette 2-20 Ul 634 Micro Centrifuge Tubes Mctival (Sterile) 2 Ml 635 96 Well Reversible Rack F 0.5 To 2.0Ml Vials 636 Rnase And Dnase Degradation Solution 637 Rnase And Dnase Degradation Solution Wipes 638 Dna Blood Extraction Kit 639 Viral Rna Extraction Kit 640 Purified Freeze €“ Dried Human Coagulation Factor Viii, Virus Inactivated Injection 250 Iu 641 Anti Hemophillic Factor Ix Vial Injection Size 500 Iu 642 Anti Hemophillic Factor Vii Injection 1Mg,Vial/Ampoule 643 Anti Hemophillic Factor Vii Injection 2Mg,Vial/Ampole 644 Anti Hemophillic Factor Viii Inhibitor Bypassing Agent Injection 500 Iu,Vial/Ampoule 645 Anti Hemophillic Factor Viii Inhibitor Bypassing Agent Injection 1000 Iu,Vial/Ampoule 646 Recombinant Anti Haemophilic Factor Viii (Rf Viii)Standard Half Life Injection 250 Iu 647 Recombinant Anti Haemophilic Factor Viii (Rf Viii)Extended Half Life Injection 500 Iu 648 Recombinant Anti Haemophilic Factor Ix(Rf Ix )Standard Half Life Injection 250 Iu 649 Recombinant Anti Haemophilic Factor Ix (Rf Ix)Extended Half Life 500 Iu 650 Emicizumab-Kxwh Injection 30 Mg/Ml 651 Emicizumab-Kxwh Injection 60 Mg/0.4 Ml 652 Anti Haemophilic Factor Ix Vial Injection 600Iu 653 Leuco Reduction Filter Bed Side For Packed Red Blood Cells - 654 Sanitary Napkin 655 Weekly Iron Folic Acid Tablet Each Tablet Containing 60 Mg Elemental Iron+500 Mcg Folic Acid, Sugar Coated ,Blue Colour 656 Iron And Folic Acid Tablet ( Wifs Junior ) Containing Dried Ferrous Sulphate Ip Equivalent To Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet. Tablet Are Sugar Coated And Pink Coloured Tablets With Only Edible Colours Used Tablet Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet 657 Salt Testing Kit 658 Oseltamivir Tablet 75 Mg 659 Oseltamivir Tablet 45 Mg 660 Oseltamivir Tablet 30 Mg 661 Oseltamivir Syrup (Each 1 Ml Reconstituted Suspension Contain 12 Mg Oseltamivir, 75 Ml Bottle) Syrup 662 Seasonal Influenza Quadrivalent/ Tetravalent Vaccine 663 Deferiprone Tablet 500 Mg 664 Deferasirox Tablet 500 Mg 665 Desferrioxamine Injection 500 Mg 666 Medroxyprogesterone Acetate Injection Ip (Dmpa ) 25 X 1X 1Ml (Contraceptive Injection For Im Use Only) 667 Single Blood Bags 350 Ml 668 Double Blood Bags 350 Ml 669 Triple Blood Bags 450 Ml 670 Quadruple Blood Bags 450 Ml 671 Double Blood Bag 450 Ml 672 Triple Blood Bags 350 Ml 673 Triple Blood Bag With Sagm 350 Ml 674 Triple Blood Bag With Sagm 450 Ml 675 Quadruple Blood Bag With Sagm 350 Ml 676 Quadruple Blood Bag With Sagm 450 Ml 677 Hiv Elisa (96 Test Each) 678 Hbsag Elisa (96 Test Each) 679 Hcv Elisa (96 Test Each) 680 Hiv Rapid (30 Test Each) 681 Hbsag Rapid (30 Test Each) 682 Hcv Rapid (30 Test Each) 683 Rpr/Vdrl (50 Test Each) 684 Reagents Anti-A, Anti-B, Anti-D Sera 685 Reagents Anti-Ab Serum 686 Reagents Antihuman Globulin Serum 687 Reagents Anti-A1 (Lectin) Serum 688 Reagents Bovine Albumin 22% 689 Aprepitant 80Mg (Kit Contains 3 Caps) 690 Aprepitant Kit 120 Mg 691 Bleomycin Injection 15 Mg, 15 Mg/Ml Vial 692 Capecitabine Tablet 500 Mg 693 Capecitabine Tablet 1000 Mg 694 Carboplatin Injection 150 Mg, 10 Mg/Ml Vial 695 Carboplatin Injection 450 Mg, 10Mg/Ml Vial 696 Cisplatin Injection 50 Mg, 1 Mg/Ml Vial 697 Cisplatin Injection 10 Mg 698 Cyclophosphamide Injection 1000Mg, 1.33Mg/Ml Vial 699 Cyclophosphamide Injection 500Mg, 10Mg/Ml Vial 700 Cyclophosphamide Tablet 50 Mg 701 Dacarbazine Injection 200 Mg, 10Mg/Ml Vial 702 Dacarbazine Injection 500 Mg 703 Docitaxel Injection 120 Mg, 20Mg/ 0.5 Ml Vial 704 Doxorubicin (Hydrochloride Powder) Aqueous Solution 10Mg/2Ml 705 Doxorubicin (Hydrochloride Powder) Aqueous Solution 50 Mg/ 2 Ml Vial 706 Epirubicin Injection 50 Mg, 2Mg/Ml Vial 707 Epirubicin Injection 10 Mg, 2Mg/Ml Vial 708 Etoposide Injection 100Mg, 20Mg/Ml Vial 709 Etoposide Capsule 50 Mg 710 5-Fluorouracil Injection 500Mg, 50Mg/Ml Ampules 711 Fluorouracil Injection 1 Mg 712 Filgrastim Injection 300Mcg, 300Mcg/0.5 Ml Prefilled Syringe 713 Peg Filgrastim Injection 6 Mg 714 Geftinib Tablet 250 Mg 715 Gemcitabine Injection 200Mg, 100Mg/Ml Vial 716 Gemcitabine Injection 1000Mg, 10Mg/Ml Vial 717 Imatinib Tablet 400 Mg 718 Isophosphamide Injection 200Mg, 100Mg/Ml Vial 719 Lenalidomide Tablet 10 Mg 720 Letrozole Tablet 2.5 Mg 721 Oxaliplatin Injection 50Mg, 5Mg/Ml Vial 722 Oxaliplatin Injection 100Mg, 5Mg/Ml Vial 723 Paclitaxel Injection 260Mg, 10Mg/1.67 Ml Vial 724 Pemetrexate Injection 500Mg, 25Mg/Ml Vial 725 Tamoxifen Citrate Tablet 20 Mg 726 Tamoxifen Citrate Tablet 10 Mg 727 Vinblastine Injection 10 Mg, 1Mg/Ml Vial 728 Vincristine Injection 1 Mg, 1Mg/Ml Vial 729 Ateplase Injection 20 Mg 730 Ateplase Injection 50 Mg 731 Tenecteplase Injection 20 Mg 732 Rituximab Injection 500 Mg 733 Methotrexate Injection 50 Mg 734 Methotrexate Tablet 50 Mg 735 Zolidronic Acid Injection 4 Mg 736 Actinomycin Injection 0.5 Mg 737 Goserline Injection 10.8 Mg 738 Luperolide Injection 22.5 Mg 739 Degaralix Injection 240 Mg 740 Thalidomide Tablet 100 Mg 741 Exemestene Tablet 1 Mg 742 Sunitinib Tablet 50 Mg 743 Pazopanib Tablet 200 Mg 744 Dexamethasone Tablet 4 Mg 745 Dexamethasone Tablet 8 Mg 746 Erlotinib Tablet 100 Mg 747 Morphine Tablet 10 Mg 748 Morphine Tablet 30 Mg Sr 749 Buprinorphine Patch 5 Mg 750 Buprinorphine Patch 10 Mg 751 Buprinorphine Patch 15 Mg 752 Iohexol Injection 300 Mg 753 Zoledronic Acid Injection 4 Mg 754 Trastuzumab Injection 150 Mg 755 Trastuzumab Injection 450 756 Onco Bcg Injection 757 Onco Bcg 80Mg Injection 758 Mitomycin Injection 40 Mg 759 Granisetron Injection 1 Mg 760 Leucovorin Injection 50 Mg 761 Bortezomib Injection 2 Mg 762 Ifosfamide Injection 1 Gm 763 Mesna Injection 400 Mg 764 Carfilzomib Injection 60 Mg 765 Bicalutamide Tablet 50 Mg 766 Sorafenib Tablet 200 Mg 767 Temozolamide Tablet 100 Mg 768 Temozolamide Tablet 250 Mg 769 Clindipine Tablet 10 Mg 770 Codon Set 771 Codon I/V Set Woth Air Vent & 0.2 Micron Filter 772 Granisetron Injection 3 Mg 773 Reteplase Injection 10.4 U(18.1 Mg) Kit 774 Meropenum Injection 125 Mg 775 Meropenum Injection 500 Mg 776 Piperacillin 1 Gm + Tazobactum 0.12Gm Injection 777 Piperacillin 4 Gm + Tazobactum 0.5Gm Injection,Vial Injection 4 Gm+ 0.5 Gm 778 Netilmycin Injection 25Mg/Ml 779 Ethamsylate Injection 250 Mg/2 Ml 780 Dns ( Sodium Chloride And Dextrose, Each 100 Ml Contains Dextrose 5 Gm, Nacl 0.9 G) 781 Calcium Syrup Each 5 Ml Contains Calcium 250Mg, Vitamin D3 125 Iu 782 Simyl Mct Oil (Medium Chain Triglycerides And Permitted Antioxidants (Tocopherol Accetate) 783 Ecg Electrodes (Neonate) 784 Umbilical Catheter No. 5, (5 Fr Length 37 Cm, -31Ml/Min Pvc 785 Umbilical Catheter No. 6 (6 Fr Length 37 Cm, -31Ml/Min Pvc 786 Oxygen Tubing, Suction Tubing (Different Colours) 787 Triway (Three Way Stop Clock) Lipid Resistant Pyrogen Free, Sterile, Latex Free 788 Bone Narrow Needle For Neonates 18 G 789 Blood Lancets For Glucometer 790 Grip Lock 791 Picc Line 24 G, 28 G 792 Suction Plain Catheter No. 6, Disposable Pyrogen Free 793 Suction Plain Catheter No. , 8 Disposable Pyrogen Free 794 Oxygen Hood For Neonates 795 T- Connector 796 Y- Connector For 8-10 Mm 797 Nasal Prongs Term & Preterm Single Patient Use With Twin Bore Nasal Pronges Sets, Extra Soft Medical Grade Nasal Tips 798 Nasal Prongs Preterm (Pead) 3.0 & 3.7 Mm - 799 Octopus Bi Connector (Length 1-10 Cm 1.5*2.5, 2-10 Cm 1.5*2.8)Pur Vol- 0.57 Ml 800 Q-Way 6 Inches ,Sterlized Using Ethylene Oxide 801 Tegaderm 2, 3/8 Inch*2.3/4 Inch 6*7 Cm Tegaderm Tm Films Iv Transparent Film Iv Transparent Film Dressing Style(Latex Free) 802 Uro Bag (Neonates)- 100 Ml 803 Dyna Plast Adhesive Tape ( 10 Cm Width, 5 Cm Length) 804 Surfactant- Survanta(Synthetic)(25 Mg/1Ml), Exosurf (Bovine) 805 Micro Drip Set 806 Transpore 2\ 807 Transpore 4\ 808 Chest Drain (Adults) 809 Disposable Needle 24 810 Anti Diptheria Serum 811 Td Vaccine 812 Erythromycin Tablet 250 Mg 813 Erythromycin Syrup 125 Mg/5 Ml, 60 Ml 814 Hepatitis B Vaccine (R Dna) I.P. 815 Urine Screening Through Dry Chemistry Rapid Testing Kit/Strips For Multiple Drug Uses:- 1. Morphine/ Opiates 2. Buprenorphine 3. Tramadol 4. D. Propoxyphene 5. Benzodiazepines Test Kit Kit 816 Nicotine Patches 817 1.Nicotine Patches 7Mg 2. Nicotine Patches 14Mg 818 Nicotine Pastilles 2 Mg 819 Nicotine Pastilles 4 Mg 820 Tablet Vareniciline 0.5Mg 821 Tablet Vareniciline 1 Mg 822 Tablet Buspirone 5 Mg 823 Anti Rabies Vaccine Through Id Route, 1 Ml Vials Vaccine 1Ml. 824 Tenofovir 300 Mg+ Lamivudine 300 Mg Tablet 825 Dolutegravir Tablet 50 Mg 826 Dual Kits For Hiv And Syphilis - 827 Levofloxacin Tablet 250 Mg 828 Pyridoxine Tablet 50 Mg 829 Moxifloxacin Tablet 400 Mg 830 Cbnaat Tb Cartridges - 831 Cbnaat-Xdr Cartriges 832 Ethambutol Tablet 100 Mg 833 Ethambutol Tablet 400 Mg 834 Ethambutol Tablet 800 Mg 835 Clofazimine Tablet 100 Mg 836 Clofazimine Tablet 50 Mg 837 Cycloserine Capsule 250Mg 838 Delamanid Tablet 50 Mg 839 Bedaquiline (Bpq) - L Tablet 840 Ethinamide Tablet 250 Mg 841 Isoniazid Tablet 100 Mg 842 Isoniazid Tablet 300 Mg 843 3 Hp Isoniazid Plus Rifapentine Fdc (300Mg/300Mg) Tablet 844 Rifapentine Tablet 150 Mg 845 Rifapentine Tablet 300 Mg 846 Rifampicin Tablet 150 Mg 847 Truenat Mtb Chips Test Kit 848 Truenat (Rip Chips) Test Kit - 849 Bbl Mgit Tubes For Use In Bactec Mgit 960 (7Ml) - 100 Tubes/Pkg Catalouge No 245122 850 Bactec Mgit 960 Supplement Kit (100 Tests, Panta And Oadc Combined) Catalogue No: 245124 Kit - 851 Bactec Mgit 960 Sire Kit. One Kit Is Sufficient For 40 Test Catalogue No: 245123 852 Genotype Mtbdr Si V2.0 96 Test 31796Am. Test Kits Composed Of 31796 A Genotype Mtbdr Si V2.0 - 853 Genotype Mtbdr Plus V2.0 30496 Am. Test Kits Composed Of 30496A Genotype Mtbdr Plus Version 2.0 And 51610 Genolyse - 854 Gt Blot 48 Reagent Kits 855 Genolyse 96 Test 51610 856 2Fdc (P) (H50 & R75) 857 3Fdc Cp (A) (H75, R150 & E275) 858 3Fdc (P) (H50, R75, Z150) 859 4Fdc (A) (H75, R150, Z400 & E275) 860 Tablet Ethambutol 100 Mg 100 Mg 861 Rifampicin Tablet 300 Mg 862 Genolyse 96 Test 51610 - 863 Early Childhood Development (Ecd) Kit For Ashas - 864 Absorbant Cotton Gauze, 90 Cm X 18 Mtrs, Is No: 758:2023, Specification Mentioned Under Mdr-2017 As Amended From Time To Time ( 1X 5 Than) 865 Cotton Bandage Cloth, 15 Cm X 5 Mtrs, Is No. 863:1988, Specification Mentioned Under Mdr-2017 As Amended Time To Time, (1 X12 Rolls) 866 Cotton Bandage Cloth, 10 Cm X 4 Mtrs, Is No. 863:1988, Specification Mentioned Under Mdr-2017 As Amended Time To Time, (1 X12 Rolls) 867 Cotton Bandage Cloth, 5 Cm X 4 Mtrs, Is No. 863:1988, Specification Mentioned Under Mdr-2017 As Amended Time To Time, (1 X12 Rolls) 868 Crape Bandages Bp(1 X 10 Rolls) 10 Cm X 4.5 Mtrs 869 Crape Bandages Bp(1 X 10 Rolls) 15 Cm X 4.5 Mtrs 870 Plaster Of Paris Bandages B.P. (1 X 10 Rolls) 10 Cm X 2.7 Mtrs, (High Strength) 871 Plaster Of Paris Bandages B.P (1 X 10 Rolls) 15 Cm X 2.7 Mtrs, (High Strength) 872 Cotton Wool Ip 100 Gm 873 Cotton Wool Ip 500 Gm 874 Orthopadding Cast/Zigzag Cotton Roll 4\ 875 Orthopadding Cast/Zigzag Cotton Roll 6\ 876 Disposable Syringes 2 Ml, (24G), Ribbon Pack 877 Disposable Syringes 5 Ml, (23G), Ribbon Pack, Reuse Preventable 878 Disposable Syringes 10 Ml. With Needle, Ribbon Pack 879 Disposable Syringes 2 Ml, (23G), Ribbon Pack 880 Disposable Syringes 1 Ml (23G), Ribbon Pack 881 Disposable Insulin Syringe (31G), Ribbon Pack 882 Disposable Syringe 20 Ml With Needle, Ribbon Pack 883 Disposable Syringe 50 Cc With Needle, Ribbon Pack 884 Disposable Syringes 2 Ml, (24G) Reuse Preventable 885 I.V. Canulas 24 With Luer Lock 886 I.V. Canulas 22 With Luer Lock 887 I.V. Canulas 20 With Luer Lock 888 I.V. Canulas 18 With Luer Lock 889 I.V. Canulas 16 With Luer Lock 890 I.V. Canulas 26 With Luer Lock 891 I.V.Sets Disposable With Air Vent 892 Blood Administration Set/Blood Transfusion Set. Transparent Cylindrical Drip Chamber With 200 Micron Filter. 150 Cm Long Smooth Kink Resistant Tubing. 893 Pedeatrics Iv Drip Set With Air Vent 894 Sterile Disposable Spinal Needle For Single Use 23G X 3 1/2 Inch 895 Sterile Disposable Spinal Needle For Single Use 25G X 3 1/2 Inch Clear/ Transparent Hub 896 Sterile Disposable Spinal Needle For Single Use 22 G X 3 1/2 Inch Clear/ Transparent Hub 897 Sterile Disposable Spinal Needle For Single Use 24 G X 3 1/2 Inch Clear/ Transparent Hub 898 Sterile Disposable Spinal Needle For Single Use 26 G X 3 1/2 Inch Clear/ Transparent Hub 899 Sterile Disposable Spinal Needle For Single Use 18 G X 3 1/2 Inch Clear/ Transparent Hub 900 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +17D 901 Endotracheal Tube, Cuffed No. 5.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 5.0Mm - 902 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +18D 903 Endotracheal Tube, Cuffed No. 6.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 6.0Mm - 904 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +19D 905 Endotracheal Tube, Cuffed No.6.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 6.5Mm - 906 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +20D 907 Endotracheal Tube, Cuffed No. 7.0 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 7.0Mm - 908 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +21D 909 Endotracheal Tube, Cuffed No. 7.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 7.5Mm - 910 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +22D 911 Endotracheal Tube, Uncuffed No. 4.5 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 4.5Mm - 912 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +23D 913 Endotracheal Tube, Uncuffed No. 2.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 2.5Mm - 914 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +24D 915 Endotracheal Tube, Uncuffed No. 3.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 3.0Mm - 916 Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +25D 917 Endotracheal Tube, Uncuffed No. 3.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 3.5Mm - 918 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +17D 919 Endotracheal Tube, Uncuffed No.4.0 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 4.0Mm - 920 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +18D 921 Endotracheal Tube, Uncuffed No. 5.0 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 5.0 Mm - 922 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +19D 923 Endotracheal Tube, Cuffed No. 5.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 5.5Mm - 924 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +20D 925 Endotracheal Tube, Cuffed No. 8.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 8.0Mm - 926 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +21D 927 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +22D 928 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +23D 929 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +24D 930 Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +25D 931 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +17D 932 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +18D 933 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +19D 934 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +20D 935 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +21D 936 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +22D 937 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +23D 938 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +24D 939 Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +25D 940 Infant Feeding Tube 4 941 Infant Feeding Tube 5 942 Infant Feeding Tube 7 943 Infant Feeding Tube 9 944 Infant Feeding Tube, Two Lateral Eyes At Distal End, Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa, With Female Flexible Mount With In-Built Closure, Radio Opaque Line, Sterile, Size: 6Fg 945 Infant Feeding Tube, Two Lateral Eyes At Distal End, Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa, With Female Flexible Mount With In-Built Closure, Radio Opaque Line, Sterile, Size: 8Fg 946 Infant Feeding Tube:Two Lateral Eyes At Distal End, Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa, With Female Flexible Mount With In-Built Closure, Radio Opaque Line, Sterile 10 Fg 947 Ryles Tube 8 948 Ryles Tube 10 949 Ryles Tube 12 950 Ryles Tube 14 951 RyleS Tube/ Nasogastric Tube (P.V.C) With Radio Opaque Lining. Size:16, Soft , Kink Resistant Pvc Tubing For Atraumatic Intubation, Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation, Four Lateral Eyes For Greater Efficiency, Radio Opaque Line, Marking At 50, 60, 70 Cm From Tip, Colour Coded Funnel, With Luer Connector/Closure, Length 105 Cm 952 Mucous Suction Trap 953 Foleys Catheter 8 954 Foleys Catheter 10 955 Foleys Catheter 12 956 Foleys Catheter 18 957 Foleys Ballon Catheter 2 Way ( Silicon Elastomer ) Non- Toxic Pyrogen Free Sterile For Single Use Only , Size 14, Single Sterile Packing 958 Foleys Ballon Catheter 2 Way ( Silicon Elastomer ) Non- Toxic Pyrogen Free Sterile For Single Use Only , Size 16, Single Sterile Packing 959 Urine Bag 2000 Ml, Single Unit Packing 960 Disposable Surgical Gloves No. 6.5, Isi Mark 961 Disposable Surgical Gloves No. 7, Isi Mark 962 Disposable Surgical Gloves No. 7.5, Isi Mark 963 Disposable Surgical Gloves No.6 , Isi Mark 964 Examination Gloves (Medium Size), Isi Mark 965 Micropore/Surgical Paper Tape 25Mm X 9.1Mtr. 966 Micropore/Surgical Paper Tape 50Mm X 9.1 Mtr. 967 Micropore/Surgical Paper Tape 75Mm X 9.1 Mtr. 968 Disposable Shoe Cover 969 Disposable Mask 970 Disposable Cap 971 Sterile Cord Clamp Non Toxic, Pyrogen Free Sterile For Single Use Only Single Unit Packing 972 Ecg Electrodes (Disposable Kit) Pack Of 6 973 Ot Sponges With Radio-Opaque Thread (With 8 Layers 30 Cm X 30 Cm ) 974 Carbolic Acid 400 Ml 975 Opsite Eye Drape Sheet With Drain Pouch 70 Cm X 70 Cm 976 Blades For Eye Surgery Crescent 977 Blades For Eye Surgery Side Port 15° 978 Blades For Eye Surgery Keratones 2.8 Mm 979 Blades For Eye Surgery Implant 5.2 Mm 980 Karman/ Mtp Cannula No. 6, Single Unit 981 Karman/ Mtp Cannula No. 7, Single Unit 982 Karman/ Mtp Cannula No. 8, Single Unit 983 Mr Cannula No. 5 984 Mr Cannula No. 6 985 Mr Cannula No. 7 986 Mr Cannula No. 8 987 Disposable Sterile ,Powder Free Gloves For Eye Surgeries Surgical Gloves 6.5 No, Latex, Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) Size 6.5 988 Disposable Sterile, Powder Free Gloves For Eye Surgeries Surgical Gloves 7 No, Latex, Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) Size 7 989 Disposable Sterile, Powder Free Gloves For Eye Surgeries Surgical Gloves 7.5 No, Latex, Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) Size 7.5 990 Ecg Paper 215 Mm*20 Mtr, Roll 991 Ecg Paper 50 Mm*20 Mtr, Roll 992 Ecg Paper 50 Mm*30 Mtr, Roll 993 Ecg Paper 60 Mm* 15 Mtr, Roll 994 Ecg Roll Big 995 Ecg Roll Small 996 Ecg Jelly 200 Ml Bottle 997 Ultrasound Jelly 200 Ml Bottle 998 Absorbable Gelatin Sponge, 80 X 50X 10 Mm, Single Unit 999 Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 6 Cm X 11 Cm (3 To 6 Units Of Mesh In One Box). 1000 Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 15 Cm X 15 Cm (3 To 6 Units Of Mesh In Each Box) 1001 Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 10Cm X 15 Cm Oval (1 Foil In Each Box) For Lap Of Hernia (Should Be Antibacterial) 1002 Multilayer Tissue Separating Mesh With Polypropylene/Polyster And Polydioxanone /Collegen. 15Cm X 15 Cm Square /Circular 1003 Surgical Spirit Bp 500 Ml 1004 Sodium Hypochlorite Solution 10% 1005 Acetone 400 Ml 1006 Dodecylbispropylene Triamine 9.2Gm, Didecyldimethyl Ammonium Chloride 13.0 Gm For Fogging 1007 Ortho-Phthaldehyde 0.55% W/W Solution For Sterlization, 5 Liter 1008 Potassium Peroxomonosulphate 50% W/W Containig Aldehyde Free Disinfectant , 5 Kg 1009 Dark Eye Glasses 1010 Disposable Eye Patch 1011 I.O Dye (Rhex Id Dye) Each (Indigo Blue Dye) 1012 Surgical Blades11 (Pack Of 100) 1013 Surgical Blades15 (Pack Of 100) 1014 Surgical Blades20 (Pack Of 100) 1015 Surgical Blades23 (Pack Of 100) 1016 Surgical Blades 24 (Pack Of 100) 1017 Oxygen Venti-Mask (Pvc/Disposable)Adult 1018 Oxygen Venti-Mask (Pvc/Disposable)Medium 1019 Oxygen Venti-Mask (Pvc/Disposable)Paed. 1020 Nebulisation Set (Mask With Tubing With Chamber (Adult ) 1021 Nebulisation Set (Mask With Tubing With Chamber (Paediatric ) 1022 Diaper Paediatric (Extra Small Size For Neonates) 1023 Disposable Adhesive Cannula Fixator 1024 Patient Identification Band Mother & Child Size (Different Colours) 1025 Patient Identification Band Adult Size (Different Colours) 1026 Patient Identification Band Paediatric Size (Different Colours) 1027 Suction Catheter No. 10 , Single Unit 1028 Suction Catheter No. 16 , Single Unit 1029 Negative Suction Drain/Closed Round Drain 12 1030 Negative Suction Drain No.14 1031 Negative Suction Drain No. 16 1032 Disposable Plastic Urine Pan 1033 Disposable Plastic Bed Pan 1034 Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 5X 6 Cm 1035 Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 7X 9 Cm 1036 Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 6.5 Cm X 5 Cm (Pack Of 100) 1037 Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 15.5 Cm X 8.5Cm (Pack Of 100) 1038 Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 25 Cm X 10 Cm , (Pack Of 100) 1039 Skin Stapler Standard ( Single Unit) 1040 Airway Set Size 2, ( Single Unit) 1041 Airway Set Size 3, ( Single Unit) 1042 Airway Set Size 4, ( Single Unit) 1043 Airway Set Size 5, ( Single Unit) 1044 Ambu Bag Adult, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 7 K Pa ( 70 Cm H2O Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 1300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) 1045 Ambu Bag Ped, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 4 K Pa ( 40 Cm H2O Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) 1046 Courtery Lead ( Single Unit) 1047 Coutery Pad (Single Unit) 1048 Lega Clip Size Lt 300 (Titanium Ligating Clips Medium Size Having Lateral And Transverse Grooves On The Inner Clips), (Single Unit) 1049 Lega Clip Size Lt 400 (Titanium Ligating Clips Large Size Having Lateral And Transverse Grooves On The Inner Clips), (Single Unit) 1050 Shoulder Immobilizer Standard 1051 Pouch Arm Sling Standard 1052 Centre Line 1053 Cervical Collar Small Size (Soft) 1054 Cervical Collar Medium Size (Soft) 1055 Cervical Collar Large Size (Soft) 1056 Hard Cervical Collar (Universal) Size 1057 Chest Drain Catheter No.12 1058 Chest Drain Catheter No.14 1059 Chest Drain Catheter No.28 1060 Chest Drain Catheter No.32 1061 Chest Tube Drainage With Water Seal Bag No.28 1062 Chest Tube With Water Seal No.32 1063 Dj Stunt 1064 Dj Stunt No.5.5 1065 Dj Stunt No. 6 French End Closed 1066 Dj Stunt No 5/26 Both End Open 1067 Dj Stunt No 6/26 Both End Open 1068 Epidural Set 1069 Guide Wire Teflon Coated J Tip 1070 Guide Wire Teflon Coated V Straight Tip 1071 Spc Set (Suprapubic Catheter Set) 1072 Turp Loop 1073 Skin Traction Set Standard Size 1074 I.V. Flow Regulator Extension Sets 1075 Blades For Eye Surgery Keratones 3.2 Mm 1076 Balance Salt Solution (Bss For Eye Surgery) 500 Ml 1077 Craner Wire Splint 1078 Air Mattress 1079 Bb Splint (Bohler- Braun) 1080 Bed Side Pulley 1081 Skeletal Traction 1082 Disposable Needle 16 1083 Disposable Needle 23 1084 Disposable Needle 26 1085 Pmo Line 1086 Troponin T, Sensitivity:-Not Less Than 95.8%, Direct Whole Blood Test Kit 1087 3D Mesh For Lap Ingunal Hernia A)Right Side B)Left Side - 1088 Partial Absorble (10X6 Cm)Vicryl Mesh For Ipom 1089 Tackers For Mesh Fixation (Non Absorable) 1090 Measured Volume Fluid Infusion Set With 110Ml/150Ml Chamber - 1091 Medical X-Ray Films(1X50) 8\X10\ 1092 Medical X-Ray Films(1X50) 10\X12\ 1093 Medical X-Ray Films(1X50) 12\X15\ 1094 Medical X-Ray Films(1X50) 14\X14\ 1095 Medical X-Ray Films(1X50) 14\X17\ 1096 Agfa Cr Film (Dt2B)(1X100) 8\X10\ 1097 Agfa Cr Film (Dt2B)(1X100) 10\X12\ 1098 Agfa Cr Film (Dt2B)(1X100) 11\X14\ 1099 Agfa Cr Film (Dt2B)(1X100) 14\X17\ 1100 Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R.B. Needle 1101 Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R.B. Needle 1102 Catgut Suture (Chromic Catgut)Usp 1, 76 Cm X 63 Mm, 3/8 Circle (12 Foils In Each Box) Round Body Needle - 1103 Chromic Catgut Absorbable Suture Usp 1,76Cm Length 1/2 Circle 40Mm, Round Body Needle (12 Foils In Each Box) 1104 Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle 1105 Silk Sutupak Usp 1, 75 Cm (12 Foils In Each Box) 1106 Silk Suture Usp 0, 76Cm X 45 Mm , 3/8 Circle Type Of Needle- Reverse Cutting (12 Foils In Each Box) 1107 Silk Suture Usp 3-0, 90 Cm X 16 Mm , 3/8 Circle Type Of Needle- Cutting (12 Foils In Each Box) 1108 Polyglactin (Violet) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box)Should Be Antibacterial 1109 Polyglactin (Violet) Vicryl Usp-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) Should Be Antibacterial 1110 Polyglactin (Violet) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box)Should Be Antibacterial 1111 Polyglactin (Plain) Vicryl Usp-1, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle Reverse Cutting - 1112 Polyglactin Synthetic Braided Absorbable Suture, Usp-1, 90Cm Length, Violet 1/2 Circle 40Mm Round Body Needle (12 Foils In Each Box) 1113 Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1114 Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied (12 Foils In Each Box) 1115 Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle (12 Foils In Each Box) 1116 Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body (12 Foils In Each Box) 1117 Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1118 Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting (12 Foils In Each Box) 1119 Suture Absorbable Surgical Suture Usp (Synthetic) Polyglactin 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle.Should Be Antibacterial. 1120 Knotless Control Device Polygecaprone 3/8 Circle Reverse Cutting Needle 24 Mm Spril Unidireectional 30Cm With Antibactreal Triclosan Coated 3/0 - 1121 Knotless Control Device Polygecaprone 1/2 Circle , 40 Mm ,Taper Point,Ct,Unidirectional With Fixation Tab 30Cm With Antibactreal Triclosan Coated 1/0 - 1122 Knotless Control Device Polygecaprone 1/2 Circle , 36 Mm ,Taper Point,Ct,Unidirectional With Fixation Tab 30Cm With Antibactreal Triclosan Coated 1 1123 Knotless Control Device Polygecaprone 1/2 Circle , 26 Mm ,Taper Point,Sh,Unidirectional With Fixation Tab 30Cm With Antibactreal Triclosan Coated 2/0 1124 Silver Alloy Non-Gamma-2 Lathe Cut Alloy 1125 Mercury Pure Triple Distilled 1126 Cavity Varnish 5% Sodium Fluoride 1127 Calcium Hydroxide, Powder 1128 Topical Fluoride Apf Gel 1.25% 1129 Gum Paint 1130 Edta 17 % Paste Form. 1131 Pulp Devitalizer 1132 Rubber Dam Kit 1133 Air- Rotor Diamond Burs No. 1 (Inverted Bur) 1134 Air- Rotor Diamond Burs No. 1 (Straight End Taper) 1135 Air- Rotor Diamond Burs No. 1 (Round) 1136 Air- Rotor Diamond Burs No. 1 (Straight) 1137 Air- Rotor Diamond Burs No. 1 (Flame) 1138 Air- Rotor Diamond Burs No. 2 (Inverted Bur) 1139 Air- Rotor Diamond Burs No. 2 ( Straight End Taper) 1140 Air- Rotor Diamond Burs No. 2 (Round) 1141 Air- Rotor Diamond Burs No. 2 (Straight) 1142 Air- Rotor Diamond Burs No. 2 (Flame) 1143 Air- Rotor Diamond Burs No. 3 (Inverted Bur) 1144 Air- Rotor Diamond Burs No. 3 ( Straight End Taper) 1145 Air- Rotor Diamond Burs No. 3 (Round) 1146 Air- Rotor Diamond Burs No. 3 (Straight) 1147 Air- Rotor Diamond Burs No. 3 (Flame) 1148 K-Files - Size- 15-40 , Length:-21 Mm , Should Have Rubber Stopper 1149 K-Files - Size- 15-40 , Length:-25 Mm , Should Have Rubber Stopper 1150 K- Files Size- 45-80, Length:-25 Mm, Should Have Rubber Stopper 1151 K-Files Size- 6, Length :- 21 Mm , Should Have Rubber Stopper. 1152 K-Files Size- 6, Length :- 25 Mm , Should Have Rubber Stopper. 1153 K-Files Size- 8, Length :- 21 Mm , Should Have Rubber Stopper. 1154 K-Files Size- 8, Length :- 25 Mm , Should Have Rubber Stopper. 1155 K-Files Size- 10, Length :- 21 Mm , Should Have Rubber Stopper. 1156 K-Files Size- 10, Length :- 25 Mm , Should Have Rubber Stopper. 1157 Niti Hand Files (21 Mm) Size- 15-40, For Curved Canals 1158 H-Files , Size-15-40 , Length :-21 Mm, Should Have Rubber Stopper 1159 H-Files , Size-45-80, Length :-25 Mm Should Have Rubber Stopper 1160 Matrix Strips,Made From A Thin, Strong, Flexible, Transparent Material Such As Mylar 1161 Barbed Broaches , Made Of Stainless Steel, Can Be Sterilized Length ‰¥ 21 1162 Articulating Paper Strip, Red Colored With Sufficient Thickness Double Side 1163 Articulating Paper Strip, Blue Colored With Sufficient Thickness Double Side 1164 Matrix Band Retainer , No. 1 1165 Matrix Band Retainer , No.8 1166 Matrix Band , No. 1, Toflemire 1167 Matrix Band , No. 8, Toflemire 1168 Paper Point 25 1169 Paper Point 30 1170 Paper Point 35 1171 Mini Plates Isi/ Iso/Ce/Marked. 1172 Arch Bar Length 1Feet Isi/ Iso/Ce/Marked. 1173 Air Rotor Cartridges (Nsk) Supertorque, Standard Head Isi/ Iso/Ce/Marked. 1174 Composite Finishing Kit- Disc Type 1175 Composite Finishing Kit With 12 To 24 Finishing Point Of Different Shapes. The Durable Abbresive Points Are Autoclavabal And Cost Effective, Comprehensive Selection Of Plain For Finishing And Polishing In One Kit, For Fast And Efficient Finishing The Use Of Conjunction With The Composite Polishing Kit, Average Speed 5000 To 12000 Rpm Kit - 1176 Iopa Film Size 30 Mm X 40 Mm 1177 Iopa Film Size 31 Mm X 41Mm 1178 Formocresol Formalin, Cresol Glycerin ,Formocresol Formalin Bp 20% V/V , Cresol Ip 32% V/V , Glycerin Ip Qs 1179 Dental Chair Covering Sterilized Cling Foil Rolls Isi/ Iso/Ce/Marked. 1180 Small Cotton Rolls For Isolation Isi/ Iso/Ce/Marked(Length-37Mm, Dia-8-10Mm) 1181 Restroative Cement Type - Ii - (15 Gm Powder & 10 To 13 Gm Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Resistant To Demineralization,Hydrophylic Properties, Flouride Releasing, High Compressive Stregth, Low Solubility, Low Flexure Strength, Bonds To Both Dentin And Enamel. Shade :- Pale Yellow Powder & Liquid 15Gm Powder & 10 To 13 Liquid 1182 Restroative Cement Type - Ii - (15 Gm Powder & 10 To 13 Gm Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Resistant To Demineralization,Hydrophylic Properties, Flouride Releasing, High Compressive Stregth, Low Solubility, Low Flexure Strength, Bonds To Both Dentin And Enamel. Shade :- Yellow Brown Powder & Liquid 15Gm Powder & 10 To 13 Liquid 1183 Restroative Cement Type - Ii - (15 Gm Powder & 10 To 13 Gm Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Resistant To Demineralization,Hydrophylic Properties, Flouride Releasing, High Compressive Stregth, Low Solubility, Low Flexure Strength, Bonds To Both Dentin And Enamel. Shade :- Dark Grey Powder & Liquid 15Gm Powder & 10 To 13 Liquid 1184 Pit & Fissure Sealant ( 6 Ml Bottle) Solution With High Flouride Releasing, Low Viscocity, High Retention, Rapid Cure & Low Solubility Liquid 6 Ml 1185 Calcium Hydroxide , Paste System Based And Catalyst -Radiopaque, 4 Gm Paste 4 Gm 1186 Zinc Phosphate Cement , 20 Gm Powder And 10 Ml Liquid Powder & Liquid 20 Gm Powder And 10 Ml Liquid 1187 Glass Ionomer Cement- Type-Ix, High Strenth For Posterior Teeth, Chemical Setting Without Shrinkage, Strontium Based, High Flouride Releasing, 12 To 15 Gm Powder And 5 To 10 Gm Liquid Powder & Liquid 12 To 15 Gm Powder & 5 To 10 Ml Liquid 1188 Hybrid Composite Resin For Anteriors (All Shades), High Strength, Long Lasting Wear Resitance, Great Handling Without Stick, 4 Gm Isi/ Iso/Ce/Marked. 4 Gm 1189 Mineral Trioxide Aggregate, 0.5 Gm Isi/ Iso/Ce/Marked. 0.5 G 1190 Flowable Composite 2 Mg Syringe, Flowable Consistancy Thicsotrophic, Low Shrinkage, Radiopaque, Easily Polishability, Should Be Hybrid, Wear Resistance, Syringe Design To Eleminate Bubbles 2 Mg 1191 Niti Rotory Files 4%, 21 Mm (Pkt Of 6) Refill Pack Of(#15,#20,#25,#30,#35,#40) 21 Mm 1192 Niti Rotory Files 4%, 25 Mm (Pkt Of 6) Refill Pack Of (#15,#20,#25,#30,#35,#40) 25 Mm 1193 Niti Rotory Files 6%, 21 Mm (Pkt Of 6) Refill Pack Of( #15,#20,#25,#30,#35,#40) 21 Mm 1194 Niti Rotory Files 6%, 25 Mm (Pkt Of 6) Refill Pack Of( #15,#20,#25,#30,#35,#40) 25 Mm 1195 Crown Cutting Kit, Set Of 14 Burs - 1196 Adhesive Resin Cement (Dual Lock Composite Resin Cement), 4.5 Gm Isi/Iso/Ce Marked Cement 4.5 Gm 1197 Etchant 37% Phosphoric Acid ( 9 Ml Syringe) Solution 1198 Root Canal Spreader 15-40, 21 Mm Isi/Iso/Ce Marked 1199 Root Canal Spreader 15-40, 25 Mm Isi/Iso/Ce Marked 1200 Gutta Percha Point No. 20, Isi/Iso/Ce Marked 1201 Gutta Percha Point No. 25, Isi/Iso/Ce Marked 1202 Gutta Percha Point No. 30, Isi/Iso/Ce Marked 1203 Gutta Percha Point No. 15-40, Isi/Iso/Ce Marked 1204 Gutta Percha Point No. 45-80, Isi/Iso/Ce Marked 1205 Absorbent Point No.15-40, Isi/Iso/Ce Marked Packet Of 200 1206 Absorbent Point No.45-80, Isi/Iso/Ce Marked Packet Of 200 1207 Stainless Steel Wire 26G. Soft Isi/Iso/Ce Marked 1208 Gates Glidden Drill No.1 1209 Gates Glidden Drill No.2 1210 Gates Glidden Drill No.3 1211 Pillow Cover Cotton Size:48 X 70 Cm, Color - Violet 1212 Pillow Cover Cotton Size:48 X 70 Cm, Color - Indigo 1213 Pillow Cover Cotton Size:48 X 70 Cm, Color - Blue 1214 Pillow Cover Cotton Size:48 X 70 Cm, Color - Green 1215 Pillow Cover Cotton Size:48 X 70 Cm, Color - Yellow 1216 Pillow Cover Cotton Size:48 X 70 Cm, Color - Orange 1217 Pillow Cover Cotton Size:48 X 70 Cm, Color - Peach 1218 Bed Sheet Size-150 X 240 Cm, Color:Violet 1219 Bed Sheet Size-150 X 240 Cm, Color:Indigo 1220 Bed Sheet Size-150 X 240 Cm, Color:Blue 1221 Bed Sheet Size-150 X 240 Cm, Color:Green 1222 Bed Sheet Size-150 X 240 Cm, Color:Yellow 1223 Bed Sheet Size-150 X 240 Cm, Color:Orange 1224 Bed Sheet Size-150 X 240 Cm, Color:Peach 1225 Ot Linen Poplin- Green Color, Size : 90 X 90 1226 Ot Linen Poplin- Green Color, Size : 90 X 140 1227 Ot Linen Poplin- Green Color, Size : 140 X 210 1228 Ot Linen Poplin- Green Color, Size : 90 X 90 (With Oval) 1229 Ot Linen Poplin- Green Color, Size : 90 X 140 (With Circular Hole Of Size 10€ Diameters In Centers Green Color) 1230 Ot Linen Poplin- Green Color, Size : 130 X 180 (With Circular Hole Of Size 10€ Diameters In Centers Green Color) 1231 Ot Linen Cotton White 88X88 Cm. With Hole Size 9 X 10 Cm. In Centre And Should Be Folded And Stitched So There Are No Loose Ends. 1232 Ot Gown Poplin Length 130 X 135 Cms Arm’S Length 58 X 60 Back Open Type With Provision Of Tying With String At Back Arm Should Have Elasting Cuff Or Cord For Tying At Cuff End. The Inside Of Gown Should Be Inter Lock So That There Are No Loose Threads 1233 Patient Dress Kurta Payjama (Striped Blue) Small. Kurta Length 70 X 80 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1234 Patient Dress Kurta Payjama (Striped Blue) Medium. Kurta Length 80 X 90 Cms Arm Length 22X 24 Cms.V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1235 Patient Dress Kurta Payjama (Striped Blue) Large. Kurta Length 100 X 105 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1236 Doctor Dress Kurta Payjama (Blue) Small. Kurta Length 70 X 80 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1237 Doctor Dress Kurta Payjama (Blue) Medium. Kurta Length 80 X 90 Cms Arm Length 22X 24 Cms.V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1238 Doctor Dress Kurta Payjama (Blue) Large. Kurta Length 100 X 105 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) 1239 Towel 56 X 115 Cms. White Color 1240 Dental Sheet Green Cotton 45 X 45 Cms. 1241 Aprons (Lab Coats ) (Small) Full Size, Full Sleeves 1242 Aprons (Lab Coats) (Medium) Full Size, Full Sleeves 1243 Aprons (Lab Coats) (Large) Full Size, Full Sleeves 1244 Legging Each Leg Poplin 40 X 40 Cms. Green Color Bottom Closed 1245 Drape Sheet For Cssd 2 X2 Mtr. Cotton Cloth Grey Color 1246 Kurta, Petticoat Sets Large Size , Green Strip 1247 Glass Lonomer Silver Reinforced Isi/Iso/Ce Marked 1248 Glass Lonomer Luting Cement Isi/Iso/Ce Marked 1249 Rubber Dam Sheet Isi/Iso/Ce Marked 1250 Sterilization Rolls For Packing Instrument 15Cm X 200Mtrs 1251 Collagen Membrane-Sterile Bioresorbable Gtr Collagen Membrane Isi/Iso/Ce Marked 1252 6% Taper Gutta Percha Size 25 1253 6% Taper Gutta Percha Size 30 1254 6% Taper Gutta Percha Size 35 1255 6% Taper Gutta Percha Size 40 1256 4% Taper Gutta Percha Size 25 1257 Esthetic Fiber Post System 1258 Pre Fabricated Metallic Post ( Cemented) 1259 Pre Fabricate Metallic Post (Threaded) 1260 Rubber Base Impression Material Addition Silicone Putty With Compatible Light Body 600-900Ml Putty With 50 Ml Light Per 300Ml Of Putty Isi/Iso/Ce Marked 1261 Retraction Cord (Assorted Size Isi/Iso/Ce Marked 1262 Bone Graft Material For Dental Purpose Isi/Iso/Ce/Marked 1263 Surgical Bur Straight Fissure Carbide 1 Mm Isi/Iso/Ce/Marked 1264 Surgical Bur Straight Fissure Carbide 1.5 Mm Isi/Iso/Ce/Marked 1265 Surgical Bur Straight Fissure Carbide 2 Mm Isi/Iso/Ce/Marked 1266 Resin Cement Isi/Iso/Ce Marked 1267 Preadjusted Edgewise Stainless Steel Brackets Kit Containing Upper & Lower 2Nd Premolar To 2Nd Premolar Bondable Brackets With Upper Triple And Lower Double Weldable Buccaltubes,With Roth And Mbt Prescription And 0.022€And 0.018€ Slot (Leone/American Orth 1268 Ni Ti Preformed Orthodontic Wire Round - 014 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1269 Ni Ti Preformed Orthodontic Wire Round - 016 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1270 Ni Ti Preformed Orthodontic Wire Round - 018 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1271 Ni Ti Preformed Orthodontic Wire Round - 020 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1272 Ni Ti Preformed Orthodontic Wire Rectangular -016X022 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1273 Ni Ti Preformed Orthodontic Wire Rectangular -017X025 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1274 Ni Ti Preformed Orthodontic Wire Rectangular -019X025 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked 1275 Stainless Steel Preformed Orthodontic Wire Round 014 Inch (Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1276 Stainless Steel Preformed Orthodontic Wire Round 016 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1277 Stainless Steel Preformed Orthodontic Wire Round 018 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1278 Stainless Steel Preformed Orthodontic Wire Round 020 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1279 Stainless Steel Preformed Orthodontic Wire Rectangular 016X022 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1280 Stainless Steel Preformed Orthodontic Wire Rectangular 017X025 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1281 Stainless Steel Preformed Orthodontic Wire Rectangular 019X025 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked 1282 Blue Elastic Separators ( Leone/ American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked 1283 Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Short Types Isi/Iso/Ce Marked 1284 Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Long Types Isi/Iso/Ce Marked 1285 Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Continous Types Isi/Iso/Ce Marked 1286 Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Yellow Isi/Iso/Ce Marked 1287 Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Blue Isi/Iso/Ce Marked 1288 Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Green Isi/Iso/Ce Marked 1289 Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Red Isi/Iso/Ce Marked 1290 Colourless O Rings (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1291 Expansion Screw 3 Pin (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1292 Preformed Molar Bands Without Buccal Tubesisi/Iso/Ce Marked 1293 Bioplast Sheets Proprietary Item 2 Mm Thickness Isi/Iso/Ce Marked 1294 Bioplast Sheets Proprietary Item 3 Mm Thickness Isi/Iso/Ce Marked 1295 Stainless Steel Wire Spool ( Leone / Konark/Ss White) 19 Gauge Isi/Iso/Ce Marked 1296 Stainless Steel Wire Spool ( Leone / Konark/Ss White) 20 Gauge Isi/Iso/Ce Marked 1297 Stainless Steel Wire Spool ( Leone / Konark/Ss White) 21 Gauge Isi/Iso/Ce Marked 1298 Stainless Steel Wire Spool ( Leone / Konark/Ss White) 23 Gauge Isi/Iso/Ce Marked 1299 Tma Wire Lengths Rectangular - 017 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1300 Tma Wire Lengths Rectangular - 019 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1301 Tma Wires Preformed Rectangular- 017 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1302 Tma Wires Preformed Rectangular- 019 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked 1303 Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 6Mm Isi/Iso/Ce Marked 1304 Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 7Mm Isi/Iso/Ce Marked 1305 Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 8Mm Isi/Iso/Ce Marked 1306 Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 10 Mm Isi/Iso/Ce Marked 1307 Forsus Fatigue Resistant Device( 3 M Unitek ), Proprietary Itemisi/Iso/Ce Marked 1308 Powerscope 2 (American Orthodontics Proprietary Item)Isi/Iso/Ce Marked 1309 Etchant 37% Phosphate Acid In Gel Form 2-4 Gm, Isi/Iso/Ce Marked 1310 Loose Preadjusted Edgewise Mbt Bracket 022 Slot Isi/Iso/Ce Marked Per Bracket 1311 Bondable Buccal Tubes Upper And Lower Right And Left 1St Molars .022€ Mbt With Upper Triple And Lower Double Slot (Desires/ Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked 1312 Bondable Buccal Tubes Upper And Lower Right And Left 2Nd Molars .022€ Mbt (Desires/ Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked 1313 Ni-Ti Open Coil Spring0 10€X 030 (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marke 1314 Niti Closed Coil Springs With Hooklets (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek 9Mm Isi/Iso/Ce Marked 1315 Niti Closed Coil Springs With Hooklets (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek 12Mm Isi/Iso/Ce Marked 1316 Eugenol 110 Ml Isi/Iso/Ce Marked 1317 Zinc Oxide Powder 110 Gram Isi/Iso/Ce Marked 1318 Naoci 5.25% Solution Isi/Iso/Ce Marked 1319 Fiber-Reinforced Splinting Material- Bondable Reinforced Ribbon Fiber-Approx. 2Mm Width Isi/Iso/Ce Marked 1320 Fixer & Developer Solution Set (Manual) To Make 13.5 Lt Solution Each Of Fixer And Developer Isi/Iso/Ce Marked 1321 Air Rotor Spray Isi/Iso/Ce Marked Bottle 1322 Disposable Patient Drape Sheets Size 1X1 Mtrs. 1323 Single Use Syringes 10 Ml With Needle 23 G. X 1€ Length Sterile Isi/Iso/Ce Marked 1324 Single Use Syringes 5 Ml With Needle 23 G. Sterile 1€ Length Isi/Iso/Ce Marked 1325 Single Use Syringes 2 Ml With Needle 23 G. Sterile 1€ Length Isi/Iso/Ce Marked 1326 Single Use Insulin Syringes With Needle Sterile Isi/Iso/Ce Marked 1327 B.P. Blade Size 11 Isi/Iso/Ce Marked 1328 B.P. Blade Size 15 Isi/Iso/Ce Marked 1329 B.P. Blade Size 23 Isi/Iso/Ce Marked 1330 Silk Suture Material (3-0) 1331 N-95 Respirator Mask(Covid) 1332 Ppe Kit(Covid) 1333 Vtm Media(Covid) 1334 Triple Layer Mask(Covid) 1335 Hydroxy Chloroquine Tablet 200 Mg(Covid) 1336 Lysol(5L)(Covid) 1337 Sodium Hypochlorite(5L)(Covid) 1338 Oxygen Cylinder(Covid) 1339 Real Time Pcr Kit(Covid) 1340 Covid19 Igm/Igm Rapid Test (Wondfo Sars-Cov-2 Antibody Test)(Covid) 1341 Dead Body Cover(Covid) 1342 Rapid Screening Kits For Covid-19 Test(Covid) 1343 Denture Spirit-Surgical Spirit With Methyl Salicylate, Diethyl Phthalate And Caster Oil Dentured Alchol, 500 Ml Bottle(Covid) 1344 Disposable Bed Sheet(Covid) 1345 Thermal Scanner(Covid) 1346 Tab Levocetrizine 5 Mg(Covid) 1347 Spun Bond Non-Woven 3 Ply Face Covers(Covid) 1348 Magna Pure 24 Total Na Isolation Kit, Pack Size-96(Covid) 1349 Magna Pure 24 Processing Cartridge, Pack Size-48(Covid) 1350 Magna Pure 24 Tip Ptark (Comes With Pierecing Tools)Pack Size-48(Covid) 1351 Magna Pure Tip 1000 Ul, Pack Size-3840(Covid) 1352 Framestrips With Flat Caps High Profile, Pack Size-120(Covid) 1353 Magna Pure Sealing Foil,Pack Size-100(Covid) 1354 Mplct Na Isolation Kit- Lysis/ Binding Buffer Refill, Pack Size-100Ml(Covid) 1355 Handsanitizer (500 Ml)(Covid) 1356 Framestrip With Flat Caps-Low Profile(Covid) 1357 Magna Pure 96 External Lysis Buffer(Covid) 1358 Light Cycler -480 Multiwell 11 Plate 96(Covid) 1359 Light Cycler 8-Tube Strip Adapter Plate(Covid) 1360 Manual Rna Extraction Kit-50 Test(Covid) 1361 Oseltamivir 75 Mg 1362 Covid Kavachâ„¢ Anti- Sars Cov-2 Igg Antibody Detection Elisa (96 Micro Well Coated Plate 1363 Tocilizumab Injection 400 Mg/20 Ml(Covid) 1364 Standard Q Covid19,Ag Test(Rapid Antigon Test) 1365 Lc Prep Lysi/Bind Buff Dna,Mbp 1366 Ramdesivir Injection 100Mg 1367 Hydroxychlorine Tablet 400 Mg(Covid) 400 Mg 1368 Dexamethasone 6 Mg Tablet(Covid) 6 Mg 1369 Enoxaparin 40 Mg Injection(Covid) 40 Mg 1370 Favipiravir(Covid) 400 Mg 1371 Coronil Kit Coronil Kit Each Contains(80Tab+80Tab+20Ml) 1372 Ayush Kwath Powder 1373 Amphotericin B Powder For Injection 50 Mg Liposomal Complex,Vial Injection Powder 50Mg/Ml, 10Ml Vial 1374 Tocilizumab 80 Mg 1375 Oxygen Regulator With Humidifier Bottle,Rotameter And Key For B And D Type Cylinders 1376 Disposable Ad Syringes 0.5Ml. 1377 Nitrile Gloves(Large Size),Purple,Powder Free,Box Of 100 Pcs 1378 Nitrile Gloves(Medium Size),Purple,Powder Free,Box Of 100 Pcs 1379 Nitrile Gloves(Small Size),Purple,Powder Free,Box Of 100 Pcs 1380 Tablet Posaconazole 100 Mg 1381 Intravenous Immunoglobulin(Ivig) 10 Gm,100 Ml Bottle 1382 Sars-Cov-2 Sequencing Kits Test Kit Kit 1383 Corbevax Vaccine,10 Ml Vial 1384 Zinc Oxide Cream 10% 10 Gm 1385 Zinc Oxide Powder 100 Gm 1386 Zinc Phosphate Cement , Powder And Liquid 1387 Zinc Sulphate Dispersible Tablet 20 Mg 1388 Zinc Sulphate Syrup 60 Ml 1389 Zoledronic Acid Injection 4 Mg 1390 Balloon Tamponade (Standard Size) 1391 Miracle Mix(Standard Size) 1392 Bonding Agent 1393 Endo Files(Standard Size) 1394 Orafill(Standard Size) 1395 Pain Off(Standard Size) 1396 Composite Syringes A1(Standard Size) 1397 Composite Syringes B1(Standard Size) 1398 Lignocaine Spray 1399 Dycal(Standard Size) 1400 Metapex(Standard Size) 1401 Restoration Bonding Agent 1402 Mixing Pad(Standard Size) 1403 Coe-Pack(Standard Size) 1404 Temephos 50% 1 Ltr 1405 Pyrazinamide 500 Mg Tablet 1406 Pyrazinamide 750Mg Tablet 1407 Rifampicin 150 Mg Capsule 1408 Rifampicin 300 Mg Capsule 1409 Rifampicin 450 Mg Capsule 1410 Isoniazid 300 Mg Tab. 1411 Isoniazid 100 Mg Tab. 1412 Ethanbutol 800 Mg Tab. 1413 Ethanbutonl 400 Mg. Tab. 1414 Ethanbutol 100 Mg Tab. 1415 4 Fdc (A) 1416 3 Fdc (A) 1417 Inj. Streptomycetin 0.75 Gm 1418 3 Fdc Ped. (P) 1419 2 Fdc Ped. (P) 1420 Pas Poder 1421 Iec Jel Pack 1422 Tharmocal Box 1423 Falcon Tube 50 Ml 1424 Tab. Pyridoxin 50 Mg 1425 Inj. Kanamicine 18 M 1426 Tab. Cyclocerin 500 Mg 1427 Tab. Cyclocerin 250 Mg 1428 Tab. Ethonamlde 250 Mg 1429 Tab. Uvezolld 1430 Tab. Clofazimine 100 Mg 1431 Tab. Coprpcomycine 1 Mg 1432 Tab. Delamanid 50 Mg 1433 Tab. Moxifloxacin 400 Mg 1434 Multi Drug Urine Screen Kits 1435 Cotton Bandages(1 X 12 Rolls) 10 Cm X 4 Mtrs 1436 Cotton Bandages(1 X 12 Rolls) 15 Cm X 5 Mtrs 1437 Cotton Bandages(1 X 12 Rolls) 5 Cm X 4 Mtrs 1438 Cotton Gauze Cloth(1 X 5 Than) 90 Cm X 18 Mtrs 1439 Cotton Wool Ip 100 Gm 1440 Cotton Wool Ip 500 Gm (Net) 1441 Cotton Wool Ip 500 Gm 1442 Disposable Cap 1443 Disposable Surgical Gloves No. 6.5, Isi Mark 1444 Disposable Surgical Gloves No. 7, Isi Mark 1445 Disposable Surgical Gloves No. 7.5, Isi Mark 1446 Disposable Surgical Gloves No.6 , Isi Mark 1447 Disposable Syringe 20 Ml With Needle, Ribbon Pack 1448 Disposable Syringe 50 Cc With Needle, Ribbon Pack 1449 Disposable Syringes 1 Ml (23G), Ribbon Pack 1450 Disposable Syringes 10 Ml. With Needle, Ribbon Pack 1451 Disposable Syringes 2 Ml, (23G), Ribbon Pack 1452 Disposable Syringes 2 Ml, (24G), Ribbon Pack 1453 Disposable Syringes 5 Ml, (23G), Ribbon Pack, Reuse Preventable 1454 Disposable Sterile Powder Free Gloves For Eye Surgeries Surgical Gloves 6.5 No Latex Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Puncture Resistant, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) 1455 Disposable Sterile Powder Free Gloves For Eye Surgeries Surgical Gloves 7 No Latex Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Puncture Resistant, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) 1456 Disposable Sterile Powder Free Gloves For Eye Surgeries Surgical Gloves 7.5 No Latex Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Puncture Resistant, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) 1457 Disposable Shoe Cover 1458 Disposable Insulin Syringe (31G), Ribbon Pack 1459 Disposable Mask 1460 Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R.B. Needle 1461 Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R.B. Needle 1462 Suture Absorbable Surgical Suture Usp (Synthetic) Polyglactin 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle 1463 Suture Catgut 3-0No. R.B. Needle 1464 Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle 1465 Suture Silk 2-0No. R.B. Needle 1466 Polyglactin (Plain) Vicryl Usp-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1467 Polyglactin (Plain) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1468 Polyglactin (Plain) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1469 Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body (12 Foils In Each Box) 1470 Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle (12 Foils In Each Box) 1471 Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1472 Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting (12 Foils In Each Box) 1473 Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied (12 Foils In Each Box) 1474 Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) 1475 Stadiometer 1476 Wooden Stick (Oral Examination) 1477 Bp Appratus 1478 Weighing Machine (Digital) 1479 Acetic Acid 100% 1480 Swab Sticks For Vig Examanation 1481 Torch 1482 Mouth Mirror 1483 Disttled Water 1484 Wooden Tongue Depressor 1485 Mantoux Test 1486 Albumin (5X50Ml) 1487 Alkline Phosphtase 4X24 + 4X6Ml) 1488 Bilirubin Kit 4X60Ml) 1489 Cholestrol Kit 5X30Ml) 1490 Creatinine Kit (4X60M)L 1491 Ggt (5X6.5Ml) 1492 Glucose Kit (5X60Ml) 1493 Hdl Kit (4X30Ml + 4X10Ml) 1494 High Control For Semi Auto (1X5Ml) 1495 Normal Control For Semi Auto (1X5Ml) 1496 Sgot Kit (4X24Ml + 4X6Ml) 1497 Sgpt Kit (4X24Ml + 4X6Ml) 1498 Total Protein (5X50Ml) 1499 Triglycerides Kit (4X24Ml + 4X6Ml) 1500 Urea Kit (4X24Ml + 4X6Ml) 1501 Uric Acid Kit (4X24Ml + 4X6Ml) 1502 Wash Kit (4X50Ml) 1503 Reagent For Fully Automatic Bio-Chemistry Analyser Bs400 Which Must Be In Liquid State Stable Form 1504 Alkaline Phosphate 8X50 / 8X12.5Ml 1505 Amylase 4 X 20 Ml/ 2 X 10 Ml 1506 Bilirubin Total 8X50 / 8X12.5Ml 1507 Bilirubin Direct 8X50 / 8X12.5Ml 1508 Cholestrol 8X50Ml 1509 Crp Fs 1X20 / 1X10Ml 1510 Ck - Nack 4 X 20 Ml/ 2 X 10 Ml 1511 Cpk - Mb 4 X 20 Ml/ 2 X 10 Ml 1512 Creatinine 8X50 / 8X12.5Ml 1513 D-Dimer 2X12Ml + 1X8Ml 1514 Ferritin 2X20 / 1X10Ml 1515 Glucose 8X50/8X12.5Ml 1516 Hdl 4X20 / 2X10Ml 1517 Hba1C 2X15 / 1X10 / 1X5Ml 1518 Hba1C 3X20/ 2X10 / 1X10Ml 1519 Hemolyzing Solution 500 Ml 1520 Iron Tibc 4X20 / 2X10 1521 Ldh 8X50Ml + 8X12.5Ml 1522 Ldl 4X20 / 2X10Ml 1523 Lipase 4X20 / 2X10Ml 1524 Ra Factor 2X20 / 1X8Ml 1525 Acetec Acid 5% 1526 Tablet Chlorine 1527 Capillary Tubes 1528 Card For Haemo Spot 1529 Centrifuge Tube Stand 15 Ml(10*2) 1530 Centrifuge Tube Stand 50 Ml(15*2) 1531 Conical Flask 500 Ml 1532 Coplin Jars 1533 Covid Elisa Antigen Kit (Icmr Approved) 1534 Crp 50 Test Kit (Qualitative) 1535 Cryo Box With Lid 1536 Cryo Vials 2 Ml 1537 Cup For Bs400 Chemistry Analyzer 1538 Diamond Marking Pencils 1539 Disposable 3 Ply Mask 1540 Disposable Alcohol Swab 1541 Disposable Cap 1542 Disposable Esr Pipette 1543 Disposable Esr Tube (Westergen Method) 1544 Disposable Gown 1545 Disposable Shoe Cover 1546 Distilled Double Dionized Water 5 Ltr 1547 Distilled Triple Dionized Water 5 Ltr 1548 Distilled Dionized Water 5 Ltr 1549 Drums Tube 1550 Ecg Jelly/Usg Jelly 1551 Edta Vial (Non Vacuum) 1552 Edta Vial (Vacuum) 1553 Eppen Drop Vial ( Mct ) 1554 Esr Black Vial (Non Vacuum) 1555 Esr Black Vial (Vacuum) 1556 Esr Stand 1557 Face Shield 1558 Falcon Tube Rack 1559 Falcon Tube (All Size) 1560 Filter Paper 1561 Filter Tip 100 Micro Litre (1*960) 1562 Filter Tip 20 Micro Litre (1*960) 1563 Filter Tip 10 Micro Litre (1*960) 1564 Filter Tip 200 Micro Litre (1*960) 1565 Filter Tip 5 Micro Litre (1*960) 1566 Floride Vial (Non Vacuum) 1567 Floride Vial (Vacuum) 1568 Gel Iec Pack 1569 Glass Bottel Round 1570 Glass Cover Slip 22 Mm 1571 Glass Pipette 10Ml 1572 Glass Pipette 2Ml 1573 Glass Pipette 5Ml 1574 Glass Slide 1575 Glucostix 50 Sticks 1576 Hand Sanitizer 5 Ltr (Ip Base) 1577 Hb Pipette 1578 Hb Tube 1579 Hbsag Card 1580 Hcv Rapid Card 1581 Hiv Rapid Card 1582 Insulated Sample Transportation Box 1583 Lancet (Auto Destroyable/Safety Lancet) 1584 Lancet (Twisted Round) 1585 Leucoreduction Filter 1586 Malaria Antigen Card 1587 Mct Vials 1.5Ml 1588 Mct Vials 2.0Ml 1589 Measuring Cylender 20Ml 1590 Measuring Cylender 100Ml 1591 Measuring Cylender 500Ml 1592 Measuring Cylender 1000Ml 1593 Microscope Cover Glass 22 X 40 Mm 1594 Multistix 1595 N/10 Hcl 500Ml 1596 Parafilm Tape 1597 Pastuer Pipette 1598 Ph Paper 5.0 To 7.5 1599 Plain Vial (Non Vacuum) 1600 Plain Vial (Vacuum) 1601 Ppe Kit (Citra & Drda Approved) 1602 Pregnancy Cards 1603 Ra Factor 50 Test Kits 1604 Reversible Rack Mct 1605 Rubber Teat For Pipette 1606 Slide Storage Rack 1607 Slide Storage Tray Pvc 1608 Sodium Citrate Vials Non Vaccum 1609 Sodium Citrate Vials Vaccum 1610 Sodium Hypochloride 5 % 5 Ltr 1611 Sst Vials Non Vaccum 1612 Sst Vials Vaccum 1613 Steel Rack For Test Tube 48 Hole 1614 Sterile Swab Stick 1615 Sterlum 500Ml 1616 Stickers For Slide (Per Piece) 1617 Test Tube Glass 12*100 1618 Test Tube Glass 12*75 1619 Test Tube Glass 15*150 1620 Test Tube Glass 25*150 1621 Test Tube Stand 1X 10 Slots 1622 Test Tube 1X 30 Slots 1623 Thermocol Box 1624 Thermal Paper Roll 1625 Tissue Paper Roll 20 Meter 1626 Tourniquate 1627 Sample Cup With Label (3 Screw, Sterile)/ Sputum Cup 1628 Uristix 100 Strips 1629 Vaccutainer 1630 Vaccutainer Needle 1631 Vtm Swab Stick (Standard Size) 1632 Washing Brush . For Test Tube (Standard Size) 1633 Widal Kit (Slide Method) 1634 Wipes 1*280 Pc Lab Grade 1635 Yellow Tips 1X1000 Nos 1636 Zip Lock Pouch For 1 Ltr 1637 Anti-D Igg 10 Ml 1638 Anti-D Igm 10 Ml 1639 Copper Sulphate Powder 500Gm 1640 Dpx Mount 1641 Ethanol Absolute 1642 Fouchet Reagent 1643 Giemsa Stain 125 Ml 1644 Glacial Acetic Acid 1645 H & E Stain (Haematoxillin Stain) 1646 J.S.B 1 Stain 1647 J.S.B 2 Stain 1648 Lieshmen Powder 25 Gm 1649 Lugal Iodine 125 Ml 1650 Manual Rna Extraction Kit 50 Test (Icmr Approved) 1651 Mathenol 2.5 Ltrs 1652 Naoh Sodium Hydroxide 1653 Oil Immersion 25Ml 1654 Rapid Pap Stain Kit 1655 Rapid Test Kit Igg, Igm, Ns1 For Dengue 1656 Rtpcr Kits 96 Test For Covid-19 (Icmr Approved) 1657 Siprit 1658 Sodium Chloride 1659 Sodium Dehydrogen Orthophosphate 1660 Sodium Hydrogen Orthophosphate 1661 Sodium Hypochloride 10% 1662 Sulphar Powder 500 Gm 1663 T3 Elisa (96 Test) 1664 T4 Elisa (96 Test) 1665 Tsh Elisa (96 Test) 1666 Xylene 1667 Anti Ab 1668 Anti D ( Igg+ Igm) 1669 Anti Human Sera/ Coombs Sera 1670 Blood Grouping Plate 1671 Bovine Albumin 1672 Single Blood Bag 350 Ml 1673 Triple Blood Bag 450 Ml 1674 Double Blood Bag 350 Ml(Sagm) 1675 Double Blood Bag 350 Ml 1676 H.I.V Elisa 4Th Generation (96 Test) 1677 Hb Strips 1678 Hbsag Elisa 4Th Generation (96 Test) 1679 Hcv Elisa 4Th Generation (96 Test) 1680 Quadraple Blood Bags 450Ml 1681 Single Blood Bag 350Ml 1682 Vdrl Card 1683 Absolute Alcohol 95% (500 Ml) 1684 Acetone (500Ml) 1685 Hiv Tridot Rapid Cards 1686 Biological Indicator 1687 Bunsen Burner 1688 C.L.E.D Agar 500Gm 1689 Carbol Fuchsin Powder (25 Gm) 1690 Carbol Fuchsin (125 Ml) 1691 Carbolic Acid 500Ml 1692 Chemical Indicator 1693 Concave Slide 1694 Conical Flask 500Ml 1695 Crystal Violet (125 Ml) 1696 Cyto Brush With Spatula (100 Piece) 1697 Glucose Broath 1698 Gram Iodine Solution (125 Ml) 1699 Haematoxylene Stain 1700 Hydrogen Peroxide 3% (500Ml) 1701 Indicator Tape For Steam Autoclave Process Verification 1702 KovacS Indole Reagent (100 Ml) 1703 Lactose Monohydrate (500 Gm) 1704 Leucoreduction Filter 1705 Liquid Broath 1706 Mac Conkey Agar 500Gm 1707 Mac Conkey Broth Double Strength 500Gm 1708 Methylene Blue 25 Gram (Powder) 1709 Motility Test Medium 1710 Mr Vp Medium 500Gm 1711 Muller Hinton Agar 500Gm 1712 Ph Strips 1713 Sulphuric Acid 98.9% (500 Ml) 1714 Xld Agar 500 Gm) 1715 Xylose Lysine (100 Gm) 1716 Young Broath Culture 1717 Alp Kit 1718 Aso Kit 1719 Capillary Tubes For Ct(Pkts) 1720 Cover Slip(Pkt.) Large(Pkts.) 1721 Cover Slip Small (Pkts.) 1722 Crp Kit 1723 Diamond Pencil 1724 Edta Vacutainer 1725 Esr Tube 1726 Filter Paper For Bt(Pkts) 1727 Formalin (Ltrs.) 1728 Glass Slide 1729 Glucostrips 1730 GramS Stain 1731 Hemoglobin Strips/Hemoque 1732 Ketac-Molar 1733 LeishmanS Stain 1734 Lens Cleaner 1735 Levolin Respules 1736 LugolS Iodine 1737 Mgg Giemsa Stain 1738 Pap Smear Spectulla & Cyto Brush 1739 Ph Strips(Pkts.) 1740 Plain Vacutainer 1741 Plastic Container For Urine 1742 Pm Kits 1743 Ra Kit 1744 Rapid Pep Stain Kit 1745 S.Albumin Kit 1746 S.Calcium Kit 1747 S.Protein 1748 Semen Diluting Fluid (Bottles) 1749 Sugar Kit 1750 Suture (10.0) F 3719 Nylon 1751 Toluidene Blue(500Ml.) 1752 Torniquet 1753 Tsh Card 1754 Widal Kit 1755 Zn Stain Kit 1756 Micro Tips Large 1757 Orthotoluedine Solution 1758 Uristic 1759 Lq080 10 Ml Cooked M Medium (10 Ml X 25) 1760 Sterile Individual Packed Cotton Swabs 1761 Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 0-10Ul 1762 Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 0-20Ul 1763 Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 0-200Ul 1764 Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 100-1000Ul 1765 Skirted Pcr Plate (96 Wells) 1766 Sterile Transparent Sealant For Pcr Plate (96 Well) 1767 Pcr Kits For Covid 19 Testing Compatible With Biorad Pcr 1768 Mac Conkey Both Purple Single Strength W/ Bcp Media M 083 1769 Mac Conkey Both Purple Double Strength W/ Bcp Media M/96 1770 Elisa Ns1 Dengue Kit (96 Test) 1771 Auromine - O (Per Gm) Powder 1772 Broom Stick Stirrer(Pkt 100) 1773 Heparin Lithimum Tube 1774 Pernament Marker Pen Black 1775 Methanol 5Ltr 1776 Zip Lock Bag 20X25 Cm 1777 Hydrochloric Acid (Mw36.46 ) 1778 Slide Box (100 Slide Per Box) 1779 Biohazard Symbol (Red) 1780 Phenol Cristal 1781 Cello Tape (5 Cm) 1782 Potossium Permagnent (Kmno4) Cristal 50 Gm 1783 Spirit Lamp 1784 Spirit Alochloic 1785 Squize Bottle (Small) 1786 Squize Bottle (Big) 1787 Ruber Band 1788 Temp. Humidity Meter 1789 Weighinj Scale Degital 1790 Perafilm 1791 Brosile Zar 5 Ltr 1792 Brosile Zar 3 Ltr 1793 Brosile Zar 500 Ml 1794 Mac Conkey Broth Purple Single Strength W/ Bcp (Hi Media M083 1(500Gm.) 1795 Mac Conkey Broth Purple Double Strength W/Bcp (Hi Media M 796 1(500 Gm.) 1796 Ria- Tubes 1797 Plastic Tube With Cap 2 Ml 1798 Plastic Tube For Calcium Test 1799 Bp Apparatus Digital 1800 Bp Apparatus Marcury 1801 Weighinj Scale For Blood Unit 1802 Stethoscope 1803 Dengue Ns1 Rapid Test Card 1804 Dengue Igm+Igg Combo Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
3.
Housing Urban and Rular Development #11162283 AOC
Providing the manpower for electrical preventive and breakdown maintenance Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033for the period of 12 months.- 1 Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033 2 Skill Electrician: 03 Nos per day 3 Semi-Skill Electrician: 03 Nos per day 4 Un-Skill Electrician: 02 Nos. per day 5 Semi-Skill (Lift Operatror cum Attendent): 02 Nos. per day 6 SCOPE OF WORK:-1. The Scope of maintenance of electrical installation includes Routine, Preventive and Corrective Maintenance of L.T. Distribution lines to each floor of all the buildings/ blocks, entire wirings, BDB, PDB, VTPN, LT panels, Feeder Pillar Box, power & distribution cables, fittings & fixtures, Switch Boards, Power and Computer Points, Power outlet of all sorts of Air-conditioning Systems,resetting/ Switching off of Fire detection system during normal operation/ malfunctioning etc., Operation, configuration & repair / replacement of Timers for AC / Compound light, Compound Lighting including high mast, all glow sign and metal sign boards in the campus, Electrical Installations/ distribution up to Switch Board/ Panel of Lift Machine Room & Pump Room and / or Kiosk of Pump for Water Supply system, in the premises of above mentioned site. 7 2. Cleaning & checking of all the fittings & fixtures, Panels, TPN & SPN DBs, SFUs & other Electrical Installations, as well as the Compound Light installations in a regular interval to keep them in a tip-top condition at the cost of the agency and the same must be recorded in log book.3. The checking & repairing of the different types of light fittings, ceiling fans, exhaust fans etc. has to be done by the agency at his own cost (except rewinding of ceiling fans and exhaust fans) including dismantling and re-fixing of the same. (Major materials to be supplied by department). Especially, all the ceiling fans of entire worksite are to be inspected, at least once in 3(three) Months, in respect of Split Pin, Jam nut etc. to prevent unwanted falling of Ceiling Fans, failing which responsibility will be fixed up upon the agency. Split Pin, once taken out from the installation should not be re-used under any circumstances. Required number of Split Pin and Jam nut should be provided by the agency at their own cost. Building wise Fan register should be maintained as per Performa provided by the department, wherein each and every details of checking, replacement of spares, repairing etc. should be recorded against individual fan and every record should be signed by the attending Electrician / responsible person of the agency, duly countersigned by the concerned J.E. and A.E. 8 4. Measuring of various electrical parameters e.g. Current, Voltage, Temperature of different L.T. panel board, BDBs, Main switches etc., test of Insulation Resistance, Earth Resistance etc. are to be carried out every month and test results are to be recorded in Log book (preventive maintenance). Thermal Imaging Scanner should be used for measuring temperature of electrical equipment regularly to find out any abnormalities and printout of thermal image with date and time stamp should be provided to the concerned J.E. and A.E. In case, any abnormal reading is noticed, the same should be rectified/set right immediately by taking prompt, appropriate & effective measures/actions in consultation with concerned AE&JE. Thermal image should also be taken after rectification. The engaged agency will supervision overall maintenance works and examine Logbooks for any abnormality and sign the Logbook accordingly5. Switching On/Off of the common service lighting e.g. compound, corridors, staircases etc. and AC machines, Light, Fan etc in closed room like Library, Store, OPD, OT or these are not run beyond Office hours or off day will be the responsibility of the agency. 6.Cleaning of Sub-station rooms,LT Panel rooms,operation of HT switch gear & resetting the protective rekeys in case of any fault occurred will be the responsoibilty by the agency . 9 7. Operation of DG sets & checking and maintenance of AMF panel, Checking of Battery, checking of fuel level of DG Set, Lubricating oil etc, carrying & pouring of Fuel if necessary and maintaining separate log book for DG Set as per given Proforma. For Operation of DG Sets, experienced and skilled operator should be provided8.Llift operation cum attendent including regular cleaning of lifts etc as per direction of EIC.9. Regular dusting and cleaning of fire detection sensors and others parts including reset of fire alarms. 10 TERMS & CONDITIONS:-1. The agency has to depute manpower as directed by the EIC carrying out the maintenance work smoothly with due regard to the safety.Category of Staff:- i) Skilled Electrician --03 (Three) Nos per day ii) Semi-Skill Electrician--03(Three) Nos. per day iii) Un-Skill Electrician: 02 Nos. per dayiv) Semi-Skill (Lift Operatror cum Attendent): 02 Nos per day 11 2. The Maintenance Personnel, deputed by the agency havingvalid Voter Identity/ Adhaar Card and should possess valid Workman Permit/ License, as mentioned below, issued by Directorate of Electricity, Govt. of West Bengal.Category of Maintenance Personnel Mandatory Requirementa. Skilled Electrician Having Electrical/ Workman Permit i(b), ii & iv issued by Directorate of Electricity, West Bengal.b. Semi-Skilled Electrician Workman Permit i(b) and (ii) issued by Directorate of Electricity, West Bengal.c. Un-skilled Personnel/ Helper Basic knowledge of Electrical works.Also the Superviser of the company should have valid SCC Parts 1,2,3,4,5,6A,7A,7B ,9,11,12. 12 3. Agency must have to submit mandatorily the list of staff mentioning their Name, contact Mobile No., category, along with photo copy Valid Workman Permit, proper identity and address proof etc, in writing to the concerned JE & AE before commencing the work. All the photocopy should be attested and authenticated by the Agency.4) The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the Maintenance Staffs deployed including substitutes.They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE.5) The agency will maintain shift wise attendance register at call center to record the attendance of the staffs on duty which will be authenticated/ verified by the concerned Junior Engineer/ Officer- in-charge. 13 6) The agency shall have to prepare a Duty Roster of the Maintenance Staffs at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE and one copy should be available at the call centre.7)The agency will have to provide proper uniform for his maintenance staff at his own cost and clour of the dress will be decided by the EIC. No staff will be allowed for performing duty without proper uniform. 8) The agency, and all the electricians deputed at worksite must have Mobile Nos. and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay. 14 9) The agency has to provide one GPS activated smart phone dedicated for call center. The cost of the handset and running cost i.e. phone bills have to be borne by the agency. No claim of payment against any telephone bill will be entertained by this department.10) The agency should have a close watch on the attendance of the Maintenance Staffs. In case of absence of any Maintenance Staffs, the agency shall have to arrange for suitable alternative within an Hour, failing which, the charges for that day will be deducted from the bill of the agency on pro-rata basis.The Executive Engineer,Electrical Constrution Division ,P.W.D. reserves the right to terminate the contract in case of absence of Maintenance Staffs for more than three consecutive days, without showing further reason. 15 11) In case of any Accident and or physical illness of the staffs of the agency, while on duty, no claim will be entertained by this department and all responsibilities thereof should be shouldered by the agency only. Minimum wages as per existing Labor Act should be paid to the Electrician(s) and Helper(s)12) The agency shall have to provide 500V Megger, Digital Multi meter, Earth tester and all other requisite tools and tackles sufficient for checking, testing and recording of health of all electrical installations. Other tools & tackles e.g. Crimping Machine, Line Tester, Screw Driver, Pliers, Stripper, Sockets of some common sizes etc. should also be available at site, in sufficient quantities, free of cost, under disposal of their maintenance staff.Deployed employee by the agency should have sufficient knowledge to operate The Thermal imaging Scanner or to be used by the direction of Assistant Engineer/ Junior Engineer.13) The space for sitting accommodation for the staffs of the agency inside worksite premises will be provided by the competent authority. 16 14) All the maintenance staff of the contractor should have proper & constant vigilance and check that, there is no sign of heating-up, burning smell, discoloration or sparking at any of BDBs, panel boards, rising main etc. due to overloading or loose termination. Care should be taken to check any highly unbalance in loading at any point.15) In case of power failure or development of any unfavorable situation the agency will have to communicate with the concerned Power Supply Company authority and extend help or cooperation to said authority in restoration of power supply. Meanwhile the agency will have to operate the switching mechanisms of interconnections among available sources at suitable locations to maintain power supplies at important locations by monitoring and/ or restricting electrical loads in consultation with the concerned Junior Engineers & Assistant Engineer.16) Routine checking and preventive maintenance and breakdown maintenanceof the electrical installations has to be carried out by the agency maintaining a register under signature of respective Junior Engineer and Assistant Engineer with a view to ensure uninterrupted power supply within worksite campus. 17 17) Materials required as replacement during maintenance of electrical installations e.g. Lamps, SFUs, SPNDB, TPNDB, Cables etc. will be supplied by the Department for which requisition of Materials, signed by the authorized representative of the agency, should be submitted to the concerned JE (Electrical) well in advance. A separate material stock register should be maintained by the agency where entries related to Issue, Consumption & present stock position of Materials should be made. However auxiliary items like fuse wires, screws, nuts, bolts, washers, insulating tape, Split pins of Ceiling Fans, dusters etc. will have to be supplied by the agency at his/ their own expense.18) The agency shall have to deposit all dismantled unserviceable materials such as fused lamps, defective condensers, starters, and timers, MCBs etc. to the concerned Section Office or any other locations within worksite premises by the agency by its own laborers / arrangements / tools and tackles as per the direction of the Assistant Engineer/ JE concerned. Fresh materials will be issued against respective defective materials. No materials should be taken out of the maintenance site without the permission and necessary challan of the site-in-charge/JE 18 19) Any major shut down or fault should be brought to the notice of JE/AE immediately in writing and over telephone for further course of action. The agency will also have to attend emergency calls immediately at the site with staff, tools etc. on demand. 19 20) In case of any breakdown caused by cable fault etc., if situation demands the agency will have to restore the power supply temporarily either with the materials available with this department or arranging the same temporarily and safely at his own cost till completion of original restoration work.21) Building wise Log book is to be maintained for Preventive Maintenance & Cleaning and Corrective Maintenance of Electrical equipment except Fan as per direction of E.I.C. Separate Building wise Register is to be maintained for Ceiling Fans. The daily record of the Log book is to be signed by the responsible person and verified & signed by concerned JE & AE and photocopy of the same should be sent to the Executive Engineer concerned through proper channel at the time of submission of bills. The Logbooks should be available at Call center and should be produced on demand. 20 21) The agency should be responsible for any damage in the installation due to mishandling or mal- operation by its staff and shall be liable for rectification / replacement, as the case may be, of the damaged installation/ equipment within time frame to be fixed by concerned A.E., failing which the said rectification/ replacement of affected equipment/ installation would be executed by external agency and the cost thereof would be recovered from the bill and the accused staff should be replaced immediately.22) Bills should be submitted quarterly with the certification of satisfactory performance of the concerned JE and AE. Photocopy of Logbook and Attendance Register should also accompany the Bill. Payment should be made as per PWD norms. 21 23) Any fault of electrical installations starting from LT supply end (except the installations of Power Supply Company) to light, fan, call bell, plug points etc. i.e. LT cables and all sub-panels, distribution boards, main switches, earthing attachments, compound lights etc. has to be detected, attended and restored by the agency by its own man power with the help of the materials(cables, main switches, DBs, wires, HRC fuses etc.) available from this department or as per the terms & conditions of this contract. 24) If any kind of incapability & negligence are noticed in observing all the above-said terms & conditions causing inconveniences to public service, is subject to unilateral penalty, be it detected on the spot or thereafter (even after payment). This Department also reserves the right to deduct the cost from the bills of the contractor on pro-rate basis as determined by the Engineer –In-Charge for any shortfall in observing above T&C. In that case, the above- said contract may be terminated without issuing any notice and Stringent & punishable action may be taken against the contractor. 22 25) The technitian of the agency should capable of Casing -caping /rigid conduit wiring to overcome the emergent situation .25) The contract may be terminated with one months’ notice on either side (both agency and tender awarding authority) . 26) At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .27) Any upcoming / Ongoing project, which will be completed within stipulated period of Maintenance contract, automatically will come under maintenance contract .28) All the log-books should be available at the call center and to be produced to the Office of the AE/ JE on demand. 29) This Maintenance contract covers all the buildings, blocks, outdoor electrical gadgets within the premises ofTechnician Studio, Kolkata-700033 23 TERMS & CONDITIONS FOR OPERATION OF LIFTS:- 24 1. The agency has to depute manpower as directed by the EIC carrying out the lift operation smoothly with due regard to the safety.Category of Staff:- Semi-Skill (Lift Operatror cum Attendent): 02 Nos. 25 2. Day to day Attendent -cum -operation of passenger lift foras directed by the EIC.3. The lift operator/attendant should have a sound knowledge with valid lift operator license issued by the Licensing Board, Govt. of West Bengal.4. The operator/attendant should be obliging dutiful and polite to all while on duty. In case any irregularities of duty or complain against the operator/attendant if noticed, would be withdrawn forthwith and shall be replaced by new operator.5. The report is to be submitted periodically about the working of lift incl. all safety devices and Governor to the concerned JE/AE. 26 6. Agency must have to produce the list of the staff mentioning their Name, contact Mobile No.in writing with proper identity and address proof & their Valid lift operator license issued by the Licensing Board, Govt. of West Bengal along with photo copy to the concerned JE & AE before commencing the work. This should be treated as mandatory.7. The agency will have to provide proper dress for his staff and color of the dress will be decided by this department. No staff will be allowed for performing duty without proper dress.8. The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the operation Staffs deployed including substitutes. They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE 27 9. The agency shall have to prepare a Duty Roster of the operation Staff at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE.10. The agency must have separate contact telephone numbers with Mobile Nos. for his office and Supervisor deputed at worksite so that the agency may be communicated in case of any urgency and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay.11. The lift enclosure to be kept clean (not sweepers works) regularly by the operator 28 12. The operational work of the lift is to be supervised directly under the supervision of technical staff of the contractors under the direct control of JE/AE concerned. The contractor shall be responsible for any damage to the lift due to mishandling; loss will be recovered from the contractors bill as per direction of EIC.13. The Log Book recording regarding functioning and breakdown of the lift is to be maintained at site by the contractor under supervisions of JE concerned. If any kind of trouble arises, it should be brought to the notice of JE, AE concerned immediately. The JE/AE would put their signature on log book making note on performance. 29 14. In case of any absence of operator, the lift is to be made operative within 2 hours by placing the new operator. In case of absence prorate deduction will be made from the contractors bill and the contract may be terminated if it exceeds 3 (three) days. In this respect Executive Engineer’s decision will be final.15. This department would not be held responsibility for any accident of the liftman on duty for any reasons. The contractor or their lift operators on duty would not claim any compensation in any shape from this department for such accident. 30 16. The Executive Engineer,Electrical ConstructionDivision, P.W.Dte. would have sole authority to cancel the contract without assigning any reason with a notice of one month only.17. Any conditional quotation offered would not be accepted.18. Any quotation offered with price variation clause would not be accepted.19. The payment will be made monthly/quarterly on submission of bill in triplicate by the agency with satisfactory report regarding performance by the concerned JE/AE. Copy of log book has to be enclosed with the bill. 31 20. Persons entrusted by the agency for operation of lift should wear photo Identity Card during duty hours.21. Documentary evidence in support of payment of minimum wages as per Labour Act to be produced to the Principal Employer i.e. Executive Engineer, Electrical Construction Division, P.W.Dte. in-charge of works.22. Rescue operation is in the scope of agency in case of exigency arises out of lifts getting stopped in between landing floors with passengers inside cage.23. No claim towards cost of uniform, PPE e.g. Hand Gloves, Mask, Goggles, protective body- ware etc. for the maintenance staffs should be entertained by this department. However, if any such equipment/ dress is available from the Hospital Authority for their statutory requirement, the same would be provided. BUT IN NO CASE IT SHOULD BE ENTERTAINED AS MANDATORY CLAIM.24.At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .
Contract Date: Mar 09, 2026 Contract Value : 14.46 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
4.
Housing Urban and Rular Development #11147206 Price Bid
Tender for Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within Any Metres Lead Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Random Rubble Masonry With Hard Stone In Super Structure Above Plinth Level And Upto Floor Five Level , Including Leveling Up With Cement Concrete 1:6:12(One Cement : Six Coarse Sand : Twelve Graded Stone Aggregate 20 Mm ( Twenty Millimetre ) Nominal Size) At Window Sills, Ceiling Level And The Like.Cement Mortar 1:6 (One Cement : Six Coarse Sand) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , 20 Mm ( Twenty Millimetre ) Cement Plaster Of Mix : 1:6 (One Cement: Six Coarse Sand) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Finishing Wall With Weather Proof Exterior Grade Emulsion Of Approved Design (Apexultima) Or Its Equivalent On Undecorated Wall Surfaces (Two Coats) To Give An Even Shade And Final Finish After Throughly Cleaning The Surface To Remove All Dirt, Dust And Other Foreign Matter Etc Including Sand Paper Smooth Complete Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Including Cost Of Binding Wire Up To Any Level Above Plinth Level Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Excavating, Supplying And Filling Of Local Earth (Including Royalty) By Mechanical Transport Upto A Lead Of Any Kilometre Also Including Ramming And Watering Of The Earth In Layers Not Exceeding 20 Cm ( Twenty Centy Metre ) In Trenches, Plinth, Sides Of Foundation Etc. Complete Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Steel Work In Built Up Section Trusses And Framed Work Including Hosting Fixing In Position And Applying A Priming Coat Of Red Lead Paint As Per Direction Of Engineer-In-Charge.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing Stainless Steel Railing Of Apporved Shade & Design With 14 ( Forteen ) Gauges ( Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, (For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.).:Mounted Square Balluster System With Horizontal Members(Dt53-1-163)Of Tata Steel / Appolo , Kich Or Its Equivalent. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In Charge : 80 Mm ( Eighty Millimetre ) Thick cement concrete Paver Block Of M-30 Grade With Approved Color Design And Pattern. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Stone Soling/Boulder Filling Dry Hand Packed In Under Floor Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand) : 4 Graded Stone Aggregate 20 Mm Nominal Size) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Excavation In Foundation Trenches Etc. In Earth Work In All Kinds Of Soils Such As Pick Work , Jumper Work, Pick Work,Pick Jumper Blasting Work, Blasting Work In Soft And Hard Rock Conglomrate Rock Or Saturated Soil And Its Intermediate Classification Of Soil Including Chiseling/Wedging Out Of Rocks (Where Blasting Is Prohibited) And Pumping Or Bailing Out Of Watering/Dewatering Upto Any Lift Stacking The Excavated Soil Clear From The Edge Of Excavation And Then Returning The Stacked Soil In Layers When Required Into Plinth Sides Of Foundations Consolidation Each Deposited Layer By Ramming And Watering And Then Disposing Of All Surplus Excavated Earth Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Cement Concrete In Retaining Walls, Return Walls,Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, Stringor Lacing Courses, Parapets, Coping, Bedblocks, Anchor Blocks,Plain Window Sills, Fillets,Sunken Floor Etc.,Upto Floor Five Level,Excluding The Cost Of Centering, Shuttering And Finishing : 1:3:6 (One Cement : Three Coarse Sand : Six Graded Stone Aggregate 20 Mm ( Twenty Millimetre) Nominal Size Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Cement Concrete 1:6:12 (One Cement: Six Sand : Twelve Graded Stone Aggregate 40 Mm ( Forty Millimetre) Nominal Size) And Curing Complete Excluding Cost Of Centring And Shuttering In Foundation And Plinth Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Kota Stone Slab Flooring Over 40 Mm ( Forty Millimetre) (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1:4 (One Cement : Four Coarse Sand) : 25 Mm ( Twenty Five Millimetre) Thick Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing Ornamental Ready Made Piller With Anarial Design Within All Leads And Lifts And As Per Hp.Pwd. Specifications Of 1990 Volume - I Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing 0.60 Mm ( Zero Point Sixty Millimetre) Thick Prepainted Steel Sheet Roofing, With Hot Dipped Metallic Zinc Coated Sheet With Top Coat Of Regular Modified Polyster (Rnp) Organic Coating Of 20 ( Twenty ) Microns Over 5 ( Five Microns Primer Coating To Back Coat Of Polyster Of 5 Microns Over 5 ( Five) Microns Primer Coating I/C Fixing With Prepainted Iron J Or L Hooks, Bolts And Nuts 6Mm Dia Metre With Prepainted Limpet And Rubber Washers Complete With All Accesoriees As Requiredincluding Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing Prepainted Ridges Or Hips 60 Cm (Sixty Centimeter) Overall With 0.60 Mm (Zero Point Sixty Millimeter) Thick Preprinted Steel Sheets In Roofing With Hot Dipped Metallic Zinc Coated Sheets With Top Coat Or Regular Modified Polyester Organic Coating Of 20 (Twenty) Microns Over 5 (Five) Microns Primer Coating + Back Coat Of Polyester Of 5 (Five) Microns Over 5 (Five) Microns Primer Coating Including Fixing With Preprinted Iron J Or L Hooks, Bolts & Nuts 6Mm(Six Millimeter) Dia And Preprinted G.I. Limpet And Bitumen Washers Complete With All Accessories As Required Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Steel Work In Built Up Section Trusses And Framed Work Including Hosting Fixing In Position And Applying A Priming Coat Of Red Lead Paint As Per Direction Of Engineer-In-Charge.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Fixing Of Ornamental Bench As Per Hp.Pwd. Specifications Of 1990 Volume-I Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/ 10 Sqm ( Zero Point Ninety Liter / Ten Square Metre ) Over An Under Coat Of Primer Applied @ 0.80 Ltr/ 10 Sqm ( Zero Point Eighty Liter / Ten Square Metre )Of Approved Brand And Manufacture Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Supply Installation Testing & Commissioning Of Boom Barrier Of 4 Mtr ( Four Metre) Length Of Boom Arms. Galvanised And Ral Painted With Buil In Control Panel With Intensive Use. Manual Open / Close Buttons And Automatic Closing Ir Device Complete With Ground Loop Detection Board (For Entrance And Exit To The Main Building),100% Duty Cycle.High Intensive Use Dc Barrier. 180-200Nm Operating Torque For. 2 Sec Open/Close Time . Motor Current Draw : 12A. Max Motor Power: 300W.Max Opening : 90 Degree.Ip54. Inter-Changeable Barrier( Left To Right And Vice Versa). Ampereomatic Feature For High Safety In Case Of Failure Of Safety Device. Complete As Required As Per Given Technical Specification. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Supply Installation Testing & Commissioning Of Portable Spike Barieer Tyre /Killer Suitable To Work On Manual Operation .The Main Frame Is Made Of 6Mm Thick Flat Aluminum Strip Which Made It Corrosion Resistant,Strong And Light In Weight For Easy Portability & Long Durability. Other Details Are As Below, A. Portable Tyre Killer - 4 Mtr. B. Edge Of Spike - 10Mm, C. Height Of Spike - 60Mm, D. No. Of Spikes - 85 Nos. E. Total Weight : 7 Kg. (Approx.) F. No. Of Wheels In Packing Box - Two Etc. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto Any Metre And Lift Upto Any Metre . All Kinds Of Soil Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding Any Centyme Tre ) In Depth, Any Metre In Width As Well As Ten Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto Any Metre And Lift Upto Any Metre , Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/ Manual Means Over Areas (Exceeding Any Cemntimetre In Depth, Any Metre In Width As Well As Ten Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto Any Metre And Lift Upto Any Metre , Ordinary Rock Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding Any Centy Metre In Depth , Consolidating Each Deposited Layer By Ramming And Watering, Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Extra For Every Additional Lift Of Any Metre Or Part Thereof In Excavation / Banking Excavated Or Stacked Materials. All Kinds Of Soil Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (One Cement : Four Coarse Sand) : Eight Graded Stone Aggregate 40 Mm ( Forty Mellimetre ) Nominal Size Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (One Cement : Two Coarse Sand) : Four Graded Stone Aggregate 20 Mm ( Twenty Mellimitter Nominal Size) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge.(Note :- Cement Content Considered In This Item Is @ 330 Kg/Cum.( Three Hundred Thity Kilo Gram / Cubic ) Excess/ Less Cement Used As Per Design Mix Is Payable/Recoverable Separately). All Works Upto Plinth Level Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.Thermo-Mechanically Treated Bars Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : Suspended Floors, Roofs, Landings, Balconies And Access Platform Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Edges Of Slabs And Breaks In Floors And Walls: Under 20Cm ( Twenty Centimetre ) Wide. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Supplying And Stacking At Site. Good Earth Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Integral Cement Based Treatment For Water Proofing On Horizontal Surface At All Depth Below Ground Level For Under Ground Structures As Directed By Engineer-In-Charge And Consisting Of : (I) Ist Layer Of 22 Mm To 25 Mm ( Twenty Two Millimetre To Twenty Five Millimetre ) Thick Approved And Specified Rough Stone Slabover A 25 Mm ( Twenty Five Millimetre) Thick Base Of Cement Mortar 1:3 (One Cement : Three Coarse Sand) Mixed With Water Proofing Compound Conforming To Is:2645 In The Recommended Proportion Over The Leveling Course (Leveling Course To Be Paid Separately). Joints Sealed And Grouted With Cement Slurry Mixed With Water Proofing Compound. (Ii) 2Nd Layer Of 25 Mm ( Twenty Fiver Millimetre) Thick Cement Mortar 1:3 (One Cement: Three Coarse Sand) Mixed With Water Proofing Compound In Recommended Proportions. (Iii) Finishing Top With Stone Aggregate Of 10 Mm To 12 Mm ( Ten To Twelve Millimetre) Nominal Sizespreading @ 8 ( Eight ) Cudm/Sqm Thoroughly Embedded In The 2Nd Layer. Using Rough Kota Stone. Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Laying Integral Cement Based Treatment For Waterproofing On The Vertical Surface By Fixing Specified Stone Slab 22 Mm To 25 Mm ( Twenty Millimetre)Twenty Five Millimetre) Thick With Cement Slurry Mixed With Water Proofing Compound Conforming To Is:2645 In Recommended Proportions With A Gap Of 20 Mm (Minimum) Between Stone Slabs And The Receiving Surfaces And Filling The Gaps With Neat Cement Slurry Mixed With Waterproofing Compound And Finishing The Exterior Of Stone Slab With Cement Mortar 1:3 (One Cement : Three Coarse Sand ) 20 Mm Thick With Neat Cement Punning Mixed With Waterproofing Compound In Recommended Proportion Complete At All Levels And As Directed By Engineer-In-Charge : Using Rough Kota Stone Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Providing And Placing In Position Suitable Pvcwater Stops Conforming To Is:12200 For Construction / Expansion Joints Between Two Reinforced Cement Concrete Members And Fixed To The Reinforcement With Binding Wire Before Pouring Concrete Etc. Complete : Dumb Bell With Central Bulb (180 Mm ( One Hundred Eighty Millimetre ) Wide, 8 Mm ( Eight Millimetre ) Thick) Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Making Soak Pit 2.5 M ( Two Point Five Metre ) Diameter 3.0 ( Three Point Zero Metre) Deep With 45 X 45 Cm ( Forty Five X Forty Five Centimetre ) Dry Brick Honeycomb Shaft With Bricks And S.W. Drain Pipe 100 Mm ( One Hundred Millimetre ) Diameter , 1.8 M ( One Point Eight Metre) Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst. , Construction Of Pre-Fabricated Cabin Size (12.00X5.00X5.00)Mtr Roof Hut Shape As Per Dreawing. Specifications:-A) Outer Wall 50Mm Thick Wall Puf Insulated Panel.B) Roof Panel (30/70)Mm Thick Puf Panelc) Door And Window (As Per Drawing) Upvc.D) Ppgi Flashings (U-Channel & Corners). E) Hardware & Accessories.F) Erection Of Wall And Roof Panel.G) Tile Flooringh)Pvc Ceilingincluding All Civil Work Required I.E Foundation, Ooting, Plinth Beam Etc, Office, Toilets,Electrical Work ,Hvac,Fire Ighting,Plumbing & Sanitation,Earthing,Over Head Tank 5,000 Ltr, Septic Tank Etc As All Required Work Completed Including Carriage Of Materials With-In All Leads And Lifts And Other Incidental And As Per Entire Satisfaction And Direction Of Engineer-In-Charge. The Rate Is Including Octroi, Royality, Malkana, Toll-Tax Or Any Other Imposed By The Government But Excluding Gst.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Himachal Pradesh View Result →
5.
Defence #11110287 Technical Bid
Tender For Provision Of Md Accommodation For 16 X Officer At Ferozpur Mil Stn (Tender-1) (Tender Id : 2025_Mes_742975_2)- 3 Lump Sum Price Worked Out By The Contractor For Building Work As Listed In Schedule A Part-I Brought Forward From Serial Page No.30. 4 Lump Sum Price Worked Out By The Contractor For Site Clearance And Earth Works As Listed In Schedule A Part-Ii Brought Forward From Serial Page No.31. 5 Lump Sum Price Worked Out By The Contractor For Internal Electrification Works As Listed In Schedule A Part-Iii Brought Forward From Serial Page No. 32, 33(R) To 35(R). 6 Lump Sum Price Worked Out By The Contractor For Internal Water Supply Works As Listed In Schedule A Part-Iv Brought Forward From Serial Page No. 36(R). 7 Lump Sum Price Worked Out By The Contractor For Sewage Disposal Works As Listed In Schedule A Part-V Brought Forward From Serial Page No. 37. 8 Lump Sum Price Worked Out By The Contractor For Area Drainage Works As Listed In Schedule A Part-Vi Brought Forward From Serial Page No. 38. 9 Lump Sum Price Worked Out By The Contractor For Compound Wall Fencing And Gate Works Listed In Schedule A Part-Vii Brought Forward From Serial Page No. 39 & 40. 10 Lump Sum Price Worked Out By The Contractor For Road, Path & Culvert Works As Listed In Schedule A Part-Viii Brought Forward From Serial Page No. 41 & 42. 11 Lump Sum Price Worked Out By The Contractor For External Water Supply Works As Listed In Schedule A Part-Ix Brought Forward From Serial Page No. 43. 12 Lump Sum Price Worked Out By The Contractor For External Electrification Works As Listed In Schedule A Part-X Brought Forward From Serial Page No. 44 To 47. 13 Lump Sum Price Worked Out By The Contractor For Dg Set Work As Listed In Schedule A Part-Xi Brought Forward From Serial Page No. 48. 14 Lump Sum Price Worked Out By The Contractor For Lift Work As Listed In Schedule A Part-Xii Brought Forward From Serial Page No.49. 15 Lump Sum Price Worked Out By The Contractor For Fire Fighting, Fire Alarm & Detection System Work Works As Listed In Schedule A Part-Xiii Brought Forward From Serial Page No. 50 & 51. 16 Lump Sum Price Worked Out By The Contractor For Lightening Protection Work As Listed In Schedule A Part-Xiv Brought Forward From Serial Page No. 52. 17 Lump Sum Price Worked Out By The Contractor For Rain Water Harvesting Works As Listed In Schedule A Part-Xv Brought Forward From Serial Page No. 53 & 54(R). 18 Lump Sum Price Worked Out By The Contractor For Solar Water Heater Work As Listed In Schedule A Part-Xvi Brought Forward From Serial Page No. 55. 19 Misc Items Of Works (To Be Quoted By Bidder) As Listed In Schedule A Part-Xvii 20 Internal Water Supply Works 21 Supply & Fixing 15Mm Cp Brass Health Faucet (Hand Shower), Inlet Length 100Mm Fixed To Angle Valve With And Including Decorative Choice Flexible Pipe, Wall Hanger Etc Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. 22 Supply & Fixing 15Mm Bore Fancy Type Central Hole Single Lever Basin Mixer With 450 Mm Braided Connection Pipe Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed.Make Cera Model No F2013451 / Jaquarqqp‐Chr‐7167Bpm / Roca T5A8497Ca1 / Kohler Model No. K‐ 27484In‐4‐Cp 23 Supplying And Fixing Two Way Bib Cock With Single Handle And Wall Flange 15Mm Dia, Fancy Type Chromimum Plated Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. Make Cera Model No F2013163 / Jaquar Lyrchr‐38041 / Kohler Model No K‐16094In‐4‐Cp / Roca Model No.Rt5A937Aca1 24 Supply & Fix 15 Mm Bore Sink Mixer With Swinging Spout (Wall Mounted) With 150Mm Long Swivel Spout Connecting Legs & Wall Flanges Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. Make Cera Model No F2013501 / Jaquar Model No Ari‐Chr‐39165 / Kohler Model No. K‐20591In‐4‐Cp / Roca Model No. Rt5A8497Ca1 25 Supplying And Fixing Wall Mounted Bib Cock, Chromium Plated, With Wall Flange & Aerator (Cera Cat No. F1015151) / Jaquar‐ 16094In‐4‐Cp/ Roca Rt5A937Aca1 / Kohler Model No 16093In‐4‐Cp Including All Necessary Fittings For Fixing With Pipe Complete All As Specified And Directed. 26 Supplying And Fixing 32 Mm Upvc Ball Valve With Screwed Both Ends Pipe And Fixed All As Specified And Directed 27 Internal Electrification Works 28 Material & Labour For Point Wiring With 1.5 Sqmm, Pvc Insulated But Unsheathed, Stranded Copper Conductor Single Core Frls Cable, Is-694 Marked, Drawn Through And Including Non Metallic Rigid Pvc Concealed Conduit Medium Grade 20Mm Dia (Minimum) Or Higher Size As Specified And Cutting Chasing On Wall Complete With All Pvc Conduit Accessories Such As Socket, Elbow, Junction Box, Bell Mouth, Reducer, Bend And Flexible Conduit Etc/ Fittings Isi Marked For Modular Fittings And Brass Screws And Cup Washers Including 1.5 Sqmm Stranded Copper Conductor Pvc Insulated Frls Cable Green In Colour As Continuous Earth Conductor Connected To Common Earth And Earth Dolly With All Accessories Complete All As Specified And Directed. Note:- Cost Of Metal Boxes And Modular Accessories Like Cover Plates Will Be Paid Seprately In Respect Items (A) Fan Point/ Exhaust Fan Point /One Light Point/Bell/Buzzer Controlled By One Switch/Bell Push. 29 (B) One Modular Socket Outlet 5 Pin 5 Amp Controlled By One, One Way Switch On Same Board. 30 (C) One Modular Socket Outet Point 5 Amps On The Independent Board. 31 (D) One Light Point Controlled By Two Nos Of Two Way Switch. 32 All As Ser Item 4.02 Here In Before But With 2.5 Sq Mm Wire And Earth Wire Of 2.5 Sq Mm For 3 Pin 15 Amp Modular Type Socket Outlet. 33 Supply And Fix Modular Metal Flush Box Made Out Of Gi Sheet, Thickness Not Less Than 1.2Mm With Earthing Terminal, 8 Module Complete All As Specified And Directed. 34 Supply And Fix Modular Metal Flush Box Made Out Of Gi Sheet, Thickness Not Less Than 1.2Mm With Earthing Terminal, 12 Module Complete All As Specified And Directed. 35 Supply And Fix Modular Dummy Plate Complete All As Specified And Directed. 36 Supply And Fix Led Energy Efficient Led Bulb B22, 9 Watt Complete All As Specified And Directed. 37 Supply And Fixing Vtpn Db’S 4 Way, Double Door, 415V, Ip43, Suitable Size And Length Of Crca Steel Sheet, Dust Protection Duly Powder Painted Including Factory Fitted Suitable Size Copper Bus Bar, 01 No Of Mccb Tpn As Incomer And 04 Nos Tp As Outgoing With Neutral Link, Earth Bar, Din Bar For Mounting Mcb And Blanking Plate A Complete All As Specified And Directed. Note:- Mcb Shall Be Measured And Paid For Separately. 38 Supply And Fixing Tv Socket And Connector Complete With All Necessary Fittings All As Specified And Directed. 39 Material & Labour For Wiring With 1100 Volt Grade One Single Core Frls Wire Pvc Insulated And Unsheathed Cable With Stranded Copper Conductor 1.5 Sqmm (For Inverter) Drawn Into Pvc Conduit With All Accessories Fixed Concealed Complete All As Specified And Directed. 40 Supply And Fix Led Tube Light Fitting In Extruded Aluminium Housing For All Purpose Surface And Wall Mounted With Single Side Connection Aluminium Led Batten With 125 Lum/Watt System Efficancy Polycarbonate Housing And Integrated Electronic Driver Of Capacity 20 W, Four Feet And Connection With Pvc Insulalted Twin Core 23/0.0076 Twisted Copper Cable From Ceiling Rose To Tube Light Fitting Complete All As Specified And Directed. Make: Havells Cat Part No. Enduralinearprobs20Wled865Spcssind Or Equivalent Make Of Bajaj/Crompton/ Philips. 41 Supply And Fix Wall/Ceiling Mounting Led 9/10 Watt Tube Light Fitting In Extruded Aluminium Housing And Integrated Electronic Driver Complete With All Acessories 1X9 Watt Led, With Cct Of 6000K Suitable For Domestic Application, 240 Volts, 50 Hz, And Internally Pre-Wired With 1.5 Sqmm Twin Twisted Flexible Cable Copper Conductor And Connection Complete All As Specified And Directed. Make: Havells Cat Part No. Lumilinebs9Wled865Spcwh Or Equivelent Make Of Bajaj/ Crompton/ Philips. 42 Supply And Fix Bldg Street Fitting Made Up Of Pressure Dai Cast Aluminum Housing With High Efficiency Leds As A Lighting Source And Lens Embedded Pc Cover Having Top Oppening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07, Cct 5700 K, Of Wattage 25 Watt Including Connection With 3 Core Pvc Insulated Overall Sheathed Flexible Cable With Multi Stranded Copper Conductor Of Size Not Less Than 1.0 Sq Mm From Celing Rose To Fitting Terminal All As Specified And As Directed. Make :- Havells/ Bajaj/ Hpl/Philips 43 Supply And Fix Gi Pipe Bracket Made Of Gi Pipe Light Grade 32Mm Dia And Bend To Shape 1.5 Mtr Long Ms Clamp Made Out Of Ms Flat Iron Of Size 32Mm X 3Mm With Nut And Bolts Washer Complete Including Drilling Of Holes For Nut And Bolts Etc Complete All As Specified And Directed. 44 Supply And Fixing Decorative Type Led Wall Lights Fitting 08/09 Watt, 220V, Suitable For Led Lamp B22 9 Watt Complete All As Specified And Directed. Make: Havells Cat No Lhfoecce1Tz1O014 Or Equivalent Philips/Cg 45 Supply And Fix Kitchan Wall Fan 300 Mm Sweep, 1350 Rpm, Of Elegantly Designed Fan Base In Round Shape For 50 Cub Mtr/Min Air Delivery And Minimal Noise Levels With Pull Code Control For Speed & Oscillation Upto 90 Degree Total Flexibility, Double Z Shielded Ball Bearing, Sturdy Brazed Wire Guards With Power Coating Ensures Corrosion Resistance Conforming To Is 2997-1964 Complete All As Specifed And Directed. 46 Supply And Fix Kitchan Chimney Dry Heat Auto Clean Technology Stainless With Air Outlet 150 Mm, Steel Finish Front Matte Black Glass Panel With Digtal Display Touch Control Panel With 3 Speed Gesture Motion, Heavy Duty Baffle Filters, Minimium Air Flow 1180 M3/H Energy Saving Led Light Of Suitable Wattage, Copper Winding Bldc Motor, 62Dba Max Noise Level And Voltage 220-240 V/50 Hz Including Making Hole In The Wall And Making Good The Distubed Surface Of Wall Including All Accessories All As Specified And Directed. Make : Kaff Model No.Sku Nevishc90 Or Eqvt In Hindware/ Faber. 47 Supply, Installation, Testing & Commissioning Of 3-Φ, 4 Wire, Ac Static Direct Connected, Smart Pre-Paid Energy Meters, Isi Marked Of Different Makes As Per Bis-16444, With Communication Technology Including Gprs/Rf/Hybrid (Rf Mesh Network+Gprs)/Any Other Advanced Technology As Per Cea/Trai Regulations) With Current Range 10-60 Amp, 415 V, Accuracy Class 1.0 Uc1 Category And Above Along With In-Built Load Control Switch, Containing Provision For Tod & Rtc, Capable To Define Multiple Tariff Slabs Complete All As Specified And Directed.Meter Should Support The Following Data:- (I) 15 Min Instantaneous Data For Voltage, Current, Power Factor, Power, Cumulative Energy And Frequency, Daily And Monthly Billing Survey For Cumulative Energy And Max Demand(Ii) Meter Should Have Connect / Disconnect Functionality Operable For Mdm/Billing Software And Prepaid Features Would Be Operable For Mdm / Billing End As Per Is: 15959 Part-2.(Iii) Meter Should Support Communication Protocol Through Rf/ 5G/4G/Nb Iot With The Existing Software In Stn All As Required At Site And Directed (Cost Of 5G/4G/Nb Iot Sim With Two Year Recharge Facilities, Mapping, Vending Portal Charges Etc Deemed To Included In Rate Quoted For Meter). (Iv) The Meter Should Support Open Communication Protocol Dlms With The Existing Software.Make: Anchor/L&T/Hpl/Secure.Note:- (I) The Smart Meter Would Be Compatiable With Existing Software/Dcu In Stn.(Ii) The Rate Of Sim As Well As Data Pack Of 24 Months From Date Of Completion For Connectivity Is Deemed To Be Including In The Quated Rates. 48 Supply & Fixing Of Transparent Polycarbonate Meter Box Of Suitable Size With Ip-54 For 3-Φ, 4 Wire, Smart Energy Meter Mentioned Here-In-Above At Sch. Item No. 4.21. The Polycarbonate Meter Box Shall Comply With Is-14772:2000 And Is-11000:1984. It Shall Be Totally Shock Proof, Safe Weater Proof, Rust Roof, Dust Proof, Water Proof, Halogen Free, Silica Free And Having Internally Embeded Gasket Technology, Transparent Hinged Lid And Sealing Provision Including Bakelite Connector, Complete All As Specified And Directed. Make: Anchor By Panasonic/L&T/ Hpl/Secure. 49 Road Works 50 Material And Labour For Preparing Bituminous Surface Of Road And Marking 2.5Mm Thick Hot Applied Thermo Plastic Road Marking Paint Of Approved Colour Providing Retroreflecting Glass Beads @ 250 Gm Per Square Metre As Per Irc-135 With Special Applicator Machine All As Per Manufacturers Instruction Complete All As Specified And Directed. 51 External Water Supply Works 52 Supply And Laying Ductile Iron Pipe Of 100Mm Bore With Spigot And Socket Ends Centrifugally Cement Mortar Lined Complete As Per Is 8329/ 2000 Class K-9 With Including Suitable For Tyton Joint And Jointing Material/ Joints Laid In Trenches Complete All As Specified And Directed.Note ;- Di Specials And Earth Work Shal Be Measured And Paid Seperately. 53 S&F 80Mm Dia Gi Tubing Heavy Grade C Class With All New Connections And Fitting Such As Tee, Elbows, Bend, Reducer, Unions, Short Pieces, Connector Back Nuts, Diminishing Pieces, Caps, Plugs Unions Etc Laid In Threnches Complete All As Specified And Directed. 54 Material & Labour For Valve Pits And Constructing Of Brick Masonary Pits Of Internal Dimensions 900Mm X 900Mm X 900Mm (Bottom Pcc Floor Of The Pit Should Be Minimum 30 Cms Below The Bottom Surface Of Sluice Valve Flange To Provide Sufficient Working Space), Bottom Floor Of The Pit Be Constructed In Pcc (1:3:6) 51 Cms Thick With 20 Mm Stone Aggregate, Inner And Exposed Surfaces And Bottom Floor Of The Pit Should Be Plastered In Cm (1:4) 15 Mm Thick. The Sluice Valve And Other Fittings Should Be Housed In Center Of The Pit. The Verticesof The Pit Should In Right Angle And Champhered. The Top Cover Of The Pit Will Be Made Out Of Ms Sheet Min 2 Mm Thick With Angle Iron Frame Made Out Of Ms Angle 50Mm X 50Mm X 6Mm With Galvanized Steel Hindges Two Nos And Locking Arrangements Duly Painted With Two Coats Of Water Resistant Synthetic Enamelled Paint Over One Coat Of Red Oxide Complete All As Specified And Directed. 55 Material And Labour For Taping From Existing Di 80 Mm To 150 Mm Including Cutting, Jointing, Inserting Tee And Alll Accessories Complete All As Specifed And Directed.Note:- Tee Shall Be Measured And Paid Separately Under Respective Items. 56 External Electrification Works 57 Supply, Install, Testing And Commissioning Of Lt Distribution Panel (Cpri Type Tested ) Cubicle Type Ip-65, Outdoor Type Confirming To Is-61439 Factory Fabricated Prewired Made Out Of 3.15 Mm Thick Crca Sheet Outer & 2 Mm Thick Crca Sheet Inner Of Suitable Size To Accommodate All Accessories/Fittings Compartmentalized In Construction To Accommodate The Incoming/Outgoing Mccb And Tpn Bus Bars And Outgoing Feeders. The Tpn Bus Bars Shall Be Insulted With Colour Coated Heat Shrinkable Sleeve And Shall Be Mounted On Dmc Support. The Incoming As Well As Outgoing Mccbs Shall Have Extension Links Of Current Carrying Cap Not Less Than 1.5 Times The Rated Capacity Of Individual Feeders. The Extension Links Shall Be Supported On Dmc Support Having Provision For Termination Of Incoming And Outgoing Cables. All Extension Links/ Interconnections Shall Be Colour Coated Sleeves. The Cubicle Shall Have Frame Work At Bottom Of Ms Channel Mc 100 Fixed To The Top Of Plateform. The Plateform Of Lt Panel Shall Be Pedestal Type Of Suitable Width And 600 Mm Height Above Ground Level And Minimum 400 Mm Below The Ground Level Constructed With Bricks (Sub ClassB) Work Duly Plastered In Cm 1:3 And Pcc Copping (1:2:4) Not Less Than 50 Mm Thick Over Brick Pedestal With Adequate Opening For Entry Of Cable Complete As Per Manufacture Recommendation And Directed By The Engr-In-Charge. A Detachable Gland Plate Of Thickness Not Less Than 3 Mm Thick Should Be Used At The Bottom For Entry Of Armoured Cable Of Adequate Size Compression Glands, The Panel Shall Be Painting With Powder Coated Finish With Ral 7032 Siemens Gray Structure After Seven Tank Phosphate Treatment Front & Back Opening Type And Fixing 2 Nos Danger Notice Plan With Letter Figures And Conventional Skull Bones In Signal Red Colour And Fixed Front & Back Door To Lt Panel With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Shall Have Louvers And Air Vent Gasket For Natural Flow Of Air Neoprene Adhesive Type Gasket Shall Be Used To Make Panel Vermin Proof And Comprising Of Following:- Please Enable Macros To View Boq Information 58 Supply, Install, Testing And Commissioning Of Lt Distribution Panel (Cpri Type Tested ) Cubicle Type Ip-65, Outdoor Type Confirming To Is-61439 Factory Fabricated Prewired Made Out Of 3.15 Mm Thick Crca Sheet Outer & 2 Mm Thick Crca Sheet Inner Of Suitable Size To Accommodate All Accessories/Fittings Compartmentalized In Construction To Accommodate The Incoming/Outgoing Mccb And Tpn Bus Bars And Outgoing Feeders. The Tpn Bus Bars Shall Be Insulted With Colour Coated Heat Shrinkable Sleeve And Shall Be Mounted On Dmc Support. The Incoming As Well As Outgoing Mccbs Shall Have Extension Links Of Current Carrying Cap Not Less Than 1.5 Times The Rated Capacity Of Individual Feeders. The Extension Links Shall Be Supported On Dmc Support Having Provision For Termination Of Incoming And Outgoing Cables. All Extension Links/ Interconnections Shall Be Colour Coated Sleeves. The Cubicle Shall Have Frame Work At Bottom Of Ms Channel Mc 100 Fixed To The Top Of Plateform. The Plateform Of Lt Panel Shall Be Pedestal Type Of Suitable Width And 600 Mm Height Above Ground Level And Minimum 400 Mm Below The Ground Level Constructed With Bricks (Sub ClassB) Work Duly Plastered In Cm 1:3 And Pcc Copping (1:2:4) Not Less Than 50 Mm Thick Over Brick Pedestal With Adequate Opening For Entry Of Cable Complete As Per Manufacture Recommendation And Directed By The Engr-In-Charge. A Detachable Gland Plate Of Thickness Not Less Than 3 Mm Thick Should Be Used At The Bottom For Entry Of Armoured Cable Of Adequate Size Compression Glands, The Panel Shall Be Painting With Powder Coated Finish With Ral 7032 Siemens Gray Structure After Seven Tank Phosphate Treatment Front & Back Opening Type And Fixing 2 Nos Danger Notice Plan With Letter Figures And Conventional Skull Bones In Signal Red Colour And Fixed Front & Back Door To Lt Panel With Voltage And Danger Indicated In Hindi And English With Double Door Shutter And Shall Have Louvers And Air Vent Gasket For Natural Flow Of Air Neoprene Adhesive Type Gasket Shall Be Used To Make Panel Vermin Proof And Comprising Of Following:- Please Enable Macros To View Boq Information
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
6.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
7.
Health and Family Welfare #11053902 Technical Bid
Tender For Drugs And Consumables , Drugs And Consumables , Oxygen (Medicinal Gas) Inhalation , Oxygen(Medicinal Gas) Inhalation Should Be Certified For Medical Use Contains Not Less Than 99% V/V Of Oxygen, Contains Not More Than 5Ppm V/V Of Carbanmonooxide, Contains Not More Then 30Ppm V/V Of Carban Dioxide Should Be Free Of Halogens, Oxidising Substances & Water. , Halothane Inhalation 250 Ml Bottle , Ketamine (As Hydrochloride) Injection 50 Mg /Ml,10 Ml Vial , Nitrous Oxide Inhalation , Thiopentone Injection Powder 0.5 G , Propofol Injection 1% Vial (10 Mg/Ml , 10 Ml Vial) , Isoflurane Inhalation 100 Ml Vial , Sevoflurane Inhalation 250 Ml , Bupivacaine Injection 0.5%, 5Ml Amp. , Bupivaccine Heavy 5 Mg With Dextrose Monohydrate 80 Mg/Ml Injection 4 Ml Ampoule , Lignocaine Injection 2%, 30 Ml Vial , Lignocaine Jelly 2% W/V ( With Seprate Nosal), 30Gm Tube , Lignocaine Hydrochloride And Adrenaline Bitartarate Injection 20Mg/Ml And 0.01Mg/Ml Adrenaline, 30 Ml Vial , Atropine Injection 0.6 Mg/Ml, 1 Ml Ampoule , Glycopyrolate Injection 0.2 Mg/Ml, 1 Ml Ampoule , Diazepam Injection 5 Mg/Ml, 2 Ml Ampoule , Diazepam Tablet 5 Mg , Midazolam Injection 1 Mg/Ml, 5 Ml Vial , Midazolam Nasal Spray 1.25 Mg/Spray , Diclofenac Supositories 50 Mg , Diclofenac Sodium Gastro-Resistant Tablet 50 Mg , Diclofenac (Sodium) Injection 25 Mg/Ml ,3Ml Amp. , Diclofenac Gel 1%, 30 Gm Tube , Diclofenac + Paracetamol Tablet 50Mg+325Mg , Ibuprofen Tablet 200Mg , Ibuprofen Tablet 400 Mg , Ibuprofen Suspension 100 Mg/5 Ml. 60 Ml Bottle , Paracetamol Tablet 500 Mg , Paracetamol Injection 150 Mg/Ml, 2 Ml Amp. , Paracetamol Peaditric 125Mg/5Ml 60 Ml Bottle , Paracetamol Paediatric Oral Suspension 150Mg/Ml, 10 Ml Vial With Marked Dropper , Paracetamol Infusion 100 Mg/10 Ml, 100 Ml Bottle Ffs Technology - , Aceclofenac Tablet 100 Mg , Etoricoxilb Tablet 90 Mg , Morphine Injection 10 Mg/Ml, 1 Ml Ampoule , Morphine Tablet 20 Mg , Tramadol Capsule 50 Mg , Tramadol Injection 50 Mg/Ml, 2 Ml Ampoule , Tramadol Hydrochloride Capsule 100 Mg , Pentazocine Injection 30 Mg/ Ml, 1 Ml Ampoule , Fentanyl Injection 50 Mcg/Ml, 2Ml Ampoule , Pethidine Injection 50 Mg/Ml, 1Ml Ampoule , Thiocolchicoside Capsule 4 Mg , Midazolam Nasal Spray 1.25 Mg/Spray , Beclofen Tablet 10 Mg Tablet , Allopurinol Tablet 100 Mg , Sulfasalazine Tablet 500 Mg , Methotrexate Tablet 2.5 Mg , Methotrexate Tablet 5 Mg , Naxproxen (500Mg)+ Domperidone (10Mg) Tablet , Diacerein 50 Mg + Glucosamine Sulphate 750 Mg Tablet - , Cetrizine Syrup 5 Mg/5Ml, 60 Ml , Chlorpheniramine Tablet 4 Mg , Pheniramine Maleate Injection 22.75 Mg/Ml, 2 Ml , Hydroxyzine Tablet 10 Mg , Dexamethasone Tablet 0.5 Mg , Dexamethasone Injection 4Mg/Ml, 2 Ml Ampoule , Hydrocortisone ( Sodium Sucinate Powder) Injection 100 Mg Vial, With 2 Ml Distilled Water For Reconstitution , Prednisolone Tablet 10 Mg , Prednisolone Tablet 20 Mg , Methyl Prednisolone Injection 1Gm, 1 Gm Vial With Diluent , Adrenaline Injection 1 Mg/Ml, 1:1000, 1 Ml Annual Periodical Maintenance , Levocetrizine Tablet 5 Mg , Nor Adernaline Injection 4Mg/Ml , Cyproheptadine Tablet 4 Mg , Monteleukast Tablet 5 Mg , Methyl Prednisolone Tablet 8 Mg , Antisnake Venom ( Dry Powder For Polyvalent Solution) Injection Vial With 10 Ml Diluent , Calcium Gluconate Injection 100 Mg/Ml, 10 Ml Annual Periodical Maintenance , Naloxone Injection 400 Mcg/Ml, 1Ml Ampoule , Pralidoxime (Pam) Injection 1 Gm Vial , Activated Charcoal Tablet 500 Mg , Carbamazepine Tablet 200 Mg , Carbamazepine Tablet 400 Mg , Carbamazepine Oral Solution 100Mg/5Ml, 30 Ml Bottle , Lorazepam Tablet 1 Mg , Lorazepam Tablet 2 Mg , Lorazepam Injection 4Mg, 2Ml , Magnesium Sulphate Injection 1 Gm /2Ml (50%W/V), 2 Ml Ampoule , Magnesium Sulphate Injection 2.5 Gm /5Ml(50%W/V), 5 Ml Ampoule , Phenobarbitone Tablet 30 Mg , Phenobarbitone Tablet 60 Mg , Phenobarbitone Injection 200 Mg/ Ml , Phenobarbitone Oral Solution 20 Mg/ 5 Ml,60 Ml Bottle , Phenytoin Tablet 100 Mg , Phenytoin Tablet 300 Mg , Phenytoin Oral Solution 25 Mg/Ml, 100 Ml Glass Bottle , Phenytoin (Sodium) Injection 100Mg, 2Ml Amp. , Sodium Valproate/Valproic Acid Enteric Coated Tablet 200 Mg , Sodium Valproate/Valproic Acid Enteric Coated Tablet 500 Mg , Sodium Valproate/Valproic Acid (Sodium)Controlled Released Tablet 300 Mg , Sodium Valproate Injection 100 Mg/Ml , Sodium Valproate Suspension 200 Mg/5 Ml, 100 Ml , Clobazam Capsule 10 Mg , Divalproex Sodium Tablet 500 Mg , Levetiracetam Tablet 500 Mg , Toperamate Tablet 50 Mg , Injection Levetricatum 100 Mg, 3 Ml - , Levitiracetam Oral Solution , Levitiracetam Oral Solution, 100Mg/Ml, 100Ml Bottle , Albendazole Chewable Tablet 400 Mg , Albendazole Oral Suspension 200 Mg/5 Ml,10 Ml Bottle , Levamasole Tablet 50 Mg , Levamasole Tablet 150 Mg , Amoxicillin Capsule 250 Mg , Amoxicillin Capsule 500 Mg , Amoxicillin Oral Suspension 125 Mg/5 Ml, 60 Ml Bottle , Amoxicillin + Pottasium Clavulanate Tablet 500 Mg + 125 Mg , Amoxicillin + Pottasium Clavulanate Dispersible Tablet 200 Mg +28.5 Mg , Amoxicillin + Clavulanic Acid Injection 1.2 Gm , 10 Ml Vial With Diluents , Amoxicillin + Clavulanic Acid Injection 250 Mg +50 Mg, Vial With Diluents , Ampicillin Sodium Injection 500Mg 2 Ml Vial With Diluent , Cefixime Tablet 200 Mg , Cefixime Oral Suspension 50 Mg/ 5 Ml, 30 Ml Bottle , Cefadroxil Oral Suspension 125 Mg/ 5Ml, 30 Ml Bottle , Cefotaxime Injection 250 Mg , Cefotaxime Injection 500 Mg 5 Ml Vial With Diluent , Cefotaxime Sodium Injection 1 Gm 10 Ml Vial With Diluent , Ceftriaxone Injection 250 Mg 2 Ml Vial With Diluent , Ceftriaxone Injection 1 G, 10 Ml Vial With Diluents , Benzathine Penicillin Injection Powder 12 Lacs Iu , Vial With Diluent , Cefoperazone + Sulbactam (1G+1G) Injection , Immipenum Injection 500 Mg , Imipenem And Cilastatin Injection (500 Mg+500 Mg) , Cefazolin Injection 1 Gm , Amikacin Injection 250Mg/ Ml, 2 Ml Vial , Amikacin Injection 50 Mg/ Ml, 2 Ml Vial , Gentamycin Injection 40 Mg/ Ml, 2 Ml Ampoule , Azithromycin Tablet 250 Mg , Azithromycin Tablet 500 Mg , Azithromycin Oral Suspension 40 Mg/Ml , 15 Ml Bottle , Levofloxacin Tablet 500 Mg , Ofloxacin Tablet 200 Mg , Ciprofloxacin Tablet 250 Mg , Ciprofloxacin Tablet 500 Mg , Ciprofloxacin Injection 2Mg/Ml, 100 Ml Bottle For Infusion Ffs Technology , Doxycycline Capsules 100 Mg , Cotrimoxazole (Sulfamethoxazole + Trimethoprim) Tablet 800 Mg + 160 Mg , Co-Trimoxazole [Sulphamethoxazole (A) + Trimethoprim (B)] Oral Liquid 200 Mg (A) + 40 Mg (B)/5 Ml , Metronidazole Tablet 200 Mg , Metronidazole Tablet 400 Mg , Metronidazole I.V Infusion 5 Mg/Ml, 100 Ml Bottle For Infusion (Ffs Technology) , Metronidazole Suspension 200Mg/5Ml , 60 Ml Bottle , Cloxacillin Capsule 500 Mg , Nitrofurantoin Capsule 100 Mg , Vancomycin Injection 500 Mg , Linezolid Tablet 600 Mg , Norfloxacin Tablet 400 Mg , Fluconazole Tablet 150Mg 10*10 , Fluconazole Tablet 200 Mg 10*10 , Griseofulvin Tablet 250 Mg , Itraconazole Capsules 200 Mg , Amphotericin B Powder For Injection 50 Mg And Vial Has Sodium Deoxychlolate Or Liposomal Complex , Terbinafine Tablet 250 Mg , Acyclovir Tablet 200 Mg , Acyclovir Tablet 400 Mg , Acyclovir Tablet 800 Mg , Tinidazole Tablet 500 Mg , Ivermectin Tablet 6 Mg , Diethyl Carbamazine Tablet 100Mg , Flunarazine Tablet 10 Mg , Propranolol Tablet (Sr) 40 Mg , Propranol Tablet 20 Mg , Levodopa + Carbidopa Tablet 100 Mg + 10 Mg , Trihexyphenidyl Tablet 2 Mg , Bromocriptine Tablet 2.5 Mg , Ferrous Sulpahte + Folic Acid Syrup 100 Mg + 0.5 Mg/ 5 Ml In A Flavoured Base/Vehicle 50 Ml Bottle, Ropp Cap Bottle With Inert Liner & Bottle To Be Provided With A Dispenser To Dispense To 1 Ml, 1.5Ml And 2 Ml Each Time And Packed In A Mono Carton Note:- For Detailed Specifications Kindly See Below Attached Copy. , Elemental Iron 60 Mg +Folic Acid 500 Mcg, Sugar Coated And Red Color Tablet , Ferrous (Iron Sucrose) Injection 20 Mg/Ml , Folic Acid Tablet 5Mg , Hydroxycobalamin Injection 1 Mg/ Ml , Warfarin (Sodium) Tablet 2 Mg , Heparin Injection 1% , Enoxaprin Sodium Injection 60 Mg In Pfs , Phytomenadion Injection 1 Mg/0.5 Ml Water Based Single Dose Ampoule , Plasma Volume Expander Injection ( Each 100 Ml Contains Polygeline, Polypeptides Of Degaraded Gelatin, Cross Linked Via Urea Bridges 3.5 G ( Equivalent To 0.63 G Of Nitrogen) Nacl Ip 0.85 G, Kcl Ip 0.038 G Cacl2 Ip 0.070G Water For Injection Ip Q.S Electrolytes In M.Mol/Litre, 500 Ml Ffs , Glyceryl Trinitrate (Sublingual) Tablet 500 Micrograms , Glyceryl Trinitrate ( Niroglycerine) Injection 5 Mg/Ml, 5 Ml Ampule , Isosorbide Mononitrate Tablet 30 Mg (Sr) , Isosorbide Dinitrate Tablet (Sublingual) 5 Mg , Metoprolol Tablet 25 Mg , Metoprolol Tablet (Sr) 50 Mg , Carvediolol Tablet 3.125 Mg , Adenosine Injection 3 Mg/ Ml, 1 Ml Ampoule , Diltiazem Injection 5 Mg/Ml , Diltizem Hydrochloride Tablet 30 Mg (Modified Release), 10*10 , Amiodarone Tablet 100 Mg , Verapamil Tablet 40 Mg , Amiodarone Injection 150 Mg/ 3 Ml , Atenolol Tablet 50 Mg , Amlodipine Tablet 5 Mg , Amlodipine Tablet 10 Mg , Methyldopa Tablet 250 Mg , Methyldopa Tablet 500 Mg , Nifedipine Capsule(Sublingual) 5 Mg , Nifedipine Tablet Ip Sr/Er 10 Mg , Ramipril Tablet 5 Mg , Labetalol Tablet 100 Mg , Labetolol Injection 5Mg/Ml, 4Ml Amp. , Telmisartan Tablet 40 Mg , Telmisartan Tablet 80 Mg , Losartan + Hydrochlorothiazide Tablet (50 Mg + 12.5 Mg) , Olmesartan 20 Mg + Amlodipine 5 Mg + Hydrochlorothiazide 12.5 Tablet , Clinidipine Tablet 20 Mg , Hydrochlorthiazide Tablet 12.5 Mg , Chlorthalidone Tablet 6.25 Mg , Nebivalol Tablet 5 Mg , Enalapril Tablet 5 Mg , Dobutamine Injection 250Mg/5Ml , Dopamine Injection 40 Mg/ Ml In 5Ml Ampoule , Digoxin Tablet 0.25 Mg , Acetylsalicylic Acid Tablet 150 Mg , Acetylsalicylic Acid Tablet 75 Mg Gastro-Resistant (Enteric Coated/ Delayed Release) , Clopidogrel Tablet 75 Mg , Streptokinase Injection Powder 1500000 Iu , Atorvastatin Tablet 10 Mg , Atorvastatin Tablet 20 Mg , Rosuvastatin 10 Mg+ Fenofibrates 160 Mg Tablet , Tranexamic Acid Tablet 500 Mg , Tranexamic Acid Injection In Water For Injection 100 Mg/Ml, 5 Ml Ampoule , Mephentermine Injection 30 Mg/Ml, 1 Ml Amp. , Tranexamic Acid 500 Mg + Mefenamic Acid 250 Mg Tablet , Citicoline Tablet 500 Mg , Clotrimazole Pessaries 200 Mg , Clotrimazole Cream 2% W/W, 15 Gm , Clotrimazole Mouth Paint 1% W/V In Propylene Glycone Glycerian Base 15 Ml , Sertaconazole Cream 2% W/W, 15 Gm , Ketaconazole Lotion 2% W/V, 50 Ml , Acyclovir Eye Ointment 3% , 4.5 Gm Tube , Clindamycin Gel 1% W/W, 10Gm Tube , Clobetasol 0.05% + Gentamycin 0.1% Ointment 15 Gm Tube , Silver Sulfadiazine Cream 1%, 30 Gm Tube , Framycetin Cream 1%, 30 Gm Tube , Gentian Violet (Methylrosanilinium Chloride Paint Preparation Aqueous Solution 0.5%W/V), 50 Ml Dark Bottle , Benzoyl Per Oxide Gel 2.5%, 20 Gm Tube , Permethrin Lotion 5%, 50 Ml , Permethrin Cream 5%, 30 Gm , Betamethasone Dipropionate Cream 0.1% W/W , 5 Gm , Fluticasone Cream 0.01 % 10Gm , Calamine Lotion Ip-Calamine Ip-15% W/V, Zinc Oxide Ip-5%W/V,Glycerin Ip-5% W/V ,65Ml Bottle , Benzyl Benzoate 25% Lotion 100 Ml , Podophylline Resin Topical Solution 25% , 10 Ml Bottle , Fusidic Acid Cream 2%, 10Gm Tube , Coal Tar Solution 5% W/V, 100 Ml Bottle , Salicylic Acid Ointment 6%, 15 Gm Tube , White Petrolatum Jelly 100 %, 50 Gm Jar , Clotriamazole 1%+ Beclomethasone Dipropionate 0.025% Lotion 15 Ml , Mometasone Furoate Cream 0.1 % W/W , Mometasone Furoate Cream 0.1 % W/W, 10Gm Tube , Hydroquinone 2.0% W/W + Tretinoin 0.025% W/W + Mometasone Furoate 0.1% W/W In A Cream Base Q.S , Kojic Acid Cream 2 % , Hydroquinone 2%/4% + Tretinoin 0.025 % +Fluocinolone Skin Cream , Hydroquinone 4%+ Tretinoin 0.05% +Fluocinolone 0.01 % Skin Cream, 15Gm , Tacrolimus Ointment 0.03% W/W, 10 Gm , Tacrolimus Ointment 0.1% 10Gm Tube , Choline Salicylate Solution Bp Equivalent To Choline Salicylate 8.7 % W/W, Benzalkonium Chloride Solution Ip 0.01 % W/W, Lignocaine Hydrochloride Ip 2.0 % W/W Gel Base Q.S., 10 Ml Packing , Sunscreen Lotion Spf 26 ,100Ml Bottle , Clobetasone Butyrate(0.05 W/W + Miconazole(2.0 W/W) ,15 Gm Cream - , Halobetasol Propionate(0.5% W/W + Salicylic Acid (3% W/W) , 10Gm Ointment , Minoxidil Solution 5%, 60Ml Bottle , Gamma Benzene Hexachloride 1% Lotion,100 Ml , Sertaconazole Nitrate 2 % W/W+ Beclomethasone Dipropionate 0.025% W/W, 15Gm Tube , Cotrimazole 1%+ Beclomethasone Dipropionate 0.0025% Lotion 15 Ml Lotion 1%, 0.0025%, 15Ml , Mupirocin Cream 2% W/W,5Gm Tube , Isotretinoin Capsule 20 Mg , Methoxsalen Tablet 10 Mg , Triamcinolone Injection 20 Mg/ Ml , Triamcinolone Injection 40 Mg/Ml , Povidone Iodine Solution 5% ,500 Ml , Povidone Iodine Ointment 5%,15 Gm , Povidone Iodine Scrub (Povidone Iodine Cleansing Solution 7.5 %, W/V With Foaming Agent) 500 Ml , Povidine Iodine Scrub 7.5% W/V, 500Ml , Hydrogen Peroxide Solution 6%, 400 Ml Bottle , Cetrimide Solution 20% Concrete For Dilution, 500 Ml Plastic Bottle , Chlorhexidine Solution 5% Concrete For Dilution, 500 Ml , Bleaching Powder Containg Not Less Then 30% W/W Of Avialble Chlorine, 1Kg/25 Kg , Feracrylum 1% W/W Sterile Solution 100Ml Bottle , Feracrylum 3% W/W Gel , 15Gm Tube , Tritium Vulgare Extract And Phenoxyethanol Cream,32Gm Tube , Glutraldehyde Solution 2% - 2.5%, 1 Litre Pack , Potassium Permanganate Crystal For Solution 100 Gm , Bleaching Powder Containg Not Less Then 30% W/W Of Available Chlorine Powder - , Furosemide Tablet 40 Mg , Furosemide Injection 10 Mg/Ml, 2Ml Ampoule , Mannitol Intravenous Infusion 20% W/V, 100Ml Ffs Technology , Spironolactone Tablet 25 Mg , Torasemide Tablet 10 Mg , Tamsulosin 0.4 Mg + Dutasteride 0.5 Mg Tablet , Disodium Hydrogen Citrate Oral Solution/Syrup 1.38 -1.45 Gm/ 5 Ml, 100 Ml Bottle , Sodium Bicarbonate Infusion 7.5% W/V, 10 Ml Ampoule , Alkalizer Mb6 500Ml (Potassium Citrate Magnisum Citrate Syrup & Vit B6) , Bethanecholchloride Tablet 25 Mg , Darifenacin Tablet 7.5 Mg , Silodosin Tablet/Capsule 8.0 Mg , Mirabegron Tablet 50 Mg , Pyridium Tablet 200 Mg , Aluminium Hydroxide 240 Mg + Magnesium Hydroxide 100Mg+ Simethicone 25 Mg + Magnesium Carbonate 60 Mg Chewable Tablet , Dried Aluminium Hydroxide Gel + Magnesium Hydroxide + Simethicone Oral Suspension 250 Mg+ 250 Mg+ 50 Mg/ 5 Ml, 170 Ml Bottle , Ranitidine Injection 25 Mg/Ml, 2 Ml Annual Periodical Maintenance , Ranitidine Syrup 150 Mg/10 Ml , Ranitidine Tablet 150 Mg, Film Coated , Omeprazole Capsule 20 Mg , Pantoprazole Injection 40 Mg, Vial With 10 Ml Diluent , Pantoprazole + Domperidone Special Repair (40Mg+30Mg) Capsule , Sucralfate 1Gm With Oxetacain 10Mg/10Ml Suspension , Simethicone Syrup 40Mg,60 Ml Bottle , Domperidone Tablet 10 Mg , Domperidone Suspension 1 Mg/Ml, 30 Ml Bottle , Cinnarizine Tablet 25 Mg , Metoclopramide Tablet 10 Mg , Metoclopramide Injection 5 Mg/Ml, 2 Ml Ampoule , Ondansetron Tablet 8 Mg , Ondansetron Injection 2Mg/Ml ,2Ml Ampoule , Ondansetron Oral Liquid 2 Mg/ 5 Ml , Ondansetron Oral Liquid 2Mg/5 Ml , 30 Ml Bottle , Promethazine Injection 25 Mg/Ml, 2 Ml Annual Periodical Maintenance , Promethazine (Hydrochloride) Elixir Or Syrup 5 Mg/5 Ml, 60 Ml Bottle , Doxylamine Tablet 10 Mg , Prochlorperazine Mouth Dissolving Tablet Flavored Base 5Mg , Anti-Haemorrhoidal Containing: Beclomethasone Dipropionate 0.025% W/W, Phenylephrine Hyderochloride 0.10% W/W, Lignocaine Hydrochloride 2.5% W/W In Soft Paraffin Base 20 Gm Tube , Dicyclomine Tablet 10 Mg , Dicyclomine Oral Solution 10Mg/5Ml , Mephenamic Acid + Dicyclomine Tablet 500 Mg +20 Mg , Drotaverine Tablet 80 Mg , Drotaverine Injection 40 Mg/ 2 Ml , Hyoscine Butyl Bromide Tablet 10 Mg , Hyoscine Butyl Bromide Injection 20 Mg/ Ml, 1 Ml Amp. , Bisacodyl Gastro-Resistant (Enteric Coated/Delayed Release) Tablet 5 Mg , Lactulose Solution 10 Gm/ 15 Ml, 60 Ml Bottle , Ispaghula Granules/ Husk/ Powder 100 Gm , Enema , Dioctyl Sulfosuccinate Sodium Liquid,100 Ml , Magnesium Hydroxide Liquid 100 Ml , Oral Rehydration Salts Powder For 1000 Ml Solution , Oral Rehydration Salts Powder For 200 Ml Solution , Zinc (Sulphate) Dispersible Tablet 20 Mg , Octreotide Injection 100 Mcg/Ml, Single Dose 1 Ml Vial , Levosulpride (Sr) 75 Mg + Rabeprazole (Ec) 20 Mg Capsule , Saccharomyces Boulardii 5 Cfu Sachets , Probiotic Capsule/Syurp (Vizylac/Sporolac) , Probiotic Syrup (Streptococus Faecalis 30 Million, Clostridium Butirium 2 Million,Bacillius Mesentiricus 1 Million,Lactic Acid Bacillus 50 Million) Suspension In 5Ml , Probiotic Capsule (Lactobacillius Blends) , Chymotrypsin+ Trypsin (1:6 ) Tablet 100K Au , Cyproheptadine Hcl Ip-2Mg, Tricholine Citrate-275 Mg, Sorbitol Solution (70%)(Non Crystallising) Ip-2 Gm, 200 Ml Bottle , Erythropoietin Injection 4000 Units/Ml, Single Dose 1 Ml Vial , Insulin (Soluble) Injection 40 Iu/Ml In 10 Ml Vial , Intermediate-Acting Insulin (Nph) Injection 40 Iu/Ml In 10 Ml Vial , Biphasic Isophane Injection 40 I.U/Ml, (30/70), 10 Ml Vial , Lantus Insulin (Insulin Glargine 100 Units/Ml) , Metformin Tablet 500 Mg , Metformin Tablet 1 Gm , Metformin Tablet Special Repair 500Mg , Metformin Tablet Special Repair 1 Gm , Glimipride Tablet 1 Mg , Glimipride Tablet 2 Mg , Teneligliptin Film Coated Tablet 20 Mg , Voglibose 0.3 Mg + Metformin 500Mg+ Glimipride 1 Mg Tablet , Vildagliptin Tablet 50 Mg , Empagliflozin Tablet 10 Mg , Glibenclamide Tablet 5 Mg , Clomifene Citrate Tablet 50 Mg , Medroxyprogesterone Tablet 10 Mg , Norethisterone Tablet 5 Mg , Micronized Progesterone Tablet 200 Mg , Mifepristone Tablet 200 Mg , Mifepristone Tablet 25 Mg , Cabergoline Tablet 0.5 Mg , Dienogest Tablet 2 Mg , α -Hydroxyprogesterone Injection 500 Mg , Hcg 5000 Iu(Human Chorionic Gonadotropin) Injection , Conjugated Estrogen Tablet 0.625 Mg , Ethamsylate Tablet 500 Mg Tablet - , Latrazole Tablet 2.5 Mg , Thyroxine Tablet 50 Mcg , Carbimazole Tablet 5 Mg , Ethinyestradiol Tablet 5 Mcg , Estrogens Cream 0.625 Mg , Ethinylestradiol Tablet (0.03 Mg+ Levonorgestrel (0.15) Tablet 0.03Mg, 0.15 , Copper Bearing Intra-Uterine Device Iucd 380 A & Iucd 375 - , Male Condom - , Non Harmonal Ormeloxifene 30Mg Tablet , Emergency Contraceptive Pill Levonorgestrel Tablet 1.5 Mg , Pregency Testing Kit - , Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 150 Mcg/Vial , Anti-Rho-D Immunoglobulin(Human) Injection (Polyclonal) Injection 300Mcg/Vial , Injection Recombinant Anti-D Immunoglobulin 300Mcg Vial/Pfs , Anti Rabies Immunoglobulin Injection (Human) 150 Iu/Ml, 2Ml Vial , Hepatitis B Immunoglobulin Injection 1Ml. , Hepatitis B Immunoglobulin Injection 100 Iu, 1 Ml Vial - , Tetanus Toxoid Injection 0.5 Ml Ampoule , Rabies Vaccine Single Dose Rabies Vaccine 2.5 Iu Injection For Human Use Prepared In Chick Embryo/ Vero Cell/ Human Diploid Culture Single Dose With Diluent And Disposable Syringe With Needle , Decaravimab+ Miromavimab Injection (600 Iu) 3 Ml , Atracurium Besylate Injection 10 Mg/ Ml, 2.5 Ml Amp. , Succinyl Choline Injection 50Mg/Ml, 10Ml Vial , Neostigmine Injection 500 Mcg/ Ml, 5 Ml Ampoule , Vecuronium Injection 10 Mg Vial , Ciprofloxacin Eye Drops 0.3%, 10 Ml Plastic Bottle , Ciprofloxacin Opthalmic Ointment 0.3 % 5 Gm Tube , Tobramycin Opthalmic Solution 0.3% W/V, 5Ml , Natamycin Eye Drops 2%, 5 Ml , Acylovir Eye Oint 5%,5 Gm , Povidone Iodine 5% Eye Drops , Prednisolone Sodium Phosphate Eye Drops 1%, 5 Ml , Flurbiprofen Eye Drops 0.03%, 10 Ml Vial , Flouromethalone Eye Drops 0.1 % W/V,5 Ml Vial , Olopatadine 0.1% Eye Drops 5 Ml , Acetazolamide Tablet 250 Mg , Timolol Eye Drops 0.5%, 5Ml , Atropine Drops 1% , Homatropine Eye Drops 1% , Tropicamide + Phenylepherine Eye Drops 0.8% + 5%, 5 Ml Vial , Cyclopentolate Eye Drops 1% W/V , Sodium Carboxymethyl Cellulose Eye Drops 0.5% W/V, 10 Ml , Hydroxypropyl Methylcellulose Injection 2% , 3 Ml Pfs (Glass Syringe) , Hyaluronidase Injection 1500 Iu/Ml , Tryptan Blue Dye 0.06% W/V, 1 Ml Vial , Moxifloxacin Eye Drops 0.5% W/V ,5Ml , Ranibizumab Injection 10Mg/Ml , Travoprost 40 Mg/Ml 2.5Ml Vial Eye Drop , Xylometazoline Nasal Drops 0.05 %, 10 Ml , Xylometazoline Nasal Drops 0.1 %, 10 Ml , Saline Nasal Drops 0.65%, 10 Ml , Wax Dissolving Ear Drops (Paradichlorbenzene 2% W/V, Benzocain 2.7 % W/V, Chlorbutol 5% W/V, Turpentine Oil 15% Ear Drops ), 10 Ml , Clotrimazole 1% W/V + Lignocaine Hydrochloride 2% W/V Ear Drops, 5Ml Bottle , Clotrimazole Ear Drops 5 Ml Vial , Ichthoimol Glycerine Solution 10 Ml Vial , Ciprofloxacin(0.3%)+Dexametasone(0.1%) Ear Drops ,5Ml , Antibacterial & Anti Fungal Ear Drop (Beclomethasone 0.025% W/V +Chloramphenicol 5% W/V +Clotrimazole 1% W/V ,Glycerine Base), 10 Ml Ear Drops , Fluticasone Furoate Nasal Spray , Fluticasone Furoate Nasal Spray 27.5Mcg, 10Ml , Boro-Spirit Ear Drops,3% W/V Ear Drops 10 Ml , Methyl Ergometrine Tablet 125 Mcg , Methyl Ergometrine Injection 200 Mcg In 1 Ml Ampoule , Oxytocin Injection 5 Iu In 1 Ml Ampoule , Carboprost Injection 250 Mcg In 1 Ml Amp./ Vial , Misoprostol Tablet 200 Mcg , Misoprostol Tablet 25 Mg , Dinoprostone Gel 0.5 Mg, 3 Gm , Isoxsuprine Tablet 10 Mg , Isoxsuprine Injection 5 Mg/ Ml,2Ml Ampoule , Valethamate Injection 8 Mg/Ml , Betamethasone Injection 4Mg/Ml , Chlorpromazine (Hydrochloride) Tablet 100 Mg , Fluphenazine Injection 25 Mg, 1 Ml Ampoule , Haloperidol Tablet 5 Mg , Haloperidol Injection 5Mg/1 Ml, 1 Ml Annual Periodical Maintenance , Haloperidol Injection Long Acting 50 Mg , Risperidone Tablet 2 Mg , Risperidone Tablet 4 Mg , Risperidone Injection Long Acting 25 Mg , Quetiapine Tablet 50 Mg , Quetiapine Tablet Special Repair 100 Mg , Aripipralzole Tablet 10 Mg , Aripiprazole Tablet 15 Mg , Aripiprazole Tablet 5 Mg , Olanzapine Tablet 20 Mg , Olanzapine Tablet 10 Mg , Olanzapine Injection 405 Mg , Olanzapine Injection 10 Mg , Olanzapine Injection 210 Mg Long Acting , Olanzapine Injection 300 Mg Long Acting , Clozapine Tablet 100 Mg , Clozapine Tablet 50 Mg , Amitriptyline Tablet 10 Mg , Amitriptyline Tablet 25 Mg , Fluoxetine Capsule 20 Mg , Imipramine Tablet 25 Mg , Sertraline Tablet (Sr) 50 Mg , Sertraline Tablet 100 Mg , Escitalopram Tablet 10 Mg , Paroxetine (Cr) Tablet 25 Mg , Paroxetine Tablet (Cr) 12.5 Mg , Capsule Venalafaxine Extended Release 37.5 Mg , Capsule Venalafaxine Extended Release 75 Mg , Gabapentin + Nortriptyline (400/10Mg) Tablet , Mirtazapine Tablet 15 Mg , Dothiepin Tablet 25 Mg , Lithium Carbonate Tablet 300 Mg , Lithium Tablet 400 Mg Special Repair , Alprazolam Tablet 0.25 Mg , Alprazolam Tablet 0.5 Mg , Donepezil Tablet 5 Mg , Donepezil Tablet 10 Mg , Clonazepam Tablet 0.5 Mg , Clonazepam Tablet 1 Mg , Donepezil Injection 10 Mg , Etizolam Tablet 0.50 Mg , Duloxetine Tablet 30 Mg , Bupropion Tablet 150 Mg , Buprinorphine Tablet 2 Mg , Buprinorphine Tablet 0.4 Mg , Disulfiram Tablet 250 Mg , Disulfiram Tablet 500 Mg , Nicotin Chewgum 2 Mg , Nicotin Chewgum 4 Mg , Naltrexone Tablet 50 Mg , Amisulpride Tablet 50 Mg , Pregablin 75Mg +Methylcobalmin 1500Mg +Nortriptylline 10Mg , Methylphenidate Tablet 5 Mg , Memantine Tablet 5 Mg , Tranylcypromine Tablet 5 Mg , Desvenlafaxine Tablet 50 Mg , Buprenorphine Transdermal Patch 10 Mcg/Hour , Buprenorphine Transdermal Patch 20 Mcg/Hour , Lacosamide Tablet 100 Mg , Blonanserin Tablet 4 Mg , Breviteracetam Tablet 50 Mg , Eeg Paste , Agomelatine Tablet 25 Mg , Vortioxetine Tablet 10 Mg , Melatonin Tablet 3 Mg , Tadalafil 10 Mg , Perampenel 2 Mg , Fluvoxamine 150 Mg , Ursodeoxycholic Acid Tablet 300 Mg , Cariprazine Tablet 1.5 Mg , Atomoxitine Capsule 10 Mg , Betahistine Tablet 8 Mg , Lamotrigine Tablet 25 Mg , Salbutamol Tablet 4 Mg , Salbutamol Syrup 2 Mg/5 Ml, 100 Ml Bottle , Salbutamol Inhaler Areosol 100 Microgram/ Dose, Mdi, Single Packing , Salbutamol Nebulizer /Respirator Sol. 2.5Mg, 2.5Ml Respule , Etophylline + Theophylline Tablet 231 Mg + 69 Mg (Sr) , Etophylline + Theophylline Injection 169.4 Mg + 50.6 Mg/2 Ml Ampoule , Budesonide Inhalation 200 Mcg/Dose, 200 Mdi/Dpi , Budesonide Nasal Spray 100 Mcg/Dose, Single Unit , Budesonide Respirator Solution For Use In Nebulizer 1 Mg, 2Ml Respule , Ipratropium Respirator Solution For Use In Nebulizer 250Mcg/ 1Ml, 2 Ml Respule , Cough Expectorent (Salbutamol+Bromhexine ) Syrup 2 Mg +4 Mg , Aminophylline Injection 25 Mg/ Ml, 10 Ml Ampoule , Budesonide + Formoterol Inhalation (200 Mcg + 6 Mcg), 120 Mdi , Cough Syrup Diphehydramine 14.08 Mg + Ammonium Chloride 138 Mg + Sodium Citrate 57.03Mg + Menthol Ip 1.14 Mg/5 Ml, 100 Ml Bottle 110 Ml Bottle , Cough Syrup Diphehydramine 14.08 Mg + Ammonium Chloride 138 Mg + Sodium Citrate 57.03Mg + Menthol Ip 1.14 Mg/5 Ml, 100 Ml Bottle - , Cough Syrup Ambroxol 15 Mg+ Terbutaline Sulphate 1.25 Mg+ Guaiphenesin 50 Mg+ Menthol 2.5 Mg, 100 Ml Bottle , Doxofylline Tablet 400 Mg , Dextromethorphan (15Mg/5Ml)+Chlorpheniramine Maleate (2Mg/5Ml) +Phenylephrine Hcl (5Mg/Ml) Oral Syrup, 100 Ml Bottle , Caffeine Citrate Injection 20 Mg/Ml (Equivalent To 10 Mg Caffeine Base/Ml) , Caffeine Citrate Oral Solution 20 Mg/Ml,3Ml , Clarithromycin Tablet 500 Mg , N- Acetylcysteine Tablet 600 Mg , Glycopyrronium 25 Mcg + Formoterol Fumarate 12 Mcg Rota Caps , Oral Glucose 75 Gm , Dextrose Intravenous Infusion Ip 5 % W/V , 500 Ml Ffs Bottle , Dextrose Intravenus Infusion Ip 10% W/V, 500 Ml Ffs Bottle , Dextrose Intravenous Infusion Ip 25% W/V, 100 Ml Ffs Bottle , Dextrose 5 % W/V With Sodium Chloride 0.9% W/V For Intravenous Infusion 500 Ml Ffs Bottle , Multi Electrolyte Injection (Isolyte P Multiple Electrolyte & Dextrose Injection Type 1 ), 500 Ml Ffs Bottle , Potassium Chloride Oral Solution 10%, 100 Ml Bottle , Potassium Chloride (Solution) Injectable 15% (150Mg/Ml) , 10 Ml Amp. , Ringer Lactate (Solution ) For Injection ( Compound Sodium Lactate) 500 Ml Ffs Bottle , Normal Saline (Sodium Chloride) Injection Solution 0.9% Isotonic, 100Ml , Normal Saline Injection 3% , Normal Saline (Sodium Chloride) Injection 0.9% W/V, 500 Ml Bottle ( Ffs Technology) , Water For Injection 5Ml Ampoule , Injection Human Albumin 5% Infusion Solution 5% , Injection Human Albumin 20% Infusion Solution 20 , Ascorbic Acid Tablet 500 Mg , Pyridoxine Tablet 10 Mg , Pyridoxine Tablet 100 Mg , Vitamin A Oral Solution 100000 Iu/Ml, 100 Ml , B-Complex Tablet , Vitamin D3 Drops 400 Iu/Ml , Vitamin D3 Tablet (Chewable) 60000Iu , Calcium Salts 500 Mg+ Vitamin D3 250 Iu Tablet , Thiamine Injection 100 Mg/Ml, 2 Ml Vial , Calcium Phosphate Suspension/Syrup:- Each 5Ml Contains: Vit D3 (Cholecatciferol) Ip-200Iu Vitamin B12 (Cyanocobalamin) Ip 2.5Mcg, Calcium- 82Mg (As A Mixture Of Calcium Phosphats Calculated As 0.12G Ca3 (Po4) 2 Suspension/Flavoured Syrupy Base- Q.S. 200Ml Bottle. , Hematinic With Amino Acids Vitamin And Zinc Syrup 200 Ml Bottle, Each 10 Ml Contains: Ferrous Glycine Sulphate-216.50Mg, L-Histidine Hcl-25.0 Mg, Pyridoxine Hydrochloride Ip-1.5 Mg, Nicotinamide Ip-25.0 Mg, Folic Acid Ip-0.5 Mg, Cyanocobalamin Ip-2.5 Mcg, Zinc Ascorbate 50 Mg, Approved Colors Used , Multi Vitamin Infusion 10 Ml: Each Ml Contains Vitamin A (As Vitamin A Concentrate Oily Form) Lp 1100 Lu, Cholecalciferol Lp 100 Lu, Tocopheryl Acetate Lp 0.5Mg, Nicotinamide Lp 10Mg, Riboflavin Sodium Phosphate Lp 1.4Mg, Pyridoxine Hydrochloride Lp 1.65Mg, Thiamine Hydrochloride Lp 5.0Mg, Ascorbic Acid Ip 50.0Mg, L-Cysteine Hydrochloride Usp 0.2Mg, Benzyl Alcohol (As Preservative) Lp 1.0% V/V, Water For Injections Lp Q.S , Methylcobalamin Tablet 1500 Mcg , Pregabalin 75 Mg+ Methylcobalamin 1500 Mcg Tablet , Alfacalcidol Soft Gelatin Capsule 0.25 Mcg , Biotin Tablet 10 Mg , Thiamine Tablet 100 Mg , 10 Essential Amino Acid With Vitamins And Minerals Capsules (10X10) , Amino Acid Iv Infusion Minimum 10 Essential Amino Acids, 250Ml Bottle - , Artesunate Injection 60 Mg/Ml , Chloroquine Phosphate Injection 40 Mg/Ml , Chloroquine Phosphate Tablet 250 Mg, Equivalent To 155 Mg Chloroquine Base , Chloroquine Phosphate Oral Solution 50 Mg/ 5 Ml, 50 Ml Bottle , Primaquine Tablet 2.5 Mg , Primaquine Tablet 7.5 Mg , Primaquine Tablet 15 Mg , Quinine Sulphate Tablet 300 Mg , Quinine Dihydrochloride Injection 300 Mg/Ml, 2 Ml Ampoule , Sulfadoxine + Pyrimethamine Tablet 500 Mg + 25 Mg , Temphos 50% Ec 5 Liter Pack , Malathion Technical 95%, 250 Kg , Deltamethrin 2.5% Wp, 25 Kg , Cyphenothrin 5% Ecs (Insecticide/Adulticide For Fogging) , Bivalent Antigen Based Rapid Diagnostic Kit For Malaria , Pyrethrum Extract 2% , Dengue Ns1 Antigen Elisa Based Test Kit,96 Test/Kit - , Mac Elisa Igm Dengue Kit , Sofosbuvir 400 Mg Tablet + Ledipasvir 90 Mg Tablet , Sofosbuvir 400 Mg Tablet , Daclatasvir 60 Mg Tablet , Daclatasvir 30 Mg Tablet , Entecavir 1 Mg Tablet , Entecavir 0 .5 Mg Tablet , Ribavirin Capsules 200 Mg , Tenofovir Tablet 300 Mg , Sofosbuvir 400Mg+ Velpatasvir 100 Mg Tablet , Rtpcr Kits For Quantitative Viral Load Test For Hepatitis B Virus , Rtpcr Kits For Quantitative Viral Load Test For Hepatitis C Virus , Storage Vial 5 Ml , Racked Filter Pipette Micro-Tips(Sterile) 10 Ul , Racked Filter Pipette Micro-Tips(Sterile) 20 Ul , Racked Filter Pipette Micro-Tips(Sterile) 1000 Ul , Racked Filter Pipette Micro-Tips(Sterile) 200 Ul , Filter Pipette Micro-Tips (Sterile) 10 Ul , Filter Pipette Micro-Tips (Sterile) 20 Ul , Filter Pipette Tips (Sterile) 100 Ul , Filter Pipette Tips (Sterile) 200 Ul , Filter Pipette Tips (Sterile) 1000 Ul , Ethanol Imported (20 Bottles Per Bottle) 5 Liter Pack , Molecular Biology Grade Water As Per Requirement , Screw Capped Storage Vial 2Ml (500 Vials) Per Pack 2 Ml , 100 Well Micro Tube Storage Box , Para Film , Blue Nitrile Gloves , Single Channel Variable Volume Micropipette 0.5-10 Ul , Single Channel Variable Volume Micropipette 02-20 Ul , Single Channel Variable Volume Micropipette 05-50 Ul , Single Channel Variable Volume Micropipette 10-100 Ul , Single Channel Variable Volume Micropipette 20-200 Ul , Single Channel Variable Volume Micropipette 100-1000 Ul , 96 Well Qper Plates With Adhesive Optical Scaling Membrane , Individual Pcr Tubes 8-Tube Strips(Clear) , Optical Flat 8-Cap Strips 0.2Ml Tube Strips , 8 Channel Variable Value Micropipette 2-20 Ul , Micro Centrifuge Tubes Mctival (Sterile) 2 Ml , 96 Well Reversible Rack F 0.5 To 2.0Ml Vials , Rnase And Dnase Degradation Solution , Rnase And Dnase Degradation Solution Wipes , Dna Blood Extraction Kit , Viral Rna Extraction Kit , Purified Freeze € Dried Human Coagulation Factor Viii, Virus Inactivated Injection 250 Iu , Anti Hemophillic Factor Ix Vial Injection Size 500 Iu , Anti Hemophillic Factor Vii Injection 1Mg,Vial/Ampoule , Anti Hemophillic Factor Vii Injection 2Mg,Vial/Ampole , Anti Hemophillic Factor Viii Inhibitor Bypassing Agent Injection 500 Iu,Vial/Ampoule , Anti Hemophillic Factor Viii Inhibitor Bypassing Agent Injection 1000 Iu,Vial/Ampoule , Recombinant Anti Haemophilic Factor Viii (Rf Viii)Standard Half Life Injection 250 Iu , Recombinant Anti Haemophilic Factor Viii (Rf Viii)Extended Half Life Injection 500 Iu , Recombinant Anti Haemophilic Factor Ix(Rf Ix )Standard Half Life Injection 250 Iu , Recombinant Anti Haemophilic Factor Ix (Rf Ix)Extended Half Life 500 Iu , Emicizumab-Kxwh Injection 30 Mg/Ml , Emicizumab-Kxwh Injection 60 Mg/0.4 Ml , Anti Haemophilic Factor Ix Vial Injection 600Iu , Leuco Reduction Filter Bed Side For Packed Red Blood Cells - , Sanitary Napkin , Weekly Iron Folic Acid Tablet Each Tablet Containing 60 Mg Elemental Iron+500 Mcg Folic Acid, Sugar Coated ,Blue Colour , Iron And Folic Acid Tablet ( Wifs Junior ) Containing Dried Ferrous Sulphate Ip Equivalent To Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet. Tablet Are Sugar Coated And Pink Coloured Tablets With Only Edible Colours Used Tablet Ferrous Iron 45Mgm And Folic Acid Ip 0.4Mg Per Tablet , Salt Testing Kit , Oseltamivir Tablet 75 Mg , Oseltamivir Tablet 45 Mg , Oseltamivir Tablet 30 Mg , Oseltamivir Syrup (Each 1 Ml Reconstituted Suspension Contain 12 Mg Oseltamivir, 75 Ml Bottle) Syrup , Seasonal Influenza Quadrivalent/ Tetravalent Vaccine , Deferiprone Tablet 500 Mg , Deferasirox Tablet 500 Mg , Desferrioxamine Injection 500 Mg , Medroxyprogesterone Acetate Injection Ip (Dmpa ) 25 X 1X 1Ml (Contraceptive Injection For Im Use Only) , Single Blood Bags 350 Ml , Double Blood Bags 350 Ml , Triple Blood Bags 450 Ml , Quadruple Blood Bags 450 Ml , Double Blood Bag 450 Ml , Triple Blood Bags 350 Ml , Triple Blood Bag With Sagm 350 Ml , Triple Blood Bag With Sagm 450 Ml , Quadruple Blood Bag With Sagm 350 Ml , Quadruple Blood Bag With Sagm 450 Ml , Hiv Elisa (96 Test Each) , Hbsag Elisa (96 Test Each) , Hcv Elisa (96 Test Each) , Hiv Rapid (30 Test Each) , Hbsag Rapid (30 Test Each) , Hcv Rapid (30 Test Each) , Rpr/Vdrl (50 Test Each) , Reagents Anti-A, Anti-B, Anti-D Sera , Reagents Anti-Ab Serum , Reagents Antihuman Globulin Serum , Reagents Anti-A1 (Lectin) Serum , Reagents Bovine Albumin 22% , Aprepitant 80Mg (Kit Contains 3 Caps) , Aprepitant Kit 120 Mg , Bleomycin Injection 15 Mg, 15 Mg/Ml Vial , Capecitabine Tablet 500 Mg , Capecitabine Tablet 1000 Mg , Carboplatin Injection 150 Mg, 10 Mg/Ml Vial , Carboplatin Injection 450 Mg, 10Mg/Ml Vial , Cisplatin Injection 50 Mg, 1 Mg/Ml Vial , Cisplatin Injection 10 Mg , Cyclophosphamide Injection 1000Mg, 1.33Mg/Ml Vial , Cyclophosphamide Injection 500Mg, 10Mg/Ml Vial , Cyclophosphamide Tablet 50 Mg , Dacarbazine Injection 200 Mg, 10Mg/Ml Vial , Dacarbazine Injection 500 Mg , Docitaxel Injection 120 Mg, 20Mg/ 0.5 Ml Vial , Doxorubicin (Hydrochloride Powder) Aqueous Solution 10Mg/2Ml , Doxorubicin (Hydrochloride Powder) Aqueous Solution 50 Mg/ 2 Ml Vial , Epirubicin Injection 50 Mg, 2Mg/Ml Vial , Epirubicin Injection 10 Mg, 2Mg/Ml Vial , Etoposide Injection 100Mg, 20Mg/Ml Vial , Etoposide Capsule 50 Mg , 5-Fluorouracil Injection 500Mg, 50Mg/Ml Ampules , Fluorouracil Injection 1 Mg , Filgrastim Injection 300Mcg, 300Mcg/0.5 Ml Prefilled Syringe , Peg Filgrastim Injection 6 Mg , Geftinib Tablet 250 Mg , Gemcitabine Injection 200Mg, 100Mg/Ml Vial , Gemcitabine Injection 1000Mg, 10Mg/Ml Vial , Imatinib Tablet 400 Mg , Isophosphamide Injection 200Mg, 100Mg/Ml Vial , Lenalidomide Tablet 10 Mg , Letrozole Tablet 2.5 Mg , Oxaliplatin Injection 50Mg, 5Mg/Ml Vial , Oxaliplatin Injection 100Mg, 5Mg/Ml Vial , Paclitaxel Injection 260Mg, 10Mg/1.67 Ml Vial , Pemetrexate Injection 500Mg, 25Mg/Ml Vial , Tamoxifen Citrate Tablet 20 Mg , Tamoxifen Citrate Tablet 10 Mg , Vinblastine Injection 10 Mg, 1Mg/Ml Vial , Vincristine Injection 1 Mg, 1Mg/Ml Vial , Ateplase Injection 20 Mg , Ateplase Injection 50 Mg , Tenecteplase Injection 20 Mg , Rituximab Injection 500 Mg , Methotrexate Injection 50 Mg , Methotrexate Tablet 50 Mg , Zolidronic Acid Injection 4 Mg , Actinomycin Injection 0.5 Mg , Goserline Injection 10.8 Mg , Luperolide Injection 22.5 Mg , Degaralix Injection 240 Mg , Thalidomide Tablet 100 Mg , Exemestene Tablet 1 Mg , Sunitinib Tablet 50 Mg , Pazopanib Tablet 200 Mg , Dexamethasone Tablet 4 Mg , Dexamethasone Tablet 8 Mg , Erlotinib Tablet 100 Mg , Morphine Tablet 10 Mg , Morphine Tablet 30 Mg Special Repair , Buprinorphine Patch 5 Mg , Buprinorphine Patch 10 Mg , Buprinorphine Patch 15 Mg , Iohexol Injection 300 Mg , Zoledronic Acid Injection 4 Mg , Trastuzumab Injection 150 Mg , Trastuzumab Injection 450 , Onco Bcg Injection , Onco Bcg 80Mg Injection , Mitomycin Injection 40 Mg , Granisetron Injection 1 Mg , Leucovorin Injection 50 Mg , Bortezomib Injection 2 Mg , Ifosfamide Injection 1 Gm , Mesna Injection 400 Mg , Carfilzomib Injection 60 Mg , Bicalutamide Tablet 50 Mg , Sorafenib Tablet 200 Mg , Temozolamide Tablet 100 Mg , Temozolamide Tablet 250 Mg , Clindipine Tablet 10 Mg , Codon Set , Codon I/V Set Woth Air Vent & 0.2 Micron Filter , Granisetron Injection 3 Mg , Reteplase Injection 10.4 U(18.1 Mg) Kit , Meropenum Injection 125 Mg , Meropenum Injection 500 Mg , Piperacillin 1 Gm + Tazobactum 0.12Gm Injection , Piperacillin 4 Gm + Tazobactum 0.5Gm Injection,Vial Injection 4 Gm+ 0.5 Gm , Netilmycin Injection 25Mg/Ml , Ethamsylate Injection 250 Mg/2 Ml , Dns ( Sodium Chloride And Dextrose, Each 100 Ml Contains Dextrose 5 Gm, Nacl 0.9 G) , Calcium Syrup Each 5 Ml Contains Calcium 250Mg, Vitamin D3 125 Iu , Simyl Mct Oil (Medium Chain Triglycerides And Permitted Antioxidants (Tocopherol Accetate) , Ecg Electrodes (Neonate) , Umbilical Catheter No. 5, (5 Fr Length 37 Cm, -31Ml/Min Pvc , Umbilical Catheter No. 6 (6 Fr Length 37 Cm, -31Ml/Min Pvc , Oxygen Tubing, Suction Tubing (Different Colours) , Triway (Three Way Stop Clock) Lipid Resistant Pyrogen Free, Sterile, Latex Free , Bone Narrow Needle For Neonates 18 G , Blood Lancets For Glucometer , Grip Lock , Picc Line 24 G, 28 G , Suction Plain Catheter No. 6, Disposable Pyrogen Free , Suction Plain Catheter No. , 8 Disposable Pyrogen Free , Oxygen Hood For Neonates , T- Connector , Y- Connector For 8-10 Mm , Nasal Prongs Term & Preterm Single Patient Use With Twin Bore Nasal Pronges Sets, Extra Soft Medical Grade Nasal Tips , Nasal Prongs Preterm (Pead) 3.0 & 3.7 Mm - , Octopus Arc-Biannual Rate Contract Connector (Length 1-10 Cm 1.5*2.5, 2-10 Cm 1.5*2.8)Pur Vol- 0.57 Ml , Q-Way 6 Inches ,Sterlized Using Ethylene Oxide , Tegaderm 2, 3/8 Inch*2.3/4 Inch 6*7 Cm Tegaderm Tm Films Iv Transparent Film Iv Transparent Film Dressing Style(Latex Free) , Uro Bag (Neonates)- 100 Ml , Dyna Plast Adhesive Tape ( 10 Cm Width, 5 Cm Length) , Surfactant- Survanta(Synthetic)(25 Mg/1Ml), Exosurf (Bovine) , Micro Drip Set , Transpore 2 , Transpore 4 , Chest Drain (Adults) , Disposable Needle 24 , Anti Diptheria Serum , Td Vaccine , Erythromycin Tablet 250 Mg , Erythromycin Syrup 125 Mg/5 Ml, 60 Ml , Hepatitis B Vaccine (R Dna) I.P. , Urine Screening Through Dry Chemistry Rapid Testing Kit/Strips For Multiple Drug Uses:- 1. Morphine/ Opiates 2. Buprenorphine 3. Tramadol 4. D. Propoxyphene 5. Benzodiazepines Test Kit Kit , Nicotine Patches , 1.Nicotine Patches 7Mg 2. Nicotine Patches 14Mg , Nicotine Pastilles 2 Mg , Nicotine Pastilles 4 Mg , Tablet Vareniciline 0.5Mg , Tablet Vareniciline 1 Mg , Tablet Buspirone 5 Mg , Anti Rabies Vaccine Through Id Route, 1 Ml Vials Vaccine 1Ml. , Tenofovir 300 Mg+ Lamivudine 300 Mg Tablet , Dolutegravir Tablet 50 Mg , Dual Kits For Hiv And Syphilis - , Levofloxacin Tablet 250 Mg , Pyridoxine Tablet 50 Mg , Moxifloxacin Tablet 400 Mg , Cbnaat Tb Cartridges - , Cbnaat-Xdr Cartriges , Ethambutol Tablet 100 Mg , Ethambutol Tablet 400 Mg , Ethambutol Tablet 800 Mg , Clofazimine Tablet 100 Mg , Clofazimine Tablet 50 Mg , Cycloserine Capsule 250Mg , Delamanid Tablet 50 Mg , Bedaquiline (Bpq) - L Tablet , Ethinamide Tablet 250 Mg , Isoniazid Tablet 100 Mg , Isoniazid Tablet 300 Mg , 3 Hp Isoniazid Plus Rifapentine Fdc (300Mg/300Mg) Tablet , Rifapentine Tablet 150 Mg , Rifapentine Tablet 300 Mg , Rifampicin Tablet 150 Mg , Truenat Mtb Chips Test Kit , Truenat (Rip Chips) Test Kit - , Bbl Mgit Tubes For Use In Bactec Mgit 960 (7Ml) - 100 Tubes/Pkg Catalouge No 245122 , Bactec Mgit 960 Supplement Kit (100 Tests, Panta And Oadc Combined) Catalogue No: 245124 Kit - , Bactec Mgit 960 Sire Kit. One Kit Is Sufficient For 40 Test Catalogue No: 245123 , Genotype Mtbdr Si V2.0 96 Test 31796Am. Test Kits Composed Of 31796 A Genotype Mtbdr Si V2.0 - , Genotype Mtbdr Plus V2.0 30496 Am. Test Kits Composed Of 30496A Genotype Mtbdr Plus Version 2.0 And 51610 Genolyse - , Gt Blot 48 Reagent Kits , Genolyse 96 Test 51610 , 2Fdc (P) (H50 & R75) , 3Fdc Cp (A) (H75, R150 & E275) , 3Fdc (P) (H50, R75, Z150) , 4Fdc (A) (H75, R150, Z400 & E275) , Tablet Ethambutol 100 Mg 100 Mg , Rifampicin Tablet 300 Mg , Genolyse 96 Test 51610 - , Early Childhood Development (Ecd) Kit For Ashas - , Absorbant Cotton Gauze, 90 Cm X 18 Mtrs, Is No: 758:2023, Specification Mentioned Under Mdr-2017 As Amended From Time To Time ( 1X 5 Than) , Cotton Bandage Cloth, 15 Cm X 5 Mtrs, Is No. 863:1988, Specification Mentioned Under Mdr-2017 As Amended Time To Time, (1 X12 Rolls) , Cotton Bandage Cloth, 10 Cm X 4 Mtrs, Is No. 863:1988, Specification Mentioned Under Mdr-2017 As Amended Time To Time, (1 X12 Rolls) , Cotton Bandage Cloth, 5 Cm X 4 Mtrs, Is No. 863:1988, Specification Mentioned Under Mdr-2017 As Amended Time To Time, (1 X12 Rolls) , Crape Bandages Bp(1 X 10 Rolls) 10 Cm X 4.5 Mtrs , Crape Bandages Bp(1 X 10 Rolls) 15 Cm X 4.5 Mtrs , Plaster Of Paris Bandages B.P. (1 X 10 Rolls) 10 Cm X 2.7 Mtrs, (High Strength) , Plaster Of Paris Bandages B.P (1 X 10 Rolls) 15 Cm X 2.7 Mtrs, (High Strength) , Cotton Wool Ip 100 Gm , Cotton Wool Ip 500 Gm , Orthopadding Cast/Zigzag Cotton Roll 4 , Orthopadding Cast/Zigzag Cotton Roll 6 , Disposable Syringes 2 Ml, (24G), Ribbon Pack , Disposable Syringes 5 Ml, (23G), Ribbon Pack, Reuse Preventable , Disposable Syringes 10 Ml. With Needle, Ribbon Pack , Disposable Syringes 2 Ml, (23G), Ribbon Pack , Disposable Syringes 1 Ml (23G), Ribbon Pack , Disposable Insulin Syringe (31G), Ribbon Pack , Disposable Syringe 20 Ml With Needle, Ribbon Pack , Disposable Syringe 50 Cement Concrete With Needle, Ribbon Pack , Disposable Syringes 2 Ml, (24G) Reuse Preventable , I.V. Canulas 24 With Luer Lock , I.V. Canulas 22 With Luer Lock , I.V. Canulas 20 With Luer Lock , I.V. Canulas 18 With Luer Lock , I.V. Canulas 16 With Luer Lock , I.V. Canulas 26 With Luer Lock , I.V.Sets Disposable With Air Vent , Blood Administration Set/Blood Transfusion Set. Transparent Cylindrical Drip Chamber With 200 Micron Filter. 150 Cm Long Smooth Kink Resistant Tubing. , Pedeatrics Iv Drip Set With Air Vent , Sterile Disposable Spinal Needle For Single Use 23G X 3 1/2 Inch , Sterile Disposable Spinal Needle For Single Use 25G X 3 1/2 Inch Clear/ Transparent Hub , Sterile Disposable Spinal Needle For Single Use 22 G X 3 1/2 Inch Clear/ Transparent Hub , Sterile Disposable Spinal Needle For Single Use 24 G X 3 1/2 Inch Clear/ Transparent Hub , Sterile Disposable Spinal Needle For Single Use 26 G X 3 1/2 Inch Clear/ Transparent Hub , Sterile Disposable Spinal Needle For Single Use 18 G X 3 1/2 Inch Clear/ Transparent Hub , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +17D , Endotracheal Tube, Cuffed No. 5.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 5.0Mm - , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +18D , Endotracheal Tube, Cuffed No. 6.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 6.0Mm - , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +19D , Endotracheal Tube, Cuffed No.6.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 6.5Mm - , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +20D , Endotracheal Tube, Cuffed No. 7.0 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 7.0Mm - , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +21D , Endotracheal Tube, Cuffed No. 7.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 7.5Mm - , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +22D , Endotracheal Tube, Uncuffed No. 4.5 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 4.5Mm - , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +23D , Endotracheal Tube, Uncuffed No. 2.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 2.5Mm - , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +24D , Endotracheal Tube, Uncuffed No. 3.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 3.0Mm - , Hydrophobic Acrylic Foldable Iols In Preloaded Delivery System Optical Diameter 6Mm, Overall Length 12.5 Mm To 13.0 Mm, Optic Design Biconvex, 360 Degrees Square Edge And Aspheric Optics, Dioptric Range +25D , Endotracheal Tube, Uncuffed No. 3.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 3.5Mm - , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +17D , Endotracheal Tube, Uncuffed No.4.0 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 4.0Mm - , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +18D , Endotracheal Tube, Uncuffed No. 5.0 Specification: Sterile, Single Use,Medical Grade Pvc, Transparent,Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 5.0 Mm - , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +19D , Endotracheal Tube, Cuffed No. 5.5 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 5.5Mm - , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +20D , Endotracheal Tube, Cuffed No. 8.0 Specification: Sterile, Single Use, Medical Grade Pvc, Transparent, High Volume Low Pressure Cuff Towards The Distal End, Kink Resistant Inflation Tube, Murphy Eye At Distal End With Polished Smoothness, Radio-Opaque Line Throughout The Length, Standard 15 Mm Connector At Proximal End. Curved Blister Pack Suiting The Magill Curve. Internal Diameter: 8.0Mm - , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +21D , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +22D , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +23D , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +24D , Posterior Chamber Pmma Iol Optical Diameter 5.25Mm, Overall Length 12 Mm To 12.5 Mm, Optic Design Biconvex, 360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +25D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +17D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +18D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +19D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +20D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +21D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +22D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +23D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +24D , Posterior Chamber Pmma Iol Optical Diameter 6Mm, Overall Length 12.5 Mm, Optic Design Biconvex,360 Degrees Posterior Square Edge And Uv Protection Should Be There, Dioptric Range +25D , Infant Feeding Tube 4 , Infant Feeding Tube 5 , Infant Feeding Tube 7 , Infant Feeding Tube 9 , Infant Feeding Tube, Two Lateral Eyes At Distal End, Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa, With Female Flexible Mount With In-Built Closure, Radio Opaque Line, Sterile, Size: 6Fg , Infant Feeding Tube, Two Lateral Eyes At Distal End, Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa, With Female Flexible Mount With In-Built Closure, Radio Opaque Line, Sterile, Size: 8Fg , Infant Feeding Tube:Two Lateral Eyes At Distal End, Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa, With Female Flexible Mount With In-Built Closure, Radio Opaque Line, Sterile 10 Fg , Ryles Tube 8 , Ryles Tube 10 , Ryles Tube 12 , Ryles Tube 14 , Ryles Tube/ Nasogastric Tube (P.V.C) With Radio Opaque Lining. Size:16, Soft , Kink Resistant Pvc Tubing For Atraumatic Intubation, Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation, Four Lateral Eyes For Greater Efficiency, Radio Opaque Line, Marking At 50, 60, 70 Cm From Tip, Colour Coded Funnel, With Luer Connector/Closure, Length 105 Cm , Mucous Suction Trap , Foleys Catheter 8 , Foleys Catheter 10 , Foleys Catheter 12 , Foleys Catheter 18 , Foleys Ballon Catheter 2 Way ( Silicon Elastomer ) Non- Toxic Pyrogen Free Sterile For Single Use Only , Size 14, Single Sterile Packing , Foleys Ballon Catheter 2 Way ( Silicon Elastomer ) Non- Toxic Pyrogen Free Sterile For Single Use Only , Size 16, Single Sterile Packing , Urine Bag 2000 Ml, Single Unit Packing , Disposable Surgical Gloves No. 6.5, Isi Mark , Disposable Surgical Gloves No. 7, Isi Mark , Disposable Surgical Gloves No. 7.5, Isi Mark , Disposable Surgical Gloves No.6 , Isi Mark , Examination Gloves (Medium Size), Isi Mark , Micropore/Surgical Paper Tape 25Mm X 9.1Mtr. , Micropore/Surgical Paper Tape 50Mm X 9.1 Mtr. , Micropore/Surgical Paper Tape 75Mm X 9.1 Mtr. , Disposable Shoe Cover , Disposable Mask , Disposable Cap , Sterile Cord Clamp Non Toxic, Pyrogen Free Sterile For Single Use Only Single Unit Packing , Ecg Electrodes (Disposable Kit) Pack Of 6 , Ot Sponges With Radio-Opaque Thread (With 8 Layers 30 Cm X 30 Cm ) , Carbolic Acid 400 Ml , Opsite Eye Drape Sheet With Drain Pouch 70 Cm X 70 Cm , Blades For Eye Surgery Crescent , Blades For Eye Surgery Side Port 15° , Blades For Eye Surgery Keratones 2.8 Mm , Blades For Eye Surgery Implant 5.2 Mm , Karman/ Mtp Cannula No. 6, Single Unit , Karman/ Mtp Cannula No. 7, Single Unit , Karman/ Mtp Cannula No. 8, Single Unit , Mr Cannula No. 5 , Mr Cannula No. 6 , Mr Cannula No. 7 , Mr Cannula No. 8 , Disposable Sterile ,Powder Free Gloves For Eye Surgeries Surgical Gloves 6.5 No, Latex, Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) Size 6.5 , Disposable Sterile, Powder Free Gloves For Eye Surgeries Surgical Gloves 7 No, Latex, Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) Size 7 , Disposable Sterile, Powder Free Gloves For Eye Surgeries Surgical Gloves 7.5 No, Latex, Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) Size 7.5 , Ecg Paper 215 Mm*20 Mtr, Roll , Ecg Paper 50 Mm*20 Mtr, Roll , Ecg Paper 50 Mm*30 Mtr, Roll , Ecg Paper 60 Mm* 15 Mtr, Roll , Ecg Roll Big , Ecg Roll Small , Ecg Jelly 200 Ml Bottle , Ultrasound Jelly 200 Ml Bottle , Absorbable Gelatin Sponge, 80 X 50X 10 Mm, Single Unit , Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 6 Cm X 11 Cm (3 To 6 Units Of Mesh In One Box). , Macroporus Partially Absorbable Mesh With Polypropylene And Polyglecaprone 15 Cm X 15 Cm (3 To 6 Units Of Mesh In Each Box) , Multilayer Tissue Seprating Polyglecaprone Mesh (Polydioxanone And Macroporous Polypropylene) 10Cm X 15 Cm Oval (1 Foil In Each Box) For Lap Of Hernia (Should Be Antibacterial) , Multilayer Tissue Separating Mesh With Polypropylene/Polyster And Polydioxanone /Collegen. 15Cm X 15 Cm Square /Circular , Surgical Spirit Bp 500 Ml , Sodium Hypochlorite Solution 10% , Acetone 400 Ml , Dodecylbispropylene Triamine 9.2Gm, Didecyldimethyl Ammonium Chloride 13.0 Gm For Fogging , Ortho-Phthaldehyde 0.55% W/W Solution For Sterlization, 5 Liter , Potassium Peroxomonosulphate 50% W/W Containig Aldehyde Free Disinfectant , 5 Kg , Dark Eye Glasses , Disposable Eye Patch , I.O Dye (Rhex Id Dye) Each (Indigo Blue Dye) , Surgical Blades11 (Pack Of 100) , Surgical Blades15 (Pack Of 100) , Surgical Blades20 (Pack Of 100) , Surgical Blades23 (Pack Of 100) , Surgical Blades 24 (Pack Of 100) , Oxygen Venti-Mask (Pvc/Disposable)Adult , Oxygen Venti-Mask (Pvc/Disposable)Medium , Oxygen Venti-Mask (Pvc/Disposable)Paed. , Nebulisation Set (Mask With Tubing With Chamber (Adult ) , Nebulisation Set (Mask With Tubing With Chamber (Paediatric ) , Diaper Paediatric (Extra Small Size For Neonates) , Disposable Adhesive Cannula Fixator , Patient Identification Band Mother & Child Size (Different Colours) , Patient Identification Band Adult Size (Different Colours) , Patient Identification Band Paediatric Size (Different Colours) , Suction Catheter No. 10 , Single Unit , Suction Catheter No. 16 , Single Unit , Negative Suction Drain/Closed Round Drain 12 , Negative Suction Drain No.14 , Negative Suction Drain No. 16 , Disposable Plastic Urine Pan , Disposable Plastic Bed Pan , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 5X 6 Cm , Moisture Responsive With High Mvtr Grid Pattern Acrylic Adhesive Film With Non Woven Port Size 7X 9 Cm , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 6.5 Cm X 5 Cm (Pack Of 100) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 15.5 Cm X 8.5Cm (Pack Of 100) , Grid Pattern Acrylic Adhesive Film With Low Adherent Pad Having Mesh 25 Cm X 10 Cm , (Pack Of 100) , Skin Stapler Standard ( Single Unit) , Airway Set Size 2, ( Single Unit) , Airway Set Size 3, ( Single Unit) , Airway Set Size 4, ( Single Unit) , Airway Set Size 5, ( Single Unit) , Ambu Bag Adult, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 7 K Pa ( 70 Cm H2O Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 1300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) , Ambu Bag Ped, It Should Be Double Layered Resuscitator Within Built Pressure Limiting System That Prevents Airways Pressure From Exceeding 4 K Pa ( 40 Cm H2O Without Loss Of Valume. It Should Be Supplied With Reusable Transparent Breathing Face Mask , It Should Have Tidal Volume Max 300 Ml It Should Be Usfda And Iso/Ce Certified. (Single Unit) , Courtery Lead ( Single Unit) , Coutery Pad (Single Unit) , Lega Clip Size Lt 300 (Titanium Ligating Clips Medium Size Having Lateral And Transverse Grooves On The Inner Clips), (Single Unit) , Lega Clip Size Lt 400 (Titanium Ligating Clips Large Size Having Lateral And Transverse Grooves On The Inner Clips), (Single Unit) , Shoulder Immobilizer Standard , Pouch Arm Sling Standard , Centre Line , Cervical Collar Small Size (Soft) , Cervical Collar Medium Size (Soft) , Cervical Collar Large Size (Soft) , Hard Cervical Collar (Universal) Size , Chest Drain Catheter No.12 , Chest Drain Catheter No.14 , Chest Drain Catheter No.28 , Chest Drain Catheter No.32 , Chest Tube Drainage With Water Seal Bag No.28 , Chest Tube With Water Seal No.32 , Dj Stunt , Dj Stunt No.5.5 , Dj Stunt No. 6 French End Closed , Dj Stunt No 5/26 Both End Open , Dj Stunt No 6/26 Both End Open , Epidural Set , Guide Wire Teflon Coated J Tip , Guide Wire Teflon Coated V Straight Tip , Spc Set (Suprapubic Catheter Set) , Turp Loop , Skin Traction Set Standard Size , I.V. Flow Regulator Extension Sets , Blades For Eye Surgery Keratones 3.2 Mm , Balance Salt Solution (Bss For Eye Surgery) 500 Ml , Craner Wire Splint , Air Mattress , Bb Splint (Bohler- Braun) , Bed Side Pulley , Skeletal Traction , Disposable Needle 16 , Disposable Needle 23 , Disposable Needle 26 , Pmo Line , Troponin T, Sensitivity:-Not Less Than 95.8%, Direct Whole Blood Test Kit , 3D Mesh For Lap Ingunal Hernia A)Right Side B)Left Side - , Partial Absorble (10X6 Cm)Vicryl Mesh For Ipom , Tackers For Mesh Fixation (Non Absorable) , Measured Volume Fluid Infusion Set With 110Ml/150Ml Chamber - , Medical X-Ray Films(1X50) 8X10 , Medical X-Ray Films(1X50) 10X12 , Medical X-Ray Films(1X50) 12X15 , Medical X-Ray Films(1X50) 14X14 , Medical X-Ray Films(1X50) 14X17 , Agfa Cr Film (Dt2B)(1X100) 8X10 , Agfa Cr Film (Dt2B)(1X100) 10X12 , Agfa Cr Film (Dt2B)(1X100) 11X14 , Agfa Cr Film (Dt2B)(1X100) 14X17 , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R.B. Needle , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R.B. Needle , Catgut Suture (Chromic Catgut)Usp 1, 76 Cm X 63 Mm, 3/8 Circle (12 Foils In Each Box) Round Body Needle - , Chromic Catgut Absorbable Suture Usp 1,76Cm Length 1/2 Circle 40Mm, Round Body Needle (12 Foils In Each Box) , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle , Silk Sutupak Usp 1, 75 Cm (12 Foils In Each Box) , Silk Suture Usp 0, 76Cm X 45 Mm , 3/8 Circle Type Of Needle- Reverse Cutting (12 Foils In Each Box) , Silk Suture Usp 3-0, 90 Cm X 16 Mm , 3/8 Circle Type Of Needle- Cutting (12 Foils In Each Box) , Polyglactin (Violet) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box)Should Be Antibacterial , Polyglactin (Violet) Vicryl Usp-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) Should Be Antibacterial , Polyglactin (Violet) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box)Should Be Antibacterial , Polyglactin (Plain) Vicryl Usp-1, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle Reverse Cutting - , Polyglactin Synthetic Braided Absorbable Suture, Usp-1, 90Cm Length, Violet 1/2 Circle 40Mm Round Body Needle (12 Foils In Each Box) , Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) , Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied (12 Foils In Each Box) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle (12 Foils In Each Box) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body (12 Foils In Each Box) , Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied (12 Foils In Each Box) , Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting (12 Foils In Each Box) , Suture Absorbable Surgical Suture Usp (Synthetic) Polyglactin 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle.Should Be Antibacterial. , Knotless Control Device Polygecaprone 3/8 Circle Reverse Cutting Needle 24 Mm Spril Unidireectional 30Cm With Antibactreal Triclosan Coated 3/0 - , Knotless Control Device Polygecaprone 1/2 Circle , 40 Mm ,Taper Point,Ct,Unidirectional With Fixation Tab 30Cm With Antibactreal Triclosan Coated 1/0 - , Knotless Control Device Polygecaprone 1/2 Circle , 36 Mm ,Taper Point,Ct,Unidirectional With Fixation Tab 30Cm With Antibactreal Triclosan Coated 1 , Knotless Control Device Polygecaprone 1/2 Circle , 26 Mm ,Taper Point,Sh,Unidirectional With Fixation Tab 30Cm With Antibactreal Triclosan Coated 2/0 , Silver Alloy Non-Gamma-2 Lathe Cut Alloy , Mercury Pure Triple Distilled , Cavity Varnish 5% Sodium Fluoride , Calcium Hydroxide, Powder , Topical Fluoride Apf Gel 1.25% , Gum Paint , Edta 17 % Paste Form. , Pulp Devitalizer , Rubber Dam Kit , Air- Rotor Diamond Burs No. 1 (Inverted Bur) , Air- Rotor Diamond Burs No. 1 (Straight End Taper) , Air- Rotor Diamond Burs No. 1 (Round) , Air- Rotor Diamond Burs No. 1 (Straight) , Air- Rotor Diamond Burs No. 1 (Flame) , Air- Rotor Diamond Burs No. 2 (Inverted Bur) , Air- Rotor Diamond Burs No. 2 ( Straight End Taper) , Air- Rotor Diamond Burs No. 2 (Round) , Air- Rotor Diamond Burs No. 2 (Straight) , Air- Rotor Diamond Burs No. 2 (Flame) , Air- Rotor Diamond Burs No. 3 (Inverted Bur) , Air- Rotor Diamond Burs No. 3 ( Straight End Taper) , Air- Rotor Diamond Burs No. 3 (Round) , Air- Rotor Diamond Burs No. 3 (Straight) , Air- Rotor Diamond Burs No. 3 (Flame) , K-Files - Size- 15-40 , Length:-21 Mm , Should Have Rubber Stopper , K-Files - Size- 15-40 , Length:-25 Mm , Should Have Rubber Stopper , K- Files Size- 45-80, Length:-25 Mm, Should Have Rubber Stopper , K-Files Size- 6, Length :- 21 Mm , Should Have Rubber Stopper. , K-Files Size- 6, Length :- 25 Mm , Should Have Rubber Stopper. , K-Files Size- 8, Length :- 21 Mm , Should Have Rubber Stopper. , K-Files Size- 8, Length :- 25 Mm , Should Have Rubber Stopper. , K-Files Size- 10, Length :- 21 Mm , Should Have Rubber Stopper. , K-Files Size- 10, Length :- 25 Mm , Should Have Rubber Stopper. , Niti Hand Files (21 Mm) Size- 15-40, For Curved Canals , H-Files , Size-15-40 , Length :-21 Mm, Should Have Rubber Stopper , H-Files , Size-45-80, Length :-25 Mm Should Have Rubber Stopper , Matrix Strips,Made From A Thin, Strong, Flexible, Transparent Material Such As Mylar , Barbed Broaches , Made Of Stainless Steel, Can Be Sterilized Length ‰¥ 21 , Articulating Paper Strip, Red Colored With Sufficient Thickness Double Side , Articulating Paper Strip, Blue Colored With Sufficient Thickness Double Side , Matrix Band Retainer , No. 1 , Matrix Band Retainer , No.8 , Matrix Band , No. 1, Toflemire , Matrix Band , No. 8, Toflemire , Paper Point 25 , Paper Point 30 , Paper Point 35 , Mini Plates Isi/ Iso/Ce/Marked. , Arch Bar Length 1Feet Isi/ Iso/Ce/Marked. , Air Rotor Cartridges (Nsk) Supertorque, Standard Head Isi/ Iso/Ce/Marked. , Composite Finishing Kit- Disc Type , Composite Finishing Kit With 12 To 24 Finishing Point Of Different Shapes. The Durable Abbresive Points Are Autoclavabal And Cost Effective, Comprehensive Selection Of Plain For Finishing And Polishing In One Kit, For Fast And Efficient Finishing The Use Of Conjunction With The Composite Polishing Kit, Average Speed 5000 To 12000 Rpm Kit - , Iopa Film Size 30 Mm X 40 Mm , Iopa Film Size 31 Mm X 41Mm , Formocresol Formalin, Cresol Glycerin ,Formocresol Formalin Bp 20% V/V , Cresol Ip 32% V/V , Glycerin Ip Qs , Dental Chair Covering Sterilized Cling Foil Rolls Isi/ Iso/Ce/Marked. , Small Cotton Rolls For Isolation Isi/ Iso/Ce/Marked(Length-37Mm, Dia-8-10Mm) , Restroative Cement Type - Ii - (15 Gm Powder & 10 To 13 Gm Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Resistant To Demineralization,Hydrophylic Properties, Flouride Releasing, High Compressive Stregth, Low Solubility, Low Flexure Strength, Bonds To Both Dentin And Enamel. Shade :- Pale Yellow Powder & Liquid 15Gm Powder & 10 To 13 Liquid , Restroative Cement Type - Ii - (15 Gm Powder & 10 To 13 Gm Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Resistant To Demineralization,Hydrophylic Properties, Flouride Releasing, High Compressive Stregth, Low Solubility, Low Flexure Strength, Bonds To Both Dentin And Enamel. Shade :- Yellow Brown Powder & Liquid 15Gm Powder & 10 To 13 Liquid , Restroative Cement Type - Ii - (15 Gm Powder & 10 To 13 Gm Liquid), Strontium Based, Radiopaque Glass Ionomer With High Fluoride Release, Resistant To Demineralization,Hydrophylic Properties, Flouride Releasing, High Compressive Stregth, Low Solubility, Low Flexure Strength, Bonds To Both Dentin And Enamel. Shade :- Dark Grey Powder & Liquid 15Gm Powder & 10 To 13 Liquid , Pit & Fissure Sealant ( 6 Ml Bottle) Solution With High Flouride Releasing, Low Viscocity, High Retention, Rapid Cure & Low Solubility Liquid 6 Ml , Calcium Hydroxide , Paste System Based And Catalyst -Radiopaque, 4 Gm Paste 4 Gm , Zinc Phosphate Cement , 20 Gm Powder And 10 Ml Liquid Powder & Liquid 20 Gm Powder And 10 Ml Liquid , Glass Ionomer Cement- Type-Ix, High Strenth For Posterior Teeth, Chemical Setting Without Shrinkage, Strontium Based, High Flouride Releasing, 12 To 15 Gm Powder And 5 To 10 Gm Liquid Powder & Liquid 12 To 15 Gm Powder & 5 To 10 Ml Liquid , Hybrid Composite Resin For Anteriors (All Shades), High Strength, Long Lasting Wear Resitance, Great Handling Without Stick, 4 Gm Isi/ Iso/Ce/Marked. 4 Gm , Mineral Trioxide Aggregate, 0.5 Gm Isi/ Iso/Ce/Marked. 0.5 G , Flowable Composite 2 Mg Syringe, Flowable Consistancy Thicsotrophic, Low Shrinkage, Radiopaque, Easily Polishability, Should Be Hybrid, Wear Resistance, Syringe Design To Eleminate Bubbles 2 Mg , Niti Rotory Files 4%, 21 Mm (Pkt Of 6) Refill Pack Of(#15,#20,#25,#30,#35,#40) 21 Mm , Niti Rotory Files 4%, 25 Mm (Pkt Of 6) Refill Pack Of (#15,#20,#25,#30,#35,#40) 25 Mm , Niti Rotory Files 6%, 21 Mm (Pkt Of 6) Refill Pack Of( #15,#20,#25,#30,#35,#40) 21 Mm , Niti Rotory Files 6%, 25 Mm (Pkt Of 6) Refill Pack Of( #15,#20,#25,#30,#35,#40) 25 Mm , Crown Cutting Kit, Set Of 14 Burs - , Adhesive Resin Cement (Dual Lock Composite Resin Cement), 4.5 Gm Isi/Iso/Ce Marked Cement 4.5 Gm , Etchant 37% Phosphoric Acid ( 9 Ml Syringe) Solution , Root Canal Spreader 15-40, 21 Mm Isi/Iso/Ce Marked , Root Canal Spreader 15-40, 25 Mm Isi/Iso/Ce Marked , Gutta Percha Point No. 20, Isi/Iso/Ce Marked , Gutta Percha Point No. 25, Isi/Iso/Ce Marked , Gutta Percha Point No. 30, Isi/Iso/Ce Marked , Gutta Percha Point No. 15-40, Isi/Iso/Ce Marked , Gutta Percha Point No. 45-80, Isi/Iso/Ce Marked , Absorbent Point No.15-40, Isi/Iso/Ce Marked Packet Of 200 , Absorbent Point No.45-80, Isi/Iso/Ce Marked Packet Of 200 , Stainless Steel Wire 26G. Soft Isi/Iso/Ce Marked , Gates Glidden Drill No.1 , Gates Glidden Drill No.2 , Gates Glidden Drill No.3 , Pillow Cover Cotton Size:48 X 70 Cm, Color - Violet , Pillow Cover Cotton Size:48 X 70 Cm, Color - Indigo , Pillow Cover Cotton Size:48 X 70 Cm, Color - Blue , Pillow Cover Cotton Size:48 X 70 Cm, Color - Green , Pillow Cover Cotton Size:48 X 70 Cm, Color - Yellow , Pillow Cover Cotton Size:48 X 70 Cm, Color - Orange , Pillow Cover Cotton Size:48 X 70 Cm, Color - Peach , Bed Sheet Size-150 X 240 Cm, Color:Violet , Bed Sheet Size-150 X 240 Cm, Color:Indigo , Bed Sheet Size-150 X 240 Cm, Color:Blue , Bed Sheet Size-150 X 240 Cm, Color:Green , Bed Sheet Size-150 X 240 Cm, Color:Yellow , Bed Sheet Size-150 X 240 Cm, Color:Orange , Bed Sheet Size-150 X 240 Cm, Color:Peach , Ot Linen Poplin- Green Color, Size : 90 X 90 , Ot Linen Poplin- Green Color, Size : 90 X 140 , Ot Linen Poplin- Green Color, Size : 140 X 210 , Ot Linen Poplin- Green Color, Size : 90 X 90 (With Oval) , Ot Linen Poplin- Green Color, Size : 90 X 140 (With Circular Hole Of Size 10€ Diameters In Centers Green Color) , Ot Linen Poplin- Green Color, Size : 130 X 180 (With Circular Hole Of Size 10€ Diameters In Centers Green Color) , Ot Linen Cotton White 88X88 Cm. With Hole Size 9 X 10 Cm. In Centre And Should Be Folded And Stitched So There Are No Loose Ends. , Ot Gown Poplin Length 130 X 135 Cms Arm’S Length 58 X 60 Back Open Type With Provision Of Tying With String At Back Arm Should Have Elasting Cuff Or Cord For Tying At Cuff End. The Inside Of Gown Should Be Inter Lock So That There Are No Loose Threads , Patient Dress Kurta Payjama (Striped Blue) Small. Kurta Length 70 X 80 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) , Patient Dress Kurta Payjama (Striped Blue) Medium. Kurta Length 80 X 90 Cms Arm Length 22X 24 Cms.V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) , Patient Dress Kurta Payjama (Striped Blue) Large. Kurta Length 100 X 105 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) , Doctor Dress Kurta Payjama (Blue) Small. Kurta Length 70 X 80 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) , Doctor Dress Kurta Payjama (Blue) Medium. Kurta Length 80 X 90 Cms Arm Length 22X 24 Cms.V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) , Doctor Dress Kurta Payjama (Blue) Large. Kurta Length 100 X 105 Cms Arm Length 22X 24 Cms. V Shaped Neck Front With Buttons. Pajama Length 100 X 105 Cms (Poplin) , Towel 56 X 115 Cms. White Color , Dental Sheet Green Cotton 45 X 45 Cms. , Aprons (Lab Coats ) (Small) Full Size, Full Sleeves , Aprons (Lab Coats) (Medium) Full Size, Full Sleeves , Aprons (Lab Coats) (Large) Full Size, Full Sleeves , Legging Each Leg Poplin 40 X 40 Cms. Green Color Bottom Closed , Drape Sheet For Cssd 2 X2 Mtr. Cotton Cloth Grey Color , Kurta, Petticoat Sets Large Size , Green Strip , Glass Lonomer Silver Reinforced Isi/Iso/Ce Marked , Glass Lonomer Luting Cement Isi/Iso/Ce Marked , Rubber Dam Sheet Isi/Iso/Ce Marked , Sterilization Rolls For Packing Instrument 15Cm X 200Mtrs , Collagen Membrane-Sterile Bioresorbable Gtr Collagen Membrane Isi/Iso/Ce Marked , 6% Taper Gutta Percha Size 25 , 6% Taper Gutta Percha Size 30 , 6% Taper Gutta Percha Size 35 , 6% Taper Gutta Percha Size 40 , 4% Taper Gutta Percha Size 25 , Esthetic Fiber Post System , Pre Fabricated Metallic Post ( Cemented) , Pre Fabricate Metallic Post (Threaded) , Rubber Base Impression Material Addition Silicone Putty With Compatible Light Body 600-900Ml Putty With 50 Ml Light Per 300Ml Of Putty Isi/Iso/Ce Marked , Retraction Cord (Assorted Size Isi/Iso/Ce Marked , Bone Graft Material For Dental Purpose Isi/Iso/Ce/Marked , Surgical Bur Straight Fissure Carbide 1 Mm Isi/Iso/Ce/Marked , Surgical Bur Straight Fissure Carbide 1.5 Mm Isi/Iso/Ce/Marked , Surgical Bur Straight Fissure Carbide 2 Mm Isi/Iso/Ce/Marked , Resin Cement Isi/Iso/Ce Marked , Preadjusted Edgewise Stainless Steel Brackets Kit Containing Upper & Lower 2Nd Premolar To 2Nd Premolar Bondable Brackets With Upper Triple And Lower Double Weldable Buccaltubes,With Roth And Mbt Prescription And 0.022€And 0.018€ Slot (Leone/American Orth , Ni Ti Preformed Orthodontic Wire Round - 014 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Round - 016 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Round - 018 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Round - 020 Inch Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Rectangular -016X022 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Rectangular -017X025 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Ni Ti Preformed Orthodontic Wire Rectangular -019X025 Dimension (Leone/American Orthodontics/Tp Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Round 014 Inch (Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Round 016 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Round 018 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Round 020 Inch(Leone/American Orthodontics /Tp Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Rectangular 016X022 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Rectangular 017X025 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Stainless Steel Preformed Orthodontic Wire Rectangular 019X025 (Leone/American Orthodontics/T.P Orthodontics/Ormco/3M Unitek)Isi/Iso/Ce Marked , Blue Elastic Separators ( Leone/ American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked , Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Short Types Isi/Iso/Ce Marked , Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Long Types Isi/Iso/Ce Marked , Elastic E Chains (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Continous Types Isi/Iso/Ce Marked , Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Yellow Isi/Iso/Ce Marked , Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Blue Isi/Iso/Ce Marked , Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Green Isi/Iso/Ce Marked , Intra Oral Elastics (Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Red Isi/Iso/Ce Marked , Colourless O Rings (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Expansion Screw 3 Pin (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Preformed Molar Bands Without Buccal Tubesisi/Iso/Ce Marked , Bioplast Sheets Proprietary Item 2 Mm Thickness Isi/Iso/Ce Marked , Bioplast Sheets Proprietary Item 3 Mm Thickness Isi/Iso/Ce Marked , Stainless Steel Wire Spool ( Leone / Konark/Ss White) 19 Gauge Isi/Iso/Ce Marked , Stainless Steel Wire Spool ( Leone / Konark/Ss White) 20 Gauge Isi/Iso/Ce Marked , Stainless Steel Wire Spool ( Leone / Konark/Ss White) 21 Gauge Isi/Iso/Ce Marked , Stainless Steel Wire Spool ( Leone / Konark/Ss White) 23 Gauge Isi/Iso/Ce Marked , Tma Wire Lengths Rectangular - 017 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Tma Wire Lengths Rectangular - 019 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Tma Wires Preformed Rectangular- 017 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Tma Wires Preformed Rectangular- 019 X 025 Dimension (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marked , Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 6Mm Isi/Iso/Ce Marked , Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 7Mm Isi/Iso/Ce Marked , Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 8Mm Isi/Iso/Ce Marked , Orthodontic Micro Implants ( Leone /Dentos/T.P Orthodontics/Ormco/3M Unitek } 10 Mm Isi/Iso/Ce Marked , Forsus Fatigue Resistant Device( 3 M Unitek ), Proprietary Itemisi/Iso/Ce Marked , Powerscope 2 (American Orthodontics Proprietary Item)Isi/Iso/Ce Marked , Etchant 37% Phosphate Acid In Gel Form 2-4 Gm, Isi/Iso/Ce Marked , Loose Preadjusted Edgewise Mbt Bracket 022 Slot Isi/Iso/Ce Marked Per Bracket , Bondable Buccal Tubes Upper And Lower Right And Left 1St Molars .022€ Mbt With Upper Triple And Lower Double Slot (Desires/ Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked , Bondable Buccal Tubes Upper And Lower Right And Left 2Nd Molars .022€ Mbt (Desires/ Leone / American Orthodontics/T.P Orthodontics/Ormco/3M Unitek) Isi/Iso/Ce Marked , Ni-Ti Open Coil Spring0 10€X 030 (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek)Isi/Iso/Ce Marke , Niti Closed Coil Springs With Hooklets (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek 9Mm Isi/Iso/Ce Marked , Niti Closed Coil Springs With Hooklets (Leone / American Orthodontics/T.P Orthodontics/Ormco /3M Unitek 12Mm Isi/Iso/Ce Marked , Eugenol 110 Ml Isi/Iso/Ce Marked , Zinc Oxide Powder 110 Gram Isi/Iso/Ce Marked , Naoci 5.25% Solution Isi/Iso/Ce Marked , Fiber-Reinforced Splinting Material- Bondable Reinforced Ribbon Fiber-Approx. 2Mm Width Isi/Iso/Ce Marked , Fixer & Developer Solution Set (Manual) To Make 13.5 Lt Solution Each Of Fixer And Developer Isi/Iso/Ce Marked , Air Rotor Spray Isi/Iso/Ce Marked Bottle , Disposable Patient Drape Sheets Size 1X1 Mtrs. , Single Use Syringes 10 Ml With Needle 23 G. X 1€ Length Sterile Isi/Iso/Ce Marked , Single Use Syringes 5 Ml With Needle 23 G. Sterile 1€ Length Isi/Iso/Ce Marked , Single Use Syringes 2 Ml With Needle 23 G. Sterile 1€ Length Isi/Iso/Ce Marked , Single Use Insulin Syringes With Needle Sterile Isi/Iso/Ce Marked , B.P. Blade Size 11 Isi/Iso/Ce Marked , B.P. Blade Size 15 Isi/Iso/Ce Marked , B.P. Blade Size 23 Isi/Iso/Ce Marked , Silk Suture Material (3-0) , N-95 Respirator Mask(Covid) , Ppe Kit(Covid) , Vtm Media(Covid) , Triple Layer Mask(Covid) , Hydroxy Chloroquine Tablet 200 Mg(Covid) , Lysol(5L)(Covid) , Sodium Hypochlorite(5L)(Covid) , Oxygen Cylinder(Covid) , Real Time Pcr Kit(Covid) , Covid19 Igm/Igm Rapid Test (Wondfo Sars-Cov-2 Antibody Test)(Covid) , Dead Body Cover(Covid) , Rapid Screening Kits For Covid-19 Test(Covid) , Denture Spirit-Surgical Spirit With Methyl Salicylate, Diethyl Phthalate And Caster Oil Dentured Alchol, 500 Ml Bottle(Covid) , Disposable Bed Sheet(Covid) , Thermal Scanner(Covid) , Tab Levocetrizine 5 Mg(Covid) , Spun Bond Non-Woven 3 Ply Face Covers(Covid) , Magna Pure 24 Total Na Isolation Kit, Pack Size-96(Covid) , Magna Pure 24 Processing Cartridge, Pack Size-48(Covid) , Magna Pure 24 Tip Ptark (Comes With Pierecing Tools)Pack Size-48(Covid) , Magna Pure Tip 1000 Ul, Pack Size-3840(Covid) , Framestrips With Flat Caps High Profile, Pack Size-120(Covid) , Magna Pure Sealing Foil,Pack Size-100(Covid) , Mplct Na Isolation Kit- Lysis/ Binding Buffer Refill, Pack Size-100Ml(Covid) , Handsanitizer (500 Ml)(Covid) , Framestrip With Flat Caps-Low Profile(Covid) , Magna Pure 96 External Lysis Buffer(Covid) , Light Cycler -480 Multiwell 11 Plate 96(Covid) , Light Cycler 8-Tube Strip Adapter Plate(Covid) , Manual Rna Extraction Kit-50 Test(Covid) , Oseltamivir 75 Mg , Covid Kavachâ„¢ Anti- Sars Cov-2 Igg Antibody Detection Elisa (96 Micro Well Coated Plate , Tocilizumab Injection 400 Mg/20 Ml(Covid) , Standard Q Covid19,Ag Test(Rapid Antigon Test) , Lc Prep Lysi/Bind Buff Dna,Mbp , Ramdesivir Injection 100Mg , Hydroxychlorine Tablet 400 Mg(Covid) 400 Mg , Dexamethasone 6 Mg Tablet(Covid) 6 Mg , Enoxaparin 40 Mg Injection(Covid) 40 Mg , Favipiravir(Covid) 400 Mg , Coronil Kit Coronil Kit Each Contains(80Tab+80Tab+20Ml) , Ayush Kwath Powder , Amphotericin B Powder For Injection 50 Mg Liposomal Complex,Vial Injection Powder 50Mg/Ml, 10Ml Vial , Tocilizumab 80 Mg , Oxygen Regulator With Humidifier Bottle,Rotameter And Key For B And D Type Cylinders , Disposable Ad Syringes 0.5Ml. , Nitrile Gloves(Large Size),Purple,Powder Free,Box Of 100 Pcs , Nitrile Gloves(Medium Size),Purple,Powder Free,Box Of 100 Pcs , Nitrile Gloves(Small Size),Purple,Powder Free,Box Of 100 Pcs , Tablet Posaconazole 100 Mg , Intravenous Immunoglobulin(Ivig) 10 Gm,100 Ml Bottle , Sars-Cov-2 Sequencing Kits Test Kit Kit , Corbevax Vaccine,10 Ml Vial , Zinc Oxide Cream 10% 10 Gm , Zinc Oxide Powder 100 Gm , Zinc Phosphate Cement , Powder And Liquid , Zinc Sulphate Dispersible Tablet 20 Mg , Zinc Sulphate Syrup 60 Ml , Zoledronic Acid Injection 4 Mg , Balloon Tamponade (Standard Size) , Miracle Mix(Standard Size) , Bonding Agent , Endo Files(Standard Size) , Orafill(Standard Size) , Pain Off(Standard Size) , Composite Syringes A1(Standard Size) , Composite Syringes B1(Standard Size) , Lignocaine Spray , Dycal(Standard Size) , Metapex(Standard Size) , Restoration Bonding Agent , Mixing Pad(Standard Size) , Coe-Pack(Standard Size) , Temephos 50% 1 Ltr , Pyrazinamide 500 Mg Tablet , Pyrazinamide 750Mg Tablet , Rifampicin 150 Mg Capsule , Rifampicin 300 Mg Capsule , Rifampicin 450 Mg Capsule , Isoniazid 300 Mg Tab. , Isoniazid 100 Mg Tab. , Ethanbutol 800 Mg Tab. , Ethanbutonl 400 Mg. Tab. , Ethanbutol 100 Mg Tab. , 4 Fdc (A) , 3 Fdc (A) , Inj. Streptomycetin 0.75 Gm , 3 Fdc Ped. (P) , 2 Fdc Ped. (P) , Pas Poder , Iec Jel Pack , Tharmocal Box , Falcon Tube 50 Ml , Tab. Pyridoxin 50 Mg , Inj. Kanamicine 18 M , Tab. Cyclocerin 500 Mg , Tab. Cyclocerin 250 Mg , Tab. Ethonamlde 250 Mg , Tab. Uvezolld , Tab. Clofazimine 100 Mg , Tab. Coprpcomycine 1 Mg , Tab. Delamanid 50 Mg , Tab. Moxifloxacin 400 Mg , Multi Drug Urine Screen Kits , Cotton Bandages(1 X 12 Rolls) 10 Cm X 4 Mtrs , Cotton Bandages(1 X 12 Rolls) 15 Cm X 5 Mtrs , Cotton Bandages(1 X 12 Rolls) 5 Cm X 4 Mtrs , Cotton Gauze Cloth(1 X 5 Than) 90 Cm X 18 Mtrs , Cotton Wool Ip 100 Gm , Cotton Wool Ip 500 Gm (Net) , Cotton Wool Ip 500 Gm , Disposable Cap , Disposable Surgical Gloves No. 6.5, Isi Mark , Disposable Surgical Gloves No. 7, Isi Mark , Disposable Surgical Gloves No. 7.5, Isi Mark , Disposable Surgical Gloves No.6 , Isi Mark , Disposable Syringe 20 Ml With Needle, Ribbon Pack , Disposable Syringe 50 Cement Concrete With Needle, Ribbon Pack , Disposable Syringes 1 Ml (23G), Ribbon Pack , Disposable Syringes 10 Ml. With Needle, Ribbon Pack , Disposable Syringes 2 Ml, (23G), Ribbon Pack , Disposable Syringes 2 Ml, (24G), Ribbon Pack , Disposable Syringes 5 Ml, (23G), Ribbon Pack, Reuse Preventable , Disposable Sterile Powder Free Gloves For Eye Surgeries Surgical Gloves 6.5 No Latex Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Puncture Resistant, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) , Disposable Sterile Powder Free Gloves For Eye Surgeries Surgical Gloves 7 No Latex Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Puncture Resistant, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) , Disposable Sterile Powder Free Gloves For Eye Surgeries Surgical Gloves 7.5 No Latex Powder Free, Polyurethane Coated, Brown Colored, Gamma Irradiated Surgical Gloves. Absence Of Common Allergens, Puncture Resistant, Antislip, Smooth Finish, Anatomical Fit, Beaded Cuff, Endotoxin Concentration As Per Fda Guidelines And Ce Certified. (Single Unit) , Disposable Shoe Cover , Disposable Insulin Syringe (31G), Ribbon Pack , Disposable Mask , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size 2-0, ½ Circle R.B. Needle , Suture Absorbable Surgical Suture Usp (Catgut-Chromic) 76 Cm X 30 Mm, Size1-0, ½ Circle R.B. Needle , Suture Absorbable Surgical Suture Usp (Synthetic) Polyglactin 90 Cm X 30 Mm, Size -2-0, ½ Circle Round Bodied Needle , Suture Catgut 3-0No. R.B. Needle , Suture Non-Absorbable Surgical Suture Usp (Braided Silk Black) 76 Cm X 45 Mm, Size -2-0, 3/8 Circle Reverse Cutting Needle , Suture Silk 2-0No. R.B. Needle , Polyglactin (Plain) Vicryl Usp-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) , Polyglactin (Plain) Vicryl Usp-1, 90 Cm X 40 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) , Polyglactin (Plain) Vicryl Usp-3-0, 70 Cm X 20 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 26 Mm 1/2 Circle, Type Of Needle- Oval Round Body (12 Foils In Each Box) , Polyglecapron Antibacterial Suture: Usp 2-0, 70 Cm X 31 Mm 1/2 Circle, Type Of Needle- Round Body Medium Half Circle (12 Foils In Each Box) , Polymide Suture Usp 0, 1.5 M X 40 Mm Half Circle Type Of Needle- Round Bodied (12 Foils In Each Box) , Polymide Suture Usp 3-0, 70 Cm X 26 Mm, 3/8Circle Type Of Needle- Reverse Cutting (12 Foils In Each Box) , Polypropylene Suture Usp -1, 70 Cm X 40 Mm, 1/2 Circle Type Of Needle- Heavy Round Bodied (12 Foils In Each Box) , Polypropylene Suture Usp -2-0, 90 Cm X 30 Mm, 1/2 Circle Type Of Needle- Round Bodied (12 Foils In Each Box) , Stadiometer , Wooden Stick (Oral Examination) , Bp Appratus , Weighing Machine (Digital) , Acetic Acid 100% , Swab Sticks For Vig Examanation , Torch , Mouth Mirror , Disttled Water , Wooden Tongue Depressor , Mantoux Test , Albumin (5X50Ml) , Alkline Phosphtase 4X24 + 4X6Ml) , Bilirubin Kit 4X60Ml) , Cholestrol Kit 5X30Ml) , Creatinine Kit (4X60M)L , Ggt (5X6.5Ml) , Glucose Kit (5X60Ml) , Hdl Kit (4X30Ml + 4X10Ml) , High Control For Semi Auto (1X5Ml) , Normal Control For Semi Auto (1X5Ml) , Sgot Kit (4X24Ml + 4X6Ml) , Sgpt Kit (4X24Ml + 4X6Ml) , Total Protein (5X50Ml) , Triglycerides Kit (4X24Ml + 4X6Ml) , Urea Kit (4X24Ml + 4X6Ml) , Uric Acid Kit (4X24Ml + 4X6Ml) , Wash Kit (4X50Ml) , Reagent For Fully Automatic Bio-Chemistry Analyser Bs400 Which Must Be In Liquid State Stable Form , Alkaline Phosphate 8X50 / 8X12.5Ml , Amylase 4 X 20 Ml/ 2 X 10 Ml , Bilirubin Total 8X50 / 8X12.5Ml , Bilirubin Direct 8X50 / 8X12.5Ml , Cholestrol 8X50Ml , Crp Fs 1X20 / 1X10Ml , Ck - Nack 4 X 20 Ml/ 2 X 10 Ml , Cpk - Mb 4 X 20 Ml/ 2 X 10 Ml , Creatinine 8X50 / 8X12.5Ml , D-Dimer 2X12Ml + 1X8Ml , Ferritin 2X20 / 1X10Ml , Glucose 8X50/8X12.5Ml , Hdl 4X20 / 2X10Ml , Hba1C 2X15 / 1X10 / 1X5Ml , Hba1C 3X20/ 2X10 / 1X10Ml , Hemolyzing Solution 500 Ml , Iron Tibc 4X20 / 2X10 , Ldh 8X50Ml + 8X12.5Ml , Ldl 4X20 / 2X10Ml , Lipase 4X20 / 2X10Ml , Ra Factor 2X20 / 1X8Ml , Acetec Acid 5% , Tablet Chlorine , Capillary Tubes , Card For Haemo Spot , Centrifuge Tube Stand 15 Ml(10*2) , Centrifuge Tube Stand 50 Ml(15*2) , Conical Flask 500 Ml , Coplin Jars , Covid Elisa Antigen Kit (Icmr Approved) , Crp 50 Test Kit (Qualitative) , Cryo Box With Lid , Cryo Vials 2 Ml , Cup For Bs400 Chemistry Analyzer , Diamond Marking Pencils , Disposable 3 Ply Mask , Disposable Alcohol Swab , Disposable Cap , Disposable Esr Pipette , Disposable Esr Tube (Westergen Method) , Disposable Gown , Disposable Shoe Cover , Distilled Double Dionized Water 5 Ltr , Distilled Triple Dionized Water 5 Ltr , Distilled Dionized Water 5 Ltr , Drums Tube , Ecg Jelly/Usg Jelly , Edta Vial (Non Vacuum) , Edta Vial (Vacuum) , Eppen Drop Vial ( Mct ) , Esr Black Vial (Non Vacuum) , Esr Black Vial (Vacuum) , Esr Stand , Face Shield , Falcon Tube Rack , Falcon Tube (All Size) , Filter Paper , Filter Tip 100 Micro Litre (1*960) , Filter Tip 20 Micro Litre (1*960) , Filter Tip 10 Micro Litre (1*960) , Filter Tip 200 Micro Litre (1*960) , Filter Tip 5 Micro Litre (1*960) , Floride Vial (Non Vacuum) , Floride Vial (Vacuum) , Gel Iec Pack , Glass Bottel Round , Glass Cover Slip 22 Mm , Glass Pipette 10Ml , Glass Pipette 2Ml , Glass Pipette 5Ml , Glass Slide , Glucostix 50 Sticks , Hand Sanitizer 5 Ltr (Ip Base) , Hb Pipette , Hb Tube , Hbsag Card , Hcv Rapid Card , Hiv Rapid Card , Insulated Sample Transportation Box , Lancet (Auto Destroyable/Safety Lancet) , Lancet (Twisted Round) , Leucoreduction Filter , Malaria Antigen Card , Mct Vials 1.5Ml , Mct Vials 2.0Ml , Measuring Cylender 20Ml , Measuring Cylender 100Ml , Measuring Cylender 500Ml , Measuring Cylender 1000Ml , Microscope Cover Glass 22 X 40 Mm , Multistix , N/10 Hcl 500Ml , Parafilm Tape , Pastuer Pipette , Ph Paper 5.0 To 7.5 , Plain Vial (Non Vacuum) , Plain Vial (Vacuum) , Ppe Kit (Citra & Drda Approved) , Pregnancy Cards , Ra Factor 50 Test Kits , Reversible Rack Mct , Rubber Teat For Pipette , Slide Storage Rack , Slide Storage Tray Pvc , Sodium Citrate Vials Non Vaccum , Sodium Citrate Vials Vaccum , Sodium Hypochloride 5 % 5 Ltr , Sst Vials Non Vaccum , Sst Vials Vaccum , Steel Rack For Test Tube 48 Hole , Sterile Swab Stick , Sterlum 500Ml , Stickers For Slide (Per Piece) , Test Tube Glass 12*100 , Test Tube Glass 12*75 , Test Tube Glass 15*150 , Test Tube Glass 25*150 , Test Tube Stand 1X 10 Slots , Test Tube 1X 30 Slots , Thermocol Box , Thermal Paper Roll , Tissue Paper Roll 20 Meter , Tourniquate , Sample Cup With Label (3 Screw, Sterile)/ Sputum Cup , Uristix 100 Strips , Vaccutainer , Vaccutainer Needle , Vtm Swab Stick (Standard Size) , Washing Brush . For Test Tube (Standard Size) , Widal Kit (Slide Method) , Wipes 1*280 Pc Lab Grade , Yellow Tips 1X1000 Nos , Zip Lock Pouch For 1 Ltr , Anti-D Igg 10 Ml , Anti-D Igm 10 Ml , Copper Sulphate Powder 500Gm , Dpx Mount , Ethanol Absolute , Fouchet Reagent , Giemsa Stain 125 Ml , Glacial Acetic Acid , H & E Stain (Haematoxillin Stain) , J.S.B 1 Stain , J.S.B 2 Stain , Lieshmen Powder 25 Gm , Lugal Iodine 125 Ml , Manual Rna Extraction Kit 50 Test (Icmr Approved) , Mathenol 2.5 Ltrs , Naoh Sodium Hydroxide , Oil Immersion 25Ml , Rapid Pap Stain Kit , Rapid Test Kit Igg, Igm, Ns1 For Dengue , Rtpcr Kits 96 Test For Covid-19 (Icmr Approved) , Siprit , Sodium Chloride , Sodium Dehydrogen Orthophosphate , Sodium Hydrogen Orthophosphate , Sodium Hypochloride 10% , Sulphar Powder 500 Gm , T3 Elisa (96 Test) , T4 Elisa (96 Test) , Tsh Elisa (96 Test) , Xylene , Anti Ab , Anti D ( Igg+ Igm) , Anti Human Sera/ Coombs Sera , Blood Grouping Plate , Bovine Albumin , Single Blood Bag 350 Ml , Triple Blood Bag 450 Ml , Double Blood Bag 350 Ml(Sagm) , Double Blood Bag 350 Ml , H.I.V Elisa 4Th Generation (96 Test) , Hb Strips , Hbsag Elisa 4Th Generation (96 Test) , Hcv Elisa 4Th Generation (96 Test) , Quadraple Blood Bags 450Ml , Single Blood Bag 350Ml , Vdrl Card , Absolute Alcohol 95% (500 Ml) , Acetone (500Ml) , Hiv Tridot Rapid Cards , Biological Indicator , Bunsen Burner , C.L.E.D Agar 500Gm , Carbol Fuchsin Powder (25 Gm) , Carbol Fuchsin (125 Ml) , Carbolic Acid 500Ml , Chemical Indicator , Concave Slide , Conical Flask 500Ml , Crystal Violet (125 Ml) , Cyto Brush With Spatula (100 Piece) , Glucose Broath , Gram Iodine Solution (125 Ml) , Haematoxylene Stain , Hydrogen Peroxide 3% (500Ml) , Indicator Tape For Steam Autoclave Process Verification , Kovacs Indole Reagent (100 Ml) , Lactose Monohydrate (500 Gm) , Leucoreduction Filter , Liquid Broath , Mac Conkey Agar 500Gm , Mac Conkey Broth Double Strength 500Gm , Methylene Blue 25 Gram (Powder) , Motility Test Medium , Mr Vp Medium 500Gm , Muller Hinton Agar 500Gm , Ph Strips , Sulphuric Acid 98.9% (500 Ml) , Xld Agar 500 Gm) , Xylose Lysine (100 Gm) , Young Broath Culture , Alp Kit , Aso Kit , Capillary Tubes For Ct(Pkts) , Cover Slip(Pkt.) Large(Pkts.) , Cover Slip Small (Pkts.) , Crp Kit , Diamond Pencil , Edta Vacutainer , Esr Tube , Filter Paper For Bt(Pkts) , Formalin (Ltrs.) , Glass Slide , Glucostrips , Grams Stain , Hemoglobin Strips/Hemoque , Ketac-Molar , Leishmans Stain , Lens Cleaner , Levolin Respules , Lugols Iodine , Mgg Giemsa Stain , Pap Smear Spectulla & Cyto Brush , Ph Strips(Pkts.) , Plain Vacutainer , Plastic Container For Urine , Pm Kits , Ra Kit , Rapid Pep Stain Kit , S.Albumin Kit , S.Calcium Kit , S.Protein , Semen Diluting Fluid (Bottles) , Sugar Kit , Suture (10.0) F 3719 Nylon , Toluidene Blue(500Ml.) , Torniquet , Tsh Card , Widal Kit , Zn Stain Kit , Micro Tips Large , Orthotoluedine Solution , Uristic , Lq080 10 Ml Cooked M Medium (10 Ml X 25) , Sterile Individual Packed Cotton Swabs , Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 0-10Ul , Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 0-20Ul , Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 0-200Ul , Sterile Aerosol Barrier Pipette Tips Racked 1 Box (1X 96) 100-1000Ul , Skirted Pcr Plate (96 Wells) , Sterile Transparent Sealant For Pcr Plate (96 Well) , Pcr Kits For Covid 19 Testing Compatible With Biorad Pcr , Mac Conkey Both Purple Single Strength W/ Bcp Media M 083 , Mac Conkey Both Purple Double Strength W/ Bcp Media M/96 , Elisa Ns1 Dengue Kit (96 Test) , Auromine - O (Per Gm) Powder , Broom Stick Stirrer(Pkt 100) , Heparin Lithimum Tube , Pernament Marker Pen Black , Methanol 5Ltr , Zip Lock Bag 20X25 Cm , Hydrochloric Acid (Mw36.46 ) , Slide Box (100 Slide Per Box) , Biohazard Symbol (Red) , Phenol Cristal , Cello Tape (5 Cm) , Potossium Permagnent (Kmno4) Cristal 50 Gm , Spirit Lamp , Spirit Alochloic , Squize Bottle (Small) , Squize Bottle (Big) , Ruber Band , Temp. Humidity Meter , Weighinj Scale Degital , Perafilm , Brosile Zar 5 Ltr , Brosile Zar 3 Ltr , Brosile Zar 500 Ml , Mac Conkey Broth Purple Single Strength W/ Bcp (Hi Media M083 1(500Gm.) , Mac Conkey Broth Purple Double Strength W/Bcp (Hi Media M 796 1(500 Gm.) , Ria- Tubes , Plastic Tube With Cap 2 Ml , Plastic Tube For Calcium Test , Bp Apparatus Digital , Bp Apparatus Marcury , Weighinj Scale For Blood Unit , Stethoscope , Dengue Ns1 Rapid Test Card , Dengue Igm+Igg Combo
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 11
8.
Railways #11019170 AOC
Tender For Electromagnetic Crack Detector With Loading & Unloading System For Testing Of Axles For Vande Bharat Bogies And Other Coach Axles [ Warranty Period: 30 Months After The Date Of Delivery ] , Charges For Comprehensive Amc For Year 1, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 1 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 3 8347N003 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 2, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 4 8347N004 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 3, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 3 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers Page 1 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 5 8347N005 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 4, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 4 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 6 8347N006 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 5, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 5 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery / Completion Rate Of Supply For All Items Completion : Within 220 Days As Per The Delivery Chart At Class 7 And 8 At Technical Specification Attached. Payment Terms S.No Description Payment Terms 1 80% Payment Will Be Released After Successful Commissioning And Proving Out Of The Machine. After Successful Performance Test For One Month Remaining 20% Payment Will Be Released Subject To Submission Of Bank Guarantee / Warranty Guarantee Bond For An Amount Of 10% Of Contract Value Towards Warranty Performance / Warranty Security Valid Beyond Six Month Period Of Warranty. Penalty May Be Levied For Delay In Commissioning Of The Equipment By The Bidder As Per Relevant Gcc Conditions. The Bank Guarantee / Warranty Guarantee Bond Will Be Returned To The Supplier After Warranty Period By Detecting Any Penalty, If Levied. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State / Central Governments In Respect Of The Items Stipulated In The Contract ( And Not The Raw Materials Thereof ) , Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax / Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His Offer The Rate Of Tax / Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier / Contractor. Railway Standard Fall Clause S.No Description 1 Not To Be Included Standard Governing Conditions Page 2 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 S.No Description 1 Applicable As Detailed In This Tender Document And In Icf Bid Document, Special Conditions / Annexures Attached With The Tender Document ( If Any ) , And Conditions Mentioned In Technical Specification / Str / Drawings Uploaded Along With This Tender. For Contracts, Irs Conditions Of Contract Wherever Specifically Not Modified In The Above Said Documents Shall Apply. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderer Shall Be A Reputed Manufacturer In The Subject Field. Yes Yes Allowed ( Mandatory ) 2 I ) Tenderer Should Have Supplied At Least 01 No. Of Emcd Machine For Yes Yes Allowed Testing Railway Axle To Govt. / Public Sector / Mncs / Reputed Private ( Mandatory ) Companies. Or Ii ) Tenderer Should Have Supplied At Least 05 Nos. Of Similar Capacity Machines With Minimum 10000Amps In The Past Five Years To Railways And Other Govt. Sectors / Public Sector / Mncs / Reputed Private Companies. Proof For Supply ( Purchase Order, Commissioning And Performance Certificate To Be Attached As Per Annexure A Clause 2 ) . 5. Compliance Conditions Check List S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 In Case Of Indigenous Bidders, Whether You Are Large Scale Industry Or No No Not Allowed Consortia Of Mses Formed By Nsic, If Yes, Have You Indicated Quantum Of Sub Contracts Given To Micro And Small Enterprises ( In Percent Of Order Value ) ? 2 Have You Gone Through The Eligibility Criteria And Submitted All The No No Not Allowed Documents Mentioned Therein? 3 Have You Submitted The Emd Or Bid Securing Declaration As Per Clause 6.0 No No Not Allowed Of Section-I Of Instructions To Tenderers Of Icf Bid Document Version 09. 4 Have You Furnished Financial Capacity As Per Clause 9.2.1 ( Iii ) Of Section-I Of No No Not Allowed Instructions To Tenderers Of Icf Bid Document Version 09. 5 Have You Confirmed For Compliance Of Public Procurement Orders Of No No Not Allowed Department Of Expenditure Regarding Countries Sharing Land Border With India? 6 Have You Submitted The Details Of Location ( S ) At Which Local Value Addition No No Not Allowed Is Made / Proposed? 7 In Case Of Non-Local / Class-Ii Suppliers, Have You Submitted Road Map For No No Not Allowed Setting Up Manufacturing Facilities For Tendered Item Along With The Offer? ( This Is Applicable Only For Items Which Are Not Restricted To Class-I Local Suppliers ) . 8 Have You Submitted Self-Declaration With Respect To Non Debarment Under No No Not Allowed Any Provisions Of Dpiit Rules? 9 Have You Submitted Translated Copy Into English, For All Documents In No No Not Allowed Language Other Than English And All Such Documents Should Be Signed By The Authorised Translator And Notarized In India? 10 Have You Submitted Declaration For Passing On The Input Tax Credit As Per No No Not Allowed Para 2.8 And 2.9 Of Section-Ii Of Icf Bid Document Version 09. 11 Have You Submitted Authenticated Copy Of The Document Authorizing The No No Not Allowed Signatory To Submit Offer And Commit On Behalf Of Tenderers? 12 Have You Furnished The Statement Of Deviations ( Preferably Nil ) ? No No Not Allowed Page 3 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 13 Have You Furnished The Statement Of Equipment & Quality Control? No No Not Allowed 14 Have You Kept Your Offer Valid For The Validity Period As Mentioned In Nit No No Not Allowed Header? Commercial-Compliance S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Firm Should Furnish Gst No. And Hsn Code No. In Their Offer. Yes Yes Allowed ( Mandatory ) 2 The Tenderers Must Submit Emd As Detailed Under Yes Yes Allowed Clause -6 Of Instructions To Tenderers. Tenderers ( Optional ) Seeking Exemption From Payment Of Emd Must Upload The Requisite Documentary Evidence In Support Of Their Claim For Exemption From Payment Of Emd Along With The Offer. Any Offer Either Not Accompanied With A Vaild Exemption Certificate As At The Time Of Tender Opening Or Not Paid Emd Before Tender Opening Shall Be Summarily Rejected. Please See Attached Document ( Icf Tender Condition ) For The Same. 3 Secrity Deposit Sd There Shall Be No Exemption From Yes Yes Allowed Submission Of Security Deposit ( Sd ) For Any Tender Or ( Optional ) By Any Tenderer Subject Exemptions As Detailed In Para- 13 Of General Condition Of Tender. Please See Attach Document ( Icf Tender Conditions For The Same. 4 If You Are Not Mse Or A Consortia Of Mses Formed By Yes Yes Allowed Nsic, Please Indicate Percentage Of Sub Contract In ( Optional ) Execution Of This Tender That Will Be From Micro And Small Enterprises ( In Percent Of Order Value ) With Further Brake Up Of Mse Owned By Sc / St. ( Information Will Be Provided In % Terms With 6 Fields, Micro Owned By Sc, Micro Owned By St, Micro Owned By Others, Small Industry Owned By Sc, Small Industry Ownrd By St, Small Industry Owned By Others. 5 Earnest Money Deposit ( Emd ) : - Regarding Emd, Please Refer To Yes Yes Not Allowed Clause 6.0 Of Section I Instructions To Tenderer Of Icf Bid Document Ver.09 Attached To The Tender. All Bidders Shall Be Exempted From Submission Of Emd In All Tenders, Subject To Submission Of Bid Securing Declaration As Per The Following Para Of Tender Document, Except Those Who Disqualified From Such Exemption As Per Clause 6.2 Of Section-I Of Icf Bid Document Version 09 Have To Deposit Emd As Indicated In The Nit Header Of Tender Document. Offers Received Without Emd From The Disqualified Bidder Shall Be Summarily Rejected 6 Please Enter The Percentage Of Local Content In The Material Being Offered. Yes Yes Allowed Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. ( Mandatory ) The Definition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. Page 4 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 7 The Eligibility For A Bidder From A Country Which Shares A Land Border With Yes Yes Allowed India To Participate In The Tender Shall Be As Per Public Procurement Orders ( Mandatory ) Of Ministry Of Finance, Department Of Expenditure. Please Refer Clause 9.8 ( Sub Clause 9.8.1 To 9.8.8 ) Section-I Of Icf Bid Document Version 09. In This Regards I Certify That: I Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India: I Certify That This Bidder Is Not From Such A Country Or, If From Such A Country, Has Been Registered With The Competent Authority. I Hereby Certify That This Bidder Fulfills All Requirements In This Regard And Is Eligible To Be Considered. ( Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached ) . If Such Certificate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. 8 Goods & Services Tax ( Gst ) : Will Be Applicable As Per Clause 2.0 And All Yes Yes Not Allowed Sub Clauses Of Section-Ii Of Icf Bid Document Ver-09. 9 Bid Securing Declaration: I / We Hereby Understand And Accept That Yes Yes Allowed If I / We Withdraw Or Modify My / Our Bids During The Period Of Validity, Or If I / ( Mandatory ) We Are Awarded The Contract And On Being Called Upon To Submit The Performance Security / Security Deposit, Fail To Submit The Performance Security / Security Deposit Before The Deadline Defined In The Request For Bid Document / Notice Inviting Tender / Tender Document, We Shall Be Debarred From Exemption Of Submitting Bid Security / Earnest Money Deposit And Performance Security / Security Deposit For A Period Of 6 ( Six ) Months From The Date I / We Are Declared Disqualified From Exemption From Submission Of Emd / Sd, For All Tenders For Procurement Of Goods Issued By Any Unit Of Indian Railways Published During This Period. 10 Passing The Benefits Of Itc: I Hereby Confirm Following: We Hereby Declare Yes Yes Not Allowed That In Quoting The Above Price, We Have Taken Into Account The Full Effect Of Input Tax Credit Available Under Gst. We, Further Agree To Pass On Any Financial Gain / Benefit As May Become Available In Future In Respect Of All The Input Tax Credit On The Date Of Supply By Way Of Reduction In Price And Advise The Purchaser Accordingly. We Also Undertake That We Are Aware Of The Provisions Of Section 171 Of The Cgst Act And Consequences Thereof If We Fail To Comply With The Same. 11 Security Deposit: Please Refer Clause 13.0 Of Section-Ii Of Icf Bid Yes Yes Not Allowed Document Ver-09. 12 It Is Certified That Our Firm Has Not Been Suspended Or Banned By Indian Yes Yes Not Allowed Railways During Previous Three Years. 13 Public Procurement ( Preference To Make In India ) Policy Is Applicable As Yes Yes Not Allowed Per Clause 16 Of Section-I Of Icf Bid Document. The Procurement Shall Be Done In Accordance With The Extant Instruction Of Dpiit ( Department Of Promotion Of Industry And Internal Trade ) For Make In India Policy. 14 The Bidders Should Quote The Applicable Hsn Codes And It Is The Yes Yes Allowed Responsibility Of The Tenderer To Quote The Correct Hsn Code And Upload The ( Mandatory ) Document. 15 The Warranty Period Shall Be Two Years From The Date Of Issue Of Yes Yes Allowed Performance Certificate ( I.E., Jointcommissioning Note With Three Days ( Optional ) Prove Out Trial + 30 Days Performance Trial ) . During Warranty Period, Preventive Maintenance Shall Be Carried Out On Quarterly Basis, For This Separate Payment Will Not Be Given. The Details Of Preventive Maintenance To Be Provided During Warranty Period Shall Be Indicated By The Tenderer Giving Details Of Type Of Preventive Schedule, Periodicity On Items To Be Checked, Items To Be Replaced And Expected Plant Down Time. Preventive Maintenance Schedules Shall Be Conducted On Weekends As Far As Possible Or Any Other Day Through Mutual Agreement With Consignees. The Details Of Preventive Maintenance Services To Be Provided Under Warranty Shall Be Rovided By The Tenderer In The Following Format At 23.2 Of Technical Specification Attached. Page 5 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 16 It Is Certified That Our Firm Has Not Been De-Listed For Tendered Item By Indian Yes Yes Not Allowed Railways During Previous Three Years. 17 Please Submit The Details Of The Location At Which The Local Value Addition Is Yes Yes Not Allowed Being Made 18 Declaration On Cartel Formation The Definition Of Cartel Would Be As Per Yes Yes Allowed The Competition Act 2002 ( 12 Of 2003 ) . I / We Declare That I / We Are Not A ( Mandatory ) Part Of Cartel With Other Vendors And Have Offered Competitive Rates In The The Tenders. In The Event Of My / Our Offer Suspected To Be Of Collusive Bidding And Cartel Formation, I / We Understand That Purchaser Reserves The Right To Summarily Reject The Offer And To Ban My / Our Firm From Dealing With Railway. In The Event Of My / Our Offer Confirming To Any Aspect Of The Definition Of Cartel, I / We Understand That The Purchaser Reserves The Right To Refer The Matter To The Competition Commission Of India ( Cci ) Which Is A Statutory Body Constituted Under This Act, For Providing Necessary Relief To The Purchaser Who Represent Central Government Organization Serving The Public. In Addition, I / We Are Aware Of The Chapter Vi Of The Act, Which Deals With Penalties. I / We Understand That This Will Be In Addition To Other Rights And Remedies Available To The Railway Administration Under The Contract And The Law Of The Land. 19 Cartel Formation I / We Declare That I / We Are Not A Part Of Cartel With Yes Yes Allowed Other Vendors And Have Offered Competitive Rates In The Tenders. Please ( Mandatory ) Refer Clause 10.11.7 Of Section Ii Of Bid Document. 20 In Case Of Mse Firm Willing To Claim The Benefits Under Public Procurement Yes Yes Allowed Policy ( Preference To Mse ) Order 2012, The Firm Should Upload With Their ( Optional ) Offer, The Proof Of Their Being Mse Registered With Any Of The Agencies Mentioned In Clause 13.1 Of Section-I Of Icf Bid Document Failing Which Such Offers Will Not Be Liable For Consideration Of Benefits Detailed In Para 13.3 Of Section-I Of Icf Bid Document Tenderers Shall Upload Valid Documents As Per Mse Policy Showing That The Enterprise Is Owned By Scheduled Castes ( Sc ) / Scheduled Tribes ( St ) / Women Entrepreneurs To Claim The Benefit Under This Sub-Classification. For This Purpose Tenderers To Submit Details Of Share Holding Pattern & Controlling Stakes With Scheduled Castes ( Sc ) / Scheduled Tribes ( St ) / Women Entrepreneurs Duly Certified By Ca, Failing Which It Will Be Presumed That They Have No Claim Under This Sub-Classification. 21 1.Traders / Distributors / Sole Agent / Works Contract Are Not Exempted From Yes Yes Allowed Payment Of Emd As They Are Excluded From The Purview Of The Mse Policy ( Mandatory ) . 2. In Reference To Conditions No.6.1 ( Vi ) Of Section I Of Icf Bid Document, The Exemption Of Emd Is Applicable Only To The Vendors Having Current And Valid Registration With Pcmm Of Any Zonal Railways / Production Unit For Trade Groups 6579. Firm Should Submit Valid Registration Certificate For Proof. 22 Firm To Quote Strictly As Per Specification Attached. Please Go Through The Yes Yes Allowed Other Conditions Mentioned In The Tender With Regard To Arrangements ( Optional ) Before Supply And Erection. 23 The Tenderers Shall Indicate The Details Of Their Jurisdictional Assessing Yes Yes Allowed Officers ( Designation, Address & Email Id ) . ( Optional ) 24 Make In India: As Per Public Procurement ( Preference To Make In India ) Yes Yes Allowed Order 2017, As Amended, Only Class-I And Class-Ii Local Suppliers Are ( Mandatory ) Eligible To Participate In The Tender. Vendors Who Do Not Qualify To Be Class-I Or Class-Ii Local Suppliers Should Not Quote In The Tender As Their Offers Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class-I Or Class-Ii Local Suppliers For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. Page 6 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 25 Scope Of Supply : 1. The Scope Of Supply Shall Include Design, Supply, Yes Yes Allowed Installation, Testing, Commissioning And Proving Out, Warranty Of ( Mandatory ) Electromagnetic Crack Detector Equipment On Turnkey Basis, Required For Crack Detection Of Various Types Of Axles As Per En 13261 As Listed In Annexure -E. The Supply Shall Include All The Concomitant Accessories / Equipments As Detailed In The Specification And Other Concomitant Accessories / Equipment, Which The Manufacturer Considers Essential To Make The Machine Fully Operational, When Installed And Commissioned. It Shall Also Include Installation And Commissioning Of Related Equipment, Training Of Personnel In Operation And Maintenance Of Machine As Per Clause 10.1 And Supply Of Technical Documentation As Per Clause 11 Of Technical Literature. 2. The Scope Of Supply Includes Installation, Commissioning Of Equipment And Proving Out At The Cost Of The Supplier At Icf And Training Of Railway Staff For Operating, Maintenance For Using The Equipment. 26 Please Enter The Percentage Of Local Content In The Material Being Offered. No Yes Not Allowed Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Definition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Please Download And Peruse The Tender Document Conditions Applicable For No No Not Allowed Tenders Which Is Attached With The Tender. 2 Icf Bid Document Version 9 Dated 01.11.22 Is Applicable For This Tender. No No Not Allowed 3 Material To Be Supplied At Shell Depot No No Not Allowed Other Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tpi Agency, As Per The Clause 16.0 Of Technical Specification Attached. No No Not Allowed 2 Tenderer To Indicate The Address And Place Of Inspection For Tpi Inspection No No Not Allowed 3 The Tenderer Shall Have Capacity To Undertake Comprehensive Annual Yes Yes Allowed Maintenance Contract. ( Optional ) 4 Suitable Warranty Clauses, Bank Guarantee Clauses, Preventive Yes Yes Allowed Maintenance During Warranty, Penalty For Delay In Commissioning, Delay ( Optional ) During Maintenance Other Than The Above Mentioned Shall Be Applicable As Per The Guidelines Issued By General Conditions Of Contract ( Stores ) For M&P Items In Addition To The Warranty Clauses Mentioned Above Whichever Is Stricter. Special Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderers May Note That The Ireps Software Is Contiunously Being No No Not Allowed Upgraded And The Forms May Be Subject To Changes. Tenderers Are Advised To Keep Themselves Updated With The Latest Changes, By Referring To The Latest Versions Of User Manuals Available On The Website, And By Taking Notes Of The Messages Sent By Our Ireps Adminstrator From Time To Time. Tenderers Should Also Make Themselves Fully Acquainted With All Available Templates / Forms Before They Submit Their Offer. No Claim Shall Be Entertained From A Tenderer, On Account Of Non Familarity With Any Of The Templates And Form Available On The Ireps Websites. Page 7 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 2 A ) No Manual Submission Of Documents Is Permitted. Tenderers Shall No No Not Allowed Upload All The Documents In Ireps Portal Only. 3 Tenederers Can Upload Individual File Having Capacity Of 3.5 To 3.7 Mb As No No Not Allowed Attached Document However There Is No Llimitation On The Numbers Of Files Which Can Attached. Tenderers Are Advised To Upload The Documents Well In Advance To Avoid Last Minutes Rush And Complication. All Documents Which Are Submitted Should Be In A4 Size To Facilitate Printing. 4 Tenderers To Refer The List Of Mandatory And Optional Certificates To Be No No Not Allowed Submitted Along With The Offer As Per Icf Bid Documents. 5 Please Check Ireps Website Before Submitting Offer, Any Corrigendum To No No Not Allowed The Tender Has Been Issued Or Not.Please Check Ireps Website Frequently For Corrigendum And Ensure Submission Of Offer As Per Corrigendum Issued By Icf 6 The Minimum Local Content For The Local Supplier Of The Tendered Item To Be No No Not Allowed Categorised As Class-I Local Supplier Shall Be 50% And Class-Ii Supplier Is 20% 7 Offers From Different Tenderers Submitted From The Same Ip Address In A No No Not Allowed Tender Shall Be Treated As Suspected Cartel And All Such Offers Received From The Same Ip Address Will Be Summarily Rejected. However Offers Resulting In Same Ip Address Due To Administrative Reason Like Technical / Networking Issue At Cris Server Shall Not Be Treated As Suspected Cartel And The Decision Of The Railway Administration Will Be Binding On All Tenderers 8 Firm To Submit The Clause Wise Compliance / Deviation Description And Past No No Not Allowed Performance Detail As Per The Annexure -A Attached. Technical-Compliances S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderers Are Advised To Go Through All The Clauses Of This Document, Icf Yes Yes Allowed Bid Document And Other Documents Attached And Submit Necessary ( Optional ) Documents, Certificates, Attachments, Etc. Along With The Offer To Establish Their Credentials In Support Of Their Claim. If Required, Clarifications Will Be Sought Only On The Documents Submitted And No Additional Documents Shall Be Entertained Post Tender Opening. 2 Firm To Submit The Clause Wise Compliance For Yes Yes Allowed Technical Specification / Deviation Statement And Past ( Mandatory ) Performance Details As Per The Annexure - A Attached. 3 Installation, Commissioning Of Equipment And Proving Out At The Cost Of The Yes Yes Allowed Supplier At Icf And Training Of Railway Staff For Operating, Maintenance For ( Optional ) Using The Equipment. 4 Bidder Shall Train The Minimum Nominated 5 Railway Staff For Operating, Yes Yes Allowed Maintenance For Using The Equipment. ( Optional ) 5 Prove Out At Consignees Works : The Firm Shall Be Required To Demonstrate Yes Yes Allowed The Machine Capability & Prove Out The Various Performance Tests And ( Mandatory ) Claimed Productivity Requirement / Cycle Time On 20 Nos. Of Axles As Listed At Annexure-E At Consignees End For The Period Of Three Days Comprising 8 Hour Shift During Commissioning Of Machine. Undertakings S.No. Description Confirmation Remarks Documents Required Allowed Uploading Page 8 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 1 I / We Also Confirm That If Any Information And Document Submitted Is Found No No Not Allowed To Be False / Incorrect At Any Time, Icf May Cancel My / Our Bid And Action As Deemed Fit May Be Taken Against Me / Us, Including Termination Of The Contract, Forfeiture Of Earnest Money, Security Deposit And Banning / Delisting / Suspension Of Our Firm And All Partners Of The Firm. 2 I / We Also Confirm That Rates And Other Financial Terms Quoted In Relevant No No Not Allowed Columns Of Financial Bid Will Only Be Applicable For Acceptance. Such Terms Quoted Anywhere Else Should Not Be Considered For Inter-Se Evaluation And Should Be Ignored. 3 I / We Have Gone Through The All Clauses Of This Tender Document And Other No No Not Allowed Documents Such As Icf Bid Document Version 05, Special Condition Of Tenders, Checklist And Technical Specification Uploaded Along With This Tender. It Is Understood That The Tenderer Submitting Their Offer Is Fully Aware Of All The Clauses Of The Above Said Documents And Undertake To Abide By Submitting This Offer. 6. Documents Attached With Tender S.No. Document Name Document Description 1 4235187.Pdf Technical Specification 2 4305772.Pdf Tpi Condition 3 4305380.Pdf Bid Document Ver-09, Dated 01 / 11 / 2022 7. Responsiveness S.No. Description Validity Of Offer: No Deviation From The Offer Validity Period Stipulated In The Nit Header Of This Tender Document Is 1 Permitted. For Additional Conditions Please Refer Clause 12.0 Of Section -I Of Icf Bid Document Version 09. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers ( Designation, Address & Email Id ) . In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy ( Make In India ) Order 2017, Dated 15 / 06 / 2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015 / Rs ( G ) / 779 / 5 Dated 03 / 08 / 2017 And 27 / 12 / 2017 And Amendments / Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm / Dc ( V.N. Satheesan ) , Charges For Comprehensive Amc For Year 2, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 4 8347N004 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 3, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 3 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers Page 1 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 5 8347N005 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 4, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 4 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 6 8347N006 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 5, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 5 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery / Completion Rate Of Supply For All Items Completion : Within 220 Days As Per The Delivery Chart At Class 7 And 8 At Technical Specification Attached. Payment Terms S.No Description Payment Terms 1 80% Payment Will Be Released After Successful Commissioning And Proving Out Of The Machine. After Successful Performance Test For One Month Remaining 20% Payment Will Be Released Subject To Submission Of Bank Guarantee / Warranty Guarantee Bond For An Amount Of 10% Of Contract Value Towards Warranty Performance / Warranty Security Valid Beyond Six Month Period Of Warranty. Penalty May Be Levied For Delay In Commissioning Of The Equipment By The Bidder As Per Relevant Gcc Conditions. The Bank Guarantee / Warranty Guarantee Bond Will Be Returned To The Supplier After Warranty Period By Detecting Any Penalty, If Levied. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State / Central Governments In Respect Of The Items Stipulated In The Contract ( And Not The Raw Materials Thereof ) , Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax / Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His Offer The Rate Of Tax / Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier / Contractor. Railway Standard Fall Clause S.No Description 1 Not To Be Included Standard Governing Conditions Page 2 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 S.No Description 1 Applicable As Detailed In This Tender Document And In Icf Bid Document, Special Conditions / Annexures Attached With The Tender Document ( If Any ) , And Conditions Mentioned In Technical Specification / Str / Drawings Uploaded Along With This Tender. For Contracts, Irs Conditions Of Contract Wherever Specifically Not Modified In The Above Said Documents Shall Apply. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderer Shall Be A Reputed Manufacturer In The Subject Field. Yes Yes Allowed ( Mandatory ) 2 I ) Tenderer Should Have Supplied At Least 01 No. Of Emcd Machine For Yes Yes Allowed Testing Railway Axle To Govt. / Public Sector / Mncs / Reputed Private ( Mandatory ) Companies. Or Ii ) Tenderer Should Have Supplied At Least 05 Nos. Of Similar Capacity Machines With Minimum 10000Amps In The Past Five Years To Railways And Other Govt. Sectors / Public Sector / Mncs / Reputed Private Companies. Proof For Supply ( Purchase Order, Commissioning And Performance Certificate To Be Attached As Per Annexure A Clause 2 ) . 5. Compliance Conditions Check List S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 In Case Of Indigenous Bidders, Whether You Are Large Scale Industry Or No No Not Allowed Consortia Of Mses Formed By Nsic, If Yes, Have You Indicated Quantum Of Sub Contracts Given To Micro And Small Enterprises ( In Percent Of Order Value ) ? 2 Have You Gone Through The Eligibility Criteria And Submitted All The No No Not Allowed Documents Mentioned Therein? 3 Have You Submitted The Emd Or Bid Securing Declaration As Per Clause 6.0 No No Not Allowed Of Section-I Of Instructions To Tenderers Of Icf Bid Document Version 09. 4 Have You Furnished Financial Capacity As Per Clause 9.2.1 ( Iii ) Of Section-I Of No No Not Allowed Instructions To Tenderers Of Icf Bid Document Version 09. 5 Have You Confirmed For Compliance Of Public Procurement Orders Of No No Not Allowed Department Of Expenditure Regarding Countries Sharing Land Border With India? 6 Have You Submitted The Details Of Location ( S ) At Which Local Value Addition No No Not Allowed Is Made / Proposed? 7 In Case Of Non-Local / Class-Ii Suppliers, Have You Submitted Road Map For No No Not Allowed Setting Up Manufacturing Facilities For Tendered Item Along With The Offer? ( This Is Applicable Only For Items Which Are Not Restricted To Class-I Local Suppliers ) . 8 Have You Submitted Self-Declaration With Respect To Non Debarment Under No No Not Allowed Any Provisions Of Dpiit Rules? 9 Have You Submitted Translated Copy Into English, For All Documents In No No Not Allowed Language Other Than English And All Such Documents Should Be Signed By The Authorised Translator And Notarized In India? 10 Have You Submitted Declaration For Passing On The Input Tax Credit As Per No No Not Allowed Para 2.8 And 2.9 Of Section-Ii Of Icf Bid Document Version 09. 11 Have You Submitted Authenticated Copy Of The Document Authorizing The No No Not Allowed Signatory To Submit Offer And Commit On Behalf Of Tenderers? 12 Have You Furnished The Statement Of Deviations ( Preferably Nil ) ? No No Not Allowed Page 3 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 13 Have You Furnished The Statement Of Equipment & Quality Control? No No Not Allowed 14 Have You Kept Your Offer Valid For The Validity Period As Mentioned In Nit No No Not Allowed Header? Commercial-Compliance S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Firm Should Furnish Gst No. And Hsn Code No. In Their Offer. Yes Yes Allowed ( Mandatory ) 2 The Tenderers Must Submit Emd As Detailed Under Yes Yes Allowed Clause -6 Of Instructions To Tenderers. Tenderers ( Optional ) Seeking Exemption From Payment Of Emd Must Upload The Requisite Documentary Evidence In Support Of Their Claim For Exemption From Payment Of Emd Along With The Offer. Any Offer Either Not Accompanied With A Vaild Exemption Certificate As At The Time Of Tender Opening Or Not Paid Emd Before Tender Opening Shall Be Summarily Rejected. Please See Attached Document ( Icf Tender Condition ) For The Same. 3 Secrity Deposit Sd There Shall Be No Exemption From Yes Yes Allowed Submission Of Security Deposit ( Sd ) For Any Tender Or ( Optional ) By Any Tenderer Subject Exemptions As Detailed In Para- 13 Of General Condition Of Tender. Please See Attach Document ( Icf Tender Conditions For The Same. 4 If You Are Not Mse Or A Consortia Of Mses Formed By Yes Yes Allowed Nsic, Please Indicate Percentage Of Sub Contract In ( Optional ) Execution Of This Tender That Will Be From Micro And Small Enterprises ( In Percent Of Order Value ) With Further Brake Up Of Mse Owned By Sc / St. ( Information Will Be Provided In % Terms With 6 Fields, Micro Owned By Sc, Micro Owned By St, Micro Owned By Others, Small Industry Owned By Sc, Small Industry Ownrd By St, Small Industry Owned By Others. 5 Earnest Money Deposit ( Emd ) : - Regarding Emd, Please Refer To Yes Yes Not Allowed Clause 6.0 Of Section I Instructions To Tenderer Of Icf Bid Document Ver.09 Attached To The Tender. All Bidders Shall Be Exempted From Submission Of Emd In All Tenders, Subject To Submission Of Bid Securing Declaration As Per The Following Para Of Tender Document, Except Those Who Disqualified From Such Exemption As Per Clause 6.2 Of Section-I Of Icf Bid Document Version 09 Have To Deposit Emd As Indicated In The Nit Header Of Tender Document. Offers Received Without Emd From The Disqualified Bidder Shall Be Summarily Rejected 6 Please Enter The Percentage Of Local Content In The Material Being Offered. Yes Yes Allowed Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. ( Mandatory ) The Definition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. Page 4 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 7 The Eligibility For A Bidder From A Country Which Shares A Land Border With Yes Yes Allowed India To Participate In The Tender Shall Be As Per Public Procurement Orders ( Mandatory ) Of Ministry Of Finance, Department Of Expenditure. Please Refer Clause 9.8 ( Sub Clause 9.8.1 To 9.8.8 ) Section-I Of Icf Bid Document Version 09. In This Regards I Certify That: I Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India: I Certify That This Bidder Is Not From Such A Country Or, If From Such A Country, Has Been Registered With The Competent Authority. I Hereby Certify That This Bidder Fulfills All Requirements In This Regard And Is Eligible To Be Considered. ( Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached ) . If Such Certificate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. 8 Goods & Services Tax ( Gst ) : Will Be Applicable As Per Clause 2.0 And All Yes Yes Not Allowed Sub Clauses Of Section-Ii Of Icf Bid Document Ver-09. 9 Bid Securing Declaration: I / We Hereby Understand And Accept That Yes Yes Allowed If I / We Withdraw Or Modify My / Our Bids During The Period Of Validity, Or If I / ( Mandatory ) We Are Awarded The Contract And On Being Called Upon To Submit The Performance Security / Security Deposit, Fail To Submit The Performance Security / Security Deposit Before The Deadline Defined In The Request For Bid Document / Notice Inviting Tender / Tender Document, We Shall Be Debarred From Exemption Of Submitting Bid Security / Earnest Money Deposit And Performance Security / Security Deposit For A Period Of 6 ( Six ) Months From The Date I / We Are Declared Disqualified From Exemption From Submission Of Emd / Sd, For All Tenders For Procurement Of Goods Issued By Any Unit Of Indian Railways Published During This Period. 10 Passing The Benefits Of Itc: I Hereby Confirm Following: We Hereby Declare Yes Yes Not Allowed That In Quoting The Above Price, We Have Taken Into Account The Full Effect Of Input Tax Credit Available Under Gst. We, Further Agree To Pass On Any Financial Gain / Benefit As May Become Available In Future In Respect Of All The Input Tax Credit On The Date Of Supply By Way Of Reduction In Price And Advise The Purchaser Accordingly. We Also Undertake That We Are Aware Of The Provisions Of Section 171 Of The Cgst Act And Consequences Thereof If We Fail To Comply With The Same. 11 Security Deposit: Please Refer Clause 13.0 Of Section-Ii Of Icf Bid Yes Yes Not Allowed Document Ver-09. 12 It Is Certified That Our Firm Has Not Been Suspended Or Banned By Indian Yes Yes Not Allowed Railways During Previous Three Years. 13 Public Procurement ( Preference To Make In India ) Policy Is Applicable As Yes Yes Not Allowed Per Clause 16 Of Section-I Of Icf Bid Document. The Procurement Shall Be Done In Accordance With The Extant Instruction Of Dpiit ( Department Of Promotion Of Industry And Internal Trade ) For Make In India Policy. 14 The Bidders Should Quote The Applicable Hsn Codes And It Is The Yes Yes Allowed Responsibility Of The Tenderer To Quote The Correct Hsn Code And Upload The ( Mandatory ) Document. 15 The Warranty Period Shall Be Two Years From The Date Of Issue Of Yes Yes Allowed Performance Certificate ( I.E., Jointcommissioning Note With Three Days ( Optional ) Prove Out Trial + 30 Days Performance Trial ) . During Warranty Period, Preventive Maintenance Shall Be Carried Out On Quarterly Basis, For This Separate Payment Will Not Be Given. The Details Of Preventive Maintenance To Be Provided During Warranty Period Shall Be Indicated By The Tenderer Giving Details Of Type Of Preventive Schedule, Periodicity On Items To Be Checked, Items To Be Replaced And Expected Plant Down Time. Preventive Maintenance Schedules Shall Be Conducted On Weekends As Far As Possible Or Any Other Day Through Mutual Agreement With Consignees. The Details Of Preventive Maintenance Services To Be Provided Under Warranty Shall Be Rovided By The Tenderer In The Following Format At 23.2 Of Technical Specification Attached. Page 5 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 16 It Is Certified That Our Firm Has Not Been De-Listed For Tendered Item By Indian Yes Yes Not Allowed Railways During Previous Three Years. 17 Please Submit The Details Of The Location At Which The Local Value Addition Is Yes Yes Not Allowed Being Made 18 Declaration On Cartel Formation The Definition Of Cartel Would Be As Per Yes Yes Allowed The Competition Act 2002 ( 12 Of 2003 ) . I / We Declare That I / We Are Not A ( Mandatory ) Part Of Cartel With Other Vendors And Have Offered Competitive Rates In The The Tenders. In The Event Of My / Our Offer Suspected To Be Of Collusive Bidding And Cartel Formation, I / We Understand That Purchaser Reserves The Right To Summarily Reject The Offer And To Ban My / Our Firm From Dealing With Railway. In The Event Of My / Our Offer Confirming To Any Aspect Of The Definition Of Cartel, I / We Understand That The Purchaser Reserves The Right To Refer The Matter To The Competition Commission Of India ( Cci ) Which Is A Statutory Body Constituted Under This Act, For Providing Necessary Relief To The Purchaser Who Represent Central Government Organization Serving The Public. In Addition, I / We Are Aware Of The Chapter Vi Of The Act, Which Deals With Penalties. I / We Understand That This Will Be In Addition To Other Rights And Remedies Available To The Railway Administration Under The Contract And The Law Of The Land. 19 Cartel Formation I / We Declare That I / We Are Not A Part Of Cartel With Yes Yes Allowed Other Vendors And Have Offered Competitive Rates In The Tenders. Please ( Mandatory ) Refer Clause 10.11.7 Of Section Ii Of Bid Document. 20 In Case Of Mse Firm Willing To Claim The Benefits Under Public Procurement Yes Yes Allowed Policy ( Preference To Mse ) Order 2012, The Firm Should Upload With Their ( Optional ) Offer, The Proof Of Their Being Mse Registered With Any Of The Agencies Mentioned In Clause 13.1 Of Section-I Of Icf Bid Document Failing Which Such Offers Will Not Be Liable For Consideration Of Benefits Detailed In Para 13.3 Of Section-I Of Icf Bid Document Tenderers Shall Upload Valid Documents As Per Mse Policy Showing That The Enterprise Is Owned By Scheduled Castes ( Sc ) / Scheduled Tribes ( St ) / Women Entrepreneurs To Claim The Benefit Under This Sub-Classification. For This Purpose Tenderers To Submit Details Of Share Holding Pattern & Controlling Stakes With Scheduled Castes ( Sc ) / Scheduled Tribes ( St ) / Women Entrepreneurs Duly Certified By Ca, Failing Which It Will Be Presumed That They Have No Claim Under This Sub-Classification. 21 1.Traders / Distributors / Sole Agent / Works Contract Are Not Exempted From Yes Yes Allowed Payment Of Emd As They Are Excluded From The Purview Of The Mse Policy ( Mandatory ) . 2. In Reference To Conditions No.6.1 ( Vi ) Of Section I Of Icf Bid Document, The Exemption Of Emd Is Applicable Only To The Vendors Having Current And Valid Registration With Pcmm Of Any Zonal Railways / Production Unit For Trade Groups 6579. Firm Should Submit Valid Registration Certificate For Proof. 22 Firm To Quote Strictly As Per Specification Attached. Please Go Through The Yes Yes Allowed Other Conditions Mentioned In The Tender With Regard To Arrangements ( Optional ) Before Supply And Erection. 23 The Tenderers Shall Indicate The Details Of Their Jurisdictional Assessing Yes Yes Allowed Officers ( Designation, Address & Email Id ) . ( Optional ) 24 Make In India: As Per Public Procurement ( Preference To Make In India ) Yes Yes Allowed Order 2017, As Amended, Only Class-I And Class-Ii Local Suppliers Are ( Mandatory ) Eligible To Participate In The Tender. Vendors Who Do Not Qualify To Be Class-I Or Class-Ii Local Suppliers Should Not Quote In The Tender As Their Offers Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Class-I Or Class-Ii Local Suppliers For The Tendered Item Participates In The Tender It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. Page 6 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 25 Scope Of Supply : 1. The Scope Of Supply Shall Include Design, Supply, Yes Yes Allowed Installation, Testing, Commissioning And Proving Out, Warranty Of ( Mandatory ) Electromagnetic Crack Detector Equipment On Turnkey Basis, Required For Crack Detection Of Various Types Of Axles As Per En 13261 As Listed In Annexure -E. The Supply Shall Include All The Concomitant Accessories / Equipments As Detailed In The Specification And Other Concomitant Accessories / Equipment, Which The Manufacturer Considers Essential To Make The Machine Fully Operational, When Installed And Commissioned. It Shall Also Include Installation And Commissioning Of Related Equipment, Training Of Personnel In Operation And Maintenance Of Machine As Per Clause 10.1 And Supply Of Technical Documentation As Per Clause 11 Of Technical Literature. 2. The Scope Of Supply Includes Installation, Commissioning Of Equipment And Proving Out At The Cost Of The Supplier At Icf And Training Of Railway Staff For Operating, Maintenance For Using The Equipment. 26 Please Enter The Percentage Of Local Content In The Material Being Offered. No Yes Not Allowed Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Definition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Please Download And Peruse The Tender Document Conditions Applicable For No No Not Allowed Tenders Which Is Attached With The Tender. 2 Icf Bid Document Version 9 Dated 01.11.22 Is Applicable For This Tender. No No Not Allowed 3 Material To Be Supplied At Shell Depot No No Not Allowed Other Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tpi Agency, As Per The Clause 16.0 Of Technical Specification Attached. No No Not Allowed 2 Tenderer To Indicate The Address And Place Of Inspection For Tpi Inspection No No Not Allowed 3 The Tenderer Shall Have Capacity To Undertake Comprehensive Annual Yes Yes Allowed Maintenance Contract. ( Optional ) 4 Suitable Warranty Clauses, Bank Guarantee Clauses, Preventive Yes Yes Allowed Maintenance During Warranty, Penalty For Delay In Commissioning, Delay ( Optional ) During Maintenance Other Than The Above Mentioned Shall Be Applicable As Per The Guidelines Issued By General Conditions Of Contract ( Stores ) For M&P Items In Addition To The Warranty Clauses Mentioned Above Whichever Is Stricter. Special Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderers May Note That The Ireps Software Is Contiunously Being No No Not Allowed Upgraded And The Forms May Be Subject To Changes. Tenderers Are Advised To Keep Themselves Updated With The Latest Changes, By Referring To The Latest Versions Of User Manuals Available On The Website, And By Taking Notes Of The Messages Sent By Our Ireps Adminstrator From Time To Time. Tenderers Should Also Make Themselves Fully Acquainted With All Available Templates / Forms Before They Submit Their Offer. No Claim Shall Be Entertained From A Tenderer, On Account Of Non Familarity With Any Of The Templates And Form Available On The Ireps Websites. Page 7 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 2 A ) No Manual Submission Of Documents Is Permitted. Tenderers Shall No No Not Allowed Upload All The Documents In Ireps Portal Only. 3 Tenederers Can Upload Individual File Having Capacity Of 3.5 To 3.7 Mb As No No Not Allowed Attached Document However There Is No Llimitation On The Numbers Of Files Which Can Attached. Tenderers Are Advised To Upload The Documents Well In Advance To Avoid Last Minutes Rush And Complication. All Documents Which Are Submitted Should Be In A4 Size To Facilitate Printing. 4 Tenderers To Refer The List Of Mandatory And Optional Certificates To Be No No Not Allowed Submitted Along With The Offer As Per Icf Bid Documents. 5 Please Check Ireps Website Before Submitting Offer, Any Corrigendum To No No Not Allowed The Tender Has Been Issued Or Not.Please Check Ireps Website Frequently For Corrigendum And Ensure Submission Of Offer As Per Corrigendum Issued By Icf 6 The Minimum Local Content For The Local Supplier Of The Tendered Item To Be No No Not Allowed Categorised As Class-I Local Supplier Shall Be 50% And Class-Ii Supplier Is 20% 7 Offers From Different Tenderers Submitted From The Same Ip Address In A No No Not Allowed Tender Shall Be Treated As Suspected Cartel And All Such Offers Received From The Same Ip Address Will Be Summarily Rejected. However Offers Resulting In Same Ip Address Due To Administrative Reason Like Technical / Networking Issue At Cris Server Shall Not Be Treated As Suspected Cartel And The Decision Of The Railway Administration Will Be Binding On All Tenderers 8 Firm To Submit The Clause Wise Compliance / Deviation Description And Past No No Not Allowed Performance Detail As Per The Annexure -A Attached. Technical-Compliances S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Tenderers Are Advised To Go Through All The Clauses Of This Document, Icf Yes Yes Allowed Bid Document And Other Documents Attached And Submit Necessary ( Optional ) Documents, Certificates, Attachments, Etc. Along With The Offer To Establish Their Credentials In Support Of Their Claim. If Required, Clarifications Will Be Sought Only On The Documents Submitted And No Additional Documents Shall Be Entertained Post Tender Opening. 2 Firm To Submit The Clause Wise Compliance For Yes Yes Allowed Technical Specification / Deviation Statement And Past ( Mandatory ) Performance Details As Per The Annexure - A Attached. 3 Installation, Commissioning Of Equipment And Proving Out At The Cost Of The Yes Yes Allowed Supplier At Icf And Training Of Railway Staff For Operating, Maintenance For ( Optional ) Using The Equipment. 4 Bidder Shall Train The Minimum Nominated 5 Railway Staff For Operating, Yes Yes Allowed Maintenance For Using The Equipment. ( Optional ) 5 Prove Out At Consignees Works : The Firm Shall Be Required To Demonstrate Yes Yes Allowed The Machine Capability & Prove Out The Various Performance Tests And ( Mandatory ) Claimed Productivity Requirement / Cycle Time On 20 Nos. Of Axles As Listed At Annexure-E At Consignees End For The Period Of Three Days Comprising 8 Hour Shift During Commissioning Of Machine. Undertakings S.No. Description Confirmation Remarks Documents Required Allowed Uploading Page 8 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf Tender Document Tender No 01235153 Closing Date / Time 15 / 05 / 2023 14:15 1 I / We Also Confirm That If Any Information And Document Submitted Is Found No No Not Allowed To Be False / Incorrect At Any Time, Icf May Cancel My / Our Bid And Action As Deemed Fit May Be Taken Against Me / Us, Including Termination Of The Contract, Forfeiture Of Earnest Money, Security Deposit And Banning / Delisting / Suspension Of Our Firm And All Partners Of The Firm. 2 I / We Also Confirm That Rates And Other Financial Terms Quoted In Relevant No No Not Allowed Columns Of Financial Bid Will Only Be Applicable For Acceptance. Such Terms Quoted Anywhere Else Should Not Be Considered For Inter-Se Evaluation And Should Be Ignored. 3 I / We Have Gone Through The All Clauses Of This Tender Document And Other No No Not Allowed Documents Such As Icf Bid Document Version 05, Special Condition Of Tenders, Checklist And Technical Specification Uploaded Along With This Tender. It Is Understood That The Tenderer Submitting Their Offer Is Fully Aware Of All The Clauses Of The Above Said Documents And Undertake To Abide By Submitting This Offer. 6. Documents Attached With Tender S.No. Document Name Document Description 1 4235187.Pdf Technical Specification 2 4305772.Pdf Tpi Condition 3 4305380.Pdf Bid Document Ver-09, Dated 01 / 11 / 2022 7. Responsiveness S.No. Description Validity Of Offer: No Deviation From The Offer Validity Period Stipulated In The Nit Header Of This Tender Document Is 1 Permitted. For Additional Conditions Please Refer Clause 12.0 Of Section -I Of Icf Bid Document Version 09. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers ( Designation, Address & Email Id ) . In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy ( Make In India ) Order 2017, Dated 15 / 06 / 2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015 / Rs ( G ) / 779 / 5 Dated 03 / 08 / 2017 And 27 / 12 / 2017 And Amendments / Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm / Dc ( V.N. Satheesan ) , Charges For Comprehensive Amc For Year 3, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 3 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers Page 1 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf , Charges For Comprehensive Amc For Year 4, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 4 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 6 8347N006 Amc ( Y ) Non Stock --- Yes Consignee Inr Charges For Comprehensive Amc For Year 5, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 5 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery / Completion Rate Of Supply For All Items Completion : Within 220 Days As Per The Delivery Chart At Class 7 And 8 At Technical Specification Attached. Payment Terms S.No Description Payment Terms 1 80% Payment Will Be Released After Successful Commissioning And Proving Out Of The Machine. After Successful Performance Test For One Month Remaining 20% Payment Will Be Released Subject To Submission Of Bank Guarantee / Warranty Guarantee Bond For An Amount Of 10% Of Contract Value Towards Warranty Performance / Warranty Security Valid Beyond Six Month Period Of Warranty. Penalty May Be Levied For Delay In Commissioning Of The Equipment By The Bidder As Per Relevant Gcc Conditions. The Bank Guarantee / Warranty Guarantee Bond Will Be Returned To The Supplier After Warranty Period By Detecting Any Penalty, If Levied. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State / Central Governments In Respect Of The Items Stipulated In The Contract ( And Not The Raw Materials Thereof ) , Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax / Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His Offer The Rate Of Tax / Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassification By The Supplier / Contractor. Railway Standard Fall Clause S.No Description 1 Not To Be Included Standard Governing Conditions Page 2 Of 9 Run Date / Time: 21 / 04 / 2023 11:01:25Stores / Shell / Icf , Charges For Comprehensive Amc For Year 5, After Expiry Of Warranty Period Of 30 Months From The Date Of Supply Of The Equipment Warranty Period: 5 Years, Amc Period: 5 Years, Rate Of Discounting: 0 % At ( Location ) Cmt / Shell , Icf Tamil Nadu 1.00 Numbers
Contract Date: May 07, 2026 Contract Value : 35.16 Lakh
Government Departments No of Bidders 1
9.
Home Affairs #10977452 AOC
Supply Of Stationaryand Forms ( Part-I ) , Miscellaneous Articles ( Part-Ii ) For Sap 4Th Battalion, Kasba, Raiganj, Uttar Dinajpur 2023-24. Sl. No. Item Description 1 Office Stationary Articles ( Part-I ) 2 Pen ( Red ) 3 Pen ( Blue ) 4 Pen ( Black ) 5 Pen ( Green ) 6 Refill ( Red ) 7 Refill ( Blue ) 8 Refill ( Black ) 9 Refill ( Green ) 10 Ball Pen ( Red ) 11 Ball Pen ( Blue ) 12 Ball Pen ( Black ) 13 Blank C.D. & D.V.D. Plastic Cover 14 Bodkin With Eye As Per Sample 15 Bound Register Un-Ruled 150 Sheet As Per Sample 16 Bound Register Un-Ruled 300 Sheet As Per Sample 17 Bound Register Un-Ruled 400 Sheet As Per Sample 18 Bound Register No. 08 Un-Ruled 120 Sheet Conquest Pages 19 Bound Register No. 08 Ruled 120 Sheet Conquest Pages 20 Bound Register No. 10 Un- Ruled 150 Sheet Conquest Pages 21 Bound Register No. 10 Ruled 150 Sheet Conquest Pages 22 Bound Register No. 04 Un-Ruled Conquest Pages 23 Bound Register No. 04 Ruled Conquest Pages 24 Bound Register No. 12 Un- Ruled 200 Sheet Conquest Pages 25 Calculator ( 12 Digit ) Big Size 112 Steps, Check & Correct Best Quality 26 Collin Big Size 27 Compute Paper 80 Column ( With Carbon ) As Per Sample 28 Compute Paper 80 Column ( Without Carbon ) As Per Sample 29 Correction Pen 30 Chalk Pencil 31 Channel File 32 Clip Board File ( Plastic ) 33 Borosil With Lid 34 Duplicating Paper ( Size- 21 X 33 Cm ) 500 Sheet 35 Duster Cloth ( Size- 54 X 30 Cm ) 36 Duster Cloth ( Big Size ) 37 Duster Cloth ( Regular ) 38 Duster Wood ( Best Quality ) 39 Eraser 40 Folio Bag For Office Use ( Best Quality ) 41 Fax Roll 42 Gum 300 Ml. Bottle 43 Gum 700 Ml. Bottle 44 Gum Tube 50 Ml 45 Gum Tube 20 Ml 46 12 Laser Jet Printer Toner Cartridge 1020 47 High Light Pen 48 James Clip 49 Key Bag Medium Best Quality 50 Knife Big Size 51 Marker Pen With Cdm 52 Marker Pen Permanent 53 Cd Blank ( R ) 54 Dvd Blank ( R ) 55 Dvd Blank ( R / W ) 56 Note Pad ( Itc ) 57 Paper Weight Squire Type Best Quality 58 Pendrive ( 16 Gb ) 59 Pendrive ( 32 Gb ) 60 Pendrive ( 08 Gb ) 61 Pen Stand Best Quality Medium 62 Pen Stand Best Quality Big 63 Pencil Carbon ( Dfc Size ) 64 Pencil Carbon ( Sf Size ) 65 Pilot Pen V5 / V7 ( Red ) 66 Pilot Pen V5 / V7 ( Blue ) 67 Pilot Pen V5 / V7 ( Black ) 68 Pilot Pen V5 / V7 ( Green ) 69 Pin Cushion ( Metalic ) Best Quality 70 Pin Easy Push Bright Electro Nickel Plated 71 Plastic Water Jug Best Quality 72 Paper Memo Holder 73 Punching Machine 74 Pointed Ball Pen ( Red & Blue ) 75 Refill Gel Pen ( Red ) 76 Refill Gel Pen ( Blue ) 77 Refill Gel Pen ( Black ) 78 Refill Gel Pen ( Green ) 79 Round Sealing Wax ( Red ) Best Quality 80 Safety Match Box 81 Scale Wooden06 Inch 82 Scale Wooden12 Inc 83 Scissors For Paper Cutting Best Quality Big Size 84 Sharpner 85 Sinature Pad ( 25 Pages With Board Binding ) 86 Sponge With Plastic Case Best Quality 87 Stamp Pad 88 Stamp Pad Ink ( 60Ml ) 89 Stand Candle ( Medium ) 90 Stapler Machine ( Big 24 / 6 Size ) 91 Stapler Machine ( Small 10 Size ) 92 Stapler Pin ( Big 24 / 6 Size ) 93 Stapler Pin ( Small 10 Size ) 94 Steel Mnual Call Bell 95 Self Adhesive Tape 2 Inch Wide 96 Sketch Pen 97 Table Calling Bell Best Quality 98 Tag Cotton As Per Sample 99 Thread Bal ( Red ) 100 Thread Bal ( White ) 101 Towel Big Size 102 Tvs Cartridges Hd755 Ribbon 103 Tvs Cartridgesprodot Ribbon 104 Tvs Cartridges Hd745 Ribbon 105 Tvs 345 Msp Star Ribbon Pronter Cartridges ( For 136 Collumn 9 / 24 Pin Dot Matrix Printers ) 106 Use And Throw Ball Pen ( Blue ) 107 Use And Throw Ball Pen ( Black ) 108 Use And Throw Ball Pen ( Red ) 109 Use And Throw Pen ( Blue ) 110 Use And Throw Pen ( Black ) 111 Use And Throw Pen ( Red ) 112 Waste Paper Busket ( Plastic ) Best Quality 113 White Paper Dfc Size Andhrapradesh -43X69 Cms. 8.6 Kg 114 White Paper Fc Size 115 White Board Marker Pen 116 Wooden Pencil ( Hard-2B ) 117 Wooden Pencil ( Medium Hb ) 118 Xerox Paper A4 Size Normal Quality 119 Xerox Paper Legal Size Normal Quality 120 Colour Flap 121 Feviquick Gum 122 Fevi Stick Gum 123 Steel Scale 12 Inch 124 Plastic Scale 12 Inch 125 Stapler Machine Hp 45 Big Size 126 Photo Paper 127 Paper Binder Clip Clamp 128 Camlin White Glue 50 Gm 129 Bound Register Ruled 600 Sheets Conquest Pages 130 Bound Register Un-Ruled 600 Sheets Conquest Pages 131 Luxor V-5 Pen 132 Forms ( Part-I ) 133 Bill Register Per Register Containing 200 Sheets With Board Binding Both Side Printing 134 Bill Register And Page Numbering 135 Cl Register Containing 100 Sheets Per Book With Page Numbering Covering With Cloth Binding As Per Sample Copy 136 Challan Form Per 1000 No. Pad Binding 506 Single Side Printing 137 Contingent Charges Register Per Register Containing 200 Sheets With Cloath Binding Both Side Printing 138 Contingent Charges Register And Page Numbering 139 Attendence Register Per Register Containing 56 Sheets With Cloath Binding Both Side Printing 140 Attendence Register And Page Numbering 141 Bill Ext. Form Per 1000 Numbers Pad Binding 500 Sheets ( Single Side Printing ) 142 Opd Ticket For Hospital Per 1000 Numbers Pad Binding 500 Sheets ( Single Side Printing ) 143 Form Of Leave Account Per 1000 Numbers Pad Binding 500 Sheets ( Singly Side Printing ) 144 Leave Application Per 1000 Numbers Pad Binding 500 Sheets ( Singly Side Printing ) 145 Peon Book Per 1000 Numbers Pad Binding 500 Sheets ( Both Side Printing And Page Numbering ) 146 Master Roll Per Register Containing 200 Sheets With Cloth Binding Both Side Printing 147 Master Roll And Page Numbering 148 Master Roll Per Register Containing 100 Sheets With Cloth Binding Both Side Printing 149 Master Roll And Page Numbering 150 Master Roll Per Register Containing 150 Sheets With Cloth Binding Both Side Printing 151 Master Roll And Page Numbering 152 Cheque Register Per Register Containing 50 Pages With Boarding As Per Sample ( Both Side Printing ) 153 Form Of Nomination For Death Gratuity Per 1000 Number As Per Sample Copy Including Pad Binding 500 Sheets ( Singly Side Printing ) 154 Committee Register Per Register Containing 200 Sheets With Board Binding ( Both Side Printing ) 155 Admission Of Gpf Form Per 1000 Number As Per Sample Copy Including Pad Binding 500 Sheets ( Single Side Printing ) 156 Service Roll Containing 36 Pages Per Book With Cloth Binding As Per Sample With Page Numbering 157 Form Of Duty Register Containing 500 Pages Per Register With Cloth Binding As Per Sample With Page Numbering 158 Cc Book Containing 100 Pages Per Book In Dublicate Covering With Cloth Binding And Page Numbering 159 Distribution Of Arms Form Per 1000 Numbering With Pad Binding 500 Sheets ( Single Side Printing ) 160 General Diary Book Per 1000 Numbering With Pad Binding 500 Sheets ( Single Side Printing ) 161 El Register Containing 200 Pages Per Book Cobvering With Cloth Binding As Per Sample. 162 Ext. Acquaintance Roll ( Wbf No. 5214 ) Per 100 Numbers With Pad Binding 500 Copies Single Side Printing 163 Cover File Double Plastic Coated 164 Folder File Double Plastic Coated 165 File Flap Double Plastic Coated 166 Order Book Containing 100 Pages Per Book Covering With Board Binding Page Numbering And Single Side Printing 167 Form Of Salary Statement Of Income Tax Per 1000 Numbers As Per Sample Copy Including Pad Binding 500 Copies ( Both Side Printing ) 168 Form Of Salary Statement Of The Employees Per 1000 Numbers As Per Sample Copy Including Pad Binding 500 Copies ( Both Side Printing ) 169 Form Of Submission Income Tax Statement ( Form-16 ) Per 1000 Numbers As Per Sample Copy Including Pad Binding 500 Copies ( Both Side Printing ) 170 Stock Book Of Departmental Containing 1000 Pages Per Register With Cloth Binding As Per Sample. 171 Tr Form No.-50 Per 1000 Numbers With Pad Binding 500 Copies ( Single Side Printing ) 172 Tender Bookcontaining 300 Pages Per Register With Board Binding ( Both Side Printing ) 173 Drivers Car Diary Containing 50 Pages Per Diary. 174 Tr Form No.-21 Per 1000 Numbers As Per Sample Including Pad Binding 500 Sheets ( Both Side Printing ) 175 Morning Report ( Dg & Igp Cr. Wb ) =W= Dig ( Ap ) Bkpore =W= Dg & Igp ( Ap ) Wb Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 176 Morning Report Dig ( Ap ) Nb Slg =W= Dg & Igp ( Ap ) Wb =W= Igp ( Ap ) Nb Slg Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 177 Morning Report Igp ( Ap ) Nb Slg =W= Dig ( Ap ) Nb Slg =W= Dg & Igp ( Ap ) Wb Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 178 Morning Report Of Sap 4Th Bn., Kasba, Raiganj, Uttar Dinajpur Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 179 Ammunition Formper 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 180 Issue Voucher Form Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 181 Casualty Form Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 182 Receipt For Payment W.B.P.M.I.P. Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 183 B Declaration For Pa Claim Form Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 184 Declaration Of Family Particulars Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. 185 Firing Registers 100 Pages Board Binding 186 Allotment Register 150 Pages Board Binding 187 Order Book 400 Pages Board Binding 188 Order Book 200 Pages Board Binding 189 Orderly Room Register 100 Pages Board Binding 190 Pd Book 100 Pages ( Single Side Printing With Duplicate ) 191 Inspection Report Book ( Wbf No. 5308 Big Size ) 107 Pages Board Binding 192 Inspection Report Book ( Wbf No. 5308 Legal Size ) 100 Pages Board Binding 193 Gpf Register 700 Pages 194 Cash Book 300 Pages 195 Rubber Stamp 196 El Register 300 Pages 197 El Register 100 Pages 198 Letter Pad 70 Pages 199 Leaflet ( Both Side ) 100 Pcs 200 Bill Transit Register 100 Pages 201 Clothing Hand Book Wbp Form No. 5341 ( 25 Pages ) 202 Receipt For Payment Of Electric Current Charges 100 Pages 203 Service Bookcontaining 43 Pages Per Book With Cloth Binding As Per Sample With Page Numbering 204 Form Of Tender 500 Pages 205 Weekly Pending List ( Form No. 203 ) 100 Pages 206 Stock Book Of Forms 300 Pages Per Register With Cloth Binding 207 Stock Book Of Stationary Articles 200 Pages Per Register With Cloth Binding 208 Received Register Per Register Containing 400 Sheets With Board Binding ( Both Side Printing ) 209 Despatch Rigister Per Register Containing 400 Sheets With Board Binding ( Both Side Printing ) 210 Register Of Contingent Charges Wb Form No. 2401 ( 324 Pages ) 211 Register Of Contract Contingent Charges Wb Form No. 2402 ( 100 Pages ) 212 Clothing Stock Book 200 Pages 213 Duty Register Per Register Containing 100 Sheets With Binding Both Side Printing And Page Numbering 214 Envelope ( 9.5 X 4.5 ) Plain Small 100 Pc Per Bundle 215 Envelope Ordinary ( 6 X 12 ) Plain 100 Pc Per Bundle 216 Envelope ( 16 X 12 ) 100 Pc Per Bundle 217 Envelope Big Size ( Cloth ) 100 Pc Per Bundle 218 Envelope A4 Size 100 Pc Per Bundle 219 Gpf Register 600 Pages ( Binding With Cloth Cover ) 220 Gpf Register 400 Pages ( Binding With Cloth Cover ) 221 Register Of Proceeding 100 Pages Per Book 222 Register Of Casualities 100 Pages Per Book 223 Training Data Form 500 Pages ( 01 Rim ) 224 Cl Register Containing 200 Sheets Per Book With Page Numbering Covering With Cloth Binding As Per Sample Copy 225 Ta Bill Register ( Formate ) 300 Pages 226 Trodat Stamp 227 Note Sheet 100 Pages With Sl No. 228 Pocket Diary 229 Ta Bill Register ( Formate ) 200 Pages 230 Do Letter Pad 70 Pages 231 100 Point Register With Binding ( 300 Pages ) 232 Held Over Register With Binding ( 200 Pages ) 233 Brown Target Paper 234 White Binding Paper 235 Office Diary 236 Book Binding ( Hard Cover Binding ) 100 Pages 237 Book Binding 100 Pages 238 Book Binding ( Cloth Binding ) 100 Pages 239 Book Binding ( Normal Binding ) 100 Pages 240 Book Binding ( Spiral Binding ) 100 Pages 241 Year Diary ( Times ) 242 Executive Diary 243 Wall Calender Printing 244 Miscellaneous Articles ( Part-Ii ) 245 Ro+Uv + Uf ( 07 Ltr. Store + 15Ltr. / Hr Purify ) 246 Ro+Uv + Uf +Tds ( 10 Ltr. Store + 15Ltr. / Hr Purify ) 247 Water Purifier Machine 248 Repair Of Water Purifier Machine 249 Ro Membren 250 Sediment 251 Carbon 252 Frt 253 Booster Pump 254 Sounoid Valve 255 Tds Controller 256 Sensor Float Valve 257 Ccb 258 Uv Lamp 259 Uv Housing 260 Main Wire 261 Smps 262 Iron Removal 263 Uf Membren 264 Post Carbon 265 Carbon Of Water Purifier Machine 266 Bandage 2½ 267 Battery 750 268 Battery 750 269 Battery 750 270 Battery Charger 12 V 2 Amp 271 Battery Charger 12 V 4 Amp 272 Battery Charger 12 V 8 Amp 273 Battery Dry Cell 12Volt. Rechargeable 274 Battery Dry Cell 12Volt. Rechargeable 275 Battery Dry Cell 6 Volt. Rechargeable 276 Battery Dry Cell 6 Volt. Rechargeable 277 Battery ( Medium ) 278 Battery ( Medium ) 279 Battery ( Medium ) 280 Battery ( Pencil ) 281 Battery ( Pencil ) 282 Battery ( Pencil ) 283 Bed Switch 6 Amp. 284 Bell Push Switch ( Box Type ) 285 Black Patching Paper 286 Black Tape ( Pvc ) 287 Water Cooler Ss 20 / 20 With Kent Filter ( Ro + Uf + Tds Controller ) & Repair 288 Repair Of Water Cooler Ss 20 / 40 289 Water Cooler Ss 40 / 80 ( Ro + Uf + Tds Controller ) & Repair 290 Water Cooler Ss 40 / 80 ( Ro + Uf + Tds Controller ) Repair 291 Briefcase 292 Briefcase 293 Candle ( Big Size ) 6 Pcs. Pkd. 294 Carbon Filter 295 Casserole 1 Ltrs. 296 Casserole 2.5 Ltrs. 297 Casserole 4 Ltrs. 298 Casserole 5 Ltrs. 299 Casserole 10 Ltrs. 300 Ceiling Fan 48 301 Ceiling Fan 48 302 Ceiling Fan 48 303 Ceiling Fan 52 304 Ceiling Fan 52 305 Ceiling Fan 52 306 Ceiling Fan Regulator 307 Ceiling Fan Regulator 308 Ceiling Fan Regulator 309 Ceiling Fan Repairing And Coil Binding 310 Condenser Forceiling Fan 311 Pedestal Fan 312 Pedestal Fan 313 Pedestal Fan Repairing And Coil Binding 314 Electronics Regulator For Fan 315 Portable Rough Pad Rewrteable 316 Paper And Card Shredder 317 File Desk Tray 318 Cello Tape 319 Paper Holding Binder Clip 320 Plastic Storage Clip Board 321 Cheque Book Holder 322 Sticky Note Pad Large 323 Sticky Note Pad Small 324 Led Rice Lamp 325 Rice Lamp 326 Cup Platemedium Quality ( 6 Pcs Set ) 327 Cup Plate ( Bone China ) Good Quality ( 6 Pcs Set ) 328 Detergent Cake 100 Gm 329 Detergent Cake 250 Gm 330 Dinner Plate ( Bone China ) 6 Pcs. Set 331 Dinner Set ( Bone China ) Good Quality 332 Electric Kettle 1 Ltrs. 333 Electric Kettle 1 Ltrs. 334 Electric Kettle 2 Ltrs. 335 Electric Kettle 2 Ltrs. 336 Electric Kettle 4 Ltrs. 337 Electric Kettle 4 Ltrs. 338 Emergency Light 6 Volt 339 Emergency Light 6 Volt 340 Extension Cord ( Skill ) 07 Mtrs. 341 Extension Cord For Computer ( 7 Point ) 342 ( Ddl ) Tube / Container Small 343 Fevicol ( Ddl ) Tube / Container Medium 344 Flask 1 Ltrs. 345 Flask 1 Ltrs. 346 Flask 2 Ltrs. 347 Flask 2 Ltrs. 348 Lock ( ( Navtal ) , 4 Lvs 349 Lock ( ( Navtal ) 6 Lvs 350 Lock ( ( Navtal ) , 7 Lvs 351 Lock ( ( Navtal ) , 8 Lvs 352 Graphic Board 353 Graphic Board Figure½ 354 Graphic Board Figure 1 355 Graphic Board Letter ½ 356 Graphic Board Letter 1 357 Led Bulb 15 Watt 358 Led Bulb 15 Watt 359 Led Bulb 20 Watt 360 Led Bulb 20 Watt 361 Led Bulb 9 Watt 362 Led Bulb 9 Watt 363 Led Bulb 30 Watt 364 Led Bulb 30 Watt 365 Led Bulb 40 Watt 366 Led Bulb 40 Watt 367 Led Halogen 100 Watt 368 Led Halogen 100 Watt 369 Led Halogen 50 Watt 370 Led Halogen 50 Watt 371 Led Halogen 70 Watt 372 Led Halogen 70 Watt 373 Led Tube Set 2 374 Led Tube Set 2 375 Led Tube Set 4 376 Led Tube Set 4 377 Measuring Tape ( Steel ) 25 Mtrs. 378 Measuring Tape ( Steel ) 75Mtrs. 379 Measuring Tape ( Steel ) 100 Mtrs. 380 Measuring Tape6 381 Measuring Tape 20 382 Measuring Tape 50 383 Measuring Tape 100 384 Metal Bulb 250 Watt 385 Metal Bulb 500 Watt 386 Metal Choke 250 Watt 387 Metal Choke 500 Watt 388 Metal Lamp Complete Set 250 Watt 389 Metal Lamp Complete Set 500 Watt 390 Microphone 391 Microphone Cordless 392 Microphone Transistor ( Ahuja ) 80 Watt 393 Microphone Transistor 100 Watt 394 Microphone Transistor 120 Watt 395 Mike Set Unit And Horn 396 Sound Box50 Watt 397 Sound Box 80 Watt 398 Sound Box 100 Watt 399 Sound Box 120 Watt 400 Microphone Stand 401 Microphone Stand 402 Mixer Grinder 403 Mixer Grinder 404 Ors 15 Mg Pouch 405 Ors 20 Mg Pouch 406 Ors 25 Mg Pouch 407 Ors 50 Mg Pouch 408 Ors- L ( Pouch ) 409 Phenyl 410 Phenyl 411 Phenyl 412 Pvc Tape ( Big Roll ) 413 Revibe ( Big Size ) 414 Room Freshener 375 Ml. 415 Room Freshener 375 Ml. 416 Sanitizer 417 Steiner 200 Ml. Bot. 418 Starter For Ac 18-25 Amp 419 Starter For Ac 25 Amp ( 2 Ton ) 420 Starter For Ac 25 Amp 2 Ton 421 Ac Machine Copper Pipe 422 Stop Watch ( Digital ) 423 Dslr Camera 424 Dslr Camera 425 Thermo Flask 1 Ltrs 426 Thermo Flask 1 Ltrs 427 Thermo Flask 2 Ltrs 428 Thermo Flask 2 Ltrs 429 Tiffin Carrier Four Container ( Steel ) 430 Wall Clock 431 Wall Clock 432 Weight Machine ( For Articles ) 5 Kg Capacity With Units 433 Weight Machine Digital 434 Zeoline 50 Ml Bot. 435 Zeoline 100 Ml Bot. 436 Zeoline 200 Ml Bot. 437 Name Plate Brass Made 438 Name Plate Board Plastic 439 Name Plate Board Wooden 440 Name Plate ( Embroidery ) 441 Succession Board Fiber 442 Succession Board Wood 443 Succession Board Printing 444 Angle Drill 445 Arms Rack 10 Pcs. Rifle 446 Arms Rack10 Pcs. Rifle 447 Arms Rack 10 Pcs. Rifle 448 Arms Rack 10 Pcs. Rifle 449 Arms Rack 16 Pcs. Rifle 450 Arms Rack 16 Pcs. Rifle 451 Arms Rack 16 Pcs. Rifle 452 Arms Rack 16 Pcs. Rifle 453 Arms Rack 20 Pcs. Rifle 454 Arms Rack 20 Pcs. Rifle 455 Arms Rack 20 Pcs. Rifle 456 Arms Rack 20 Pcs. Rifle 457 Pencil 458 Pencil 459 Pencil 460 Art Paper 461 Flex / Banner 462 Basket Plastic 463 Bed Cover ( Double ) 464 Bed Cover ( Double ) 465 Bed Cover ( Single ) 466 Bed Cover ( Single ) 467 Bed Sheet ( Double ) 468 Bed Sheet ( Double ) 469 Bed Sheet ( Single ) 470 Bed Sheet ( Single ) 471 Black Board Small 472 Black Board Medium 473 Black Board Big 474 Black Board Stand ( Iron ) 475 White Board Small 476 White Board Medium 477 White Board Big 478 Black Board Stand ( Wooden ) 479 Black Board Stand ( Wooden ) 480 Black Fluorescent Tape 1 481 Black Target Paper 482 Blinker ( Solar ) 483 Blinking Light / Bleker 484 Bone Dust 485 Bowl Set ( Bone China ) 486 By-Cycle All Accessories For Gents 487 By-Cycle All Accessories For Ladies 488 By-Cycle Rim 489 By-Cycle Tube ( Nylon ) 490 By-Cycle Tyre ( Nylon ) 491 By-Cycle Pumper 492 Coffee Cup Small 493 Coffee Cup Medium 494 Coffee Glass 495 Coffee Mug 496 Cotton 100 Gm Pkd. 497 Cotton Mattress 498 Cotton Mattress 499 Dustbin ( Use Me ) 14G.I. Sheet 500 Dustbin ( Use Me ) 18 G.I. Sheet 501 Dustbin Plastic ( Leg Press ) Big 502 Dustbin Plastic ( Leg Press ) Medium 503 Dustbin Plastic ( Leg Press ) Small 504 Duster Cloth 505 Emery Paper 506 Fiber Glass 4 Mm Standard 507 Fiber Plate Small 508 Fiber Plate Small 509 Fiber Plate Medium 510 Fiber Plate Large 511 Fiber Sheet 512 Fiber Tray 513 Fire Bucket 12 514 Fire Bucket 18 515 Fire Extinguisher Refilling ( 2 Kg. ) 516 Fire Extinguisher Refilling ( 5 Kg. ) 517 Fire Extinguisher Refilling ( 9 Kg. ) 518 First Aid Box ( Medium Size ) With All Necessary Equipment And Medicine 519 Flower Vase 22 Brass 520 Folding Chair ( Steel ) 521 Folding Cot ( Nylon Fita ) 522 Folding Table ( Moulded ) 523 Gala ( Seal Wax ) 524 Glass 3 Cell Torch 525 Glass Bowl 526 Glass Lid 527 Glow Sign Board Complete Fitting 528 Glow Sign Board Complete Fitting 529 Hand Sanitiser Dispensing Machine With Temperature Detection 530 Hand Towel ( Standard Size ) 531 Height Measuring Stand ( Metal ) 532 Hurricane Lantern ( Local Made ) 533 Hurricane Lantern ( Kissan ) 534 Infrared Digital Thermometer 535 Iron Door Frame 536 Iron Door Frame With Palla 537 Iron Grill 538 Iron Made Arms Rack 539 Jurricane ( Pvc ) 5 Ltrs. 540 Letter Punch ( A To Z ) Brass & Steel 541 Liquid Measuring Equipment 542 Magnifying Glass 543 Markin Cloth 544 Mask ( N-95 ) 545 Mask ( Cloth ) 546 Mask ( Surgical ) 547 Mirror Small 548 Mirror Medium 549 Mirror Long 550 Moulded Centre Table 551 Moulded Chair With Cushion 552 Moulded Chair With Handle 553 Moulded Chair Without Handle 554 National Flag 555 Pad Lock 5 Lvr. 556 Pad Lock 6 Lvr. 557 Pad Lock 7 Lvr. 558 Pad Lock 8 Lvr. 559 Paper Weight ( Marble ) 560 Paper Weight ( Plastic ) 561 Ply Board ( Commercial ) 562 Ply Board ( Kit ) 563 Wooden Furniture 564 Wooden Furniture 565 Wooden Furniture 566 Scissors For First Aid Box Small 567 Scissors For First Aid Box Medium 568 Scissors For First Aid Box Large 569 Scissors ( Tailors ) 570 Sealing Punch Machine 571 Side Pillow 572 Side Pillow Cover 573 Head Pillow 574 Head Pillow With Cover 575 Steel Scale 12 576 Spoon Set ( V.I.P.Steel ) 577 Spoon Set Plastic Handle 578 Steel Spoon ( Big ) Vip 579 Steel Fork Good Quality Small 580 Steel Fork Good Quality Big 581 Steel Spoon ( Medium ) Vip 582 Steel Spoon ( Small ) Vip 583 Steel Tray 584 Sutli 585 Tea + Biscuit 586 Tea Container 05 Ltrs. 587 Tea Container 10 Ltrs. 588 Tea Container 15 Ltrs. 589 Tea Set ( Bone China ) Good Quality 590 Tiles ( Grade - 1 ) 591 Tissu Paper 592 Tissu Paper For Toilet 593 Towelgood Quality Standard Size 594 Towelgood Quality 24 595 Towelgood Quality 72 596 Transparent Table Cloth ( Standard Size ) 597 Umbrella Big Size 598 Wall Mounted Digital Thermometer 599 Water Glass 06 Pcs. Set 600 Water Glass 06 Pcs. Set 601 Water Bottle ( 1 Ltr. ) 602 Water Bottle ( 500 Ml. ) 603 Water Bottle ( 250 Ml. ) 604 White Table Cloth ( Cotton ) 605 Furniture 606 Furniture 607 Furniture 608 Wrist Band 609 Water Drum ( 20 Ltrs ) 610 Water Drum ( 20 Ltrs ) 611 Tarpaulin Covering 612 Hessian Covering 613 Temporary Marker Pen For White Board 614 Duster For White Board 615 Barbed Wire Bamboo Fencing Apart Vertically In Four Rows And Fixed With Strong Bamboo Posts 616 Single Slope Kitchen Pandel Bamboo Frame Works Shed With Tarpaulin And Others Fitting Same Four Side Covering 617 White Board Big 618 White Board Mediam 619 White Board Small 620 Hiring Charges Of Ceilling Fan With Fitting 621 Hiring Charges Of Pedestal Fan With Fitting 622 Hiring Charges Of Jhar Fan With Fitting ( 28 ) Dia. 623 Hiring Charges Of Tulu Pumpwith Fittings. 624 Hiring Charges Of Tube Light 625 Hiring Charges Of Metal Light 626 Tv Hairing 627 Hairing Chair 628 Hiring Executive Chair 629 Hiring Table 630 Hiring Cooler Machine 631 Hiring Heater 632 Cost Of Window And Door Covering With Polythene With All Accessories. 633 Boil Egg ( 01 Pc. ) 634 Cake ( 01 Pc. ) 635 Banana ( 02 Pcs. ) 636 Sweets- ( 01 Pc. ) 637 Snacks 638 Vip Chair Hiring 639 Vip Table Hiring 640 A.C Machine Servicing And Gas Filling 641 Iron Cot Repairing Including Painting 642 Ply Green Panelling In Wall 643 Ply Normal Panelling In Wall 644 Falls Ceiling With Fitting And Painting 645 Floor Fitted With Vitrified Tiles And Skirting 646 Gala Stamp 647 Temporary Furniture WorkS 648 Wooden Door With Brass Lock And Handle 649 Aluminium Frame Fitted With Glass Door ( 5 X 2 ) 650 Aluminium Frame Fitted With Glass Window ( 4 X 3 ) For Each Window 651 Wooden Book Self ( 6 X 3 ) 652 Glass For Centre Table 653 Wardrobes 654 To Make New Ceiling By Ply Board Without Frame Works With Labour Charges 655 Wooden Door Repair 656 Floor Mat 657 Sanitizer 658 Oxygen Cylinder 14 Ltrs 659 Xerox Machine-Repair 660 Xerox Machine-Repair 661 Xerox Machine 662 Xerox Machine Ir 2004 Repairing ( Image Runner ) 663 Paper / File Maintenance Software With 2 Years Maintenance 664 Typing Software With 2 Years Mainantence 665 Projector With Screen ( Hd ) 666 Projector With Screen ( Hd ) 667 Projector Machine With Screen 668 Projector Machine Repairing 669 Adsl Wireless Router With Modem 670 Adsl Wireless Router With Modem 671 Adsl Wireless Router With Modem 672 Dvd Writer 673 Smps 674 Smps 675 Smps 676 Smps 677 Smps 678 Smps 679 Smps 680 Smps 681 Smps 682 Smps 683 Switch Port 16 684 Switch Port 24 685 Internet Cable Wire 686 Router Power Adapter 687 External Usb Port 688 Printer Cable 689 Printer Cable 690 Printer Cable 691 Printer Cable 692 Printer Cable 693 Scanner 694 Scanner 695 Scanner Repairing 696 Scanner Repairing 697 Scanner Repairing 698 Scanner Repairing 699 Scanner Repairing 700 Scanner Repairing 701 Scanner Repairing 702 Colour Printer 703 Colour Printer 704 Fax Machine Repair 705 Photography Paper 706 Pen Drive 32 Gb 707 Pen Drive 64Gb 708 Pen Drive 128 Gb 709 Blank Plastic Cd Cover 710 Dox-Cable Cat-6 711 External Hard Disk 1 Tb 712 External Hard Disk 2 Tb 713 External Hard Disk 500 Gb ( Hp ) 714 Blank Cd 715 Blank Cd 716 Dvd 717 Dvd 718 Mouse Pad 719 Cabinet With S.M.P.S- 450 Watt 720 Cabinet With S.M.P.S- 450 Watt 721 Cabinet With S.M.P.S- 450 Watt 722 Mother Board H110m-S2 723 Mother Board H110m-S2 724 Processor- I3 725 Processor- I3 726 Processor- I5 727 Processor- I5 728 Processor- I7 729 Processor- I7 730 Ram - 4 Gb Ddr-Iii 731 Ram - 4 Gb Ddr-Iii 732 Ram - 4 Gb Ddr-Iii 733 Ram - 4 Gb Ddr-Iii 734 Ram - 4 Gb Ddr-Iii 735 Ram - 4 Gb Ddr-Iii 736 Ram - 4 Gb Ddr-Iii 737 Ram - 4 Gb Ddr-Iii 738 Ram - 8 Gb Ddr-Iii 739 Ram - 8 Gb Ddr-Iii 740 Ram - 8 Gb Ddr-Iii 741 Ram - 8 Gb Ddr-Iii 742 Ram - 8 Gb Ddr-Iii 743 Ram - 8 Gb Ddr-Iii 744 Ram - 8 Gb Ddr-Iii 745 Ram - 8 Gb Ddr-Iii 746 Ram - 4 Gb Ddr-Iv 747 Ram - 4 Gb Ddr-Iv 748 Ram - 4 Gb Ddr-Iv 749 Ram - 4 Gb Ddr-Iv 750 Ram - 4 Gb Ddr-Iv 751 Ram - 4 Gb Ddr-Iv 752 Ram - 4 Gb Ddr-Iv 753 Ram - 4 Gb Ddr-Iv 754 Ram - 4 Gb Ddr-Iv 755 Ram - 4 Gb Ddr-Iv 756 Ram - 4 Gb Ddr-Iv 757 Ram - 4 Gb Ddr-Iv 758 Ram - 4 Gb Ddr-Iv 759 Ram - 4 Gb Ddr-Iv 760 Ram - 4 Gb Ddr-Iv 761 Ram - 4 Gb Ddr-Iv 762 Ram - 8 Gb Ddr-Iv 763 Ram - 8 Gb Ddr-Iv 764 Ram - 8 Gb Ddr-Iv 765 Ram - 8 Gb Ddr-Iv 766 Ram - 8 Gb Ddr-Iv 767 Ram - 8 Gb Ddr-Iv 768 Ram - 8 Gb Ddr-Iv 769 Ram - 8 Gb Ddr-Iv 770 Ram - 8 Gb Ddr-Iv 771 Ram - 8 Gb Ddr-Iv 772 Ram - 8 Gb Ddr-Iv 773 Ram - 8 Gb Ddr-Iv 774 Ram - 8 Gb Ddr-Iv 775 Ram - 8 Gb Ddr-Iv 776 Ram - 8 Gb Ddr-Iv 777 Ram - 8 Gb Ddr-Iv 778 Hdd Drive ( Internal ) 1Tb- Satta 779 Hdd Drive ( Internal ) 1Tb- Satta 780 Hdd Drive ( Internal ) 1Tb- Satta 781 Hdd Drive ( Internal ) 1Tb- Satta 782 Hdd Drive ( External ) 1Tb-Usb 783 Hdd Drive ( External ) 1Tb-Usb 784 Hdd Drive ( External ) 1Tb-Usb 785 Hdd Drive ( Internal ) 500 Gb 786 Hdd Drive ( Internal ) 500 Gb 787 Hdd Drive ( Internal ) 500 Gb 788 Hdd Drive ( External ) 500 Gb 789 Hdd Drive ( External ) 500 Gb 790 Dvd Writer 791 Dvd Writer 792 Ups 600 Va 793 Ups 600 Va 794 Ups 800 Va 795 Ups 800 Va 796 Ups Battery - 12 Volt 7Amp 797 Key Board 798 Key Board 799 Key Board 800 Mouse 801 Mouse 802 Mouse 803 Bios Battery -3 Volt 804 Monitor 19.5 Led 805 Monitor 19.5 Led 806 Monitor 19.5 Led 807 Monitor 19.5 Led 808 Monitor 21 Led 809 Monitor 21 Led 810 Monitor 21 Led 811 Monitor 21 Led 812 Monitor 32 Led 813 Monitor 32 Led 814 Monitor 32 Led 815 Monitor 32 Led 816 Printer ( Dot Matrix ) - 817 Leaser Printer Ink 818 Leaser Printer Ink 819 Dot Matrix Printer Head - T.V.S 820 Dot Matrix Printer Head - T.V.S 821 Taflon Paper Of Laser Printer Hp 822 Printer ( Laser Jet 1020 Plus ) Hp 823 Tab 824 Tab 825 Wireless Mouse 826 Wireless Mouse 827 Wireless Mouse 828 Printer Laser Jet P1007 829 Printer Laser Jet P1007 830 Printer Cartridges 831 Printer Ribbon Tvs - Msp 345 Star 832 Computer Table 833 Computer Ribbon Cartridge Lq-664 834 Colour Printer 835 Colour Printer 836 Colour Printer 837 Colour Printer-Ink 838 Colour Printer-Ink 839 Colour Printer-Ink 840 Colour Printer Head 841 Fax Machine 842 Broad Band Modem 843 Printer Refilling 844 Printer Refilling 845 Printer Refilling 846 Riffling Of Cartridge 847 Riffling Of Cartridge 848 Riffling Of Cartridge 849 Hdmi Splitter 850 Hdmi Cable 851 Cat -6 Lan Cable 852 Rj 45 Connector 853 Laptop 854 Laptop 855 Laptop Battery 856 Laptop Battery 857 Laptop Battery 858 Laptop Battery 859 Anti Virus ( 1User 1Yr ) 860 Anti Virus ( 1User 1Yr ) 861 Anti Virus ( 1User 3Yr ) 862 Anti Virus ( 1User 3Yr ) 863 Anti Virus ( 3User 3Yr ) 864 Anti Virus ( 3User 3Yr ) 865 Anti Virus ( 5 User 3Yr ) 866 Anti Virus ( 5 User 3Yr ) 867 Speaker Box 868 Speaker Box 869 Dongle Usb Modem 870 Dongle Usb Modem 871 Dongle Usb Modem 872 Dongle Usb Modem 873 Cloud Router 874 Cloud Router 875 8 Port Switch Multi Hub 876 Operating System-Multiuser 877 Operating System 878 Operating System 879 External Usb Port 880 Switching Box For Multi Connection Of Net 881 Wifi Dongle 882 Wifi Dongle 883 Wifi Dongle 884 Usb To Lan Port / Card 885 Usb To Lan Port / Card 886 Usb To Lan Port / Card 887 C.C.T.V. Camera 888 8 Ch Nvr 889 16 Ch Nvr 890 32 Ch Nvr 891 Ip 4Mp Bullet 892 4 Port Poe 893 8 Port Poe 894 Ip 4Mp Dome 895 Cat 6 Wire 896 Dvr Lock Box 897 C.C.T.V. Cable & Wire 898 Coaxialcable 899 C.C.T.V. Connector 900 Digital Video Recorder 901 Dc Power Cable 902 Video Baluns 903 Security Camera Microphone 904 C.C.T.V. Video Multiplexers 905 Wireless Video Transmitters 906 Security Camera Lens 907 Siamese Cable 908 Telephone Receiver 909 Telephone Receiver 910 Telephone Receiver Color Id 911 Telephone Receiver Color Id 912 Set Top Box-Digital / Hd With Recoding-1 Yrs. Package With Full Channals 913 Set Top Box-Digital / Hd With Recoding-1 Yrs. Package With Full Channals 914 Disk Tv Monthly Recharge 915 Disk Tv Monthly Recharge 916 Jio Fiber Monthly Recharge 917 Mobile Phone-Android With Gps Facility Withcamera 918 Mobile Phone-Android With Gps Facility Withcamera 919 Mobile Phone-Android With Gps Facility Withcamera 920 Mobile Phone-Android With Gps Facility Withcamera 921 Steel Almirah ( Big Size ) 78”X36”X22” 922 Steel Almirah ( Medium Size ) 60”X36”X20” 923 Book Self ( 78”X36”X22” ) Wooden 924 Book Self ( 78”X36”X22” ) Steel 925 Filing Cabinet ( 60”X36”X20” ) 926 Steel Rack ( 45X61X22 ) 927 Steel Table 928 Executive Table 929 Wooden Table 930 Wooden Table 931 Wooden Table 932 Wooden Table 933 Wooden Table 934 Wooden Rack 935 Wooden Rack 936 Wooden Rack 937 Wooden Rack 938 Wooden Rack 939 Wooden Rack 940 Wooden Rack 941 Wooden Chair 942 Wooden Chair 943 Wooden Chair 944 Wooden Chair 945 Wooden Chair 946 Wooden Chair 947 Wooden Chair 948 Steel Chair 949 Plastic Chair 950 Executive Chair ( Big Size ) 951 Executive Chair ( Small Size ) 952 Revolving Chair 953 Computer Chair 954 Computer Chair ( Without Arm ) 955 Fiber Chair 956 Fiber Chair ( Without Arm ) 957 Fiber Table 958 Wooden Tool 959 Wooden Back Bench 960 Fiber Tool 961 Table Glass ( 5 Mm / 8Mm ) 962 Wooden Rifle Rack 10 Capacity With Single 963 Wooden Rifle Rack 10 Capacity With Single 964 Wooden Rifle Rack 10 Capacity With Single 965 Wooden Rifle Rack 10 Capacity With Double 966 Wooden Rifle Rack 10 Capacity With Double 967 Wooden Rifle Rack 10 Capacity With Double 968 Wooden Rifle Rack 20 Capacity With Single 969 Wooden Rifle Rack 20 Capacity With Single 970 Wooden Rifle Rack 20 Capacity With Single 971 Wooden Rifle Rack 20 Capacity With Double 972 Wooden Rifle Rack 20 Capacity With Double 973 Wooden Rifle Rack 20 Capacity With Double 974 Office Chair Plastic 975 Wooden Dining Table 976 Wooden Dining Table 977 Wooden Dining Table 978 Wooden Dining Bench 979 Wooden Dining Bench 980 Wooden Dining Bench 981 Notice Board With Glass 982 Steel Bench 983 Display Board 984 Map Board 985 Door Mats 986 Wall Cabinet 987 Side Cabinet 988 Hang Mirror 989 Door & Window Curtain With Fittings 990 Door & Window Curtain With Fittings 991 Wooden Cot 992 Wooden Cot 993 Wooden Cot 994 Wooden Cot 995 Almirah Lock Repairing 996 Photo Binding With Mirror 997 Cellotape With Cutter 998 Cup & Plate 999 Cup & Plate 1000 Date Stamp With Lock 1001 Desk Cellender 1002 Desk Cellender Stand 1003 Drinking Glass 1004 Drinking Glass 1005 Punching Machine Big 1006 Punching Machine Mideum 1007 Sealing Wax 1008 Table Tray 1009 Table Top 1010 Bill Register200 Sheet 1011 Black & White Printing A-4 Paper 1012 Black & White Printing Legal Paper 1013 Colour Printing A-4 Paper Ban Paper 1014 Pocket Diary 1015 Colour Photo Print ( 4 / 6 ) 1016 Colour Photo Print ( 5 / 7 ) 1017 Colour Photo Print ( 8 / 10 ) 1018 Colour Photo Print ( 8 / 12 ) 1019 Iron Trunk 1020 Hipping Hammer 1021 Serch Light / Dragon Light Cherger 1022 Wax 1023 Sandwich Maker 1024 Sandwich Maker 1025 Sandwich Maker 1026 Toaster 1027 Toaster 1028 Toaster 1029 Toaster 1030 Dinner Set 1031 Dinner Set 1032 Dinner Set 1033 Wall Hanger 1034 Hot Pot Bowl 1035 Hot Pot Bowl 1036 Table Mat 1037 Exhaust Fan 1038 Exhaust Fan 1039 Exhaust Fan 1040 Exhaust Fan 1041 Exhaust Fan Repairing 1042 Desk Organiser 1043 Tv 32 1044 Tv 32 1045 Tv 32 1046 Tv 43 1047 Tv 43 1048 Tv 43 1049 Tv 55 1050 Tv 55 1051 Tv 55 1052 Tv 60 1053 Tv 60 1054 Tv 60 1055 Mobile Power Bank 10000 Mah 1056 Mobile Power Bank 10000 Mah 1057 Mobile Power Bank 20000 Mah 1058 Mobile Power Bank 20000 Mah 1059 Mobile Power Bank 27000 Mah 1060 Mobile Power Bank 27000 Mah 1061 Mobile Charger 1062 Furniture Painting 1063 Furniture Painting 1064 Furniture Painting 1065 Green Tea 1066 Coffee 1067 Darjelling Tea 1068 Sweets 1069 Biscuit 1070 Sugar Cube 1071 Rice 1072 Dal 1073 Fish 1074 Vaja 1075 Chatni 1076 Sweets 1077 Books 1078 Bicycle 1079 Broad Band Connection + Installation + Monthly Package 1080 Normalbook Binding 1081 Hard Cover Book Binding 1082 Cloth Book Binding 1083 Spiral Book Binding 1084 Wooden Bench 1085 Wooden Bench 1086 Wooden Bench 1087 Wooden Low Bench 1088 Wooden Low Bench 1089 Wooden Low Bench 1090 Cup Plate Set ( Bone China ) 1091 Ash Tray 1092 Microtek Intel Pure Sine Wave 1625 W E2+ Inverter With 150 Amp It 500 ( Exide ) Battery & Trolley 1093 Microtek Intel Pure Sine Wave 1625 W E2 Repairing 1094 Microtek 1825 E2 Sine Wave Inverter With 02 No. 150 Amp It 500 ( Exide ) Battery & Trolley 1095 Microtek 1825 E2 Sine Wave Inverterrepairing 1096 Microtek 1225 E2 Inverter With 01 No. 150 Amp It 500 ( Exide ) Battery & Trolley 1097 Microtek 1225 E2 Inverter Repairing 1098 Invatubllar Battery 150 Amp It 500 ( Exide ) 1099 Microtek E2 + 1625 Va Sine Wave Ups Fy 1813 Inverter With Battery & Trolley 1100 Microtek E2 + 1625 Va Sine Wave Ups Fy 1813 Inverter Repairing 1101 Gastifier Stove 1102 Repair Of Gastifier Stove 1103 Chapatti Vati Machine 1104 Repair Of Chapatti Vati Machine 1105 Wooden Table & Rack 1106 Wooden Table & Rack 1107 Wooden Table & Rack 1108 Ornate Chair 1109 Jute Sack 1110 Target Paper 1111 Figure 11 1112 Repairing Of Furniture 1113 Repairing Of Furniture 1114 Sprite Polish Of Wooden Door 1115 Polishing & Colouring Of Furniture Wooden 1116 Polishing & Colouring Of Furniture Steel 1117 Uniball Pen All Colour 1118 Year Diary 1119 Executive Diary 1120 Wall Calendar Printing 1121 Sofa Set One Sitter 1122 Sofa Set Three Sitter 1123 Centre Table Wooden With Glass Fittin 1124 Centre Table 1125 Kitchen Chimney 1126 Kitchen Chimney 1127 Kitchen Chimney 1128 Microwave 1129 Microwave 1130 Microwave 1131 Microwave 1132 Micro Plate / Bowl 1133 Refrigerator 1134 Refrigerator 1135 Refrigerator 1136 Refrigerator 1137 Hooter 1138 Signature Pad 1139 Pen 1140 Pen 1141 Ball Pen 1142 Permanent Marker Pen For Signature 1143 Steel Buffet 1144 Buffet Gel 1145 Iron Floor And Desk Stand 1146 Pbx Machine 1147 Wooden Desk Calendar 1148 Paper Weight Glass 1149 Paper Weight Plastic 1150 Metal Key Chain 1151 Tissue Paper Holder 1152 Juicer 1153 Juicer 1154 Juicer 1155 Video Camera 1156 Video Camera 1157 Video Camera 1158 Breath Analyzer 1159 Breath Analyzer 1160 Stamp Pad 1161 Hand Towel 1162 Tag ( Long Size ) 1163 Alpin 1164 Saxophone 1165 Clarinet 1166 Trumpet 1167 Euphonium 1168 Euphonium Spring 1169 Big Drum 1170 Side Drum 1171 Side Drum Synthetic 1172 Bugler 1173 Bugler Mouth Piece 1174 Trumpet Mouth Piece 1175 Euphonium Mouth Piece 1176 Bugle Siling 1177 Trumpet Spring 1178 Big Drum Synthetic 1179 Big Drum Biter 1180 Big Drum Siling 1181 Side Drum Stick 1182 Side Drum Siling 1183 Clarinet Bob 1184 Saxophone Bob 1185 Pipe Rid 1186 Chanter Rid 1187 Leather 1188 Wax 1189 Side Drum Synthetic 1190 Side Drum Stick 1191 Side Drum Siling 1192 Big Drum Biter 1193 Big Drum Belt 1194 Tener Drum Biter 1195 Tener Drum Belt 1196 Pipe Don 1197 Lerniar 1198 Solder Cover 1199 Batch 1200 Belt 1201 Shall 1202 Beret Cap 1203 Crown 1204 Pipe Chanter 1205 Practice Chanter 1206 Saxophone Repair 1207 Clarinet Repair 1208 Trumpet Repair 1209 Euphonium Repair 1210 Dress For Brass Band 1211 Dress For Pipe Band 1212 Saxophone Rid 1213 Clarinet Rid 1214 Saxophone Mouth Pice 1215 Clarinet Mouth Pice 1216 Side Drum Spring 1217 Tie 1218 Leather Cover 1219 Flue Pipe 1220 Pipe Cord 1221 Pipe Master Stick 1222 Brass Master Stick 1223 Officer’S Cap 1224 Saxophone Box 1225 Saxophone Neck Strip 1226 Clarinet Box 1227 Trumpet Box 1228 Activated Carbon 1229 Gravels Stone 1230 Mno2 1231 Treated Sand 1232 Anthracite 1233 Clorin 1234 Anti Scelent Chemicals 1235 Add Minerals 1236 Sodium Bicarbonate 1237 5 Micron Jambu Filter 1238 Dosing Pump Pipe 1239 Back Wash Valve 1240 Multiport Valve 1241 Uv System 1242 Ro Membren ( 250Lph ) 1243 Chemical For Washing 1244 Citric Acid 1245 High Pressure Pump ( Cri ) 1246 Raw Water Pump 1247 Pressure Metre 1248 Flow Metre 1249 Vessel 1250 Lesser Pipe 1251 Jambu Filter 1252 Jambu Cartage 1253 Dosing Pump 1254 Electric Panel 1255 1 Hp Raw Pump 1256 Pipe Fitting 1257 Meneral Powder 1258 Silex 1259 Condenser Ac Machine 1260 Compressor Ac Machine 1261 Capacitor Ac Machine 1262 Fan 1263 Gas Change 1264 Pipe 1265 Circuit Change 1266 Sensor 1267 Legal Size Conquest / Ledger Paper 1268 Candle 10” 1269 Iron Cartridge 1270 Classic Block 1271 P.C.B. 1272 Servicing 1273 Candle 10” 1274 Iron Cartridge 1275 Hi Flow Block 1276 P.C.B. 1277 Servicing 1278 Dr. Classic 1279 Uv+Uf ( 6.2 Ltrs. ) 1280 Nxt Uv ( 8.5 Ltrs. ) 1281 Uv ( 7 Ltrs. ) 1282 Ro+Uv ( 6.2 Ltrs. ) 1283 Ro+Uv ( 8.5 Ltrs. ) 1284 Ro+Uv ( 7 Ltrs. ) 1285 Pipe Ribbon 1286 Pipe Lather Cover 1287 Pipe Flag 1288 Pipe Mouth Piece 1289 Clarinet Notation Stand 1290 Trumpet Notation Stand 1291 Saxophone Notation Stand 1292 Music Manuscript Book 1293 Jona Dohar ( Double ) 1294 Jona Dohar ( Single ) 1295 Jona Dohar ( Double ) 1296 Jona Dohar ( Single ) 1297 Small Hand Towel 1298 Blanket ( Double ) 1299 Mattress ( 6’X7’ ) 1300 Mattress ( 5’X6’ ) 1301 Mattress ( 4’X6’ ) 1302 Bracket 1303 Still Pipe For Curtain 1304 Rent Of Cctv Camera 1305 Curtain Cloth 1306 Vacuum Cleaner 1307 Tea Table 1308 Wire Clip 1309 Elastic 1310 Sofa Cover 1311 Switch 6 Amp 1312 Hanger 1313 Table Lamp 1314 Small Towel 1315 Cpu Repair / Servicing 1316 Microwave Oven 1317 Portable Hard Drive ( 1 Tb ) 1318 Geyser ( 10 Ltr. ) 1319 Cd- Rw 1320 Ink Tank 419 Wifi Colour Printer 1321 Antivirus ( For 5 Users 1 Year ) 1322 Ram For Laptop ( 4 Gb ) 1323 Roti Maker Machine 1324 Roti Maker Machine Repairing 1325 Hard Disk 1 Tb 1326 Ssd 256 Gb 1327 Ssd 128Gb 1328 Ssd 1000 Gb 1329 Big Size Towel 1330 Big Size Towel 1331 Processor 1332 Mother Board A32m-H 1333 Ram Ddr4 4Gb 1334 Monitor 27”- Hp ( Full Hd ) 1335 Cache Memory 12 Mb 1336 Processor Frequency1.8 1337 Printer ( Laser Jet Printer Cum Scanner Machine ) 1338 Ups -600W 1339 Distilled Water 1340 Dress Cord 1341 12 Mm. Ply With Sunmica With Fitting And Fixing 1342 18 Mm. Ply With Sunmica With Fitting And Fixing 1343 Printer Cartridge 1344 Tonner 1345 Printer Tonner Refilling With Drum Change ( 12A ) 1346 Succession Board Printing 1347 Moulded Dining Table 1348 Smps With Cabinet 1349 Smps With Cabinet 1350 Smps With Cabinet 1351 Smps With Cabinet 1352 Smps With Cabinet 1353 Smps With Cabinet 1354 Smps With Cabinet 1355 Smps With Cabinet 1356 Smps With Cabinet 1357 Compatible Cartridges 12A 1358 Ups 1Kva 1359 Repairing / Servicing Ofleaser Jet 1020 Printer 1360 Dvd 1361 Table Calendar Printing 1362 Ink Tank 419 Wifi Colour Printer Ink 1363 Mother Board Jumpering / Servicing 1364 4 Port 1365 M.C. ( Media Converter ) 1366 Adapter ( 12 V 2 Amp ) 1367 Adapter ( 05 V 2 Amp ) 1368 Patch Cord 1369 Hdmi To Vga Converter 1370 Wireless Key Board 1371 Wireless Key Board & Mouse Combo Pack 1372 Installation Of Cctv Camera 1373 Dual Core Processor 1374 Cpu Fan 1375 Ps Ii Converter 1376 Wooden Door Painting 1377 Ink Tank Wireless 419 Printer Ink ( Black ) 1378 Ink Tank Wireless 419 Printer Ink ( A. Cyan / B. Megenta / C. Yellow ) 1379 Window Glass Change 1380 Steel Window Repair 1381 Computer Format 1382 Wooden Window Repair 1383 Wooden Window Painting 1384 Wooden Door Frame Change 1385 Wooden Window Frame Change 1386 Wooden Door Making 1387 Wooden Window Making 1388 Printer Tonner Refilling 1389 Cnadle Stand ( A. Large / B. Medium ) 1390 Magazine Stamping 1391 Star Plate For Vehicle 1392 Glow Sign Board Printing On Synthetic Cloth 1393 Steel Almirah ( Small ) 1394 Hiring Of Centre Table 1395 Hiring Of Sofa Set ( A. 3 Seater / B. 1 Seater ) 1396 Air Fryer 1397 Air Fryer 1398 Sprite Polish Of Wooden Table 1399 Sprite Polish Of Wooden Chair 1400 Sprite Polish Of Wooden Almirah 1401 D.S.C. 1402 P.O.E. Box 1403 Optic Fiber 1404 Joint Box 1405 Electric Socket 1406 Pvc Box 4 X 4 1407 Pvc Box 5 X 5 1408 Sprite Polish Of Wooden Window 1409 Fiber Join 1410 Battery 950 1411 Battery 950 1412 Battery 950 1413 Flower Vase 22 ( Bone China )
Contract Date: May 05, 2026 Contract Value : 1.04 Crore
Statutory Bodies & Commissions/Committees No of Bidders 10
West Bengal View Result →
10.
Home Affairs #10976727 Price Bid
SUPPLY OF FORMS & STATIONARY ITEMS/MISCELLANEOUS ARTICLES LIKE FURNITURE AND FIXTURE, COMPUTER PERIPHERALS, R.O. PLANT MATERIALS, DIFFERENT HIRING ITEMS, VARIOUS MACHINERYPARTS.ETC , Pen (Red) , Pen (Blue) , Pen (Black) , Pen (Green) , Refill (Red) , Refill (Blue) , Refill (Black) , Refill (Green) , Ball Pen (Red) , Ball Pen (Blue) , Ball Pen (Black) , Blank C.D. & D.V.D. Plastic Cover , Bodkin With Eye As Per Sample , Bound Register Un-Ruled 150 Sheet As Per Sample , Bound Register Un-Ruled 300 Sheet As Per Sample , Bound Register Un-Ruled 400 Sheet As Per Sample , Bound Register No. 08 Un-Ruled 120 Sheet Conquest Pages , Bound Register No. 08 Ruled 120 Sheet Conquest Pages , Bound Register No. 10 Un- Ruled 150 Sheet Conquest Pages , Bound Register No. 10 Ruled 150 Sheet Conquest Pages , Bound Register No. 04 Un-Ruled Conquest Pages , Bound Register No. 04 Ruled Conquest Pages , Bound Register No. 12 Un- Ruled 200 Sheet Conquest Pages , Calculator (12 Digit)Big Size 112 Steps,Check & Correct Best Quality , Collin Big Size , Compute Paper 80 Column (With Carbon) As Per Sample , Compute Paper 80 Column (Without Carbon) As Per Sample , Correction Pen , Chalk Pencil , 2 Inch Paper Binder Clip Clam , Cellotape Cutter , Channel File , Clip Board File (Plastic) , Borosil With Lid , Duplicating Paper (Size- 21 X 33 Cm) 500 Sheet , Duster Cloth (Size- 54 X 30 Cm) , Duster Cloth (Big Size) , Duster Cloth (Regular) , Duster Wood (Best Quality) , Eraser , Folio Bag For Office Use (Best Quality) , Fax Roll , Gum 300 Ml. Bottle , Gum 700 Ml. Bottle , Gum Tube 50 Ml , Gum Tube 20 Ml , 12 Laser Jet Printer Toner Cartridge 1020 , Paper Hollder Stand , High Light Pen , James Clip , Key Bag Medium Best Quality , Knife Big Size , Marker Pen With Cdm , Marker Pen Permanent , Cd Blank ( R ) , Gala Stamp , Dvd Blank ( R ) , Dvd Blank ( R / W ) , Legal Size Conquest/ Ledger Paper , Note Pad (Itc) , Paper Weight Squire Type Best Quality , Pendrive (16 Gb) , Pendrive (32 Gb) , Pendrive (08 Gb) , Pen Stand Best Quality Medium , Pen Stand Best Quality Big , Pencil , Art Paper , Pencil Carbon (Dfc Size) , Pencil Carbon (Sf Size) , Pilot Pen V5/ V7 (Red) , Pilot Pen V5/ V7 (Blue) , Pilot Pen V5/ V7 (Black) , Pilot Pen V5/ V7 (Green) , Pin Cushion (Metalic) Best Quality , Pin Easy Push Bright Electro Nickel Plated , Plastic Water Jug Best Quality , Paper Memo Holder , Punching Machine , Pointed Ball Pen (Red & Blue) , Paper Holding Binder Clip , Plastic Storage Clip Board , Cheque Book Holder , Sticky Note Pad Large , Sticky Note Pad Small , Refill Gel Pen (Red) , Refill Gel Pen (Blue) , Refill Gel Pen (Black) , Refill Gel Pen (Green) , Tag (Long Size) , Safety Match Box , Classic Block , Permanent Marker Pen For Signature , Scale Wooden06 Inch , Scale Wooden12 Inc , Scissors For Paper Cutting Best Quality Big Size , Sharpner , Sinature Pad (25 Pages With Board Binding) , Sponge With Plastic Case Best Quality , Stamp Pad , Stamp Pad Ink (60Ml) , Stand Candle (Medium) , Stapler Machine (Big 24/6 Size) , Stapler Machine (Small 10 Size) , Date Stamp With Lock , Stapler Pin (Big 24/6 Size) , Stapler Pin (Small 10 Size) , Steel Mnual Call Bell , Self Adhesive Tape 2 Inch Wide , Sketch Pen , Alpin , Table Calling Bell Best Quality , Tag Cotton As Per Sample , Thread Bal (Red) , Thread Bal (White) , Temporary Marker Pen For White Board , Tvs Cartridges Hd755 Ribbon , Tvs Cartridgesprodot Ribbon , Tvs Cartridges Hd745 Ribbon , Tvs 345 Msp Star Ribbon Pronter Cartridges (For 136 Collumn 9/24 Pin Dot Matrix Printers ) , Use And Throw Ball Pen (Blue) , Use And Throw Ball Pen (Black) , Use And Throw Ball Pen (Red) , Use And Throw Pen (Blue) , Use And Throw Pen (Black) , Use And Throw Pen (Red) , Waste Paper Busket (Plastic) Best Quality , White Paper Dfc Size Andhrapradesh -43X69 Cms. 8.6 Kg , White Paper Fc Size , White Board Marker Pen , Wooden Pencil ( Hard-2B ) , Wooden Pencil (Medium Hb ) , Xerox Paper A4 Size Normal Quality , Xerox Paper Legal Size Normal Quality , Colour Flap , Paper Weight Plastic , Feviquick Gum , Fevi Stick Gum , Cello Tape , Steel Scale 12 Inch , Plastic Scale 12 Inch , Stapler Machine Hp 45 Big Size , Photo Paper , Paper Binder Clip Clamp , Camlin White Glue 50 Gm , Bound Register Ruled 600 Sheets Conquest Pages , Bound Register Un-Ruled 600 Sheets Conquest Pages , Luxor V-5 Pen , Bill Register Per Register Containing 200 Sheets With Board Binding Both Side Printing , Bill Register And Page Numbering , Cl Register Containing 100 Sheets Per Book With Page Numbering Covering With Cloth Binding As Per Sample Copy , Challan Form Per 1000 No. Pad Binding 506 Single Side Printing , Contingent Charges Register Per Register Containing 200 Sheets With Cloath Binding Both Side Printing , Contingent Charges Register And Page Numbering , Attendence Register Per Register Containing 56 Sheets With Cloath Binding Both Side Printing , Attendence Register And Page Numbering , Bill Ext. Form Per 1000 Numbers Pad Binding 500 Sheets (Single Side Printing) , Opd Ticket For Hospital Per 1000 Numbers Pad Binding 500 Sheets (Single Side Printing) , Form Of Leave Account Per 1000 Numbers Pad Binding 500 Sheets (Singly Side Printing) , Leave Application Per 1000 Numbers Pad Binding 500 Sheets (Singly Side Printing) , Peon Book Per 1000 Numbers Pad Binding 500 Sheets ( Both Side Printing And Page Numbering) , Master Roll Per Register Containing 200 Sheets With Cloth Binding Both Side Printing , Master Roll Per Register Containing 100 Sheets With Cloth Binding Both Side Printing , Master Roll Per Register Containing 150 Sheets With Cloth Binding Both Side Printing , Master Roll And Page Numbering , Cheque Register Per Register Containing 50 Pages With Boarding As Per Sample (Both Side Printing) , Form Of Nomination For Death Gratuity Per 1000 Number As Per Sample Copy Including Pad Binding 500 Sheets (Singly Side Printing) , Committee Register Per Register Containing 200 Sheets With Board Binding (Both Side Printing) , Admission Of Gpf Form Per 1000 Number As Per Sample Copy Including Pad Binding 500 Sheets (Single Side Printing) , Service Roll Containing 36 Pages Per Book With Cloth Binding As Per Sample With Page Numbering , Form Of Duty Register Containing 500 Pages Per Register With Cloth Binding As Per Sample With Page Numbering , Cc Book Containing 100 Pages Per Book In Dublicate Covering With Cloth Binding And Page Numbering , Distribution Of Arms Form Per 1000 Numbering With Pad Binding 500 Sheets (Single Side Printing) , General Diary Book Per 1000 Numbering With Pad Binding 500 Sheets (Single Side Printing) , El Register Containing 200 Pages Per Book Cobvering With Cloth Binding As Per Sample. , Ext. Acquaintance Roll (Wbf No. 5214)Per 100 Numbers With Pad Binding 500 Copies Single Side Printing , Cover File Double Plastic Coated , Folder File Double Plastic Coated , File Flap Double Plastic Coated , Order Book Containing 100 Pages Per Book Covering With Board Binding Page Numbering And Single Side Printing , Form Of Salary Statement Of Income Tax Per 1000 Numbers As Per Sample Copy Including Pad Binding 500 Copies (Both Side Printing) , Form Of Salary Statement Of The Employees Per 1000 Numbers As Per Sample Copy Including Pad Binding 500 Copies (Both Side Printing) , Form Of Submission Income Tax Statement (Form-16) Per 1000 Numbers As Per Sample Copy Including Pad Binding 500 Copies (Both Side Printing) , Stock Book Of Departmental Containing 1000 Pages Per Register With Cloth Binding As Per Sample. , Tr Form No.-50 Per 1000 Numbers With Pad Binding 500 Copies (Single Side Printing) , Tender Bookcontaining 300 Pages Per Register With Board Binding (Both Side Printing) , Drivers Car Diary Containing 50 Pages Per Diary. , Tr Form No.-21 Per 1000 Numbers As Per Sample Including Pad Binding 500 Sheets (Both Side Printing) , Morning Report (Dg & Igp Cr. Wb) =W= Dig (Ap) Bkpore =W= Dg & Igp (Ap) Wb Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , Morning Report Dig (Ap) Nb Slg =W= Dg & Igp (Ap) Wb =W= Igp (Ap) Nb Slg Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , Morning Report Igp (Ap) Nb Slg =W= Dig (Ap) Nb Slg =W= Dg & Igp (Ap) Wb Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , Morning Report Of Sap 4Th Bn., Kasba, Raiganj, Uttar Dinajpur Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , Ammunition Formper 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , Issue Voucher Form Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , Casualty Form Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , Receipt For Payment W.B.P.M.I.P. Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , B Declaration For Pa Claim Form Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , Declaration Of Family Particulars Per 1000 Numbers With Pad Binding 500 Sheets Single Side Printing. , Firing Registers 100 Pages Board Binding , Allotment Register 150 Pages Board Binding , Order Book 400 Pages Board Binding , Order Book 200 Pages Board Binding , Orderly Room Register 100 Pages Board Binding , Pd Book 100 Pages (Single Side Printing With Duplicate) , Inspection Report Book (Wbf No. 5308 Big Size) 107 Pages Board Binding , Inspection Report Book (Wbf No. 5308 Legal Size) 100 Pages Board Binding , Gpf Register 700 Pages , Cash Book 300 Pages , Rubber Stamp , El Register 300 Pages , El Register 100 Pages , Letter Pad 70 Pages , Leaflet (Both Side) 100 Pcs , Bill Transit Register 100 Pages , Clothing Hand Book Wbp Form No. 5341 (25 Pages) , Receipt For Payment Of Electric Current Charges 100 Pages , Service Bookcontaining 43 Pages Per Book With Cloth Binding As Per Sample With Page Numbering , Form Of Tender 500 Pages , Weekly Pending List (Form No. 203) 100 Pages , Stock Book Of Forms 300 Pages Per Register With Cloth Binding , Stock Book Of Stationary Articles 200 Pages Per Register With Cloth Binding , Received Register Per Register Containing 400 Sheets With Board Binding (Both Side Printing) , Despatch Rigister Per Register Containing 400 Sheets With Board Binding (Both Side Printing) , Register Of Contingent Charges Wb Form No. 2401 ( 324 Pages) , Register Of Contract Contingent Charges Wb Form No. 2402 ( 100 Pages) , Clothing Stock Book 200 Pages , Duty Register Per Register Containing 100 Sheets With Binding Both Side Printing And Page Numbering , Envelope (9.5 X 4.5) Plain Small 100 Pc Per Bundle , Envelope Ordinary (6 X 12) Plain 100 Pc Per Bundle , Envelope (16 X 12) 100 Pc Per Bundle , Envelope Big Size (Cloth) 100 Pc Per Bundle , Envelope A4 Size 100 Pc Per Bundle , Gpf Register 600 Pages (Binding With Cloth Cover) , Gpf Register 400 Pages (Binding With Cloth Cover) , Register Of Proceeding 100 Pages Per Book , Register Of Casualities 100 Pages Per Book , Training Data Form 500 Pages (01 Rim) , Cl Register Containing 200 Sheets Per Book With Page Numbering Covering With Cloth Binding As Per Sample Copy , Ta Bill Register (Formate) 300 Pages , Trodat Stamp , Note Sheet 100 Pages With Sl No. , Pocket Diary , Ta Bill Register (Formate) 200 Pages , Do Letter Pad 70 Pages , 100 Point Register With Binding (300 Pages) , Held Over Register With Binding (200 Pages) , Brown Target Paper , White Binding Paper , Office Diary , Book Binding (Hard Cover Binding) 100 Pages , Book Binding 100 Pages , Book Binding (Cloth Binding) 100 Pages , Book Binding (Normal Binding) 100 Pages , Book Binding (Spiral Binding) 100 Pages , Year Diary (Times) , Executive Diary , Signature Pad , Bill Register200 Sheet , Black & White Printing A-4 Paper , Black & White Printing Legal Paper , Colour Printing A-4 Paper Ban Paper , Pocket Diary , Paper Weight Glass , Normalbook Binding , Hard Cover Book Binding , Cloth Book Binding , Spiral Book Binding , Wall Calender Printing , Ro+Uv + Uf (07 Ltr. Store + 15Ltr./Hr Purify) , Ro+Uv + Uf +Tds (10 Ltr. Store + 15Ltr./Hr Purify) , Water Purifier Machine , Repair Of Water Purifier Machine , Ro Membren , Sediment , Carbon , Booster Pump , Sounoid Valve , Tds Controller , Sensor Float Valve , Ccb , Uv Lamp , Uv Housing , Main Wire , Iron Removal , Uf Membren , Post Carbon , Carbon Of Water Purifier Machine , Candle 10” , Iron Cartridge , Hi Flow Block , P.C.B. , Uv+Uf (6.2 Ltrs.) Dr. Classic , Nxt Uv (8.5 Ltrs.) Dr. Classic , Uv (7 Ltrs.) Dr. Classic , Ro+Uv (6.2 Ltrs.) Kent , Ro+Uv (8.5 Ltrs.) Kent , Ro+Uv (7 Ltrs.) Kent , Ro+Uv (6.2 Ltrs.) Aquaguard , Ro+Uv (8.5 Ltrs.) Aquaguard , Ro+Uv (7 Ltrs.) Aquaguard , Bandage 2½ , Battery 750 , Battery Charger 12 V 2 Amp , Battery Charger 12 V 4 Amp , Battery Charger 12 V 8 Amp , Battery Dry Cell 12Volt. Rechargeable , Battery Dry Cell 6 Volt. Rechargeable , Battery (Medium) , Battery (Pencil) , Bed Switch 6 Amp. , Bell Push Switch (Box Type) , Black Patching Paper , Black Tape (Pvc) , Water Cooler Ss 20/20 With Kent Filter (Ro + Uf + Tds Controller) & Repair , Repair Of Water Cooler Ss 20/40 , Water Cooler Ss 40/80 (Ro + Uf + Tds Controller) & Repair , Water Cooler Ss 40/80 (Ro + Uf + Tds Controller) Repair , Briefcase , Candle (Big Size) 6 Pcs. Pkd. , Carbon Filter , Casserole 1 Ltrs. , Casserole 2.5 Ltrs. , Casserole 4 Ltrs. , Casserole 5 Ltrs. , Casserole 10 Ltrs. , Ceiling Fan 48 (Orient Make) , Ceiling Fan 48 (Crompton Make) , Ceiling Fan 48 (Bajaj Make) , Ceiling Fan 52 (Orient Make) , Ceiling Fan 52 (Crompton Make) , Ceiling Fan 52 (Bajaj Make) , Ceiling Fan Regulator , Ceiling Fan Repairing And Coil Binding , Condenser For Ceiling Fan , Pedestal Fan (Orient Make) , Pedestal Fan (V-Guard Make) , Pedestal Fan (Usha Make) , Pedestal Fan Repairing And Coil Binding , Electronics Regulator For Fan , Portable Rough Pad Rewrteable , Paper And Card Shredder , File Desk Tray , Led Rice Lamp , Rice Lamp , Cup Platemedium Quality (6 Pcs Set) , Cup Plate (Bone China) Good Quality (6 Pcs Set) , Detergent Cake 100 Gm , Detergent Cake 250 Gm , Dinner Plate (Bone China) 6 Pcs. Set , Dinner Set (Bone China) Good Quality , Electric Kettle 1 Ltrs. , Electric Kettle 2 Ltrs. , Electric Kettle 4 Ltrs. , Emergency Light 6 Volt , Extension Cord (Skill) 07 Mtrs. , Extension Cord For Computer (7 Point) , (Ddl) Tube / Container Small , Fevicol (Ddl) Tube / Container Medium , Flask 1 Ltrs. , Flask 2 Ltrs. , Lock ((Navtal), 4 Lvs , Lock ((Navtal) 6 Lvs , Lock ((Navtal), 7 Lvs , Lock ((Navtal), 8 Lvs , Graphic Board , Graphic Board Figure½ , Graphic Board Figure 1 , Graphic Board Letter ½ , Graphic Board Letter 1 , Led Bulb 15 Watt (Philips) , Led Bulb 15 Watt (Havells) , Led Bulb 20 Watt (Philips) , Led Bulb 20 Watt (Havells) , Led Bulb 9 Watt (Philips) , Led Bulb 9 Watt (Havells) , Led Bulb 30 Watt (Philips) , Led Bulb 30 Watt (Havells) , Led Bulb 40 Watt (Philips) , Led Bulb 40 Watt (Havells) , Led Halogen 100 Watt (Philips) , Led Halogen 100 Watt (Havells) , Led Halogen 50 Watt (Philips) , Led Halogen 50 Watt (Havells) , Led Halogen 70 Watt (Philips) , Led Halogen 70 Watt (Havells) , Led Tube Set 20 Wat (Philips) , Led Tube Set 20 Wat (Havells) , Led Tube Set 40 Wat (Philips) , Led Tube Set 40 Wat (Havells) , Led Tube Set 30 Wat (Philips) , Led Tube Set 30 Wat (Havells) , Measuring Tape (Steel) 25 Mtrs. , Measuring Tape (Steel) 75Mtrs. , Measuring Tape (Steel) 100 Mtrs. , Measuring Tape6 , Measuring Tape 20 , Measuring Tape 50 , Measuring Tape 100 , Metal Bulb 250 Watt , Metal Bulb 500 Watt , Metal Choke 250 Watt , Metal Choke 500 Watt , Metal Lamp Complete Set 250 Watt , Metal Lamp Complete Set 500 Watt , Microphone , Microphone Cordless , Microphone Transistor (Ahuja) 80 Watt , Microphone Transistor 100 Watt , Microphone Transistor 120 Watt , Mike Set Unit And Horn , Sound Box50 Watt , Sound Box 80 Watt , Sound Box 100 Watt , Sound Box 120 Watt , Microphone Stand , Mixer Grinder 750W , Mixer Grinder 1200W , Ors 15 Mg Pouch , Ors 20 Mg Pouch , Ors 25 Mg Pouch , Ors 50 Mg Pouch , Ors- L (Pouch) , Phenyl , Pvc Tape (Big Roll) , Revibe (Big Size) , Room Freshener 375 Ml. , Steiner 200 Ml. Bot. , Starter For Ac 18-25 Amp , Starter For Ac 25 Amp (2 Ton) , Starter For Ac 25 Amp 2 Ton , Ac Machine Copper Pipe / Per Mtr. , Stop Watch (Digital) , Dslr Camera (Nikon) , Dslr Camera (Canon) , Thermo Flask 1 Ltrs (Eagle) , Thermo Flask 1 Ltrs (Milton) , Thermo Flask 2 Ltrs (Eagle) , Thermo Flask 2 Ltrs (Milton) , Tiffin Carrier Four Container (Steel) , Wall Clock (Digital) , Wall Clock , Wall Machine , Wall Clock Repair , Weight Machine (For Articles) 5 Kg Capacity With Units , Weight Machine Digital , Zeoline 50 Ml Bot. , Zeoline 100 Ml Bot. , Zeoline 200 Ml Bot. , Name Plate Brass Made (Per Letter) , Name Plate Board Plastic , Name Plate Board Wooden , Name Plate(Embroidery)/ Per Letter , Succession Board Fiber , Succession Board Wood , Succession Board Printing , Angle Drill , Flex/ Banner Per Sqft. , Basket Plastic , Double Bed Cover (Normal Quality) , Double Bed Cover (Best Quality) , Single Bed Cover (Best Quality) , Single Bed Sheet (Normal Quality) , Black Board Small / Per Sqft. , Black Board Medium / Per Sqft. , Black Board Big / Per Sqft. , Black Board Stand (Iron) , White Board Small / Per Sqft. , White Board Medium / Per Sqft. , White Board Big / Per Sqft. , Black Board Stand (Wooden ) , Black Fluorescent Tape 1 , Black Target Paper / Per Pc. , Blinker (Solar) , Bone Dust / Per Kg. , Bowl Set (Bone China) , By-Cycle Rim , By-Cycle Tube (Nylon) , By-Cycle Bell , By-Cycle Sit , By-Cycle Pumper , By-Cycle , Coffee Cup Small / Per Set , Coffee Cup Medium / Per Set , Coffee Glass , Coffee Mug , Cotton 100 Gm Pkd. , Cotton Mattress , Dustbin (Use Me) 14G.I. Sheet , Dustbin (Use Me) 18 G.I. Sheet , Dustbin Plastic (Leg Press) Big , Dustbin Plastic (Leg Press) Medium , Dustbin Plastic (Leg Press) Small , Duster Cloth , Fiber Glass 4 Mm Standard / Per Mtr. , Fiber Plate Small , Fiber Plate Medium , Fiber Plate Large , Fiber Sheet , Fiber Tray , Fire Bucket 12 , Fire Bucket 18 , Fire Extinguisher Refilling (2 Kg.) , Fire Extinguisher Refilling (5 Kg.) , Fire Extinguisher Refilling (9 Kg.) , First Aid Box (Medium Size) With All Necessary Equipment And Medicine , Flower Vase 22 Brass , Folding Chair (Steel) , Folding Cot (Nylon Fita) , Folding Table (Moulded) , Gala (Seal Wax) , Glass 3 Cell Torch , Glass Bowl , Glass Lid (4 Pcs. Set/6 Pcs. Set/8 Pcs. Set) , Glow Sign Board Complete Fitting (Per Sqft.) , Hand Sanitiser Dispensing Machine With Temperature Detection , Hand Towel (Standard Size) , Height Measuring Stand (Metal) , Hurricane Lantern (Local Made ) , Infrared Digital Thermometer , Iron Door Frame /Per Kg. , Iron Door Frame With Palla / Per Kg. , Iron Grill / Per Kg. , Iron Made Arms Rack / Per Kg. , Jurricane (Pvc) 5 Ltrs. , Letter Punch (A To Z) Brass & Steel , Liquid Measuring Equipment , Magnifying Glass , Markin Cloth Per Mtr. , Mask ( N-95) , Mask (Cloth) , Mask (Surgical) , Mirror Small / Per Sqft. , Mirror Medium / Per Sqft. , Mirror Long / Per Sqft. , Moulded Centre Table , Moulded Chair With Cushion , Moulded Chair With Handle , Moulded Chair Without Handle , National Flag , Pad Lock 5 Lvr. , Pad Lock 6 Lvr. , Pad Lock 7 Lvr. , Pad Lock 8 Lvr. , Paper Weight (Marble) , Paper Weight (Plastic) , Ply Board (Commercial) / Per Sqft. , Ply Board (Kit) , Wooden Furniture (Sal) Per Sqft. , Wooden Furniture (Sisu) Per Sqft. , Wooden Furniture (Akash Moni) Per Sqft. , Scissors For First Aid Box Small , Scissors For First Aid Box Medium , Scissors For First Aid Box Large , Scissors (Tailors) , Sealing Punch Machine , Side Pillow , Side Pillow Cover , Head Pillow , Head Pillow With Cover , Steel Scale 12 , Spoon Set (V.I.P.Steel) / Per Set , Spoon Set Plastic Handle /Per Set , Steel Spoon (Big) Vip / Per Set , Steel Fork Good Quality Small / Per Set , Steel Fork Good Quality Big / Per Set , Steel Spoon (Small) Vip / Per Set , Steel Tray , Sutli / Per Kg. , Tea + Biscuit , Tea Container 05 Ltrs. , Tea Container 10 Ltrs. , Tea Container 15 Ltrs. , Tea Set (Bone China) Good Quality , Tiles (Grade - 1) , Tissu Paper , Tissu Paper For Toilet , Towelgood Quality Standard Size , Towelgood Quality 24 (Suparior Quality) , Towelgood Quality 24 (Good Quality) , Towelgood Quality 24 (Best Quality) , Towelgood Quality 72 (Suparior Quality) , Towelgood Quality 72(Good Quality) , Towelgood Quality 72(Best Quality) , Transparent Table Cloth Per Mtr. , Umbrella Big Size , Umbrella Standard Size , Wall Mounted Digital Thermometer , Water Glass 06 Pcs. Set (Best Quality) , Water Glass 06 Pcs. Set (Normal Quality) , Water Bottle (1 Ltr.) , Water Bottle (500 Ml.) , Water Bottle (250 Ml.) , White Table Cloth (Cotton) Per Mtr. , Furniture (Steel) / Per Sqft. , Furniture (Iron) / Per Sqft. , Wrist Band , Water Drum (20 Ltrs) , Tarpaulin Covering / Per Sqft. , Duster For White Board , Hiring Charges Of Ceilling Fan With Fitting / Per Fan, Per Day , Hiring Charges Of Pedestal Fan With Fitting / Per Fan, Per Day , Hiring Charges Of Jhar Fan With Fitting (28) Dia. / Per Set, Per Day , Hiring Charges Of Tulu Pumpwith Fittings. / Per Pump, Per Day , Hiring Charges Of Tube Light / Per Tube Light, Per Day , Hiring Charges Of Metal Light / Per Metal / Per Day , Tv Hairing / Per Tv, Per Day , Hairing Chair / Per Chair, Per Day , Hiring Executive Chair / Per Chair, Per Day , Hiring Table / Per Table, Per Day , Hiring Cooler Machine / Per Cooler, Per Day , Hiring Heater / Per Heater, Per Day , Ac Machine Hiring / Per Ac, Per Day , Boil Egg (01 Pc.) , Cake (01 Pc.) , Banana (01 Pcs.) , Sweets-(01 Pc.) , Snacks , Vip Chair Hiring / Per Chair, Per Day , Computer Table (Single) , Computer Table (Dubble) , Iron Cot Repairing Including Painting , Ply Green Panelling In Wall Per Sqft. , Ply Normal Panelling In Wall Per Sqft. , Falls Ceiling With Fitting And Painting Per Sqft. , Temporary Wooden Furniture Work Per Sqft. , Floor With Verified Tiles With Fitting Per Sqft. , Wooden Door With Brass Lock And Handle Per Sqft. , Aluminium Frame Fitted With Glass Door (5 X 2) , Aluminium Frame Fitted With Glass Window(4 X 3) For Each Window , Wooden Book Self (6 X 3) (Good Quality Wood) Per Sqft. , Glass For Centre Table Per Sqft. , Ply Wardrobes (Normal Quality)/ Per Sqft. , Ply Wardrobes (Best Quality)/ Per Sqft. , Wooden Wardrobes (Normal Quality Wood)/ Per Sqft. , Wooden Wardrobes (Best Quality Wood)/ Per Sqft. , To Make New Ceiling By Ply Board Without Frame Works With Labour Charges Per Sqft. , Wooden Door Repair Per Sqft. , Floor Mat , Sanitizer , Oxygen Cylinder 14 Ltrs , C.C.T.V. Camera , 8 Ch Nvr , 16 Ch Nvr , 32 Ch Nvr , Ip 4Mp Bullet , 16Ch K2 Accusens Network Video Corder (Nvr), 2 Sata Upto 8Mp Supproted , Cat -6 Lan Cable / Per Mtr. , Ip Network 50Mtr Bullet Camera , Ip Network 4Mp Accusen Bullet Camera , Ip Network 4Mp Accusen Dome Camera , Midea Converter (Mc) , Poe 4 Port , Poe 8 Port , Ip 4Mp Dome , Wiring And Installation Charge / Per Cctv Camera , Dvr Lock Box , C.C.T.V. Cable & Wire / Per Camera, Per Mtr. , Coaxialcable / Per Mtr. , C.C.T.V. Connector , Digital Video Recorder , Dc Power Cable / Per Mtr. , Video Baluns , Security Camera Microphone , C.C.T.V. Video Multiplexers , Wireless Video Transmitters , Security Camera Lens , Siamese Cable / Per Mtr. , Patch Cord , Installation Of Cctv Camera / Per Camera , 4 Port , Adapter (12 V 2 Amp) , Adapter (05 V 2 Amp) , Optic Fiber , Joint Box , Electric Socket , Pvc Box 4 X 4 , Pvc Box 5 X 5 , P.O.E. Box , Telephone Receiver (With Truecaller) , Telephone Receiver (Without Truecaller) , Telephone Receiver Color Id (Normal Quality) , Telephone Receiver Color Id (Best Quality) , Set Top Box-Digital/Hd With Recoding-1 Yrs. Package With Full Channals , Dish Tv Monthly Recharge , Jio Fiber Monthly Recharge , Mobile Phone-Android With Gps Facility With Camera , Steel Almirah (Big Size) 78”X36”X22” , Steel Almirah (Medium Size) 60”X36”X20” , Book Self (78”X36”X22”) Wooden / Per Sqft , Book Self (78”X36”X22”) Steel / Per Sqft. , Filing Cabinet (60”X36”X20”) , Steel Rack (45X61X22) / Per Sqft. , Steel Table With Glass Top (Six Sitter) , Steel Table With Glass Top (Four Sitter) , Executive Table Wooden (Segun Wood)- Wood Per Sqft. , Executive Table Wooden (Akashmoni Wood)- Wood Per Sqft. , Executive Table Wooden (Grass Board)- Per Sqft. , Wooden Table (Segun Wood) Per Sqft. , Wooden Table (Normal Wood) Per Sqft. , Wooden Rack (Best Quality Wood) Per Sqft. , Wooden Rack (Normal Quality Wood) Per Sqft. , Wooden Chair With Arm (Normal Quality Wood) Per Sqft. , Wooden Chair With Arm (Best Quality Wood) Per Sqft. , Wooden Normal Chair (Best Quality Wood) , Wooden Normal Chair (Normal Quality Wood) , Steel Chair , Plastic Chair With Arm , Plastic Chair Without Arm , Executive Chair (Big Size) , Executive Chair (Small Size) , Revolving Chair , Computer Chair , Computer Chair (Without Arm) , Fiber Chair (Without Arm) , Fiber Chair With Kushan (With Arm) , Fiber Table , Wooden Tool / Per Sqft. , Wooden Back Bench (Sisu Wood) Per Sqft. , Wooden Back Bench (Good Quality Wood) Per Sqft. , Fiber Tool , Table Glass (5 Mm/ 8Mm) Per Squre Fit , Wooden Rifle Rack 10 Capacity With Single (Sal Wood) Per Sqft. , Wooden Rifle Rack 10 Capacity With Single (Sisu Wood) Per Sqft. , Wooden Rifle Rack 10 Capacity With Double (Sal Wood) Per Sqft. , Wooden Rifle Rack 10 Capacity With Double (Sisu Wood) Per Sqft. , Wooden Rifle Rack 20 Capacity With Single (Sal Wood) Per Sqft. , Wooden Rifle Rack 20 Capacity With Single (Sisu Wood) Per Sqft. , Wooden Rifle Rack 20 Capacity With Double (Sal Wood) Per Sqft. , Wooden Rifle Rack 20 Capacity With Double (Sisu Wood) Per Sqft. , Office Chair Plastic , Wooden Dining Table (Sal Wood) Per Sqft. , Wooden Dining Table (Sisu Wood) Per Sqft. , Wooden Dining Bench (Sal Wood) Per Sqft. , Wooden Dining Bench (Sisu Wood) Per Sqft. , Notice Board With Glass Per Sqft. , Steel Bench Per Sqft. , Display Board Per Sqft. , Map Board Per Sqft. , Door Mats , Wall Cabinet , Side Cabinet , Hang Mirror / Per Sqft. , Door & Window Curtain Cloth With All Accessories With Fittings & Fixing (Best Quality) Per Mtr. , Door & Window Curtain Cloth With All Accessories With Fittings & Fixing (Normal Quality) Per Mtr. , Wooden Cot (Segun Wood) Per Sqft. , Wooden Cot (Akashmoni Wood) Per Sqft. , Dressing Table (Segun Wood) Per Sqft. , Dressing Table (Akashmoni Wood) Per Sqft. , Almirah Lock Repairing , Photo Binding With Glass / Per Sqft. , Cup & Plate (Laopala Made) , Cup & Plate (Normal Quality) , Desk Calendar , Desk Calendar Stand , Drinking Glass (Normal Quality) , Drinking Glass (Best Quality) , Punching Machine Big , Punching Machine Mideum , Sealing Wax , Table Tray , Table Top , Colour Photo Print (4/6) , Colour Photo Print (5/7) , Colour Photo Print (8/10) , Colour Photo Print (8/12) , Iron Trunk / Per Sqft. , Hipping Hammer , Serch Light / Dragon Light Cherger , Sandwich Maker (Wipro) , Sandwich Maker (Prestige) , Toaster (Philips) , Toaster (Kent) , Dinner Set (Borosil) , Dinner Set (Cello) , Dinner Set (La Opala) , Wall Hanger , Hot Pot Bowl (Milton) , Hot Pot Bowl (Cello) , Table Mat , Exhaust Fan (Crompton) , Exhaust Fan (Havells) , Exhaust Fan (Bajaj) , Exhaust Fan Repairing , Desk Organiser , Tv 32 (Sony) , Tv 32 (Lg) , Tv 32 (Mi) , Tv 43 (Sony) , Tv 43(Lg) , Tv 43 (Mi) , Tv 55 (Sony) , Tv 55 (Lg) , Tv 55 (Mi) , Tv 60 (Sony) , Tv 60 (Lg) , Tv 60 (Mi) , Mobile Charger , Furniture Painting / Sqft. , Green Tea (Per 100 Gm) , Coffee (Per 100 Gm.) , Darjelling Tea (Per 100 Gm.) , Biscuit (Per Pkt.) , Sugar Cube (Per Pkt.) , Rice (Tulai Panji) / Per Kg. , Rice (Sova) Per Kg. , Dal Per Kg. , Fish Per Pc. , Vaja / Per Pkt. , Chatni / Per Pkt. , Sweets / Per Pc. , Books , Bicycle , Broad Band Connection + Installation + Monthly Package , Wooden High Bench (Sal Wood) Per Sqft. , Wooden High Bench (Sisu Wood) Per Sqft. , Wooden High Bench (Normal Wood) Per Sqft. , Wooden Low Bench (Sal Wood) Per Sqft. , Wooden Low Bench (Sisu Wood) Per Sqft. , Wooden Low Bench (Normal Wood) Per Sqft. , Ash Tray , Microtek Intel Pure Sine Wave 1625 W E2+ Inverter With 150 Amp It 500(Exide) Battery & Trolley , Microtek Intel Pure Sine Wave 1625 W E2 Repairing , Microtek 1825 E2 Sine Wave Inverter With 02 No. 150 Amp It 500(Exide) Battery & Trolley , Microtek 1825 E2 Sine Wave Inverterrepairing , Microtek 1225 E2 Inverter With 01 No. 150 Amp It 500(Exide) Battery & Trolley , Microtek 1225 E2 Inverter Repairing , Invatubllar Battery 150 Amp It 500(Exide) , Microtek E2 + 1625 Va Sine Wave Ups Fy 1813 Inverter Repairing , Inverter Trolley , Gastifier Stove , Repair Of Gastifier Stove , Chapatti Vati Machine , Repair Of Chapatti Vati Machine , Wooden Table & Rack Per Sqft. , Ornate Chair , Jute Sack , Target Paper , Figure 11 , Furniture Repairing With Painting (Per Sqft.) , Sprite Polish & Colour Of Wooden Door (Per Sqft.) , Sprite Polish & Colour Of Wooden Window (Per Sqft.) , Sprite Polish & Colour Of Wooden Furniture (Per Sqft.) , Polishing & Colouring Of Steel Furniture (Per Sqft.) , Sprite Polishing & Colouring Of Wooden Furniture (Per Sqft.) , Wall Calendar Printing , Sofa Set One Sitter , Sofa Set Three Sitter , Centre Table Wooden With Glass Fitting Per Sqft. , Centre Table , Kitchen Chimney (Kutchina) , Kitchen Chimney (Jaypan) , Microwave (Whirlpool) , Microwave (Lg) , Micro Plate/ Bowl , Refrigerator (Haier) , Refrigerator (Lg) , Refrigerator (Whirlpool) , Refrigerator Servicing And Gas Filling , Refrigerator Compresser Change , Hooter , Steel Buffet , Buffet Gel , Iron Floor And Desk Stand , Pbx Machine , Table Calendar , Metal Key Chain , Tissue Paper Holder , Juicer (Bajaj) , Juicer (Havells) , Video Camera Sony (Best Quality) , Video Camera Sony (Normal Quality) , Breath Analyzer , Hand Towel (Superior Quality) , Hand Towel (Best Quality) , Hand Towel (Good Quality) , Saxophone , Clarinet , Trumpet , Euphonium , Euphonium Spring , Big Drum , Side Drum , Side Drum Synthetic , Bugler , Bugler Mouth Piece , Trumpet Mouth Piece , Euphonium Mouth Piece , Bugle Siling , Trumpet Spring , Big Drum Synthetic , Big Drum Biter , Big Drum Siling , Side Drum Stick , Side Drum Siling , Clarinet Bob , Saxophone Bob , Pipe Rid , Chanter Rid , Leather , Wax / Per Kg. , Big Drum Belt , Tener Drum Biter , Tener Drum Belt , Pipe Don , Lerniar , Solder Cover , Batch , Belt , Shall , Beret Cap , Crown , Pipe Chanter , Practice Chanter , Saxophone Repair , Clarinet Repair , Trumpet Repair , Euphonium Repair , Dress For Brass Band , Dress For Pipe Band , Saxophone Rid , Saxophone Mouth Pice , Clarinet Mouth Pice , Side Drum Spring , Tie , Leather Cover , Flue Pipe , Pipe Cord , Pipe Master Stick , Brass Master Stick , Officer’S Cap , Saxophone Box , Saxophone Neck Strip , Clarinet Box , Trumpet Box , Cloth For Coat/ Summer Coat Per Mtr. , Cloth For Pant Per Mtr. , Pipe Lather Cover , Pipe Ribbon , Pipe Flag , Pipe Mouth Piece , Clarinet Notation Stand , Trumpet Notation Stand , Saxophone Notation Stand , Music Manuscript Book , Shirish Paper / Per Pc. , Activated Carbon , Gravels Stone , Mno2 , Treated Sand , Anthracite , Clorin , Anti Scelent Chemicals , Add Minerals , Sodium Bicarbonate , 5 Micron Jambu Filter , Dosing Pump Pipe / Per Mtr. , Back Wash Valve , Multiport Valve , Uv System , Ro Membren (250Lph) , Chemical For Washing , Citric Acid , High Pressure Pump (Cri) , Raw Water Pump , Pressure Metre , Flow Metre , Vessel , Lesser Pipe , Jambu Filter , Jambu Cartage , Dosing Pump , Electric Panel , 1 Hp Raw Pump , Pipe Fitting , Meneral Powder , Silex , Condenser Ac Machine , Fan For Ac Machine , A.C Machine Servicing And Gas Filling , Copper Pipe (A.C. Machine) / Per Mtr. , Circuit Change (A.C. Machine) , Sensor (A.C. Machine) , Jona Dohar Double (Best Quality) , Jona Dohar Double (Normal Quality) , Jona Dohar Single (Best Quality) , Jona Dohar Single (Normal Quality) , Small Hand Towel ( Superior Quality) , Small Hand Towel (Best Quality) , Small Hand Towel (Good Quality) , Blanket Double (Best Quality) , Blanket Double (Nomal Quality) , Blanket Single (Best Quality) , Blanket Single (Nomal Quality) , Mattress (6’X7’) , Mattress (5’X6’) , Mattress (4’X6’) , Bracket For Curtain , Still Pipe For Curtain /Per Mtr. , Rent Of Cctv Camera Per Camera Per Day , Vacuum Cleaner (Philips) , Vacuum Cleaner (Eureka) , Tea Table (Steel) , Wire Clip / Per Set , Elastic / Per Mtr. , Sofa Cover , Switch 6 Amp , Hanger , Table Lamp , Small Towel (For Pillow) , Microwave Oven , Geyser (10 Ltr.) , Geyser (5 Ltr.) , Roti Maker Machine , Roti Maker Machine Repairing , Big Size Towel (Superior Quality) , Big Size Towel (Best Quality) , Big Size Towel (Good Quality) , Distilled Water / Per Ltr. , Dress Cord , 12 Mm. Ply Furniture With Sunmica With Fitting And Fixing Per Sqft. , 18 Mm. Ply Furniture With Sunmica With Fitting And Fixing Per Sqft. , 12 Mm. Ply Furniture With Sunmica With Colouring Per Sqft. , 18 Mm. Ply Furniture With Sunmica With Colouring Per Sqft. , Moulded Dining Table , Table Calendar Printing , Wall Calendar , Table Calendar , Window Glass Change Per Sqft. , Steel Window Repair Ser Sqft. , Wooden Window Repair Normal Wood Per Sqft. , Wooden Windowa Repairing With Painting Best Wood Per Sqft. , Wooden Door Frame Change Best Wood Per Sqft. , Wooden Window Frame Change Normal Wood Per Sqft. , Wooden Door Making Best Wood (Segun) Per Sqft. , Wooden Door Making Best Wood (Normal Wood) Per Sqft. , Wooden Window Making (Segun) Per Sqft. , Wooden Window Making (Normal Wood) Per Sqft. , Cnadle Stand (A. Large/ B. Medium) , Magazine Stamping , Star Plate For Vehicle (Per Star) , Glow Sign Board Printing On Synthetic Cloth (Per Sqft.) , Steel Almirah (Small) , Hiring Of Centre Table , Hiring Of Sofa Set (A. 3 Seater/ B. 1 Seater) Per Day , Air Fryer (Best Company Best Model) , Air Fryer (Good Company Good Model) , D.S.C. , Normal Painting Of Wooden Window Per Sqft. , Normal Painting Of Wooden Door Per Sqft. , Fiber Join , Exide Invatubular It950, 12V 260Ah Tall Tubular Inverter Battery , Flower Vase 22 (Bone China) , Wall Mount Fan (Orient) , Wall Mount Fan (Havells) , Wall Mount Fan (Crompton) , Tooth Pest (Good Quality) , Tooth Pest (Best Quality) , Tooth Brush (Good Quality) , Tooth Brush (Best Quality) , Tub (Plastic) , Mug (Plastic) , Hair Oil (Best Quality) , Hair Oil (Good Quality) , Mustered Oil Per Kg. , Bath Room Seeper (Best Quality) , Water Carrier Tin , Wooden Colour (Good Quality) Per Ltr. , Wooden Colour (Best Quality) Per Ltr. , Woodn Primer Per Ltr. , Metal Colour (Good Quality) Per Ltr. , Metal Colour (Best Quality) Per Ltr. , Metal Primer Per Ltr. , Weather Coat (Good Quality) Per Ltr. , Weather Coat (Best Quality) Per Ltr. , Wall Primer Per Ltr. , Wall Putti Per Kg. , Cement (Good Quality) Per Bag , Cement (Best Quality) Per Bag , Whight Cement Per Bag , Sand Per Cft. (Balason) , Stone Chip 1/2 Per Cft (Muraroi) , Stone Chip 1/2 Per Cft. , Stone Chip 3/4 Per Cft , Stone Chip 5/8 Per Cft , Colouring Tin (Tata Make) Per Pc. , Tarkata Per Kg. , Coconut Rope Per Kg. , Bamboo / Per Pc. , Iron Rod 6Mm (Tata) / Per Pc. , Iron Rod 8Mm (Tata) / Per Pc. , Iron Rod 10Mm (Tata) / Per Pc. , Iron Rod 12Mm (Tata) / Per Pc. , Iron Rod 16Mm (Tata) / Per Pc. , Fax Machine Repair , Iron Rod 25Mm (Tata) / Per Pc. , Treadmill (Electric) , Treadmill (Non-Electric) , Treadmill Repairing / Servicing , Printer Tonner Rifilling , Printer Tonner Rifilling With Drum Change , Xerox Machine Repairing , Paper /File Maintenance Software With 2 Years Maintenance , Typing Software With 2 Years Mainantence , Fax Machine Repair , Fax Machine , Xerox Machine Tonner , Xerox Machine Tonner (Canon- Image Runner 2004) , Computer Items , 1Kva Online Microtek Ups 24Vdc-Ib , 3.5 Audio Aux Cable Ranz 1.5 M , 3.5 Male Female Cable Kensonic 1.5 M , 3D Sticker For Laptop , 3 In 1 Type-C Usb Hub , 4G Router Lapcare 4 Antena (W123) Lkio4a8341 , 8 In 1 Type-C Usb Hub , Acer Monitor 22 Fhd Non Ips , Adapter 5V 2A Ranz , Adapter Acer 65W 19V 3.42 Amp , Adapter Dvm 19V-0.84Amp , Adapter Dvm 24V 3A , Adapter Lapcare 12V 1A 2.1 , Adapter Lapcare 12V 2A 2In1 , Adapter Lapcare 12V 5Amp (8368) , Adapter Laptop Acer 45W , Adapter Laptop Acer 45W 19V Org , Adapter Laptop Asus 40W , Adapter Laptop Asus 45W , Adapter Laptop Asus 65W , Adapter Laptop Dell 180W (47Rw6/2N6c5) , Adapter Laptop Dell 45W , Adapter Laptop Dell 65W , Adapter Laptop Dell 90W 5Gt3k , Adapter Laptop Frontech Lap-0003 65W , Adapter Laptop Hp 65W 4.5Mm , Adapter Laptop Hp 65W 7.4Mm , Adapter Laptop Lapcare , Adapter Laptop Lapcare 65W/61W Type-C , Adapter Laptop Lapcare 90W - 19V , Adapter Laptop Lapcare Asus 19V. 45W , Adapter Laptop Lapcare For Asus 45W , Adapter Laptop Lapcare For Asus Mini Usb , Adapter Laptop Lapcare For Dell 45W , Adapter Laptop Lapcare For Dell 65W , Adapter Laptop Lapcare For Hp 65W , Adapter Laptop Lapcare For Hp 90W , Adapter Laptop Lapcare For Lenovo 45W , Adapter Laptop Lapcare For Lenovo 65W , Adapter Laptop Lapcare For Toshiba , Adapter Laptop Lapcare Hp 65W , Adapter Laptop Lapcare Toshiba 65W , Adapter Laptop Lapcare Universal 65W Type-C , Adapter Laptop Lapgrade , Adapter Laptop Lenovo 45W , Adapter Laptop Lenovo 65W , Adapter Laptop Lenovo 90W Org Big Pin , Adapter Original Ngxgold , Adapter Ranz 12V 3A 36W , Adapter Ranz 14V 2.14A 30W , Adapter Ranz 19V 2.1A 40W , Adapter Ranz 9V 1A 2.1 , Adapter Zentek 5V 1Amp 2In1 , Antivirus Bitdefender Total Security 1Pc 2Y , Antivirus Escan 1Pc 1Y , Antivirus K7 Total Security 1Pc 1Y , Antivirus Quickheal I/S 10Pc 1Y , Antivirus Quickheal I/S 1Pc 1Y , Antivirus Quickheal I/S 3Pc 3Y , Antivirus Quickheal I/S Upg 1Pc 3Y , Antivirus Quickheal Pro 10Pc 1Y , Antivirus Quickheal Pro 1Pc 1Y , Antivirus Quickheal Pro 1Pc 3Y , Antivirus Quickheal Pro 2Pc 3Y , Antivirus Quickheal Pro 3Pc 1Y , Antivirus Quickheal Pro Upgrade 1Pc 1Y , Antivirus Quickheal Pro Upgrade 1Pc 3Y , Antivirus Quickheal Total Security 10Pc 1Y , Antivirus Quickheal Total Security 1Pc 1Y , Antivirus Quickheal Total Security 1Pc 3Y , Antivirus Quickheal Total Security 2Pc 1Y , Antivirus Quickheal Total Security 2Pc 3Y , Antivirus Quickheal Total Security 3Pc 1Y , Antivirus Quick Heal Total Security 3Pc 3Y , Antivirus Quickheal Total Security 5Pc 1Y , Antivirus Quickheal Total Security 5Pc 3Y , Antivirus Quickheal Total Security Upgrade 1Pc 1Y , Antivirus Quickheal Total Security Upgrade 1Pc 3Y , Antivirus Quickheal T/S 10Pc 3 Years , Antivirus Quickheal T/S Festival 1Pc 1Y , Antivirus Wardwiz Essential 1Pc 1Y , Anycast M9 Plus , Asus All-In-One A3202wba-Wpb002w , Asus Rog Ally Handheld Gaming Console Rc71l-Nh001w , Asus Rog Strixg614jv-N3474ws , Asus Vivobook 14 Flip Tp3402vab-Lz541ws , Asus Vivo Book X1500ka-Ej021w , Audio Converter 2In1 , Audio Receiver Frontech Jil-0824 , Audio Receiver Iball , Av To Hdmi , Backpack Acer Mrp1999 , Backpack Asus Ap1600 , Backpack Asus Ap4600 , Backpack Asus Bp1504 , Backpack Asus Mrp2999 , Backpack Asus Tuf Bpvp5700 , Backpack Dell Mrp1999 , Backpack Dell Mrp2999 , Backpack Hp Mrp 1499 , Backpack Hp Mrp1999 , Backpack Hp Mrp2399 , Backpack Hp Prime , Backpack Lenovo Legion Mrp7490 , Backpack Lenovo Mrp1999 , Backpack Lenovo Mrp2999 , Backpack Police , Backpack Toshiba , Barcode Roll 105Mmx300m , Barcode Scanner Tvs Bs-C101 Star , Barcode Scanner Tvs Bs-C103g , Barcode Scanner Tvs Bs-L150s Wl , Battery 2032 Dura Cell , Battery Laptop Acer As16a5k-4S1p , Battery Laptop Apple A2337 , Battery Laptop Asus Original , Battery Laptop Avita Oem , Battery Laptop Dell Original , Battery Laptop Hp Hs04 , Battery Laptop Hp Ht03xl , Battery Laptop Hp Original , Battery Laptop Lapcare Dell 3451 (6120) , Battery Laptop Lapcare Dv2000 , Battery Laptop Lapcare E6400 (2156) , Battery Laptop Lapcare Hp 4320S/4520S (2622) , Battery Laptop Lapcare Hp 6700B/6500B , Battery Laptop Lapcare Hp Cq42 (2101) , Battery Laptop Lapcare Hp Vi04 (5313) , Battery Laptop Lapcare Hs04 , Battery Laptop Lapcare Ht03xl , Battery Laptop Lapcare Jc04 , Battery Laptop Lapcare L16l2pb2 , Battery Laptop Lapcare L600 (3205) , Battery Laptop Lapcare Lenovo G430/G530 , Battery Laptop Lapcare Oa04 , Battery Laptop Lapcare Oa04 (5115) , Battery Laptop Lapgrade For Hp Cq32/42/62 3116 , Battery Laptop Lapgrade Lenovo G400/G500 4397 , Battery Laptop Lapgrade Lenovo G460 , Battery Laptop Lapgrade Lenovo Y480 , Battery Laptop Lenovo Original X240 , Battery Lithium Mb 2032 , Battery Ups Frontech , Battery Ups Intex , Battery Ups Microtek , Bluetooth Speaker Coco Sports Billy , Bluetooth Speaker Coco Sports Rockey Evs01 , Bluetooth Speaker Coco Sports Sandy , Boat Bassheads 900 Pro , Boat Rockerz 370 Pro , Boat Rockerz 400 Pro , Boat Rockerz 425 , Boat Rockerz 450 , Boat Rockerz 450 Pro , Boat Rockerz 460 , Boat Rockerz 550 , Boat Rockerz 650 Dc Crusade , Boya Wired Condenser Karaoke Mic , Cabinet Clarion Jm-Kraft Wh , Cabinet Coco Sports Gaming Rgb Nova 110 Black , Cabinet Coco Sports Gaming Rgb Nova 220 White , Cabinet Coco Sports Rampage Elite Black , Cabinet Coco Sports Rampage Elite White , Cabinet Cooler Master 310C , Cabinet Frontech Arcadia (G) , Cabinet Frontech Candy (G) , Cabinet Frontech Case And (G) , Cabinet Frontech Fiera , Cabinet Frontech Ft-4285 Xylo , Cabinet Frontech Ft-4285 Xylo White , Cabinet Frontech Inferno (G) , Cabinet Frontech Mystic (G) , Cabinet Frontech Nico , Cabinet Frontech Phantom White (G) , Cabinet Frontech Rift (G) , Cabinet Frontech Snowy (G) , Cabinet Frontech Tower , Cabinet With Smps Intex P4 It-1710 , Cabinet Zebronics Gaming Iceberg (White) , Cabinet Zebronics Gaming Invicta , Cabinet Zebronics Gaming Iron Side , Cable Hdmi 5M , Cable Hdmi To Dvi 1.5M Ranz , Cable Hdmi To Vga 1.8M Ranz , Cable Mantra Ranz , Cable Mantra Ranz Premium , Cable Morpho Ranz , Cable Morpho Ranz Premium , Cable Ranz Type C Totype C , Cable Sata Y Spliter , Cable Type-C To Hdmi 1.8 Mtr. , Cable Type-C Usb Mi Black , Camera To-Link Wifi/Tilt Tc70 Tapo , Canon G2020 Maintanance Box , Car Charger 150W Lapcare , Card Reader Multiranz , Cartridge Epson Fx890 , Cartridge Epson Plq20 Original , Cartridge Spink Lq-310 , Cartridge Tvs Ribbon 80C , Charger With Cable Mi 2A Fast , Chasis Fan Tag 120Mm , Cleaning Kit Ranz Rz-1016 , Cleaning Kit Smart Pro Sp-Lc-001 , Comforter Ackross Floralwhisper Double , Computer Tool Kit 6011-A , Computer Tool Kit Maxicom 8In1 , Computer Tool Kit Maxicom M325 32In1 , Converter Hdmi Male Female Ranz , Converter Ranz Hdmi To Vga , Converter Ranz Type C To Vga , Converter Usb To Hdmi , Converter Vga To Hdmi , Cooler Ant Esports Ice C612 Digital , Cooling Pad Laptop Coco Sports Flow11 , Cooling Pad Laptop Coco Sports Flow12 , Cooling Pad Laptop Coco Sports Flow13 , Cooling Pad Laptop Coco Sports Flow14 , Cooling Pad Laptop Coco Sports Flow15 , Cooling Pad Laptop Coco Sports Flow16 , Cooling Pad Zeb Nc3300 , Cooling Pad Zeb Nc7000 , Cooling Pad Zeb Nc9000 , Cooling Pad Zebronics Nc2100 , Cpu Amd Ryzen 3 3200G , Cpu Amd Ryzen 5 3400G , Cpu Amd Ryzen 5 3600 Tray , Cpu Amd Ryzen 5 4600G , Cpu Amd Ryzen 5 5500 , Cpu Amd Ryzen 5 5600 , Cpu Amd Ryzen 5 5600G , Cpu Amd Ryzen 5 5600Gt , Cpu Amd Ryzen 7 5700 , Cpu Amd Ryzen 7 5700X , Cpu Amd Ryzen 7 8700F , Cpu Amd Ryzen 7 Without Cooler 5700X , Cpu Amd Ryzen 7 Without Cooler 5800X , Cpu Amd Ryzen 9 9900X , Cpu Cooling Fan Cooler Master 240L Core Argb , Cpu Cooling Fan Cooler Master Hyper 212 Spectrum V3 , Cpu Fan 478 Socket , Cpu Fan 775 & 1155 Combo Frontech , Cpu Fan Cooler Master Hyper T20 , Cpu Fan Lapcare Venus , Cpu I3 3Rd Gen , Cpu I3 4Th Gen , Cpu I5 3Rd Gen , Cpu I5 4Th Gen , Cpu I5 6Th Gen , Cpu I7 12Gen 12700K , Cpu Intel I3-10105 Lga1200 , Cpu Intel I3 12100F , Cpu Intel I3-12100 Lga1700 , Cpu Intel I5-11400 Lga1200 , Cpu Intel I5-12400F , Cpu Intel I5-12400 Lga 1700 , Cpu Intel I5-9500 , Cpu Intel I7 12700 , Cpu Intel I7 8700T , Crimping Tool , Crimping Tool 3In 1 , Dell 3511 Laptop Panel Abh , Desktop Hp Slim S01-Pf2888in , Desktop Power Cable 1.5M , Desktop Power Cable Ranz1.5M , Desktop Power Cable Ranz 5M , Desktop Power Extention 1.5M , Dotmatrix Printer Cable Ranz 1.5M , Dp Cable Orginal 1.5M , Dp Cable Ranz 1.5M , Dp To Hdmi Cable 1.8 Mtr. , Dp To Hdmi Converter , Dp To Hdmi Converter Ranz , Dp To Vga Converter Ranz , Drum 56A/K2200 , Drum Unit 104A , Drum Unit 19A , Dvd Frontech , Dvd Rw Drive Asus 8X Lite External , Dvi Cable Original 1.5M , Electric Blower Machine Ranz , Electric Blower Machine Ranz Gold , Encoder Strip Gt5810/20 , Epson Maintanance Box , Fan Cpu Ranz , Fan Intel 1155 , Fan Intel Original 1155 , Fan Ranz Q50 , Finger Print Mantra Mfs 100 , Finger Print Mantra Mfs 110 , Formatter & Logic Card 1020 Original , Game Pad Ant Esports Wireless Gp400 Black , Game Pad Ant Esports Wireless Gp400 White , Graphics Card 2Gb Ddr3 Gt 610 Frontech , Graphics Card 2Gb Ddr3 Gt610 Vga Geonix , Graphics Card 4Gb Ddr3 Grp0002 , Graphics Card 4Gb Ddr3 Gt730 Frontech , Graphics Card 4Gb Ddr3 Gt740 Frontech , Graphics Card 4Gb Msi 730 , Graphics Card Asrock 4Gb Rx550 Pg , Graphics Card Asrock Rx550 4Gb Pg , Handheld Inkjet Printer 12.7Mm , Hdd 1Tb External Hv320 Adata , Hdd 1Tb External Seagate Expension , Hdd 1Tb Seagate 3.5 , Hdd 2Tb External Hd710 Pro Adata , Hdd 2Tb Seagate 3.5 , Hdd 2Tb Surveillance Seagate , Hdd 4Tb Seagate 3.5 , Hdd 500Gb Consistent Sata , Hdd 5Tb External Wd Passport , Hdd Bag Ranz Case , Hdd Cable Ranz 1M , Hdd Caddy 2.5 Ranz , Hdd Casing 3.5 Smartpro , Hdd Casing Coco Sports 2.5 Sata Usb 2.0 , Hdd Casing Ranz 2.5 Sata 2.0 , Hdd Casing Ranz 3.0 , Hdd Casing Ranz 3.5 Sata 2.0 , Hdd Sata Power Cable , Hdmi Cable 1.5 Mtr , Hdmi Cable Lapcare 1.5M , Hdmi Cable Original 1.5M , Hdmi Cable Ranz 10M , Hdmi Cable Ranz 15 Mtr , Hdmi Cable Ranz 20M , Hdmi Cable Ranz 3M , Hdmi Cable Ranz 5 Mtr , Hdmi Extension Male To Female Cable , Hdmi Splitter , Hdmi Switch 3 Port With Remote , Hdmi To Av , Hdmi To Dvi Cable Smart Pro 1.5M , Hdmi To Dvi Joiner , Headphone Frontech Gaming Hf-0011 , Headphone Hp , Headphone Logitech H340 , Headphone Ranz 808 , Ink Bank Tvs , Ink Bottle Brother 5000 Cyan , Ink Bottle Brother 5000 Magenta , Ink Bottle Brother 5000 Yellow , Ink Bottle Brother Btd60 Black , Ink Bottle Canon 71 Black , Ink Bottle Canon 71 Cyan , Ink Bottle Canon 71 Magenta , Ink Bottle Canon 71 Yellow , Ink Bottle Canon 73 Black , Ink Bottle Canon 73 Cyan , Ink Bottle Canon 73 Gray , Ink Bottle Canon 73 Magenta , Ink Bottle Canon 73 Red , Ink Bottle Canon 73 Yellow , Ink Bottle Canon 790 Black , Ink Bottle Canon 790 Cyan , Ink Bottle Canon 790 Magenta , Ink Bottle Canon 790 Yellow , Ink Bottle Epson 001 Black , Ink Bottle Epson 001 Cyan , Ink Bottle Epson 001 Magenta , Ink Bottle Epson 001 Yellow , Ink Bottle Epson 003 Black , Ink Bottle Epson 003 Cyan , Ink Bottle Epson 003 Magenta , Ink Bottle Epson 003 Yellow , Ink Bottle Epson 005 Black , Ink Bottle Epson 008 Black , Ink Bottle Epson 008 Cyan , Ink Bottle Epson 008 Magenta , Ink Bottle Epson 008 Yellow , Ink Bottle Epson 057 Black , Ink Bottle Epson 057 Cyan , Ink Bottle Epson 057 Light Cyan , Ink Bottle Epson 057 Light Magenta , Ink Bottle Epson 057 Magenta , Ink Bottle Epson 057 Yellow , Ink Bottle Epson 6641 Black , Ink Bottle Epson 6642 Cyan , Ink Bottle Epson 6643 Magenta , Ink Bottle Epson 6644 Yellow , Ink Bottle Epson 673 Black , Ink Bottle Epson 673 Cyan , Ink Bottle Epson 673 Light Cyan , Ink Bottle Epson 673 Light Magenta , Ink Bottle Epson 673 Magenta , Ink Bottle Epson 673 Yellow , Ink Bottle Epson 774 Black , Ink Bottle Epson 774 Black Mini , Ink Bottle Hp Gt52 Cyan , Ink Bottle Hp Gt52 Magenta , Ink Bottle Hp Gt52 Yellow , Ink Bottle Hp Gt53 Black , Ink Cartridge Canon 47 Black , Ink Cartridge Canon 57 Color , Ink Cartridge Canon 745 Black , Ink Cartridge Canon 746 Color , Ink Cartridge Hp 27 Black , Ink Cartridge Hp 46 Black , Ink Cartridge Hp 46 Tri Colour , Ink Cartridge Hp 678 Black , Ink Cartridge Hp 680 Black , Ink Cartridge Hp 680 Colour , Ink Cartridge Hp 682 Black , Ink Cartridge Hp 682 Tri Colour , Ink Cartridge Hp 703 Tri Color , Ink Cartridge Hp 802 Black , Ink Cartridge Hp 802 Tri Colour , Ink Cartridge Hp 803 Black , Ink Cartridge Hp 805 Black , Ink Cartridge Hp 805 Tri Colour , Iphone 13 128Gb Blue_Mlpk3hn/A , Iphone 15 128Gb Green_Mtp53hn/A , Izi/Microphone/ X Wireless System , Izi/Others/ One+ 5K Action , Izi/Others Pro Nano Drone , Izi/Others Sky Pro Sa20mp Drone , Joypad Zebronics Zeb-V260jp , Kbm Ant Esports Km540 , Kbm Cococonut Bling Wireless , Kbm Coconut Daisywireless , Kbm Coconut Poppy Wireless , Kbm Combo Wireless Lapcare Wi-201 Black , Kbm Dell Km3322w Wireless , Kbm Frontech Kb0048 Keyboard+Mouse Wired , Kbm Hp Km200 Wireless , Kbm Hp Km260 Wireless , Kbm Intex Wireless Combo (Power New) , Kbm Logitech Mk120 , Kbm Logitech Mk220 Wireless , Kbm Logitech Mk240 Wireless White , Kb+Mouse Coco Sports Wired Combo , Kb+Mouse Coco Sports Wired Fury K15+Gm15 , Kbm Usb Hp Km150 , Kbm Usb Zebronics Gaming White+Sil , Kbm Wired Combo Coco Sports Cola K33+Gm33 Black , Kbm Wired Combo Coco Sports Mango K25 , Kb Ps2 Prodot Kb 207 , Kb Usb Dell Usb Kb216 , Kb Usb Frontech Kb 0007 , Kb Usb Hp K100 , Kb Usb Lapcare E9 , Kb Usb Lapcare Lkb 399 , Kb Usb Lapcare Mini D-Lite+Blk , Kb Usblapcare Mini D-Lite Silver , Kb Usb Tvs Champ , Kb Usb Tvs Champ Plus , Kb Usb Tvs Gold Prime , Kb Wireless Lapcare Mini D-Lite+Blk , Keyboard Coco Sports Mini Gaming Virgo K21 , Keyboard Frontech Black Usb 1672 , Keyboard Frontech Gaming Combo Kb-0034 , Keyboard Frontech Gaming Combo Kb-0035 , Keyboard Frontech Gaming Combo Kb-0039 , Keyboard Frontech Gaming Combo Kb-0042 , Keyboard Frontech Gaming Kb0049 , Keyboard Frontech Kb0046 , Keyboard Hp Usb K160 , Keyboard Hp Wired Combo Km160 (99Y13aa) , Keyboard Laptop Dell , Keyboard Laptop Hp , Keyboard Laptop Lenovo 440 , Keyboard Laptop Lenovo With Power Switch , Lamination Paper65*95 Mm , Lamination Paper Excelam A4 , Lamination Roll 9 , Laminator Frontech Lam 0001 , Laminator Frontech Lam-0003 , Laminator Gobbler Type-320 , Laminator Gobbler Type-330 , Lan Cable Cat 6 Adnet 5M , Lan Cable Cat 6 Digisol 305 Mtr Blue , Lan Cable Cat 6 Digisol 305Mtr Red , Lan Cable Cat 6 Digisol 305 Mtr Yellow , Lan Cable Cat 6 Finolex 305Mtr , Lan Cable Cat 6 Microtek 305 Mtr , Lan Cable Cat 6 Ranz 10M , Lan Cable Cat 6 Ranz 10M Premium , Lan Cable Cat 6 Ranz 1.5M , Lan Cable Cat 6 Ranz 2M , Lan Cable Cat 6 Ranz 2M Premium , Lan Cable Cat 6 Ranz 305 Mtr Box , Lan Cable Cat 6 Ranz 305 Mtr Roll , Lan Cable Cat 6 Ranz 3M , Lan Cable Cat 6 Ranz 3M Premium , Lan Cable Cat 6 Ranz 5M , Lan Cable Cat 6 Ranz 5M Premium , Lan Tester Rj45 Smartpro , Laptop Acer Aspire Lite Al 15-52 , Laptop Asus Creator K3605zc-Rp587ws , Laptop Asus Creator K3605zf-Rp458ws , Laptop Asus E1404fa-Nk522ws , Laptop Asus E1504fa-Lk541ws , Laptop Asus E1504fa-Nj321ws , Laptop Asus E1504fa-Nj322ws , Laptop Asus E1504ga-Lk321ws , Laptop Asus E1504ga Nj321ws , Laptop Asus Tuf Fa506nc-Hn083w , Laptop Asus Tuf Fa506nf-Hn578w , Laptop Asus Tuf Fa507nur-Lp082w , Laptop Asus Tuf Fa566nc-Hn083ws , Laptop Asus Tuf Fa566ncr-Hn054ws , Laptop Asus Tuf Fa566nfr-Hn045ws , Laptop Asus Tuf Fx507zc4-Hn116w , Laptop Asus Tuf Fx577zc-Hn192ws , Laptop Asus Vivobook X1500ea-Ej122ws , Laptop Asus Vivobook X1504za-Nj321ws , Laptop Asus Vivobook X1504za-Nj322ws , Laptop Asus X1504va-Nj320ws , Laptop Asus X1504va-Nj522ws , Laptop Asus X1504va-Nj540ws , Laptop Asus X1504za-Nj342ws , Laptop Asus X1504za-Nj520ws , Laptop Asus X1504za-Nj542ws , Laptop Asus X1605zac-Mb540ws , Laptop Asus X1605zac-Mb741ws , Laptop Dell Inspiron 3525 Oin35255271rins1 , Laptop Dell Inspiron In3535hf8x1003orb1 , Laptop Dell Inspiron Oin352010031rinb1m , Laptop Dell Inspiron Oin352010031rins1m , Laptop Dell Inspiron Oin352010091rins1m , Laptop Hp 14S-Dq5138tu , Laptop Hp 15-Fc0026au , Laptop Hp 15-Fc0154au , Laptop Hp 15-Fc0155au , Laptop Hp 15-Fd0061tu , Laptop Hp 15-Fd0070tu , Laptop Hp 15-Fd0186tu , Laptop Hp 15S-Fq5327tu , Laptop Hp Pav X360 Laptop 14-Ek2033tu , Laptop Hp Victus Gaming 15-Fa1317tx , Laptop Hp Victus Gaming 15-Fa1414tx , Laptop Keyboard Guard , Laptop Lamination Ranz , Laptop Lenovo 82R400bgin , Laptop Lenovo 82Rj00fuin , Laptop Lenovo 82Yua017in , Laptop Lenovo 83Eq005tin , Laptop Lenovo 83Gs008sin , Laptop Power Cable Premium 1.5 Mtr , Laptop Power Cable Ranz 1.5M , Laptop Screenguard , Laptop Screen Guard Ranz 3 In 1 , Laptop Screen Protector Ranz , Laptop Stand Ranz Cfb , Liquid Cooler Ant Esports Ice Chroma 240Argb Black , Liquid Cooler Ant Esports Ice Chroma 240Argb White , Logitech Presenter W/L R400 , Mb Asus Prime A520m-K , Mb Asus Prime H610m-Cs D4 , Mb Frontech Ft-0460 H55 , Mb Frontech Ft-0470 H61 , Mb Frontech Ft-0471 H81 , Mb Frontech Ft-0486 B250 , Mb Frontech H110 Jil-0475 , Mb Geonix Gx-H61 D3 , Mb Geonix H81 With Nvme Slot , Mb Gigabyte B450m K , Mb Gigabyte B550m K , Mb Gigabyte Ga-H310m-M.2 2.0 , Mb Lapcare H61 With Nvme Slot , Mb Msi H510m-A Pro , Mb Msi H510m-B Pro , Mb Zebronics H61 (Zeb-H61nvme) , Mic Frontech Hf-0009 , Microphone Sonilex , Mic Zeb Lucid Pro , Mic Zeb Lucid Rgb , Mi Earphone Basic Blue (Vn) , Mi Earphone Basis Black (Vn) , Monitor Benq 24 Gw2490 , Monitor Benq 27 Gw2790 , Monitor Benq 27 Gw2790q Black , Monitor Dell D2020h , Monitor Frontech Mon-0022 22.0 Led , Monitor Frontech Mon0061 18.5 Led , Monitor Frontech Mon -0070 22 Led (G) , Monitor Frontech Mon0071 19 , Monitor Frontech Mon0072c 24 Curved (G) , Monitor Frontech Mon00790 22 Curved (G) , Monitor Frontech Mon0088 24 Curved Fhd (G) , Monitor Hp 21.5 V22v , Monitor Hp V20 19.5 , Monitor Samsung 24 Ls24c366eawxxl , Monitor Viewsonic Va1903h-2 18.5 , Monitor Viewsonic Va2215-Mh 22 , Monitor Viewsonic Va2432-H-W 24 , Monitor Viewsonic Va2432-Mh 24 , Monitor Viewsonic Va2732-Mh 27 , Monitor Viewsonic Va3209-Mh 32 , Monitor Viewsonic Vx2758a-2K-Pro-2 , Monitor Viewsonic Vx2779-Hd-Pro 27 , Morpho E3 1300 Rdl1 , Mouse Pad Big Gaming X88 , Mouse Pad Big Shortcut Key , Mouse Pad Comfort , Mouse Pad Comfort Gel , Mouse Pad Dell , Mouse Pad (Git New) , Mouse Pad Led-01 Rgb , Mouse Pad Logilily , Mouse Pad Logitech , Mouse Pad (Ol Git) , Mouse Pad Pubg , Mouse Pad Q6 , Mouse Pad Ranz , Mouse Pad Rog , Mouse Usb Dell Ms116 , Mouse Usb Frontech Gaming Ms 0082 , Mouse Usb Frontech Ms0064 , Mouse Usb Frontech Ms 0066 , Mouse Usb Frontech Ms0067 , Mouse Usb Frontech Ms0068 , Mouse Usb Hp M050 , Mouse Usb Hp M10 , Mouse Usb Iball Style36 , Mouse Usb Intex Eco 8 , Mouse Usb Lapcare L70+ , Mouse Usb Logitech M90 , Mouse Wireless Asus Md100 , Mouse Wireless Clarion Jm Wm 209 , Mouse Wireless Coco Sports Bluetooth Glory , Mouse Wireless Dell Wm118 , Mouse Wireless Foxin Fwm 9099 , Mouse Wireless Frontech Ms 0033 , Mouse Wireless Frontech Ms 0040 , Mouse Wireless Hp M120 , Mouse Wireless Lenovo 130 , Mouse Wireless Logitech M170 , Multybyte Adapter 5V 2A , Note Counting Machine Gobbler Gb-3288E , Note Counting Machine Gobbler Gb-5288 , Note Counting Machine Gobbler Gb-9788 E , Oppo A3x Ocean Blue (4+64Gb) , Oppo A3x Starry Purple (4+64Gb) 5G , Otg Type C Female Usb Male 2.0 , Otg Type C Female Usb Male 3.0 , Otg Usb Type C Ranz , Paper Canon A4 70Gsm , Paper Photo A4 , Paper Roll 57Mm A3 , Paper Thermal Rolll 79Mm 3 , Pci Express Adaptor Tl-Wn781n 150Mbps , Pci Express Usb Card Smacc , Pci Express W/L Adapter Tp-Link Tl-Wn881nd , Pci Parallel Card S-Tech , Pci Serial Card Enter , Pci Sound Card Enter , Pci Usb Card 2.0 Enter , Pcp Carriage 5810 , Pen Drive 128Gb Hp 3.0 X796w , Pen Drive 128Gb Sandisk 2.0 , Pen Drive 32Gb Hp 2.0 V236w , Pen Drive 32Gb Sandisk 2.0 , Pen Drive 32Gb Sandisk 3.0 Otg , Pen Drive 64Gb Hp 2.0 V236w , Pen Drive 64Gb Sandisk 2.0 , Pendrive Kingstone Data Traveler Exodia 256Gb , Pendrive Kingstone Data Traveler Exodia 64 Gb , Photo Paper A4 Kodak , Portable Microphone Single K8 , Portable Microphone Single K9 , Pos Service Fee , Power Cable 2 Pin , Power Cable Laptop Dell Original , Power Cord Laptop Ranz , Precision Pb1000 L1 Device , Precision Pb510 , Printer Cable Lapcare 1.5M (7994) , Printer Cable Lapcare 3 Mtr. , Printer Cable Original , Printer Cable Ranz 10M , Printer Cable Ranz Bm Gold 10 M , Printer Cable Ranz / Volt It 1.5M , Printer Cable Ranz / Volt It 3M , Printer Cable Ranz / Volt It 5M , Printer Cable Usb 5Mtr 3.0 , Printer Epson M2170 Epil , Printer Epson Plq-35 Impact Dot Matrix , Printer Hp Deskjet 1212 , Printer Hp Lasejet Pro P1108 Plus , Printer Hp Laserjet M126nw , Printer Hp Laserjet Pro M126a , Printer Hp Never Stop Laser Mfp 1200A , Printer Hp Smart Ink Tank 580 , Printer Hp Smart Ink Tank 581 , Printer Inkjet Brother Dcp-T420w , Printer Inkjet Canon G2010 , Printer Inkjet Canon G2730 , Printer Inkjet Canon G3010 , Printer Inkjet Canon G3730 , Printer Inkjet Epson Ecotank L3210 , Printer Inkjet Epson Ecotank L3250 , Printer Inkjet Epson Ecotank L5290 , Printer Inkjet Epson Ecotank L8050 , Printer Inkjet Epson L130 , Printer Inkjet Epson M200 , Printer Inkjet Hp Smart Tank 520 , Printer Inkjet Hp Smart Tank 521 , Printer Inkjet Hp Smart Tank 524 , Printer Inkjet Hp Smart Tank 525 , Printer Inkjet Hp Smart Tank 584 , Printer Inkjet Hp Smart Tank 585 , Printer Laser Pantum M6518 , Printer Power Cable Ranz 1.5M , Printer Tvs Msp 270 Classic Plus Dot Matrix , Printhead Canon Bh-70 Black , Printhead Canon Bh-7 Black , Printhead Canon Ch-70 Color , Printhead Canon Ch-7 Color , Print Head Epson L220/360/3110 , Printhead Hp M0h0aa Tri Colour , Printhead Hp M0h51aa Black , Printhead Hp X4e75aa Black , Projector Celling Mount Stand 2Ft , Projector Epson Eb-E01 , Projector Stand Tripod Screen High Gain 4X6 , Psd Range Brochure-Print Outside The Box , Pvc Box 5X5 , Pvc Card Epson , Pvc Card Pinu Gold , Ram Desktop 16Gb Ddr4 Corsair Vengeance Lpx , Ram Desktop 16Gb Ddr4 Crucial , Ram Desktop 16Gb Ddr4 Pc3200 Starlite , Ram Desktop 16Gb Ddr4 Xpg Gamix D35 Black , Ram Desktop 16Gb Ddr5 Xpg Lancer Black , Ram Desktop 1Gb Ddr2 Memlite , Ram Desktop 2Gb Ddr3 Kingston Accer , Ram Desktop 4Gb Ddr3 Frontech , Ram Desktop 4Gb Ddr3 Hynex , Ram Desktop 4Gb Ddr4 Crucial , Ram Desktop 8Gb Ddr3 1600 Hynix , Ram Desktop 8Gb Ddr3 Frontech , Ram Desktop 8Gb Ddr3 Geonix , Ram Desktop 8Gb Ddr3 Pc1600 Starlite , Ram Desktop 8Gb Ddr4-2666 Hynix , Ram Desktop 8Gb Ddr4 Crucial , Ram Desktop 8Gb Ddr4 Pc3200 Starlite , Ram Desktop 8Gb Ddr4 Xpg Gamix D30 , Ram Desktop 8Gb Ddr4 Xpg Gamix D35 Black , Ram Laptop 16Gb Ddr4 Crucial , Ram Laptop 16Gb Ddr4 Pc3200 Starlite , Ram Laptop 1Gb Ddr2 Transcend Crucial , Ram Laptop 1Gb Ddr3 Samsung , Ram Laptop 4Gb Ddr3 Geonix , Ram Laptop 4Gb Ddr3 Starlite , Ram Laptop 512Mb Ddr2 Ramaxel , Ram Laptop 8Gb Ddr3 Pc1600 Starlite , Ram Laptop 8Gb Ddr4 Crucial , Ram Laptop 8Gb Ddr4 Pc3200 Starlite , Ram Laptop 8Gb Ddr5 Crucial 4800Mhz , Ranz Otg C Type Female Usb Male , Realme 13 5G Speed Green (8+128Gb) , Realme 14X 5G Crystal Black (8+128Gb) , Realme 14X 5G Golden Glow (6+128Gb) , Realme 14X 5G Golden Glow (8+128Gb) , Realme C61 Marble Black (4+64Gb) , Realme C63 Starry Gold (6+128Gb) , Realme P1 Speed 5G Textured Titanium (8+128Gb) , Redmi 12 5G Jade Black (8+256Gb) , Redmi 13C 5G Startrail Green (6+128Gb) , Redmi 13C 5G Startrail Silver (6+128Gb) , Redmi 14C 5G Starlight Blue (4+128Gb) , Redmi A3 Lake Blue (4+128Gb) , Redmi A3 Lake Blue (6+128Gb) , Redmi A3 Olive Green (6+128Gb) , Redmi Note 13 Pro 5G Coral Purple (8+256Gb) , Rgb Fan Nubwo Airforce Nft-100 , Ribbon Formujet Max Pr-02 , Ribbon Formujet Plq20 , Ribbon Lipi Pr-02 , Ribon Cartridge Formujet Lx310/Lq310 , Ribon Cartridge Formujet Plq 20/30 , Ribon Cartridge Lipi Plq 20 , Rj45 Connector , Rj45 Connectord-Link , Rj45 Lan Cable Cat 6 Finolex , Rj45 Switch D-Link 8Port , Rj45 Switch Mercusys 8Port Ms108g , Router D-Link Ac1200 Dual Band Dir811in , Router D-Link Wireless N300 , Router Lapcare 4G Sim 4-Antena Wi-Fi-6 , Router Tp-Link 1 Port Gigabit , Router Tp-Link Ac1200 Wi-Fi Router Archer C6 , Router Tp-Link Ac750 Wireless Dual Band Archer C24 , Router Tp-Link Wireless 300Mbps Tl-Wr820n , Rt Toner Drum-2/Chip-2/Blade-1 , Samsung Ep-T2510nbngin , Samsung Sgh Gt-E156 Jazzy Green (4+128Gb) , Samsung Sgh Gt M145 Arctic Blue (4/64Gb) , Screen Laptop 15.6 Normal Led 40 Pin 6048 , Screen Laptop 15.6 Paper 30 Pin Fhd , Screen Laptop 15.6 Paper Led 30Pin , Screen Laptop 15.6 Paper Led 40 Pin 6050 , Screen Led Laptop Lapcare , Screen Led Laptop Zeb Lsg15630cn , Secureye Xpon Onu 1110 Ont Data+Voice+Wifi , Simmtronics 128Gb Micro Sd Class 10 , Smart Pro Extension Board 4 Switch 1.8 Mtr , Smart Pro Extension Board 4 Switch 4.8 Mtr , Smart Pro Extension Board 6 Switch 1.8 Mtr , Smps Clarion Jm-Ps-920 , Smps Frontech 450W Ps-0005 , Smps Frontech 450W Ps0012 , Smps Frontech Pro 1000 Ps-0014 , Smps Geonix 500 Watt , Smps Gigabyte Gp-450B W 80+ Bronze , Smps Gigabyte Gp-P550b 550 Watt Bronze , Smps Lapcare 450W , Smps Msi Mag 550W A550bn , Smps Msi Mag 650W A650bn , Speaker Bluetooth Boat Stone 352 Pro , Speaker Bluetooth Boat Stone 358 Pro , Speaker Bluetooth Boat Stone Spinx Pro , Speaker Bluetooth Zeb Mob Action Blk , Speaker Coconut Us06 , Speaker Frontech Spk-0003 , Speaker Frontech Spk-0005 , Speaker Hp 360 Silver Bluetooth , Speaker Hp Multimedia Dhs-2111 , Speaker Lapcare Lus-009 , Speaker Lapcare Lus-040 , Speaker Lapcare Lus-204 , Speaker Wireless Hp S300 , Spike Guard Ranz , Spike Guard Voltit 4 Sw 1.8Mtr. , Ssd 1Tb Portable Crucial X6 , Ssd 1Tb Portable Sandisk E-30 , Ssd 2Tb Lexar Sl200 Portable , Ssd M.2 256Gb Simmtronics S950p Pro , Ssd Nvme 128Gb Evm , Ssd Nvme 250 Gb Wd Green Sn350 , Ssd Nvme 256Gb M.2 Lexar Nm620 , Ssd Nvme 256Gb Scuda , Ssd Nvme 480Gb Crucial E100 , Ssd Nvme 500Gb Crucial P3 3D Nand , Ssd Nvme 500Gb Crucial P3 Plus Gen4 3D , Ssd Nvme 500 Gb Wd Green Sn350 , Ssd Nvme 512Gb M.2 Pcie Scuda , Ssd Nvme Crucial P3 Plus 500Gb Gen4 , Ssd Nvme P3 1Tb Crucial 3D Nand , Ssd Sata 1000Gb Crucial Bx500 , Ssd Sata 128Gb Intex , Ssd Sata 128Gb Lapcare , Ssd Sata 240Gb Lexar Nq100 , Ssd Sata 240Gb Wd Green , Ssd Sata 256Gb Colorfire Gamepower , Ssd Sata 256Gb Frontech , Ssd Sata 256Gb Scuda , Ssd Sata 480/500Gb Lexar Nq100 , Ssd Sata 480Gb Wd Green , Ssd Sata 500Gb Crucial Bx500 , Ssd Sata 512Gb Frontech , Sundisk Ultra Micro Sd 512Gb , Switch 2 Port Usb Ad Net , Switch 2 Port Usb Mckrocdgc , Switch 5 Port Dlink 10/100 Un Magd Des-1005C , Tab Acer One 7 4G , Tally Prime Silver Edition , Tallyprime With Whatsapp - New Subscription , Tally Software Service-Gold , Tally Software Service-Silver , Thermal Printer Tm-T82x-461 Epson , Thermal Receipt Printer Gobbler 58Mm Hop H58 , Thermal Receipt Printer Gobbler 58Mm Hop H58 (U+B) , Thermal Receipt Printer Sp-Pos891usd , Toner Cartridge 152A , Toner Cartridge 18A With Chip , Toner Cartridge Brother Tnb021 , Toner Cartridge Canon 071 , Toner Cartridge Cf247a Volt It , Toner Cartridge Cf256a/56X , Toner Cartridge Chip Cl256a/56A , Toner Cartridge H-166Hp Black , Toner Cartridge H-388A , Toner Cartridge H-505A/280A , Toner Cartridge Hp 103A , Toner Cartridge Hp 103Ad , Toner Cartridge Hp 158A (W1580a) , Toner Cartridge Hp 158X (W1580x) , Toner Cartridge Hp 56A , Toner Cartridge Hp Laserjet 335X , Toner Cartridge Hp Original 78A , Toner Cartridge H-W1112a (110 A) , Toner Cartridge Ice-337 , Toner Cartridge Jf-2612A , Toner Cartridge Lpc278a , Toner Cartridge Lpc279a , Toner Cartridge Lpcd111s , Toner Cartridge Ml-1610D2 , Toner Cartridge Mlt D 101 , Toner Cartridge P-Pg208kev Black , Toner Cartridge Tc-3238 , Toner Cartridge Tn-1020 , Toner Cartridge Tn-116 , Toner Cartridge Tn2365 , Toner Cartridge Tn2465 , Toner Cartridge Tn-420 , Toner Cartridge Volt It 35A/36A/85A/925 , Toner Cartridge Voltitbrother B-Tn B20/21/22/23 , Toner Cartridge W1370a/137A , Tp-Link Ac600 Wl+Bt Usb Adapter Archer T2ub Nano , Tp-Link Eathernet Adapter 3.0 Ue330 , Tp-Link Eathernet Adapter Type-C Ue300c , Type C Printer Cable Ranz 1.5M , Type-C To Nvme Ssd Casing , Type C To Usb Otg Orginal , Ugreen Pci Exp Gigabit Adaptor Us230-30771 , Ups Apc 1100Va , Ups Apc Bx600c-In , Ups Battery Cyber Power , Ups Fingers Fr-1250Lcd , Ups Frontech Ft-2569 Force 725 , Ups Frontech Ft-2570 1Kva , Ups Frontech Ft-2571 Static Converter Voltex 1.2 Kv , Ups Microtek Legend 1000 1Kva , Ups Microtek Legend 750M , Ups Zebronics U735 , Usb A To Lightning Port Cable Lapcare , Usb Bluetooth Dongle 5.0 , Usb Cable 1.5M Kral , Usb Combo ( Hub+Card Reader) 3.0 , Usb C Power Adapter (20Watt)_Muvr3hn/A , Usb Dongle Lapcare 4G Lte , Usb Extension Cable 3.0-5Mtr Maxicom , Usb Extension Cable 5Mtr Terabyte , Usb Extension Cable Adnet 3M , Usb Extension Cable Kral 3M , Usb Extension Cable Ocean 1.5M , Usb Extension Cable Ranz 10M , Usb Extension Cable Ranz 5M , Usb Extension Cable Volt It Cable 1.5M , Usb Hub Clarion 3.0 4 Ports Jm-Usbh-008 , Usb Hub Frontech Nc-0007 , Usb Hub Frontech Nc-0011 , Usb Hub Lapcare2.0 4Port Lhb-006 , Usb Hub Type C Ranz 4 Port , Usb Hub Volt It 4 Port 3.0 Metal , Usb Male-Female Cable Lapcare 1.5Mtr , Usb To Lan Card Ranz Type C , Usb To Lan Ranz 2.0 , Usb To Lan Ranz 9700 , Usb To Lan Smartpro 2.0 Metal , Usb To Mini Usb Cable , Usb To Paralal Converter , Usb To Ps2 Converter , Usb To Sound Card Ranz , Usb To Usb Cable 1.5M , Usb To V3 Cable Ranz 1.5M , Usb Wifi Adapter Tp-Link Tl-Wn823n , Usb Wifi Dongle + Bluetooth Ranz , Usb Wifi Dongle + Bluetooth Volt It , Usb Wifi Dongle Geonix , Usb Wifi Dongle Lapair Lwd-300 , Usb Wifi Dongle Ranz 450M , Usb Wifi Dongle Volt It 802.11N , Vga Cable 1.5M Original , Vga Cable 1.5M Original Samsung , Vga Cable Lapcare , Vga Cable Lapcare Premium 3M , Vga Cable Ranz 10M , Vga Cable Ranz 1.5M , Vga Cable Ranz 3M , Vga Cable Ranz 5M , Vga Switch 2 Port , Vga Switch 4 Port , Vivo Charger V1530h0a0 - In White , Vivo T3 5G Vibrant Green (6+128Gb) Lite , Vivo T3x 5G Crimson Bliss (8+128Gb) , Vivo V40e Royal Bronze (8+256Gb) , Vivo V50 Starry Night (8+256Gb) , Vivo Y18i Space Black (4+64Gb) , Vivo Y18t Space Black (4+128Gb) , Vivo Y28e 5G Vintage Red (4+128G) , Vivo Y28e 5G Vintage Red (4+64G) , Vivo Y28e Breeze Green (4+64Gb)_C , Vivo Y28e Vintage Red (4+64G)_C , Vivo Y28s 5G Twinkling Purple (8+128Gb) , Vivo Y29 5G Diamond Black (8+256Gb) , Vivo Y29 5G Glacier Blue (6+128Gb) , Vivo Y29 5G Titanium Gold (8+128Gb) , Vivo Y300 5G Phantom Purple (8+128Gb) , Vivo Y300 5G Titanium Silver (8+256Gb) , Volt It Chip Hp-56/A , Wall Mount Kit 14-26 Fix , Wall Mount Kit 14-27 Moving Ranz , Wall Mount Kit 14-42 , Webcam Logitech C270 Hd , Webcam Logitech C505e , Webcam Logitech Fhd 1080P Brio 100 Graphite , Wifi Adapter Clarion Jm-Wl-300Mbps , Wifi Bt Adapter Clarion 600Mbps (Ja-2025) , Wifi Range Extender Tp-Link Ac750 Dual , Wifi Range Extender Tp-Link Tl-Wa850re , Windows 10/11 Pro For Oem Sticker , Windows 10 Pro Key Dvd Pack , Wireless Mouse Coco Sports Joy Wm31-Black , Wireless Speaker Coco Sports Bs02-Carman , Xiaomi Power Bank 4I 10000Mah , Xiaomi Power Bank 4I 20000Mah , Ips Sword , General Sword , Computer scanner , Computer scanner Cum Printer , Wbps Sword
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 11
West Bengal View Result →
11.
Information and Broadcasting #10811892 Price Bid
Tender For E-Tender For The Supply, Installation, Integration, Testing, And Commissioning Of Equipment, Computer Hardware, Software, And Accessories For Cinematography, Digital Intermediate, Audiography, Direction & Screenplay Writing, Film Editing, And Animation & Visual Effects Sections, On Academic Pricing On Turnkey Basis, Along With Comprehensive Onsite Warranty For Three (3) Years , Direction And Screenplay Writing Section - Equipment Requirements , Smart Tvpc Dell Pro Max Tower T2 - Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W), 64Gb (2 X 32 Gb) Ddr5 (5600 Mt/S, Non-Ecc), Nvidia Geforce Rtx 5090 32Gb Gddr7, 3Xdp, 1Xhdmi, 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready/ Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 /Windows 11 Pro / 5 Yrs Support , Smart Tv Sony Bravia 3 Series 189 Cm (75 Inches) 4 K Ultra Ai Smart Led Google Tv , Mac Studio M3 Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse , External Hard Drive Seagate One Touch 20Tb Usb 3.0 Portable Hdd , Printer Hp Laserjet Mfp M438Dn Multi-Function Monochrome Laser Printer (Toner Cartridge) , Directors Viewfinder Alan Gordan Enterprises Mark Vb Directors View Finder , Video Assist Monitors Blackmagic Video Assist 5 3G 5-Inch Full Hd Lcd Touchscreen 3G-Sdi And Hdmi Inputs/Outputs Supports Up To 1080P60 Recording , Final Draft Final Draft Software Full License (Industry Standard With Life Time License) , Continuity Camera / Script Notes Camera Canon Eos R50 Mirrorless Camera Body With Rf - S 18 - 45 Mm F/4.5 - 6.3 Is Stm , Walkie-Talkies, Head Phones (Sets) Aspera V-9 License Free Walkie Talkie With Standard Accessories Viz Battery, Belt Clip, Rapid Charger And Adaptor, Helifex Antenna, User Manual. , Portable Bluetooth/Monitor Speakers (On-Set Use) Jbl Xtreme 3, Wireless Portable Bluetooth Speaker, Pro Sound With Powerful Bass Radiators, Built-In Powerbank, Partyboost, Ip67 Water & Dustproof, Aux & Type C (Blue, Without Mic) , Digital Clap Board Tribe7 Blackslate7 7.5 Clapperboard E-Image Cb-03 Advanced , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Digital Intermediate Section - Equipment Requirements , Software Davinci Resolve Software Studio Version , Software Adobe Package Software (1 Year Subscription Yearly To Be Renewed) , Software Easy Dcp Software For Resolve , Color Correction Panel Black Magic Design Davinci Resolve Mini Panel , Color Correction Panel Black Magic Design Davinci Resolve Micro Panel , Imac Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse With 1-Year Support , Imac Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16-Core Neural Engine 120Gb/S Memory Bandwidth, 2Tb Ssd, 32Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours With 1-Year Support , Imac Mac Keyboard And Mouse Usb Hub 50000 X 1 No. , Dell Tower Work Stations Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non- Ecc / Nvidia Geforce Rtx 5090 32Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , Dell Tower Work Stations Logitech Mk120 Usb Keybord And Mouse , Dell Tower Work Stations Photoshop System 1 Year Licence Subcription To Be Renewed Annually , Monitor Dell Pro 27 Plus 4K Usb-C Hub Monitor - P2725Qe , Monitor Dell Pro 27 Plus Monitor - P2725H / 5Y Basic Advanced Exchange Service , Monitor Eizo Cg319X-4K / 31.1 Inches,4096X2160,350Cd/M2,Dp,Hdmi,Adobe Rgb, Built In Sensor , Tv Sony Bravia 4K Uhd Tv 65Inch , External Hard Disk Samsung Ssd 4 Tb External Hdd , External Hard Disk Seagate One Touch Backup Plus 5Tb Hdd External , Di Equipments Blackmagic Design Capture, Card Ultrastudio 4K Mini , Di Equipments Black Magic Design Ultrastudio Monitor 3G For Mac 15000 X 4 Nos , Di Equipments Black Magic Design Link Card 4K Extreme 12G , Speaker & Headphones Jbl Stage 260F, Stage 245C, Stage 240H, Stage 200P + Denon Avrx- 250 Bituminous Av Receiver 5.1 Home Theatre , Speaker & Headphones Jbl Sb180 Speakers , Speaker & Headphones Akg K52 Headphones , Accessories Wacom Intuos Bluetooth Ctl-6100/K0-Cx Digital Graphics Pen Tablet For Drawing (Black) Medium (10.4-Inch X 7.8-Inch) , Accessories Hdmi 2.1 -5 Metres , Accessoriest Thunderbolt 4(Usb-C) Pro Cable (3 Metres) , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Animation & Visual Effects - Equipment Requirements , System Lenovo Think Station Px Workstation | 2 X Intel Xeon Gold 5420+ Processor (2.00 Ghz Up To 4.10 Ghz) | 4 X 128 Gb Ddr5-4800Mt/S (Rdimm, Ecc) | 4 X 12 Tb 7200Rpm Hdd 3.5 Sata Enterprise | Nvidia Rtx A6000 48Gb | Intel Eagle Stream C741 Dual Processor Motherboard | Raid 10 (4 Drives Min) | 1 X 1 Tb Ssd M.2 2280 Pcie Gen4 Performance Tlc Opal | 1 X 4 Tb Ssd M.2 2280 Pcie Gen4 Performance Tlc Opal | Integrated Ethernet | 2 X Thermal Kit 250W | Windows 11 Pro 64Bit Pre-Loaded | Wired Keyboard & Mouse | 3 Years Onsite Warranty / Dell Ultrasharp 27 4K Thunderbolt Hub Monitor - U2725Qe , System Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non-Ecc / Nvidia Geforce Rtx 5090 32Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , System Dell Pro Max Tower T2 / Intel Core Ultra 9 285 (36 Mb Cache, 24 Cores, 24 Threads, 1.9 Ghz To 5.6 Ghz, 65W) / 64Gb: 2 X 32 Gb, Ddr5, 5600 Mt/S, Non-Ecc / Nvidia Geforce Rtx 5070 12Gb Gddr7 3Xdp 1Xhdmi / 1Tb Ssd Tlc With Dram M.2 2280 Pcie Gen4 Sed Ready / Dell Pro Max Tower T2 With 1500W (80 Plus Platinum) Psu V2 / Windows 11 Pro / 5Yrs Support , Software Adobe Creative Cloud All Apps Education Named Subscription License , Software Ai Tools (Google Flow) , Software Davinci Fusion Studio Annual-Commercial , Software Cine Tracer , Software Autodesk Maya Subscription New- Commercial , Software Houdini Academic License , Software Nuke Studio 1-Year Subscription , Laptop Dell Pro Max 16 (Mc16250) Xcto Base / Intel Core Ultra 5 235H, Vpro Enterprise (18Mb, 14 Cores, 14 Threads, Up To 5.00 Ghz Turbo, 45W) / 16Gb: 2X8Gb, Ddr5, 5600 Mt/S, Sodimm, Dual Channel, Non-Ecc / Nvidia C64 Rtx Pro 1000 Blackwell 8Gb Gddr7 / 16 Fhd+ Lcd With 300 Nits, Non- Touch, Fhd Hdr Rgb Camera, Microphone, Wlan / Intel Wi-Fi 6E Ax211, 2X2, 802.11Ax, Bluetooth 5.3 Wireless Card / 512Gb, M.2 2230, Gen4 Pcie Nvme, Ssd, Class 35 / 130W Ac Adapter, Type C (Tco10) / Windows 11 Home / 5Yrs Prosupport Nbd , Smart Tv Smart Tv-32 Inch , Moniters Dell Pro 27 Plus 4K Usb-C Hub Monitor - P2725Qe / 3Y Basic Advanced Exchange Service , Other Equipments Logitech Mk120 Usb Keybord And Mouse , Other Equipments Xp-Pen-Deco01 V3 , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Film Editing - Equipment Requirements , Apple Imac Machines Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16- Core Neural Engine 120Gb/S Memory Bandwidth, 2Tb Ssd, 32Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours With 1-Year Support , Mac Studio M3 Mac Studio, Apple M3 Ultra Chip 28-Core Cpu With 20 Performance Cores And 8 Efficiency Cores 60-Core Gpu Hardware-Accelerated Ray Tracing 32-Core Neural Engine 819Gb/S Memory Bandwidth, 256Gb Unified Memory, 2Tb Ssd, Keyboard & Mouse , Apple Cinema Display 27 Apple Studio Display 5K Retina Display 68.29 Cm / 27 (Diagonal) 5K Retina Display 5120X2880 Resolution At 218 Pixels Per Inch 600 Nits Brightness Support For 1 Billion Colours Wide Colour (P3) True Tone Technology With 1-Year Support , Sennheiser Headphones Hd 280 , Jbl Studio Jbl Monitors/Speakers , External System Connected Ssd External Wd 1Tb Drive , Licenses For Each Software Avid Media Composer Edu 1-Year Subscription New License , Licenses For Each Software Davinci Resolve Software , Licenses For Each Software Fcp Studio , Licenses For Each Software Adobe Premiere Pro Academic License 1-Year Subscription - 3 Nos. , External Backup Hard Drive Wd My Book Backup Drive - 12 Tb , Keyboard/ Mouse Logitech Mk120 Usb Keybord And Mouse , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Audiography - Equipment Requirements , Dubbing/Mixing Room - Hardware And Software Protool Ultimate Edu Subscription For Student/Teacher - New , Dubbing/Mixing Room - Hardware And Software Dolby Atmos Renderer , Dubbing/Mixing Room - Hardware And Software Pace Ilok 3 Usb - C Type , Dubbing/Mixing Room - Hardware And Software Merging Techologies Hapi Mkiii , Dubbing/Mixing Room - Hardware And Software Merging Technologies Ada8V3S 8 Ch Mic/Line Ad&Da 192 Khz , Dubbing/Mixing Room - Hardware And Software Merging Technologies Anubis Pro Sps , Dubbing/Mixing Room - Hardware And Software Avid S1 (Includes 1 Year Hw Warranty) , Dubbing/Mixing Room - Hardware And Software Avid S1 Extended Hw Support - Second Year , Dubbing/Mixing Room - Hardware And Software Avid Dock , Dubbing/Mixing Room - Hardware And Software Focusrite Isa428 Mkii 4-Channel Microphone Preamp , Dubbing/Mixing Room - Hardware And Software Apple Mac Studio M3 Ultra Chip With 28-Core Cpu, 60-Core Gpu, 32-Core Neural Engine, 96Gb Unified Memory, 1Tb Ssd Storage, Macos , Dubbing/Mixing Room - Hardware And Software Applecare+ For Mac Studio (M4 Max / M3 Ultra) , Dubbing/Mixing Room - Hardware And Software Sonnet Rackmac Studio Enclosure - 3U Pro Rackmount Enclosure To Install And Secure One Or Two Mac Studio Computers In A Standard 19-Inch Rack , Dubbing/Mixing Room - Hardware And Software Logic Pro - Professional Music Production , Dubbing/Mixing Room - Hardware And Software Steinberg Nuendo 14 - Software (Standard) , Dubbing/Mixing Room - Hardware And Software Benq 27 Inch 1080P Fhd Ips Monitor|Height Adjustable - 3 Year Warranty (2 Display For Each System) , Dubbing/Mixing Room - Hardware And Software Samsung 65 Tv For Console Room - 1.63 M (65) Crystal 4K Uhd Smart Tv , Dubbing/Mixing Room - Hardware And Software Samsung 55 Tv For Console Room - 1.38 M (55) Crystal 4K Uhd Smart Tv , Dubbing/Mixing Room - Hardware And Software Lg 4K Uhd Hybrid Projector , Dubbing/Mixing Room - Hardware And Software Motorised Projector Screen, 10 X 8 Feet, 150 Diag, 4:3 Aspect Ratio, 1080P-3D-4K With Remote , Dubbing/Mixing Room - Hardware And Software Logitech Mx Keys S Performance Combo - Black (Incl Mx Master 3S, Mx Keys S & Mx Palm Rest) , Dubbing/Mixing Room - Hardware And Software Blackmagic Design Ultrastudio Monitor 3G Sdi/Hdmi Playback Device , Dubbing/Mixing Room - Hardware And Software Thunderbolt 3 Cable (6.6, 40 Gb/S, Active) , Dubbing/Mixing Room - Hardware And Software Usb-C Digital Av Multiport Adapter (1 For Each System) , Dubbing/Mixing Room - Hardware And Software Usb C Hub 10Gbps 6-In-1 Multiport Adapter With 4K@60Hz Hdmi, Type A& C 3.2 Data Ports, 100W Pd For Mac , Dubbing/Mixing Room - Hardware And Software Tt0080831/ Netgear Av Line M4250-12M2Xf 12X2.5G And 2Xsfp+ Managed Switch , Dubbing/Mixing Room - Hardware And Software Izotope Rx 11 Standard , Dubbing/Mixing Room - Hardware And Software Mcdsp Sa2 Dialog Processor , Dubbing/Mixing Room - Hardware And Software Waves Diamond Bundle , Dubbing/Mixing Room - Hardware And Software Fab Filter Mixing Bundle , Dubbing/Mixing Room - Hardware And Software Audio Design Desk Subscription (2 Years) , Dubbing/Mixing Room - Hardware And Software Nugen Loudness Toolkit-2 , Dubbing/Mixing Room - Hardware And Software Sis Edicue , Dubbing/Mixing Room -Mics And Speakers Neumann Ma 1 Monitor Alignment Microphone And Calibration System , Dubbing/Mixing Room -Mics And Speakers Multi-Channel Extension For Neumann Ma 1 System Software , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 150 Dsp Powered Studio Monitor , Dubbing/Mixing Room -Mics And Speakers Height Adjustable Stands For Neumann Kh 150 , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 120 Ii Dsp Powered Studio Monitor (4 For Surrounds & 4 For Tops) , Dubbing/Mixing Room -Mics And Speakers Neumann Lh 32 Wall Mounts With Pan And Tilt (4 For Surrounds & 4 For Tops) , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 870 Ii Dsp Dual 10 Studio Subwoofer , Dubbing/Mixing Room -Mics And Speakers Neumann Kh 310 3-Way Reference Studio Monitors Pair (Left And Right) , Dubbing/Mixing Room -Mics And Speakers Kali Lp 6 (Talk Back Speaker Pair For Recording Booth) , Dubbing/Mixing Room -Mics And Speakers Sennheiser Hd 200 Pro Closed-Back Studio Headphones , Dubbing/Mixing Room -Mics And Speakers Neumann Tlm 103 Stereo Set- Nickel (2 X Tlm 103 Ni + Ea1 In Aluminium Case) , Dubbing/Mixing Room -Mics And Speakers Sennheiser E945 Supercardioid Dynamic Vocal Microphone , Dubbing/Mixing Room -Mics And Speakers Rs-719 Heavy Duty Microphone Boom Stand , Dubbing/Mixing Room -Mics And Speakers Rs-521 Medium Weight Notepad/Lyric Stand , Dubbing/Mixing Room -Mics And Speakers Presonus Hp4 Headphone Annual Periodical Maintenance , Dubbing/Mixing Room -Mics And Speakers Promise Pegasus R4 16 Tb Raid With 3 Years Warranty , Dubbing/Mixing Room -Mics And Speakers Rs T3 Pop Shield , Dubbing/Mixing Room -Mics And Speakers 4-Port Professional Hdmi 4K Automatic Video Switch With Fast Switching , Dubbing/Mixing Room -Mics And Speakers Audio Cables And Connectors (Set) And Testing And Calibration , Dubbing/Mixing Room -Mics And Speakers Audio Rack - Black Color With 7 Pairs L Angle With Screws & Nuts & 15 Amps Power Supply With Side Panel And Heavy Duty Wheels , Dubbing/Mixing Room -Mics And Speakers Active Optical Hdmi Cable 25M , Dubbing/Mixing Room -Mics And Speakers Heavy Duty Cat6 Cable 25M , Dubbing/Mixing Room -Mics And Speakers Usb 2.0 Extender Over Cat5E/Cat6 Cable (Rj45) - Up To 165Ft (50M) - High Speed Usb Port Extender Adapter Kit - Powered , Edit Suite- Hardware And Software Pro Tools Studio Annual Paid Annual Subscription Edu , Edit Suite- Hardware And Software Pace Ilok 3 Usb-C Type , Edit Suite- Hardware And Software Neumann Mt 48 Usb-C Audio Interface , Edit Suite- Hardware And Software Neumann Ndh 20 , Edit Suite- Hardware And Software Neumann Kh 80 Dsp Powered Studio Monitor , Edit Suite- Hardware And Software Apple Mac Mini Apple M4 Chip With 10‑Core Cpu, 10‑Core Gpu, 16‑Core Neural Engine, 32Gb Unified Memory, 512Gb Ssd Storage , Edit Suite- Hardware And Software Applecare+ For Mac Mini (M4) , Edit Suite- Hardware And Software Sonnet Rackmac Mini (2024+) - 2U Enclosure To Mount And Secure Up To Three Mac Minis In A Standard 19-Inch Rack , Edit Suite- Hardware And Software Logic Pro - Professional Music Production , Edit Suite- Hardware And Software Neumann Rime Immersive Binaural Monitoring Plug-In , Edit Suite- Hardware And Software Waves Diamond Bundle , Edit Suite- Hardware And Software Lacie 4 Tb External Hdd Thunderbolt Connected , Edit Suite- Hardware And Software Logitech Mx Keys S Performance Combo - Black (Incl Mx Master 3S, Mx Keys S & Mx Palm Rest) , Edit Suite- Hardware And Software Benq 27 Inch 1080P Fhd Ips Monitor|Height Adjustable - 3 Year Warranty (2 Display For Each System) , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Inter Connection And Storage Equipment Requirements , Storage Centralized Parking Storage For All Departments: Eonstor Gs 3000 G3 3U/16Bay,Cloud-Integrated Unified Storage, Supports Nas, San, Object Protocol And Cloud Gateway, Dual Redundant Controller Subsystem Including 4X12Gb/S Sas Exp. Ports, 4X25Gbe Ports(Sfp28) +4X Host Board Slots,4X16Gb Memory, 2X(Psu+ Fan Module), 2X(Supercap. + Flash Module), 16Xdrive Trays And 1Xrackmount Kit 32X 3.5 Hdd, Sas 12Gb/S, 22Tb, 7200Rpm 3U/16Bay Dual Redundant Controller Expansion Enclosure Including 4X 12Gb Sas Ports, 2X(Psu+Fan Module), 16Xgs Drive Trays, 2X 12G To 12G Sas Cable For Storage Or Expansion Enclosure With 12G Interface And 1Xrackmount Kit 4X 10G Base-Sr Sfp+ Transceiver, Lc, Multi-Mode 3 Years Standard Warranty , Storage Animation Department Blackmagic Cloud Store 80Tb With 1 Year Limited Manufacturers Warranty. , Storage Digital Intermediate Blackmagic Cloud Store 80Tb With 1 Year Limited Manufacturers Warranty. , Interconnection Dell Switch S4148T-On Dell Switch S4148T-On, 1U, 48 X 10Gbase-T, 4 X Qsfp28, 2 X Qsfp+, Io To Psu, 2Xpsu Dell Networking, Qsa Adapter, Qsfp+/Qsfp28 To Sfp/Sfp+/Sfp28 For Select Optics Only (Total-4Nos) Dell Networking, Transceiver, Sfp+, 10Gbe, Sr, 850Nm Wavelength (Total- 4Nos) Dell Networking Cable 100Gbe, Qsfp28 To Qsfp28, Passive Copper Direct Attach Cable, 1 Meter (Total-4Nos) Dell Networking Cable, Om4 Lc/Lc Fiber Cable, (Optics Required), 10 Meter (Total-4Nos) 5 Yrs Pro Support Nbd. , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Cinematography Requirements , Category A: Cameras & Lenses A1. Photography Kit- 1St Year Camera Body- 1St Year Sony A7R5 Body • 61Mp Full-Frame Exmor R Bsi Cmos Sensor • Bionz Xr & Ai Processing Unit • Ai-Based Real-Time Tracking Af System • 8K 24P, 4K 60P, Fhd 120P 10-Bit Video • 4K 16-Bit Raw Output; S-Log3/S-Cinetone • 9.44M-Dot Evf With 120 Fps Refresh Rate • 3.2 4-Axis Multi-Angle Touchscreen Lcd • 10 Fps Shooting With Af/Ae Tracking • 8-Stop 5-Axis Image Stabilization • Dual Cfexpress Type A/Sd Card Slots , Lcd Guard For Sony A7R5 Lcd Panel Guard , Prime Lens 1- 50Mm Sigma 50Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format, Aperture Range: F/1.4 To F/16 • One Molded Glass Aspherical Element • Three Special Low Dispersion Elements • Super Multi-Layer Coating • Floating System & Large Diameter Design • Hyper Sonic Af Motor • Rounded Nine-Blade Diaphragm • Thermally Stable Composite Material • Brass Bayonet Mount • Compatible With Sigma Usb Dock , Uv Filter For Sigma 50Mm Lens Meco 72Mm Uv Filter , Prime Lens 2 35 Mm Sigma 35Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.4 To F/16 • Five Sld Elements • One Aspherical Element, Four Hr Elements • Super Multi-Layer Coating • Stepping Motor Af System • Customizable Afl Button • Physical Aperture Ring; De-Click Switch • Rounded 11-Blade Diaphragm • Weather-Sealed Design , Uv Filter Sigma 35Mm F/1.4 Lens Meco 67Mm Uv Filter , Prime Lens 3 85 Mm Sigma 85Mm F1.4 Dg Dn (E-Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.4 To F/16 • Five Sld Elements • One Aspherical Element, Four Hr Elements • Super Multi-Layer Coating • Stepping Motor Af System • Customizable Afl Button • Physical Aperture Ring; De-Click Switch • Rounded 11-Blade Diaphragm • Weather-Sealed Desig , Uv Filter Sigma 85Mm F/1.4 Lens Meco 77Mm Uv Filter , Wide Lens 14Mm Sigma 14Mm F1.8 (E- Mount) Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.8 To F/16 • Three Fld Elements, Four Sld Elements • Four Aspherical Elements • Super Multi-Layer Coating • Hyper Sonic Af Motor, Manual Override • Rounded 9-Blade Diaphragm • Tsc Material, Brass Bayonet Mount , Zoom Lens 1 24-70Mm Sigma 24-70Mm F 2.8 Dg Dn I (E- Mount) Or Equivalent • Full-Frame | F/2.8 To F/22 • Fast & Lightweight Wide-To-Tele Zoom • Hla Autofocus • 6.7 Minimum Focusing Distance • Aperture Ring With Click & Lock Switches • Fld, Sld & Aspherical Elements • Nano Porous & Super Multilayer Coatings • Dust & Splash Resistant , Uv Filter Sigma 24-70Mm Lens Meco 82Mm Uv Filter , Zoom Lens 2 70-200Mm Sigma 70-200Mm F 2.8Mm Dg Dn Os Sport Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/1.8 To F/16 • Three Fld Elements, Four Sld Elements • Four Aspherical Elements • Super Multi-Layer Coating • Hyper Sonic Af Motor, Manual Override • Rounded 9-Blade Diaphragm • Tsc Material, Brass Bayonet Mount , Uv Filter Sigma 70-200Mm Lens Meco 82Mm Uv Filter , Telephoto Lens 150-600Mm Sigma 150-600Mm F 5-6.3 Dg Dn Os Sport Or Equivalent • Ef-Mount Lens/Full-Frame Format • Aperture Range: F/5 To F/22 • Two Fld Elements, Three Sld Elements • Super Multi-Layer Coating • Hyper Sonic Motor Af System • Os Image Stabilization • Fixed, Rotating Tripod Collar • Rounded 9-Blade Diaphragm , Uv Filter Sigma 150-600Mm Lens Meco 95Mm Uv Filter , Macro Lens 105Mm Sigma 105Mm F 2.8 Dg Dn Macro Art Or Equivalent • E-Mount Lens/Full-Frame Format • Aperture Range: F/2.8 To F/22 • One Sld Element • Super Multi-Layer Coating • 1:1 Magnification, 11.6″ Min. Focus • Hyper-Sonic Motor Af System • Custom Afl Button, Focus Limiter Switch • Physical Aperture Ring; De-Click Switch • Rounded 9-Blade Diaphragm • Weather-Sealed Desig , Uv Filter Sigma 105Mm F/2.8 Lens Meco 105Mm Uv Filter , Battery Sony Fz100 Battery Or Equivalent ( A7R5 & Fx3A) • Battery Type: High-Capacity Z-Series Rechargeable Lithium-Ion Battery • Voltage / Capacity: 7.2 Vdc / 2280 Mah (16.4 Wh) • Infolithium Feature, Dimensions: Approx. 51.7 × 38.7 × 22.7 Mm (W × H × D) • Weight: Approx. 83 G (3 Ozcompatibility: Supports Dozens Of Sony Cameras Including: O Alpha Series: A1, A1 Ii, A9, A9 Ii, A9 Iii, A7 Iii, A7R Iii, A7R Iv, A7 Iv, A7R V, A7S Iii, A7C, A7 C Ii, A7Cr, A6600, A6700 Cinema/V-Logging: Ilme-Fx3, Zv-E1, Zv-E10 Ii , Battery Charger Sony Dual Charger Bc-Zd1 (A7R5) • Battery Type: High-Capacity Z-Series Rechargeable Lithium-Ion Battery • Voltage / Capacity: 7.2 V / 2280 Mah (16.4 Wh) • Infolithium Support: Displays Remaining Battery Level On Camera Lcd • Compatibility: Sony Alpha Series (E.G., A1 Ii, A9, A7R Iv, A7 Iv, A6600), Zv Series (Zv-E1, Zv-E10 Ii) • Dimensions: Approx. 38.7 × 22.7 × 51.7 Mm (W × H × D) • Weight: Approx. 83 G (3.0 Oz) • Durability & Safety: Built-In Protection Circuitry To Prevent Overcharging/Overheating (Sony Oem) , Category A2. Video Kit Camera Body-1 (2 Year Continuity Project) Sony Fx6 • 4K Full-Frame 10.2Mp Cmos Exmor R Sensor • Dci 4K60P | Uhd 4K120 | 1080P240 • 15+ Stops Of Dynamic Range In S-Log 3 Electrical Installation • 1.3X And 2.0X Anamorphic De-Squeeze • Compact Form Weighs Less Than 2 Lb • Phase Detection Af/Face Tracking/Eye Af • Base 800-12,800 Iso / 320-409,600 Max • S-Cinetone, S-Log3, Hlg Modes • 10-Bit 4:2:2 Xavc-I/16-Bit Raw Output • Dual Cfexpress Type A/Sdxc Card Slots , Camera Body-2 (3Rd Year Song Project) Sony Fx3A • 12.1Mp Full-Frame Cmos Exmor R Sensor • Uhd 4K Up To 120 | 1080P Up To 240 • Compact Form For Cage-Free Operation • 10-Bit 4:2:2 Xavc S-I,16-Bit Raw Output • S-Cinetone/S-Log3/Hlg, 15+ Stops Dr • Detachable 2 X Xlr/Trs Adapter Handle • Phase Detection Af/Face Tracking/Eye Af • 80 To 409,600 Expanded Iso Range • Dual Cfexpress Type A/Sdxc Card Slots , Battery Sony Fz100 Battery , Panel Guard For Sony Fx3A Lcd Panel Guard , Lens Kit 18Mm, 24Mm, 35Mm, 50Mm, 85Mm, And 105Mm (2Nd And 3Rd Year) Dzo Film, Vespid Ii Prime 6-Lens Set Includes 18Mm,24Mm,35Mm,50Mm,85Mm And 105Mm • Full Frame/Vv | T1.9 To T22 Aperture • 18, 24, 35, 50, 85, And 105Mm Primes • Aspherical Element, Reduced Aberrations • 0.8 Mod Gears, 300° Focus Rotation • Cooke /I Technology Metadata • 80Mm Front Outside Diameter • Compact, Lightweight Design • Less Reflective, More Tactile Surface • Color Matched, Common Gearing And Length • Minimal Breathing And Distortion , Gimbal (3Rd Year Song Project) Rs4 Pro Combo • Lightweight Design With 10 Lb Payload • Combo With Focus Pro Motor • Oled Touchscreen With Auto Lock • 2Nd Gen Native Vertical Shooting • Automated Axis Locks • Joystick Or Bluetooth Mode Switching • Supports Wireless Transmitter, Lidar • Teflon-Coated Axes, Activetrack Pro • 13-Hour Operation Time , Battery Sony Bp-U70 Lithium Ion Battery- (Fx6) • Battery Type: Professional Lithium-Ion Battery (Bp-U Series) • Capacity: 72 Wh • Output Voltage: Approximately 14.4 V Dc Nominal (16.4 V Max) • Charging Time: Approximately 150 Minutes Using Sony Bc-U1A/U2A Charger • Compatibility: Select Sony Professional Camcorders Including Pxw-Fs7, Fx6,.. • Dimensions: 41.5 × 84.5 × 69.7 Mm (1.63 × 3.32 × 2.74 In) Weight: Approximately 450 G (15.9 Oz) • Operating Conditions: Discharge: -20 °C To +45 °C (-4 °F To +113 °F); Charge: 0 °C To +40 °C (32 °F To +104 °F) , Battery Charger Sony Dual Battery Charger Bc-U2A Batteries (Fx6) • Battery Compatibility: Supports Sony Bp-U90, Bp- U60, Bp-U60T, And Bp-U30 Lithium-Ion Batteries. • Charging Capacity: Simultaneously Charges Two Batteries, Optimizing Workflow And Reducing Downtime. • Charge Times: Bp-U90: Approximately 190 Minutes. • Ac Input: 100-240 Vac, 50/60 Hz, Suitable For Global Use. • Dc Output: 12 Vdc Via Integrated Cable, Providing 12 V Dc Power Output While Charging One Battery. • Power Output: 12 Vdc At 3 A (36 W) Via Barrel Connector. • Dimensions: 7.0 × 5.4 × 2.1 Inches (177 × 137 × 53.2 Mm). • Weight: 1.4 Lb (620 G). • Operating Temperature: 32 To 113°F (0 To 45°C). • Certifications: Compliant With Iec62368-1 Safety Standard. , Category B: Photography Lights Flash Light 1 Godox V1 Pro S Or Equivalent • Compatible With Sony Adi / P-Ttl • Output: 76Ws • Auto Zoom Control, Zoom Range: 28-105Mm • 2.4 Ghz X Wireless Radio System • Built-In Led Modeling Lamp • Tilts -7 To 120°, Rotates 330° • Round Head, Optional Magnetic Modifiers • 1.5 Sec Recycle Time, Hss Support • Includes Detachable Sub-Flash , Studio Light 1 Godox Ad 600 Pro Or Equivalent • Built-In 2.4 Ghz Wireless X System • Compatible With Most Ttl Systems • 600Ws, 1/256 To 1/1 Power Output • Lithium-Ion Battery Powered • Up To 360 Full-Power Flashes • Flash Duration: 1/220 To 1/10,100 Sec • 1/8000 Sec High-Speed Sync • 0.01-0.9 Sec Recycling Time • 38W Modeling Lamp • Stable Color Temperature Mode , Studio Light 2 Godox Qt 600 Iii Or Equivalent • 600 Ws, 5600K Color Temperature • 0.01-0.9 Sec Recycling • Flash Duration Hss: 1/26,100 Sec • Built-In Wireless X System • 32 Channels, 16 Groups • Optional X1, X2 & Xpro Transmitter • 1/256 To 1/1 Power Range • 40W Led Modeling Lamp , Softbox Octa Softbox Or Equivalent Jenie Beauty Box 105Cm , Light Stand Harison Heavy Light Stand Harison Heavy Light Stand (Set Of 2) , Strip Box Godox Strip Box 35X160 , Beauty Dish Godox W 550 Silver Eauty Dish With Grid Godox Beauty Dish W550 Sliver With Grid (Set Reflector 1 + Grid 1) , Snoot Godox Snoot , Batteries Eneloop 2000Mah Aa Rechargable Batteries (Set Of 4) , Charger Panasonic Bk 3Hcce Aa Charger , Trigger Godox It 30 Trigger With Flash For Sony Works With X Wireless Radio System Compatible With Sony Adi / P-Ttl Frequency: 2.4 Ghz Range: 328 32 Channels; 99 Ids High-Speed, 1St & 2Nd Curtain Sync Runs On Internal Rechargeable Battery Touchscreen Interface Compact & Portable Design Includes Usb-C Cable & Carry Bag , Category C: Camera Accessories (2Nd And 3Rd Year)Tripod-1 Tripod Manfrotto Mt055-X Pro 3 Or Equivalent • Versatile 3-Section Aluminum Tripod • Spreads To Just 3.5 Above The Ground • 63 Max Height • 23.2 Folded Length • Photo/Video Fluid Tripod Head • 15.4 Lb Load Capacity • All-Direction Photo Mode • Pan-And-Tilt Video Mode • Friction Control , Tripod-2 E Image 7080H • Fluid Head With Bowl Size 75Mm. • Plate With Both 1 /4And 3/8Screws , Memory Card Cf Express Type A 240Gb Or Equivalent (A7R5) & Fx6 , Memory Card Angelbird 1Tb Cf Express Type B Or Equivalent (Burano) , Memory Card Sony 480Gb Tough Card Cf Express Type A , Card Reader 1 Sony Mrw-G3 Cf E Type A Card Reader , Card Reader 2 Sony Mrw-G1 Type B Card Reader , Camera Bag Vanguard Veo 49Bf Camera Bag , Hard Case Camera Hard Case (Pelican Type) (Fx6 & Burano) Explore 7635 Hlb Hard Case For Fx6 & Burano , Camera Cage 1 Small Rig Cage For Sony A7R5 Or Equivalent • Formfitting Camera Cage • 1/4-20 & 3/8-16 Accessory Threads • Maintains Access To Cameras Hot Shoe • Arri-Style Locating Handle Included • Built-In Shoe Mounts, Anti-Twist Design • Threads To Mount Optional Accessories • Durable Aluminum Construction , Camera Cage 2 Small Rig Cage For Sony Fx6 Or Equivalent • Camera Top & Side Plates • Quick Release Baseplate • V-Mount Plate With D-Tap Power Cable • Horizontal & Vertical Mounting • 1/4-20 & 3/8-16 Accessory Threads • 3/8-16 Anti-Twist Threads • Durable Aluminum Construction • Baseplate With Folding V-Lock Plate • 15Mm Rod Clamps & 2 X 15Mm Rods , Mattee Box Mattee Box (Fx6 ) • Compact Matte Box Weighing Only 3.8 Oz • Carbon Fiber Box And Top Flag • Includes 4 X 5.65 Filter Tray • Includes 67/72/77/82-95Mm Adapter Rings • Works With Circular Filters Up To 92.5Mm • 2.2 Lb Maximum Load Capacity , Filters H&Y Nd Filters (0.3,0.6 & 0.9) & Uv Filters (Complete Set) • 0.5 To 3.0 Optical Density • Multicoating & Resistance Coating • Schott B270 Optical Glass • Fits 58-77Mm Lens Filter Threads • High-Grade 6063 Aluminum Construction • Size-Adjustable Adapter Ring • Darkens Entire Image Area • Twist To Attach In Seconds , Filters Polariser Filter (Fx6 & Burano) • Minimize Reflections And Glare • Reduces Haze And Blue Cast In Landscapes • Enhances Color And Tonal Saturation • Colorcore Water White Glass , Field Monitor Atomos Shinobi 7 4K Hdmi/Sdi Monitor • 7 1920 X 1200 Touchscreen Display • 4K60 Hdmi 2.0 In/Out, 2K60 3G-Sdi In/Out • 2200 Cd/M² Brightness • Hdmi/Sdi Cross Conversion • 2.5Mm Camera Control Port For Z Cam E2 • Dual Sony L-Series Battery Slots • Atomos; Atomhdr & 3D Lut Support • 10-Stop Dynamic Range • Supports A Variety Of Log Formats , Measuring Laser Distance Meter , Focus Chart , Colour Checker Calibrite Colorchecker Passport Video 2 (Ccppv2) , Cleaning Kit Lens Cleaning Kit (Professional) , Cables 1 Mtr Cable Hdmi To Hdmi , Cables 0.5 Mtr Cable Sdi To Sdi , Cables 5 Mtr Cable Sdi To Sdi , Cables 10 Mtr Cable Sdi To Sdi , Cables 10 Mtr Cable Hdmi To Hdmi , Cables 15 Mtr Cable Hdmi To Hdmi , Category D: Cine-Lineup Cinema Camera (2Nd Year Misc-En & Scene Project) Sony Burano 8K Digital Motion • Compact, Highly Mobile Design • Full-Frame Cmos 8.6K Sensor • 16 Stops Of Dynamic Range • In-Body Image Stabilization|E & Pl Mount • Dual-Base 800/3200 Iso Range • Electronically Variable 0.6-21Nd Filter • Phase Detection Af | Face/Eye Tracking • Full Frame & Super 35 Sensor Modes • Supports Multiple Frame Rates & Codecs • Dual Cfexpress Type B Card Slots , Monitor/ Recorder Shogun Ultra 7 & Recorder • Atomos 11, 12G-Sdi/Hdmi Conversion • 7 1920 X 1080 Touchscreen • Records Up To 8K Apple Prores Raw • Prores Raw + H.265 Dual Recording • Airglu Rf Wireless Sync, Gige, 6E Wi-Fi • 2000 Cd/M² Brightness • Arri/Canon/Red/Sony Camera Sdi Support • Avid Dnx Quicktime • Atomos Remoteview Via Subscription • Optional Ndi 4K Tx Pro Mode 1-Off , Focus System Tilta Nucleus M(Dual Motor) • 1000 Wireless Range • Two Lens Drive Motors • Motors Feature Integrated Receivers • 0.8 Mod Drive Gears • Focus, Iris, Zoom Hand Unit • Motors Daisy-Chain For Power • Right Handgrip With Focus Control • Left Handgrip With Iris And Zoom Control • Hard-Shell Waterproof Case Included , Memory Card Lexar 512Gb Cf Express Type B Card Diamond Series Or Equivalent , Battery Newell V Mount Battery (290 Watts) , Charger Newell V Mount Dual Charger , Lens Kit 8,24,35,50,75, 100Mm Zeiss Nano Prime 6 Lens Kit(18,24,35,50,75,1 00Mm) Set • 18, 24, 35, 50, 75, And 100Mm Lenses • All Lenses Cover Full-Frame Format • T1.5 To T16 Aperture Range • 12-Blade Rounded Iris • Native Lens Data Communication • Zeiss Extended Data • Lens Scale Marked In Feet • Includes Transport Case , 10 &14Mm Laowa Lenses Pl Mount (12Mm Pl Mount Lens) • Full Frame & Vv | T2.6 To T22 Aperture • Zero-D Design, Low-Distortion Optics • 117.8° Fov, 15-Blade Aperture • 16 Elements In 10 Groups • 7.9 Minimum Focusing Distance • 77Mm Filter Thread, 80Mm Front Diameter , Zoom Lens 70-200Mm Zeiss 70-200Mm Cz.2 Lens , Tripod Occnnor 1040 • Tripod: Flowtech 100 Carbon Fiber • Payload Capacity: Up To 45 Lb (20.4 Kg) • Counterbalance: Sinusoidal, Continuously Adjustable • Pan/Tilt Drag: Independent, 9+0 Positions • Tilt Range: +90° To -90° • Tripod Max Height: 60 (152.4 Cm) • Leg Sections: 3, Quick-Release Locks • Floor Spreader: Included • Handle: Pan Handle Included, Attachable Both Sides • Weight: Approx. 12.5 Kg (27.5 Lb) , Camera Cage Tilta Camera Cage For Sony Burano Advanced Kit • Modular Cage For Sony Burano • 15Mm Lws Baseplate, Side Plates • Top Plate, Top Handle, Monitor Mount • Hdmi Cable Clamp, Wi-Fi Tx Bracket • Multiple 1/4-20 & 3/8-16 Threads • Qd Sockets, Shoe Mount, Nato Rails • Side Rosette, 15Mm Rod For Monitor Mount • Aluminum & Stainless Steel Construction , Evf Bracket Rotatable Evf Bracket For Sony Burano Or Equivalent , Tool Kit Tilta Multi Functional Mini Tool Kit • Multi-Functional Mini Tool Kit • Includes 2.5Mm, 3Mm, 4Mm, 3/16 Allen Keys • Flathead & Phillips #2 Screwdrivers, T10 Torx Driver • Aluminum Alloy Frame With Stainless Steel Tools • 3/8-16 And 1/4-20 Threaded Mounts • Compact And Lightweight Design • Integrated Strap Loop For Easy Carry • Color: Titanium Gray • Compatible With Tilta Camera Cages & Support Systems • Portable For Assembly, Disassembly, And On-Set Use , Matte Box Tilta 4X5.6 Carbon Fiber Matte Box Or Equivalent , Adaptor 1 Metabones Pl To E Mount Adaptor , Dry Cabinet Andbon 300 Ltr Dry Cabinet , Light Meter 1 (Common) Sekonic Spectro Master C- 800 Light Meter • Measurement Range: 0.09-18,600 Fc (1-200,000 Lux) • Color Temperature Range: 1600-40,000K • Sensor: High-Resolution Cmos Sensor With 1Nm Increment • Ssi Support: Spectral Similarity Index For Light Matching • Display: 4.3 Color Touchscreen With 11 Display Modes • Cri/Tlci/Tm-30-15: Full Color Rendering Metrics • Flash Measurement: Selectable Shutter Speeds From 1-1/500 Sec • Power: Usb Rechargeable • Connectivity: Usb 2.0 Interface • Dimensions: 73 X 183 X 27 Mm • Weight: 230 G • Included: Carrying Case And Usb Cable , Light Meter 2 (Common) Sekonic Speed Master L858D-U Light Meter • Measuring System: Incident And Reflected Light Metering • Sensor: Spd Sensor • Measuring Range: -5 To 22.9 Ev (Iso 100) • Illuminance Range: 0.1 To 2,000,000 Lux • Iso Range: Iso 3 To Iso 13,107,200 • Shutter Speed Range: 30 Min To 1/80,000 Sec • Display: 2.7 Color Touchscreen Lcd • Flash Measurement: Flash Duration (1/40 To 1/55,500 Sec) • High-Speed Sync (Hss): Supported • Flash Analyzing Function: Yes • Spot Metering: 1° Spot Meter With Viewfinder • Rotating Lumisphere: 270° Rotation, Retractable • Radio Control Modules: Optional For Pocketwizard, Elinchrom/Phottix • Weather Resistance: All-Weather Design • Power: Rechargeable Battery • Dimensions: Approximately 73 X 183 X 27 Mm • Weight: Approximately 230 G , Cine Video Monitor Tv Logic Monitor (Professional Grade) • 1920 X 1080 Resolution Ips Lcd Screen • Composite, 3G-Sdi A/B, Hdmi & Dvi Inputs • Hlg, Pq & Pq2 Hdr Emulation Support • 1 X Composite & 1 X 3G-Sdi Output • 500 Cd/M² Brightness, 178° Viewing Angle • 3.5Mm Audio Headphone Output • Gpi & Ethernet Control • Waveform, Vectorscope, Audio Meter • Focus Assist, H/V Delay, Key Lock, Zoom • Tvlogic Color Calibration Utility & More , Category E: Studio Kit (Common ) Computer Apple Mac Studio M3 Ultra 28 Core Cpu •Apple M3 Ultra 28-Core Cpu •96Gb Unified Ram | 2Tb Ssd •60-Core Gpu | 32-Core Neural Engine •Uhs-Ii Sdxc Card Reader •Wi-Fi 6E (802.11Ax) | Bluetooth 5.3 •6 X Thunderbolt 5 •2 X Usb-A 3.2 Gen 1 | 1 X Hdmi 2.1 •1 X 10 Gigabit Ethernet Port •Macos , Software Final Cut Pro , Software Adobe Psd Annual Subsrciption , Accessories Apple Monitor 27Inch 4K Retina Display , Accessories Apple Keyboard , Accessories Apple Magic Mouse , Accessories Required Cables , Light Controlling Tablet Apple Ipad Pro •13 Ultra Retina Xdr Oled Touchscreen •2752 X 2064 Screen Resolution (264 Ppi) •Apple M4 9-Core Cpu •10-Core Gpu | 16-Core Neural Engine •512Gb Storage | 8Gb Ram •5G Lte | Wi-Fi 6E | Bluetooth 5.3 •Front & Rear 12Mp Ultra Wide Cameras •40 Gb/S Thunderbolt Connectivity •Supports Apple Pencil Pro•Ipados , Display X Lg C3/G3 Oled 65 •Display Type: Qned (Quantum Dot Nanocell Withminiled) •Screen Size: 164 Cm (65 Inches)•Resolution: 3840 X 2160 Pixels (4K Ultra Hd) •Processor: Α7 Ai Processor 4K Gen8 •Color Technology: Dynamic Qned Color With 100%Dci-P3 Coverage •Local Dimming: Advanced Local Dimming Forenhanced Contrast •Hdr Support: Hdr10, Hlg, Dolby Vision •Audio Output: 20W Rms •Audio Technologies: Ai Sound Pro (9.1.2 Channel),Dolby Atmos •Operating System: Webos 2025 With Ai Features •Remote Control: Ai Magic Remote With Ms Copilotintegration •Connectivity: Wi-Fi, Bluetooth, Hdmi, Usb, Ethernet •Voice Assistant: Built-In Google Assistant, Alexasupport •Mounting: Vesa Compatible (300 X 300 Mm) •Dimensions (W X H X D): 1456 X 840 X 29.7 Mm •Weight: 22.5 Kg , Lg 9.1.5 Sound Bar S95Tr (Latest Model) Sound Bar: • Channels & Power: 9.1.5 Configuration With 810 W Total Output And 17 Built-In Speakers •Immersive Audio: Supports Dolby Atmos, Dts:X, Andtriple- Level Spatial Sound For A Cinematic Surroundexperience •Smart Integration: Ai Room Calibration Pro, Woworchestra & Wowcast Enable Seamless Integrationwith Lg Tvs And Wireless Pairing •Connectivity: Includes Hdmi Earc, Hdmi 2.1 Input,Optical, Bluetooth 5.1, Wi-Fi, Usb, Plus Support Forchromecast, Airplay 2, Alexa, And Google Assistant •Setup: Simple Installation Via Power And Single Hdmiconnection With Wireless Rears And Sub; Ideal Formedium-Sized Rooms •Design: Sleek And Low-Profile, Approximately 49.2 ×2.5 × 5.3 Inches (Soundbar); Space-Efficient Setup. , Projector 4K Projector With Screen •Display Technology: 0.65 Dlp •Resolution: 3840 X 2160 Pixels (4K Uhd) •Brightness: 2200 Ansi Lumens •Contrast Ratio: 600,000:1 •Color Gamut: 84% Dci-P3 •Throw Ratio: 0.69-0.83:1 •Zoom: 1.2X Manual Zoom•Focus: Manual •Input Lag: 4.16 Ms (1080P @240Hz) •Hdr Support: Hdr10, Hlg •Audio Output: 5W X 2 Speakers •Audio Features: Earc, Dolby Atmos Passthrough •Operating System: Android Tv (Via Qs02 Dongle) •Streaming Support: Netflix, Youtube, Prime Video,Disney+, Hbo Max, Apple Tv+, Spotify •Connectivity: 2X Hdmi 2.0B, Usb Type-A, Rs232,Audio Out (3.5Mm Mini Jack) •Wireless Features: Wi-Fi 6, Bluetooth 5.0, Googlecast, Apple Airplay •Dimensions: 11 Cm X 30 Cm X 25 Cm •Weight: 3.1 Kg •Power Consumption: 275W (Max), 0.5W (Standby) , Movable Storage 10Tb Desktop External Hdd - Usb 3.0 For Windows And Mac , Ups 1500Va Ups , Computer Speaker 2.1 2.1 Audio Computer Output , Mega Phone Ahuja Bta 550 Wireless Bluetooth Portable 30 Watt Pa • Power Output: 30W Rms • Speaker Configuration: Single 8 Full-Range Dual-Cone Speaker With Tweeter • Microphone Inputs: Two Wired Mic Inputs (4Mv/4.7Kω), One Wireless Mic Input • Auxiliary Input: One Guitar (Aux) Input (100Mv/47Kω) • Tone Controls: Active Bass And Treble Adjustments • Digital Effects: Built-In Digital Echo • Playback Features: Mp3 Player With Bluetooth, Usb, Sd/Mmc Card Support, And Recording Capability • Remote Control: Included For Convenient Operation • Power Sources: Ac Mains, External 12V Dc, Or Built-In 11.1V 2200Mah Rechargeable Li-Ion Battery • Battery Life: Approximately 4 Hours On Battery Power • Construction: Plastic Moulded Cabinet With Trolley System For Portability • With Microphone , Safety Storage Solid Safety Storage To Store Camera With Lock Camera Safety Storage With Door And Lock (14X3X9) (Lxbxh) , Category F: Lighting Equipments , Portable Light Kit • Eight Lights With Charging Case • Output: 396 Lux At 3.3 Per Light • 2000-10,000K Cct; Rgb Color Control • 4.2 X 2.7 Panel; 2-Hour Runtime Battery • Cri 96 | Tlci 96 | Cqs 95 | Tm-30 Rf 94 • Onboard, Dmx/Rdm, Crmx & App Control • Tighter 45° Beam Angle • 0-100% Dimming, 15 Special Effects • 1/4-20 & Magnetic Mounting, Ip65-Rated • Includes Mounting Accessories & Cables , Cine Led Bulb Kit Aputure B7C Bulb Kit (8 Bulbs) • For Studio And Film/Tv Production Output: 328 Lux At 3.3 (120º, 6500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • Clamp To Baby Pin Adapter • Straight Connector Included , Panel Light 1 Aputure Nova P600 C Panel Light • For Studio & Film/Tv Production Output: 17,520 Lux At 3.3 (5600K) • 2000 To 10,000K; Rgb Color Control • 31.6 X 18.96 Panel, Ac/Dc Operation • Cri 95 | Tlci 95 | Ss1 84 | Cqs 95 • On-Board, Dmx512, Bluetooth App Control • Active Fan Cooling • With Control Box, Yoke, Mounting Clamp • Dimming: 0-100°, Plus/Minus Green Adj. • 300+ Gel Presets, 19 Special Effect , Barn Door Aputure Barndoor For P 600 Light P600Rb4 Barn Door For Aputure P600C Or Equivalent , Soft Box Aputure Softbox P 600R23 • For Studio & Film/Tv Production • Output: 98,500 Lux At 3.3 W/ Reflector • 5600K Cct • Ac Or Battery Power • Onboard, Wireless, Dmx & App Control • Art-Net & Lumenradio • Cri 96 | Tlci 96 | Cqs 94 | Ssi 72 • Active Cooling, Weather-Resistant Design • Bowens S Accessory Mount • Includes Remote, Reflector & Rolling Bag , Cine Led Light Godox M 600R Light For Studio & Film/Tv Production Output: 136,000 Lux At 3.3 W/ Reflector 1800-10,000K Cct; Full Rgb Color Control Onboard, Dmx, Crmx & App Control Art-Net & Sacn Ethernet Control Fan Cooled Bowens Mount Ip65 Rated Includes Control Box Includes Power Cable & Soft Case , Cine Light 1 Godox Tl120-K4 Light Four Lights & Remote Control For Wireless Control From Up To 164 Output: 685 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Hard Case For Wireless Control From Up To 164 Output: 685 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Hard Case , Cine Light 2 Godox Tl 60-K2 Light Two Lights & Remote Control For Wireless Control From Up To 164 Output: 421 Lux At 3.3 For Each Light 2700-6500K Cct; Rgb Mode Onboard, Wireless, Dmx & App Control Cri 96 | Tlci 98 39 Preset Special Effects Built-In Rechargeable Battery; Ac Power Retaining Clip With 1/4-20 For Mounting Includes Adapters, Clips & Bag Remote Control & Carry Case , High Power Light 1 Godox Mg 120 Arc-Biannual Rate Contract Color Light For Photo, Video, Film & Tv Production 78,800 Lux At 9.8 With Optional Fresnel 2800-6500K Color Temperature Multi-Voltage Ac Power Onboard, Dmx & Lumenradio Crmx Control Bluetooth & 2.4 Ghz Wireless Control 96 Cri, 96 Tlci Fan Cooled, 0-100% Dimming 11 Special Effects, 4 Dimming Curves Compatible With Godox G-Mount Modifiers , High Power Light 2 Godox Mg1200 R Light Compatible With Godox G-Mount Modifiers Green/Magenta Adjustments, 14 Effects Upgraded Optical Technology, Ip65 Rated 78,800 Lux At 9.8 With Optional Fresnel 2800-6500K Color Temperature Multi-Voltage Ac Power Onboard, Dmx & Lumenradio Crmx Control Bluetooth & 2.4 Ghz Wireless Control 96 Cri, 96 Tlci Fan Cooled, 0-100% Dimming 11 Special Effects, 4 Dimming Curves Compatible With Godox G-Mount Modifiers , Storm Light 1 Godox Mg4 K Arc-Biannual Rate Contract Color Light For Studio & Film/Tv Production Output: 640,000 Lux At 3.3 W/ Reflector 2800-10,000K Cct; Green/Magenta Shift Ac Power Onboard, Dmx, Crmx, Ethernet & App Improved Fan Cooling System Compatible With Godox G-Mount Modifiers Upgraded Optical Technology & Ip65 Rated 2.4 Diameter Light Source Emitter Includes Controller & Ac Power Cable , Storm Light 2 Godox Mg 6K Arc-Biannual Rate Contract Color Light For Studio & Film/Tv Production Output: 1,025,000 Lux At 3.3 (5600K) 2800-10,000K Cct; Bi-Color Mode Powered Via Ac Cable & Power Controller Onboard, Dmx, Rdm & Bluetooth Control Cri 97 | Tlci 97 Advanced Air Cooling System G-Mount-Compatible & Includes Yoke Ip65-Rated For Dust & Water Protection , Light Mat 1 Aputure Infinimat 4 X 4 Light Mat • Type: Modular Rgbww Led Light Mat • Size: 4 X 4 Ft • Color Temperature: 2000-10,000K • Color Accuracy: Cri 96, Tlci 97 • Light Engine: Rgbww • Control Box: 1600W, Ac-Powered • Mounting: Multiple Methods Supported • Included Accessories: Inflatable Softbox, Skirt, Control Grid, Head Cable (24.6), Safety Rope • Power Consumption: 800W (Maximum) • Connectivity: Bluetooth (100M Range) , Light Mat 2 Aputure Infinimat 2 X 4 • Type: Modular Rgbww Led Light Mat • Size: 2 X 4 Ft • Color Temperature: 2000-10,000K • Color Accuracy: Cri 96, Tlci 97 • Light Engine: Rgbww • Control Box: 400W, Gold Mount • Power Options: Ac Or Gold Mount Battery • Mounting: Multiple Methods Supported • Included Accessories: Inflatable Softbox, Skirt, Control Grid, Head Cable (24.6), Safety Rope • Power Consumption: 400W (Maximum) • Connectivity: Bluetooth (100M Range) , Light Bar 1 Aputure Infinibar Pb 12 4 Light Kit • Output: 617 Lux At 3.3 (120º, 7500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • 8 X 45º Light Control Grids • Flight Case And 330W Power Adapter , Light Bar 2 Aputure Infinibar Pb6 4 Light • For Studio And Film/Tv Production Output: 328 Lux At 3.3 (120º, 6500K) • 2000 To 10,000K; Rgb Color Control • 23.8 X 1.8 Panel; Ac/Dc Operation • Cri 96 | Tlci 98 | Ssi 74 | Tm-30 94 • Dmx, Crmx, And Sidus Link App Control • Passive Cooling • 2 X 1/4-20 Threads, Infinibar Rail • Clamp To Baby Pin Adapter • Straight Connector Included , Compact Light 1 Amaran F22C Light • For Studio & Film/Tv Production Output: 6420 Lux At 3.3 (5600K) 2500-7500K Cct; Hsi Color Control • 2 X 2 Mat; Ac/Dc Operation • Cri 95 | Tlci 98 | Cqs 96 • On-Board, Dmx, And Bluetooth Control • Passive Cooling For Silent Operation • 0-100% Dimming, 15 Lighting Effects • Multi-Voltage Ac, V-Mount Battery • Includes Softbox Frame, Diffusers & Grid , Compact Light 2 Godox La 300 R Light For Video Production & Vlogging Output: 94,700 Lux At 3.3 W/ Reflector 1800-10,000K Cct; Full Rgb Color Control Ac Or Optional Battery Power Onboard & App Control; Nfc Connection Cri 95 | Tlci 94 14 Lighting Effects Bowens S Accessory Mount, Black Housing Includes Reflector Includes Power Adapter , Compact Light 3 Godox La 150 R Light For Video Production & Vlogging 165W Fixture 1800-10,000K Cct; Full Rgb Color Control Ac Or Optional Battery Power Onboard & App Control; Nfc Connection Cri 95 | Tlci 94 14 Lighting Effects Bowens S Accessory Mount Includes Reflector Includes Power Adapter , Panel Light 2 Godox Ldx 100 R Light For Video Production And Vlogging Output: 4620 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 18 X 16; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Panel Light 3 Godox Ldx 50 R Light For Video Production And Vlogging Output: 2340 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 14 X 12; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Cine Light Kit Aputure Storm 80C- 3 Light Kit Or Equivalent For Video Production And Vlogging Output: 2340 Lux At 3.3 (5600K) 2500-10,000K Cct; Rgb Color Control 14 X 12; Ac/Dc Operation Cri 96 | Tlci 96 Onboard, Wireless & App Control 0-100% Dimming, 14 Lighting Effects Optional Remote Control & Barndoors Includes Diffuser Includes Power Supply & Carry Case , Professiona L Light 1 Godox P 1200 R Hard P8 / Arri Sky Panel-X 21 Or Equivalent • Type: Modular Rgbacl Led Panel • Color Temperature Range: 1,500-20,000K • Color Accuracy: Cri ≥99, Tlci ≥93 • Light Output: 16,602 Lux At 3.3 (1M) • Panel Size: 2X1 (29.1 X 13.3 Inches) • Pixel Zones: 8 Independent Zones • Control Options: Wired (Dmx-512), Wireless (Bluetooth Via Lico App, Lumenradio) • Cooling: Passive/Active With Ip66 Rating • Power Supply: Integrated Psu; Daisy-Chainable With Other Skypanel X Units • Mounting: Tool-Less Frame With Quick-Lock System • Compatibility: All S60-C Accessories Via Optional Adapter • Included Accessories: X21 Dome, Manual Yoke, Mains Cable , Hard Light Godox P 1200 R Hard / X21 Hard Light For Arri Sky Panel Or Equivalent P8 X21 Hard Light For Arri Sky Panel Or Equivalent , High Power Light Godox P 1200 R Hard P 8 For Studio & Film/Tv Production Output: 129,200 Lux At 3.3 (5600K) 1800-10,000K Cct; Rgb Color Control 29.2 X 15.2 Panel | Ac Power Cri 96 | Tlci 98 Onboard, Dmx/Rdm, Crmx & App Control Improved Fan Cooling System Flicker-Free Operation Ip65-Rated Weather Resistance Includes Yoke & Ac Power Cable , Dido Lights Godox Ms 600R 2K / Dido Lights Light , Category G: Light Accessories Spotlight Mount 1 Godox Vsa-26 K Spotlight Attachment Projectionlight Kit , Spotlight Mount 2 Godox Vsa-36K Kit Spotlight Attachment Kit , Iris 18 X Godox Vsa-Id Spotlight Mount 36 , Gobo Kit Godox Vsa-Gs1 Gobo Kit , Fresnel 1 Godox Fls 5 Fresnel , Fresnel 2 Godox Fls 10 Fresnel , Barn Door Godox Lb-02 , Light Dome 1 Godox Qr-P 90 T Light Dome , Light Dome 2 Godox S 65 T Light Dome Mini , Light Dome 3 Godox Qr-P 150 T Light Dome , Light Dome Godox Cs 85D Lantern 120 , Light Dome Godox Gp 5 Light Dome , Lantern Godox Cs 85 D Lantern , Reflector Kit Reflector Kit (For 1200X & 1000C) Or Equivalent , Cf12 Fresnel Godox Fls 10 Fresnel , Spotlight Max 1 Godox Gp 36 K Spotlight , Spotlight Max 2 Spotlight Max 50 (For 1200X,1000C,Xt 26) Or Equivalent , Iris Max 18 Godox Gp-Id Iris , Gobo Kit Godox Gobo Kit Godox Gp-Gs1,2,3,4,5 , F14 Fresnel Godox Gf 14 Fresnel , Beam Kit Storm Parallel Beam 70 Kit With Flight Case Or Equivalent , Cf16 Fresnel Cf16 Fresnel With Flight Case Or Equivalent , Stand 1 Dearkol Mfe 5800 (Expandable Up To 17Ft Height & 62Kg Payload) Or Equivalent , Stand 2 Dearkol Mfd 6000 (Expandable Up To 20Ft And 82Kg Payload) Or Equivalent , Soft Box Godox P 1200 Rh Do Softbox , Mounting Rig Godox P 1200 Rh Ad Mounting Rig , Lights Dimmer 5K Dimmer , Skimmer Cloth 10X10 Skimmer Cloth , 12 X12 Skimmer Cloth , 10X10 Black Cloth , 12 X12 Black Cloth , 10X10 Green Cloth , 12 X12 Green Cloth , Backgroung For Photography , Safety Storage For Lights Camera Safety Storage With Door And Lock (14X3X9) (Lxbxh) Stainless Steel 0.8Mm, Thickness (Jindal Ss) , Category H: Light Grip Equipments C Stand Godox 270Cs Stand , Par Stand 1 Par Stand Double Height , Par Stand 2 Par Stand Triple Height Or Equivalent , Black Flags 1 4X4 Black Flags Or Equivalent , Black Flags 2 2X1 Black Flags Or Equivalent , Empty Frames 4X4 Empty Frames Or Equivalent , Boom Rods Boom Rods (Various Sizes) Or Equivalent Boom Rods : Stand Height 6Ft To 10Ft, Extension Rod 5 Ft To 10Ft. , Arm Rods Arm Rods (Various Sizes) Or Equivalent , L Rods L Rods (Various Sizes) Or Equivalent , Sand Bag Sand Bag (Professional Grade) Or Equivalent , Skimmer Frame 1 6X6 Skimmer Frames Or Equivalent , Skimmer Frame 2 10X10 Skimmer Frames Or Equivalent , Skimmer Frame 3 12X12 Skimmer Frames Or Equivalent , Grid 1 Honey Comb Grid 6X6 Or Equivalent , Grid 1 Honey Comb Grid 10X10 Or Equivalent , Grid 1 Honey Comb Grid 12X12 Or Equivalent , Loop Boards Loop Boards (Various Sizes) Or Equivalent Solid Wooden Loop Boards (Various Sizes) 20Mtrs 6Pin Socket 2Nos With Led Indicator And A Tripper-15 Nos; 10Mtrs Board With 6Pin Socket 4 Nos With Switch, Led Indicator And A Tripper- 10 Nos; And 20Mtrs Board 6Pin Socket 6Nos With Switch, Led Indicator And A Tripper-5 Nos. , Track System Track & Trolley Full Kit 40Feet Length Manuall 150 Bowl Height 100Kg Capacity With Head , Slider Slider 10Ft Full Kit Or Equivalent , Low Base Stands Low Base Stands , Stand For 100 Bowl Head , Stand For 150 Bowl Head , Cutter Stand , Grip Heads Grip Heads (Professional Grade) , Reflector Board Reflectors 4X4 Board , Low Board , Apple Box Apple Box Setup (Complete Set) Apple Box Setup 20X12X8, 20X12X4, 20X12X2 ,20X12X1 (Complete Set) , Stool Setup Stool Setup 1 Feet , Stool Setup Stool Setup 2 Feet , King Pole- Wall To Wall Mount King Pole (6Ft To 12Ft) , Light Clamps Light Clamps (Various Sizes) , Hydraulic Stand Hydraulic/Windup Stand , Category I: Television Production , Video Camera Sony Hx Z 200 Camera , Mixer Yamaha Mg10X Mixing Console Audio Mixer - Xlr Input/Output, Phono Jack, Level Meter , Recorder Zoom H8 Recorder , Tripod Small Rig Ad80 Carbon Tripod Model No:4163 , Mic And Accessories Sennheiser Lapal Microphone With Cable , Mic And Accessories Rode Boom Pole , Mic And Accessories Rode Ntg4 Mic , Mic And Accessories Rode Blimp , Cables Monitoring Head Phone, Video/Audio Cables And Connectors , Mac Imac, Apple M4 Chip 10-Core Cpu With 4 Performance Cores And 6 Efficiency Cores 10-Core Gpu Hardware-Accelerated Ray Tracing 16- Core Neural Engine 120Gb/S Memory Bandwidth, 512Gb Ssd, 24Gb Unified Memory, 60.96 Cm (24″) 4.5K Retina Display 4480X2520 Resolution At 218 Pixels Per Inch With Support For 1 Billion Colours, Keyboard & Mouse , Cost For Installation, Commissioning And Integration Of All Component / Equipment And Comprehensive Onsite Warranty For 36 Months , Manpower Deployment , Cost For Deployment Of System Administrator For One (1) Year
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
12.
Power #10591948 Price Bid
tender for WORK OF REPLACEMENT OF EXISTING 100 MVA 220 / 132 KV TRANSFORMER (EMCO MAKE) WITH NEW 160 MVA 220 / 132 KV TRANSFORMER (TAL MAKE) AND OTHER ASSOCIATED WORKS AT 220 K.V. SUB STATION KURSI ROAD UNDER E.T.D. - II, LUCKNOW Sl. No. Item Description 1 Following Works are to be carried out at 220 K.V. Sub Station Kursi Road, Lucknow for replacement of existing 100 MVA 220 / 132 KV Transformer (EMCO make) by new 160 MVA 220 / 132 KV Transformer (TAL make) alongwith associated works against Increasing Capacity including all cost of men, T&P, Crane, 6 - 12 KL / Hr. capacity Centrifuging Machine with Operator, Carriage Vehicle etc. to complete the job satisfactorily as per direction of site Engineer : 2 Draining of Oil from 100 MVA EMCO make Transformer at 220 KV Sub Station Kursi Road into 209 Liter Capacity Oil Drums. 3 Dismantling of existing 120 KV LAs alongwith associated structures instailed in 100 MVA 220/132 KV Transformer Bay after due cutting of earthing, opening of jumpers etc. (1 Job per L.A. with structure). 4 Complete dismantling of all the water & air pipe lines, pipe supports etc. of Emulsifire Systern around the 100 MVA 220/132KV Transformer alongwith Shifting & Stacking of all the dismantled items at safe storage place at the Sub Station. 5 Opening of HV & LV side Jumpers, Removal of Neutral & Main Tank Earthing, Opening of Control / Power Cable Connections of 100 MVA 220/132 KV Transformer including opening of connections of associated OLTC & Marshalling Box. 6 Complete safe Dismantling of the accessories of 100 MVA 220/132 KV Transformer including opening of Jumpers, removal of earthing, opening of Cable connections, Removal of Conservator Tank, Pipe Lines, Bushings, Cooling Fans & Pumps, Marshaling Box, Radiators after Draining of Radiator Oil in empty Drums then fixing of blanking plates on the radiators, pipe lines, conservator tank turret etc. (Suitable Blanking Plate including Bolts & Nuts as required if not available at substation, shall be provided/arranged by the Contractor.) 7 Safe Shifting & proper Stacking at storage place of all the dismantled accessories of 100 MVA 220/132 KV Transformer i.e. Conservator Tank, Pipe Lines, Bushings, Cooling Fans & Pumps, Marshaling Box, Radiators, Headers, A Frame etc. and T/F Oil Drums at the safe storage place at the Sub Station. 8 Proper packing of HV/LV neutral bushings of the dismantled 100 MVA 220/132 KV Transformer in separate wooden cases / crates of the bushings after proper wrapping of bushing with polythene sheet alongwith reparing of wooden cases, to be provided by contractor. 9 (A) Shifting of Main Tank of the dismantled 100 MVA (EMCO make) 220/132 KV Transformer from the Plinth up to 20 Meter distance including turning of Tank, as required. 10 (B) Additional Shifting of the tank of above transformer upto 200 Meter distance. (01 Job for every 5 Meter and / or part there of) 11 Dismantling and shifting of existing 100 MVA TF RTCC panel from ACDB room including opening connection of control cables , identifying cables for future connection & shifting RTCC panel at place of storage as per instructions of supervising engineer (SDO/JE) 12 (A) Shifting of Main Tank of the new 160 MVA (TAL make) 220/132 KV Transformer to its Plinth from Place of Unloading up to 20 Meter distance including turning of Tank, as required. 13 (B) Additional Shifting of the tank of above transformer upto 120 Meter distance. (01 Job for every 5 Meter and / or part there of) 14 Complete erection of the 160 MVA (TAL make) Transformer including its radiators, conservator tank, turrets, connecting pipe lines, HV / HV / neutral bushings, cooling fans, OLTC drive mechanism box, marshalling box, OTI, WTI, capillary tubes etc. 15 Supply of dry Nitrogen gas having DEW point (-60°C to -65°C) under vacuum fro top valve of the transformer upto pressure of 2PSI (as per tehcnical norms of Transformer) and maintaning the same in the main tank for 12 Hrs. including cost of nitrogen gas and nitrogen gas filling device for dry cycle. 16 Create the vacuum inside the T/F tank & maintain it for 24 Hrs. dry air cycle of T/F creating vacuum inside the main tank of T/F, maintaning it for 24 Hrs. then filling of dry air bearing dew point (-60°C to -65°C) for 24 Hrs. And repeating the same till the PPM value of main tank is achieved below 05 PPM filling the oil step by step in 160 MVA T/F. 17 Centrifuging of completed T/F oil in T/F oil tank by connecting centrifuging machine to be provided by the contractor and taking the BDV,PPM & IR values of the oil & TF bushings periodically till the required value in achieved as per direction of Supervising Engineer (Centrifuging machine, BDV & PPM machine, megger shall be arranged by the contractor). After centrifuging ,DGA test of oil sample is to be carried out. 18 Carriage of oil tank of 20KL (01 Nos) capacity from 220 KV S/S Chinhat to 220 KV S/S Kursi Road distance upto 20 KM including loading and unloading at respective place and after work completion. Carriage of oil tanks of 20 KL (01 Nos.) from 220 K.V. Sub Station Kursi Road to 220 KV S/S Chinhat. 19 Delta earthing of 160 MVA Transformer consisting of fabrication of delta set with 03 Nos. 40 mm / 33 mm dia size 03 Mtr. ling electrode, its placing inside ground and connecting all the these electrode with 75x10mm M.S. Flat 700 mm deep and connecting the same with earthmat at two places. Also connecting delta to earth mat of substation at two places as per drawing provided by site engineer from UPPTCL. The work also to be done for painting the welding joint in black colour below earth level and green colour above ground level in two coats. (MS Rods & MS Flat will be provided by the department free of cost). 20 Erection of 132 KV LAs including erection of associated ALP structures, earthing of the LAs with existing M.S. Flat and jumpering with ACSR Zebra Conductors to connect with 132 KV Jack Bus with the help of ACSR Zebra Conductor, associated terminal connectors, P.G. Clamps etc. (01 Job per LA with associated structure). 21 Jumpering of HV side bushing of the 160 MVA transformer to connect with HV side CTs through 220 KV LAs with ACSR Zebra Conductor, associated terminal connectors etc. 22 Jumpering of LV side bushing of the 160 MVA transformer to connect with LV side CTs through 132 KV LAs with ACSR Zebra Conductor, associated terminal connectors, PG Clamps etc. 23 Laying of following size control cables from C&R panel to marshalling box/equipment/ junction box etc in switch yard for new 160 MVA T/F as per cable schedule along with saddling at every 750mm distance with MS saddles of size 25x3 sq mmincluding carriage of cable drums from store to laying site and shifting back remaoning drumsto store after work completion. The work shall also include interconnection of control cables with marshalling box , OLTC panel to RTCC panel, ferruling, dressing of cables and other associated works for satisfactory completion of job as per technical specificatons: 24 2C x 2.5 sq mm 25 4C x 2.5 sq mm 26 6C x 2.5 sq mm 27 10C x 2.5 sq mm 28 Erection of new 160 MVA TF RTCC panel including shifting from place of storage to ACDB room as per directions of site engineer (SDO/JE). 29 Earthing of main tank, marshalling box, drive mechanism, Transformer neutral, , RTCC panel etc of new 160 MVA Transformer with 50 x 6 mm and 75 x 10 mm size MS flats, its jointing with already existing earth mats/ deltas including necessary modification in existing support for earthing of neutral bushing for its earthing work and then painting of earthing strips as per technical specifications. 30 Making termination / connection of the control & power cables as per new cable schedule of 160 MVA Transformer, RTCC Panel, control & relay panel, cooling fans, pumps, marshalling box. OLTC, driving mechanism etc. dressing & binding of additional control cables, if required as per site requirement alongwith making necessary holes in the gland plate / box, wherever required including providing & fixing of cable glands of appropriate sizes providing of ferrules etc. 31 Testing of new 160 MVA Transformer 32 Conducting test of 160 MVA T/F (M/s TAL make) by arranging appropriate equipments for following items :-i. DGA test of Transformer oil & Water Content Test of Transformer oil 33 Conductioning test of 160 MVA T/F (M/s TAL make) by arranging appropriate equipments for following items :-1. WRM-01 No.2. Tan Delta-02 No. (Pre-erection and post-erection)3. Turret CT Ratio. Polarity, Knee Point continuity & I.R. Test 34 Work of re-erection, hydraulic testing, & commissioning of water spraying and fire detection mulsifyre system comprising of following detailed pipe lines with all cost of men, material, T&P etc required for the job as per details below: 35 Supply and installation of 80 mm dia B-class GI pipe for support with round clamp at top & flanges at bottom as per specifications including grouting and painting etc. 36 Providing, laying, installation , testing and commissioning of new 50 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 37 Providing, laying, installation , testing and commissioning of new 40 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 38 Providing, laying, installation , testing and commissioning of new 25 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 39 Supply, installation of HV nozzle projector HD make. 40 Supply, installation , testing of QB detector 41 Laying, installation, testing & commissioning of old G.I. Pipe B Class including cutting, welding etc. and providing suitable Flangs alongwith necessary fitting viz bends, elbow, tees, reducer, gasket etc.:- 42 25 mm dia. G.I. Pipe 43 50 mm dia. G.I. Pipe 44 65 mm dia. G.I. Pipe 45 80 mm dia. G.I. Pipe 46 100 mm dia. G.I. Pipe 47 150 mm dia. G.I. Pipe 48 Installation of HV nozzle projector 49 Installation of HV HD Fire detector 50 Erection, hydraulic testing & commissioning of complete mulsifyre system by installation of high velocity water spraying & fire detection system on 160 MVA 220/132KV TF by using old dismantled/newly laid additional pipe lines including providing of new gaskets/packings of required sizes along with necessary welding / jointing and earthing of pipe supports after re-construction of damaged RCC foundation for pipr supports. 51 Painting of above installed water spraying & fire detection system on 160 MVA 220/132KV TF in 02 coats of synthetic enamel paint after due application of 01 coat of red oxide primer after removal of old paint by rubbing with emery paper. The water pipe lines shall be painted in P.O. red color , Air pipe lines in sky blue color,Pipe supports in black color, earthing strips in Bus green color. 52 Electrical Safety processing fees needed for providing all relvant safety clearance documents from electrical safety department for energisation of the above commissioned 160 MVA Transformer and its accessories (Note: The amount payable is actual rate of challan or quoted rate, whichever is lower) 53 160 MVA Power Transformer 54 All LA (220/132 KV) associated with newly commissioned 160 MVA Transformer 55 HT inspection fees 56 Work of re-erection, hydraulic testing, & commissioning of water spraying and fire detection mulsifyre system on 132/33 KV 63 MVA M/s Atlanta make Transformer, comprising of following detailed pipe lines with all cost of men, material, T&P etc required for the job as per details below: 57 Providing, laying, installation , testing and commissioning of new 150 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 58 Supply and installation of 80 mm dia B-class GI pipe for support with round clamp at top & flanges at bottom as per specifications including grouting and painting etc. 59 Providing, laying, installation , testing and commissioning of new 40 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 60 Providing, laying, installation , testing and commissioning of new 25 mm dia B class GI pipe with elbows, Tees, sockets, flanges, bends etc including its painting and connection to already dismantled existing pipe lines ( as may be required) 61 Supply, installation of HV nozzle projector HD make. 62 Supply, installation , testing of QB fire detector 63 Replacement of diaphragm along with re-installation of quick opening flood, deluge valve HD make 150NB as per maximum working pressure 10kg/sq mtr of deluge valve system. 64 Erection, hydraulic testing & commissioning of complete mulsifyre system by installation of high velocity water spraying & fire detection system on 63 MVA 132/33 KV TF by using old dismantled/newly laid additional pipe lines including providing of new gaskets/packings of required sizes along with necessary welding / jointing and earthing of pipe supports after re-construction of damaged RCC foundation for pipe supports. 65 Painting of above installed water spraying & fire detection system on 63 MVA 132/33 KV TF in 02 coats of synthetic enamel paint after due application of 01 coat of red oxide primer after removal of old paint by rubbing with emery paper. The water pipe lines shall be painted in P.O. red color , Air pipe lines in sky blue color,Pipe supports in black color, earthing strips in Bus green color. 66 Following works including Providing of materials are to be carried out at 220 KV S/S Kursi Road Lucknow for Proper Lighting arrangement along the 160 MVA Transformer bay and other crucial places in switchyard with all cost of men, materials ,T&P etc . Except Cables Which shall be Provided by the Department as per direction of Supervising Engineer . 67 Providing of Lighting Junction Box of size of 280 mm x 150 mm made of 16 SWG M.S. B.P. Sheet & Painted with smoke Grey colour synthetic enamel Paint, duly fitted with 1 No 6 Amp. S.P. M.C.B. on Anodised M.S. Channel ,1 No Bakelite Fuse Fitting with 6 Amp. ,Capacity NS 6 type HRC Fuse,01 No . Copper Neutral Link ,Bakelite terminal strip of 4 Nos. terminals,Cable Glands suitable for 2C /4C x 2.5 Sq. mm size incoming /outgoingControl cable etc.& fixing on the GI Structure at designated height with the help of suitable duly fabricated M.S. Bracket Clamps and Due earthung of the Junction Box including Cable Terminations. 68 Providing & Fixing of G.I. S.L. Pole Bracket duly made of 40 mm dia B class 1.20 Meter long M.S. Pipe of (ID 35 mm& OD 40 mm) and bent at one end by quarter circle in 1.0 mtr. At an angle of 30 deg for fixing of 150 watt LED street Light Luminaries Fittings with the help of MS Bracket Clamps of suitable size for fixing on G.I. column structure at designated place. 69 Provinding & Fixing of 150 Watt LED Street Light Luminaries Fittings of PHILIPS/ CROMPTON / HAVELLS/ BAJAJ Make in Single Piece die cast aliminium Alloy Housing with Pot Optics Reflector & Toughed Clear Glass Cover with Frame for Lamp Compartment including Cable Termination . 70 Cable laying & Termination- 71 Laying of following size PVC insulated Copper Control cable from LT ACDB Cubical to Various Junction Boxes below ground level in PVC Conduit pipe (Provided by the contractor ) after due excavation ,back filling etc. including all labour ,PVC Pipe etc. required for proper completion of the work . 72 2 C x 2.5 Sq mm 73 Laying of Control cables between LT Lightinig Junction box & LED Street Light Fittings along GI Structure including necessary clamping with suitable M.S. street clamp with Proper Dressing . 74 Providing & fixing of Post Lamp Glow Light of latest design complete with white color defuser suitable for installation at main entrance/garden/lawn lighting. 75 Fabrication of protective net for radiators of 132/33 KV Transformers, control room glass window, JE room glass window and associated works: 76 Providing, fabrication and fixing of protection net in front of radiator of Trasformer, made of MS channel, angle, mesh and cross section type net. Size of protection net , including all cost of men and material- 77 132/33 KV 100 MVA Transformer M/s Atlanta make, size 2500x5000 sq mm for radiator and 6100x2500 sq mm for marshalling box (total area 27.75 sq mtr) 78 132/33 KV 63 MVA Transformer M/s Atlanta make, size 6000x2500 sq mtr for radiator 79 JE Room glass window 80 Control room glass window 81 Providing, fabrication and grouting of MS Channelin front of radiator by concreting for support of protection net by welding or nut & bolt as required , including all cost of men and material: 82 132/33 KV 100 MVA Transformer M/s Atlanta make, 4500 mm size at 4 places ( Total length 18 mtr ) 83 132/33 KV 63 MVA Transformer M/s Atlanta make, 4500 mm size at 2 places ( Total length 9 mtr) 84 JE Room glass window, 3000 mm size at 2 places ( total length 6 mtr) 85 Control room glass window , 3000 mm size at 4 places ( Total length 12 mtr) 86 Fabrication and fixing of 03 no. P.I. on the top of front protection for extra support of LV side conductor including all cost of men & material: 87 132/33 KV 100 MVA Transformer M/s Atlanta make 88 132/33 KV 63 MVA Transformer M/s Atlanta make 89 Spray/ brush Painting of following equipments/items painting includes one coat of red oxide and two coats of Green/Red colour good quality Asian/Burger/Nerolac make paint after through rubbing and cleaning of old scale of painted surface to remove rust,dust etc. 90 Earthing strip 75 x 10 mm in green Colour 91 Earthing strip 50 x 06 mm in green Colour 92 Switchyard lighting JB in smoke grey color 93 220KV CT/CVT in smoke grey color 94 220KV SF6 CB in smoke grey color 95 220KV & 132KV Isolator operating box in smoke grey color 96 132KV CT/CVT in smoke grey color 97 33 KV Isolator Operating Box in smoke grey colour. 98 33 KV CT & PT Junction Box in smoke grey colour. 99 Work and supply related to work of installation of CCTV camera at crucial places of substation for protection from theft and surveillance of store and switchyard equipment 100 Providing and fixing of outdoor Static (Bullet)IP 2MPCCTV Network camera having resolution 1920x1080,full HD 1080p video, 140 dB, WDR ,3d DNR smart heater ,Image sensor 1/2.8, progressive Scan CMOS,Shutter time 1/100000 Sec. Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 100-120 Meter Model No DS-2CD4A25FWDIZ(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make. 101 Providing and fixing of Full HDoutdoor Dome IP 2MPCCTV camera having resolution 1920x1080,full HD 1080p video, digital WDR ,3d DNR smart heater ,Image sensor 1/2.8, progressive Scan CMOS,Day and Night IR cut filter with auto Switch weather proof IP 67 protection,IR range 50-70 Meter Model No DS-2CD432F-I(Z)(H)(S) of Hikvision make or equivalent model of BOSCH/CAME make. 102 Providing and fixing of 16 Channel Embedded plug and play NVR having 16 channel,2TB HD, SupportH.264+& h.264, 6 MP ,Integrated 16 Port PoE, HDMI, resolution 1920x1080p upto 2 SATA Interface, Model No7614NI-E2/16P of Hikvision make or equivalent model of BOSCH/CAME make. 103 Providing and Fixing of 32 Full HD LED TV (model No KDL-32W700B 80cm) of Sony make 104 Supply and fixxing of 3KVA on -Line UPS with isolation transformersuitable for single phaseAC power supply and single phase outputAC ,floor mounted type with 120 minut power backup APC make (modal No.SURTD3000XLI) or equivalent modelof standerd make. 105 Providing & fixing of 4TB Hard Disk of seagate make for storing the servilance data. 106 Providing & fixing of power supply board 24 Volt DC/24Amp AC of standard make. 107 Porviding & fixing of Power Over Eathernet (POE) Switch (08 Port), 10/1000 MBPS of D-Link make model No. DGS-1210-10P (08 Port) 10/100/1000 MBPS 108 Providing & laying 40 mm dia size HDPE pipe of standard make for laying of power supply cable/OFC/CAT-6 Data cable as per requirement. 109 Providing & laying of RG-60 3 GHZ Co-axial optical fiber cable of Fonolex/Standard make for CCTV wiring. 110 Providing & laying of Cat-6 Data Cable of D-link make for connecting PTZ Cameras to NVR. 111 Providing & laying of 3 Core 1.5 Sq. mm Multi Strnad Copper Wire Power Cable of Finolex/Standard make as per IS alongwith providing & fixing of Junction Boxes whereever required. 112 Providing of Computer Table of Godrej make as per sample. 113 Earthing of Cameras & NVR as per technical specification (01 Job each) 114 Work related to supply & installation of Fire Detection System operating on the basis of feedback by Smoke Detectors in BCUs, Store, ACDB room, Battery room, & office building at 220 KV substation Kursi Road Lucknow 115 Supply & installation of 08-12 Zone Conventional fire detection and fire alarm system with power supply arrangement. (Make compatible with IS: 2189:1999 tested by ERTL (N) and System Sensor (Agni suraksha/ Agni devices/ daksh OR equivalent). 116 Supply & installation of Manual Call Point A breakable glass cover fixed in such a way that the actuating push button is kept depressed as long as the glass is intact and released when the glass is broken. A small steel hammer shall be attached to the assembly with a steel chain to facilitate breaking of glass. The manual call points shall be suitable for surface or fully / partly recessed mounting. 5mm high red painting/printed word IN CASE OF FIRE BREAK GLASS shall be provided on the front face. The manual call point shall be compatible with all conventional control panels. (Make Agni Suraksha (ASES) / Safeway Equivalent Agni Devices). 117 Electronic hooter 11 dB/24V DC with strobe (ABS-V) The enclosure should be 1.5 mm thickness duly painted and marked FIRE ALARM. All hooters shall produce a similar sound and shall maintain the same during their operation. (Make Agni Suraksha (ASES) / Safeway Equivalent/ Agni Devices). 118 Providing & Fixing of lonisation type Smoke Detectors The detector while sensitive to all type of smokes will be insensitive to ambient lights, air drafts, and changes within the operating temperature and voltage ranges. The Detector shall meet the requirements of either EN 54/ FM/ UL or LPC and shall be specifically approved by FM/ UL/LPCB. Apollo / System Sensor /Edward/Bosch. 119 Providing & Fixing of Heat Detectors (for the area like Battery room, AC plant area, DG room, etc) It is a combination of rate of rise and fixed temperature principle using thermistor and with automatic compensation for changes of ambient conditions. The thermal detectors are tested and approved to EN54 part 5 (2000) Class A1R Apollo / System Sensor / Edward / Bosch/Agni suraksha. 120 Providing & Fixing of Response Indicator Lamp assembly consisting of lamp holder and lamp shall be suitable for mounting on walls, partition etc. The housing shall be suitable for surface/flush mounting of 1.5mm thick sheet steel and the facia 3mm acrylic mounted outside a cabin, and directly connected to the detector inside the cabin. In normal circumstances the lamp should flicker but in the event the detector inside the cabin senses a fire, the lamp should glow. 121 Supply and laying 2x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections.PVC insulated copper conductor wires shall confirm to IS: 694. And, PVC insulated copper conductor armoured cables should confirm to IS: 1554 (part-1). Make National/Plaza/Kalinga or any other standard make 122 Supply and laying 4x1.5sqmm PVC insulated and sheathed stranded copper wire. Wiring for fire alarm system in general shall comply with IS: 2189 and IS: 732 amended up to date. The detectors shall be wired by ISI marked 1.5 sq mm PVC insulated stranded FRLS copper conductor wires of 1100 volts grade as required and desired on site. Crimping type of lugs are also included in the rates of laying wires and its connections. Make National/Plaza/Kalinga or any other standard make 123 Supply and installation of SMF Batteries with suitable rating as required for 24 Hours backup from Exide / Standard / Amco Prestolite/any other standard make. 124 Signage with backlit facility for Control building marking for various Fire / emergency exit points. 125 Supply and laying of Ms/PVC conduit pipe 25mm as per Requirement of site. 126 Provising, fixing & installation of different types of boards i.e. Glow Sign Board, Shutdown Notice Board, Instruction Board etc as detailed bwlow, to be carried out at 220KV substation Kursi Road Lucknow as per specifications and directions of supervising engineer: 127 Providing, fixing and installation of Glow Sign Board of size 10 ft x 6 ft for substation single line diagram to be fixed in control room building of the substtaion. The Glow Sign Board should be illuminated using sufficient number of LED tube lights. The board shall be made of ACrilic sheet and shall be provided with back support frame & fixing arrangement. 128 Name plates made of 2mm thick Aluminium Sheet coveredwith 3 M HIP retro reflective sheet of following size with details / name written by 3M HIP Retro reflective sheet as per prescribed color scheme to be fixed with the help of nuts & bolts at already installed equipment structure in switchyardwith all cost of plates, nut-bolts, misc materials, T&Pand labour as per specificatins & directions of supervising engineer: 129 300mm x200mm 130 450mm x 250mm 131 500mm x 250mm 132 R,Y,B phase plate sets consisting of one plate of red,, yellow, blue colors in each set & plates of dia 250mm duly made of 2mm thick aluminium sheet with face to be fully covered in red , yellow, blue phase colors in 3 M HIP retro reflective sheetand the phase plate set to be fixed with the help of suitable size G.I. bolts, nuts on already installed equipment structure etc at the substation.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
13.
Housing Urban and Rular Development #10555683 Price Bid
Servicing And Routine Maintenance Of Air Conditioners , Servicing Of Existing Installed Wtac/ Stac/Cgac Of 1 . 5 Tr & 2 . 0 Tr Capacity Ac And Water Coolers Of 80/150/250 Lph , Checking For Unit , Inspection Greasing , Oiling Etc . I/C Chemical Cleaning Of Condensing & Cooling Coil With High Pressure Pump Changing The Air Filter , Checked & Tightening All Electric Connections , Testing The Machine Etc . As Reqd . ( Tentative Service Period From 10 . 03 . 2021 To 30 . 03 . 2021 ) . , Supply & Charging R-22/410/407/32/134A Gas In The Existing Wtac/Stac / Of 1 . 5/2 . 0 Tr Unit I/C Pressure Testing , Flushing The System And Gas Charging Complete As Reqd . , Replacement Of Following Capacity Compressor In The Existing Wtac/Split Ac Making Copper Pipe Connection , Brazing Pressure Testing And Supplying And Charging Refrigerant Gas I/C Cutting The Copper Piping Dismantling Of The Old Compressor Complete As Reqd . ( Make:- Hitachi/ Whirlpool/ Kirloskar As Per Compatibility Of Air Conditioner ) , A ) 1 . 5 Tr , B ) 2 . 0 Tr , Providing & Replacement Wtac/Stac/ Ctac Fan Motor Capacity 1/4 To 1/8 Hp Including Dismantling The Burned Motor From The Existing Unit & Fixing Of New Motor , Making Connections Testing , Commissioning Etc . As Reqd . ( Make:- Lg/ Voltas/ As Per Compatibility Of Air Conditioner ) , Supplying & Fixing 25 Mm Diameter Pvc Heavy Duty Pipe For Drainage In The Existing Split Type Ac Unit With Supporting Clamps Etc . Complete As Reqd . ( Make :- Polycab/ Finolex/ Akg ) , Supplying , Fixing , Testing And Commissioning Of Interconnecting Copper Refrigerant Pipe Of Size Of 1/4 Discharge Side & 1/2 Suction Side From Indoor Unit To Outdoor Unit Alongwith Closed Cell Nitrite Rubber Insulation As Per Specification Properly Supported With Clamps Etc . Complete As Reqd . ( Make :- Mandev / Malaysia ) , Providing And Fixing Of ( 3X2 . 5 Sq . Mm ) Pvc Insulated & Pvc Sheathed Copper Conductor Circular Flexible Cable And Commissioning Etc . As Required . ( Make:-Finolex/Rr Kable/ Skytone/ Havells/ Polycab/Ralison / Bencab ) , Relocating Of Existing Installed Stac Of 1 . 5 Tr & 2 . 0 Tr Capacity With Outdoor Unit , From Its Location To Another Location , I/C Testing & Commissioning Etc . As Required . , Supplying And Replacement Of Following Defective Spare Parts In The Existing Ac Unit I/C Connection Testing Etc . Complete As Required . ( Dismantle Material Retained By Contractor ) ( Make:- Shiva/ Tibkon/ Shrada/ Havells ) , A ) Running Capacitor - 36 Mfd/45 Mfd , B ) Starting Capacitor- 80/100 Mfd , Repair Of Damaged Pcb Of Indoor & Outdoor Unit Including Tightening The Loose Connection , Testing The Machine Etc . As Reqd . , Supplying & Replacement Of Remote Control System With Remote ( Wireless/With Wire Remote ) In The Existing Installed Window/Split Type Ac I/C All Interconnection , Testing And Commissioning Complete As Reqd . ( L . G/ Azure/ Voltas Or Different Suitable Make ) , Supplying And Replacement Of Wornout/Defective Copper Condenser Coil With Same Size Of Design Suitable For Following Capacity Split Type Ac Out Door Unit I/C Breezing The All Copper Pipe With All Distribution Joints Of Make Sure The Connection With Capillary Tube Linking Dryer Duly Proper Etc Pressure Testing Leak Detection , Vaccumizing The Unit , Gas Charging Etc Complete As Reqd . ( Dismantle Retaine By Contractor ) , A ) 1 . 5Tr Capacity , Providing , Fixing Suction / Discharge Valve Of 5/8 Inch And 1/4 Inch Of Split Air Conditioner Unit Including Brazing The Valve With Compressor Suction And Discharge Line Etc . As Required . , Supplying & Replacement Of Following Capacity Split Type Ac Indoor Unit I/C Testing , Commissioning Etc . As Required . , A ) 1 . 5 Tr , B ) 2 . 0 Tr , Supplying And Replacement Of Following Capacity Split Type Ac Outdoor Unit . , A ) 1 . 5 Tr , B ) 2 . 0 Tr , Comprehensive & Routine Maintenance Of Wtac/Stac/ Unit & Water Cooler I/C Attending Day To Day Complaints From 9Am To 5Pm & Rectifying The Defects , Supplying & Replacement Of Worn Out Parts Such As Capacitors , Starting Relays , Selector Switches , Sleeves , Knobs , Front Grills Connectors Etc . Which Required To Be Replace During Routine Maintenance & Monthly Cleaning Of Filters Etc . ( Replacement Of Compressor , Condenser Fan , Blower , Fan/Blower Motor , Coils , Main Lead , Gas Charging Etc . Not Covered Under Routine Maintenance ) Complete As Per Terms & Condition And Direction Of Engineer-In-Charge . ( 102 Nos . X 7 Months=714Nos . ) ( Note:-The Comprehensive Maintenance Will Start After 01Month Of Servicing Of Acs ) , Credit For Dismantle Material . , A ) Worn Out 1 . 5/2 . 0 Tr Capacity Compressor , B ) Burn Out Fan Motor 1 , 1/2 , 1/4 , 1/8 , , C ) Refrigerant Copper Pipe , D ) Worn Out Condenser Coil , E ) Running/Starting Capacitors , F ) Split Type Ac Indoor Unit 1 . 5/2 . 0Tr , G ) Split Type Ac Outdoor Unit 10 . 5/2 . 0Tr , H ) Suction /Discharge Valve
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
14.
Housing Urban and Rular Development #10555657 Price Bid
repair maintenance of AC Units (WTAC / STAC), Water Coolers in Meera Bai Institute of Technology Maharani Bagh New Delhi. (SH:-Servicing & Routine Maintenance of Air Conditioners) (67Nos). (2) RMO AC Units (WTAC / STAC), Water Coolers in Circle Office South East & South at Visheswarya Flyover Sukhdev Vihar, New Delhi. (SH:-Servicing & Routine Maintenance of Air Conditioners)(08Nos) , servicing of existing installed wtac / stac / cgac of 1 . 5 tr & 2 . 0 tr capacity ac & water coolers of 80 / 150 / 250 lph , checking for unit , inspection greasing , oiling etc . i / c chemical cleaning of condensing & cooling coil with high pressure pump changing the air filter , checked & tightening all electric connections , testing the machine etc . as reqd . ( tentative service period from 10 . 03 . 21 to 30 . 03 . 21 ) . , supply & charging r-22 / 410 / 407 / 32 / 134a gas in the existing wtac / stac / of 1 . 5 / 2 . 0 tr unit i / c pressure testing , flushing the system and gas charging complete as reqd . , replacement of following capacity compressor in the existing wtac / split ac making copper pipe connection , brazing pressure testing and supplying and charging refrigerant gas i / c cutting the copper piping dismantling of the old compressor complete as reqd . ( make:- hitachi / whirlpool / kirloskar as per compatibility of air conditioner ) , a ) 1 . 5 tr , b ) 2 . 0 tr , providing & replacement wtac / stac / ctac fan motor capacity 1 / 4 to 1 / 8 hp including dismantling the burned motor from the existing unit & fixing of new motor , making connections testing , commissioning etc . as reqd . ( make:- lg / voltas / as per compatibility of air conditioner ) , supplying & fixing 25 mm diameter pvc heavy duty pipe for drainage in the existing split type ac unit with supporting clamps etc . complete as reqd . ( make :- polycab / finolex / akg ) , supplying , fixing , testing & commissioning of interconnecting copper refrigerant pipe of size of 1 / 4 discharge side & 1 / 2 suction side from indoor unit to outdoor unit alongwith closed cell nitrite rubber insulation as per specification properly supported with clamps etc . complete as reqd . ( make :- mandev / malaysia ) , providing and fixing of ( 3x2 . 5 sq . mm ) pvc insulated & pvc sheathed copper conductor circular flexible cable and commissioning etc . as required . ( make:-finolex / rr kable / skytone / havells / polycab / ralison / bencab ) , relocating of existing installed stac of 1 . 5 tr & 2 . 0 tr capacity with outdoor unit , from its location to another location , i / c testing & commissioning etc . as required . , supplying and replacement of following defective spare parts in the existing ac unit i / c connection testing etc . complete as required . ( dismantle material retained by contractor ) ( make:- shiva / tibkon / shrada / havells ) , a ) running capacitor - 36 mfd / 45 mfd , b ) starting capacitor- 80 / 100 mfd , repair of damaged pcb of indoor & outdoor unit including tightening the loose connection , testing the machine etc . as reqd . , supplying & replacement of remote control system with remote ( wireless / with wire remote ) in the existing installed window / split type ac i / c all interconnection , testing & commissioning complete as reqd . ( l . g / azure / voltas or different suitable make ) , supplying & replacement of wornout / defective copper condenser coil with same size of design suitable for following capacity split type ac outdoor unit i / c breezing the all copper pipe with all distribution joints of make sure the connection with capillary tube linking dryer duly proper etc pressure testing leak detection , vaccumizing the unit , gas charging etc complete as reqd . ( dismantle retained by contractor ) , a ) 1 . 5tr capacity , providing , fixing suction / discharge valve of 5 / 8 inch and 1 / 4 inch of split air conditioner unit including brazing the valve with compressor suction and discharge line etc . as required . , supplying & replacement of following capacity split type ac indoor unit i / c testing , commissioning etc . as required . , a ) 1 . 5 tr , b ) 2 . 0 tr , supplying & replacement of following capacity split type ac outdoor unit . , a ) 1 . 5 tr , b ) 2 . 0 tr , comprehensive & routine maintenance of wtac / stac / unit and water cooler i / c attending day to day complaints from 9am to 5pm and rectifying the defects , supplying & replacement of worn out parts such as capacitors , starting relays , selector switches , sleeves , knobs , front grills connectors etc . which required to be replace during routine maintenance & monthly cleaning of filters etc . ( replacement of compressor , condenser fan , blower , fan / blower motor , coils , main lead , gas charging etc . not covered under routine maintenance ) complete as per terms & condition and direction of engineer-in-charge . ( 75 nos . x 7 months= 525nos ) ( note:- the comprehensive maintenance will start after 15days of servicing of acs ) , credit for dismantle material . , a ) worn out 1 . 5 / 2 . 0 tr capacity compressor , b ) burn out fan motor 1 , 1 / 2 , 1 / 4 , 1 / 8 , , c ) refrigerant copper pipe , d ) worn out condenser coil , e ) running / starting capacitors , f ) split type ac indoor unit 1 . 5 / 2 . 0tr , g ) split type ac outdoor unit 10 . 5 / 2 . 0tr , h ) suction / discharge valve
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
15.
Housing Urban and Rular Development #10520727 Price Bid
Tender For Servicing And Routine Maintenance Of Air Conditioners , Servicing Of Existing Installed Wtac / Stac Of 1 . 5 Tr & 2 . 0 Tr Capacity Ac And Water Coolers Of 80 / 150 / 250 Lph , Checking For Unit , Inspection Greasing , Oiling Etc . I / C Chemical Cleaning Of Condensing & Cooling Coil With High Pressure Pump Changing The Air Filter , Checked & Tightening All Electric Connections , Testing The Machine Etc . As Reqd . , Supply & Charging Refrigerant Gas In The Existing Wtac / Stac / Of 1 . 5 / 2 . 0 Tr Unit I / C Pressure Testing , Flushing The System And Gas Charging Complete As Reqd . , Replacement Of Following Capacity Compressor In The Existing Wtac / Split Ac Making Copper Pipe Connection , Brazing Pressure Testing And Supplying And Charging Refrigerant Gas I / C Cutting The Copper Piping Dismantling Of The Old Compressor Complete As Reqd . ( Make:- Hitachi / Whirlpool / Kirloskar As Per Compatibility Of Air Conditioner ) , 1 . 5 Tr , 2 . 0 Tr , Providing & Replacement Wtac / Stac / Ctac Fan Motor Capacity 1 / 4 To 1 / 8 Hp Including Dismantling The Burned Motor From The Existing Unit & Fixing Of New Motor , Making Connections Testing , Commissioning Etc . As Reqd . ( Make:- Lg / Voltas / As Per Compatibility Of Air Conditioner ) , Providing & Replacement Wtac / Stac / Fan Motor Capacity 1 / 2 To 1 Hp Including Dismantling The Old And Worn Out Motor From The Existing Unit And Fixing Of New Motor , Making Connections Testing , Commissioning Etc . As Reqd . ( Make:- Lg / Voltas / As Per Compatibility Of Air Conditioner ) , Supplying & Fixing 25 Mm Diameter Pvc Heavy Duty Pipe For Drainage In The Existing Split Type Ac Unit With Supporting Clamps Etc . Complete As Reqd . ( Make :- Polycab / Finolex / Akg ) , Supplying , Fixing , Testing & Commissioning Of Interconnecting Copper Refrigerant Pipe Of Size Of 1 / 4 Discharge Side & 1 / 2 Suction Side From Indoor Unit To Outdoor Unit Alongwith Closed Cell Nitrite Rubber Insulation As Per Specification Properly Supported With Clamps Etc . Complete As Reqd . ( Make :- Mandev / Malaysia ) , Providing & Fixing Of ( 3X2 . 5 Sq . Mm ) Pvc Insulated & Pvc Sheathed Copper Conductor Circular Flexible Cable & Commissioning Etc . As Required . ( Make:-Finolex / Rr Kable / Skytone / Havells / Polycab / Ralison / Bencab ) , Relocating Of Existing Installed Stac Of 1 . 5 Tr & 2 . 0 Tr Capacity With Outdoor Unit , From Its Location To Another Location , I / C Testing & Commissioning Etc . As Required . , Supplying & Replacement Of Following Defective Spare Parts In The Existing Ac Unit I / C Connection Testing Etc . Complete As Required . ( Dismantle Material Retained By Contractor ) ( Make:-Shiva / Tibkon / Shrada / Havells ) , Running Capacitor - 36 Mfd / 45 Mfd , Starting Capacitor- 80 / 100 Mfd , Repair Of Damaged Pcb Of Indoor & Outdoor Unit Including Tightening The Loose Connection , Testing The Machine Etc . As Reqd . , Supplying & Replacement Of Remote Control System With Remote ( Wireless / With Wire Remote ) In The Existing Installed Window / Split Type Ac I / C All Interconnection , Testing And Commissioning Complete As Reqd . ( L . G / Azure / Voltas Or Different Suitable Make ) , Supplying & Replacement Of Wornout / Defective Copper Condenser Coil With Same Size Of Design Suitable For Following Capacity Split Type Ac Out Door Unit I / C Breezing The All Copper Pipe With All Distribution Joints Of Make Sure The Connection With Capillary Tube Linking Dryer Duly Proper Etc Pressure Testing Leak Detection , Vaccumizing The Unit , Gas Charging Etc Complete As Reqd . ( Dismantle Retain By Contractor ) , A ) 1 . 5Tr Capacity , Supplying And Replacement Of Cooling Coil Suitable For 1 . 5 Ton / 2 Ton Wtac Unit I / C Cutting The Existing Condenser From The Existing Unit Rewelding New Condenser Pressure Testing Of Leakage I / C Gas Charging Complete As Reqd . , Comprehensive & Routine Maintenance Of Wtac / Stac / Unit & Water Cooler I / C Attending Day To Day Complaints From 9Am To 5Pm And Rectifying The Defects , Supplying & Replacement Of Worn Out Parts Such As Capacitors , Starting Relays , Selector Switches , Sleeves , Knobs , Front Grills Connectors Etc . Which Required To Be Replace During Routine Maintenance & Monthly Cleaning Of Filters Etc . ( Replacement Of Compressor , Condenser Fan , Blower , Fan / Blower Motor , Coils , Main Lead , Gas Charging Etc . Not Covered Under Routine Maintenance ) Complete As Per Terms & Condition And Direction Of Engineer-In-Charge . ( 79 Nos . X 8 Months= 632Nos . ) ( Note:- The Comprehensive Maintenance Will Start After 01 Month Of Servicing Of Acs ) , Credit For Dismantle Material , Worn Out 1 . 5 / 2 . 0 Tr Capacity Compressor , Burn Out Fan Motor 1 , 1 / 2 , 1 / 4 , 1 / 8 , , Refrigerant Copper Pipe , Worn Out Condenser Coil , Worn Out Cooling Coil , Running / Starting Capacitors
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
16.
Housing Urban and Rular Development #10520723 Price Bid
TENDER FOR Servicing And Routine Maintenance Of Air Conditioners , servicing of existing installed wtac/ stac of 1 . 5 tr & 2 . 0 tr capacity ac & water coolers of 80/150/250 lph , checking for unit , inspection greasing , oiling etc . i/c chemical cleaning of condensing & cooling coil with high pressure pump changing the air filter , checked & tightening all electric connections , testing the machine etc . as reqd . , supply & charging refrigerant gas in the existing wtac/stac / of 1 . 5/2 . 0 tr unit i/c pressure testing , flushing the system and gas charging complete as reqd . , replacement of following capacity compressor in the existing wtac/split ac making copper pipe connection , brazing pressure testing and supplying and charging refrigerant gas i/c cutting the copper piping dismantling of the old compressor complete as reqd . ( make:- hitachi/ whirlpool/ kirloskar as per compatibility of air conditioner ) , 1 . 5 tr , 2 . 0 tr , providing & replacement wtac/stac/ ctac fan motor capacity 1/4 to 1/8 hp including dismantling the burned motor from the existing unit & fixing of new motor , making connections testing , commissioning etc . as reqd . ( make:- lg/ voltas/ as per compatibility of air conditioner ) , providing & replacement wtac/stac/ fan motor capacity 1/2 to 1 hp including dismantling the old and worn out motor from the existing unit and fixing of new motor , making connections testing , commissioning etc . as reqd . ( make:- lg/ voltas/ as per compatibility of air conditioner ) , supplying & fixing 25 mm diameter pvc heavy duty pipe for drainage in the existing split type ac unit with supporting clamps etc . complete as reqd . ( make :- polycab/ finolex/ akg ) , supplying , fixing , testing and commissioning of interconnecting copper refrigerant pipe of size of 1/4 discharge side & 1/2 suction side from indoor unit to outdoor unit alongwith closed cell nitrite rubber insulation as per specification properly supported with clamps etc . complete as reqd . ( make :- mandev / malaysia ) , providing & fixing of ( 3x2 . 5 sq . mm ) pvc insulated & pvc sheathed copper conductor circular flexible cable & commissioning etc . as required . ( make:-finolex/rr kable/ skytone/havells/polycab/ralison/ bencab ) , relocating of existing installed stac of 1 . 5 tr & 2 . 0 tr capacity with outdoor unit , from its location to another location , i/c testing & commissioning etc . as required . , supplying & replacement of following defective spare parts in the existing ac unit i/c connection testing etc . complete as required . ( dismantle material retained by contractor ) ( make:- shiva/ tibkon/ shrada/ havells ) , running capacitor - 36 mfd . /45 mfd . , starting capacitor- 80/100 mfd . , repair of damaged pcb of indoor & outdoor unit including tightening the loose connection , testing the machine etc . as reqd . , supplying & replacement of remote control system with remote ( wireless/with wire remote ) in the existing installed window/split type ac i/c all interconnection , testing and commissioning complete as reqd . ( l . g/ azure/ voltas or different suitable make ) , supplying & replacement of wornout/defective copper condenser coil with same size of design suitable for following capacity split type ac out door unit i/c breezing the all copper pipe with all distribution joints of make sure the connection with capillary tube linking dryer duly proper etc pressure testing leak detection , vaccumizing the unit , gas charging etc complete as reqd . ( dismantle retain by contractor ) , a ) 1 . 5tr capacity , supplying and replacement of cooling coil suitable for 1 . 5 ton/2 ton wtac unit i/c cutting the existing condenser from the existing unit rewelding new condenser pressure testing of leakage i/c gas charging complete as reqd . , comprehensive & routine maintenance of wtac/stac/ unit & water cooler i/c attending day to day complaints from 9am to 5pm & rectifying the defects , supplying & replacement of worn out parts such as capacitors , starting relays , selector switches , sleeves , knobs , front grills connectors etc . which required to be replace during routine maintenance & monthly cleaning of filters etc . ( replacement of compressor , condenser fan , blower , fan/blower motor , coils , main lead , gas charging etc . not covered under routine maintenance ) complete as per terms & condition and direction of engineer-in-charge . ( 106 nos . x 8 months= 848nos . ) ( note:- the comprehensive maintenance will start after 01 month of servicing of acs ) , credit for dismantle material , worn out 1 . 5/2 . 0 tr capacity compressor , burn out fan motor 1 , 1/2 , 1/4 , 1/8 , , refrigerant copper pipe , worn out condenser coil , worn out coiling coil , running/starting capacitors
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
17.
Health and Family Welfare #10433257 Price Bid
Supply Of Machine, Equipment And Others , List Of Machine And Equipments , Laproscopic Hd Camera Brand - Karl Storz/Conmed/Olympus Technical Specification Resolution: 1920X1200 Pixes / 1900X1000 Pixes Cable Length: 300 Cm , Ultrasonic Harmonic Scalpel Brand - Johnson Technical Specification Dimensions: (Hxwxd) 5.3 14.5X15.2 Voltage: 100-240 Vac Frequency: 50/60 Hz Rated Current: 3 Amp , Ultrasonic Harmonic Scalpel Brand - Valley Lab Technical Specification Macrobipolar/Bipolar: 473 Khz Sinusoid, 100% Duty Cycle. Seal: 473 Khz Sinusoid Pulsed , Hand Instruments For Laproscopy Brand- Karl Storz/ Olympus Technical Specification I) Veress Needle: It Should Be With Spring Action Blunt Style -12 Cm: 1 No 10 Cm: 1 No 8 Cm: 1 No Ii) Trocar And Cannula:10 Mm: 2 Nos 7 Mm: 1 No. 5 Mm 6 Nos It Should Consists Of Trocar, Cannula With Insufflation And Multifunctional Valve And Must Have Pyramidal Tip. Iii) Reducer/Reduction Sleeve 5 Mm. 1 No Iv) Telescopes: 10 Mm- 0°- 1 Nos -30? - 1 Nos5 Mm-30? 1 Nos Rigid Rod Lens System Provides Good Resolution And The Better Dept Perception. It Should Have Uniform Image Brightness And Autoclavable. The 300 Forward Oblique Angle And Permits For Greater Latitude For Viewing Underlying Areas Under Difficult Anatomical Conditions. V) Suction Cannula: 10 Mm - 1 No 5 Mm -1 Nos Vi) Laparoscopic Scissors: Curved (Monopolar Metzenbaum Dissector 5Mm Diameter): 1 Nos Straight (Bipolar):1 Nosperitoneal Scissor: 1 Nosvii) Unipolar Forceps (Hook & Spatula): 2 Nos Viii) Bipolar Forceps : 2 Nos Ix) Atraumatic Forceps: Maryland Dissector Forceps: : 2 Nos. Fenestrated Forceps: : 2 Nos. X) Needle Holder (Flat Jaw) With Handle : 2Nos Xi) Monopolar Cable (Reusable):1 Nos. Xii) Bipolar Cable (Reusable): 1 Nos Xiii) Allis (Double Row Of Teeth) Grasper: 1 Nosxiv) Aspiration Needle: 1 Nos. Xv) Reducer/ Reduction Sleeve (5Mm): 1 Nos Xvi) Grasping Forceps (Toothed & Rachet 5Mm): 2 Nos Xvii) Laparoscopic Knot Pusher: 1 Nos Xviii) Clip Applicator (Reusable): 5Mm -: 1 Nos : 10 Mm: Ino Xix) Uterine Manipulator: 1 Nos Xx) Clips( Medium & Large) Xxi) Drilling Needle:1 Nos Xxii) Infiltration Needle: 1 Nos Xxiii) Biopsy Forceps (Toothed Punch Biopsy): 1 Nos Xxiv) Myoma Fixation Screw: 2 Nos Xxv) Tissue Morcellator With Base Unit & Accessories: 1 Nos , Dual Wavelenght Laser Brand- Zeiss Technical Specification Laser Type: Diode, Semiconductor Wavelength : 1470Nm+635Nm Max Power: 15 Watts/1470Nm+5Mv/635 Aiming Beam : 635Nm/1, 4Mw Max Or 515Nm/2, 5Mw Max Operation Mode : Continuous Or Modulated Pulsed Time : 0.05Ms-1000Ms Beam Delivery : Sma905 Connector Optic Fiber Compatible : Optic Fibers Having A Core From 200Um To 1000Um, Na=0.22~0.48 Beam Emission Initiation : Footswitch Controller :Microprocessor Display : 10.1 Ips With Touch Panel Medical Approved Cooling :Internal, Air And Thermoelectric Cooling Power Supply Of The Laser: Dc 24V/8.33A From The Separate Ac Power Supply Of Ac Adapter : Single Phase 100-240Va; 50-60Hz, Max 90W Ac Adapterdc 24V/8.33A Medical Approved Laser Dimensions: 27Cm*24,5Cm X 9Cm Laser Weight: 2.75Kg Laser Case Dimensions : 53Cm X 38Cm X 23Cm Weight Of Laser With Cases : 9Kg Environmental Conditions During Work : From +10 To 24°C Degree, Relative Humidity From 30% Up To 60% Cass Of Medical Deviceiib Laser Safety Class 4 Electric Safety Class I Type B Housing Protection Degree Ip20b , Hd Camera Set Brand- Karl Storz/ Olympus Technical Specification (I) Hopkinsa® Forward-Oblique Telescope 30A, Diameter 4 Mm, Length 30 Cm, A Utoclavable, Fiber Optic Light Transmission Incorporated, Color Code Ed :1 Nos (Ii) Telecam C3 : 1 Nos (Iii) Image1 St™ Hx One-Chip Full Hd Camera Head, 50/60 Hz, Fixed Focus, Prog Ressive Scan, Soakable, Gas-And Plasmasterilizable, Focal Length F = 16 Mm, 2 Freely Programmable Camera Head Buttons, For Use With Image1 X-Link Tc301, Tele Pack + And Tp101 : 1 Nos (Iv) Medical Grade Surgical Monitor - Fhd : 1Nos (V) Cold Light Fountain Power Led 175 Scb, With Integrated Karl Storz-Scb, High-Performance Led And One Karl Storz Light Outlet, Power Supply 11-240 Vac, 50/60 Hz Including: 400 A Mains Cord 20090170 Scb Connecti G Cable : 1Nos (Vi) Fiber Optic Light Cable, With Straight Connector, Extremely Heat-Resi Stant, With Safety Lock, Diameter 4. 8 Mm, Length 250 Cm :1 Nos , T U R P Set Brand-Olympus Technical Specification (1) Cystoscope-Urethroscope Sheath, 22 Fr :1 Nos (2) Telescope Bridge, With 1 Lockable Channel, For Use With Cystoscope Sheaths : 1Nos (3) Working Element, E 1 Working Element (Also For Use With Optical Urethrotome) 2 Cutting Loops2 Coagulat Ng Electrodes 2 High Frequency Cords 1 Protection Tube . The Thumb Support Is Movable. In Rest Position Th Electrode Is Inside The Sheath.:1 Nos (4) Resectoscope Sheath, 26 Fr, 1 Nos (5) Schmiedt Visual Obturator, : 1 Nos (6) Cutting Loop Angled, 24/26 Fr., Units Of 6 : 1Nos Ellik Evacuator:1 Nos (7)Urethrotome Sheath, 21 Fr. Urethrotome Sheath And 2 Luer-Lock Cones.:1 Nos (8) Obturator, For Urethrotome Sheath, 21 Fr.1 Nos Sachse Cold Knife, Straight, Not To Be Used With Hf Current This Artic Le Is Only Available In Units Of 6 :1 Nos , Flexible Cystoscope Brand-Olympus Technical Specification Cysto-Urethro-Fiberscope, With Contrapositive Deflection Mechanism, De Flection Of Distal Tip 210°/140, Direction Of View 0°, Angle Of View 10, Working Channel Inner Diameter 7 Fr., Sheath Size 15.5 Fr., Worki G Length 37 ??, Consisting Of: 11272 Cu1 Cystourethro-Fiberscope 2767 A Case 27023 Fe Grasping Forceps 27023 Ze Biopsy Forceps 13242 Xl Lea Age Tester 11025 E Pressure Compensation Cap 27651 B Cleaning Brush 27 14 Y Lueradaptor , Echocardiography Brand-Ge Healthcare/ Philips / Siemens Healthcare/Bpl Technical Specification A) 2D, M-Mode, Colour M-Mode B) Colour Flow Doppler Imaging C) Fully Steerable Pulsed Doppler D) Fully Steerabie Continuous Wave Recall E) Digital Cine Replay Of All Imaging And Doppler Modalities. F) On Screen Cine Storage & Image Recall G) Digital Image Storage And Patient Archive With True Scanner Frame Rates. H) Full Measurement And Analysis Capabilities. Both On Line And Offline Preferable. I) Imaging Frequencies From 1 Mhz To 15 Mhz J) Review Of Stored Ultrasound Images. K) User Adjustable B Colorization Maps, Gain Settings, Colour Doppler Baseline, Angle Correction And Other Important Parameters With Live/Frozen/Archived Images/Loops. , 12 Lead Ecg Machine (Brand - Bpl/Maestros) Technical Specification Electrocardiograph Should Have Capability Of Recording 12-Lead Ecg And Should Have The Following Features: 1. Should Have Simultaneous Acquisition Of 12 Leads 2. Should Have A Display To Preview The Ecg Waveform Before Printing 3. Should Have 7 Inch Or More Display With High Resolution Screen 4. Should Be Compact, Portable And Easy To Operate 5. Should Have Keyboard For Manual Entry Of Patient Data 6. Should Have Provision For Providing Hospital Name On The Printed Record7. Should Work On Li-Ion Battery8. Should Have A Frequency Response Of 0.01-300 Hz 9. Should Have Sampling Frequency Of 15,000 Hz Or More10. The Device Should Weigh Less Than 5.5 Kgs With Battery11. Should Have A Special Arrhythmia Triggered Mode Of Printing12. Should Have Pacemaker Detection Facility 13. Should Be Able To Record On Different Modes Of Sensitivity: 2.5,5,10,20 Mm/Mv & Agc14. Should Have Different Recording Speeds: 5, 10, 12.5, 25 And 50 Mm/Sec15. Should Have Different Filters Available For Smoothing Of Waveform16. Should Have Ac Filter, Emg Filter: 25 Or 35 Or 45 Hz Or Off17. Should Have Anti-Drift Filter18. Should Have Different Print Formats: 3/6/12, 3X4 With Rhythm Leads, 6X2, 12X119. Should Have A Large Storage Of 700 Ecgs Or More20. In Case Of Error In Lead Connections, The Machine Should Display The Change In Color Of Particular Lead.21. Should Be Able Transfer Data Directly In Pdf Format To Usb22. Should Be Able To Printout Records On Thermal Paper As Well Z-Fold23. Should Have Facility Of Printing In Automatic/ Manual/ Rhythm/ R-R Mode Of Printing24. Should Have Facility For Interpretations And Measurements25. Should Provide Detailed Printout Of Patient Data26. Should Have Paper Of Minimum Width Of 210Mm27. Should Have The Capability To Generate Any Number Of Ecg Copies For Distribution28. Should Be Able To Connect To Pc 29. Should Be Able To Operate To A Maximum Of 4 Hours On A Newly Charged Battery30. Should Have Direct External Printer Connectivity31. The Unit Should Be Portable And Should Be Able To Carry With Help Of A Handle.32. The Product Should Be Ce Certified33. The Manufacturer Should Be Iso Certified34. The Device Should Be Provided With Standard Accessories:A) Ecg Cable (Adult)-1 Nob) Gel Bottle- 1 Noc) Chest Electrodes (Set Of 6)- 1 Nod) Limb Electrodes (Set Of 4)- 1 Noe) Z-Fold Paper - 1 Packf) User Manual-1 No , Multipara Patient Monitor(Brand - Drager/Penlon/ Bpl) Technical Specifications For Multipara Monitor 1. Multiparameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,(Massimo),Nibp (Suntech) Temperature.3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have12-Inchcolor Lcd Display.5. Should Have Dual Modes Of Operation: Rotary Knob.6. Should Display 7 Waveforms Or More7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen.8. Ecg: Should Be Able To Monitor Ecg Through 5-Lead Patient Cab Should Have Manual St Analysis Window ,Should Detect 20 Arrhythmias And Generate Alarms. , The Priority Of Arrhythmia Alarms Can Be Configurable, Should Measure Pvc &Pac Should Be Able To Monitor Heart Rate From 10-300 Bpm Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etcshould Have Pacemaker Detection Facility Respiration: Measurement Range Of 0 To 150 Breaths Per Minshould Have Gain Selection: ×0.25, ×1, ×2, ×4 Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S Should Have Apnea Detection Facility Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10 Spo2: Should Have Massimo Technologyshould Have Measurement Range Of 0~100 % Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: Must Be Of Suntech Medicaltechnology For Clinical-Grade Blood Pressure Measurement Have Auto, Manual, And Stat Modes Of Operation For Nibp. Should Have A Measuring Range Of 0-280 Mmhg Should Have 2 Channels For Temperature Monitoring Should Have Data Storage Capabilities:72 Hours Of Trend Data Storage. , Bp Machine Brand - Pagoda/ Omron/ Platinium/ Dr Trust/Bpl Technical Specification Should Be Able To Measure Blood Pressure And Pulse Rate In Adult As Well As Pediatric Patients. Should Be Based On Oscillometric Measurement Technology, Using Dynamic Linear Deflation Method. Should Have Backlight Lcd Display With Easy To View Readings In Dim Light. Pressuremeasurement Range Should Be 60 To 250Mm Hg Systolic, And 40 To 200Mm Hg Diastolic. Pressure Display Accuracy Of +/- 3 To 5 Mm Hg Pulse Rate Measurement Range Of 40 To 200 Per Minute Pulse Measurement Accuracy Of Within 5% Should Include Ac Adapter (Input Range 100-240V And Output Voltage Dc 6V), Preferably With Rechargeable Battery (3.6V To 4.8V, 1900 To 2400Mah) Cuff (22 To 32 Cm Size) Should Be Supplied With Standard Adult Size Single Button Operation For Start And Stop Functions With Auto-Inflation Of Blood Pressure Cuff. , Ventilator Brand - Drager/Bpl/Medisys Technical Specification 1. The Ventilator Should Be High-Endventilator Suitable For Ventilating To Adult And Pediatric Application. Should Have Advanced Microprocessor Control System With Individual Selection Of Various Ventilation Parameters. 2. The Unit Should Be With Altitude Compensation For Volume And Btps Correction For Monitoring3. The Unit Should Be Of Wall Independent Gas Delivery System. Demonstration Of The Equipment Is A Must Demonstration Of The Equipment Is A Must4. Should Have Facility For Invasive And Non-Invasive Ventilation;5. The Ventilator Should Have 12” Or More Lcd Screen With Touch Facility For Display Of Waveforms. Should Have Brightness Modes Like Day/Night-Mode. The Real Time Display Of All Parameters/Waveforms Should Be Clearly Visible From All Angles6. Should Have Modes Of Ventilation Equipped With Newer Modes Of Ventilation:A) Assist/ Controlb) Volume Control Modes: Vcv, Vc-Simv, Plvc) Pressure Control Modes: Pcv, Pc-Simv, Bi-Level, Bilevel-St, Pc-Aprvd) Spontaneous Ventilation Modes: Psv, Cpap, Bilevel /Similar, Bilevel St / Similare) Prvc/Pcv-Vg/Dynamic Bilevel/Or Its Equivalent Modef) Closed Looplung Protective Mode- Asv/Nava/Wobov/Alpv/Smart Care (At Least 1 Of The Mentioned Mode Is Mandatory)G) Should Have Pav (Proportional Assist Ventilation) / Pps (Proportional Pressure Support)/ Paps (Proportional Adaptive Pressure Support)H) Cpr (Resuscitation Mode),I)Niv In All Pressure Modes7. Hfot /Nasal Cpap Breathing Therapy Should Be Capable Of Adjusting The Range Up To 60Lpm8 A) Apnea Backup Ventilation In All Modes8 B) It Should Have Weaning Analyzer Tools : Sat & Sbt9. Should Have In-Built Nebulizer With Capability To Deliver Fine Particle Size Of To Be Used In Line10. Should Have Facility To Measure And Display The Following Parameters:A) Airway Pressure (Peak & Mean)B) Tidal Volume (Inspired & Expired)C) Minute Volume (Expired)D) Spontaneous Minute Volumee) Total Frequencyf) Fio2 Dynamicg) Intrinsic Peep, V Trap & Time Constant (Rcexp)H) Resistance & Compliance11. Automatic Compliance And Leakage Compensation For Circuit And Et Tube 12. Should Have Facility Of Logbook, For Events And Alarms With Date & Time 13. Should Have Following Setting & Monitored Parametersa) Tidal Volume; Pre-Set Range For Both Pediatric & Adult Modes To Be Providedb) Inspiratory Pressure (Up To 100Cm Of H2o);C) Respiratory Rate 1 To120 Bpm;D) Apnea Back Up Rate;E) Peep: 0-50 Cmh2of) Inspiratory Flow: 0-120 Lpmg) Max Peak Flow : 280 Lpm Or Betterh) O2 Concentration: 21-100%I) Pressure Support: 1-(100-Peep) Cmh20j) Fio2 Setting Range Between 21% And 100%;K) Pressure Flow & Volume Curves;L) Loop For V-Flow, Flow-P, Flow-Paw And At Least 5 Storage Spaces For Reference Loopsm) I: E Ratio: 150:1 To 1: 299N) Ramp Time: Up To 3 Seco) Inspiratory Time: 0.2 To 15Sp) Pause Time; Exp/Insp Holdq) Pressure Trigger: Up To -10Cmh2o And Flow Trigger Up To 20 Lpm;R) I Flow/T Plateaus) Resistance & Compliance (Cdyn & Cstat)T) Leakageu) P Plateau 14. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw15. Should Have Weaning Parameters;Rsbi,Vt Spont, R Spont ,Vt/Ibw16. Facility To Calculate Lower And Upper Inflection Point (P/V Flex Points)Should Have Recruitment Manoeuvre17. Should Have Automatic Suction Routine & O2 Flush18. Should Have A Dedicated Bronchoscopy Function To Allow & Compensate Ventilation While Performing Bronchoscopy19. Should Have Trend Of 7 Days And Above With Facility To Transfer Through Usb Interface20. Alarms Should Be User Friendly, Audio And Visual With Text Message, System Alarm Should Be For:A) Pressure Changes (High/Low)B) Tidal Volume Changesc) Minute Volume Changesd) High Peepe) High/Low O2 Concentrationf) Power Failure And Low Batteryg) Patient Disconnectionh) Apnea 21 A) The Ventilator Should Have Facility For Co2 Monitoring. Should Have Inbuild Etco2 Interface & Software To Accommodate External Optional Volumetric Etco2 In Future21 B) Should Be Upgradable To :Metabolic Monitoring (Indirect Calorimetry).Price To Be Quoted As Optional.22. The Ventilator Should Not Weigh More Than 12 Kgs 23. Ventilator Should Have In Built Non- Consumable Paramagnetic Oxygen Sensor That Shouldnot Require Change For At Least 5 Years.24. Flow Sensor Should Be Differential Pressure Technology, Or Ultrasonic.Flow Sensor Must Be At Expiratory End. Should Be Maintenance Free, Reusable And Autoclavable.The Flow Sensor, Inspiratory Port, Expiratory Port Should Be Easily Removable Without Using Any Tools & Should Be Autoclavable.25. Should Have Usb /Serial Interface For Communications With Networked Devices26. The Ventilator Should Have On Screen Help Menu For Alarm, Ventilation Mode & Ventilator Settings. The On Screen Help Menu Should Guide User On Solving The Alarms; Providing Information On Ventilation Modes & Settings. 27. Should Support Dual Limb Circuits Of Any Make And Not Ventilator Model Specific Circuits28. The System Should Have Inbuilt Rechargeable Battery With Backup With Minimum 2 Hours29. Power And Gas Requirements: A) Power Input To Be 220-240Vac, 50Hz (100-240 Vac) B) Gas Input (Air And Oxygen) - 29-100 Psi (29-87 Psi)30. The Ventilator Should Be European Ce Certified Or Us Fda Approved, And The Manufacturing Company Should Be Iso Certified.Accessories/Consumables To Be Supplied With Main Unit I. Icu Ventilator With Trolley – 1Nosii. Reusable Adultcircuit - 1 Nos Iii. Hinged Support Arm – 1 Nosiv. Hme Filters—5Nosv. Bacterial Filters-5Nos Vi. Hepa Filetr-1Nos Vii. Test Lung -1Nos Viii. High Pressure Oxygen Inlet Hose – 1Nos , Projector With Screen Brand - Epson / Benq / Lg Cinebeam Technical Specification Ce Marked, Power Supply: 220-240 V Ac, 50/60 Hz, Transparent Lcd Panel Display System, Minimum 5200 Hours Lamp Life, Min. 5800 Lumens Brightness, Contrast Ration 10000: 1, Aspect Ratio 16: 10, Resolution Xga (1024 X 786) With Hdmi And Vga In, Lan & Usb Support, Wireless Support, Light Weight, Remote Control Etc. , Phaco Emulsifier Machine Brand-Alcon Legion / Zeiss Technical Specification 1. Operating Frequency Should Be Approx. 40 Khz 2. Handpiece: Ultralight Ultrasound 4 Crystal Piezoelectric Hand Piece. 3. Us Modes: Continuous, Pulse, Single Burst, Multi Burst, Continuous Burst, Automated Programmable Modulation (Apm) 4. Automated Ultrasound Power On Demand: Ultrasound Management Technology That Automatically (De)Activates Ultrasound Us Delivered Only When Needed Ept Up To 50% Less & Better Followability. 5. Type Of Infusion: Iop Controlled, Synchronized Fluid Exchange System That Directly Measures And Simultaneously Controls Both Infusion And Aspiration Volumes In Real-Time. It Actively Compensates For Incision Leakage. Quattro Controlled Forced Infusion. 6. Display: 24 Inches Touch Screen. 7. Iop Range: 30-120 Mmhg 8. Vacuum Range 0 To 700 Mmhg 9. Aspiration Flow Rate 0 To 120 Cc/Min 10. Aspiration Control Modes: Vacuum Controlled Mode, Flow Control Mode 11. Chamber Stability: Irrespective Of Type Of Cataract, Surgical Conditions, Leakage (0 -12 Ml/Min) It Keep Chamber Stable & Maintain Targeted Iop Throughout Procedure. 12. Iop Recovery Time After Occlusion Break 200-250Ms For Vacuum In Range Of 200 -600Mmhg. 13. U/S Tips: Coaxial Phaco With Incision Size 2.2 Mm 14. Vitrectomy: Pneumatic Cutting Device15. Type Of Vitrectomy Cutter: 23G Anterior Vitrectomy Cutter16. Anterior Vitrectomy Range:Cut Rate 30 To 5000 Cuts Per Minute. 17. Actuation Medium For Vitrectomy: Compressed Air From Internal Source 18. Diathermy: Bipolar With Fixed And Linear Control Via Foot Pedal. 19. Type Of Diathermy Handpiece: Diathermy Forceps And Diathermy Pencil Eraser. 20. Instrument Tray Arm Length: Should Be 800Mm Or More. 21. Dual Linear Footswitch 22. Should Be Usfda And Ce Approved 23. Online Ups Should Be Providedaccessories: Phaco Hand Piece(Coaxial) -2 Coaxial Handpiece Tip I – 2 I/A Bi Manual Hand Piece – 2Phaco Tip (2.2 Mm)- 10 Phaco Sleeve (Silicone)(2.2Mm) – 10 Test Charnber- 10 Tubing And Cassettes (Disposable) – 100 Diathermy Cable With Forceps – 2 Phaco Wrench-2 Vit Cutter- 23 G; Single Use – 6Sterilization Container/ Tray , Autorefractometer & Keratometer (Ark) Brand-Zeiss- Visuref 150 Technical Specification (A)Device Data.(A) Refraction(1) Sphere -25.00D To +22.00D (In Steps Of 0.12D/0.25D)(Ii) Axix 0 To 180*) (B) Keratometer(A) Corneal Curvature 5.00 To 10.20Mm (In Steps Of 0.01Mm)(B)Corneal Redraction-33.000 ?? 67.50D (In Steps Of 0.12D/0.25D)(C) Corneal Astigment-0.00D To-15.00D50d (In Steps Of 0.12D/0.25D)(D)Axis 0 To 180* (In Seps Of 1*) (E) Corneal Diameter (2.00 To 1200Mm (In Steps Of 0.10Mm) , Humphrey Fied Analyzer ( Hfa3) Brand-Zeiss Technical Specification • High Quality Goldman Standard Automated Full Field Perimetry Of International Standard With Bowl Size Radius = 30Cm. • Computer & Monitor Should Be Integrated In The Perimeter (No External Computer). • Stimulus Size I, Ii, Iii, Iv & V.• Background Illumination 31.5Asb.• Maximum Temporal Range 80Deg.Suitable For Central 30, Neurological Tests As Well As Full Field Testing. • Central Field Test Patterns 30-2, 24-2,10-2, Macula.• Peripheral Field Test Pattern 60-4, Nasal Step, Custom Test. • Threshold Test Strategies Full Threshold, Sita Standard, Sita Fast , Full Threshold, Fast Pack, Sita - Swap.• Screening Field Test P-60, Ff-80, Ff-120, Ff-240,Nasal Step For Periphery .• Screening Test Strategies Two Zone, Three Zone And Quantify Defects.• Glaucoma Hemi Field Test, Heijl –Krakau Blind Spot Monitor• Video Eye Monitoring, Gaze Tracking Monitoring System, .. Vertex Monitoring And Head Tracking. • Touch Screen On Crt Monitor, Keyboard & Provision Of External Monitor & Keyboard.•Internal Hard Disk Drive.• Stimulation Duration 200Ms, Wavelength Broad Band Visible Light• Stimulus/Background Colour White On White.• Swap (Blue On Yellow) Perimetery. • Auto Pupil Measurement. • Kinetic Testing & Custom Kinatic Testing. • Motorised Chinrest, Motorised Table, Laser Jet Printer • Glaucoma Progression Analysis ( Gpa ) Software For Monitoring Disease Progression. With Visit Wise Graph &Visual Field Index (Vfi).• Releye Monitor.• Forum Software For Archiving & Offline Analysis Of Patient Data & Gpa Analysis Etc.• Hfa Dicom Gateway. , Laser Dcr Brand-Medfin Technical Specification Applicationsdacryocystorhinostomy Amplifying Medium Diode Ergonomics Tabletop Wavelength-980Nm Average Power -8W Weight -1.2Kg (2.65Lb) , Automatic Tourniquet System With Hose Cuffs Brand - Zimmer Biomet (Model Ats-5000) Number Of Ports Dual Port Number Of Potential Cuffs Dual Cuff Dual Cuff Mounting Options Table Or Pole Mount Table Or Pole Mount Battery Type And Life Lithium Ion 6 Hrs Lithium Ion 6 Hrs User Interface Touchscreen Touchscreen International Alarm Standard 60601-1-8 Compliant Compliant Display 10.1” Color 7.0 Color Minimum/Maximum Pressure 20/600 Mmhg 50/600 Mmhg Pressure Accuracy ±3 Mmhg (20–600 Mmhg) ±4 Mmhg (50-600 Mmhg) Limb Occlusion Pressure (Lop) Allows For Patient Specific Pressure, Which Allows For The Minimum Pressureto Be Used.Yes Noline Occlusion Detection (Acoustic Reflectometry)A Kinked Pneumatic Tube Can Prevent An Inflated Cuff From Deflating, Resulting In Unintentional Tourniquet Pressure. This Alarm Alerts Or Staff That There Is An Occlusion In The Line To The Cuff.Yes , Battery Opreated Heavy Duty Drill & Saw Brand -Manman/Biotech Specifications--- Drill And Reamer Hand Piece Attachments, Oscillating/S Reciprocating Saw Hand Piece Charger And Sterilization Handpiece For Drilling & Reamingtrigger Type Single Modes Available - Reverse & Forward Modedrill Speed 1000 Rpm Approxdrill Torque 4 Nm (35+ In Lbs)Ream Torque 16.5 Nm (145+ In. Lbs)Weight Of Hp With Batteries 1250 Gms Drilling And Reaming Attachments Hudson/Zimmer/Trinkle Reamer Attachment - Yesao Reamer Attachment - Yesao Type Drill Attachment With Quick Coupling - Yesjacobs Chuck With Minimum 6 Mm - Yeskeyless Chuck -Yes Wire Driver Attachment - Yespin Driver Attachment - Yes Dhs Reamer Attachment With Quick Coupling - Yesoscillating/Sagital Saw Hand Pieceergonomic Pistol Grip Design For Maximum Comfort And Control Yes Weight Of Hp With Batteries.- 1350 Gmssaw Speed - 15000+ Cpmcutting Arc - Between 4 To 5 Degreenoise Level - 60-85 Dblspecial Blades Each For Tkr And Thr (Nos) - 10 Battery Specifications Type Of Battery Lithium Ion (Li-Ion) Number Of Batteries 2 , Electric Cautery Machine Brand - Shalya/Enertech/Eclipse/Valley Lab 1) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology 2) Unit Should Have No Of Bipolar Modes Available 3) Unit Should Have Pure Sinusoidal Output Waveform In Hf Power Output In Cut And Bipolar Modes. 4) Type Of Display Should Be Lcd Touch Screen 5) It Should Adjust Power Level Automatically Depending On Tissue Type. 6) It Should Have Two Monopolar Output Channels. 7) Bipolar Current Meter Bipolar Current Meter 8) Unit Should Deliver Two Coagulation Output At A Time With Independent Control Over Each Output For On & Off. 9) Both Channels Should Work By Foot And Hand Control. 10) It Should Complete Self Testing During Power On. 11) Power Efficiency 98 Or More Than 98 12) Availability Of Advance Cutting Modes For Regular Open Surgery 13) It Should Accept Disposable And As Well As Reusable Patient Plate. 14) Unit Should Have Tissue Feedback, Pulsed Interval-Controlled Pulse Cut Function. 15) It Should Accept Dual Area And Single Area Patient Return Electrode. Should Give Green Indication If Dual Area Patient Plate Applied To Patient & Red Indication With Alarm Tone If The Patient Plate Is Not Applied. 16) Bipolar Should Work Without Patient Plate Or Patient Plate Error Condition. 17)Bipolar Should Have Auto Facility To Start & Stop Working Without Footswitch. 18) Unit Should Have Adjustable Delay Activation In Auto-Bipolar. 19)It Should Have Randomized Spray Coagulation For Larger Area Coverage.20)It Should Be Upgradeable For Argon Delivery Module From The Same Oem.21) Unit Should Be Useful For Underwater Procedures. 22) It Should Have Alarm Facility After Completion Of Bipolar Coagulation. 23) Unit Should Have Time Out Function For Automatic Stop The Hf Output If Prolong Unintended Activation. (Optional)24) Unit Should Have Touch Key Pad For Power And Mode Selection.25) System Should Give Error For Faulty Handswitch Of Footswitch In Monopolar & Bipolar.26) Unit Should Give Error For Faulty Keypad. 27) It Should Have No Of Segments Of Display 3. 28) Unit Should Operate From 180 V To 265 V Without Using External Stabilizer. 29) It Should Have Independent Foot Switch For Monopolar Two Paddle. 30) It Should Have Independent Foot Switch For Bipolar Single Paddle. 31) Unit Should Have Facility To Connect Either Monopolar & Bipolar Footswitch.32) Unit Should Have Remote Power Setting Facility From Sterile Field With Conventional Hand Switching Pencil. 33) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. 34)Manufacturer Iso 9001: 2008 & En Iso 13485:2012 Certified Company.35) Warranty Must Be 3 Years Or Higher 36) It Should Be Supplied With Following Reusable And Autoclavable Accessories: -1. Patient Return Electrode …………………….1 No.2. Hand Switching Pencil………………………. 1 No.3. Foot Switching Pencil…………………………1 No.4. Bipolar Forceps …………………………………1 No.5. Cable For Bipolar Forceps……………………1 No.6. Monopolar Footswitch ………………………1 No.7. Bipolar Footswitch ……………………………1 No. 8. Universal Adaptor …………………………….1 No.Set Of Electrode (Angled, Ball And Needle).1No10. Trolley With Lockable Castor Wheel Should Be Supplied1. Unit Should Be Eu Ce (4 Digit Notified Body Certified)2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode 3. Availability Of Test Report From Central Govt/ Nabl/Ilac Accredited Lab Covering All Parameters. And Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification. , Arthroscopy Set (Brand- Smith +Nephew / Karl Storz) Arthroscopy Set 30° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscope. Light Guide Insertion On Definitione Direction View With A J-Lock Fixation For Cannula.Working Length Of Not More Than 160Mm Optimal Centre-To-Edge Resolution For Enhanced Picture Quality Angle Of View: 30 Degree Diameter: 4Mm Arthroscopies Should Be Supplied With Compatible Cannulas High Flow, Double Valve, Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator, Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopy Set 70° (Arthroscopic, Sheath And Obturator) Wide Angle, Direct View 4K High Definition Arthroscopic Light Guide Insertion On Opposite Side Of The Direction Of View With A J-Lock Fixation For Cannula. Fully Rotatable With Fenestrated Tip & Conical And Blunt Tip Obturator. Sheath- 5.95 To 6.0Mm, High Flow Diagnostic Cannula, Double Valve, Fully Rotatable Cannula With Fenestrated Tip. Trocar-4.5Mm Conical Obturator To Fit With Cannula. Arthroscopic Power Shaver System: Input Voltage Of 100 To 240V, 50/60 Hz Power Consumption Not More Than 350Va. Two Separate Receptacles For Motor Drive And Powered Instrumentation. Shaver Should Have 2 Modes Of Oscillation For Aggressive Cutting Shaver Should Have Button For Flush Lavage Of Joints On Footswitch. Autoclavable Ultra-Light Hand Piece With Suction Facility, With 3 Hand Control Buttons And Replaceable Cable Long 10Ft (3 M). Maximum Torque Should Not Be Less Than 32Oz.In And Weight Should Not Be More Than 212 Gms Pedal Style Footswitch With 3 Operating Modes I.E. Forward, Reverse And Oscillation. On-Line Lcd Display For Speed And Direction Referral. Should Communicate With The Fluid Management System Once Connected With The Cable. Camera Control Unit: System Must Have Inbuilt 4K Uhd Camera Console, Led Light Source & Wifi Enabled Image Management System With Recording Via Usb Port Along With Recording In App Through In Built Wifi. Camera Resolution Must Be 3840*2160 (Native) 4K Camera Head: Camera Head Should Have 4K, 3 Chip Mos Video Sensor Technologymust Have Transport Shock And Vibration Compliance With Ista 3Avideo Field Rate 60 Hz Must Have C-Mount Autoclavable Coupler With 19.5 Mm Coupler Length Opt For 4Mm Scopes Must Have Digital Zoom Video Data Transmission High-Speed, Low-Voltage Differential Serial (Lvds), Digital Transmission Via 12-Foot Camera Cablevideo Output Format Full Uhd 2160P, 100% Compatible With Smpte St-425-5 When Used With The Ccu Altitude: 3000 Meters Maximum 4K Monitor: Monitor Should Have Resolution 4096 * 2160 Pixels Monitor Should Support Picture Size (Diagonal) 789.06 Mm (31 1/8 Inches) 1387.8 Mm (54 3/4 Inches) Monitor Should Support Effective Picture Size 698 * 368.1 Mm (27 1/2 * 14 1/2 Inches)Monitor Should Support Pixel Pitch 0.1704 X 0.1704 Mm Monitor Should Have Aspect Ratio Of 17:09Monitor Should Have Pixel Efficiency Of 0.9999 Size Is -125Mb 1300 Seconds Video / Gigabyte Storage 10000 Images/Gigabyte Storage Airprintt Is Required. , Fess Instruments Set Nus Surgery Fess & Dcr Surgery Instruments Brand -Kalelkar / Besco Blakesley Forceps 0 Blakesley Forceps 45Blakesley Forceps 90° Thrucut Forceps 0Thrucut Forceps 45° Thrucut Forceps 90 Maxillary Sinus Forceps 30, 90, 120Hewiser Forceps Tubular Rotatable Kerrison Punch Straight Kerrison Punch Curved Backbiting Forcep Tubular Rotatable Stammberger Ostrum Punch (Mushroom Forceps)Giraffe Forceps Upturned 55, 70, 90, 110 With Vertical Or Horizontal Opening Fronntal Sinus Bougie Set Of 4Sickle Knife Sharp/Blunt Ball Probe Double Ended Right Angledball Probe With J Hook Double Endedantrum Curette Oval Or Round Cup Suction Canulla 45 Or 90° , Micro Ear Surgery Instrument Set (Ear Surgery Instruments) (Stapedectomy Instruments) Brand -Kalelkar / Besco Technical Specification Sickle Knife , Circular Knife Flag Knife , Sickle And Flag Knife Double Ended , Sickle And Circular Knife Double Ended Circular And Flag Knife Double Ended , House Curette Double Ended, Elevator Pick Straight/Curved/Right Angled , Fisch Perforator 0.3 Mm To 0.8 Mm. Hand Burr , Piston Depth Guage , Stapedectomy Instruments , Piston Cutting Jig Piston Autoclaving Box , Teflon Pistonspistion Crimper Micro Ear Scissor Belluchi Operative Ear Speculam Set Of 4 Black Slotted Or Plain Endural Retractor 2X2endural Retractor Left/Right Plester Micro Suction Canulla 116 To 24Gmicro Suction Canulla Adaptor Silicone Suction Tubecartilage Slicer , Tonsillectomy Instruments Set Brand -Kalelkar / Besco Technical Specification Davis Boyles Mouthgag With 5 Blades Davis Boyles Mouthgag With 5 Slotteddraffin Bipod Stand With Plate Tonsil Holding Forceps Tonsil Dissector Cum Pillar Retractortonsil Dissection Forceps Tonsil Artery Forceps Straighttonsil Artery Forceps Curvedtonsil Artery Forecps Negustonsil Scissor Tonsil Snare Tonsil Snare Wire +Quincy Foreps +Adenoid Curette With Cage + Adenoid Currette Without Cage + Younker Suction Canulla +B.P.Handle No 7 + Negus Knot Tier +Thrroat Instruments Tracheatomy Surgery Instruments + Tracheatomy Tube Chevalier Jackson/Fuller + Mosquito Artery Forceps + B.P.Handle No 3 + B.P. Blade No 11 + Fine Scissor 4 +Tracheal Dilating Forceps + Kilner Catpaw Retractor +Skin Hook + Single Hook Retractor +Double Hook Retractor , Nasal Surgery Instruments Set (Septoplasty Instruments) Brand -Kalelkar / Besco Technical Specificationkillians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Specularm Set Of 4 B.P. Handle No 3+Freersdouble Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator Symes Double +Suction Elevator + Lucs Forceps Round Or Heart Shape + Jensen Middleton Septum Cutting Forceps + Jensen Middleton Septum Punch Forceps + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or. Plain + Hammer (Mallet) + Submucosal Diathermy+ Needle/Ball Probe + Nasal Packing Forceps + Spring Scissor + Catspaw Retractor + Tongue Depressor + Rhinoplasty Surgery Instruments + Raps + Cricoid Hook + Jenkins Chisel + Alar Retractor + Aufritch Nasal Retractor + Ash Septum Forceps + Walsham Septum Forceps + Gillies Osteotome + Nasal Packing Forceps + Silver Nasal Chisel With Guard Left/Right + Skin Hook + Cottle Retractor + S.M.R Instruments + Killians Nasal Speculam 2 To 3.5 + St. Clair Thomson Nasal Speculam Set Of 4 + Freers Double Ended Mucopericondrial Elevator + Symes Double Ended Mucopericondrial Elevator + Howarth Double Ended Mucopericondrial Elevator + Suction Elevator + Turbinectomy Scissor + Ballenger Swivel Knife Bayonet Shape + Tilleys Nasal Gouge Bayonet Shape With V Cut Or Plain + Hammer (Mallet) , Micro Laryngeal Surgery Instruments Set Brand -Kalelkar / Besco Laryngoscope Mls Black Finish Adult/Child/Paediatric With Fiber Optic Carrier Chest Supportlaryngoscope Distending Operating Type Laryngoscope For Filling With Endoscopemls Forceps Cup Type Straight/Left/Right/Upward/Downward Mls Forceps Serrated Type Straight/Left/Right/Upward/Downwardmls Scissor Straight/Left/Right/Upward/Downward Mls Vocal Cord Spreader Mls Mini Larygeal Forceps Triangular End Mld Needle Holdermls Ssickle Knife Mls Circular Knifemls Flag Knifemls Probe 45°, 90°Mls Curettemls Handle For Use With Straight Instumentssuction Tube With Thumb Control Insulated Probe For Coagulationbronchoscope/Esophagoscope & Instrumentsbronchoscope Negue Type Any Size With Fiber Optic Carrier Esophagoscope Any Size With Fiber Carrierhypopharyngoscope (Esophageal Speculam) With Fiber Optic Carrier Forceps Alligator Grasping Single Actionforceps Peanut Soft Tissue Single Actionforceps Cub Biopsy Type Single Action Forceps Patterson Type Single Actionforceps Universal Biopsy & Grasping Single Actionforceps Alligator Grasping Double Actionforceps Peanut Soft Tissue Double Actionforceps Cup Biopsy Type Double Actionforceps Patterson Type Double Actionforceps Universal Biopsy &Ngrasping Double Action Suction Tube Rigid With Thumb Conntrol , Mastoid Surgery Instruments Set Brand -Kalelkar / Besco B.P. Handle No 4 Kilner Catspaw Retractormollison Mastoid Retractor 3X3 Mollison Mastoid Retractor 4X4mahadevaiah Modified Mastoid Retractor Left/Right Jensen Retractorjolls Retractor Periosteal Elevatoroperative Ear Speculam Set Of 4 Black Slotted Or Plain Micro Suction Canulla 11G To 24Gmicro Suction Canulla Adaptor Mastoid Suctioncanulla Set Of 4 With Thumb Grip Sickle Knifecircular Knifeflag Knife House Curette Double Ended Elevator Adsons Toothed Forceps Adsons Non Toothed Forceps Needle Holder 6 Fine Scissor 4Micro Ear Crocodile Serrated Forceps Micro Ear Crocodile Cup Forceps Micro Ear Crocodile Scissors Malleus Nipper Ball Probe 45 Degree/90 Deegre Vien Graft Pressossicle Holding Forceps , Fiberoptic Flexible Video Laryngoscopy System Brand -(Penlon / Karl Storz) Specification 1) It Should Be Very Portable And Light Weight Device With Minimum Display Size Should Be 4 Inch With High Resolution Anti Reflective Display. 2) Should Have 180 Degree Horizontal Screen Rotation With Vertical Movement For Betterclinical Assistance. 3) It Should Be A Lithium Ion Rechargeable Battery-Operated Device With Low Battery Indicator. 4) Minimum Operation Item Should Be 130 Mins. 5) It Should Have Led Light Source At The Tip Of The Blade With Minimum 2 Megapixel Cmos Camera For Better View. 6) It Should Have Channelled And Without Channelled Blade Option. 7) Should Have 4Gb Inbuilt Memory For Continuous Recording & Image Capturing. 8) Blades Sizes Should Be Size 1,2, 3, 4,5 . 9) Blade Should Be Affordable, Sterile Which Connect Laryngoscope Handle With Lock. 10) Battery Life Cycle Should Be Minimum 300 Times. 11) It Should Have Iso & Conformity To Ce. , Fiber-Optic Video Bronchoscope(Brand - Karl Storz /Olympus ) Specification Fiber-Optic Video Bronchoscope Required With Video Illumination To Visualize And Document The Operational Area On Screen. It Should Consist Of Following Features: Monitorscreen 8 To 12 Inch In Size For Display With Touch Screen To Control Features With Hdmi Output For Connecting To A Big Screen Which Can Display Picture Simultaneously On Both Screens.Monitor Should Have Two Ports To Connect Two Video Endoscopes At One Time And Pictures Can Be Swapped Using Touch Screen. Monitor Should Be Chargeable, To Be Supplied With Charger And Should Have Facility To Be Used While Charging. Monitor Resolution Should Be Minimum 1920 X 1200 Pixels In 16:9 Format.Integrated Recording Of Video & Still Images Should Be Possible On Data Card Or Usb Drive With Jpeg And Mpeg Format Which Can Be Easily Transferred To The Computer/Laptop. Documented Videos & Still Images Should Be Easily Recalled On The Monitor. Monitor Should Have A Facility To Connect Flexible Scope Directly Without Any Special Coupler Or Accessory. Monitor Should Have Picture-In-Picture & Side-By-Side Mode To View Images From Flexible Video Scopes. Monitor Should Be Splash Proof According To Ip 54 And Should Be Shock Resistant.Monitor Should Have Lithium-Ion Rechargeable Batteries And Run For At Least 100 Mins. When Fully Charged. Soft Bag From Same Manufacturer Should Be Supplied To Place The Monitor And System Can Also Be Operated Without Taking Monitor Out From The Bag. Same Monitor Should Be Compatible With All The Below Mentioned Scopes Of Same Manufacturing Principal Company .Reusable Fiber Optic Video Bronchoscope.Single Use Flexible Intubation Video Endoscope A Fiber Optic Bronchoscope Is A Medical Device Used To Visualize The Airways During Bronchoscopy, A Procedure Where A Thin, Lighted Tube Is Inserted Into The Lungs To Examine Them. The Specifications Of A Fiber Optic Bronchoscope Typically Include Its Outer Diameter, Working Length, Field Of View, Angulation Capabilities, And The Diameter Of Its Working Channel. Key Specifications:Diameter: Bronchoscopes Come In Various Sizes, With Outer Diameters Ranging From 2.5 To 10 Mm. Smaller Diameters (E.G., 4.9 Mm) Are Suitable For Smaller Patients, While Larger Diameters May Offer Better Image Quality And Suction Capabilities. King Length: The Working Length, Which Is The Distance From The Distal End Of The Bronchoscope To The Insertion Point, Typically Ranges From 30 Cm To 60 Cm. View: This Refers To The Angle Of Vision That The Bronchoscope Offers. A Wider Field Of View (E.G., 110-120 Degrees) Allows For A Broader View Of The Airways. Angulation: The Ability To Bend The Tip Of The Bronchoscope Allows For Maneuvering Into Various Airways. Up And Down Angulation Capabilities Are Typically Around 180 Degrees And 130 Degrees Respectively King Channel Diameter: The Working Channel Is The Passage Through Which Instruments Like Forceps For Biopsies Or Suction Devices Can Be Passed. It Is Typically 1.2-2.3 Mm In Diameter Other Notable Specifications: 26/25 All Above Equipment Should Be From Same Manufacturers And Usfda & Ce Approved , Anaesthesia Workstation Complete With Anaesthesia Gas Delivery System, Vaporiser, Circle Absorber System With Built In Anaesthesia Ventilator & Withmultipara Monitor Brand - -Drager/Penlon/Bpl General • Should Have Provision For Delivery Of Oxygen, Nitrous Oxide And Medical Air • The Machine Should Be Capable Of Delivering Low Flow Anaesthesia. • The Anaesthesia Machine With Circle Absorber, Ventilator And Vaporiser Should Be From Same Manufactureranaesthesia Machine Should Be Ce Notified Body Approved. • Anaesthesia Machine Should Be Cdsco Approved. Vaporizer Should Be Us Fda Approved.Should Have Independent Attachments For Connecting Central Gas Supply And Pin Indexed Cylindershould Have Non-Interchangeable Pipeline Hose Inlet Connection To Pipelines For Medical Oxygen, Nitrous Oxide, And Medical Air Should Have Large Size Pressure Gauges, For Easy Visibility, Colour Coded, Two Each For Oxygen And Nitrous Oxide; One For Airanaesthesia Machine Frame Shall Be Manufactured In Strong But Lightweight Material.The Machine Shall Have A Maximum Of Four Castors/Wheels For Manoeuvrability With Front Two Castors Having Brakesshould Have Minimum Two Non-Lockable And Spacious Drawers For Storing Accessoriesthe Frame Shall Have Gcx Compatible Channels Incorporated For Mounting Other Accessories. • The Option For An Integrated Independent Oxygen Flow Meter For Oxygen Delivery Is Mandatory. Frame Shall Accommodate Up To Two Backup Cylinders One Each For Oxygen And Nitrous Oxideon Activation Of The System On/Off Switch Gas Flow And Vaporization Shall Immediately Be Availableshould Have Selector Switch For Selecting Open And Close Circuit Operation • The Common Gas Outlet Shall Be Mounted At The Front Of The Machine (Not Rear Or Side) To Be Easily Accessible In The Event Of An Emergency And For Use Of Alternate Breathing Circuits • The Option For Illumination Of The Writing Table/Work Surface Is Mandatory • The Frame Should Have Integrated Power Outlets To Supply A Minimum Of Three External Devices • Should Have Top Shelf, Manoeuvring Handle And Footrest • Machine Should Have Table Topwork Space To Keep Drugs. • The Unit Should Have A Battery Back-Up Facility For The Ventilator In The Event Of Power Loss. Minimum 90 Minutes Battery Backup Required. • Input Power :100 – 240 Vac Gas Flow • Antistatic And Cascaded Dual Flow Tubes Should Be Available For All Gases (O2, N2o& Air) To Allow Suitable Resolution And Accurate Control At Low Total Fresh Gas Flows. • The Flow Range Shall Be 150Ml-10 Lpm • Should Have N2o Cut Off Facility If O2 Supply Fails. • Should Have Oxygen Failure Alarm Both Visual And Audible. • Should Have Oxygen Flush Facility Bypassing Vaporiser. O2 Flush Switch Should Be Conveniently Placed For Easy Accessibility. O2 Flush Switch Should Be Non-Lockable. • The Unit Shall Have A Mechanical Anti-Hypoxic Device (Ahd) System To Control The Ratio Of Oxygen And Nitrous Oxide. A Completely Mechanical Ahd System, That Requires No Electricity, Is Mandatory • The Mechanical Ahd System Must Limit Minimum Oxygen Levels To Approximately 25% • Should Have Minimum Mandatory Oxygen Flow Of 100 Ml When Switched On • It Shall Be Possible To Deliver Air With Only Basal Flow Oxygen Independent Of The Abovementioned Hypoxic Control. • Gas Flow Shall Be Controlled Mechanically Only • Visual Display Of Individual Gas Flows Is Mandatory, This Shall Be By Physical Means Such As Glass Flowmeters Independent Ofelectrical Power • Flow Meters Should Have The Option Of Backlight Illumination • In The Event Of Complete Power Loss And Battery Failure It Shall Still Be Possible To Set The Fresh Gas Flow Accurately For Each Gas, Manually Ventilate (With Bag) And Continue To Keep The Patient Anaesthetized. • Anaesthesia Machine, Vaporizer And Ventilator Should Be From Same Oem. • Provide Isoflurane And Sevoflurane Vaporizer With Themachine. Vaporizers • The Unit Should Accommodate At Least Two Vaporizers For Anaesthetic Agent Delivery. • The Manifold Should Only Accept Vaporizers With Approved Back Bar Connections And Prevent Usage Of More Than One Vaporizer Simultaneously. Preferably Selectatec Compatible Back Bar. • Vaporizers Supplied With The Unit Shall Be Routine Maintenance Free For The Life Of The Product • Vaporizers Supplied With The Unit Shall Be Manufactured From Lightweight Materials To Aid In Fitting & Removal • Should Have An Operating Flow Range Of0.2 – 15 L/Min And Nominal Capacity 250 Ml Ventilator • Ventilator Shall Cater For A Diverse Range Of Patient Groups From Neonates To Adult Patients With Restrictive Airways • Ventilator Should Be Pneumatically Driven And Controlled Electronically • Ventilator Shall Have A Large 8.4” Colourtft Display, For Exclusive Use Of Ventilator Control And Monitoring. • Control Ofthe Ventilator User Interface Shall Be By Touch Screen And Rotary Dialventilator Shall Have The Following Ventilation Abilities, Volume Control (Vcv), Pressure Control Ventilation (Pcv), Simv-V And Simv-P ,Spont/Pressure Support Ventilation (Psv),Manuaassisted Modes Of Breathing Shall Be Flow Triggered. Ventilator Shall Compensate For Fresh Gas Flow And Compliance Of The Entire Circuit. Should Have User Adjustable Alarms For Major Parameters Such As Tidal Volume, Minute Volume,Fio2,Airway Pressure, Frequency Apnea Alarms Must Be User Adjustableto Allow For All Operating Conditions And Phases During Anaesthesia Ventilator Should Have The Ability To Display Patient Spirometry Loop Ventilator Should Also Display Waveforms For Flow, Volume And Airway Pressure Stem Absorber & Not Remoted Via Tubes Or Channelsvolume Measurement Sensors Should Not Be Disposable Typeventilator Parameterstidal Volume- 10Ml-1600 Mlfrequency- 4-100 Bpm I:E Ratio- 4:1 To 1:10 Inspiratory Pause - 0-60% Of Ti Peep - Off, 3-30 Cmh2o Pressure Limit - 5-70 Cmh2o Minute Volume-0.5 To 60 Lpm Breathing System • The Breathing System Designed So That It Can Be Removed & Replaced As A Complete Unit Without The Use Of Tools • All Parts Of The Breathing System That Are In Contact With Patient Gas Shall Be Latex Free And Autoclavable Except For Non Autoclavableremovable Part Like O2 Sensor And Pressure Manometer. • Bag/Vent Switch Shall Be Integrated On The Absorber And Should Activate Ventilator In Vent Mode And Vice Versa (One Step Operation). • Breathing System Should Have Heater System To Avoid Water Condensation. • Should Have Quick Release Canister For Sodalime , Capacity Minimum 1.5 Litre • The Breathing System Absorber Canisters Shall Have A Bypass System To Allow For Canister Change Mid-Case Without Loss Of Ventilation Pressure. The Requirement For An Automatic Bypass Without Extra Input From The User Is Mandatory • The Ventilator Bellows Shall Be Clearly Visible And Be Of Upright Design.The Bellows Should Ascend On Expiration To Provide A Quick Visual Indicator For Assisted Breathing, Spontaneous Breathing And System Leaks. • Same Bellows Shall Be Used For Adult And Pediatric Application • Should Have Provision For Fio2 Monitoring Cell And Fio2 Value Should Be Monitored On The Main Screen. • A Bag Arm With Positional Adjustment Shalmulti Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Massimo),Nibp (Suntech) Temperature,Dual Ibp, Agm ( Massimo) Mainstream. 3. Should Have 12-Inch Color Lcd Display. 4. Should Have Dual Modes Of Operation: Rotary Knob. 5. Should Display 7 Waveforms Or More 6. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 7. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 8. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 9. Spo2: ? Should Have Massimo Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 10. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 11. Should Have 2 Channels For Temperature Monitoring 12. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. O 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 13. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 14. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. 19.Monitor Should Be Able To Directly Connect With Hospital Information System (His 20.Should Have Standby And Night Mode 21.Should Have Li-Ion Battery 22.Battery Should Have 3.5 Hrs Of Operation 23.Monitor Should Be Ce Certified 24.Manufacturer Should Be Iso Certified 13485:2016 , Bi-Phasic Defibrillator Brand - Bpl/Maestros Technical Specifications For Bi-Phasic Defibrillator • The Machine Should Have Facility For Ecg Monitoring, Bi-Phasic Defibrillation,With Facility To Print Ecg Through In-Built Thermal Printer,• Should Be Extremely Light-Weight (Less Than 10 Kgs) • Should Have Monitoring Facility Through Color Tft Display With Screen Size At Least 7” Or Better. • Should Have Both Synchronous And Asynchronous Mode. • The Defibrillator Should Be Biphasic Technology Based Having Energy Selection Of 2-300 Joules• It Must Be Capable Of Monitoring Ecg Through Ecg Cables, Multi-Function Electrodes And External Paddles. • The Machine Should Be Able To Defibrillate Adult, Paediatric Patients. • The Machine Should Have Ecg Wave Form Display On Bright Screen Along With Other Vital Numeric Information. • Should Be Able To Monitor Ecg• Should Have Facility For Auto Testing When Switched On And During Operations. • The Machine Should Be Compact, Portable With Built In Rechargeable Battery. • Should Have External Pacemaker With Fixed Or Demand Mode. • Should Be Able To Deliver A Maximum Of 300J In Aed Mode • Should Have A Minimum 2 Hours Battery Capacity For Monitoring And 1 Hour Battery Capacity For Giving Minimum Of 100 Shocks.• Energy Selectiononfront Panel Button And External Paddle Buttons • Charge Control On Front Panel Button And External Paddle Buttons • Charge Indicator Charging Tone, End Of Charge Tone, Led In Charge• Shock Control Buttons On The External Paddles • Should Have External Defibrillator Adult And Paediatric Paddles.• Charging Time - Less Than 8 Seconds At 300 J With A New And Fully Charged Battery • The Machine Should Have User Selectable Alarm Settings• The Machine Should Store At Least 24 Events For Viewing Or Recording.Ecg: • Should Be Able To Monitor Ecg Through 5-Lead Patient Cable • Should Be Able To Display Lead I,Ii,Iii, Avr, Avl, Avf And One Of The Chest Leads• Should Be Able To Monitor Heart Rate From 15-300 Bpmgeneral Specifications• The Machine Should Work On Mains As Well As Rechargeable Battery. • The Device Should Be Manufactured From An Iso Certified Organization• Machine Should Be Supplied With Standard Accessories• System Should Be Easy To Operate With Facility To Give Print Command, Charge And Energy Selection On Both External Paddles And On The Main Unit.• Should Have Upgradable Facility For Masimo Etco2.• Should Have Upgradable Facility For Spo2.• Should Have Upgradable Facility For Nibp.• Should Have Upgradable Facility For Pacer Also. , Multi Para Monitor With P, Nibp, Ecg Facility (Brand - Bpl/Maestros/Drager)) Technical Specifications For Multipara Monitor 1. Multi Parameter Patient Monitor, Which Is Suitable For Use In Operation Theatres, Icu & Wards. 2. Standard Configuration Of Ecg, Respiration, Spo2,( Oxyset+), Nibp (Suntech) Temperature. 3. Optional Parameter Etco2, Dual Ibp, Agm 4. Should Have 12-Inch Color Lcd Display. 5. Should Have Dual Modes Of Operation: Rotary Knob. 6. Should Display 7 Waveforms Or More 7. Waveform Colour Can Be Changed From Screen Setup Of The Corresponding Layout Screen. 8. Ecg: ? Should Be Able To Monitor Ecg Through 5-Lead Patient Cable ? Should Have Manual St Analysis Window ? Should Detect 20 Arrhythmias And Generate Alarms. ? The Priority Of Arrhythmia Alarms Can Be Configurable ? Should Measure Pvc & Pac ? Should Be Able To Monitor Heart Rate From 10-300 Bpm ? Should Have User Selectable Modes Like Monitor, Surgery And Diagnosis For Operation In Icu, Ot’S Etc ? Should Have Pacemaker Detection Facility 9. Respiration: ? Measurement Range Of 0 To 150 Breaths Per Min ? Should Have Gain Selection: ×0.25, ×1, ×2, ×4 ? Should Have Sweep Speed Selection Of 6.25Mm/S, 12.5Mm/S, 25Mm/S ? Should Have Apnea Detection Facility ? Apnea Monitoring Limit Range: 10S, 15S, 20S, 25S, 30S, 35S, 40S, 45S, 50S, 55S, 60S 10. Spo2: ? Should Have Nellcor Technology ? Should Have Measurement Range Of 0~100 % ? Should Have On Screen Display Of Numeric Value For Spo2, Pr With Signal Strength Bar And Plethysmograph ? Should Be Able To Select Sat Sec To Avoid False Alarm 11. Nibp: ? Must Be Of Suntech Medical Technology For Clinical-Grade Blood Pressure Measurement ? Should Have Auto, Manual, And Stat Modes Of Operation For Nibp. ? Should Have A Measuring Range Of 0-280 Mmhg 12. Should Have 2 Channels For Temperature Monitoring 13. Should Have Data Storage Capabilities: O 72 Hours Of Trend Data Storage. 2000 Sets Of Nibp Measurement Data. O 200 Alarm Events O Physiological Alarms Can Be Reviewed With 16 Sec Of Associated Waveform Along With Other Parameter Values. Even Print Out These Waveforms With Optional Recorder O 7 Leads Of Ecg Waveform Disclosure At Least Of 1-Hour O Should Have Facility To Transfer The Trend Data To Usb 14. The Monitor Should Have Drug Dose Calculator And Oxy-Crg View Screens 15. Snapshot Facility With Usb Transfer. 16.Should Have Alarm Settings For All Parameters. 17.Should Have Color Coded Alarms And Alarms Priority Can Be Configurable. 18. Should Have Cns Connectivity Of Same Make. , Fully Functional Automatic Dental Chair With Inbuilt Suction And Compressor (Brand- Confident / Chamundi) Programmable Dental Chair, Unit Fitted With Floor Mount Light With Led(Faro, Maia) Operating Light Having, On/Off And Intensity Control By Non-Touchsensor Monitor Mounting Arm High And Low Vacum Motorized Crs Suction System Autocalvable 2 Nos Beecool Ii Light Cure Cordless-1 No Modular Trolley System Over The Patient Airotor Points- 2 Nos Supreme Micromotor 35,000Rpm With Digital Display Of Speed Three Way Syringe- 1 Nos Supreme Optic Scaler With Five Scaling Tips With Endo Chuck 1 No Ss Instrument Tray X-Ray Viewer Multi Function Foot Control Comfort Dental Operators Stool Compressor Monobloc Oil-Free Medical Grade Airotor Air Compressor 1.5/2 Hp With Radiator Cooler, Condensor, Silicon Column Filter For Moisture, Dust Filter Microbial Filter Fitted On Ms Tank. , Dental Aerotor(Brand - Nsk) Push Button With Led Light , Dental Micromotor Contrangle(Brand - Nsk) Latch Type , Dental Micromotor Straight With Led Light (Brand - Nsk) , Round, Straight Surgical Bur For Straight Hand Piece Micromotor Carbide Burs(Brand - Nsk/Prima) , Round, Straight, Inverted Cone And Tapered Fissure Burs For Aerotor Diamond Fg (Brand- Dent Ark) , Rotary Files Niti Files Sx, S1 S2 F1 F2 And F3 (Brand- Dent Ark /Nsk) , Ultraound Color Doppler System (Brand -Samsung Hs30/ Ge Logiq / Mindray Mx7 (3D,4D)/Bpl) Technicalspecification 1. The Units Should Be Latest State Of The Art Digital Color Doppler With Broadband Beam Forming For Cardiac, Abdominal,Vascular And Ob/Gynapplication. The Models With Following (Or Higher) Specifications Need To Be Quoted. 2. The Machines Should Be Usa Fda And European Ce Certified And Should Be Latest In Technology And Launched In 2016 Or Later. The Manufacturing Company Should Be Iso Certified. 3. They Should Have At Least 750000 Digital Processing Channels For High –Resolution Imaging. 4. Imaging Modes : 2D, M- Mode, Color Flow Imaging, Pulse Doppler, Power Doppler, Continuous Wave Doppler And Directional Color Flow Mapping, 3D/4D Imaging Modes 5. The Machine Should Be Supplied With Dedicated 3D/4D Package 6. The Machines Should Have Facility For Simultaneous Dual/ Duplex/ Triplex Mode Display 7. Tissue Harmonic Imaging Should Be Available On All The Transducers. 9. Machines Should Be Capable Of Advanced Real Time Compound Imaging. 10. Should Have Frame Rate 1500 Fps Or More 11. Scanning Depth Should Be 40 Cms Or More 12. High Dynamic Range Of 250 Db Or More. 13. The Machines Should Have 256 Grey Shades (8 Bit) Or More. 14. One Touch Image Optimization Should Be Available In 2D Mode With One Button Automatic Adjustment Of Tgc And Receiver Gain And Compression Curve Based On The Range Of Detectable Tissue Signals. 15. There Should Be One Button Automatic Adjustment Of Doppler Prf, Baseline, Dynamic Range And Gain In Doppler Mode. 16. Pulsed Wave Doppler Should Be Available On All Imaging Transducers With Adjustable Sample Volume Size, Simultaneous Or Duplex Mode Of Operation, Simultaneous, 2D, Colour Doppler, Pulsed Doppler, High Prf Capability In All Modes Including Duplex And Triplex And Automatic Adjustment Of Scale And Baseline. The System Should Have Option To Adjust The Color Flow Mode For High Or Low Flows In One Touch. 17. Machines Should Support Broad Band/ Wide Band High Density Probes Spanning With Frequency Range From 1-20 Mhz (+/- 1 Mhz). The System Should Support Latest Technology Single Crystal Probe Or Matrix Array Probes For Better Resolution And Penetration. 18. Automatic Doppler Analysis Should Be Available With Automatic Real Time Calculation Of At Least Sixof Following User Selectable Parameters Peak Systolic Velocity End Diastolic Velocity, Mean Diastolic Velocity, Volume Flow, Time Average Mean Velocity, Time Average Peak Velocity, Resistive Index, Pulsatility Index, Systolic/ Diastolic Ratio, Acceleration/ Deceleration Times. 19. The Machine Should Have Up To 500000 Images Storing Facility And Cine Loop Review Facility With Memory Up To Minimum Of 25,000 Frames 20. The Machines Should Have Facility Of Direct Storage And Retrieval Of B/W And Color Images (Both Frozen And Cine Loop) In The Inbuilt Hard Disk Drive. In Built Hard Disk Storage Should Be Equal To Or More Than 1Tband Solid State Device In Addition With Capacity 120Gb. 21. The Machines Should Support Four Or More Transducers With Universal Ports Allowing Any Transducer To Be Connected To Any Port. 22. Machines Should Have A High Resolution Fully Articulating Non-Interlaced Flicker Free, Anti-Glare Led Display Of 21 Inches Or More With Resolution 1,920X 1,080 Or Better.In Addition, The Machine Should Have 10” Or More Touch Control Panel For Easy Access. 23. The System Should Have Image Enhancement Options Like Speckle Reduction, Spatial Compounding And Filtered Tissue Harmonics. The System Should Have Adaptive Blending Color To Maintain The 2D Resolution While Working In Color Mode. 24. Zoom Facility (Upto 8 Times Or More Magnification) With High Resolution Results And Pan Capacity In Both Real Time And Frozen Images. 25. The System Should Have Cd-Dvd And Usb Archival (Dicom And Pc Format).There Should Be 4 Or More Usb Ports. 26. Machine Should Be Offered With The Following Broadband Probes (I) Cardiac Package Along With Adult Phased Array Transducer With Frequency Ranging 1.0 - 5.0Mhz (+/- 1.0Mhz). (Ii) Convex Transducer Frequency Ranging ( C1-6Ct) Mhz. (Iii) Liner Transducer Frequency Ranging (L3-12T ) Mhz (Iv) Tvs Transducer Frequency Ranging (Ec3-10T) 27. Online 1Kva Upsand Color Inkjet Printer 28. Preference Would Be Given To Products Manufactured In India, Japan, Korea, Europe, Us. , Laproscopic Surgery Set With Hysteroscope And Resectoscope (Brand Ethicon/ Mindray Medical Pvt Ltd/ Karl Storz/ Conmed/Olympus) Unit And Camera Head The System Should Have The Full Hd Resolution-1920 X1080 Internal Medical Grade Recorder For Capturing Full Hd Videos And Full Hd Stills With Storage Capability Internal Of 50 Gb Or External Medical Grade Recorder Should Be Provided From The Same Manufacturer. System Should Have The Facility Of Controlling The Recording Device From The Camera Head. Video Scopes Can Be Connected To The Same. The Camera System Should Be Able To Provide With 1080 P Lines For Hd Resolution Image. Technical Specifications: Image Sensor: 1 Xcmos Agc: Microprocessor Controller Weight: 130Gm Focal Length: 16Mm Control Buttons: 3 (2 Of Them Freely Programmable) Input: Keyboard Input For Character Generator. Power Supply:-100-240 Vac 50/60 Hz Certified To: Iec 601-1, 601-2-18, Csa 22.2 No. 601, Ul 2601 And Ce According To Mdd, Protection Class1/Cf 2 High-Definition Medical Grade Monitor Led Crystal Display. Max. Resolution Of 1920X1080. Screen Diagonal - 27Inches Desk Top With Pedestal. Should Have The Facility Of Pip Mode. Accessories External 24Vdc Power Supply, Mains Cord, Pedestal. Certified To: En 60601-1, Protection Class Ipx 1 Led Light Source With Fiber Optic Cable Color Temperatures 6400K External Light Source Light Outlets - 1 Light Intensity Adjustment: - Continuously Adjustable Manually From Light So Should Be Supplied With Light Cable, Diameter 4.8Mm, Length 250Cm. Certified To :- Iec 601-1 & Ul 544 Ce According To Mdd, Protection Class 1/C Telescopes Forward Oblique 30 Degree Telescope, Diameter 10 Mm, Autoclavable, Length Optic Light Transmission Incorporated. Forward Oblique 30 Degree Telescope, Diameter 5 Mm, Autoclavable, Length 2 Optic Light Transmission Incorporated Co2 Insufflator Technical Specifications: Gas Flow: 0-400 L/Min Cv 625 Laprascopy Set Pressure: 0-30 Mmhg (4000Pa). High Flow Mode (0 To 40 L/Min.) Sensitive Mode Pressure 15 Mm Hg & Flow 15 L/Min For Sensitive Application Electronic Control And Colour Touch Screen, Following Data Are Displayed On Touch Screen: -Insufflation Mode. Set Value Pressure (0-30 Mmhg). Current Patient Pressure. Set Value Gas Flow (0-40 L/Min). Current Gas Flow. Gas Consumption (0-999 1). Reusable Insufflation Tube For Co2 Gas Up To Patient Body. High Flow Mode With Flow Performance Up To 40 L/Min. Easy And Intuitive Use With User Friendly Color Touch Screen 7 Inch For Easy And Precise Setting Of Set Values For Pressure And Flow And Of Insufflation Mode, As Well As For Clear Display Of Corresponding Set Values And Actual Values. Optical And Acoustic Alarm Signals In The Event Of Patient Overpressure Should Have Hose Pipe. Equipment Cart From The Same Manufacture Should Be Quoted With 4 Or More Helves Isolation Transformer Co2 Cylinder Holder Laparoscopic Instruments- Detailed Description • Veress Pneumoperitoneum Needle With Spring Blunt Stylet, Luer-Lock, Length 13 Cm & 15 Cm –2 Nos • Trocar, Size 11 Mm, Color Code: Green, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel, With Washers Pack Of 10 – 4 Nos • Trocar, Size 6 Mm, Consisting Of: Trocar Only, With Pyramidal Tip Cannula Without Valve, With Insufflation Stop-Cock, Length 10.5 Cm Multifunctional Valve, Three Part Dismantel With Washers Pack Of 10 – 4 Nos • Reduction Sleeve, 11/5 Mm – 1 Nos • Reducer 11/5 Mm– 1 Nos • Telescope, Diameter 10 Mm, Length 32 Cm, Autoclavable, Variable Direction Of View From 0°-90, Adjustment Knob For Selecting The Desired Direction Of View, Fiber Optic Light Transmission Incorporated- 1 Nos •Injection Needle, Luer-Lock, Diameter 1. 2 Mm, Size 5 Mm, Length 36 Cm - 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 3 6 Cm, Right Angled, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert, And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Long, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Dissecting- And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Alligator Jaws, Double Action Jaws, Consisting Of: Plastic Handle Without Ratchet, With Larger Contacact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Siz E 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Jaws With Multiple Teeth, Fenestrated, Long, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, 2 X 4 Teeth, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle With Manhes Style With Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Bowel Grasper, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Double Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube, Insulated., Three Parts Dismantle 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Cleaning, Single Action Jaws, Atraumatic, Fenestrated, Curved, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet Metal Outer Sheath, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Three Piece Laparoscopic Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Atraumatic, Fenestrated, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Insert And Outer Tube, Three Part Dismantel. 1 Nos • Three Plece Laparoscopic Dissecting And Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, Heavy, Double Action Jaws, Consisting Of: Plastic Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel – 1 Nos • Three Plece Scissor, Rotating, Dismantling, Insulated, With Connector Pin For Unipolar Coagulation, With Luer-Lock Connector For Deaning, Double Action Jaws, Curved, Length Of Blades 15 Mm, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Insulated, Without Ratchet Metal Outer Sheath, Insulated Scissors Insert For Use With Trocars Size 6 Mm Three Part Dismantel 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) 1 Nos • Three Piece Laparoscopic Hook Scissors, Rotating, Size 5 Mm, Length 36 Cm, Jaws Not Crossing With Connector Pin For Unipolar Coagulati On, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area, Outer Tube, Insert, Three Parts Dismantel 1 Nos • Three Plece Laparoscopic Autoclavable Grasping And Dissecting Forceps, Single Action Jaws, Fenestrated, 360 Degree Rotational Sheath, Size 5 Mm, Length 36 Cm, Long, Ergonomic Metal Handle With Plastic Finger Rings With Larger Contact Area At The Finger Ring To Avoid Pressure Sores, Can Be Dismantled With The Press Of A Button. 1 Nos • Suction And Irrigation Tube, Anti-Reflex Surface With Two-Way Stopcock, For Single Hand Control, Size 5 Mm, Length 36 Cm 1 Nos • Olsen Suction Or Irrigation Tube, With Protection Basket, With Trumpet Valve, Size 10Mm Length 36Cm. 1 Nos • Dissecting-Electrode, L-Shaped, Size 5 Mm, Length 36 Cm, With Connector Pin For Unipolar Coagulation, Consisting Of: Outer Tube, Insulated Plastic Handle Electrode L-Shaped With Trumpet Handle 1 Nos • Coagulating And Dissecting Electrode, L-Shaped, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Coagulating And Dissecting Electrode, Spatula-Sheaped, Blunt With Connector Pin For Unipolar Coagulation, Size 5 Mm, Working Length 36 Cm 1 Nos • Macro Needle Holder, Ergonomic Axial Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Left Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Macro Needle Holder, Ergonomic Pistol Handle With Disengage Able Ratchet, Ratchet Release On The Right Side, Right Curved Jaws, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm 1 Nos • Dismantling Needle Holder, Ergonomic Pistol Grip With Disengage Able Ratchet, Ratchet Release On The Left Side, Jaws Curved Left, With Tungsten Carbide Insert # 5 Mm, Length 33 Cm Consisting Of: Insert, Outer Tube, Handle 1 Nos • Unipolar Hf Cord With 4Mm Banana Plug And Length 300 Cm 1 Nos • Clip Applicator, For Use With Ethicon Titanium-Clips Lt-300 (Medium Large), Dismantling, Rotating, With Ratchet To Lock The Jaw Part Holding The Clip, Size 10 Mm, Length 36 Cm, Consisting Of: Metal Handle, With Ratchet Metal Outer Tube Insert, Three Part Dismantel, 1 Nos • Claw Forceps, Rotating, Size 10 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Metal Handle, With Manhes Style Ratchet Outer Tube, Insulated Forceps Insert, Three Part Dismantel. 1 Nos • Claw Grasping Forceps, Rotating, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 36 Cm, 2 X 3 Teeth, Single Action Jaws, Consisting Of: Plastic Handle, Without Ratchet, With Larger Contact Area Outer Tube 1 Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Especially Suitable For Dissection, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1Nos • Rotatable Bipolar Grasping Forceps, Rotating, Dismantling, With Connector Pin For Bipolar Coagulation, Double Action Jaws, Fine Atraumatic Serration, Fenestrated, Size 5 Mm, Length 36 Cm Consisting Of: Plastic Handle, Without Ratchet, Color Code: Light Blue Outer Sheath Forceps Insert, Three Part Dismantel. – 1 Nos • Bipolar Hf Connecting Cable Length 300 Cm, Compatible With All Standard Cauteries – 1 Nos • Fascial Closure Instrument For Sub Cutaneous Ligature Of Trocar Incisions – 1 Nos • Myoma Fixation Instrument, Screw Shaped, 5 Mm. – 1Nos • Dismantling Fan Retractor, Distendable, Size 5 Mm, Length 36 Cm.- 1 Nos • High Frequency Needle, For Splitting And Coagulation, Insulated, Retractable, With Connector Pin For Unipolar Coagulation, Size 5 Mm, Length 31 Cm. 1 Nos • Single Use Scissor Insert Pack Of 10 (1X10) - 1 Nos • Uterine Manipulator: Uterine Manipulator For Providing Tissue Tension Needed For Anatomical Surgery. The Manipulator Should Have Application In Tlh, Lash, Lavh And Hysterectomies For Malignant Pathologies 1 Nos • Sterilization Tray For 2 Telescopes (Same Manufacturer) • Sterilization Tray For Instruments (Same Manufacturer) Hysteroscopy Set Hysteroscope Sheath For Diagonostic Continuous Irrigation Size 6.1-6.3Mm Outer Sheath And 5.1-5.3 Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. Hysteroscope Sheath For Operative Continuous Irrigation Size 5.9-6.1Mm Outer Sheath With Operating Channel 5Fr, Leur Lock Adaptor And 5.3-5.5Mm Inner Sheath For Use With 4Mm Hysteroscope Telescope. With Stopcock & Leur Lock Adaptor And Inflow And Outflow Channe Semi Rigid Instruments For Use With Operating Hysteroscope Scissors Semi Rigid, Blunt Tips, 5 Fr., Length 36-40Cm, Single Action Jaws Scissors Semi Rigid, Pointed Jaws, 5 Fr., Length 36-40Cm, Single Action Jaws, Semi-Rigid Biopsy- And Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Tenaculam Grasping Forceps Semi Rigid, 5 Fr., Length 36-40Cm, Double Action Jaws Bipolar Vaporization Electrode, Semirigid, 5 Fr., Needle Electrode Angled 90°, Length 42Cm Bipolar High Frequency, Should Fit In Most Of The Standard Electrosurgical Unit Having Bana Plug One Side, Length Should Be Not Less Than 250Cm Telescope 12, Enlarged View, Diameter 4 Mm, Length 30 Cm, Autoclavable, Fiber Optic Light Transmission Incorporated Bipolar Working Element To Be Used With 26 Fr Resectoscope Sheath: Motion By Means Of A Spring. The Thumb Support Is Movable. Return Of The Loop Is Control By The Thumb And In Rest Position The Electrode Should Rest Inside The Operating Sheath, To Be Used With 4Mm Hysteroscopy Telescope. Should Work In Saline Bipolar Cutting Loop 24 Fr Should Work In Saline Cutting Electrode 24Fr, Bipolar, Pointed, Should Work In Saline Coagulating Electrode 24Fr, Bipolar, Ball End Should Work In Saline Continuous Flow Resectoscope Sheath 26 Fr., For Bi-Polar, Including Connection Tubes For And Outflow, 2 Luer-Lock Adaptors, 26Fr, Oblique Beak, Rotating Inner Tube, With Ceramic Insulation, For Use With Working Element. Should Work In Saline Obturator, For Use With The Resectoscope Sheath. Fluid Management System (Irrigation & Suction Unit) Pressure Regulated Suction And Irrigation System For Use In Laparoscopy And Gynaecology Unit Should Have Touch Screen As User Interface. Unit Should Have Feature Of Automatically Fixing Maximum Parameters For Laparoscopy And Hysteroscopy Mode By The Choice Of Tubing Unit Should Have Feature Of Simultaneous Display Of Set Values And Actual Values Enabling User For Continuous Monitoring Of Suction And Irrigation Parameters Unit Should Have Feature Of Use Of Disposable/Reusable Cassette Tubing Set For Laparoscopy/Hysteroscopy Procedures. Unit Should Be Supplied With Glass Suction Bottle 5 Lite Unit Should Have Pressure Settings: Hysteroscopy Mode: 0-200 Mmhg Laparoscopy Mode: 100/300/500 Mmhg Unit Should Have Flow Settings: Hysteroscopy Mode: 200/400/600 Ml/Min Laparoscopy Mode: 0-1300Ml/Min Suction Pressure Regulated: Hysteroscopy Mode: 0.1-(-)0.8Bar (-80Kpa) Laparoscopy Mode: 0.1-(-)0.8Bar(-80Kpa) Power Supply: 100-240Vac, 50/60Hz Certified To: Iec 601-1, Ce Nach Mdd Certified To: Iec 601-1, Ce Acc. To Mdd Note: - All The Above Items Should Be Usfda And European Ce Certified And From Same Manufacturer For Better Compatibility And Maintenance , Integrated Electrosurgical Unit And Vessel Sealer Brand -Ensurge/ Hti Digital / Kls Martin / Enertech/Shalya Specifications For Integrated Electrosurgical Unit And Vessel Sealer 1) Advanced Electro Surgical Unit With Vessel Sealing System Have Mono Polar Cut & Coagulation, Bipolar And Vessel Sealing Technology, All Integrated In Single System 2) Type Of Display Should Be Lcd Touch Screen 3) Display Size Should Be 5” Or More 4) Unit Should Have Microprocessor-Controlled Tissue Feedback Technology. 5) The System Should Have Capability To Convert Electrical Energy To Radio Frequency Energy Thus Providing Radio-Frequency Seal 6) Number Of Tissues Sensed Per Sec Should Be 4000 Or Higher 7) Vessel Fusion System Must Be Able To Seal Artery, Veins Along With Tissue Bundle Up To & Including 7Mm In Diameter & Sealed Vessels Should Be Able To Withstand At Least 3 Times The Systolic Blood Pressure. 8) Low Frequency Leakage Should Be 50 Or Higher (In Ma) 9) High Frequency Leakage (Rf) Must Be Less Than 100Ma In Mono Polar And Vessel Sealing Mode And Less Than 70Ma In Bipolar Mode 10) Should Be Provided With Rs 232 Data Input Port For Software Upgrade Facility 11) System Must Have Recall Facility To Recall The Last Setting Used By User Before Turning Off The Power Directly Or Through User Programs. User Can Use Pen Drive With Their Setting To Recall The Setting Saved By Them. 12) System Should Have Bipolar Resection Including Under Water Cutting. 13) The System Should Be Provided With Twin Monopolar Socket (Only One Socket To Be Activated At A Time) With Independent Power Setting 14) 5 Or More Numbers Of Cutting Modes Available In Monopolar 15) Maximum Power Should Be 400W Or Higher 16) Maximum Power Of Blend Mode For Cutting With Homeostasis Should Be Not Less Than 250W 17) Fulgurate/Forced Mode, Spray Mode, Soft Mode Of Monopolar Coagulation Should Be Available. 18) Unit Should Be Supplied With 4 Or More Nos. Of Monopolar Coagulation Modes 19) Coagulation Mode Power (Monopolar) Should Be 150W Or Higher 20) Coagulation Mode Power (Bipolar) Should Be 120W Or Higher 21) Number Of Bipolar Cutting Modes Should Be Or Greater Than 5 22) Maximum Power For Ligation Not Less Than 100W 23) Maximum Power For Resection Not More Than 300W 24) Equipment Should Have On Screen Review Of Error Codes And Diagnostics. 25) System Should Have Patient Plate Contact Quality Monitoring System Giving Audio-Visual Alarm And Deactivating Output If Contact Between Patient And Patient Plate Is Not Proper To Eliminate The Risk Of Patient Burns. It Should Be Mandatory, Should Have Contact Quality Monitoring With Split Style Patient Return Electrode And Deactivates Output If Contact Between Patient And Patient Return Electrode Is Not Proper To Eliminate The Risk Of Patient Burns, Manufacturing By Same Oem 26) Auto Bipolar Start And Stop Along With User Configurable Auto Start Facility Should Be Available 27) Power Output Of Vessel Sealing System (Vss) Not More Than 150W 28) Vessel Sealing System Should Be Able To Seal Vessels Or Tissue Bundles Faster Than Any Conventional Devices (Preferably Within 2-4 Seconds) 29) Product Should Be Ce Certified (4 Digit Notified Body). 30) It Should Have Iec-60601-1-1, Iec 60601-2-2 Safety And Design Standards Certification & Iso 9001: 2008 & Iso 13485:2003 Certified Company. 31) Warranty Of The Unit Should Be 5 Years 32) It Should Be Supplied With All Following Accessories, Should Be Reusable And Autoclavable: - O Patient Return Electrode --- 1 No. O Cable For Return Electrode --- 1No. O Hand Switching Pencil --- 1 No. O Foot Switching Pencil --- 1 No. O Double Pedal Footswitch With Toggle Function (Common/Individual For Monopolar, Bipolar And Vessel Sealing) - 3 No. O Universal Adaptor --- 1 No. O Bipolar Forceps --- 1 No. O Cable For Bipolar Forceps --- 1 Nos. O Set Of Electrode (Angled, Ball And Needle) ------ 1No. O Reusable Sealing Clamp With Cable--- 1 No. O Curved Jaw Vessel Sealer 5 Mm, 32 To 37 Cm -- 1 No. O Autoclavable Reusable Cutting Instrument – 1 No. Additional Terms & Conditions: 1. Vessel Sealing Laparoscopy Instruments Should Have Both Hand And Foot Activation Mode And Should Be Eu Ce (4 Digit Notified Body Certified) Or Usfda Approved. 2. All Sockets Should Be Of Blinking Light Type When In Use To Identify The Used Mode. 3. R.F. Frequency Should Be In Between 350-500Khz For All Modes. 4. It Should Have Bipolar Rf Scalpel Mode For Dissection & Desiccation. Rf Bipolar Scalpel Instruments Should Have Hand Control Button For Coagulation & Cut. 5. Equipment Should Be Usfda Approved/ Eu Ce (4 Digit Notified Body Certified). It Should Have Iec-60601-1- 1, Iec 60601-2-2 Safety And Des , Ctg Machine Brand - Bpl/Maestros/Bistos Specification Foetal Monitor With Display And Printer Should Have 12.1” High Resolution Colour Tft Display With Tiltable Screen For Better Viewing. Should Display Fhr, Toco, Foetal Movementin Numeric Values . Should Display 2 X Fhr And Toco Graphs In Different Colours. Should Have The Facility For Data Save With Play Back & Print Facility Should Have Facility To Monitor Information Of Last 25 Hours Should Have Special High Sensitive Watertight Probe For Better Durability Should Have The Low Ultrasound Power For The Safety Of The Foetus Should Have Automatic Foetal Movement Detection Should Have Event Marking Facility By Mother And User Thermal Printer With Minimum 152Mm Paper Width Is Essential For Broader Printouts Standard Configuration Should Be Fhr, Toco, And Foetal Movement Should Have Volume Control For Fhr Beep Sound And Alarm. Should Have Alarm Setting For Weight Should Be Less Than 4 Kg For Easy Portability. Should Have Foetal Stimulator Built In To Fhr Probe And Activation Key Should Be There On The Front Panel. Stimulation Should Be Recorded On The Recording Paper And Should Be Displayed On The Screen. Built In Rechargeable Li-On Battery For Backup Should Work With Input 200 To 240Vac 50 Hzsupply Central Monitoring System Software Upgradability Should Be Possible (Optional) Should Be Supplied With The Following Standard Accessories: Power Cord- 01 Fhr Probes – 01 Nos Toco Probe -01 Patient Event Marker Belts – 02 Nos Gel – 1 Bottle Thermal Paper- 02 No , Digital Video Colposcope Brand - Bpl/Maestros/Bistos Specification 1. Should Have Led Cold Lighting System Reproduces An Original View Of Tissue. 2. Led Lights Are Replaceable. 3. Should Have Advanced And Fast Auto-Focusing System To Ensure Clear Image. 4. Should Have Remote Capture Control And User-Friendly Keyboard Layout For One Handed Operation. 5. Should Have Electronic Green Filter That Enhances Vascular Image Display Without Compromise Of Illumination. 6. Should Have Working Distance Of 6.7 - 11.8 (170 - 300 Mm). 7. Should Have Magnification Of 1X - 36X. 8. Should Have Resolution Of 3,80,000 Pixels Or More 9. Should Have Horizontal Resolution Of > 470 Lines. 10. Should Have Field Of View Of 0.4 - 5.9 (10 - 150 Mm). 11. Signal/Noise Ratio Should Be = 50 Db. 12. Should Have Signal Output Of S-Video, Pal/Ntsc. 13. Should Have Acetic Acid And Iodine Reaction Test Timer To Precisely Detect Low/High Grade Cin. 14. Should Have Real-Time Display Of Magnification. 15. Should Have Powerful Colposcopic Findings Gallery For Comparison Analysis. 16. Should Have R-Way Evaluation Program Supports Cervical Disease Diagnosis Guidance For Clinical Users. 17. Should Have Dicom 3.0 Supportive. 18. Should Be Manufactured By An Iso Certified Company , Vessel Sealing Device For Open Surgery Shaft Length-23Cm Curved Tip (Box Of 6)(A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology. Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A} Curve Jaw Vesselsealer B) Should Be Able To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. C) Sealing Should Withstand 3 Times Systolic Pressure. D) Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 23 Cm; Shaft Diameter 5 Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. Technical Specification For , Vessel Sealing Laparoscopic Surgery, Shaft Diameter-5Mm, Length-37 Cm Jaw Type Curved Jaw Double Action With Contoured Tips, Shaft Rotation 350 Degrees, Jaw Surface-Textured Ceramic Stops.Jaw Aperture-13Mm Seal Plate Length- 20.3(Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Blunt Tip Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Sealing Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm D) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness:Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. E) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Instrument For Open Surgery, Instrument Length 20.6Cm-21 Cm, Curved Jaw, Hand And Foot Switching(Box Of 6). Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Exact Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 21 Cm. D) Curved Jaw In 28 Degrees, Seal Length 19.3Mm, Cut Length: 18.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device Laparoscopic Surgery. Shaft Diameter-5 Mm, Maryland Jaw Curved Device Length 37Cm (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Curved Jaw Vessel Sealer Hand Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec B) Sealing Should Withstand 3 Times Systolic Pressure. Scaling Length 20 Mm; Cutting Length 18 Mm, Shaft Length 37 Cm; Shaft Diameter 5 Mm C) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation D) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Vessel Sealing Device For Open Surgery With Shaft Length 18.8 Cm, Jaw Type-Curved Jaw (Box Of 6) Brand - Enertech/Ensurg/Hti Digital/ Kls Martin A) Small Jaw Open Instrument Working Based On Tissue Impedance Sensing Technology, Capable To Seal Any Vessel Of 7 Mm Diameter With Automatic Sealing Time 2-4 Sec. B) Sealing Should Withstand 3 Times Systolic Pressure. C) Instrument Length Should Be 18.8 Cm. D) Curved Jaw In 28 Degrees, Seal Length 16.5Mm, Cut Length: 15.5Mm E) Jaw Surface Should Be Nano Coated For Faster Cooling And Less Stickiness; Jaw Temperature Should Not Exceed 91 Degrees Celsius After Multiple Activation. F) It Should Have Cable With Rf Id And Compatible With Existing Rf Generator. , Ethelene Oxide Sterlization Machine ( Brand - Steri Techno Fab/ Map Industries) 1) Eto Gas Sterilizer Should Be Fully Automatic Type With Software-Controlled Operation System For Low Temperature Sterilization Of Heat And Moisture Sensitive Medical And Surgical Items. 2) The Chamber Should Be Preferably Rectangular With Capacity Of 250 Litters Or 9 Cu. Ft. & Dimension 48”(L) X18”(W)X18”(H). 3) The Operating System Should Be Programming Logical Controller Based And Should Have Touch Screen Human Machine Interface From Where User Should Operate And Observe The Cycle . 4) The Inner Surface Should Be Smoothly Finished To Minimize Gas Deposits. 5) Manufacturer Should Provide The Test Report To Prove Conformity To Specification And Ability Of Eto Unit To Achieve Complete Pathological/Microbiological Elimination. The Test Of Report Has To Be Attached With Technical Bid Document. 6) Surface Heaters Should Mount On The Chamber For Uniform Temperature In Chamber Throughout Cycle. 7) Less Noisy And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 8) The Machine Should Be Provided With Plc Based Automation Along With Lcd Hmi Which Allows The Operator For: (A) Change And Set The Parameters (B) Run The Cycle According To Pre-Selected Cycles. (C) Monitor Various Phases / Individual Parameters During The Process. (D) View On/Off Status Of The Various Components Of The Machine While The Cycle Is In Progress. 9) It Should Have Password Protection For Unauthorized Access & Analogue Input Of Process Pressure/Vacuum. 10) It Should Have Digital/Analogue Input For Temperature & Temperature Should Be Indicated In The Sterilization Area, By The Use Of A Temperature Sensor. 11) One Pressure/Vacuum Sensor For Display Of The Current Pressure/Vacuum, That The Load Should Be Subjected To, At All Times During The Process. 12) The Software Should Provide & Maintains Total Records Required For Process Parameters During The Sterilization Cycle. These Records Are Necessary For Meeting Ce Or En 1422 Norms Of Sterilization. 13) All The Fittings For The Accessories And The Main Vessel Should Be Fabricated From Ss 304 Stainless Steel. All The Valves Used In The Process Lines Should Be Ss 304/Brass/Teflon Construction Ball Valves. (All Standard Makes) 14) Pressure Testing And Vacuum Testing As Per Specified Standards. (1.5 Times The Working Pressure) 15) Automatic Operations As Well As Manual Operations In Case Of Technical Problems Should Be In Plc/Hmi. 16) Machine Should Not Open During Sterilization Process, It Should Be Open Only After Complete Cycle Of Sterilization. 17) It Should Be Plc Based Automation System. Plc Should Be Honeywell Or Siemens. System Should Be 21 Cfr Compliances. 18) Automation Should Be 7’’ Touch Screen Display Of Schneider Or Proface Or Equivalent. 19) The Construction Of Chamber Should Be Of Ss316 Grade Stainless Steel. 20) There Should Be Interlocks With Door Mechanism So Cycle Should Start Only After Closing Of Door. 21) Cartridge Puncture Operation Should Be Automatic Into The Chamber No Need Of Manual Puncturing. 22) In Case Of Cartridge Puncture There Should Be Alarm System. 23) One Complete Cycle Should Be Containing All Phases. Time Based Parameter Should Be Mention In Non-Editable Data Sheet. 24) Temperature, Pressure, Humidity, And Other Parameters Should Be Display In Hmi Screen. 25) It Should Be Noise Proof And Vibration Proof Vacuum Generator Should Be Provided For Vacuum Instead Of Vacuum Pump. 26) It Should Be In Built Aeration Phase To Remove Residual Gas Out From Sterile Item. 27) Pre-Requisite Sequence Phases Should Define To Run Cycle In Auto Mode. 28) Pre-Sterilization Phases Should Define To Create Proper Condition For Sterilization (I.E. Humidity& Temperature). 29) Post-Sterilization Phases Should Define To Remove Residual Gas From The Product. 30) Machine Should Have Manual Override Operating Facility. 31) Accessories Needs To Be Supplied With Machine: - ? Suitable Air Compressor Of 1 Hp Capacity. Air Compressor Should Be Oil Free And Less Noisy As Compared To The Traditional Oil-Based Compressor. ? 1 Nos Wire Mesh Type Basket For Loading & Un-Loading Of Sterilization Materials. ? Manual Sealing Machine Suitable Medical Use Sealing. Machine Should Operate On 240 V/50 Hz Operated And Make In India Product. Eto Gas Cartridge Of 1 0 0 Grams- 1 0 Nos. Eto Cartridge Should Be Of Same Make Of Machine. Bidder Must Have To Attach Msds Sheet Of Eto Gas Cartridge With Bid Document. 32) The Manufacturer Shall Have Below Listed Certification To Prove His Eligibility And Copy Of The Certificates Should Be Enclosed With The Offer. ? Iso 9001:2015 For Quality Management System. ? Ce Certificate For Eto Sterilizer & Eto Cartridge Compliance With The Requirement Of Directive Council Directive On Medical Devices 93/42/Eec As Amended 2007/47/Ec. ? Quality Management System For Medical Devices Iso 13485:2016 For Eto Sterilizer & Eto Cartridge. ? Risk Management To Medical Devices Iso 14971:2007 For Eto Sterilizer & Eto Cartridge. ? Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use - Part 2-040: Requirements For Sterilizers And Washer Disinfectors Used To Treat Medical Materials Iec 610102-040:2020 & Iec 61010-1- 040:2020. ? As Eto Gas Toxic And Carcinogenic Properties Environment Management System Certificate. ? Medical Electrical Equipment Iec– Part 1-2: Requirement For The Basic Safety And Essential Performance Of Multifunction Patient Monitoring Equipment. ? Iso 45001:2018 For Occupational Health And Safety Management System. ? Iso 20857:2010 And Rohs Directive (2011/65/Eu) On The Restriction Of Use Of Certain Hazardous Substances In Electrical And Electronic Equipment. ? Fda & Who-Gmp Certificates To Prove Standard Of Manufacturing Practice , Ot Light ( Brand - Shalya/Mattrix/Surgident) Description Of Function Led Surgical Lights Illuminate The Surgical Site For Optical Visualization Of Small Low Contrast Objects At Verifying Depths In Incisions And Body Cavities. 1. General Requirements 1.1. The Light Shall Adopt Led Technology To Create A Homogenous Light Patch Without Emitting Any Infrared Rays. 1.2. The Light System Shall Be Dual Light Heads, One Major And One Satellite. 1.3. Light Should Have Electronic Focusing From Control Panels Without Any Motorized Or Mechanical Movement Of Light Panels. 1.4. All Dome Should Have 2 Colour Led Lamps, White (Cool White) & Amber (Warm White) To Achieve High Cri And Get The Required Shade Of Light As Per Different Surgical Requirements. 1.5. High Power Leds Of 5Watts & Above Should Be Used To Provide High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area <2 Deg. 1.6. Lights Should Have Higher Watts Leds To Achieve High Lumen To Watt Ratio Which Leads To Lesser Energy Consumption And Low Heat At Surgical Area. 1.7. Pulse Width Modulation-Controlled Led Driving To Ensure Less Heating Of Led Which Increases Life Of Leds And No Change In Light Colour Output And Light Colour Temperature Throughout Life. 1.8. The Major System Shall With Automatic Illumination Control System With Sensors On The Light Head. When Some Part Of Led Is Masked By Surgeon’S Head Or Shoulders, The Remaining Led’S Will Become Brighter Automatically To Compensate For The Losing Illumination. 1.9. Light Intensity Shall Be Adjustable Between 30% -100% And Should Have Low Intensity Light For Endoscopy Mode. Light Intensity, Light Field Diameter And Color Temperature Should Be Controlled From Electronic Touch Control Panel Mounted On Light Arm And Wireless Wall Mount Electronic Touch Control Panel. It Should Also Have Provision To Control The Intensity, Electronic Focus, Depth From Sterile Field Though Capacitive Touch Control Handles. 1.10. The Light Head Shall Be Of Petalled / Winged Shape To Avoid Obstruction To Laminar Flow On Surgical Field. 1.11. The Color Temperature Shall Be Synchronized & Controlled By Either Light Head Control Panel. 1.12. The Light Shall Be Mountable To Ceiling From Single Center With 360-Degree Rotation Of All Arms. Spring Arms Shall Be Rotatable At Least 360 Degrees Around Its Own Axis. Each Dome Head Should Be Rotatable With 360 Degree At Connecting Joint With Spring Arm And At Least 300 Degrees Around Its Own Axis. This Feature Should Be Applicable With A Camera Mounted Dome Also. 1.13. The Maximum Movement Angle Of The Spring Arm Shall Be At Least Up 45°And Down 50 1.14. The Thickness Of The Light Head Shall Be No More Than 70 Mm. 1.15. Each Led Shall Be Replaceable Individually To Save Cost In Case Of Failure, Instead Of Replacing The Module With Several Leds. 1.16. The Surgical Light Should Be Complete With All Components For Celling Mount And Electrical Feed-In, Including Finalized Installation. 1.17. Detachable & Auto Cleavable Handle (3 Nos.) For Each Light Should Be Provided. 2. Technical Requirements Of Both Domes: 2.1 It Should Have 2 Colour Led Lamps, White ( Cool White) & Amber( Warm White) 2.2 The Central Illuminance Should Be 160,000 Lux 2.3 Light Field Diameter Should Be Adjustable From 150Mm To 300Mm 2.4 D10: 300Mm & D50 :160Mm 2.5 Color Temperature (K), Adjustable From 3500-5000K 2.6 Color Rendering Index Ra Should Be 95 Or More And R9 Should Be 93 Or More 2.7 Depth Of Illumination (L1+L2) As Per Iec 60601-2-41 (Ver 2003) Should Be 650Mm And As Per Iec 60601-2-41 (Ver 2008) Should Be 1200Mm. 2.8 Dimming Range Should Be Between 25-100% 2.9 Endoscopy Mode Illumination Should Be Less Than 5% Of 160,000 Lux 2.10 Number Of Led Bulbs The Light Head Should Not Be More Than 70 2.11 Led Service Life Should Be Minimum 60000Hrs 2.12 Light Head Dimension Should Be 700Mm (=/- 20Mm) 2.13 Max. Power Consumption Of All Light Sources Should Be Less Than 100W At Maximum Setting. 2.14 Power Supply Should Be 100-240V Ac, 50-60Hz 2.15 One Dome Should Be Ready For The Wireless Camera Attachment. 3.Standards • Iso 9001:2008 • Iso 13485:2003, • European Ce With 4 Digit Notified Body / Eu Ce With Eu Free Sale Certificate /Us Fda Registered . • Should Compliance With: Iec 60601-1, Iec 60601-2, Iec 60601-2-41, Certificate From Any Nabl Accredited Lab / Any Lab From Country Of Origin For Imported Brands , Suction Machine (Electrical) (Brand -Supreme / Goley) Type: Electrical Pump Type: Oil Immersed Rotary Vane Capacity: High Vacuum Voltage: 220 Vac, 50 Hz, 1 Ph Number Of Wheels: 04 (Antistatic) Air Flow: 35 Ltrs/Min Current: 1.8A Noise (Decibel): 30~35 Dba Power Consumption: 370W Weight: 25 Kgs Flow Rate: 35 Lpm Vacuum Gauge: 100Mm Reservoir Volume: 5000Ml Tubing: Non-Collapsible Suction Tubing Max Vacuum: -720Mmhg Motor:½Hp, Fhp 100% Copper Winding Rpm: 1440 Jars: Polycarbonate 2X2.5 Liters Capacity Filter: Bacterial Filter Autoclavable /Reusable Suction Machine Should Be Is I Marked , Fully Automated Biochemistry Analyser Brand (Erba Transia/ Meril) Random Access System With Stat Capability. Analytical Principle Spectrophotometry & Photometry, Turbidometry Principles. Assay Type End Point, Rate, Fixed Point, Kinetic, Ise (Optional). On Board Parameter - Present. Programmable Tests - Present. On Board Cooling For Reagent Present. Through Put - 200 Test/Hour Or More, Continuous Loading Facility. Sample Types Serum, Plasma, Urine & Other Body Fluids. Sample Volume 0-70 Micro Litres (Approx). Sample Quality Analysis, Clot Detection & Probe Crash Protection - Present. Reagent Volume 10 Microlitre To 300 Microlitre (Approx.). Total Reaction Volume 90 Microlitre To 350 Microlitre. Reaction Cuvettes - Permanent Glass Cuvettes With On Board Laundry. Possibility Of Replacement Of Individual Cuvette. Photometric Range 0-3.0 Od. 15. Wavelength-340-800 With Minimum & Standard Wavelengths (340, 405, 505, 546, 578, 600, 700 Nm) Calibration Autocalibration, Cooled Calibration Position, History Of Graphical Calibration Data Stored. Quality Control At Minimum 4 Level Qc Plot Westgard Rules, Twin Plot, Levey Jennings Graph, Cooled Qc Position. Data Storage Of Patient Present Proper System Of Storage Minimum Water Consumption. Warranty 5 Years Warranty Power Back Up Facility For Instrument. Autopipettes To Be Provided With Instrument 10 Micro Litre (Fixed) 01 Nos. 1000 Micro Litre (Fixed) 01 Nos. 0-100 Micro Litre (Variable) 01 Nos. 0-500 Micro Litre (Variable) 01 Nos. 100-1000 Micro Litre (Variable) 01 Nos. Demo Kit With Instrument Reagents Kits Provided With Instrument: Creatinine, Urea Uric Acid, Triglyceride, Sugar Cholesterol, Tp, Albumin, Sgpt, Sgot, Alkaline Phosphatase, Bilirubin Instrument: Usfda Registered And Ce Ivd Approved , Cbc Machine Brand -(Accurex / Erba/ Meril) Measurement Principle Electrical Impedance For Counting Rbc Wsc & Plateletscolorimetric Estimation Of Hgb At 540 Nm Parameterswbc, Ly#, Mid, Gr, Ly%, Mid%, Gr, Rbc, Hgb, Hct, Mcv, Mch, Mchc, Rdw-Cv, Rdw-Sd, Plt, Mpv, Pdw, Pct, P-Lcr, P-Lcc Throughput- 60 Samples/Hour Micro-Aperturewbc: 100 ?M Rbc/Plt:68 ?M Sample Typewhole Blood Or Pre-Diluted Sample Sample Volumewhole Blood (Venous Blood): 10 ?Lpre-Diluent (Capillary Blood) : 20 ?L Chamberdual Chamber: Rbc/Platelets & Wbc/Hgb Reagents- 3 Reagent System: Diluent, Detergent & Lyse (Non-Cyanide) Measurement Range Linearity Range Acceptable Limits Wbc0x10/L-10.0×109/L<= Plus/Minus 0.3 * 10 ^ 9 / L 10.1×109/L-99.9×109/L 0X102/L-1.00×102/L <= (Plus/Minus 5)%<= Plus/Minus 0.05 * 10 ^ 12 / L Rbc 1.01X102/L-9.99X102/L<= (Plus/Minus 5)% Quality Control - 4 Qc Options: L-J, X-B, X-R & X Qc Graphs Plotted With 31 Data Points Data Memory - Upto 100,000 (With Histogram) Display - 10.4 Inch Color Lcd With 640 * 480 Resolution Printer Built-In Thermal Printer Interface:Support Rs-232C, Standard Network Port And Usb; Keyboard And Mouse Operating Environment - Temperature: 15°C-35°C Electrical Specification-Fuse Specification: 250V/3A Humidity: = 85% Rh Frequency: 50/60 Hz Low: 1 X 3Ml/Normal: 1 X 3Ml/High: 1X3 Ml , Sthetoscope Brand- Bpl/Littman , Pulse Oxymeter Brand - Dr Trust /Beurer/ Bpl Specification Finger Chamber With Smart Spring System Accommodates A Wide Range Of Finger Sizes Pop-Up Menu To Setup Alarm Limits For Spo2 And Pulse Rate Low Battery Indicator Pule Rate: Yes Auto Power-Off: Yes Bright, Large Display For Better Visibility In Daylight Anti-Movement Feature Sturdy, Portable And Light-Weight Very Easy To Operate With Single Switch Operation Warranty ( Only Checking Warranty ) , Nebulizer Machine ( Brand -Bpl/Dr Trust) Operation Mode Table Top Size Compact Application Clinical Purpose, Hospital Medicine Cup Capacity 50 Ml Particle Diameter 1-5 Um , Pns ( Pereferal Nerve Stimulator For Nerver Block) Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Should Be Suitable To Identify Peripheral Nerves And Giving Percutaneous Stimulation In Neuro Muscular Block. - Should Have A Percutaneous Monopolar/Bipolar Stimulating Handle For Localization Of Nerves Without Puncturing The Nerve Which Should Be Autoclavable. - Should Have Selectable Stimulation Intensity Ranging From 0-60Ma In Steps 0.1Ma With Stimulating Handle And Stimulation Impulse Width From 0.3Ms, 0.5Ms And1.0Ms - Should Continuously Measure & Display Actual Current Passing Through The Patient And Selected Current -Should Have Pause Function To Interrupt Stimulation Without Delivering Impulses Test Function -Should Automatically Switch Off With A Acoustic Warning If Not Operated Over A Period Of 20 Mins -Should Have Lcd Display For Stimulation Current, Impulse Pattern, Pulse Width, Impulse Amplitude. - Should Have Analog And Digital Display Of Selected Current And Actual Current. - Should Have Membrane Touch Pads For Choosing Stimulation Function -Should Be Small (Pocket Size) & Light Weight. Should Be Ce Certified Or Usfda Certified , Nerve Locator With Needle Brand- B Braun / Vygon Sas/ Stimuplex Hns/2 Separate Output For Nerve Stimulator - Mapper And Locator For Safety. Automatic Switch Over From Mains Power Adaptor To Rechargeable 9Vbattery With Low Battery Warning Indicator. Feather-Touch Keypad For Easy Operation, Simple Setting And Extended Reliability. Variable Current Range As Per The Selected Mode(Impedane:0 To 5 Kohm). User Programmable Pulse Width And Frequency. Alphanumeric Lcd Display With Back Light. Automatic Shutdown For Power Saving. Audio And Back Light On-Off Option. Alarm: Audio-Visual-Alarm Is Activated If Flow Of Oxygen Falls Below 1Lpm. , Percussion Hammer Ss 304 , Tuning Fork 128 Hz Satinless Steel , Laryngoscope A Laryngoscope Is A Device Used In Medical Procedures To Visualize The Trachea By Inserting A Blade With A Small Light Into The Patients Mouth , Oxygen Concentrator Brand- Philips/Bpl/Deck&Mount 1. Flow Rate :-0-5L/Min 2. Purity 93+3% 3. Outlet Pressure(Mpa):-0.04-0.07 4. Sound Level :-<50 Dba , High Flow Nasal O2 Cannula (Brand- Drager / Niceneotech ) High-Flow Nasal Oxygen (Hfno) Therapy Delivers Heated And Humidified Oxygen At High Flow Rates (Up To 60 Liters Per Minute) Through A Nasal Cannula , Electric Needle And Syringe Destroyer Hub Cutter Stainless Steel With Auto-Cut Protection , Clinical Thermometer(Digital) , Medical Labrotary Refrigrator ( Brand- Remi / Vav Intruments) Capacity 600 Litres Temperature Range 2°C To 8°C Internal Configuration Adjustable Shelves And Storage Bins For Optimal Space Utilization Cooling Type Uniform Cooling For Consistent Temperature Distribution Display & Controls Digital Display With User-Friendly Controls Power Supply Energy-Efficient Performance , Refrigrator Domestic Single Door Godrej/ Kelvinator/ Bluestar Capacity 200 Litres To 265 Liters Temperature Range 2°C To 8°C , Wieghing Scale Mannual , Knee Hammer , Sahli,S Heamoglobinometer , Artery Forcef Staright 6 (Brand - Jj Instrument) , Double Hook Retractor Standard Size (Brand - Jj Instrument) , B.P Handleno 3 (Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 4 Mosquito(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 6 Medium(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 8 Long(Brand - Jj Instrument) , Artery Forceps Curved (Fine Tip) 9 Long(Brand - Jj Instrument) , Allies Forceps Big (Brand - Jj Instrument) , Allies Forceps Medium (Brand - Jj Instrument) , Allies Forceps Small (Brand - Jj Instrument) , Mayo Scissior Str 5 ½ Sttilette Edge(Brand - Jj Instrument) , Mayo Scissiorcvd 6 ¼ Sttilette Edge(Brand - Jj Instrument) , Scissors Straight 6 Medium(Brand - Jj Instrument) , Scissors Straight 5 Small(Brand - Jj Instrument) , Scissors Straight 8 Big(Brand - Jj Instrument) , Steinman Pin Introducer Ss(Brand - Jj Instrument) , Towel Clip 6 Big(Brand - Jj Instrument) , Towel Clip 4 Small(Brand - Jj Instrument) , Wire Cutter 9 Standard Size(Brand - Jj Instrument) , Detnal Wire Standard(Brand - Jj Instrument) , Langenbeck Retractor Medium(Brand - Jj Instrument) , Langenbeck Retractor Small(Brand - Jj Instrument) , Langenbeck Retractor Big(Brand - Jj Instrument) , Cats Paw Retractor Standard Size(Brand - Jj Instrument) , K-Wire Cutter With Tungsten Carbide Tip 7 Standard(Brand - Jj Instrument) , Hintermann Distractor Medium(Brand - Jj Instrument) , Mippo Wire Passer For Long Bone Large(Brand - Jj Instrument) , Wire Bender Standard Size(Brand - Jj Instrument) , Kocher Clamp 8 Standard Size(Brand - Jj Instrument) , Glucometer (Brand-Dr Trust / Dr Morphen/Accucheck/Accurex) Fast Result In 5 Seconds Small 0.5Ul Blood Sample Size Large Memory. 10 Lancets Minimum Blood Sample: 0.5 Microlitre ; It Features A Large Display Screen That Can Store Up To 300 Test Results , Vortex Mixture (Brand -Remi /Borosil/ Benchmark) Type Of Product Cyclomixer Shaking Movement Orbital Orbital Diameter (Mm) 4 Motor Type Shaded-Pole Motor , Bio Saftey Cabinet Type-Ii A Microflow (Brand - Microflow / Thermofisher) Specification Material Of Construction (Main Body) Crca/Gi Powder Coated/Stainless Steel 304 Material Of Construction (Work Table) Stainless Steel 304 Dimensions External (Wxdxh) -1950 X 900 X 2250 Mm Internal (Wxdxh) - 1830 X 610 X 610 Mm Average Air Velocity - 90 ± 20% Fpm Hepa/Ulpa - Efficiency 99.997%/99.999% Class Level - Iso 3/5 (Class 100) Noise Level - 65 ± 5 Db Electrical - 230 V, 50 Hz, Single Phase Special Features - Motor Driven Front Door, Alarm, Hepa Filter Blockage, Timer For Uv Light, Power Socket Inside The Cabinet Pressure Sensor Monitoring, Digital Airflow Verification, Interior Eye Level Display, Display Parameters Including Down Flow Air Velocity, Total Operating Hours. Standards Us Fed Std 209 E, Iso 14644-1, Iest-Rp-Cc-002-2, Bsi Certifications- Ce & Iso , Co2 Incubator (Brand - Remi / Thermofisher) Specification Chamber Volume (150 Liters) Sensor Infrared Co2 Heating Method Air-Jacketed, Pid Control Co2 Range 0~20% V/V Co2 Control Resolution ± 0.1% (Ir Sensor) Temperature Range Rt+5~55°C Temperature Stability ± 0.1°C Humidity Method Natural Vaporization > 95% Co2 Recovery (Door Open 30S, Recovery To 5%) = 3 Min Temperature Recovery (Door Open 30S, Recovery To 37°C) = 8 Min Shelves 2 3 Interior Dimension (Mm) (W X D X H) 400 X 450 X 500 480 X 530 X 610 Exterior Dimension (Mm) (W X D X H) 590 X 687 X 790 670 X 767 X 880 Supply:220-240 Volts, 50 Hz Single Phase , Binocular Microscope - Olympus( Model Ch21i) / Magnus (Model- Pzb 22) (Specification) Optical System: - High Contrast Finite Colour Corrected Optical System Magnification:- 40X To 1000X Visual Magnification. Stand: Aluminium Die-Cast Stand With Hand Rests For Enhanced Comfort And Stability. Observation Head: - Sidentopf Binocular/Trinocular Head, 360° Rotatable, Interpupillary Distance 53-75Mm, With Dual Diopteric Adjustment. Eye-Piece: - Wide Field 10X F.O.V 22Mm, Anti-Fungal & Anti- Reflection Hard Coated (Optional 10X/18Mm). Nosepiece: - Reverse Angle Quadruple Nosepiece (Ball Bearing Type) With Precise Click Stops. Objective: - Qusp Series High-Contrast Flat Shield Plan Din Achromatic Objective 4X, 10X, 40X (S) And 100X Oil, (S), Anti-Fungal & Anti-Reflection Hard Coated. Mechanical Stage: - Rack-Less X Axis Double Plate Stage, Size 190 X 125Mm (+-5Mm) With Cross Travel 90 (X) X 50Mm (Y) On Ball Bearing With Co-Axial Controls. Hard Coated Surface For Scratch Resistance. Double Specimen Holder Clip. Focusing Control: - Co-Axial Coarse And Fine Focusing On Gear Systems For Smooth Operation. Fine Adjustment 0.2Mm/Rotation With Maximum 2-Micron Scale Increment. Condenser: - Sub-Stage Moveable Abbe Condenser, Centerable, Na 1.25 With Aspheric Lens. Iris Diaphragm And Special Frosted White Filter, Swing-In, And Swing-Out Filter Holder. Light Source: Led 3.5W 3V Illumination With Variable Illumination Control Universal Power Supply 110V-240V, Ce Approved. Supply With: Power Cable, Immersion Oil, Spare Bulb (In Led Only) User Manual, Vinyl Dust Cover, Cleaning Cloth, And 01 Units Fuses Optional Accessories: - Wooden Carrying Case, Pointers & Micrometre Reticules , Penta Head Microscope(Brand- Micron/Magnus/Weswox) Optical System- Infinite Optical System Viewing Head Inclination 30 Degree, Ipd: 48-75. 01 Piece Trinocular Head, Inclined At 30°, 360° Rotatable, Phototube With 100:0/50:50 Light Split With Sliding Prism. 04 Piece Compensation Free Binocular Head, Inclined At 30°, 360° Rotatable With Diopter Adjustment. Eyepiece-10 Pairs Of Wide Field Eyepiece Wf10x/22Mm Nosepiece- Inverse Quintuple Nosepiece. Objective Plan Achromatic Objective 4X Plan Achromatic Objective 10X Plan Achromatic Objective 20X Plan Achromatic Objective 40X Plan Achromatic Objective 100X Condenser - Swing Out Condenser N.A.0.9/1.25 Focusing-Coaxial Coarse And Fine Adjusting System With Tightness Adjustment And Upper Limited, Coarse Adjustment Range 30Mm. Fine Adjustment Precision: 0.002Mm Attachment- Multi Head Attachment And Support Stand. Stage- Ceramic Coated Double Layers Mechanical Stage Of 185X142 Mm With Capacity To Hold Two Slides At A Time With Slide Catcher On Left And Motion Control On Right Hand Side Illumination- External Illumination, Led 12V 100W Pointer - Multi Colored Ponters With Intensity Controllable Led Colored Indicator (Blue, Green And Red Led) Pointer 360 Rotatable, Brightness Adjustable, Arrow Control Sticks And Color Selection Dial. Video Adapter C Mount 0.5X Camera - 8Mp Hd Camera 4K Resolution With Removable Hd Card With Sd Card And Compatible Software. Display-43 Inch Hd Display Connected To Penta Head Camera For Live Display With Suitable Stabilizer For Display. Certifications - Ce(Notified), Ios 9001 (Iaf Accredited), Ios 13485 Warranty: 1 Year , All In One Pc ( Brand- Hp/Dell/Lenovo) All-In-One Pc 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, 710 White Wireless Keyboard And Mouse Combo (Windows 11 Home, Mso 21, Shell White, 6.72 Kg) 27-Cr0407in , Desktop ( Brand- Hp/Dell/Lenovo) 13Th Gen Intel Core I5 27 (68.6Cm) Fhd 16Gb Ram, 1Tb Ssd, Intel Uma Graphics, Wired Keyboard And Mouse Combo (Windows 11 Home, Mso 21) 27-Cr0407in , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 1.5 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Air Conditioner( Brand- Hitachi/ Bluestar/ Daikin/ Carrier) Ac 2 Ton05star Smart Inverter Ac With Installation & Extra Wire /Pipe , Lithium Battery 1500Wh Battery 48W 120Ah ( Brand- Luminous /Amaron) , Executive Premium Office Chair, Leather “Adjustable Arms Ergonomic Chair Must Behigh Back ( Brand- Godrej) , Office Table4x3 Feet( Brand- Godrej) , Mid Back Office Chiar ( Brand- Godrej) , Revolving Stool ( Brand - Aliza /Godrej) 3 Leg Ss Top Powder Coated Thicknessminimum- 14 Gauge , Steel Almirah W X H X D: 91.44 Mm X 197.866 Mm X 485.140 Feet For Office Use(Brand- Godrej) , Xerox Machine (Hp/Canon/Ricoh) Print Duplex, Copy, Scan, A3 Black And White Laserjet Printer, Enterprise Departments/ Distributed Workforce, Laser Printers Print Speed Is Up To 22 Pages Per Minute (Ppm) For Black And White Printing , Imcubator Electrical 23 Lts Thermostat , Centrifuge Machine Clinical ( Brand - Remi /Benchtop) , Salters Baby Wieghing Machine , Oto Scope , Chloroscope , Horrock,S Appratus Portable , Sound Level Meter Decible Meter With Lcd Display , Water Depth Sampler , Vaccine Carrier , Mosquito Catching Kit , Craft Water Testing Kit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
18.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
19.
Educational and Research Institute #10365642 Price Bid
Tender For Comprehensive Annual Operation And Maintenance Works & Services At Central University Of Rajasthan.; 1 Comprehensive Annual Operation and Maintenance Works & Services 2 SH-I (a) Deployment of Maintenance Gang for day to day Civil Maintenance work at CURAJ 3 SH-I (b) Operation And Maintenance Of 750 KLD Sewerage Treatment Plant at CURAJ 4 SH-II (a) Electrical & Mechanical Preventive And Day To Day Maintenance Works, Annual Operation, Repair, Maintenance And Periodic Servicing Works Of Pump Houses And Annual Electrical Works At CURAJ 5 Annual preventive and day to day maintenance, to upkeep all the electrical internal & external installations, fittings, fixtures, wiring, Lights, Fans, Geysers etc. functional in the CURAJ campus, for all days in a month, including Sundays and Holidays, including manpower, labour, machinery, general maintenance items, tools & tackles for all deputed staff, safety tools for LT & HT power supply, various type of ladders/tipaya/chopaya etc. as required on site, complete in all respects, as per standard practice. Indicative items are as under: • Wiring/Cabling.• Metal/PVC boxes.• Switches, sockets and accessories of different ratings.• 01phase/03 phase power points & circuits.• 01/03 phase Energy Meters.• Light points/ Fan pts/ Exhaust Fan pts/Call bell pts. etc.• All type of indoor and outdoor lights (conventional/LED/HPSV/MVSV etc.) fittings.• All type of fans (Ceiling/Exhaust/pedestal/wall).• HVLS fans.• Water heaters.• Auditorium stage lights.• Air curtains and electric fly catchers.• Rising mains bus trunking and overhead bus bar of different ratings.• Sandwich rising mains with aluminium bus bar of different ratings.• Switch, disconnector, SFU and MCCB of different ratings.• MCBs, Isolators, RCCBs and MCB DBs of different ratings.• Cable and Boxes of different sizes.• Brass compression glands of different sizes.• Aluminium lugs of different sizes.• HT/LT Cable fault detections and jointing kits.• Overhead electric line.• Road lights.• Lightning arrester and earthing system.• All Electrical indoor and outdoor panels and panel rooms of all buildings.• Maintenance of records etc. and as per tender document. 6 Comprehensive Annual Electrical Operation, Repair, Maintenance and Periodic Servicing Works of pump houses and other water & booster pumps/motors/starters along with associated panels and accessories for all days in a month including Sundays and Holidays, including manpower, machinery, spare parts, consumables, tools & tackles for all deputed staff, safety tools for LT power supply, ladders, ropes etc. as required on site, complete in all respects.Note: Tentative quantity of motors & pumps of different ratings is 30. 7 Providing of uniform to all the deputed staff with reference to (a & b) above, as prescribed by the University and as per tender document. 8 CPWD DSR (E&M) 2022/Chapter-01: Wiring.The bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 5,00,000/- 9 CPWD DSR (E&M) 2022/Chapter-02: MCCB, MCB, DBs.The bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 1,00,000/- 10 CPWD DSR (E&M) 2022/Chapter-05: EarthingThe bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 1,00,000/- 11 Detection of fault in underground electric Low Tension (LT)/High Tension (HT) cable incl. fault detection machine charges, digging & labour charges etc. complete in all respects as per standard practice. 12 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor LT cable of 1.1 KV grade as required. 13 3½ X 25 sq. mm 14 3½ X 35 sq. mm 15 3½ X 50 sq. mm 16 3½ X 70 sq. mm 17 3½ X 95 sq. mm 18 3½ X 120 sq. mm 19 3½ X 150 sq. mm 20 3½ X 185 sq. mm 21 3½ X 240 sq. mm 22 3½ X 300 sq. mm 23 3½ X 400 sq. mm 24 4 X 16 sq. mm 25 Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor HT cable of 11 KV grade as required : 26 70 sq. mm 27 120 sq. mm 28 185 sq. mm 29 240 sq. mm 30 300 sq. mm 31 400 sq. mm 32 General inspection & patrolling of about 10 km long overhead HT/LT lines feeder wise for identification of maintenance work to be carried out i/c strengthing of cross arms with clamps including tightening of nut bolts, removal of birds nest and foreign material from line along with tree/bush trimming under these lines. (to be carried out before starting of summer season and as per the requirement). 33 Annual Servicing of Fans (Ceiling/Exhaust/Wall/Pedestal etc.) installed in various buildings of the University i/c checking the unit with accessories for functionality tests, replacement of nut-bolts & locking pins/clips wherever reqd, oiling/greasing, cleaning, pasting of service/repair slips on fan and any other minor repair works required on site i/c labour, tools & takels charges as per standard practice and directions of EIC. Note: 1) This work also includes replacement of spare parts of fans like condensors, regulators, fan hooks as required during servicing and these spare parts will be provided by the University.2) This work excludes all major repair works like rewinding, replacement of bush/bearing etc. 34 Copper rewinding of existing burnt fans (Ceiling/ Exhaust/Wall/Pedestal Fans) under buyback of old copper incl. handling charges etc. as per standard practice. 35 Replacement of parts like bush/bearing etc. with new one of same size/rating under buyback of faulty one as per standard practice incl. handling charges. 36 Repairing of rotor/stator/shaft etc. of fans as required as per standard practice incl. handling charges. 37 Comprehensive AMC Work of Online UPS(s) of different ratings installed in various buildings of CURaj 38 Comprehensive AMC Work of Online UPS(s) of different ratings installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects excluding replacement of batteries.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 39 14 Nos. 1 kVAOnline UPS 40 08 Nos. 2 kVA to 3 kVA Online UPS 41 08 Nos. 5 kVA to 6 kVAOnline UPS 42 02 Nos. 10 kVA Online UPS 43 06 Nos. 15 kVA to 20 kVA Online UPS 44 02 Nos. 40 kVA Online UPS 45 Replacement of following capacity faulty/dead SMF rechargeable batteries with new batteries of same rating/capacity along with connections, testing and commissioning etc. as required on site as per standard practice, under buyback offer. Make: Exide/Amaron/Luminous/HBLWarranty:minimum 02 years onsite or as per OEM, whichever is higher. 46 18 AH, 12 V 47 26/28 AH, 12 V 48 42/45 AH, 12 V 49 65 AH, 12 V 50 75 AH, 12 V 51 120 AH, 12 V 52 150 AH, 12 V 53 Comprehensive AMC Work of 86 Nos. Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj 54 Comprehensive AMC Work of 86 Nos. Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects.Note: This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing and unlimited breakdown calls through qualified & experienced persons. 55 Repairing of 45 Nos. faulty Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 56 SH-II (d) Comprehensive AMC Work of HVAC System (Ductable / VRV-VRF / Cassate / Split / Tower / Window Type Air Conditioners and ETAC System) installed in various buildings of CURajComprehensive AMC Work ofHVAC System (Ductable / VRV-VRF / Cassate / Split / Tower / Window Type Air Conditioners and ETAC System) installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice and directions of Engineer-in-Charge.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 57 100 hp rated inverter technology based VRV/VRF type Air Conditioning System installed in CIL Building. Make: Hitachi 58 40 hp rated inverter technology based VRV/VRF type Air Conditioning System installed in VCS, Admin Building. Make: Hitachi 59 04 Nos. 11.0 TR capacity Ductable Air conditioning units with Scroll Compressor with R 410 A Refrigerant, vibration isolators etc. complete. Make: Hitachi 60 03 Nos. 5.5 TR capacity Ductable Air conditioning units with Scroll Compressor, R 410 A Refrigerant, vibration isolators etc. complete. Make: Carrier 61 03 Nos. Ceiling-mounted 3.0 TR Cassette Air Conditioning units complete. Make: Bluestar 62 400 Nos. Window/Split/Tower type air conditioners. 63 02 Nos. 30000 CFM, Air ducting system (ETAC) 64 04 Nos. 28000 CFM, Air ducting system (ETAC) 65 02 Nos. 10000 CFM, Air ducting system (ETAC) 66 02 Nos. 4000 CFM, Air ducting system (ETAC) 67 Repairing of faulty 100 Nos. Split ACs, 10 Nos. Tower Air-conditioners and 01 No. 5.5 TR Ductable AC, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 68 SH-II (e) Comprehensive Annual Operation, Repair and Maintenance of 04 Nos. 11/0.433 kV electric sub-stations and 05 numbers DG Sets at CURaj. 69 Comprehensive Annual Operation, Repair and Maintenance of 04 Nos. 11/0.433 kV electric sub-stations and 05 numbers DG Sets along with associated panels etc. through OEM/Authorized Service Agents of OEM only, including manpower for operational purpose, labour, machinery, spare parts, Control Panel/DG Set Batteries, consumables, tools & plants etc. complete in all respects, as per standard practice and directions of Engineer-in-Charge.Note: 1) This work includes operators in all three shifts on 24*7*365 basis at each ESS.2) This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing i/c all B/C/D checks and unlimited breakdown calls through qualified & experienced persons, as per OEM’s standard guidelines & service manuals. 70 SH-II (f) Comprehensive Annual Operation (in general shift), Repair and Maintenance of 14 nos. Johnson make, machine room less passenger lifts at CURaj. 71 Comprehensive Annual Operation (in general shift), Repair and Maintenance of 14 nos. Johnson make, machine room less passenger lifts along with associated panels etc. through OEM/Authorized Service Agents of OEM only, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note:1) This work includes one lift operator in general shift on 24*7*365 basis in Admin Building.2) This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing and unlimited breakdown calls through qualified & experienced persons, as per OEM’s standard guidelines & service manuals. 72 SH-III Comprehensive Annual Repair & Maintenance Work of Fire Hydrant System and Fire Alarm System installed at CURaj. 73 Comprehensive Annual Repair & Maintenance Work of all Fire Hydrant System installed in various building of the University (tentative buildings = 30 nos.) as specified in Schedule of Work, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 74 Comprehensive Annual Repair & Maintenance Work of all Fire Alarm System and associated equipment installed in various building of the University as specified in Schedule of Work, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 75 Repairing of existing non-functional Fire Hydrant System including associated equipment, installed in B1 to B7 Hostel buildings, KV Building and B/C/D type Staff Quarter Blocks of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 76 Repairing of existing non-functional Fire Alarm System including associated equipment, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 77 SH-IVComprehensive Annual Maintenance Contract for RO Plants/Purifiers. 78 The scope of work includes comprehensive annual maintenance and servicing of RO Plants/Purifiers and submitting a report after every visit. The scope of work includes checkup of each Unit/system and general cleaning, chemical cleaning of cartridge, if required, replacement of all type of membrane, all type of filters, all pipes, S.V., TDS Controller, all type of sensors, pump etc. as per requirements of the University during the CAMC Period. 79 Supply and Installation (under buy back) of Reverse Osmosis Plant of 50 LPH Capacity Make Eureka ForbesNote: Old Reverse Osmosis Plant of 50 LPH Capacity - Make Eureka Forbes will be the property of the Contractor. Hence contractor may be advised to quote their rates accordingly. 80 SH-VComprehensive Operation and Maintenance of IT Works. 81 Comprehensive Operation and Maintenance of installations IT Works (Operation & CAMC of Audio & Video Conferencing System, Networking items for LAN and Wi-Fi systems like Switches, Active & Passive network components, Smart class rooms Equipments including PA systems, Hardware and software maintenance of Computers, Laptops, Printers, Projectors, Servers), CCTV Systems. as per the details given below: 82 Hardware Items 83 Laptops : 84 Desktop System: 85 Server: 86 Printers: 87 LCD Projector: 88 CCTV System 89 IP Camera 90 DVR Camera 91 Switch (24 port) 92 Switch (8 port) 93 Switch (4 port) 94 42 Screen 95 32 Channel NVR 96 8 Channel NVR 97 4 Channel NVR 98 Surveillance Hard Disk 10 TB 99 Surveillance Hard Disk 4 TB 100 Surveillance Hard Disk 2 TB 101 Biometric Access Control Systems 102 Face Biometric Machine 103 Voice System 104 IP-PBXMachine 105 IP Phone 106 IP Phone DSS KEY 107 Data Networking System 108 Switch(48 Port) 109 Switch (24 Port) 110 Core Switch 111 LAN points 112 Audio Video Conferencing System 113 Group Video Conferencingdevice including camera, speakerphone with USB plug-and-play connectivity 114 PTZ Video Conferencing Camera 115 Smart Classrooms System including PA System 116 Smart Classroom equipped with, interactive screen 75/86 inch, audio systems, digital podium with mini PC, PTZ cameras and other related items 117 SH-VI Comprehensive Maintenance of Horticulture and operation & maintenance of Drip Irrigation System. 118 Horticulture Manpower in General Shift in all days except Sundays and holidays (Unskilled). All tools tackles shall be arranged by contractor within its quoted rates.• Complete maintenance of Trees, Plants and peripherals, shrubs, hedge, lawns, (Including cricket ground, hockey ground and football ground etc.) cemented potted plants, flower beds, creepers etc. within the campus of the Central University of Rajasthan.• Maintenance includes weeding, pruning, gap filling, watering, mowing of lawn, hoeing, hedge-clipping, application of insecticide & pesticide, top dressing of lawn with good earth and manure including other maintenance work as directed by the University from time to time.• Fertilizers, Manures, plant protection materials etc. will be provided by the contractor nothing extra shall be paid in this regard.Maintenance of Drip Irrigation System, (water sprinkler system installed at cricket, football and hockey grounds and another places of the University etc.) periodical checking of the system cleaning, oiling, greasing, routine maintenance, realignment, necessary safety arrangements & repair/ replacement of consumables such as Super flow screen filters, Gravel filters, Pressure relief valve, Non return valve, stainless steel pressure gauges,by pass valve PP, PVC control/ball valves, sub main flush valve, Reinforced nylon air release valve CPVC gate valves, super flow disc clean filters, PVC pipes and fittings etc. as per direction of Engineer-in-charge. This shall include all cost involved in maintenance except for electricity for operation, which shall be provided by the University free of cost. 119 SH-VIIMechanized Housekeeping Services, Garbage Collection & Disposal Services, and Pest Control Services at CURAJ. 120 ProvidingMechanized House Keeping Service include machine enabled cleaning, sweeping, wiping, dusting, moping, freshening, garbage collection, segregation & disposal, vacuum cleaning, scrubbing and any other similar tasks as assigned by CURAJ authorities from time to time.Consumable, like duster, Soap, chemicals, wipers, Phenyl and other cleaning materials for toilets and floor required as indicated in list under the scope of work etc.All façade glass should be cleaned once in a month including glass doors and windows.Providing pest Control Services, Rodent Control Services, Fogging & Fumigation against mosquito & larva, Fly management services, termite treatment etc. as per tender terms and conditions and directions of the University. 121 Termite Treatment: Termite treatment in the University based on IS:6313(Part-3)-1981 specification which consists of creating uninterrupted chemical barriers inside and all around the building. The treatment should be drill holes of 6mm as close as possible to the plinth, walls, junctions of the walls at an interval of 6 inches enough to reach the soil below 6 inches deep. Then chemical emulsion should be injected into these holes, which should be subsequently sealed using white cement match with floor colour all complete , The wall should be spray the chemical emulsion up to roof height wherever required complete. 122 SH-VIII Hiring Manpower with fixed remuneration through outsourced agency at CURaj. 123 Service charges per month per person(To be quoted for deciding the lowest responsive bid to award the work)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
20.
Housing Urban and Rular Development #10332311 Price Bid
Tender For Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M (One Point Five Metre ) In Width Or 10 Sqm ( Ten Square Metre ) On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, (One Point Five Metre ) Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan),Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Gettingout The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed With In Any Lead .Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundationsetc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Up To Any Leadwithin Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4(One Cement : Two Coarse Sand): Four Graded Stone Aggregate 40 Mm ( Forty Millimetre ) Nominal Size) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying In Position Cement Concrete Of Specified Grade In Parapets Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4(One Cement : Two Coarse Sand): Four Graded Stone Aggregate 40 Mm ( Forty Millimetre ) Nominal Size) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 (One Cement : Four Coarse Sand): Eight Graded Stone Aggregate 40 Mm ( Forty Millimetre ) Nominal Size) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , A) Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , D) Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers , Steel Work In Built Up Section Trusses And Framed Work Including Hosting Fixing In Position And Applying A Priming Coat Of Red Lead Paint As Per Direction Of Engineer-In-Charge.In Gratings, Frames, Guard Bar, Ladder, Railings, Brackets, Gates And Similar Works Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Applying Priming Coat: With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron/ Steel Works Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Supplying At Site Angle Iron Post & Strut Of Required Size Including Bottom To Be Split And Bent At Right Angle In Opposite Direction For 10 Cm Length And Drilling Holes Upto 10 Mm Dia. Etc. Complete. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing G.I. Chain Link Fabric Fencing Of Required Width In Mesh Size 50X50 Mm Including Strengthening With 2 Mm Dia Wire Or Nuts, Bolts And Washers As Required Complete As Per The Direction Of Engineer-In-Charge. Made Of G.I. Wire Of Dia 4 Mm, Pvc Coated To Achieve Outer Dia Not Less Than 5 Mm In Required Colour And Shade.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Portable Barricades , Supply Of Portable Steel Fabricated Barricade Stand Metal Barricade Stand Manufacturer And Dealers Specification: Size: 1800Mmlx1200mmcolour: Yellow Number Of Wheels: 4 Numbers (75Mm Dia) Pipe Dia: 40Mm Pipe Gauge: 16 Gauge Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Boom Barrier & Tyre Killer , Supply Installation Testing & Commissioning Of Boom Barrier Of 4 Mtr. Length Of Boom Arms. Galvanised And Ral Painted With Buil In Control Panel With Intensive Use. Manual Open / Close Buttons And Automatic Closing Ir Device Complete With Ground Loop Detection Board (For Entrance And Exit To The Main Building),100% Duty Cycle.High Intensive Use Dc Barrier. 180-200Nm Operating Torque For. 2 Sec Open/Close Time . Motor Current Draw : 12A. Max Motor Power: 300W.Max Opening : 90 Degree.Ip54. Inter-Changeable Barrier( Left To Right And Vice Versa). Ampereomatic Feature For High Safety In Case Of Failure Of Safety Device. Complete As Required As Per Given Technical Specification.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Supply Installation Testing & Commissioning Of Portable Spike Barieer Tyre /Killer Suitable To Work On Manual Operation .The Main Frame Is Made Of 6Mm Thick Flat Aluminum Strip Which Made It Corrosion Resistant,Strong And Light In Weight For Easy Portability & Long Durability. Other Details Are As Below, A. Portable Tyre Killer - 4 Mtr. B. Edge Of Spike - 10Mm,C. Height Of Spike - 60Mm,D. No. Of Spikes - 85 Nos.E. Total Weight : 7 Kg. (Approx.)F. No. Of Wheels In Packing Box - Two Etc.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying In Position Machine Batched And Machine Mixed Design Mix Providing M-25 Grade Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. Note :- (Note:- Cement Content Considered In M-25 Is @ 330 Kg/Cum) All Works Upto Plinth Level , All Works Upto Plinth Level , All Works Above Plinth Level Upto Floor V Level , Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Including Cost Of Binding Wire Upto Plinth Level As Per The Directions Of Engineer-In-Charge Including Carriage Of Materials With In All Leads, Lifts And Other Incidentals . Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Structural Steel Work Riveted ,Bolted Or Welded In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Columns, Pillars, Piers, Abutments, Posts And Struts Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With 1:1.5:3 (1 Cement : 1.5 Coarse Sand) : 3 Graded Stone Aggregate 20 Mm Nominal Size). Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Coarse Sand) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Painting Two Or More Coats On Brick Wall/Rcc Wall/ Masonary Wall At All Locations Prepared And Applied As Per Manufacturers Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete. On Steel Work Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Colour Coated Galvalume Trapezoidal Profiled Sheeting Of 0.50Mm Thickness Tolerance +/-5% Total Coated Thickness Tct Of Material 550 Mpa For Roofing/ Cladding Application. The Trapezoidal Profiled Sheet Shall Be 28-32 Mm In Crest Height With 2 Stiffener Ribs With Subtle Square Fluting In The Six Pans At Nominal 200 Mm Centre- To-Centre. The End Crest Shall Be Designed For Anti - Capillary Action , To Avoid Any Seepage Of Water Through The Lateral Overlap. The Profile Shall Have Return Leg For Proper Side Lap. Coating Specification: Primer Coat: 5-7 Microns Epoxy Primer On Both Side Of Sheet. Top Coat: Polyester Top Coat 15 -18 Microns. Color: As Approved By Engineer-In-Charge Tolerances: As Per Is Standards: Is: 15961, Is: 513, Is: 14264. The Sheet Shall Be Fixed Using Self Drilling /Self Tapping Screws Of Size (5.5X 55 Mm) With Epdm Seal, Complete Upto Any Pitch In Horizontal/ Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Same As Above But For Ridges Plain (500 - 600Mm) , Same As Above But For Gutter .(600 Mm Over All Girth) , Finishing With Deluxe Multi Surface Paint System For Interiors And Exteriors Using Primer As Per Manufacturers Specifications :Painting Steel Work With Deluxe Multi Surface Paint To Give An Even Shade. Two Or More Coat Applied @ 0.90 Ltr/10 Sqm Over An Under Coat Of Primer Applied @ 0.80 Ltr/10 Sqm Of Approved Brand And Manufacture Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Preparation And Consolidation Of Subgrade With Power Road Roller Of 8 To 12 Tonne Capacity After Excavating Earth To An Average Of 22.5 Cm Depth , Dressing To Camber And Consolidating With Road Roller Including Making Good The Undulations Etc. And Re-Rolling The Subgrade And Disposal Of Surplus Earth With Lead Upto 50 Metres.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Dry Stone Pitching 22.5 Cm Thick Including Supply Of Stones And Preparing Surface Complete.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Applying Prime Coat Using Bitumen Emulsion Conforming To Is: 8887, Using Emulsion Pressure Distributer Including Preparing The Surface & Cleaning With Mechanical Broom. With Medium Setting Bitumen Emulsion On W.B.M / W.M.M. @ 0.4Kg/Sqm Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Applying Tack Coat Using Bitumen Emulsion Conforming To Is: 8887, Using Emulsion Pressure Distributer Including Preparing The Surface & Cleaning With Mechanical Broom. With Medium Setting Bitumen Emulsion On Bituminous Surface @ 0.25Kg/Sqm Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Painting Runway/Taxi Track/Apron Marking With Adequate Nos Of Coats To Give Uniform Finish With Road Marking Paint Of Superior Make As Approved By The Engineer-Incharge, I/C Cleaning The Surface Of Oil , Dirt , Scales , Oil , Grease And Other Foreign Mater;Al Etc. And Lining Out Complete. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Painting Road Surface Marking With Adequate Nos Of Coats To Give Uniform Finish With Ready Mixed Road Marking Paint Conforming To Is : 164, On Bituminous Surface In White/Yellow Shade, Including Cleaning The Surface Of All Dirt, Scales, Oil, Grease And Foreign Material Etc. Complete. New Work (Two Or More Coats) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying Dense Graded Bituminous Macadam Using Crushed Stone Aggregates Of Specified Grading, Premixed With Bituminous Binder And Filler, Transporting The Hot Mix To Work Site By Tippers, Laying With Paver Finisher Equiped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers As Per Specifications To Achieve The Desired Compaction And Density, Complete As Per Specificatons And Directions Of Engineer-In-Charge. 50 To 100 Mm Average Compacted Thickness With Bitumen Of Grade Vg-30 @ 5% (Percentage By Weight Of Total Mix) And Lime Filler @ 2% (Percentage By Weight Of Aggregate) Prepared In Batch Type Hot Mix Plant Of 100-120 Tph Capacity.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying Bituminous Concrete Using Crushed Stone Aggregates Of Specified Grading, Premixed With Bituminous Binder And Filler, Transporting The Hot Mix To Work Site By Tippers, Laying With Paver Finisher Equiped With Electronic Sensor To The Required Grade, Level And Alignment And Rolling With Smooth Wheeled, Vibratory And Tandem Rollers To Achieve The Desired Compaction And Density As Per Specification, Complete And As Per Directions Of Engineer-In-Charge. 40/50 Mm Compacted Thickness With Bitumen Of Grade Vg-30 @ 5.5% (Percentage By Weight Of Total Mix) And Lime Filler @ 3% (Percentage By Weight Of Aggregate) Prepared In Batch Type Hot Mix Plant Of 100-120 Tph Capacity.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying 60Mm Thick Faciory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size,Design & Shape, Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Line Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing, Laying, Spreading And Compacting Graded Stone Aggregate (Size Range 53 Mm To 0.075 Mm ) To Wet Mix Macadam (Wmm) Specification Including Premixing The Material With Water At Omc In For All Leads & Lifts, Laying In Uniform Layers With Mechanical Paverfinisher In Sub- Base / Base Course On Well Prepared Surface And Compacting With Vibratory Roller Of 8 To 10 Tonne Capacity To Achievethe Desired Density, Complete As Per Specifications And Directions Of Engineer-In-Charge.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M. All Kinds Of Soil. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M. All Kinds Of Soil.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soilwithin Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. , Extra For Every Additional Lift Of 1.5 M Or Part Thereof In Excavation / Banking Excavated Or Stacked Materials. All Kinds Of Soil Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Prepainted Sandwich Puffed Roofing With Top Skin Of 0.60 Mm Thick Prepainted Steel Sheet Over Steel Trusses Made Of Cold Rolled Steel Coil With Epoxy Coating Of 25 Micron Having A Puff Depth Of 50 Mm Rock Wool And Wt. Of Puff 35 To 37 Kg Per Cum. And Interior Skin Of 0.50 Mm Prepainted Steel Sheet Steel Frames Are To Be Painted Of Approved Shade I/C Fixing With Self Drilling And Self Tapping Galvanizedoz Or Zinc Alloy Coated Fasteners Of Sizes 5.5 Mm Dia And 55 Mm Long With Epdm Seal , Wahsers Complete With All Accessories As Required And As Per The Specification And Direction Of Engineer - In - Charge Including Carriage Of Materials With In All Lead And Lift And Other Incidentals . Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing Ridges Or Hips Of Width 60 Cm Overall Width Plain G.S. Sheet Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8 Mm Dia G.I. Limpet And Bitumen Washers Complete. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² , Providing And Fixing 15Cm Wide ,45 Cm Over All Semi-Circular Plain G.S.Sheet Gutter With Iron Brackets 40X3 Mm Size , Bolts ,Nuts And Washers Etc., Including Making Necessary Connections With Rain Water Pipes Complete. 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gm/M² Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Finishing With Epoxy Paint (Two Or More Coats )At All Locations Prepared And Applied As Per Manufacturers Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete.On Steel Work Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Supplying And Stacking At Site. Good Earth Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Supplying Chemical Emulsion In Sealed Containers Including Delivery As Specified. Chlorpyriphos/ Lindane Emulsifiable Concentrate Of 20% Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Making Plinth Protection With Local Stone / Slate Embedded In 50Mm Thick Of Cement Concrete 1:3:6 (1 Cement : 3 Coarse Sand (Zone - Iii) : 6 Graded Stone Aggregate 20 Mm Nominal Size) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying Damp-Proof Course 40 Mm Thick With Cement Concrete 1:2:4 (1Cement : 2 Coarse Sand): 4 Graded Stone Aggregate 12.5Mm Nominal Size) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7 Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Clothlightly Soaked In Kerosene Oil. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Extra For Providing And Mixing Waterproofing Material In Cement Concrete Work In Doses By Weight Of Cement As Per Manufacturers Specification. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing 18 Mm Thick Gang Saw Cut,Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills,Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment,Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc .Complete At All Levels:Granite Of Any Colour And Shade Area Of Slab Upto 0.50 Sqm Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing Edge Moulding To 18 Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is:2202 (Part I) Non-Decorative Type , Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Commercial 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters:35 Mm Thick Including Isi Marked Stainless Steel But Thinges With Necessary Screws Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Aluminium Sliding Door Bolts Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc. Complete. 300X16 Mm Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Aluminium Tower Bolts Isi Marked Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc. Complete: 300X10 Mm Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Aluminium Handles, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete : 125 Mm Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised (Anodic Coating Not Less Than Grade Ac10 As Per Is: 1868) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. Twin Rubber Stopper Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Bright Finished 100 Mm Mortice Lock With 6 Levers Without Pair Of Handles Of Approved Quality For Aluminium Door, With Necessary Screws Etc Complete As Per Direction Of Engineer- In-Charge. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing & Fixing Decorative High Pressure Laminated Sheet Of Plain / Wood Grain In Gloss / Matt/ Suede Finish With High Density Protective Surface Layer And Reverse Side Of Adhesive Bonding Quality Conforming To Is : 2046 Type S, Including Cost Of Adhesive Of Approved Quality.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters (Over All Area Of Door Shutter To Be Measured).Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Aluminium Extruded Section Body Tubular Type Universal Hydraulic Door Closer (Having Brand Logo With Isi , Is:3564 ,Embossed On The Body,Door Weight Upto 36 Kg To80 Kg And Door Width From 701 Mm To1000 Mm),With Double Speed Adjustment With Necessary Accessories And Screws Etc. Complete. , Structural Steel Work Riveted ,Bolted Or Welded In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete.Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Carbon Steel Galvanised (Minimum Coating 5 Micron) Dash Fastener Of 10 Mm Dia Double Threaded 6.8 Grade (Yield Strength 480N/Mm2), Counter Sunk Head, Comprising Of 10Mdia Polyamide Pa6 Grade Sleeve, Including Drilling Of Hole In Frame , Concrete/Masonry, Etc. As Per Direction Of Engineer-In-Charge Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Kota Stone Slab Flooring Over 20Mm (Average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1:4(1 Cement : 4 Coarse Sand) : 25 Mm Thick Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Kota Stone Slabs 20Mm Thick In Risers Of Steps , Skirting ,Dado And Pillars Laid On 12Mm (Average) Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Distempering With 1St Quality Acrylic Distemper, Having Voc (Volatile Organic Compound ) Content Less Than 50 Grams/ Litre, Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required, To Achieve Even Shade And Colour. Two Coats Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , 12 Mm Cement Plaster To Ceiling In Cement Mortar 1:6 (1 Cement: 6 Coarse Sand) As Per The Directions Of Engineer-In-Charge Including Carriage Of Materials Within All Leads, Lifts And Other Ncidentals.1:6 (1 Cement: 6 Coarse Sand) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , 20 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Coarse Sand) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Finishing Walls With Textured Exterior Paint Of Required Shade : New Work(Two Orn More Coats Applied @ 3.28 Ltr/10Sqm) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg/10 Sqm Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Finishing With Epoxy Paint (Two Or More Coats )At All Locations Prepared And Applied As Per Manufacturers Specifications Including Appropriate Priming Coat, Preparation Of Surface, Etc. Complete.On Steel Workwithin Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. (Glazing, Paneling And Dash Fasteners To Be Paid For Separately) : For Fixed Portion Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required (Fittings Shall Be Paid For Separately) Anodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac 15) , Providing And Fixing Double Glazed Hermetically Sealed Glazing In Aluminium Windows, Ventilators And Partition Etc. With 6 Mm Thick Clear Float Glass Both Side, Having 12 Mm Air Gap, Including Providing Epdm Gasket, Perforated Aluminium Spacers, Desiccants, Sealant (Both Primary And Secondary Sealant) Etc. As Per Specifications, Drawings And Direction Of Engineer-In-Charge Complete. , Filling The Gap In Between Aluminium Frame & Adjacent Reinforced Cement Concrete / Brick / Stone Work By Providing Weather Silicon Sealant Over Backer Rod Of Approved Quality As Per Architectural Drawings And Direction Of Engineer-In-Charge Complete. Upto 5Mm Depth And 5 Mm Width Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights : Suspended Floors, Roofs, Landings, Balconies And Access Platform Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For All Heights :Edges Of Slabs And Breaks In Floors And Walls: Under 20Cm Wide. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying Integral Cement Based Treatment For Water Proofing On Horizontal Surface At All Depth Below Ground Level For Under Ground Structures As Directed By Engineer-In-Charge And Consisting Of : (I) Ist Layer Of 22 Mm To 25 Mm Thick Approved And Specified Rough Stone Slabover A 25 Mm Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Mixed With Water Proofing Compound Conforming To Is:2645 In The Recommended Proportion Over The Leveling Course (Leveling Course To Be Paid Separately). Joints Sealed And Grouted With Cement Slurry Mixed With Water Proofing Compound. (Ii) 2Nd Layer Of 25 Mm Thick Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Mixed With Water Proofing Compound In Recommended Proportions. (Iii) Finishing Top With Stone Aggregate Of 10 Mm To 12 Mm Nominal Sizespreading @ 8 Cudm/Sqm Thoroughly Embedded In The 2Nd Layer. Using Rough Kota Stone. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Laying Integral Cement Based Treatment For Waterproofing On The Vertical Surface By Fixing Specified Stone Slab 22 Mm To 25 Mm Thick With Cement Slurry Mixed With Water Proofing Compound Conforming To Is:2645 In Recommended Proportions With A Gap Of 20 Mm (Minimum) Between Stone Slabs And The Receiving Surfaces And Filling The Gaps With Neat Cement Slurry Mixed With Waterproofing Compound And Finishing The Exterior Of Stone Slab With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand ) 20 Mm Thick With Neat Cement Punning Mixed With Waterproofing Compound In Recommended Proportion Complete At All Levels And As Directed By Engineer-In-Charge : Using Rough Kota Stone Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honeycomb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter , 1.8 M Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Providing And Placing In Position Suitable Pvcwater Stops Conforming To Is:12200 For Construction / Expansion Joints Between Two Reinforced Cement Concrete Members And Fixed To The Reinforcement With Binding Wire Before Pouring Concrete Etc. Complete : Dumb Bell With Central Bulb (180 Mm Wide, 8 Mm Thick) Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst. , Construction Of Pre-Fabricated Cabin Size (12.00X5.00X5.00)Mtr Roof Hut Shape As Per Dreawing.Specifications:- A) Outer Wall 50Mm Thick Wall Puf Insulated Panel.B) Roof Panel (30/70)Mm Thick Puf Panelc) Door And Window (As Per Drawing) Upvc.D) Ppgi Flashings (U-Channel & Corners).E) Hardware & Accessories.F) Erection Of Wall And Roof Panel.G) Tile Flooringh)Pvc Ceilingincluding All Civil Work Required I.E Foundation, Footing, Plinth Beam Etc, Office, Toilets,Electrical Work ,Hvac,Fire Fighting,Plumbing & Sanitation,Earthing,Over Head Tank 5,000 Ltr, Septic Tank Etc As All Required Work Completed Including Carriage Of Material In All Leads And Lifts As Per The Direction Of Engineer-In-Charge. Within Any Lead .Ithin All Leads And Lift Including Carriage Of Materials And As Per Direction Of Engineer-In- Charge. The Rate Is Including Octroi, Royality, Malkana, Toll Tax, Or Any Other Taxes Imposed By The Government Excluding Gst.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Himachal Pradesh View Result →
21.
Public Administrative Department #10027101 Technical Bid
Tender for Item-Wise Rates Of Various Non-Schedule Items For Different Development Works / Renovation Of Conference Hall Of Paradeep Municipality. , Supply, Installation, Testing And Commissioning Of Electric High Speed Light Weight 50W 400 Mm Wall Fan Of White Colour Is A Space-Saving And Efficient Cooling Solution Designed For Optimal Air Circulation In Both Residential And Commercial Settings. Mounted On A Wall, These Fans Offer A Directed And Localized Breeze, Making Them Ideal For Spaces Where Floor Space Is Limited Or Where A Targeted Airflow Is Desired. Specification: Dimensions - 49.2D X 77.8W X 46.9H Centimeters, Noise Level-63 Db, Glossy Finish, Number Of Blades-01, Air Flow Capacity- 72 Cubic Meters Per Minute, Blade Length-400 Millimeters, Speed- 1.36E+3 Rpm, 230 Volts, Remote Type, Specification Met- Ce. Make- Havells/ Cg/ Bajaj , Supply, Installation, Testing And Commissioning Of Electric Single Phase Exhaust Fan 12Inch. Specification: 300Mm Exhaust Fan | Strong Air Suction, Rust Proof Body |Suitable For Bathroom, Kitchen, And Office. Product Dimensions 42D X 42W X 21.5H Cm, Special Feature Portable, Water Resistant, Waterproof. Make- Havells/ Cg/ Bajaj , Supply And Installation, Testing & Commissioning Of 5Kva (1Ph-1Ph) Online Double Conversion Ups Having 1Ph-1Ph With Inbuilt Isolation Transformer, With Ms Rack Rack , Dc Cable, Links With Two Years Warranty. With Back Up Of 60 Minutes. Make : Numeric - Legrand/ Delta/ Vertive Battery: For 60 Minutes Battery Back , Ms Rack, Linkd Dc Cable And Battery 12V/42Ah/16Nos.. Minimum Vah Reqd. 10080 Vah. Make-Exide Quanta / V-Guard/ Luminous , Water Purifier: Supply Of Ro Water Purifier 5 Stage Filtration, 50-55 Ltr/Hr. Capacity. Make- Lexpure/ Kent/ Livpure , Water Purifier:T Echnician Charges Towards Fitting, Fixing, Installation And Commissioning Of Ro Water Purifier 5 Stage Filtration, 50-55 Ltr/Hr. Capacity With Supply Of Clamp, Screw, Nut Bolt And Etc. As Per Requirement And Direction Of Engineer-In-Charge.Make- Lexpure/ Kent/ Livpure , Water Cooler : Supply Of 150 Ltr. Water Dispenser Is A Premium Product Suitable For Residential And Commercial Settings. Its Modern And Elegant Design Makes It A Versatile Addition To Any Space. Equipped With A 1/2 Bsp Thread Connection Type, This Dispenser Guarantees A Secure And Leak-Proof Installation. Boasting A Cooling Capacity Of 150 L/Hr, It Ensures A Constant Supply Of Cold Water. Crafted From High-Quality Stainless Steel, The Body Of This Dispenser Is Durable And Long-Lasting, Resistant To Corrosion, Rust, And Stains. Its Hot And Cold Modes Provide The Convenience Of Instant Access To Both Temperatures Of Water. 02 Nos.. Of Taps, 9.5 Rated Current, Stainless Steel Body. Item Depth (Mm)-589, Item Height (Mm)-1235, Item Weight (Kg)-64, Cooling Capacity (L/Hr)-150, Hot/Warm Water Dispensing Capacity-Na, Hot/Warm Water Dispensing Capacity Unit-Na, Cooling Storage Capacity (L)-150,Cooling Storage Capacity Unit-Liters, Normal Storage Capacity-Na, Normal Storage Capacity Unit-Na, Hot/Warm Water Storage Capacity-2, Hot/Warm Water Storage Capacity Unit-L, Package Width (Mm)-911, Package Depth (Mm)-690, Package Height (Mm)-1247, Package Weight (Kg)-74, Product Warranty-1 Year, Power Rating-Cooling (In Watts) 2100 @35C, Minimum Input Voltage Range 220 (Volts), Maximum Input Voltage Range-240 (Volts), Input Voltage Frequency (Hz)-50, Input Plug / Connector Type-3 Pin Plug , 16 Amp, Cord Length (Meters)-1.5, Function Cold | Warm, Refrigerant-R32, Usp Feature 1 Warm And Cold Dispensing Option, Usp Feature 2 Sturdy Compressor And Trouble Free Operation, Usp Feature 3 Eco- Friendly, Usp Feature 4 Silent Operation, Usp Feature 5 Food Grade Ss304 Tank. Make- Blue Star/ Kent/Usha , Water Cooler : Technician Charges Towards Fitting, Fixing, Installation And Commissioning Of 150 Ltr. Water Dispenser With Supply Of All Clamps , Screws, Nut Bolts And Etc. As Per Requirement And Direction Of Engineer-In-Charge. , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Carbon Dioxide (Co2) Type Fire Extinguisher, Isi Mark, Cap-4.5 Kg. Make - Safepro/Fire Shield , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Abc Type Fire Extinguisher, Isi Mark, Cap-6.0 Kg. Make - Safepro/Fire Shield , Fire Extinguisher : Providing ,Fixing , Testing And Commissioning Of Foam Type Fire Extinguisher, Isi Mark, Cap-9 Ltr. Make - Safepro/Fire Shield , Audio Visual Work : Supply Of Chairman Unit Long Unit- Digital With Chairman Button: Frequency Response:200 Hz To 12.5 Khz Headphones Load Impedance: 32 Ohms 1K Ohm Loudspeaker Nominal Output:72 Db special Length Of Microphone From Mounting Surface:480 Mm (18.9 In) Operating Temperature:0 ºc To +35 ºc Plug And Play Functionality For Ensuring Fast Installation And Reconfiguration Times Immunity To Mobile Phone Interference Functions Possible-To-Speak Indication Built-In Loudspeaker With Volume Control Headphones Socket: Built- In 3.5 Mm (0.14 In) Stereo Headphones Built-In Volume Control For Headphones Color-Coded Led Indicator Above Microphone Button For Showing The Following States: Microphone On, Request-To-Speak, And Possible-To-Speak Similar To Make Bosch Model No. Ccsd- Dl+Chairma N Button Complete. , Audio Visual Work : Supply Of Delegate Unit Long Unit- Digital Frequency Response:200 Hz To 12.5 Khz Headphones Load Impedance: 32 Ohms 1K Ohm Loudspeaker Nominal Output:72 Db special Length Of Microphone From Mounting Surface:480 Mm (18.9 In) Operating Temperature:0 ºc To +35 ºc Plug And Play Functionality For Ensuring Fast Installation And Reconfiguration Times Immunity To Mobile Phone Interference Functions: Possible-To-Speak Indication Request-To-Speak Indication Built-In Loudspeaker With Volume Control Headphones Socket: Built- In 3.5 Mm (0.14 In) Stereo Headphones Built-In Volume Control For Headphones Color-Coded Led Indicator Above Microphone Button For Showing The Following States: Microphone On, Request-To-Speak, And Possible- To-Speak Similar To Make Bosch Model No. Ccsd-Dl Complete. , Audio Visual Work : Supply Of Control Unit For The Ccs 1000 Digital Discussion:Built-In Mp3 Recorder With Internal Memory And Usb Recordingbuilt-In Digital Acoustic Feedback Suppression (Dafs) For Ensuring Superior Speech Intelligibility Plug-And-Play Functionality For Quick And Easy Connection Of Up To 80 Discussion Devices Native Support For Automatic Hd Camera Control. A Maximum Of Four Microphones Can Be Selected On The Control Unit. This Can Be Further Extended To 10 Microphones In The Web Browser Four Basic Microphonemanagement Mode Shall Be There: -(I) Open: Microphone Button Control With Request-To-Speak (Auto)(Ii) Override: Microphone Button With Override Of Activated(Iii) Voice: Voice Activated Microphones(Iv) Push-To-Talk (Push And Hold Button To Speak) Functions Plug- And-Play Functionality Web Browser Control Open Microphone Control Built-In Mp3 Recorder Discussion Controlsimilar To Make Bosch Model No. Ccsd-Curd Complete. , Audio Visual Work :Supply Of Extension Cable Assy 10M Similar To Make Bosch Model No. Lbb4116/10 Complete. , Audio Visual Work : Column Loudspeaker 30W, Metal, Sound Pressure Level At Rated Power /-1 W (1 Khz, 1 M)-105 / 92 Dbspl, Effective Frequency Range (-10 Db) 153 Hz‒ 17.7 Khz, Horizontal Opening Angle At 1 Khz / 4 Khz (-6 Db)-198°/ 130°,Vertical Opening Angle At 1 Khz / 4 Khz (-6 Db)-62°/ 18°,Rated Input Voltage 100 V, Rated Impedance, Full Power 333 Ω, Half Power 667 Ω, Quarter Power 1333 Ω. Similar To Make Bosch Model No. La2-Um30-D-In Complete. , Audio Visual Work : Booster Amplifier 240 W With Electrical Power Supply Input Voltage 230Vac ±10% At 50/60Hz Or 24Vdc Inrush Current 9A At 230 Vac, 11A At 24 Vdc Performance Rated Output (Rms) 240W Power Reduction On Backup Power -1 Db Frequency Response 60 Hz To 18 Khz (+1 / -3 Db At -10 Db Ref. Rated Output) Distortion 1% At Rated Power,1Khz S/N (Flat At Max Volume) 85 Db Power Consumption Max Power Consumption 760 Va Mains Operation Max Power 451W -3 Db 340W Pilot Tone 55W Idle 16W 24V Dc Operation Max Power 12.1A (290W) -3 Db 11.4A (274W) Pilot Tone 1.7A (41W) Idle 0.3A (7W) Line Input S 2X Connector 3-Pin Xlr, Balanced Sensitivity 1 V Impedance 20K Ohm Cmrr 25 Db (50 Hz To 20 Khz) Gain 40 Db 100 V. Similar To Make Bosch Model No. Lbd1935/00 Complete. , Audio Visual Work : 12-Channel Mixing Console: Max. 6 Mic / 12 Line Inputs (4 Mono +4 Stereo) / 2 Group Buses + 1 Stereo Bus / 2 Aux (Incl. Fx).Similar To Make Yamaha Model No. Mg12xu Complete. , Audio Visual Work : Wireless Handheld Microphone System With Frequency Response 50 To 20,000 Hz, Polar Pattern Unidirectional (Cardioid),Output Impedance @ 1 Khz, Typical-600 Ω,Audio Output Level -43.5 Dbv/Pa, Signal-To-Noise Ratio[1]@ 1 Khz-72 Db, Maximum Spl[1]-1000 Ω Load, @ 3% Thd-139.0 Db, Dynamic Range*1+@ 1 Khz, 1000 Ω Load-117.0 Db, L Equivalent Output Noise[1],Typical, A- Weighted-22 Db, Power Requirements +5V Dc (Nominal), 10 V Maximum. Similar To Make Shure Model No. Svx24/Pg28 Complete. , Audio Visual Work : Wireless Lapel Microphone With Frequency Response 50 To 20,000 Hz, Polar Pattern Unidirectional (Cardioid),Output Impedance@ 1 Khz, Typical-600 Ω, Audio Output Level -43.5 Dbv/Pa, Signal-To- Noise Ratio[1]@ 1 Khz-72 D, Up To 8 Selectable Channels, Up To 4 Compatible Systems, Antenna Switching Diversity, Adjustable Squelch Level, Mic / Line Switch. Similar To Make Shure Model No. Svx14/Cvl Complete. , Audio Visual Work : Hydraulic Pop-Up Box Having Multi-Connectors For Data And Power Connection, Hdmi. Connectors: 2X Power, 1X Rj45 Hdmi, 1X Vga, 1X 3.5Mm Audio Jack 1X Video, Hydraulic (Pneumatic) Open Close Movement , With Bottom Box. Similar To Make maintenance Complete. , Audio Visual Work : Interactive Display Panel:Screen Size-86, Panel Technology-Ips, Back Light Type- Direct, Aspect Ratio- 16:9, Native Resolution-3840X2160 (Uhd), Refresh Rate-60Hz, Brightness-440 Nits, Contrast Ratio- 1,200:1, Dynamic Cr- 5000:1, Color Gamut- Ntsc 72%, Viewing Angle(H X V)- 178 X178, Color Depth- 10Bit, 1.07Billion Colors, Response Time-8Ms (Gto G), Operation Hours (Hours/Day)- 16/7, Surface Treatment (Haze)-28%. Connectivity (Jack Interface):Input- Digital-Hdmi- Es(3), Hdcp2.2, Analog-Rgb, Vga(1), Audio- In, Rs232c In, Rj45(Lan), Usb3.0 Type A(4) , Usb2.0 Type A(1), Usb Type C (1), Audio Out, Touch Usb.Mechanical Specification:Bezel Color-Black, Bezel Width-15/15/15/44Mm, Weight(Head)- 58.6 Kg, Packed Weight- 75.9 Kg, Monitor Dimension(W X H X D)- 60 X 100Mm, Carton Dimensions(W X H X D) (Box Outer Size)- 2110 X 1283X225mm, Handle, Vesatm Standard Mount Interface-800X600. Key Feature:Hw-Wi-Fi, Build-In-Slot Type, Power Indicator, Auto Brightness Sensor, Sw- Webosver, Android- 11.0, Screen Share.Environment Conditions:Operation Temperature-0 °C To 40 °C, Operation Humidity-10% To 90%, Power Supply-Ac 100-240V~, 50/60Hz, Power Type-Built - In Power, Power Consumption- Typ.-385W, Max- 580W,Poweroff- 0.5W, Sound-Speaker-Inbuilt (15Wx2), Certification-Safety-Cb / Nrtl , Emc-Fcc Class A / Ce /Kc, Erp , Ops Type Power Built In Compatible,.Accessory:Power Cord 3 M*1, Usb Cable (Type A-Type B) 5 M*1, Hdmi Cable 3 M*1, Writing Pen*2Pcs, User Manual, Qsg, Carton Box, Remote Controller(Include Battery 2Ea), Wifi Module. Reponse Time-≤5Ms, Accuracy-±1Mm, Interface-Usb2.0, Protection Glass Thickness-3T (Anti-Glare), Operating System Support- Windows 7/8/10/Windows Xp/Linux/Mac/Android (Windowsxp/Linux/Mac Support One Point Touch), Multi Touch Point -Max 40 Points. Android System-Soc-Quad Core A55, Gpu-Mali G52mp2, Ram-4 Gb, Wifi-802.11 A/B/G/N/Ac/Ax (Wifi 6), Lan-Gigabit Lan, Bluetooth-Bluetooth 5.0.Make- Lg/ Samsung/ Panasonic , Audio Visual Work : Led Display Tv:Size-65 Inch, Resolution-3840 X 2160 (Uhd), Backlight Unit Type- Direct, Brightness-400Nit, Dynamic Contrast Ratio (Dynamic Mci (Hz))-1,000,000:1, Static (Panel) Contrast Ratio-1200:1, Refresh Rate-60Hz, Video: Hdr (10 Pro / Hlg)-Yes / Yes, Audio: Speaker (Sound Output)-10W + 10W, Broadcasting System: Digital Terrestrial, Cable, Satellite)-Dvb-T2/C, Hospitality Feature-Hotel Mode / Pdm / Installer Menu,0Ne Channel Map, Ip Channel Manager; External Speaker 0Ut (Int Variable/Fixed, 3.5Mm, Stereo, Single Dedtype (Gnd,L+,R+), 2W+2W With 80), Smart Feature- Web 0S Version (Web0s 6.0), Smart Home (Launcher Bar), Web Browser Pre-Loaded App (Youtube Only, ), Sdp Server Compatibility, Mood Display, Soft Ap, Wifi (Version) (802. 11Ac), Screen Share (Miracast), Smart Share, Bluetooth Audio Playback, Hdmi-Arc (Arc, Hdmi2), Signage Feature- Vertical Setup, Fail 0Ver, Play Via Url, Ntp Server Setting, Cisc0 Certi. Compatibility , Crestron Connected (Network Based Control), Dpm (Digital Power Management), Time Scheduler, Rtc (Real Time Clock), Ntp Sync Timer, Beac0n, Embedded Cm (Contents Manager), Embedded Gm (Group Manager), Supersign Sw C0mpability-Control / Control Plus, Cms(Premium), Simple Editor, Input Interface: Setside - Hdmi In (3 (2.0)), Headphone 0Ut (Phone Jack Type), Rs-232C(D-Sub 9Pin / Phone Jack) (Phone Jack, 4Pi), Jack Interface:Set Rear- Usb (2.0), Rf In, Digital Audio 0Ut (0Ptical), Externalspeaker 0Ut(3.5Mm Phone Jack), Rj45 (Usage Purpose) (Lan),Dimensi0n (Unit: Mm Kg): Vesa Compatible-300X300, Weightwithout Stand-21.5, Weight With Stand-21.8, Weight In Shipping-27.8, Size Without Stand-1454X838x57.7, Size With Stand- 1454 X 899 X 271, Size In Shipping- 1600X970x172, Bezel Width(L/R/U/B): 0N Bezel- 12.8/12.8/12.8/19.9, Power Supply (Voltage, Hz)-Ac 120 V-, 50 / 60 Hz, Power Consumption(Max)-198, Power Consumption(Typ)-169, Standby Power Consumption-Under 0.5W, Safety-Cb, Cu Tr, Emc-Ce, Remote Type-S-Con, Power Cable- Detached (1.5M, Straight Type), Onsite-3 Years.Make- Lg/ Samsung/ Panasonic , Audio Visual Work : Supply, Fitting, Fixing And Installation Of All In One Computer Desktop: Specification: Monitor - 24 Inches, Storage - 1 Tb Ssd, Memory - 16 Gb Ddr5, Processor - Intel Core I5, 14Th Generation, Windows Home, Wifi Inbuilt, Warranty-3Years, Make- Dell/ Hp/ Asus/Lenovo , Audio Visual Work : 4X4 4K Hdmi Matrix Switch Connects Any Of 4 Hdmi Sources To Any Of 4 Hdmi Displays, Supports 4K Resolutions Up To Uhd (3840 X 2160) And Dci (4096 X 2160) With Refresh Rates Of 30 Hz (4:4:4) And 60 Hz (4:2:0), Signaling Rates Up To 3.4 Gbits For Flawless 4K Output, Multiple Control Methods - System Management Via Front- Panel Pushbuttons, Ir Remote And Rs-232 Control. Similar To Make Aten Model No.Vm0404h Complete. , Audio Visual Work : Full Hd Ptz Ip Camera For Video Conferencing Which Supports1080p At 60Fps And Versatile 20X Optical Zoom, Delivers Hd Videooutput Via Ethernet, Hdmi, Usb And 3G-Sdi Simultaneously, Sensor, 1/2.8 2.16 Mp Cmos, Video Format-1080P : 60 / 50 / 30 / 25,720P : 60 / 50 / 30,Video Output (Hd) Interface,3G-Sdi / Hdmi / Ethernet / Usb3.0Optical Zoom,20X,Digital Zoom-12X,Horizontal Viewing Angle-57°,Vertical Viewing Angle-32.1°,Diagonal Viewing Angle-,65.4°, Aperture- F1.6~F3.8, Focal Length 5.33Mm~110Mm,Shutter Speed-1/1 ~ 1/10,000 Sec, Minimum Object Distance, Wide: 0.5M / Tele: 1.5M,Video S / N Ratio 50Db,Minimum Illumination-1.0 Lux (F1.6,50Ire, 30Fps), Focus System-Auto / Manual / Smart Af, Gain Control-Auto / Manual, White Balance-Auto / Manual, Exposure Control-Auto / Manual,Wdr,3D Nr Panning Angle+170° ~ - 170°,Panning Speed-225°/Sec, Tilting Angle+90° ~ -30°,Tilting Speed-225°/Sec. Similar To Make Lumens Model No.Vc-A53complete. , Audio Visual Work : Supply Of Usb &Hdmi Cable For Connectivity. Similar To Make Impression Complete. , Audio Visual Work : Supply Of 15U Rack For Controller & Amplifier. Similar To Make Netrack Complete. , Audio Visual Work : Supply Of 2 Core 1.5 Sq.Mm Flexible Speaker Cable As Per Site With Pvc Pipe. Similar To Make Krystal Complete. , Audio Visual Work : Installation, Testing & Commissioning With Transportation Loading Unloading Labour Charges Of The Entire System As Per Scope Of Work And Direction Of Engineer-In-Charge. , Inverter Air Conditioners Supply, Fitting, Fixing, Installation And Commissioning Of Split Ac Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Refrigerant Gas, Drain Pump, Etc As Per The Specifications Of The Following Capacities. Inverter 5 Star Rating. Make - Lloyd/ Lg/ Samsung 2.0 Tr 5 Star Inverter Model Split Ac: Specification:Compressor Type-Duo Rotary, Refrigerant-R-32, Power Supply: V-Hz-Ph-230 V~50 Hz 1 Phase, Operating Voltage Range:V-100 V - 300 V, Input Current (100%/50%):A-7.16 A / 4.13 A, Cooling Capacity (100%/50%):W-6340 W / 3170 W, Input Power (100%/50%):W-1630 W / 570 W, Iseer_5.06, Air Flow:M3/H-1270 M3/H, Air Throw Distance:M-12M, Electricity Consumption:Kwh-970.29 Kwh, Idu Noise:Db-43 Db, Odu Noise:Db-57 Db, Area Coverage: Sq. Metre-19.7 M2, Operating Range-Cools At 52 °C. 5 In 1 Convertible (40 / 60 / 80 / 100 / Auto), Smart 4-Way Swing, Turbo Cool, Rapid Cooling (18°C In 45 S), Installation Check, Low Gas Detection, Clean Filter Indication, Wifi Ready (Optional Wifi),Anti-Viral Dust Filter, Pm 2.5 Filter, Golden Fin Evaporator, Hidden Led Display, Stabilizer Free Operation, Strong Dehumidifier, Blow Function, 100% Copper, Eco Friendly Refrigerant(Ü),Idu Dimensions (Lxbxh) As Per Installed Unit:Cm-(116.1 X 24.0 X 34.0) Cm, Idu Dimensions (Lxbxh) As Per Sowm Label:Cm-(116.1 X 34.0 X 24.0) Cm, Idu Packing (Lxbxh):Cm-(127.0 X 41.5 X 33.5) Cm, Idu Net / Gross Weight:Kg-14.2 Kg / 18.0 Kg, Odu Dimensions (Lxbxh):Cm-(94.0 X 37.0 X 68.0) Cm, Odu Packing (Lxbxh):Cm-(102.0 X 45.5 X 74.0) Cm, Odu Net / Gross Weight:Kg-34.6 Kg / 40.4 Kg , Inverter Air Conditioners Supply, Fitting, Fixing, Installation And Commissioning Of Split Ac Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Refrigerant Gas, Drain Pump, Etc As Per The Specifications Of The Following Capacities. Inverter 5 Star Rating. Make - Lloyd/ Lg/ Samsung 1.0 Tr 5 Star Inverter Model Split Ac: Specification:Compressor Type-Single Rotary, Refrigerant-R-32,Power Supply: V-Hz-Ph-230 V~50 Hz 1 Phase, Operating Voltage Range:V-100 V - 300 V, Input Current (100%/50%):A-3.65 A /1.99 A, Cooling Capacity (100%/50%):W-3500 W / 1750 W, Input Power (100%/50%):W-830 W / 320 W, Iseer-5.2, Air Flow:M3/H-750 M3/H, Air Throw Distance:M-7M, Electricity Consumption:Kwh-520.93 Kwh, Idu Noise:Db-35 Db, Odu Noise:Db-50 Db, Area Coverage: Sq. Metre-11.0 M2, Operating Range-Cools At 52 °C, 5 In 1 Convertible (40 / 60 / 80 / 100 / Auto), Smart 4-Way Swing, Turbo Cool, Rapid Cooling (18°C In 45 S), Installation Check, Low Gas Detection, Clean Filter Indication, Wifi Ready (Optional Wifi),Anti-Viral Dust Filter, Pm 2.5 Filter, Golden Fin Evaporator, Hidden Led Display, Stabilizer Free Operation, Strong Dehumidifier, Blow Function, 100% Copper, Eco Friendly Refrigerant(Ü),Idu Dimensions (Lxbxh) As Per Installed Unit:Cm-(85.6 X 21.9 X 28.5) Cm, Idu Dimensions (Lxbxh) As Per Sowm Label:Cm-(85.6 X 28.5 X 21.9) Cm, Idu Packing (Lxbxh):Cm-(93.4 X 35.5 X 31.1) Cm, Idu Net / Gross Weight:Kg-9.0 Kg / 11.3 Kg, Odu Dimensions (Lxbxh):Cm-(87.0 X 36.5 X 56.0) Cm, Odu Packing (Lxbxh):Cm-(91.0 X 41.5 X 59.0) Cm, Odu Net / Gross Weight:Kg-24.9 Kg / 29.0 Kg. , Installation Of Split Unit : Installation & Commissioning Of Split Air Conditioners Including Inverter Compressor, Condenser, Supports, With Cordless Remote Controller, Etc. , Installation Of Split Unit : Supply, Installation, Commissioning Of Soft Copper Piping (1/4, 1/2 Inch) For Split Units , Clamping, Fittings, Etc. Both The Pipelines Shall Be Insulated With Nitrile Tubular Insulation. , Installation Of Split Unit : Supply, Installation, Commissioning Of 4C X 1.5 Sq. Mm Control Wiring Indoor To Outdoor Unit , Installation Of Split Unit : Supply, Installation, Commissioning Of Pvc Pipes Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit : Supply, Installation, Commissioning Of Pvc Drain Pipes With Supports As Per Drawings And Specifications Of 25Mm Inner Dia Sizes. Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit :Supply, Installation, Commissioning Of Insulation Drain Pipes Including All Cost Of Labour, Material, Conveyance, Etc. Complete And As Per The Directions Of Engineer-In-Charge. , Installation Of Split Unit : Supply, Installation, Commissioning Of Rapping Tape , Installation Of Split Unit : Supply, Installation, Commissioning Of Odu Bracket. , Installation Of Split Unit : Supply, Fitting, Fixing, Installation, & Commissioning Of Outdoor 30 Kva (280V-470V) Un-Balanced Load Three Phase, Air Cooled Servo. Specification: Standard-Iso 9001-2008 Standards, Type-Un-Balanced Type Three Phase Air Cooled, Rating-30 Kva, Input Voltage Range-280V - 470 V, Output Voltage Range-400 Volts±1%, Input Frequency-45-55 Hz, Response Time-10M Sec, Correction Speed-35 To 45 Volt Per Sec, Efficiency-Better Than 98%, Metering / Control-Digital Ac Voltmeter With Output Measure Switch, Ampere Meter For Three Phases, Core Used-Mitor Grade Core For Buck / Boost Transformer, Winding-Electrolytic Copper Grade ( F Class Insulated), Temp. Rise-35˚ C Deg. Cent. Above Ambient, Winding Temp.-Rise 40˚ C Deg., Application-Indoor/Outdoor Type, Transformer Oil-Is 335 Making (Power Oil), Output Accuracy-+/- 1 % From No Load To Full Load, Wave Form Distortion Virtually Nil, Losses At No Load-0.12% Of The Total Capacity, Losses At Full Load-0.7% At Full Load, Terminations-Suitable Bus Bars Will Be Provided In The Termination Box, Operating Temp-0 To 55 Degree Centigrade Along With 2 Nos.. Of Earthing Terminal At Both Side Of Unit And Fabricated Outdoor Stand. Make- Jyoti/V-Guard/Microtek , Installation Of Split Unit : Supply And Laying Of 10Sqrmm Single Core Copper Flexible Wire Along With Proper Safety And Clamping Arrangement. Make- Havells/ Polycab/ Kei , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Supply Of Premix Tea/Coffee Vending Machine: (Multi Option- 3 Nos.. Beverages):Technical Specifications:Supply, Fitting, Fixing, Installation And Commissioning Of Premix Tea/Coffee Vending Machine Of 3 Lane, Net Weight-18.2 Kg, Gross Weight-21.2 Kg, Dimensions (W X D X H)-340 X 485 X 625 Mm, Package Dimensions (W X D X H)-390 X 535 X 695 Mm, 3 Drinks, Gi Body Material, Front Door-Abs Moulded, Power Source-220/110V-1P, Power-1500 Watt., Start-Up Time- Up To 10 Minutes, Dispensing Rate- Up To 22 Cups In One Time Of 100 Ml, Premix Canister-3 Nos.., Water Input-Bubble Top/Pump (Optional), Hot Tank Material-Ss 304, Canister Capacity-1.1 Kg., Auto Flush-Available, Dedicated Hot Water-Yes, - Sensor Operating Range (Only For Touch Less Model Ne/Ap)- 25 Mm (1 Inch).Make - Nescafe/ Godrej/ Nestle , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Installation Charges Of Coffee Vending Machine As Per Direction Of Engineer-In-Charge. , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Ingredients: Bru Coffee Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Ingredients: Nescafe Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Premium Teabags (200S) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Sugar Sachet (1Kg) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Lemon Tea Premix , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items Disposable Nescafe Paper Cup 110Ml(50Nos.) , Installation Of Coffee Machine, Delegate Chairs, Induction Cook Stove, Refrigerator, Crockery Items 3 Supply, Fitting, Fixing And Installation Of Mini Fridge : Specification: 92L Fridge Single Star Energy Rating, Direct Cool Technology And Single-Door Design With A Capacity Of 92 Liters. Its Dimensions Are 45.5 Cm X 49.5 Cm X 84.5 Cm (W X D X H) With A Net Weight Of About 21 Kg, And It Uses R600a Refrigerant With A Fixed-Speed Compressor. It Features Toughened Glass Shelves And An Internal Manual Control Panel. , Chairs: Supply, Fitting, Fixing Of High Back Revolving Chair, Overall Dimension:- 720W ±10 X 720D ±10 X 1290H ±10 Mm, Seat& Back Of Chair Is Made Of 12Mm Hot Pressed Plywood And Connected With Ms Powder Coated L Patta Of Size 65X8mm, Seat & Back Cushioned With Pu Foam In D-45 Kg/M3 & Prime Quality Leatherette Upholstery , Seat Size:- Seat Size:- 540W ±10 X 520D ±10 X 60 Thick. ±5 Mm, Back Size:- 530W ±10 X 730H ±10 X 60Thick. ±5Mm,Mechanism: Torsion Bar Single Point Control, Provides Maximum Adjustability And Scope For Comfort, Seat & Back Moves In Same Direction, Single/ Upright Position Locking, Tilt Tension Knob To Loosen Or Tighten The Tension According To Users Body Weight, Gas Lift:- Lift -Used Gas Lift Of 100Mm Size Of Class-Iv Grade , Plastic Gas Lift Cover, Armrest:- Leatherette Upholstered On Foam Cushioned Armrest Fixed Pp Structure And Ss Frame, Armrest Fixed With Seat & Back Which Gives Comfort & Strength Both To The Chair, Chair Base & Wheels: Metal Chrome Plated Chair Base Frame Made Of 2.5Mm Thick, Base Front Edges Are In Nylon, Base Consists Of 5 Prongs With 650±5 Mm Pitch Circle Diameter, 60Mm Dia. Black Nylon - Twin Wheel Pin Castor. Make- Methodex/ Godrej/ Ayesha , Chairs: Supply, Fitting, Fixing Of Medium Back Revolving Chair, Overall Dimension:- 720W ±10 X 720D ±10 X 1160H ±10 Mm, Seat& Back Of Chair Is Made Of 12Mm Hot Pressed Plywood And Connected With Ms Powder Coated L Patta Of Size 65X8mm, Seat & Back Cushioned With Pu Foam In D-45 Kg/M3 & Prime Quality Leatherette Upholstery , Seat Size:- Seat Size:- 520W ±10 X 510D ±10 X 60 Thick. ±5 Mm , Back Size:- 530W ±10 X H 610 ±10 X 60Thick. ±5Mm,Mechanism: Torsion Bar Single Point Control, Provides Maximum Adjustability And Scope For Comfort, Seat & Back Moves In Same Direction, Single/ Upright Position Locking, Tilt Tension Knob To Loosen Or Tighten The Tension According To Users Body Weight, Gas Lift:- Lift -Used Gas Lift Of 100Mm Size Of Class-Iv Grade , Plastic Gas Lift Cover, Armrest:- Leatherette Upholstered On Foam Cushioned Armrest Fixed Pp Structure And Chrome Plated Frame, Armrest Fixed With Seat & Back Which Gives Comfort & Strength Both To The Chair, Chair Base & Wheels: Metal Chrome Plated Chair Base Frame Made Of 2.5Mm Thick, Base Front Edges Are In Nylon, Base Consists Of 5 Prongs With 650±5 Mm Pitch Circle Diameter, 60Mm Dia. Black Nylon - Twin Wheel Pin Castor. Make- Methodex/ Godrej/ Ayesha , Chairs: Supply Of Signature Fabric Arm Chair. Specification: High-Quality Plastic Construction For Lasting Durability. Ergonomic Design With Cushioned Seat And Backrest. The Glossy Lacquered Finish Resists Uv Rays And Rust. Soft-Feel Fabric Adds A Touch Of Comfort And Beauty. Easy To Clean And Maintain, Suitable For Indoor And Outdoor. Dimensions : Width (Cm) 56, Depth (Cm) 58, Height (Cm) 80, Weight (Kg) 5.2. Make- Nilkamal/ Supreme/ Cello , Induction Stove : Supply, Fitting, Fixing Of 2000W Induction Cooktop.Specification:Induction Cooktop, 2000W, 8 Cooking Options, Overheat Protection, Child Lock Function, Auto Pan Detection & Auto Power Off, Digital Display And Led Indication For Easy Operation, Fixed & Variable Cooking Options With 10 Power Settings (120 W To 2000 W), Dedicated + & - Options To Control Power Levels, Temperature As Well As Time. Make- Havells/ Bajaj/ Prestige , Induction Stove : Supply Of Stainless Steel Drinking Water Bottle, 1.0Ltr. Specification: Drift Stainless Steel Bottle 950 Ml, Size & Dimensions In Cms (L X W X H)-7.5 X 7.5 X 27.5, Size & Weight-950 Ml - 392 G, Cap Type - Screw Cap • With Lid - Yes , Care Instructions - Hand Wash Only, Package Contents - 3 X Drift Stainless Steel Bottle. Make-Milton/Cello/Borosil , Induction Stove : Supply Of Ceramic Snacks Plate Of Size 7 Inches/ 17.8 Cm Make-Milton/Cello/Borosil , Induction Stove : Supply Of Cup With Saucer For Tea/Coffee In Ceramic Make-Milton/Cello/Borosil , Induction Stove : Supply Of Transparent Drinking Water Glass Of 300Ml. Make-Milton/Cello/Borosil , Induction Stove : Supply Of Stainless Steel Snacks Spoon Make-Milton/Cello/Borosil , Induction Stove : Supply & Fixing Of Metal Chrome Finish Plain Pedal Stainless Steel 15L Capacity Dustbin With Lid & Pedal Of Free Size Dimension 30X20x20 Cm. , Induction Stove : Supply And Fixing Of Rectangular Shape Non Slip Foot Mat Of Size 4Ft. X 2Ft. , Induction Stove : Supply And Fixing Of Cotton Luxury Office Chair Towel. , Interior Work : Supply And Installation Of 12.5 Mm Thick Gypsum Glass Fiber Reinforced (Gfr) Pixello 8 / 18 With 8 Mm Circular Diameter & 18 Mm Pitch, Total Open Area 15%, Having Broadband Sound Absorption, With Size Of Boards 1200 X 2400 Mm, Having Density 700 Kg / M³ & Weight 9 Kg / M², With Fire Class 1 & P, Climate 0°C, Rh (50-70), Nrc Up To 0.80, To Be Fixed With Philips Head Screw To Suspended Gi Frames As Per The Specification For Fixing Concealed Grid Ceiling System. The Concealed Wall Paneling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 25 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centers. Then Fixed Main Channels (Mc 45) To Be Suspended With The Help Of Gi Channel Sa 25 From Reinforced Cement Concrete / Perling. The Mc 45 Channels Have Thickness 0.9 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Side Wall & Fixed At Every 1200 Mm Centers, With Gi Ceiling Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centers. The Framework Will Maintain 50 / 75 Mm Gap From The Walls. Now Lifting The Boards On The cement concrete 25 With The Help Of Screw To Get A Flush Finish. The Jointing & Finishing Of The Same Will Be Done By Using Jointing Compound, Paper Tape. The Synthetic Polyfiber Pf5 X 25 Wool Of 50 Kg Density & Width 600 Mm, 5000 Gsm To Be Laid On The Top Of The Framework / Boards. Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Fixing Of 1 Mm (10% +/-) Polymer Based Acoustic Louvers Ceiling Systems Of Pare Innovations Of Panel Sizes Of 265 Mm X 3060 Mm, Along With Option To Custom Size To A Maximum Of 12800 Mm In Length In Approved Shade, Manufactured In India, Made With High Temperature Thermal Transfer Technology, Waterproof, Fire Retardant And Antibacterial. Termite Resistant, Rustproof Material. Panels To Be Installed With Gi Sections Of Suitable Gauge & Size, Subject To Change According To Site Conditions. Panels To Be Installed Using Suitable, Same Shade J-Trim With Dimensions 39 X 20 X 3060 Mm (All In Mm) For Edge Profiles And Connector With Dimensions 76 X 20 X 3060 Mm, Using Same Shade For Connecting Panels, Using Outside Corner With Dimensions 61 X 63 X 3060 Mm, Which Can Be Used In +90 Degree Corners, And Inside Corner Having Dimensions 28 X 76 X 3060 Mm, Which Can Be Used For 90 Degree Corners. Panels Are Maintenance Free And Come With 10 Years Warranty For Colour & Finish Of The Panels, Including Trims Of Pare Innovations. All Material, Accessories, Ancillary Components As Per Recommendation Of Pare Innovations. , Interior Work : Supply And Fixing Of 1 Mm (10% +/-) Polymer Based Acoustic Louvers Wall Panelling Systems Of Pare Innovations Of Panel Sizes Of 265 Mm X 3060 Mm, Along With Option To Custom Size To A Maximum Of 12800 Mm In Length In Approved Shade, Manufactured In India, Made With High Temperature Thermal Transfer Technology, Waterproof, Fire Retardant And Antibacterial. Termite Resistant, Rustproof Material. Panels To Be Installed With Gi Sections Of Suitable Gauge & Size, Subject To Change According To Site Conditions. Panels To Be Installed Using Suitable, Same Shade J Trim With Dimensions 39 X 20 X 3060 Mm (All In Mm) For Edge Profiles And Connector With Dimensions 76 X 20 X 3060 Mm, Using Same Shade For Connecting Panels, Using Outside Corner With Dimensions 61 X 63 X 3060 Mm, Which Can Be Used In +90 Degree Corners, And Inside Corner Having Dimensions 28 X 76 X 3060 Mm, Which Can Be Used For 90 Degree Corners. Panels Are Maintenance Free And Come With 10 Years Warranty For Colour & Finish Of The Panels Including Trims Of Pare Innovations. All Material, Accessories, Ancillary Components As Per Recommendation Of Pare Innovations. , Interior Work : Providing, Fitting & Fixing Of Pre-Moulded Decorative Corner Beading Of Grc, Having Cross Sectional Dimension 112 X 80 Mm And Fixing The Same By Providing Pvc Plug, Screw, Cornice Adhesive, Fevicol Etc., Complete In All Respect As Per Direction Of Engineer-In-Charge. , Interior Work : Supply & Installation Of Wall Panelling Of Anutone Lisoslats Variosurco High Density Fiber Board, Made Out Of Pure Pine Wood Particles, Fr Grade Pure Pine Wood Particle Core With Test Bs 476 Part 5, Melamine Laminated Finish, Perforated Wooden Grooved Hdf Slats L16-2 (2 Mm Grooves @ 8 Mm Centres), Tongue & Groove Edge For A Seamless Look Of Linear Dimension Size 128 / 192 Mm X 2440 Mm X 16 Mm Thick, Having Density 700 Kg / M³, Weight 9 Kgs / M², 2 Mm Front Side Sound Absorber & 1076 Dis Tractor Hole, Non-Woven Acoustic To Be Pasted On Slats. Teak Teca / Beech Haya Surco Is To Be Installed By Using Gi Strut System. The Technical Parameters Are As Follows: Core Variants: Fiber Board Climate (Ocrh): 50-70 Light Reflectance: 75% Green (Rc%): 25 Hygiene (Voc, Clean Room): Low Class: 1 Nrc: 0.85 Strength, Load Capacity (Kg): Anti-Sag, Ball Impact The Concealed Wall Panelling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 25 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centres. Then Fixed Main Channels (Mc 45) Having Thickness 0.8 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Side Wall & Fixed At Every 1200 Mm Centres, With Gi Cross Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centres. The Framework Will Maintain 50 / 75 Mm Gap From The Walls. Now Clad The Wooden Anutone Slats Surco On The cement concrete 18 With The Help Of Centre & Edge Clips To Get Better Locking Of Slats. The Tongue & Groove Are To Be Properly Aligned To Get A Flush Look. Synth Anutone Poly Fiber Pf5 X 50 Wool Of 500 Gsm To Be Filled Between The Horizontal & Vertical Studs As Infiller With The Help Of Wire / Stick 7 Adhesive. Make: Anutone / Uno Panel / Techtom , Interior Work : Supply & Installation Of Anutone Pine Wood Wool Magnesia Bonded Soak Fabric Cord Binary / Triangle Design Of Selected Colours (Ref. Colour Chart), Kerf Edge Fabric Wrapped, Pine Wood Fibers Panels Of Size 600 X 600 / 1200 X 25 Mm, Having Density 400 Kg / M³, Weight 10 Kg / M², Installed By Using Gi Strut System. The Gi Strut Work Includes Cross Channels cement concrete 50 Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 50 Mm, Depth 50 Mm & Base 100 Mm, Equal Flanges Of 13 Mm, Which Is Fastened To Wall Positioned Horizontally In A Regular Manner At 600 Mm Centers. Pvc Vinyl Core Uv Treated H Spline Having Thickness 2 Mm & Length 2400 Mm To Be Fixed, Using Z Bar Or H Spline On The Back Or Edge Of Panels / Tiles & Similar On The Back Of Channels Perpendicular To The Cross Channels cement concrete 50 At 600 Mm Centers. Kerfed Edge Fabric Wrapped Factory Panels Shall Then Be Inserted Into The H Spline Against The Wall To Perfect Fit. Panels Shall Be Back Lined With Acoustical Infill Of Anutone Synth Pf5 X 50 Mm Thick, Adhered To The Wall Using Stick 7 Adhesive. The Technical Parameters Are As Follows: Core Variant: Pine Wood Fibers Fire Class: 1 & P Acoustic - Nrc 20 Mm C10: 0.85 Climate: 0°C, Rh 50-90 Termite Resistance: Yes Light Reflectance: Colour Dependent Green Rc%: 10 Hygiene (Voc, Clean Room): Low Strength, Load Capacity (Kg), Ball Impact Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Installation Of 20 Mm Thick Pine Wood Wool Magnesia Bonded Colour Tiles / Panel Having Size 600 X 2400 / 1200 Mm, Having Density 400 Kg / M³ & Weight 8 Kg / M², With Fire Class 1 & P, Climate 0°C, Rh (50, 90), Nrc - 0.97 & Green (Voc, Rc%) Low, 10 To Be Fixed With Philips Head Screw By Using Concealed Ceiling System. The Concealed Ceiling System Shall Include Gi Wall Channel (Wc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Unequal Flanges Of 15 & 20 Mm And Web Of 22 Mm, Which Should Be Fixed Along The Perimeters Of The Wall With Nylon Sleeves And Suitable Fasteners At Every 300 Mm Centers. Then Suspend Main Channels (Mc 45) Having Thickness 0.9 Mm, Length 3600 Mm, Equal Flanges Of 15 Mm And Web 45 Mm From The Soffit At Every 1200 Mm Centers With Suspender Angle (Sa 25) Having Thickness 0.45 Mm, Unequal Flanges Of 25 & 10 Mm. Gi Ceiling Channel (Cc 25) Having Thickness 0.45 Mm, Length 3600 Mm, Knurled Web 35 Mm, Depth Of 25 Mm And Equal Flanges 9.5 Mm, Is Fastened To The Main Channel In The Direction Perpendicular To The Main Channel At Every 600 Mm Centers. Now The Jointing & Finishing Of The Same Will Be Done By Using Sealant To Look Flush. Now, 20 Mm Strand Square Edge Of Size 600 X 2400 X 15 Mm Thick Shall Be Fixed. Apply Synthetic Poly Fiber Pf5 X 10 Acoustic Wool Of 50 Kg Density To Be Kept On The Top Of The Ceiling By Laying On The Framework. Make: Anutone / Uno Panel / Techtom. Test Certificate Of The Used Products Shall Be Submitted After Procurement Of Materials. , Interior Work : Supply And Installation Of Broadloom Carpet In Roll Form Of Approved Make, Shade & Pattern For Conference Hall. Carpet Shall Be Of Loop Pile, Of Size 500 Mm X 500 Mm, Having Pile Yarn Or Equivalent Material, Having Minimum Pile Height Of 2.9 Mm And Maximum Total Height Of 9 Mm With Backing Of 6 Mm Thick Open Cell Pu Foam. Carpets Shall Have Inbuilt Soil Protection, Fire Resistance And Antistatic Properties. Carpets Used Shall Also Be Certified From Leed / Griha, Certified With A Test For Indoor Hygiene Properties. , Interior Work : Supplying And Fixing Murals With Frame Of Natural Fibre/Putty Of Approved Size Including Cost Of All Materials, Labour, T&P Etc Required To Complete The Work As Per Drawing, Design And Direction Of Engineer-In-Charge. , Interior Work : Manufacture, Supply And Installation Of Noise (Stc 45) Fire Rated Acoustical Doors Of Size 1200 X 2100 Mm (Main Auditorium Doors). Framework Consists Of Wooden Sections Of Size 150 Mm X 75 Mm (Nominal Finished Frame Section Of 143 Mm X 65 Mm) With Self-Adhesive Type Perimeter Seals On The Perimeters Of The Frame And The Shutter Edges (Note: Shutter Is Double Edged). Fixing Arrangements Shall Be By Means Of 4 Nos.. Of G.I. Holdfast 225 Mm X 20 Mm X 4 Mm With Split End On Either Side Of The Wall, Including 8 Nos.. Of Stainless Steel Ball Bearing Hinges Of Ss 304 Quality Of Size 102 Mm X 102 Mm X 3 Mm Thick, Capable Of Taking Load Up To 120 Kg Of The Shutter, With Ss Pin, Lock Strike Plate, Shock Absorbers As Specified. 60 Mm Thick Double Leaf Shutter Of Appropriate Size Made Out Of Perimeter Railing Of Seasoned Red Marenti Hardwood (Moisture Content Limited To 18%) Of Size 100 Mm X 30 Mm And 2 Nos.. Of 6 Mm Thick Promina-60 Board, Lined With Sound Deadener (Sound Deadening Membrane 4 Mm Thick) Sandwiched Between 2 Boards On Each Side Of The Shutter Framework Using Suitable Fasteners And Duly Hot Pressed With 3 Mm Commercial / Marine Ply To Get The Required Surface For Laminate / Veneer / Paints. Cavity Is Filled With 96 Density X 50 Mm Thick Rock Wool. Doors Shall Be Provided With Acoustical Perimeter, Centre & Drop Down Seals. Make: Stairwell Studio, Tesco, Signum Doors. , Interior Work : Supplying, Fitting And Fixing In Position 32 Mm Thick Flush Door With Teak Wood Beading And 1 Mm Thick Sunmica To Both Sides Pasted With Adhesive, Including Fixing Of Fixtures Like Godrej Make Mortice Lock Having Model No. 9168, Godrej Make Door Closer Having Model No. 8340, 100 Mm Aluminium Hinges, Handle, Tower Bolt, Stopper, Including Cost Of All Materials, Labour, All Taxes, Transportation, Loading & Unloading Etc., Complete As Per Specification And Direction Of The Engineer-In-Charge. , Interior Work : Providing And Putting In Position Column / Wall Panelling As Per Approved Drawing, Made Out Of 12 Mm Thick Bwr Ply Over Framing With 1 Mm Thick Approved Colour Laminate, Including Cost Of All Materials, Labour, T & P Etc. Required For The Work, Complete In All Respect As Per The Direction Of The Engineer-In-Charge. , Interior Work : Providing And Fixing Wooden Venetian Blinds With Pelmet Of Vista Brand As Per The Approved Shade And Design, Along With All The Accessories Including Cost, Conveyance, Loading, Unloading, Taxes Of All Materials, Cost Of All Labour, Sundries And T & P Etc. Required For The Work, Complete As Per Specification And Direction Of The Engineer-In-Charge. , Interior Work : Supplying And Fixing Of Conference Table Of Size 40-0 X 8-0 X 2-6 (Veneer Finish), Made Out Of Calibrated Bwp Plywood With Approved Shade Of 1 Mm Thick Flitches Veneer. It Should Be Provided With Leg Structure Made Out Of 25 Mm Thick Ply & 32 Mm Ply Finished With Veneer For The Top. It Should Have Provision For Necessary Power (Pop-Up Box). All Exposed Edges Should Be Mechanically Edge Banded By Matching 1 Mm Thick Veneer Edge Banding With Hot Melt Glue (Jowat / Henkel). All Pressing Veneer Onto The Ply Has To Be Executed Mechanically By Hot Press And Polymerised D3 Adhesive (Kleiberit / Jowat / Henkel). The Non-Exposed Area Will Be Covered Up By 0.8 Mm Balancer Laminate. The Same Furniture Will Be Finished With Two Coats Of Sealer Followed By One Top Coat In Pu. The Pu Lacquer To Be From Sirca / Teknovance (Italy). It Should Have A Knock Down Arrangement Of Fitting. All Hardware Fittings Will Be Hettich / Hafele / Blum Make. Make By Vibe. , Interior Work : Supplying And Fixing Of Stage Table Of Size 12-0 X 2-0 X 2-6, Top Made Out Of 25 Mm Calibrated Bwp Plywood With Approved Shade Of 1 Mm Thick Flitches Veneer, Having Side Panel Continuing Up To The Floor Connected By A 16 Mm Modesty Panel. It Should Be Provided With Leg Structure Made Out Of 25 Mm Thick Ply & 32 Mm Ply Finished With Veneer For The Top. All Exposed Edges Should Be Mechanically Edge Banded By Matching 1 Mm Thick Veneer Edge Banding With Hot Melt Glue (Jowat / Henkel). All Pressing Veneer Onto The Ply Has To Be Executed Mechanically By Hot Press And Polymerised D3 Adhesive (Kleiberit / Jowat / Henkel). The Non-Exposed Area Will Be Covered Up By 0.8 Mm Balancer Laminate. The Same Furniture Will Be Finished With Two Coats Of Sealer Followed By One Top Coat In Pu. The Pu Lacquer To Be From Sirca / Teknovance (Italy). It Should Have A Knock Down Arrangement Of Fitting. All Hardware Fittings Will Be Hettich / Hafele / Blum. Make By Vibe By Transform Furnitures Pvt. , Interior Work : Providing And Fixing Wooden Podium Of Size 19-0X10-0X0-6Including Cost Of All Materials, Labours, T&P Etc Complete As Per Direction Of Engineer-In-Charge. , Interior Work : Supplying All Materials, Labour, T & P And Providing And Fixing In Position M.S. Panelled Door (Double). Supplying & Fixing Of Pantry Unit Made Out Of 16 Mm Calibrated Bwp Plywood With Approved Shade Of Laminate, With Exposed Side & Inside 0.8 Mm Balancer Laminate. All Laminates Have To Be Hot Pressed With D3 Glue (Jowat / Henkel / Kleiberit Glue). The Said Storage Should Have Two Side Panels & A Bottom Panel. The Top Will Be Moulded Granite Top. It Should Be Provided With A Back Panel Made Out Of 6 Mm Thickness. The Cabinet Should Be Provided With Two Openable Shutters Mounted With The Cabinet By Full Overlay Hinges. The Shutter Has To Be Laminated With 1 Mm Thick Lamination Hot Pressed Onto It. All Exposed Edges Should Be Mechanically Edge Banded With Pvc Edge Banded Tape (Rehau / Dolkan) Using Hot Melt Glue. It Should Have A Knock Down Arrangement Of Fitting. All Boring Has To Be Done On Cnc For Precision Of Fitting. The Hardware Will Be Of Hettich / Olive Make. The Carcass Will Be Provided With Suede Finished Edge Banded Shutters. All Accessories Are In Ss, Make By Vibe By Transform Furnitures Pvt. Ltd. , Interior Work : Providing And Painting Two Coats With Plastic Emulsion Paint Over A Coat Of Primer Of Approved Quality And Approved Shade In All Floors At All Height By Making The Surface To The Interior Plastered Surface Of Walls Smooth, Including Cost, Conveyance, Loading And Unloading And Taxes Of All Materials, Cost Of All Labour, Sundries, T & P, Scaffolding Etc. Required For The Work And Complete In All Respect As Directed By The Engineer In Charge. , Interior Work : Providing And Fixing Glass Reinforced Concrete (G.R.C) Screens In Approved Size, Pattern, Design, Shade And Thickness Of 50 Mm On Frame And Design Element In 30 Mm Thick, Having Weight Approximately Between 3.5-4 Kg Per Sq. Ft. The Above Weight And Thickness Is Considering Dimensions Of Screens Up To 2133 Mm In Height And 1219 Mm In Width And Having At Least 50% Void Space. The Screens Should Be Made From ‘53 Grade White Portland Cement Manufactured By ‘Jk Cement Or Equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber Manufactured By ‘N.E.G Japan Or Equivalent, Super Plasticizers Manufactured By ‘Basf Or Equivalent, Polymers Manufactured By ‘Basf Or Equivalent, And U.V Resistant Synthetic Inorganic Pigments Should Be Used For Pigmentation Manufactured By ‘Bayferrox (Germany) Or Equivalent. The Material Castings Should Take Place In Frp Molds. The Fixing Of Screens Should Be ‘Dry Fixing, I.E., To Be Done With M.S. Galvanized Clamps, Fixtures And Fasteners Of The Shutter Frame. , Interior Work : Signage With Letter Writing Of Brass Finish Of Approved Size As Per Direction Of Engineer In Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
22.
Defence #9857154 Technical Bid
Tender For Provision Of Or Md Accommodation At Clement Town Dehradun.; 2 Construction ofORs Md Accn (G+6 storey),(RCC Framed Structure) ,including RCC over head tank of capacity 25KLoverterrace, with permanent specification all as shown on drawings and as specified. 3 SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder 4 SCHEDULE A PART II-B (Internal Water Supply) 5 S&F Brass Chromium Plated Wall Mixerfor mixing hot and cold waterwith L bend including shower of size 125 mm and shower arm , screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 6 S&F Brass Chromium Plated Central hole wash basin Mixer fancy type with or without lettered Hot or Cold with long screwed shanks and fly nut capstan head screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 7 S&F Brass Chromium Plated Angle Valve, fancy typescrewed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 8 S&F Health faucet with hose & hook ( complete set) fixed to angle / stop cock 15 mm dia complete all specified and directed. 9 S&F 15 mm bore CP pillar tap fancy type screwed down for iron pipe complete all specified and directed. 10 S&F 15 mm bore brass chromium platedsink mixer fancy type with swinging spout (wall mounted type) for mixing hot and cold water screwed downfor iron pipe complete all as specifed and directed 11 SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder 12 SCHEDULE A PART III-B (Internal Electrification) 13 M & L forpoint wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, IS-694 single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e, modularswitch / socketsincl cover plate with frameincluding one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly inclcutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: - 14 Note: (i) Also includes inverter wiringwith one run of inverter wire 1.5 sqmm all alongwith circuit also included. (ii) All items used should be ISI marked. (iii) Cutting chases for concealed type point wiring including making good the same with plaster/putty is deemed to be included in quoted rate by the contractor. (iv) Accessories modular metal boxes, cover plate inner & outer is also deemed to be included in quoted rate. 15 (a) One light point/ bulb/ security light /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way switch. 16 (b) One three pin 5 Amp socket on same board with other switches. 17 (c) One three pin 5 Amp socket on independent board 18 (d) All as per item No 5.01 above but for two way wiring 19 (e) All as per item No 5.01 above but point wiring with cable 2.50 Sq mm size, with earth continuity conductor of size 2.50 Sq mm. 20 All as per item No- 5.01 above but point wiring with cable 4.0 Sq mm size, with earth continuity conductor of size 4.0 Sq mm. 21 Supply & fixing decorative wall mounted LED tube light 1 x 20 watt with polycarbonate housing and integrated electronic driver with all acessories and fixing materialcomplete all as specified and directed. 22 Supply & fix decorativeLED tube light 1 x 10 watt wall mounted with extruded polycarbonate, integrated lamp & driver with opel diffuser and decorative end plates complete with all acessories and fixing materialcomplete all as specified and directed. 23 Supply & fix LED lamp 9 watt with suitable for batten / angular holder complete all as specified and directed. 24 Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 08 way, with 200Amps rated copper bus bar and IP - 54 & IK 09 protection, with the inbuilt provison forfixing of 1 No MCCB 160 Amps Capacity and 24 Nos MCBs inside of DB, with metal door and flush to wall including grouting and cutting in existingwall and making good disturbed surfacewith two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed. Note : MCCB and MCBs shall be provided inside the verticle DBs alongwith suitable size of copper wiring. 25 Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep,min air delivery 210 CFMfive star rated with BLDC motor, super energy efficient, including provision of flexible cable 3 core of suitable size from ceiling rose to fancomplete all as specified and directed. 26 Supply and fixinglight duty Exhaust fan 300 mm sweep metal body with sturdy steel bird cage,double ball bearing and heavy duty motor copper winding, metal blades and fixing accessories 230 Volt, 28 Watt and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. 27 Supply and fixing light duty Exhaust fan 230 mm sweepmade of sturdy engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, Rpm 1200, copper windingand fixing accessories 230 Volt and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. 28 SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder 29 SCHEDULE A PART V (Road, Path and Hardatanding) for details refer pdf folder 30 SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder 31 SCHEDULE A PART VI B (Sewage Disposal) 32 M & L for construction of septic tank 100 users withclass B brick masonry wall, PCC in foundation floor, M 30 Design Mix RCC over slab including sludge chamber, CI vent pipe, CI cowl, inlet and out let pipe, RCC baffle wall and all necessary excavation and earth work complete all as specified , shown in TD drawing No 217 sheet No 1/7 to 7/7as directed. 33 M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80 M dia X 3.00 M effective depthall as specified and shown in drawing TD-309, sheet No 1/4 to 4/4 34 SCHEDULE A PART VII (Area Drainage) for details refer pdf folder 35 SCHEDULE A PART VIII (Fencing / Gate/ Compound wall) for details refer pdf folder 36 SCHEDULE A PART IX A(Rain Water Harvesting) for details refer pdf folder 37 SCHEDULE A PART IX B (Rain Water Harvesting) 38 Supply andfilling of sand of size 1.50 mm to 2.00 mm in rain water harvesting pit complete all as specified & directed. 39 Supply andfilling of pea gravel of size 5.0 mm to 10.0 mm in rain water harvesting pit complete all as specified & directed. 40 Supply andfilling of stone grit of size 40.0 mm in rain water harvesting pit complete all as specified & directed. 41 Supply andfilling of brick ballast (half burnt ) in rain water harvesting pit complete all as specified & directed. 42 Boring for rain water harvesting 150 mm diameter boring from level to first water tablecomplete all as specified & directed. 43 SCHEDULE A PART X A (External Water Supply) for details refer pdf folder 44 SCHEDULE A PART X B (External Water Supply) 45 M&Lfor Ductile iron pipe, centrifugally cast spun with socket and spigot ends, class K7 suitable for push on joint (rubber gasket D-jointing), 100mm dia, conforming to IS-8329 (2000), in standard length with cement mortar lining inside the pipe without side zinc coating, laid in trenches complete all as specified and as directed. 46 M&L for road cutting 0.75m width and 1.2m depth for laying and dismantling of DI/GI pipes and making good the disturbed surfaces including returning fillingwith and including and PCC (1:3:6) upto depth 20cm from road surface and removing of soil upto 50m complete all as specified and directed . 47 M&L for construction of masonry Pit of size 750 mm x 750 mm x 750 mm for valves and meterscomplete with MS sheetcover and locking arrangement including brick work using sub classB bricks and 15mm thick rendering in cement mortar 1:4 (internal / external) including two coats of white washing to exposed surfaces including2 coats painting to MS sheet cover with synthetic enamelledpaint over a coat of red oxide primer including necessary earthwork in any type of soil and PCC 1:4:8 type D2 as in foundation all as specified and directed. 48 M&L for construction of masonry Pit of size 900 mm x 900 mm x 900 mm for valves and meterscomplete with MS sheetcover and locking arrangement including brick work using sub classB bricks and 15mm thick rendering in cement mortar 1:4 (internal / external) including two coats of white washing to exposed surfaces including2 coats painting to MS sheet cover with synthetic enamelledpaint over a coat of red oxide primer including necessary earthwork in any type of soil and PCC 1:4:8 type D2 as in foundation all as specified and directed. 49 Supply and fixing Air realese valve cast iron,double rubber ball type,body fabricated with cast iron,including high & low pressure cover,cowl as per IS 210 FG 200 conforming to ISI marked, including bolts, nuts, washer and rubber packing all as specified and directed for size 100mm bore of pipe line complete all as specified and directed. 50 SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY)for details refer pdf folder 51 SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY) 52 Supplying, installing, commissioning and testing of transformer outdoor type step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC, 50 Hz, 160 KVA, copper wound, Energy Efficiency Level-III type, with offload changing arrangement on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5 % including suitable cable entry boxes on LT side and HT Bushing on primary side complete in all respects with standard accessories and fitments confirming to IS-1180 (Part-I & II):2014 as specified and as directed including the following- 53 (a) Earthing terminal and rating diagram plate(b) Air release device(c) Oil filling inlet pipe with plug(d) Drain outlet pipe with brass gate valve with dummy plug(e) Conservator with level gauge(f) Silica gel with breather(g) First oil fill up to the recommended level by the manufacturer with new oil confirming to IS 335(h) Type of connection - Delta/Star(j) Type cooling- ONAN(k) Vector group - DYN 11 54 (l) Type of connecting arrangement - ACSR conductor connection on HT Side and cable connection box on LT Side(m) Provision of thermometer with pocket(n)(o) Oil and winding alarm and trip relay including marshal box(p) Platform of Size 3.0x 3.0 x 1.2m height from ground level with stairs including excavation, PCC 1:5:10 type E2 in foundation, brick work in CM 1:6, PCC 1:2:4 type B1 in coping, plastering 10mm thick in CM 1:6 on brick/concrete surface and on top covered with GI chain link fencing 1.20m high gate of mesh size 50 x 50mm and GI wire dia 3.15mm incl suitable size of angle Iron, nuts & Bolts etc. and deemed included unit rate quoted by contractor against this item of transformer. 55 Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-55 (11.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection , including writing of pole Number complete all as specified and directed by the Engr-in-Charge. Note:(1) All excavation & earth work as involved shall be measured & paid seprately.(2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items. 56 Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection , including writing of pole number complete all as specified and directed by the Engr-in-Charge. Note:(1) All excavation & earth work as involved shall be measured & paid seprately.(2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items. 57 M & L including testing and commissioning of NATURE Switch for outdoor lighting automation using space grade sensors and an advances micro controller suitable for outdoor use having features Automatic Switching ON at Sunset, Automatic Switching OFF at dawn, No clock setting and time settings wide operating voltage range, High voltage trip and auto reset having specification 415 Volts, 50 Hz, 04 Nos incomer MCBs of suitable ratign with auto and manual arrangement including 03 Nos contactor and suitable rating outgoing MCBs single pole type complete with all connected accessories of rating 12 KW 3 phase, current range 40 Amps all as specified. Make- KAKTIYA ENERGY SYSTEM Model No- SWADEEP-02EC12KWP3P or eqvt 58 Material and Labour for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, (SIZE NOT LESS THAN-1200X1200X500 MM, LXWXD) Outdoor type, totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side openable, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, 59 with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -a)Busbarchamber :Electrically grade copper shrouded bus bar of capacity 400 Amps for each phase and 400 amps for Neutral andcurrent density 0.8/Sqmmincluding interconnection of all switch gears, fixed on DMC insulators and provision of extension. 60 Note- The panel shall be free standing on angle iron having size 65x65x6 mm and height 900mm long with 04 Legs with base support of MS flat of size 100x100x6 mm complete with following scope of work-INCOMER :(i) MCCB 250Amps, 415Volts, 4 pole 50 Hz, 36 KA with adjustable , thermal magnetic release in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs of suitable ratio 400/5 amp , 5 VA class 1.0 (set of three) = 01 set. 61 (iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(iv)AC three phase LT/CToperated multifuctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical, backlit LCD display, measures and display, trivector energy and load survey, TOD temper detection and lodging power on/off events, instataneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three).(vi)MCB SP 6Amps 10 KA,for control protection RYB phase (set of 3)-01 set. 62 Outgoing:Outgoing with one compartment each comparment will consist the following :(i) MCCB 160 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 02 Nos(ii)MCCB 63 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 01 Nos (iii) MCB SP 16 - 20 Amps10 KA- 01 Nos 63 Supply and fixing polycarbonate kiosks box suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 amps with one NoMCB 16 Amps, SP having size 300X200X150 mm complete including making fixing arrangement on 9 mtr long swaged pole with flat iron clamp including connection from light fitting to junction box with 1.0 sq mm, 3 core wire all as specified and directed by Engr-in-charge. 64 Supply fabricated and fixing street light bracket made out of GI pipe 1.2 mtr long 40/50mm dia medium grade bent to shape including clamps made out of 40 x60 mm flat iron for steel tabular pole, nuts, bolts including painting all as specified 65 Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified. Note :- Punned thickness shall be measured and paid. 66 SCHEDULE A PART XII A (LIFTS)for details refer pdf folder 67 SCHEDULE A PART XII B (LIFTS) 68 Design, supply, install, testing & commissioning of lift carry 8 passengers , cap 554 kgs, speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door)including one fireman switch which will be activated in case of fire incident including wiring and talk back facility complete including cable etc all as specified 69 Design, supply, install, testing & commissioning of lift carry 13 passengers , cap 884 kgs, speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) including one fireman switch which will be activated in case of fire incident including wiring and talk back facility complete including cable etc all as specified 70 Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 4 core. 71 Providing manpower & operation of 4 x pessenger lifts at Clement town military station by providing manpower 01 x Un-skilled lift operator per shift in a day for 8 hrs including Sunday & holiday and carrying out minor regular / periodical repairs and regular servicing for upkeep the passenger lift serviceable in all respect, checking of oil levels, thorough checking of lift, make the machinery /equipment dust free, including thorough cleaning up of battery terminals of ARD unit, greasing/oiling of moving parts, leak testing etc all as specified and directed by the Engineer-in-charge. (Note:- (i)The duration of work will be carried out in three shifts from 0600 hrs to 1400 hrs (First Shift), 1400 hrs to 2200 hrs 72 (Second Shift) and 2200 hrs to 0600 hrs ( Third Shift). (ii)The duration of work will be carried out in three shifts of 08 hrs of each shift by deploying the manpower 02 x Un-skilled lift operator in each shift (Total 06 operators in one day) to operate the 04 Nos automatic lift ( 02 x 08 passengers & 02 x 13 Passenger) in high rise towers of G+6 storey). [24 months for DLP & 36 Months after DLP] 73 Comprehensive maintenance of all mechnical & electrical components & conduct a thorough inspection of the fully automatic 04 x passenger lifts ( 02 x 08 passengers & 02 x 13 Passenger) in two high rise tower of G+6 storey) with mechnical & electrical systems, including motor, cables, brakes, control panels & wiring. Identify any signs of wear, drainage or carring out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair / maintenance of unserviceable parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes, door cards, car door sills, landing door sills, 74 door locks, control cards and its contacts, hall push buttons and its spares, connector / links, welding of crack/broken and MS parts,kanding operating panel of any size & capacity, repair / maint of u/s damaged door safety edge & sensor mechnical safety locks, megnatic lock of contact, car position indicator & all connected accessories, necessary wiring of hall push button assembly, repair/ mantenance of broken COP/LOP buttons & 75 display including cover, fire alarm, firemen button glass, intercom, alarm/hooters, maintenance of damged hand rail shaft, light / switches , complete with illuminated push button & direction indicator with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors & safe operation of lifts, fixing of loose rail brackets if any, cabin mirror light & minor repair of cabin fan, ensure safe & smooth functioning of lift & complete maintenance of car top, binding of loose wire at control panel & rust painting at car top and door, dewatering of lift well in case of any emergency arise all as directed by Engineer-in-charge. [ 36 Months after DLP] 76 SCHEDULE A PART XIII A (DG SETS)for details refer pdf folder 77 SCHEDULE A PART XIII (DG SETS) 78 Supply ,installation ,commission and testing totally enclosed type (silent operation with canopy,CPC B-IV approved ),static type Diesel Engine driven,Generating set of 40 KVAcapacity confirming to BS-5514/IS -13018:1990(Engine) & IS-13364/IS-4722 (Alternator), 4 wire 50 HZ415 Volts supply under NTP conditions when running at 1500 RPM complete including Engine Alternator mounted on common base plate of rigid fabricated mild steel base frame all as recommended by manufacturer and having following provisions all as specified and directed . 79 The silent canopy shall be as per the Central Pollution Control Board norms . The silensor canopy shall be manufacturerd by the manufacturer of the engine itself . The make and model of generator set to be installed with engine details ,alternator specifications and specification of silensor canopy shall be got approved from GE before order is placed by the contractor to the manufacturer. 80 (A) Alternator:- Alternator shall be of capacity of 40 KVA net out put at work site after considering derating factor as per MSL height and NTP conditions as applicable at power factor .85,AC , 3 phase , 4 wire, AVR system, screen protected . Ball / roller bearing with damp proof copper windings on each pole to base as per IS-13364/IS-4722 complete all as specified . 81 ( B ) Diesel Engine :- Diesel shall be of adequate capacity suitable for above alternator after derating factor as per MSL hight and temperature for work siteand as per relevant IS code having provision of coupling shaft to drive the above Alternator independtly after considering power losses in all the accessories forming part of the set i.e. couplings any type FIP , water cooler, direct injector ( if provided ), fan etc. Engine should be multistage, vertical multi cylinder water cooled, 4 stroke, direct injection cold starting , RPM1500, industrrial type standard accessories complete in all respect including all provisions as recommended by manufacture and following provisions complete all as specified and directed. (Note: DG set will be conforming to notification of Min of Environment date 17 may 2002):- 82 (i) Fly wheel with housing .(ii) Air cleaner dry type(iii) Corrosion resisiters.(iv) fuel filter, Oil filter (v) FIP system including pump injectors solenoid controls , nozzles, govenors etc(vi) Radiiator including water pump with fan (vii) Cylinder with buffers, tail pieces duly insulated with asbestos/ lagging and sufficiently extended to carry exhaust outside theDG Set building. 83 (a) Lead acid battery 12 volts , 90/100AH = 01Nos. initially chargedMake :- Exide/Prestolite/ AMCO ( Maintenance free type)(b) Self Starter.(c)Alternator12 volts DC complete with holding clamp. (d) Start / Stop push button ,ignition switch with key system.(e) Battery charging system including regulator and generator / alternator 84 (viii) Engine shallbe with turbo charger.(ix) Engine protection device against low lubicating oil pressure, high water temperature ,and high oil temperature ,over speeding of engine etc.(x) Water temperature gauge, oil temperature gauge, oil puessure gauge ammeter for display charging + Amps etc. 85 (C) ACCOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing accustic enclosures suitable of 40 KVA capacity diesel Generator set duly fabricasted of channel and CRCA sheet 16SWG of required size having doors , insulation sides and top by minralrock wool confirming to IS-8183 of adequate thickness accoustic louvers /outlet. ventilation system etc . complete as per manufacturers instructions with wiring and lighting arrangements duly painted of three coats of dulux gloss synthetic enamalled paint over a primer coat or as directed of suitable size all as required at site and comprising of the following :- 86 (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section .(ii) Structure heavy duty rectangular MS box channel .(iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks .(iv) Out side cover: Made out of CRCA sheet 2 mm thick.(v)Accustic insulation ( side &Top )sound proofing minerla rock wool slab of density 96Kg/m3confirming to IS 0183 thickness 100mm covered by fire Resistant fiber tissue as per manufacturer recommandation .Test report from original manufacturer to be submittedbefore incorporation in the work for authenticity of material .(vi) Inside cover : CRCA perforated sheet 0.6mm thick powder coated .(vii) Inspection port : Aluminium frame with double wwalled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel . 87 (D)AMF CONTROL PANEL:- As per manufacturers design with the following equipments. (a) 2 Nos. , 3 pole, suitable ratingcontactor -L&T,Crompton, C&S,GE.(b) 02 Nos MCCB of sutable type and rating for DG/Mains incoming-L&T/GE/ C&S(LG ).© Frequency meter -Enercon/Caddle/ AE/ C&S(LG).(d) Ammmeter with suitable CT,s with selector switch-Enercon/Caddle/AE.(e)Voltmeter with suitable switch-Enercon/Caddle/AE.(f) Frequency meter -Enercon/Caddle/AE. 88 AMF logic :The AMF panel shall be provided with micro processer based programmable logical control system of Make -C&S (LG) /UTOPIA /SIEMENS. The control system will have the fillowing option:-(a) Start/ stop settings including delay and timing setting duly programmable.(b) programmable timing for idle running .(c) Auto/ manual option for each contractor .(d) Self starting kiks for three times or as per programme .(e) Alarm for any fault with buzzer and indicating lamp .(f) One main supply voltage monitor .(g) One alternator supply voltage monitor .(h) One set of DC control relays and timers.(j) One set of control relays for the automatic control system . 89 (E) RCC FOUNDATION:- RCC FuoundationM 20(as per manufacturer design) ,450 mm overall height, 300mm above floor level and 150 mm below floor level of required size. (Make of Engine :-Cummins/Kirloskar/ Ashok leyland /Ruston/Greaves.(Make of Alternator:-Kirloskar/Jyoti/Stam Ford,Alston, Electric, Jyoti . 90 (F) Acoustic Louvers / Attenuators at Air inlet/outlet :-The acoustic louvers provides excellent sound attenuation and good weather protection. Single blade and chevron blade louvers are manufacturefrom 16 SWG CRCA sheet top section with an acoustic in fill of resin bonded mineral rock wool has a density of 96 Kg/m3 .The under section is formed from 18 SWG CRCA performed sheet after covering with resistance tissues to prevent fire migration or by means of acoustic lined ducts. 91 (G) FUEL TANK :- One No of sheet metal steel tank of suitable capacity of hold diesel sufficient for 12 hours running at full load, mounted on angle iron frame including the following:-(i) Level indicator to indicate level of diesel in tank. (ii) Drain plug with 2.0 mtrs pipe for draain oil.(iii) fuel strainer.(iv) Pipe for fuel.(v) Air vent.(vi) Mannually operated one no. fuel pump. 92 (H) INSPECTION PORT :-Aluminium box frame with double welded glass fix type sealed with neoprene rubber gasket, for viewing instrument panel.(J) VENTILATION :- Forced with suitable fan. 93 (K) WIRING AND LIGHTING :-PVC copper wire concealed in flexible conduit provided with florescent tube light and MCB.(a) Earthing panel (Neutral body).(b) Control Panel .© Cable leads for batteries.(d) Power cable to euipment.(e) Self StarterNOTE :- (a) Generating set will be placed on suitable foundation as recommended by manufacturer .and cost thereof shall be included on the prices quoted .(b)Tools shall be supplied as per manufacturer,s instructions and cost thereof shall be included in the price quoted . 94 SCHEDULE A PART XIV A (Fire Alarm & Fire Fighting) 95 SCHEDULE A PART XIV B (Fire Alarm & Fire Fighting) 96 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade 97 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,4 core, 1100 Volts grade 98 Supplying installation testing and commissioning of addressable electronic Hooter with audioable range of 25 to 30 mtr with suitable output wattage.These Hooter should be such that they are capable of public announcement as well as used for fault as requried. 99 S & F active repeater ,silence ,mute, reset,accept,evacute and test controls, DX control panels require a 24 V dc supply and an RS485 card required when used with ZX control panel. 100 Fire pump electric driven engine horizontal end suction cetrifugal type as per relevant IS with CI casing bronze impeller and stainless steel shaftmounted on heavy duty bearings suitable continuous operation 0-150% of rated capacity for 415 Volt 3 Phase 50m Hz AC supply for discharge head 900 LPM at 36 m Head complete with automatic start system in case electric supply failure and mannual Start off having battery of appropriate rating, self starter,foundationcomplete all as directed by Engineer-in-Charge. makes: shakti pumps india ltd/Kirloskar/CG 101 Supply, installation, testing and commissioning out door type cubical panel board outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 3.15 mm thick CRCA sheet and MS angle of suitable size on PCC 1:2:4 type B-1 platform frame factory fabricated with front and back open able double door systemlouvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, factory fabricated (Factory approved from CPRI)having modern fabrication and followed by powder coat painting comprising of the following:- (Main Elect Panel ) 102 (a) MCCB 415 volts .4P ,200 Amps 16 KA(incoming)-01 No(b) MCCB 415 volts .4P,63Amps 16 KA(O/G)-03 Nos (for Fire pump & lift)(c) MCCB 415 volts .4P,63 Amps 16 KA(O/G)-01 Nos (for Fire alarm Panel)(d) MCCB 415 volts .4P,100Amps 25 KA(O/G)-01 Nos (for bldg)(e) Space for starter - 01 No(f) Bus bar chamber with and including Aluminium strips (set 4 nos) suitable for 300 ampsduly mounted on porcelain insulators-01 Set(g) DigitalAmp meter 3 phprogrammebale type with suitable CTs -01 Set(h) Digitalvolt meter 3 phprogrammebale type suitable for 500 Volt -01 Set (j)LED Phase indicator R, Y & B-01 Set 103 S&F water type extinguisher(IS: 15683) 9kg capacity 104 S& F light weight squeenze grip type CO2 Extinguisher(IS: 15683) 4.5 kg capacity 105 S&F Dry power (ABC) extinguisher(IS: 15683) 9 kg capacity 106 S&F Dry Mechanical foam extinguisher (IS: 15683) 9 ltr capacity 107 S&F Fire buckets(Dry sand) (IS:2546) 108 S&FFire bucket stand post 109 SCHEDULE A PART XV (Heating Appliances) 110 SCHEDULE A PART XVI (Lightening Conductor) 111 SCHEDULE A PART XVII (Dismantling / Demolition)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 14
Uttarakhand View Result →
23.
Educational and Research Institute #9832816 AOC
PROCUREMENT OF MACHINERIES, INSTRUMENTS, TOOLS AND EQUIPMENTS ETC. RELATED TO ELECTRICAL ENGINEERING AND ELECTRONICS AND TELECOMMUNICTION ENGINEERING LABORATORIES AND WORKSHOPS OF MATHABHANGA GOVERNMENT POLYTECHNIC, MATHABHANGA, COOCH BEHAR, WEST BENGAL- 1 ANALOG ELECTRONICS LAB-I (3RD SEM) 2 50 MHz Dual Channel CRO• Automatic Measurements of Signal Parameters like .Pk-Pk, Average, Max. , Min., rms, top etc. Voltages and Frequency, Period,Width,Duty Cycle, Rise Time, Fall Rime • Waveform and Set up storage facility.• Colour Display. • Advanced features like sequential acquisition of up to 1000 trigger events should be possible.• Standard USB Host & Device Connectivity. • Standard 23 Automatic Measurement andMath Function Including FFT.• Education student Lab guide and professor slide set.DETAILED TECHNICAL SPECIFICATIONS:-a)No. Of Channels:2b)Bandwidth :50 MHzc)Maximum Input:400 V (peak ac + dc) d) Sample Rate :1 GSa/sece)Waveform Update Rate : 400 Waveforms/secf)Memory : 16 Kpts/Ch.g)Time Base : 5nsec / div. To 50 sec./div.h) Resolution : 8 bitsi) Display: 5.7 inch Colour QVGA TFT LCD Display.j)Trigger Modes: Force, Edge, and Video, Pulse width.k) Built In Interface : Standard USB 2.0 (Host and Device)l)Power Supply: 230 V AC Supply, 50 Hz. 3 Function Generatori)Itshould be a waveform / function generator which can be upgraded to an arbitrary waveform generator . It may also have the feature upgrade the frequency of operationii) Should have low harmonic distortion and jitter.DETAILED TECHNICAL SPECIFICATION:--• Frequenc : 1Hz. to 20 MHz for Sine , Square and PulseWaveforms and 1 Hz. to 20 MHz. for Noise• No. of Channels: 1• Frequency Resolution : 1Hz.• Amplitude : 1 mVpk-pk to 10 v (pk - pk) in 50 ohms. • Duty Cycle for Pulse : 0.01 % to 99.99 %• Standard Waveforms: Sine,Square,Ramp,Pulse,Triangle,•Operating Modes: Continuous,Modulate,. .• Modulation Types: AM,FM,PM,FSK,BPSK,PWM• AM : Source both Internal & External, Depth 0 to 120 %With 0.01 % resolution.• FM : Source both Internal & External, Deviation 1Hz to 15 MHz• PM: Source both Internal & External, Deviation 0 to 360 deg C.• PWM : Source both Internal & External. Deviation 0 % to 100 %.• Power Supply : 230 v,50 Hz. ac. 4 Digital MultimeterDC Voltage:400mV to 1000V , AC Voltage: 400mV to 1000V,DC Current: 4mA to 10A, AC Current: 4mA to 10A, Resistance: 100 ohm to 40Mohm, Resistance: 100 ohm to 40Mohm,Capacitance: 4nF to 200µF, Duty Cycle: 0.1% to 99.9%, Frequency: 10Hz to 10MHz, Temperature: 20oC to 750oC,Transistor Test: Yes (for NPN & PNP), Diode Test: Yes, Continuing Buzzer: Yes, Power Supply: 9V, Manual and Auto ranging,Display: 4½ Digit 5 To study the V-I characteristics of UJT Trainer kitVariable DC Power Supply 1.2V to 12V/500m,A DC Power Supply for DPM 5V/500m,A UJT (2N2646) UJT Characteristics UJT Relaxation Oscillator with two different Timing Capacitors ,DigitalMeters for Measuring Voltage and Current ,Set of Patch Chords & User Manual 6 To study the input and output characteristics and to find the h-parameters of a BJT for : —(a) C-E configuration,(b) C-C configuration,(c) C-B configurationHARDWARE SPECIFICATIONS :Dual Variable DC Power Supplies 0V to 12V/500mA and0V to 15V/500mA DC Power Supply for DPM 5V/500mAIndependent Base Limiting Resistors - 2 Nos.(low value) Independent Collector Resistor - 1 No. Transistor( NPN Type SL100) .All Inputs/Outputs through 2mm Sockets set with provision of Digital Multimeter for measuring input and output. 7 ANALOG ELECTRONICS LAB-II (4TH SEM) 8 Feedback Amplifier Trainer12 V DC supply with +/- 10%accuracy,configurable circuit,Inbuilt sine wave generator with frequency range 10 Hz to 10 KHz rangeand Amplitude variation 10mV to 4V, NPN transistor. Voltage Series & Shunt and Current Series & Shunt configurable operation. 9 Oscillator Trainer KITi) Hartley, Colpitt ,Wien Bridge Oscillator Trainer kit : i) NPN Transistor ii)On boardoscillator section,separate tank circuit (iii)Biasing Voltage :+12 V , -12 V ,+12V SMPS Adaptor provided with the trainer for power supply.Designed by considering all the safety standards. Provided with an extensive manual.Power Supply to Kit: 230VAC,50Hz, All interconnections are made using 2mm banana Patch cords 10 To determine the following characteristics of op-amp: —a) input offset voltage, b) slew rate, c) non-inverting gain, d) inverting gain e) adder, f) subtractor, g) differentiator, h) integratorandi) voltage followerTo adjust offset null, setup the closed loop amplifier using IC741 op-amp also to (a) dc gain (b) ac gain. The set complete with +/-12V DC regulated power supply with milli voltage source, Null arrangement and 2V/20V dual range digital voltmeter , In built sine wave,triangular wave & square wave Generator of1 KHz, 15V Vpp (approx.), DC Power Supply : 0 - 5 V (vary through (2No.) rotary switch for specific voltage level 11 DIGITAL ELECTRONICS LAB (3RD SEM) 12 Complete setup to implement encoder, decoder ,multiplexer andde-multiplexer5V D.C. at 100mA, IC regulated power supply,21 Input Switches for data input,IC For Multiplexing 74150 is provided on board with Combinational Circuit, IC For Demultiplexing 74154 is provided on board with Combinational Circuit, One Not Gate is provided on board using 7404 ,16 Output LEDs with driver circuit to observe the output of Multiplexer Demultiplexer, A Pulser to provide the pulses manually for triggering,230 V ±10% at 50 Hz A.C. Mains,necessary patch cords and user mannuals. 13 Complete setup to design / construct parity generator, checker andcomparatorDC Regulated Power Supply 5 VDC/150 ma,5 SPDT switches provided for selecting logic ‘1’ & logic ‘0’,2 output indicators,Sufficient no of 4mm Patch Cords for Interconnection,Power Cords 230v, 50Hz,necessary patch cords and user mannuals. 14 Complete setup to design / construct binary synchronous and asynchronous counterTrainer kit for binary Synchronous and Asynchronous counter. with power supply, display unit, patch cords, manuals and necessary IC. 15 Digital I.C TesterUniversal IC tester: 40 pin DIP ZIF socket, 50 cherry keys Key pad and 16 X 2 LCD Display, suitable for testing of Analog IC, Digital IC and 7-segment display. 16 A/D & D/A Converter TrainerFEATURESAnalog To Digital Converter• 8-bit descrete ADC•12-bit monolithic ADC IC•On-board signal generator with adjustable amplitude levels•On-board LED bank to observe digital outputs•Power supply : +5V, ±12V GND•Interconnection is provided by 2mm connectors•Experimental manualDigital To Analog Converter•8-bit binary weighted resistors DAC•8-bit ladder type D to A converter•8-bit D to A converter using monolithic IC•Simple construction using Op-Amp and resistors•Onboard switches are provided for digital pattern generation•8-bit digital inputs ranges from 00 to FF•Variable frequency counter to study the settling timeSPECIFICATIONS•8-bit binary weighted and 4-bit ladder type DAC are constructed using discrete components•8-bit monolithic DAC having settling time in the range of ns, wide power supply range, low power consumption, full scale error ± 1LSB•8-bit digital ramp ADC constructed using discrete components•12-bit monolithic ADC having conversion time in the range of μs, industry standard pin out, wide input range•8 onboard switches to provide digital inputs to DAC•8-bit counter running on external clock frequency to study settling time of DAC• Built inlow frequency clock generator•1 KHz sine wave with adjustable amplitude level•Onboard variable DC voltage source for studying unipolar and bipolar modes of ADC •12 output LEDs to observe ADC outputs•ADA operates on DC power supply (+12V,-12V,+5V and GND)•Interconnection is provided by standard 2mm connector•Extensive experimental manual is provided with the kit EXPERIMENTSAnalog To Digital Converter• To study and measure resolution of ADC•To measure the conversion time of the ADC•To study full scale adjustment for unipolar and bipolar signals•To study the working of ADC 17 NETWORK ANALYSIS LAB ( 3RD SEM) 18 To study the series and parallelresonant circuitIndependent Resistors - 3 Nos. ,Independent Capacitors - 3 Nos.,Tapped Inductance. All Inputs/Outputs through 2mm Sockets Set of Patch Chords & User ManualWITH SIGNAL GENERATOR, COUNTER, DIGITAL METERS FOR INPUT & OUTPUT and user manual 19 To test and to measure the cut –off frequencies of the following: —(a) constant k-type low pass filter;(b) constant k-type high pass filterTwo Independent Passive LC Filter Networks (LPF & HPF) All Inputs/Outputs through 2mm SocketsSet of Patch Chords & User Manual 20 To study standing wave pattern for a transmission line of finite length with:(a) open termination,(b) shorted termination andmatched termination. 2.To measure the attenuation constant and phase shift constant for matched terminationTransmission Line Trainer Features:* 30-300 Mhz sweep source with detector* Calibrated attenuator* Displays standing waves/maxima-minima on CRO* Uses actual coaxial lines rather than simulated ones.* Impedance matching.* Measures VSWR, reflection coefficient, characteristic impedance, velocity of propagation, dielectric constant and signal attenuation in TDR.* Measure parameters of 50, 75 and 300 Ohms cables* Study Time Domain Reflectometry.* Study location and nature of discontinuities,Open/short, mismatched terminations, etc.* Offers a complete view of the transmission line in analog and digital domains, which is essential for complete understanding of transmission line behavior.Technical Specifications:A. Frequency Domain AnalyzerFrequency range : 30-300 MHz typical LCD Display. Level : 100mV p-p Attenuator 50 Ohms : 0.5, 1, 2,4, 8,15 dB,Output Impedance : 50 Ohms Scope out : X-Y output to scopeB. Resistive Impedance Analyzer ,Characteristic Imp. : upto 800 ohms ,Display : LCD C. Time Domain ReflectometerPRR Short range : 10MHz typical,Pulse width : <10ns typical, PRR Long range : 100KHz typicalAmplitude : 1V nominal, Output Impedance : 50 OhmsAccessories:Lengths of 50 ohms and 75 ohms coaxial cable, 300ohms, parallel line, lossy line, Tee connectors, ,Standard load of 50and 75 ohms, Various capacitive and inductive loads, shorts, Balun 1:1 & 1:4, Operating manual, Mains cord 21 COMPUTER PROGRAMMING LANGUAGE LABORATORY (3RD SEM) 22 Computer Programming Language LaboratoryTURBO C++ Software 23 MICROPROCESSOR LAB (4TH SEM) 24 8085Microprocessor Trainer KitHigh performance 8085A CPU operating at 3 MHz.16 K powerful monitor FIRMWARE expandable to 32 K. 64 K user RAM. Expanded RAM accessible using bankWrite protect facility for RAM. 3.6 V Ni-Cad battery back up. Versatile Keyboard/Display controller using 8279. 24 highly reliable dual function keys. 6 digit seven segment LED display.Parallel I/O lines available through two 8255 chips. Serial I/O through 8251 USART, with on-board level shifters 1488,1489.Programmable communication parameters. Built-in audio cassette interface.3 channels of 16 bit timer/counters from 8253.Powerful 8085 interrupt capabilities. On-board EPROM programmer with ZIF socket for programming 2716 to7512 EPROMs and various EEPROMs. Normal and intelligent programming modes.On-board ADC,DAC, opto-isolator, reed relay and miniature speaker. On-board logic probe.Single stepping, break pointing and machine cycle single stepping facility. Monitor functions can be called through software interrupts. Large collection of application software provided. All address, data and control lines from the CPU, buffered and brought out on 50 pin connector. Additional Stepper motor of specification:Shaft type: 5 mm DCurrent rating: 1200 mA2Voltage rating: 4 VHolding torque: 44 oz·inSteps per revolution: 200Resistance: 3.3 Ohm2Inductance per phase: 2.8 mHNumber of leads: 6Lead length: 30 cm 25 Microprocessor 8086 Trainer KitINTEL 8086CPU AT 4.77 MHZ CLOCK SPEED,16KB for monitor EPROM upgradable to 64kb16KB RAM expandable to 64KBBattery backup provision for RAM upto 64KB16 x 2 (or) 20 x 4 Alphanumeric LCD display101 keys IBM compatible keyboard24 TTL I/O lines brought out to two nos., of 26 pin FRC connector1 number of standard RS232C compatible serial port brought out to a pin D type male connector.3 channel 16 bit counter/timer using 8253.Fully buffered address data and control signals terminated at a 50 pin header(VXT BUS) for interfacing VBMB seriesof experiment boards and bus expansion.8 no’s of interrupt lines are terminated at a 10 pin connector.Kit operates with a single +5V/DC supplyThe kit and the power supply are mounted on a attractive light gray color fiber glass cabinet with fiber glass top cover.Built-in line assembler & DisassemblerPowerful debugging monitor to develop user program. 26 ELEMENTARY COMMUNICATION ENGG. LAB 27 To study the amplitude modulation and demodulation Ttrainer kit Features of Amplitude Modulation and Demodulation Trainer:On-board message signal with variable Amp/Freq On Board carrier signal with variable Amp/Freq AM Modulation using MC 1496 IC Demodulation using Diode Detector and LPF,6th Order LPF,Op Amp Based Variable AmplifierInternal Power Supply +5V , +12V/ 500 mATechnical Specification :Message Signal:Sine wave Frequency 100 Hz to 2.8 KHz, Amplitude 0 to 3VCarrier Signal: Sine wave Frequency-28 KHz to 108 KHzAmplitude 2V,Modulation : Balanced ModulatorAmplifier : Op Amp BasedDemodulation : Diode Detector & LPFLow Pass Filter : 6th Order LPFSupply Voltage (Board) : +12V, +5V / DCSupply current : 100 mA (Minimum)Input Voltage : 230 V/ 50 Hz ACInterface connectors : 2mm socket 28 AM/FM Radio Receiver kitFrequency range: 400KHz ~ 1.5MHzIntermediate frequency: 455KHzInputs: RF signalOutput IF frequency: 455KHz adjustableIF filter: Dual tune LC, RF amplifier with variable gain ,Mixer (frequency converter),Local oscillator:Output Signal: Sine waveFrequency range: 400KHz ~ 1.5MHz ,Amplitude: Adjustable from 0Vpp ~ 2VppOutput impedance: 50 Ohm ,1st and 2nd IF amplifierCentral frequency: 455KHz, Load impedance: Variable R-L-CGain: 40db with automatic gain control, Diode envelope detectorDetection of the envelop with variable RC filter. Audio output:Amplifier with audio jack, Audio amplifier gain: 26Db, Receiving media :MW coil antennaFM radio receiver, Reception range: 88MHz ~ 108MHz with continuous tuningTuning circuit: Using GANG capacitorIntermediate frequency: 10.7 MHz with ceramic filterEXPERIMENTS:Study of double sideband AM reception using envelope diode detector,Study of single sideband AM reception using product detector,Study of image frequencies,Study of adjustment of receiver tuned circuits,Voice reception using DSB/ SSB AM receiver (super heterodyne receiver)Effects of switch faults FM detection output level: 77.5Vrms (typical)FM detection output distortion factor: 0.3% (typical)Audio amplifier: Gain up to 46DbReceiving media: Adjustable telescopic antennaPower supply: -12V,+12V,+5V,GNDOutput volume regulation, output load impedance of 8 OhmEXPERIMENTS AM radio receiverTo study AM radio receiverTo study of image frequencies for AMFM radio receiverTo study FM radio receiverTo measure the frequency response of Audio amplifier 29 Pulse code Modulation and Demodulation system trainerInbuilt variable DC and 1 kHz AC Modulating Signals, Facility for applying external AC or DC Modulating Signal, Modulating circuit consists of a Positive Clamper, Sample and Hold (S and H), Analog to Digital Converter (ADC), Parallel to Serial Converter and Control Signal Generator, Observation of binary coded analog information by the LED status for both Modulation and Demodulation, PCM Modulation technique using IC, Built-in Pulse Code Demodulation circuit using a Serial to Parallel Converter and Parallel Shift Register DAC, Low Pass Filter for both AC & DC, Observation of Modulated & Demodulated waveform, Provision to monitor output on CRO, Clock to be provided from the Pulse Code Modulator to Demodulator circuit, Built-in IC based DC Regulated Power Supply with indication for power ON & fuse, 4 mm Patch Cords – 4 nos, Supply required 230V, 50 Hz and 1 phase AC, Comprehensive instruction manual complete with theory and operating details. 30 Frequency Modulation andDemodulation kitFM Modulators :Audio Oscillator : Sine wave (10Vpp adjustable) Frequency (300 Hz - 3.4 KHz) FM Modulators : 3 nos. • Reactance Modulator : Carrier Frequency - 455 KHz (± 3KHz) Varactor Modulator : Carrier Frequency - 455 KHz (± 2KHz) VCO Based Modulator : Carrier Frequency - 10 KHz - 200KHz (adjustable) ,Mixer / Amplifier adjustment FM Demodulator:Detuned Resonant DetectorQuadrature DetectorFoster-Seeley DetectorRatio DetectorPhase-Locked Loop Detector (IC HEF4046 based)Phase-Locked Loop Detector (IC LM565 based), Low Pass Filter : 3.4 KHz Cut off Frequency Amplifier (with adjustable gain) 31 DPCM & ADPCM MODULATION / DEMODULATION KITDPCM & ADPCM MODULATION / DEMODULATION KITOn Board Signals:. Frequency: 500KHz, Amplitude: 0 to 4 v pp 32 CONSUMER ELECTRONICS LAB (4TH SEM) 33 Black & White TV Trainer kit with provision of fault findingSystem: CCIR-B, 625 lines, Power supply :230V Ac, 50 Hz, Regulation range170v Ac to 270v Ac.,Power consumption :70 watts,Gain Limited sensitivity:55 dB for Video & 25 dB for AudioSound output :2.0 watts maximum. Screen size :20 Diagonal. Channel :VHF 2 to 12, UHF 21 to 68,S-band and Hyper-band. Isolated shockproof chassis. Sections:Electronic tuner, VideoI.F Section, Sound I.F, Video amplifier, Horizontal oscillator, Horizontal driver and EHT, Verticaloscillator, and output, S.M.P.S power ,Controls: Volume, tone, Brightness, contrast. Distortion :10 to 15% in Live program due to expanded P.C.B. All parts are soldered on Tags on SINGLE PCB of size 19x15” with complete circuit diagramSCREEN PRINTED in different colors with FAULT CREATING FACILITIES to create more than 25 faults. Standard Accessories : 1. Frame with PCB mounting.2. Picture tube fitted in wooden cabinet 3. A Manual having 20 practical. 34 DTH TV and SET TOP BOX TRAINER KITPower supply 230 V ,50 Hz, Input frequency: KU Band, Output frequency: 950-1450 Mhz.Noise temp: 35 degree,DISH ANTENA ,LNBIF FREQUENCY: 70 MHz 35 Colour TV Trainer with provision of fault findingStandard : CCIR-B-PAL-G, 625 Lines Channels : 230, 2 - 4 VHP I (VL), 5 - 12 VHP III (VH), 12 - 100 : BAND IV & V, else : S BAND & HYPER BAND Picture Tube Size : 36 cms. Diagonal RF Input Impedance : 75 W (Ohm) 36 DIGITAL & MICROWAVE COMMUNICATION ENGG. LAB 37 Spectrum AnalyzerFrequency range:9 KHz to 26.5 GHz,Phase noise :-102dBc/Hz, Max third order dynamic range, 1 GHz: 111dB, Displayed average niose level,1GHz:-163dBm,Standard attenuator range/step:50dB/10dB,70dB/10 squaredb,Overall amplitude accuracy:+/- 0.50dB 38 Antenna Trainer 86 - 860 MHZSPECIFICATIONS:Radiation pattern plotting software• Stepper motor controlled receiver stand.Antenna Measurement System:RF Source•Source types :PLL Synthesized with integrated VCO• Frequency range :100MHz to 3GHz• Dynamic range :85dBm• Transmitted power min:-50dBm• Transmitted power max:+5dBm • Impedance :50W / SMA RF Detector• Detector type: logarithmicdetector• Frequency range : 1MHz to 8GHz• Resolution: 0.1dB• Dynamic range : 85dB (±3dB)• Noise level : -90dbm• Impedance: 50W /SMA• Representation of RF level : dBmDisplay•128x64 Graphic LCD Display with backlit. Keypad•15 Key Membrane Keypad for user entry.Stepper motor controller•1.80 Resolutions.List of Standard 22 Antenna Suppliedwith the setupWire Antenna1.Monopole Plane base ground2.Dipole (2nos.) 3.Yagi4.Folded Dipole 5.Vee Dipole6.Rectangular Loop 7.HelicalMicrostrip Antenna 1.Planar Dipole 2.Planar Monopole3.CMSA 4.TMSA5.2X1 ARRAY 6.Annular ring7.Chip Antenna8.RMSA9.RMSA- Circular PolarizedAperture Antenna 1.E- Horn2.Open ended Waveguide Rectangular Array Antenna 1.Broadside Array2.Collinear ArrayReflector Antenna 1. Corner reflectorSOFTWARE• Radiation pattern plotting and analysis software suitable for windows environment Antenna PositionerThe Transmitter and Receiver Antenna stand is made of special material which is inhert to EM frequency and it has engraved height and angle scale on It. It has facility to adjust the height and level. Universal plug and fix Antenna mounts are provided to hold the antenna assembly in vertical and horizontalorientation for co and cross polarization.ACCESSORIES • SMA (M) to SMA (M) 50W flexible cable : 02nos• USB cable ( Male A to Male B): 01no• 3 Pin 6 Amp Power chord: 01no • Manual : 01no • Software on CD: 01no EXPERIMENTS• Measure the variation of field strength /inverse square law• Prove the reciprocity theorem of antenna• Plot Radiation pattern of WIRED Antenna Omni directional antenna• Plot Radiation pattern of all Aperture Antenna• Plot Radiation pattern of all Reflector Antenna• Plot Radiation pattern of all Array Antenna• Measure co-polarization, cross polarization 39 Microwave Test Bench (KLYSTRONBased)Klystron Power Supply: Specifications:Input Voltage -230V+/- 10%, 50Hz AC, Beam supply- Voltage:200-450V continuously variable; Current:Regulation: better than 0.5% for +/-10% variation in mains supply voltage; Ripple: less than 5mV rms ,Repeller Supply -Voltage:-10V to -270V continuously variable with respect to klystron cathodeRegulation: better than 0.25% for +/-10% variation in mains supply volt , Heater Supply - 6.3V DC (regulated)Modulation- Square Wave : Frequency 500Hz to 2000Hz; Max. Amplitude- +110V peak to peak, Amplitude and frequency continuously variable; Sawtooth- Frequency 50Hz to 150Hz; Max. Amplitude- 60V peak to peak, Amplitude and frequency continuously variable.VSWR Meter: (Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Power : 230 Volts AC, 50Hz, mains supply) 40 ASK / PSK / FSK Modulation And Demodulation KitFEATURES•VLSI based design •Separate component and operational area •Acrylic cover for component safety •Modular organization of circuit functions •Test points to access signals at every stage of circuit operation •Multimedia based interactive e-manual Data Simulator: Onboard 8-bit variable NRZ-L pattern,Crystal Oscillator: 32.768 MHz,Data Clock: 256 KHz,Data Format: NRZ (L),Onboard Carrier Sine Waves : 1MHz (0°), 1MHz (180°), 500 KHz (0°),Power Supply: +12V, -12V, +5V, GND. 41 Microwave Test Bench (GUNN Based)Gunn microwave test bench:Gunn Power Supply (0 - 12 Volts variable,1 Amp. Max,Modulation Frequency: 1KHz +/- 10% (900-1100 Hz),Output Connector: BNC(F) for Gunn Oscillator & TNC(F) for Pin Modulator,Modulation: Square Wave, Frequency : 500Hz to 2000Hz)• Gunn Oscillator • Isolator• PIN modulator• Variable attenuator • Detector Mount• SWR meter(Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Powe : 230 Volts AC, 50Hz, mains supply) 42 1 GHz spectrum Analyser1 GHz spectrum Analyser with tracking generatorFrequency range: 150 KHz to 1000 MHzFreqency Resolution: 1 KHz CF entry 40 Hz sweep resolution at 2 KHz per Division,Frequency Display: 61/2 digitFrqency Control: Digital Phase LockResolution Bandwidth: 3 KHz, 30 KHz, 220 KHz, 4 MHz. 43 INDUSTRIAL ELECTRONICS LAB -I (5TH SEM) 44 Trainer Kit to study Reverse Recovery Characteristics of Power DiodesThe single Board trainer Kit should contain IC Regulated Power Supply, Different types power diodes, Digital Ammeter and Voltmeter and other necessary passive components 45 To study drive circuit of SCRIsolated 230 V/40 W AC Power Supply1.2 V to + 15 V/500 mA DC Power Supply* 0-18 V/500 mA,50 Hz, AC Power Supply* Variable frequency triggering pulses* DC Gate signal control, Pulse gate signal * Synchronous AC gate control signal through DIAC* UJT Triggering* 10:1 On- board resistive attenuator * Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 46 To study a single phase rectifier—output waveform with phase control circuitTrainer Kit to study Single Phase Full wave Bridge Rectifier for fixedDC output, Half Controlled and fully controlled rectification facilities with R and RL, loads 1000 Ohms 10 Watts, 14 ma @ 0.05 A inductive loads.The Single Board Trainer Kit contains :(i) Source for rectification of 4 to 24 V DC fixed and variable output @ a max of 500 ma helps to construct and study Series and Parallel resonance Circuit.(ii) Four Diodes and 4 SCRs in bridge configuration with gradual firing controls and necessary capacitive, inductive and Pie filter components.(iii) Digital Ammeter and Voltmeter. 47 To study a polyphase rectifierIsolated 230 V/40 W AC Power Supply Isolated stepped down 3 PH supply. * 3 Phase diode rectifier in open condition*Provision for Load& CRO output.* Electronic phase sequence finder.*Set of Patch Chords & user Manual 48 INDUSTRIAL ELECTRONICS LAB-II (6TH SEM) 49 Servo Regulator Stabilizer Study Kit500VA Servo stabilizer , 2 Amp Variac, Digital input & output meters, Lamp load, Set of Patch Chords & userManual. 50 To study a Jones chopperIsolated 230 V/40 W DC Power Supply, + 5 V/500 mA DC Power Supply* SCR Jones chopper* Gate firing pulses for Jones Chopper* 10:1 On-board Resistive Attenuator* Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 51 To study speed control of induction motor by voltage and frequency variationV/F CONTROLLER 1 HP, AC SQ. CAGE IND. MOTOR 1 HP,DIGITAL VOLT & AMMETER. 1 PHASE I/P & 3 PHASE O/P,3 PH & 1PH MCB PROTECTION 52 To study the speed control of DC motor by:(a) varying field current keeping armature voltage constant; and,(b) varying armature voltage keeping field current constant DC SHUNT MOTOR (FULL COPPER WINDING) .5 HP WITH BASE MOUNT FRAME 1 No VARIAC CONTROLLED 2 DC POWER SUPPLY ( 1 FOR FIELD & 1 FOR ARMATURE)DC VOLT & AMMETER DIGITAL………4 NosPANEL MOUNTED RPM METER………1 No.WHITE BAKELITE FRONT WITH CONN. DIAGRAM & WOODEN SAFETY BOX.METAL FRAME TABLE (Ply board with sun mica) CUM STAND FOR PANEL 53 Power Electronics Devices Trainer KitShould have Built in power supplyDC supply : +/- 12V, 500mA,Power supply 17V / 750mA,Regulated 13.5V/3A O/P mustbe provided as 12V Battery charging supply. Isolated DC supply +12V/ 300mA with isolated common.On board Inverter transformer of Primary : 230V & Secondaries 12-11-0-11-12/3AOn board Lamp load of 15W (100W) should be provided.AC supply : 230V AC line voltage must be made available on two banana 4mm socketsMust have Two pulse transformers of 1:1:1 are provided for isolation & supplying firing pulsesalong with required DC Power supply to experiment panel under test through 15 pin female ‘D’connector.R-L-C Load PanelMust have Load resistor of 10W / 40W --- 1no.Must have Centre tapped 3A choke 4mH/ 16mH each ----2nos.Must have Commutation capacitors of 10mF/100V -------4nos.Must have AC Paper capacitor of 4mF/440V ---1no. 54 PLC Trainer (EXPERIMENT 1-Use of simulation package for different function of PLC. EXPERIMENT 2- Verify function of logic gates by using PLC. EXPERIMENT 3- Write and verify ladder program for motor ON-OFF Control with two push button)HARDWARE SPECIFICATION:TTL Input Switches : 8 Nos,TTL Momentary Switches : 8 Nos., Proximity Switch : 1 No.,Optical Transducer (two state) : 1 No., Programmable LEDs : 8 Nos., Analog input 0 to 5V DC : 8 channels, Analog output 0 to 5V DC : 1 No., 4 to 20mA Transmitter : 1No., 4 to 20mA Receiver : 1No., Current Meter : 25mA FSD 1No.,Voltmeter : 10V FSD 1 No., Piezo Electric Alarm : 1 bit.Built-in power supply.Dedicated I/O interface card suitable for IBM computer suitable for ISA slot. SOFTWARE SPECIFICATION:This is a GUI based LADDER LOGIC SOFTWAREDRAG AND DROP (D&D) an instruction instead of typing an instruction. This eliminates errors in typing. All the instructions are displayed ON-SCREEN during Design time. Each and every element is directly addressed with their NAMES not by numbers or codes, which are very difficult to remember. Ex: At design time, you call a SWITCH#0 in your Ladder program by D&D the component called SWITCH#0, and that’s it, not by typing a few digits numbers or codes.Appropriate LIST boxes (input, output) open as you D&D an instruction in LADDER WORKSPACE.Ladder workspace is 24X100 instruction CELLs are available for your use.TOOL TIP features are available at the end of each instruction prompting you “what to do next”Very user friendly.Extensive ON-LINE HELP menu available.GUI based STATUS of the entire PLC is displayed during RUN TIME.Programs are saved, retrieved, edited by simply clicking on Menu list box.Extensive EDIT features are available. 55 Power Electronics Development TrainerSize of Breadboard : 172.5 mm × 128.5mmDC Power Supply :+5 V, -5 V 500 mA,+12V, -12 V 500 mA+15 V, 250 mA+35V, -35V, 250 mAAC Power Supply :18V-0V-18V ,0V-15VOn board Firing CircuitsFrequency range : 30Hz to 900Hz variableAmplitude : 12VPWM control of G1, G2, G3 and G4Duty cycle control of “Gate”Signal is 0 to 100%SCR Assembly : 4 SCRs 2P4M, 400V/2APower Devices : IGBT-G4BC20S, MOSFETIRFZ44N,UJT-2N2646, DIACDB3,TRIAC-BT136, PUT-2N6027Circuit Components on board : Electrolytic Capacitor 10µF, 63V,Electrolytic Capacitor 1µF, 63V ,Met. Capacitor 0.33µF, 63V ,Diode 1N4007, Inductor 220uH, 4.7µH, 10mH.Pulse transformer on board :2 nos. PT4502 1:1 and one is PT4503 1:1:1Load selector : 6 load resistances- 47E/7W,1K/1W, 1K/10W, 10K/10W,120E/5W, 2K2/2W.Test points : 10 nos (Gold plated)Power Supply (Mains) : 220V/110V, 50Hz/60HzIncluded Accessories :Bread boards : 2 nos.Connecting wires : 20 nos.2mm to 1mm Patch cords : 15 nos.2mm Patch cords (Red) 16” : 4 nos.2mm Patch cords (Black)16’’ : 4 nos.2mm Patch cords (Blue) 16’’ : 12 nos.Mains cord : 1 no.with i) Power Semiconductor Application Experiment Panel ii)CON / INV Panel iii)Triggering circuit / dv/dt Protection panel 56 ELECTRICAL & ELECTRONICS MEASUREMENT LAB (6TH SEM) 57 Digital LCR meterVariable measured- L,C,R and loss angle (D factor ) Measured frequencies: 1 KHz, 100KHzDisplay: 3⅟₂ digit , Resistance: 0 to 20 MΩ, 0.1 Ω , Capacitance: 0 to 20000μF, 0.1 pF Inductance: 0 to 20000 H, 0.1μH ,D factor: 0.01 to 8.0 with 1% error 58 Distortion Factor MeterFrequency : 20 Hz to 200KHz Distortion:0.1% to 100% f.s.d. in steps ,Input sensitivity: 100mV (r.m.s.), Input impedance: 1MΩ/160pF, Voltmeter range: 300μv to 300v f.s.d. in 13 range 59 To measure L & Q by Maxwell methodFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 60 To measure the unknown capacitance by Schering bridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 61 To measure the unknown frequency by Wein BridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER WITH FREQ. COUNTER & CRO SIG. O/P INBUILT& CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., BACKLIGHT LED & WOODEN HARD BOX 62 MICROCONTROLLER AND EMBEDDED LAB (5TH SEM) 63 Microcontroller Trainer Kit 1.Write a Simple Assembly Programs fora. Addition b. Subtraction b. Multiplication d. Division2. Write a Programs for (any two of the following)i. 4 x 4 Matrix Keypad Interfaceii. character based LCD Interfaceiii. Analog to Digital Conversion (On chip ADC)iv. Serial EEPROMv. Seven Segment LED Display Interfacevi. Interfacing With Temperature Sensorvii. Stepper Motor Interface8 BIT EMBEDDED MICROCONTROLLER TRAINERFEATURES•Single board design with various resources•Excellent training platform for embedded applications•Software development tools include assembler and ‘C’ compiler•Easy adaptability to different versions of microcontroller in the same family SPECIFICATIONS•Experimental board for 40 pin MCS51 and AVR family of microcontrollers•In-system programming (ISP) facility for many microcontrollers•Double RESET signal with manual key•Crystal frequency: 11.0592MHz•On-board RS232 compatible serial interface terminated in a 9 Pin D female connector•4×4 matrix keyboard•16×2 alphanumeric LCD connector (4-bit interface) and trimmer for contrast adjustment•Four 7-segment LED displays•I2C EEPROM (24Cxx)•Real time clock (DS1307) with lithium battery and SRAM•8-high current output port (500mA) for driving external loads•Two 12V sugar cube relays•Continuous tone piezo buzzer•Temperature sensor socket with thermostat functions•Four 8-bit A/D converter, one 8-bit D/A converter provided by PCF8591•All port-pins available on 10-pin box header•8 LEDs for easy logic state monitoring•8 input trigger switches using 8 push buttons•ISP programming with Flash ISP for AT89S51/52/8252/AVR•Infrared remote control receiver module IC supported•P89V51RD2BN•AT89S52 Installable software on CD•Programmers notepad : Free, open source, text editor•Flash ISP programmer software for 89SXX•Bascom basic compiler (demo version)•MIDE-51: An IDE for MCS-51 microcontroller•WinAVR : open source C compiler for AVR•Sample programs for peripherals DC 12V/500mA output power supplyEXPERIMENTS• Study of LED blink• Study of dancing light• Study of LCD display• Study of LCD-keyboard display• Study of 7 –segment display• Study of RC5 remote control test program• Study of analog to digital converter• Study of real time clock (RTC) 64 ADVANCE COMMUNICATION ENGINEERING LAB 65 To be familiar with the following network components:THIS WILL BE A FULL PACKAGE OF THE FOLLOWINGS:-** RJ5/CAT5CABLES 100 METERSRJ 45CONNECTORS 100 PCSCUTTER & CRIMPING TOOLS FOR RJ45/CAT-5CABLESCABLE TESTER/TRACKER…….. 4 PCSHUBS WITH ACCESSORIES & TOOL KIT NETWORK INTERFACE DIFFERENT CARD 66 COMPUTER NETWORK LAB 67 Network ComponentsCAT 5/5E/6 cable :100mtrs (Rs 2000/-), RJ 45 Connectors: 200pcs (Rs. 500/- )RJ 45 Crimping Tools: 05(Rs. 800/- each)LAN Cable Tester (RJ 45): 05 (Rs 1000/- each) 68 24 Port managed switchNo. of Ports: 10/100 Mbps 24 Ethernet ports, Switch Fabric: 32 Gbps, Form Factor: Rack Mountable,OS: LAN base Image, Console port: Availavble for configuration, Mac Address table: 4000 or higher, VLAN: Supported, MTU: 9100 with support for jumbo frames, Warranty: 3 years onsite comprehensive warranty including parts and labor plus onsite technical support with 24x7 69 24 Port Unmanaged switch24-port 10/100/1000Mbps Ethernet switch Wifi Router: 300 Mbps wireless router with 4 LAN ports and 1 WAN port 70 8 port HubExternal Power Supply, 8 Nos RJ-45 connectors for 10BASE-T/100BASE-TX,Ethernet Ports 8-Port, Capacity 1.6 Gbps, Wireless Speed 10 / 100 Mbps 71 Access points54 Mbps Access point for wifi network: No.of Channel: Dual channel for support upto 108 Mbps ( 2x54Mbps), Backbone connectivity: connect over Fast Ethernet through backbone switches, Security: Security enabled Wifi connectivity with option for Broadcast of SSID,Network:802.11 a/b/g/n network support, PoE: PoE enabled, Form factor: Wall or ceilling mountable with physical lock suppor. Warranty and support: 3 years on site comprehensive warranty including parts and labour plus on site technical support with 24 X 7 72 LAN TrainerEthernet (IEEE 802.3 wireless LAN (802.11),Token bus ( 802.4) Token ring ( 802.5), Data rate : 10/100 Mbps for ethernet, 1, 2, 5.5, 11 Mbps for wirless & LAN as per IEEE 802.11b, connectivity through RJ 45 connector. 73 Installation & commissioning of network(i) Laying ofOFC & CAT 6 Cable (ii) splicing (iii) Installation & network testing 74 INSTRUMENTATION AND CONTROL LAB (6th sem) 75 To measure displacement with LVDT ACTUAL LVDT WITHINSTRUMENTATION AMPLIFIERDC O/P WITH DIGITAL METER, 3and 1/2 digit LED display with polarity indicator, sensitivity of 10mV/mm in the range of 10mm. 76 To measure temperature with thermocoupleTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 77 To measure temperature with thermistorTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 78 To measure pressure with strain gauge STRAIN GAUGE SENSOR WITH WAIGHT LOADING SYSYTEM SAMPLE WEIGHTS.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR 79 To plot the Characteristics of RTD (PT-100)RTD 3 WAIR SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 80 Temperature controller with on-off controller, Temperature controller with PI controller, Temperature controller with PID controllerTemperature controller with facilities for P, I, D and relay control blocks, Operating temperature: Ambient to 90°C, Separate controls for P, I, D channel gains,Two settings for relay hysteresis, Fast 25W oven fitted with IC temperature sensor, Forced cooling option to ready oven for next experiment, Digital display of set and measured temperature on a 3½ digit built-in DVM, 0-9999 sec, timer on panel for a convenient temperature response experiment, Buffered output for recorder 81 CIRCUIT THEORY LAB 82 Determine the permeability of magnetic material by plotting its B-H curveHysteresis Loop Tracer/ BH Curve apparatus220volt AC, 50Hz supply 83 Series parallel resonance of R-L-C cktKit for Series parallel resonance of R-L-C ckt: The Set-up consist of Power supply (with variable frequency), audio oscillator with digital readout, digital RMS meters and different number of inductors (smoothly variable), capacitors, Rheostat, patch cord & manual. 84 SWITCH GEAR LAB 85 Speed control of Induction motor 1ph by using SCR3Φ, 400V ac, 50HZ.,1HP, 1440 rpm. Speed control using ac back to back configuration of SCRs and to note Speed vs. Load Characteristics at open loop condition. This unit should consist of AC 3Φ Induction Motor (1HP) coupled with a (i) DC Shunt Generator (1HP) for loading and (ii) a DC Tachogenerator to be used for speed feedback control. A DC meter must be provided for displaying the speed of the motor from the Tachogenerator with suitable AC Ammeter and Voltmeter for the measurement (AE Make Panel Type or digital) Sheet Metal enclosure with powder coating paint must be provided. (with foundation & Experiment Table) 86 C.T. & P.T. testing trainer kit C.T. & P.T.testing trainer kit - Variable AC voltage source (0-220V)& variable AC current source (0-25A), CT for 25/5A, PT for 220/110V, Autotransformer for voltage & current adjustment, MCB protection, To determine Ratio error, Phase angle error of CT & PT, with Burden box. , polarity check indicator , range selector switch. 87 Induction type electromagnetic relay* Over Current (IDMTL Electro- Mechanical Type , Model CDG-11 or equivalent) Relay,*PSM, TSM setting* Auxiliary Relay,* Counter /Timer,* D.W. Transformer, * Variac,* Knife Switch,* DC power supply for DC auxiliary relay and the relay,* Portable Ammeter.Necessary panel for the complete set up with wooden (teak wood) table (4x3x2.5) 88 Air Circuit BreakerCut section model 89 Transmission line protection simulation KitOver Current, Earth Fault, Over Voltage, Under Voltage, Directional, Differential, Distance protection 90 POWER PLANT LAB 91 Diesel generator power plantmodel of small diesel generator power plant 92 Hydro power plantmodel of micro Hydro power plant 93 Horizontal axis small wind turbinemodel 94 CSP plantmodel 95 MEASUREMENT LAB 96 Kelvin double bridgeCompletely self contained, stand alone unit with built in power supply, required meters, Standard Resistance, wooden bench, high sensitivity spot light type galvanometer, connecting patch chords and operating manuals. 97 RENEWABLE ENERGY LAB 98 Renewable Energy Labsolar PV plant- Model 99 Renewable Energy Labvertical axis small wind turbine- Model 100 ELECTRIC MACHINE LAB 101 VoltmeterVoltmeter (M.I type) 0-150V/300V/500V 102 VoltmeterVoltmeter (M.I type) 0-20V/50V 103 AmmeterAmmeter (M.I type) 0-5A/10A/20A 104 AmmeterAmmeter (M.I type) 0-1A/2A/5A 105 MultimeterAnalog Multi-meter of ISI marked: DC : 0-200 mV/ 1000 V & 0- 2mA – 10 A,AC : 0 – 200mV/1000V &0-2 mA – 20 A, Resistance : 0 – 200 Megaohm, with shock proof protection & other facilities and operatingmanuals. 106 MultimeterDigital Multi-meter of ISI marked: DC : 0-200 mV – 1000 V & 0-2mA – 10 A,AC : 0 – 1000 V & 0- 2mA– 20 A, Resistance : 0 – 200 Megaohm, with diodetesting, data hold, shock proof protection , auto power off etcfacilities and operating manuals. 107 WattmeterDynamometer Wattmeterof ISI marked : Low Power Factor ( 0.2 ) : Current Rating : 5/10 A , Voltage Rating : 150/300 / 600 V , with anti-parallax mirror , 120 mm scale length , knife edge pointer, mouldedBakelite body, portable. 108 VoltmeterVoltmeter (PMMC type) 0-150V/300V 109 AmmeterAmmeter (PMMC type) 0-2A/5A 110 StarterDC 3-point Starter : 220 V DC , 15 A 111 StarterDC 4-point Starter : 220 V DC , 15 A 112 DC Power SupplyDC Power Supply : Input : 415V, #-Phase AC, 50 Hz;Output : 220V DC , 5 KW of a standard make . 113 RheostatRheostat with sliding Jockey : 100 Ohm , 5 A 114 RheostatRheostat with sliding Jockey : 500 Ohm , 5 A 115 Digital Energy MeterDigital Energy Meter of ISI marked: Three Phase AC , 440 V , Maximum 30 A, 50 Hz with operatingmanual. 116 Digital MeggerDigital Megger for measuring insulation resistance of ISI marked: 250 / 500 V, Maximum 200 Mega ohmwith operating manual 117 VariacSingle Phase Variac of ISI marked : Input:– 230 V AC, Output : 0 – 270 V AC , 1 KVA, 50 Hzof a standard make 118 VariacThree Phase Variac of ISI marked : Input:– 415 V AC, Output : 0 – 500 V AC , 3 KVA, 50 Hzof a standard make 119 Clamp on MeterClamp on Meter of ISI marked : Digital type : For measuring Voltage ( AC/DC ), Current ( AC/DC ) , resistance, Power & Power Factor with operating manuals 120 Phase Sequence IndicatorPhase Sequence Indicator of ISI marked : 50 – 500 V AC, 25 – 60 Hz 121 Frequency MeterFrequency Meter of ISI marked: Digital Type : 240 V, 47 – 99 Hz 122 TransformerSingle-Phase Transformer : 1 KVA , 230 V/115V , 50 Hz( Air Cooled) 123 TransformerThree-Phase Transformer : 3 KVA , 415/230 V , 50 Hz 124 3-Ph Resistive LoadThree phase resistive load : 400 V , 6 KW 125 3-Ph Inductive LoadThree phase inductive load : 400 V , 3 KW 126 3-Ph Capacitive LoadThree phase capacitive load : 400 V , 3 KW 127 3-Ph StarterStar Delta automatic starter for 3 Phase,400 V, 5 Hpmotor 128 3-Ph DOL StarterDOL & Auto -Transformer Starter : 3-phase AC , 400V, 10A, 50 Hz 129 StroboscopeDigital Stroboscope - 10,000 rpm 130 DCGenerator Voltage build UPSupply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Building up Voltage in DC Generator ( Open Circuit / Saturation Characteristics: DC Shunt Motor of ISI marked : 2HP or 5HP, 220 V. Machines will have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and operating manual isalso must.(with foundation & Experiment Table) 131 Brake test in DC Series Motor Supply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , Spring balance & loadings, protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Brake test in DC Series Motor& load Characteristics: DC Series Motor of ISI marked : 2HP, 220 V.Machineswill have to be set on M.S.Channel base with suitable footing/ fixtures and screws etc. and operatingmanual is also must.(with foundation & Experiment Table) 132 Speed Controlof 3-Phase Squirrel cage Induction motorSupply, Installation , Commissioning & Testing with necessary & suitable ISI marked meters such as ammeter, voltmeter, frequency meter , starter, protective devices and all other accessories mounted on a standing panel board as per following specification :For Speed Controlof 3-Phase Squirrel cage Induction motorby – (i) volt /freq control method : Three phase Squirrel cage induction motor : 2HP, 400V with v/f controller.Machineswill have to be set on M.S.Channel base with suitablefooting/fixturesandscrewsetc.includingtheoperating manual.(with foundation & Experiment Table) 133 Load Test of an Alternator & % regulation at various loads with Unity Power factorSupply, Installation , Commissioning & Testing with suitable ISI marked ammeter, voltmeter, starter, star connected load , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Load Test of an Alternator and Determination of%-age regulation at various loads with unity power factor : DC Shunt Motor of ISI marked : 3HP, 220 V , AlternatorISI marked: 2 KVA, 415 V , 50 Hz.Machineswill have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and andoperating manual is also must.(with foundation & Experiment Table) 134 Measurement of Slip of 3-Phase induction motorSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter, stroboscope etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :Measurement of Slip of 3-Phase induction motor by –(i) Stroboscopic& (ii ) Tachometer methods and reversing the direction of rotation of the motor : Three phase squirrel cage induction motor of ISI marked: 2 HP , 415 V , 50 Hz .Machineswill have to be set on M.S.Channel base withsuitable footing/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 135 Synchronization of two 3-Phase alternatorsSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification : Synchronization of 3-Phase alternator ( 2 SETS ) by– (a) Three Lamp & (b) Synchroscope Methods : DC Shunt Motors of ISI marked : 5HP, 220 V ,Alternators of ISI marked: 3 KVA, 400 V, 50 Hz.Machineswill have to be set on M.S.Channel base withsuitable footings/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 136 POWER SYSTEM LAB 137 KIT FOR STUDY OF ACTIVE & REACTIVE POWERWITH SIMULATIOL KIT & LAPTOPStudy of Active & Reactive power with simulator Kit and Laptop with appropriate software, The kit should consist of variable Inductive & Capacitive load to observe change in active & Reactive power 138 MODEL OF VARIOUS TYPES OF TURBINES USED IN POWER GENERATING STATIONSModel Piece of each type of Turbine 139 PYRANOMETERMEASUREMENT OF SOLAR RADIATION BY PYRANOMETER 140 PHOTO VOLATIC SYSTEM USED IN STREET LIGHTWITH SOLAR PLATE,PV CELL,BATTERY,CHARGER 141 STUDY OF POWER SYSTEM OF 6.6 KV/400 V SUBSTATION USED FOR A HOUSING CONPLEXMODEL 142 D.C NETWORK ANALYSERD.C NETWORK ANALYSER FOR STUDY OF DIFFERENT TYPES OF FAULTS 143 DIFFERENT TYPE OF EXCITATIONS SYSTEM USED IN ALTERNATORSTATIC EXCITER,SHAFT MOUNTED,ROTATNG TYPE EXCITER & Brushless exciter ( Model only) 144 MISCELLANEOUS 145 MOTOR-ALTERNATOR SET FOR SYNCHRONISATION OF TWO ALTERNATOR WITH SYCHRONISING PANEL INCLUDING CHECK SYNCHROSCOPE & BULB ARRANGEMENT TO PERFORM TWO BRIGHT ONE DARK LAMP METHOD1.TWO SET OF D.C MOTOR 2.5 KW,230 VOLT,3000 R.P.M WITH SPEED CONTROL ARRANGEMENT 2. TWO SET OF 1 KVA,3 PHASE,440 VOLT,3000 R.P.M ALTERNATOR WITH BASE MOUNTING & EXCITATION SYSTEM. 146 PlierPlier of good quality 147 TesterTester Screwdriver of reputed brand 148 Screwdriver setScrewdriver set of reputed brand
Contract Date: Mar 12, 2026 Contract Value : 33.87 Lakh
Government Departments No of Bidders 9
West Bengal View Result →
24.
Public Administrative Department #9750812 AOC
Supply Of Computer And Related Essential Items As Per Requirement For Amalner Municipal Council For Year 2025-26 , Supply Of Computer And Related Essential Items As Per Requirement For Amalner Municipal Council For Year 2025-26 , All In One Desktop (Core I3 )( Ram8/16Gb )( Ssd 256Gb / 512Gb)( Led22inch) Windows 11 /Ms Office Made By -Lenovo , Hp , Acer , Dell , Asus , All In One Desktop (Core I5 )( Ram16gb )( Ssd 512))( Led22inch) Windows 11 /Ms Office Made By -Lenovo , Hp , Acer , Dell , Asus , All In One Desktop (Core I7 )( Ram16gb/32Gb )( Ssd 512)( Hdd 1Tb )( Led 24Inch/27Inch) Windows 11 / Ms Office Made By- Lenovo , Hp , Acer , Dell , Asus , All In One Desktop (Core I7 )( Ram 32Gb )( Ssd 512)( Hdd 1Tb )( Led 27Inch) Windows 11 / Ms Officemade By- Lenovo , Hp , Acer , Dell , Asus , Desktop (Core I3 )( Ram 8Gb )( Ssd /256Gb/512 )( Led 19Inch/22Inch) ( Keyboard Mouse) Windows 10 /Ms Officemade By-Assemble, Hp , Lenovo ,Dell , Acer , Asus , Desktop (Core I5)( Ram 16Gb/32Gb )( Ssd 256Gb/512 )(1Tb/2Tb )( Led 24Inch/27Inch )( Keyboard Mouse )Windows 11 /Ms Office , Made By-Assemble, Hp , Lenovo ,Dell , Acer , Asus , Desktop (Core I7 )( Ram 16Gb/32Gb )( Ssd 512 )( Hdd 1Tb/2Tb )( Led 19Inch/22Inch/24Inch/27Inch )( Keyboard Mouse ) Windows 11 /Ms Officemade By-Assemble, Hp , Lenovo ,Dell , Acer , Asus , Desktop (Core I7 )( Ram 8Gb/16Gb/32Gb )( Ssd 128/256Gb/512 )( Hdd 2Tb )( Led 27Inch )( Keyboard Mouse Wire/Wireless)Windows 11 /Ms Officemade By-Assemble, Hp , Lenovo ,Dell , Acer , Asus , Laptop - (Core I7 )( Ram 32Gb )( Ssd 512)( Hdd 1Tb )( Led 27Inch) Windows 11 / Ms Officemade By- Lenovo , Hp , Acer , Dell , Asus , Assemble Desktop Computer Set- (Core I5 With All Kit- 256Ssd, 1Tb Hdd, Mother Board,Cabinet With Smps, Wifi Adaptor, Keyboard & Mouse, 24 Monitor , Assemble Desktop Computer Set- (Core I7 With All Kit- 256Ssd, 1Tb Hdd, Mother Board,Cabinet With Smps, Wifi Adaptor, Keyboard & Mouse, Led 27 Monitor , Antivirus For One Pc One Year ( Pro , Internet Security , Total Security ) Providers - Net Protector , Quick Heal , Bitdefender , Vibranium , Antivirus For One Pc Three Year ( Pro , Internet Security , Total Security ) Providers -Net Protector , Quick Heal , Bitdefender , Vibranium , Pen Drive - 32 Gb, Type 2.0Made By- Sandisk , Evm , Acer , Hp , Pen Drive - 32 Gb, Type 3.0Made By- Sandisk , Evm , Acer , Hp , Pen Drive - 64 Gb, Type 3.0Made By- Sandisk , Evm , Acer , Hp , Pen Drive - 64 Gb, Type 3.2Made By- Sandisk , Evm , Acer , Hp , Pen Drive - 128 Gb, Type 3.2Made By- Sandisk , Evm , Acer , Hp , C Type Pen Drive - 32 Gb Made By Sandisk , Evm , Acer , Hp , C Type Pen Drive - 64 Gb Made By Sandisk , Evm , Acer , Hp , Keyboard - Made By- Hp , Dell , Acer , Frontech , Zebronic , Lenovo , Zebion, Tvs , Keyboard (Wireless)-Made By-Hp , Dell , Acer , Frontech , Zebronic , Lenovo , Zebion, Tvs , Mouse -Made By -Hp , Dell , Acer , Frontech , Zebronic , Lenovo , Zebion, Tvs , Mouse (Wireless) Made By - Hp , Dell , Acer , Frontech , Zebronic , Lenovo , Zebion, Tvs , Mouse Pad , Internal Hard Disc 1Tb(Company :- Seagate , Western Digital Wd , Toshiba) , Internal Hard Disc 2Tb (Company :- Seagate , Western Digital Wd , Toshiba) , Internal Hard Disc 3Tb(Company :- Seagate , Western Digital Wd , Toshiba) , Usb Hard Disc1tb (Company :- Seagate , Western Digital Wd , Toshiba) , Usb Hard Disk 1.5 Tb (Company :- Seagate , Western Digital Wd , Toshiba) , Usb Hard Disc 2Tb (Company :- Seagate , Western Digital Wd , Toshiba) , Usb Hard Disc 3Tb(Company :- Seagate , Western Digital Wd , Toshiba) , Usb Hard Disc 4Tb(Company :- Seagate , Western Digital Wd , Toshiba) , Usb 3.0 Hard Disk 1.5 Tb (Company :- Seagate , Western Digital Wd , Toshiba) , Usb 3.0 Hard Disc 2Tb (Company :- Seagate , Western Digital Wd , Toshiba) , Usb 3.0 Hard Disc 3Tb(Company :- Seagate , Western Digital Wd , Toshiba) , Usb 3.0 Hard Disc 4Tb(Company :- Seagate , Western Digital Wd , Toshiba) , External Hard Disk 3.5, 4Tb(Company :- Seagate , Western Digital Wd , Toshiba) , External Hard Disk 3.5, 8Tb(Company :- Seagate , Western Digital Wd , Toshiba) , External Hard Disk 3.5, 16Tb(Company :- Seagate , Western Digital Wd , Toshiba) , Ssd (Solid State Drive)128Gb Type - Sata, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Ssd (Solid State Drive)256Gb Type - Sata, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Ssd (Solid State Drive)512Gb Type - Sata, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Ssd (Solid State Drive)1Tb Type - Sata, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Ssd (Solid State Drive)2Tb Type - Sata, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Ssd (Solid State Drive)3Tb Type - Sata, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Ssd (Solid State Drive)128Gbtype - M.2Mvme, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Ssd (Solid State Drive)256Gbtype - M.2Mvme, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Ssd (Solid State Drive)512Gbtype - M.2Mvme, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Ssd (Solid State Drive)1Tbtype - M.2Mvme, Made By- Evm , Hikvision , Sandisk , Western Digital Wd , Crucial , Powerx , Flatbed Scanner Made By -Canon , Hp , Epson , Tvs, Brother , Portable Scanner Made By -Canon , Hp , Epson , Tvs, Brother , Document Scanner Made By -Canon , Hp , Epson , Tvs, Brother , Barcode Scannermade By -Canon , Hp , Epson , Tvs, Brother , Laser Printer(Only Printer) Made By-Brother , Canon , Hp , Epson , Laser All In One Printer (Wifi, Duplex, Network Connected)Made By-Brother , Canon , Hp , Epson , Colourprinter Made By-Brother , Canon , Hp , Epson , Konika , Ricoh , Colour All In Printer Made By-Brother , Canon , Hp , Epson , Konika , Ricoh , Laser Printer Made By-Brother , Canon , Hp , Epson , Konika , Ricoh , Stand By Ups 725Va Made By-Artis , Zebronic , Zebion , Frontech , , Portable Ups 725Va Made By-Artis , Zebronic , Zebion , Frontech , , Online Ups 10Kv Made By Apc, Champion, Utl,Powerx , Online Ups 15Kv Made By Apc, Champion, Utl,Powerx , Online Ups20kv Made By Apc, Champion, Utl,Powerx , Online Ups25kv Made By Apc, Champion, Utl,Powerx , Online Ups 30Kv Made By Apc, Champion, Utl,Powerx , Battery For Online Ups 65 Amp (1 Year Warranty Period) Exite,Microtec,Powercell , Battery For Online Ups100 Amp (1 Year Warranty Period)Exite,Microtec,Powercell , Battery For Online Ups 110 Amp (1 Year Warranty Period)Exite,Microtec,Powercell , Battery For Online Ups150 Amp (1 Year Warranty Period)Exite,Microtec,Powercell , Battery For Online Ups200 Amp (1 Year Warranty Period)Exite,Microtec,Powercell , Battery For Online Ups 220 Amp (1 Year Warranty Period)Exite,Microtec,Powercell , Stand By Ups 1000Va Made By-Artis , Zebronic , Zebion , Frontech , , Portable Ups 1000Vamade By-Artis , Zebronic , Zebion , Frontech , , Ups Batter 7.0/ 12 Made By- Artis , Zebronic , Zebion , Frontech , Ramddr-38Gb Made By-Samsung, Aarvex, Crucial, Hynix, Kingston, Evm , Ramddr-4 8Gb Made By-Samsung, Aarvex, Crucial, Hynix, Kingston, Evm , Ramddr-416Gb Made By-Samsung, Aarvex, Crucial, Hynix, Kingston, Evm , Ramddr-432Gb Made By-Samsung, Aarvex, Crucial, Hynix, Kingston, Evm , Ramddr-5 8Gbmade By-Samsung, Aarvex, Crucial, Hynix, Kingston, Evm , Ramddr-5 16Gb Made By-Samsung, Aarvex, Crucial, Hynix, Kingston, Evm , Ramddr-532Gb Made By-Samsung, Aarvex, Crucial, Hynix, Kingston, Evm , Server Ram 16 Gbmade By-Samsung, Aarvex, Crucial, Hynix, Kingston, Evm , Server Ram 32 Gbmade By-Samsung, Aarvex, Crucial, Hynix, Kingston, Evm , Smps Desktop450w , Smps Desktop500w , Smps Desktop650w , Smps Desktop750w , Smps Desktop1000w , Motherboard Cell -Cmos (Complementary Metal Oxide Semiconductor) Cell Battery , Power Cable 1.5M (For Use Of Desktop Or Laptop) , Power Cable 3.0M (For Use Of Desktop Or Laptop) , Power Cable 5.0M (For Use Of Desktop Or Laptop) , Vga/ Hdmi Cable 1.5M , Vga / Hdmi Cable 3.0M , Vga / Hdmi Cable 5.0M , Vga / Hdmi Cable 10.0M , Vga / Hdmi Cable 15.0M , Vga / Hdmi Cable 20.0M , Printer Cable Usb1.5M , Printer Cable Usb 3.0M , Printer Cable Usb 5.0M , Cable Converter Hdmi To Dp , Cable Converter Hdmi To Vga , Cable Converter Vga To Hdmi , Cable Converter Vga To Dp , Projector - Android, 4K,Hd, Led Made By- Epson, Zebronic, Benq, Lapcare , Projector Screen With Tripod , Retractable Projector Screen , Electric Projector Screen , Projector Stand - Floor Stand / Adjustable Ceiling Mount , Mini Speaker Made By- Artis, Jbl, Clarion, Zebronic, Philips , Portable Trolly Speaker 1000Wmade By- Artis, Jbl, Clarion, Zebronic, Philips , Rack 2U(For Use Of- Cctv, Server, Server Rack) , Rack 4U(For Use Of- Cctv, Server, Server Rack) , Rack 8U(For Use Of- Cctv, Server, Server Rack) , Rack18u(For Use Of- Cctv, Server, Server Rack) , Rack32u(For Use Of- Cctv, Server, Server Rack) , Wireless Wifi Router Made By- D-Link, Tp-Link, Zebronics, Powerx , Core / Fibre Routermade By- D-Link, Tp-Link, Zebronics, Powerx , Virtual Routermade By- D-Link, Tp-Link, Zebronics, Powerx , Vpn Router Made By- D-Link, Tp-Link, Zebronics, Powerx , Sim Routermade By- D-Link, Tp-Link, Zebronics, Powerx , Wifi Usb Adaptor2.0(4G / 5G Support) Made By- D-Link, Tp-Link, Zebronics, Powerx , Wifi Usb Adaptor3.0(4G Support) Made By- D-Link, Tp-Link, Zebronics, Powerx , Wifi Usb Adaptor5.0 ( 5G Support) Made By- D-Link, Tp-Link, Zebronics, Powerx , New Laser Tonner - 12A, 18A, 19A, 78A, 88A, 277A Made By- Cannon, Epson, Hp, Brother, Ami, Zebronic , New Laser Tonner - 110 Made By- Cannon, Epson, Hp, Brother, Ami, Zebronic , New Laser Tonner - Tn880, Tn1020, Tn2365, Made By- Cannon, Epson, Hp, Brother, Ami, Zebronic , New Laser Tonnerdr2365, Dr2465, Dr-B021 Made By- Cannon, Epson, Hp, Brother, Ami, Zebronic , New Laser Tonnercf283xmade By- Cannon, Epson, Hp, Brother, Ami, Zebronic , Colour Tonner Made By- Hp, Epson, Canon , Laser Tonner Refilling - 12A, 18A, 19A, 78A, 88A, 277A Made By- Cannon, Epson, Hp, Brother, Ami, Zebronic , Laser Tonner Refilling- 110 Made By- Canon, Epson, Hp, Brother, Ami, Zebronic , Laser Tonner Refilling-Tn880, Tn1020, Tn2365,Made By- Canon, Epson, Hp, Brother, Ami, Zebronic , Laser Tonner Refilling-Dr2365, Dr2465, Dr-B021 Made By- Canon, Epson, Hp, Brother, Ami, Zebronic , Laser Tonner Refilling-Cf283xmade By- Canon, Epson, Hp, Brother, Ami, Zebronic , Colour Tonner Refilling Epson - 001,003, 057, 664, 673 , Colour Tonner Refillingcanon- 70,71,73 , Colour Tonner Refilling Brother- Bt5000, Btd60bk , Tonner Drum :- 12A , 88A , 78A , 19A , 110 , 277A , Tn880 , 18A , Tn1020 , Dr2465 , Tn2365 , Dr-B021 , Cf283x , Tonner Rolar :- 12A , 88A , 78A , 19A , 110 , 277A , Tn880 , 18A , Tn1020 , Dr2465 , Tn2365 , Dr-B021 , Cf283x , Tonner Magnet :- 12A , 88A , 78A , 19A , 110 , 277A , Tn880 , 18A , Tn1020 , Dr2465 , Tn2365 , Dr-B021 , Cf283x , Tonner Gear :- 12A , 88A , 78A , 19A , 110 , 277A , Tn880 , 18A , Tn1020 , Dr2465 , Tn2365 , Dr-B021 , Cf283x , Tonner Pcr :- 12A , 88A , 78A , 19A , 110 , 277A , Tn880 , 18A , Tn1020 , Dr2465 , Tn2365 , Dr-B021 , Cf283x , Tonner Blade :- 12A , 88A , 78A , 19A , 110 , 277A , Tn880 , 18A , Tn1020 , Dr2465 , Tn2365 , Dr-B021 , Cf283x , Drum Unit Kit For Brother Make Printer , New Tonner For Canon Make Digital Multi-Function Device Model Ir- 2224Ndd , Yearly Service & Maintaince For Canon Make Digital Multi-Function Device Model Ir- 2224Ndd , Voltage Stabiliser For Copier / Xerox Unit Capcity Capacity : 2 Kva , Single Phase. Input : 170-270. Output : 110V. , Computer / Laptop Usewebcams Specification -1080P, 4K,Hd,Use For Online Streamingmade By- Logitech, Lenovo, Dell,Zebronics,Hp , Computer Maintaince For 1 Year With All Material , Projector On Rent Per Day , Currency Counting Machine (Table Top Model) With Fake Note Detection Made By- Godrej, Phoenix, Unitech , Currency Counting Machine (Desktop Model) With Fake Note Detection Made By- Godrej, Phoenix, Unitech , Currency Counting Machine (Floor Model)Made By- Godrej, Phoenix, Unitech , Net Working On Rent Per Day , Cctv Camera :- Hd Cameramade By -Value , Cp Plus , Securus , Dahua , Hikvision , Trueviwe , Cctv Camera :- Ip Cameramade By -Value , Cp Plus , Securus , Dahua , Hikvision , Trueviwe , Cctv Camera :- Sim Camera Made By -Value , Cp Plus , Securus , Dahua , Hikvision , Trueviwe , Cctv Camera :- 360 Camera Made By -Value , Cp Plus , Securus , Dahua , Hikvision , Trueviwe , Cctv Camera :-360 Camera With Solarmade By -Value , Cp Plus , Securus , Dahua , Hikvision , Trueviwe , Dvr (For Hd Camera) :- 8Chmade By -Cp-Plus , Hikvision , Dahua , Securus , Dvr (For Hd Camera) :- 16Chmade By -Cp-Plus , Hikvision , Dahua , Securus , Dvr (For Hd Camera) :- 32Chmade By -Cp-Plus , Hikvision , Dahua , Securus , Nvr 4Ch Made By -Cp-Plus , Hikvision , Dahua , Securus , Nvr 8Ch Made By -Cp-Plus , Hikvision , Dahua , Securus , Nvr 16Ch Made By -Cp-Plus , Hikvision , Dahua , Securus , Nvr 32Ch Made By -Cp-Plus , Hikvision , Dahua , Securus , Cat6cable For Lan Indoor (Pure Copper) , Cat6cable For Lanoutdoor (Single Jacket) , Arbod Cable , Ac Adaptor For All In One Pc/ Laptop Usb Type60/80/100/120 Watt , Ac Adaptor For All In One Pc/ Laptop Round Type60/80/100/120 Watt , Ac Adaptor For All In Pc / Laptop Conventional Type60/80/100/120 Watt , Usb Hub 4 Portmade By - D-Link, Mercusys, Cisco , Usb Hub 8 Portmade By - D-Link, Mercusys, Cisco , Switch 16 Port Made By - D-Link, Mercusys, Cisco , Switch 24 Port Made By - D-Link, Mercusys, Cisco , Switch 32 Port Made By - D-Link, Mercusys, Cisco , Wifi Usb Adaptor , Motherboard 61Made By- Powerx, Zebion, Zebronix, Asur, , Motherboard81made By- Powerx, Zebion, Zebronix, Asur, , Motherboard 110Made By- Powerx, Zebion, Zebronix, Asur, , Motherboard 310Made By- Powerx, Zebion, Zebronix, Asur, , Led Monitor19 Made By - Hp, Lenovo, Acer, Asus, Dell, Powerx, Frontec, Zebion , Led Monitor21 Made By - Hp, Lenovo, Acer, Asus, Dell, Powerx, Frontec, Zebion , Led Monitor24 Made By - Hp, Lenovo, Acer, Asus, Dell, Powerx, Frontec, Zebion , Led Monitor27 Made By - Hp, Lenovo, Acer, Asus, Dell, Powerx, Frontec, Zebion , Led Tv- Hd, 4K 48 Made By - Mi, Samsung, Sony , For Pc / Laptop Extension Box For Electric Supply (07Mtr)Made By- Rr , Leo, Max, Matrix
Contract Date: Mar 09, 2026 Contract Value : 9.48 Lakh
Local Bodies No of Bidders 2
Maharashtra View Result →
25.
Defence #9749510 AOC
Tender For Construction Of Offer Md Accommodation At Island Ground Offers Enclave Chennai; 1 Lumpsum price worked out by the tenderer for BUILDINGS AND STRUCTURES as listed in Schedule ‘A’ Part-I 2 Lumpsum price worked out by the tenderer for SITE CLEARANCE/ AREA DEVELOPMENT as listed in Schedule ‘A’ Part-II 3 Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III 4 Lumpsum price worked out by the tenderer for INTERNAL ELECTRICSUPPLY & PVC CONDUIT as listed in Schedule ‘A’ Part-IV 5 Lumpsum price worked out by the tenderer forROAD/ PATH/ HARDSTANDING /CULVERTas listed in Schedule ‘A’ Part-V 6 Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI 7 Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII 8 Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VIII 9 Lumpsum price worked out by the tenderer forEXTERNAL ELECTRIC SUPPLY as listed inSchedule ‘A’ Part-IX 10 Lumpsum price worked out by the tenderer forLIGHTNING PROTECTIONas listed in Schedule ‘A’ Part-X 11 Lumpsum price worked out by the tenderer for FIRE FIGHTING/ FIRE ALARM AND DETECTION as listed in Schedule ‘A’ Part-XI 12 Lumpsum price worked out by the tenderer for LIFT as listed in Schedule ‘A’ Part-XII 13 SCHEDULE A PART XIII (MISCELLANEOUS ITEMS)Note: This schedule is not pre-priced by MES 14 INTERNAL WATER SUPPLY 15 S&F for 15mm dia bore 2 way bib tap/cock fancy type, cast copper alloy chromium plated, with crutch or butterfly handle one way suitable for fixing health faucet and other for bip tap, screwed for iorn pipe or ferrule complete all as specified and directed. 16 S&F for 15mm dia bore, brass CP mixer valve 2 in 1 hot and cold water including connected with shower rose, screwed for iorn pipe or ferrule, complete all as specified and directed. 17 INTERNAL ELECTRIC SUPPLY /PVC CONDUIT 18 M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor confirming to IS-694 1990 wih ISI marked (for phase, neutral and earth) in and including stove enamelled Steel conduit with ISI Mark of minimum 20mm dia and all conduit accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed glvanised steel pressed terminal boxes alongwith suitable size modular cover plates with frames for fixing modular switches and sockets, fan regulators etc. of suiable size modules and the earth wire to be connected to common earth dolly complete all as specified and directed for the following :- Note: Location of light points, 6 Amp socket points and light fittings may be decided by Engr-in-charge as per site/user requirment 19 One light point controlled by one modular switch 6A one way 20 One Ceiling/Exhaust fan point controlled by one modular switch 6A 21 One 3 pin socket out let6 Amps on independent board 22 One 3 pin socket out let 6 A on same board 23 One light point controlled by two 2-way switch 24 One bell/buzzer point controlled by one bell push 25 M&L for Point wiring complete all a specified with 1100 Volts grade 4 sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS 694 1990 with ISI marked (for phase, neutral and earth)in and includingstove enamelled Steel conduit ISI Mark of minimum size 20mm dia all accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed galvanised steel pressed terminal boxes for fixing modular sockets of suitable sizemodules and the earth wire to be connected to common earty dolly all as specified and as directed.all as specified and as directed for One three pin modular switch socket 16 amps outlet on independent board 26 S&F modular bell switch suitable type AC 240V, 6 Amps complete all as specified and directed by Engineer-in-charge. 27 Supply and Fix Modular switches suitable for type AC 240V ,6 amps 1 Module 2 way complete all as specified and directed by Engineer-in-charge. 28 Supply and Fix call bell of multi music type AC 230 volts completeall as specified and directed by Engineer-in-charge. 29 Supply and Fix wall mounted fan of double string, steel body AC single phase, 230v of size 400mm sweep with, blades frame, louvers, oscillation control knob, tilting control white colour (body and blades) complete all as specified and directed 30 Supply and Fix decorative wall light fitiing made up of polycarbonate suitable for 9 Watts Retrofit LED LampB22 Base complete all as specified and directed 31 S&F reading light (Bed Side) wall mounting5/7 W Cool day light CCT of 3000K 400Lumen output complete all as specified and directed make PhilipsCat No 31437 or equivalent in Havells or Wipro 32 ROAD/PATH /HARDSTANDING/ CULVERT 33 M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines,edge lines ,stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. 34 EXTERNAL WATER SUPPLY 35 Supply ,install , test and commission of Centrifugal electrically driven self priming monoblock pump set with cast iron impeller capable of pumping 350 LPM at 36 Mtr head, squirrel cage TEFC induction motor3 phase, 415V AC,50 Hz suitable for delivery 350 LPM at 36 Mtr head coupled on common base chanel including necessary PCC foundation works, nuts and bolts, copper cable from starter to motor through PVC rigid pipe ,suitable size of suction pipe not less than 20 feet or as reqd at site, Air release valve complete all as directed and specified 36 Supply and Fix Foot Valve normax type including fixingas per IS4038 all as specified and directed 65 mm DiaMake :Kirloskar,Zoloto,L&T 37 Supply, install, test and commission LT feeder piller box/ Panel board IEC -614391 , CPRI approved,indoor type IP-43 , vermin proof, dust proof , fabricated with 2 mm CRCA sheet mounted on 40x40x4mm MS angle, 3 phase 4 wire , 440 volts , AC , 50hz with TPN aluminiumbusbar of capacity100 amps with pvc insulator heat shrink colour code sleeves , mounted on procelin insulators duly prewiredcomplete volt and amp meter , selector switch with all accessories and consists of the following switch gears :-(a) Bus bar chamber with electrolytic aluminium bus bar 100 Amp capacity for 3 phase - 01 set(b) MCCB 4 pole adjustable thermal/magnetic setting ,63A, 415 V ,25 KA- 01 Nos (c) MCCB 4 pole ,32A, 415 V ,10 KA- 02 Nos (Lift & Fire Pumps)(d) MCBTP ,32A, 415 V ,10 KA- 02 Nos (Pump Sets)(f) Supply and fixing DOL starter suitable for pumping set- 02 Nos 5 HP(g) MCB SPN 6-32 Amp 10 KA -01 Nos(Pump House)(h) Digital voltmeter, Ammeter,LED phase indicator lamp, selectror switch(i) Single phase preventer- 02 Nos (j) MCB SP 32 Amps 16 KA- 1 No, Street Light Timer digital type-01 No. 38 M&L for construction of valve chamber 450x450x450 mm depth with PCC foundation in the ration 1:4:8 brick work cement mortar in the ratio 1:6 using of class B bricks , PCC coaping at the top of the ratio 1:3:6 , plastering 15 mm thick in the ratio 1:4 including MSsheet cover 3mm thick with angle iron frame 50x50x6mm locking arrengement complete with painting on steel surface with one coat of red oxide paint over two coats of synthetic enameeled paint all as specified and directed . (Earthwork shall be measured and paid seperetely in the respective items) 39 Supply and Fix Stainer Y type made of cast iron body flanged type completely fixed to line including all necessary bolts Nuts washers Etc of size 50 mm Dia Make :Kirloskar,Zoloto,L&T 40 Supply only chlorine test kitof reputed Make for testing water chlorine with all fittments and OT solution complete 41 Supply only synthetic rubber insulatedmat 2 mm thickfor voltage upto3.3 KV as per IS 15652-2006 of Size 1 meter x 2 meter x 19 mm 42 Supply testing and installation of Bleaching Dozer Bucket Type capacity 145 Litres FRP type with all fittings and fioxtures Orifice plate Drain Valve,solution dozing line (PVC) dose cantrol Valve ,Water inlet valve, air Valve any other accessories or pipe line of size upto 25 mm are included in the quoted rates all as specified and directed and supplyCHLORINE TEST KIT 43 EXTERNAL ELECTRIC SUPPLY 44 Earthing with galvanised steel earth plate electrode 60 cm x 60 cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part I 1991, GI earth lead protected by GI pipe 15 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt up to 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI light grade watering pipe, earth test point terminal block, commissioning & testing complete. ( Note :Main earth lead beyond 7.5 metre measured and paid for separately.) 45 M/L for LT cable route indicators Oval Shaped 200x150x6 mm cast Iron precastwith engraving LT MES CABLE embedded with PCC in mix 1:3:6 type C1 incl necessary exc, returning filling & removal of soil complete as directed. 46 .Supply and fix FRP pole box of size 168X253x115mm ,thermoplastic,polycabonate,IP-66 complete with 4 pole 32 A connector, Double compression glands-2 Nos, MCB SP 6 Amps mounted with GI clamps of suitable size with nuts and bolts on street light pole all as specified 47 Material and labour for street light bracket made of 40mm GI pipe light grade 1.5 m length bent in shape for mounting street light on one end, fixing the bracket on pole with suitable GI clamps, Nus and bolts all as specified and as directed.. 48 Fabricate, supply , install, test and commission LT feeder pilar box/panle board, outdoor type, fabricated with 3.15mm CRCA sheet mounted on 50x50x6mm MS angle, 3 phase 4 wire, 440v, AC, 50 Hz, with TPN aluminium bus bar of capacity 400 Amps with pvc heat shrink colour code sleeves, mounted on porcelin insulators complete volt and amp meter , selectro switch with all accessories and consist of the following switch gear: -( Main LTpanelatPGEPT & TA ) (i) Aluminium bus bar 3 phase & neutral of capacity 300 Amps(ii) MCCB 4 Pole 200 Amps 36 KA-01 No ( Incoming) (iii) MCCB 4 Pole 160 Amps 25 KA-02 No(iv) LED phase indication lamp for 3 phase-01 No 49 Fabricate, supply , install, test and commission LT feeder pilar box/panle board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50x50x6mm MS angle, 3 phase 4 wire, 440v, AC, 50 Hz, with TPN aluminium bus bar of capacity 400 Amps with pvc heat shrink colour code sleeves, mounted on porcelin insulators complete volt and amp meter , selectro switch with all accessories and consist of the following switch gear: -( Main LTpanel at Tower 1 ) (i) Aluminium bus bar 3 phase & neutral of capacity 300 Amps(ii) MCCB 4 Pole 160 Amps 36 KA-01 No ( Incoming) (iii) MCCB 4 Pole 100 Amps 25 KA-05 No (FF,SF,TF,FF& Pump House) (iv) MCCB 4 Pole32 Amps 16 KA- 2 No ( Ground Floor & Spare)(ix) LED phase indication lamp for 3 phase-01 No 50 Supply only synthetic rubber insulatedmat 2mm thickfor voltage upto 3.3 KV asper IS 15652-2006 of Size 1 meter x 2 meter x 19 mm 51 Provision of trenchless bore using mechanical pneumatic drilling equipment for passing electric cables through HDPE pipe of 100mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications all as specified and directed by engr-in-charge at site. Note : 1. Quoted rates deems to be inclusing of necessary earth work, transportation charges of Drilling machine, and cost of HDPE pipe and passing pipe through bore complete.2. Any damage to MES/Civil assets caused during trenchless bore shall be recitfied by the contractor at his own cost.Note:The rates are inclusive for obtaining necessary permission from state/Highway authorities and any other clearances as required before starting the work 52 FIRE FIGHTING SYSTEM/ FIRE ALARAM AND DETECTION 53 Supply, installation, testing, and commissioning of Fully automatic Star Delta Starter starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed 54 M & L for fire survival cable of size 3 core 16 sq mm with strandedannaealed bare copper conductor, mica tape wrapped for heat resistance up to 950deg centigrade, GI strip wire armouredand zero halaogen outersheathed XLPE insulation cable all as directed. Make: Havells/ KEI/ RR Kabel 55 M & L for PN 1.6 rated 100 mm NB polypropelene vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed 56 M & L for PN 1.6 rated 100 mm NB CI Y -type strainer for suction conforming to IS 907: 1984 & (Reaffirmed 2020) with SS filter screen and flange drilling standard end connection conforming to IS 1538: 2018 and necessary accessories for suction side of fire pumps complete all as specified and directed.(at pump suciton header). 57 M & L for earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized strip of size 32 mm X 6 mm as earth lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel, galvanized iron pipe of 40 mm diameter connected to earthing test point, all as shown in electrical plate No. 5, connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a 10 mm deep CI cover hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete all as specified and directed by the engineer-in-charge 58 M & L for Two wire addressable speaker with LED light flash/Beacon suitable for targeted announcements and equipped with a LED light flash ( to cater to hearing-impaired occupants). The unit shall be equipped with an LED that blinks in normal conditions and glows steadily upon activation. Both the control panel and speaker unit shall continuously scan for healthiness and cable connectivity to ensure integrity compliance. the speaker must have a minimum capacity of 5 watts with max voice current of 100mA. It shall have ABS housing along with Back box. it shall be able to produce 90 dB sound at 1 Mtr distance 59 M & L for remote repeater panel similar to main control panel capable of full supervision of all inputs an network integrity, having colour touch screen display, environmental adjustment control to maximise LCD legibility, LED status indicator. ( For power supply and OFF normal conditions) 60 M & L for low smoke zero halogen(LSOH) flame retardant fire alarm cable 2C x 1.5 Sqmm conforming to BS-7629-1, BS-6387 and BS EN 50200 and rated for 500V drawn through and including concealed PVC conduit and accessories of min 20mm dia NB and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicon rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheathed conforming to BS 7655, suitable for operating temp -30 deg centigrade to +70 deg centigrade and min bending radius being six time the overall cable diameter, red in colour, including laying termination and ferruling complete all as specified and as directed 61 M&L for Firemans switch and Interconnecting with LV Switch The cost of any balance item to make MOEFA system installed under Sch A part XI above is deemed to be included in the quoted rates so as to make the system complete and fully functional ass per the prevailing engineering. 62 Supply and fixingof Mechanical foam type fire extinguishers, 9 Ltr capacity, IS:15683 : 2006, complete. 63 Supply and fixingof Dry powder ABCstoredpressuresqueezegriptypefire extinguishers, 9 kg capacity, IS:15683 : 2006, filled with ABC Mono AmmoniumPhosphatebasepowder-90completewithdischarge hose and wall mounting bracket, 2mm Mild Steel, EPDM Rubbers, Pressure Guage, which work effectively on allclass of fires (A, B, C & Electrical fires)complete. 64 Supply & fixing of 4 Nos of 9 lts capacityround bottom sand /water buckets along with round bottom type , enamel painted white inside and red outside& letter fire in black outside & handle with mounting bracket along with suitable MS stand to install the buckets as per the local fire standards 65 LIFT 66 Earthing with galvanised steel earth plate electrode 60 cm x 60 cm x3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead Copper strip 20 mmx3mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part I 1991, GI earth lead protected by GI pipe 40 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt upto 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI light grade watering pipe, earth test point terminal block, commissioning & testing complete. Note :Main earth lead beyond 7.5 metre measured and paid for separately.) 67 ELECTRIC CHIMNEY 68 Supply Install Testing and comissioning of Electric Chimney of size, Filterless Wall Mounted type,Operating Voltage 220 Volts 50 Hz with ,Auto Clean 3 speed cantrol gesture with 2X 1,5 LED and all other necessary fittingsand fixtures required complete all as specified and directed.Supply, erection & testing of electricalchimney with the following specificationsSize: 90 cmShape / mounting: Box / wall mountingSuction capacity : 1500-1800 cum/hrAir outlet size: 150 mmDuct size : 150 mm Duct :MOC- Stainless Steel,Duct pipe/baffle filter: inclusive as required.Motor type: BLDC motor, 240W.Blower type: MetallicLamp: 2 x 1.5 WFinish: Stainless SteelFeatures: Low Noise (less than 62 dB) steam auto cleanControls: Dual touch, multi speed option, motion sensor”.Make: Faber/ Hindware/Glen /Kaff/Cropmton 69 DG SET 70 Supply, installation, testing and commissioning of 40 KVA / 32 KW,(The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of40 KVA or equivalent, developing 1500 RPM, Water Cooled, electric start coupled toEquivalentalternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters,with emission control device as per CPCB IV + Norms and updated till date on procurement and CPCB approved acoustic enclosure suitable for ambient condition atChennai with integral fuel tank with battery and leads and accessories complete including required PCC foundation as per manufacturers instruction and confirming to conditions as per IS provisions:- 71 (A) Alternator :- Standard design alternator rated at 40 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class H and voltage regulation of ± 1 % at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in ± 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS/IS – 4722 and as per the following provisions:- Make:- KIRLOSKAR/JYOTI / STAMFORD/CATERPILLAR(a) Insulation class - H(b) Temperature rise Class - H(c) Excitation: Self Excited(d) Regulation performance: The voltage is kept constant with ± 1 %, manual voltage adjustment within ± 5%(e) Frequency regulation ± 1 %(f) 2 runs of UG cable of suitable size from Alternator to AMP is deemed to be include in quoted rate. 72 (B) Diesel Engine: - Adequate capacity Diesel engine suitable for 40 KVA coupled drive independently above alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all asspecified and required for safe handling and operation salient features of accessories shall be as under Make :- KIRLOSKAR/CUMMINS / CATERPILLAR (GEMCO) 73 (a) Fly wheel with housing (b) Cooling system :- Mounted radiator with fan & belts.(c) Cooling pump: - Centrifugal type belt driven. (d) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacture standard with MS pipe light grade up to and away two meters height from top of enclosure including necessary angle iron frame supports from floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50mm rapped with chicken wire mesh of size 2.25mm and aluminum sheet of 24 SWG to be complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type Exhaust manifold Silencer: Residential type Belows 74 (C) Fuel System :- Fuel injection system with fuel injectors, fuel injectionsolenoid switch/nozzles/ governor mechanical type capable for 1 % speed/frequency regulation.(i) Fuel filters(ii) Fuel hoses(iii) Lub oil System :-(iv)Lubricating oil filter(v) Lubricating oil pump(vi) Air Intake System :-(a) Air intake Manifold(b) Air cleaner dry type(a) Starting System :- Electric Self starter with maintenance free batteries including battery charging alternator.(b) Batteries:- 1 No. Maintenance free Battery of suitable AH capacity complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified.Make:- EXIDE / AMRON / Produced by original DG set manufacturers 75 (i) Starter gear ring(ii) Start and stop push button(iii) Ignition key / Switch(iv) Handling and operation: Salient features of accessories shall be asunder:(a) Radiator with blower fan(b) Corrosion inhibitor coolant(c) Paper element filters for fuel, lub oil and by pass.(d) Governor controlled direct fuel injection system(e) Fly wheel housing and fly wheel. 76 (D) Generator Monitoring Panel: Comprising of following:-(a) Microprocessor based integrator generator set monitories, metering,protection and control system with built torque matched volts/H3 over load control.(b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown)(c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down)(d) Relay drivers for remote annunciations(e) Cyclic cranking(f) Auto/manual start stop(g) Alternator trim adjustment from the front key pad(h) Operates within a temperature range 0- 50°C and humidity up to 95%(J) Remote monitoring capability through separate interface modulesk) Genset metering parameters like lube oil pressure, coolant temperature, engine speed(rpm), run hours, DC voltage, 3 phase volts and 3 phase amperes, frequency, KW, KVA, power factor 77 (l) Safety Controls : - Engine low lube oil pressure, high water temperature and over speeding of engine.(m) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling fly wheel housing.(n) Accessories :-A VM Pads built or separately mounted to manufacturer base frames.(o) Base Frame: - Made out of ISMC 200 of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (p) Fuel Tank :- Daily service fuel tank of capacity minimum 08 hrs running storage (Inbuilt) made out of 3mm thick (Heat Retardant) sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be installed with in built inside the acoustic enclosure is inclusive of the cost of DG Set and is as per manufacturer design.(q) Deliverables:- Confirms the norms established by CPCB. 78 (E) AMF PANEL:-(a) Auto Main Failure (AMF) panel made out of 2 mm thick CRCA sheet, powder coated of conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase,4 Wire, AC 50 Hz having aluminum bus bar capacity required to carry current at 100% load of 40 KVA DG set with three phase and half neutral color coded, prewired with copper flexible cable, be all as specified with the following accessories, control cable from Gen set to AMF panel: (i) 63 Amps, 4 pole contactor - 2 Nos.(ii) MCCB, 4 Pole 63 Amps, 25 KA-2 Nos for both supplies suitable fuse links.(iv) CTs 50/5A for both the supplies.(v) DC Ammeter.(vi) DC Voltmeter.(vii) Push buttons.(viii) Indication Lamps.(ix) 2 over load+ earth leakage relay. 79 (x) Multi functional digital meter for KWH,KVA,KW,Amps,volts, frequency,power factor etc.(xi) SMPS Battery charger 12V, with trickle & Boost charging(xii) On/ Off switch.(xiii) Automatic/manual switch.(xiv) Hooter.(xv) Voltage sensing relay.(xvi) Six window enunciator for fault indications.(xvii) Electro magnetic relays.(xviii) Metering required in DG set :- A, V, Hz, KVA, KW, PF & KWH Metering required in mains :- A, V, Hz. 80 (F) Acoustic enclosure: CPCB approved enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:-(a) Custom built product for various equipments, with ensure the optimum performance without duration. 81 (b) Rugged in construction maintenance free and modular designs which facilitate easy at site.(c) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets.(d) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against eathering action.(e) Special paint treatment with pure polyester 82 powder/epoxy to be provided for better weather resistance.(f) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently.(g) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used.(h) Working space is to be provided around tube equipment for easy maintenance / repairs.(j) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement.(k) A see through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation.(l) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided.(m) Deliverables. 75 dBA @ 1 mtr at 75% load under free field conditions. The temp inside tee enclosure will be within as per manufacturers recommendations above ambient temp. 83 (n)The enclosure should be provided with bulk head light fitting for inside illumination(o) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform.(p) The DG Set should be provided with external Emergency stop push button.(q) The acoustic enclosure parts shall be of powder coated after pre treatment process.(r) The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade. 84 Make for AMF PANEL: DG SET OEMMake for ACCOUSTIC PANEL: DG SET OEMThe following provisions are deemed to be included in the rate quoted forDG set:-(a) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil and final successful acceptance test.(b) DHPP for testing purpose shall be supplied by the contractor without any extra cost to department.(c) The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. 85 (c) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of one hour on 10% overload in presence of representative detailed by accepting Officer, all arrangements are to be made by thecontractor for tests.(d) Rate quoted shall be deemed to be included in making necessary holes to walls and making good the disturbed surfaces to match to original specification and connecting up all as specified and directed . 86 (G) Civil Works :- All civil works with PCC plat form and related tofoundations including of panel and equipments and making good theexisting structure of disturbed during installation and commissioning ofGenset. The depth of the foundation shall be minimum 300 mm with ant vibration pads or as recommended by the manufacturer. 87 M & L earthing complete with galvanised steel earth plate electrode 60cmx 60cmx 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts,check nuts and washer etc. of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test pointincl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4)and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. 88 Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate. 89 PILE FOUNDATION,PILE CAP AND GRADE BEAM 90 450mm diaBoring for Bored cast in situ piles 16 metres in soil and getting out and disposal ofspoil to a distance out side MD Land using DMC method (Direct mud circulation) through rig mechine complete all as specified and directed. 91 500mm diaBoring for Bored cast in situ piles 16 metres in soil and getting out and disposal ofspoil to a distance out side MD Land using DMC method (Direct mud circulation) through rig mechine complete all as specified and directed. 92 Add/Deduct to above item No -58 450mm bore caste in situ piles for each metrecomplete all as specified and directed. 93 Add/Deduct to above item No -59500mm bore caste in situ piles for each metre complete all as specified and directed. 94 450mm diaBoring for Bored cast in situ pilesin Chiselling / cutting through for boring for cast in situ piles through rig mechine in soft rock and getting out and disposal of spoil to a distance out side MD Landcomplete all as specified and directed. 95 500mm diaBoring for Bored cast in situ pilesin Chiselling / cutting through for boring for cast in situ piles through rig mechine in soft rock and getting out and disposal of spoil to a distance out side MD Landcomplete all as specified and directed. 96 450mm diaBoring for Bored cast in situ pilesin Chiselling / diamond cutting through for boring for cast in situ piles through rig mechine in hard rock and getting out and disposal of spoil to a distance out side MD Land complete all as specified and directed. 97 500mm diaBoring for Bored cast in situ pilesin Chiselling / diamond cutting through for boring for cast in situ piles through rig mechine in hard rock and getting out and disposal of spoil to a distance out side MD Land complete all as specified and directed. 98 S&F TMT 10 mm and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed)not less than 0.9 mm dia conformig to Fe 500D CRS. and guide ring will be welded with main barscomplete all as specified and directed. 99 All as per item no above herein before but 6 mm dia and over upto including 10 mm dia in stirrups, spacersand binders. 100 M & L for design Mix RMC M-30 RCC inpile foundations as per derived depth complete all as specified and directed. 101 Complete Chiseling M-30 design mix concrete pile of dia 450mm of depth as required at site and removal complete all as specified and directed. 102 Chiseling M-30 design mix concrete pile of dia 500mm of depth as required at site and removal complete all as specified and directed. 103 The following Carrying out Initial Load Test on 450/500/600 mm dia. bored cast-in-situ piles as per IS-2911 (Part-IV) complete all as specified and as directed. 104 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 450mm dia pile. complete all as specified and directed 105 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 106 Lateral load test,as per IS-2911 (Part-IV) for 450mm dia pile .complete all as specified and directed 107 Lateral load test,as per IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 108 Carrying out Routine Load Test on 450/500/600mm dia. bored cast-in-situ piles as per IS-2911 (Part-IV) complete all as specified and as directed. 109 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 450mm dia pile.complete all as specified and directed 110 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 111 Lateral load test,as per IS-2911 (Part-IV) for 450mm dia pile.complete all as specified and directed 112 Lateral load test,as per IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 113 Integrate Test for all Routine piles .complete all as specified and directed 114 Excavating over areas in soft /loose soil, n exc 1.5 m deep and getting out complete all as specified and directed. 115 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 116 M&L for Plain Cement concrete Type B2 1:2:4 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. 117 M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. 118 M & L for design Mix RMC M-30 RCCas inpile cap complete all as specified and directed. 119 S & F MS liner for piles of any size using MS sheet of any thickness all as directed by Engineer in charge. 120 M&L for Formwork to sides of concrete foundations, footings, Pile cap, grade beams bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Contract Date: Mar 06, 2026 Contract Value : 10.17 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
26.
Health and Family Welfare #9675359 Technical Bid
Tender For supply of Drugs, Medicine And Consumable And Other Iteam For One Year Rate Contract At Cmho Banswara , List Of Drugs , Lignocaine Gel Ip 2% , Lignocaine Injection 2% , Lignocaine And Adrenaline Injection 20Mg + 0.01Mg , Lignocaine And Dextrose Injection 50Mg + 75Mg Per Ml , Bupivacaine Hydrochloride In Dextrose Injection 5Mg + 80 Mg Per Ml , Bupivacaine Injection 0.50% , Atropine Sulphate Injection 0.6 Mg/Ml , Midazolam Injection Ip 1 Mg/Ml , Tramadol Capsule 50 Mg , Tramadol Injection 50 Mg/Ml , Pentazocine Injection 30 Mg/Ml , Aspirin Tablet Ip (Gastro-Resistant) 150 Mg , Aceclofenac And Paracetamol Tablet 100 Mg + 500 Mg , Diclofenac Gel: Diclofenac Diethylamine , Methyl Salicylate , Linseed Oil And Menthol 1.16%+10%+3%+ 5% , Diclofenac Sodium And Paracetamol Tablet 50 + 325 Mg , Diclofenac Sodium Injection - For Im And Iv 25 Mg/Ml , Diclofenac Sodium Tablet 50 Mg , Diclofenac Tablet (Sr) 100 Mg , Etoricoxib Tablet 90 Mg , Etoricoxib Tablet Ip 120 Mg , Ibuprofen And Paracetamol Tablet 400 Mg + 325 Mg , Ibuprofen Oral Suspension 100 Mg/5Ml , Paracetamol Drops 150 Mg/Ml , Paracetamol Syrup Ip 125 Mg/5Ml , Paracetamol Tablet 500 Mg , Paracetamol Injection 150 Mg/Ml , Inj Diclofenac Sodium Aqueous 75Mg/Ml 1Ml Size, Iv & Im Use , Paracetamol Infusion Ip 1% W/V 100Ml Size , Tab. Ketorolac 10 Mg , Chlorzoxazone, Diclofenac Sodium & Paracetamol Tablet 250Mg+50Mg+325 Mg , Hydroxychloroquine Sulphate Tablet 200 Mg , Betamethasone Sodium Phosphate Injection 4 Mg/Ml , Dexamethasone Injection 8 Mg/2Ml , Hydrocortisone Sodium Succinate Injection 100 Mg Base / Vial , Methyl Prednisolone Sodium Succinate For Injection 500 Mg , Adrenaline Injection 1 Mg/Ml , Chlorpheniramine Maleate Tablet 4 Mg , Hydroxyzine Tablet 25 Mg , Pheniramine Injection 22.75 Mg/Ml , Promethazine Syrup Ip 5 Mg/ 5Ml , Promethazine Injection 25 Mg/Ml , Promethazine Tablet 25 Mg , Anticold Syrup: Phenylephrine Hcl , Chlorpheniramine Maleate, And Paracetamol 2.5Mg+ 1 Mg+125 Mg/5Ml , Cetirizine, Phenylephrine& Paracetamol Tablet 5 Mg + 10 Mg + 325 Mg , Cetirizine Syrup 5 Mg/Ml , Levoceitrizine Tablet 5Mg , Montelukast 10 Mg + Levocetrizine 5Mg Tablet , Pralidoxime Chloride Injection 25 Mg/Ml , N- Acetylcystine Injection 200 Mg/Ml , Carbamazepine Oral Suspension Usp 100 Mg/5 Ml , Phenytoin Injection 50 Mg/Ml , Phenytoin Oral Suspension 25 Mg/Ml , Phenytoin Tablet 100 Mg , Pregabalin Capsule Ip 75 Mg , Sodium Valproate Ip Injection 100 Mg/Ml , Sodium Valproate Tablet 200 Mg , Sodium Valproate Oral Solution Ip 200 Mg/ 5 Ml , Sodium Valproate(Gastro-Resistant) Ip Tablet 500 Mg , Clobazam Tablet/Capsule 5 Mg , Clobazam Tablet/Capsule 10 Mg , Levetiracetam Tablet 500 Mg , Levetiracetam Oral Solution Suspension 100 Mg/Ml , Levetiracetam Injection 500 Mg/5Ml , Amikacin Injection 100 Mg , Amikacin Injection 250 Mg , Amikacin Injection 500 Mg , Gentamycin Injection 80 Mg/2Ml , Amoxycillin Capsule 250 Mg , Amoxycillin Capsule 500 Mg , Amoxycillin Trihydrate Dispersible Tablet 125 Mg , Amoxycillin Oral Suspension (Dry Syrup) 125 Mg/5Ml , Amoxycillin And Cloxacillin Capsule 250 Mg + 250 Mg , Amoxycillin And Potassium Clavulanate Tabs 500 Mg + 125 Mg , Amoxicillin And Clavulanic Acid Injection 600 Mg , Amoxicillin And Potassium Clavulanate Injection 1.2 Gm , Amoxycillin & Clavulanic Acid Syrup 200 Mg + 28.5 Mg / 5 Ml , Ampicillin Capsule 500 Mg , Ampicillin Injection Ip 500 Mg , Benzathine Benzylpenicillin Injection Ip12 Lac Units , Benzathine Benzylpenicillin Injection 6 Lac Units , Cloxacillin Sodium Injection 500 Mg , Piperacillin And Tazobactum For Injection 4 Gm + 500 Mg With Monocart +10Ml D. Water , Tab. Amoxycillin 250 Mg+Calvulanic Acid 125 Mg Ip Each Film Coated Tab Conatin Amoxycillin Trihydrate Ip 250 Mg & Potassium Clavulanate Ip 125 Mg , Inj Piperacillin 2 Gm + Tazobactom 250Mg Usp , Cefepime Injection 500 Mg (Monocart + D.Water) , Cefixime Tablet 100 Mg , Cefixime Tablet 200 Mg , Cefixime Oral Susp (Drops) 25 Mg/Ml , Cefoperazone And Sulbactum For Injection 1 G + 0.5 G , Cefotaxime Injection 1 G (Monocart + D.Water) , Cefotaxime Injection 250 Mg (Monocart + D.Water) , Cefpodoxime Dispersible Tablet 50 Mg , Ceftazidime Injection 1 G (Monocart + D.Water) , Ceftazidime Injection 250 Mg (Monocart + D.Water) , Ceftazidime Injection 500 Mg (Monocart + D.Water) , Ceftriaxone Injection Ip 1 G/Vial (Monocart + D.Water) , Ceftriaxone Injection 250 Mg (Monocart + D.Water) , Ceftriaxone Injection Ip 500 Mg/Vial (Monocart + D.Water) , Cefuroxime Tablet 250 Mg , Cephalexin Capsule 250 Mg , Cephalexin Capsule Ip 500 Mg , Cephalexin Oral Suspension ( Cephalexin Dry Syrup) 125 Mg/ 5Ml , Cephalexin Tablet (Dt) 125 Mg , Inj. Ceftriaxone 1 Gm + Tazobactum 125 Mg (Monocart + D.Water) , Tab.Cefadroxil 250 Mg , Tab.Cefadroxil 500 Mg , Azithromycin Tablet (Dt) 100 Mg , Azithromycin Tablet Ip 250 Mg , Azithromycin Tablet 500 Mg , Ciprofloxacin Injection 200 Mg/ 100 Ml , Ciprofloxacin Tablet 250 Mg , Ciprofloxacin Tablet 500 Mg , Levofloxacin Tablet 250 Mg , Norfloxacin Tablet 400 Mg , Ofloxacin Tablet 200 Mg , Ofloxacin Suspension 50 Mg/5 Ml , Ofloxacin Injection 200Mg / 100 Ml , Ofloxacin And Ornidazole Tablet 200 Mg + 500 Mg , Ofloxacin Oral Suspension Ip (Each 5Ml Contains Ofloxacin Ip 100 Mg) , Tab. Levofloxacin Ip 500 Mg (Each Film Coated Tablet Contains Levofloxacin Hemihydrate Ip 500 Mg) , Clindamycin Capsule 150 Mg , Clindamycin Capsule 300 Mg , Co-Trimoxazole Oral Suspension 40 Mg + 200 Mg Per 5Ml , Doxycycline Capsule 100 Mg , Linezolid Tablet Ip 600 Mg , Linezolid Injection 200 Mg/100 Ml , Meropenem Injection 500 Mg (Monocart + D.Water) , Meropenem Injection 1 G (Monocart + D.Water) , Nitrofurantoin Tablet 100 Mg , Vancomycin Injection 500 Mg , Vancomycin For Intravenous Infusion Ip 1 Gm , Framycetin Sulphate Cream 1% , Framycetin Sulphate Cream 1% , Inj Clindamycin Phosphate Ip 300 Mg , Metronidazole Injection 500 Mg/ 100 Ml , Metronidazole Benzoate Oral Suspension 100 Mg/ 5 Ml , Albendazole Oral Suspension 400 Mg/ 10 Ml , Albendazole Tablet Ip 400 Mg , Clotrimazole Cream Ip 2% W/W , Clotrimazole Vaginal Tablet 500 Mg , Fluconazole Tablet 150 Mg , Griseofulvin Tablets 125 Mg , Itraconazole Capsule 100 Mg , Tab. Terbinafine Hydrochloride 250 Mg , Artisunate Injection 60 Mg (Combo Pack With 1 Ml Ampoule Of 5% Sodium Bicarbonate Injection And 5 Ml Ampoule Of 0.9% Sodium Chloride Injection) , Chloroquine Phosphate Injection 40 Mg/Ml , Chloroquine Phosphate Tablet 250Mg (=155 Mg Of Chloroquine Base) , Chloroquine Phosphate Suspension 50 Mg/ 5Ml , Primaquine Tablet 2.5 Mg , Primaquine Tablet 7.5 Mg , Artemether + Leumefantrine Tablet (40 Mg And 240 Mg) , Artemether + Leumefantrine Tablet (80 Mg And 480 Mg) , Acyclovir Tablet 200 Mg , Acyclovir Tablet 800 Mg , Acyclovir Suspension 400 Mg/ 5Ml , Acyclovir Injection 250 Mg , Acyclovir Injection 500 Mg , Bromocriptine Mesylate Tablet 2.5 Mg , Levodopa And Carbidopa Tablet 100 Mg + 10 Mg , Levodopa And Carbidopa Tablet 250 Mg + 25Mg , Trihexyphenidyl Hydrochloride Tablet 2 Mg , Enoxaparin Sodium Injection 60 Mg , Heparin Sodium Injection 5000 Iu/Ml , Warfarin Sod. Tablet 5 Mg , Ethamsylate Injection 250 Mg/ 2Ml , Tranexamic Acid Tablet 500 Mg , Vitamin K Injection 10 Mg/Ml , Tab Ethamsylate Bp 500 Mg (Each Uncoated Coated Tablet Contains Ethamsylate Bp 500 Mg) , Inj Tranexamic Acid Ip 100Mg/Ml 5Ml Size , Rh-Erythropoetin Injection 10000 Iu , Rh-Erythropoetin Injection 2000 Iu , Rh-Erythropoetin Injection 4000 Iu , Human Albumin Solution 20% , Streptokinase Injection 15 Lac Units , Urokinase Injection 5 Lac Unit , Aspirin Delayed Release Tablet (Enteric Coated) 75 Mg , Clopidogrel Tablet Ip 75 Mg , Clopidogrel And Aspirin Tablet 75 Mg + 75 Mg , Amlodipine Tablet Ip 2.5 Mg , Amlodipine Tablet 5 Mg , Atenolol Tablet 50 Mg , Atenolol Tablet 25 Mg , Diltiazem Tablet 30 Mg , Enalapril Maleate Tablet 10 Mg , Enalapril Maleate Tablet 5 Mg , Enalapril Maleate Tablet 2.5 Mg , Labetalol Tablet 100 Mg , Labetalol Hydrochloride Injection 20 Mg/ 4Ml , Lisinopril Tablet 2.5 Mg , Lisinopril Tablet 5 Mg , Lisinopril Tablet 10 Mg , Losartan Tablet 25 Mg , Losartan Tablet 50 Mg , Amlodipine And Enalapril Maleate Tablet 5 Mg +5Mg , Losartan Potassium & Amlodipine Tablet 50 Mg + 5Mg , Losartan Potassium & Hydrochlorothiazide Tablet 50 Mg + 12.5Mg , Amlodipine And Lisinopril Tablet 5Mg +5 Mg , Amlodipine And Atenolol Tablet 5 Mg +50 Mg , Methyldopa Tablet 250 Mg , Metoprolol Tablet Ip 25 Mg , Metoprolol Suscinate Tablet (Extended Release) Usp 50 Mg , Nifedipine Capsule 5 Mg , Nifedipine Tablet (Sustained Release) 10 Mg , Prazosin Tablet (Extended Release) 2.5 Mg , Propranolol Tablet 40 Mg , Ramipril Tablet / Capsule 2.5 Mg , Telmisartan Tablet Ip 40 Mg , Glyceryl Trinitrate Tablet 2.6 Mg , Isosorbide Dinitrate Tablet 5 Mg , Isosorbide Mononitrate Tablet 20 Mg , Nitroglycerin Injection 5 Mg/Ml , Atorvastatin Tablet 10 Mg , Atorvastatin Tablet 40 Mg , Tab Rosuvastatin Ip 20 Mg (Each Film Coated Tablet Contains Rosuvastatin Calcium Ip Equivalent To Rosuvastatin 20 Mg) , Tab Rosuvastatin 10 Mg , Digoxin Injection 0.25 Mg/Ml , Digoxin Tablet 0.25 Mg , Dobutamine Injection 50 Mg/Ml , Dopamine Hydrochloride Injection 40 Mg/Ml , Noradrenaline Injection 2 Mg/Ml , Magnesium Sulphate Injection (50% ) 500 Mg/Ml , Chlorhexidine Mouthwash Bp 0.20% , Dental Gel: Choline Salicylate + Benzalkonium + Lignocaine 8.75% , Desensitizing Tooth Gel With Sodium Mono Fluoro Phosphate & Pot. Nitrate 0.7%+ 5 % , Gum Paint Containing Tannic Acid , Cetrimide , Zinc Chloride 2%+0.1%+1% , Metronidazole And Chlorhexidine Gel 1%+ 0.25% , Miconazole Nitrate Cream 2% , Clotrimazole Mouth Paint (Clotrimazole 1% W/V) 1% , Ketoconazole Cream 2% , Powder Clotrimazole 1% W/W 30 Gm , Beclomethasone, Neomycin And Clotrimazole Cream 0.025% + 0.5% + 1% , Clindamycin Phosphate Gel Usp 1% , Fusidic Acid Cream 2% , Cream Mupirocin Usp 2% (Each Gram Contains 21.5 Mg Mupirocin Calcium Usp In A Mineral Oil Cream Base) 15 Gm Size , Betamethasone Dipropionate Cream 0.05% , Betamethasone Lotion 0.05% , Clobetasol Cream 0.05% , Acyclovir Cream 5% , Gamma Benzene Hexachloride Lotion(Lindane Lotion Usp) 1% , Permethrin Cream 5% , Permethrin Lotion 5% , Coal Tar 6% & Salicylic Acid 3% Onitment , Glycerin Ip 100 Ml , Glycerin Ip 400 Gm , Calamine Lotion Ip , Compound Benzoic Acid Ointment Ip Benzoic Acid 6%+ Salicylic Acid 3% , Tretenoin Cream 0.03% , Anti A Blood Grouping Serum (Anti A Monoclonal Serum Ip) Tulip , Anti B Blood Grouping Serum Tulip , Anti Drh Blood Grouping Serum Tulip , Multistix Test Strip (Ctk) , Cetrimide Cream Ip 0.50% , Chlorhexidine Gluconate Solution 5% , Compound Benzoin Tincture Ip , Formaldehyde Solution (34.5% - 38%) , Gentian Violet Topical Solution Usp 1% , Glutaraldehyde Solution 2% , Hydrogen Peroxide Solution 6% , Povidone Iodine Solution 5% , Povidone Iodine Solution 5% , Povidone Iodine Solution 10% , Povidone Iodine Scrub Solution / Cleansing Solution 7.5% W/V Povidone Iodine 7.5% , Povidone Iodine Ointment 5% , Povidone Iodine Ointment 5% , Silver Sulphadiazine Cream 1% , Silver Sulphadiazine Cream Ip 1% , Surgical Spirit Bp , Acetazolamide Tablet 250 Mg , Furosemide Tablet 40 Mg , Furosemide Injection 10 Mg/Ml , Hydrochlorthiazide Tablet 12.5 Mg , Hydrochlorthiazide Tablet 25 Mg , Mannitol Injection 20% , Spironolactone Tablet 25 Mg , Spironolactone Tablet 50 Mg , Torsemide Tablet 10 Mg , Torsemide Injection 10 Mg/Ml , Ciprofloxacin And Dexamethasone Ear Drops 0.3% + 0.1% , Clotrimazole 1% With Beclomethasone Dipropionate 0.025% Ear Drops , Neomycin, Polymixin B & Hydrocortisone Ear Drops/Otic Solution Usp (Neomycin Sulphate 3400 Iu, Polymixin B Sulphate 10000 Iu And Hydrocortisone 10 Mg Per Ml) , Wax Dissolving Ear Drops: Paradichlorobenzene , Benzocaine ,Chlorobutanol, Turpentine Oil 2% + 2.7% + 5% + 15% , Antacid Liquid , Omeprazole Capsule 20 Mg , Pantoprazole Injection 40 Mg , Pantoprazole & Domperidone Special Repair Capsule 40 Mg+ 30 Mg , Ranitidine Hcl Injection 50 Mg/2Ml , Ranitidine Tablet 150 Mg , Ranitidine Tablet 300 Mg , Dicyclomine Tablet 10 Mg , Dicyclomine Injection 10 Mg/Ml , Dicyclomine Hydrochloride Oral Solution Ip10 Mg/5Ml , Dicyclomine Hydrochloride And Activated Dimethicone Suspension 10Mg + 40Mg Per Ml , Dicyclomine And Paracetamol Tablet 20Mg + 325Mg , Drotaverine Tablet 40 Mg , Drotaverine Hydrochloride Injection 40 Mg/2Ml , Drotaverine & Mefenamic Acid Tablet 80 Mg + 250 Mg , Hyoscine Butylbromide Tablet 10 Mg , Hyoscine Butylbromide Injection Ip 20 Mg/Ml , Metoclopramide Injection 10 Mg/2Ml , Metoclopramide Tablet 10 Mg , Metoclopramide Syrup 5 Mg/ 5Ml , Domperidone Tablet 10 Mg , Domperidone Oral Drops 10 Mg/ Ml , Domperidone Suspension 5 Mg/ 5Ml , Ondansetron Orally Disintegrating Md Tablet 4 Mg , Ondansetron Injection 2 Mg/Ml (Blister Pack) , Tab Doxylamine Succinate 20 Mg & Pyridoxine Hydrochloride 20 Mg (Each Enteric Coated Tablet Contains Doxylamine Succinate Usp 20 Mg & Pyridoxine Hydrochloride Ip 20 Mg ) , Inj Prochlorperazine Mesylate 12.5Mg/Ml 5Ml Size , Bisacodyl Tablet 5 Mg , Lactic Acid Bacillus Tablet 60 Million Spores , Lactulose Solution 10Gm/15Ml , Loperamide Tablet Ip 2 Mg , Ors Powder , Ointment Containing : Lidocaine 3%, Zinc Oxide 5% , Hydrocortisone 0.25%, Allantoin 0.5% , Sodium Phosphates Enema Bp , Probiotic Sachets 1 Gm Size (Each Gram Sachet Contains Saccharomyces Boulardii 250Mg & Lactic Acid Bacillus 150 Million Spores) , Ursodeoxycholic Acid Tablet 300 Mg , Tab. Mesalamine Usp 1.2 Gm Enteric Coated (Each Enteric Coated Prolonged Release Tablet Conatin Mesalamine Usp 1.2 Gm) , Biphasic Isophane Insulin Injection 30 / 70 (30% Soluble Insulin & 70% Isophane Insulin) 40 Iu / Ml , Isophane Insulin Injection 40 Iu / Ml , Soluble Insulin Injection 40 Iu / Ml , Glibenclamide Tablet 5 Mg , Gliclazide Tablets Ip 40 Mg , Glimepiride Tablet 2 Mg , Glimepiride Tablet 1 Mg , Glipizide Tablet Ip 5 Mg , Metformin Tablet 500 Mg , Pioglitazone Tablet Ip 15 Mg , Metformin Hydrochloride Special Repair Tablet 1000 Mg , Glipizide And Metformin Hydrochloride Tablet 5 Mg + 500 Mg , Glibenclamide And Metformin Hydrochloride (Sr) Tablet 5 Mg + 500 Mg , Metformin Hydrochloride (Sr) And Glimepiride Tablet 500 Mg + 1 Mg , Metformin Hydrochloride (Sustained Release) And Glimepiride Tablet 500 Mg + 2 Mg , Glimepiride, Pioglitazone And Metformin Hydrochloride (Sr) Tablet 2Mg + 15Mg + 500Mg , Gliclazide And Metformin Tablet 80 Mg + 500 Mg , Insulin Glargine 100 Iu/Ml With 15 Insulin Syringes And Needles/Cartridge 100 Iu/Ml With 15 Needles And 1 Pen Per 20 Cartridges , Insulin Glargine 100 Iu/Ml With 30 Insulin Syringes With Needle , Tenaligliptin Tablet 20 Mg , Carboprost Tromethamine Injection 0.25 Mg/Ml , Hydroxyprogesterone Injection 250 Mg/Ml , Norethisterone Tablet 5 Mg , Progesterone Injection 200 Mg /2Ml , Medroxyprogesterone Acetate Tablet Ip 10 Mg , Thyroxine Sodium Tablet 100 Mcg , Thyroxine Sodium Tablets Ip 50 Mcg , Human Anti D Immunoglobulin Injection (Im Use) 300 Mcg , Human Anti D Immunoglobulin 150 Mcg , Human Rabies Immunoglobulin Injection 150 Iu/Ml , Rabies Vaccine Human (Cell Culture) (Intradermal) 2.5 Iu , Rabies Vaccine Human (Cell Culture) (Intramuscular) 2.5 Iu/ Dose , Rabies Antiserum Ip (Equine) (I.M./Sc Use) 300 Units / Ml , Snake Venom Anti Serum (Polyvalent Anti Snake Venom) Lyophillized , Normal Human Intravenous Immunoglobulin 5G/100Ml , Tetanus Immunoglobulin 250 Iu , Inj. Hepatitis B Immunologlobin Ip 100 I.U , Inj. Human Immunologlobin 12%Igm, 12%Iga &76% Igg 10 Ml(0.5 Gm) , Chloramphenicol Eye Drops 0.05% , Ciprofloxacin Eye Drops 0.30% , Ciprofloxacin Ophthalmic Ointment 0.30% , Tobramycin And Dexamethasone Ophthalmic Suspension 0.30%+0.10% , Tobramycin Eye Drops 0.30% , Tobramycin Ophthalmic Ointment 0.30% , Eye Drop Moxifloxacin 0.5% W/V Ophthalmic Solution Ip 5Ml Size , Chloramphenicol 1% W/W Eye Ointment Ip, 3Gm Size , Lidocaine Hydrochloride Topical Solution Usp 4% , Carboxymethylcellulose Sodium Lubricant Eye Drops 0.50% , Hyaluronidase Injection 1500 Iu , Hydroxypropylmethyl Cellulose Solution With Prefilled Glass Syringe With Cannula 20 Mg/Ml , Isoxsuprine Injection 5 Mg/Ml , Isoxsuprine Tablet 20 Mg , Methylergometrine Injection 0.2 Mg/Ml , Methylergometrine Tablet Ip 0.125 Mg , Misoprostol Tablet 200 Mcg , Oxytocin Injection 5 Iu/Ml (Blister Pack) , Natural Micronised Progesteron Soft Gelatin Capsule 200 Mg (Each Soft Gelatin Capsule Contains Progesteron Ip 200 Mg) , Tab Cabergoline Ip 0.5Mg (Each Uncoated Coated Tablet Contains Cabergoline Ip 0.5Mg) , Inj Human Chorionic Gonadotropin Ip 5000 I.U. , Amitriptyline Tablets Ip 25 Mg , Escitalopram Tablets Ip 10 Mg , Fluoxetine Capsule Ip 20 Mg , Imipramine Tablet 25 Mg , Imipramine Tablet 75 Mg , Lithium Carbonate Tablet 300 Mg , Sertraline Tablet 50 Mg , Alprazolam Tablet 0.25 Mg , Alprazolam Tablet 0.5 Mg , Clonazepam Tablet 0.5 Mg , Diazepam Injection 10 Mg/ 2Ml , Diazepam Tablet 5 Mg , Lorazepam Injection 2 Mg/Ml , Tab. Lorazepam Ip 2 Mg (Each Uncoated Tablet Contains Lorazepam Ip 2 Mg ) , Aminophylline Injection 25 Mg/Ml , Beclomethasone Inhalation 200 Mcg/ Dose , Budesonide Nebulizer Suspension 0.25 Mg/Ml , Budesonide Rotacap 200 Mcg , Ipratropium Bromide Nebulizer Solution 250 Mcg/Ml , Ipratropium Rotacap 40 Mcg , Salbutamol Tablet 4 Mg , Salbutamol Inhalation 100 Mcg/ Dose , Salbutamol Nebuliser Solution 5 Mg/Ml , Salbutamol Tablet 2 Mg , Salbutamol Syrup Ip 2 Mg/5Ml , Terbutaline Sulphate Tablet Ip 2.5 Mg , Theophylline And Etophylline Injection 50.6Mg + 169.4Mg , Theophylline And Etophylline Tablet 23Mg + 77Mg , Theophylline Tablet (Sr) 400 Mg , Formoterol & Budesonide Rotacap 6 Mcg+ 200 Mcg , Tab. Acebrophylline 100 Mg , Cough Syrup [Each 5Ml Contains Chlorpheniramine Maleate Ip 3Mg Ammonium Chloride 130 Mg, Sodium Citrate 65 Mg, Menthol 0.5 Mg] , Dextromethorphan Hydrobromide Syrup 13.5 Mg/ 5Ml , Cough Syrup/ Expectorant (Ambroxol Hydrochloride Ip 15 Mg, Terbutaline Sulphate Ip 1.5 Mg, Guaiphenesin Ip 50 Mg, Menthol Ip 1 Mg , Saline Nasal Solution (Drops) 0.65% , Xylometazoline Nasal Drops 0.1% , Compound Sodium Lactate Injection Ffs , Dextrose Injection 25% Ffs , Dextrose Injection 10% Ffs , Dextrose Injection 5% Ffs , Multiple Electrolytes & Dextrose Injection Type I Ip (Electrolyte P Injection ) Ffs , Multiple Electrolytes & Dextrose Injection Type Iii Ip (Electrolyte M Injection) Ffs , Potassium Chloride Injection 0.15 Gm/Ml , Potassium Chloride Oral Solution Usp 500 Mg/ 5Ml , Sodium Chloride And Dextrose Injection 0.9 % + 5 % Ffs , Sodium Chloride Injection Ffs , Sodium Chloride Injection Ffs , Ringer Acetate Infusion 500 Ml Ffs , Sodium Chloride 0.45% W/V Polypack 500 Ml , Syp. Alkylizer 1.4 Gm/5 Ml ( 100 Ml ) (Disodium Hydrogen Citrate) , Betahistine Tablet Ip 8 Mg , Betahistine Tablet Ip 16 Mg , Cinnarizine Tablet Ip 25 Mg , Cinnarizine Tablet Ip 75 Mg , Ascorbic Acid Tablet 500 Mg , Calcium Gluconate Injection 10% , Calcium & Vitamin D3 Tablet 500 Mg + 250 Iu , Calcium & Vitamin D3 Suspension (Each 5 Ml Contains Calcium Carbonate Equivalentvto Elemental Calcium 250 Mg + Vitamin D3 -125 Iu) , Ferrous Sulphate And Folic Acid Tablet 100 Mg + 0.5 Mg , Ferrous Sulphate With Folic Acid Tab.(Paediatric) 20 Mg + 0.1 Mg , Folic Acid Tablet Ip 5 Mg , Iron And Folic Acid Syrup Each 5 Ml Contains Ferrous Fumerate Equivalent To Elemental Iron 100 Mg, Folic Acid 500 Mcg , Iron Sucrose Injection 20 Mg/Ml Usp/Bp 20 Mg/Ml (For Iv Use) Each Ml Contain : Ferric Hydroxide In Comples With Sucrose Equivalent To Elemental Iron 20 Mg , Mecobalamin Injection 500 Mcg/Ml , Multivitamin Drops Each Ml Contains Vit-A-3000 Iu, Vit D3- 300Iu, Vit-B 1-1Mg, Riboflavine Phosphate Sodium- 2 Mg, D- Pantenol- 2.5 Mg, Niacinamide - 10 Mg, Pyridoxine Hcl - 1 Mg, Cyanocobalamin 1 Mcg, Lysine Hcl 10 Mg , Multivitamin Tablets Nfi Formula Sugar Coated.Vit A 2500 Iu , Vitamin A Solution 1 Lac Iu/Ml , Vitamin B Complex Tablet Nfi (Prophylactic) , Vitamin B Complex Injection Nfi , Zinc Sulphate Dispersible Ip Elemental Tablet 10 Mg , Methylcobalmin Tablet 500 Mcg , Methylcobalmin Tablet 1500 Mcg , Vitamin D3 Oral Solution 60000 Iu , Multi Vitamin Syrup , Flunarizine Tablet 5 Mg , Black Disinfectant Fluid (Phenyl) (As Per Schedule O Grade - Iii , Sodium Bicarbonate Injection Ip 7.5% , Water For Injection Ip , Inj. Amino Acid 10% 100Ml Size , Cap. Vitamin E 400 Mg , Inj. Fcm 500Mg , Bleaching Powder 500Gm , Cap. Antioxidant , List Of Surgicals , Blood Administration Set / Blood Transfusion Set • Sharp And Easy Piercing Spike Suitable For Blood Bags And Standard Blood Containers • Transparent Cylindrical Drip Chamber With Filter.Filter Size Should Be 200+20 Micrometer. • 150 Cm Long Smooth Kink Resistant Tubing • Efficient Roller Clamp To Control And Adjust The Transfusion Rate • Should Conform To Is 9824(Part 3):1996 , Disposable Sterile Surgical Rubber Gloves Size 6 ½ Inches • Made Of Natural Rubber Latex, Powder Free (Polymer /Silicon Coated), Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Should Conform To Is 13422 Isi Marked / Ce Certified / Fda Approved (Ce Certification / Fda Approval For Item Is Mandatory For Importer Firms, That Cannot Avail Is Standards) , Disposable Sterile Surgical Rubber Gloves Size 7 Inches • Made Of Natural Rubber Latex, Powdered,,Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Powder Should Be Non-Allergenic • Should Conform To Is 13422 • Isi Marked / Ce Certified / Fda Approved , Disposable Sterile Surgical Rubber Gloves Size 7½ Inches • Made Of Natural Rubber Latex, Powdered, Without Tear, Properly Folded In A Paper • Free Of Holes, With Acceptable Quality Level (Aql) Of 1.5 Or Less • Tensile Strength As Per En 455-2 • Powder Should Be Non-Allergenic • Should Conform To Is 13422 • Isi Marked / Ce Certified / Fda Approved , Suction Catheter, Sterile. Size: Fg 5 (For Use In Respiratory Tract) • Soft, Kink Resistant Tubing • Rounded Open Tip With Lateral Eye • Colour Coded Universal Funnel Connector For Safe Connection To Standard Suction Equipment • Length 50 Cm (Min.) • Should Conform To Is0 8836:2014 , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size22 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Sterile Catheter, Single Use, For Urinary Drainage (Foley Balloon Catheter), 2 Way, Size 24 Fg • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For Atraumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30 ± 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Balloon Capacity Should Be Mentioned As Per Is 11497. • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is11497 For Particular Size , Infant Feeding Tube Size:10Fg Length 50 Cm (Min.) • Two Lateral Eyes At Distal End • Soft, Kink Resistant Non-Toxic Pvc Tubing, Non Irritant To Delicate Mucosa • With Female Flexible Mount With In-Built Closure • Radio Opaque Line • Sterile 5 To 10 , Sterile Disposable Perfusion Set With Airway And Needle (Adult Use) (Romson) • For Gravity Feed Only • Sharp And Easy Piercing Spike With Air Vent • Transparent And Flexible Drip Chamber • 150 Cm Long Smooth Kink Resistant Tubing • Self Sealing Latex Bulb Which Will Also Act As An Port For Extra Medication • Efficient Roller Clamp To Control And Adjust The Fluid Rate • 21 G Needle • Should Conform To Is 12655 -4 Standard , Sterile Disposable Perfusion Set (Infusion Set) With Airway And Needle (Paediatric Use) • Burette Type Measured Volume Chamber Of 100 Ml • Drop Size Of Approx 60 Drops Per Ml • Injection Port,Latexfree, For Intermittent Medication. • Floating Auto Shut Off Valve (Latex Free) In Burette. • Soft And Kink Resistant Pvc Tubing. • Roller Controller For Flow Control • Tube Length 150 Cm • 23G Needle • Should Conform To Iso 8536-5 , Insulin Syringe ( 40 Units) With (Fixed) 30 G Needle Shall Conform To Is 12227 , Sterile Disposable (Single Use) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 20G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use) Teflon / Ptfe I.V. Cannula With Integrated 3 Way Stop Cock. Size 22G • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Sterile Disposable (Single Use) Teflon/ Ptfe I.V. Cannula Without Port. Size 24G • Suitable For Paediatric & Neonatal Use • Should Be Packed In Transparent, Single Blister Pack. • Should Conform To Is 10555 Standard , Mucus Extractor Sterile • Clear Transparent Container • Antibacterial Filter • Soft, Kink Resistant Pvc Tubing • Tube Size 10 Fg; Length 40 Cm (Min.) • Capacity 25 Ml , Nasal Oxygen Cannula (Set), Twin Bore (Accessory For Compressed Air Breathing) All Sizes (Adult) • Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volume Of Oxygen To Both Air Passages • Connector For Easy Connection To The Oxygen Source • Tube Length 200 Cm , Nasal Oxygen Cannula (Set), Twin Bore (Accessory For Compressed Air Breathing) All Sizes (Pediatrics) • Soft And Kink Resistant Pvc Tubing • Multichannel / Star Lumen To Preventing Accidental Kinking • Twin Bores Should Ensure Equal Volume Of Oxygen To Both Air Passages • Connector For Easy Connection To The Oxygen Source • Tube Length 200 Cm , Paper Adhesive Plaster 1 X 9.0 Mts (With Cutter) Non Woven Adhesive Tape,Hypoallergic,Should Have Some Stretch Bonding , Paper Adhesive Plaster 2 X 9.0 Mts (With Cutter) Non Woven Adhesive Tape Hypoallergic, Should Have Some Stretch Bonding , Paper Adhesive Plaster 3 X 9.0 Mts (With Cutter) Non Woven Adhesive Tape Hypoallergic, Should Have Some Stretch Bonding , Plaster Of Paris Bandages 15Cm X 2.7Mts / Roll Should Conform To Schedule F(Ii) Of Drug And Cosmetic Act 1940 , Plaster Of Paris Bandages 10Cm X 2.7Mts / Roll Should Conform To Schedule F(Ii) Of Drug And Cosmetic Act 1940 , Ryles Tube / Nasogastric Tube (P.V.C.) With Radio Opaque Lining. Size: 10 • Soft, Kink Resistant Pvc Tubing For Atraumatic Intubation • Closed Distal End Should Be Coned With Radio Opaque Material For Accurate Intubation • Four Lateral Eyes For Greater Efficiency • Radio Opaque Line • Marking At 50, 60, 70 Cm From Tip • Colour Coded Funnel • With Luer Connector / Closure • Length 105 Cm , Scalp Vein Set (Disposable): Size 18G • Butterfly Shaped Wings For Easy Handling And Attachment With Skin. Colour Coded • Needle Should Be Bevelled, Siliconised And Should Ensure Atraumatic Cannulation • Female Luer Fitting At One End • Soft, Kink Resistant, Non-Toxic, Non Irritant Tube • Sterile , Sterile Hypodermic Syringe With Needle Attached, 24G, Single Use - 2 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container , Sterile Hypodermic Syringe With Needle Attached, 24G, Single Use - 5 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 10 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 20 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Surgical Blade Sterile, Size 11 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Surgical Blade Sterile, Size 15 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Surgical Blade Sterile, Size 22 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Suture Needles Curved 1/2 Circle Round Body Assorted Size 16-20 • It Should Be Mentioned Whether Needle Is Pointed Or Blunt With Type Of Its Point. • Type Of Eye Of The Needle Should Be Mentioned. • Should Conform To Is-9165 , Sterile Disposable Spinal Needle For Single Use 22G X 3 ½ Inch • Clear / Transparent Hub • Sharp Tip Which Should Ensure Minimal Puncture Trauma , Sterile Disposable Spinal Needle For Single Use 25G X 3 ½ Inch • Clear / Transparent Hub • Sharp Tip Which Should Ensure Minimal Puncture Trauma , Urine Collecting Bag, Disposable 2000 Ml • Transparent Sheet • Kink Resistant Flexible Tubing Not Less Than 90 Cm In Length • Should Have Non-Return Valve • Top Drainage Outlet • Graduated Bag • Moulded Handle For Easy Handling , Endotracheal Tube, Plain - Size 2.5Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile 2.5 To 5.0 , Endotracheal Tube, Plain - Size 3Mm • Transparent • Standard 15 Mm Connector At Proximal End • Radio-Opaque Line Throughout The Length • Tip Suitable For Nasal And Oral Intubation • Single Use, Sterile 5.5 To 7.5 , Endotracheal Tube, Cuffed - Size 4Mm (4.0 To 6.5) • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Endotracheal Tube, Cuff - Size 7Mm (7.0 To 8.5) • Soft Cuff Towards The Distal End • Kink Resistant Inflation Tube • Murphy Eye At Distal End With Polished Smoothness • Radio-Opaque Line • Standard 15 Mm Connector • Sterile, Single Use • Curved Shaped Blister Pack - Suiting The Shape Of Product , Face Mask, Disposable • Should Be Manufactured From Non Woven Poly Prop Fabric • Should Be 3 Ply Construction • Should Have High Bacterial Filtration Efficiency • Should Be Heat Sealed To Keep 3 Layers Together • Standard Size 17.5 X9 Cm • Color Green/Blue • There Should Be A String Each At All Four Corners,Length Of String Should Be 40Cm • Nose Clip Should Be There • No Elastic Band. , Surgical Cap, Disposable ( For Nurses) • Should Be Manufactured From Non Woven Fabric • Blue / Green Colour • Round Upon Wearing, With Elastic • Air Permeable / Breathable • Should Retain Skin And Hair Particles , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Extra Small. Should Conform To Is 15354 , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Small Should Conform To Is 15354 , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Medium Should Conform To Is 15354 , Rubber Examination Gloves Made Of Natural Rubber Latex. Non-Sterile, Ambidextous, Aql 1.5 Micro Textured Powdered With Absorbable Dusting Powder Usp. Large Should Conform To Is 15354 , Umbilical Catheter (For New Born) All Sizes • Radio Opaque Line • With Female Flexible Mount • Colour Coded Connector • Open Tip Should Be Soft, Rounded, Atraumatic • Length 40 Cm , Umbilical Cord Clamp • Suitable For Clamping Umbilical Cord Of New Born • Security Lock To Prevent Accidental Opening After Clamping • Grooved Clamping Area , Sanitary Napkin, Beltless 1. Covering - Covering Of The Absorbent Filler Shall Be Good Quality Knitted Sleeve Or Non-Woven Fabric Which Has Sufficient Porosity To Permit The Assembled Napkin To Meet The Absorbency Requirements. The Napkins Shall Have A Non Absorbent Barrier On One Side Which Shall Have An Identifying Mark Indicating The Side Of The Barrier. 2. Absorbent Filler - The Filler Material Shall Consist Of Cellulose Pulp/ Wadding, And Shall Be Free From Lumps, Oil Spots, Dirt Or Foreign Material, Etc. 3. Back Strip - A Back Strip For Sticking The Sanitary Napkin Onto The Underwear Should Be There Using Good Quality Adhesive Material. 4. Size - The Size Of Absorbent Section / Complete Sanitary Napkin Shall Be As Follows: ( In Mm) Absorbent Section Total Pad Length 210 +_ 10 230 +_ 10 Width 60 To 75 70 To 85 Thickness 8 +_ 2 5. Weight : Not More Than 10 Gm . . Instruction For Usage Should Be Mentioned On Every Packet , Sanitary Napkin, Belttype 1. Covering - Covering Of The Absorbent Filler Shall Be Good Quality Knitted Sleeve Or Non-Woven Fabric Which Has Sufficient Porosity To Permit The Assembled Napkin To Meet The Absorbency Requirements. The Napkins Shall Have A Non Absorbent Barrier On One Side Which Shall Have An Identifying Mark Indicating The Side Of The Barrier. 2. Absorbent Filler - The Filler Material Shall Consist Of Cellulose Pulp/ Wadding, And Shall Be Free From Lumps, Oil Spots, Dirt Or Foreign Material, Etc 3. Size - The Size Of Absorbent Section / Complete Sanitary Napkin Shall Be As Follows: ( In Mm) Absorbent Section Pad Length 220 +_ 10 Width 70 +_ 5 Thickness 17 +_ 3 4. Weight : 12 +_ 3 Gm 5. Pack - Six Napkins In A Pack. 6. Elastic Belt With Loops Shall Be Provided In Each Pack. 7. Absorbency: The Napkin Should Be Able To Absorb Not Less Than 30 Ml Of Normal Saline Or Coloured Water Or Test Fluid When Poured On To The Centre Of The Napkin At The Rate Of 15 Ml Per Minute. .Instruction For Usage Should Be Mentioned On Every Packet. , Belt-Less Sanitary Napkin With Wings 1. Covering (Absorbing Top Sheet Corrector)-Good Quality Knitted Sleeve Or Non Woven Fabric Of Rash Free,Non Irritant And Soft To Touch Material Which Has Sufficient Porosity To Permit The Assembled Napkin To Meet Absorbency Requirements.The Napkins Shall Have A Non Absorbent Barrier On One Side With Adhesive Covered By A Differently Identifiable Paper 2.Overall Length (Mm) 230 ± 5 3.Core Length 220 Mm± 10 4.Fluff Core/Pad Length 220 Mm± 10 5. Over All Width With Wings 160Mm+_5 6.Fluff Core/Pad Length 70 Mm± 5 7.Thickness Of A Single Pad 9-10Mm 8. Weight Of A Single Pad : 8-10 Gm 9. Pack Six Napkins In A Pack. 10Type.- Belt-Less Sanitary Napkin With Wings 11. Minimum Absorbency: 50Ml 12.Ph Value Of Absorbent Material 6-8.5 B. Disposable Individual Pouch Or Wrapper For Each Sanitary Napkin(As Per Ministry Of Environment,Forest And Climate Change Dated 08.04.2016) Pouch/Wrapper Specifications :- 1. Pouch/Wrapper Should Be Of The Size Of Sanitary Napkin Being Supplied. 2. It Should Have Adhesive To Seal The Sanitary Napkins Within. 3. Pouch/Wrapper Should Not Be Transparent. Note : Instructions For Use Of Disposable Pouch/Wrapper Mst Be Written In Hindi On Disposable Pouch/Wrapper. Blrseky Fd;S Gq;S Lsusvjh Usifdu Dks Eksm Dj Disposable Pouch/Wrapper Esa Mkys ,Oa Disposable Pouch/Wrapper Dks Xksan Yxh Iv~Vh Ls Cun Dj Lqjf{Kr Rjhds Ls Dwmsnku Esa Mkysaa , Oxygen Mask (Adult) • Mould Facemask With Adjustable Elastic Strap For Proper Position Of Mask On The Mouth And Nasal Area • Friendly Soft Medical Pvc Material With Comfortable Fitting. • Aluminium Nasal Clip Provides Better Fixation. • Anatomical Design Provides Lighter Seal. • Latex Free Elastic Strap Available. , Oxygen Mask (Paediatric) • Mould Facemask With Adjustable Elastic Strap For Proper Position Of Mask On The Mouth And Nasal Area • Friendly Soft Medical Pvc Material With Comfortable Fitting. • Aluminium Nasal Clip Provides Better Fixation. • Anatomical Design Provides Lighter Seal. • Latex Free Elastic Strap Available. • Mask Connector 4M , Sterile Catheter, Single Use, For Urinary Drainage(Foley Baloon Catheter), 2 Way, Size 14 • Made Of Silicone Elastomer Bonded With Latex • Should Have Hard Plastic Valve • Smooth Distal End With Smooth Eyes For A Traumatic Intubation • Symmetrical Foley Balloon • Balloon Capacity 30+- 1 Ml • Should Conform To Is 11497 • Color Coding Marking To Identify Size • Length, Wall Thickness And Ballon Capacity Should Be Mentioned As Per Is 11497 • Specification For B,C,D,E,F,G Should Be Mentioned As Per Is 11497 , Nelaton - Catheter Size 14 Fg Distal End Is Close And Proximal End Has Female Colour Code Connector • Soft, Kink Resistant Medical Grade Pvc Tube • Length:40 Cm • Individually Packed In Poly And Sterile , Ecg Electrode •Reliable Trace, •High Conductivity,• Easy To Handle , Surgical Blade Sterile, Size 23 • Single Peel Pack In Metal Foil • The Tip Of The Blade Shall Be Well Defined, Central And Sharp. There Shall Be No Waviness, Jags, Feathers, Nicks, Or Other Defects On The Cutting Edge. The Surfaces Of The Blade Shall Be Smooth And Free From Tool Marks And Any Sign Of Corrosion. • Should Conform To Is 3319 , Sterile Hypodermic Syringe With Needle Attached, 22G, Single Use - 50 Ml • Clear Transparent Chamber • Prominent Graduation • Inert Material Gasket At The Piston To Minimise Friction During Movement & Prevent Leakage And Back Flow • Sharp Needle Ensuring Minimum Trauma During Penetration • Shall Conform To Is 12050 • Packing: Needle Should Be Attached With The Syringe And Packed In Unit Ribbon Pack • The Words Destroy After Single Use Or Equivalent Should Be Written On Unit Container. , Urethral Catheter 90 (Fg-14), Made Up Of Medical Grade Pvc , Urethral Catheter 91 (Fg-10), Made Up Of Medical Grade Pvc , List Of Lab Reagent & Consumable Iteam , Widal Test Kit , Dengue Combo Kit (Igg+Igm+Ns1) , Multiparameter Urine Strip Test (100) , Acetic Acid 500Ml , Test For Iodine In Salt , Water Testing By Strip Method H2s Test Kit Detection Of Salmonella And Citrobiter Bacteria From Water Sample , Filariasis Test Kit , Hcg Test Card , Malaria Rapid Test Card Pv/Pf , Hiv Fourdot , Hiv With Vdrl Comb Kit , Rapid Test Kit Syphillis Vdrl Test Card Igg/Igm/Iga , Temiphose 50% E.C. Lervicide 1 Ltr. , Pyrethrum 1 Ltr. , Uristis (Albuming & Sugar) (100) , Sputum For Afb Kit , K3 Edta With Vacuum 2Ml Double Cap , K3 Edta With Vacuum 4Ml Double Cap , K3 Edta With Vacuum 6Ml Double Cap , K3 Edta Paediatric Vial 0.5 Mi (Blood Collectio Tube) , K3 Edta Paediatric Vial 0.5 Mi (Blood Collectio Tube) , Vaccutainer With Vacuum 4Ml , Vaccutainer With Vacuum 6Ml , Gel + Clot Activator With Vacuum 3 Ml , Gel + Clot Activator Without Vacuum 3Ml , Sodium Fluoride Vial With Vacuum 4 Ml (Sugar) , Sodium Citrate 3.2 % 2 Ml (Blood Collection Tube Non-Vacuum) , Heaparin Vial With Vacuum 4Ml , Heaparin Vial Without Vacuum 4Ml , Plain Vial Screw Cap 5Ml , Vacuum Holder , Urine Container 50Ml With Cap , Micropipette 0.5-500Ul Calbration With Nabl , Megnifying Glass 80Mm , Falcon Centrofuge Tube 50 Ml (Sigma) , Xray-Film Size 12X15 (50 Film) , Xray-Film Size 12X12 (50 Film) , Xray-Film Size 8X10 (50 Film) , Xray-Film Size 10X12 (50 Film) , Di-Hl Digital Xray-Film Size 8X10 Fuzi (125 Film) , Di-Hl Digital Xray-Film Size 10X12 Fuzi (125 Film) , Di-Hl Digital Xray-Film Size 11X14 Fuzi (150 Film) , Di-Hl Digital Xray-Film Size 8X10 Care Stream (150 Film) , Di-Hl Digital Xray-Film Size 10X12 Care Stream (150 Film) , Di-Hl Digital Xray-Film Size 11X14care Stream (150 Film) , Di-Hl Digital Xray-Film Size 8X10 Konica Minolta (150 Film) , Di-Hl Digital Xray-Film Size 10X12 Konica Minolta (150 Film) , Di-Hl Digital Xray-Film Size 11X14 Konica Minolta (150 Film) , Hiv Iv Gen , Liesmens Stain Kit , Digital Bp Instrument Beurer/Accusure (Included - 1 Monitor, 2 Normal Cuff, 4Aa Batteries, User Manual, Type :- Upper Arm, Display - Lcd, Pulse Rate Indicatior, Memory Function, Movement Indicator, 90 Sets Of Memory, Measuring Time 5 Sec, Automatic Power Off, Warranty 1 Year, Measurment Method Oscillometric Method, Minimum Pressure Measurment Range 40 Mmhg, Upper Arm Circumference - 22-32 Cm , Mercury Sphygmomanometer (Bp Instrument) Diamond (Should Be Portable Mercurial Type, Isi Mark, Adult Arm Cuffs Of Size Medium, Large Andd Paediatric Cuff, , Stethoscope Adult With Paeditrict/Accusure (The Size Of An Adult Stethoscope Hear Is 45Mm, While A Pediatrict Head Is 35Mm, Stethoscopes Are Specificially Dual Heads Made For Stainless Steel) (High Quality Sound, Frequency Range 20 Hz-2000 Hz, Isi) , Digital Weight Machine Adult Beurer/Accusure (Material Glass, Lcd Display, Item Weight 180 Kg., The Scale Will Be Automatrically Truned Off After 16 Seconds, Balance Platform And Advance Step On Technology, Size 8 X10 Inch, Starting Weigth 7 Kg/15.4 Ib, Display 4 Digit Lcd, Power 3V Cr2032 Lithium Battery, Warranty 5 Year) , Digital Infant Baby Weight Scale 0-16 Kg./Accusure (Lcd Display, Measuring Range Up To Apporx 16 Kg, Reading Time Max 15 Seconds, Includes Removable Tray For Infant, All Vital Parts Made Of Rust Proof Materials) , Foetoscope (Aluminium) , Digital Salter Weighing Machine Up To 35 Kg. , Guaze Cutting Sciossors Isi , Yellow Tip (1X1000) , Blue Tips (1X500) , Disposal Esr Tube , Wbc Fluid Bottale 500Ml , Jsb Stain Ist 500 Ml Bottle , Jsb Stain Iind 500Ml Bottle , Giemsa Stain 500 Ml Bottle , Urine Analyzer Qudx 100Pro Semi Automatic (Diasys)/Accusure , Lugol Iodine , Hepacard (Jaimitra) , Gram Stain Kit , Manuatox Test Kit 10 Tu , Mild Steel Delivery Bed, Acme1800x550x800mm Frame Work Made Of Rectangular & Square Ms Tubes Mounted On Pvc Stupms. Cushioned Top In 3 Sections, Capable Of Tilting For Obstetric & Gynaecological Use. Backrest, Seat & Leg Section Adjustable By Hand Lever. , Heavy Duty Iv Stand, Tm-Iv 50X50x200cm Telescoping Stainless Steel Pole Adjusts Form 73-99.5 Inch, When Fully Extended. Triple Channel Pumps. 2 Iv Polle , Medical Stand Steel Revolving Stool Ss Top, Four Leg , Crp Quantative Test Kit (Turbo) , Hcv Test Card , Leishmans Stain 500 Ml , Absolute Eosinophil Diluting Fluid 100 Ml , Cover Slipe , Solution Hno3 500 Ml , Solution Lugol Iodine 100 Ml , Hemospot Kit (50 Test) , Ra Test Kit 100 Test , Spirometer High Resolution Colour Tft Screen, Build In Thermal Arrey Printer, Digital Turrbine Flow Meter With High Accuracy,Fvc Svc And Mvv Test , Labour Table 3×5.5Ft 3 Folder Delivery Table With Foam Mettress, Made In 3 Sections Adjustable Back Rest And Leg Section With Lever Machnism To Variying Position Capble Titlting For Obstrict And Gynecological Use , Examination Table 2 Section Cushinoed Top Mild Steeel Eproxy Powder Coated Adjustable Back Rest By Hand Lever With Mattress , Jsb Stain 1St. , Jsb 2Nd , Neubar Chamber , Glass Beaker 100Ml , Gl Ass Beaker 500Ml , Aec Fuid 100Ml , Wbc Pipette , H B Meter , Hb Pipette Isi , Glass Slide , Disposable Esr Tube. , Bituminous Ct Tube Cbc Roll , Ecg Roll , Plate Cou T Fluid 500 Ml. , Giemsa Stain 500Ml , Edta Fuid 500Ml , Glass Slide (1X100) , Reticulocyte Fluid 500Ml , Blood Group Compelete Kit Abd Group , Semi Auto Urba Blood Total Protein Reagent Erba (5X50ml) , Semi Auto Urba Blood Serum Lipid Profile Erba (5X20ml) , Semi Auto Urba Blood Glucose Reagent Semi Auto Urba (2X200ml) , Semi Auto Urba Blood Urea Reagent Semi Auto Urba (5X20ml) , Semi Auto Urba Blood Bilibruine Ragent Semi Auto Urba (4X60ml) , Semi Auto Urba Blood Creatitine Reagent Semi Auto Urba (4X60ml) , Semi Auto Urba Blood Sgot Reagent Semi Auto Urba (5X20ml) , Semi Auto Urba Blood Sgpt Reagent Semi Auto Urba (5X20ml) , Semi Auto Urba Blood Alkaline Phospatase Semi Auto Urba (6X6ml) , Semi Auto Urba Blood Serum Uric Acid Semi Auto Urba (5X20ml) , Semi Auto Urba Blood Albumine Semi Auto Urba (5X50ml) , Semi Auto Urba Blood Cknac Reagent Semi Auto Urba (2X8ml) (2X1ml) , Semi Auto Urba Blood Ckmb Reagent Semi Auto Urba (2X8ml) (2X2ml) , Semi Auto Urba Blood Cholesterol Erba (5X20ml) , Semi Auto Urba Blood Triglyceriode Erba (5X20ml)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
27.
Defence #9618266 AOC
Tender For Comprehensive Maintenance Of B/R Works In Otm Accns Of Pocket B Including Md Accns On East Side Of Lehl Marg Of Under Ge (South) Binnaguri - Demolition of Brickwork built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions complete allas specified and as directed. 2 Material and Labour for brick work with Fly ash brick straight of curved on plan exc 6m mean radius built in CM (1:6) complete allas specified and as directed. 3 Ditto all per item no above but except brick 4 Material and Labour for Brick work with Fly ash bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete allas specified and as directed. 5 Taking down plaster in cement mortar on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with wateretc complete all as specified and directed by the Engr-in-charge. 6 M&Lfor 15 mm thick renderingon fair faces of brick work in cement mortar (1:6) andfinished the surfaceseven and smooth without using extra cementetc complete all as specified and directed by the Engr-in-charge. 7 M&L for 5mm thickrendering in CM (1:3) onconcrete surfaces as in ceilingandfinishing the surfaces even and smooth with out using extra cementetc complete all as specified and directed by the Engr-in-charge. 8 M&L for 20mm thick rendering on fair faces of brick work or concrete surfaces in two layers (10mm & 10mm) in cement mortar (1:4) and finished the surface evenand smooth with applying WPCetc complete all as specified and directed by the Engr-in-charge.(Note : WPC will be measured and paid separately) 9 Supply only liquid water proofing compound 10 Materials and labour forPreparation of new plastered surfaces of walls and applying three coats of white washcomplete all as specified and as directed. 11 Materials and labour for preparation of new plastered surfaces of wall and applying two coats of acrylic washable distemper over a coat of primer complete all as specified and as directed by the Engr-in-Charge 12 Materials and labour forPreparation of new plastered surfaces of ceiling and applying three coats of white washcomplete all as specified and as directed. 13 M&L preparation on new plastered surfaces of wall and applying two coats ofexterior grade weather coat paint over a coat of primercomplete all as specified and directed. 14 S & F 2mm thick wall care putty (in two layers)on wall/ceiling complete all as specified and as directed by Engineer-in-charge. 15 M&L forPreparation of old plastered surfaces and applying one coat of oil bound distemper on walls complete all as specified and as directed by the Engr-in-Charge. 16 M&L forPreparation of old plastered surfaces and applying one coat of exterior grade weather coat paintcomplete all as specified and directed. 17 M & L preparation of new surface & applying two coats of synthetic enamel paint over a coat of pink primer to wooden surfaces exc 10 cm girthall as specified and directed.. 18 M & L preparation of new surface & applying two coats of synthetic enamel paint over a coat of red oxide to steel surfaces exc 10 cm girthall as specified and directed.. 19 M&L forpreparation of old steel surfaces of any descriptionover 10 cm width or girth and applyingone coat of synthetic enamel paintcomplete all as specified and directed. 20 M&L forpreparation of old wooden surfaces of any descriptionover 10 cm width or girth and applyingone coat of synthetic enamel paintcomplete all as specified and directed. 21 Taking down chowkats or frame with shutter (without taking off shutters from the frame) exe 1.5 sqmn.exe 4 sqm each.complete all as specified and as directed by Engr-in-Charge. 22 Taking down chowkats or frame with shutter (without taking off shutters from the frame) n.exe 1.5 sqm each.complete all as specified and as directed by Engr-in-Charge. 23 Taking down shutter exe 1sqm and n.exe 2sqm each.complete all as specified and as directed by Engr-in-Charge. 24 Taking down shutter n exe 1sqm each.complete all as specified and as directed by Engr-in-Charge. 25 M & L for in repair Pressed steel frames of 125X60mm minimum 1 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixedcomplete all as specified 26 S & F 105 x 60 mm size Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, including finishes of disterub surfaces of wall etc, complete as specified 27 M & L PCC (1:3:6) type C1 as in holdfast block, coping, bedblock etc.complete all as specified and as directed by Engr-in-Charge. 28 S&F 30mmflush shutter, solid core construction, with block board core and plywood face panel, commercial type on both side etc complete all as specified and directed. 29 S&F of 30mm thick factory made Skeleton Shutter partly glazed and partly panelled i.e. upper panel will be wire mesh fitted externally in the clear space & lower panel will be plain colour PVC sheet 5mm thickcomplete all as specified and as directed. 30 S/F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top & bottom rails MS frame shall be covered with heat mould plain coloured PVC C channel having PVC sheet strip of 20mm width stuck inside with solvent cement all as specified and directed. 31 S&F of factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawingcomplete all as specified and as directed. 32 S&F Aluminium anodizedbarrel tower bolts, extruded section 200mm long. 33 S&F Aluminium anodized handles, D type, 150mm long. 34 S&F in aluminium sliding door bolt 300 mmlong, plate type, stove enamelled black, with bright bolt not less than 16mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate. 35 S&F Stainless steel butt hinges medium weight 150mm long for wooden door complete all as specified and directed. 36 S&F Stainless steel butt hinges medium weight 100mm long for PVC door complete all as specified and directed.. 37 S&F Aluminium anodizedbarrel tower bolts, extruded section 150mm long. 38 S&F Aluminium anodized handles, D type, 125mm long 39 S&F Powder coated aluminiumsliding windows for three track with rubber gasket, stopperpowder coated aluminium standard beads/glazing clips ,locking arrangement etc and aluminium frame of size 80mmX25mmX1.55mm andshutter of section 20mm X20mm X1.55mm incl ( two shutter of 4.8mm thick glass and one shutter of wiremesh 0.36 mm dia of wire and average width of aperture 1.40 mm) including taking down old steel windows with necessary all fittings complete all as per manufacturers instructions and all as specified and as directed by the Engr-in-Charge. 40 S&F Powder coated aluminium louvered ventilators of size n exc 0.50 Sqm area with glass louvers, without sash bars of aluminium sections weighing not less than 0.605kg/m for frame of size 40x20x2mm including necessary jointing cleats, glazingcleats, rubber packing , anodised aluminium snap beading,screws, anodised aluminium fittings and 5.5mm thick tinted glass fixed in panels with suitable locking arrangementsincluding taking down of old existing steel ventilator and making good disturbed surface of wall complete all as specified and as directed. 41 S&F in repairs power coated aluminium door shutter fixed including roller machinewith rubber gasket, stopper, cleats, handlesetc complete incl aluminium door styles of size 80 mm x 38 mm x 2.00 mm and aluminium doorsection of top, bottom and lock rail shutter frame of 80 mm x 38mm x 2.00 mm taking down old door with necessary all fittingand all necessary fittinngs complete all as specified and as directed by the Engr-in-Charge. 42 S&F in repairpower coated aluminium Partition wall of framesize 80mm x 38mm x 2.00 mmwithstandard beads/glazing clips, locking arrangement etcwith necessary all fittings complete all as per manufacturers instructions and all as specified and as directed by the Engr-in-Charge. 43 S&F 4.8 mmplain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area of glass not exc 0.5 sqm each pane. 44 M&L9 mm thick prelaminated partilce boards interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screw to timber frame for pelmet boxes,aluminium door and aluminium partitionscomplete al as specified. 45 Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets. 46 M&L for suspended false ceilling system using metalic exposed suspende system, grid section size 600mm x 600mm comprising of GI powder coatedmain runner of dimension 39 mm x 24mm x 0.80mm thick ( thicknesscomprising of GI/0.4+ PPPCGS/0.3mm & weight of Runner 1.35 kg for 3600mm length) Cross Tee of dimensions 29mm X 24mm x 0.8 mm thick wall angle 22.2mm x22.2mm x 0.65 mm thick ( thicknesscomprising of GI/0.35 + PPPCGS/0.3 mm & Weight of angle 0.70 kg for 3050 mm length) withand including 6 mm thick designed prepainted calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid ( placed in the grid system duly suspended with 4 mm dia G I bars hangers fixed with steel dash through fastenersfrom purlins of the roof with necessary fittings and fixtures etc complete all as directed. 47 M&L for 10 mm thick Gypsum board false ceiling joint less work including application of putty over gypsum board to achieve smooth and joint less celing surface and applying two coat of oil bound distemper in ceiling surfaces including framed work forconsisting of 60 mm wide GI steel C section of as in main of 0.71mm thick and 60 mm GI channel section as in cross member of 0.63 mm thick and GI steel angle section as in suspenders of size 25x20x0.63 mm and wire cloth of 0.71 mm dia of wire and 100x50mm aperature size including cutting , riveting, steel fastener, drilling holes in RCC roof and securing with screws etc complete all as specified and directed by Engineer-in-Charge. 48 M&LPOP cornice width n.exc 200mm wide in ceiling edge of any design and shape ,complete all as specified and directed by Engineer-in-Charge 49 S&F hollow PVC Wall panneling with designed/printed panels having wide of 300mm including necessary caping/fillets at top, bottom and junctions/corners of wall where ever required as per site etc complete all as per specified and directed. 50 S & F WPC louvers wallpanneling (profile sheet) width varies from 10mm to 17mm and width varies from 150mm to 300mm inclusive of necessary fittings,fixtures, grids and capping/fillets reuired at site as per manufacture specifications etc complete all as spefied & directed etc complete all as specified and directed. Make-Rajshree or equivalent. Note: The size, pattern and colour of WPC louvers panneling shall be approved by Engineer-in-charge. 51 Supply & fix framed work such as grills, gratings, etc., with ends of bars shouldered and/or riv-eted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe 390 Gde E-165 including taking down old wrought iron or mild steelcompleteall as directed by the Engr-in-Charge. 52 S&Ffor CP curtain rod 25mm diaandwith brackets,knobs etc complete including taking out old one,the type portion and size of curtain rod shall be approved by Engr-in-Charge. Note: The size and partern of curtain rod shall be approved by Engr-in-charge. 53 Supply and fixing in repairs stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of apperture 1.40 mm and fixed with stainless steel staples in steel/wooden/aluminium frames completeall as specified and as directed by the Engr-in-Charge. 54 Hacking out old/broken glass (any description, size and quality) upto 12 storied bldg complete all asspecified and as directed 55 Supply and fixing for 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty insquareexe 0.50 Sqm in each pane complete all as specified and as directed by the Engr-in-Charge.upto 12 storied bldg. 56 Supply and fixing for 4mm thick figured glass, ordinary quality and glazing with oil putty insquaren .exe 0.50 Sqm in each pane upto 12 storied bldg complete all as specified and as directed by the Engr-in-Charge. 57 Dismantling of floor hearth or wall tiling incl cement mortar bedding ( but not backing) and removing debris and rubbish off the premises. 58 M&L forvitrified ceramic coloured tiles 8-9mm thick (square /rectangular ) polished area of each tiles not exceeding 0.36 sqm as in skirting/dado etc. set and jointed in neet cement slurry and pointed white or coloured cement to match the shade of the tiles laid over and including 15mm thick screed bed in CM (1:6) etc complete all as specified and directed . 59 M&L forvitrified ceramic coloured tiles 8-9mm thick (square /rectangular ) polished area of each tiles not exceeding 0.36 sqm as in skirting etc. set and jointed in neet cement slurry and pointed white or coloured cement to match the shade of the tiles laid over and including 10mm thick cement plaster in CM (1:4) for backing coat complete all as specified and directed . 60 M & L for double charge Vitrified Ceramic tiles light shade 8 to 9 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm as flooring with border of dark shed,over and including 15mm thick screed bed in CM (1:6)set and jointed in neat cement slurry and pointed in white or coloured cement to match in white or coloured cement to match etc complete in all respect as specified. 61 M & L for double charge Vitrified Ceramic tiles in skirting light shade 8 to 9 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm , in skirting and dado over and including backing coat in CM (1:6)set and jointed in neat cement slurry and pointed in white or coloured cement to match in white or coloured cement to matchetc completeall as specified. 62 Material and labour for Non-Skid ceramic coloured floor tiles as in floor 7 to8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floor etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles laid over and including 15mm thick cement screed bed in CM (1:6) complete all as specified and as directed by the Engr-in-Charge. 63 Material and labour for Non-Skid ceramic coloured floor tiles as in floor 7 to8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in skirting/dado etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles laid over and including 10mm thick rendering in CM (1:4) complete all as specified and as directed by the Engr-in-Charge. 64 Material and labour for Non-Skid ceramic coloured floor tiles as in floor 7 to8 mm thick (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm as in floor etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles laid over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed by the Engr-in-Charge. 65 Material and labour for Non-Skid ceramic coloured floor tiles as in floor 7 to8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in skirting/dado etc set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles laid over and including 10mm thick rendering in CM (1:4) complete all as specified and as directed by the Engr-in-Charge. 66 M&L for glazed colouredceramic tiles (300x450x7mm thick)on vertical surfaces such as skirting/dado set and jointed in neat cement slurry pointed in white or coloured cement to match over 15mm thick rendering in CM(1:4) all as specified and directed by Engr-in-charge. 67 S & F in repair vitreous china squatting pan of orissa pattern long pan of size 580 mm x 440mm with integral foot rest white with cast iron P or S trap with back inlet includingflush pipe of suitable length to connection with existing cistern & make good complete all as specified and as directed by Engineer-in-Charge.(Make : CERA or Euivalent) 68 S&F in repairs, vitreous china wash down water closet pan, (pedestal pattern) white, including P or S trap and withplastic water closet seat cover white, closed pattern with flat bottom, andcover and mild steel chromium plated or aluminised hinging device etc complete.(Make : CERA or Euivalent) 69 S&F in repair PVC seat cover for pedestal pan, white closed pattern with flat bottom and cover and mild steel chromium plated or aluminiumisedhanging device complete all as directed.(Make : CERA or Euivalent) 70 Supply and fixing in repair cascade type vitreous china white wash down water closet P or S type wall hung with flushing cistern, hush seat cover and internal fittings complete with fixing bolts and making all necessary connections complete all as specified and directed by Engr-in-Charge.(Make : CERA or Euivalent) 71 S&F in repairCP health faucet (ABS body)mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook in cluding making connections and fixed in position complete in all respect and specified (Make : ESSCO/Marc/Cera). 72 S&F in repair of PVC low level flushing cistern, 10 ltr capacity, syphonic action type white body with inlet ball valve, float , handle,bracket, longflush pipe of PVC to suit flushing cistern ( long bend) etc complete & connecting to WC (Make : Prayag or Euivalent) 73 Taking up or down 15mm bore steel water tubings and fittings etc complete and makinggood disturbed surfaces of walls/ceilings etc complete all as specified and as directedof following bore:- 74 Taking up or down 20mm bore steel water tubings and fittings etc complete and makinggood disturbed surfaces of walls/ceilings etc complete all as specified and as directedof following bore:- 75 M & L for 15mm steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor including cutting grooves in wall etc complete all as specified 76 M & L for 20mm steel tubing medium grade,galvanised fitting fixed complete to walls and ceiling or floor including cutting grooves in wall etc complete all as specified 77 Supply & fix in reapir Bib tapcast copper alloy, chromium plated with crutch or butterfly handle, screwed down for 15mm bore GI Pipe or for brass ferrule including taking down old unserviceable one. (Make : Prayag or Equivalent) 78 S&F in repair of pillars taps,fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, scewed for iron pipe 15 mm bore(Make : Prayag or Equivalent) 79 Supply & fixin repairangular stop cock made of brass chromium plated screwed both ends for iron pipe for 15mm bore complete all as directed by the Engr-in-Charge. (Make : Prayag or Equivalent) 80 S&F in repairs for 15 mm bore stop cocks fancy type, chromium plated reduce body, long shank, cap (concealed type) screwed down high pressure screwed both ends for iron pipe or for union etc as in repair. (Make : Prayag or Equivalent) 81 S&F in repair ofswivel shower of CP with shower arm 150 mm size for fixing with 15 mm bore GI pipe complete all as specified and as directed. (Make : Prayag or Equivalent) 82 S&F in repair of PVC connections 15 mm size with PTMT nuts of length 600 mm.pipe(Make : Prayag or Equivalent) 83 S & F stainless steel soap dish best quality fixed to plugs with chromium plated brass complete all as specified and directed (Make : Prayag or Equivalent) 84 S&F in repairtubular towel rail 20mm dia D type, Brass Chromium Plated 60 cm long between flanges. (Make : Prayag or Equivalent) 85 S&F in repairSS Towel rack fixed to wall with necessary fittings/fixtures etc complete all as specified and directed. (Make : Prayag or Equivalent) 86 S&F in repair 600 x 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plug with chromium plated brass screws & cup washers. (Make : Prayag or Equivalent) 87 S&F in repair corner glass shelf 300mm size with brass brackets fixed to wall with necessary fittings/fixtures etc complete all as specified and directed. (Make : Prayag or Euivalent) 88 S&F in repair Front glass shelf 500 x 125mm sizefixed to wall with necessary fittings/fixtures etc complete all as specified and directed. (Make : Prayag or Euivalent) 89 Supply and fix in repair stainless steel kitchen plate rack of size 31x30x10and 1 mm thick specified and directed by the Engr-in-Charge. (Make- Pryag or Euivalent) 90 S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm and including 32mm waste coupling of PTMT (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) (Make- Pryag or Equivalent) 91 S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm and including 32mm waste coupling of PTMT (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms) (Make- Pryag or Euivalent) 92 S & F in repairs 500 ltrs rotational moulded polyethelene water storage tanks (cyclindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed. 93 S&F in repairs 1000 litres capacity rotational moulded polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I with and including 25mm bore dia Ball brass valves, high pressure, with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed etc complete all as directed. 94 S&F in repairfor PVC (SWR) (Bore of pipe 110mm) pipes single socketed, in any length with rubber ring joints fixed to walls/floors with necessary clamps, bolts etc complete all as directed by Engr-in-Charge. 95 S&F in repairfor PVC (SWR) bends any radius fixed to PVC Pipes/Steel Gutters etc complete all as directed by Engr-in-Charge (Bore of pipe 110mm) 96 S&F in repair for PVC (SWR) vent cowl fixed to PVC Pipes etc complete all as directed by Engr-in-Charge (Bore of pipe 110mm) 97 Receivingday to day routine complaint slips of petty nature of B/R complaints for Plumber of Sanitary,Internal water supply and carpenter for Joinery & Glazings etc as issued by MES Rep from sub Division ( Complaint Cell) of South Zone Binnaguri under GE (S) Binnaguri including detection of fault and rectify/repair the same to maintain the internal water supply services,Plumbing, Joinery etc services smoothly and depositing the complaint slip back duly signed by Users and MES Rep for satisfactorily attending the complaints complete all as specified and as directed.Note - (i) Quoted rates shall deemed to be included for detecting fault including minor additions and alterations and materials in existing buildings as required to make the same serviceable fixed at the same place or other as directed at site. (ii) Complaint slip shall be provided by the contractor duly printed with CA No & Name of firm as per format given by Engr in Charge and the cost shall be deemed to be included in quoted rates. (Note :-In absence of the MES Rep payment will not be allowed during running/Final payment.)(iii)All necessary tools & plants i.e. Carpentars Saw, spanner set, wrench, screw driver set, drilling machine, bomboo/aluminium ladder, crimping tool, cuttuing plier etc shall have to be provided by contractor at his own cost.(iv) In case of any accident/mishapenning occurred during the repair/replacement of work shall be responsibity of Contractor. (v)The works are not falling under minor repair shall be paid shall be measured and paid separately under respective items of BoQ.
Contract Date: Feb 19, 2026 Contract Value : 41.20 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
28.
Defence #9549440 AOC
Bids Are Invited For Eamp 2026 Work Of Ins Mormugao; 1 COOKING RANGE, HOT PLATES 2 Remove hot plates & drip trays and clean them properly 3 Remove hot plates bearers and Mild steel using heat resisting paint. Re-fix hot plates & drip trays on completion of the work and ensure they are fixed properly 4 Remove both side screens and bottom cover of Ovens. Clean inside thoroughly and ensure all elements are fixed properly in their places 5 Clean and check properly Thermostat, bulb and ensure that they are in order 6 Check performance of ranges and undertake necessary repairs 7 MILLING MACHINE 8 Check performance of machine and make necessary repairs and adjustments 9 AUXILIARY MOTORS (Model: Below 10 KW) 10 Decoupling of motor from pump, removal of motor from first connection and lifting of motor from foundation 11 Shafting of motor from ship to firm’s premises 12 Dismantling of motor and submission of material condition assessment report within 2 hrs for establishment of scope of work 13 Replacement of bearings (inclusive of cost of grease, oil/lip seal, nuts & bolts etc) 14 Repairs of bearing holder/bearing cap 15 Dynamic balancing of rotor 16 Repairs of rotor shaft including shaft trueness checks 17 Rewinding of stator (includes cost of winding wire, varnish, lugs, ebonite/Bakelite sheets, thermistor, stator insulation material, fasteners, oil/lip seals, washer joints etc) 18 Repairs of terminal box 19 Repairs of cooling fan 20 Repairs of foundation stool 21 Boxing up and trials of motor at firm workshop 22 Shifting of motor from firm’s premises to ship for fitment 23 Fitment of motor at location and proving of trials onboard with SS and FMU Rep. 24 Alignment and coupling of pump and motor assembly insitu 25 CO2 FF SYSTEM 26 Check weight of each cylinder. If any cylinder shows loss of gas exceeding 10% of its content, it must be removed for recharging. Note:- Alternately use Portable Ultrasonic Level Detectors for undertaking this routine 27 Calibrate all gauges in the system and issue certificates for NABL accredited laboratory 28 Admit LP air into ring main checking the system for leaks. Ensure that all the discharge pipes and nozzles are clear. 29 INHIBITOR SYSTEM 30 Check all QOVs by operating with Pyro. Dismantle and overhaul 50% of QOVs. The whole checks to be completed in two successive refits. 31 Check integrity of the system. Check all joints for tightness. Renew gaskets if required. Pressure test the system after repair. Rectify defects, if any. 32 Examine all fittings and pipes for damage. Refit/repair as necessary 33 Check and ensure proper insulation of special alloy flanges and sleeve joints. Replace insulating bushes and gaskets if necessary 34 Check ohmic resistance of all squib bridges for guaranteed value and serviceable conditions (from 0.6 to 1.2 ohms). Note:- Direct current not to exceed 0.05A when carrying out SR-4 35 Check integrity/ leakages of all stop check valves and refit if require 36 Carry out the following:-(a) Repairs of defective sensors/ pressure relays / gauges.(b) Calibration of all sensors, pressure relays, gauges and DOZOR Control Cards (including SPTA) at shop floor (DOSSRR). Replace the defective ones. 37 Joint Pressure Testing of overhauled QOVs at shop floor. 38 Joint Certification of entire quick spraying line from the check valve to the sprinklers by SS/Maintainer and rep of Refitting Authority 39 Post fitment of all components, carry out Integrated Test of Joint Operation of APZ 028 / KARAT-M / KRAB / Sprinkling systems as per operation Manual, except operation of pyros and inhibitor system. 40 Overhaul defective bottle head assembly valves. Post overhauling, pressure test the bottle along with assembly. 41 PORTABLE SUBMERSIBLE PUMP 42 Capacity trials to be carried out and defects observed to be rectified 43 Check level and condition of oil in seal package. Renew seal package if oil is emulsified. 44 STP/VTS 45 Overhaul of OBD pump including replacement of 01 mechanical seal E6039D-000667 (04 No) 46 Overhaul of OBD motor including rewinding and replacement of bearings (04 No) 47 Overhaul of mixing and draining pump including replacement of 01 mechanical seal EH6039D-000937 (02 No) 48 Overhaul of mixing and draining motor including rewinding and replacement if bearing (02) 49 Overhaul of macerator pump including replacement of 01 mechanical seal EH6039D-001409 (02 No) 50 Overhaul of macerator motor including rewinding and replacement of bearing (02) 51 DR on whirl container 52 Calibration of pressure gauge (10 No) 53 Cleaning of STP pipeline (50 Mtr) 54 Renewal of pipeline and proving of leak test (50 Mtr) 55 Effluent test of STP (02 No) 56 DR on Control pannel 57 Overhaul of valves (10 No) 58 Replacement of float switch EH6039D-000338 (06 No) 59 Replacement of Tie Bolts M10X450/80/80 9520K (10 No) 60 Modification of VSS pipe and to be done at AFT SS WC bathroom, AFT JS WC bathroom, Passageway 13, Passageway 14 including Piping & Fittings 61 SERVICES (Vide HQWNC fax 300/50/9/69 dated 08 Jul 25) 62 Fitment of 50mm vacuum line and removal of 40mm soil line 63 Welding of flanges for fitment of isolating valve in vacuum line 64 Degutting and regutting of SS panel in JS/ SSWC 65 Cutting of main WT section for passing vacuum pipeline 66 Approximately 540 man-days would be required to undertake the modifications 67 SPARES (Vide HQWNC fax 300/50/9/69 dated 08 Jul 25) 68 GI pipe 50mm SCH 40 69 GI pipe 40mm SCH 40 70 GI pipe 12.5mm SCH 40 71 SS 316 Ball Valve 50mm 72 SS 316 Ball Valve 12.5mm 73 GI Flange 50mm 74 GL Elbow 90’50mm 75 GL Elbow 40’50mm 76 GI TEE 50mm 77 GI reducer 50mm*40mm 78 MS Cooler plate 79 GI C Clamp 50mm 80 GI Barrel Nipple 12.5mm 81 Gasket Neoprene 3mm 82 Gasket Neoprane 2mm*50mm 83 SS 316 Nut bolts with SS washer M16*60mm 84 SS 316 Nut bolts with SS washer M16*50mm 85 DOORS NWT 86 Check clips, hinges for looseness, locking arrangement and any other components for wear and damage and undertake necessary repairs 87 Examine condition of rubber gaskets, door structure and kick out panel and undertake necessary repairs 88 APT 89 Providing of APT in presence of User Dept and Ship Staff. Test parameters involve building up 150 mm pressure drop restricted below 13 mm in 10 minutes/ as prescribed in last report. Calibrated U-tube manometers are to be used. Suitable air pressure and air flow rate generation devices to be arranges by the firm for the test. Acceptance Agency. APT will be offered to external agency, Hull inspection and Trials Unit, Mumbai (HITU) for acceptance. 90 Renewal of rubber beading of WT/GT doors 91 Renewal of rubber beading of WT/GT hatches 92 Structural repairs on WT/GT doors and hatches 93 Removal, repairs/ renewal and fitment of SOQC valves 94 Removal, repairs/ renewal and fitment of WT sluice valves-Removal, Overhauling, refitment, including relacing deamaged/ missing valve wheels and flaps opening of removed valves on trunking to be temporarily blanked for APT 95 Overhauling of mushroom heads ventilation flaps-removal, overhauling, refitme including replacing damaged/ missing valve wheels and flaps opening of removed valves on trunking to be temporaily blanked for apt 96 Packing of cable glands and cable conduits – Rectification of all additional defects precluding proving of APT (including air leaks from glands/ joints/ deck conduit, rubbber coaming etc.). Packing and sealing with sealant, araldite and hardener to prove WT integrity 97 Removal, repairs/ renewal and fitment of Rectangular Ventilation Trunkings – Rectification of all additional defects precluding proving of APT. 98 Manufacture of blanks for blanking and seaming of pipes – Rectification of all additional defects precluding APT (Including air leaks from glands/ joints/ deck conduits/ rubber coaming etc.). Blanking and sealing of pipes to prove WT integrity of compartment. 99 Build up weld seam and pitted surface on decks and bulkheads. 100 Removal and fitment of bulkhead, deckhead and ship’s side covering MFMB lagging/ cladding/ panels/ acoustic panels to provide access to bare metal for conduct of APT and identification of leaks. The items removed are to be replaced on clearance. MFMB sheets for lagging to provide by the firm. 101 Renewal of deck plates in way of APT MS 102 INCINERATOR 103 Carry out cleaning of filters in diesel oil pump and diesel oil supply line (Task 14 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 104 Carry out the replacement rubber stator on sludge oil dosage pump. (Task 15 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 105 Carry out the inspection/ repair of sludge dosage pump rotor for surface smoothness. (Task 16 of Regular Maintenance Procedures of instruction manual for Incinerator OG200 relevant). 106 Carry out greasing of flue gas fan bearing. (Task 17 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 107 Visually inspect the thermocoulpe of combustion chamber. (Task 18 of Regular Maintenance Procedures of instructional manual for incinerator OG200 relevant). 108 Carry out the lubrication of sluice bearings. (Task 19 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 109 Carry out the lubrication of door hinges. (Task 20 of Regular Maintenance Procedures of instructional manual for incinerator OG200 relevant) 110 Check the door gasket by using chalk on the edges of the door opening. Close the door. Open and check that the door gasket had contact with the edge all the way around the opening. If not adjust the door. (Task 21 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 111 Carry out cleaning of inside of inspection/repair hatch with steam or hot water. (Task 22 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 112 Carry out the inspection/repair of Paint work for scratches. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 113 Check the control and alarm system according to “Test of function and safety devices”. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 114 Check all safety devices and calibrate if necessary. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 115 Check all valves, pumps and solenoid valves for leakages. Repair if necessary. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 116 Replace nozzles for diesel oil burner with new ones. (Task 8 of Regular Maintenance Procedures of instructional manual for Incinerator OG200 relevant). 117 COLD LAGGING 118 Carry out cold lagging on pipelines (1 in-10 in) 119 Carry out cold lagging on flanges (1 in-10 in) 120 Carry out cold lagging on heat exchangers 121 De-gutting of lagging 122 Lagging insulation material 123 SINGLE ARM DAVIT 124 Carry out SPM checks of electric motor. Lubricate/ replace bearings as necessary 125 Open winch gearing and examine for any evidence of excessive wear or defect 126 Dismantle turning out mechanism from the bevel gear box, bottle screw, grub screw and examine the condition of thrust bearings, sleeves, grub screws for sign of corrosion and wear. Repair/ renew as necessary. Fit back and charge with fresh grease. 127 Examine for corrosion, distortion or other defects paying particular attention to inside surface of davit stand. Check whether paint is cracked, blistered, badly adhering, excessively coated or corrosion is evident. Raise specific defect to dockyard for rectification. Area to be cleaned to bare metal, thoroughly dried and re-preserved 128 HELICOPTER INFLIGHT REFUELING SYSTEM (HIFR) 129 Replace all HIFR hoses 130 H2S SENSOR 131 Calibration/ serviceability checks of Fixed H2S gas detection system. 132 Calibration/ repairs of Hand held gas detectors. 133 CCTV 134 Liquidate defects in CCTV cameras 135 DR on controls and monitoring stations 136 Cabling and wiring as required 137 EMERGENCY ESCAPE SCUTTLES & HATCHES 138 SERVICES 139 Check clips, closing mechanism, hinges for looseness, spring mechanism and wedge pieces/ for signs of wear. 140 Examine neoprene/ teflon washers, toroidal sealing rings and rubber sealings. 141 Raise specific defects to dockyard for repairs. 142 Carry out watertight integrity test of all W.T. hatches using Ultrasonic Leak Detector (ULD) device. 143 Identify the leakage through watertight seals with the help of Ultrasonic Leak Detector and raise specific defects to yard for rectification if any. 144 HATCHES 145 Check clips, closing mechanism, hinges for looseness, spring mechanism and wedge pieces/ for signs of wear. Examine neoprene/ teflon washers, torodial sealing rings and rubber sealings. Raise specific defects to dockyard for repairs. 146 Carry out watertight integrity test of all W.T. hatches using Ultrasonic Leak Detector (ULD) device. Identify the leakage through watertight seals with the help of Ultrasonic Leak Detector and raise specific defects to yard for rectification, if any. 147 Check for any damage on metallic rubber coaming and repair if found damage. 148 WINDOWS & MANHOLES 149 MANHOLES 150 Check clips, closing mechanism, hinges for looseness, spring mechanism and wedge pieces/ for signs of wear. Examine neoprene/ teflon washers, torodial sealing rings and rubber sealings. Raise specific defects to dockyard for repairs. 151 Carry out watertight integrity test of all W.T. hatches using Ultrasonic Leak Detector (ULD) device. Identify the leakage through watertight seals with the help of Ultrasonic Leak Detector and raise specific defects to yard for rectification, if any. 152 WINDOWS 153 Check hinge fitting, toughened glass and glass rails for looseness and sign of wear / damage. Raise specific defects to dockyard for repair/ renewal. 154 RAIL LESS HELO TRAVERSE SYSTEM (RLHTS) 155 Undertaking of routine maintenance/ overhauling/ defect rectification of Rail Less Helo Traverse System (RLHTS) 156 Hydraulic winch and wire rope (Port, Stbd & Aft) 157 Hydraulic power pack (Port, Stbd & Aft) 158 Hydraulic pipes and control valves (Port, Stbd & Aft) 159 Control panel and cabling (Common) 160 FWD CENTRIFUGE 1, 2 & 3 161 Check Threads of inlet pipe of oil pairing disc for damage and wear. Renew of required 162 Check flow indicator if clogged 163 Check the reducing valves cones for scratches and play. Renew if required. 164 check the non return valves cones for scratches and play. Renew if required. 165 Dismantle and examine separator bowl assembly thoroughly. Clean all components and check following:-(i) Check disc stack pressure(ii)Check for erosion, corrosion and cracks(iii) Galling of guide surface 166 Renew oil in gear housing. Check the teeth of worm wheel and worm gear. Renew if required. 167 Carry all routines listed in intermediate service 168 Check height position for pairing disc for MAB206 type separators. 169 HORIZONTAL DRIVE(a) Check axial play of coupling disc.(b) Renew bearings of worm wheel shaft. 170 VERTICAL DRIVE(a) Clean and check bowl spindle and name for impact marks.(b) Check radial wobble of bowl spindle.(c) Clean and check buffer and ball bearings housing. Renew if required.(d) Renew ball bearings and top bearings springs. 171 Clean and check break shoe. Renew friction pads/ break plug. 172 Clean and check friction coupling. Renew friction pads and lip seal ring. 173 Dismantle pump assembly. Clean and check bushings, wear gaskets coupling, relief/safety valve and impeller shaft. Renew lipseal ring. 174 Renew frame fit rubber cushions / vibration dampers.
Contract Date: Ref. Documents Contract Value : 3.13 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
29.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
30.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
31.
Defence #9528620 AOC
Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the rate shall be quoted by the bidder. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units including indoor and outdoor unit complete of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 BLANK 24 BLANK 25 BLANK 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 100 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 400 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No.(iii) Aluminium Bus bar TPN - 600 amps- 1setOUTGOING(i) MCCB 3 Pole 200 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release- 02 No.(iii) MCB TPN 32 Amp - 03 Nos.(iv) 80 HP S/D soft STARTER- 02 Nos.(v) DOL STARTER 7.5 HP- 02 Nos.(vi) Motor Protection Relay32-88 amps- 2 nos. (vii) Motor Protection Relay2- 5.5 amps- 2 nos. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 4 Nos. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply and fixing single unit flame type detectors (Triple IR infrared flame detectors) Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relaying type module) complete all as specified and directed 78 Supply and fixing,Test and Drain valve 65/50mm, forged brass body, brass chrome plated ball, 304SS stem with Polycarbonate sight glass, indicator and handle made of steel complete all as specified and directed 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Double mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on rails at the bottom to traverse the length of the storage system. Top rails mounted on the racking system shall also support it. PMDC motars should be used with required counter weight for better efficiency of verticle travel.General technical parameters of stacker crane:Technical parameters/Type- Double Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system:- Two single aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelDouble mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system during the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASR system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1)Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane. An additional antifall device must be provided for the lifting carriage. In the event of electromagnetic break motor failure or malfunction, this device should automatically engage to safely hold the carriage and prevent any freefall, thereby avoid accidents due to emergency brake failure.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASR system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: 1) Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integrated. Changes in make of different components of ASR system and minor changes in different parameters are permitted with approval of Accepting Officer as per recommendation of ASR system manufacturerprovidedthe end objective of the system is complied.2) The ASR system is to be installed in Bulk store house complex. Necessary civil works for installation of the ASRS required in the building is included in the scope of this item. Neccessary arrangements for integration of system with flooring and overhead trussess of the building shall be done at appropriate stage and shall be included in the rates quoted3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptanceMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advanced Inventory Management System with compatibile computer hardware and integrated inventory and weight management system with PLC based software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height(Min) : 6400 (±100) mm(ii) System Width(Min) : 3150 (±100) mm(iii) System Depth(Min) : 2300 (±100) mm(iv) System Base(Min) : 7.24 Sq.Mtr(v) Tray Int. Size(Min): 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight(Min) - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 Kg(Min)Technical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(Min)(x) Storage surface area per system - 39.2 sq mtr(Min)(xi) Door - Automatic, (xii)Power supply - 440V, 50/60 Hz, 3 Phase(xiii) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xiv) Chain - Diamond makeor equivalent, (xv)Bearing - SKF/NTN make or equivalent(xvi) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: 1) The system and software provided under this item shall be of same make as for item 13.066 to 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system.2) Comprehensive maintenance of the system during two years of defect liability period shall be a part of this item and rates shall be quoted accordingly. Comprehensive maintenance shall include all spares including software update. The ASR and advanced management system shall be operated by single warehouse management system.3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptance 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS, 100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCB, TPN 40 Amp, 415 Volt, C Curve - 03 Nos.(b) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(c) Digital ammeter - 2nos.(d) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV / 0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro/Bajaj 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing and commissioning of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 MMake: Precitech thermal Pvt. Ltd., Rram Buisiness corp, Alfa therm Ltd., Thermax Ltd, Kanti Industries, Fortec 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories: Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(b) Radiator with blower fan or heat exchanger with guard.(c) Pipe coupling for engine cooling system piping.(d ) Corrosion inhibitor coolant(e) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(f) Fly wheel housing and fly wheel to suit alternator.(g) Engine bearing mechanism in fly wheel housing.(h) Shut off coil with safeties for LLOP/HWT/over speed.(i) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Battery charging alternator.(m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of30 gauge for the entire length of exhaust pipe.(o) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(p) Interconnecting copper cabling of adequate capacity batteries control.(q ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(r) Self starter 24 volts DC.(s) Electric operated electronic governor.(t) Fuel injection pump.(u) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(v) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (w) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(x) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(y) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling for exterior canopy (without opening its panel) etc complete all as specified and directed.(z) Isolator panel with 630 amp MCCB(aa) Auto logic panel for automatic stat(ab) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof, insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(ac) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(ad) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (ae) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(af) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No. EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(i) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(ii) Bottom gland plate for incoming and outgoing cables.(iii) Circuit diagram plate.Note:- DG set should be as per CPCB- 4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.The contractor shall procure the item within the period given by CPBC in case of revision in CBPC norms. Nothing extra will be paid on account of delay from the part of contractor. DG set shall have an exhaust with stack height of minimum 2m from the top of generator with a cowl. Smoke released from the exhaust of the DG sets indicating that emission parameters are within permissible limits, as prescribed by CPCB, demonstrating compliance with emission limits prescribed by CPCB 2016. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 set(d) Horizontal aluminium bus bar for 3 phase 440 V, 50 Hz, 4 wire system of rating 800 Amps for phases and 800 Amps for neutralOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 03 No. (for Package AC Bulk Store, pump house and fire pump & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The Energy Meter to be capable of running in both prepaid and postpaid mode.(b) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 155 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Initial load test (pull outtest as per design load) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 158 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 159 Testing of piles Initial load test (verticle load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed 160 M & L for carrying out Initial Load test (lateral load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note:- Providing and installing test piles shall measured and paid separately) 161 M & L for carrying out Initial load test (pull outtest as per design load)of cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 162 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
Contract Date: Feb 11, 2026 Contract Value : 59.27 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
32.
Defence #9528618 AOC
Tender For Special Repairs To Bldg No. 63 For Agniveervayu (Women) At 3 Brd Under Ge (Af) Mc Chandigarh; 1 Demolition of un-reinforced cement concrete exc 15cm thick on any description and in any positionnot other wise specially provided for and removing all demolished material/debris to 1.50Km form the site and depositing where directed complete all as specified and directed. 2 M&L for Plain cement concrete 1:7:12 , Type F2 (using 40mm graded brick aggregate)as in sunken filling and mass concrete complete all as specified and directed. 3 M&L for providing water proofing treatment of sunken portion of WCs, bathroom etc. by applying cement slurry mixed with Acrylic based polymer modified cementitious composite compound coating of make as approval in Technical Instruction 5/2003 by adding :(a) 15mm thick plaster (1:4) cement sand mortar mixed with and including liquid water proofing compound @200ml per 50Kg bag by weight of cement on floor and wall / beam , finishing the surface even and smooth without using extra cement. The surface shall then be cured and allowedto dry. (Note: Water proofing compound shall be measured and paid separately). (b) First layer of slurry of cement @0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hrs.(c) Second layer of slurryof cement @0.242 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hrs followed with water curing for 48 hrs and including demolition of existing treatment or flooring and removal of all rubbish outside defence land upto a distance exc 1.5Km but n.exc 5Km, complete all as specified and directed. 4 M&L for Plain cement concrete 1:3:6 , Type C1 (using 20mm gradedcrushed stone aggregate)as in sub base of floorscomplete all as specified. 5 Material and labour for cleaning and removal of dust,mud,algae,moss and other stains from roof tiles(brick/concrete) and parapetwith help of wire brush or mechanical means including scrubbing down with water. removal of all rubbish outside the defence land, complete all as specified and directed.Note:-Ensuring no damage to solar panel plate/arrangement fixed on roof. 6 Material and labour for brushing neat cement slurry with 3.00 kg of cement per square meter complete all as specified and directed.Note:- Ensuring no damage to solar panel plate/arrangement fixed on roof. 7 Material and labour for rendering20mm thick in cement mortar (1:3) usingWPC @ 200ML per 50Kg bag of cementon surfaces of roof and parapet, finished even & fair without using extra cement, Ensuring no damage to solar panel plate/ arrangement fixed on roof, complete all as specified and directed. Note :-WPC shall be measured and paid separately. 8 Supply only Liquid water proofing compound complete all as specified and directed by Engineer-in-charge. 9 M & L for providing,mixing and applying Dr.fixit/Fosroc/Asian Primer AC with 10% water dilution with clean portable water,and applying with roller or brush coverage at the rate 7.0 to 8.0 sqm per litre/coat, allow the primer to dry for 04 hrs. And applying a coat of Dr.fixit/Fosroc roof seal select (diluted with water in the ratio 2:1) self priming coat at the rate 8-10 sqm/litre/coat in the SSD(Saturated surface Dry) condition.Apply 1st coat of Dr.fixit/Fosroc roof seal select at the rate of 0.45-0.5/litre/sqm/coat. Supply and Laying a 45 Gsm glass fibre mesh of 2.5mmX2.50mm sandwiched between the first and second coat.While the first coat is still wet. Allow the frist coat to dry for 4-6 hrs. Apply second coat of Dr.fixit/Fosroc roofseal select with the same application coverage.Application direction of second coat coat should be perpendicular to the first coat .Allow second coat to dry for 4-6 hrs.Apply third coat of Dr.fixit/Fosroc roofsealselect at an application direction that is perpendicular to that of the second coat with the same application coverage rate to achieve total dry film thichness of 900 to 1000 microns at forced coverage at the rate of 1.50-1.60 litre/sqm in 3 coats. Check to see no void surface is untreated/uncoated. Allow the system to air cure for 7 days minimum. The material havingfollowing technical properties: Attains a tesile strength with fibre N/mm 2=6-8 as per ASTM D 2370; Elongation at break = 200% as per ASTM D 2370, Crack bridging ability up to 2mm,Shore-A hardness 80 as per ASTM D2240-2015, Tear Resistance with fibre N/mm 34 as per ASTM D 624. The system comes with 10 year waterproofing warranty from M/S Pidilite Industries/FOSROC/Asian.complete all as specified and directed by Engineer-in-charge. 10 Taking down, chipping and removing the loose, spailt, damaged cement concrete, cement mortar surfaces of RCC columns, beams, walls, chajjas etc and exposing the reinforced cement, wire brushing and cleaning the exposed steel reinforced bar, apply rust remover over the cleaned re-bar surface wash the re-bar with clean water for removing all rusts from the old re-bar surfaces, fixing new reinforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified cement and quartz sand mortar in CM 1:3 mix, 40mm average thick in two coats, with and including polymer @10% by weight of cement, including necessary steel scafolding for carrying out the work upto height of 12.0 metre (Appx) complete all as specified and as directed. Note : Reinforcement shall be measured & paid separately. 11 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 12 M&L Glazed ceramic coloured tilesin vertical surfaces of size 350 x 250x 7mm /450mm x 300mm x7mm thick set and jointed in neat cement slurryover and including 10 mm thick rendering in cement mortar 1:4for receiving the tilescomplete all as specified complete all as specified. 13 M&l fornon skid ceremic tiles 7 to 8mm thick square/ rectangular area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed for floor finishes in cement mortar 1:4complete all as specified complete all as specified. 14 Demolition of stone slabs of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc. complete removal of debris outside MD land complete all as specified and as directed. 15 Materials and labour for 15-18mm thickgranite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, urinal partitions, cooking plateform and like over and including 15 mm thick screed in cement morter (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as apecified and directed. 16 Providing edge moulding to 15-20 mm thick stone(any description) of counters vanities etc, including machine polishing to edge to give high gloss finish etc. Complete all as specified and directed. 17 M&L Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishingcomplete over and including 15mm thick screed bed in cement mortar 1:4complete all as specified and directed. 18 M&L Machine cut Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and finish complete over andincluding 10 mm thick screed bed in cement mortar 1:3all as specified. 19 M & L for Grinding& polishing of old kota stone/ marble/ baroda green floor/skirtingwith machine to mirror finish in and including making good of wall finishes as per original specifications complete all as specified and directed. 20 Demolitionof reinforced concretesuch as roofs, floors,beams, staircase,landing,chajjas,facia and similar suspended work (reinforcement cut as required to facilitate demolition) complete all as specified and directed. 21 M&L forreinforcedcementconcrete 1:2:4 type B1 (using 20 mm graded crushedstoneaggregate ) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed. 22 M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar works not exceeding 200mm thick (Horizontal or sloping) for rough finish surface of concrete. 23 M&L for mild steel TMT bars 10mm dia & over, cut to length, bent to shape reqd including cranking, bendingspecially for columns, hooking ends & binding with MS wire annealed not less than 0.9 mm dia, including necessarywelding as required at site complete all as directed and specified. 24 M&L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape reqd including cranking, bendingspecially for columns, hooking ends & binding with MS wire annealed not less than 0.9 mm dia, including necessarywelding as required at site complete all as directed and specified. 25 Demolition of brick work masonry, built in cement mortar including dismantling all quions,arches, pillars etc complete all as specified and directed. 26 M&L for brick work with sub class B bricks, straight/curved on plan exc 6M mean radius built in cement mortar 1:6 complete all as specified. 27 M&L for brick work with sub Class ‘B’ bricks straight or curved on plan exceeding 6m mean radius in half brick thick built in cement mortar 1:4 in any location, complete all as specified and as directed. 28 Taking down cement plaster on brick/stone walls of any layer up to masonry work etc including raking out joints, hackingfor key scrubbing down with water etc complete all as specified and directed. 29 Material and labour 10mm thick rendering cement plaster in Cementmortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement and providing necessary scaffolding , safety precautions and other requisite arrangements complete all as specified and directed. 30 M&L for Rough cast plaster After applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick andwhile it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravelaggregate (which is generally of size between 6 to 12 mm depending on the texture required)mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensurethat larger aggregates are thoroughly covered complete all as specified and directed, including taking down cement plaster of any layer up to masonry work and racking out joints, hacking for key scrubbing down with water etc, complete all specified and directed by Engr-in-Charge. 31 M & L for15mm thick rendering in Cement and Sand mortar 1:4 over concrete /brick surfacesfinished fair and even without using extra cement includingtaking down cement plaster from brick walls or concrete surfaces of any layer up to masonry work, raking out joints, hacking out for key, scrubbing down with water and providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed. 32 M&L for Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth without using extra cement on ceiling in cement mortar 1:3 complete all as specified and directed. 33 M& L for prepaing new plastered surfaces of wall and applying 2mm thick wall care putty andtwo coats ofoil bound distemper over a coat of alkali resistant primer at any height including necessary scaffolding etc complete all as specified and as directed. 34 M&L for preparation ofnew plastered/concrete surface of wall/chajjas/facia and applying two coats of exterior emulsion paint over one coat of primer to be applied using an airless spray machine upto any height including necessary scaffolding etc complete all as specified and directed. 35 M&L for Preparation of newly plastered surfaces of Ceiling and applying two coats of oil bound distemper white or tinted over a coat of primer complete all as specified and directed by Engineer-in-Charge. 36 M&L for preparationof old plaster/concrete surfaces andleveling / edgesing the disturbed surface with water proofing putty and applying two coat of exterior acrylic emulsion weather proof treatment upto 15 Mtr height to be applied using an airless spray machine including necessary scaffolding etc complete all as specified and directed.Note : The tint and shade be as approved by the GE. 37 M&L for complete removal of existing treatment and applying two coats of Oil bound Distemper emulsion paint, white or tinted over one coat of primer over 1.00 mm thick of wall care putty as preparatory to distemper on surfaces of wall up to any heightincluding necessary scafolding and safety arrangements complete all as specified and directed. 38 M&L for preparation of old plastered surfaces of Ceiling and applying one coat of oil bound distemper complete all as specified and directed by Engineer-in-Charge. 39 Taking down chowkhats/frames exc 1.5 Sqm but n.exc 4 Sqm including shutters (without taking off shutters from the frames complete all as specified. 40 Taking down chowkhats/frames excn.exc 1.5 Sqm including shutters (without taking off shutters from the frames) including grill etc complete all as specified. 41 Refixing of shutters in the same opening includingtaking down and easing and adjusting,belding,oiling complete.exc 1.00 sqm and not exc 2.00 sqm 42 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) Complete all as specified as per Manufacturer broucher.MAKE : RAJSHREE, SINTAX, ECOCELL OR EQUIVALENT. 43 S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. MAKE : RAJSHREE, SINTAX, ECOCELL OR EQUIVALENT. 44 S&F forPowder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions frames (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge. 45 S&F forPowder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows (two or three track sliding/openable) & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene asket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, auminium snap beading for glazing/ paneling, C.P. brass/ tainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge. 46 S&F for Powder Coated aluminium grill of approved pattern cut to required size/shape and fixed with position with aluminium bedding & frame with & including U sections, fixed to aluminium door/windows/ventilators complete all as specified and directed. 47 Material and labour foraluminium composite panel sheet of 3mm thick which consists of 3mm thick thermoplastic core of anti-toxic LDPE sandwiched between 2 skins of 0.5mm thick aluminium foils with outer surfaces finished with 30 u PVDF and inner surface finished with a thin coat of polyester paint, fixed in panel to aluminium frame including all necessary frame work or powder coated snap beading and rubber gasket complete all as specified and directed.Make :- Alstone/Alex panel/Armstrong/Euroboard 48 Supply and fixing 4.80mm thick ordinary quality tinted glass,fixed to aluminum frame work in panels not exc 0.5 Sqm in each pane, complete all as specified & directed. 49 S&F 100 mm Aluminiumhandles Extruded aluminium alloy handles, fabricated type, anodised complete all as specified & directed. 50 Supply and fix180mm size powder coated (any tint) aluminium American Handle fixed to aluminium door with suitable screws, complete all as specified and directed. 51 S & F 100 mm size but hinges medium weight stainless steelomplete all as specified & directed. 52 S&F 150 mm size Aluminium , barrel tower bolt of extruded sectioncomplete all as specified & directed. 53 Supply and Fix, Aluminium anodised, barrel tower bolts 200mm long, powder coated, of extruded section and fixed, complete all as specified and directed. 54 Supply and fixing 150mm mild steelordinary rat rail rod pattern spring including roller and roller plate, fixed complete all as specified and directed. 55 Supply and fix, Aluminium alloy, anodised, Sliding door bolts 200mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy 12mm dia, complete all as specified and directed. 56 Supply and fixing brass mortice lock vertical type 100mm size, 6 lever fixed in aluminium shutter, complete all as specified and directed. 57 S&F 5mm thick Figured glass, pin head semi type and incl glazing with oil putty/aluminium beading with rubber gasket in squares n exc 0.5 sq. m in each pane 58 S&F 4mm thick Figured glass, pin head semi type and incl glazing with oil putty/aluminium beading with rubber gasket in squares n exc 0.5 sq. m in each pane 59 S&F of Stainless Steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed Stainless Steel wire staples complete all as specified & directed. 60 S&F as in repair of Stainless Steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4 mm and fixed with Stainless Steel wire staples complete all as specified & directed. 61 M & L for old steel painted surface of any description over 10 cm in width or girth and applying one coats of synthetic enamel paintall as specified and directed. 62 M&L for preparation of old wood or wood based surfaces over 10cm width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed. 63 S&F factory made 18mm thick solid WPC (wood polymer composite) board of density 650kg/cum of one side prelaminatedwith any colour and other sidebalancing lamination, as in cupboards/kitchen/ cabinet shutter/ drawers etc fixed with screws, sovent cement, adhesive including dismantling old existing board complete all as specified & directed . Make : RAJSHRI/ ECOCELL/ SINTAX or Equivalent. 64 S&F forcontinuos piano hinges, mild steel bright finishwidth of flap 40mm,fixed as in repair complete all as specified and as directed. 65 S & F75mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plateand fixed with screwsetc complete all as specified and directed. 66 M&L for PVC Lipping 3 to 4 mm thick fixed to 18/19mm board with nails/adhesive complete all as specified and directed. 67 Demolition of RCC jallies/Trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately), complete all as specified and directed. 68 Material and labour for providing precast cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in louvres and jallies, 40mm thick (measured solid) set in cement mortar 1:6, complete all as specified and directed. 69 Excavating in post holes in Soft/loose soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and raming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified. 70 M&L for cement concrete(1:2:4) type B-2 (using 40mm graded crushed stone aggregate) asin foundation, filling and mass concrete. 71 S&F M S work as in rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other, connecting plates conforming to Fe-290 Gde E-165 complete all as specified and directed. 72 M&L for Painting on steel surcace exceeding 10cmwidth or girth with two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. 73 S&F Pre-painted galvalume aluminium zinc coating (AZ 150 ),GI based corrugated steel sheet 0.50mm thickof an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with selft tapping screws as specified complete all as specified and directed. 74 S&F in 20mm dia Stainless Steel curtain rod withfancy brackets/end brackets/ fennels andfixing stops, rollers etc complete all as specified. 75 S&F in repair of Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified. 76 S&F in repair 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. 77 S&F in repair 110mm dia PVC Rain water pipes single socketed in any length with rubber ring joints fixed to wallscomplete all as specified and directed. 78 S&F in repair 75 mm bore PVCbends of any radius complete all as specified and directed. 79 S&F in repair 110 mm bore PVCbends with accesss door of any radius complete all as specified and directed. 80 S & F PVC (SWR) junction single, (Single T) 110 mm bore equal or unequal complete all as specified and directed. 81 M&L in repair PVC SWRfloor traps 75 mm dia with gratingincluding jointing to wastepipe with run led jointed and setting/fixedin cement concrete type B-1 (1:2:4) complete all as specified and directed. 82 S&F PVC(SWR) gully traps125/110 mm dia setting and jointing with cement solvent complete all as specified and directed. 83 S&F in repair 10 litre capacity PVC valveless, syphonic action type,low level flushing cistern white complete with inlet, ball valve float and handle incl bracket all as specified and directed. 84 S & F in repairs for Vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white, with integral foot rests ( excluding flushing cistern and flush pipe) including P or S trapfixed complete all as specified and directed. 85 S&F infor Vitreous china wash down water closet pan with cover, pedestal pattern, white, fixed in repairs complete including connecting to existing cistern including P or S trapfixed complete all as specified and directed. 86 S&F in repairs for Vitreous China table top wash basin, white or ivory colour flat back, size 530mmx420mmx140mm/600x390x150mm/600x380x130mm excluding taps, waste chain and plug and porcelain stopper but including Coupling as per Model complete all as specified and directed. Make : Jaquar , Parryware , Cera 87 S&F for brasschromium plated 40mmbottle traps with wall flange for wash basins/urinal pot with inlet and outlet screwed for pipe or connections includingnecessary packing, union, cap and reducer and fixed. Make : Cera/Hindware/Parryware. 88 Cutting holes into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l exc 150 sqcm and not exc 400 sqcm complete all as specified and directed. 89 S & F GI pipe 50mm dia medium grade laid onfloor/inserted in wall incl all fittings complete all as specified and direced by EIC. 90 Cutting chases, pinning in brick wall,stone or block wall.at any height making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etcand making good, cutting exc 5 cm n ecx 15 cm girth. 91 S & F in repairs for brass chromium plated pillar cock, with extension body, screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe and fixed for 15 mm bore. Make : Jaquar , Cera, Parryware 92 S&F in repairs for Chromium plated brass angle valve for 15mm bore pipe, fixed complete all as specified and directed. Make : Cera , Parryware , Hindware 93 S&F in repairs for Chromium plated bib cock with wall flange,Screwed down, screwed for iron pipe or for brass ferrule and fixed 15mm bore complete all as spcified and directed. 94 S&Ffor Tubular towel rail of brass chromium plated, 20mm dia, D type, 60 cm long between flanges, fixed complete all as specified and directed by Engineer-in- Charge. 95 S&F in repairs for PVC connection 15mm dia and 45 cm long with 2 Nos PTMT nuts, fixed complete all as specified and directed. 96 S&Ffor Pop upcoupling of CP (half or full threaded) 32 mm to 45 mm bore fixed complete all as specified and directed. Make : Hindware/ Jaquar/ Parryware. 97 S & F 15mm bore Tubes, `medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floorsincluding Taking up or down existing pipe and necessary cutting chasing into wall etc all as specified and as directed. 98 S & F for 20mm bore Tubes, `medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floorsincluding Taking up or down existing pipe and cutting chasing into wall etc all as specified and as directed. 99 S&Fin repair for CPToilet paper holder including all fitting and fixture complete, Make : Cera/ Parryware/ Hindware. 100 S&F in repairof brass chromium plated shower rose, 125mm size with long swivel plush CP arm complete all as specified. 101 S&F in repair ofconcealed stop cock, fancy type 15mm bore, chromium plated complete. 102 S&Fin repair CP Brass mixer 15mm bore dia pipe for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. 103 Supply and fixingHealth faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect and fixed in repair ascomplete all as specified and directed. 104 Supply and fixing 1000 litres capacity rotational moulded polyethylene water storage tanks, white colour (Cylindrical vertical with threaded closed top) Triple layered hoisted and fixed in position, including PTMT tank nipple, float valve of 20 mm bore etc, including dismantling existing water tankcomplete all as specified. 105 Taking down shutter/ steel window of any description n exc 1.5sqm and refixing at same openig after welding,Resecuring ,adjusting or easing to close and opening complete all as specified. 106 M&L for 50mm thick PCC 1:3:6, Type C-1 (using 20mm graded crushed stone aggregate) as in Plinth protection, making even and smooth surface without using extra cementincl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. 107 S & Fin repair for 5.50mm thick 1200 x 750mm mirror of selected quality glass with eadge moulding, mounted on wall fixed with SS stud fixed complete all as specified and directed. 108 S & F factory made 30mm thick Glazed andskeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified inSSR Part I, Section 8, clause 8.24(a); supplied and fitted to chowkats 109 M&L for Plain cement concreteType - D2 (1:4:8) (using 40mm graded crushed stone aggregate) asin sub base complete all as specified and as directed. 110 M&L for Rubber moulded coloured (Red, Yellow & Black) precast concrete interlocking paver blocks with grey cement andpigment any shape and size, shade as approved by GE, 80mm thick conforming to IS 15658-2006M-40 grade and interstices filled with sand including 25 mm thick sand cushion complete all as specified and as directed. 111 M & L for Treating soil along the external wall below concrete or masonry apron using chemical emulsion (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on Sl. Page No. 2 of IS 6313 (Part 2) : 2013)) @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed. 112 M & L for Treating the soil under plinth protection at the rate of 5 litres of chemical emulsion (Chlorophyriphos 20 EC conforming to IS 8944 or Imidacloprid 30.50 SC conforming to IS 16131 (Refer Table 1 on Sl. Page No. 2 of IS 6313 (Part 2) : 2013)) per square metre of surface area, complete all as specified and directed. 113 Taking down carefully aluminum/copper point wiring (light ,fan, socket any type, power, bell etc.complete including fixtures & fittings (such as ceiling rose, socket, switch , Pendent, regulator, light fitting etc) and removing the materialfrom site and making good the disturbed surfaces of walls ceiling etc complete all as directed. 114 M & L for Concealed Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLSH) cable, multi-stranded, copper conductor, inuniversal colour code with & including suitable size of rigid non-metallic UPVC conduit (not less then 20mm dia med gd) and its all accessories complete concealed in wall / roofincl cutting & chases and modular flush metal boxes 0.8 mm thick( Same as Switches Make) suitable for modular fittings including modular outercover mirror/Glass finish plate with inner mountingframe of make Legrand (Arteor)/Schneider (Zencelo) /Anchor (panasonic Thea) /Goldmedal (Nexon Quorra) as per site requirementfor mounting modular switches, socketsetcincluding earth wire ofPVC insulated (FRLSH) copper conductor multistrandedof 1.5Sqmmsize in green colour including making good(i.e plastering ,one coat of putti and two coats of interior emulsionpaint with matching existing surface ) forOne light point/exhaust/ceiling fan controlled by one way switch 6 amp complete all as specified 115 All as perSrl item no 113 here-in-before but One 3 pin 6 Amps socket point controlled by one Modular switch on same board. 116 All as perSrl item no 113 here-in-before butOne 3 pin 6 Amps socket point controlled by one Modular switch on independent board. 117 All as per item No.113 here-in-before butfor 3 pin / 5 pin 16 Amps sockets outlet with 2.5 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent and 2.5Sqmm PVC insulated & unsheathed (FRLS) copper conductor earth cable complete all as specified and as directed. 118 Supply and FixingModular switch16/20 Amp single pole one way,2Module with indicator and no top gap between rocker plate and fully shrouded double rocker mechanisam type all the importent parameters like rating etc should be laser printed on every switch along with catoulage numberall as specified. Make : Legrand (Arteor)/Schneider (Zencelo) /Anchor (Panasonic Thea) /Goldmedal (Nexon ) 119 Supply and Fixingmodular socket shutter type,2-in-1,3 and5 pins 6 /16 Amps, combined 2 Module and no top gap between rocker plate and fully shrouded double rocker mechanism type all the important parameters like rating etc should be laser printed on every switch along with catalogue numbercomplete all as specified. Make : Legrand (Arteor)/Schneider (Zencelo) /Anchor (Panasonic Thea) /Goldmedal (Nexon ) 120 Supply and FixingModular ceiling rose surface bakelite Square in shape 100 mm x 100 mm, three terminals complete all as specified.Make - Goldmedal (Glassio) or equivalent in Anchor/Cera. 121 Supply and FixingModular switch 6 Amps single pole one-way, 1 Module and no top gap between rocker plate and fully shrouded double rocker mechanism type all the important parameters like rating etc should be laser printed on every switch along with catalogue numbercomplete all as specified. Make : Legrand (Arteor)/Schneider (Zencelo) /Anchor (Panasonic Thea) / Goldmedal (Nexon ) 122 Supply and Fixing Modular socket shutter type, 2-in-1, 3 pins 6 Amps ,ISI marked, combined 2 Module and no top gap between rocker plate and fully shrouded double rocker mechanisam type all the importent parameters like rating etc should be laser printed on every switch along with catoulage number complete all as specified. Make : Legrand (Arteor)/Schneider (Zencelo) /Anchor (Panasonic Thea) /Goldmedal (Nexon ) 123 Supply & FixingModular fan Regulator electronic, 8 step type 100 watt , ISI marked, 2 Module complete all as specified. Make : Legrand (Arteor)/Schneider (Zencelo) /Anchor (Panasonic Thea) /Goldmedal (Nexon ) 124 Supply and fixingpicture lights light type LED, 200-240 Volts, Muziris Picture Light - 12W, 19.6L x 7.1W x 3.7H Centimeters, lighting method Downward bulb base E27, warm/cool/natural as per site requirement , wall mountwith all accessoriescomplete connections all as specified and directed.Make :- Philips/ Jaquar/ Havells. 125 Supply and fixingdecorative ultra slim surface /Wall mounted T5/decorativeLEDbatten light complete fitting 1x 10 watt LEDsuitable for mirror light with polycarbonate channel housing & integrated electronic driver, energy efficient, warm/cool/natural as per site requirement, 140V-270 volts, including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified. 126 Supply and fixingindoor decorative ultra slim surface /Wall mounted T5 LEDbatten tube light complete fitting 1x 20 watt LED Tube fitting with aluminium channel housing & integrated electronic driver, energy efficient, 140V-270 volts, Warm/natural/cool as per site requirement type>110 Lm/Wattcomplete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified. 127 Supply and fixing of 02 feet10 Watt LED Batten with extruded aluminimum housing with high quality PC diffuser warm/cool/natural as per site requirement, complete all as specified and directed by Engr-in-Charge. 128 Supply and fixingof energy saving LED Street light of 60 Watt Capacity high pressure die cast alumininum housing with seal toughned glass cover, minimum 125 lumen/watt, cool/warm as per site requirement, operating voltage range 120 -220 Volts IP-66 surge protection including suitable GI bracket for fixing street light complete all as specifieid and directed. 129 Supply and fixing ceiling fans copper winding, complete with aluminiumblades, down rods,suitable forelectronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 215 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC )complete all as specified and directed by Engineer-in-Charge.Make : Havells/ Goldmedal/ Bajaj/ Orient. 130 Supply and fix in repair ofExhaust fan 380mm sweep, copper winding, 1900 CMH, 90 W, 4 blades with aerodynamic design, Mettallic type alongwith GIlouvers complete suitable to work on AC, single phase, 230 Volts, 1400 RPM, 50 Hzincluding connecting up with three core twisted flexible copper conductor cable of suitable size 0.75 Sqmm all as specified and directed.Make : CG/ Havells/ V Guard/ Gold Medal/ Bajaj. 131 Material and labour in replacement of Sub Main Wiring with two run single core 6.0 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed 1100 volts grade colour code cables, drawn on surfacein and including UPVC conduit of 25mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100 volts grade colour code cable for earth continuity and including making good (i.e plastering ,one coat of putti and two coats of interior emulsionpaint with matching existing surface) including taking down old, complete all as specified and directed.Note :- Two run of 6 Sqmm + One run of 6 Sqmm for earth wire + one run of UPVC conduit of 25mm dia shall be measured as one RM. 132 All as per item No 130 here-in-before but for 2 X 2.5 Sqmm + 1 X 2.5 Sqmm cable 133 Supply and fixing in replacement of Distribution board, double doorTPN 4 way,vertical typewith MCCB TPN as incomerwith 160 Amp rated bus bar IP 43 protection, cement spill protector, door earthing including MCCB TPN 100 Amp 16 KA as incomer -01 Nos complete all as specified and directed. Make : Goldmedal/ Legrand/ Havells. 134 Supply and fixingin replacementof MCB DB Single pole and neutral08 way, double door, sheet steel phospehtised powder painted withIP 43 protection 240 V neutral link, earth bar and Din rail complete all as specified and directed.Make : Goldmedal/ Legand/ Havells. 135 Supply and fixingArc Fault Detection Device (AFDD) with RCBO 32 Amp combined SPN MCB + AFDD + RCCB, offering protections for overload, short circuit, reidual current characteristices type A, over voltage protection above 270V AC +/- 5% & series, parallel arc fault, AFDD must be with dual test button for AFDD and earth leakage functions along with single diagnostic LED with blinking patterns for continious ON series arc parallel arc & over voltage protections.Make : Havells/Goldmedal/ Legand or equivalent 136 Supply &Fixingin replacementSP MCB 240 volt 5 to 32Amps,C curve, with suitable size lug thimbles integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, with efficient air chanels etc complete all as specified. Make : Legrand/ Goldmedal/ Havells. 137 Supply and fixing in replacement FRLS PVC insulated copper conductor of Size 4 Sqmm 3 core with cable thimble as required for bollards/Lt panels etc with necessary connections including UPVCconduit Heavy grade 25 mmComplete all as specified and directed. Note :- UPVC conduit along with PVC copper cable to burried in ground at a depth of 20 cm. Cost of excavation to be included in the quoted rate. 138 Supply and fixing in replacement bollard fitting 10W, neutral white, 3000 CCT, UFO Shape design, IP 65 protection including25mmUPVC conduit for passing electric cable and100mm length fastners for fixing bollard, PCC 1:2:4 (12.5 mm graded crushed stone aggregate) of size 30 Cm X 30 Cm x 45 Cm (30cm above GL & 15cm below GL) any shape or size as required including applying exteriorcementpaint over cement exposed surface, necessary formwork and excavation, removing debris outdside MoD land exc 1.5km and nexc 3km all as specified and directed.Make : Jaquar (cat part No. OBL GRY LBLDDSC010XW)/ Havells (Cat part No UFOBLS10WLED830PSYMTOPC) orequivalent in Phillips. 139 Supply and fixingin replacement of LED flood light 100 watt 230 V AC with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make :- Philips/ Jaquar/ Havells. 140 Supply and fixingin replacementof LED decorative post top light fitting 40 watt,Neutral white ,3000 CCTdesigned spun aluminium and high grade aluminium heat sink for efficient thermal management, sturdiness and excellent corrosion resistance with MS base, IP 66 protection having glare free and better uniformity light distribution complete all as specified and directed. Make :- Philips/ Jaquar/ Havells. 141 Supply and Fixingin replacement of Modular switch 20 Amp single pole one way, 2 Module with indicator and water heater marking by using new concealed sunken pressed steel terminal boxes 0.8 mm thick (Same as per Switch Make) with inner mounting frame and outer Mirror/glass finish cover plate 2 Module of suitable size for mounting of modular switches, sockets, fan regulators etc fastened with chromium plated screws including making good (i.e plastering, one coat of putti and two coats of interior emulsionpaint with matching existing surface) complete all as specified and directed. Make - Goldmedal (Nixon Quorra)/ Legrand (Arteor)/ Anchor (Panasonic Thea)/ Schneider (Zencelo). 142 Supply and fixingin replacementof MCB protected modular socket with Modular MCB 16 Ampsbuilt in Modular MCB + Modular Socket 16 Amps+PRCD Top 3 Pin, 16 Amps 30 mAwith concealed metal sheetsteel enclosure 0.8 mm thick (Same as per Socket Make) with inner mountingframe and outer Mirror/glass finish modular cover 3 Modulefor mounting including making good (i.e plastering, one coat of putti and two coats of interior emulsionpaint with matching existing surface) complete all as specified and directed. Make - Goldmedal (Nixon Quorra)/ Legrand (Arteor)/ Anchor (Panasonic Thea)/ Schneider (Zencelo). 143 Supply and fixingwater storage heater vertical (geyser) with inner Tank Material :TitaniumGlass Lined coated Tank - 2X Corrosion Resistance, Outer Body Material : ABS, Type : Storage, Capacity : 25 Litres, AC 220-240 Volts, Wattage : 2000 Watts, with preset thermal cutout, Pressure : 8 Bars, BEE Rating : 5 Star, Multifunction 4 in 1 safety valve, glass coated heating element, adjustable temperature control knob, Magnesium anode rod, install on wall by anchor fastnerscomplete with three core twisted flexible copper conductor cable of suitable size upto 2 metre all as specified and directed. Make - Gold Medal (Hydro)/ Havells (Magnetron)/ Jaguar(Elena).
Contract Date: Feb 11, 2026 Contract Value : 37.55 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
33.
Agriculture #9519259 Technical Bid
Tender For Construction Of Divisional Office Building Vellore At Fsd Sevur Tamil Nadu Region (Recall).; 1 Civil ( S.No.1-96) Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead upto 50m and for all lift as directed by Engineer-in-Charge. a) All kind of soil. 3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. 4 Supplying and filling in plinth withsand under floors, including watering, ramming,consolidating and dressing complete. 5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: a) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources) 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 7 Treatment of soil using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With chlorpyriphos/lindane E.c. 20% with 1% concentration 8 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work;usingcoarse aggregate and fine aggregate derived from natural sources,portland pozzolana / ordinary portland /portland Slagcement,admixtures in recommended proportions as per iS: 9103 to accelerate /retard setting of concrete, to improve durability andworkabilitywithout impairing strength; including pumping of concrete to site of laying, curing,carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge;for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately.in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 1)concrete of m30 grade withminimum cementcontent of 350 kg /cuma) All works upto plinth level 9 b)All works above plinth level upto floor V level 10 Centering and shuttering including strutting, propping etc. and removal of form for all heights.a) Foundations, footings, bases of columns. etc. for mass concrete 11 b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 12 c) Suspended floors, roofs, landings, balconies and access platform 13 d) Columns, Pillars, Piers, Abutments, Posts and Struts 14 Stairs, (excluding landings) except spiral-staircases 15 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.a) Thermo-Mechanically Treated bars of grade Fe-500D or more 16 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a)Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. a)Cement mortar 1:4 (1 cement :4 coarse sand) 19 12 mm cement plaster a) 1:6(1 cement: 6 fine sand) 20 15 mm cement plaster on rough side of single or half brick wall of mix: a) 1:4 (1 cement: 4 fine sand) 21 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) 22 18 mm thick moulded cement mortar band in two coats under layer 12 mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) top layer 6 mm thick with cement mortar 1:4 (1 cement : 4 fine sand). 23 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shades, laid on 20mm thick cement mortar 1:4 (1 cement:4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of the tile 600x600 mm 24 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved brand & manufacturer, in all colours & shade, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement & matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only, laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size b) Size of Tile 600x600 mm 25 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 26 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. a)Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 27 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 28 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.a) On steel work 29 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 30 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/ wooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/ grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Finishing with Deluxe Multi surface paint system for interiors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 33 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 34 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 35 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 36 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 37 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5” or 4.2” or 6”) or step-down (2” or 3” or 6” ) as specified 38 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced withgalvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware,SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleevefor fixing frame to finished wall as perIS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof Silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paidseparately.Note:- Structural design proof checked from a Government Engineering Institute,to be provided by the manufacturer for : (i) Siteswith basic wind speed > 45 m/sec as per IS 875 – Part 3(ii)Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre). 39 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread offlame of Class Acategorywith property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance indimensions i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. a)Frame size 50 x 125 mm 40 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread offlame of Class Acategory with property of being termite/borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) a)35 mm thick 41 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 42 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matchedteak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 43 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only 44 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters. 45 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) 46 Providng & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 5.5 mm thick glass panes 47 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure ation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge.The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for cupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and formation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for ualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a ssure range 50 kpa to 240 kpa (35psi) upto 2000 mlNote:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified boratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 0pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. 48 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. 49 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 50 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 51 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). 52 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge.a)200 mm 53 Providing and fixing Godrej Stainless Steel Glass to Glass Round Lock 7780 complete as per direction of Engineer-incharge. 54 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm 56 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and pair of lever handles of approved quality with necessary screws etc. complete. 57 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less thangrade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 58 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizont al level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mmthick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thicksheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 59 Full ht. 75 mm. thk Solid Partitions/Semi Glazed Partitions with both side 12mm commercial plywood and 1mm thick Laminate & Providing Aluminium frame of size 50x50x1.8 mm thk (finished) comprising of horizontals and verticals at, 600 mm c/c ,vertically and horizontally fixed firmly to walls / floors / RCC roof etc. Alternate vertical members to go upto RCC ceiling and firmly fixed. Providing 8 mm thk. ISI grade plywood of approved make , finished / fixed with 1 mm thick laminate of approved make & shade fixed with adhesive , fixed on both sides of the partition framework. The laminate to be fixed with adhesive on both sides of the partition upto False ceiling level. 60 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of followingoperations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treatingsimilarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved byEngineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer ofplaster and finally finishing the surface with trowel with neat cement slurry and making patternof 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 61 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 62 Providing & applying patterened texture work on extrenal wall with birla or equivalent brand putty on plastered surface as approved by Engineer-in-Charge, 63 Providing and fixing of FRP Security Cabin in Size of 2.5x2.5x2.5m with M.S frame structure and covered by FRP Pannel and FRP Pyramid shape Plane Roof. FRP Door thick - 20mm (6x2) With, ALdrop, Handel, & 3 Nos. SS Ingies.Inside & Outside writing Counter, Size- L-4x W-11Electrical Point- Inside &Outside Bulb Point, 1plug, 3 Switch,Cloth Hanger- 01Nos as per Engineer in Charge. 64 PLUMBING Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : A) W.C. pan with ISI marked white solid plastic seat and lid 65 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board, 510x1040 mm bowl depth 225 mm 66 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : (Size 600x450x200 mm) 67 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. 68 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 69 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 70 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 71 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing:Oval shape 450x350mm (outer dimensions) 72 Providing and fixing toilet paper holder : C.P. brass 73 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Sand cast iron S&S as per IS-1729 74 Providing and fixing soil,waste and vent pipes: Centrifugally cast (spun) iron socketed pipe as per IS: 3989. 75mm dia 75 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm dia Hubles centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 76 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.75 mm dia Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905. 77 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 78 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal Inner dia Pipes 79 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc.25 mm nominal outer dia Pipes 80 Providing and fixing Chlorinated Polyvinyl (CPVC) pipes, having thermal stability for hot &cold water supply including all CPVC plain & brass threaded fittingsi/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes &fittings with one steps CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes 81 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 82 Providing and placing on terrace (at all floor levels) polythylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 83 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size ) , including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 84 EXTERNAL INFRASTRUCTUREConstruction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in Charge. a)With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 85 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 86 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). Size of 100x0.375x0.20 87 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 88 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :Screened through sieve of I.S. designation 16 mm 89 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 90 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 91 Fine dressing of the ground 92 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 93 Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v 94 Providing and stacking of Plumeria acutifolia of height 120-135 cm. with 2-3 branches in HDPE bag of size 30 cm as per direction of the officer-in-charge. 95 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge 96 Washingtonia filifea palm stem ht. 90-105 cm with 6-7 healthy leaves lush green leaves well developed in big size HDPE Bag 97 Electrical ( S.No.97-211) Supplying of PVC/XLPE armoured cable with aluminium conductor 1.1KV Gradeconfirming to IS 7098 (part I)1988 with upto date amendments of the following size at the site of work3 1/2 X 120 Sq.mm 98 3 1/2 X 70 Sq.mm 99 4 X 25 Sq.mm 100 4 X 10 Sq.mm 101 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 102 150 mm width X 50 mm depth X 1.6 mm thickness 103 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 104 150 mm width X 50 mm depth X 1.6 mm thickness 105 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness 106 150 mm width X 50 mm depth X 1.6 mm thickness 107 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 108 Supplying and fixing of light class G.I. pipe of 100 mm dia.(nominal) 3 metres length along the pole for protection of under ground cable as required. 109 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench as required but excluding sand cushioning and protective coveringUpto 35 sq. mm 110 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185sq. mm 111 Up to 35 Sq mm 112 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 113 Upto 35 sq. mm (clamped with 1mm thick saddle) 114 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as requiredAbove 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) 115 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 116 Upto 35 sq. mm (clamped with 1mm thick saddle) 117 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 120 sq. mm (45mm) 118 3½ X 70 sq. mm (38mm) 119 4 X 25 sq. mm (28mm) 120 4 X 10sq. mm (25mm) 121 Supplying and fixing hot press molded SMC box of size 140x140x95 mm outside with suitable clamps to the wall/pole/truss/GI Pipe, including providing and fixing of 3 way connectors of suitable rating ,providing and fixing 6A C curve MCB, terminating the incoming and out going cables /wires (but with out end termination glands) making connections etc. as required 122 Supplying and fixing of follwing way sueface / recess mounting vertical type , 415 V , TPN MCB distribution board of sheet steel, dust protected , duly painted , inclusive of 200 A tinned copper bus bar , common neutral link , earth bar , for mounting MCBs (but without MCBs and incomer ) as required4 way ( 4 + 12 ) , Double door 123 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator)8 way (4 + 24), Double door 124 6 way (4 + 18), Double door 125 4 way (4 + 12 ), Double door 126 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 127 Triple pole 128 Supplying and fixing following rating, four pole, 415V isolator in the existing MCB DB complete with connection , testing and commissioning etc. as required 40A 129 63 A 130 Providing and fixing following rating and breaking capacity and pole MCCb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel making connections , etc as required100 A, 30 KA, FP MCCB 131 Supplying & fixing suitable size GI box with modular plate and cover in fornt on surface or in recess including providing and fixing 25A modular socketoutlet and 25A modular SP MCB , Ccurve includingconnections , painting etc , as required . 132 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 133 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 134 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 135 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 136 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 137 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 138 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 3pin 5/6 A modular socket outlet and 5/6 modular swith connections etc.as required . 139 Supply and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, inculing providing and fixing 6pin 5/6 A & 15/16 modular socket outlet and 5/6 modular swith connections etc.as required . 140 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 141 3 pin 5/6 A socket outlet 142 15/16 A switch 143 6 pin 15/16 A socket outlet 144 Telephone socket outlet 145 RJ45 computer socket cat 6 146 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125mm X 125mm) 147 6 Module (200mm X 75mm) 148 1 or 2 Module (75mm X 75mm) 149 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 150 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.1 run of cable 151 2 run of cable 152 3 run of cable 153 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.1 Pair 154 2 Pair 155 Earthing with G.I. earth plate 600 mm X 600 mm X 6mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 156 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 157 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess For connections etc. as required. 158 Providing and fixing 6 SWG dia G.I. wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 159 Earthing with copper earth plate 600 mm X 600 mm X 3mm thick including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre longetc . With charcoal coke and salt as equired 160 Providing and fixing 4.00 mm dia copper wire on surface or in recess For loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 161 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I tube, having single prong at top, with 85 mm dia 6 mm thick . base plate including holes etc. complete as required. 162 Jointing copper / G.I tape (with another copper / G.I tape, base of the final or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required 163 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required (For horizontal run) 164 Providing and fixing G.I tape 20mm X 3mm thick on parapet or surface of wall For lightning conductor complete as required(For vertical run) 165 Providing and fixing testing joint , made of 20 mm X 3 mm thick G.I. strip , 125mm long , with 4 Each. of G.I bolts, nuts, chuck nuts and spring washers etc. complete as required. 166 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required . 167 Supplying, installation, Testing and commissioning of 90W LED Street light fittingmade up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 in the existing streetlight pole with suitable clamps and nut bolts including giving connection etc., at site of work as required 168 Supplying, installation, Testing and commissioning of 36 watt 2X2 LED flat panel recess mounting luminaire with high brightness LED as light source, suitable for Armstrong/Grid ceiling and fixing on ceiling with suitable hanging chains, clamps and nut bolts including giving connection testing etc., at site of work as required 169 Supplying, installation, Testing and commissioning of 12 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 170 Supplying, installation, Testing and commissioning of 18 watt Round surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 171 Supplying, installation, testing andcommissioningof 20W LED T8 tubelight with Al body, PC diffuser and inbuilt driver along with Highly robust box type luminare suitable for single T8 LED tube and fixing on wall/ceiling by using necessary clamps etc., at the site of work as required 172 Supplying, installation, testing and commissioning of 20W LED tube alongwith Industrial Batten of Environmental friendly, long life, corrosion resistant, impact proof, surface mounting IP66 luminaire with PC housing & opal finish cover suitable for single T8 LED tubelight and fixing on wall/truss by using necessary clamps etc. as required 173 Supply and fixing of7W LED surface mounted LED mirror light luminarie complete and fixing on wall by using necessary clamps etc., at the site of work as required 174 Supplying, installation, Testing and commissioning of 24 watt square surface mounted LED panel light fitting made of pressure die-cast aluminium luminaire and high translucent frosted plastic diffuser and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 175 Supplying, installation, Testing and commissioning of 40 watt LED 5700K Post top lantern IP65 with high power LEDs as light source and fixing on pole with suitable clamps and nut bolts including giving connection testing etc., at site of work as required 176 Supply and fixing of 10W pressure die cast aluminium housing Bulk Head LED fitting with IP66 protected withPVC unsheathed copper leads from terminals to the fitting and fixing on ceiling with suitable clamps and nut bolts including giving connection etc., at site of work as required. 177 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR Item for BEE 5 star rated Ceiling fan with Brush Less Direct Current (BLDC) motor 178 Supplying and fixing of single phase, 230V,50Hz, 1800 rpm, 200mm dia sweep, 5 blade Exhaust fan with bird screen for protection against birds & Foreign material and fixing on the wall surface including giving connections etc. at site of work as required 179 Supply of 6 mtr high hot dipped galvanised octagonal poles with 130 mm bottom dia and 70 mm top dia made up of 3mm thick HT sheet along with base plate of size 200x200x16 mm thick along with 4 nos of M20x600 mm high J type 8 EN grade foundation bolts along with template to fix the pole to the foundation and supply of 1 mtr long hot dipped galvanised single arm bracket made up of 40NB dia GI pipe suitable to mount on pole having top 70 mm dia for mounting the street light fixture 180 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregrate 40mm nominal size) foundation including excavation and refliing etc. as required 181 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.1.2 TR 182 2.0 TR 183 2.8 TR 184 Supply, Installation, Testing and Commissioning of 1.5 Ton/4500 Kcal/hr, 5 Star Rating Inverter technology High wall split type Air Conditioner with minimum of 3 metre length of copper Refrigerant piping with insulation and electrical cable complete with indoor unit (IDU), Outdoor unit (ODU) suitable For 230V +10% of 50 Hz, single phase AC supply and Fixing on the wall surface including giving connections etc. at site of work as required 185 Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 186 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required19 mm dia (OD) (Hard drawn) with tube thickness 1.2mm with 19mm thick insulation 187 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation 188 Supply and fixing of FP sheet enclosure on surface/recess along with 63A FP C curve MCB complete with connections, testing and commissioning etc. as required 189 Design, Fabrication,Supplying, Installation, Testing and commissioning of Dust and vermin proof Cubicle type LT panel boardsuitable For 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity For Phases & neutral (min. of 250A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge. 190 Design, Fabrication, Supplying, Installation, Testing and commissioning of 315A near by control box with 4 pole 315 A MCCB switch with front handleDust and vermin proof Cubicle type LT panel boardsuitable for 3 Phase,415V,50 Hz 4 Wire AC Supply System fabricated in compartmentalized System made out of 14 SWG CRCA Sheet Steel and painted with powder coating in approved shade and comprising of the following:Complete with aluminium busbars ofadequate capacity for Phases & neutral (min. of 250 A), Suitable M.S Angle Base Frame, cable alley, interconnections control wiring, including incoming and outgoing cables connections etc as required at site of work and as directed by the Engineer in charge 191 Design, Fabrication, Supply, installation, testing and commissioning of 30KVAR Automatic power factor correction panel (APFC) with 6steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment For each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 6 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars. capacStart, Stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus For the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, MV panel sensing CT interconnecting wiring etc., complete 192 Supply, Erection, testing and commisioning of 82.5KVA/66 KW Diesel Generating Set (as per the latest CPCB IV+ norms) comprising of Water Cooled, 4 cylinder Diesel engine developing minimum of 102 BHP with electric start compression ignition 4 stroke designed to run continuously at at 1500 RPM. Coupled to Alternator rated at 1500 rpm, 415 Volts, 0.8 power factor, 50 Hz, three phase supply, self-excited and self-regulated, brushless, floor mounted with ball or bearings on end shields and fuel Tank of minimum 150 Ltrs capacity with Standard Control Panel with Breaker, Batteries and Acoustic Enclosure including Transportation, loading-Unloading, UG cable laying from generator to panel, earth strips connections etc., at the site of work as required (Model should have minimum 2 year warranty) 193 Supply, Installation, Testing and Commissioning of 15kVA DOUBLE CONVERSION 3 phase input,3 phase output True Sinewave ONLINE UPS with 0.99 power factor including stand along with supply and erection of 12V/26AH SMF Batteries (30mis back up) of 30 nos.including providing necessary connections etc. complete as required 194 Supplying, fixing and testing of CO2 fire extinguisher of 4.5 kg capacity with hose and horn confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 195 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 10 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 196 Supplying, fixing and testing of ABC Fire Extinguishers Filled with Mono Ammonium Phosphate Dry Powder of 6 kg capacity suitable For all Types of Fires confirming to relevant ISI specification including fixing on suitable wall mount bracket/ clamp/ hook and nuts,bolts etc., at the site of work as required. 197 Supplying and fixing of MS angle fire bucket stand with 03 Each fire buckets of 10 litre capacity, at the site of work as required. 198 Supplying, installation, testing and commissioning ofsmoke detection system with minimum of 36 Each conventional type photo-electric smoke detectors, 2x1.5 sq.mm fire resistant armoured cable(red colour), 6 Each Manual Call points, 6 Each Hooters complete with 2 zone fire alarm panel etc at site of work as required 199 Supply, Installation, Testing and commissioning of 16 channel 4 SATA NVR, with 4T Hard Disk Drive 1 Each, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface For HDD connection, Support upto 10TB capacity For each HDD, Smart search For efficient playback. and smart playback to improve the playback efficiency, Supports VCA search For fire/ship/temperature /temperature difference detection triggered video files, POS inFormation overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect For easy network management, 2 Gigabit Ethernet network interfaces 200 Supply ,Testing and Commissioning of 4MP Infra Red Dom Camera and fixing the same on wall/ceiling including providing necessary connections etc. complete as required 201 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse 202 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3Each m) USB -3Each n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37) 203 Supply, laying and termination of high quality Un- Armoured Optical Fiber (48 Fibers) along with the all accessories connectors, switches etc complete as required 204 Supply, fixing and termination of high quality rack mounted type patch panel with one number of 24 port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer 205 Supply, fixing and termination of high quality floor mounted type 24U floor mountable powder coated Rack with 3x5A Power Manager, 1 position fan, min 1 nos of shelf, Front Glass double door with Lock & key with suitable network port switch, fixing frames, links and interconnections, necessary accessories etc., all complete as per specifications, drawings and / or as directed by the Engineer in charge 206 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with followingcomponents complete as required:-a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modulesused in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust thevoltage and frequency level to suit the Grid Voltage Frequency.c) Data Monitoring System complete with accessories.d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugsand other accessories etc. as required.e) Lightning and surge voltage protection.f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 207 Supply, Erection, Testing and Commissioning of new 160 kVA, 11kV/433V, 3-Phase, 50 Hz, ONAN Cooled, Copper wound Transformer with Energy Efficient level-I, Dyn11 vector group, first fill of oil, Bushing on HT side & Cable box on LT side, off circuit tappings of +5% to -10% in steps of 2.5% with standard fittings confirming to IS 1180, including transportation of the machine from OEM factory to site, mechanized mounting of transformer in the DT structure, providing necessary cable end terminations (LV side), connection of 4 SWG copper down conductor (HV side), body and neutral earth connections, insulation resistance testing and certification of the same etc. as required 208 Providing new service connection to the Divisional Office building by preparation of drawings, coordinating with EB, deposit amount/ statutory charges to be paid to EB for supply and fixing of poles/DT structures, overhead ACSR conductors, associated accessories, including any additional works as per the instruction of EB/FCI engineer-incharge etc. as required. (Deposit Amount/Statutory Fees will be paid by FCI as per actual only) 209 Supplying and drawing of Multicore Round PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conForming to IS: 694in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm 210 Supply,erection and testing & commisioning of 2HP submersible pumpset in theOpen borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge. 211 Supply of 2m x 1m x 3mm thick corrugated rubber mat as required conforming to relevant ISI specification suitable for electrical application
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 11
34.
Public Administrative Department #9500656 Price Bid
Tender For Renovation And Upgradation Work Of 3Rd And 6Th Floor Of Authority Office Building New Building - CIVIL-TOILET SANITARY FITTING WORK 2 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: of area 3 sqm and below. 3 Dismantling Aluminium / Gypsum partitions, doors, Windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge. 4 Demolishing Brick work Manually / by mechanical means including stacking of Serviceable material and Disposal of Unserviceable material within 50 meters lead as per direction of Engineer-in-charge.in Cement mortar. 5 Demolishing R.C.C. work Manually / by mechanical means including stacking of Steel bars and Disposal of Unserviceable material within 50 meters lead as per direction of Engineer-in-charge. 6 Extra for Cutting Reinforcement bars Manually by mechanical means R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work)as per direction of Engineer-in-charge. 7 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. For thickness of tiles 10 mm to 25 mm. 8 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 9 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. 10 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 11 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) 12 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) 13 12 mm thick cement plaster of mix: 1:4 (1 cement: 4 coarse sand) 14 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes. 15 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes. 16 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes. 17 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm 18 Providing & Placing of Looking Mirror pasted on wall with the help of silicon having edges beveled, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge. Customized 19 Providing & Fixing ofConcealed Stop Cock With Trims as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 20 Providing & Fixing ofFloor Drainer as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent 21 Providing & Fixing ofWall hung Closet with Soft Close Seat Cover Fixed with Jumbo Bolts as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 22 Providing and fixing Urinal With Sensor Make-Kerovit,as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. 23 Providing and fixing Urinal Partition Make-Kerovit,as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. 24 Providing & Fixing of Concealed Cistern With Push Plate as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 25 Providing and fixing of Half/Full Pedestal Basin as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 26 Providing & fixing of Pillar Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Jaquar/American Standard/Kerovit Eqivalent 27 Providing and fixing Sink Mixer as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 28 Providing and fixing 2 Way Bib Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent 29 Providing & fixing Health Faucet as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent 30 Providing and fixing of Angle Cock as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 31 Providing and fixing of Bottle Trap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 32 Providing and fixing of Toilet Paper Holder as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 33 Providing and fixing of Towel Ring as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 34 Providing and fixing of Soap Dispenser as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 35 Providing and fixing of Waste Coupling as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent 36 Providing and fixing of Long Braided Hos Pipe as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. 37 Providing and fixing of 110mm dia pipe 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 38 Providing and fixing of 110mm dia Elbow 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 39 Providing and fixing of 110mm dia 45 Degree Elbow, 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 40 Providing and fixing of 110mm dia Socket, 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 41 Providing and fixing of 110mm dia Tee, 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 42 Providing and fixing of 110x110mm dia Nahani Trap, 6kg pressure of Supreme make or equivalent, including supply of all materials, labour and T&P etc. 43 CIVIL-INTERIOR WORK ESTIMATE 44 Providing & Fixing of at all height false ceiling including providing and fixing of frame made of special section power pressed from m.s. sheet and galvonised in accordance with zinc coatingof grade 350 as per IS 277and consisting of angle cleat 25x1.6mm with flanges of 27mm and 37mmat 1200mm c/c one flangedfix to the ceiling with dash fastener 12.5mm dia and and 40mm long with 6mm dia boltto the angle hangers of 25x25x0.55 mm of required lengthened other end of angle hanger being fixed with nut and bolts to GI channel 45x15x0.90mm running at the rate of 1200 mm c/c to with the ceiling section 0.5mm thick button wedges of 80mm with tappered flenges of 26 mm each having clips of 10.5mm.at 450mmc/ cshall be fixed in direction perpendicular to GI channels with connecting clipsmade out of 2.64MM diax230mm longGI wire at every junction including fixing the gypsumboard with ceiling section and perimetre channels 0.50 mm thick 27mm high having flenges of 20mm and 30mm long ,perimeter of ceiling fixed to wall /partitionwith help of rawl plugs at 450mm c/c with 25 mm long drive all screws @230mm interval including jointing and fixingto a flush finish of tapperedend sq edge of board with recommended filler jointing and tapper finisher and two coat of primer suitable for board as per manufacturers specification and also including the cost of making of openning for light fittings grills diffusers cutouts made with frame of perimeter channelssuitably fixed all complete as per drawing and specification and direction of engineer incharge but excluding the cost of painting. 12.50mm thick tapered edge gypsum board. 45 Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with Dune (Bevelled Tegular) Edge Tiles With Armstrong 15mm Exposed GRID.The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 63%.The tile shall be laid on Armstrong Suprafine 32 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 32mm and a load carrying capacity of 8.8 Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre.The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module.Cut cross tees longer than 600mm require independent support.600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres. ARMSTRONG SUSPENSION SYSTEM - Armstrong make Anchor Fastener, Hanger Wire 2.5mm dia, Hook Clip with J Wire assembly. Approved Makes - Armstrong, Shera, Nitco. 46 Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing C wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 47 Providing and laying & Repairing Existiting vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 48 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 49 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm 50 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 51 Providing & Making & Fixing of Wooden Wall Panelling made with Aluminium Section of 2x1 @ 2CC frame work cladded with 12MM Ply & Finished with 1MM Laminateon One Side complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Architect/Engineer -in-Charge. 52 Providing & Making & Fixing of Wooden Wall Partition made with Aluminium Section of 2x1 @ 2CC frame work cladded with 9MM Ply & Finished with 1MM Laminateon Both Side complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Architect/Engineer -in-Charge. 53 Providing & Making & Fixing of Wooden Wall Panelling made with Aluminium Section of 2x1 @ 2CC frame work cladded with 4MM Veneer complete with Water Base PU Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 54 Providing & Making & Fixing of Wooden Wall Panelling made with Aluminium Section of 2x1 @ 2CC frame work cladded with Coloured Lacquered Glass as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 55 Providing & Fixing of 12MM Toughened Glass Door with all hardwareas per design with edge polish m/c top & bottom pivot and bottom lockwith handle all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 56 Providing & Fixing 12MM Toughned Glass Partition Modi float glass fixed edge to edge as per design and drawing and polished where required along with neccesary hardware all complete as per drawing, specification and direction of engineer incharge. 57 Providing & fixing of 32MM Flush Door complete with all Fittings Like Hinges, Mortis lock, Door closer, Tower Bolt etc all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 58 Providing & Fixing of Plotter Cutted Designer Film of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 59 Providing & Fixing of Plotter Cutted Designer Coloured Vinyl of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 60 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 5 mm shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. 61 Providing & Fixing of Roller Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. 62 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 63 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 64 Providing & Making & Fixing of Storage Cabinet made of 19MM Board, having shelves & shutters & teak wood beading & finished surface of 1MM Laminate including all hardware like tower bolts, hinges, lock & handle as per approved drawing & direction of Engineer incharge. 65 ELECTRICAL WORK ESTIMATE 66 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A 67 Supply and fixing of Power point and Supply and fixing of power plug with 10 Amp./250 volt flush type modular switch and 5 pin 10A /250 volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. 68 Supply and fixing of wire, Power point and Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 nA/250 volt flush typ[e universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. 69 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 70 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 71 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire 72 Supplying & Drawing co-axial TV cable RG-6 grade, 0.7 mm. solidcopper conductor, PE insulated] shielded with fine finned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required. For T.V. Socket outlet 73 Providing Drawing Connecting And Testing Of Enhanced Categoey 4 Pair Lan Local Area Network Cable 24 AWG Conductor Performance Specifide 5E U L and CUL Listed In Existing PVC Conduit .(CAT-6 Network Cable) 74 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 20MM 75 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 25MM 76 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 32MM 77 Supplying & fixing of TV Antenna socket on Modular Plate & G.I Box including connections 78 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 1 or 2 Module 79 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 3 Module 80 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 4 Module 81 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 6 Module 82 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 8 Module 83 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 12 Module 84 Blank plate for modular plate type switch boards wherever required. 85 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 86 S&F of 125 Amp 4 pole MCCB (25 KA) Thermal Magnetic release 87 S & F surface/Flush mounting 12ways V TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. CAT-A 88 Supply and fixing of recess mounting round15 TO 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AAA 89 Supply and fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAA 90 Supply and fixing of 150mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent 91 Supply and fixing of 400mm Wall Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent 92 Supply & Fixing of LED Profile Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 93 Supply & Fixing of LED Profile Light Driver all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 94 Supply and Fixing of Deep Recess Mounting round 10 Watt COB LED Spot Light having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent 95 Supply & Fixing of 150MM Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton Grand-6 96 Supply & Fixing of 150MM Gravity Grill For Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton Gravity Grill-6 97 Supply & Fixing of 150MM Air Valve For Inline Mixflow Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Rexton CAV-6 98 Supply & Fixing of 110MM Ceiling Mount Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton 99 Providing & Fixing of Call Bell Chimes all complete as per drawing and specification and direction of engineer incharge. Make-L&T 100 Providing & Fixing of 1200MM Designer Hanging LED Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledlum 101 Providing & Fixing of Modular plate type white RJ 45 CAT 6 Data/Talephone outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required with RJ-45 Data outlet 102 FURNITURE WORK 103 Providing & Making & Fixing of Conference Table Made of 19MM Board, Topand Vertical drop 19MM ply board. All the surface to be cladded with 1.5 mm Mica & Having S.S Frame Square Section of 302 Grade. All the Edges to be lipped with 4MM Veneer which shall be Water Based PU Polished, all complete as per design approved by E/I & Architect Incharge. Customized 104 Providing & Fixing, Table of Size - COLLABORATE 1800 MM WITH SIDE STORAGE AND WITHOUT HEIGHT ADJUSTABLE EXTENSIONMAIN TABLE - 1800W X 900D X 750HTCOMPOSITE SIDE STORAGE - 1050W X 450D X 750HTThe Collaborate 1800 mm executive workstation is a thoughtfully designed compact desk setup ideal for modern office environments. The main desk measures 1800W x 900D x 750H mm and is crafted with a 25mm thick pre-laminated particle board tabletop, finished with 2mm PVC edge lipping to ensure long-term durability and impact resistance. The tabletop offers a clean and modern appearance suitable for executive and managerial spaces.The workstation is structurally supported by mild steel (MS) powder-coated loop legs, featuring a distinctive 55x55mm diamond profile. These are paired with die-cast metal connectors and reinforced with MS cross beams, ensuring superior strength and stability while adding a refined industrial aesthetic. A front modesty panel made of 18mm thick pre-laminated particle board with 2mm PVC edge lipping, and a standard height of 450mm, ensures privacy without compromising open design.For integrated electrical management, the desk features a 350mm wide metal flip-up cover with a soft closure mechanism, offering concealed access to switchboards and power/data outlets. The MS cable dump tray beneath the tabletop is designed to house switches and sockets efficiently. Additionally, a vertebra-type vertical wire manager (cable spine) is provided for seamless and organized cable routing from floor level to the desk, enhancing safety and aesthetic appeal. Accompanying the main desk is a composite side storage unit measuring 1050W x 450D x 750H mm, constructed from 18mm thick pre-laminated particle board for a consistent and coordinated look. This side unit offers a combination of closed storage and drawers for functional workspace organization. The configuration includes three drawers (2 box drawers + 1 file drawer) along with shuttered compartments, allowing versatile storage for office supplies, documents, and personal belongings. All shutters are equipped with auto-closing hinges to ensure smooth, silent operation. The drawers and shutters feature integrated finger groove handles for a clean, handle-less appearance, and the entire unit is fitted with a central locking system to ensure safety and security of stored materials. Adjustable shelves provide flexibility in internal space utilization, while levellers ensure stable placement even on uneven flooring. All essential hardware components are included, supporting ease of assembly and reliable daily usage.. Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 105 Providing & Fixing, Linear Workstation of Size:- NEO WORKSTATION -1200X600 Specifications - Partition system WITH PARTITION ON MAIN SPINE , INTERMEDIATE AND ENDS The NEO Workstation is a modern, modular workspace solution designed for efficient and ergonomic usage in collaborative office environments. Each workstation measures 1200W x 600D mm and is integrated with a structured partition system that provides defined workspaces with optimal privacy and utility. The system features partitions on the main spine, intermediate panels, and end panels, creating a consistent, enclosed workspace layout. The partition system stands at a total height of 1200mm and is built using a frame structure with top and side aluminium trims, offering a sleek, modern appearance while maintaining structural integrity. All vertical junctions and corners are finished with high-quality die-cast aluminium caps, ensuring clean detailing and long-term durability. The workstation surface consists of a 25mm thick pre-laminated particle board tabletop, finished on all exposed edges with 2mm PVC edge lipping, enhancing durability and resistance to everyday wear. The tabletop offers ample personal workspace, making it ideal for focused individual tasks within a shared environment. Support for the tabletop is provided through 18mm thick pre-laminated gable ends, offering solid lateral stability while maintaining a minimalist design. The gable ends match the tabletop in finish and style, ensuring a unified look across the workstation cluster. For efficient cable management, the workstation is equipped with a 65mm diameter grommet cap on the tabletop for cable entry. Beneath the surface, a metal raceway tile is provided for mounting electrical switches and sockets, ensuring clean and accessible power connectivity. A metal skirting tile is also included below table level, specifically designed for data cable routing along the main spine, ensuring complete segregation and safety of power and data lines. Tile finishes are thoughtfully planned to enhance both utility and aesthetics. Above table level, the partitions feature fabric tiles, offering tackable surfaces for personal pin-up needs. Each workstation includes one glass marker tile for easy jotting of notes and tasks, and one magnetic tile for pinning magnetic objects or accessories. Below the tabletop, pre-laminated tiles are used for durability and easy cleaning, while metal skirting tiles on the main spine facing the user provide a robust, high-utility finish with integrated cable routing., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 106 Providing & Fixing, Linear Workstation of Size:- NEO WORKSTATION -1350X600 Specifications - Partition system WITH PARTITION ON MAIN SPINE , INTERMEDIATE AND ENDS The NEO Workstation is a modern, modular workspace solution designed for efficient and ergonomic usage in collaborative office environments. Each workstation measures 1350W x 600D mm and is integrated with a structured partition system that provides defined workspaces with optimal privacy and utility. The system features partitions on the main spine, intermediate panels, and end panels, creating a consistent, enclosed workspace layout. The partition system stands at a total height of 1200mm and is built using a frame structure with top and side aluminium trims, offering a sleek, modern appearance while maintaining structural integrity. All vertical junctions and corners are finished with high-quality die-cast aluminium caps, ensuring clean detailing and long-term durability. The workstation surface consists of a 25mm thick pre-laminated particle board tabletop, finished on all exposed edges with 2mm PVC edge lipping, enhancing durability and resistance to everyday wear. The tabletop offers ample personal workspace, making it ideal for focused individual tasks within a shared environment. Support for the tabletop is provided through 18mm thick pre-laminated gable ends, offering solid lateral stability while maintaining a minimalist design. The gable ends match the tabletop in finish and style, ensuring a unified look across the workstation cluster. For efficient cable management, the workstation is equipped with a 65mm diameter grommet cap on the tabletop for cable entry. Beneath the surface, a metal raceway tile is provided for mounting electrical switches and sockets, ensuring clean and accessible power connectivity. A metal skirting tile is also included below table level, specifically designed for data cable routing along the main spine, ensuring complete segregation and safety of power and data lines. Tile finishes are thoughtfully planned to enhance both utility and aesthetics. Above table level, the partitions feature fabric tiles, offering tackable surfaces for personal pin-up needs. Each workstation includes one glass marker tile for easy jotting of notes and tasks, and one magnetic tile for pinning magnetic objects or accessories. Below the tabletop, pre-laminated tiles are used for durability and easy cleaning, while metal skirting tiles on the main spine facing the user provide a robust, high-utility finish with integrated cable routing., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 107 Providing & Fixing, MOBILE PEDESTAL 2D1F : 400W X 450D X 600HT The Mobile Pedestal is a compact and durable under-desk storage solution designed for efficient organization of office essentials. With an overall size of 400mm (W) x 450mm (D) x 600mm (H), the pedestal is manufactured from 0.6mm thick Cold Rolled Close Annealed (CRCA) steel sheets, which are powder coated to ensure a high-quality finish that resists corrosion, scratches, and general wear. This unit features a three-drawer configuration, consisting of two box drawers for storing stationery and smaller items, and one filing drawer capable of accommodating hanging files and larger documents. All drawers are mounted on smooth sliding channels, providing seamless and quiet operation during daily use.The pedestal is designed as a mobile unit, equipped with heavy-duty castors that allow for easy movement and repositioning under the workstation or within the workspace. Despite its mobility, the unit maintains structural stability and ergonomic accessibility.A central locking mechanism is integrated into the design, allowing all three drawers to be simultaneously locked with a single key, enhancing document security and user convenience. The compact size allows it to fit easily beneath most standard-height desks while providing ample storage space for individual user needs. This mobile pedestal is an ideal addition to any modern office setup, offering a balance of mobility, functionality, and secure storage. 108 Providing & Fixing, SIDE STORAGE METAL (900X450X1200HT)Supplying and installation of a robust steel almirah designed for office storage applications. The unit shall be installed in a perfectly upright and straight position to ensure alignment, stability, and optimal utility. The overall dimensions of the almirah are 900mm (Width) x 450mm (Depth) x 1200mm (Height), inclusive of integrated legs that elevate the unit off the floor for easy cleaning and enhanced air circulation. The almirah structure is fabricated using high-yield strength Cold Rolled Close Annealed (CRCA) steel sheets of grade D conforming to IS: 513 standards. The door panel is made from 1.0mm thick CRCA sheet, providing added rigidity and durability, while all other structural components are manufactured from 0.8mm thick CRCA sheet to balance strength and weight. For enhanced load-bearing performance, internal stiffeners are integrated within both the shelves and the door, ensuring long-lasting structural integrity and resistance to deformation. Internally, the almirah is equipped with two adjustable shelves, resulting in three loading compartments, each with a clear usable height of approximately 400mm, allowing versatile storage of files, documents, and supplies. The shelves feature a folded construction, which imparts intrinsic rigidity and enhances their load-carrying capacity, capable of supporting up to 40kg of uniformly distributed weight per shelf.The unit is fitted with a steel-hinged door, incorporating a three-way locking mechanism and secured with a 6-lever lock and key. A durable lever handle is provided for smooth and secure operation. All locking components ensure safety of contents and are suited for regular office use.The entire metal assembly undergoes a multi-stage surface treatment process, including iron phosphating for rust resistance, followed by electrostatic powder coating in a finish thickness of 60–80 microns, offering excellent adhesion, abrasion resistance, and aesthetic appeal., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 109 Providing & Fixing, High Back Chairs Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood.Gaslift - Class 4 tested -ANSI BIFMA performance standards.Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002.The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength.Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards.Upholstery: Seat Cushion with pre moulded foam having leatherette tapestery of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Distinctively and characteristically designed tilt mechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratio of 3:7, optimal for good back support.Multilock mechanism is fabricated from CR Sheets, undergo through CO2 welding process imparting uniform surface finish and tensile strength. The components are processed with high degree of precision and care so as to assemble with other parts in perfect harmony to give smooth and effortless reclining experience. Tension springs are made out Grade II material conforming to Indian Standards. Also provided with release levers for locking mechanism and height adjustment of seat. Mechanism aides to operate the height adjustment, and has been equipped with 3 locking positions, back rest “ Return Prevention” function. Back Frame is inserted with leathertte tapestery cushion & Adjustable Lumbar Support.Tension control isbelow the Seat.Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Seat is duly upholstered with approved fabric. Chair will have adjustable headrestChair Should be BIFMA Certified.Seat: Depth- 51.5 cm Width- 44.5 cm Dimensions: Width- 51.5 cm Depth- 53.5 cm Minimum Height- 99.5 cm Maximum Height- 108.5 cm Minimum Seat Height- 44.5 cm Maximum Seat Height- 52.5 cm Width (Arm to Arm)- 66 MODEL, Chair should be BIFMA and Green Guard certified.:- AMAZE HB, Make-Featherlite/Geeken Equivalent. 110 Providing & Fixing, Medium Back Chairs Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood.Gaslift - Class 4 tested -ANSI BIFMA performance standards.Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002.The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength.Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards.Upholstery: Seat Cushion with pre moulded foam having leatherette tapestery of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Distinctively and characteristically designed tilt mechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratio of 3:7, optimal for good back support.Multilock mechanism is fabricated from CR Sheets, undergo through CO2 welding process imparting uniform surface finish and tensile strength. The components are processed with high degree of precision and care so as to assemble with other parts in perfect harmony to give smooth and effortless reclining experience. Tension springs are made out Grade II material conforming to Indian Standards. Also provided with release levers for locking mechanism and height adjustment of seat. Mechanism aides to operate the height adjustment, and has been equipped with 3 locking positions, back rest “ Return Prevention” function. Back Frame is inserted with leathertte tapestery cushion & Adjustable Lumbar Support.Tension control isbelow the Seat.Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Seat is duly upholstered with approved fabric. Chair Should be BIFMA Certified.Seat: Depth- 51.5 cm Width- 44.5 cm Dimensions: Width- 51.5 cm Depth- 53.5 cm Minimum Height- 99.5 cm Maximum Height- 108.5 cm Minimum Seat Height- 44.5 cmMaximum Seat Height- 52.5 cm Width (Arm to Arm)- 66 cm Arm Rest Height- 18- 27.5 cm Chair should be BIFMA and Green Guard certified. AMAZE MB, Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 111 Providing & Fixing, Fixed Leg Chair Made of The frame is made out of 25.4mm tube of 16 gauge tube confirming to IS-7138-1973, Welded by Co2 welding process for uniform surface finish and higher tensile strength perforation on the sheet is of uniform 2.5mm dimension and gives good ventilation.High quality hardware conforming to Hardness 38-44 and tensile strength – 1300 n/mm. IS 1363-1967.Seat is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Japanese T-nuts and riveted in to the plywood.Set and backUpholstery: Cushion with pre-moulded foam of 50 - 60kg/m3 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Injection moulded polypropylene armrests.Leatherette cusion Back on Frame. Back is injected moulded PP.Seat and back are duly upholstered with approved Leatherette. AMAZE VA, Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 112 Providing & Fixing, Single Seater Sofa of Size: 850L X 790D X 790H Seat Foam: the sofa is made up of fine quality leatherette.The structure is made up of silver wood and pine wood.The Seat is made of PU Foam with Density 32 to 40 +/- 2 kg/cu .mtrSeat is upholstered wuth Leatherite.Back Foam: The Back is made of PU Foam with Density 32 to 40 +/- 2 kg/cu, Backis upholstered with Leatherite.Unterstructure is made up of silver wood or pine wood , 4mm Dia zigzag Spring is mounted in the understructure for support and additional cushioning purpose. Legs should be made up of stainless steel tubes/pipes, S-SERIES, Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 113 Providing & Fixing, CORNER TABLE @500 MM DIA, MODEL: CT-2105 MARBLE CORNER TABLE (0.5M), TOP - STONE , BASE - BLACK TIATANIUM. Supplying and installation of a contemporary center table designed to complement modern office and lounge interiors. The table has an overall dimension of 600mm (Length) x 600mm (Width) x 425mm (Height), offering a spacious and proportionate surface suitable for waiting areas, meeting lounges, or collaborative spaces. The tabletop is made from 12mm thick toughened glass, offering high impact resistance and durability. The glass is partially tempered, adding safety features to reduce the risk of sharp breakage. The top profile is square-edged with bevelled edges, enhancing the aesthetics while ensuring user safety through smooth contours and soft corners. The glass top is supported by high-quality vacuum suction caps, securely fixed over the underframe to ensure firm and stable placement without visible fasteners, contributing to a clean, floating appearance. The understructure consists of a stainless steel (SS) frame fabricated from SS 202 grade pipe, known for its corrosion resistance and strength. The pipes used in the frame have a diameter ranging from 20mm to 25.4mm and a wall thickness of 2mm, providing superior load-bearing capacity and structural stability. The frame is finished in a high-gloss chrome finish, offering a sleek, premium look suitable for modern interiors. To protect flooring surfaces and enhance stability, the table is equipped with high-quality PPCP (Polypropylene Copolymer) shoes at the base of each leg. These shoes prevent scratches and scuffs on delicate floors while also absorbing minor impact loads.This center table combines the durability of stainless steel with the elegance of toughened glass, making it a stylish, low-maintenance, and long-lasting addition to any office or hospitality environment., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 114 Providing & Fixing 3 SEATER LEAF TANDOM CUSHION SEAT WITH ARMS Beam & Legs are from uniquely designed MS tubes, the foot are from high pressure diecast aluminium material comes with height adjustable levellers to take care even if there is a floor undulation upto 8-10mm. The Feet, Leg & Beam comes in flat pack, knock down condition and are fixed using zinc passivated best grade hardware. Seat is a plastic injection moulded part in PP material, can be offered with or without cushion & in multiple colours selected from Featherlite shade card based on MOQ. Product can be offered with or without the handle / arms. Arms are from Dia 25mm MS tube fixed with PP arm rest. All Metal & aluminium parts comes with powder coating finish of 60-80 micron thk., Make-Featherlite / Geeken / Hof / Ferris/ Equivalent 115 Providing & Fixing, Steel almirah for office purpose in perfectly upright and straight position. The overall size of the almirah shall be 900mm (W) X 450mm (D) X 2015mm (H) including legs. It should be supplied with 4 nos. of adjustable shelves i.e. 5 loading compartments. Each compartment shall be 400 mm high. Door shall be made of 1mm thick and all other components shall be made of 0.8mm thick high yield strength CRCA sheet of grade ‘D’ confirming to IS: 513. Proper stiffeners shall be provided in shelf & door. The steel hinged door shall be provided with lever handle & 3 way locking mechanism with 6 lever lock with Key. The shelves shall have folded constructions which have intrinsic rigidity and high load carrying capacity.Uniformly distributed load capacity per each shelf shall be 40kg maximum. Metal Part should be pre treated with Iron Phosphating with powder coating of 60-80mm thickness, Make-Featherlite/Geeken Equivalent. 116 Providing & Fixing of high bar stool. Specification : Gimlet of size 480(W)X535(D)X810(H)of Approximately 8 kg weight. Make-Featherlite/Geeken Equivalent 117 FIRE ALARM WORK ESTIMATE 118 supplying , installation , Testing & commissioning of ionization smoke detector with builtin LED and mounting base complete with all connections etc. as required. 119 supplying , installation , Testing & commissioning of manual call boxes of MS construction in surface/recess with strainless steel chain & hammer assembly complete with glass and push button etc. as required. 120 supplying , installation , Testing & commissionin response indicator on surface/recess Ms box having two LEDs mettallic cover complete with all connections etc. as required. 121 supplying , installation , Testing & commissionin fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. 122 supplying , installation , Testing & commissioning of main controland indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement , audio and visual indication for fire alarm and public adress system, monitoring system including connections, interconnections etc complete as required. 10 zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required-2 Nos. ( one to act asstanby) Talk back master stationwith LED PTT ( press to talk ) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/ communication suitable for 20 Nos. talk back unit-1 set. Anouncement control desk suitable for selection of different zones selectively and on ALL CALL switch with visual indication etc. complete as required -1 set Amplifier change over switch for inter changing amplifier -1 No. Monitor panel for loudspeaker complete with output selector, ON/OFF switch, fuse, visual indications etc. complete as required-1 NO. Gooseneck microphone with stand and ON/OFF switch -1 N0. Main ON/OFF switch, fuse indication lamps, DC and AC voltmeter & ammeters , terminal blocks etc. complete as required-1 set Battery charger trickle cum boost to talk complete load of fire alarm PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 60 AH each sealed maintenanance free batteries-1 set. 123 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 4.5 Kg capacity CO2 type as per IS- 15683complete as per specification and fixed / install as per site condition: 124 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 5 Kg capacity ABC Dry Chemical powderas per IS- 15683complete as per specification and fixed / install as per site condition : 125 Supply,Installation, Testing & Commissioning of CI flanged butterfly valve complete with nuts, bolts & washers etc. conforming IS 780 - 100mm dia 126 Supply,Installation, Testing & Commissioning of CI flanged butterfly valve complete with nuts, bolts & washers etc. conforming IS 780 - 80mm dia 127 Supply,Installation, Testing & Commissioning of of ISI marked cost iron double flanged non return valve as per IS: 5312, Part-1 including transportation to work site, supply and fixing nuts, bolts. Gaskets & washers,etc. - 100mm dia 128 Supply,Installation, Testing & Commissioning of sprinkler heads, 25 mm dia conventional pattern, opera table at 68 129 Supply,Installation, Testing & Commissioning of copper cable 2 - core, 1.5 sqmm armoured cable. 130 Supply,Installation, Testing & Commissioning of of PVC insulated 4 core copper cable for connect main pannel to LCP & PA system 131 VRV AIR-CONDITIONING WORK ESTIMATE 132 Shifting of the present vrv connected ac& Fixing at the final location all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 133 Commissioning of VRV systems including topping R410A gas per site requirementsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 134 Supply & Fixing of 1.5 ton AC all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 135 CCTV SURVEILLANCE SYSTEM WORK ESTIMATE 136 Supply, Installation, testing and commissioning of IP fixed Cameras, Network TDN IR Indoor/Outdoor Camera, 1/3 CMOS, 2 MP, 3.6 mm Fixed, 24 IR LEDs,PoE,H.264complete. Make - Dahua 137 Supply, Installation, testing and commissioning of 32 VMS channel NVR with Embedded enterprise grade linux processor, real-time H.265 Security baseline 2.1, 1080p@30 fps adaptive decoding, ONVIF and RTSP protocols, resolution HDMI 4K, AI Face detection, perimeter protection, IVS, people counting, heat map, and SMD, BW 160 Mbps, Audio PCM/G711A/G726/AAC, privacy masking, video loss, scene changing, PIR alarm, SATA III port up to 10 TB. Make Dahua/HikVision 138 Supply, Installation, testing and commissioning of 6TB SATA Internal with 1M hours MTBF, 180 TB workload rate, write-intensive, low bit-rate, high stream-count, prioritized write-op. Make - WD/Seagate 139 Supply, Installation, testing and commissioning of HDBaseT Hdmi Extender Make - Milestone/Bluestream 140 Providing, Installation, Testing & Commissioning of Hig Performance 1.4a standard HDMI 4K Cable. Make - Extron/Nedis/Logic/DC 141 Supply, Installation, testing and commissioning of wall mountable 55 high resolution LED monitor with HDMI port and commercial series suitable for 12x7 operation. All accessories for installation including wall mounting stand/ bracket. Make - Samsung/Sony 142 WIFI & NETWORKING SYSTEM WORK ESTIMATE 143 Supply, Installation, testing and commissioning of 27 U Rack Make - Dlink/Comrack 144 Supply, Installation, testing and commissioning of Rack Accessories For 27U Rack Make - Dlink/Comrack 145 Supply, Installation, testing and commissioning of Metal Shelf Rack Make - Dlink/Comrack 146 Supply, Installation, testing and commissioning of Horizontal Cable Manager Make - Dlink/Comrack 147 Supply, Installation, testing and commissioning of Cat 6 patch panel, loaded. Make - Dlink 148 Supply, Installation, testing and commissioning of modular patch cables 1m 10/100/1000 Make - AMP/Molex/DC 149 Supply,Installation, testing and commissioning of 24 port POE switch 10/100/1000. Make - Dlink/Netgear 150 Supply, Installation, testing and commissioning of Dual Band Wave Wifi 6 Access Points. Make - Grandstream 151 Supply,Installation, testing and commissioning of cat6 Informatio0n Outlets, non PCB Pyramid type. Make - Dlink/Amp/Molex 152 Supply, Installation, testing and commissioning of Dual Face Plates with clear labeling. Make - Dlink/Amp/Molex 153 Supply, Installation, testing and commissioning of FDB LIU patch panel, loaded. Make - Syrotek 154 Supply, Installation, testing and commissioning of modular patch cables 5mMake - Syrotech/Dlink
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
35.
Housing Urban and Rular Development #9488962 Technical Bid
Tender For Construction Of Administrative Building Of Cyber Thana At Gauriganj Distt Amethi - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 1.5 m to 3.0 m). 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 3.0 m to 3.3 m). 4 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeupto/aboveplinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 10 Foundations, footings, bases of columns, etc. for mass concrete. 11 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. 12 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 13 Columns,Pillars, Piers, Abutments, Posts and Struts. 14 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 15 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 16 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction Of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(Part II 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shall be as follows ; (1)Treatment for masonary & foundation 5 liters per/ 100 sqm. (2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4)Treatment junction of wall and the floor 7.5 liters/100 sqm (5)Treatment Of soil along external perimeter of building 7.5 liters/100sqm. (6) Treatment Of soil under apron along external perimter 5 liters/100 sqm. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 19 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 20 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 21 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 22 Half brick masonary with common burnt clay ( non modular) bricks of class - 150in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) 23 Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete. 250mm x 16mm . 24 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 250mm x 10mm . 25 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 150mm x 10mm . 26 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm 27 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm 28 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 29 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. 30 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 31 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 32 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 33 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 34 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick 35 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 36 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 37 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 38 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 39 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 40 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 41 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 42 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 43 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 44 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. 45 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections 46 Cement plaster skirting up to 30 cm height,18 mm thick, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement. 47 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 48 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 49 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster 50 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 51 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 52 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm [IN FLOORING] 53 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.complete.Size of Tile 600x600 mm 54 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm 55 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 56 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 57 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement 58 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ .90 kg/ 10 sqm) 59 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 60 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 61 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 62 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 63 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 64 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 65 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 66 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 67 Coupler 110 mm 68 Bend 87.5° 110 mm bend 69 Shoe (Plain)110 mm Shoe 70 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 71 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry 72 Supply and filling of light weight cinder filling in sunken portion of 1st floor toiletincluding watering ramming etc, complete the cost of including material and labour 73 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth 74 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 75 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 76 For vertical surface two coats @ 0.70 kg per sqm 77 For horizontal surface one coat @1.10 kg per sqm. 78 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) 79 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 80 Providing and fixing bright /matt finished Stainless Steel D Type handles of approved quality & make with necessary screws etc all complete. 600 mm long 25 mm dia 81 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum Water tank 82 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 83 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 84 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 85 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 86 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 87 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 88 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe i) 32 mm dia 89 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 90 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 91 Providing and fixing toilet paper holder :C.P. brass 92 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 93 90 mm O.D. 94 110 mm O.D. 95 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 96 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 97 90 mm size 98 110 mm size 99 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.BEND 87.5° 75 mm Shoe 100 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 101 90x90x90 mm size 102 110x110x110 mm size 103 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 104 90 mm size 105 110 mm size 106 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 107 90 mm size 108 110 mm size 109 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 110 90 mm size 111 110 mm size 112 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 113 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 114 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 115 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.cement and testing of joints complete as per direction of Engineer in charge Internal work - Exposed on wall 116 20 mm nominaldia pipes 117 25 mm nominaldia pipes 118 40 mm nominaldia pipes 119 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 120 15 mm nominal outer dia pipes 121 20 mm nominal outer dia pipes 122 25 mm nominal outer dia pipes 123 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 124 25mm dia, nominal bore 125 32 mm dia, nominal bore 126 40 mm dia, nominal bore 127 50 mm dia, nominal bore 128 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore 129 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 130 20 mm nominal bore 131 25 mm nominal bore 132 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore 133 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 134 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 135 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 136 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 137 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 138 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : 139 Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight offrame 15 kg) 140 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg(weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 141 Extra for depth of man hole size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 142 Providing and fixing square mouthS. W. Gully trapSP 1 complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type 143 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 144 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 146 50mm nominal bore. 147 40mm nominal bore. 148 32mm nominal bore. 149 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 150 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 151 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 152 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 153 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 154 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 155 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 156 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 157 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 158 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 159 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 160 5/6 A switch 161 3 pin 5/6 A socket outlet 162 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 163 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 164 Supplying and fixing (75mmX75mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module ) 165 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 166 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 167 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 168 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 169 Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 170 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 171 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 172 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 173 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 174 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 175 4 way (4 + 12), Double door 176 6 way (4 + 18), Double door 177 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 178 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 179 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 180 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 181 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 182 40 A 183 63 A 184 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 185 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 186 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 187 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 188 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 189 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypePower Panel :Incoming -200 Amp MCCB - 1 No.Outgoing - 40 Amp 4P MCCB - 4 Nos.63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No.(Complete as per requirment directed by Project Manager.) 190 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 191 Supply & fixing of IP 20, Frount Mid Power SMD type LED LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 192 Supply & fixing of IP 20, Mid Power SMD type LED1*1 square LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 193 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 194 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 195 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 196 size 6 sq mm x 2 core 197 size 70 sq mm x 3-1/2core 198 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 199 2 X 6 sq. mm (19mm) 200 3½ X 70 sq. mm (32mm) 201 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 202 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 203 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 204 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 205 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 206 Supply and fixing of 600 mm long cross arm of 50 mm x 50 mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on wall Complete in all respect. 207 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 Watt. Confirming to IP 65 Protection complete in all respects. CAT AAA 208 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 209 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop 210 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 211 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 212 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 213 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 214 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 215 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 216 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 217 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 218 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 219 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m HeadTerrace Pump 220 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 221 80 mm dia 222 100 mm dia 223 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 224 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 225 80 mm dia 226 100 mm dia 227 Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 228 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 229 80 mm dia 230 100 mm dia 231 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 232 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 233 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 234 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 235 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 236 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 237 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 238 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 239 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 25 sq. mm (28mm) 240 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 241 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 242 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 243 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 244 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 245 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 246 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 247 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 248 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 249 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).750x600x250 mm ( Cabinet) 250 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :63 Amp, 35kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. -1 Set 251 Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. 252 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 253 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 254 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). 255 Providing and fixing in position pre-moulded joint filleProviding and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charger in expansion joints. 256 Providing and filling in position rubberized bitumen hot sealingcompound for sealing of expansion joints in roads / pavementsall complete as per direction of the Engineer-in-Charge. 257 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 258 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-3016.78.1 259 Supply andfixingM.S.Workingate includingall necessary forproper completion of the work. 260 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 261 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 262 Providing & fixing 75mm dia vent pipes.Centrifugally cast (spun) iron socketed pipe asper IS: 3989 263 Providing & fixing of 75mm dia cast iron terminal guard.Sand cast iron S&S as per IS - 3989 264 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 500 mm internal diameter 265 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 266 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 300 mm dia all kinds of soil 267 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 mm dia 268 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 269 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm Nominal Size dia 270 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 271 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm Dia 272 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp 273 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm Dia 274 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 50 mm nominal size dia 275 Supply and Installation of 3.0 HP Submersible pump set complete 276 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia 277 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 278 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 279 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 280 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 281 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 282 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 283 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 284 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 285 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG/cm^2 286 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 287 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 288 Steel work welded in built up sections framed work,including cutting, hoisting ,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required .in grating ,frames,guard bar,ladder,railings,brackets,gates and similar works. 289 Supply and installation testing and commisioning of IP based EPBX system comprising of core switch & 1.2 switches 16 port EPBAX IP 4 trunk 290 Hand set IP 291 Master handset IP 292 Supplying and drawing of UTP 4 pair CAT 6 Lan cable 293 POE (Power over ethernet) 294 1 kva UPS 295 R1 4510 box with key stone 296 6U rack comrax (45x45x35 cm) DVR 297 PDU (Power distribution unit)) 298 Fan 299 Supply, Installation, Testing & Commissioning of Wireless indoor Access Point Combined data rate support Dual 5GHz 4.8 Gbps, 802.11ax, 2.4 GHz/5GHz: 4x4: 455 WiFi 6, data rate upto 2400 Mpbs. Four 2.4 GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omni Bluetooth Antenna, Transmit Beamforming and Maximal Ratio Combining the WLAN Access Point solution should have Integrtaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and honeypot Access Point detection, able to create WYLAN policies. The solution should be artifical intelligence based self healing soltion. Bluetooth®LE and toTsensor support Humidity pressure (Wi-Fi SYSTEM)Temperature, should also support Asset Tracking if required in future without any change in Hardware. 300 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 301 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping. The canopy temperature shall not exceed 7 degree above the alternator shall be brushless type excited and self regulated continously rated as follows, 3 phase 415 volts 50cycles, 4 wire system and shall be provided with static excitation unit, alternator insulation shall be class H or better to withstand tropical conditions and shall generally comply with relevant IS and present by-laws under average conditions the voltage regulation shall be within ± 1.5%. The overload capacity shall not be less than 110% for one hour in every 12 hours. The set shall be mounted on a common bed plate with antivibration mounting and alternator shall be suitable for LT AL XLPE cables connection and alternator shall be suitably modified and similarly provision shall be made in the canopy to take out AL XLPE cables DG Set Compatible for synchronising Panel 35 KVA 302 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 35 sq mm x 3-1/2core 303 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 35 sq. mm (32mm) 304 Supply, Installation, Testing & Commissioning of Armoured 06 Core Singlemode (OS2) 9/125 Fiber Cable, ITU G 652.D, G657A1, Outdoor ECCS Armored Fiber Cable with PBT Loose Tube Filled With Thixotropic Jelly. Uni-Tube, Glass Yarn, Water Swellable Tape Under Armor UV-HDPE Jacket Approved Makes. Derwiser/Nexans Siemen Sistiman 305 Supply, Installation, Testing & Commissioning of 6 Port IU x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummer/Glands to close any open entry, Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices, Tube for open fibers, Thes, Panel shall be Powder Coated with Min 12mm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1, IEC-60754-1. Insertion loss <= 0 35 dB. Return Loss >= 50. Attenuation 1310/1550 10 3/0 2 dB/KM. Repeatability <= 02DB 1000 Tunes Mating Cycles, RoHS Complied. Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 306 Supply. Installation, Testing & Commissioning of 24 Port 10 x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummet Glands to close any open entry. Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices. Tube for open fibers. Ties, Panel shall be Powder Coated with Min | 2trm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1. IEC-60754-1, Insertion loss <= 0 35 dB, Return Loss >= 50. Attenuation 1310/1550 03/02 dB/KM. Repeatability <= 0 2DB 1000 Times Mating Cycles, RoHS Complied, Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 307 Supply. Installation, Testing & Commissioning of fiber patch cord. LC-LC Spiral steel armored 9/125mm OS2 singlemode round cord (4.0 +/- 0.mm).Duplex approved makes Derwiser/Nexans/Stemon/Systimax 308 Supply. Installation, Testing & Commissioning of Cat 6A, 23 AWG (0 57.003mm) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tape or Metallic Shield inside. Connectivity of Hub room to End Point Approved Makkes Derviser/Nexans/Stemon/Systimax 309 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack. ISO/IEC 11801 2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C 2 Category 6A, IEC 60603-7 (603-7). Universal 110 Impact Tool & Tooless (Both) Termination, Min 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fi at user end Approved Makes Derwiser Nexans Siemon Systimax 310 Supply, Installation. Testing & Commissioning of loaded 24 port CAT 6A UTP. Transparent shutter ack panel, IU height, UL-94V-0, cicar label marks and earthing plug for CAT6A cable termination at rack end No Approved Makes Derwiser Nexans Siemon Systimax 311 Supply, Installation. Testing & Commissioning of Cat6A Putch Cord [TP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm. 1 Meter. Operating Temperature -20 to +60 Deg C Patch cord | Mtr for rack side swatch to jack panel connectivity Approved Makes. Derwiser/Nexans/Stemon/Systimax 312 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm, 3 Meter. Operating Temperature -20 to +60 Deg C Patch cord 2 Mtr for rack side switch to end user connectivity Approved Makes Derwiser Nexans/Siemon/Systimax 313 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone TypeShuttered Faceplates for 1/0 fixing at user side Approved Makes Derwiser/Nexans Stemon/Systimax 314 Supply, Installation, Testing & Commissioning of 42 U (600W/1000D) floor mount rack with fans, 2 cable managers, salationary shelf, 2 Nos of hardware pkts Approved Makes Derwiser MIS Rata/APC/APW 315 Supply, Installation, Testing & Commissioning of 22 U floor mount rack with fans. 2 cable managers satationary shelf. 2 Nos of hardware pkts Approved Makes Derwiser/MTS/Rital/APC/APW 316 Supply, Installation. Testing & Commissioning of 15t/ wall mount rack with fans, 2 cable managers. satationary shelf. 2 Nos of hardware pkts Approved Makes Der Wiser/MIS/Rittal/APC/APW 317 Supply, Installation, Testing & Commissioning of Core Switch with switching capacity of 12 Tbps, forwarding performance of 1000 Mpps with 24x 1/10G SFP+ ports expandable to 40 SFP+ ports with 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, Stacking/Virtual Chasis support upto 9 Switches with bandwidth 140 Gbps, 64K IPv4 and IPv6 Routes and 30K multicast routes MAC Address 250K, Jumbo frame 9000 bytes should support Routing protocols (KIPng OSPF v3, IS-IS v6, BGPv6) with 1 year support Should be Common Criteria/NDPP/NDCPP certified & IPv6 Logo Certified OEM should be Leader in Forrestor SDN & Gartner Data Centre latest report Approved make - Cisco / Juniper / Impulse / Nexxus/Arista 318 Supply, Installation, Testing & Commissioning of 12 Port POE+ Access Switches with switching capaticy of 200 Gbps, forwarding performance 150 Mpps, having 24 x 10/100/1000BASE-1 Pol-plus(RJ45) with minimum PoE budget of 370 W, with 4 x 10G SFP+ uplink ports Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address Should have Static Routing. Neighbor discovery, system logging. Telnet, SSII, SNMP, Network Tune Protocol (NTP), Domain Name System (DNS) and IPv6 features from day I and should support OSIF, VRRP, OSPFv3 and PIM Approved make - Cisco/Juniper / Impulse/Nexxus/Arista 319 Supply, Installation. Testing & Commissioning of fiber Modules 10G BASE Approved Make Cisco/Juniper / Impulse/Nexxus/Ariste 320 Supply. Installation, Testing & Commissioning of Wireless Indoor Access Point Combined data rate support Dual SGHz 4.8Gbps, 8021lax, 24 GHz/5GHz 4x4 4SS WiFi 6, data rate upto 2400 Mpbs. Four 2.4GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omn: Bluetooth Antenna Transmit Beamforming and Maxımal Ratio Combining the WLAN Access Point solution should have integriaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and 1 honeypot Access Point detection, able to create WxLAN policies The solution should be artifical intelligence based self healing soltion Bluetooth LE and loTsensor support Humidity Pressure Temperature, should also support Asset Tracking if required in future without any change in Hardware Omni-directional Bluetooth Antenna, superbeacon mode with iBeacon and Eddystone, OFDMA & BSS Coloring support Operating temp 0 to 40 degree. Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse/Nexxus/Arista 321 Supplying Installation Testing & Commissioning of Wifi & Dual Band Ax 1800 (WAVE2, MU MIMO, 802 11AX (2x2)) with 2 5 Gbps Poe+ Port Mesh Access Point as required at site. Approved Make Cisco/Juniper / Impulse/Nexxus/Arista/Netgear 322 Supply. Installation, Testing & Commissioning of Wireless Controller Should be Artificial Intelligence (AI) driven Microservices based architecture. The Solution should support 802.11ac primarily and should be backward compatible to 802 | In/a/b/g The solution should also support 802 | lax with Guest Portal support, support WIPS, Rouge AP detection and Honeypot AP detection, able to provide insights based on Time to connect, successful connect, coverage, capacity, AP Uptime, Roaming and throughput able to integrate with varous authentication mechanism including the RADIUS servers, able to handle interference and shift the communication on another channel automatically if, needed, support Dynamic Packet capture to enhance troubleshooting Microservice based Architecture should be scalable to handle around 5000 APs or more in future, Should have a virtual assistant to troubleshoot deeper and facilitate investigation of existing or future issues in the Wi-Fi network Artificial Intelligence feature should be manageble from Wireless to Switching devices Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse / Nexxus/Arista 323 Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with15*3mmlugs 10 cmlong embededded in cement concreteblocks 15*10*10cmof 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) orwithwooden plugs and screwsor rawlplugsand screws or with fixing clipsorwith bolts and nutsas require including fixing ofnecessarybut hingesand screws and applying a priming coat of approved steel primer. 324 ANGLE IRON90*90*6 mm 325 T-SECTION 90*90*6 326 HOLD FAST40*6 FLAT 327 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. G.I. Pipe(80 MM DIA)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
36.
Housing Urban and Rular Development #9475635 Technical Bid
Tender For Tourism Development Of Kabir Dhuni/Gorakh Talaiya At Sahjanwa Distt. Gorakhpur - Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 3 Filling of carted earth. 4 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 5 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 6 Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. 7 (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 8 (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 9 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN LINTEL] 10 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN BEAM] 11 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN SLAB] 12 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN COLUMN] 13 R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN FOOTING] 14 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 15 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 16 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 17 Same as in item No. 11 abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) 18 Ground Floor 19 First Floor 20 Same as in item no. 14 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 21 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars 22 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. 23 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand 24 Ground Floor 25 First Floor 26 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 finesand. 27 Ground Floor 28 First Floor 29 Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required. 30 Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. 31 Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. 32 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm (Flooring) 33 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm (Skirting) 34 Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm [IN FLOORING] 35 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment 36 Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). 37 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 38 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood 39 Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable doublenylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. 40 Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares anddrainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 41 Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) 42 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) 43 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 44 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Ceiling) 45 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 46 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. 47 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 48 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 49 (a) 250 mm x 10mm 50 Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. 51 Providing & laying brick coba 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cm x cm and side wall parapet shall be mono tythic plaster wall upto 30 cm higher and junction 52 and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acelic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc complete for proper completion of work. 53 Painting with synthetic enamel paint of approved brand and manufacture of required colourto give an even shade : 54 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 55 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 56 Construction of drain alongwith apron. 57 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 58 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc.p 59 Centering and shuttering including strutting, propping etc. and removal of form for : 60 (a) Foundations, footings, bases of columns, etc. for mass concrete 61 (b) Suspended floors, roofs, landings, balconies and access platform 62 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 63 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 64 Providingandfixingtiledfalseceilingofspecifiedmaterialsofsize 595x595mmintruehorizontallevel,suspendedoninterlockingmetalgrid ofhotdippedgalvanizedsteelsections(galvanized@120grams/sqm, bothsideinclusive)consistingofmain“T”runnerwithsuitablyspaced jointstogetrequiredlengthandofsize24x38mm madefrom0.30mm thick(minimum)sheet,spacedat1200mmcentertocenterandcross “T”ofsize24x25mmmadeof0.30mmthick(minimum)sheet,1200 mmlongspacedbetweenmain“T”at600mmcentertocentertoform agridof1200x600mmandsecondarycross“T”oflength600mmand size24x25mmmadeof0.30mmthick(minimum)sheettobeinterlocked atmiddleofthe1200x600mmpaneltoformgridsof600x600mmand wallangleofsize24x24x0.3mmand layingfalseceilingtilesofapproved textureinthegridincluding,requiredcutting/making, openingforservices likediffusers,grills,lightfittings,fixtures,smokedetectorsetc. 65 Main“T” runnerstobesuspendedfromceilingusingGIslottedcleatsofsize27x 37x25x1.6mmfixedtoceilingwith12.5mmdiaand50mmlongdash fasteners,4mmGIadjustablerodswithgalvanisedbutterflylevelclipsof size85x30x0.8mmspacedat1200mmcentertocenteralongmainT, bottomexposedwidthof24mmofallT-sectionsshallbepre-paintedwith polyesterpaint,allcompleteforallheightsasperspecifications,drawings andasdirectedbyEngineer-in-charge. 66 12.5mmthicksquareedgePVCLaminatedGypsum Tileofsize595x595mm,madeofGypsumplasterboard, manufacturedfromnaturalgypsumasperIS2095part|and laminatedwithwhite0.16mmthickfireretardantPVCfilm onthefacesideand12micronmetalizedpolyesteronthe backsidewithalledgessealedwiththefacesidePVCfilm whichgoesaroundandwrapstheedgesandisbondedto theedgesandthebacksidemetalizedpolyesterfilmsoasto makethetileacompletelysealedunit. 67 Internal Electrification (Yatri Hall) 68 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 69 Group C 70 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 71 Submains : 72 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 73 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 74 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 75 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 76 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 77 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 78 20 mm 79 25 mm 80 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 81 5/6 A switch 82 3 pin 5/6 A socket outlet 83 TV antenna socket outlet 84 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 85 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 86 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 87 1 or 2 Module (75mmX75mm) 88 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 89 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 90 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 91 Upto 450 mm sweep 92 MCBs & DB’s : 93 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 94 4 way (4 + 12), Double door 95 6 way (4 + 18), Double door 96 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 97 4 way (4 + 12), Double door 98 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 99 Single pole 100 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 101 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 102 100 A,30KA,FPMCCB 103 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 104 Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A 105 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 106 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 107 ELCB/RCCB Switches : 108 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 109 40 A 110 63 A 111 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 112 Earthing Work : 113 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 114 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 115 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 116 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 117 100 mm width X 50 mm depth X 1.6 mm thickness 118 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 119 Lighting Fixtures (Lights/Fans) : 120 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 121 Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . 122 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 123 Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter complete in all respect. 124 Armoured Cables (Cable/Gland/Lug) : 125 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 126 size 25 sq mm x 3-1/2core 127 size 35 sq mm x 3-1/2core 128 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable 129 size 25 sq mm x 3-1/2core 130 size 35 sq mm x 3-1/2core 131 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 132 size 25 sq mm 133 size 35 sq mm 134 L.T. Switch Panel Board : 135 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. 136 The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. 137 The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type 138 Incoming - 139 200 Amp MCCB-1 No. 140 Outgoing - 141 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DBs) 142 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DBs) 143 63 Amp 4P MCCB - 1 Nos. (for Terrace pump)) 144 40 Amp DP MCB - 2 Nos. (Spare) 145 (or As per requirment directed by Project Manager.) 146 Non-Schedule Items 147 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 148 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 149 INTERNAL SANITARY (Yatri Hall) 150 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required 151 W.C. pan with ISI marked white plastic seat and lid 152 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 153 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. 154 Providing and fixing wash basin with C.I. brackets, 15 mm dia C.P. brass Single Hole Basin Mixture approved quality and make ,including painting of fittings and brackets, cutting and making good the walls wherever require. 155 a)White Vitreous China wash basin size 550x 400 mm with 15 mm dia C.P. brass Single Hole Basin Mixture. 156 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 157 Semi rigid pipe 158 a) 32mm dia 159 b) 40mm dia 160 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 161 Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 162 15mm nominal bore 163 Providing and fixing CP Brass 32 mm sizeBottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. 164 Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. 165 a) 15mm dia nominal dia. 166 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 167 a) 100 mm diameter 168 Providing and fixing Toilet paper holder 169 a) C.P. brass 170 Providing & fixing 600x120x5 mm glass self with edges round off, supported on anodiesd aluminium angle framewith C.P. brass bracket and guard rail complete fixed with 40 mmlong screws, rawl plugs etc, complete. 171 Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. 172 Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. 173 Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. 174 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 175 110mm diameter 176 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 177 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 178 110mm 179 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 180 Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. 181 (internal work) 182 Exposed on wall 183 32mm dia nominal bore 184 Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 185 32mm dia nominal bore. 186 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 187 internal work -Exposed on wall 188 20mm dia nominal outer dia pipes 189 25mm dia nominal outer dia pipes 190 32mm dia nominal outer dia pipes 191 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. 192 Concealed work including cutting chases and making good the walls etc. 193 15mm dia nominal outer dia pipes 194 20mm dia nominal outer dia pipes 195 25mm dia nominal outer dia pipes 196 Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 197 15mm nominal bore 198 Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 199 15mm nominal bore 200 Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 201 Providing and fixing gun metal gate valve with wheel of approved quality. 202 25mm dia nominal bore 203 20 mm dia nominal bore 204 32mm dia nominal bore 205 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 206 25 mm nominal bore 207 Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 208 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, 209 in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. 210 Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. 211 Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 212 100mm diameter 213 150mm diameter 214 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 215 100mm diameterS.W. Pipe 216 150mm diameterS.W. Pipe 217 Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 218 150 x 100 mm. size P type 219 With Sewer bricks conforming to IS : 4885 220 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 221 Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). 222 With FPS bricks of class designation 75 223 (i) For Sewer Line 224 Extra for depth of man hole size 90x80 cm 225 Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. 226 Extra for depth of man hole size 90x120 cm 227 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design 228 With 20x20 mm square bar 229 EXTERNAL WATER SUPPLY SYSTEM 230 Provding and fixing gun metal non return valve of approved quality (screwed end) 231 50 mm nominal bore 232 Vertical 233 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. 234 External work 235 32mm nominal bore. 236 50mm nominal bore. 237 Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. 238 32 mm diameter pipe 239 50 mm diameter pipe 240 Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 241 32 mm nominal bore 242 50 mm nominal bore 243 Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : 244 With F.P.S. bricks 245 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 246 25 to 40 mm dia nominal bore 247 50 to 80 mm dia nominal bore 248 Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. 249 90 mm O.D. 250 110 mm O.D. 251 Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. 252 Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. 253 Size 90 mm 254 Size 110 mm 255 Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. 256 Size 75/90 mm 257 Size 110 mm 258 Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. 259 Size 90x90x90 mm 260 Size 110x110x110 mm 261 Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. 262 Size 90 mm 263 Size 110 mm 264 FIRE FIGHTING 265 (A) Supplying, Installation, Testing & Commissioning ofElectric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump) 266 (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520. 267 (C) Suitable HP Squirrel cage indution motor, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, confirming to IS-325. 268 (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. 269 (E) Suitable cement concrete foundation duly plastered with anti vibration pads. 270 450 lpm at 35 m head 271 Providing, laying, testing & Commissioning ofC class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 272 25 mm dia 273 100 mm dia 274 Supplying & fixing single headed internal yard hydrant valve with instantaneousGunmetal/Stainless Steel coupling of63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: 275 Single headed Gunmetal 276 Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 277 100 mm dia 278 Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required: 279 Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 280 100 mm dia 281 Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: 282 Gun Metal 283 Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. 284 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 285 20 mm nominal internal dia gun metal globe valve & nozzle. 286 Drum and brackets for fixing the equipments on wall. 287 Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 288 30 m 289 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. 290 Gun Metal 291 Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 292 Providing & fixing of pressure switch in M.S. pipe line including connection etc as required. 293 Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 294 FIRE DETECTION & ALARM SYSTEM 295 Supplying, installation, testing & commissioning of Manual call Boxes of MS constuction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 296 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box(16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. 297 Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 298 Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 299 25mm 300 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilityes as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 301 4 Zone 302 Providing, laying, testing & Commissioning ofC class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 303 80 mm dia 304 100 mm dia 305 Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: 306 Single headed Gunmetal 307 Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 308 80 mm dia 309 100 mm dia 310 Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 311 100 mm dia 312 Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: 313 Gun Metal 314 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. 315 Gun Metal 316 Supplying & fixing ofFire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: 317 2 way-100 mm dia M.S. Pipe 318 Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 319 Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 320 Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete.Make : Standard/Lifeguard or EQ. 321 Supplying and fixing of Fire man axe.Make :- Agni Suraksha (ASES) or EQ 322 Supply, Installation, Testing and Commissioning of electronic siren with suitable audible range of 1 k.m. approximately 4 watt.complete in all respects. Make :- Agni Suraksha (ASES) or EQ. 323 Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprisingof :a) 40 amp 3 Pole MCCB, 50Hz with breaking capacity 10KW.b)One Volt meter (0-500 V) with selector switch.c) One set including lamps.Make :- Make :- Agni Suraksha (ASES)/ABB/L&T or EQ. 324 SEPTIC TANK & SOAK PIT 325 Size :- Length = 5.00 M. Width = 2.00M Total Depth =3.00M 326 Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. 327 In all kind of soil upto 1.5m depth 328 In all kind of soil upto 1.5m to 3.0m. depth 329 In all kind of soil upto 3.0m to 4.5m. depth 330 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20mm nominal size) 331 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 332 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) including centering and shuttering and reinforcement. 333 TMT Fe-500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 334 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) 335 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 336 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 337 Providing & fixing 75mm dia vent pipes. 338 Providing & fixing of 75mm dia cast iron terminal guard. 339 M.D. -10- Circular shape 500mm internal diameter 340 M.D. -2.5- Circular shape 450mm internal diameter 341 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. 342 With F.P.S. bricks 343 Centering and shuttering including strutting, propping etc. and removal. 344 UPGRADATION OF BOUNDRY WALL (519.20 RM) 345 R.C.C. work in Beam 346 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 347 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 348 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick workbending for proper shap as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured. 349 M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls not to be less than 1-1/2 brick. including supply of all materiallabour, Tools & Plants etc.required for proper completion of the work 350 12 mm cement plasterinsingle coat on fair sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth.(1)1 cement:6 fine sand 1.25 F.M. 351 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm 352 Steel reinforcement for R.C.C. work ready to use “cut and bend” rebars of approved make fromfactory/workshop to construction site includin placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more. 353 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 354 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture 355 Centering and shuttering including strutting, propping etc. and removal of form for 356 Lintels, beams, plinth beams, girders, bressumers andcantilevers 357 Centering and shuttering including strutting, propping etc. and removal of form for 358 Column 359 COST OF SIGNAGE /INTERPATION WALL about theme of Kabir das gurunanak ravidas & Guru Gorakhsh Nath & Sant Keshavdas (CIVIL WORK) (07 Nos) 360 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 361 Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation. 362 R.C.C. (M-20) work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. 363 As in item 3 abovebut inR.C.C.beamwithapproved stone ballast.(Using1:1.5:3Mix concrete) 364 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in footing excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 365 R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in columns excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) 366 P/F TMT Bar -Fe 500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 367 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 368 Red sand stone - Exposed face machine cut and table rubbed with rough backing. 40 mm thick 369 Centering and shuttering including strutting, propping etc. and removal of form for : 370 (a) Foundations, footings, bases of columns, etc. for mass concrete 371 (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers 372 (c) Columns, Pillars, Piers, Abutments, Posts and Struts 373 INTERLOCKING PAVER front side parking (971.50 sqm) 374 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) 375 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 376 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 377 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge. 378 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern 379 SAND STONE PATHWAY (arround kund & green area) 1631 SQM) 380 Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) 381 Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 382 M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 383 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone 384 HORTICULTURE AND LANDSCAPING 385 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 386 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 387 Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). 388 Supplying and stacking well decomposed cow dung manure at site including royalty and carriage upto site (cow dung measured in stacked will be reduced by 8% for payment.) 389 Anti termite treatment of lawn area through premise 30.50% I P. one literpremise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. 390 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 391 GRASS PLANTING WORK 392 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge 393 GROUND COVER/ PLANTING WORKS 394 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 395 SHRUB PLANTING WORKS 396 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) 397 Holes 60 cm dia, and 60 cm deep 398 Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. 399 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 400 Providing and stacking of Ficus blackii (F.vivion) of height 45-60 cm. with 6- 8 branches healthy foliage in earthen pots of size 25 cm as per direction of the officer-in-charge. 401 Providing and Displaying Ficus black vivion piller Topiary (sylinder type) well developed with fresh & healthy 180 to 210 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge. 402 Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 403 Providing and Displaying Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type well developed in 50 cm Cement Pot as per direction of the officer-in-charge. 404 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 405 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. 406 External water suplly from submersiblepump (85 RM) (Detail As per TS Estimate) 407 GAZIBO (2 Nos) 408 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 409 Filling of Carted earth 410 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 411 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 412 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 413 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 414 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 415 R.C.C. work in slab 416 R.C.C.work in beams 417 R.C.C.work in footing foundation 418 R.C.C.work in Column 419 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 420 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 421 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 422 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 423 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 424 15 mm cement plaster on rough side of single or half brick wall of mix: 425 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 426 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 427 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 428 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 429 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 430 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,V epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 431 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 432 Centering and shuttering including strutting, propping etc. and removal of form for : 433 (a) Foundations, footings, bases of columns, etc. for mass concrete 434 (b) Suspended floors, roofs, landings, balconies and access platform 435 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 436 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 437 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 438 Red sand stone - Exposed face machine cut and table rubbed with rough backing 439 ELECTRICAL WORK 440 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 441 Group C 442 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 443 Submains : 444 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 445 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 446 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 447 20 mm 448 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 449 5/6 A switch 450 3 pin 5/6 A socket outlet 451 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 452 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 453 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 454 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 455 MCBs & DB’s : 456 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 457 4 way (4 + 12), Double door 458 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 459 Single pole 460 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 461 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 462 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 463 ELCB/RCCB Switches : 464 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 40 A 466 Earthing Work : 467 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 468 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 469 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 470 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 471 Non-Schedule Items 472 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 473 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 474 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 475 PLUMBING WORK 476 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 477 110 mm 478 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 479 110 mm 480 [GAZIBO ] EXTRA HEIGHT (02 Nos) 481 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 482 Filling of Carted earth 483 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 484 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 485 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 486 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 487 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 488 R.C.C. work in slab 489 R.C.C.work in beams 490 R.C.C.work in footing foundation 491 R.C.C.work in Column 492 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 493 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 494 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 495 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 496 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 497 15 mm cement plaster on rough side of single or half brick wall of mix: 498 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 499 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 500 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 501 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 502 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 503 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,V epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. 504 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 505 Centering and shuttering including strutting, propping etc. and removal of form for : 506 (a) Foundations, footings, bases of columns, etc. for mass concrete 507 (b) Suspended floors, roofs, landings, balconies and access platform 508 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 509 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 510 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) includingpointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps andpins which shall be paid for separately) : 511 Red sand stone - Exposed face machine cut and table rubbed with rough backing 512 ELECTRICAL WORK 513 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 514 Group C 515 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 516 Submains : 517 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 518 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 519 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 520 20 mm 521 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 522 5/6 A switch 523 3 pin 5/6 A socket outlet 524 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 525 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 526 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 527 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 528 MCBs & DB’s : 529 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 530 4 way (4 + 12), Double door 531 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 532 Single pole 533 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 534 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 535 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 536 ELCB/RCCB Switches : 537 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 538 40 A 539 Earthing Work : 540 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 541 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 542 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 543 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 544 Non-Schedule Items 545 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 546 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 547 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 548 PLUMBING WORK 549 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 550 110 mm 551 Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 552 110 mm 553 COST OF STONE BENCHE (Supply, and fixing in position 3 seater sand Stone Benches, 1800*600*450 mm at site as per approved quality and design. including all cost of accesories, transportation etc. complete in all respect.) (Detail As per TS Estimate) 554 SOLAR LIGHTall in one Philips (Detail As per TS Estimate) 555 CONTROLLING WATER LOSSES IN GORAKH TALAIYA KUND 556 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. 557 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green.Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. 558 HDPE SHEET 1 Layer at pond bottom(800 MICRON) 559 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III) including manufactured sand derived fromRecycled Concrete Aggregate (RCA) upto 25% : 3 graded stone aggregate 20 mm nominalsize including Recycled Concrete Aggregate (RCA) upto 25%). 560 Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 561 MINI POND & CONNECTION 562 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. 563 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 564 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) 565 Raised and cut pointing on stone work in white cement mortar 1:3 (1 white cement : 3marble dust). 566 Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressedstones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately). 567 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 568 400 mm dia 569 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design 570 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover108 kg and weight of frame 100 kg) : 571 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 572 (i) For PIPE Line 573 Extra for depth of man hole size 90x120 cm 574 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 575 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 576 For pipes 350 to 450 mm diameter 577 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete 578 450.mm diameter 579 Boring 580 T.W. boring of 200 mm dia with 150 mm dia P.V.C. pipe assembly, 7.50 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangements complete. 581 8 PVC casing pipe of ISI mark. 582 P/ F 3 GI pipe (B) class. 583 Nylon mesh for filter. 584 Plastic dori. 585 Solvent cement. 586 8 End cap. 587 8 Submersible cap. 588 3 MS clamp (Heavy). 589 3 GI elbow. 590 3 X 6 GI nipple. 591 7.5 HP 9 Stage submersible pump of ISI mark with automatic panel. 592 4.00 sqm. Submersible cable. 593 Drilling charges for16 dia tubewell. 594 Pea Gravel. 595 2 MS socket. 596 Rope with plastic coated 597 Cartage of material upto site. 598 water collection tank at ground lvl(haudi) 599 Shop 01 Nos 600 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 601 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 602 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 603 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 604 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. 605 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 606 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 607 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 608 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 609 R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 in Lighter Beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. 610 R.C.C. Work IN FOOTING 611 R.C.C. Work in column 612 M-150 brick work in one cement & 6 coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. 613 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 614 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 615 M-150 Brick work in super-structure above plinth level up to floor two level (up to two storeys) includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) 616 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 617 Providing & laying brick Coba 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of 618 coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick 619 ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. 620 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 621 35 mm thick (Single Leaf) 622 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) both Side 623 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 624 Hold fast for chaukhats of doors/windows. 625 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a) Second class teak wood 626 TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 627 Fixing of Door, windows/ventilators chaukhats in position. 628 (a) Door 629 15 mm thick plaster with cement mortar in proportion of 1:4 (1 cement: 4 coarse sand) cement & coarse sand in plinth. 630 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 631 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand. 2.25.F.M. 632 12 mm cement plaster in ceiling to finshed even and smooth with mix of 1 cement : 3 coarse sand. 633 Addforplasterdripcourse/grooveinplasteredsurfaceormouldingto R.C.C.projections. 634 Ground & First floor 635 40mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. 636 Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. 637 Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. 638 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 639 Granite of any colour and shade (Area of slab over 0.50 sqm) 640 Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3, Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt, dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. 641 Same as item above but on new wood surface. 642 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 643 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) 644 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 645 Supplying and fixing rolling SHUTTERS of approved make made 80x125mm (3x5) cold rolled M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs. 646 Providing and fixing ball bearing for rolling shutters. 647 Red Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 40 mm thick 648 S.S.Cramp 649 Making of draing along with apron 150 X 150 MM 650 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter 651 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion. 110 mm bend 652 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 653 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 654 Centering and shuttering including strutting, propping etc. and removal of form for : 655 (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers 656 (b) Suspended floors, roofs, landings, balconies and access platform 657 (c) Foundations, footings, bases of columns, etc. for mass concrete 658 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 659 ELECTRICAL WORK 660 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 661 Group C 662 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 663 Submains : 664 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 665 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 666 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 667 20 mm 668 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 669 5/6 A switch 670 3 pin 5/6 A socket outlet 671 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 672 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 673 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 674 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 675 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 676 Upto 450 mm sweep 677 MCBs & DB’s : 678 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 679 4 way (4 + 12), Double door 680 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 681 Single pole 682 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 683 Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A 684 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 685 ELCB/RCCB Switches : 686 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 687 40 A 688 Earthing Work : 689 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 690 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 691 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 692 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 693 Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA 694 Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. 695 S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. 696 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 697 EARTH FILLING ON SITE 698 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 699 High Mast Light 700 Supply & Installation of High Mast 12.0mtr. Long with 180 watt LED 6 No. fitting with IP 65 Protection complete in all respect.(Including Panel) 701 supply and fixing of 15 amp SPN automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors ,HRC fuse,isolating switch,metering instrument,and instrument box with CTs etc.complete in all respect. 702 Cables 703 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size 704 size 6 sq mm x 2 core 705 size 10 sq mm x 4 core 706 size 25 sq mm x 3-1/2core 707 Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable 708 size 6 sq mm 709 size 10 sq mm 710 size 25 sq mm 711 Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable 712 size 6 sq mm 713 size 10 sq mm 714 External Painting on Existing Building 715 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 716 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (Inner walls) 717 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 718 Scraping old whit & colour wash including disposal of refuse as directed by the Engineer-in-charge with in a distance of 60m (Inner Wall) 719 SAND STONE FLOORING ON POND STEP & CHABUTRA EXTENSION & GRANIET FLOORING 720 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone 721 S.S. RAILING 722 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. 723 Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm [IN FLOORING] 724 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 725 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). 726 M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 727 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 728 Centering and shuttering including strutting, propping etc. and removal of form for : 729 (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers 730 DRAIN 300X450 (LENTH =75+30.6 +117.7+45.7 MTR) (269 RMT) 731 Earth work in excavation 732 P.C.C. 1:4:8 733 Brick work in 1:4in foundation. 734 12 MM thick plaster (1:4) 735 C.C. flooring 736 DISMATELLING & RECONSTRUCTION OF BOUNDRY WALL TWO PANNEL FOR HYDROLIC MECH. ( 5.120 Rmt.) 737 As per Details TS Estimate 738 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 739 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 740 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick workbending for proper shap as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured. 741 M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls not to be less than 1-1/2 brick. including supply of all materiallabour, Tools & Plants etc.required for proper completion of the work 742 12 mm cement plasterinsingle coat on fair sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth.(1)1 cement:6 fine sand 1.25 F.M. 743 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm 744 Steel reinforcement for R.C.C. work ready to use “cut and bend” rebars of approved make fromfactory/workshop to construction site includin placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more. 745 As per Details TS Estimate 746 Two or more coats on new work over an under coat of suitable shade with ordinary paint ofapproved brand and manufacture 747 Centering and shuttering including strutting, propping etc. and removal of form for 748 Lintels, beams, plinth beams, girders, bressumers andcantilevers 749 Centering and shuttering including strutting, propping etc. and removal of form for 750 Column 751 Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 752 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge. 753 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. cum 494.10 Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 754 WALL CUTTING 755 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 756 a) 110mm diameter 757 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing completeso as to make it leak proof. 758 KITCHEN 759 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 760 Filling of Carted earth 761 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. 762 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 763 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground 764 floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm 765 (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. 766 R.C.C. work in slab 767 R.C.C.work in beams 768 R.C.C.work in footing foundation 769 R.C.C.work in Column 770 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 771 M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. 772 Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. 773 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 774 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 775 15 mm cement plaster on rough side of single or half brick wall of mix: 776 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 777 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand 778 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 779 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) 780 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 781 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 782 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 783 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 784 Centering and shuttering including strutting, propping etc. and removal of form for : 785 (a) Foundations, footings, bases of columns, etc. for mass concrete 786 (b) Suspended floors, roofs, landings, balconies and access platform 787 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 788 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 789 Providing & laying brick coba 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cm x cm and side wall parapet shall be mono tythic plaster wall upto 30 cm higher and junction 790 and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acelic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc complete for proper completion of work. 791 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut withthe zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 792 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut withthe zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. 793 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 794 (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 795 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. 796 Hold fast for chaukhats of doors/windows. 797 Door / windows & Staircase grill. 798 Angle iron chaukhats size 40x40x5 799 Z Section steel window 800 Fixing of Door, windows/ventilators chaukhats in position. 801 (a) Door 802 (b) Windows 803 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). 804 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 805 Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. 806 Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. 807 (a)250 mm x 10mm 808 (a) 200 mm x 10mm 809 Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. 810 Wiringforlightpoint/fanpoint/exhaustfan point/callbellpointwith1.5sq.mmFRLSPVC insulatedcopperconductorsinglecorecablein surface/recessedmediumclassPVCconduit, withmodulartypeswitch,modularplate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 811 Group C 812 Wiringforcircuit/sub-mainwiringalongwith earthwirewiththefollowingsizeofFRPVC insulatedcopperconductor,singlecorecablein surface/ recessedmediumclassPVC conduitasrequired. 813 2X1.5 sqmm + 1x1.5 sqmm earth wire 814 2X2.5 sqmm + 1x 2.5 sqmm earth wire 815 2X4.0 sqmm + 1x 4.0 sqmm earth wire 816 2X6.0 sqmm + 1x 6.0 sqmm earth wire 817 Supplyinganddrawingco-axialTVcableRG-6 graded,0.7mmsolidcopperconductorPE insulated,shieldedwithfinetinnedcopperbraid andprotectedwithPVCsheathintheexisting surface/ recessed steel/ PVC conduit asrequired. 818 Say Rs. 819 Supply and fixing of following size of PVC conduitalongwiththeaccessoriesinrecess includingpaintingincaseofsurfaceconduit,or cuttingthewallandmakinggoodthesameincase of recessed conduit as required: 820 20mm 821 Supplyingandfixingfollowingmodularswitch/ socketonthe existingmodularplate&switch boxincludingconnectionsbutexcludingmodular plate etc as required. 822 TV antenna socket outlet 823 Supply and fixing of stepped type electronic fan regulatorontheexistingmodularplateswitch boxincludingconnectionsbutexcluding modular plate etc. as required. 824 Supplying and fixing modular blanking plate on the existing modular plate & switch boxexcluding modular plate as required. 825 Supplying and fixingfollowing size/modules,GIboxalongwithmodularbase &coverplate for modular switches in recess etc as required. 826 1 or 2 module(75mm X 75 mm ) 827 SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modularsocketoutletand5/6Amodularswitch,connection etc. as required. 828 SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. 829 Supplyingandfixing3pin5Aceilingroseon the existing junction box/woodedn blockincluding connectionetc. as required. 830 Supplyingandfixingbrassbatten/angleholderincluding connectionetc. as required. 831 Instalation,testing&commissioningofwall bracket/ceilingfittingsofallsizesandshapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories includingconnection etc. as required. 832 Installation, testing and commissioning of prewired,flourescentfitting/compact fluorescent fitting of all types,completewithall accessoriesandtubesetc.directlyonceiling/ wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. 833 Installation, testing and commissioning of ceiling fan,includingwiring thedownrodsof standard length(upto30cm)with1.5sq.mmFRLSPVC insulated, copper conductor, single core cable etc. Includingprovidingandfixingphenolic laminated sheet cover on the fan box etc. asrequired. 834 Numbering of ceiling fan/ exhaust fan/fluorescent fittings as required. 835 Installationofexhaustfanintheexisting opening, including making good the damage, connections, testing, commissioning etc. as required. 836 upto 450 mm sweep. 837 Extraforfixingthelouvers/shutterscomplete with frame fro exhaust fans of all sizes. 838 Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB,`C`curveincludingconnections,paintingetc. as required. 839 Providing and fixing circular/Hexagonal cast ironorM.S.sheetboxforceilingfanclamp,of internal dia 140 mm,73mmheight,top lidof 1.5 mmthickM.S.sheetwithitstopsurfacehacked for proper bonding, top lid shall bescrewed into the cast iron/M.S. sheet box by means of 3.3 mm diaroundheadedscrewed,onelocatthe conrners.Clampshallbemade of12mmdiaM.S. bar bent to shape as per standard drawing. 840 Supply,Installation,TestingandCommissioning of1200mmsweep,BEE5starrated,ceilingfan with Brush Less Disect Current(BLDC) motor, classofinsulation:B,3nos.blades,30cmlong down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9,ServiceValue(CM/M/W)minimum6,Airdelivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than10%remoteorelectronicregulatorunitfor speedcontrolandallremainingaccessories including safety pin, nut bolts, washers, temperaturerise=75degreeC(max.),insulation resistancemorethan2megaohm,suitablefor 230V,50Hz,singlephaseACSupply,earthingetc. complete as required. 841 Supplyingandfixing following way,singlepole and neutral sheet steel, MCB distribution board, 240Vonsurface/recesscomplete with,tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthingetc. asrequired(ButwithoutMCB/ RCCB / Isolators). 842 12 way, Double door 843 Supplying and fixing 5 amps. to 32 amps. rating,240volts `Cseries, miniaturecircuit breaker (MCB)suitableforinductiveloadof following poles in theexisting MCB DB completewith connections,testingand commissioningetc.as required. 844 Single Pole 845 Double Pole 846 Supplyingandfixingsinglepole,blankingplate intheexistingMCBDBcompleteetc.asrequired. 847 EarthingwithGIearthpipe,600mmX600 mmX 6 mm thick including accessories and providingmasonaryenclosurewith coverplate having locking arrangementandwateringpipe of 2.7 metre long etc, with charcoal/cock and salt as required. 848 Supplying and Laying of 25 mm X 3 mm G.I strip at0.50metrebelowgroundasstripearth electrode, including connection / terminating withnut,bolt,spring,washeretc.asrequired.( jointing shall be done by overlapping and with 2 setsofG.I.nutbolt&springwasherspacedat50mm) 849 Supplying and Laying of 6 SWG G.I wireat 0.50 metre belowgroundlevelforconductorearth electrode, including connection / terminating with G.I. thimble etc. as required. 850 LayingofonenumberPVCinsulatedandPVC sheathed/XLPEpowercableof1.1KVgradeof following size direct in ground including excavation,sandcushioning,protectivecoveringand refilling the trench etc. as required. 851 Upto 35 sq. mm 852 Supplying&makingendterminationwithbrass compressionglandandaluminiumlugsforthe following size of PVC sheathed / XLPE aluminiumconductorcableof1.1KVgradeasrequired. 853 2 X 10 sqmm. (19mm) 854 Providing,layingandfixingfollowingdiaG.I. pipe(mediumclass)ingroundcompletewithG.I. fittings including trenching (75 cm deep) andrefilling etc as required. 855 50 mm Dia(Rate taken From Civil DSR 2021-18.12) 856 Supplyoffollowingsizeof1.1KVgrade multicore aluminium conductor PVC sheathedarmoured cable as per IS 1554. 857 10 sqmm 2 core 858 Supply & fixing of7/9 W LED BULB complete inall respect. 859 Supply and fixing of LED Tube Light with battensuitableforupto1X20wattLEDtube light complete including tube etc. on surfacecomplete in all respect. 860 Supply&fixingofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down LighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespects. 861 Cat. AAA 862 Supply ofAC230/250Volts,50Hz55w1400 rpm exhaust fans including providing nuts, bolts, mountingframeandotheraccessoriesincluding connections etc. complete as required.-Make:Havells-STANDARD -Refresh Air-SPS 863 300mm sweep. 864 PLUMBING WORK (As per TS Estimate 865 DRINKING WATER BOOTH 866 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 867 Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. 868 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 869 M-150 brick work in one cement & 6 coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. 870 R.C.C. work in slab (Using1:1.5:3Mix concrete) 871 As in item 5 abovebut inR.C.C.beamwithapproved stone ballast.(Using1:1.5:3Mix concrete) 872 As in item 5 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. 873 As in item 5 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast. (Using1:1.5:3Mix concrete) 874 Class M-150 Brick work in super-structure above plinth level includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than one brick thick. (1:4 cement & coarse sand) 875 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 876 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (Fe-500) 877 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete Granite of any colour and shade 878 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) 879 Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) 880 Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. 881 Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 882 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 883 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :(15 mm dia) 884 Providing and fixing G.I. Union in G.I. pipeincluding cutting and threading the pipe and making long screws etc. complete (New work) :(15 mm dia) 885 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.(25 mm dia) 886 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 887 Supply of 110 mm dia PVC casing pipe for boring 6 kg/sqm ISI approved. 888 WATER TANK 889 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust)with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 890 Red Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 40 mm thick 891 Centering and shuttering including strutting, propping etc. and removal of form for : 892 (a) Foundations, footings, bases of columns, etc. for mass concrete 893 (b) Suspended floors, roofs, landings, balconies and access platform 894 (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers 895 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 896 GST Extra As per Applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Uttar Pradesh View Result →
37.
Public Administrative Department #9463829 Technical Bid
Tender for the remaining work (development work and electrification work) of Sanskriti School under construction under CG City Scheme, 1 ROAD WORK 2 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. DSR 16.1 3 Construction of granular sub-base by providing close graded Materialspreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. PWD SOR 4 Providing and laying design mix cement concrete of M-30 grade, inroads/ taxi tracks/ runways, using cement content as per designmix, using coarse sand and graded stone aggregate of 40 mm nominalsize in appropriate proportions as per approved & specified designcriteria, providing dowel bars with sleeve/ tie bars wherever required,laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdyM.S. channel sections, curing, making provision for contraction/expansion, construction & longitudinal joints ( 10 mm wide x 50 mmdeep) by groove cutting machine, providing and filling joints withapproved joint filler and sealants, complete all as per direction ofEngineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement content in M-30 is @ 340 Kg/Cum. Excess/Less cement Used as per design mix is separately.DSR 16.43.2 5 Providing and fixing in position pre-moulded joint filler in expansion joints.DSR 16.45 6 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD SOR 504 7 PARKING 8 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.DSR 16.1 9 Construction of granular sub-base by providing close graded Materialspreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. PWD 10 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturers specifications & direction of Engineerin-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. DSR 16.91.2 11 Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. DSR 16.63 12 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarsesand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment. (Precast C.C. kerb stone shall be approved by Engineer-in-charge). DSR 16.69 13 DRAIN 14 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.DSR 2.8.1 15 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)DSR 4.1.8 16 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level DSR 5.33.1 17 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD 504 18 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) DSR 13.7.1 19 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25.2 20 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work DSR 13.61.1 21 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.DSR 23.9 22 COLUMN UPTO 10 FT 23 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6. 24 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work,including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto plinth level DSR 5.37.1 25 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1 26 RETAINING WALL 27 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. DSR 2.8.1 28 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 29 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 30 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 31 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size). DSR4.1.6 32 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 33 Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. DSR 5.9.2 34 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 35 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1 36 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 37 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1 38 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm DSR 22.23.2 39 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone. DSR 22.1.1 40 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone DSR 22.2.1 41 SKYLIGHT & BRICK WORKS 42 Providing & fixing of roof with multilayer standing seam polycarbonate panel system of 18mm thickness (min) including all standard fixing accessories on top of the supporting structure (paid extra) complete & as per the direction of the engineer in charge. The panels should work on angular daylighting concept with translucent and opaque combination of louvers inside, for better thermal insulations and diffusion of light especially with white and clear combination designed for tropical regions & shading throughout the day for better ambient temperature below the roof. Panels shall have minimum seven layers with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. The entire panel system shall be with a width from min 1200mm. Bigger width and minimal junctions should be preferred for better performance. Panels shall be manufactured with vertical offset standing seam at both sides of the panel. Panels have to be fixed on purlin with snap on connectors with grip lock double tooth locking mechanism and will be secured on MS Structure/ purlins (will be paid separately) with HDSS Fastener and double tooth polycarbonate connector for best stability and having a pull-out load of min 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Panels cell structure be in truss bridge design or commonly called X structure for better strength and stability. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on polycarbonate panel which have been exposed to UV for a min. of 500 hours as per ASTM G155. Panels shall not have yellowness Index as per ATSMD 1925 of 15 units when tested on a sample exposed to UV for 500 hours as per ASTM G 155. U value shall not be more than 2.0W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cp/ Aluminium U/F profile/ Glazing Bar (all mill finish) for ends as required. Trained and factory authorized layout with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge.Colour: as per approval. 43 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 44 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2 45 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR 13.4.2 46 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) DSR 13.5.2 47 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 48 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) DSR 13.46.1 49 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 50 CHAIN LINK FENCING 51 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. DSR 2.8.1 52 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 53 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 54 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 55 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) DSR 4.1 56 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 57 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 58 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1 59 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 60 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade DSR 16.70.2 61 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel rimer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes DSR 10.16 62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 63 M.S. GRILL WORKS 64 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding DSR 9.48.1 65 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece DSR 10.5.2 66 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 67 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25 68 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 69 BASEMENT WORK 70 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 71 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 72 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 73 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). DSR 4.1.10 74 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick DSR 11.26.1 75 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 76 BASKETBALL COURT 77 Concrete Base:-Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation . 78 Synthetic Specification: -Providing and laying of ITF Classified material. 8 layers System Synthetic Acrylic for Synthetic Basketball Court:-(1 layer) Conrete Primer(2 layer) Resurfacer(3 layer) Cushion Rubber(4 layer) Top CoatWhite Line Marking as per standard 79 Basketball pole fix type 6” round pipe , Projection 2*20 Acrylic board 20mm Malaysia with dunking ring (3 spring) 80 Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P. 81 Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit. 82 SPORTS FACILITIES 83 LAWN TENNIS COURT 84 Concrete Base:-Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation . 85 Synthetic Specification: -Providing and laying of ITF Classified imported material (AcryCoat Made In Europe)8 layers System Synthetic Acrylic for Synthetic Court :-• (1 Layer) Concrete Primer • (2 layers) Acrylic Resurfacer• (3 layers) Cushion • (2 layers) Top Coat•Line Marking 86 Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P 87 Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit. 88 Pole socket type 80*80 mm , thickness (4 mm) with net 89 SKATING RING 90 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.DSR 16.1 91 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverableseparately). DSR 16.75 92 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksDSR 10.25.2 93 Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign mater;al etc. and lining out complete.New work (Two or more coats) DSR 16.47.1 94 HORTRICULTURE AND LANSCAPING 95 Supply and stacking of of good earth at site including royaltyand carriage up to 1 Km DSR 2.2 96 Supply and stacking of sludge at site including royalty and carriage up to 1 Km DSR 2.3 97 Supply and stacking of dump manure from approved source at site including carriage up to 1 Km DSR 2.4.3 98 Rough dressing the trenched ground including breaking of clods DSR 2.5 99 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.6 100 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.7 101 Spreading of sludge, dump manure and or good earth and mixing as per direction of engineer incharge DSR 2.8+2.9 102 Grassing with selection No-1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn. free from weeds and fit for moving and disposal of rubbish as directed DSR 2.10.1 103 Half brick circular treeguard in brick 1.25 m internal dia and of ht 1.20 m above ground and 0.20 m below ground..... DSR 2.15 104 Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. DSR 2.54 105 Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. DSR 2.56 106 Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag of size 25 cm as per direction of the officer-in-charge DSR 7.5 107 Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge DSR 7.24 108 Supply and stacking of Ficus bengalensis (Bargad) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR 7.28 109 Supply and stacking of Ficus elastica Decora (Rubber plant) plant of height 45-60 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.DSR 7.31 110 Supply and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-incharge DSR 7.63 111 Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180- 195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge. DSR 7.75 112 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge DSR 2.28 113 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge DSR 2.33 114 Plumbing Detail 115 SANITARY FIXTURES 116 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. DSR 17.1.1 117 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. DSR 17.78 118 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.. DSR 17.80 119 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31 120 Providing and fixing toilet paper holder : C.P. brass DSR 17.34.1 121 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single holebasinmixer. 122 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm. DSR 17.10.1.1 123 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore DSR 18.53.1 124 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore DSR 18.51.1 125 Providing and fixing brass stop cock of approved quality : 15 mm nominal bore DSR 18.16.1 126 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 127 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. MR 128 Providing and fixing of SS coat hook complete in all respect as approved by Engineer In Charge MR 129 Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.DSR 17.70.1 130 Providing and fixing of SS grab bar complete in all respect as approved by Engineer In Charge MR 131 Providing and fixing urinal partition chinaware complete in all respect MR 132 Providing and fixing of sink mixer complete in all respect. MR 133 Providing and fixing SS labourtory sink as per detailMR 134 Providing and fixing laboratory sink mixer complete in all respect.MR 135 Providing and fixing drinking water sink complete in all respects MR 136 SOIL , WASTE AND VENT SYSTEM 137 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings: 75 mm dia 138 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings : 100 mm dia 139 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings : 150 mm dia 140 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Hubless : 100 mm inlet and 100 mm outlet DSR 17.60.1 141 Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia. DSR 18.58.1.1 142 Providing and fixing floor clean out plug consist of CI bend & GI socket heavy class with Brass cap & key for opening male threaded cap etc. including lead caulked to CI pipescomplete in all respects as per drawing / sample approved by Engineer -in -ChargeFCO (floor clean out plug shall be flushed with floor finish: 100 mm dia/150 mm dia 143 Water Supply system 144 Inside Toilets 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work. DSR 18.9 146 15 mm nominal outer dia. Pipes. 147 20 mm nominal outer dia. Pipes. 148 25 mm nominal outer dia. Pipes. 149 Distribution lines 150 Providing and fixing of GI Pipes medium class IS :1239 including all required fittings etc. DSR 18.12 151 20 mm dia. nominal bore 152 25 mm dia. nominal bore 153 32 mm dia. nominal bore 154 40 mm dia. nominal bore 155 50 mm dia. nominal bore 156 65 mm dia. nominal bore 157 80 mm dia. nominal bore 158 100 mm dia. nominal bore 159 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore DSR 18.13.1 160 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore DSR 18.13.2 161 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). DSR 18.14 162 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore: DSR 18.17 163 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. DSR 18.17.2 164 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore DSR 18.17.3 165 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore DSR 18.17.4 166 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore DSR 18.17.5 167 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore DSR 18.17.6 168 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore DSR 18.18.1 169 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore DSR 18.18.2 170 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore DSR 18.18.3 171 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 172 Providing and fixing submrsible vertical drainage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control.Status (w+s)1 working + 1 stand bysolid hanldling 40 mm size.discharge 5 lps and head-15 mtr 173 Providing and fixing submrsible vertical sewage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control.Status (w+s)1 working + 1 stand by solid hanldling 40 mm size.discharge 5 lps and head-15 mtr 174 RAIN WATER SYSTEM 175 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 100 mm dia 176 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 150 mm dia 177 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 200 mm dia 178 Making of 600x600 mm size khurah complete in all respects including water proofing etc. 179 EXTERNAL SEWARAGE AND DRAINAGE 180 GARDEN IRRIGATION 181 Providing and fixing HDPE pipes conforming to IS:4984 PE 63 Class IV (6 kg/sqcm) including all fittings, e.g.couplings, tees, bends, reducers and screwed adoptors, welded joint as per manufacturers recommendations. 182 a) 32 mm O.D. 183 b) 40 mm O.D. 184 c) 63 mm O.D. 185 Providing and fixing uPVC Schedule 40 pipes conforming to ASTM D-1785complete with uPVC Schedule 40 fittings including necessary cutting of pipes, jointing with HDPE pipe with sadddle fitting completewith testing and commissioning of pipe lines : (a) 1 nominal size 186 Providing and fixing 25 mm brass dia quick coupling valve fitting with auto-close lid, SS spring, brass valve, complete in all respects (Harit model HT-71Bor eq.). 187 Providning and fixing bronze ball valve with screwed female/flangedends with stainless steel valve and spindle, glass fileed tefelon seating and gland packing, quarter turn lever operate full bore design, hydraulically tetsed to 20 kg/sqcm 188 a) 25 mm nominal bore 189 b) 40 mm nominal bore 190 a) 50 mm nominal bore 191 Providing and fixing cast iron flanged wafer type butterfly Valve with quarter turn operation complete in all respects confirming to IS:13095 PN1.0: (a) 65 mm dia 192 Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. cover 500x450 mm R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design. 193 Providing and fixing 15 mm N.B. air release valve alongwith FTA I/c 1 no. ball valve for fixing to HDPE pipeline complete 194 Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. surface box 100 mm top dia 160 mm bottom dia and 180 mm deep (inside) with chained lid and R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design. 195 SEWERAGE 196 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia. 197 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (b)Extra over 1 (a) above for excavation over 1.5 m depth . 198 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (a) 200 mm OD 199 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (b) 250 mm OD 200 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (c) 300 mm OD 201 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. :(a) 200 mm OD 202 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. (b) 250 mm OD 203 Providing and fixing square mouth S.W. gully trap grade A complete with C.I. Grating brick masonary chamber with bricks of class designation 75 and water & gas tight SFRC Cover with frame of 260x260 mm size clear opening, frame of size 390x390 mm with weight of frame to be not less than 10 Kg and cover of size 300x300 mm with weightof cover not to be not less than 9 Kg as per standard design: (a) 180X 150 mm size P type with F.P.S. bricks of class designation 75 204 Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks 205 Extra for depth beyond 45 cm of brick masonary chamber : for 455X610 mm size : With F.P.S. bricks 206 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand)inside cement plaster 12mm thick with cement mortar1:3 ( 1 cement :3 coarse sand ) finished with floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement 3 Coarse sand: 6graded stone aggregate 40mm nominal size) and making necessary channelin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) finished witha floating coat of neat cement all complete as per standard design: 0.91 m deep with SFRC cover and frame ( Heavy duty HD-20 gradedesignation) 560mm internal diameter conforming to IS:12592 total weightof cover and frame to be not less than 182 kg, fixed in cement concrete1:2:4 (1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. (excavation, foot rests and 12 mm thick cement plaster at the surface shall be paid seperately): with F.P.S. bricks class desigantion 75 207 Extra depth for circular type manhole 0.91 m internal dia (at bottom) with beyond 0.91 m to 1.67 m, withF.P.S. bricks class designation 75 208 DRAINAGE SYSTEM 209 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia. 210 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (b) Pipes, cables etc. exceeding 300 mm dia. 211 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(a) 200 mm OD 212 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(b) 250 mm OD 213 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(b) 300 mm OD 214 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (a) 200 mm OD 215 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (b) 250 mm OD 216 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cementand making channelsin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) neatly finished witha floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (a) Inside size 90X80 cms and 60 cms deep including SFRC cover with frame (heavy duty) 500 mm dia clear opening 217 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cementand making channelsin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) neatly finished witha floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (b) Inside size 120X90 cms and 90 cms deep including SFRC cover with frame (Extra heavy duty) 560 mm dia clear opening. 218 Extra for additional depth of manholes: (a) Size 90X80 cms beyond 60 cms depth 219 Extra for additional depth of manholes: (b) Size 120X90 cms beyond 90 cms depth 220 Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks 221 Constructing brick masonary road gully chamber 50X45X60 cm with bricksof class designation 75 in cement mortar 1:5 (1 cement: 5 fine sand) including 500X450 mm precast RCC horizontal grating with frame complete as per standard design:With F.P.S. bricks 222 Making connection of stormwater lines with existing municipal manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: (a) For pipes 250 to 450 mm diameter 223 FIRE FIGHTING WORKS 224 FIRE FIGHTING 225 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(a) 80 mm dia ( 4.85mm thickness) 226 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(b) 100 mm dia ( 5.40mm thickness) 227 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(c) 150 mm dia ( 5.40mm thickness) 228 Supply, Installation, Testing and Commisioning of butterfly valve suitableforworking pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts&gasketscomplete required.:(a) 100 mm dia 229 Supply, Installation, Testing and Commisioning of butterfly valve suitableforworking pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts&gasketscomplete required.:(b) 150 mm dia 230 Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitableforworking pressureof15 Kg/Sqcm & test pressure 30kg/sqcm withflanges, Nut, bolts & washers, painting etc.completeas required.:(a) 100 mm dia 231 Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitableforworking pressureof15 Kg/Sqcm & test pressure 30kg/sqcm withflanges, Nut, bolts & washers, painting etc.completeas required.:(b) 150 mm dia 232 Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:( a) 65 mm dia 233 Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:(b) 150 mm dia 234 Supply, Installation, Testing and Commisioning ofC.I.`Y strainer with bronzeperforatedsheetbasket includingrubber gasket, flanges, nuts, bolts and washers, complete as required.: (a) 150 mm dia 235 Supply, Installation, Testing and Commisioning of SS single head fire hydrant valvewith80 mm N.B.flangedinlet, brass spindal, one no. 63 mm dia femaleinstantaneousoutlet type. G.M. coupling,blank cap, chain. Conforming to IS:5290.Includingtappingfromwet riser complete as required. 236 Supply, Installation, Testing and Commisioning ofHose pipe, 63 mm diaand15mts long, duly reinforced, rubberlined suitable forbrusting pressurenot lessthan22Kg/Sqcm. conformingtoIS 636-1988type A with gun metal heavy dutyinstantaneous type coupling ( Pairmale&femaleparts) conforming to IS 903. Complete as required. 237 Supply, Installation, Testing and Commissioning of63 mm dia instantaneouspattern branchshort SSpipe,16 mmdia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required. 238 Supply, Installation, Commisioning of standard firemans axe with heavy rubber handle. 239 Supply, Installation, Testing and Commissioning ofinletbreaching havingC.I.bodyfourway SS 63 mm diainstantaneousinlets conforming toIS 903fittedwithnon returnvalves, 25 mm diagun metal drain cock, blank cap, brasschains and 150 mm dia flanges with allaccessories suitableforlocal fire tender complete as required. 240 Supply, Installation, Testing and Commissioning ofSS Fire Brigadeadopter assemblywith150mm diaoutlet,suitableforlocalfire tender complete as required. 241 Supply, Installation, Testing and Commissioning of weather proof cabinet of size not less than0.6 x 0.6 x 0.45 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.)suitably markedon the outside with the letters FIRE HOSE including necessary lockingarrangement and painting in red coloursuitableto accomodate, externalyard hydrant valve, 2 nos15 mtrlongHose pipe, branch pipe, nozzle and fire mans axe. It shall be mounted on boundary wall complete as required. 242 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.: Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.: M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 70 m Head 243 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump): Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.: 2280 lpm at 70 m Head 244 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) : Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.: Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.: M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.: Suitable cement concrete foundation duly plastered and with anti vibration pads. : 180 lpm at 70 m Head 245 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 246 INCOMING:250A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTs etc:LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300AOUTGOING:( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 247 Jockey Pump : 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL 248 Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 249 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe 250 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 251 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. 252 FINISHING WORK 253 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) DSR 21.1.1.2 254 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Powder coated aluminium (minimum thickness of powder coating 50 micron)DSR 21.1.2.2 255 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides DSR 21.2.2 256 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness: DSR 21.3.2 257 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125x75x4 mm: DSR 9.95.1 258 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm: DSR 9.96.1 259 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm: DSR 9.97.1 260 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm: DSR 9.100.1 261 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.: Twin rubber stopper: DSR 9.101.2 262 Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturers specification.: Two or more coats on new work: DSR 13.42.1 263 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. (Material shall conform to ASTM 6063). : Floor Joint of 100 mm gap: DSR 5.44.1 264 Providing and fixing of expansion joint system related with wall joint (internal / external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.): Wall Joint of 100 mm gap:DSR 5.45.1 265 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) : Roof Joint of 100 mm gap : DSR 5.46.1 266 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 267 CONNECTING BRIDGE 268 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer allcomplete. DSR 10.2 269 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25 270 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62 271 ROOF SKYLIGHT -18 mm THK POLYCARBONATE SHEET Supply and Installation of polycarbonate multi-layered, Multicell Xfix Connectible modular panel system for, a complete assembly of coextruded UV protected polycarbonate panels incorporated into a complete system. Standing seam polycarbonate panel system of minimum 18 mm thick (Min.) Panels with bigger width will be preferred for reducing number of joints in the roof.Panels shall be with grip lock double tooth lockingmechanism with interlocking connectible connectors running lengthwise at both sides of the panel. Panels shall be fixed on Purlins of MS tructure (will be paid Separately) with self-drilling screws and specialsTrapezoidal Heavy Duty Fastener/ Al- Cleat to ensure a pull-out load of min. 7000N (7KN) testedas per ISO 6892:1998 and IS 1608: 2005. The min width of the panel system shall be 900mm (min.). 272 Panels shall be uniform in color UV protected in combination with seven layers for required lux level, along with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels with morelayers will be preferred for better insulation and improved shading coefficient. Prices includes All accessories including Aluminum profiles with EPDM Gaskets, at alternate edges with taper cutting to achieve the required profile, aesthetics and performance criteria. U value shall not be more than 1.8 Watt/m2K as per EN ISO 1077- 2:2018 and respective third Party test certificate shall be produced before procurement. 273 Panels shall have an X cell structure also called truss bracing design to have more strength and flexibility simultaneously. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G155.Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factoryauthorized labour with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge. 274 LEVELLING 275 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. SOR 2.31 276 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.32 277 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.33 278 Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.: Beyond 60 cm girth upto and including 120 cm girth: SOR 2.33.2 279 EXTERNALELECTRICAL 280 COMPACT SUB STATIONS - 01 (with OLTC) 281 Supply, Installation, testing and Commissioning of 11 kV / 0.415 KV Compact Sub Station(with OLTC)outdoor plinth mounted type designed for natural cooling having type tested equipment comprising distribution transformers, SF6 insulated VCB compact switchgear (RMU) having metal enclosed robotically sealed/welded stainless steel tank , L T Panel, interconnection between HT switchgear & Transformer using single core cables and Transformer to LT switchgear using Al bus bars/Cables factory built / ready for connection type, otherassociated equipment etc. complete as required conforming to detailed specification. 282 The enclosure shall have modular construction usingG.I. sheets and shall be painted with polyurethane paint from the exterior of approved shade. The enclosure for LT switchgear & HT switchgear shall be provided with IP54ingress protection. The transformer compartment will have IP23 ingress protection. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment.Transformer compartment door shall be interlocked with HT breaker.The transformer used shall be specially designed for low losses and shall be hermetically sealed & with corrugated tank. 283 The L T ACB shall have inbuiltmicroprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases with Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947 284 L T Panel BUS : 415 Volts, 3 phase 50 HZTPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C. 285 The Transformer losses should confirm to IS - 1180 Part-1 (2014) efficiency Level - 2[ 1.86 KW at 50% load & 5.3 KW at 100% load shall not exceeds by 5.0% of the maximum total loss values. 286 The combination of CSS shall be as per details below:- 287 (a) Supply of 3 way 11kV ,3Phase, 50Hz, 3 wire , earthed neutral, Indoor type floor mounted, non extensible, having hinged arc proof cable doors, breaking capacity 18.4 kA,VCB Ring Main Unit enclosed in robotically laser welded stainless steel tank having IP67 degree of protection consisting of following:- 288 (i) 1 Nos. 630Amps Fault making load breaking spring assisted SF6 Ring Switches, fitted with fixed type voltage indicator device as per IEC 61958 along with associated sensor and fault passage indicator.(ii) 2 No. 630Amps tee off spring assisted type vacuum circuit breaker unit with self powered series trip microprocessor based numericalover current and Earth faultrelay for protection, fitted with fixed type voltage indicator device as per IEC 61958, along with associated sensor and fault passage indicator and ring core type protection Current transformer along with LV compartment with Ammeter with selector switches.(iii)Air Insulated Metering panel connected along with above unit , 18.4 kA , 630 amps, having Potential transformer,connected jumpers / Bus Bar, LV Compartment to incorporate Votmeter andEnergy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI as per the requirement (at incoming VCB) (Please refer SLD). 289 (b)1 No. 11 KV/415 V, 630 KVA three phase (with %Z is 4.5%) , 50 HZ, DYn11, +10% to -10%in 2.5% equal steps ON LOADTAP CHANGER (OLTC), oil cooled, outdoor mounting type, hermitically sealed, corrugated wall design low loss transformer with Cu winding and standard fittings.(minimum 240 Sq MM HT (E) XLPE AL cable are used for the connectivity between transformer &HT Breaker) 290 LT Bus Bars : 1000 AMP,500 Volts, 3 phase 50 HZTPN. The current density of bus bar shall not exceed1.0 sqmm / Amp 291 Neutral Bus : - Separate 2 nos 32 x 6 mm Copper insulated strip (with conductivity mim 99%) directly connected from neutral point of transformer. 292 (c )Incoming cum Outgoing - 415 VoltL.T. breaker Panel having 1000 Amp FP ACB, 50 kA fixed type, with microprocessor based O/L, E/F, S/C, Inst. S/C releases with CT/PT, ammeter with ASS, Voltmeter with VSS, PF meter, Hz meter, energy enalyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI,phase indicating lamps, On/Offf/Trip indication. 630 KVA Compact Sub Station. 293 DIESEL GENERATING SET 294 Supply, Installation, testing and Commissioning ofSilent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization / PLC based load manager, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following. 295 Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system. 296 Instrument Panel - Engine mounted Instrument Panel fitted withand having digital display for followings : 297 Start stop switch with keyWater temperature indicationLubrication oil pressure indication.Lubrication oil temperature indication.Battery charging indicationRPM indicationOver speed indicationLow Lube oil trip indicationEngine hours indication 298 Alternator- Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required. 299 Note : - Alternator should have with all other accessories as per specified in Technical specfications. 300 Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.Inbuilt Fuel tank ofstandard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.Daily service Fuel tank of990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system,level indicators and all standard accessories etc. as required.Exhaust Silencer - Exhaust manifold with residential silencer.The D G set should be supplied with required hardware for external PLC based auto load management system.Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications. 301 550 KVA 302 Supply, Fixing, testing and Commissioning of Exhaust gas piping system ofClass `B MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil.The measurement shall be doneon the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will gowell above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will beconfirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval): 300 mm dia (wall thickness - 4.85 mm) (for 625 KVA DG sets) 303 Supply & fixing of SSBellow of following diameter : 300 mm dia(for 500 KVA DG sets) 304 Supply & fabrication ofD G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MSangle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation. 305 FUEL PIPING 306 Providing and fixing in position the following MSpipes classC (As per IS : 1239) cut to required lenghts and installed with screwed joints including providing and fixing in position the necessary fittings like elbows, tees and reducers, sockets, MS supports and accessories including digging and refilling earth where required for buried pipes / suspended from ceiling including pipe hanger / clamped from wall including hardware complete as per site requirement.: 25 mm NB MS pipes (IS: 1239, 4.0 mm thick) 307 Providing & fixing of hand lever operated forged brass body full way ball valve type isolating valve having forged brass hard chrome plated mirror finish ball, steel handle with PVC grip, teflon seat, screwed ends tested to a pressure of 10 kg/sqcm suitable for HSD complete.:25 mm nominal bore 308 Supply, installation, testing and commissioning of Fuel Level sensor (for Low & high level) 309 MAIN LT PANEL & SUB DISTRIBUTION PANELS 310 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings,instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete withsuitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. 311 INCOMING-800 Amp. MCCB-1 Nos.OUTGOINGS -1 nos. 200 AMPS TP MCCB. (25 KA)2 no. 100 AMPS TP MCCB. (25 KA)2 nos. 63 AMPS TP MCCB. (25 KA)1 nos. 200 AMPS TP MCCB. (25 KA) (for spare)1 nos. 100 AMPS TP MCCB. (25 KA) (for spare)1 nos. 63 AMPS TP MCCB. (25 KA) (for spare) 312 AUTOMATIC POWER FACTOR CORRECTION PANEL(CAPACITOR PANEL) 313 Supply, Installation, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 200 KVAR A P F C Panel consisting of 5 / 10 / 15 / 20 / 25 / 50 KVAR at 415 Volts (rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust &vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623All outgoings MCCBs shall be thermal-magnetic based with inbuilt O/L & S/C release.All MCCBs shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified is Ics value. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CTs, PTs, etc 314 Capacitor duty contactors should be used for switching individual capacitor banks.The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec.Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose.The capacitor panel shall be integrated with the main L T Panel as per schematic diagram 315 INCOMINGIncomer circuit breaker has been included in the main panel.1 set- 3 CTs , ratio 600/5A Class 1.0 accuracy 15 VA burden formetering.1Nos- (0-600A) digital Ammeter with selector switchMicro processor based automatic power factor control relay (3phase) (including power factor meter) in 9 steps for automaticcut off or add on capacitor units to keep the power factor at0.95 with variation of loads. All associated auxiliary contactors /relays shall be provided with in the scope of work.Phase indicating lamps with HRC fuses, and indicating in eachcapacitor chamber unit to indicate On/Off status of capacitorunit.BUS BARS600 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivityelectrolytic Aluminium bus bar with conductivity on min 57 to58% of suitable length, SMC / DMC supports, with colourcoding and insulated by heat shrinkable sleeves and clips onshrouds for joints. The current density of bus bar shall beminimum 1.0 sq mm / amp.The Maximum allowable temperature for the Bus bar to berestricted to 85 deg C. The temperature rise should berestricted to 35 deg C above ambient temperature. 316 OUTGOINGS -2 nos. of 125 AMPS TPN 25 KA MCCB and 150 amps AC3 dutycontactor with 50 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.2 nos. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 dutycontactor with 25 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 dutycontactor with 20 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 40 AMPS TPN 25 KA MCCB and 50 amps AC3 dutycontactor with 15 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 32 AMPS TPN 25 KA MCCB and 40 amps AC3 dutycontactor with 10 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 16 AMPS TPN 25 KA MCCB and 20 amps AC3 dutycontactor with 5 KVAR heavy duty MPP type at 415 V capacitorbank (rated Voltage 440 Volts) , auto-manual selector switch,start stop push button for manual operation including on/offindicating lamps and delay timer complete.1 SET 200 KVAR CAPACITOR PANEL 317 Electrical Panel-1 (Block-1)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamberetc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 8 nos.40 AMP MCCB 8 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 318 Electrical Panel-2 (Block-2)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving andmounted on non hygroscopic supports such as CMC/BMCsupport withdeteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.INCOMING-200 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 5 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 319 Electrical Panel-3 (Block-3)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and otherparameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 813 (E)INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 8 nos.40 AMP MCCB 8 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 320 Electrical Panel-4 (Block-4)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/ 812 (C)INCOMING-200 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 6 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 321 Electrical Panel-5 (Block-5)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/813(E)INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 6 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 322 Lighting Panel for Basement :Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 / 811 (C)INCOMING-100 Amp. MCCB-1 Nos.OUTGOINGS -63 AMP MCCB 2 nos.40 AMP MCCB 5 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 323 UPS O/G Panel:Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as perIS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/811 (C)INCOMING-100 Amp. MCCB-1 Nos.OUTGOINGS -63 AMP MCCB 2 nos.40 AMP MCCB 2 nos.40 AMP MCCB 18 no.25 AMP MCCB 18 no.40 AMP MCCB 1 no. (spare)25 AMP MCCB 1 no. (spare) 324 CO2 Gas Flooding System For Main LT PanelSupply, installation, testing and commissioning of Polymer Tube Detection based CO2 Gas Flooding System For Main LT Panel, Consisting of the following components: CO2 Cylinder, 4.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility). 325 CO2 Cylinder, 2.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility). 326 Filling adopter 327 D/I Adopter for converting the indirect valve to function as Direct System. 328 FET End of Line adapter with Pressure gauge for Automatic fireuppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Fitting made by brass (plated / unplated), Stainless steel, Elastomeric Sealings, Copper Nickle plated, Temperature range TS -20 Deg C till + 60 Deg C, Maximum working pressure 25 Bars, made as per PED Pressure Equipment Directives. 329 Pressure Switch to monitor Pressure drop in the tube, switchpoint 11 Bars. 330 Flexible Polymer Detection Tube made by special modified Polyamide (PA), Color Red, High grade quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM, Melting Point approx. 220 degrees Celsius when heating up with 10 K/minute, Steady load tested upto max. 80° C. The lowest operating temperature is stipulated at minus 40°C. Service Pressure 20 Bar, Burst Pressure at 20 Deg C approx 120 Bars, Release Temperature : Rapid heat increase in temperature at 20 bars pressure approx 150 Deg to 180 Deg C (Without Flame) 331 Master Control Unit for connecting each system with electronic hooters and productivity input to Scada /Fire Alarm system including all necessaries +electrical wiring to make each entire system functional.(Indeginous) 332 Containing all required fitting and fixing 333 Installation & Commissioning Charges includes complete setup of the system, Installation of Cylinders on specially designed brackets, Laying of sensor tubes using tube attachments and Cable ties, fixing end of line plugs and end of line adapters, pressurizing tube @ 15-18 Bars using Nitrogen pressurizingagent. 334 Supplying and fixing and connection of the following rating, four Pole MCCB (25 KA), 415 volts, at the incomer / outgoing in seperate enclosure, complete with connections, testing and commissioning etc. as required : 100 AMP FP MCCB (25 KA) micro processor based. 335 (VI) INVERTORSupply, installation, testing and commissioning of on lineUPS with builtin parallal redundancy, as per following detailsTechnology : Micro processor based controls, True on line,Double conversion type, should have cold start facility.Input :- (mains / local D G set compatibility)a) Voltage : 415 V / 3 Phaseb) Voltage Variation : - 20% to + 20%c) Input Frequency : 50 Hz.d) Frequency Variation : + 10%e) Automatic phase sequence correction facilityOutput :-a) Voltage : 230 V / 1 Phase, 415 V / 3 Phaseb) Voltage Variation : + 1%c) Frequency Variation : 50 Hz. + 0.1%Overall Efficiency : > 90%Charger : Should have built in charger to suit systemrequirement.Battery type : Sealed Maintenance Free - SMF (Global Yuasa /Exide)Battery Backup = 15 min.External battery backup will be usedDisplay : Should have LCD display with event logging facility.Upgradeability : Should be upgradeable to work as parallelredundant UPS in load sharing mode.Software Communication : Should have SNMP (Simple NetworkManagement Protocol) compatibilityRating : 30 KVA 336 SUB-HEAD - 1 : S/F MODULAR TYPE SWITCH / SOCKET & SUBMAINS 337 Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required.DSR 1.57 338 Wiring for circuit/ submain wiring along with earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. DSR 1.14 339 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (DSR 1.14.4) 340 2 X 16 sq. mm + 1 X 6 sq. mm earth wire(DSR 1.14.6) 341 4 X 6 sq. mm + 2 X 6 sq. mm earth wire(DSR 1.14.9) 342 4 X 10 sq. mm + 2X6 sq. mm earth wire(DSR 1.14.10) 343 SUB-HEAD - 2 : DISTRIBUTION BOARDS & CIRCUIT BREAKERS 344 S/F of surface / flush mounting SPN Distribution board with additional metal door without MCB complete in all respects as directed at site by Engineer-in-charge. a) 12 WAYS CAT A (UPSOR 1025(A) 345 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. (a) 4 WAYS CAT A (UPSOR 1026 (A) 346 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. 6 WAYS : CAT A (UPSOR 1027(A) 347 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. : 8 WAYS: CAT A (UPSOR UPSOR 1028(A) 348 Supply & fixing of 6/10/16/20/25/32 amp. SP MCB (10 KA) : CAT A(UPSOR 1002 349 Supply & fixing of 63 Amp DP MCB (10 KA) :CAT A : UPSOR 1011 350 S/F of 63 amp FP MCB (10 K.A.) :CAT A : UPSOR 1020 (A) 351 S&F and making connection of 63A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.UPSOR 394 352 S&F and making connection of 63 Amp. 4 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. UPSOR 398 353 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. UPSOR 1109 354 S&F single pole MCB blanking plate UPSOR 1034(B) 355 SUPPLY AND LAYING OF CABLES & ACCESSORIES 356 Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor byclamps etc UPSOR (501) 357 6 sqmm 3 core 358 10 sqmm 4 core 359 16 sqmm 4 core 360 25 sqmm 3 1/2 core 361 35 sqmm 3 1/2 core 362 50 sqmm 3 1/2 core 363 95 sqmm 3 1/2 core 364 120 sqmm 3 1/2 core 365 150 sqmm 3 1/2 core 366 185 sqmm 3 1/2 core 367 240 sqmm 3 1/2 core 368 300 sqmm 3 1/2 core 369 deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required. 370 Supply fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge (UP SOR 504) 371 6 sqmm 372 10 sqmm 373 16 sqmm 374 25 sqmm 375 35 sqmm 376 50 sqmm 377 70 sqmm 378 95 sqmm 379 120 sqmm 380 150 sqmm 381 185 sqmm 382 240 sqmm 383 300 sqmm 384 Supply and fixing brass nickle plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor UPSOR 503 385 6 sqmm 3 core 386 10 sqmm 4 core 387 16 sqmm 4 core 388 25 sqmm 3 1/2 core 389 35 sqmm 3 1/2 core 390 50 sqmm 3 1/2 core 391 95 sqmm 3 1/2 core 392 120 sqmm 3 1/2 core 393 150 sqmm 3 1/2 core 394 185 sqmm 3 1/2 core 395 240 sqmm 3 1/2 core 396 300 sqmm 3 1/2 core 397 Supply of ISI marked Copper conductor PVC insulated cable as per IS 1554 armoured, served, sheathed 1100 volts grade. : 25 sqmm 1 core 398 Laying and testing of aluminium / copper conductor cable PVC / XLPE insulated armoured, served, sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray or inside existing RCC / HDPE DWC pipe complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) / end terminations to the cable leads, insulating with tape and making connections with brass / nickle plated flame proof double compression glands, providing cable tags complete in all respect upto the satisfaction of Engineer-incharge. (The supply of terminations and glands shall be under seperate item): (a) 25 sqmm 1 core 399 Supply and laying of ISI marked Copper conductor PVC insulated control cable as per IS 1554 PVC sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections complete in all respect including end termination, double compression glands, supply of clamps, lugs, tape etc complete upto the satisfaction of Engineer-incharge. Armoured 400 6 x 2.5 sq mm armoured (DG to Main LT panel interfacing) 401 12 x 2.5 sq mm armoured (2 runs DG controlling) 402 12 x 2.5 sq mm armoured ( For Transformer contro wiring) 403 2 x 4 sq mm armoured (for Battery charging) 404 Supply of 3 core stranded aluminium conductor 11 KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments) a) 240 sq. mm 3 core 405 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of following size in the existing masonry open duct etc. as required.a) Size exceeding 120 sq. mm. But not exceeding 400 sq. mm. 406 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core 407 Supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories includinglugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core 408 CABLE TRAY 409 Supply and erection of Perforated type cable trays made out of prefabricated Galvanized sheet steel including tees, bends, crossings, reducers, couplings to be laid in cable trenches or installed over head on wall or hanged from ceiling including all neccessary supports, brackets at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts & bolts complete in all respects.: The support for 1000mm, 900 mm and 750 mm wide cable tray will be by 50 x 50 x 6 mm MS angle, for 600mm and 450 mm wide cable tray will be by 40 x 40 x 5 mm MS angle, for 300mmwide cable tray will be by 32 x 32 x 5 mm MS angle, for 150mmwide cable tray will be by 25 x 25 x 4 mm MS angle. 410 900 mm (W) X 50 mm (H) X 2 mm (T) 411 750 mm (W) X 50 mm (H) X 2 mm (T) 412 600 mm (W) X 50 mm (H) X 2 mm (T) 413 450 mm (W) X 50 mm (H) X 2 mm (T) 414 300 mm (W) X 35 mm (H) X 1.5 mm (T) 415 150 mm (W) X 35 mm (H) X 1.5 mm (T) 416 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 417 90 mm dia (OD-90 mm & ID-76 mm nominal) (DSR 14.16.2) 418 160 mm dia (OD-160 mm & ID-135 mm nominal) DSR 14.16.4) 419 MISCELLANEOUS ITEMS EXTERNAL ELECTRICAL 420 Providing and fixing M.V. danger notice plate of 200 mm x 150 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.21) 421 Providing and fixing H.V. danger notice plate of 250 mm x 200 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.22 422 S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M) UPSOR 1134 423 Supply and fixing of Fist aid box as approved by Indian red cross conforming to IS : 2217. 424 Supply of rubber gloves of 11 KV grade as per IS : 4770. 425 Supply and fixing of cable route maker as directed by Engg-incharge. UPSOR 505 426 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality. to withstand 30 KV dielectric strength as per IS 15652 complete in all respects. (For LT Panels) UPSOR 1136 427 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality to withstand 45 KV dielectric strength as per IS 15652 complete in all respects. (For 11 KV Panels) UPSOR 1136 428 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.a) 300 mm dia. DSR 14.14.4 429 Supply and erection of pregalvanized Ladder type cable trays made out 25mm x 75mm x 25mm x 2.5mm GI Section all along (as runner) and 20mm x 30mm x 20mm x 2.5 mm GI Section (as rungs) at every 250mm interval c/c including tees, bends, crossings, reducers, couplings to be laid over head on wall or hanged from ceiling including all neccessary supports, brackets (50x50x6 MS Angle) at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts &bolts complete in all respects. 430 900 mm (W) X 75 mm (H) 431 750 mm (W) X 75 mm (H) 432 EARTHING 433 BODY / SAFETY EARTHING (FOR BODY OF ALL ELECTRICAL EQUIPMENTS LIKE RISING MAINS, TRANSFORMER, DG SETS,LIFTS ETC. 434 Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling.The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound. (borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6 mm. Further GI strips from equipments shall be connected to Copper strips by means of special bi-matellic connector (i.e. stainless steel). please refer submitted drawing. 435 Providing & fixing 25mm x 5mm G.I. strip on surface, in recess or in ground including connections etc. as required (LT Panel,Cable Trays & Elevator). DSR 5.15 436 Providing & fixing 32mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (Pig tail) UPSOR 717 437 Providing & fixing 50mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (SubstationGrid) 438 NEUTRAL EARTHING 439 Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling.The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound.(borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6mm. please refer submitted drawing. 440 Providing & fixing 32mm x 6mm insulated Copper strip on surface, in recess or in ground including connections etc. asrequired. 441 SOLAR PLANT 442 ON-Line Solar Photovoltaic system plant including suitable rating Poly crystalline Silicon PV Modules having a efficiency of minimum 15% (without any power export arrangement), String combiner box, DC Distribution board etc. complete as required. Scope of work also includes supply, installation of GI structure, (80 micron) in suitable section complete with all accessories and hardware including civil work as required at site for mounting PV panels.: 15 kWp SET 170 415 V, 3 phase, 50 Hz AC power string inverter (Grid intractive) with stand & all protection and controls having overall efficeiency of not less than 95%. : 15 kWp (nominal) SET 171 AC distribution board made of 2 mm CRCA sheet, power coated having IP55 degree of protection (for indoor installation) for terminating 415 V, 3 phase, 50 Hz power suppled from inverter complete height with following multifunction: - Digital multifunction meter (EM 6400 of Schnieder or equal) - 40 Amp TPN MCB (10 KA) - Phase indicating lamps. SET 1Lighting Arrestor SET 1Surge Protector SET 1 443 STREET / EXTERNAL LIGHTING 444 Supply & fixing of 20 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 410 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect.(UPSOR 653) 445 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect.Category AAA (UPSOR 1455) 446 Supply and fixingof LED Street light Fitting having die cast aluminium body and diffuserwith driver set suitable for 45 watt to 50 Watt. Confirmingto IP 65 and above protectioncomplete in all respect.Category AAA (UPSOR 1443) 447 Supply and fixingof 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminiumbody with drive set . Confirming to IP 65 and above Protection complete in all respect.Category AAA (UPSOR) MR 448 Supply and fixingof 3 Watt to 4 Watt LED Spot/Spike light Confirming to IP 65 and above Protection complete in all respect. Category AAA (UPSOR 1441) 449 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 and above protection complete in all respect.Category AAA 450 Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation,excavation & back filling and Required T&P completee in all respect. 451 Supply installation, testing and commissioning of 3x2.5 sqmm flexible fire retardant copper connecting wire of required length from MCB in cable junction box of pole to luminaire along with MCB & Connector complete as required. 452 Supply & burrying of 40 mm dia x 4.50 m long G.I. pipe vertically for earthing having 12 mm dia holes spaced 75 mm apart drilled upto 2 meter brom the bottom complete with one earthing lead of no. 6 to 8 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switchboard (from apron to switch board the cost of GI pipe & GI wire will be extra), 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect. 453 Supply & burrying of 600mm x 600 mm x 6.0 mm G.I. plate, vertically for pole earthing with its top at least 3 m below ground level complete 20mm dia. G. I. pipe and funnel for watering and one earthing lead of no. 8 to 10 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switch board (from apron to switch board the cost of GI pipe & GI wire will be extra) 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . 454 Supplying & Laying of one number 8 SWG G. I. wire in 15 mm. dia. G. I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P and other material required for proper completion of the work as directed at site. 455 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 456 INCOMER : 457 f (ii) 40 AMP TPN MCB (10 KA) 458 e (ii) 25 AMP TPN MCB (10 KA) 459 OUT GOINGS : 460 4 nos. 6-32 AMP DP MCB (10 KA) 461 24 nos. 6-32 AMP DP MCB (10 KA) 462 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. 10 sqmm 3 core 463 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Size not exceeding 35 sq. mm. 464 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. Size not exceeding 35 sq. mm. 465 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe etc. as required. Size not exceeding 35 sq. mm. 466 Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. e) 6 sqmm 3 core 467 Deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
38.
Housing Urban and Rular Development #9463349 Technical Bid
Tender For Tourism Development Of Gaura Baba Mandir At District Banda (U.P.), 1 Tourism Development of Gaura Baba Mandir at District Banda (U.P.) 2 MULTIPURPOSE HALL 3 Excavation infoundation inordinary Soil ( Loam clay or sand ) including lift upto 1.5m lead upto 30.0 m& including filling wateringand rammingof excavated earth into the space between the building & sides offoundation trenches or into the plinth and removal& disposal surplus earthas directed by the engineer I/C within a lead of 30 m.from foundation trenches. 4 Filling of carted earth . 5 Sand filling in plinth including supply of necessary quantity of local sand from a distance not exceeding 8 km from the site of work and including watering dressing etc, required for proper completion of work. 6 Providing and laying Cement concrete 1:4:8 (1cement :4 coarse sand :8graded stone ballast 40 mm. nominal size) including supply of all materials, labour and T&P etc. required for proper completion of the work and curing complete, also including cost of formwork in foundation. 7 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturers standard dilution) 8 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 9 Concrete of M25 grade with minimum cement content of 330 kg /cum 10 Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 300 mm dia piles 11 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Group of two or more piles upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity) 12 Routine test (Test Load 1.5 times the Safe capacity) 13 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 14 Class-150 brick work in 1:6 cementand Coarse sandmortar in foundation and plinth including supply of all materials, labour tools and plants, etc. Required for proper completetion of the work. 15 Same as in item no. 10 abovebutin super-structure above plinth level up to floor two level (up to two storeys) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand). 16 15 mm cement plaster on plinth of mix : 1:4 (1 cement: 4 coarsesand). 17 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand .F.M. 2.25 18 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. 19 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 20 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 21 Finishing walls with Textured exterior paint @ 3.28 Ltr. per 10Sqm of approved brand and manufacture and of required shade on undacorated wall surface to give evenshade over including curing and cost of all material, labour, T&P etc. required for proper completion of work.for two coat.over one coat of primer applied 2.20Ltr 10 Sqm. 22 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 23 Kota stone slabs 20 mm thick in risers of steps,skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 24 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-lll) : 4 graded stone aggregate 6 mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand)etc. complete, excluding plastering of the jambs, sills and soffits.50 mm thick 25 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m² 26 Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m² 27 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 28 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 29 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing.40mm thick 30 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 31 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 32 Providing and fixing horizontal chajja of stone 40 mm thick and upto 80 cm projection in cement mortar 1:4 (1 cement : 4 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :Red sand stone 33 Stone work plain ashlar in arches in super structure upto floor V level in cement mortar 1:3 (1 cement : 3 coarse sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 34 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 35 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concree 36 Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 37 Columns, Pillars, Piers, Abutments, Posts and Struts 38 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C 39 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 40 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 41 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 42 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire 43 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 44 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 45 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 46 Supply of surface mounting 2x2 feet 36W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 47 Supplying, erection, connecting, testing and commissioning of 600 mm Wall Fancomplete in all respect. 48 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 63 A,25KA,FP MCCB 49 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way Double door 50 8 way Double door 51 Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.)4 way (4 + 12), Double door 52 Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps TP MCB 53 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. As required. 25 amps 54 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 55 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 56 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 57 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 58 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 59 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 60 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 61 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm. 62 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm. 63 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle 64 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 16 sq.mm 65 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.4 X 16 sq. mm (28mm) 66 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia 67 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 68 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness. 69 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness. 70 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) 71 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. Single Push Fit Coupler 110 mm dia 72 Single tee with door 110x110x110 mm 73 Plain bend 87.5 deg 110 mm dia 74 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia 75 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 76 PLATFORM 77 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.Language as per DSR 78 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 79 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 80 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 81 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 82 Concrete of M25 grade with minimum cement content of 330 kg /cum 83 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 84 Lintels, beams, plinth beams, girders, bressumers andcantilevers 85 Columns, Pillars, Piers, Abutments, Posts and Struts 86 Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 300 mm dia piles 87 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 88 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. 89 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. 90 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick 91 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing .40 mm thick 92 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 93 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 94 TOURIST SHELTER (02 No.) 95 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 96 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 97 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 98 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos E.C. 20% with 1% concentration 99 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration 100 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 101 Concrete of M25 grade with minimum cement content of 330 kg /cum 102 Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 300 mm dia piles 103 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Group of two or more piles upto 50 tonne Safe capacity 104 Routine test (Test Load 1.5 times the Safe capacity) 105 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for massconcrete 106 Suspended floors, roofs, landings, balconies and accessplatform 107 Lintels, beams, plinth beams, girders, bressumers andcantilevers 108 Columns, Pillars, Piers, Abutments, Posts and Struts 109 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 110 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) 111 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 112 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 113 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more 114 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. 115 15mm thick plaster with cement mortar in proportion of 1:6 cement & coarse sand of 2.25 F.M. (1) 1 cement : 6 coarse sand Ground Floor 116 12mm thick plaster with cement mortar in proportion of 1:6 cement & coarse sand of 2.25 F.M. (1) 1 cement : 6 coarse sand Ground Floor 117 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 118 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 119 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer 120 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 121 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 122 Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand (zone-lll) : 4 graded stone aggregate 6 mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 40 mm thick 123 Providing, hoisting and fixing above plinth level up to floor five levelprecast reinforced cement concrete in mouldings as in cornices, windows sills etc, including setting in cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Red sand stone 124 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll)erived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 125 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C 126 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 127 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 128 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 129 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 130 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 131 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 132 Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) 133 Supply ofSurface mounting round 12 Watt 15 Watt ,suitable for 24Hr Continuous Operation, 100lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect 134 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan 135 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double Door 136 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 137 Double pole 138 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 139 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 140 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 141 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 142 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 143 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 144 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm. 145 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle 146 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment4 x 16 sq.mm 147 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.4 X 16 sq. mm (28mm) 148 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required 100 mm dia 149 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 150 PUBLIC SANITATION BLOCK 151 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 152 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 153 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 154 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 155 Concrete of M25 grade with minimum cement content of 330 kg /cum 156 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 157 Suspended floors, roofs, landings, balconies and access platform 158 Lintels, beams, plinth beams, girders, bressumers and cantilevers 159 Columns, Pillars, Piers, Abutments, Posts and Struts 160 Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 300 mm dia piles 161 Brick Work with common burnt clay ( non modular) bricks of class - 150 in foundation and plinth in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) 162 Brick Work with common burnt clay ( non modular) bricks of class - 150 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 ( 1 cement : 6 coarse sand) G.F. 163 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class - 150 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) G.F. 164 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 165 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 166 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 167 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :. 250mm x 16mm . 168 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250mm x 10mm . 169 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150mm x 10mm . 170 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm 171 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm 172 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 173 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 174 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes 175 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 176 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 177 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 178 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) 179 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 180 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 181 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) 182 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 183 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 184 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 185 Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water abDSRption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. With out base concreteGlazed Vitrified tiles Matt/Antiskid finish of 600X600mm size. 186 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment tomatch the shade of the slabs, including rubbing and polishing complete. 187 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 188 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 189 Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work. 190 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 191 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture 192 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing .40mm thick 193 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 194 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 195 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 196 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 197 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 198 Providing & fixing toilet paper holderC.P. brass 199 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 200 Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. 201 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap 202 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 203 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 204 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 205 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 206 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 15 mm nominal bore 207 Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore 208 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore 209 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore 210 Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. 211 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) 212 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth. Granite Stone of approved shade 213 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. For Internal Toilet15 mm nominal outer dia Pipes 214 20 mm nominal outer dia Pipes 215 25 mm nominal outer dia Pipes 216 32 mm nominal outer dia Pipes 217 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal bore 218 32 mm nominal bore 219 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall Terrace loop & Tank Filling Pipe 25 mm nominal bore 220 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 25mm diameter pipe 221 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25mm diameter pipe 222 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : For vertical pipe connection with terrace ringmain 25mm nominal bore 223 32mm nominal bore 224 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore 225 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 25 mm nominal bore, 152 mm long, weighing not less than 440 gms 226 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 227 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) 228 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. Single Push Fit Coupler 110 mm dia 229 Single tee with door 110x110x110 mm 230 Plain bend 87.5 deg 110 mm dia 231 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia 232 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 233 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes. Internal Toilet (Soil & Waste Pipe) 75 mm 234 110 mm 235 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (45°) 75mm 236 110mm 237 Bend without door (87.5°) 75mm bend 238 110mm 239 Y Fitting without door 75mm 240 110mm 241 Single Tee without door 75mm 242 110 mm 243 Single Tee with door 75mm 244 110 mm 245 Bend with door (87.5°) 75mm 246 110 mm 247 Clean Out Plug (COP) 75mm 248 110 mm 249 Reduced Y Fitting without door 110mm x 75mm 250 Coupler 75mm 251 110mm 252 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc.For Wash basin & Urinal 32mm dia. Pipe 253 50mm dia. pipe 254 Elbow (45°) 32mm 255 50mm 256 Elbow (90°) 32mm 257 50mm 258 T fitting 32mm 259 50mm 260 Coupler32mm 261 50mm 262 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 110mm x 75mm x 50mm/40mm (Toilet) 263 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 110mm x 75mm (Toilet & Kitchen) 264 Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 265 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter 267 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 268 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 100mm dia SWpipe 269 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C 270 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 271 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 272 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 273 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 274 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 275 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 276 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep 277 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 278 Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 279 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required. 300mm EXHAUST FAN 280 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Way Double Door 281 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 282 Double pole 283 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 284 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 285 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 286 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 287 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm. 288 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm. 289 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle 290 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment3 x 6 sq.mm, 291 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 2 X 6 sq. mm (19mm) 292 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 293 GHAT 294 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 295 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 stone ballast 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 296 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extracement Concrete of M25 grade with minimum cement content of 330 kg /cum 297 Concrete of M25 grade with minimum cement content of 330 kg /cum 298 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 299 Suspended floors, roofs, landings, balconies and access platform 300 Lintels, beams, plinth beams, girders, bressumers and cantilevers 301 Columns, Pillars, Piers, Abutments, Posts and Struts 302 Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) :450 mm dia piles 303 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor pilesmethod and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Group of two or more piles upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity) 304 Routine test (Test Load 1.5 times the Safe capacity) 305 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 306 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 307 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone flooring 308 Supplying and filling of boulder pitching including wire & necessary lead & lift including transportation etc. All complete in direction of engineer in charge. 309 Making coffer dam with laying or empty gunny bags including filling of sandy / local soil and placing in two parallel lines with proper gap in river to retain the water for construction of work including filling of sandy soil aforesaid gap of two paralle gunny bags line and laying a layer of soil over each layer of bags including cost of material , labour , t & p required for propercompletion of work 310 Making barricading with burrying of M.S. pipe 750 mm c/c horizontal distance by means of pressure method in river bed to hold the coffer dam due to 5-7 meter depth of river including fixing of pipe horizontal & cross to strengthen placing bamboo mat and polythene sheet protected with pvc tarpoline both along side barricading as per direction of Engineer in charge including cost of material , labour , t & p required for propercompletion of work 311 Pump out water caused by springs , tidal or river seepage , broken water mains or drains and the like. 312 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone flooring 313 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing .40 mm thick 314 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 315 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 316 DRAIN COVER 317 Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100 mm c/c on both ways, neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over priming coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc including cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. 318 INTERLOCKING 319 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil (D.S.R. 2.8.1) 320 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) (D.S.R. 4.1.8) 321 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 322 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 323 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 324 SEPTIC TANK & EXTERNAL 325 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. up to 1.50 m depth Pipes 80 mm to 300 mmdiameter 326 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter 327 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.150 mm.dia. RCCPipes 328 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm.dia. RCCPipes 329 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 330 Extra for depth for manholes:Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 331 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 332 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 40mm nominal bore. 333 32mm nominal bore. 334 25mm nominal bore. 335 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40mm nominal bore. 336 25mm nominal bore. 337 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 338 SEPTIC TANK & SOAK PIT 339 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width aswell as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5 m, as directed by Engineer-incharge. In all kind of soil upto 1.5m depth 340 In all kind of soil upto 1.5m to 3.0m. depth 341 In all kind of soil upto 3.0m to 4.5m. depth 342 Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 40mm nominal size) 343 Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) 344 Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) excluding centering and shuttering and reinforcement. 345 Suspended floors, roofs, landings, balconies and access platform. 346 P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. 347 12mm cement plaster on rough side of mix 1:3 (1 cement : 3 coarse sand) 348 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 349 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 350 Providing & fixing 75mm dia vent pipes. 351 Providing & fixing of 75mm dia cast iron terminal guard. 352 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter 353 M.D. -2.5- Circular shape 450mm internal diameter 354 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks 355 SUBMERSIBLE 356 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre below ground level. 300 mm dia 357 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accesDSRies etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 358 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accesDSRies etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm Nominal Size dia 359 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 360 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compresDSR, running the compresDSR for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compresDSR, tools & accesDSRies etc., all as per requirement and direction of Engineer-in-charge. 361 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm Dia 362 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp 363 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm Dia 364 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm nominal size dia 365 Electric logging of bore hole 366 Supply and Installation of 1.5 HP Submersible pump set complete 367 LANDSCAPE & HORTICULTURE 368 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 369 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 370 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm 371 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 372 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 373 Rough dressing the trenched ground including breaking the clods. 374 Fine dressing the ground 375 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately). 376 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 377 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge With grass Turf 378 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 379 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep 380 Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 381 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) 382 Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 383 Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 384 Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 385 Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. 386 Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge 387 Supply and stacking of Plumeria alba plant of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge. 388 Supply and stacking of Plumeria rubra plant of height 120-150 cm. with 3- 4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge 389 Supply and stacking of Tabebuia sp. plant of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 390 Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge 391 Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 392 Supply and stacking of Michelia champa (Golden Champa)plant of height 90-105 cm. in earthen pots of size 25 cm as per direction of the officer-incharge. 393 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 394 TOURIST FACILITIES 395 Resting Areas for Tourist (Benches) {MR} Providing & fixing ofred Sandstone/MS bench with Ornamentetion (size 1500mm length and 450mm and height 600 mm) including foundation & support with all necessary T&P etc all complete as per design of direction in engineer/ Architect in charge. 396 Urban Litter Bins(MR) Providing & fixing of SS Dustbin size 487 x 399 x 1138 fixing on a foundation with base plate and wrapped with red sandstone from all sides of 75mm with all complete as per design of direction in engineer/ Architect in charge. 397 Directional & Informative Signages (MR) Providing and fixing StandAlone Signage in Marble of approved thickness with powder coated 10-12mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in charge English: Helvetica Font with min. 36 sizeHindi: Krutidev Fontwith min. 36 size Signage-A 398 Signage-C 399 Receiving, storing, handling, shifting, installation, testing & commissioning ofVoltas water cooler, including all accessories complete in all respect etc. (Make - Voltas or Equivalent) 400 LIGHTING & EXTERNAL ELECTRIFICATION WORK 401 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCBs (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. an d insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. MAIN PANEL Panel described as above 402 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each. 403 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 404 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 405 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 406 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 407 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm. 408 Above 35 sq.mm. and up to 95 sq.mm. 409 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm. 410 Above 35 sq.mm. and up to 95 sq.mm. 411 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle 412 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp 413 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment3.5 x 70 sq.mm 414 3 x 6 sq.mm, 415 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 2 X 6 sq. mm (19mm) 416 3½ X 70 sq. mm (38mm) 417 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100mm dia 418 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 419 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 420 POLE LIGHTS Supply ,Installation ,Testing And Commissining OfTwinkle Lites Make 3000Mm Long Hybrid Decorative Pole With CastedAluminium Base And Ripped Gi Pole PipeWith Decorative Post Top Lantern Concord 1270Mm Long With Polycarbonate Diffuser In 60W Led Having Lumn Output Not Less Than 110Lmns/Watt With 10Kva Surge Prtector Designed As Per Architect In-Charge( Make- Twinkle Lite- /-Havells/Neri/Juvaas/Orient/ Thor) 421 SITC of 15w integrated Solar All in one suitable at height of 5mtr mounting arrangement. pole with minimum 2250 lumen , luminous flux with min.>150lm/w luminous efficacy having power of PV module (Wp) 40, Panel Type Mono Crystalline, Panel Dimensions not more than (mm) 775 (L) x 340 (W) x 60 (H), Battery Capacity max. 18 (Ah), Battery Rated Voltage 12.8(V), Battery type LiFePO4, having BMS protection Battery Management System ,having min. Battery Back up to 2days (24 hours) (Autonomy mode),MPPT charge controller type, Efficacy>90%, having facility of Charging Indicator (Green blinking),Low Battery Indicator (Red blinking),Error Indicator (Both blinking),For the better battery life having Over Charge Protection, Deep Discharge Protection, Battery reverse polarity protection ,Load Short circuit protection, Load Open circuit protection, Reverse polarity protection for Panel, Over temperature protection. Motion sensor detection facility with Long Distance Detection 12m.CCT-5500-6000k, Make-Panasonic, Philips or equivalent 422 Supply, Installation, Testing and Commissioning of LEDRGB/RGBW flood lighting luminaire for facade lighting with Die- cast aluminium housing, powder- coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX/ Ethernet based control. The be amangle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270 VAC, 50Hz with power factor>0.9. Fixture shall be suitable to operate at anambient temperature range of-10°Cto +50° C and shall be IP65 and IK06 rated. Life time shall be atleast L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS(IS10322) and shall be complete with all necessary accessories required for proper working of fixture in cluding weatherproof connection cables, waterproof connector setc. as required. 30 W 423 Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver andapable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 40 W 424 Supply and Fixing of Spike Light for trees 12 watt Warm White. (Including civil works) 425 Supply and fixing of steplight Robust DESIGN IP67/IK10 easy to mount with suitable mounting box BWG 50led50/NWPSU 220-240V IP67 7043(Philips/Panasonic/Havells or Equivalent) 426 Supply and Fixing 24 Wattage Burial UNIIn Ground- Burial ip68 waterproof BBP343 LED2400/1800/WW 24W/18W 20D 100-240V (Philips/Siems/or Equivalent) 427 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 428 Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 1 output per phase and suitable for single phase supply 429 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 metre and upto 8.0 metre 430 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required 32 mm dia 431 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
39.
Housing Urban and Rular Development #9456640 Technical Bid
Tender For Tourists Facilitation Cenre Near Kalinjer Fort Banda, District Banda (U.P.), 1 Tourists Facilitation Cenre Near Kalinjer Fort Banda, District Banda (U.P.) 2 CIVIL WORK 3 Earth work in excavation by mechanical means(Hydraulicexcavator)/manualmeans over areas (exceeding 30cm in depth. 1.5m in widthaswellas10Sqmonplan)including disposal of excavated earth, lead upto 50m and liftupto1.5m,disposedearthtobelevelled and neatly dressed. 4 Fillingavailableexcavated earth(excluding rock)intrenches,plinth,sidesoffoundations etc.inlayersnotexceeding20cmindepth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Excavating, supplying and filling of local earth (including royalty) by mechanical transport uptoaleadof5kmalsoincludingramming and watering of the earth in layers not exceeding20cmintrenches,plinth,sidesof foundation etc. complete. 6 Providing and laying inposition cement concrete of specified grade excluding the cost ofcenteringandshuttering-Allworkupto plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 7 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 8 Treatmentofsoilunderexistingfloorsusing chemicalemulsion@onelitreperhole,300 mmapartincludingdrilling12mmdiameter holes and plugging with cement mortar 1:2 (1 cement:2coarsesand)tomatchtheexisting floor. WithChlorpyriphos/ Linadane E.C. 20% with 1% concentration. 9 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping chargesLintel. Ground Floor 10 First Floor 11 Second Floor 12 Terrace Floor 13 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Slab Ground Floor 14 First Floor 15 Second Floor 16 Terrace Floor 17 Ready mix concrete M 25 = 1.00 cum. i/cplacing of concrete, vibrating, leveling etc5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCCGround Floor Tie Beam 18 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Slab BeamGround Flooor 19 First Floor 20 Second Floor 21 Terrace Floor 22 Ready mix concrete M 25 = 1.00 cum. i/cplacing of concrete, vibrating, leveling etc5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC. Raft Foundation 23 Ready mix concrete M 25 = 1.00 cum. i/cplacing of concrete, vibrating, leveling etc5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC. Column Ground Floor upto plinth level 24 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Column Ground Floor 25 First Floor 26 Second Floor 27 Terrace Floor 28 BrickworkwithcommonburntclayF.P.S. (nonmodular)bricksofclassdesignation7.5 in foundation and plinth in:Cement mortar 1:6(1 cement : 6 coarse sand) 29 Providingandlayingdamp-proofcourse40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 12.5 mm nominal size). 30 Paintingon D.P.C. withtwocoatsof airblown bitumen 85/50 or 85/25 @ 1.7 kg/sqm approx. including cost of fuel if any. 31 BrickworkwithcommonburntclayF.P.S. (nonmodular)bricksofclassdesignation7.5 in superstructure above plinth level up to floor Vlevelinallshapesandsizesin:Cement mortar 1:6 (1 cement : 6 coarse sand) Ground Floor 32 First Floor 33 Second Floor 34 Terrace Floor 35 HalfbrickmasonrywithcommonburntclayF.P.S. (non modular) bricks of class designation7.5 insuperstructureabove plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) Ground Floor 36 First Floor 37 Second Floor 38 Terrace Floor 39 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positionandbindingallcompleteuptoplinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. Ground Floor 40 First Floor 41 Second Floor 42 Terrace Floor 43 15 mm cement plaster on rough side of single orhalfbrickwallofmix:1:4(1cement:4coarse sand). 44 15 mm cement plaster on rough side of single orhalfbrickwallofmix:1:6(1cement:6coarse sand) Ground Floor 45 First Floor 46 Second Floor 47 Terrace Floor 48 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) Ground Floor 49 First Floor 50 Second Floor 51 Terrace Floor 52 ProvidingandlayingMoroccan floortilesin different sizes (thickness to be specified by the lasa brand ) withwater absorptionless than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand), jointing with greycement [email protected]/sqmincludinggroutingthe jointswithwhitecementandmatching pigmentsetc.,complete.SizeofTile300x300 mm Ground Floor 53 First Floor 54 Second Floor 55 Terrace Floor 56 Providing and laying Moroccan tiles in different sizes (thicknessto be specified by manufacturer), with water absorption less than0.08 % and conforming to I.S. 15622, of approvedmake,inallcolours&shade,in skirting,riser of steps,over12mmthick bed of cement mortar1:3 (1 cement:3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement& matching pigments etc. complete.Size of Tile 300x300 mm Ground Floor 57 First Floor 58 Second Floor 59 Terrace Floor 60 Providing and fixing 18mm thick gang saw cut mirrorpolishedpremouldedandprepolished) machine cut for kitchen platforms, vanity counters,windowsills ,faciasand similar locationsofrequiredsizeofapprovedshade, colour andtexture laidover 20mmthick base cementmortar 1:4(1cement: 4coarse sand) withjointstreatedwithwhitecement,mixed with matching pigment, epoxy touch ups, includingrubbing,curing,mouldingand polishing to edges to give high gloss finish etc. completeatalllevels.Graniteofanycolour and shade. Ground Floor 61 First Floor 62 Second Floor 63 Terrace Floor 64 Providingandfixing18mmthickgangsaw cut, mirror polished,premoulded and prepolished,machinecutforkitchen platforms,vanitycounters,windowsills, facias and similar locations of required size, approvedshade,colourandtexturelaid over20 mm thick base cementmortar 1:4 (1 cement:4coarsesand),jointstreatedwith whitecement,mixedwithmatchingpigment, epoxytouchups,includingrubbing, curing,moulding andpolishing to edges to give high gloss finish etc. completeat all levels.Graniteofanycolour and shade. Ground Floor 65 First Floor 66 Second Floor 67 Terrace Floor 68 Providing and laying Ceramic glazed floor tilesofsize300x300mm(thicknesstobe specifiedbythemanufacturer)of1stquality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing thejointswithwhitecementandmatching pigment etc., complete. Ground Floor 69 First Floor 70 Second Floor 71 Terrace Floor 72 Providing and fixing Ist quality ceramic glazed walltilesconformingtoIS:15622(thickness tobespecifiedby the anufacturer),of approvedmake,inallcolours,shadesexcept burgundy,bottlegreen,blackofanysizeas approvedbyEngineer-in-Charge,inskirting, risersofstepsanddados,over12mmthick bed of cement mortar 1:3 (1 cement : 3 coarse sand) andjointing withgrey cementslurry @ 3.3kgpersqm,includingpointinginwhite cement mixed with pigment of matching shade complete. Ground Floor 73 First Floor 74 Second Floor 75 Terrace Floor 76 Kota stone slab flooring over 20 mm (average) thickbaselaidoverandjointed withgrey cementslurrymixedwithpigmenttomatch theshadeoftheslab,includingrubbingand polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick Ground Floor 77 First Floor 78 Second Floor 79 Terrace Floor 80 Kotastoneslabs20mmthickinrisersof steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarsesand)and jointedwith greycement slurry mixed with pigment tomatch the shade of the slabs, including rubbing and polishing complete. Ground Floor 81 First Floor 82 Second Floor 83 Terrace Floor 84 Making plinth protection 50mm thick of cementconcrete1:3:6(1cement:3coarse sand (zone-III) derived from natural sources : 6 gradedstoneaggregate20mmnominalsize derived from natural sources) over 75mm thick bedof dry brick ballast40mmnominalsize, wellrammedandconsolidatedandgrouted withfinesand,includingnecessary excavation,levelling&dressing&finishing the top smooth. 85 ProvidingandfixingISImarkedflushdoor shutters conforming to IS : 2202(Part I) non- decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering withverticalgrainsorcrossbandsandface veneers on both faces of shutters: (a)35mmthickincludingISImarked Stainless Steel butt hinges with necessaryscrews. Single leaf. 86 (b) Double leaf 87 Providing and fixing factory made solid Foam uPVC profile for kitchen cabinet frame (45 x 20 mm) of approved shade, quality and make. Theprofile shall be laminated on both sides, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frameshall be fire retardent with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastner with necesary stainless steelscrews, all complete as per direction of Engineer-in-charge 88 Specifications for cupboard shutter, lipping in pelmet, teak wood lipping, uPVC casement/sliding window & door and Fire resistant glazed doors, windows & partition have been incorporated have been added. The specification Clauseshiftedto Sub Head 8 (cladding work) under clause No. 8.15. Specification of Nickel plated M.S. Pipe curtain roads, M.S. grills in frames of window, Bamboo Jaffery/ fencing, wooden moulded corner beading, magnetic catchers, powder coated telescopic drawer channel, slidling arrangement in racks/ cupboards/ cabinets shutter, hardware fittings for uPVC door/ windows, prelaminated medium density fibre board and stainless handles have been incorporated. 89 Providing and fixing factory made door frame (single rebate) made out of single piece extrudedsolidPVCfoamprofilewith homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement,includingfixingtheframetowall withsuitabledia&lengthanchorfasteneras permanufacturersspecificationand irection of Engineer-in-charge. 90 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Ground Floor 91 First Floor 92 Second Floor 93 Terrace Floor 94 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) sqm 116.90 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqmGround Floor 95 First Floor 96 Second Floor 97 Terrace Floor 98 Providingandapplyingwhitecementbased putty of average thickness 1 mm, of approved brandandmanufacturer,overtheplastered wallsurfaceto preparethe surfaceevenand smooth complete. Ground Floor 99 First Floor 100 Second Floor 101 Terrace Floor 102 Providingandfixing150mmbrightfinished floor brass door stopper with rubber cushion, necessarybrassscrewsetc.to suitshutter thickness complete. 103 Providing&fixingStainlesssteelslidingdoor bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . 104 Providingand fixing stainless steel towerbolts (barreltype)withnecessaryscrewsetc.complete (a) 300 mm x 10mm 105 (b) 200 x 10mm 106 Providing and fixing stainless steelhandles with screws etc. complete (a) 125 mm 107 Providing & fixing glass planes with putty and glazingclipsinsteeldoors,windows, clerestorywindows,allcompletewith:4.0mm thick glass panes 108 Construction of drain alongwith apron. 109 Chequerredprecastcementconcretetiles22 mm thick in footpath & courtyard, jointed with neat cement slurrymixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4(1cement: 4coarse sand).Ordinary cement without any pigment 110 Fitting of cast iron railing 111 Extra for openable side / top hung vision glass panels (IGUs)includingproviding and supplying at site all accessories and hardwares for the openable panels as specified and of the approvedmakesuchasheavydutystainless steelfrictionhinges,min4-pointcremone lockingsetswithstainlesssteelplates, handles,buffersetc.includingnecessary stainlesssteelscrews/fasteners,nuts,bolts, washersetc.allcompleteasperthe Architecturaldrawings,aspertheapproved shop drawings, as specified and as directed by the Engineer- in- Charge. 112 Providing and applying 12 mm thick (average) premixed formulatedone coat gypsum lightweight plaster having additives and light weightaggregates as vermiculite/ perlite respectively conforming to IS: 2547 (Part- 1 & II) 1976, applied on hacked / uneven background such as bare brick/block/ RCC work on walls & ceiling at all floors and locations, finished insmooth line and level etc. complete. sqm 468.90 113 Shingles roof tilesThe cement-mortar ratio for tile roofing is typically 1:3, which means 1 part cement and 3 parts sand. This ratio is suitable for most types of tile installation, including ceramic and porcelain tiles. The thickness of the mortar bed for tile flooring should be at least 3/8 inch, but no more than 3/4 inch 114 Planting and greenery with installation as per given details 115 ELECTRICAL WORK 116 Wiring for the light points with following size PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in existing concealed or surface mounted 25 mm dia 16 gaugeMS black enamelled Conduit including wire connectors complete in all respect. 2 x 2.5sq.mm +1 x 2.5sq.mm (DB to Keypad switch) 117 2 x 2.5sq.mm +1 x 2.5sq.mm (DB to switch board) 118 2 x 1.5sq.mm + 1 x 1.5 sq.mm(Switch board to Light First Point) 119 2 x 2.5sq.mm +1 x 2.5sq.mm(2way Switch board to 2way Switch board) 120 Wiring for the power points with following size PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in existing concealed or surface mounted 25 mm dia 16 gaugeMS Conduit complete in all respect. (for power points) 2 x 4.0sq.mm +1 x 4.0 sq.mm (DB to 16A socket) 121 2 x 4.0sq.mm +1 x 4.0 sq.mm (16A to 16A socket) 122 2 x 2.5sq.mm +1 x 2.5 sq.mm (16A to 6A socket) 123 2 x 2.5sq.mm +1 x 2.5 sq.mm(DB to 6A socket) 124 2 x 2.5sq.mm +1 x 2.5 sq.mm(6A to 6A socket) 125 2 x 6.0sq.mm +1 x 6.0 sq.mm (DB to 25A socket) 126 Supply & fixing of following size/module GI Box along with modular base & cover plate for modular switch sockets as required. 1/2MODULE BOX 127 3 MODULE BOX 128 4 MODULE BOX 129 6 MODULE BOX 130 8 MODULE BOX 131 Supplying & fixing of following modular switch, socket on existing modular cover plate & switch box including connection but excluding modular plate etc. as required. 16A SP SOCKET 132 16A SP SWITCH 133 32A SP SWITCH 134 25A SP SOCKET 135 USB 136 Supply,Shifting, storing, Installation, testing & Commissioning of the following lighting fixtures with all fixing accessories etc. as required.28WATT LED LIGHT 137 32 WATT PANEL LIGHT 138 9 WATT LED DOWN LIGHTER 139 7 WATT LED DOWN LIGHTER 140 36 WATT (600X600) LED LIGHT FIXTURE 141 WALL WASHER LIGHT 142 READING LIGHT(3WATT) 143 FLOOR LAMP 144 NIGHT LIGHT POINT 145 MIRROR LIGHT (5WATT) 146 WALL BRACKET LIGHT-A(3 WATT) 147 BOUNDRY BRACKET LIGHT 148 LED COVE LIGHT 149 Supply and fixing of following sizes perforated type Hot dipped GI cable trays including support, nut bolts, bend, tee, reducers etc. & hanging arrangement as required. Thickness of Cable Tray upto size 300mm-1.6mm thicknessThickness of Cable Tray above 300mm - 2mm thickness50X50MM 150 75X50MM 151 100X50MM 152 150X50MM 153 200X50MM 154 Supplying , laying & Commissioning of following 1100 volt grade XLPE insulated PVC sheathed aluminium /copper conductor armoured cables as per specification in existing trenches, cable trays, ducts, clamped includes anchor fasteners wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning. 3.5CX120 Sqmm Al.. Ar. XLPE cable 155 3.5CX150 Sqmm Al.. Ar. XLPE cable 156 Cable end termination of the following XLPE insulatedPVC sheathed aluminium / copper conductor armoured cables of 1100 volt grade including supplying and fixing of crimping aluminium/copper lugs, double compression glands with earthing facility at both ends of cables etc. complete as required. 3.5CX120 Sqmm Al.. Ar. XLPE cable 157 3.5CX150 Sqmm Al.. Ar. XLPE cable 158 DISTRIBUTION BOARD Supply, unloading, shifting, installation, testing & commissioningof following Distribution Boards with IP 42 along with copper bus-bar, neutral links and earth terminals all enclosed in MS box complete with hinges, metal covers, interconnections bonding to earth:- Make : Schneider / Legrand RDB-1 First & SecondDB (12 WAY SPN DB) 159 LPDB-1PANEL ROOM (8WAY TPN DB ) Incomer- 1 No.40A 4P MCB (10KA ) 3 No. 40A DP RCCB 30mA at each incomer Outgoing- 7 Nos. 16A DP MCB (10KA) 160 LPDB-2(12WAY TPN DB ) Incomer- 1 No.40A 4P MCB (10KA ) 3 No. 40A DP RCCB 30mA at each incomer Outgoing- 16 Nos. 16A DP MCB (10KA) 14 Nos. 6A SP MCB (10KA) 161 Supply, installation, testing and commissioning of flush / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shall / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shallDust cover/ blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover should be provided to protect jack wiring. Quoted priceshall be inclusive of 1.6 mm thick GI Boxes. Single outlet faceplate with RJ-45 jack 162 Supply, Laying, of Cat-6 cables in existing conduit. 163 Single outlet faceplate with RJ-11 jack 164 Supply, Laying, of Cat-6 cables in existing conduit. 165 Supply and fixing ofPVC conduits in following sizes including cost of junction boxes, bends, elbows, sockets, tees etc. laying in slab, cutting chases and making good or surface mounted including all fixing hardware. 25 mm Dia PVC Conduit 1.6 mm wall thickness. 166 LV side works (WIFI ) Containment Only Supply, installation, testing and commissioning of flush / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shall / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shallDust cover/ blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover should be provided to protect jack wiring. Quoted priceshall be inclusive of 1.6 mm thick GI Boxes. Single outlet faceplate with RJ-45 jack 167 Supply, Laying, of Cat-6 cables in existing conduit. 168 LV side works (TV ) Containment Only Supply, installation, testing and commissioning of flush / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shall / TIA - 568 - B.2-1 and IEC 60603-7-4. The plastic shallDust cover/ blank shall be provided to protect unused faceplate openings. Termination caps and plastic cover should be provided to protect jack wiring. Quoted priceshall be inclusive of 1.6 mm thick GI Boxes. Single outlet faceplate with RJ-45 jack 169 Supply, Laying, of CO-AXIAL cables in existing conduit. 170 Cameras Dome Fixed lens camera 2 MP - Supply, Installation, Testing & Commissioning ofIP Network TDN Low-Light IR Dome Camera, 1/2.7 CMOS, 2 MP @ 25fps or better, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 × 1080, 2.8 mm lens, BLC, HLC, 3DNR, Privacy Mask, 3 IR LEDs Smart IR with upto 15m IR distance, inbuilt mic , Audio support, 128GB SD card support, PoE, IP66, IK10 H.265, PoE Class 3 and 12V DC, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant. 171 Bullet camera 2 MP - Supply, Installation, Testing & Commissioning ofIP Network TDN Low-Light IR Dome Camera, 1/2.7 CMOS, 2 MP @ 25fps or better, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 × 1080, 2.8 mm lens, BLC, HLC, 3DNR, Privacy Mask, 3 IR LEDs Smart IR with upto 15m IR distance, inbuilt mic , Audio support, 128GB SD card support, PoE, IP66, IK10 H.265, PoE Class 3 and 12V DC, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant. 172 Supply , Installation , Testing and commissioning of 16 Channel NVR (Network Vedio Recorder), for recording upto 64CH @ 1080P with 08 nos. SATA HDDs minimum 64TB storage or more (recording requirement all cameras recording at 2MP, 25fps for 30 days),H.265/H.264/MJPEG/MPEG4 codec decoding, Front Control Pannel with LEDs Indication, 3 nos. USB, iPhone; iPad; Android based Mobile clients, Video Export feature on USB, Search Mode: Time/Date; Alarm; Motion Detection (MD); Exact Search (accurate to a second); Smart Search, Dual HDMI Output, Alarm Input (16 nos.), Alarm Output (6 nos.), 16 POE Ports,eSATA Device, 320Mbps each Incoiming & Outgping throughput, Operating Temperature –10°C to 55°CCertification : CE, FCC & UL including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge. 173 Supply, installation & testing of 12 Port Layer 2 POE switchwith 12 Port LIU. 174 Supply, installation & testing of 32 Monitor Screen complete as required. 175 Supply, installation & testing of CAT-6 cable with all termination, crimping etc. 176 Supply, installation & testing of 25mm PVC FRLS1.6mm thick Conduit. 177 UPS SYSTEM Supply, storing, shifting to location of installation, installation, testing & commissioning of following ratings UPS as per Specification, Technical Data sheet & IS. 178 Supply, Installation, Testing and Commissioning of (3 phase, 4 wire IN & 3 phase, 4 wire OUT) 7.5KVA online UPS system suitable for input and output parameters strictly as per specifications with built in isolation transformer. The UPS shall be provided in powder coated fan cooled enclosure painted in colour as per specifications. The UPS shall be suitable for normal, emergency, recharge, by-pass and maintenance mode.The system be expandable in such a manner that addition of another UPS of similar capacity can double the system output with common by-pass. The UPS shall have a microprocessor based display and control panel.UPS shall have enclosed batteries with rack, having 30 minute back-up.Make: APC / Numeric-Legrand / Emerson Input voltage : 380V to 480V,3ph+N+PE±10% Output voltage : 415 V,3 phase ±2% Battery charger Auto / Manual float cum Boost .The rate shall include overvoltage cut-off , undervoltage trip. 30 KVA Online UPS System with 30 minutes battery back-up. 179 PUBLIC ADDRESS SYSTEMSupplying, installing, testing and commissioning of 1.5W ceiling mounted type speakers with multi-tapping capable to produce minimum sound level of 75db at 3m distance. (Ceiling Speakers) 180 Supply, installing, testing and commissioning of 2c x1.5 sq. mm, PVC insulated FRLS copper armoured cable (screen shielded) confirming to IS standards and specifications. Complete as required as per technical specification. 181 25 mm Dia recessed PVC FRLS conduit to be used for Speakers for better connectivity and terminations to all speakers 182 LT Panels Supply , installation, testing & commissioning of Main LT panel/ Capacitor Panel/ Main distribution panels/ sub- distribution panelsfabricated out of 2 mm thickCRCA sheet steel in cubicle formation, compartmentalized, from 3b construction, free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and/ or flats wherever necessary. 1.6 mm thick CRCA sheet steel shall be used for final distribution panels. 3 mm thick cable gland plates shall be provided on top as well as at the bottom ofthe panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 No. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3 phase, 4 wire,50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings beforefabrication. Panel shall be with IP-55 protection. MAIN LT PANEL ( FOR DETAIL REFER ELETRICAL SLD) 183 CAPACITOR PANEL ( FOR DETAIL REFER ELETRICAL SLD) 184 HVAC PANEL ( FOR DETAIL REFER ELETRICAL SLD) 185 GROUND FLOOR PANEL( FOR DETAIL REFER ELETRICAL SLD) 186 FIRST FLOOR PANEL( FOR DETAIL REFER ELETRICAL SLD) 187 SECOND FLOOR PANEL( FOR DETAIL REFER ELETRICAL SLD) 188 TERRACE FLOOR PANEL( FOR DETAIL REFER ELETRICAL SLD) 189 PLUMBING PANEL( FOR DETAIL REFER ELETRICAL SLD) 190 UPS PANEL( FOR DETAIL REFER ELETRICAL SLD) 191 DG SET (100 KVA DG) Supplying, installation, testing and commissioning of silent type DG set, AMF panel, bus ducting/cable for DG sets to essentials panels synchronizing panel where required, DG sets enclouser room sound insulation/ventilation/smoke exhaust as required, earthing of DG sets system, control cabling, fule tank/piping, DG sets exhaust piping/exhaust chimney as per CPCB norms, Civil work connected with DG sets including foundation as required. 192 HT CABLES The rates under this section shall also include the following: Providing and fixing approved cable supports and grouting the same as required. Effecting proper connections at terminations. Providing all, fixing accessories such as clamping devices, nuts and bolts etc. Clamping to supports where laid in trenches. Providing proper supports for cable terminals as called for. Wherever cables cross walls provide proper sleeves at the time of civil work. Supplying , laying & commissioning of11 KV grade XLPE aluminium conductor armoured cables laid in trench. 1R x 3 C x 35 sq.mm 11 kV XLPE HT cable ( HT Metering to CSS HT Panel)(Note: Actual Length shall be checked at site) 193 Supplying and making cable end terminations for11 KV grade, XLPE aluminium conductor armoured cable including termination kit complete heat shrinkable sleeve etc. 1RX3 C x 35 sq.mm11 kV XLPE HT cable 194 PLUMBING WORK 195 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 196 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 197 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P.brass pillar tap 198 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia 199 Providing and fixing 100 mm sand cast Iron grating for gully trap. 200 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia 201 25 mm dia 202 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32mm dia 203 40mm dia 204 Providing and fixing gun metal gate valve with C.I. wheel of approved quality {screwed end):. 32mm dia 32mm dia 205 40mm dia 206 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore 207 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore 208 Providing and fixing brass stop cock of approved quality : 15 mm nominal bore 209 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter 210 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 211 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 212 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 213 Providing and fixing 600x450 mm beveled edge mirror of superior glass (ofapproved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 214 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 15 mm nominal bore 215 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mm 216 Providing and fixing C.P. brass angle valve for Basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore 217 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern 218 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 219 Providing and fixing CP Brass Single lever wall mixer of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia 220 DRAINAGE WORK Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 221 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand (zone-iii) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 222 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 223 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 224 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 225 Centering and shuttering including strutting, propping etc. and removal of form forWalls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 226 Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. 227 Steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo-mechanically treated bars of grade fe-500D or more. 228 WATER SUPPLY WORK Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layersnot exceeding 20 cm in depth, including consolidating each deposited layer by ramming,watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 229 Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS : 8329: 100 mm dia Ductile Iron Class K-9 pipes 230 150 mm dia Ductile Iron Class K-9 pipes 231 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : 100 mm diameter pipe@ 5.0mc/c 232 150 mm diameter pipe@ 5.0mc/c 233 Providing and laying S&S C.I. standard specials such as tees, bends, collars, tapers, caps etc. (Heavy class) Up to 300 mm dia 234 Providing and laying S&S C.I. Standard specials suitable for mechanical jointing as per IS : 13382 Up to 300 mm dia 235 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 236 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testingof joints complete as per direction of Engineer in Charge. External work 20mm nominal outer dia pipes 237 25mm nominal outer dia pipes 238 50mm nominal inner dia pipes 239 40mm nominal inner dia pipes 240 80 mm nominal dia Pipes 241 Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 20mm nominal bore 242 25mm nominal bore 243 Providing and fixing gun metal gate valve with C.I. wheel of approved quality {screwed end): 25mm nomiinal bore 244 32mm nomiinal bore 245 50mm nomiinal bore 246 40mm nomiinal bore 247 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) :50 mm dia 248 80 mm dia 249 Provideing and fixing C.I. Sluice Valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separtely): 100mm diameter Class II 250 150mm diameter Class II 251 Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 252 SEWERAGE WORK Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 253 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 254 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming to IS : 4885 255 Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With Sewer bricks conforming IS : 4885 256 Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With Sewer bricks conforming IS : 4885 257 Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : With Sewer bricks conforming IS : 4885 258 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 259 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 260 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes. 261 SEPTIC TANK & SOAK PIT 262 Earthwork inexcavationoverareas includingdisposalofexcavatedearth,leadupto50m, disposed earth to be levelled and neatly dressed.In all kind of soil upto 1.5m depth 263 In all kind of soil upto 1.5m to 3.0m. depth 264 Providingandlayingofcementconcretein base excluding the cost ofcentring and shuttering by 1:2:4 (1 cement : 2 coarse sand :4 gradded stone aggregae 20mm nominal size) 265 Brick work with brick of class designation 150 infoundationandplinthincementmortar(1cement : 4 coarse sand) 266 Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC Column 267 Reinforcement for R.C.C. work including, straightening, cutting bending binding andplacing in position complete. 268 Centringandshutteringincludingstruting,proping etc and removal of form for slab. 269 15mm cement plaster on rough side of mix 1:4(1 cement : 4 course sand) 270 Providing M.S.footrestincluding fixing with 20x20x10cm.cementconcrete block1:3:6(1 cement : 3 coarse sand : 6 gradded aggregate of nominalsize20mm)asperstandarddesignwith 20x20mm sq bars. 271 ProvidingandfixingC.I.teeattheinletand outlet of septic tank. 272 Providing & fixing 75mm dia vent pipes. 273 Providing&fixingof 75mmdiacastironterminal guard. 274 ProvidingandfixinginpositionprecastRCC manhole cover and frame of required shape and approved quality. M.D. -10- Circularshape 500mm internaldiameter 275 L.D. -2.5- Circular shape 450mm internaldiameter 276 Making soak pit 2.5 m diameter 3.0 metre deep with45x45cmdrybrickhoneycombshaft withbricksofclassdesignation75andS.W. drain pipe 100 mm diameter, 1.8m longcomplete as per standard design. With F.P.S. bricks 277 RAIN WATER HARVESTING 278 Earth work In excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5m in width as per as 10 sq.m on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed.All kinds of soil 279 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering , lead up to 50 m and lift up to 1.5m. 280 Extra for every additional lift of 1.5 m or part there of in: All kinds of soil. 281 Centring and shuttering including strutting, proppintg etc. and removal of form for: Suspended floors,roofs, landings, balconies and access platform. 282 Small lintels not exceeding 1.5m clear span, moulding as in cornices, windowsills,string courses, bands, copings, bed plates, anchor blocks and the like. 283 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. 284 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg/Cum 285 Brick work with common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in Cement mortar 1:6 (1 cement : 6sand) 286 12 mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand). 287 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete:200 mm diameter 288 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved qualityL D- 2.5 Rectangular shape 600x450mm internal dimensions 289 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 Sq.M on plan) including dressing of sides and ramming ob bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, withen a lead of 50m.All kinds of soil 290 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil 291 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering , lead up to 50 m and lift up to 1.5m. 292 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level. Concrete of M25 grade with minimum cement content of 330 kg/Cum 293 Centring and shuttering including strutting, proppintg etc. and removal of form for: Suspended floors,roofs, landings, balconies and access platform. 294 Edges of slabs and breaks in floors and walls, Under 20 cm wide 295 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars.(TMT) 296 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 297 12 mm thick cement plaster of mix1:4 (1 cement : 4 fine sand). 298 Providing, laying and jointing glazed stoneware pipes grade A with stiff mixture of cement mortar in the proportion of 1:1 (1 cement: 1 fine sand) including testing of joints etc. complete:200 mm diameter 299 Boring/drilling bore well of required dia for Casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia. 300 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 150 mm nominal size dia. 301 Supplying, filling, spreading and leveling gravels of size range 5 mm to 20 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge 302 Supplying, filling, spreading and leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer-in-charge. 303 ProvidingandfixingfactorymadeprecastRCCperforateddrain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four no longitudinal and 9 nos crosssectionalT.M.T.hoopbars,includingproviding 50mmdia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mmx1.6 mm complete, all as per direction of Engineer-in-charge. 304 Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm to window frames etc. including 62x19 mm beading of second class teak wood and priming coat with approved steel primer all complete. 305 ProvidingandlayingbelowgroundunplasticisedPVCpipeto withstand workingpressure of4kglcm2 soildwastepipes confirmingto IS:13592 and IS:4985 includingjointing with seal ringconfirmingtoIS :5282leaving 1Ommgapforthermal expansionallnecessary fittingsetc. complete.Excavationto be paid seperataly. 160 mm diameter OD 306 Providing and fixing unplasticised PVC moulded fittings/accessoriesforunplasticisedRigidPVCsoilandwastepipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm 307 Bend 87.5° 110 mm bend 308 BOUNDARY WALL 309 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as wellas10Sqmonplan)includingdisposalof excavatedearth,lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 310 Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. 311 Providingandlayinginpositioncementconcreteofspecifiedgrade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8(1Cement: 4coarsesand: 8gradedstoneaggregate 40mm nominal size) 312 Reinforcedcementconcreteworkinbeams,suspendedfloors,roofs havingslopeupto15°landings,balconies,shelves,chajjas,lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC Beam 313 Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC Footing 314 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Column 315 BrickworkwithcommonburntclayF.P.S.(nonmodular)bricksof class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarsesand) 316 HalfbrickmasonrywithcommonburntclayF.P.S.(nonmodular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 317 SteelreinforcementforR.C.C.work includingstraightening, cutting, bending,placinginpositionandbindingallcompleteuptoplinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) 319 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 320 Painting withsyntheticenamelpaintof approvedbrandand manufactureofrequiredcolourtogiveanevenshade.Twoormore coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture : (M.S. works). 321 Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) sqm 116.90Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 322 Providingandapplyingwhitecementbased putty of average thickness 1 mm, of approved brandandmanufacturer,overtheplastered wallsurfaceto preparethe surfaceevenand smooth complete. 323 C.C. ROAD 324 Earthworkinexcavationbymechanicalmeans (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to belevelled andneatly dressed. (D.S.R. 2.6.1) 325 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 326 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1Cement:4coarsesand:8gradedstone aggregate 40 mm nominal size) (D.S.R. 4.1.8) 327 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine 328 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. 329 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 330 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, j ointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making j oints with or without grooves (thickness of j oints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 331 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 332 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in positionandbindingallcompleteuptoplinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.(D.S.R-5.22.6) 333 FIRE FIGHTING SYSTEM 334 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required MAKE-ALLIED ENGINEERS/MAK ENGINEERS/CPRI APPROVED INCOMING250A, 50kA4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTsetc. LED type RYB phase indicating lamps, ON, OFF, tripindicating lampsSet of CopperBus Bar 300A OUTGOING( Note : All outgoing feeders for pumps should havedigital Ammeter with selector switches, and LED typeON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fullyautomatic Star/Delta starter suitable for 60 HP pumpwith overload protection, current sensing type singlephase preventor complete with all acceessories andinternal wiring required for automatic operation,selector switch for local/remote, aut Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitableHP fully automatic Star/Delta starter with overloadprotection, current sensing type single phase preventorcomplete with all acceessories and internal wiringrequired for automatic operation, selector switch forlocal/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL Control for diesel engine comprising Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual modeIndicating lamp for high/ Low Lub. Oil pressure, HighWater Temp and Engine on indicationBattery charger suitbale for 12V/24 V DC with boostand trickle selector switch, 0-30 V DC volt meter, and 020 A DC Ammeter All standard relays and accessories for automatic operation of diesel engineSystem Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 335 Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air releasevalve on top and flanged connection to riser, drainarrangement with 25 mm dia gun metal wheel valvewith required accessories, pressure gauge andpaintingwith synthetic enamel paint of approved shadeas required. 336 Supply, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 150MM DIAMAKE- TYCO/MINIMAX/CEASEFIRE. (Pressure etc. to complete the system as required) 337 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel Make - NEW AGE / MINIMAX 338 Supplying and fixing first-aid 30 mtr Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. Make EWAGE/CEASEFIRE/MINIMAX 339 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required Gun Metal Make NEWAGE/CEASEFIRE/MINIMAX 340 Providing and fixing Fire FHC Door 5 mm thick glass door (with M.S. frame) of size 2.1 m x 0.9 m with center opening for fire hose cabinet. Suitably marked on the outside with the letters FIRE HOSE including locking arrangement. All M.S. work to be in Red P.O. colour over appropriate primer. 341 Supply, laying, testing & commissioning of C class heavyduty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame andpainting with two or more coats of synthetic enamel paint of required shade complete as required :. Make TATA/SAIL/JINDAL 150 mm dia 342 100 mm dia 343 80 mm dia 344 50 mm dia 345 32 mm dia 346 25 mm dia 347 Providing and fixing forged brass ball valve with forged brass ball of the followingsizeincluding providing necessary union / flange. 25mm 348 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required Make CASTLE/C&R/ADVANCE/KIRLOSKAR 150 mm dia 349 100mm dia 350 80 mm dia 351 Supply, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required Make : CASTLE/C&R/ADVANCE/KIRLOSKAR 150 mm dia 352 100mm dia 353 80 mm dia 354 65 mm dia 355 Supply, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.Make : DS ENGG/SANT/EMERALD 150 mm 356 100 mm 357 Providing & fixing double flanged flexicon rubber expansion joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required. 150mm dia 358 100mm dia 359 Supply fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories. Make Newage/Tyco/MINIMAX Pendent sprinkler 360 upright sprinkler 361 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : 100 mm dia 362 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required- 4 WAY 150mm diaMake NEWAGE/CEASEFIRE/MINIMAX 363 Supplying, installation, testing & commissioning ofsprinkler flexible pipe (UL Listed) of stainless steelcomplete with 15 NPT on reducer thread withmaximum working pressure of 175 PSI test pressure of875 PSI (Burst) with branch line (Inlet) 25mm NPTmale thread to sprinkler head (Outlet) 15mm NPTfemale thread with reducer, nipple, 2 side brackets,center bracket, stockbar of following sizes complete asrequired. For 700mm Length 364 For 1000mm Length 365 Supply and fixing of fire extinguisher, ABC Type 4.00kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 366 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity(ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 367 Supply and fixing of fire bucket, round bottom made of GI sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained amd locked, initially filledwith fine river sand, water as per direction of Engineer-in-charge. 368 Supplying, installation, testing & commissioningof Smoke detector complete with mounting base complete as required. 369 Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. 370 Supplying,installation,testing&commissioningresponseindicatoronsurface/ recess MS box having two LEDs metallic cover complete with all connections etc. as required. 371 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 372 Supplying, installation, testing & commissioning fire alarm sounder with facility to makeannouncement,mountedinM.S.box(16 SWG)withhingedcoverplate& suitable for operation with amplifier i/c line matching transformer etc. complete as required. 373 Supplying, installation, testing & commissioning of addresable fire control module complete as required. 374 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 375 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. 376 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. 377 Supplying,installation,testing&commissioningofaddressablephonecontrol module complete as required. 378 Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required. 379 Supplying and drawingof cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Two pair, 2-core, 1.5 sqmm 380 Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 381 Supplyandlayingof aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protectedwith burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly onnected with the earth conductor by clamps etc.70 sq. mm 3-1/2 core 382 35 sq. mm 3-1/2 core 383 25 sq. mm 3-1/2 core 384 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 385 Supply & fixing of pressure switch in M.S. pipe line including connection etc. as required. 386 Supply & fixing flow switch in following sizes M.S. pipe including connection etc as required.-100 mm dia 387 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. 388 M.S. GATE 389 Earth work in excavation by mechanical means (Hydraulic excavator)/manualmeansoverareas(exceeding30cmindepth. 1.5minwidthaswellas10Sqmonplan)includingdisposalof excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. (D.S.R. 2.6.1) 390 Fillingavailableexcavated earth (excludingrock) in trenches, plinth,sidesoffoundationsetc.inlayersnotexceeding20cmin depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (D.S.R. 2.25) 391 Providing and laying in position cement concrete of specified grade excludingthecostofcenteringandshuttering-Allworkupto plinthlevel:1:4:8(1Cement:4coarsesand:8gradedstoneaggregate 40 mm nominal size)(D.S.R. 4.1.8) 392 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands,plainwindowsills,staircasesandspiralstaircasesabove plinthlevel uptofloor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:RCC Beam (D.S.R 5.33.1.1) 393 Ready mix concrete M 25 = 1.00 cum. i/c placing of concrete, vibrating, leveling etc 5.33.1.1 Rate as per Item No.5.33.1.1 of SH:Raft Foundation(D.S.R 5.33.1.1) 394 Rate as per Item No.5.33.2.1 of SH: Reinforced Cement Concrete cum 0.50 9860.40 4930.20 A Deduction of pumping charges.Column (D.S.R=5.33.2.1) 395 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinthlevel.Thermo-MechanicallyTreatedbarsofgradeFe-500D or more. (D.S.R. 5.22.6) 396 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) (D.S.R. 13.4.2) 397 Finishingwallswith water-proofing on cementpaint of approvedmakesuch as super snowcem,durrocem,robiacem,guttucem on undecorated wall surfaces(two coat) overone andincludingonecoatwhite cementprimertogiveaneven shade after thoroughly brushing the surface to powdered materialsincluding curing and cost of all materials.(D.S.R.-13.44.1) 398 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinthlevel.Thermo-MechanicallyTreatedbarsofgradeFe-500D or more. (D.S.R. 10.25.2) 399 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade.Two or more coatsonnewworkoveranundercoatofsuitableshadewith ordinary paint of approved brand and manufacture : (M.S. works). (D.S.R. 13.62.1) 400 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Uttar Pradesh View Result →
40.
Housing Urban and Rular Development #9443236 Technical Bid
Tender For Construction Of Chakrateertha Kund Complex And Other Truism Development Work At Naimisharanaya, District- Sitapur (U.P.), 1 Construction of Chakrateertha Kund Complex and Other Truism Development work at Naimisharanaya, District- Sitapur (U.P.) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil l (1.5m to 3.0m) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 6 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 7 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 9 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 10 Centring and shuttering including strutting,propping etc. and removal of form for 11 Foundations, footings, bases of columns etc. for mass concrete. 12 Suspended floors, roots, landings, balcnies and access platform. 13 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 14 Columns,Pillars, Piers, Abutments, Posts and Struts 15 Stairs,(excluding landings) except spiral-staircaces. 16 Weather shade,Chajjas, corbels etc. including edges 17 Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of deshutering and de centring at all levels over a height of 3.5 m ,for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roots, laning, beams and balconies (Plan area to be measured) 18 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 19 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. Concrete of M25 grade with minimum cement contant of 330 kg/cum All works upto plinth level 20 Concrete of M25 grade with minimum cement content of 330 kg /cum 21 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it’s components. System shall consist of metal profiles with an universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in-Charge. (Material shall conform to ASTM 6063). Floor Joint of 100 mm gap 22 Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Wall Joint of 100 mm gap 23 Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates an universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall conform to ASTM 6063). Roof Joint of 100 mm gap 24 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 25 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 26 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) 27 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 28 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red 29 Area of slab upto 0.50 sqm 30 Area of Slab over 0.50sqm 31 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work. 32 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 33 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 34 Providing and fixing 12 mm toughened glass partition with neccessary fittings and Applying clear silicon on joints complete in all respect. 35 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 36 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edge 37 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square. 38 Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). 39 Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick 40 Providing and fixing Single Glazing 6mm thick ET 125 series (Saint Gobain)toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor = 0.45, U-Value = (W/sq.m-K) 5.7W /M2K, Visible light transmittance = 0.30) 41 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 42 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortice lock with key cylinder fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 43 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 44 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 45 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 46 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 47 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.. 48 Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 49 Providing and fixing approved brand and manufacture SS 304 grade H type 900mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 50 Providing and fixing approved brand and manufacture SS 304 grade Center Patch Lock wih Cylinder complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 51 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness 52 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 53 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube 54 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 55 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete Fastener with threaded dia 10 mm 56 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backingfilled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : White sand stone - exposed face fine dressed with rough backing 30 mm thick 57 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 58 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases 59 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 60 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 61 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm 62 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm 63 Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 600x600 mm 64 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 65 Providing and laying 18 mm thick leather finish steel grey granite stone flooring in required design and patterns, in linear as well as curvilinear portions in building flooring, footpath etc. all complete as per the architectural drawings with over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 66 Providing and fixing machine cut, mirror/ eggshell 18mm thick leather finish steel grey granite stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 67 Applying breathable, non-reactive,antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 68 Supply, fabricating, transporting, hoisting and fixing in position good quality durable Mirzapur sand stone/ any other type of sand stone in various elements for all level all height.Stone shall be free from cracks, lines, stains, white spots of efflorescence and even in shade for each elements. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with differant process ofi.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding. The drawings provided are vary preliminary and amount of carving will be more then what is shown on the drawings. The carving and molding work shall be of very good quality. The stones to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architects. 69 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. White sand stone 70 Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. 71 Providing and fixing 40mm thick cladding comprising of Wooden framework using 25mx50mm sections at a maximum spacing of 600mm in any one direction (including adding members as required) covered with12mm thick BWP ply layered with 4mm thk. veneer on one sidepasted and pressed with adhesive to give a uniform and smooth finish, including4mm thk. S.S. strip framework on all sides of veneer panels with wooden member surround, top moldings / margins, melamine polish etc. to finish the thickness, as shown complete in drawing. All members / ply etc. shall be treated with anti-termite solution as per norms. No extra shall be paid for making of openings, door / window frames and for making provisions for electric conduits. etc. all complete as per direction of Engineer-in-charge. 72 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of colour Black, Cherry/Ruby Red or equivalent 73 Providing and fixing Granite stone gang saw cut (polished and machine cut) of thickness 18mm for wall lining, backing filled with a grout of average 12mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar with an admixture of pigment to match the granite shadeetc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 74 12mm cement plaster of mix : 1:6 (1 cement : 6 fine sand) 75 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand) 76 6 mm cement plaster to ceiling of mix : 1:3(1 cement: 3 coarse sand) 77 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 78 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 79 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 80 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 81 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two or more coats on new work 82 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre 83 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 84 Two or more coats on new work 85 Melamine polishing on wood work (one or more coat) 86 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 87 12.5 mm thick tapered edge Glass Reinforced Gypsum (GRG) board conforming to IS: 2095- (Part 3):1996 (Boards with BIS certification marks) 88 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 89 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron) 90 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminum (minimum thickness of powder coating 50 micron) 91 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 10 mm depth and 10 mm width 92 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 93 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm 94 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 95 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase 96 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. without disturbing the other structural elements. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) 97 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. without disturbing the other structural elements such as column, beams & slab. 98 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar 99 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. 100 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm 101 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 102 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 103 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 104 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 105 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. 106 Supplying and stacking at site dump manure screening by 4.75 mm sievefrom approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : 107 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost ofmanure, sludge or extra good earth if needed to be paid for separately) Holes 60 cm dia, and 60 cm deep 108 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 109 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 110 Providing and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. 111 Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy in big size HDPEbag as per direction of the officer-in-charge. 112 Providing and displaying of Dracaena margineta plant, having ht. 30 cm to 45 cm with colorful leaves, fresh and healthy in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge. 113 Complete maintenance of the entire garden features having as per yard stick in the garden area i.e lawn trees,shrubs, hedge, flower beds,foliages,creepers etc including hoeing, weeding pruning replacement of plants, gap filling, watering,mowing of lawn,grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecting sites,pesticide and fertilizers (whenever required) top dressing of lawn with good earth and menure and maintenance of other garden related works as directed by office in charge. (cost of good earth,menure, fertilizers, insecticide , pesticide,lawn mover and brush cutter with fuel will be provided by the department and other T/P material/articles shall be provided by the contractor. Open spaces (1Mali for 3.00 Acre). 114 Providing and fixing watercloset squatting pan (Indian type WC pan) with 100mm sand cast Iron P or S Trap, including wall hung cistern & installation kit with duel flush fitting (2.0/4.0 lts. per flushing), conforming to IS 7231, with all fittings & fixtures complete including cutting and making good the walls and floors wherever required.( MAKE-1 : JAQUAR, MODEL NO. INDIAN WC : ECS-WHT-453LE & CISTERN : WHC-WHT-184BTTG OREQUIVALENT.) White vitreous china Orissa pattern WC pan of size 415 x 515 x 255mm . 115 Providing and fixing white vitreouschina extended wall mountedwater closet of size 350 X 545 X 380mm of approved shape including providing and fixingof concealed cistern with duel flush fitting (2.0/4.0 lts. per flushing), including sheet cover, and cistern fittings, nut bolt gasket,chair etc complete. ( MAKE-1: JAQUAR, MODEL NO. WALL MOUNTED WC : FLS-WHT-5953 & CISTERN & FACE PLATE :JCS-WHT-2400SG & JCP-CHR-152415 OREQUIVALENT.) 116 Providing and fixing white vitreous china flat back half stall urinal of size 370 x 315 x 620mm with urinal valve auto closing system (0.75 lts. per flushing) with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :. ( MAKE-1: JAQUAR, MODEL NO. URINAL : URS-WHT-132530 & URINAL VALVE AUTO CLOSING :PRS-CHR-077G OREQUIVALENT.) 117 Providing and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with15 mm C.P. brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & BASIN MIXER :FLR-CHR-5001BG & WASTE COUPLING : ALD-CHR-705 OREQUIVALENT.) White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15mm CP Brass single hole basin mixer with flow rate 2.5 litre per minute at 3 bar . 118 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever requiredKitchen sink with drain board 119 510x1040 mm bowl depth 250 mm 120 Providing and fixing hand shower (Health faucet)with 1.2mtr long with 8mm dia Easy Flex Tube with wall hook and flow restrictor withflow rate 6 litre per minute at 3 bar in chrome finish and wall hook. ( MAKE-1: JAQUAR, MODEL NO. HEALTH FAUCET : ALD-CHR-573GA OREQUIVALENT.) 121 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ( MAKE-1: JAQUAR, MODEL NO. BOTTLE TRAP : ALD-CHR-769L300X190 OREQUIVALENT.) 122 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. For physically handicap person consisting of; 123 Wall mounted WC Pan-01 no. withbuilt in Jet of Cera CAT no.S1046105 124 Concealed Cistern Cistern-01 no.of Cera CAT no. B1110108 & Knob B1120118 125 Soft Close Seat Cover -01 no of Cera CAT no.B1520106 126 Wall hung Wash Basin -01 no of Cera CAT no.S2040147 127 Spatula Single leverCera CAT no F9030451 128 Wall mounted Grab bar 600 mm long - 2 nos of Cera CAT no.B2210106 129 Wall mounted Hinged hand rail 750 x 100-01 no Cera CAT no B2210108 130 Bottle Trap Cera CAT no F8060403 131 Waste Coupling Cera CAT no F8050101 132 Stainless soap dish Cera CAT no F5007106 133 Tissue paper holder Cera CAT no F5007110 134 Providing & fixing PVC waste pipe for sink including PVC waste fitting Complete40mm Dia 135 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 136 Providing & fixing toilet paper holder C.P. brass 137 Providing and fixingof fully automatic NO TOUCH durable & shock proof hand drier of approved make & manufacture suitable to operate on 220 volts, single phase 50 hz, A.C. power supply, 1500 Wattand directly plugged to power point complete in ABS plastic body having drying time 20-30 seconds complete as per direction of Engineer in Charge. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge. 138 Providing, Fixing of CP brass Towel Rack 600mm long without hanger with 3 hooks and CP brass screws complete as required. 139 Providing & fixing glass urinal partition of Height: 900mm,Width: 450mm &Frosted Safety Glass: 8 mm with fixed with expandable anchor fasteners with C.P. brass bolts and washers, embedded in wall with anchor and set in cement concrete complete including cutting and making good the walls wherever required. 140 Providing and fixing soil waste and vent pipesHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 75 mm dia. 141 Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron/ centrifugally cast iron(spun) pipes embedded in and including cement concrete blocks 10x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. 142 For 100mm dia pipe 143 Providing and fixing bend of required degree with access door insertion rubber washer 3mm thick, bolts and nuts complete 144 100 mm dia 145 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 146 75 mm dia 147 Providing and fixing plain bend of required degree: 148 100 mm dia 149 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 150 75 mm dia 151 100 mm 152 SS 304 grade coupling with EPDM rubber gasket 153 75 mm 154 Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun) iron pipe of diameter: 155 100mm 156 Providing and fixing trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent, arm complete, including cost of cutting and making good the walls and floors. 100mm inlet and 100mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 157 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. 158 Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe) 159 Total bracket length 810 mm of approved shape and design (for two 100 mm dia pipes) 160 Providing & fixing Nickel Chromium Platedliquid soap container/ dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. ( MAKE-1 : JAQUAR, MODEL NO. - ACN-CHR-1137N OR EQUIVALENT. 161 Providing, Fixing of CP brass Towel Ring with CP brass wall brackets and providing & fixing CP brass screws complete as required. ( MAKE-1: JAQUAR, MODEL NO. TOWEL RING : ACN-CHR-1121N OREQUIVALENT.) 162 Providing & fixing soap dish holder of approved design.( MAKE-1: JAQUAR, MODEL NO. SOAP DISH : ACN-CHR-1131N OREQUIVALENT.) 163 Providing and fixing white vitreous china Oval shaped wash basin for top/under counter mounting with 15 mm C.P. brass pillar tap of auto closing type of approved quality and make with, including painting of fittings and brackets, cutting and making good the walls whereever required. ( MAKE-1: JAQUAR, MODEL NO. WASH BASIN : FSS-WHT-29601 & PILLAR TAP :PRS-031G & WASTE COUPLING : ALD-CHR-705 OREQUIVALENT.) 164 White Vitreous China Oval shaped Wash basin size 545 x 545 x 180mm with 15 mm C.P. brass pillar tap auto closing type of approved make with flow rate 2.5 litre per minute at 3 bar . 165 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. ( MAKE-1: JAQUAR, MODEL NO. SINK MIXER : FLR-CHR-5163GD OREQUIVALENT.) 166 Providing , Fixing of CP Brass Shower Mixer with provision of overhead shower with 115mm long bend pipe, in built spout, spout/shower selector with flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. ( MAKE-1: JAQUAR, MODEL NO. SHOWER MIXER : FLR-CHR-5273UPRGD OREQUIVALENT.) 167 Providing,Fixing wall mounted Double Coat hookon door complete. ( MAKE-1: JAQUAR, MODEL NO. COAT HOOK : AKP-CHR-35761P OREQUIVALENT.) 168 Providing & fixing wall mounted 300mm Long SS Grab Bar including cutting & making good the walls. ( MAKE-1: JAQUAR, MODEL NO. GRAB BAR : AKP-CHR-35701PS OREQUIVALENT.) 169 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. ( MAKE-1: JAQUAR, MODEL NO. 2 WAY BIB COCK : FLR-CHR-5041NG OREQUIVALENT.) 170 Providibng and fixing straight type Macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of McAlpine, UK with integral single mould sealing fins made of flexible EVA body, including bush/adaptor for use with C.I. Pipe as supplied with the pan connector. 171 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing complete as required. (MAKE-ModiGuard Sparkle Mirror ) 172 Providing & fixing 100mm x 50mm G.I. waste with reducing elbow & nipple cutting chases, the floor / slab, repairs complete as required and connection to GI / CI waste pipe. 173 Providing and fixing cast brass Floor cleanout plug with suitable insert keys for opening in brass cap, male threaded joint/reducer with G.I. socket caulked to Pipe/fittings of CI pipe including cost of lead joints etc. complete in all respect.100 mm dia 174 Providing and fixing GI inlet fitting with maximum 3 inlets 32,40 or 50 mm size fabricated from 100 dia GI pipes andsockets,fixed to C.I. trap with Drip Seal joint and set in cement concrete as per standard drawing complete as directed by Engineer-incharge. 175 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge.Circular Type 125 mm nominal dia with 25 mm waste hole 176 Providing, Installing & fixing storage type water heater of approved shade with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 177 Capacity 15 litres size 448X448X345mm ( MAKE-1: JAQUAR, MODEL NO. GEYSER : ELENA OREQUIVALENT.) 178 Capacity 35 litres size 875X400mm ( MAKE-1: JAQUAR, MODEL NO. GEYSER : VERSA HORIZONTAL MANUAL OREQUIVALENT.) 179 Supplying fitting and fixing Ajoy Flowguard CPVC (Chlorinated Polyvinyl Chloride) pipes having thermal stability for hot and cold water supply including all CPVC Plain and bruss threaded fitting including clamps at 1.00 m spacing including joining of pipes and fitting with one step CPVC solvent cement and testing of joints complete at all levels as directed and spcified (In Terrace & Shaft- Hot Water Supply) 180 (Note: Ball Valve and union will be charged extra and does not comes under Accessories) In internal Wall - Exposed on Wall 181 20 mm OD 182 25 mm OD 183 32mm OD 184 40 mm OD 185 Providing and fixing GI pipes(IS:1239 Heavy Class) complete with GI fittings and clamps, i/c cutting and making good the walls etc.(In Terrace & Shaft- Cold & Flushing Water Supply) 186 Internal work - Exposed on Wall 187 25 mm nominal bore 188 32 mm nominal bore 189 50 mm nominal bore 190 Providing and fixing G.I. pipes(IS:1239 Heavy Class) complete with G.I. fittings including trenching and refilling etc.(For External Riser Pipe) 191 External Work 192 25mm nominalnominal bore 193 32mm nominalnominal bore 194 40mm nominalnominal bore 195 50mm nominalnominal bore 196 65 mm nominal nominal bore 197 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore 198 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 199 25mm nominal bore 200 32mm nominal bore 201 50mm nominal bore 202 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 203 20 mm nominal bore 204 25mm nominal bore 205 Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with brass unions : 45 cm length 206 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : 207 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 208 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 209 25mm diameter pipe 210 32mm diameter pipe 211 50mm diameter pipe 212 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 213 25mm diameter pipe 214 32mm diameter pipe 215 40mm diameter pipe 216 50mm diameter pipe 217 65mm diameter pipe 218 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 219 25mm diameter pipe 220 32mm diameter pipe 221 40mm diameter pipe 222 50 mm diameter pipe 223 65 mm diameter pipe 224 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 225 15 mm nominal bore 226 20 mm nominal bore 227 25 mm nominal bore 228 32 mm nominal bore 229 40 mm nominal bore 230 50 mm nominal bore 231 65 mm nominal bore 232 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 233 Providing and fixing C.P. brass Short body bib cock of approved quality conforming to IS:8931 with flow rate 2.5 litre per minute at 3 bar: (MAKE-1: JAQUAR, MODEL NO. SHORT BODY BIB COCK : FLR-CHR-5037NG OREQUIVALENT.) 15mm nominal bore 234 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms with flow rate 2.5 litre per minute at 3 bar. (MAKE-1: JAQUAR, MODEL NO. LONG BODY BIB COCK : FLR-CHR-5047NG OREQUIVALENT.) 15mm nominal bore 235 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. (MAKE-1: JAQUAR, MODEL NO. ANGLE VALVE : AQT-CHR-3057 OREQUIVALENT.) 236 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 237 50 mm dia 238 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. 239 Internal work - Exposed on Wall 240 65 mm diameter pipe 241 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work. 242 65 mm diameter pipe 243 Butterfly valve (manual) with C.I bodySS disc nitrile sheet & O ring & PN 16 Pressure rating as specified 100 mm nominal bore 244 65mm dia. 245 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 246 65mm dia. 247 Providing, laying and joining in position HDPE pipes with slipon flange, High density Poly Ethylene pipe and conforming to I.S. 4984-1995 of required grade / class, 16kg/sq.cm pressure and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. 248 110 mm dia. (OD) (16.0 kgf/sq cm.) 249 160 mm dia. (OD) (16.0 kgf/sq cm.) 250 Providing and fixing motorised butterfly valve with Control Panel & Float Type Magnetic Level Sensors suitable for 220-230 volts AC to operate valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box (upto 6 mt qty approx.) etc., complete. 32 mm dia 251 Supply installation, testing and commissioning of self-contained Drinking water cooler with inbuilt RO confirming to IS: 1475 with amendment no. 1 to 7, suitable for operation on 230 volts ± 10%, 50 Hz, single phase A.C. supply. The two tank inbuilt (hot & cold) and body casing of the water cooler shall be made out of stainless steel. The water cooler will be of following capacities with two numbers faucets / stop cocks (1 no Normal water & 1 no of hot water): Nominal Storage Capacity - 40 Ltrs. Hot water Storage Capacity - 40 Ltrs. 252 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 253 200 mm diameter S.W. pipe 254 250 mm diameter S.W. pipe 255 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 256 200 mm diameter S.W. pipe / RCC pipe 257 250 mm diameter S.W. pipe / RCC pipe 258 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180 x 150mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 259 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 260 300mm dia RCC pipe 261 450mm dia RCC pipe 262 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 263 Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5 264 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 265 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 Extra for depth for manholes: Size 90 x 80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 268 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 269 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 350 to 450 mm diameter 270 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 271 Excavating trenches of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,depth upto 1.5m including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. All kinds of soil Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 272 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: Ordinary rock Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 273 Hard rock (requiring blasting) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 274 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 275 Ordinary Rock 276 Hard Rock(requiring blasting) 277 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 278 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). 279 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia. 280 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer –in-charge. 200 mm nominal size dia. 281 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia. 282 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 283 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 284 Providing and fixing suitable size threaded mild steel cap/shoe or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 285 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 286 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 287 Butterfly valve (manual) with C.I bodySS disc nitrile sheet & O ring & PN 16 Pressure rating as specified. 80 mm dia. 288 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 16 rating as specified. 289 80 mm dia. 290 Providing and fixing 80mm dia GI pipes to IS:1239 heavy class with fittings. 291 Supply, Lowering, installation & testing of KSB make submersible pumping set with 10 HP motor 18 stage pump suitable for maximum capacity of 20 m3 hr. at 100 mtr. Head respectively. With Three Phase. 292 Providing & fixing cable 6 sq.mm. From submersible pump to panel board. 293 Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet. 294 Earth work in excavation by mechanical means (Hydraulicexcavator) / manualmeansoverareas(exceeding30cmindepth.1.5minwidthas well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 295 All kinds of soil 296 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 297 Extraforeveryadditionalliftof1.5morpartthereofinexcavation /banking excavated or stacked materials. 298 All kinds of soil 299 Providingandlayinginpositioncementconcreteofspecifiedgrade excluding the cost of centering and shttering - All work up to plinth level 300 1:4:8(1Cement:4coarsesand:8gradedstoneaggregate40mm nominal size) 301 Centering & shuttering including strutting, propping etc. and removal ofform work for: 302 Foundations, footings, bases of columns etc. for mass concrete. 303 Lintels, beams, plinth beams, girders, bressumers and cantilevers 304 Suspended floors, roofs, landings, balconies and access platform. 305 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 306 SteelreinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete upto plinth level. 307 Thermo-Mechanically Treated bars. 308 Providingandlayinginpositionmachinebatchedandmachinemixed design mix M-25 grade cement concrete for reinforced cement concrete work,usingcementcontentasperapproveddesignmix,including pumping of concrete to site of laying but excluding the cost of centering, shuttering,finishingandreinforcement,includingadmixturesin recommended proportions as per IS: 9103 to accelerate, retard setting of concrete,improveworkabilitywithoutimpairingstrengthanddurability as per direction of Engineer-in-charge. 309 All works upto plinth level 310 6mmcementplaster1:3(1cement:3finesand)onceiling/R.C.C. Beams etc. 311 Neat cement punning. 312 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 313 Providingandlayingnon-pressureNP2class(lightduty)R.C.C.Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 314 150 mm dia. R.C.C. pipe 315 Providing and fixing soil, waste and vent pipes 316 100 mm dia 317 Sand cast iron S&S pipe as per IS: 1729 318 Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 3989 319 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS : 1786,havingminimumcrosssectionas23mmx25mmandoverall minimum length 263 mm and width as 165 mm with minimum 112 mm spacebetweenprotrudedlegshaving2mmtreadontopsurfaceby ribbing or chequering besides necessary and adequate anchoring projectionsontaillengthon138mmasperstandarddrawingand suitabletowithstandthebendtestandchemicalresistancetestasper specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cmcementconcreteblock1:3:6(1cement:3coarsesand:6graded stone aggregate 20 mm nominal size) complete as per design. 320 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 321 Rectangular shape 600x450 mm internal dimensions 322 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 323 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 324 Constructingsoakpit1.20x1.20x1.20mfilledwithbrickbatsincluding S.W.drainpipe100mmdiameterand1.20mlongcompleteasper standard design. 325 Constructingbrickmasonrycircularmanhole1.22minternaldiaatbottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand)insidecementplaster12mmthickwithcementmortar1:3(1 cement:3coarsesand)finishedwithafloatingcoatofneatcement foundationconcrete1:3:6(1cement:3coarsesand:6gradedstone aggregate 40 mm nominal size) and making necessary channel in cement concrete1:2:4(1cement:2coarsesand:4gradedstoneaggregate20 mmnominalsize)finishedwithafloatingcoatofneatcement,all complete as per standard design : 326 1.68mdeepwithSFRCCoverandframe(heavydutyHD-20gradedesignation)560mminternaldiameterconformingtoI.S.12592,total weightofcoverandframetobenot lessthan 182kg. fixedin cement concrete1:2:4(1cement:2coarsesand:4gradedstoneaggregate20 mmnominalsize)includingcentering,shutteringallcomplete. (Excavation,footrestsand12mmthickcementplasterattheexternal surface shall be paid for separately) : 327 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 328 Extradepthforcirculartypemanhole1.22minternaldia(atbottom)beyond 1.68 m to 2.29 m : 329 With common burnt clay F.P.S. (non modular) bricks of class designation7.5 330 Excavatingtrenchesofrequiredwidthforpipes,cable,etc including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soilasrequired,inlayersnotexceeding20cmindepthincluding consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 331 All kinds of soil 332 Pipes cables etc. exceeding 80 mm dia. But not exceeding 300mm dia. 333 Providing, layingandjointingglazed stone warepipes grade class SP-1with stiffmixtureofcementmortarin theproportionof1:1 (1cement :1 fine sand) including testing of joints etc complete. 150 mm diameter 334 Providingandlayingcementconcrete 1 : 5 : 10 (1 cement : 5 coarsesand : 10 gradded stoneaggregate40 mm nominal size) alround S.W. Pipesincludingbed concrete as per standard design. 150 mm diameter S.W.Pipe 335 Earthwork in excavation by mechanical means ( Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, with in a lead of 50m. All kind of soil 336 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials 337 All kinds of soil 338 Qty for 1.5-3.0 M depth RWH & Desilt Chamber 339 Qty for 3.0-4.5 M depth RWH-Rate 2 Times 340 Qty for 4.5-5.75M depth-RWH -Rate-3 Times 341 Providingorange color safety foot rest of minimum 6mm thickplasticencapsulated as per IS : 10910 on12mm dia steelbar conformingto IS :1786 having minimum cross section as 23mm x 25mm and over allminimum length 263mm andwidth as 165mmwith minimum 112mm space between protrude legshaving2mm tread on top surface by ribbing or chequering besides necessary andadequate anchoring projections on tail length on 138mmas per standard drawing and suitable to with dtand the bendtest andchemical resistancetest as per specifications and havingmanufacturespermanent identification make to be visible even afterfixing, including fixing in manholes with 30x20x15cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 342 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) 343 12 mm cement plaster finished with a floating coat of neat cement of mix : 344 1:3 (1 cement: 3 fine sand) 345 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 346 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 347 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: 348 Cement mortar 1:6 (1 cement :6 coarse sand) 349 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 350 All types of soil 351 300 mm dia 352 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 353 200 mm nominal size dia 354 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 355 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 356 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 357 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 358 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge 359 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) 360 Centering and shuttering including strutting, propping etc. and removal of form for 361 Suspended floors, roofs, landings, balconies and access platform 362 Edges of slabs and breaks in floors and walls 363 Under 20 cm wide 364 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 365 TMTsteel bars 366 Providing, fixing, commissioing, testing and of open well submersible pump for each pump IP 58 protected electric enclosure comprising of 2 Nos. Electrical Driven Horizontal pumps with all accessories coupled to motor suitable for operation on 200-240 volts, 1 phase 2900 RPM. motor with SS 304 body all accessories such as NRVs, valves, common delivery header complete in all repsects. Pumps shall be suitable for 200-240volts 1 phase 50 Hz A.C supply & shall be having the following specifications. Moc of pump -Impeller- CI, csing - CI , shaft- SS 410. Delivery header including all GI pipes, CI valves, CI NRV, bourden type Pressure gauge & accessories complete. 367 All accessories for running two pumps with dry running protection etc. 368 FOR DOMESTIC TRANSFER PUMP 369 No. ofPumps: 2 (1 Working + 1 Stand by ) 370 Capacity:120 LPM 371 Head :30m 372 FOR GARDEN IRRIGATION PUMP 373 No. ofPumps: 2 (1 Working + 1 Stand by ) 374 Capacity:140 LPM 375 Head :30m 376 Submersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connectedto TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables, with both pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect 377 SUBMERSIBLE UNDER GROUND FOR BOREWELL 378 No. ofPumps: 1 (1 Working ) 379 Capacity:160 LPM 380 Head :60 m 381 SUBMERSIBLE UNDER GROUND FOR BOREWELL 382 No. ofPumps: 1 (1 Working ) 383 Capacity:160 LPM 384 Head :60 m 385 Supply installation testing and commissioning of filtration plant for kund cap. 50cum/hr. including pumps, filters, piping , valves and pumps complete in all respect. 386 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, up to 90 metre depth below ground level. 387 All Types of Soil 388 300mm dia 389 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All Types of Soil 300mm dia 390 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 391 200 mm nominal size dia 392 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 393 200 mm nominal size dia 394 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 395 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 396 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 397 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 398 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 399 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch modular plate suitable GI box and earthingthe point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. 400 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 401 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steelconduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. 402 Wiring for power plug points with 2 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 1 No. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. 403 Wiring for light plug points / power plug points with 4 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed steel conduit along with 2 Nos. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required. 404 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required 405 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 406 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 407 2x10 sq. mm + 1x6 sq. mm earth wire 408 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 409 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 410 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. 411 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. 412 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 413 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 414 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 415 Supplying and fixing brass batten/ angle holder including connection etc. as required. 416 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 417 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 418 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm 419 SITC of Input power : 20W LED, compact and minimilist surface mounted designed for ceiling & pendant mount. Beam angle 110°(Fixed). Luminaire made of extruded anodised aluminium (grade 6063) of high corrosion resistance, polycarbonate end caps and non corrosive stainless steel fasteners. Polycarbonate diffuser. Protection class IP20. Available colour temperature 3000K / 4000K / 5700K, Colour rendering index (CRI)>80. SDCM = 3 MacAdam. K-Lite LED module with expected service life of at least 50,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor>0.95, THD<10%, Surge protection 3KV. Luminaire dimension : 1200mm length x 43mm width x 52mm height. CE & BIS Certified. Inhouse NABL accredited lab.Make :- K-Lite /Ligman/ Unilamp 420 SITC of Input power : 18W led, ceiling mounted compact downlight. Beam angle 15° / 25° / 40°. Luminaire made of extruded aluminium, pressure die-cast aluminium alloy of high corrosion resistance and non corrosive stainless steel fasteners. Clear toughened glass of 4mm thickness. Gravity die cast aluminium plate for surface mounting on ceiling. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK07. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 100mm diameter x 150mm height. CE & BIS Certified. Inhouse NABL accredited lab. Make :- K-Lite /Ligman/ Unilamp 421 Supply, installation, testing & commissioning of 595mm/600mm mm long surface mounting type LED fitting with diffuser having a lumen output not less than 1100 lumens, CCT 4000K and LED efficacy better than 110 lumen/ watt with opal diffuser in polycarbonate complete with CRCA / Pressure Die Cast Aluminium Housing and life of 50K burning hours (L 70) at 30 deg , THD =10%, CRI better than 80 with inbuilt protection against short circuit, over voltage protection and surge protection of up to 2 KV including connections etc. as reqd. 422 Supplying and fixing of 250 mm sweep Exhaust fan with all accessories suitable for operation single phase 230 volt 50 cycle per second per sec. AC supply etc. as required. in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required. 423 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 424 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 425 6 way , Double door 426 12 way, Double door 427 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 428 8 Way (4+24), Double Door 429 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 430 For 6 way, Double door SPN MCBDB 431 For 14 way, Double door SPN MCBDB 432 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface / recess, complete with testing and commissioning etc.as required. 433 For 8 way, Double door TPN MCBDB 434 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 435 Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required. 436 25 Amp DP MCB 437 40 Amp DP MCB 438 Supplying and fixing of following rating, 240/415 volts, C curve, four pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63Amp FP MCB 439 Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 100 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required. 440 25 Amps 441 40 Amp 442 63 Amp 443 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 444 Design, Manufacturing, Supply, Installation, Testing & Commissioning of cubicle type totally enclosed free standing / Wall mounted type moisture, dust and vermin proof compartmentlized Floor Distribution Panel made out of 2.0 mm thick of Main members & front cover 1.6 mm thick CRCA sheet complete with internal wiring with suitablesize wires / cable, interconnection, painting complete as per specification & drawing. All the Multi Function Meter / KWH Meter shall be with RS 485 port / SCADA or BMS Connectivity. 445 The MCCB rating up to 250A shall have thermal megnatic based adjustable over current, short circuit protection and above 250A MCCB shall have microprocessor based adjustable over current, short circuit, earth fault protection. 446 All Main Distribution board / Sub Distribution board / Meter boards which are located inside various blocks shall be partially Type Tested assemblies (PTTA) as per conforming to IEC-61439-1 447 The Moulded Case Circuit Breaker shall have a minimum fault breaking capacity (Ics) of not less than 35 KA & 25KA RMS for one second at 415 volts for MDB / SDB respectively. MCCB‘s above 63A should be provided with Copper & procader terminals. Incomer of Meter Board shall have a minimum short circuit breaking capacity (Ics) of 25KA for one second at 415volt. 448 ELECTRICAL PANEL 449 INCOMING 450 1 No. 125 Amp FP Moulded Case Circuit Breaker. 451 1 Set of phase indicating lamps with MCB. 452 1 Set of ON/OFF indicating lamps with MCB. 453 1 No. Digital MFM with CTs. 454 BUSBAR 455 150 Amp TPNaluminium busbar with coloured heat shrinkable sleeve. 456 OUTGOING 457 9 Nos. 40 / 63 Amp TPN Miniature Circuit Breaker. 458 3 Nos. 25 / 40 Amp DP Miniature Circuit Breaker. 459 Panel described as above 460 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 461 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 462 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 463 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. 464 Providing and fixing 32 mm X 6 mm G.I. strip on surface or in recess for connections etc. as required. 465 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 466 Supplying following 1.1kV grade, heavy duty XLPE insulated PVC Sheathed Aluminum ConductorFRLS type armoured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete etc. as required. 467 3.5 core,50 sq.mm. 468 4 core,4 sq.mm. 469 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 470 Upto 35 sq. mm 471 Above 35 sq. mm and upto 95 sq. mm 472 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 473 3½ X 50 sq. mm (35mm) 474 4 X 10 sq. mm (25mm) (Also Used for 4 X 6 sq.mm) 475 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia 476 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness 477 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness 478 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness 479 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line : 480 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 481 Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 482 Extra for depth beyond 45 cm of brick masonry chamberFor 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 483 Extra for depth beyond 45 cm of brick masonry chamberFor 600x850 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 484 SITC ofIn-Ground 3000K, 4000K, 5700K 240Vac CRI >80 MacAdam step 3 Input power : 9W led DimensionØ173 x 220 mm Beam Angle : 40° (Tiltable 20°) Electronic driver ON/OFF CE and BIS, IP rating IP67 Die-Cast aluminium alloy housing (grade ADC12 with test certificate). 316 grade stainless steel front ring. Silicone seal gasket. SS fasteners. Mechanical resistance IK09. Pure polyester powder coated process : Acid treatment & pure polyester powder coating. ABS plastic installation housing for preparing the recess opening in ground. The luminaire are fixed in recess installation housing by stainless steel screws. Clear toughened glass diffuser with controlled upward light emission. Lamp fixed position This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire > 60,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >80%, power factor >0.90, THD <15%, Surge protection 2KV.Inhouse NABL accredited lab.Make :- K-Lite /Ligman/ Unilamp 485 SITC ofInput power : 18W,surface mounted compact spot light designed to provide directional light. Beam angle 15° / 25° / 40°. Luminaire made of pressure die cast aluminium alloy of high corrosion resistance and non corrosive A2 stainless steel fasteners. Clear toughened glass of 4mm thickness. Hybrid optics with lens & mirror finish pure aluminium reflector combination for higher efficiency, lower optical losses with optimum glare suppression. Swivel range of 0° - 90°. Single cable entrance M10 cable gland. Protection class IP66. Mechanical resistance IK06. Pure polyester powder coated graphite grey / anthracite grey / jet black. Available colour temperature 3000K / 4000K, Colour rendering index (CRI)>80. SDCM-3 MacAdam. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Luminaire dimension : 160mm length x 100mm width x 154mm height. CE & BIS Certified. Inhouse NABL accredited lab Make :- K-Lite /Ligman/ Unilamp 486 SITC of Flexible LED Strip 3000K, 4000K, 6000K24Vdc CRI >80 MacAdam step 3 Input power : 12W led Dimension1000 x 12 mm Beam angle : 120° Electronic driver ON/OFF (External driver) CE and BIS, IP rating IP67. Copper coated flexible strip, Silicone moulded diffuser, End cap . Silicone moulded diffuser This luminaire contains built-in LED modules. LED modules are engineered accordingly to the existing regulations of Lumen Maintenance (LM80) and Technical Memorandum (TM21), Lifespan of the luminaire >10,000 hours at 40°C. Operating ambient temperature range is from -15°C to +50°C. Driver efficiency >85%, Surge protection 3KV.Inhouse NABL accredited lab. Make :- K-Lite /Ligman/ Unilamp 487 FEEDER PILLAR(OUTDOOR TYPE) 488 Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of cubicle type totally enclosed free standing type moisture, dust, vermin & weather proofFloor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thickCRCA sheet complete with followingequipments, includingdigital ammeter with inbuilt ammeter selector switch, digital voltmeter with inbuilt voltmeter selector switch, indicating lamps, CTs, internal wiring with suitablesize wires / cable, MS Angle stand for installation, RCC foundation, interconnection, painting complete as per specification & drawing. 489 INCOMING 490 1 No. 40 Amp FP Moulded Case Circuit Breaker. 491 1 No. 0 to 500 Volt digital voltmeter with inbuilt selector switch. 492 1 No. 40 Amp digital ammeter with inbuilt selector switch and CTs. 493 1 Set of phase indicating lamps with Single Pole MCB. 494 1 Set of ON / OFFindicating lamps with Single Pole MCB. 495 BUS BARS 496 100 Amp TPNaluminium busbar. 497 OUTGOING 498 1 Set 24 Hrs TSQ Timer 499 1 Set 40 Amp, TP Contactor & A/M switch and Push Button. 500 8 Nos. 20 Amp TP MCB, 10 KA breaking capacity. 501 Panel described as above 502 Supply, Installation, Testing & Commissioning of Cat 6A, 23 AWG (0.57 ? 0.03mm ) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C.2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tapeor Metallic Shield inside. Connectivity of Hub room to End Point. Approved Makes:Derwiser/Nexans/Siemon/Systimax 503 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), Universal 110 Impact Tool & Tooless (Both) Termination, Min. 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fiat user end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 504 Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end. Approved Makes:Derwiser/Nexans/Siemon/Systimax 505 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 506 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,2 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 507 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone-Type Shuttered Faceplates for I/O fixing at user side.Approved Makes:Derwiser/Nexans/Siemon/Systimax 508 Supply, Installation, Testing & Commissioning of 15Uwall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. Approved Makes: Derwiser/MTS/Rittal/APC/APW 509 Supply, Installation, Testing & Commissioning of Cat 6A, 23 AWG (0.57 ? 0.03mm ) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C.2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tapeor Metallic Shield inside. Connectivity of Hub room to End Point. Approved Makes:Derwiser/Nexans/Siemon/Systimax 510 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack, ISO/IEC 11801:2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C.2 Category 6A, IEC 60603-7 (603-7), Universal 110 Impact Tool & Tooless (Both) Termination, Min. 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for camera at user end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 511 Supply, Installation, Testing & Commissioning of loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, UL-94V-0, clear label marks and earthing plug for CAT6A cable termination at rack end.Approved Makes:Derwiser/Nexans/Siemon/Systimax 512 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,1 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 1 Mtr for rack side switch to jack panel connectivity. Approved Makes:Derwiser/Nexans/Siemon/Systimax 513 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 6.2mm,2 Meter, Operating Temperature -20 to +60 Deg C. Patch cord 2 Mtr for rack side switch to end user connectivity.Approved Makes:Derwiser/Nexans/Siemon/Systimax 514 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone-Type Shuttered Faceplates for I/O fixing at user side.Approved Makes:Derwiser/Nexans/Siemon/Systimax 515 Supply, Installation, Testing & Commissioning of L2+ managed industrial PoE fiber switch with 24*10/100/1000M RJ45 ports and 4*1//10G SFP slot ports, Port 1-24 can support IEEE802.3af/at PoE.Switching capaticy of128Gbps, forwarding Rate 95.23 Mpps, having24 x 10/100/1000BASE-T PoE-plus(RJ45) with maximum PoE output power is 400W, 1 RS232 Console port.32K MAC address. Should have Static Routing ,system logging, Telnet, SSH, SNMP, Network Time Protocol (NTP),and IPv6 features from day 1, Security Feature: Port Isolation, VLAN, MAC, Spanning tree, Multicast, DDM, ACL, QoS: 802.1p (COS), DSCP, SP, WRR, Classification based on source IP, destination IP, and port number etc.Approved Make :Cisco/ Impulse / Juniper / Nexxus 516 Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5 SATA 6Gb/s Hard Drive; Operating system: Windows 10 Professional 64 Bit or latest.Approved Makes: HP / DELL / IBM / LENOVO 517 Supply, Installation, Testing & Commissioning of 8TB Surviellance Hard Disk. Approved Makes: WD /segate /Toshiba/HP 518 Supply, Installation, Testing and Commissioning of Full HD 55 LED Professional Display Panel.Approved Makes: Panasonic / LG/ Sony/ Samsung 519 Supply, Installation, Testing & Commissioning of Pure IP at core server Based voice solution with04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility ,28 IP users License ,01 Nos. IP Operator Console, 100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, TEC should be with GR Number, - Should Support Redundant server in active-Active mode.Approved Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix 520 Supply, Installation, Testing & Commissioning of Type 1 IP Phone 1 VoIP account , Full duplex speaker phone, IPV6, 2xLAN, PoE .Approved Makes: Tadiran/Arista /Polycom/Toshiba/ Aeonix 521 Supply, Installation, Testing & Commissioning of 24 Port PoE Access Switches with switching capaticy of 300 Gbps, forwarding performance 240 Mpps, having 24 x 10/100/1000BASE-T PoE-plus(RJ45) with minimum PoE budget of 720W and 4x 10G SFP+ uplink ports . Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address, 8K Multicast Routes, Should have static Routes from day 1.Approved make - Cisco / Juniper /Impulse / Nexxus/Arista 522 Supply, installation, testing and commissioning of 5 MP Bulletcamera ,ONVIF profile S ,G & T . UL , CE , FCC Certified ,1/2.7” Progressive Scan CMOS , 3.6 mm fixed lens , Quad stream support,min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter speed : Shutter speed :1 / 5s ~ 1 / 100,000 s ,WDR , Compression : H.265/H.265+/H.264/H.264+ .SD card support up to 256GB, frame rate : Main stream should support 25 fps@5MP , Edge analytics : Customer Flow staistics,Cross Count Heat Map, Human & Vehicle Detection, Pedestrian Intrusion Detection & Line cross Detection. Queue length detection, Regional population statistics, SOD-Stationaary Object Detection. , In built IR LED , IR Distance upto 30 meters , IP 66 , POE. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ Axis 523 Supply, installation, testing and commissioning of32 channel NVR , ONVIF compliant , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out : 16chin / 4chout , 1 X RJ45 ethernet , iOS smartphone support , 8 HDD support, each HDD slot support upto 8 TB HDD , 1x3.0 USBfor backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR .Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000,A.I maximum captured quantity200,000. UL,CE,FCC certified. Approved Makes : Allgovision/ Impulse / Avigilon / Cisco/ Axis 524 GST Extra as applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
41.
Housing Urban and Rular Development #9440573 Technical Bid
Tender For Beautification Work At Pt. Deen Dayal Upadhyay Park And Tourist Infrastructure Development Of Chaura Mata Temple At District-Jaunpur., 1 Civil Work (Multipurpose Hall, Toilet Block, Kiosk, Shelter, Mural, Boundary Wall, Gate, Ornamental Stambh, Statue Platform, Stone Pathway, OAT, Interlocking/Grass Paver Block, Boulder Pitching) 2 Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 3 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 4 Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. 5 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 6 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos E.C. 20% with 1% concentration 7 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration 8 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 9 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 10 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for massconcrete 11 Suspended floors, roofs, landings, balconies and accessplatform 12 Lintels, beams, plinth beams, girders, bressumers andcantilevers 13 Columns, Pillars, Piers, Abutments, Posts and Struts 14 Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 15 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 16 Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) 17 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 18 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement :4 coarse sand) 19 Cement mortar 1:4 (1 cement :4 coarse sand) 20 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 21 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 22 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 20 mm nominal size) 23 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part |!) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Single Leaf 24 Double Leaf [ Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). ] 25 Both side laminated 26 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.50 mm thick 27 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.Providing & fixing of hold fast for chaukhatsof doors and windows. 28 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (Zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). 29 Float glass panes.4 mm thick glass pane (weight not less than 10kg/sqm). 30 Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading 31 Providing and fixing ISI marked S.S. sliding door bolts with nuts and screws etc. complete : (a) 250mm x 16mm. 32 Providing and fixing ISI marked S.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (a) 250 mm x 10mm 33 Providing and fixing ISI marked S.S. handles conforming to IS:4992 with necessary screws etc. complete : (a) 125Mm 34 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 35 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. 36 15mm thick plaster with cement mortar in proportion of 1:6 cement & coarse sand of 2.25 F.M. (1) 1 cement : 6 coarse sand 37 12mm thick plaster with cement mortar in proportion of 1:6 cement & coarse sand of 2.25 F.M. (1) 1 cement : 6 coarse sand 38 Making groove 10 to 12 mm wide x 8 mm deep in plaster of the wall or in ceiling vertically or horizontally as required. 39 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including waterthinnable priming coat with cement primer 40 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 41 Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 42 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 43 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cementmortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 44 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 45 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm 47 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm 48 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 49 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing .40mm thick 50 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 51 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 52 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Red sand stone 53 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc.Red sand stone 54 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 55 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derivedfrom natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 56 Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Using R4 series with frame (64 mm & above) x (50 mm & above) & sash (64 mm & above) x (70 mm & above) & mullion (64 mm & above) x (70 mm & above). (Height above 1.8 metre; each openable shutter upto 0.8m width) 57 Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of Engineer-in-charge. 58 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 59 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. 60 Providing and fixing ISI marked oxidised M.S. Sliding door bolts with nuts and screws etc. complete (a) 300 mm x 16mm 61 Providing and fixing ISI marked oxidised M.S. Tower bolts black finish, (Barrel Type) with necessaryscrews etc. complete (a) 250 mm x 10mm 62 Providing and fixing ISI marked oxidised M.S. handles conforming to IS 4992 with necessary screws etc. complete.125mm 63 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 64 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 65 Painting Steel work with Deluxe Multi Surface Paint to give aneven shade. Two or more coat applied @ 0.90 ltr/10 sqm overan under coat of primer applied @ 0.80 ltr/10 sqm of approvedbrand and manufacture 66 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) 67 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 68 Stone work plain ashlar in arches in super structure upto floor V level in cement mortar 1:3 (1 cement : 3 coarse sand) including centering, shuttering and pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 69 Supplying, designing, fabricating, transporting, hoisting and fixing in position mural works in good quality of 70 mm Red sandstone, and 18mm marble insertion and 6-10mm powder coated MS sheet in various elements for all levels. Stone shall be free from cracks, lines stains and even in shade for each element. The stone shall be fine grained and reddish or buff-colored (locally available). The work shall be carried out as per attached drawings with different process of i.e carving (manual/ by machine), ornamental work, traditional work, figure work (any type, any size), CNC cutting, moulding, etching, buffing and polishing. The carving and molding work shall be of very good quality. The work to be fixed in line, level and plumb in all respect with the use of brass clamps, pins, (to be paid separetely) dowels, cement slurry with matching pigment and Epoxy of Akemi Germany, Ardex Endura, MYK laticrete or approved make as required and as approved by the Architect in charge. 70 Supplying, fabricating, transporting, hoisting and fixing in position good quality of Ornamental Brass Matki Sculpture in various elements for all levels, inlcuding the cost of oranmental work and mouldings, carvings as required, of varied thickness shall be used for stacking. Also includes the cost of structural load calculation and design with respect to the drawing recevied from architect in charge. Preferable tentative size 0.75MX0.75MX0.85M OR tentative Size as approved from architect in charge 71 Providing & fixing Cobble Stone Flooring (10X10X10)cm filling of joints in 1:3 Cement mortarwith matching colour pigments all complete specification & direction of Engineer in charge. 72 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 73 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. 74 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 75 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil 76 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick Jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. 77 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 78 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete. 79 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Red sand stone flooring 80 Supply and fixing rolling shutter of approved make and of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially design pipe shaft with brackets side guides and arrangement for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire spring manufactured from high tensile steel wire of adequate strength confirming to IS 4454 part-1 and M.S. top covered of required thickness for rolling shutter 80x1.25mm. 81 Providing, fixing wall bearing for rolling shutters. 82 Plumbing and Sanitary Work 83 Providing and fixing white vitreous chinaextended wall mounting type water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china cistern with dual flush fittings of flushing capacity 3 litre / 6 litre ( adjustable to 4 litre / 8 litres ) includung seat cover & cistern fittings nuts , bolts and gaskets etc complete. 84 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25 mm nominal bore 85 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :For vertical pipe connection with terrace ringmain 25mm nominal bore 86 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 87 Providing & fixing toilet paper holderC.P. brass 88 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 89 Providing and fixing Jaquar Make Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook of quality and make as approved by Engineer - in - charge. 90 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm witha single 15 mm C.P. brass pillar tap 91 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 92 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 93 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 94 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 95 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 (including angle valve for WC flushing cistern & jet) 15 mm nominal bore 96 Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore 97 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 100 mm diameter 98 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore 99 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width78 mm and effective height of 88 mm, weighing not lessthan 190 gms. 100 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. 101 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15mm nominal bore 102 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore 103 Providing and fixing C.P. Brass extension nipple (size 15 mm x 50 mm) of approved make and quality as per direction of Engineer-in-charge. 104 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Including C.I. trap for standard urinal with vent arm with operating and other couplings in C.P.brass: 50 mm dia) 105 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as perdirection of Engineer-in-charge and finished smooth.Granite Stone of approved shade 106 Providing and fixing of Kent Elite Plus Water Purifier (RO+UV+UF+TDS Control) with flow rate (50L/hr)including all its accessories, complete in all respect including testing etc. 107 Providing and fixing of Water Cooler (Voltas Make) including all its accessories, complete in all respect including testing etc. 108 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.For Internal Toilet15 mm nominal outer dia Pipes 109 20 mm nominal outer dia Pipes 110 25 mm nominal outer dia Pipes 111 32 mm nominal outer dia Pipes 112 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall32 mm nominal bore 113 Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall Terrace loop & Tank Filling Pipe 40 mm nominal bore 114 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 40mm diameter pipe 115 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40mm diameter pipe 116 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : For vertical pipe connection with terrace ringmain 32mm nominal bore 117 40mm nominal bore 118 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore 119 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./H.P.H.D. plastic ball. 40 mm nominal bore, 206 mm long, weighing not less than 690 gms 120 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 121 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm dia (for rain water) 122 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. Single Push Fit Coupler 110 mm dia 123 Single tee with door 110x110x110 mm 124 Plain bend 87.5 deg 110 mm dia 125 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm dia 126 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 127 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 128 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 100mm dia SWpipe 129 Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes Internal Toilet (Soil & Waste Pipe). 75 mm 130 110 mm 131 Exposed on Wall (Soil & Waste Pipe) 110 mm 132 Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. Bend without door (45°) 75mm 133 110mm 134 Bend without door (87.5°) 75mm bend 135 110mm 136 Y Fitting without door 75mm 137 110mm 138 Single Tee without door 75mm 139 110 mm 140 Single Tee with door 75mm 141 110 mm 142 Bend with door (87.5°) 75mm 143 110 mm 144 Clean Out Plug (COP) 75mm 145 110 mm 146 Reduced Y Fitting without door 110mm x 75mm 147 Reduced Tee with door 110mm x 75mm 148 Coupler 75mm 149 110mm 150 Vent Cowl 110mm 151 Providing, fixing, jointing and testing, unplasticized PVC pipes - 10 kg/cm2 confirming to IS : 4985 to wall, ceiling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Urinal 32mm dia. Pipe 152 50mm dia. pipe 153 Elbow (45°) 32mm 154 50mm 155 Elbow (90°) 32mm 156 50mm 157 T fitting 32mm 158 50mm 159 Coupler 32mm 160 50mm 161 Providing, fixing, jointing and testing ,ofPVC Multi Floor Trap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 110mm x 75mm x 50mm/40mm (Toilet) 162 Providing, fixing, jointing and testing , ofPVC NahaniTrap without jali ofminimum 50 mm water seal, making necessarycuttingin slabor floors and making goodincluding supports with cement concrete 1:3:6complete as approved by Engineer-in-Charge. 110mm x 75mm (Toilet & Kitchen) 163 Providing and fixing PTMT grating of approved quality and colour. Rectangular type with openable circular lid 150 mm nominal size square 100 mm diameter of the inner hinged round grating (including balcony) 164 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100mm size P-typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 165 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm diameter 166 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. All kind of soil Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. 167 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standard design: 100mm dia SWpipe 168 Fire Fighting Work 169 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. (EXTERNAL WORKS) 100 mm dia. 170 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia. 171 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. 172 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904as required :2 way - 100 mm dia M.S. Pipe (Siamese Connection) 173 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in allrespects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head 174 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (for terrace booster pump) 175 Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) 176 Providing and fixing in position the industrial type pressuregauges with gun metal / brass valves complete as required (for terrace booster pump) 177 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. 178 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. 179 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm nominal bore 180 100 mm nominal bore 181 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal 182 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m 183 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun metal 184 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal 185 Providingandfixing standard fire mans axe with heavy duty insulated rubber handle. 186 Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge.(Approx. size of door:900mm Wide & 1500mm Height) 187 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 188 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 189 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 190 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 191 Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. 192 FIRE FIGHTING PANEL 193 Fabricating & Supply, installing, testing and commissioning ofsheet steel clad floor mounting control panel having suitable size for control of 1 nos. booster pumps 9.3 KW/12.5HP each having suitable incoming MCCB, incoming voltmeter with selector switch and fuses. Star delta starter with hand reset overload cum single phase preventor type relay, Ammeters to read current in any one phase, alarm with reset push button which will automatically reset for the next cycle.(As per the Technical Specifications)(At Terrace floor) 194 Supply, installation , testing & commissioning of XLPE insulated and PVC outer sheathed Aluminium conductor armoured cable of 1.1 KV grade confirming to IS : 7098:1988 (with upto date amendments) of following sizes. 3 Core, X 6 sqmm. 195 Supplying and making end termination with brass compression gland & Al.lugs for following sizes of PVC insulated, PVC sheathed/ XLPE Al.conductor cables of 1.1 KV grade as required. 3 Core, X 6 sqmm. 196 Supplying and laying control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathedarmoured cable between various sensors and system controller/starter etc.in pump house & out side on surface/existing cable tray complete with connections at both end with glands etc.as required 2 x 2.5 sq.mm 197 Supplying and installing following size of perforated pre-painted M.S.cabletrayswithperforationnotmorethan17.5%,in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness. 198 Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. 199 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. 200 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 201 Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. 202 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete asrequired. 203 Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. 204 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 205 Internal Electrical Work 206 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group - C 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 208 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 209 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 210 4 x 10 sq.mm + 2 x 6 sq.mm. earth wire 211 4 x 16 sq.mm + 2 x 6sq.mm. earth wire 212 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 amps modular switch, connection etc. as required. 213 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 214 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 215 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required 216 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 217 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 218 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/ M.S. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. Clamp shallbe made of 12 mm dia M.S. bar bent to shape as per standard drawing. 219 Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) 220 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep 221 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 222 Supply of LED 4ft Batten with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 25,000 burning hours at L70. The luminaire should have a color temperature of 4000K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.9. The luminaire housing should made of extrusion Al with a PCdiffuser. The total power consumption should not exceed 21W (including driver).Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 223 Supply of Surface mounting round 6 Watt 10 Watt , LED Down Lighter, suitable for 24Hr Continuous Operation, 660-1100 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 224 Supplying of LED mirror light luminaire with 10Wwatt complete with electronic ballast, lamp including connection etc. complete as required, Including connection with 1.5 sqmm FRLS PVC insulated copper conductor. 225 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep ceiling fan 226 Supplying, erection, connecting, testing and commissioning of 600 mm Wall Fancomplete in all respect. 227 Supplying of following size exhaust fan complete with gravity louver and connection with 3 core flexible wire as required.300mm EXHAUST FAN 228 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 63 A,25KA,FP MCCB 229 100 A,30KA,FPMCCB 230 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 Way Double door 231 6 way Double door 232 Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required.(Note : Vertical type MCB TP DB is normally used where 3 phase outlet are required.) 4 way (4 + 12), Double door 233 Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 amps TP MCB 234 63 amps TP MCB 235 40 amps 4P MCB 236 63 amps 4P MCB 237 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 238 Double pole 239 Triple pole 240 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 241 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 242 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 243 Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required. 244 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 245 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 246 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 247 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle 248 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle) 249 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment 4 x 25 sq.mm 250 4 x 16 sq.mm 251 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 2 X 6 sq. mm (19mm) 252 4 X 16 sq. mm (28mm) 253 Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required 100 mm dia 254 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100mm dia 255 Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) includingexcavation and refilling the trench but excluding sand cushioningand protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 256 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness. 257 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm wide x 50 mm depth x 1.6 mm thickness. 258 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Way Double Door 259 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm. 260 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment3 x 6 sq.mm, 261 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 2 X 6 sq. mm (19mm) 262 Providing, laying and fixing following dia G.I. pipe (mediumclass) in ground complete with G.I. fittings including trenching(75 cm deep)and re-filling etc as required 100 mm dia 263 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way Double Door 264 Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V C curve DP MCB complete withconnections, testing and commissioning etc. as required. 265 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 2 X 16 sq. mm (22mm) 266 Supply of surface mounting 2x2 feet 24 to 30W LED , suitable for 24Hr Continuous Operation, 3000-6000 system lumens, 110lm/W,PF>0.95, THD <10% at full load, CRI>80, Avg Life Class 50000Hrs @L70,complete in all respect. 267 Supply and fixing of 9 Watt LED Inground UpLight luminaire Confirming to IP 66 Protection complete in all respect. 268 Supplying and fixing following way ,single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Way Double Door 269 Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V C curve DP MCB complete withconnections, testing and commissioning etc. as required. 270 Tubewell 271 Drilling of 200 mm dia bore hole. 272 Supply of 125 mm dia MSpipe as per IS1239 273 Supply of 125 mm dia slotted MSpipe 274 Supply and fixing of nylon jali around the slotted pipes complete as required. 275 Providing and packing of coarse sand / pea gravel around the pipe (7.44 Cum) 276 Transport of boring tools other required equipements and installation at site. 277 Supply of submersible pump of make KSB (Cora) for 200 lit/min discharge at 50 meter head with control panel, support wire etc complete. 278 Providing/inst. Of copper multistand PVC insulated FR cable suitable for submersible pump. (from Starter panel to submersible pump)3 core copper cable 279 Providing and fixing 65 mm dia. G.I. pipe complete with fittings and clamps including cutting and making good the wall etc. (from submersible pump to ground level) 280 Providing and fixing 65 mm dia. brass gate valve with CI wheel of approved quality. 281 Lowering of 125 mm dia MS pipe in bore hole including cutting,jointing etc complete. 282 Supply and fixing of tube well accessories i.e. well cap, clips, clamps, etc. to complete the job in all respect. 283 Fixing, testing and commissioning for erection and lowering of submersible pump, 65 mm dia GI column pipe, 3 coresubmersible copper cable upto the control panel, supporting clamps, cable clips, pressure gauge, connection line and all other accessories required for the proper completion of the work 284 Testing and development of tube well. 285 External Sewerage works 286 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. up to 1.50 m depth Pipes 80 mm to 300 mmdiameter 287 1.50 m to 3.00 m depth Pipes 80 mm to 300 mmdiameter 288 Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) Depth not exceeding 1.5 meter 289 Depth 1.5 to3.00meter 290 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.150 mm.dia. RCCPipes 291 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm.dia. RCCPipes 292 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 293 Extra for depth for manholes:Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 294 Inside size 90x120cms and 90cms deep including CI cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg). With common burnt clay FPS (non modular) bricks of class designation 75 (i) For Sewer Line 295 Extra for depth for manholes:Size 90x120cm with With common burnt clay FPS (non modular) bricks of class designation 7.5 296 Providing orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 297 External water Supply System 298 Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work) 65mm nominal bore. 299 50mm nominal bore. 300 40mm nominal bore. 301 32mm nominal bore. 302 25mm nominal bore. 303 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65mm nominal bore. 304 50mm nominal bore. 305 40mm nominal bore. 306 32mm nominal bore. 307 25mm nominal bore. 308 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (horizontal) 65mm nominal bore. 309 50mm nominal bore. 310 40mm nominal bore. 311 32mm nominal bore. 312 25mm nominal bore. 313 Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 314 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 315 Development of Drain 316 Excavating trenches by mechinical / manual means of required width for pipes cables etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed , within a lead of 50 m. up to 1.50 m depth Pipes 80 mm to 300 mmdiameter 317 Providing and laying NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.150 mm.dia. RCCPipes 318 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. 319 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick,finished with a floating coat of neat cement complete as per standard design : 320 Constructing brick masonary open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: Drain 300 wide average.Depth 45 cm with R.C.C. slab 321 Drain 450 wide average.Depth 60 cm with R.C.C. slab 322 Development of S.T.P. 323 Supplying, designing, Package Type Sewage Treatment Plant of capacity 25 KLD make as required and as approved by the Architect in charge. 324 Installation Charges 325 Landscaping & Horticulture works 326 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 327 Supplying and stacking of good earth at site including royalty but including carriage1km (earth measusred in stacks will be reduced by 20% for payment). 328 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm 329 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 330 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately). 331 Rough dressing the trenched ground including breaking the clods. 332 Fine dressing the ground 333 Grassing with selection No.1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and the good earth shall be paid for separately). 334 Uprooting weeds from the trenched area after 10 to 15 days after flooding with water including disposal of uprooted vegetation. 335 Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge 336 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 90 cm dia, and 90 cm deep 337 Preparation of beds for hedging and shrubbery by excavating 60 cmdeep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). 338 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water) 339 Providing and stacking of Acacia auriculiformis of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 340 Providing and stacking of Adansonia digitata (kalp vricksh) of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. 341 Providing and stacking of Bombax ceiba of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 342 Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge 343 Providing and stacking of Fishtail palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 344 Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35 - 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. 345 Providing and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur)of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 346 Providing and stacking of Pinus longifolia (Pinus) of height 90-105 cm. in cement pots of size 35 cm as per direction of the officer-in-charge. 347 Providing and stacking of Butea frondosa (Flame of Forest) of height 60-75 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 348 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 349 Providing and stacking of Ficus benjamina (green) of height 120-135 cm. with 6-8 branches and lush green foliage in g. bags of size 25 cm as per direction of the officer-in-charge. 350 Providing and stacking of Ficus panda of height 90-105 cm. with 10-12 branches and healthy foliage, well formed in cement pots of size 30 cm as per direction of the officer-in-charge.. 351 Supply and stacking of Plumeria alba plant of height 120-135 cm. with 2-3 branches in bags of size 30 cm as per direction of the officer-in-charge. 352 Supply and stacking of Plumeria rubra plant of height 120-150 cm. with 3- 4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge 353 Supply and stacking of Tabebuia sp. plant of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 354 Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge 355 Supply and stacking of Cassia fistula (Amaltash) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 356 Supply and stacking of Michelia champa (Golden Champa)plant of height 90-105 cm. in earthen pots of size 25 cm as per direction of the officer-incharge. 357 Supply and stacking of Peltophorum species plant of height 150-165 cm in big poly bags of size 25 cm as per direction of the officer-in-charge. 358 Supply and stacking of Lagerstroemia thorelli plant of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 359 Supply and stacking of Mimusops elengi (Maulsri) plant of height 180-195 cm. well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. 360 Providing and stacking of Ficus bengalensis (Bargad) of height 120-135cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 361 External Lighting 362 MAIN PANEL Supply & Erection of factory fabricated & wired metal clad dust and vermin proof mounting, M.S Channel Base with botom and top cable entreis Electrical control panel with TPN ACB (65KA, 4 Pole Elect draw out Micor Processer Release IPR2) and TPN MCCBs (four Pole 36 KA with thermal magnatic release) switches and instrument chamber etc. complete in all respect. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter, Selector switches for ammeter and Voltmeter, instrument fuses current transformer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. The switches enty boxes shall be complete with suitable cable end boxes reverse. The job includes the grounting of the board as per directions of Engineer-in-charge. All out goings of 100 Amp. and above will be provided with Amp. Metre, curent transformer and selector switches etc. and insurment fuse The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubical type switch board shall be of cat A & B only. 363 FEEDER PILLAR-2 INCOMING 1No. Of 40 Amps FP MCCB of 35KA breaking capacity Metering : 1 Set of CTs one of 63/ 5Amp ratio for Multifunction Meter One (1) Set of Phase Indication Lamp. 364 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each 365 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 366 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. 367 Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required. 368 Laying of one number PVC insulated and PVC sheathed / XLPE powerCable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm. 369 Above 35 sq.mm. and up to 95 sq.mm. 370 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Up to 35 sq.mm. 371 Above 35 sq.mm. and up to 95 sq.mm. 372 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle 373 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp 374 Supply of following siz of 1.1KV grade multicorealuminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment3.5 x 50 sq.mm 375 3 x 6 sq.mm, 376 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 2 X 6 sq. mm (19mm) 377 3½ X 50 sq. mm (35mm) 378 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100mm dia 379 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal) 380 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks ofclass designation 7.5 381 SITC of 15w integrated Solar All in one suitable at height of 5mtr mounting arrangement. pole with minimum 2250 lumen , luminous flux with min.>150lm/w luminous efficacy having power of PV module (Wp) 40, Panel Type Mono Crystalline, Panel Dimensions not more than (mm) 775 (L) x 340 (W) x 60 (H), Battery Capacity max. 18 (Ah), Battery Rated Voltage 12.8(V), Battery type LiFePO4, having BMS protection Battery Management System ,having min. Battery Back up to 2days (24 hours) (Autonomy mode),MPPT charge controller type, Efficacy>90%, having facility of Charging Indicator (Green blinking),Low Battery Indicator (Red blinking),Error Indicator (Both blinking),For the better battery life having Over Charge Protection, Deep Discharge Protection, Battery reverse polarity protection ,Load Short circuit protection, Load Open circuit protection, Reverse polarity protection for Panel, Over temperature protection. Motion sensor detection facility with Long Distance Detection 12m.CCT-5500-6000k, Make-Panasonic, Philips or equivalent 382 POLE LIGHTS Supply ,Installation ,Testing And Commissining OfTwinkle Lites Make 3000Mm Long Hybrid Decorative Pole With CastedAluminium Base And Ripped Gi Pole PipeWith Decorative Post Top Lantern Concord 1270Mm Long With Polycarbonate Diffuser In 60W Led Having Lumn Output Not Less Than 110Lmns/Watt With 10Kva Surge Prtector Designed As Per Architect In-Charge( Make- Twinkle Lite-/-Havells/Neri/Juvaas/Orient/ Thor) 383 Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver andapable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 40 W 384 Garden Light Bollards:TWINKLE LITE - Urban Garden LED Bollard made out of extruded aluminum pro?le withcast alumn. base and PC/PMMA diffuser for uniform light distribution with PC covers.Twinkle Lite-818 (BL-E27) [ 27 Watt ] 385 Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 1 output per phase and suitable for single phase supply 386 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required 32 mm dia 387 Development of Pond 388 Clearance of a water body, whether its a pond, lake, or reservoir, involves several critical steps to ensure the water is clean, safe, and aesthetically pleasing. Heres a detailed specification for the clearance process, including chemical dosing for algae clearance, removal of heavy particles and unwanted vegetation, dewatering, sludge accumulation and disposal, and refilling with clean water if necessary.1. Chemical Dosing for Algae Clearance:1.1. Initial Assessment: Before chemical dosing, conduct a thorough assessment of the water body to determine the type and extent of algae infestation. Identify the species of algae, if possible, as different species may require specific treatment.1.2. Chemical Selection: Choose appropriate algaecides or chemicals based on the assessment. Ensure that the selected chemicals are safe for aquatic life, and their application complies with local environmental regulations.1.3. Dosage Calculation: Calculate the required dosage of the chosen chemical based on the volume and depth of the water body, as well as the severity of the algae infestation. Use the manufacturers recommendations as a guideline.1.4. Application: Disperse the calculated amount of algaecide evenly across the water surface. Depending on the chemical, you may need to dilute it with water before application. 2. Removal of Heavy Particles and Unwanted Vegetation:2.1. Initial Assessment: Identify areas with heavy particles and unwanted vegetation, such as floating debris, branches, and overgrown aquatic plants. 2.2. Handpicking and Netting: Deploy trained personnel to manually remove heavy particles and unwanted vegetation. Use nets, rakes, or other appropriate tools to efficiently remove debris and vegetation.2.3. Disposal: Properly dispose of collected debris and vegetation in an environmentally responsible manner. Consider composting organic material and disposing of non-organic waste in accordance with local regulations. 5. Refilling with Clean Water (if required):5.1. Water Quality Testing: Before refilling, conduct water quality testing to ensure that the water meets safety and quality standards. Ensure that it is free from contaminants, including residual algaecides.5.2. Clean Water Source: Use a clean and reliable water source for refilling the water body. This may involve sourcing water from another clean body of water or treating municipal water to meet quality standards.5.3. Gradual Refilling: Refill the water body gradually to minimize temperature and water chemistry shocks to aquatic life. Monitor water parameters during the refilling process to maintain optimal conditions.5.4. Post-Refill Monitoring: After refilling, continue to monitor water quality regularly to ensure it remains clear and healthy.Ensure that all personnel involved in the clearance process are properly trained, and the entire process complies with local, state, and federal regulations regarding water bodies and environmental protection. Periodic maintenance and monitoring should also be established to prevent future issues and maintain water body health 389 TOURIST FACILITIES & INFORMATION CENTRE 390 Resting Areas for Tourist (Benches) {MR} Stone Benches - Providing & fixing of red Sandstone/MS bench with Ornamentation (size 1500mm length and 450mm and height 600 mm) including foundation & support with all necessary T&P etc. all complete as per design of direction in engineer/ Architect in charge. 391 Urban Litter Bins(MR) Providing & fixing of SS Dustbin size 487 x 399 x 1138 fixing on a foundation with base plate and wrapped with red sandstone from all sides of 75mm with all complete as per design of direction in engineer/ Architect in charge. 392 Directional & Informative Signages (MR) Providing and fixing StandAlone Signage in Marble of approved thickness with powder coated 10-12mm MS letters and illustration at desired locations with letters (in english, hindi and Braille)- etched, through cut, infilled or painted, also including the cost of design, fabrication and onsite installation with all the necessary accessories and equipments for fixing on any surface as per drawing and design approved from Architect in chargeEnglish: Helvetica Font with min. 36 sizeHindi: Krutidev Fontwith min. 36 size Signage-A 393 Signage-C 394 Water Dispenser - Receiving, storing, handling, shifting, installation, testing & commissioning of Voltas water cooler, including all accessories complete in all respect etc. (Make - Voltas or Equivalent) 395 PA System 396 10W Horn Speaker weatherproof 397 50 W or better IP amplifier with housing with rack mounting kit suitable for outdoor rack mounting temp-0-50 degree 398 Master control desk with display, handset and desk kit 399 Central software with license including pre recorded message,reporting module for PA system 400 Supply , Installation, testing and commissioning of industrial grade layer 2 switch with 8 ports 10/100/1000 Mbps GE port with 2x1 Gbps SFP ports 401 Supply , Installation, testing and commissioning of 1G SFP Module 402 Supply , Installation, testing and commissioning of weatherproof rack pole/wall mounted 4/6 as per site req 403 Supply , Installation, testing and commissioning of 1G SFP+ Module 404 Supply of outdoor Cat-6 cable 405 Laying of Cat-6 406 Supply of 6C SMF armored OFC 407 Supply , Installation, testing and commissioning of 12 Port LIU fully loaded with all necessary accessories 408 Supply , Installation, testing and commissioning of SC/LC OFC patch cord 409 Supply of 3C 1.5 sqmm power cable 410 Supply of 5KVA online UPS with battery 411 Supply of Stabilizer 20KVA 412 Supply , Installation, testing and commissioning of Client Workstation, Processor- Intel i5 3.2 GHZm Memory- Minimum 32 GB Hard disks -500GB SSD at 7200 rpms OS- Windows 10, 64bit Network Card-1Gbit/s network card NVIDIA Graphic card of minimum 4 GB memory with 4K display 24 413 GST as per Applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
42.
Educational and Research Institute #9426408 Technical Bid
Rate Contract For The Procurement Of Consumables/Non-Consumables For The Department Of Transfusion Medicine , Note:1.*Samples For Kits, Reagents And Consumables Marked With Star (*)/Brochure Listing Product Details/Certificate Certifying Compliance To Specifications Should Be Provided To The Dept. Of Transfusion Medicine, Jipmer Within One Week Afterdisplay Of Successful Bidders In E- Tender. 2. #Samples For Kits, Reagents And Consumables Marked With Star (#), Distributor Authorization Letter From The Manufacturer Should Be Provided To The Dept. Of Transfusion Medicine, Jipmer Within One Week Afterdisplay Of Successful Bidders In E- Tender.3. In Case Of Non-Receipt Of Samplesas Specifed For Above Within One Week After Display Of E-Tender, An E-Mail Remainder (Mentioned In Tender Form) Will Be Sent To Supply The Same. In Case Of Non Receipt Of Sampleswithin One Week Of Reminder The Bidding Will Automatically Stands Canceled. Only Bidders Who Have Provides Samples Will Be Taken For Final Evaluation 4. Selection Will Be Made Only After Evaluation Of Samples/Brochure, Certificate/ Demonstration Etc.Consumables , Anti-A Grouping Sera Igm (Monoclonal)* (10 Ml Vials)Specifications For All Above Antiseras And Bovine Albumin (Item No: 1 To 13) 1. All Antiseras Should Meet Minimum Quality Control Specifications As Per Transfusion Medicine Technical Manual, 2Nd Edition, Pg.No: 346-351; Director General Health Services, Ministry Of Health And Family Welfare, Govt. Of India Publication2. The Manufacturers Should Have Supplied All Above Mentioned Antiseras And Bovine Albumin Continuously And Satisfactorily To Government Blood Banks For A Period Of 5 Years. List Of Such Government Blood Banks Should Be Enclosed. A Satisfactory Quality And Supply Certificate From Any Of The Two Government Blood Banks Should Be Enclosed For Preceeding 3 Years.3. The Quantity Quoted May Be Increased Or Decreased Without Assigning Any Reasons. , Anti-B Grouping Sera Igm (Monoclonal)* (10 Ml Vials) , Anti-Ab Grouping Sera Igm (Monoclonal)* (10 Ml Vials) , Anti-D Grouping Sera Igm (Monoclonal)* (10 Ml Vials) , Anti-A1 (Lectin)* (5 Ml Vials) , Anti-D Igm + Igg Grouping Sera (Monoclonal)* (10 Ml Vials) , Anti-D Igg Grouping Sera (Monoclonal)* (10 Ml Vials) , Anti -D Igg Grouping Sera (Polyclonal)* (5 Ml Vials) , Anti -H (Lectin)* (5 Ml Vials) , Bovine Albumin 22%* (5 Ml Vials) , Anti Human Globulin Sera Igg+C3d (Polyspecifc)* (5 Ml Vials) , Anti Human Globulin Sera Igg (Monospecific)* (10 Ml Vials) , Anti Human Globulin Sera C3d (Monospecific)* (10 Ml Vials) , Instant Abd Blood Grouping Pad/Cards/Strips For Voluntary Blood Donation Camps. (Ready To Use For Blood Grouping Anti-A, Anti-B And Anti-D Igm)* Specifications:1. The Above Pad/Cards/Strips Should Be Approved By Statutory Authority Like Drug Control General Of India/National Inst. Of Biologicals. 2. The Pad/Cards/Stripes Should Contain Wells With Precoated Monoclonal Antisera With Color Coading And Suitable Medium/Matrix To Immobilize Agglutinated Red Cells So As Results Are Read Witin 30-45 Seconds3. The Pad/Cards/Strips Can Be Used At An Ambient Temperature Of 20-40Deg C. 4. It Should Compatible With All Types Of Blood Samples, Namely Whole Blood, Heparin, Finger Prick, Blood Bag Segments Etc.,5. It Should Easily Readable For 24 Hours After Testing,Fully Traceable By Photography/Other Media. 6. Should Be Able To Detect Weak Abd Antigens7. Necessary Dispensing Micro Pipettes/Pasteur Pipettes And Tips Should Be Provided Along With The Kits. 8. Necessary Buffers And Other Consumables Should Be Provided In Enough Quantity Including Wastage If Any For Complete Usage Of All Cards/Pads/Stripes Along With The Kits. 9. The Bidder/Supplier Should Provide Satisfactory Certificates From 3 Blood Banks Which Are Already Using Such Pads/Stripes/Cards.10. Product Should Be Ce Marked11. Expiry After Opening Minimum 14 Days , Copper Sulphate Cuso 4.5H2o - Ar Grade* (500 Gms) , Polygrid Test Tube Stand (For 12 X 100Mm) - 48 Tubes , Stands For Blood Grouping Antisera , Round Adhesive Wound Plaster - Disposable* (100 Nos) , Round Blood Lancets - Disposable And Sterile* (100 Nos) , Disposable Pasteur Pipettes 1 Ml.(500 Nos) , Disposable Pasteur Pipettes 3 Ml.(500 Nos) , Disposable Pasteur Pipettes 10 Ml.(500 Nos) , Blotting Paper (White Ordinary) 60 X 60 Cm* (500 Nos) , Cryo Gloves - Water Proof, Mid Arm, Size-Medium , Tissue Roll* , K3 Edta- Non-Vacuum Tubes 2 Ml* (100 Nos) , K3 Edta- Vacutainer 2 Ml* (100 Nos) , Vacutainer Needle With Holder And With Needle Protector (100 Nos) , Microtip Boxes 2-20 ?L -Autoclavable , Microtip Boxes 2-200 ?L -Autoclavable , Microtip Boxes 200-1000 ?L -Autoclavable , Acrylic Beakers - 50 Ml , Acrylic Beakers - 100 Ml , Acrylic Beakers - 250 Ml , Acrylic Beakers - 500 Ml , Conical Flask - 50 Ml , Conical Flask - 100 Ml , Conical Flask - 250 Ml , Conical Flask - 500 Ml , Conical Flask - 1000 Ml , Thermal Paper For Elisa Reader 110 X 20 (11 Cms Width)* , Pipette Stand (For 6 Pipettes) , Reagent Bottle Stand , Blood Bag/Ffp Storage Racks , Teepol Liquid Cleaner* (10 Litres) , Sodium Hypochlorite Solution 4%* (5 Litres) , Isopropyl Alcohol (500 Ml) , Electronic Thermometer (Wettable)-Range Upto Minus 80 , Surface Temperature Measuring Thermometer , Magnetic Stirrer Bar , Specific Gravity Meter-With Range 1.000 To 1.100 , Nageottes Chamber , Volumetric Flask -500 Ml , Mortar & Pestle , Capillary Tubes (100 Nos) , Ulex Europeus For Lectin Preparation-1Mg , Dolichos Biflorus For Lectin Preparation (1 Mg) , Arachis Hypogea For Lectin Preparation (1 Mg) , Thrombin From Bovine Plasma - Lyophilized Powder (1 Ku) , Protamine Sulfate Reagent (5 Gms.) , Epsilon Amino Caproic Acid-Reagent Grade (1 Gm) , Sodium Dihydrogen Phosphate-Reagent Grade (500 Gms.) , Disodium Hydrogen Phosphate -Reagent Grade (500 Gms.) , Bovine Albumin 6%-Reagent Grade (100 Ml) , Papain Powder-Reagent Grade (100 Gms.) , Ficin Powder-Reagent Grade (100 Gms.) , Phosphate Buffer Saline - Ph 7.4 (100 Ml) , Dithiothreitol (Dtt) (5 Gms.) , Glycine-Reagent Grade -500G , Glycine-Reagent Grade -0.1M , 2- Mercaptoethanol-Reagent Grade (100 Ml) , Chloroquine-Disphosphate-Reagent Grade (25 Gms.) , Wax Sealant (500 Gms.) , 3350 Mw Polythelene Glycol (500 Gms.) , L-Cysteine Hydrocholride Reagent Grade (25 Gms.) , Nacl (Lr) (500 Gms.) , Disodium Edta (500 Gms.) , Tris (Tris Hydroxymethyl) Aminomethane (25 Gms.) , Sodium Barbital-Reagent Grade (25 Gms.) , Ethyl Alcohol-Reagent Grade (500 Ml) , Erythrosin-Reagent Grade (25 Gms.) , Harris Haematoxylin Solution (500 Ml) , Glycerol Lactate (500 Ml) , Turks Solution (250 Ml) , Ph Strips 0.0-6.0 Ph, Resolution: 0.5 Ph Unit (50 Strips) , Ph Strips 6.0-7.7 Ph, Resolution: 0.3-0.4 Ph Unit (50 Strips) , Ph Strips 7.0-14.0 Ph, Resolution: 0.5 Ph Unit (50 Strips) , Ph Buffer Capsules (3 Standard Buffers- Ph 4, Ph 7 & Ph 10)-2 Each , Microtitre Plate U Bottom - 96 Wells (50 Plates) , Test Tubes With Rim (12X100 Mm) (100 Nos) , Test Tubes With Rim (12X75 Mm) (100 Nos) , Capillary Microhematocrit Tubes (2.9) (200 Nos) Specification:1. Size: Length: 75 Mm, Innder Diameter: 1.2 Mm, Wall: 0.2 Mm 2. Capacity: 70 Ul3. Ends Can Be Sealed With Sealing Clay 4. Interior Surface Of Heparinized Tubes Is Evenly Coated With Ammonium Heparin Which Will Not Interfere With Sodium Determination , Sterile Conical Tubes (100 Nos)Specification:1. Capacity: 15 Ml2. Length: 120 Mm 3. Width: 17 Mm 4. Material: Polypropelene5. Dome Top 6. Rcf: 12000 Rpm 7. Storage: -80°C , Sterile Conical Tubes (100 Nos)-50Ml , Sodium Hydroxide Powder (80-100 Mesh) Extrapure (500 Gms.) , Hydro Chloric Acid (500 Ml) , Citric Acid (> 99.5%) (500 Gms) , Potasium Citrate (500 Gms) , Tri-Sodium Citrate Dihydrate (500 Gms) , Sodium Azide (100 Gms) , Bromylin Crude Powder (100 Gms) , Chloroform (500 Ml) , Neutralizing Solution (24 Ml) , Digitonin (1 Gm) , Di-Ethyl Ether (500 Ml) , Ethanol 50%(500 Ml) , Methylene Chloride(500 Ml) , Xylene (500 Ml) , Chymotrypsin(1 Gm) , Vicia Graminea Lectin (Anti-N Lectin)(5 Ml) , Polybrene (5 Gms.) , Pronase (5 Gms.) , Trypsin (100 Gms.) , Di-Butyl Phthalate (500 Ml) , Di-Methyl Phthalate (500 G) , Sucrose (500 Gms.) , Di-Potasium Edta (500 Gms.) , Magnesium Chloride (100 Gms.) , Chromic Chloride (500 Gms.) , Chloramphenicol (5 Gms.) , Dextrose (500 Gms.) , Inosine (500 Gms.) , Neomycin Sulphate (5 Gms.) , Calcium Chloride (500 Gms.) , Sodium Bicarbonate (500 Gms.) , Sodium Carbonate (500 Gms.) , P Nitrophenyl Phosphate (25 Gms.) , Whatmans Filter Paper-100Mm (100 Nos) , Ficoll Hypaque (100 Ml) , Single Channel Variable Pipettes 20 -200 ?L* Technical Specifications For Single Channel Variable Pipettes (Item No: 130 To 132) 1.Extremely Light Pipetting Action By Tension Free Spring Mechanism2.Fully Autoclavable(121°C):Uv Resistant Material, 3.Volume Locking System4.Increments At Least 0.1?1 Fine Adjustment For Pipettes Expect For 100-1000 ?I Volume Pipette Where Increments Can Be Read As 0.5 ?I 5.Suitable For All Brands Of Tips.6.Adjustable For Variable Volume; Fixation Of Adjustable Volumes7.Three Defined Stops(Single Button Operation Preferred)A. Take Up From First Stop,B. Dispensing And Blow Out, C. Tip Ejection 8.Slim Pipette Shaft, 9.Cone For Standard Tips, 10. Safe Cone Filter Lock11. Easy And Safe Tip Ejector Mechanism., 12. Made Of Corrosion Proof Material.13. Accuracy <.98.5%, 14. Precision<. 99.4%, 14. 2 Years Warranty15. Returnable Samples Should Be Provided For Evaluation , Single Channel Variable Pipettes 100 -1000 ?L* , Single Channel Variable Pipettes 5-20 ?L* , Multi Channel Variable Pipettes 30 - 300 ?L*- 8 Channel Technical Specifications (Item No: 133 To 136) 1. Iso 8655 Certified Digital Multichannel Pipettes Of Variable Volume Suitable For All Brands Of Tips. 2. Pipetting Modes: Autodispense, Dispense, Pipetting, Pipetting And Mixing, Manual Pipetting, Sequential Pipetting And Dispensingrangeincrementprecisiontype 5 To 50?L 0.5 Ul2.0 To 0.7%8 Channel5 To 50?L 0.5 Ul2.0 To 0.7%12 Channel 30-300 ?L5 Ul1.5 To 0.3%8 Channel30-300 ?L5 Ul1.5 To 0.3%12 Channel 3.Extremely Light Pipetting Action By Tension Free Spring Mechanism 4. Fully Autoclavable(121°C):Uv Resistant Material 5.Volume Locking System6.Adjustable For Variable Volume;Fixation Of Adjustable Volumes7. Desirable: A History Function, Service Interval Warning, Sequential Tip Ejection8. Should Be Duly Ce Certified Or Approved9. 2 Years Warranty 10. Returnable Samples Should Be Provided For Evaluation , Multi Channel Variable Pipettes 30 - 300 ?L*- 12 Channel , Multi Channel Variable Pipettes 5 - 50 ?L*- 8 Channel , Multi Channel Variable Pipettes 5-50 ?L*- 12 Channel , Pipette Tips 2-20 Ul* (1000 Nos)Description: Used For Accurate Measurement Of Small Volume Fluid Dispensing. Useful For Safety Of Laboratory Personnelspecification: (Item No: 137 To 139)1. Compatible With International Standard Pipettes Attachable By Firm Grip 2. Available In Packs Of 1000 Tips3. Non Sticky In Nature4. Smooth Internal Surface 5. Pipette Should Be Clean, With Patent Tips That Are Sharp And Pointed6. Pink And Blue Transparent In Colour7. Should Not Be Made Of Reused Plastic , Pipette Tips 2-200 Ul* (1000 Nos) , Pipette Tips 200-1000 Ul* (1000 Nos) , Hemocue Cuvettes# (200 Nos) Specification:1. Compattible With Hemocue 301 Instrument+C2372. Should Be Able To Measure The Hb Using Blood From Finger Prickbased On Azide Methohemoglobin Method. , Cuvettes For Plasma Hemoglobin Estimation(100 Nos) Specification: 1. Compattible With Hemocueinstrument 2. Modified Azidemethemoglobin Method , Leishmans Stain Powder (100 Gms.) , Grams Stain Solution Kit , Methanol (5 Litres) , Sponge Ball For Blood Donors , Paper Tumbler For Drinking Milk - Donor Refreshment (100 Nos) , Test Tube - 5Ml With Clot Activator (100 Nos)-Non Vaccum , Test Tube - 5Ml With Clot Activator (100 Nos)-Vacutainer , Glass Slides (100 Nos) , Temperature - Sensitive Indicators (2-6°C) For Monitoring Red Cell Blood Bags , Blood Irradiation Indicator Labels , Autoclave Indicators , Oxygen Mask With All Sizes Venturie Adapter , Re-Breathing Bags - All Sizes , Round Bottom Test Tube (Without Rim: 12X75cm) (100 Nos) , Round Bottom Test Tube (Without Rim: 12X100cm) (100 Nos) , Test Tube Rack Stand For 72 Tubes , Test Tube Rack Standfor 18 Tubes , Vacutainer – 10 Ml Tube Sterile With Acda (100 Nos) , Measuring Cylinder - 250 Ml , Measuring Cylinder - 500 Ml , Measuring Cylinder - 1 Litre , Stainless Steal Forceps - 18 Inch , Storage Vial - 1 Ml (1000 Nos) , Storage Vial - 2 Ml (1000 Nos) , Storage Vial - 3 Ml (1000 Nos) , Storage Vial - 5 Ml (1000 Nos) , Storage Vial - 10 Ml (1000 Nos) , Sterile Microcentrifuge Tubes-0.5Ml (1000 Nos) , Sterile Microcentrifuge Tubes-1.5Ml (1000 Nos) , Papain Cystein Activated -1% W/V , Cell Pack For Hematology Analyser -20 L , Stomatolyser -500Ml , Cell Clean , Plasmalyte( For Cryo Preservation) , Acd Solution- 500 Ml , Autoclave Bags , Coagulation Reagents (Should Be Compatible With Meril Semi Automated Coagulometer-Merilyser) Pt Reagent-10 X 2 Ml , Aptt Reagent-10 X 2 Ml , Factor Viii Assay-3Ml , Fibrinogen- 20 Test , Coagulation Cuvettes-1000 , Calcium Chloride-10Ml , Note:* Item Nos From 184 To 203 - To Be Procure Only After Ascertaining Stock On Hand And Requirement At The Time Of Placement Of Supply Order. General Specification: ( Should Meet Technical Specification As Specified In Minutes Of Technical Specification Committee To Review Specifications Of Blood Bags For The Use In Blood Banks Held On 15-02-2017 Under Ministry Of Health Govt Of India New Delhi)1. Flexible Pre-Sterilized, 2. Pyrogen Free, 3. Non-Toxic, Non-Haemolytic, Biocompatible Material4. No Risk Of Contamination And Air Embolism (Closed System) With All Leak Proof Seals (Disposable Bags)5. Slit On The Both Sides Of The Bags Should Be Enough To Accommodate 5 – 10 Ml Volume Test Tubes6. The Capacity Of The Bag Should Be Enough To Prevent Any Ballooning/Rupture Of The Bag From The Seam When It Is Filled Up With The Requisite Volume Of Blood7. Flexible Non-Kinking, 8. Non-Sticking, 9. Transparent, 10. Leak-Proof, 11. The Tubing Should Have Same Id/Segment Number As That On The Bag12. The Tubes Should Have Multiple Printed Id/Segment Numbers, 13. Side Diversion Pouch, 14. 16 Gauge Ultra-Thin Walled And Straight, 15. Sharp Regular Margins And Beveled Tip22. Cpda-1 (49 Ml I.E. 14 Ml/100 Ml Of Blood) In Collecting Bag, 23. Sagm (100 Ml) In Satellite Bag,24. Clear & Colourless, 25. No Discolouration On Storage At Room Temperature 26. Manufacturer To Supply Anticoagulant Quality Check Certificate, 27. Non-Peal Off, Heat Sealed Labels, 28. Remain Attached Between Room Temperature To -800C With A Transparent Adhesive29. Date Of Manufacturing, Date Of Expiry And Lot Number Must Be Mentioned On Each Bag, 30. The Expiry Date Should Be At Least 2 Years From The Date Of Supply Of Blood Bags To The Institute31. Filled To Normal Capacity Shall Withstand An Acceleration Of 5000G For 30 Min At Temperature 4°C To 24°C Without Becoming Permanently Distorted And Should Withstand Temperature Up To -80°C Without Breakage.32. The Manufacturers Should Have Supplied Blood Bags Continuously And Satisfactorily To Government Blood Banks For A Period Of 5 Years. List Of Such Government Blood Banks Should Be Enclosed. A Satisfactory Quality And Supply Certificate From Any Of The Two Government Blood Banks Should Be Enclosed For Preceeding 3 Years.Blood Bags * Blood Bags With Cpda1 - Single (350 Ml.)* , Blood Bags With Cpda1- Double (350 Ml.)* , Blood Bags With Cpda1- Double (450 Ml.)* , Blood Bags With Cpda1 - Triple (350 Ml.)* , Blood Bags With Cpda1 - Triple (450 Ml.)* , Triple Sagm Blood Bags (450 Ml.)* , Triple Sagm Blood Bags(350 Ml.)* , Transfer Blood Bags (300Ml.)* , Blood Bags (450 Ml.) With Pre Storage Leukocyte Reduction Filters * , Blood Administration Set With Filter* (25 Nos) , Rbc Leukocyte Reduction Filters (Lab Side With Transfer Bag)- 3Rd Generation* , Rbc Leukocyte Reduction Filters (Bed Side)- 3Rd Generation* , Platelet Leukocyte Reduction Filters (Lab Side With Transfer Bag)- 3Rd Generation* , Platelet Leukocyte Reduction Filters (Bed Side)- 3Rd Generation* , Paediatric Blood Bags With Cpda1 (100Ml)* , Blood Bag For Platelet Pooling By Buffy Coat Method With Leukoreduction Filter (4 To 6 Bags) , Platelet Additive Solution (500 Ml) , Penta Blood Bags With Cpda1* , Apheresis Kits For Plateletpheresis , Apheresis Kits For Therapuetic Plasma Exchange , Specifications For All Above Testing Kits From Item No: 204 To 2151. All The Above Mentioned Test Kits Should Be Duly Certified By Statutory Authorities Namely Drug Controller General Of India And Dghs For Use In Blood Banks 2. The Manufacturers Should Have Supplied Test Kits Continuously And Satisfactorily To Government Blood Banks For A Period Of 5 Years. List Of Such Government Blood Banks Should Be Enclosed. A Satisfactory Quality And Supply Certificate From Any Of The Two Government Blood Banks Should Be Enclosed For Preceeding 3 Years.3. 4Th Generation Test Kits Mentioned Above Should Meet Standard Definitions, Parameters As Per Standard Text Books And Duly Certified As 4Th Generation Test Kits By Drug Controller Of India.Testing Kits*Hiv Elisa Test Kits* (96 Tests) , Hiv Elisa 4Th Generation Test Kits* (96 Tests) , Hiv Rapid Test Kits*(50 Tests) , Hcv Elisa Test Kits* (96 Tests) , Hcv Elisa 4Th Generation Test Kits* (96 Tests) , Hcv Rapid Test Kits*(50 Tests) , Hbsag Elisa Test Kits* (96 Tests) , Hbsag Elisa 4Th Generation Test Kits* (96 Tests) , Hbsag Rapid Test Kits Whole Blood/Serum*(50 Tests) , Syphilis Card Test*(100 Tests) -Tpha Method , Vdrl Rpr Test Kits*(100 Tests) , Card Test For Detection Of Pan Malaria (Pf & Pv) Specific Ldh Using Whole Blood * (25 Tests) , Specifications For Gel Card Centrifuge And Incubatorplacement Specificatons (From Item No 216 To 235)1. Thegel Card Centrifuge And Incubatorequipment Should Be Placed And Maintained Free Of Cost Against The Purchase Of Gel Cards Under Contract Agreement For One Year. 2. The Gel Card Centrifuge And Incubator Will Be Placed On The Condition That It Will Be Owned And Maintained By The Firm Entering Into The Contract For Supplying The Entire Immunohematology Items From 194 To 208 3. Equipment To Be Placed In The Premises Of Blood Bank At Jipmer Under A Guarantee For Free Maintenance For The Contract Period.4. Necessary Inspections And Calibration Certificates To Verify The Compliance Of The Placed Equipment For Immunohematology Workup5. Necessary Training Will Have Tobe Given To The Blood Bank Staff Members, If Needed, From Time To Time.6. Supplier Will Place Another Additional Equipment Of The Same Specification And Model Under The Same Terms And Conditions To Cater For Uninterrupted Trouble Free Services. 7. The Supplier Will Give An Undertaking That The Equipment Supplied Is Of The Latest Model And Version Available As On Date Of Entering Into The Contract. 8. The Supplier Should Ensure That Both The Equipments Are Functioning At All Times. In Case Of Failure Of Any One Of The Instruments The Downtime Should Not Be More Than 24 Hours. Only Under Extraordinary Circumstances The Downtime For The Equipment Can Be Increased By A Period, Which Should Not Exceed 72 Hours.9. Suppliers Should Quote For The All Above Items Mentioned Item No From 216 To 235. No Partial Quote Will Be Entertained. If Partial Quote, The Tender For The Above Items Will Be Summarily Rejected. 10. Authorized Distributor Certificate From The Original Manufacturer Should Be Provided.Immunology Kits ( Should Providesamples For Evaluation. Final Selection Will Be Based On The Results Of Such Evalaution. Any Demonstration Or Training Has To Be Provided Before Evaluation)*# Liss Diluent Ii (500 Ml) , Antibody Screening 3 Red Cell Panel-For Column Agglutination Technique (0.8%) , Antibody Screening 3 Red Cell Panel- For Conventional Tube Technique( 3-5% Cells) , Antibody Identification 11 Red Cell Panel For Column Agglutination Technique (0.8%) , Antibody Identification 11 Red Cell Panel- For Conventional Tube Technique( 3-5% Cells) , Antibody Identification 11 Red Cell Panel (Enzyme) For Column Agglutination Technique (0.8%) , Antibody Identitication Extendedred Cell Panel , Red Cell Preserving Solution For Serological Applications , Diluent-I, Modified Bromelin For Blood Grouping And Enzyme Tests (500 Ml) , Red Cell Elution Kits (10 Tests) , Coombs Gel Cardsfor Antibody Screening And Identification-(Igg+C3d)- 6 Tests Per Card , Coombs Gel Cards For Crossmatching(Igg+C3d)-6 Tests Per Card , Coombs Anti Igg Gel Cards-6 Tests Per Card , Abo/D+ Reverse Grouping Gel Cards (24 Tests) , Rh Subgroup +Cw+K Gel Cards (48 Profile) , Dc Screening Gel Cards (12 Profile)-Igg,Igm,Iga,C3d,Ctrl , Dat Igg-Dilution Gel Cards (12 Profile) , Dat Igg1/Igg3 Gel Cards (12 Profile) , Anti Igg1/Igg3/Igg2/Igg4 Dat Card , Nacl Gel Cards--6 Tests Per Card , For Reagents236-284 Igm Will Be Preferred Over Igg Rare Antiserasanti K Card-72Tests , Anti Jka Card-72Tests , Anti Jkb Card-72Tests , Anti Lea Card-72Tests , Anti Leb Card-72Tests , Anti Lua Card-72Tests , Anti Lub Card-72Tests , Anti M Card-72Tests , Anti N Card-72Tests , Anti S Card-72Tests , Anti S (Small) Card-72Tests , Anti Fya Card-72Tests , Anti Fyb Card-72Tests , Coombs Gel Cards For Direct And Indirect Antiglobulin Testing)-6 Tests Per Card , Check Cell , Panocell 16 , Panoscreen 3/4 , Gamma Elu Kit Ii , Gamma Ega Kit , Gamma Lectin System , Gamma Quin , Freeze Dried Papain , R.E.St. , W.A.R.M. , Gamma Peg , Anti-Ina , Anti Inb , Anti-Mia , Anti Mib , Anti K Igm (1-5Ml) , Anti C Igm (1-5Ml) , Anti C (Small C) Igm (1-5Ml) , Anti E Igm (1-5Ml) , Anti E (Small E) Igm (1-5Ml) , Anti K (Small K) Igm (1-5Ml) , Anti Fya(1-2Ml) , Anti Fyb(1-2Ml) , Anti Jka(1-2 Ml) , Anti Jkb (1-2 Ml) , Anti M (1-2 Ml) , Anti N (1-2Ml) , Anti S (1-2Ml) , Anti S (Small S) (1-2 Ml) , Anti Lea (1-2 Ml) , Anti Leb (1-2 Ml) , Anti Lua (1-2Ml) , Anti Lub (1-2Ml) , Anti P (1-2 Ml) , Anti I(1-2 Ml) , Blood Bags For Total Automated Blood Component Extraction* See Also Above As For Blood Bags Specificationsnote:1. Samples/Brochure Listing Product Details/Certificate Certifying Compliance To Specifications Should Be Provided To The Dept. Of Transfusion Medicine, Jipmer Within One Week Afterdisplay Of Successful Bidders In E- Tender.2. In Case Of Non-Receipt Of Samples Within One Week After Display Of E-Tender, An E-Mail Remainder (Mentioned In Tender Form) Will Be Sent To Supply The Same. In Case Of Non Receipt Of Sampleswithin One Week Of Reminder The Bidding Will Automatically Stands Canceled.3. Selection Will Be Made After Evaluation Of Samples/Brochure, Certificatetop And Bottom Quadra And Penta Blood Bags For Totally Automated Component Extraction.*- 350Ml (For Specification Refer Tender Document) , Top And Bottom Quadra And Penta Blood Bags For Totally Automated Component Extraction.*- 450Ml (For Specification Refer Tender Document) , Molecular Typing Reagents Dna Blood Extraction Kit , Primer (500 Ml) , Ssp Kits For Abo Type , Ssp Kits For Rh Type , Ssp Kits For Abo Type- Variant , Ssp Kits For Rh-Partial D , Ssp Kits For Weak D , Ssp Kits For Kkd Type , Ssp Kits For Mns Type , Ssp Kits For Minor Blood Group Type , Ssp Kits For Hpatype , Ssp Kits For Hna Type , Tbe Buffer-1L , Ethidium Bromide , Ethanol-70% , Microtips- 20 To 200 Microlitre (1000 Nos) , Microtips -1Ml-500Ml , Agarose Powder , Bromophenol Blue , Acrylamide , Ammonium Persulphate , Sodium Dodecyl Sulphate-10% , Ammonium Chloride , Ammonium Bicarbonate , Protininase K , Boric Acid , Consumables For Chemiluminscence Systemnote: 1. Samples/Brochure Listing Product Details/Certificate Certifying Compliance To Specifications Should Be Provided To The Dept. Of Transfusion Medicine, Jipmer Within One Week Afterdisplay Of Successful Bidders In E- Tender.2. In Case Of Non-Receipt Of Samples Within One Week After Display Of E-Tender, An E-Mail Remainder (Mentioned In Tender Form) Will Be Sent To Supply The Same. In Case Of Non Receipt Of Sampleswithin One Week Of Reminder The Bidding Will Automatically Stands Canceled. 3. Selection Will Be Made After Evaluation Of Samples/Brochure, Certificatetesting Kits For Fully Automated Immunoassay System – Chemiluminscence, Floor Model Hiv – Fourth Generation Kit With Fourth Generation Controls, Calibrators From Same Manufacturer. (Who P24ag Int Std90/636) < 0.90Iu/Ml) (100 Tests) (For Specification Refer Tender Document) , Hbsag - Capable Of Qualitative Detection Of Hepatitis B Surface Antigen (Hbsag) With Excellent Mutant Detection. (100 Tests) (For Specification Refer Tender Document) , Hcv - Capable Of Qualitative Detection Of Antibody To Hepatitis C Virus (Anti-Hcv). (100 Tests) (For Specification Refer Tender Document) , Syphilis - The Assay Should Be Able To Detect Treponema Pallidum Specific Antibodies Of Both Igm And Igg (100 Tests) (For Spec Please Refer Tender Document) , Equipments , Water Bath-Laboratory Rangespecifications:1. Dimensions (External) 40 Cm X 40 Cm X 20Hcm (Approx.) 2. Dimensions (Internal) 30 Cm X 30 Cm X 15Hcm (Approx.) 3. Double Wall Insulated Metal Body, 4. Temperature Range 37ºc -100ºc, 5. Digital Temperature Control And Display6. Temperature Precision 0.1ºc, 7. Should Have Provision To Maintain Uniformity Of Temperature8. Should Have The Provision To Incubate Racks Of All Size Of Test Tubes, 9. Illuminated On Switch, 10. Indicator Light Showing Heating Element Operation, 11. Temperature Control 12. Demonstration Of Performance Of Equipment Is Compulsory In Nearby Area Failing To Which Will Lead To Disqualification., 13. Electrical: The Equipment Should Be Able To Run On The Existing Electrical Provision 14. Should Be Bis/Ce/Fda Approved Product, 15. Warranty-02 Yrs. , Blood Transportation Box Specification: 1. Extended Cold Life, 2. Fixed Two Temperatures Setting Adjustable To +4°C And +22°C. 3. Capacity To Accommodate Minimum 48 Blood Bags Of 450 Ml.C33, 4. External Dimension Of Each Transportation Box Should Be Within 1000 -1500Mm (L)X 800-1000 Mm (W)X 600- 700 Mm (H)5. Chest / Vertical Cabinet With Built In Handles And Hinged Door., 6. Body Material Should Be Polyethylene (Corrosion Free)7. Smooth Castors With Stabilizers For Flexibility And Movement., 8. Ambient Working Temperature -2°C To +43°C, 9. Main Power Switch.10. Microprocessor Based Temperature Controller With Integrated Audio Visual Temperature Alarm Function On Digital Monitoring Display. 11 .Separate Selector Switch For + 4°C And +22°C Temperature Settings., 12. Nominal Dc Power 12 / 24 Volt And Nominal Ac Power 100 – 240 Volt, 50/60Hz. 13. Automatic Ac / Dc Power Supply Selection., 14. Automatic Cooling / Heating Operation., 15. Air Cooled Hermetically Sealed Dc Compressor., 16. Vehicle Fixation Kit.17. Controlled Fan Cooling System For Constant Air/Temperature Distribution., 18. For Storage Of Blood Bags, Minimum Two (2) Wire Basket Should Be Provided In Each Box.19. Power Alarm Audio And Visual By Led. Audio Alarm Can Be Switched Off. Temperature Audio And Visual High And Low Alarm By Led.20 .Minimum Polyurethane Insulation Cfc Free For The Cabinet And The Door., 21. Warranty-02 Yrs. , Binocular Microscope (Without D.G) Specification: 1. Head:Binocular 30° Inclined And Rotatable 360° 2. Eyepieces:10X 20Mm Fov 3. Nosepiece:Reversed, Quadruple 4. Objectives:Plan Achromat 4X, 10X, 40X, 100X Oil5. Condenser:1.25 N.A. 6. Stage:Rackless Mechanical Stage 7. Focusing:Coaxial Coarse/Fine Focus System With Limit Stopper And Torque Adjustment 8.Focusing:Coaxial Focusing System With An Adjustable Tension Control And Upper Limit Stop To Prevent Accidental Damage To Slides; All Metal Gears, Brass Fine Focus Gear 9. Illumination:Led Illumination Variable With Cord Holder 10. Warranty: 5 Years , Table Top Centrifugespecification: 1. Speed Max : 100-6000 Rpm, Rcf: 5030Xg, 2. Automatic Rotor Identification.3. Heavy Duty Brushless Induction Motor For Low Vibration And Noise < 65 Db, 4. Presetting Of Speed And Time And 0-99 Minutes Digital Timer5. Safety Lid Interlock, 6. Digital Speed Indication, 7. Digital Indicator Cum Controller, 8. Dynamic Break And Imbalance Detector With Cutoff 9. Angle Head Rotor With 24 X (5-15Ml Tubes) With Appropriate Tube Adapters Should Achieve Rpm 4500 Or More & Rcf 3300 G Or More 10. Rust Proof Stainless Steel Inner Chamber, 11. To Work On 220 Volts Ac, 50 Cycles12. To Be Supplied With Suitable Servo Controlled Stabilizer, 13. Manufacturer Should Be Iso 13485 Certified., 14. Warranty - 2 Years , Rh View Boxspecification: 1. Built-In Temperature Indicator For Easy, Accurate Monitoring Of Viewing Area. Viewing Area Temperature Adjusts Easily To Compensate For Ambient 2. Temperature Changes. (Range: 45°C To 50°C) 3. Rh Slides Reaches Temperature Of 37°C To 39°C In Two Minutes, Eliminating Wasted Heat Up Time. 4. Soft, Fluorescent, Glare Free Light Provide Uniform Illumination Of Slide Contents. 5. View Box Can Be Gently Rocked Using Large Knob On Support Cradle. 6. Sturdly, Easy-To-Clean Metallic Powder Compact Case. Utilizes Minimal Bench Space. 7. Meets Rh Slide Test Standard Set By The Aabb., 8. Unit Conveniently Includes Three-Wire Cord And Plug. 9. Light - Fluorescent Glare Free, 10. Temp Display - 37°C ± 2°C11. Power - 220 V - 50Hz, 12. Warranty - 2 Years , Specific Gravity Meter Specification: 1. Should Read Specific Gravity From 1.000 To 1.140?2. Hydrometer Should Have A Solid Shot-Weighted Float And An Extra Long Stem For Grasping3. Jar Should Be 5 In. (13Cm) High With Extra Wide Base 4. Warranty - 2 Years , Digital Specific Gravity Meter Specification: 1. Should Read Specific Gravity From 1.000 To 1.100?2. Digital Display3. Warranty - 2 Years , Hot Air Oven - Laboratory Usespecification:Operational Requirementsmicroprocessor Based System With Pid-Temperature Controller With Integrated .Auto Diagnostic System With Fault Indicator.Technical Specifications1. External: Stainless Steel Casing :Insulated Stainless Steel Door With Locking And Rear Zincplated Steel 2.Interior - Internal Volume More Than 200 Liters Easy-To-Clean Interior, Made Of Stainless Steel,With Supports On The Three Sides For Three Adjustable Perforated Stainless Steel Shelves 3. Forced Air Circulation By Quiet Air Turbine/Fan To Ensure Uniform Temperature 4.Fitted With Load Indicator And Safety Thermostat Take Over Indicator Lamp. Lcd/Led Indicator5. Temperature Variation +/- 1 Deg C., 6. Temperature Range- Ambient To 250 Deg C., 7. Output Available For Data Acquisition. Environmental Factors: 1. The Unit Shall Be Capable Of Being Stored Continuously In Ambient Temperature Of 0 -50Deg C 2. The Unit Shall Be Capable Of Operating Continuously In Ambient Temperature Of 10 -40Deg C And Relative Humidity Of 15-90%3. Warranty - 2 Years , Agglutination Viewers For Blood Bank Specification: 1. Designed For Use In Blood Typing, Cross Matching, Antigen Typing, Titers And Other Agglutinations Tests 2. Illuminates Test Tube Contents Through The Use Of A 5-Watt Bulb From Above And A Magnifying Mirror From Below3. Easy To Use Side-Mounted On/Off Switch 4. Flexible Neck Allows For Easy Manipulation Of Light Source 5. Input: 120V 60 Hz, 18W; Output: 12Vac 500Ma6. Warranty: 2 Years , Cold Chain Boxes (4 Pack Vaccine Carriers) To Transport Blood To Wards (Blue - 150 Nos, Pink-150- Nos, Yellow - 100 Nos, White-100 Nos)Specification: 1. Storage Capacity: 1.63 Litres2. Lid Type And Fixings: Removable 3. External Surface Material: Hdpc4. Internal Lining Material: Hips5. Insulation Material: Cfc-Free Polyurrethane 6. Insulation Thickness: 35-38 Mm7. Number Of Ice Packs: 4 X 0.4 Litres 8. Cold Life Without Opening , Tested By Who Approved Laboratory: 4 Hours At 6°C 9. Warranty: 2 Years , Vdrl Shakerspecification: 1. Platform Size 12” X 12” For Keeping Reaction Trays.2. Timer With 0 To 30 Minutes For Control Of Shaking Duration With 1 Minute Interval.3. Should Have Built In Speed Regulator With Maximum Speed Of 150-180 Rpm. 4. Warranty: 2 Years , Plasma Thawing Bathspecification: 1.Unit Should Thaw Atleast 8 Plasma Units In Less Than 20 Minutes. 2.Digital Electronic Bench Top System With Led Display. 3.Should Have 2 Separate Basket Asemblies Securely Holding Plasma Bags4.Water Bath Based Operating System At A Preset And Precise Temperature Of 37°C ± 0.5°C5.Should Give An Alarm When The Plasma Bags Are Thawed. 6. Provision For Programmable Time Setting For Length Of Thawing With Audio Completion Signal.7. Should Have Audio Visual Over-Temperature Alarm System8. Should Have A System To Drain The Chamber. 9. Should Have A Deep Thawing Chamber With A Stirrer10. Warranty: 2 Years , Blood Bag Digital Weighing Balance - Double Pan Specification: 1. Should Be An Electronic Differential Scale. 2. Weight Measurement - 0-2500 Grams (Range) 3. For Weighing 2 Blood Bags Simultaneously For Balancing For Centrifugation Purposes & Should Display The Difference Of Two Loads.4. Maximum Weight Difference - 2500 Grams, 5. Weight Sensors - Load Cells 6. Weight Display Panel - 4-Digit Led Display, 7. Weight Calibration Tolerance - +/-1 Gram 8. Decimal Truncation Error - 1 Gram, 9. Total Accuracy Of Display - +/-2 Grams 10. Weight Accuracy - 4 Grams, 11. 18V Dc (A/C Power Adapter 100-120/220-240 V A/C In) 12. Power Consumption - 5 Watts, 13. Warranty - 2 Years , Blood Bag Digital Weighing Balance - Single Panspecification: 1. Should Have A Microprocessor Based Single Pan Analytical Balance With High Accurary And Precision Is Required 2. Should Have Weigh Accuracy Of Upto Iii Decimal Place, 3. Should Have A Auto-Self Calibration Facility4. Should Have A Auto Zero Setting., 5. Shoud Have One Touch Calibrationj.6. Should Have Weighing Capacity Upto 500 Gm, 7. Should Have A Readability And Repeatability 0.001/G 8. Should Have Stabilization Time <5 Secs., 9. Should Have Lcd Display For Showing Weight. 10. Power Input To Be 220 V To 240 V. Ac, 50 Hz 11. Should Provide With Suitable Ups With Maintenance Free Batteries For Minimum One Hour Back Up, 12. Warranty: 2 Years , Hemocue Testing Systemspecification: 1. Should Be Able To Measure The Hb Using Blood From Finger Prick (Should Be Based On Azide Methohemoglobin Method).2. Should Be Capable Of Displaying Results Within 1 Minute, 3. Accuracy ± 1 %4. Disposable Cuvettes. Cost Of Consumables To Be Quoted Along With This Tender As It Will Be Considered For Financial Comparison., 5. Should Be Portable And Should Have The Battery Backup For 8 Hours Or More With Provision Of Electric Operations .6. Factory Calibrated And Calibration Should Be Verified Automatically Time When The Instrument Is Turned On., 7. Should Have The Memory To Store At Least 500 Results With Date And Time And Should Be Able To Transfer The Results To Pc.8. Should Be Us Fda Or European Ce Class-2A Or Bis, 9. Should Be Iso 13485 Approved Product., 10. Original Literature Of Equipment Should Be Submitted., 11. Warranty: 2 Years , Table Top Incubatorspecification: 1. The Incubator Should Be Suitable For Incubation Of Elisa Plates Of Tti Markers, 2. Dimensions Should Be Approximately 355 X 355 X 355 Mm3. Should Be Sturdy, Double Walled Construction With Complete Inner Chamber Made Of Anodized Aluminum Or Highly Polished Stainless Steel. 4. Gap Between The Walls Should Be Filled With Special Grade Insulation Material For Proper Insulation And To Avoid Heat Losses. 5. Should Have Inner Chamber Fabricated With Ribs For Adjusting Shelves To Convenient Height., 6. Should Be Supplied With 2 Or 3 Removable Shelves. 7. Heating Element Should Be Placed At The Bottom And Side Ribs For Uniform Temperature All Over The Space.8. Should Have The Temperature Control By Thermostat From 20ºc Above Ambient To 50ºc ±0.5ºc. Temperature Control Knob Should Be Graduated In Degrees Centigrade. 9. Should Be Provided With Air Ventilators Port On Sides At Top For Ventilate Fumes & To Assist Convection Process. 10. The Equipment Should Be Provided With A Panel Having A Thermostat Control Knob, On/Off Switch And Indicator Light. 11. Firm Should Also Provide The Relevant Temperature Calibration Certificate For The Equipment From Any Nabl Accredited Lab., 17. Warranty: 2 Years , Domestic Refrigerator Specification: 1. Capacity: 300 Ltrs ( Double Door)2. Material: Stainlees Steel Puf3. Interior Light4. Reversible Door Opening 5. Condensation Drain 6. Voltage: 220 V 7. Warranty: 2 Years , Bp Apparatus Self Check Dial Arm Type Sphygmomanometerspecification: 1. Should Be Aneroid Type, 2. Should Have Isi Mark., 3. Should Have A Measuring Range From 0 To 300 Mmhg 4. Should Be Provided With Adult Arm Cuffs Of Size Medium & Large And Paediatric Cuff. 5. The Dial Mano Meter Markings And Graduations Should Be Permanent And Clearly Visible And Filled With Pigments, With Diameter Of Minimum Diameter Of 160 Mm 6. Body & Bazel – Aluminium Die Casted (Powder Coated), Screw Type Bazel, 7. Sensing-Corrogated Phosphorous Bronze Twin Capsule Bellows., 8. Movement Mechanism – Brass, 9. Connection : Brass, Nickel Plated For 3-4 Mm Rubber Hose 10. Dial – Aluminium, 11. Pointer – White Coated, Thin & Sharp Made Of Phosphorous Bronze, 12. Window Lenses – Clear Plastic. 13. All Plastic Parts, If Any Used Should Not Crack, Flake, Peel Or Disintegrate In Normal Use., 14. The Inflating Rubber Bag Should Be Capable Of Withstanding An Internal Pressure Of 450 Mmhg Without Leaking.15. The Inflating Bulb Should Be Soft And Should Not Have Any Joints Or Ridges., 16. The Fastening Arrangements Of The Cuff Should Be Of Hook And Loop Type (Velcro) 17. The Threading And Fastening Arrangement Of The Cuff Should Show No Sign Of Slip Or Failure When Subjected To The Maximum Test Conditions.18. The Rubber Tubes Used Should Have An Internal Diameter Of 3 ± 0.5Mm And The External Diameter Should Not Be Less Than 8Mm., 19. The Tubes Should Be Fitted With Male And Female Leur Connectors.20 .Should Provide A Carry Bag To Keep The Whole System Safe And Sound. All Parts Should Be Replaceable In Case Of Breakage., 21. Warranty: 2 Years , Insecticutors Description: Insecticutors Are Required In Bleeding Area, Donors Screening Area, Issue Section For Controlling Flies And Other Insects Which May Contaminate Blood Components. Specification: 1. Powder Coated Body For Long Lasting & Durability2. Phillips Uv Tubes 3. Copper Wiring And Copper Choke For Electricity Saving4. Rugged 3 Kv Transformer 5. Zinc Coated Grid To Prevent Rusting 6. Collection Tray For Killed Flies7. Pvc Coated Guard To Avoid Shock8. Low Power Consumption 9. Warranty: 2 Years , Hot And Cold Water Dispenser For Drinking Purposedescription: Provides Safe Drinking Water For Blood Donors 1) Provides Cool Drinking Water At Blood Donation Camps 2) Decreases Chances Of Vasovagal Blood Donor Reactions. 3) Positively Enhances Donor Reaction Affecting Donor Retention. Specification: 1. Quiet Operation, Runs On Electricity And Easy To Clean., 2. Anti Corrosive And No Costly Maintenance3. Plain / Hot / Cold Water Option Available, 4. Compact Design Taking Very Less Space.5. Long Lasting Plastic Front Panel And Faucets, 6. Convenient Removable Drip Tray 7. Led’S To Indicate Primary Function, 8. Low Power Consumption 9. Bimetal Sensors To Ensure Overheating Protection, 10. Weight Less Than 20 Kg, Compact And Mobile 11. Spill Proof Bottle Holder - Optional, 12. Warranty: 2 Years , Vein Illumination Device Description:It Is Used To Visualize Subcutaneous Veins By The Phlebotomist. Useful For A) Prevent Deferrals Because Of Poor Venous Access B) Preventing Loss Of Unit Because Of Inefficient / Insufficient Collection C) Useful For Training Phlebotomist And Building Their Confidence D) Enhances Donor Experience E) Decreases Chances Of Apheresis Procedure Failure F) Non Contact Venous Assessment For Phlebotomyspecification: 1. Based On Infra Red Technology, 2. Clearly Displays Subcutaneous Vasculature Without Any Contact With Skin3. No Need For Calibration Or Adjustments, 4. Includes Charging Cradle And Power Supply Cord 5. Run Time Of At Least Two Hours Per Charge, 6. More Than 300 Vasculature Visualizations Per Charge7. Accessories Available Like: 1) Stand For Hands Free Operation With And Without Charger 2) Clamps For Fixing For Hands Free Operation 3) Mobile Hands Free Operation 6) Padded Carry Case With Shoulder Sling 4) Belt Carry Case., 8. Warranty: 2 Years , Microplate Shaker Specification:1. Platform Size 12” X 12” For Keeping Reaction Trays.2. 4 Number Of Microplates Can Be Kept At A Time3. Timer With 0 To 30 Minutes For Control Of Shaking Duration With 1 Minute Interval.4. Should Have Built In Speed Regulator With Maximum Speed Of 150-180 Rpm. 5. Warranty: 2 Years , Vacuum Cleaner (Hand Held) Specification:1. Special Features: 2 Tier Radial Cyclones, Direct-Drive Motor, Washable Pre-Motor Filter 2. Cleaning Method: Dry 3. Cleaner Type: Handheld 4. Included Tools: Combination Nozzle, Extension Hose, Futon Tool, Gap Nozzle, Mini Motorized Tool 5. Warranty: 2 Years , Phlebotomy Mannequinspecification:1. Advanced Venipuncture And Injection Arm - White Which Gives Complete Venous Access For Phlebotomy As Well As Iv Therapy, Plus Sites For Intra-Dermal And Intramuscular Injections.2. Injectable Metacarpal, 3. Digital And Thumb Veins4. Median Cephalic, 5. Median Basilic 6. Median Cubital Veins, 7. Basilic 8. Cephalic, 9. Accessory Cephalic10. Median Antibacterial Veins, 11. Deltoid Muscle, 12 .Warranty: 1 Year , Microplate Centrifuge Specification:1. Speed: 300-3000 Rpm With Increment Of 10 Rpm, 2. Max Rcf: 2000 X G Or More, 3. Automatic Rotor Recognition And Imbalance Detection. 4. Manufacturer Should Provide Compatible Set Of Microplates With Specifications Of The Same., 5. Timer: 0 To 60 Mins. Continuous Operation 6. Drive System: Brush Less Induction Drive, 7. Noise Level At Max Speed Should Be Less Than 60Db 8. System Should Have Safety Features Like Lid Lock And Interlock9. System Should Have Microprocessor Controlled Pre-Selection And Display Of Speed And Time.10. Manufacturer Should Be Iso 13485 Certified., 11. The Centrifuge Should Be Provided With The Following Accessories 12. Speed: 300-4000 Rpm Or More, 13. Rcf: 2000X G Or More 14. Capacity: Should Be Able To Centrifuge 2 Microplate Of 96 Wells 15. Rotor Head Should Be Available With The Firm For Immediate Replacement, 16. Warranty: 2 Years , Cryoprecipitatebath Specification:The Cryo Bath Is Designed For Rapid And Uniform Thawing Of Fresh Frozen Plasma Bags At 4 ºc +/- 0.2 ºc Such That The Cryoprecipitate Remains Solid, And A Cryosupernatant Liquid Is Formed That Can Be Transferred Out Of The Bag In Order To Manufacture Cryoprecipitate Units.Ii Operational Requirements: 1. Floor Standing System, Mounted On Lockable Castors. 2. Should Be Having Capacity Of 12-18 Bags Per Run For One Cycle. 3. Should Be Able To Thaw Ten To Twelve Plasma Units (Ffp ~200-300 Ml) At A Time. 4. Should Have Stainless Steel Tank Of 22G, And An Insulated Lid Covered With 20G Stainless Steel, 5. Should Be Fitted With Compartments That Have Removable Rack/Tray System For Securely Holding The Plasma Bags And Ensuring That Entry Ports Are Not Contaminated With Water.6. Should Be A Microprocessor Controlled Water Bath Based System Operating At A Temperature At 4 ºc +/- 0.2 ºc Or Alternative Can Also Be Safely Set At 37 ºc +/- 0.2 ºc.7. Digital, Electronic System With Provision For Programmable Temperature Adjustment Setting With Led Display With Temperature Resolution Of 0.1 ºc, 8. Should Not Take More Than 2 Hours At Full Loads To Thaw The Plasma Into Cryosupernatant. 9. Should Have A Deep Thawing Chamber With A Stirrer For Water Circulation & Gentle Rocking For Uniform Heating By High Capacity Pump, 10. Should Have A System To Drain The Chamber Without Lifting Or Tilting, And Should Be Fitted With A Shut Off Valve.11. The Unit Shall Be Capable Of Being Stored Continuously In Ambient Temperature Of 0 -50Deg C And Relative Humidity Of 15-90% Without Getting Rusted. 12. Compatible With Input Voltage: 240V 50 Hz Single Phase Ac14. Should Have An Integrated Voltage Stabilizer Or External Servo Stabilizer Of Appropriate Ratings Meeting Isi Specifications (Input 160-260 V And Output 220-240 V And 50 Hz). 15. Resettable Overcurrent Breaker Shall Be Fitted For Protection, 16. Warranty: 2 Years , Blood Collection Monitorspecification:1. The System Is Used To Collect Donated Blood From The Donor At The Same Time Mixing The Blood For Quality Collection Of Blood.2. Pre-Selection Of Volume To Be Collected. Tarring Of Bag Volume Before Collection. Tarring Range: 0 – 600 G. Automatic Storage And Recall Of Set Volume. Measure Volume With Best Accuracy 3. Led Indication On Commencement Of Collection., 4. Led Indication And Audible Alarm At The End Of Collection., 5. Indication Of Time Taken For Collection.6. Indication Of Blood Flow With Audio Alarm When Blood Flow Is Higher Or Lower Than Desired. Continuous Display Of Collected Volume, Flow And Time During Collection7. Automatic Clamping At Termination Of Preset Volume Collection, 8. Automatic Release Of Bag When Lifted., 9. Continuous Agitation Of Blood Bags During Collection: 12 – 16 Rpm., 10. Easy Provision To Change Preset Volume. 11. Should Operate On Mains As Well As Rechargeable Battery. On Battery It Should Operate For A Minimum Of 5-8 Hours., 12. Should Be Less Than 5 Kg 13. “ Pause Facility” To Pause The Collection. 14. Optional- Memory To Store Donation Data Such As Donor Number, Name Of Operator, Volume Collected, 15. Should Measure Volume With Accuracy Less Than 1 %16. The Unit Shall Be Capable Of Operating Continuously In Ambient Temperature Of 10 - 400 C And Relative Humidity Of 15-90%, 17. Power Input To Be 220-240V Ac, 50Hz As Appropriate Fitted With Indian Plug18. Should Be Technologically Advanced With Modern Blood Collection Scale And Mixer. It Should Be Light Weight & Portable., 19. Warranty: 2 Years , Gelcard Incubator Specification:1. Dedicated To Centrifuge Usa Fda Approved, Sephadex Gel Micro Typing System Cards Based On Column Agglutination “Gel Technology”.2. Usa Fda Approved, Sephadex Gel Micro Typing System Cards Based On Column Agglutination “Gel Technology”. 3. Incubator Should Have The Capacity To Incubate The Gel Card And Test Tubes For 37° 4. Automatic Balance Control 5. Warranty: 2 Years , Gelcard Centrifugespecification:1. Dedicated To Centrifuge Usa Fda Approved, Sephadex Gel Micro Typing System Cards Based On Column Agglutination “Gel Technology”. 2. Centrifuge Should Have Option To Run Gel Card And Test Tubes, 3. Silent Centrifuge For Holding 24 Cards. Each Card With 6 Micro Wells 4. Automatic Balance Control, 5. Centrifugation Time: 10 Minutes Or Less 6. Speed, Time And Functions Are Digital Display, 7. Typing System Cards With ‘V” Shaped Bottom For Clarity In Results. 8. Monitored By Microprocessor., 9. Suitable Rpm.10. Gel Cards Should Be Made Available For Abo& Rh Grouping, Rare Blood Group Antigens, Coombs Test, Pnh, Partial D Typing And Etc., 11. The Price Of The Card Should Be Frozen For A Minimum Period Of Three Years12. 110V-240V/50Hz- 120Hz., 13. Bis/Ec Conformity.11. The Price Of The Card Should Be Frozen For A Minimum Period Of Three Years14. Enough Diluents And Abo Grouping Cards For 100 Tests And Coomb’S Card For 400 Tests With Adequate Diluents., 15. Warranty: 2 Years , Colorimeter- For Hemoglobin Estimation By Drabkins Method Specification:1. It Should Be Portable & Work On 220V & 5 Amp.2.It Should Have Built In Minimum Of 3 Filters With 500, 540 And 600Nm 3. It Should Come With Minimum Of 5 Cuvettes4. Display Should Be Digital5. It Should Be Easily Calibrated 6. Warranty-2 Years , Digital Ph Meter With 3 Standard Buffersspecification: 1. Should Have Working Range From 0 To 14., 2. Should Have Resolution 0.1/0.01 Ph 3. Should Have Temperature Compensation Zero To 100 Degree C With Atc4. Should Have Rs.232C Output And Supply Data Connector Cable5. Should Have Automatic Calibration Facility., 6. Should Have 3 Stage Calibration.7. Should Have Digital Display With 0.001 Ph Unit Readability, 8. Should Supply Tri-Combination Ph/Atc Electrode 9. Should Supply Electrode + Standard Buffer Solution (Ph 4.0, 7.0, 10.01 X 50Ml For Each Bottle) + Standard Electrode Holder +Ac /Dc Adaptor. 10. Should Be Provided With An Electrode Holder/Arm With Smooth Movement, 11. Warranty - 1 Year , Blood Bag Multifunction Hand Striper, Sealer And Cutterspecification: 1. The Body Should Be Made Of Pure Stainless Steel 2.The Handles Should Be Covered With Plastisol 3. Weight Should Be Less Than 200 Gms. 4. Should Be Certified By Ce And Iso 9001 5. Easy To Handle, Strip, Mix, Seal And Cut During Non Use 6. Warranty: 2 Years , Induction Stove Description: Required To Boil Milk And Water For Donor Refreshment Specification: 1. Single Stove, 2. Heating With Warming Facility3. Child Lock, 4. Capable Of Cooking Under Fan/In Ac 5. Protection From Over Heating, 6. Surface Safe To Touch During Operation 7. Protection From Spilling Of Food Items, 8. Programmable For Time And Temperature 9. One Touch Fixed Program And Fixed Timer Facility, 10. Digital Display11. Auto Menu, 12. Utensil Detection, 13. Power Saving 14. Bis/Ce/Iso Certified, 15. Warranty - 2 Years , Sonicator - Ultrasoundcleaning Bath Specification: 1. Fitted With Microprocessor Based Digital Temperature Indicator-Cum-Controller At Any Temperature From Ambient +5ºc To 60ºc.2. Should Have A Digital Timer With Settable Range From 0-15 Min Or 0-30 Min (Depending Upon The Capacity Ordered). 3. Extensively Protected Electronic Circuits Means Longer And Safer Operations., 4. High Frequency Electrical Energy Is Converted Into Ultrasound Waves By Means Of Ultrsonic Transducers. 5. Compact, Rugged And Highly Durable System., 6. Efficiency Of 90% Permits Maximum Cleaning Action, Low Power Consumption.7. Extensively Protected Electronic Circuits Means Longer And Safer Operations., 8. Automatic Frequency Tuning For Maximum Output. 9. Input Range Of 170Vac-270Vac, Highest Immunity To Input Supply Variations.10. Pre-Set Auto Degassing Function., 11. Pulse Sweep Power For Better Effective Cleaning.12. To Work On 220/230 V Ac Supply., 13. Warranty: 2 Years , Spectrophotometerspecification: 1. Wave Length Range: 190 To 1100 Nm 2.Spectral Band Width: 1 Nm3. Wave Length Display: 0.1 Nm Increments 4. Wave Length Accuracy: ± 0.1 Nm 5. Photometric System: Double Beam6. Photometric Accuracy: ± 0.002 Abs 7. Baseline Statbility: Less Than 0.0003 Abs8. Noise Level: Within 0.00005 Abs Rms Value (At 700Nm) 9. Warranty: 2 Years , Plasma Expressormanual Specification: 1. Should Be Suitable To Manually Express Blood Components (Plasma, Platelets) From Collection Blood Bags. 2. Front Panel Should Be Spring Loaded To Apply Uniform Pressure On Container Causing Transfer Of Fluid. 3. Compression Plate Should Be Made Of Durable Transparent Acrylic4. Metal Used For The Apparatus Should Be Non-Corrosive And Can Be Cleaned With Antiseptics 5. Base Portion And Vertical Surface Should Be Made To Have Better Strength And Longlasting Performance 6. Quality Certification: Iso 13485 Certified7. User?S List Should Be Attached With Satisfactory Report For The Last Three Years From Three Users With Contact Details. 8. Demonstration Of Performance Of Equipment Is Compulsory In Nearby Area Failing To Which Will Be Disqualification.9. Warranty - 1 Year , Dry Block Incubator Specification: 1. Basic Device Without Exchangeable Thermoblocks. 2. 16 Tube Holders- Test Tube Size 12 X 75Mm And 12 X 100Mm3. Temperature Control Range:-50C To 99 º C. 4. Accuracy Of Temperature Control : At 0º C ± 1.0ºc 5. At 37º C± 0.5ºc And At 90º C± 1.0ºc, 6. Heating-Up Speed: Approx. 5º C / Min 7. Range Of Time Phases 0:01To 99.59 Hrs, 8. Power Supply: 100 - 240 V, 50 - 60 Hz, 9. Precise Temperature Control10. The Temperature And Run Time Can Be Programmed Individually Upto 4 Temperature Levels And 4 Time Phase In Succession, 11. Warranty - 2 Years , Vertical Reagent Refrigeratorspecification: 1. Storage Capacity: Should Be At Least 300 Liters Capacity, 2. Set Temperature 4ºc With Temperature Range 2ºc To 6ºc And Adjustable With Setting Accuracy Of ±0.5ºc3. Refrigeration: Non- Cfc Cooled Refrigeration, 4. Should Have Good Insulation To Maintain Required Temperature5. Should Have Good Metallic Door With Removable Shelves Inside For Easy Cleaning.6. Microprocessor Based Temperature Controller With Integrated Audiovisual Temperature And Power Alarm Function With Digital Monitoring Display.7. Safety Features: Audio Alarm For All The Following Parameters Should Be There: Temperature Fluctuation & Power Failure, Set Point Alarm, Low Alarm Point, Door Opening Audio And Visual Display Alarm. 8. Safety Thermostat To Avoid Negative Temperatures., 9. Should Have Battery Back Up For Temperature Display And Power Alarm., 10. Interval Temperature Hold Over Time In Case Of Power Failure Should Be At Least 1.5 Hours. 11. Should Have Castor Wheels With Locking Facility, 12. Original Literature Of Equipment Should Be Submitted., 13. Manufacturer Should Be Iso 13485 Certified. 14. Firm Should Supply The Relevant Calibration Certificate For The Equipment From Nabl Accredited Lab., 15. User?S List Should Be Provided With Satisfactory Report For The Last Years From Three Licensed Blood Banks With Contact Details.16.Firm Will Have To Supply The Stabilizer If Required Along With The Equipment Free Of Cost., 17. Bidder Have To Arrange Demonstration Of The Quoted Model (If Required)18. Electrical: The Equipment Should Be Able To Run On The Existing Electrical Provision, 19. Should Provide Datalogger Or Circular Chart Recorder, 20. Warranty: 2 Years , Blood Bag Tube Sealer (Table Top)Specification: 1.Blood Bag Tube Sealer Is A Compact Equipment To Seal The Blood Bag Pilot Tube By Radio Frequency Sealing System, 2. Should Be Capable Of 750 Seals Per Hour Or 1500 Sealing Per Charge Battery. Capable Of Sealing Tubes Of Various Manufacturers Of Blood Bag.3. Should Be For Table Top Use., 4. The Sealing Time Should Be Adjustable Between 0.5-5 Seconds, 5. Sealing Triggering Should Be Automatic 6. Should Detect Wet Tubes, Leakage Or Any Sealing Defect., 7. Should Have Indication Lamps For “Sealing Process” On Handle As Well As Main Unit And Led To Show The Battery Test., 8. No Warm-Up Time Should Be Required.9. Should Ensure Easy Separation Of Tube Segments After The Sealing. Should Have Separable Rupture Line., 10. System Should Run On Both Mains And Battery (More Than 10Hrs. Back Up When Fully Charged).11. Should Be Light Weight Less Than 3 Kg With Carry Bag., 12. Tube Thickness Of Up To 6 Mm Of Diameter And Wall Thickness Up To 0.75 Mm Can Besensed And Sealed Automatically.13. Should Be Able To Making Wide Seal Of 2Mm Thickness., 14. Indication Of Seal In Progress Should Be There., 15. Sealing Time Should Be Less Than 2 Sec., 16. Separable Rupture Line To Separate Tube After Sealing.17. Should Ensure Safety Against Electrical Shock Hazards, Fire Hazards, And Mechanical Hazards. 18. There Should Be No Hemolysis Of Blood In The Tube Segments, 19. No Warm-Up Time Should Be Required, 20. Should Be Able To Withstand Voltage Fluctuation, 21. It Should Be Easy To Clean. 22. Should Be Easy To Handle With The Grip To Hold The Sealers, 23. Splashguard To Protect User From Any Kind Of Blood Splash During Operation., 24. Manufacturer Should Be Iso 13485 Certified. 25. Weight Of Equipment Should Not Exceed 7 Kg., 26. Original Literature Of Equipment Should Be Submitted., 27. Firm Will Have To Supply The Suitable Stabilizer With The Equipment If It Is Essential For The Performance Of The Equipment., 28. Warranty: 2 Years , Electronic Analytical Balancespecification: 1. Electronic Balance With Transparent Case., 2. Digital Display Of Weight And Other Parameters Should Be Available. 3. Readability 1 Mg, 4. Capacity 1 Mg – 2000G, 5. Accuracy ±1 Mg 6. Stabilization Time Less Than 10 Sec, 7. Should Have Facility For Automatic Calibration With Tare Option.8. Original Literature Should Be Attached, 9. User?S List Should Be Attached With Satisfactory Report For The Last Three Years From Three Users With Contact Details.10. Firm Should Supply The Relevant Calibration Certificate For The Equipment From Nabl Accredited Lab., 11. Firm Will Have To Supply The Stabilizer If Required Along With The Equipment Free Of Cost12. Original Literature Of Equipment Should Be Submitted., 13.Firm Should Also Provide The Relevant Temperature Calibration Certificate For The Equipment From Any Nabl Accredited Lab. 14.User?S List Should Be Attached With Satisfactory Report For The Last Three Years From Three Users With Contact Details., 15. Electrical: The Equipment Should Be Able To Run On The Existing Electrical Provision. 16. Manufacturer Should Be Iso 13485 Certified., 17. Warranty 2 Yrs , Non-Invasive Hemoglobulin Meter Specification: 1. Hemoglobin ° Measurement Range: 7-17 G/Dl ° Precision (1 Sd): 1 G/Dlresolution: 0.1 G/Dl 2. Data Logger With Real Time And Date3. Measured Values Automatically Stored4. Multilingual Data Interface5. Warranty - 2 Yrs , Refrigerated Centrifuge Specification: For Nucleic Acid Or Protein Lysate Preparation And Pcr Reaction 1. Maximum Speed: 20,000 Rpm Or More., 2. Speed Control Accuracy: ± 10 Rpm. 3. Maximum Rcf: 80,000 G (Approx.), 4. Maximum Capacity:20Ml 5. Tube Volume Range: 1.5 Ml – 20Ml, 6. Set Temperature: 0 To 40°C 7. Ambient Temperature 10 To 35°C, 8. Cooling System: Cfc & Hcfc Free 9. Acceleration / Deceleration Profile: 10/10 Or More, 10. Programmability: 20 Or More With Step Run Facility, 11. Power: 210-240 Vac, 50 Hz, 30 A. 12. Machine Should Have Features Like Eye-Balancing Of Samples, Delayed Start/ Stop, Dual Display Of =Run‘ & =Set‘ Parameters, Data Entry Through Key Pad & Touch Pad, Rpm/Rcf Mode, Rotor Life Management Etc.13. Machine Should Accept Rotors Of Other Makes., 14. Should Be Fda Or Ce Or Bis Approved Product, 15. Warranty - 2 Yrs , Donor Couch Specification: 1. Based On Haemodynamic Principles To Allow Blood Volumes To Redistribute With Cushioned Surface For Donor Comfort., 2. Armrest Suitable For Phlebotomy And Better Blood Flow. 3. Automatic Adjustment Of Arm- Rest To Adjust Length More Than 50 Cm And Width Of 15 Cm To Set The Arm Position To The Donor?S Comfort With Adjustment Of Height Mandatory For The Equipment.4. Material Should Be Waterproof With Rounded Borders And Easy To Clean., 5. The Length Of The Couch Should Be 200 Cm To 215 Cm To Accommodate All Type Of Donors.6. Specially Designed For Comfort Of Donor And Phlebotomist, 7. Should Be Able To Accommodate Donor Weight Capacity Of 150Kg Or More., 8. Electronic Remote Adjustment For Height And Comfortable Sitting Position. 9. Provision To Shift The Donor?S Position From “Head High – Foot Low” To “Foot High- Head Low” Or Any Position In Between For Optimal Blood Collection., 10. Only One Button To Reach Shock Position: Head Low In Case Donor Reaction., 11. 2/3 Motors With Separate Control Through Remote For Positioning Of Couch., 12. Electric Motor Should Have Microprocessor Controlled Limit Switch And Safety Circuit. 16. Trolley (Ss 304, Having Atleast Two Shelves With Adjustable Height, Suitable Size) Should Be Provided With Each Couch For Keeping Blood Collection Monitor And Other Consumables., 17. Good Quality Couch Covers (Two Sets) To Be Provided Along With The Couches Including Handles., 18. Original Literature Of Equipment Should Be Submitted. 19. User?S List Should Be Attached With Satisfactory Report For The Last There Years From Three Users With Contact Details., 20. Bidder Have To Arrange Demonstration Of The Quoted Model (If Required) 21. Electrical: The Equipment Should Be Able To Run On The Existing Electrical Provision., 22. Manufacturer Should Be Iso 13485 Certified., 23. Should Be Supply With Suitable Stabilizer With Bis/Ce Mark. Accessories:- 24. Dust Cover -1, 25. Power Cable-1, 26. Additional Arm Rest (Pair)-01 Pair., 27. Remote Control-1 No, 28. Warranty - 2 Yrs , Automated Tube Stripperspecification: Motorized Metallic Roller & One Free Roller For Smooth Tube Strippingdesigned For Easy Manual Operation With Convenienceeasy To Use Hand Rollerportable Battery Pack, Backup 1000 Cyclesautomatically Strips Tube Once The Metallic Handle Is Pressed Uniform Radial Force Across The Tube-Prevents Abrupt Manual Pressureaudio Vishual Alarm For Over Load Protectionguiding Groove For Correct Tubing Position, Fed Through Rollerssuitable For All Commercially Available Blood Bags3. Warranty - 2 Yrs , Votex Mixer Specification: 1. Adjustable To 100 To 2500Rpm 2. Continuous And Intermittent Touch Control Modes 3. Heavy Cast Metal Base And Suction Cup To Assure Stability Prevent Walking 4. 220-230 Volts Ac, 50 Hz 5. Digital Display:Led6. Capacity Of 2-3 Kg And Orbit Of 35 Mm 7. Ce/Bis Approved8. Warranty - 2 Yrs , Magnetic Strirrer And Barspecification: 1. Digital Temperature Control With Max. Temperature At 380°C.2. Digital Speed Control With Max. Speed Up To 1500Rpm.3. High Resolution Lcd Displays For Actual Temperature And Speed.4. Brushless Dc Motorandmaintenance Free.5. Ceramic Plate For Chemical Resistance And Easy Clean. 6. Aluminium Cover With Ceramic Work Plate7. Hot Warning Sign If Temperature Is Above 50°C.8. Max. Stirring Quantity Of H2o At 5L. 9. External Temperature Control Is Available As Temperature Sensor Pt1000. 10. Warranty - 2 Yrs , Autoclave Specification: 1. Capacity 80-100L, 2. Sterilization Temperature 105-135 Deg C. 3. Pressure Gauge 1 To 1.5 Kg/Sq.Cm., 4. Safety Valve Releasing Pressure200kpa.5. Automatic Adjustable Working Pressure System., 6. Double Walled.7. Inside Boiler Made Of Stainless Steel & Outside Mild Steel Finished In Cream Enamel., 8. Radial Locking System Lid.9. The Panel Is Provided With On/Off Switch, Pressure Gauge, Steam Release Valve & Indicators To Show The Working Of Mains & Pressure Control System.10. Electrically Operated On 220V A/C With Stainless Steel Basket.11. Digital Temperature Controller With Inbuilt Timer That Will Cut Off The Heaters Automatically Afterlapse Of Pre Set Time At The Pre Set Temperature. 12. Microprocessor Based Pid Controller., 13. Height:600Mm. 14. Diameter Inside: 450Mm(24”X18”), 15. Manufacturer Should Be Iso 13485 Certified., 16. Warranty - 2 Yrs , Plasma Hemoglobinometer 1. Modified Azidemethemoglobin Method 2. Warranty - 2 Yrs , Millipore Waterplant1. Warranty - 2 Yrs , Microwave Oven1. Warranty - 2 Yrs , Thermal Temperature Monitor1. Infrared Thermometer2. Rechargeable3. Warranty - 2 Yrs
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 33
43.
Educational and Research Institute #9422255 Technical Bid
Rate Contract For Supply Of Lab.Consumable At Aiims Patna , Peg Mw – 3350 , 2 Mercapto Ethanol 1M , Hcl , Bromelain Enzymes 1 % W/V , Copper Sulphate (Anhydrous) Powder Cuso4 , Manual Plasma Expressor , Ansa , Di-Potassium Hydrogen Sulphate , Di-Sodium Hydrogen Orthophosphate , Di-Sodium Tetraborate , Eosin-Yellow , Hexane , Luxol Fast Blue , Medicated Liquid Antiseptic Solution For Cleaning Surfaces , Eppendroff Tube , Phenyl Hydrazine Chloride , Sodium Hydrosulphite , Sodium Hypochlorite Solution 5% , Toluidine Blue , Zinc Pellets , Ph Buffers For Ph 4, Ph 7, Ph 10 Or 9 , Bacterial Cultureplate (90 Mm) Holder , Bottle, Dropping With Pipette & Rubber Teat , Bottle, Dropping With Pipette & Rubber Teat , Conical Flask Short Neck, Pyrex Wide Mouth , Deep Freezer Plasma Storage Steel Rack (-40°C) , Deep Freezer Plasma Storage Steel Rack (-80°C) , Dropping Bottles 4 Ounce Brown Glass , Dropping Bottles 4 Ounce Brown Glass , Dropping Funnel , Erlenmayer Flask , Filter Paper (Whatman No 1) , Glass Rod , Khan Test Tube , Lancet (Round Needle) , Micro Slides With Spreader – Ground Edge Plain 76/26 , Nuclease Free Pcr Tubes (Round) , Perpex Microlitre Plate , Pvdf Membrane Roll , Sealing Film , Steelet 0.1Mm , Stop Watch With Alarm For Laboratory , Test Tube Borosilicate Graduated - 12Mmx75mm , Test Tube Borosilicate Graduated -12Mmx100mm , Test Tube Borosilicate Graduated - 18Mmx150mm , Test Tube Borosilicate Graduated -17X120mm , Test Tube Borosilicate Graduated -15Mm X 125Mm , Test Tube Borosilicate Graduated - 15X150mm , Test Tube Borosilicate Graduated - 20X150mm , Chrome Agar For Urinary Tract Infection , Double Strength Mac Conkey Broth For Water Testing , Vancomycin Powder , Viral Transport Media With Blocked Swab , Sterile Cotton Swab In Polypropylene Tube , Ria Vials , Filter Paper Imported Size 46X57cm , Slide Tray Plastic Cap. 20 Slide , Plastic Jar , Plastic Jar , Bottle Top Dispenser Fully Autoclavable 0.25-2.5Ml , Bottle Top Dispenser Fully Autoclavable 0.5-5Ml , Bottle Top Dispenser Fully Autoclavable 1-10Ml , Bottle Top Dispenser Fully Autoclavable 2.5-30Ml , Bottle Top Dispenser Fully Autoclavable 5-60Ml , Bottle Top Dispenser Fully Autoclavable 10-100Ml , Medical Waste Puncher Proof Sharp Container , Medical Waste Puncher Proof Sharp Container , Medical Waste Puncher Proof Sharp Container , Medical Waste Puncher Proof Sharp Container , Medical Waste Puncher Proof Sharp Container , Medical Waste Puncher Proof Sharp Container , Electrical Syringe Needle Destroyer , Patient Wrist Band Vinyl Mother Baby Id Band Locktag New Born Baby Adult Id Band , Pipette Filling Device , Bouffant Cap , Disposable Petridish 90Mm , Instrument Tray Stainless Steel 10 X 12 , Kidney Tray , Dressing Drum , Bar Code Lable , Bar Code Rebben , Haemocytometer , Haemometer , Rbc Pipette , Wbc Pipette , Haemoglobin Graduated Test Tube , Haemoglobin Pipette , Wafer (Tscd) , Biological Indicator For Autoclave , Negottee Chamber , Tissue Paper Roll , Hiv Iv Generation Rapid Kit (Tridot Method Of Membrane Enzyme Immuno Assay) , Hcv Iv Generation Card , 20% Human Albumin , Creatinine , Potassium Hydrogen Sulphate , Phenyl Phosphate Disodium Salt , Phenyl Hydrazine Hydrochloride , Sodium Nitrate , Di Sodium Tetraborate(Borax) , Galactose , Filter Paper Ordinary Sheet , 96 Well Pcr Plate , Amies Transport Media , Anaerobic Gas Pack , Arginine Powder (100 Gm) , Cedarwood Oil (Low Viscosity) , Cellobiose , Cellulose Acetate Syringe Filter In Individual Sterile Pack (0.45 ?) , Chrome Agar Candida , Colistin Powder , Brilliant Green Glucose Bile Broth (Powder) , Dnaase Agar Powder , Double Strength Mac Conkey Broth With Bromocresol Purple , Fosfomycin Disc (200 ?G) , Inositol , Mannitol Motility Media , Mellibiose , N 95 Mask (Niosh Approved) , Ornithine Powder , Lysine Powder , Raffinose , Robertson Cooked Meat Broth , Sda With Cycloheximide , Sterile Disc , Trehalose , Vancomycin Hydrochloride Powder , Viral Rna Extraction Kit (Membrane Or Column Based) , Vtm (Viral Transport Media With Flocked Nylon Swab) , Xylose , Dmso , 3, 3 - Dab , Sudan B Stain Kit , Toludine Blue , Plastic Disposable Apron , Safety Goggles , Atcc Staphylococcus Aureus - 25923 , Atcc Streptococcus Pneumoniae - 6305 , Antisera (Ehec 0157:H7) , Utility Tray , Plastic Tray Ordinary , Pipette Bulb , Test Tube Holder , Wire Mash (Gauge) , Pipette Controller , Micro Centrifuge Tube , Condenser Glass (24X29) , Micro Centrifuge Tube Box , Flat Bottom Flask Glass , Adapter Recovery Bend With Sloping End , Clampstwo Fingerzinc Pressure , Tongs For Flask , Tongs For Crucible , Watch Glass , Magnetic Stirrer , Autoclavable Transparent Plastic Bags , Freezer Thermometer , Glass Marking Colour Pencil (White) , Glass Slide Marking Marker (Red). , Glass Slide Marking Marker (Green). , Diamond Marker Pencil , 5Ml Capped Falcon Tubes , Hbsag Antibody , Hcv Antibody , Centrifuge Tube Glass Plastic , Glass Tissue Homogeniser , Spatula (S.S) , Spatula Poly , Cotton Swabs , Filter Paper No. 1 (12.5Cm) , Filter Paper (11 Cm) Ordinary , Funnel Poly , Micropipette Tips Box , Micropipette Tips Box , Polycarbonate Cryboxes , Polycarbonate Cryboxes , Retort Stand , Retort Stand , Slide Box , Slide Box , Slide Box , Test Tube Holder , Test Tube Holder , Test Tube Holder , Test Tube Holder , Test Tube Holder , Bp Apparatus , Cryo Vials , Micro Centrifuge Tube , Micro Centrifuge Tube , Micro Centrifuge Tubes , Rapid Ict For Detection Of Filarial Antigen (Ce & Ivd Approved) , Rapid Test To Detecting Filarial Antigen (Ce & Ivd Approved) , Scrub Typhus (Ab) , Filarial Antigen , H. Pylori Antibody , Glucostrip (Gluco Card) , Anti Sera A , Anti Sera B , Anti Sera D , Bovine Albumin 22% , G6pdkit , Rapid Plasma Reagin Testing Kit , Tuberculin Rapid Kits , Widal (Slide And Tube) , Igg Antibody Kit For Sars-Cov2 , Il - 6 (Quality Control) 1*7Ml (Level-1) 1*7Ml (Level-2) 1*7Ml (Level-3) , Il - 6 Kit For Advia Centaur Xp/Xpt (Siemens) , Multistix 10Sg , Colchicine , Dna Se (Molecular Biology Grade) , Giemsa Stain Powder , Ripa Buffer , Alkaline Phosphatase , Annexin-V-Fitc Detection Kit , Bca Protein Assay Kit , Bovine Serum Albumin Solution 20 Mg/Ml In H2o, Protease Free, For Molecular Biology , Growth Factors-Ngf , Lif , Egf , Hgf , Pdgf , Hrp Labeled Secondary Antibodies Of Different Species , Mitotracker Red , Propidium Iodide , Rnaase-A (Molecular Biology Grade) , Trizol Reagent , Trypan Blue For Molecular Biology , Filter Tips 1000Ul (10*24) , Anti-Rabbit Igg Alexa Fluorphore 350 Nm Blue , Ar Antibody , Beta Catenin Antibody , Cd 41 , Cd 51 , Cxcl - 10 , Cxcl - 12 , Cxcl - 14 , Erg Antibody , Her2 (Erb B2) Fitc For Fish , Idh2 Antibody , Med 12 Antibody , Monoclonal Immunoglobin / Ap , Monoclonal Immunoglobulin / Biotin , Sv 40 Antibody , Tau Antibody , Ascorbic Acid , Bovine Albumin (Serum) , Dinitrosalicylic Acid 3 5 , Folic Acid Vitamin M , Haemetoxyllin-Harris , Methanol , Mueller Hinton Broth , Oil-Red-O Stain , Paraffin Wax (Soft & Hard) , Sodium Bicarbonate (Cell Culture Tested) , Thiosulphate Citrate Bile Salt Sucrose Agar Powder , Albumin , Depc Treated Water , Diethyl Pyrocarbonate (Depc) , Dntps Mix (10 Mm) , Mops, Sodium Salt , Potassium Acetate, Crystal (Molecular Biology Grade) , Taq Dna Polymerase (For Molecular Biology Work ) (For Pcr Reactions) , Trizma Base , Dtt (1,4-Dithiothreitol) , Pcr Master Mix , Hugh & Leifsons Oxidative Fermentative Media (Of Media) , Arabinose , Amino Acid Kit , Brij 35 , Chromotrope 2 R (10G) , Dapi (For Nucleus Staining) 10 Mg , N- Butanol , 1- Napthol , Acetic Acid Glacial , Acetic Acid Glacial , Acetone , Acetone , Acridine Orange , Activate Charcoal , Activate Charcoal , Agar Agar Powder , Albert Stain A,B , Alcohal Based Hand Sanitiser , Aluminium Chloride , Aluminium Sulphate , Ammonia Solution , Ammonia Solution , Ammonia Solution , Ammonia Solution , Ammonium Oxalate , Ammonium Thiocynate , Ammonium Per Sulphate , Ammonium Per Sulphate , Ammonium Sulphate , Ammonium Sulphate , Ammonium Sulphate , Andrades Indicator , Anhydrous Sodium Sulphate , Aniline Blue , Ascorbic Acid , Barium Carbonate , Barium Carbonate , Barium Chloride (Colourless Rhombic Srystal) , Barium Nitrate , Barium Nitrate , Beta Naphthol , Beta Naphthol , Bile Salt , Bis-Acrylamide , Boric Acid , Brilliant Crystal Blue , Brilliant Crystal Blue , Brilliant Green , Brilliant Green , Bromocresol Green , Bromophenol Blue , Brucine , Buffer Solution (Ph10.0), (Ph4.0), (Ph7.0) , Calcium Chloride , Carbolfuchsin , Carmine , Cedarwood Oil , Cellulose Power , Cellulose Power , Cerric Ammonium Sulphate , Chloroform , Chloroform , Citric Acid , Cled Agar , Congored Statin , Congored Statin , Crystal Violet Solution , Cupric Acetate , Cupric Sulphate , Cyclo Hexane , Dextrose Powder , Di Ethylamine , Di Phenyl Carbazone , Di Potassium Hydrogen Phosphate , Di-Sodium Hydrogen Orthophosphate (Dehydrate) , Di-Ammonium Oxalate , Diethyl Ether , Diphenylamine , Diphenylbenzidine , Dithizone , Dpx Mounting Fluid , Edta , Edta , Eosin-Aquous (Y) , Eosin-Aquous (Y) , Eosine-Methyline Blue , Ethidium Bromide , Ethidium Bromide , Ethyl Acetate , Ferric Chloride (Anhydrous) , Formaldehyde , Fructose , Gelatin Powder , Giemsa Stain , Giemsa Stain , Giemsa Stain Solution , Giemsa Stain Solution , Glucose , Glycerol , Glycogen , Grams Lodine , Grams Lodine , Haematoxylin , Haemetoxyllin-Ehrlich , Haemetoxyllin-Meyer , Heparin Sodium Salt (Cell Culture Tested) , Hydrochlorid Acid , Hydrochlorid Acid , Hydrochlorid Acid , Hydrogen P[Eroxide 50%, 3% , Hydroquinone , Hydroxylamine Hydrochloride , Immersion Oil (Cedar Wood) , Iodine , Isopropyl Alcohol 70%, 99% , Isopropyl Alcohol 70%, 99% , Kovacs Indole Reagent , Lactose Monohydrate Powder , Lead Acetate (Sugar Of Lead; White Crystal) , Leishman Stain , Leishman Stain Power , Liquid Paraffin , Lithium Carbonate , Litmus Blue Paper , Litmus Red Paper , L-Lysine , Loefflers Serum Slope , L-Phenylalanine , L-Proline , Magnesium Chloride , Mallorys Stain , Maltose , Manganese Dioxide , Mannitol , Mercuric Chloride , Mercuric Chloride , Mercuric Oxide , Methyl Benzoate , Methyl Orange , Methyl Red Reagent , Methylenc Blue , Methylene Blue Aqueous , Methylene Blue Loefflers , Molybdic Acid , Nigrosin Stain , Ninhydrin , Nitric Acid , Nitric Acid , Orcinol , Orthophosphoric Acid , Osmium Tetra Oxide , Oxalic Acid , Palladium Chloride , Paraffin Liquid Light , P-Dimethyl Amino Benzaldehyde , P-Dimethyl Aminobenylidine (Rhodanine) , Petroleum Ether , Ph Paper Wide Range (1-14) , Phenol (Crystal Ar) , Phenol Red Powder , Phenol Red Sodium Salt , Phloroglucinol , Phosphoric Acid , Picric Acid , Poncaeu , Potasium Fluoride , Potassium Hydroxide , Potassium Carbonate , Potassium Chloride , Potassium Chromate , Potassium Di Hyd. Phosphate , Potassium Dichromate , Potassium Dihydrogen Phosphate Powder , Potassium Ditydrogenortho Phosphate Monobasic , Potassium Ferro Cyanide , Potassium Fluoride , Potassium Hydroxide Pellets , Potassium Iodide , Potassium Nitrate , Potassium Nitrate , Potassium Oxalate , Potassium Permangnate , Potassium Sodium Tartrate , Potassium Tellurite 1% , Pyridine , Pyrogallol , Safranine , Salicylic Acid , Silver Nitrate , Sodium Acetate , Sodium Azide , Sodium Bisulphite , Sodium Carbonate (Anhydrous) , Sodium Chloride , Sodium Fluoride , Sodium Hydrogen Carbonate , Sodium Hydroxide Flakes , Sodium Hydroxide Pellets , Sodium Hypochlorite , Sodium Hyrdoxide , Sodium Lauryl Sulphate , Sodium Nitrite , Sodium Nitropusside , Sodium Sulphite , Sodium Thiosulphate , Sodium Tungstate , Sorbitol 70% , Stannous Chloride , Starch , Stearic Acid , Succinic Acid , Sucrose Powder , Sudan Black , Sudan Black , Sulphosalicylic Acid-5 , Sulphur Powder , Sulphuric Acid , Tannic Acid , Temed , Thiosemicarbazide , Toluene , Tris Hcl , Tri-Sodium Citrate , Trisodium Phosphate , Trypsin 0.25% Solution 1X , Trypsin 1:250 Powder Porcine , Tryptone , Tween 20 , Urea Powder , Urea Powder , Uric Acid Powder , Vanillin , Xylene , Xylene Sulpher Free , Zinc Chloride , Zinc Dust , Zinc Nitrate , Acrylamide , Albumin , Ammonium Acetate , Ammonium Chloride , Commassie Brilliant Blue R-250 , Dihydrogen Potassium Phosphate , Dimethyl Sulfoxide For Molecular Biology, =99.9% , Harris Hematoxyllin , Heparin , Hepes, Sodium Salt , Iso Amyl Alcohol , Magnesium Sulfate , N,N-Dimethylformamide For Molecular Biology,=99% , Potassium Phosphate, Dibasic, Powder , Potassium Sulfate , Sodium Phosphate Dibasic , Sodium Phosphate Monobasic , Sodium Sulphate Anhydrous , Sucrose , Triton™ X-100 For Molecular Biology , 3.8% Tri Sodium Citrate , 40% Formaldehyde , Acid Fuchsin , Aluminium Hydroxide , Aluminium Potassium Alum , Basic Fuchsin , Benedicts Reagent , Cresyl Violet , Dextrin , Diastase , Ea-50 , Hematein , May Grunwalds Solution Modified , Methylene Stain , Neutral Red , Og-6 , Paraffin Wax With Cerasin , Periodic Acid , Phosphomolybdic Acid , Potassium Acetate , Propanol , Rbc Diluting Fluid , Sodium Meta Bisulfate , Trichloroacetic Acid , Tris Buffer , Wbc Diluting Fluid , Anaeroabic Jar Made Of Hard Plastic (Polycarbonate) With Metal Lid(Big) , Absorbent Cotton Rolls (Big) , Alpha Naphthylamine , Amphotericin B (50 Mcg) Antibiotic Discs , Bacitracin Antibiotic Discs , Bisic Fuchsin Bacterial Grade , Benzioc Acid , Bird Seed Agar , Cefipime (30 Mcg) Antibiotic Discs , Cefoperazone Sulbactam , Ceftazidimeclavulanic Acid (30/10 Mcg) Antibiotic Discs , Clotrimazole (10 Mcg) Antibiotic Discs , Colcemid Solution , Colchicine Solution , Crystal Violet Powder , Crystal Violet Powder , Decarboxylase Readymade Medium (Himedia) , Defibrinated Sheep Blood Agar , Dna Isolation Kit , Dna Ladder (50Bp) , Dna Ladder (50Bp) , Eosin , Ethanol (Ar) , Eucalyptus Oil , Fetal Bovine Serum , Furazolidone 50 Mcg Antibiotic Discs , Gallocyanine , India Ink Solution , Isopropyl Alcohol 70%, 99% , L-Glutamine (From Non-Animal Source) (Cell Culture Tested) , L-Glutamine200mm Solution , L-Glutamine-Penicillin-Streptomycin Solution , Light Green , Lowenstein Jensen Media Slant , Mccoys 5A Medium (For Suspension Culture) , Mcfarland Standard Set , Medium 199 , Mrvp Broth , Nessler Reagent , Netilmicin (30 Mcg) Antibiotic Discs , Novobiocin (30 Mcg) Antibiotic Discs , Oil Red , Optochin Disc , Oxidation-Fermentation Agar , Pha-M Solution , Phosphate Buffered Saline, Ph 7.2 , Resorcinol , Rhodamine B Spray , Silver Nitrate , Sodium Bicarbonate Solution 7.5% , Sulphuric Acid , Tigecycline (15 Mcg) Antibiotic Discs , Tris Base , Vaseline , Beta Mercaptoethanol , Cdna Synthesis Kit (50Rxn) , Cdna Synthesis Kit (50Rxn) , Collagenase , Dithioerythritol (1,4-Dithioerythritol), Molecular Biology Grade =99.9% , Dmem (Dulbeccos Modified Eagle Medium) (Cell Culture Grade) , Dna Molecular Weight Marker Dna Ladder (100Bp)/- 100 Micro Liter , Dna Molecular Weight Marker Dna Ladder (100Bp)/- 100 Micro Liter , Hepes Buffer (1 M) (For Cell Culture) Molecular Biology Grade , Rna Isolation Kit-Molecular Biology Grade , Sybr ® Green Qpcr Ready Mix™ , Variable Single Channel Micropipette (5 To 50,10 To 100,100 To 1000) , Rpmi-1640 , Np-40 , Nuclease Free Water (Molecular Biology Grade) , Pre Stained Protein Maker For Western Blotting , Pvdf Membranes For Western Blotting Transfer , Acetonitrile (Hplc Grade) , Novobiocin 30 Mcg ( Antimicrobial Impregnated Discs) , Escherichia Coli (25922) , K.Pneumoniae Atcc Baa 1705 , Candida Albicans Atcc 90028 , Candida Parapsilosis Atcc 22019 , Candida Tropicaeis Atcc 750 , Enterococcus Faecalis Atcc 51299 , Atcc Candida Albicans - 10231 , Atcc E. Coli - 25922 , Atcc Enterococcus - 29212 , Atcc Klebsiella Pneumoniae - 13883 , Atcc Pseudomonas Areuginosa - 27853 , Atcc Staphylococcus Aureus - 25923 & 29213 , Cholesterol , Geobacillus Stearothermophilis Ampoules For Autoclave. * Should Be Complaint To En/Iso 11138-2:2006 & En/Iso 11138-1:2006.* Should Be Complaint To En/Iso 11138-2:2006 & En/Iso 11138-1:2006.* Ansi/Aami/Iso 11138-1:2006 & 11138-2:2006. *Every Box Should Contain Quality Assurance Certificate With Mention Of Spore Population & D-Value. , Methanol 70 Percent , Ph Paper(2-4.5) , Ph Paper(6.5-9.0) , Potash Alum , Real Time Pcr Master Mix (One Step) * Master Mix With Dntps And Enzymes Must Be In Two Separate Containers. * Master Mix Should Be In A Amber Colouredbottle To Make It Stay Protected From Light. * Mastermix Must Be In 2X Concentration.* Enzyme Must Be In 25 X Concentration. * Rox And Dye Enhancer Must Be Added. , Disposable Jamshidi Bone Marrow Biopsy Needles , Acd Vial , Blood Lancet , Disposable Bone Marrow Biopsy Needle (Pediatric & Adult) , Heparinised Syringe , Lancet For Blood Collection , Lithium Heparin Syringe , Urine Kit For Culture & Sensitivity Testing , Vacutainerholders , Vacutainer Safety-Lock Blood Collection Set , Bioharzard Disposable Bags & Holder , Paraffin Roll 4X125 , Variable Multi-Channel Micropipette , Fixed Single Channel Micropipette , Carboard Cryogenic Vial Boxes , Carboard Cryogenic Vial Boxes , Cell Culture 24-Wellx3.4Ml , Cell Culture Multi-Well Plate With Lid 6-Well , Cryo Gloves , Cryo Tags , Cryogenic Vials , Cryogenic Vials , Cryotubes(Storage Vial) , Culture Flasks 75 Cm , Draining Tray , Gel Scooper , Ice Tray , Ice Tray , Jerrican , Jerrican , Jerrican , Magnetic Retriver (Plastic) , Micro Pipette Fixed/ Variable , Micro Pipette Fixed/ Variable , Micro Pipette Fixed/ Variable , Micro Tube Racks , Micro Tube Racks , Micro Tube Racks , Micro Tube Racks , Micro Tube Racks , Microcentrifuge Tubes Racks , Microcentrifuge Tubes (Autoclavable) , Microcentrifuge Tubes (Autoclavable) , Optical Flat 8-Cap Strip , Parafilm Sealing Film , Parafilm Sealing Film , Parafilm With Dispenser , Pcr Tips , Pcr Transfer Tray , Petri Dish(Poly) , Petri Dish(Poly) , Petri Dish(Poly) , Petri Dish(Poly) , Plastic Dustbins , Plastic Staining Tray , Plastic Staining Tray , Polycarbonate Cryboxes , Polycarbonate Cryboxes , Polygrid Microtube Holder , Reversible Pcr Racks , Reversible Racks With Cover , Sample Container , Staining Box , Staining Box , Stopcocks , Storage Boxes , Storage Boxes , Storage Boxes , Storage Boxes , Storage Boxes , Test Tube Plastic Basket (Autoclavable) , Test Tube Plastic Basket (Autoclavable) , Test Tube Plastic Basket (Autoclavable) , Tissue Culture Flasks , Tissue Culture Flasks , Tissue Culture Flasks , Tough Tags , Tough Tags , Tough Tags , Tough Tags , Universal Cobi Rack , Universal Cobi Rack , Universal Graduated Tips (Without Box) , Universal Graduated Tips (Without Box) , Universal Graduated Tips (Without Box) , Universal Graduated Tips (Without Box) , Urine Collection Containers (Sterile) , Wide Mouthed Regentbottle(Amber) , Wide Mouthed Regentbottle(Amber) , Wide Mouthed Regentbottle(Amber) , Wire Racks For Centrifuge Tubes , Wire Racks For Centrifuge Tubes , Plastic Pasteurpipettes With Teats (3Ml) , Plastic Pasteurpipettes With Teats (3Ml) , Test Tube Trey (Plastic)360X310x130mm , Optical Adhesive Film For 96 Well Pcr Plate Compatible With Quantstudio 5 Dx Real Time Pcr Machine , Plastic Pasteur Pipette With Teats 3Ml , Universal Graduated Filtered Tips With Box 1000 Ul , Universal Graduated Filtered Tips With Box 200 Ul , Universal Graduated Tip With Box 1000Ul , Universal Graduated Tip With Box 200Ul , Mini Spin 12 Places , Vortex , Long 1000 Microliter Filter Tips With Box , Cryochill Vial , Microcentrifuge Tips , Microcentrifuge Tips , Microcentrifuge Tips , Optical Adhesive Film For 96 Well Plates Compatible To Quantstudio 5Dx Real Time Pcr Machine , Adhesive Film For 96 Well Plates Compatible To Cfx 96 Biorad Real Time Pcr Machine , Blood Collection Needle 22 Gauge With Cap And Safety Lock For Evacuated Tube , Esr Tube Sodium Citrate 3.8% Volume 1.6Ml , Vacutainer For Pt(2.7Ml) , Yellow Caped (Gel) Serum Separator Tube , Clot Aviator For Serum (Without Gel) 4Ml, 13X75mm (Red Cap) , Flouride Tube 2Ml, 13X75 Mm (Grey Cap) , C4d Antibody , Calcitonin Antibody , Calponin , Cd 163 , Cd 19 , Cd 61 , Cd 68 , Cdx 2 , Cmv Antibody , Cyclin D1 , D2 - 40 Antibody , Dab Enhancer (110 Ml) , Fascin , Fli 1 Antibody , Fsh Antibody , Gfap Antibody , Glypican 3 , Growth Hormone Antibody , Hbcag Antibody , Hbv , H-Caldesmon , Idh1 Antibody , Lh Antibody , Mmp - 9 , Muc 5 , Nkx 2.2 , Oct 4 Antibody , Pap Pen , Prolactin Antibody , Rba Hu Calcitonin Antibody , Rba Hu S100antibody , Sox - 10 , Stat 6 , Tubulin , Vegf , Vwf , Hpv , Dark Glasses , Universal Precaution Set , Agar Agar Powder , Agarose Powder , Disinfectant Handwash , Disinfectants For Medical Equipments , Pcr Buffer , Individual Pcr Tubes Strip, Clear , Pcr Tubes , Pcr Tubes , Pcr Tubes , 8 Tube Pcr Strip & Cap Compatible To Biorad Cfx96 , 8 Tube Strip & Cap Compatible To Biorad Cfx96 , 96 Well Pcr Plate & Sealer Compatible To Biorad Cfx96 , 96 Well Pcr Plate Compatible To Biorad Cfx96 , Iui Kit , Rnase Zap , Sealer Compatible To Biorad Cfx96 , Sperm Wash 125Ml , Viral Rna Extraction Mini Kit Compatible To Qia Cube Connect Machine (1 Box = 250 Reactions) , Dry Bath 24 Places , Qiaamp Rna/Dna Kit 250 Test , Coulmn Based Virus Rna/Dna Extraction , 96 Well Plates Compatible To Quantstudio 5Dx Real Time Pcr Machine , 96 Well Plates Compatible To Cfx96 Biorad Real Time Pcr Machine , Bcr-Abl1 Real Time Quantitative Assay Kit Which Should Include Standards, Controls, Cdna, Master Mix Qpcr Reagents Standardized To Who Is For P210, P190, P230 Detection In Single Kit Upto Log 5 It Should Be Highly Sensitive To Deep Molecular Response Reporting , Gel Puncher (For Electrophoresis) , Amikacin (30 Mcg) Antibiotic Discs , Ammonium Molybdate , Amoxicillin Clavulanate (20/10 Mcg) Antibiotic Discs , Ampicillin (10 Micg) Antibiotic Discs , Ampicillin Sulbactam 10/10 Mcg Antibiotic Discs , Azithromycin (15 Mcg) Antibiotic Discs , Aztreonam (30 Mcg) Antibiotic Discs , Bile Esculin Agar Powder , Blood Agar Base , Brain Heart Infusion Broth , Brain Heart Infusion Broth , C.L.E.D. Agar With Bromothymol Blue , Cefixime (5 Mcg) Antibiotic Discs , Cefotaxime (30 Mcg) Antibiotic Discs , Cefoxitin (30 Mcg) Antibiotic Discs , Cefazidime (30 Mcg) Antibiotic Discs , Ceftriaxone (30 Mcg) Antibiotic Discs , Cefuroxime (30 Mcg) Antibiotic Discs , Chloramphenicol (30 Mcg) Antibiotifc Discs , Christensen Urea Agar Base , Christensen Urea Agar Base , Ciprofloxacin 5 Mcg Antibiotic Discs , Clindamycin 2 Mcg Antibiotic Discs , Colistin (10 Mcg) Antibiotic Discs , Cotrimoxazole (23.75/1.25)Mcg Antibiotic Discs , Detergent Cleaner For Medical Equipments , Erythromycin (15 Mcg). Antibiotic Discs , Ferrous Sulphate , Fluconazole (25 Mcg). Antibiotic Discs , Gentamicin (10,300 Mcg) Antibiotic Discs , Haemetoxyllin-Delafield , High Level Gentamicin 120 Mcg Antibiotic Discs , Imipenem (10 Mcg) Antibiotic Discs , Lactophenol Cotton Blue Stain , Levofloxacin (5 Mcg) Antibiotic Discs , Linezolid (30 Mcg) Antibiotic Discs , Lowenstein Jensen Media Slant , Lugols Iodine , Mac Conkey Agar , Mac Conkey Agar , Mannitol Salt Agar , Mercuric Sulphate , Meropenem 10Mcg Antibiotic Discs , Methyl Red , Mueller Hinton Agar , Mueller Hinton Agar , N-Acetyl L-Cystienc , Nalidixic Acid (30 Mcg) Antibiotic Discs , Nitrofurantoin (300 Mcg) Antibiotic Discs , Norfloxacin (10 Mcg) Antibiotic Discs , Nutrient Agar , Nutrient Agar , Nutrient Broth , Nutrient Broth , Ofloxacin (5 Mcg) Antibiotic Discs , Onpg Discs , Oxidase Disc , Peptone Water Powder , Peptone Water Powder , Phenophthalein , Phenylalanine Agar , Phosphotungstic Acid , Piperacillin Tazobactam 100/10 Mcg Antiviotic Discs , P-Nitro Benzyl Pyridine , Polymyxin B (300 Mcg) Antibiotic Discs , Potassium Ferri Cyanide , Potassium Iodide , Potato Dextrose Agar , Rifampicin (5 Mcg) Antibiotic Discs , Sabouraud Dextrose Agar , Simmons Citrate Agar Powder , Simmons Citrate Agar Powder , Sodium Di Hydrogen Phosphate , Sodium Lauryl Sulphate , Sulphanilic Acid , Tellurite Blood Agar Base , Tetracycline 30 Mcg Antibiotic Discs , Triple Sugar Iron Agar Powder , Triple Sugar Iron Agar Powder , Tsi Agar , Vancomycin (30 Mcg) Antibiotic Discs , Voriconazole (1 Mcg). Antibiotic Discs , Xylose Lysine Deoxycholate Agar , Amido Black , Commassie Brilliant Blue R-250 , Glaxial Acetic Acid= 99.85% , Tris Hydrochloride , Harris Hematoxylin , Amikacin 30 Mcg ( Antimicrobial Impregnated Discs) , Cefotaxime 30 Mcg ( Antimicrobial Impregnated Discs) , Cefoxitin 30 Mcg( Antimicrobial Impregnated Discs) , Ceftazidime 30 Mcg ( Antimicrobial Impregnated Discs) , Clindamycin 2 Mcg ( Antimicrobial Impregnated Discs) , Colistin 10 Mcg ( Antimicrobial Impregnated Discs) , Cotrimoxazole (23.75/1.25 Mcg) ( Antimicrobial Impregnated Discs) , Erythromycin 15 Mcg ( Antimicrobial Impregnated Discs) , Gentamicin 10 Mcg ( Antimicrobial Impregnated Discs) , Imipenam 10 Mcg ( Antimicrobial Impregnated Discs) , Labolene 2.5 Ltr , Linezolid 30 Mcg ( Antimicrobial Impregnated Discs) , Norfloxacin 10 Mcg ( Antimicrobial Impregnated Discs) , Ofloxacin 5 Mcg ( Antimicrobial Impregnated Discs) , Oxidase Disc ( Antimicrobial Impregnated Discs) , Peperacillin Tazobactum ( Antimicrobial Impregnated Discs) , Hematoxylin Powder , Rice Extract Agar , Chrom Agar For Candida , 4-Amino Antipyrine , Alkaline Peptone Water , Bowie Dick Test Pack , Chrome Agar Uti , Di Acetyl Monoxime , Dulcitol , Ea - 50 Stain , Glucose Azide Broth (Powder) , Glycerine , Orange G6 Stain , Orcin , Proline , Teicoplanin Disc (30 ?G) , 1% Acetic Acid Diluted Spray , 1% Toludine Blue Dye , 5’Ema For Flow Cytometry , Absolute Alcohal 99% , Acd (100Ml/50Ml) Infusion Solution , Acetycholinesterase Antibody For Ihc , Acetyl Choline Esterase Histochemistry (Ache) Stain Kit , Ache Enzy. Ab For Ihc , Acid Citrate Dextrose Solution , Acid Elution Kit , Acne Uv Gel Spf30 , Acp , Acriflavine Schiff Reagent (2 Unit) , Adsorption Kit , Alcian Yellow Tolulidine Blue Stain Kit , Aldolase , Aldolase (5X20) , Amino Acid Decarboxylation Media Control, Lysine, Ornithine, Arginine , Ammonia Calibrator , Ammonium Hydroxide , Amnio Max ™ C-100 , Amnio Max ™-Ii Complete Medium , Amphetamines / Ecstasy , Anaemia Control (Ferritin, Vitamin B12, Folate Etc.) , Anaemia Control (Ferritin, Vitamin B12, Folate Etc.) , Anca Kit By Ifa (30 Test) , Angiotensin Converting Enzayme (Ace) Kit For Use In Au Series , Ano-1 , Anterior Chamber Iol , Anti Ebp 50 Antibody , Anti H3k27 M Antibody , Anti-Rabbit Igg Alexa Fluorphore 488 Nm Green , Anti-Rabbit Igg Alexa Fluorphore 594 Nm Red , Apo A1 , Apo A1 & B Calibrator , Apo B , Aptt Regeant , Atcc Aspergillus Flavus 204304 , Atcc Enterobacter Cloacae Baa 2468 , B-27 Supplement Minus Ao (50X), Liquid , Barbitone , Barbiturates , Bench Top Dispensing Bins (Neon Green) , Benzidine Powder , Benzodiazepines , Benzodiazepines , Bile Acids (Hitachi) , Bilirubin (Liquid) , Biotin Blocking System , Blue Cap Vacutainer (Sodium Citrate 3.2%) 0.9Ml , Blue Cap Vacutainer (Sodium Citrate 3.2%) 1.0 Ml , Brd U (Bromo Deoxy Uridine) , Bromine , Bromine Ampule , Bss Plus (Balanced Salt Solution) , Buccal Tube (Right And Left) Bondable Mbt Prescription , Budecort Mdi , Ca - 1X , Ca-9 , Cal D 2/Pk , Calcium , Calcium Ocpc , Canca Fitc , Carbogen (Rpr) , Carbon Tetrachloride , Catechu Extract , Cd 303 , Cd 41 For Flow Cytometry , Cd 61 For Flow Cytometry , Cd-16 , Cd-200 , Cd-40 , Cd4pe-Cy7 (Ruo) , Ceftazidime Avaibactum Antibiotic Disc 10/4 Mcg , Cellophane Membrane Bag (For Toxicology) , Cellophane Tape , Centrifuge Bottle Rack (250Ml) , Chlorhexidine Powder For Antimicrobial Susceptibility Testing , Chloride , Cholinesterase (Butyryl) , Chroma Pct Kit With Buffer 10T , Chroma Tn - I Plus With Buffer 25T , Chrome-Alum (10Mg/Pack ) , Cinchonine , Ciprofloxacin 2 Mcg ( Antimicrobial Impregnated Discs) , Citrate Buffer Solution , Clean Universal Detergent , Co2 Total , Cocaine , Coe Pak (Periodontal Dressing) (1X90 Gm Base 1X90 Gm Catalyst) , Collagenase , Common Household Bleach , Condensers (Glassware Used In Distillation Process) (300Mm) , Copper (Liquid) , Copper Wire (For Toxicology) , Core Tdm Multi-Calibrator , Crp (Slide) , Cyclin D1 For Flow Cytometry , Data Printer Rol Eto , Dau High Multi-Drug Calibrator , Dau Intermediate Multi-Drug Calibrator , Dau Primary Cut-Off Multi-Drug Calibrator , Dau Secondary Cut-Off Multi-Drug Calibrator , Defibrinated Sheep Blood In Ready-To-Use , Desmoglein-1 (Iif) , Desmoglein-3 (Iif) , Desnet Solution (Disinfectant, 2%) , Dextrin Powder For Corynebacterium Diphtheriae , Dg Gel Coombs Card , Dg Gel Solution 100Ml (Pkt Of 2 Vials) , Di-Amino Benzedine (Dab) Kit (2 Nos) , Diamino Biphenyl 4-4 , Dihydro Rhodamine , Diphtheria Virulence Supplement A And B , Di-Sodium Hydrogen Sulphate , Dna Fragmentation Kit , Docetaxel Concentrate 80Mg With Solvent , Document Labels Roll (Vh202) , Document Lable 3 Lines Eto (550) , Double Mouth Bottle , Double Mouth Bottle , Double Mouth Bottle , Dry Cobalt Acetate , Duoline Mdi , Duraclone B27 , Dystrophin Antibody For Ihc , E-Check Control (L.N.H) , Eddp , Edta Vacutainer (3Ml) With Vacuum , Eeg Electrode , Eeg Gally (10-20 Jelly) , Elastin Stain Kit , Elf 97 Endogenous Phosphatase Detection Kit , Elisa Kit For Rotavirus Antigen , Elisa Plates (Round Bottom) (6,12,24,96 Wells) , Emv , Eosin- Alcoholic , Er Beta , Ethylene Glycol-Bis , F-12 Nutrient Mixture , Factor Xiia Antibody , Ferrous Hydroxide , Ferrous Sulphide , Fibreglass Reinforced Peg Racks , Fibrinogen Assay Kit , Ficin Enzymes 1 % W/V , Filarial Rapid Immunochromatographic Test Kit , Fistula Needle , Fitc Anti - Iga Nexes Reagent, Ventana , Flaer For Pnh Study , Flasks Conical Without Rim (750) , Flexometlic Tube 7.5 , Flocked Nylon Swab With Plastic Stick , G6pd Control , G6p-Dh , Gas Cartage Eto , Gel Clot Activator , Gh (Growth Hormone) , Glass Bottle Wide Mouth , Glass Candle Jar With Lid , Glass Pipe Heat Foldable , Glassware Cleaning Solution , Glucagon , Glucose - Stat , Glutaraldehyde , Gms Stain Kit , Gomori Stain , Green Cap Vacutainer (Heparin Containing):200-400 ?L , Grey Cap Vacutainer(Fluoride Vacutainer):400-600 ?L , Group A - (S. Dysentriae) - Polyclonal , Group B - (S.Flexneri-Polyclonal) , Group C - (S. Boydii) - Polyclonal , Group D - (S. Soneii) - Polyclonal , Guaiacum (2 Bottles) , H3k27m Antibody , Halles Colloidal Iron Stain Kit , Hbdh , Hela Cell Line Coated Slides For Immunoassays , Helix Test Eo Pcd , Hematopoietic Stem Cell Enumeration Kit , Hemocue Microcuvettes , Hemocue Microcuvettes 301 (Box Of 4 Pkt) , Hemolysing Reagent(For Hba1c Estimation) , High –Low Temperature Tapes , High Temperature Gloves , Hippurate , Hoechst-33258 =98%(Tlc) , Hsv , Hydrophobic Barrier Pen For Ihc (Pap Pens) , Hyperfilm-Ecl Films , Icmr Approved Rapid Antigen Detection Kit , Idh-2 Antibody For Ihc , Igm / Igg Antibody Rapid Test Kit , Igm Against Orientia Tsutsugamushi Elisa Kit , Inaba , Indeflator , Indocyanin Green Dye , Inhibitar Aassy Regeant For Factor Viii , Inj. Water For Reconstitution , Injection Vial , Ink Blue Color , Insulin Syringe , Iodoplatinate Reagent , Isopentane , Jenner Wright Giemsa Stain Kit , Kalazar (Rk-39) , Kerenchtrot , Kymograph Paper , Latex Agglutination Kit For Cryptococcus Ag , Ld Pyruvate -> Lactate , Leather Stroops-2 (For Histopathology) , Legionella Supplement A And B , Lens Cleaner For 125Ml Microscope , Lens Cleaner For Microscope , Leupeptin , Ligroin Solvent , Liner Bag For Eto , Lipase Uv , Lister Perimeter Chart , Lithium Heparin , Low Lonic Strength Solution/Liss , Lysine Coated Glass Slides(75Mmx22mm) (100/Pack) , Lyso Tracker Red Dnd-99 (L 7529) , Marsh Apparatus (For Arsenic Detection In Toxicology) , Marsh Tube (For Arsenic Detection In Toxicology) , Masson Fontana Stain Kit , Masson Trichome , Masson Trichome Kit , Measuring Scale For Antibiotic Sensitivity , Medicated Adhesive Plaster (Round/Square) , Mesothelial Cell (Hbme-1) , Methadone , Methyl Alcohol Acetone Free , Methyl Green Counter Stain , Methylated Spirit , Metronidazole Disc (5 ?G) , Michelles Medium Solution , Micro Blood Collection Tube Clot Activator , Micro Blood Collection Tube K3 Edta , Micro Blood Collection Tube Sodium Fluoride , Micro Cuvette For 201 , Micro Cuvette For 301 , Microscope Slide Sticker (Size: 15/32”X15/16’) , Microtube Sodium Citrate 3.2% P.T 1Ml , Molecular Diagnostic Kits For Elisa Based Clinical Assays , Moses Ergo Graph Paper , Mpo Anca , Msa , Mucicarmine , Multi Use Cylindrical Tube Adaptor With Needles Of Appropriate Pore Size(For Blood Sampling) , Multi-Enzymecleaner 12% (Protease, Lipases, Amylases) , Multiplex Real Time Pcr Kits For Sars Cov2 , Na Salt Of Chromotropic Acid (2 Units) , Neodisher 1 Ltr Ir Solution , Neodisher Ip Spray 400Ml , Nerve Growth Factor 7S , Neurobasal Media , Neurobasal-A , Neurobasal™ Medium (1X), Liquid, , Normal Goat Serum (Ngs) , Normal Saline , Normal Saline One Liter With Double Outlet (One For Needle And Another For I.V Set) , Nuprep Gel , O1 , Oct Jell (For Frozen Sectiomn) , One Touch Ultra Sugar Test Strips , Opiates , Optimem , Orcein Aldehyde Fuchsin , Osteopontin , Oxidase Paper Disk , P 68 Antibody , Paediatric Vacutainer Pt , Panca Fitc , Paraformaldehyde , Pas – M Stain I , Pas (Periodic Acid Schiff) , Pediatric (Penta) Bags , Pepstatin A=90% , Perforated Tray , Pha-A Solution , Phorbol Myristate Acetate 13 , Phosphate Buffer Saline (Ph-7.0+_.02 At 20°C) , Phosphate Ceramic Solution , Phosphorus (Liquid) , Physio Graph 3Channel Graph Paper , Physio Graph Single Channel Graph Paper , Physioball , Physiograph Ink (Blue Colour) , Phytohemagglutinin, M Form (Pha-M) , Plain Vacutainer(3Ml) With Vaccum , Plain Vacutainer(6Ml) With Vaccum , Plastic Embedding Media & Kits , Poly L-Lysine , Polyclonal , Poly-L-Lysine , Polystyrene Weighing Boats (White (46×46×8)) , Potassium , Potassium Cyanide , Pre Cast Polyacrylamide Mini Gel Electrophoresis Gels , Pre Welded Buccal Tube Bands Right And Left) (31 To 41.5) , Primary Antibodies For Western Blotting And Immunocytochemistry , Procalcitonin By Poct (10 Test) , Procalcitonin Rapid Test By Poct (Box Of Ten Test) , Protease Inhibitor Cocktail Tablets , Protease Inhibitor Cocktail Tablets , Pt Reagent/Tromboplasma , Pyrimidone , Pyruvate Amino Acid , Pyruvate Control , Pyruvate Kit For Autoanalyzer With Calibrator And Control (300 Test) , Pyruvate Kit For Fully Automated Analyser , Pyruvate Kit For Use In Au Series Beckman Coulter , Qc For Igg Antibody To Sars Cov2 , Quality Control For Ada , Quinacrine Dihydro Chloride (4 Packs) , Rapid Card Test For G6pd , Rapid Detection Kit For Antibody Against Rk-39 Antigen , Rapid Ict For Leptospire (Igm) (Ce Certified And Ivd Approved) , Rapid Immunochromatography Test For H1n1 , Rapid Plasma Reagin Kit For Symphilis (Ce & Ivd Approved) , Rapid Test Triage Parasite Panel For Cryptosporidium, Giardia And Entamoeba Histolytica , Rapid Test Urinary Antigen Legionella Pneumophila , Rectified Spirit , Rectified Spirit , Reinsch Tube(For Arsenic Detection) , Restriction Enzymes Molecular Biology Grade , Reticulin Stain Kit , Reticulocyte Counting Fluid , Rheumatoid Factor (Slide) , Rh-Hr (D,C,E,C,E,Ctrl) Column Card/Anti Sera , Rota Adeno Rapid Kit , Rota Virus Antigen Elisa , Rotating Hemostatic Tuohy Borst Single Y Valve , Rotating Hemostatic Valve- Y Type , Rothera’S Powder Mixture , Rotor Adapter , Rotor Adaptor (10*24) , Rpmi Medium , Rpr Rapid Kits , Rubber Bungs , Rubber Gloves Upto Mid Arm , Sda With Gentamicin , Sdp Kit , Seitz Filter , Sera Anti +M , Sera Anti K , Sera Anti Leaa , Sera Anti Leab , Sera Anti P1 , Serum Amyloid A , Serum Ceruloplasmin , Serum Copper , Sheep Serum , Short Length Of Rubber Tubing , Si Rna (Design) , Single Donor Aphresis Kit With Acd Bag , Slee Cellspin Filter Card (200 Stick/ Box) , Sodium Barbitone , Sodium Citrate, Dihydrate, Granular , Sodium Hypochlorite Solution 10% (5 Ltr) , Sodium Polyanethol Sulfonate Disc 10 ?G , Sodium Pyruvate , Solution For Sterilization , Sp100 Antibody For Iif , Starch Powder For Corynebacterium Diphtheriae , Steam Inhaler Machine , Stempro ® Cell Dissociation Reagent , Sterile 12-Well, 96 Well , Sterile Sheep Blood , Sterilizer Chamber Cleaner , Storage Rack For Microscope Slide Boxes (7111×171×228) , Stromatolyser Wh , Sudan Black B Solution , Sulphuric Acid Chromate Solution , Syphilis Rapid Plasma Kit Iv Generation , Syringe Driven Membrane Filter Pore Size 0.22Mm , Syringe Filter (Non - Sterile) , System Calibrator , T20 Conductive Jelly , Taqman Based Primer Probe For Pdm Influenza A (H1n1) * Cdc & Who Approved Primer & Probes. * Concentration Must Be 50 X. * At Least 500 ?L Quantity Must Be Available Per Vial. * Forward Primer, Reverse Primer And Probes Must Be Available In 4 Vials One Each For Inf A, Swine A, Swine H1 And Human Rnase P. * Each Vial Must Contain A Mix Of Forwar Primer, Reverse Primer & Probe At A Concentraion Of 40 ?M (Micro Mole), 40 ?M And 10 ?M Respectively. , Tbnk , 6 Color Antibody Panel , Tbnk , 6 Color Antibody Panel For Flow Cytometry , Tellurite 4% , Tetra Ethylenepentamine , Tetracycline Antibiotoc Disc 10 Mcg , Thc(Tetrahydrocannabinol) Kit , Thymol Tablets , Thymol Tablets , Tibc , Tibc Kit For Fully Automated Analyser , Tlc Plate (Aluminum/ Glass Plate) , Tollens Reagent , Toomy Syringe , Transferrin Calibrator , Transferrin Kit , Transportation Box For Blood Bags (Cold Chain Maintenance) (30 Units Capacity) , Triangular File , Tri-Dot Kit , Triethylammonium Acetate Buffer Solution , Tydal (Widal Ag) , Universal Secondary Antibody , Urea - Stat , Urea (Berthelot) , Urinary Pregnancy Kit , Urine Copper , Urine Dipsticks For Protein And Sugar , Urine Keton Strips (Uristic) , Urine Multistrips , Urine Protein Kit , Vacutainer (5Ml): Green Cap (Heparin) (5Ml) With Vacuum , Vacutainer For Pt /Apttsample(Blue Caps) With Vacuum , Vacutainer For Sugar Samples(5Ml): Grey Cap (5Ml) With Vacuum , Vacutainer(5Ml): Purple Cap (Edta) (5Ml) With Vacuum , Vacutainer(5Ml): Red Cap (5Ml) With Vacuum , Vancomycin E Test Strip , Vectashield Mounting Medium With Antifade (10Ml) , Venereal Disease Research Laboratory (Vdrl) Kit , Vibrio Cholerae Polyvalent O Antisera , Vibrio Rapid Kit , Vitamino Growth Supplement , Von-Kossa Stain , Warthin – Starry Stain Kit , Widal Test Kit For Both Slide And Tube With Test Include To,Th,Ah,Bh And Positive Control , Wintrobe Ers Needle , Xn Cal (Calibrator For Xn 1000 Automated Blood Cell Counter) , Zerostat Spacer Device , Zinc (With Deproteinisation) , ?-1 Acidglycoprotein , Haemotometer , Total Albumine , Blood Glucose (God Pod) , Semen Diluting Fluid , Platelet Diluting Fluid , Absolute Eosin Diluting Fluid , Cytopsin Filter Red , Fitc Anti-Fibronogen Primary Antibody , Fitc Anti-Igg Primary Antibody , Fitc Anti-Kappa Primary Antibody , Fitc Anti - Lambda Primary Antibody , Fitc Anti-Albumin Primary Antibody , Fitc Anti-Ciq Primary Antibody , Fitc Anti-Iga Primary Antibody , Filter Tips With Box 10Ul , Filter Tips With Box 50Ul , Filter Tips With Box 200Ul , Filter Tips With Box 1000Ul , Tweezer Made Of Polycarbonate Metrial , Laboratory Mini Cooler (-20 Digree) Re Chargable Made Of Ploycarbonate , Arsenic Trioxide , Dragendroff Reagent , Flaer , Lipofectamine™ 2000 , Live/Dead Cell Mediated Cytotoxicity Kit , Minimum Non-Essential Amino Acide Solution (100X) , N2 Supplement , Penicillin/Streptomycin 100X , Shellac Powder , Histamine , Acetylcholine , Blood Glucose And Ketone Monitoring System , Blood Glucose And Ketone Monitoring Strip (Note- Compatibal Testing Machine Should Be Provided Free Of Cost Per 100 Pc Each And Every Time Of Purchasing). , Thyroid Peroxidase Ig G (Elisa) , Thyriglobulin (Tg) Ig G (Elisa) , Tsh Receptor Ig G (Elisa) , Gad Ig G (Elisa) , Ia2 Ig G (Elisa) , Anca Profile (Elisa) , C Anca Proteinase 3 (Elisa) , P Anca (Elisa) , Gbm Ig G (Elisa) , Phospholipase-A2 Receptor Elisa Ig G (Elisa) , Soluble Liver Antigen (Sla/Lp) Ig G (Elisa) , Liver-Kidney Microsomes Ig G (Elisa) , Pca Parietal Cells Ig G (Elisa) , Intrinsic Factor Ig G (Elisa) , Acetylcholine Receptor Ig G (Elisa) , Dermatology Profile Elisa Ig G (Elisa) , Desmoglein 1 Ig G (Elisa) , Desmoglein 3 Ig G (Elisa) , Bp230-Cf Ig G (Elisa) , Bp180-Nc16a-4X Ig G (Elisa) , Cylic Citrullinated Peptides Ig G (Elisa) , Histones Ig G (Elisa) , Dsdna-Ncx Ig G (Elisa) , Nucleosomes Ig G (Elisa) , Anti Ena Profile Plus 1 Ig G (Elisa) , Anti Ena Sle Profile 2 Ig G (Elisa) , Anti Ena Profile Plus 2 Ig G (Elisa) , Ana Screen Ig G (Elisa) , Nrnp/Sm Ig G (Elisa) , Sm Ig G (Elisa) , Ss-A (Ro) Ig G (Elisa) , Ss-B (La) Ig G (Elisa) , Scl 70 Ig G (Elisa) , Dfs70 Ig G (Elisa) , Centromeres Ig G (Elisa) , Anti Cardiolipin Ig A (Elisa) , Anti Cardiolipin Ig G (Elisa) , Anti Cardiolipin Ig M (Elisa) , Anti Cardiolipin (Total) (Elisa) , Ama M2 Ig G (Elisa) , Phosphatidylserine Ig A (Elisa) , Phosphatidylserine Ig A Ig G Ig M (Elisa) , B2-Glycoprotein 1 Ig A (Elisa) , B2-Glycoprotein 1 Ig G (Elisa) , B2-Glycoprotein 1 Ig M (Elisa) , B2-Glycoprotein 1 Total (Elisa) , Ribosomal Proteins (Elisa) , Anti Jo-1 Ig G (Elisa) , Rheumatoid Factor Ig A (Elisa) , Rheumatoid Factor Ig G (Elisa) , Rheumatoid Factor Ig M (Elisa) , Tissue Transglutaminase Ig A (Elisa) , Tissue Transglutaminase Ig G (Elisa) , 25-Oh Vitamin D (Elisa) , Beta-Amyloid (1-40) Determination In Csf (Elisa) , Beta-Amyloid (1-42) Determination In Csf (Elisa) , Total Tau Determinatin In Csf (Elisa) , Uromodulin Determination In Serum (Elisa) , Calprotectin Determination In Stool (Elisa) , Interferon-Gamma Determination In Plasma (Elisa) , Saccharomyces Cerevisiae Ig A (Elisa) , Saccharomyces Cerevisiae Ig G (Elisa) , Gliadin Ig A (Elisa) , Gliadin Ig G (Elisa) , Total Ig E (Elisa) , C1q Cic (Elisa) , Aps/Pt Ig M Elisa (Anti-Phosp) , Anti C1q (Elisa) , Hla B27 By Nuclei Acid Amplification Based Assays , Automated Nucleic Acid Extraction System And Materials , Glusose 6 Phosphate Dehydragenase (G6pd) Qualitative Testing Rapid Card Test , Drug Assay For Serum Tecrolimus Estimation , Drug Assay For Serum Methotrexate Estimation , Drug Assay For Serum Cyclosporine Estimation , Cystatin C , Lipoprotein A , Wide Range Crp Linearity Upto 320Mg/Litre , Serum Free Lambda Light Chain , Serum Free Kappa Light Chain , Total Serum Ige , Glycated Serum Protein , Albumin Liquid Reagent , Eqas Program: Clinical Chemistry Program 1. Program Should Be Lyophilized, Human Serum Based 2.Analytes Included Alt, Albumin, Alp, Amylase, Ast, Total Bilirubin, Direct Bilirubin, Indirect Bilirubin, Ionized Calcium, Total Calcium, Chloride, Hdl Cholesterol, Creatinine Kinase, Creatinine, Glucose, Iron, Iron Binding Capacity, Lactate. Dehydrogenase, Lipase, Lithium, Magnesium, Phosphate, Potassium, Total Protein, Sodium, Tsh, Total T4, Total T3, Triglycerides, Urea, Uric Acid, Ldl Cholesterol, Bilirubin (Indirect) & Cortisol , Eqas: Immunoassay Program Program Should Be Lyophilized, Human Serum Based, Comprehensive Menu Of The Most Tested Immunoassay Analytes. Analytes Included: Afp, Estradiol(E2), U E3(Unconjugated Estriol), Ferritin, Folate, Hcg, Tsh, Ft3, Ft4, Total T3, Total T4, Vitamin B12, Cortisol, Dheas, Digoxin, Fsh, Lh, Amh, Insulin, Intact Pth, Progesterone, Prolactin, Testosterone, Ca 19.9, Ca 125, Cea, Tpsa, Free Psa, Ige. , Eqas Hemoglobin Program Program Should Be Lyophilized, Human Whole Blood Based. Analytes Included Hba1c, Hba2, , Eqas Urine Chemistry Program Program Should Be Lyophilized, Human Urine Based. Analytes Included: Magnesium, Total Calcium, Chloride, Total Protein, Microalbumin, Sodium, Creatinine, Urea Etc. , Eqas Cardiac Markers Program Program Should Be Liquid, Human Plasma And Whole Blood Based. Analytes Included: Nt-Pro Bnp, Ckmb, Homocysteine, Hs Crp, Troponin I, Troponin T , Eqas Immunoassay Program For Special Proteins Program Should Be Lyophilized, Human Serum Based. Should Include Analytes Like Beta 2 Macroglobulin, Immunoglobulins Like Igg, Iga, Igm, Ige , Complement3and 4,Creactive Protein, Aso, Rheumatoid Factor , Eqas Abg Program Program Should Be Liquid, Aqueous Sample Based. Should Include Analytes Like P H, P Co2, Po2, Magnesium, Sodium, Potassium, Ionized Calcium, Chloride, Lactate. , Nt-Pro Bnp , Ck-Mb , Troponin T , Neonatal Tsh Screening Pack Size- 96Well Platex6 (Elisa Kits For 8 Different Tests To Be Performed Under Nbs) , Neonatal 17-Oh-P Screening Pack Size-96 Well Platex6 (Elisa Kits For 8 Different Tests To Be Performed Under Nbs) , Neonatal Total Galactose Screening Pack Size-96 Well Platex6 (Elisa Kits For 8 Different Tests To Be Performed Under Nbs) , Neonatal Pku Screening Pack Size-96 Well Platex6 (Elisa Kits For 8 Different Tests To Be Performed Under Nbs) , Neonatal Msud Screening Pack Size-96 Well Platex6 (Elisa Kits For 8 Different Tests To Be Performed Under Nbs) , Neonatal G6pd Deficiency Detection & Screening Pack Size-96 Well Platex5 (Elisa Kits For 8 Different Tests To Be Performed Under Nbs) , Neonatal Biotinidase Screening Pack Size-96 Well Platex5 (Elisa Kits For 8 Different Tests To Be Performed Under Nbs) , Neonatal Irt Screening Pack Size-96 Well Platex6 (Elisa Kits For 8 Different Tests To Be Performed Under Nbs) , Dried Blood Spot Sample Collection Cards 100Pcs/Packet , Hu Cd3 Horizon V450 Ucht1 , Cd45 V510 , Anti-Mpo Fitc 5B8 50 Tests , Cd79a Pe Hm47 50 Tests , Cd34 Percp-Cy5.5 8G12 50 Tests , Cd19 Pe-Cy7 Sj25c1 100 Tests , Cd7 Apc (M-T701) , Cd3 Apc-H7 Sk7 100 Tests , Cd20 V450 L27 100 Tests , Hu Cd58 Fitc 1C3 100Tst , Hu Cd66c Pe B6.2/Cd66c 100Tst , Cd10 Apc Hi10a 100 Tests , Cd38 Apc-H7 (Hb7) , Cd4 V450 (Sk3) , Hu Cd1a Fitc Hi149 100Tst , Hu Cd99 Pe Tu12 100Tst , Cd5 Percp-Cy5.5 L17f12 50 Tests , Cd2 Pe-Cy7 L303.1 100 Tests , Anti-Tdt Apc E17-1519 100Tests , Cd8 Apc-H7 Sk1 100 Tests , Anti-Hla-Dr V450 100 Tests , Hu Cd64 Fitc 10.1 100Test , Cd13 Pe L138 100 Tests , Cd117 Pe-Cy7 104D2 100Tests , Cd33 Apc P67.6 100 Tests , Cd14 Apc-H7 Mphip9 100Tests , Cd15 Fitc Mma 100 Tests , Cd56 Pe My31 100 Tests , Hu Cd41a Pe-Cy7 Hip8 50Tst , Cd123 Apc (9F5) , Cd71 Apc-H7 M-A712 , Cd8 Fitc Sk1 100 Tests , Anti-Lambda Fitc 1-155-2 50Tst , Anti-Kappa Pe Tb28-2 50Tests , Tcr Gamma/Delta-1 Pe-Cy7 (11F2) , Cd3 Apc Sk7 100 Tests , Lysing Buffer 10X Concentrate 100Ml , Cd81 Apc-H7 (Js-81) , Hu Neuropilin-1 Pe U21-1283 100Tst , Hu Cd73 Horizon V450 Ad2 50Tst , Hu Cd123 Fitc 7G3 100Tst , Hu Cd86 Pb 100Tst , Hu Cd3 Bb515 Sk7 100Tst , Cd5 Pe L17f12 100 Tests Ruo/Gmp , Cd4 Percp-Cy5.5 Sk3 , Cd56 Pe-Cy7 Ncam16.2 100 Tests , Bd Intrasure Kit Ruo , Bd Facs Lysing Solution 10X 100Ml Ivd , Cd23 Fitc Ebvcs-5 Ruo , Cd10 Pe (Mem-78) Ruo , Cd79b Percp-Cy5.5 Sn8 , Cd200 Apc (Mrc Ox-104) , Cd43 Apc-H7 (1G10) , Cd25 Fitc 2A3 100 Tests , Cd103 Pe Ber-Act8 50 Tests , Cd11c Percp-Cy5.5 (B-Ly6) , Cd26 Pe L272 50 Tests , Cd8 Percp-Cy5.5 Sk1 50 Tests , Cd45 V450 2D1 100 Tests , Cd138 V500-C , Cd38 Fitc Hb7 50 Tests , B2-Microglobulin Percp-Cy5.5 , Hu Kpa Apc G20-193 50Tst , Anti-Lambda Apc-H7 , Cd28 Pe L293 100 Tests , Cd27 Percp-Cy5.5 (L128) , Cd117 Apc 104D2 100 Tests , Cd 157 Pe , Cd 235A Fitc , Stem Cell Enumeration Stem Cell Control Cd34+ Whole Blood Process Control Bd Facs™ 7-Color Setup Beads Rainbow Flrs Prtcl Bright 3.0- 3.4Um 5Ml , Cd 62Pe/ Fitc , Cd 63 Pe Cy 5.5 , Cd71 Fitc , Cd42 Pe , Cyclin D1 Fitc , Cd 43 Apc H7 , Cd 123 Bv 605 , Cd 304 Apc R 700 , Cd 103 Fitc , Cd 9 Pb , Ng 2 Pe , Cd 21 Pb , Tcl 1 Apc , Cd 303 Pe , Cd 16 Pe , Cd 27 Ecd , Cd 4 Per Cp Cy 5.5 Rpa T4 , Tcrgd Immu-510 Pc 7 , Cd14 Rmo52 Apc 700 , Cd 45 2D1 Apc 750 , Hladr Immu-357 Pb , Cd45ra H100 Bv 510 , Igd Ia6-2 Fitc , Igm Mhm-88 Per Cp Cy 5.5 , Cd19j3-119 Pc 7 , Cd 56 Apc R 700 , Cd 33 Bv 605 , Cd 117 Apc R 700 , Cd 7 Bv 605 , Cd 11B Apc H7 , Cd 13 Apc R 700 , Cd 20 Bv 605 , Cd 34 Pe , Cd 38 Per Cp , Anti Kappa Apc , Cd 45 R700 , Cd 64 , Cd 59 , Cd5 Bv 421 , Cd 200 Pe , Fmc 7 Bv 421 , Cd 49D , Cd148 Apc , Saa(Serum Amyloid A) , Ca19-9 , Caspases 3/8 , Carbonic Anhydrase Ix , Factor Ix , Pten , Claudin-1 , Collagen –Iv , Glut-1 , P120 , Villin , H.Pylori , Hsv I/Ii , Hbcag , Mitf , Tyrosinge , Cd63 , Phh3 , Ck(B4ße12 , Psap , C4d , Gastrin , Somatostatin , Galestin- 3 , P21 , P27 , Annexin A1 , Ck5+Ck14 (Baseloid Cocktail) , Adenovirus , Check-Stix (Control For Semiautomated Urine Analyzer) , Adipophilin , Bcor , Bap1 , Bsep , Clusterin , Ccnb3 , Desmoglein 1 , Desmoglein 3 , Dux4 , Erg , Galectin-3 , Hla-Dr , H3f3a (Histone 3.3) , Phosphorylated Histone H3 (Phh3) , Nut , Rb , Tia , Zap70 , Yap , Pdl1(22C3) , Phlda1 , Braf V600e , Warthin-Starry , Smad4 / Dpc4 , Uroplakinii , Fumarate Hydratase , Sdhb , Muc2 , Muc3 , Muc4 , Muc6 , Sox9 , Anti Pla2r , Anti Nell-1 , Anti-Semaphorin 3B , Anti Thsd7a , Anti Ext-1 , Anti Dnajb9 , Anti Lect 2 , Anti Lrp2 , Fitc Igg1 Antibody , Fitc Igg2 Antibody , Fitc Igg3 Antibody , Fitc Igg4 Antibody , Eosin-5-Maleimide (Ema) Dye , Eber Probe For Ish , Proteinase K Enzyme , Glycerol Mounting Agent , Oct 4 , Gh , Insn1 , Smarca4 / Brg1 , Dystrohin , Dysferlin , Sacroglycan , Emerin , Laminin Alpha 2 , Betadystroglycan , Majos Histocompatibility Complex 1 , Ish Blue Detection Kit , Ish Protease 2 , Rpmi 1640 Medium , Penstrep Antibiotic Solution , Fetal Bovine Serum , Phytohemagglutinin , Colchicine , Carnoys Fixative , Sorensens Buffer (Ph-7) , Trypsin- Edta (0.25%) Solution , Mitomycin C , Ssc Solution (20X) , Formamide , Np-40 Solution , Probechek Control Slides For Pathvysion® Her-2 Dna Probe Kit Cut-Off Control , Probechek Control Slides For Pathvysion Her-2 Dna Probe Kit Normal Control , Vysis Cll Fish Probe Kit , Probechek Prenatal Control Slides For Positive Control , Aneuvysion Dna Probe Kit , 50 Assay , Probechek Prenatal Control Slides For Amniocyte; Male Amniocyte Control , Pathvysion Her-2 Dna Probe Kit Ii, 100 Assays , Cep 8 Spectrumorange Dna Probe Kit, 20 Assay , Cep X Spectrumorange / Cep Y Spectrumgreen Dna Probe Kit, 20 Assay , Cep 8 Spectrumorange Dna Probe Kit With Control Slides, 20 Assay , Cep X Spectrumorange / Cep Y Spectrumgreen Dna Probe Kit With Control Slides, 20 Assay , Vysis Alk Break Apart Fish Probe Kit , Vysis Egr1 Fish Probe Kit - Sc (Specimen Characterization) , Vysis D7s486/Cep7 Fish Probe Kit , Vysis Lsi 1P36/Lsi 1Q25 And Lsi 19Q13/19P13 Dual Color Probes , Vysis Lsi Cbfb Dual Color Break Apart Rearrangement Probe , Vysis Lsi Pml/Rara Dual Color Dual Fusion Probes , Vysis Lsi Igh/Fgfr3 Dual Color Dual Fusion Probes , Vysis Lsi Tp53 Spectrumorange/Cep 17 Spectrumgreen Probe , Vysis Lsi Igh/Maf Dual Color Dual Fusion Probes , Vysis Lsi Bcr/Abl Dual Color Dual Fusion Probes , Vysis Bcr/Abl1/Ass1 Tri-Color Df Fish Probe , Vysis Lsi Bcl2 Break Apart Fish Probe Kit , Vysis Lsi Igh Dual Color Break Apart Rearrangement Probe , Vysis Lsi Myc Dual Color Break Apart Rearrangement Probe , Vysis Lsi Bcl6 Dual Color, Break Apart Rearrangement Probe , Vysis Lsi Igh/Ccnd1 Dual Color Dual Fusion Probes , Vysis Lsi Etv6 (Tel)/Runx1 (Aml1) Es Dual Color Single Fusion Probe , Vysis Egfr / Cep 7 Fish Probe Kit , Vysis Lsi D20s108 Spectrumorange Probe , Paraffin Pretreatment Kit I , Fish Pretreatment Kit , Vp 2000 Reagents – Pretreatment Reagent (500 Ml) , Vp 2000 Reagents – Protease Buffer (500 Ml) , Vp 2000 Reagents – Protease I (250 Mg X 2) , Antifade Ii Solution , Antifade Solution , Dapi I Counterstain (1000 Ng/Ml) , Dapi Iii Counterstain (42 Ng/Ml) , Dapi Ii Counterstain (125 Ng/Ml) , Lsi®/Wcp® Hybridization Buffer , Lsi/Wcp Hybridization Buffer , Vp 2000 Reagents – Protease Ii (750 Mg) , Cep® Hybridization Buffer , Vysis Intellifish Universal Ffpe Tissue Pretreatment And Wash Reagents Vysis Intellifish Pretreatment Ssc Solution – 2 X 250Ml Bottles , Vysis Intellifish Protease Buffer - 2 X 250Ml Bottles , Vysis Intellifish Post-Hybridization Wash Buffer - 3 X 250Ml Bottles , Vysis Intellifish Universal Ffpe Tissue Pretreatment Protease , Vysis Intellifish Hybridization Buffer , 6Q22 Ros1 Break Apart Fish Probe Ruo Kit , Nucleodx Blood Dna Extraction Mini Kit , Nucleodx Pcr Purification & Gel Extraction Mini Ki , Nucleodx Magnetic Bead Nucleic Acid Extraction Ki , Bcr-Abl-1 Quantitative Rt-Pcr Kit - Major , Bcr-Abl Qualitative Rt-Pcr Kit - Major, Minor & Micro , Kras Mutation Detection Kit , Jak2 V617f Mutation Detection Kit , Pml-Rara Qualitative Rt-Pcr Kit , Braf Qualitative Rt-Pcr Kit , Nadh-Tr (Nicotineamide Adenine Dehydrogenase) , Sdh ( Succinate Dehydrogenase) , Cox ( Cytochrome Oxidase) , Atpase , Modified Gomori Trichrome , Verhoff Van Gieson , Oil Red O , N-Ethylmaleimide , Red Counter Stain , Stainless Steel Bone Marrow Needles 11G (Autoclavable) , Stainless Steel Bone Marrow Needles 13G (Autoclavable) , Stainless Steel Bone Marrow Needles 16G (Autoclavable) , Stainless Steel Bone Marrow Needles 18G (Autoclabable) , Glass Marking Diamond Pencil , Glass Slide Sticker , Dihydrahodamine 123 , Phorbol Myristate Acetate , Ada Kit For Fully Automated Clinical Chemistry Analyser With Calibrator And Control , Antibody To Anca - Mpo , Antibody To Anca - Pr 3 , Antibody To Gliadin (Iga - Gliadin , Antibody To Tissue Transglutaminase (Iga - Ttg) , Azelaic 20% Resorcinol 10% + Phytic 6% + Tranexmic 3% 50Ml , Cd20 Apc-H7 L27 100 Tests Ruo/Gmp , Cd33 Pe P67.6 Ruo/Gmp , Cd36 Fitc Clb-Ivc7 Ruo , Cd4 Pe-Cy7 Sk3 100 Tests Ruo/Gmp , Cd45 Apc-H7 2D1 100 Tests Ruo/Gmp , Cd8 Fitc Sk 100 Tests Ruo/Gmp , Citrosteril (For Heat Disinfection) (Citric Acid - 1 Hydate, Lactic Acid, Malic Acid (21%) , Conductive Neurodiagnostic Electrode Paste , Crp Kit For Automated Analyser , Dialysis Fluid Part A (Hemodialysis Solution Concentration Part A 36.83X Diluted 1:34 Contains Sodium 82.50 Mmol/L, Potassium-2.00Mmol/L, Calcium-1.75Mmol/L, Magnesium-0.75 Mmol/L, Acetic Acid-4.00 Mmol/L, Dextrose-5.54 Mmol/L, Chloride-89.63 Mmol/L) , Dialysis Fluid Part A Glucose Free , Dialysis Fluid Part A Potassium Free , Dialysis Fluid Part A With Dextrose , Dialysis Fluid Part B (Bibag) ( Sodium Bicarbonate For Haemodialysis ) , Direct Bilirubin Kit For Automated Analyser , Glycolic 35% + Kojic 10% Puruvic 2% Lactic 10% , Glycolic Acid 20% , Glycolic Acid 30% , Glycolic Acid 50% + Lactic Acid 10% + Salicylic Acid 4% , Glycolic Acid 50% , Hbsag Rapid Test Kit , Hcv Rapid Kit , Hu Cd14 Pe-Cy7 Mphip9 , Hu Cd15 Percp-Cy5.5 Hi98 , Hu Cd24 Alexa 647 Ml5 , Hu Cd38 Percp-Cy5.5 Hit2 100Ug , Imidazole Ar, Acs , Inorganic Phosphorus (100 Reactions) , Lactic 15% + Kojic 5% + Citric 5% + Arginine 5% , Lactic 45% + Citric 5% + Pyruvic 5% + Arginine 5% , Lactic Acid 17% + Salicylic Acid 17% + Citric Acid 8% , Lactic Acid 17% + Salicylic Acid 17% + Resorcinol 14% , Mandelic 20% , Mandelic 30% , Mandelic 40% , Mellibose , Microtube Sodium Citrate 3.2% Pt , Pyruvic Acid 25% + Lactic Acid 25% , Rapid Dipstick Test For Detection Of Igfbp - 1 , Rapid Dipstick Test For Detection Of Pre Term Factor Ph - Igfbp - 1 , Rapid Kit For Rk - 39 , Skin Prep Gel , Total Calcium Kit (100 Reactions) , Total Cholesterol Kit (100 Reactions) , Cefazolin Antibiotic Disk (In Cartridge Packing) , Cefazolin Antibiotic Disk (In Vials) , Penicillin Antibiotic Disk (In Cartridge Packing) , Penicillin Antibiotic Disk (In Vials) , Tigecycline Antibiotic Disk (In Cartridge Packing) , Tigecycline Antibiotic Disk (In Vials) , Minocycline Antibiotic Disk (In Cartridge Packing) , Minocycline Antibiotic Disk(In Vials) , Doxycycline Antibiotic Disk (In Cartridge Packing) , Doxycycline Antibiotic Disk(In Vials) , Oxacillin Antibiotic Disk (In Cartridge Packing) , Oxacillin Antibiotic Disk(In Vials) , Ceftolozane Tazobactam Antibiotic Disk (In Cartridge Packing) , Ceftolozane Tazobactam Antibiotic Disk (In Vials) , Ceftazidime Avibactam Antiobiotic Disk (In Cartridge Packing) , Ceftazidime Avibactam Antiobiotic Disk (In Vials) , Imipenem Relebactam Antibiotic Disk(In Vials) , Imipenem Relebactam Antibiotic Disk (In Cartridge Packing) , Meropenem Vaborbactam Antibiotic Disk(In Vials) , Meropenem Vaborbactam Antibiotic Disk (In Cartridge Packing) , Cefiderocol Antibiotic Disk (In Cartridge Packing) , Cefiderocol Antibiotic Disk(In Vials) , Doripenem Antibiotic Disk (In Cartridge Packing) , Doripenem Antibiotic Disk(In Vials) , Ertapenem Antiobiotic Disk (In Cartridge Packing) , Ertapenem Antiobiotic Disk(In Vials) , Tobramycin Antibiotic Disk(In Vials) , Tobramycin Antibiotic Disk (In Cartridge Packing) , Plazomycin Antibiotic Disk(In Vials) , Plazomycin Antibiotic Disk (In Cartridge Packing) , Netilmicin Antibiotic Disk (In Vials) , Netilmicin Antibiotic Disk (In Cartridge Packing) , Pefloxacin Antibiotic Disk(In Vials) , Pefloxacin Antibiotic Disk (In Cartridge Packing) , Fosfomycin Antibiotic Disk (Containing 50Mcg Glucose 6 Phosphate)(In Vials) , Fosfomycin Antibiotic Disk (Containing 50Mcg Glucose 6 Phosphate) (In Cartridge Packing) , Ervacycline Antibiotic Disk (In Vials) , Ervacycline Antibiotic Disk (In Cartridge Packing) , Levonadifloxacin Antibiotic Disk (In Vials) , Levonadifloxacin Antibiotic Disk (In Cartridge Packing) , Ceftaroline Antibiotic Disk(In Vials) , Ceftaroline Antibiotic Disk (In Cartridge Packing) , Moxifloxacin Antibiotic Disk(In Vials) , Moxifloxacin Antibiotic Disk (In Cartridge Packing) , Rifampicin Antibiotic Disk(In Vials) , Rifampicin Antibiotic Disk (In Cartridge Packing) , Polymyxin B Antibiotic Disk(In Vials) , Polymyxin B Antibiotic Disk (In Cartridge Packing) , Polymyxin B Antibiotic Disk(In Vials) , Polymyxin B Antibiotic Disk (In Cartridge Packing) , Ceftazidime Avibactam E Strip , Amikacin Antibiotic Disk (In Cartridge Packing) , Ampicillin Antibiotic Disk (In Cartridge Packing) , Amoxicillin- Clavulanate Antibiotic Disk (In Cartridge Packing) , Ampicillin- Sulbactam Antibiotic Disk (In Cartridge Packing) , Aztreonam Antibiotic Disk (In Cartridge Packing) , Azithromycin Antibiotic Disk (In Cartridge Packing) , Cefepime Antibiotic Disk (In Cartridge Packing) , Cefotaxime Antibiotic Disk (In Cartridge Packing) , Cefoxitin Antibiotic Disk (In Cartridge Packing) , Cefixime Antibiotic Disk (In Cartridge Packing) , Ceftazidime Antibiotic Disk (In Cartridge Packing) , Ceftriaxone Antibiotic Disk (In Cartridge Packing) , Cefuroxime Antibiotic Disk (In Cartridge Packing) , Ciprofloxacin Antibiotic Disk (In Cartridge Packing) , Clindamycin Antibiotic Disk (In Cartridge Packing) , Cotrimoxazole Antibiotic Disk (In Cartridge Packing) , Erythromycin Antibiotic Disk (In Cartridge Packing) , Gentamicin Antibiotic Disk (In Cartridge Packing) , High Level Gentamicin Antibiotic Disk (In Cartridge Packing) , Imipenem Antibiotic Disk (In Cartridge Packing) , Levofloxacin Antibiotic Disk (In Cartridge Packing) , Linezolid Antibiotic Disk (In Cartridge Packing) , Meropenem Antibiotic Disk (In Cartridge Packing) , Nitrofurantoin Antibiotic Disk (In Cartridge Packing) , Norfloxacin Antibiotic Disk (In Cartridge Packing) , Piperacillin- Tazobactam Antibiotic Disk (In Cartridge Packing) , Teicoplanin Antibiotic Disk (In Cartridge Packing) , Tetracycline Antibiotic Disk (In Cartridge Packing) , Vancomycin Antibiotic Disk (In Cartridge Packing) , Novobiocin Disk (In Vial) , Polymyxin B Antibiotic Powder(Analytical Grade) , Iron Depleted Cation Adjusted Mueller Hinton Broth , Cation Adjusted Mueller Hinton Broth , Cefiderocol Microdilution Panel In Iron Depleted Cation Adjusted Mueller Hinton Broth , Chelating Resin Powder/Granules (Analytical Grade) , Fosfomycin Powder (Analytical Grade) , Oxacillin Powder (Analytical Grade) , Vancomycin Powder (Analytical Grade) , Colistin Powder (Analytical Grade) , Cefiderocol Powder (Analytical Grade) , Plazomycin Powder (Analytical Grade) , Ceftazidime Avibactam Powder (Analytical Grade) , Aztreonam Powder (Analytical Grade) , Ervacycline Powder (Analytical Grade) , Brain Heart Infusion (Bhi) Agar , Glucose 6 Phospate Powder (Analytical Grade) , Staphylococcus Aureus Latex Agglutination Test , Arabinose Powder (Analytical Grade) , Latex Agglutination Test Kit For Meningitis Panel Organisms: Streptococcus Pneumoniae Haemophilus Influenzae Type B, Escherichia Coli K1, Listeria Monocytogenes, Group B Streptococcus, And Neisseria Meningitidis , Pneumococcal Antigen Detection Rapid Test Kit (For Csf & Serum) , Corynebacterium Diphtheriae Toxin Assay - Rapid Test Kit , Anti Diptheria Antitoxin/Serum For Elek Gel Test , Mycobacterium Tuberculosis Urine Lipoarabinomannan (Lam) Lateral Flow Assay Test , Mycobacterium Tuberculosis Igra Test Kit Using Mixture Of Synthetic Peptides Of Esat-6 And Cfp-10 Antigens , Corynebacterium Diphtheriae Toxin Assay - Elisa Test Kit , Salmonella Poly-O Antisera , Salmonella Poly-H Antisera , Salmonella O2- Antisera , Salmonella O4- Antisera , Salmonella O9- Antisera , Salmonella Hd- Antisera , Salmonella Vi- Antisera , Shigella Poly-O Antisera , Lysine Iron Agar Medium , Moller Decarboxylase Broth Base , Lysine Powder (Analytical Grade) , Ornithine Powder (Analytical Grade) , Arginine Powder (Analytical Grade) , Moller Decarboxylase Broth With Lysine , Moller Decarboxylase Broth With Ornithine , Moller Decarboxylase Broth With Arginine , Moller Decarboxylase Broth Kit , Alpha Naphthol Powder , Alpha Naphthalamine Powder , Sulfanilic Acid Powder , Nitrate Broth , Oxidative Fermentative (Of) Medium With Dextrose , Bile Salt (Deoxycholate) Powder(Analytical Grade) , Bromothymol Blue Indicator Solution , Bromocresol Purple Indicator Solution , Lens Cleaning Solution , Pheny Alanine Deaminase Agar , Zinc Sulfate Powder (Analytical Grade) , Hippurate Broth , Streptococcal Lancefield Grouping Latex Agglutination Complete Kit , Caspofungin E Strip , Micafungin E Strip , Anidulafungin E Strip , Amphotericin B E Strip , Fluconazole E Strip , Voriconazole E Strip , Posaconazole E Strip , Itracomazole E Strip , Ketoconazole E Strip , Flucytosine E Strip , Terbinafine E Strip , Caspofungin Powder (Analytical Grade) , Micafungin Powder (Analytical Grade) , Anidulafungin Powder (Analytical Grade) , Amphotericin B Powder (Analytical Grade) , Fluconazole Powder (Analytical Grade) , Voriconazole Powder (Analytical Grade) , Posaconazole Powder (Analytical Grade) , Itracomazole Powder (Analytical Grade) , Ketoconazole Powder (Analytical Grade) , Flucytosine Powder (Analytical Grade) , Terbinafine Powder (Analytical Grade) , Caspofungin Disk (In Cartridge Packing) , Micafungin Disk (In Cartridge Packing) , Anidulafungin Disk (In Cartridge Packing) , Amphotericin B Disk (In Cartridge Packing) , Amphotericin B Disk (In Cartridge Packing) , Fluconazole Disk (In Cartridge Packing) , Voriconazole Disk (In Cartridge Packing) , Posaconazole Disk (In Cartridge Packing) , Itraconazole Disk (In Cartridge Packing) , Flucytosine Disk (In Cartridge Packing) , Terbinafine Disk (In Cartridge Packing) , Rpmi 1640 Medium Powder (Analytical Grade) , Rpmi 1640 Medium Liquid , Pneumocystis Immunofluorescence Assay Kit , Histoplasma Antigen Detection Test Kit , Aspergillus Igm Detection Rapid Kit , Aspergillus Igg Detection Rapid Kit , Cryptococcus Latex Agglutination Test Kit , Cryptococcus Lateral Flow Assay Immuno Chromatographic Test Kit , 1,3 Beta D Glucan Rapid Test , Galactomannan Test- Elisa Format Kit, Compatible For Serum Bal Etc , Galactomannan Test - Lateral Flow Assay Immunochromatographic Test Kit, Compatible For Serum Bal Etc , Calco Fluor White Stain , Chloramphenicol Antibiotic Powder (Analytical Grade) , Gentamicin Antibiotic Powder (Analytical Grade) , Cycloheximide Powder (Analytical Grade) , Sabouraud Dextrose Agar (Sda) With Chloramphenicol , Sabouraud Dextrose Agar (Sda) With Chloramphenicol And Gentamicin , Sabhi Agar , Dermatophyte Test Medium , Dermatophyte Identification Medium , Inhibitory Mould Agar (Ima) With Chloramphenicol , Cornmeal Agar , Cornmeal-Tween 80 Agar , Caffeic Acid Disk , Sabouraud Dextrose Broth , Canavanine Glycine Bromothymol Blue (Cgb) Agar , Creatinine Dextrose Bromothymol Blue Thymine (Cdbt) Agar , Modified Dixon Agar , Gomori Methenamine Silver Stain Kit , Chromic Acid (Chromium Trioxide) , Silver Nitrate , Methenamine (Hexamethylenetetramine) , Borax (Sodium Borate) , Sodium Metabisulfite , Sodium Thiosulfate , Light Green Sf-Yellowish , Glacial Acetic Acid , Gold Chloride , Birdseed Agar (Niger Seed Agar/Staib Agar) , Yeast Nitrogen Base , Yeast Carbon Base , Potassium Nitrate (Kno3) , Agar Agar , Yeast Extract Powder (Analytical Grade) , Sterile Blank Filter Paper Disk (6Mm Diameter) , Glucose Powder (Analytical Grade) , Maltose Powder (Analytical Grade) , Sucrose Powder (Analytical Grade) , Lactose Powder (Analytical Grade) , Galactose Powder (Analytical Grade) , Trehalose Powder (Analytical Grade) , Melibiose Powder (Analytical Grade) , Cellobiose Powder (Analytical Grade) , Inositol Powder (Analytical Grade) , Xylose Powder (Analytical Grade) , Raffinose Powder (Analytical Grade) , Dulcitol Powder (Analytical Grade) , Candida Cabohydrate Assimilation Disk Combination Pack , Glucose Candida Assimilation Disk , Maltose Candida Assimilation Disk , Sucrose Candida Assimilation Disk , Lactose Candida Assimilation Disk , Galactose Candida Assimilation Disk , Trehalose Candida Assimilation Disk , Melibiose Candida Assimilation Disk , Cellobiose Candida Assimilation Disk , Inositol Candida Assimilation Disk , Xylose Candida Assimilation Disk , Raffinose Candida Assimilation Disk , Dulcitol Candida Assimilation Disk , Czapek Dox Agar , Chromotrope 2R Stain , Trichome Stain Kit , Lugols Iodine , Giemsa Stain Kit , Leishman Stain Kit , Geimsa Stain Powder (Analytical Grade) , Romanowsky Geimsa Stain Kit , Leishman Stain Powder (Analytical Grade) , Malaria Parasite Staining Kit , Albert Metachromatic Granule Staining Kit , Lateral Flow Assay Immunochromatographic Combined Test For Giardia, Cryptosporidium & Entamoeba , Lateral Flow Assay Immunochromatographic Test For Circulating Filarial Antigen (Cfa) , Fecal Parasite Concentration Kit (50 Tests) , Quantitative Buffy Coat Capillary Tube With One End Coated With Acridine Orange And One End Coated With Edta , Quantitative Buffy Coat Capillary Tube For Detection Of Malaria , Malaria Detection Kit (Real Time Probe Based Pcr) , Plasmodium Species Detection Kit (Multiplex Real Time Probe Based Pcr) , Macconkey Broth Double Strength With Bromocresol Purple , Bacterial Membrane Filter Papers 0.22Microns , Bacterial Membrane Filter Papers 0.45Microns , Bacterial Endotoxin Assay Test Kit (Qualitative, Gel Clot) , Bacterial Endotoxin Assay Test Kit (Qualitative, Colorimetry) , Bacterial Endotoxin Assay Test Kit (Quantitative) , Mpt 64 Test Kit , Middlebrook 7H9 Broth Tubes Compatible With Bd Mgit System , Auramine Phenol And Rhodamine Stain , Tris(Hydroxymethyl)Aminomethane Hydrochloride (Tris Hcl) Molecular Weight: 157.60 , Tris(Hydroxymethyl)Aminomethane (Tris) Base Molecular Weight: 121.14 , Ethylenediaminetetraacetic Acid (Edta) Tetrasodium Salt Dihydrate , Ethylenediaminetetraacetic Acid (Edta) Disodium Salt Dihydrate , Tris Borate-Edta Buffer Concentrate (Minimum 10X) , Tris Acetate – Edta Buffer Concentrate (Minimum 10X) , Proteinase K Lyophilized Powder, Bioultra, =30 Units/Mg Protein, For Molecular Biology(Analytical Grade) , Lyticase Lyophilized Powder, =2,000 Units/Mg Protein, For Molecular Biology, A Pack Of 25000 Units (Analytical Grade) , Saponin, For Molecular Biology, Used As Non-Ionic Surfactant , Lysozyme Powder (Molecular Grade) , Lysozyme Solution (Molecular Grade) , Sodium Dodecyl Sulfate (Sds) Powder, For Molecular Biology (Analytical Grade) , Cetyltrimethylammonium Bromide (Ctab) Powder, For Molecular Biology (Analytical Grade) , Phenol/Chloroform/Isoamyl Alcohol, 25:24:1 (V/V), Molecular Biology Grade , Chloroform/Isoamyl Alcohol, 25:24:1 (V/V), Molecular Biology Grade , Phenol , Chloroform , Isoamyl Alcohol , Agarose Powder, Molecular Grade , Acridine Orange Hydrochloride Solution , Acridine Orange Hydrochloride Anhydrous Powder (Analytical Grade) , Ethidium Bromide Powder , Sybr Green Powder, Molecular Grade , Dntp Set, 100 Mm, With Individual Dntps For Routine Pcr; 0.25 Ml Each , Deoxynucleotide Set, 10 Mm, With Individual Dntps For Routine Pcr; 0.5 Ml Each , Taq Dna Polymerase 5 U/?L For Pcr With Inert Dye; With 10X Taq Buffer Containing Mgcl2, , Taq Dna Polymerase 5 U/?L For Pcr With Inert Dye; With 10X Taq Buffer Without Mgcl2, With , 1 Kb Dna Ladder/Gel Marker For Gel Electrophoresis , 6X Dna Loading Buffer Dye , Custom Dna Primers/Oligos Of 20 Bases (Range Of 18 To 25 Bases), In Lyophilised Form, With Certificate Of Analysis Including Yield, Tm (Melting Temperature), Mw, And ?G/Od , Custom Qpcr/Real Time Pcr Hybridization Probes With Customised Dyes E.G. 6-Fam, Tamra, Joe, Txrd (Sulforhodamine 101-X), Wellred (D2, D3 & D4), Hex, Tet, Cyanine Dyes , Custom Next-Gen Sequencing Oligos, Universal And Index (Barcode) Adapter Oligos For Major Sequencing Platforms , Predesigned Primer Pairs Of 20 Bases (Range Of 18 To 25 Bases) , Sorbitol Mcconkey Agar , Brilliant Green Bile Broth , Selenite F Broth , Gram Negative Broth , Deoxycholate Citrate Agar , Salmonella Shigella Agar , Columbia Blood Agar Base With Gonococcal Growth Supplement , Gc Agar Base , Gc Agar Base With Vcn/Vcnt Supplement And Gonococcal Growth Supplement , Penicillin Powder (Analytical Grade) , Plastic Inoculation Loop, Disposable , Chlamydia Enzyme Immuno Assay Test Kit , Chlamydia Direct Fluorescent Assay Test Kit , Trichomonas Culture Medium Agar With Selective Supplement , Trichomonas Culture Medium Broth (Modified Diamonds) , Sheep Blood , Glass Tube, 10Ml, Screw Capped With Rubber Gasket, Autoclavable , Glass Tube, 15Ml, Screw Capped With Rubber Gasket, Autoclavable , Micro Titre Plate 96Wells Flat Bottom Autoclavable , Micro Titre Plate 96Wells Round Bottom Autoclavable , Phenyl Ethyl Agar , Neomycin Powder (Analytical Grade) , Anaerobic Blood Agar Base , Brucella Blood Agar Base , Brucella Blood Agar Base With Haemin And Vitamin K Upplement , Anaerobic Egg Yolk Agar Base , Thioglycolate Powder (Analytical Grade) , Robertson Cooked Meat Medium With Glucose, Haemin And Vitamin K , Loeffler Serum Slope (Lss) Media Slant , Haemin Powder (Analytical Grade) , Vitamin K Powder (Analytical Grade) , Buffered Charcoal Yeast Extract Agar , Buffered Charcoal Yeast Extract Agar With Legionella Supplement , Regan Lowe Medium With Bordetella Supplement , Campylobacter Agar Base With Campylobacter Supplement , Cycloserine Cefoxitin Fructose Agar , Todd Hewitt Broth , Luria Bertani Broth , Aztreonam Avibactam Powder (Analytical Grade) , Penicillin E- Strip , Ceftriaxone E-Strip , Antimicrobial Disk Dispenser, 6 Positions , Digital Electronic Vernier Caliper, With Large Lcd Screen, Auto-Off Feature, Inch And Millimeter Conversion , Micro Pipette 0.1-1?L , Micro Pipette 0.2 - 2?L (P2) , Micro Pipette 1-10 ?L (P10) , Micro Pipette 2-20 ?L (P20) , Scrub Typhus Igm Elisa Kit(Ce & Ivd Approved) , Scrub Typhus Igg Elisa Kit(Ce & Ivd Approved) , Leptospira Igm Elisa Kit(Ce & Ivd Approved) , Leptospira Igg Elisa Kit(Ce & Ivd Approved) , Rose Bengal Latex Agglutination Test Kit , Brucella Igm Elisa Kit(Ce & Ivd Approved) , Brucella Igg Elisa Kit(Ce & Ivd Approved) , Bordetella Igm Elisa Kit (Ce & Ivd Approved) , Bordetella Igg Elisa Kit(Ce & Ivd Approved) , Haemophilus Factor X Disk , Haemophilus Factor V Disk , Haemophilus Factor Xv Disk , Campylobacter Antigen Detection Rapid Test Kit , Helicobacter Pylori Antigen Detection Rapid Test Kit , Weil Felix Test Kit , High Sensitive C Reactive Protein (Hs-Crp) Latex Agglutination Test , Corynebacterium Diphtheriae Atcc , Haemophilus Influenzae Atcc 10211 , Bacteroides Fragilis Atcc 25285 , Clostridioides Difficile Atcc 700057 , Neisseria Gonorrhoeae Atcc 49226 , Staphylococcus Aureus Atcc Baa 1708 , Staphylococcus Aureus Atcc Baa 977 , Escherichia Coli Atcc Baa 3170 , Klebsiella Pneumoniae Atcc 700603 , Chip-Based Real Time Duplex Pcr Test For Simultaneous Detection Of Chlamydia Trachomatis And Neisseria Gonorrhoea Kit Along With Nucleic Acid Extraction Kit Compatible With It , Chip-Based Real Time Duplex Pcr Test For Simultaneous Detection Of Plasmodium Vivax And Plasmodium Falciparum Kit Along With Nucleic Acid Extraction Kit Compatible With It , Aso Latex Agglutination Test Kit , Crp Latex Agglutination Test Kit , Ra Latex Agglutination Test Kit , Newborn Grouping Daction Abo/Rh- Subgroups+K (48 Profiles) , Forward And Reverse Grouping-Diaclon Abo- D-Reverse Grouping 4*12Pcs(48 Profiles) , Rh Subgroups+K Daction Subgroups+K (48 Profiles) , Liss Coombs Cross Matching-Liss Coombs Igg+ C3d (4*12-288T) , Ahg Antisera (4*12) , Apheresis Kit (Sdp) S5l/ C5l (Platelet) With Acd Solution , Blotting Paper 1 Rim , Dat/Tdat (Igg C3bc3d) Column Card Antisera (1*12) , Eci A-Hcv Control , Eci A-Hiv 1+2 Control , Eci Hbsag Control , Elution Kit With Wash Buffer, Elution Solution, Buffer Solution Tris (1*10Ml) , Glass Slide 75Mm*25Mm (Pkt Of 50 Slides) , Micro Pipette Fixed/ Variable20 -200Ul Variable , Micro Tips 0.2-0.5 , Micro Tips 200-1000Ul , Micro Tips 2-200Ul , Micro Tips 5-10 , Monospecific Dat Card (Igg,C3d,Ctl) Card Column Agglutination Technology (1*12Ml) , Platelet Plasma Collection Kit With Single Needle With Acd Solution And Ns (Trima) , Storage Boxes 1000Ml , Test Tube Cleaning Brush Small , Plasmapheresis Kit (Pl1 Kit (Plasma Exchange Comtec Kit) With Acd Solution And Ns , Blue Cap Edta Vacutainer (6Ml) With Vacuum , Variable Single Channel Micropipettevarivol Ii Micropipette-100 Capcity (02-100 Ul) , Variable Single Channel Micropipettevarivol Ii Micropipette-1000 Capacity (10-1000 Ul) , Wbc Diluting Fluid 500Ml , Id- Diluent -Ii , Id- Diluent -I , Antigen Profile-I , Ag Profile-Ii , Ag Profile-Iii , Test Sera M, N, S, S, Fya, Fyb , Ih- Control For Id System , Dat Igg-Dilution , Id- Titration Solution , Id- Parical Rhd Typzng , Anti Body Screening Cells (3 Cells Panel- 3%) , Anti Body Identification Cells (11 Cells Panel- 3%) , Quality Control For Hiv, Hbsag, Hcv , Quality Control Negative For Hiv, Hbsag, Hcv , Quality Controlpositive For Hiv, Hbsag, Hcv , Quality Controlfor Syphills , Malaria Ag Detection Rapid Kit , Anti-A Antisera (Monoclonal) , Anti-B Antisera (Monoclonal) , Anti-Ab Antisera (Monoclonal) , Anti-D (Lgm) Antisera (Monoclonal) , Anti-D (Lgg) Antisera (Monoclonal) , Anti-D (Lgg + Lgm) Antisera (Monoclonal) , Anti-H Antisera , Anti-Ahg Antisera (Monoclonal) Igg + C3d , Anti-A1 Lectin Antisera , Anti-C Antisera , Anti-C Antisera , Anti-E Antisera , Anti-E Antisera , Anti Kell Antisera , Anti-Fya Antisera , Anti Fyb Antisera , Anti- M Antisera , Anti- N Antisera , Anti- S Antisera , Anti- S Antisera , Anti Lea Antisera , Anti Leb Antisera , Anti Lua Antisera , Anti Lub Antisera , Anti Jkaantisera , Anti Jkb Antisera , Anti Kpa Antisera , Anti Kpb Antisera , Anti Jsa Antisera , Anti Jsb Antisera , Nacl/Engyme Test Card Card Column Agglutination Technology , Papain Cystein Activated 1 % W/V , Ficinenzymes 1 % W/V , Blood Collection Tray , Cell Pack - Dcl , Lysercell Wdf , Lysercell Wnr , Sulfolyser Sls , Sulfolyser Sls , Cell Clean , Flurocell Wnr , Flurocell Wdf , Cell Pack – Dfl , Flurocell Ret , Fluorocell Ptl , Xn Check Low , Xn Check Normal , Xn Check High , Sodium Dihydrogen Phosphate Monohydrate (Nah2po4.H2o) (For Acidic Phosphate Buffered Saline) , Disodium Hydrogen Phosphate (Nah2po4) (For Alkaline Phosphate Buffered Saline) , Di-Thiothreitol (Dtt) , Chloroquine Phospahte , Sodium Hydroxide (Naoh) , Disodium Edta (Na2edta) , Glycine , Tris (Hydroxymethyl) Aminomethane , 3350 Mw Polyethylene Glycol (Peg) , Dry Ficin Powder , Dry Papain Powder , L-Cysteine Hydrochloride , Sodium Barbitol , 6.2 M Glycerol Lactate Solution , Copper Sulphate Anhydrus , Pooled Platelet Filter Bags , Dc-Screening I , Dc-Screening Ii , Liss/Coombs + Enzyme Test , Id-Cell Wash-P , Liquid Papain Solution
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 34
44.
Science and Technology #9416314 Technical Bid
Provision Of Axle Counter For Rusty Rail And Siding Tracks In Balance Yard Of Bab-Agd Section Of Jhansi Division. , Installation, Testingandcommissioningofmultisectiondigitalaxlecounter(Msdac)Completesystemasper Rdso Specification Ino.Rdso/Spn/176/2013 Version 3 With Latest Amendments Or Latest. Suitable For Commissioning Of Yard/Auto Section / Dual Detection (Dctc/Aftc With Msdac) . Msdac Should Have Facility To Reset Track Sections. Design Of Axle Counter Circuit Indoor Installation Testing And Commissioning Of Multi Section Digital Axle Counter (Per Unit), Note-1:1.Ifanyhousingisrequiredtokeepoutdoorequipment,Ithastobesuppliedwiththe Equipmentwithnoextracost (Mushroom Box Will Be Supplied By Cel And The Installation Will Be Done By Vendor. If Any Additional Qty Of Mushroom Box I.E. More Than 107 Nos. Is Required Then The Cost Of Supply & Installation For The Same Will Be Borne By Vendor).2.Maintenancefreeearthing(Supplyandinstallation)Fortrack Device/Mushroomhousingetctobedonebythecontractorifrequiredbysystemdesign.Noextra Cost/Paymentwillbemadebythisrailway:3.Automaticresettingfacilitiesthroughhardware /Software For Auto Resetting To Be |Provided By Contractor By His Own Materials For This No Extra Cost /Paymentwillbemadeby Cel.4.Msdacsystemnetworkingtobedonewithcentralcontrol Room.E1 Channel/Media Will Be Provided By Railway For This Purposefromnearestrailwaystation.5.Allotherhardwareliketpr,Extracardtomakedualdp, Modem,Ethernetswitchesetcifrequiredforcommissioningandfinaltracksectionpickupwillbe Supplied By Contractor, No Extra Payment Will Be Made By This Cel. 6 Separate Evaluator For Up And Down Line To Be Provided At Station/Rh As Decided By Railway Site Engineer. For The Communicationbetweenevaluatortoevaluator(Rhtostation)Quad/Ofclink(Darkfiber)Willbe Provided By Railway. Any Other Networking Equipment If Required Will Be Supplied By Contractor At No Extracost.7.Manualresettingthroughresetbox&Lvboxatstationtobeprovidedasper Requirement.Thedpconfiguration/Tracksectionmayvaryaspersite Note : Testingandcommissioning Will Be Done By Oem , Supplyofdoublewalledcorrugated(Dwc)Pipe/Ductwithassociatedcollarsetc.As Perrdsospecificationno.Rdso/Spn/204/2011Ver.1.1Amdt.1Orlatestanti-Rodent&Anti-Oxidant And Non Flame Propagating Type In 6 Meters Straight Length And Of Size 120 Mm Outer Dia,& 103.5 Mminnerdia.(Themanufacturers,Suppliersmustproducevalidislicenseandshouldbecertified Under Iso 9000 And Shall Submit Copy Of Certificate). One Couple With Suitable Rubber O-Ring Should Be Supplied With Every 6 Mtr Of Pipe Length.(The Total Quantity Of Above Items Is Equal To No. Of Pipes Supplied.) Dwc Pipe Shall Be Marked At Every 1 Mtr Length In Such A Way That Manufacturers Name, Vendor Name And Year Of Manufacture Can Be Easily Identified. (Inspection Agency:-Consignee). , Supplyofapparatuscase/Locationboxfullasperrdsodrg.No.Rdso/S-11500Or Latest, With E Type Lock And Key Ward No. 42, . The Key And Handle Should Be Supplied At The Rate Of One No. Per Four Apparatus Cases. The E Type Key Lock Is As Per Rdso Spec. Irs;S-30/64 Or Latest, Rdso Drg. No.Sa 3376/M Or Latest And Key Is As Per Drg. No. 3377/M Or Latest. (Inspection Agency:- Consignee). , Supplyofapparatuscase/Locationboxhalfasperrdsodrg.No.Rdso/S-11507Or Latest, With E Type Lock And Key Ward No. 42, . The Key And Handle Should Be Supplied At The Rate Of One No. Per Four Apparatus Cases. The E Type Key Lock Is As Per Rdso Drg. No.Sa 3376/M Or Latest And Key Is As Per Drg. No. 3377/M Or Latest. Note: This Item Includes The Supply Of 2 Nos E Type Lock Fitted On Both Doors, Along With Two Keys. (Inspection Agency:-Consignee). , Supply Of Phenolic Laminated Sheet, Resin Bonded, Grade P3 In Standard Size Of 1220 X 1220 X 10 Mm As Per Spec. No Is 2036 Of 1995 Or Latest. Test Report Of Manufacture To Be Supplied. (Inspection Agency:-Consignee). , Supply Of Dc-Dc Converter As Per Spec No. Irs:S- 96/2000 Or With Latest Amendment / Specification Rating 24Vdc, 10A Suitable For (Make- Statcon). (Inspection Agency:-Rdso). , Supply Of 1 X 10 Sqmm (Red/Black/Green) Multi Strand Pvc Insulated Copper Flexible Power Wire, And Test Parameters As Per Rdso Specn.No.Irs:S-76/89(Amnd.3) Or Latest. Colour Of The Wire Which Is Required Will Be Specified By The Engineer Incharge. (Inspection Agency:-Consignee). , Supplyofdisconnectterminalblockforfourconductorswithscrewingcage/Clamp Type, Sliding Switch Disconnect, As Per Rdso Spec.No. Rdso/ Spn/189/2004 Ver. 3.0 Or Latest, For Each Conductor Size Up To 2.5 Sq. Mm, Equivalent Of M6 Terminals. Each Terminal Block Equipped With Two Markers,Ontopandbottom,Anendplate,Twoendclampsandadequatelengthofrailsforfitting Terminal Blocks. (Inspection Agency:-Rdso). , Supplyofaraterminalblock,Madeofpbt,Asperrdsospec.No.Irs:S-75/2006 (Rev.2) Or Latest And As Per Drawing. No. Sa- 23741A (Alt.-4) Or Latest.(Inspection Agency:-Rdso). , Supply Of Cartridge Fuse Block, Made Of Pbt, As Per Rdso Spec. No. Irs: S-75/2006 (Rev.2) Or Latest And As Per Drawing. No. Sa- 23748 (Alt.-4) Or Latest. (Inspection Agency:- Rdso). , Supply Of Non Deteriorating Type, Round Head Type, Low Voltage Cartridge Fuse As Per Spec No Irs: S-78/2006 With Latest Amendments, 10A Rating Capacity. (Inspection Agency:-Rdso). , Supplyandinstallationofearthelectrodeasperstandardpracticeand Asperncr Drawing No. S&T/Const/6.4/97. It Includes Supply Of Gi Pipe Of 3M Length. It Includes Connecting The Earth Electrode To The Equipments Which Are Required To Be Earthed Including Digging Of Earth Pit 3 Mtr Deep And Fixing Earth Electrode Pipe, Casting Of Cement Concrete Enclosure With Cover (Cover As Perncrdrawingno.S&T/Const/6.3/97).Itincludesinstallation Of7strandgiwiresasearthlead Wires, Supported On Ms Flat Size 5Mm X 40 Mm, Soldering And Nut Bolt Both, One End Of Both Earth Lead Wire And Ms Flat To Earth Electrode And Other End To Location Boxes, Block Equipments, Power Equipments,Cablesheath,Signalsetc.Aspersiterequirementandasperinstructionsgivenby Engineer Incharge. (Inspection Agency:- Consignee). , Supply & Installation Of Rfid Based Electronic Cable Route Marker For S&T/Power Cable, Which Can Be Buried At A Depth Range 1.5 Meter. Make -Stanlay/3M (Model:1420 Xid) Or Similar. This Item Includes The Gps Marking Of Rfid Marker With The Help Of Rfid Locator Or App Based System. (Inspection Agency:-Consignee). , Supplyofcableroutetracerwithgpsenable10watttransmitter,Rechargeable Batterypackandmaincharger,Directconnectionlead10meterextensioncablewithallother Accessories. Make- Radiodetection/Stanley/3M Or Better. (Inspection Agency:-Consignee). , Supply Of Portable Maintenance Service Terminal For Installation, Testing And Maintenance Of All Networking Parameters, As Per Technical Specification. Make-Hp/Dell Or Superior. (Inspection Agency:-Consignee). , Supply,Installation&Commissioningof40lphcapacitydistilledwaterplant(De Mineralizer Plant) As Per Following Specification: 1) Stage-1: Reverse Osmosis Based Pre-Treatment 2) Stage-2:Indianresinorsimilar3)Outputtreatedwaterperhourwillbe40ltrs(+/-10%)Andis Suitable For 2V 80Ah & 300Ah Batteries 4) Output Treated Water Per Hour To Be Between 6.0 To 8.0 Ph Value 5) 18 Pp Filters And 12 Carbon Filters For Free Filtration Are To Be Supplied Along With The System. Warranty Period Shall Be 12 Months Minimum From The Date Of Commissioning Or 18 Months From The Dateofsupplywhicheverisearlier,Materialshallbesuppliedalongwithawarrantycertificate. Installation Is To Be Done At Different Specified Locations In Jhansi Division. Accepted Make- Supertronics/Paramount(Nrdm40) Or Equivalent. (Inspection Agency:-Consignee). , Installation And Wiring Of Dc-Dc Converter For Item No. 7 Of Sch A .(Make- Statcon Or Similar) . , Laying Of S&T Cables Of Various Cores/ Pairs/ Quads In Trenches/ Gi Pipes/ Rcc Pipes/ Dwc Pipes Etc. As Per The Site Requirement And As Per Approved Cable Route Plan. This Also Includes Layingofcablesintrackcrossings&Roadcrossings.(Cableswillbemeggeredbeforeandafterits Laying By Contractor Under Supervision Of Railway Representative And He Will Submit The Meggering Report Of Each Testing). Length Of The Cable Laid Includes The Length Of The Cable Coiled For Termination Purposes. , Digging Of 1.20 Meter Deep And 0.3 Meter Wide Trenches Including Clearing Of Roots Of Trees And Bushes And Temporary Obstruction On The Selected Route And Cable Route Plan. It Includes Covering Of Cable Laid In Trench By Loose Soil For A Layer Of 50 Mm Thickness Approximately. Note:- In Case Where Digging Of Trench Up To 1.20 Meter Depth And 0.3 Meter Width Is Not Possible Or Bigger Sizetrenchisrequiredtolaymorecablesorloosesoil/Muckisencountered,Thedepthcanbe Reduced/Increasedasperdirectionsoftheengineer-In-Chargeoftheworks,Thepaymentwillbe Decreased/Increased Proportionate To The Depth & Width Of Excavation Compared To 1.20 Meter Deep And 0.3 Meter Wide In All Type Of Soft Soils Including Soft Rock. , Digging Of 1.20 Meter Deep And 0.3- Meter -Wide Trenches Including Clearing Of Roots Of Treesandbushesandtemporaryobstructionontheselectedrouteandcablerouteplan.Itincludes Covering Of Cable Laid In Trench By Loose Soil For A Layer Of 50 Mm Thickness Approximately. Note: In Case Where Digging Of Trench Up To 1.20 Meter Depth And 0.3 Meter Width Is Not Possible Or Bigger Size Trench Is Required To Lay More Cables Or Rocky Soil Is Encountered, The Depth Can Be Reduced / Increased As Per Directions Of The Engineer-In-Charge Of The Works, The Payment Will Be Decreased/Increased Proportionate To The Depth & Width Of Excavation Compared To 1.20 Meter Deep And 0.3 Meter Wide In Rocky Soils. , Cross Trench For Identification Of The Route Of Existing Signaling And Telecom Cables. , Horizontal Direction Drilling (Hdd)/Trenchless Digging/Machine Drilling Without Damage To Surface Road /Track For Laying/Insertion Of Hdpe/Gi/Dwc Pipe. The Bore Shall Be Done At The Depth Of Minimum1400mmfromthegroundlevel.Thegroundlevelshallbeconsideredignoringthebank Heightofthebankoftheroad.Note:-Dwc/Hdpe/Gipipesupplyisnotcoveredunderthisitem. Contactor Shall Provide All Material Required For Work And Adequate Nos. Of Labours For Proper Laying Of Cables Into The Bore. Cable Shall Be Laid Cautiously So That It Should Not Get Damage Due To Rough Handling & Pressure On Cable. , Horizontal Boring/Manual Moling Without Damage To Surface Road /Track For Laying/Insertionofdwc/Gi/Hdpepipe.Theboreshallbedoneatthedepthofminimum1400mm From The Ground Level. The Ground Level Shall Be Considered Ignoring The Bank Height Of The Bank Of The Road. Note:- Dwc/Hdpe/Gi Pipe Supply Is Not Covered Under This Item. Contactor Shall Provide All Materialrequiredforworkandadequatenos.Oflaboursforproperlayingofcablesintothebore. Cable Shall Be Laid Cautiously So That It Should Not Get Damage Due To Rough Handling & Pressure On Cable. Payment Of Boring Shall Be Made Only After Dwc/Hdpe/Gi Pipe Is Laid In The Bore. , Cement Concrete Work For Miscellaneous, Unscheduled Items In Ratio 1:3:6 Of Cement, Coarse, Sand And Aggregate Item Includes Excavation, Ramming Of Cc By Using Vibrator, Curing And Plastering With Cement And Sand Mixture In Ratio1:4 (Aggregate Will Not Exceed Beyond 3.8Cm).The Aggregate Cement And Sand Will Be Supplied By Contractor. , Cutting Of All Types Of Platforms/Road Crossing And Trenching And Excavation To A Width Anddepthof300mmx300mm,Layingofdwc/Hdpe/Gipipeinthetrenchandrefillingand Concretingitafterwardsasperoriginalcondition.Inhardrockygroundarea,Cableswillbelaid Normally On Layer Of Soft Earth Of 0.05 Mtrs Thickness Previously Deposited At Bottom Of The Trench. The Cutting To Be Filled And Finished With Cement/Concrete, As Per The Rdso Drawing No. Sdo/ Cable Laying/008, Issued Vide Rdso Document No. Rdso/Si/G/2010 Version 1.1 Dated 04.02.2014 Or Latest. , Placingofdwc/Rccpipesalongwithcollarsintrenchesatplacesoftrackandroad Crossings, Platform Cuttings Etc. Also For Straight Cable Laying (Cable Laying Is Covered Separately). , Laying And Fixing Of Medium Class Gi Pipes 100 Mm Dia (4.5 Mm Thickness) As Per Is 1239 ( Part 1) 2004 Or Latest With Coupling On Culverts/Bridges, Perforated At A Distance Of 20 Cm Or Less With 10 Mm Dial Hole, Or At Any Other Locations As Decided By Site Engineer.The Gi Pipe Is To Be Filledwithchatteredcompound.Itincludessupplyofallmaterialrequiredforfixingarrangement. Contractor Will Also Supply Flexible/Corrugated Hdpe Pipe At The End Of Gi Pipe To Protect The Cables Fromsharpedgesandsuddenbends.Thelayingandfixingtobedoneasperrdsodrawingsno. Sdo/Cablelaying/011Andsdo/Cablelaying/012Issuedviderdsodocumentno.Rdso/Si/G/2010 Version 1.1 Dated 04.02.2014, Or Latest , Earthing Connection And Soldering Of Cable Armour. (Unit:Per Cable=Per Conductor) , Terminationofoutdoorcables(Maincables/Tailcables)At/Ara/Disconnecttype Terminalsprovidedinapparatuscases,Cableterminationrackinrelayroom,Stationbuilding, Generatorroometc.Theitemincludesdressingofcablesandwireswithdressingthreadsasper Standard Practice. All Material Required For This Item Will Be Supplied By Contractor. The Outdoor Cable Shallbeterminatedinrelayroom,Ipsroom,Asmroometc.Undersupervisionandinstructions Issued By Engr. Incharge Of The Work. , Fixingofara(M-6)Terminals/Screwlessconnectors/Modulardisconnectterminal Blocks And Fuse Blocks On Phenolic Laminated Sheets And Fixing By Stainless Steel/Brass Nuts & Bolts. This Includes Provision Of Two Additional Holes On The Board On Either Side For Cable Conductor Entry. Theworkshallbecarriedoutaperinstructionsofrailwayengineerincharge.(Supplyofallabove Materials Has Been Covered Separately). , Lettering And Numbering Of All S&T Gears Like Signals, Loc. Boxes, Pt. Machines, Tljbs, Block Joints Etc. Each Item To Be Taken As One Unit. , Cable Insertion In Old Locations /Station Relay Room /Cable Pit Etc As Per Site Engineer And Filling With Sand And Plastering The Same. Note: All The Sundry Material Except That To Be Supplied By Railways Will Be Supplied By The Contractor. , Drawingofwiringcircuitina-3Sizesheetinautocad.(02Setsphotocopy&01Set Tracing With Soft Copy) . , Preparation & Submission Of Cable Route Plan Of Main & Tail Cables , Cable Cordage Plan, Locationparticulars,Ctrackparticulars,Meggeringreport,Earthresistanceparticulars,Traction Bonding Diagram And Any Other Drawing / Particulars Required In Auto Cad In Minimum A3 Size Each Sheetshouldhaveablockforsignatureofrailwayofficialsaswellasblockforsignaturethefirm, Where Signature Of Shall Be Put Up By The Authorized Signatory Of The Firms. The Name Of The Work As Begivenbytherailwayshallwrittenoneverysheetundertheworkcolumn.Onecompetesetof Tracings And Four Sets Of Copies Of Complete Above Detailed Particulars / Drawing Along With One Cd To Be Supplied By The Contractor In Thick Plastic Folders. , Development And Preparation Of Sip, Swrd/Gwrd/Swr Etc Based On Existing Sip/Esp.(For Station/Lc Upto 4 Lines) [Job=Per Stn/Lc , Excavation,Casting,Curingoffoundationandinstallationanderectionofapparatus Case Full (Apparatus Case Foundation As Per Ncr Latest Practice) With Contractors Own Frame, Cement And Other Material In The Ra Tio 1:3:6. E Type Lock To Be Supplied And Installed With Apparatus Case. This Includes Filling Of Location Foundations With River Bed Sand And Plastering On Top With A Mixture Of 1:4 Of Cement And Sand. It Covers Fixing Of Lamp Holder, Switch And Lamp Etc. In Apparatus Case. , Excavation,Casting,Curingoffoundationandinstallationanderectionofapparatus Case Half (Apparatus Case Foundation As Per Ncr Latest Practice) With Contractors Own Frame, Cement And Other Material In The Ra Tio 1:3:6.E Type Lock To Be Supplied And Installed With Apparatus Case. This Includes Filling Of Location Foundations With River Bed Sand And Plastering On Top With A Mixture Of 1:4 Of Cement And Sand. It Covers Fixing Of Lamp Holder, Switch And Lamp Etc. In Apparatus Case. , Fabrication And Fixing Of Phenolic Laminated Sheet Of Grade P3, Minimum 10 Mm Thick, Asperapparatuscasediagram/Plan,Inlocationboxbyprovidingallfixtureslikeara/Disconnect Terminals, Fuse Blocks, Fuses, Relays On Square Bars Etc. Including Fixing Of Pvc Coated String Rods At The Back Side For Cable Support With Contractors Own Material Like Iron Angle, Nuts, Bolts Etc. The Iron Angle For Fixing Shall Be Minimum 3 Mm Thick. This Also Includes Fixing Of Teak Wood Shelf Minimum 25 Mmthickforholdingtrackcircuitequipments.Theworkshallbedoneasperinstructionsofrly Engineer At Site. (Apparatus Case Full) , Fabrication And Fixing Of Phenolic Laminated Sheet Of Grade P3, Minimum 10 Mm Thick, Asperapparatuscasediagram/Plan,Inlocationboxbyprovidingallfixtureslikeara/Disconnect Terminals, Fuse Blocks, Fuses, Relays On Square Bars Etc. Including Fixing Of Pvc Coated String Rods At The Back Side For Cable Support With Contractors Own Material Like Iron Angle, Nuts, Bolts Etc. The Iron Angle For Fixing Shall Be Minimum 3 Mm Thick. This Also Includes Fixing Of Teak Wood Shelf Minimum 25 Mmthickforholdingtrackcircuitequipments.Theworkshallbedoneasperinstructionsofrly Engineer At Site. (Apparatus Case Half) , Paintingoftwocoatsofenamelpaintoveronecoatofredoxideprimerafter Scrappingandcleaningofthesurface.Painttobeofreputedmakeasian/Dulux/Bergerorsimilar. App. Cases Inside And Outside To Be Done By Silver Colour. (Apparatus Case Full) , Paintingoftwocoatsofenamelpaintoveronecoatofredoxideprimerafter Scrappingandcleaningofthesurface.Painttobeofreputedmakeasian/Dulux/Bergerorsimilar. Apparatus Cases Inside And Outside To Be Done By Silver Colour. (Apparatus Case Half)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
45.
Health and Family Welfare #9345222 Technical Bid
Tender For Supply Of Drugs/Surgical And Equipment, Medicine During The Year 2024-25- 1 Type c category equipments, furniture, implants and medicines 2 Autoclave Surgical drum SS-Size 15*12 approx 3 Autoclave Surgical drum SS-Size 9*9 approx 4 Autoclave Surgical drum SS-Size 11*9 approx 5 Autoclave Surgical drum SS-Size 11*5 approx 6 OT Trolly (Dressing) 7 Supra Pubic Trocar 12 No 8 Supra Pubic Trocar 8 No 9 Supra Pubic Trocar 14 No 10 Tooth Forcep & Non Tooth Forcep Midium Size 11 Suture Cutting (Micro) 12 Mayo Scissors (Carved) Midium 13 Nebular (Bone Cutter) 14 Sharp Scissors 9.0ml 15 Tissue Cutting Scissors Carved Midium 16 Mosquito artery big Size 17 Mosquito artery Medium artery 18 Gigli Saw vial 19 Bone Saw Big 20 Hegars Dilator set 21 Biopsy Gun 22 H.B Skin grafting handle 23 Bull dog 24 clamp 25 Suction Cannula disposable 26 O.T. Light double dome 27 Cautery Pin 28 Triway catheter No 20 29 Urinary Cathetor No 12, 30 Urinary Cathetor No 14 31 Urinary Cathetor No 10 32 K-90 Catheter 33 Tommy Syringe 34 Hperdomic Needle No 16 35 Hydrogen Peroxide (500ml) 36 Small Tooth 37 Non Tooth forcep 38 Bone Vax 39 Senetizer 40 Disposable Syrienge 2ml 41 Disposable Syrienge 5ml 42 Disposable Syrienge 10ml 43 Disposable Syrienge 20ml 44 Uro Bag 45 Adhesive Tape Roll 4 46 Paper Adhesive Roll PER Pack 47 Gloves No 6.5 48 Dressing Disposeble Gloves 49 Spinal Needle 50 Ven flow No 20 51 Suction Tube 52 Oxygen Key 53 Oxygen Flow Meter Set 54 Vicryl 3.0 Round body 55 Vicryl 2.0 ½ cr RB Needle 30mm 56 Vicryl 3.0 ½ cr RB Needle 22mm 57 Vicryl 3.0 ½ Cutting Needle 58 Vicryl 1 ½ cr RB Needle 36mm 59 Vicryl 1.0 ½ cr RB Needle 30mm 60 Ethilon 1. 0 ½ cutting Needle 36mm 61 Ethilon 2. 0 3/8cutting Needle 36mm 62 Ethilon 3. 0 3/8cutting Needle 36mm 63 Silk – 1.0 64 Silk – 2.0 65 Silk – 3.0 66 Hydrogen peroxide 6% 400ml 67 Butroclot solution 68 Drain sheet (Currugeted) 69 Sumag Ointment 70 Dis. Needle 16no, 71 K90 Katheter 72 3 way stop cock with extension line 73 Needle 24x1 ½ 74 Lignocain 4% vail 75 Endotrachial Tube 7.5cm 76 Endotrachial Tube 8.5cm 77 Poly Propylene 2.0 1/2 cr RB Needle 30mm 78 Surgical Cap 79 Chair S TYPE 80 Abdomans Spange 20 X20 81 Tailar Scisor 82 Feetal Doplar DIGITAL 83 Nebulization Machine 84 Giuco Meter 85 BP Instrument standmodal 86 BP Instrument Digital 87 Palse oximeter tabel Top 88 fogging Machine 89 Digital Tharma meter 90 Baby Tray 91 Autoclav drum 92 Gyser 20 LITER isi MARK 93 Wheel Chair 94 Digital Watch 95 O2 Flow Meter 96 Kideny Tray 8 97 Doctor Chair 98 Sizzer 8 99 Epigiotomy Sizzer 100 Hand Wash 500 ml 101 dispossable syrienge 50ml 102 dispossable syrienge 20ml 103 dispossable syrienge 10ml 104 dispossable syrienge 5ml 105 dispossable syrienge 3ml 106 dispossable syrienge 2ml 107 Follyes Cathetar 16 No 108 Endotrachial Tube 2cm 109 Endotrachial Tube 2.5cm 110 Endotrachial Tube 3cm 111 Endotrachial Tube 3.5cm 112 Endotrachial Tube 5cm 113 Endotrachial Tube 6cm 114 Endotrachial Tube 7cm 115 Endotrachial Tube 7.5cm 116 Endotrachial Tube 8.5cm 117 Endotrachial Tube 8cm 118 Air Pressure Line 119 O2 mask 120 NRBM Mask 121 Flatus Tube 122 Glucometer Strip 123 Albumin Strip 124 UTP Kit 125 Celispaid 126 Senitary Pad 127 Ambu Bag Adult 128 Ambu Bag pediatric 129 mettress 4 (6 x3) fom with cover 130 Baby Diper 131 Ventilator Tube 132 Pediatric dreep set 133 IV Stand SS 4 Wheel 134 Oxygen Key 135 Sterlizer Medium Size 136 Chair office 137 Steel Tray with Cover 138 Nebulization Mask 139 Refrigerator 180LIT 140 Strature with wheel 141 Lade Aprone 142 Nasalprobe Child 143 Nasalprobe Adult 144 Mayo sizzer 145 Fine tooth Forcep 146 tooth Forcep big 147 Step StoolMS 2 Step 148 Pattela Holding Forcep 149 Bone Cutter 150 Giggli Wire 151 T- Handel 152 Tubalring 153 Mucous Extractor 154 Caord clamp 155 Baby Tag 156 Romo Vac sizes of10, 12, and 14 FGbellow unit capacity is 800 ml.curved Needle Length is 175 cm. 157 Pules oximeter tabal Top 158 Weight Machine Adult 159 Enfusion Set 160 PPE Kit 161 Feeding Tube 5 no 162 Feeding Tube 6 no 163 Feeding Tube 7 no 164 Feeding Tube 8 no 165 P.M.O. Line 166 Adult Nosal Prong 167 Water Cooler 40 Litter 168 Urine polmale 169 Tuning fork (256) 170 Stop Watch 171 Percussion hammer 172 omce Table 173 Office Dustbin 174 LED Torch 175 Iron Almiraha 6 176 DigitalClock 177 FUJI PRINTER DRY IMAGING FILMOBX 10 DIGITAL X-RAY FILM 178 DISTAL REDIUS T,T OBLIQ PLATE (SIMPLE) 179 3.5 MMLOCKING CLEVICALPLATE ( 5 TO 8 HOLE ) 180 3.5/2.7 MMLOCKING CLEVICAL SUPERIALPLATE (5 TO 8 HOLE) 181 ADWANTEG SYRING 182 Illizarov Set 183 Modular Bipolar Set (1 Cese) 184 Blood Bank Refrigerator Technical specifications: Blood bank refrigerator1- Blood bank refrigerator – capacity 100 blood bags or more with two or more shelves.... 2- Inner chamber made of stainless steel, outer chamber made of powder coated steel sheet with high quality insulation material between the walls.3- Microprocessor based temperature controller with preset temperature 4 degreecentigrade plus minus 1 degree centigrade .and digital temperature display. 4- 50 htz 220-240 volts Ac power supply (single phase power supply in India). 5- Audio-visual alarm for low (less than 2 degree centigrade) and high (more than 8 degree centigrade) temperature.. 6- 7 day circular temperature chart recorder- in built.. 7- Air circulation fan. 8- Light bulb inside chamber. 9- Auto defrost mechanism or frost free, CFC free. 10- In built line voltage corrector 11- Vendor has to support the specifications with manufacturer’s brochure failing which offer may be rejected. Vendor has to demonstrate the equipment at BHEL General Hospital, Hyderabad within specified time limit, if asked for; failing which offer will be rejected. 185 Blood Celll Counter Impedance method for WBC, RBC and PLT counting Cyanide free reagent for hemoglobin test21 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR, P-LCC3 histograms for WBC, RBC and PLTPrediluted mode ≤20μL | Whole blood mode ≤9µL , 60 samples per hour10.4 inch TFT Touch ScreenChinese, English, Spanish, Portuguese, Russian, French, Bahasa, IndonesiaUp to 400,000 results including numeric and graphical information LAN Port supports HL7 protocol | Support bi-directional LIS4 USB ports (for external printer, software upgrade, barcodereader, external WIFI, keyboard and mouse), LAN port (1)Thermal recorder, 50 mm wide paper, various printout formats External printer optionalTemperature: 15°C~35°C | Humidity: 10%~90%Air pressure: 70kPa~106kPa(100V-240V)±10% through online UPS (rating 1 KVA)≤180VA | (50Hz/60Hz)±1Hz ,410(L) x 300(W) x 400(H) mm ; 20Kg 186 DefibrillatorTECHNICAL SPECIFICATION OF DEFIBRILLATORDESCRIPTION of Function• Defibrillator is required for reviving the heart functions by providing selected quantum ofelectrical shocks with facility for monitoring vital parameters.Operational Requirements• Defibrillator should be Bi- Phasic, light weight and latest model• Should monitor vital parameters and display them• Should print the ECG on thermal recorders.• Should work on Manual and Automated external defibrillation (AED) mode. Manualselection up to 270 J.• Should be capable of doing synchronized & asynchronized cardioversion• Can be operated from mains as well as battery• Should have defibrillator testing facilityTechnical Specifications• Should be a Low Energy Biphasic defibrillator monitor with Recorder, having capability toarrest allarrhythmia within a maximum energy of 360 Joules• Should monitor ECG through paddles, pads and monitoring electrodes and Defibrillatethrough pads and paddles.• Should have Automatic Lead switching to see patient ECG through paddles or leads• Should measure and compensate for chest impedance for a range of 25 to 150 ohms• Should have a built in 50mm strip printer/ thermal recorder• Should have charging time of less than 3 seconds for maximum energy. Charging indicatorshould be there.• Should have bright electroluminescent display for viewing messages and ECG waveform of4 seconds• Should have external & internal paddles with paddles contact indicator – for good paddlecontact. Single Adult and pediatric paddles should be available.• Should have event summary facility for recording and printing at least 250 events and 50waveforms.• Should be capable of printing Reports on Event summary, configuration, self test, batterycapacity etc• Should have facility for self test/check before usage and set up function• Should have SP02 and NIBP integrated facility• Should have user friendly color coded operationEnvironmental factors• The unit shall be capable of operating continuously in ambient temperature of 10 -500 C andrelative humidity of 15-90%• The unit shall be capable of being stored continuously in ambient temperature of 0 -500Cand relative humidity of 15-90%• Shall meet IEC-60601-1-2: 2001(Or Equivalent BIS) General Requirements of Safety forElectromagnetic Compatibility.Power Supply• Power input to be 220-240VAC, 50Hz. Power cable should be fitted with Indian plug andadapter.• Resettable overcurrent breaker shall be fitted for protection• Should have a Rechargeable Battery capable of usage for at least 90minutes or 30discharges. 187 Electrolyte Analyzer Method Sample Speed :-Multi-Biosensor TechnoloTechnology 60-120µlISE ≥ 80 tests / hour Printer Inner Thermal Printer Expand FunctionAmbient Conditions PowerPower Requirement RS232 & COM Connector, Computer and Barcode reader available0-40°C, Relative humidity ≤ 85% AC 80V ∼ 260V, 50-60Hz, ≤ 80WEarth Voltage <5V, Online UPS (230V)with isolated, transformers - 0.5 KVAParameters K+ Detection Range (mmol/L) 0.50 ∼ 20.00 Precision (CV)≤1.0% Resolution (mmol/L)0.01MeasureScope & Precision Na+ 15.0∼200.0 ≤1.0% 0.1 Cl- 15.0∼200.0 ≤1.0% 0.1 Ca+ 0.10∼200.0 ≤1.0% 0.01 pH 4.00∼9.00 ≤1.0% 0.01 188 Elisa Reader WasherSpecifications for Microplate (ELISA) Reader1. Should have minimum wavelength range of 400–750 nm and photometric range of 0.0–3.5 OD2. Should have linearity of ≤1.0% from 0.0–2.0 OD; ≤2.0% from 0.0–3.0 OD; accuracy of ≤1.0%or 0.010 from 0.000–3.000 OD at 490 nm; precision of 1.0% or 0.005 OD from 0.0–2.0 OD;1.5% from 2.0–3.0 OD and resolution of 0.001 OD3. Should have minimum 8 filter wheel capacity with 415, 450, 490, 595, 655, and 750 nm includedfilters4. Should have minimum 3 speed plate shaking with adjustable duration of 0–999 sec5. Read time should not be more than 6 sec at single wavelength or 10 sec at dual wavelengths6. Should have onboard graphical thermal printer and USB2 interface with PC or Mac datastations for data output7. Should be able to store data for over sixty assay protocols8. System should come with a comprehensive software package allowing colorimetric andturbidimetric analyses, as well as report analysis for raw data, absorbance, limit, matrix,normalization, and curve fit9. Software should have the functionality of flexible template creation for any microplate formatup to 1,536 wells10. Software should be either license free or license for minimum 5 systems should be providedSpecifications for Microplate washer Automatic washer compatible with strips and 96-well microplates that have flat-, U-, or Vbottom wells. Programmable needle positions (horizontal or vertical) to an accuracy of 0.1 mm for bottomwashing, crosswise aspiration, and overflow washing. Dispensing speed control A plate shaking option to help minimize bubbles and adherence of liquid to well sides. Wash bottle sensor to detect high waste liquid levels Up to 75 programmable washing sequences Easily removable 8- or 12-way manifolds Easily accessible manifold interior for maintenance Removable and autoclavable plate carrier An aerosol protection cover Integrated vacuum and dispensing pumps to ensure accurate and quiet washing and toeliminate the need for external pumps. Residual well volume should be < 6 µl Wash bottle volume should be 2000 ml Soak time in strip mode 0-9.9 sec and in plate mode 0-59 minutes. Should come with 8-way manifold and 12-way manifold should be quoted in optional. On-board software should be capable of storing up to 110 wash protocols. Operating temperature 15-40 °C. Dimensions (WxDxH) not more than 35x43x20 cm Both instruments should be of from same manufacturer 189 Semi-Automatic Biochemistry AnalyzersTechnical Specifications Human Machine Interface Touch Panel / Key Board / MouseLinear Measurement Range 0.000 to 3.000 Absorbance Units (A)Photometric Accuracy ±2% or 0.007 whichever is higher, from 0 to 2.0A, ±3% from 2.0A to 3.0ADrift <0.003A/hr.Optical Measurement Silicon Diode Filters Type of filterWave LengthHalf Bandwidth Filter SelectionFlow cell TypeFlow cell volumeSipping Volume Sipping Mode Cuvette Volume : Interference: 340,405, 450, 505, 546, 578, 630+2 Optional: ±2nm: By Stepper motor: Stainless steel body & Quartz Window: 32 μι: 300 to 1000 μι: Automatic by specially designed Peristaltic Pump: 500 μι Temperature of Cuvete/flow cell Block Method Temperature Light Source Warm up Time Display Printer Memory CPUBuilt in Incubator : By Peltier effect: 25°C, 30° C and 37° C: 6V/10W Tungsten Halogen lamp: 90 Sec.: 7 TFT Display 300 x 930: Built in 55 mm, stationary head graphical thermal printer: DDR, & DRAN 1 GB, Flash 256 MB: ARN Cortex A8720 MHz: 2 Place for coagulation reagent | 15 Place for coagulation Cuvette 5 Place for test tubes Storage Capacity 2000 Open tests with 30 QC results/test (Normal and Abnormal controls)200000 Patient results with patient ID and GraphAnalysis Mode 1 point, 2 point (Sample blank) | Fixed time | Kinetic | CoagulationConcentration calculation : By factor or by standard Blanking PortPower WattageVoltage Operating Position : Water, Reagent: 4 USB, LAN Rj45: 100 Watts: 110-240 Volts ±10%, 50-60 Hz: On horizontal, flat, rigid and vibration free surface Operating Conditions Temperature Relative Humidity : from +18° C to 35° C: up to 85% Storage Condition Temperature Relative Humidity EnclosureSize (cm) Weight : from 10° C to + 60° C: up to 85%: ABS Fire retardant: 30X38X13.5 (LxBxH): 7.0 Kgs. (Approx) 190 Suction MachineSpecificationsPortable suction unit: size 38x17x28.5cm, weight 5.1kgDescription (e.g.: model Vario A/C, manufacturer Medela)Technical specifications: SUCTION MACHINE with pump:- Power supply: 230-240V/50Hz- Vacuum capacity: 18 litres/mim- Maximum depression: -75kPa (-563mmHg)Vacuum is created by a plastic piston and cylinder system, with four vacuum-creatingmodules (QuatroFlex™ technology).The membrane vacuum regulator permits accurate vacuum settings.Double overflow-protection system (bottle and pump).Working temperature range: +5 to +40°C. 191 Microscope Technical SpecificationsSl Name TechnicalSpecsquotedby bidderBiddersDeviationif any3.1 Body :Binocular, sturdy, stable base body with focus adjustment controls3.2 Eye piece :Paired, high quality, (the image of the object as seen throughthe binocular eyepiece should be well defined centrally in at least 2/3field of view), achromatic, widefield, 10x without inbuilt pointer. Theeyepiece should be aplatanic and have a minimum field number of 18.Diopter adjustment must be present on one/ both eye pieces or on theeye piece tube3.3 Objective :Three objectives10x,40x,100x,10x and 40x objectives should have numerical apertures of 0.25 and 0.65respectively and should be of spring loaded type or otherwise.100x should have numerical aperture of 1.25 and should be of oilimmersion and spring loaded type. Suitable prominent marking should beprovided on 100x for easy identification.Unbreakable containers to be provided for storing the objectives. Allobjectives should be wide field, achromatic and parfocal.Making for the Objectives :Each objective should be engraved with thefollowing informations:-• Name of the manufacturer• Magnification and numerical aperture, for example, 10x/0.25• 100x objective should be engraved with the word ‘Oil’in changing from one objective to another or reintroducing the sameobjective by rotation of the nosepiece, the object at the center of thefield should not appear displaced by more than 0.02 mm in the objectplane in any direction.3.4 Nose piece:Revolving nose piece to accommodate a minimum of threeobjectives with click stops. It should be provided with ribbed grip for easyrotation mounted on a precision ball bearing mechanism for smooth andaccurate alignment. Extra ports if any should be fitted with dust proofmetallic/ebonite caps.3.5 Stage Uniformly horizontal, mechanical stage having dimensions oflength 140 mm (+/- 20mm) with fine vermier graduations (minimumreading accuracy of 0.1 mm). the stage should be provided with springloaded slide holder for exact positioning of specimen/ slide. It should bedesigned with convenient sub-stage vertical coaxial adjustment for slidemanipulation. The stage should have ball-bearing arrangement to allowsmooth travel in transverse directions i.e. 80 mm (+/-5mm) and front toback direction, 50mm (+/-5mm)3.6 Sub-stage condenser:Abbe-type condenser, numerical aparature (N.A.)1.25 focusable with rack and pinion arrangement incorporating anaspherical leps and an iris-diaphragm. The condenser should have a filterholder and removable/ swing in/ out blue filter (suitable for bright fieldMicroscopy).3.7 Sub-stage illuminator: 1.The system should have a build-in variable lightsource (Illuminator). This light source should have a 20 W, 6 V Halogenlamp. The circuitry for the light source should include a constant voltagesupply. The system should be provided with a step down transformer andan on-off switch and intensity control. The lamp should be provided witha lamp socket which has the facility for easy replacement of the bulb,2. Power Supplya. Voltage 220 V, 50 Hz ACb. Should have one on-off power switch, 3 core power cord with a 3 pointmale plug.3. The system should have an inbuilt protective/ safety device towithstand fluctuations of voltage from 140 V to 280 V4. A plano-concave mirror in fork mounting should be supplied whichwould be attachable to the base for field use. (where power is notavailable).5. The fuse for the halogen lamp should be easily accessible to theoperator6. The Illuminator should have a build-in field diaphragm for Kohlerillumination3.8 Eye piece tubes:Binocular eye piece tubes, inclined at 45 degrees,rotatable through an angle of 360 degrees, having inter-pupullarydistance range of 54-74 mm or wider, covering the above mentionedrange3.9 Focusing knob:Co-axial coarse and fine focusing knobs capable of smoothfine focusing movement over the full range of coarse travel. The finefocusing movement should have sensitivity of two microns or less (finer)over the entire coarse focusing stop safety arrangement should beprovided.3.10 General 1.All optical parts including objectives, eye pieces and prismsshould have anti-reflective coating which also gives anti-fungal property.2.All metallic parts should be corrosion-proof, acid-proof and stain-proof3.Working manual should be provided with each microscope4.A bottle of at least 25 ml immersion oil, a roll of lens tissue paper andlens cleaning solution (100 ml) should be provided with each microscope.5.One no.of anti static cleaning brush should be provided with eachMicroscope for cleaning purpose.6.Each Microscope should be supplied with Blue filters. The Blue filtershould be packed in the ox and not fixed on the Microscopes. 4 System Configuration Accessories, spares and consumablesSl Name TechnicalSpecsBiddersDeviationquotedby bidderif any4.1 System as specified-4.2 Each microscope should be supplied with spare parts as under:•100x oil immersion objective (as per the specifications given under B3) –one.•Halogen bulb, (6volts, 20w) – 6 Nos.•Fuses – 6 Nos.4.3 All consumables required for installation and standardization of system tobe given free of cost. 192 Truenat Machine 3. Equipment and site preparationAn essential step of the implementation process is the selection of instruments to fit theneeds of the testing algorithm, anticipated workload and intended setting of use theTruenat TB tests. Laboratories should select the appropriate number and models ofTruelab micro PCR Analyzers to match anticipated demand (see Table 4 for estimationof throughput). Note that the ability of a testing site to utilize all of the capacity ofa workstation may not be an important factor for selecting Truenat TB testing sites, especially considering that the Truenat TB test isdesigned to be placed at peripheral microscopycenters.All instruments must be documented to be “fit forpurpose” through testing with known positive and/or negative material prior to commencing testingof clinical specimens.Planning for service and maintenanceTruelab and Trueprep instruments require minimalpreventive maintenance as per the manufacturer.For an example of a preventive maintenance logthat shows routine daily and monthly activitiesas well as ad hoc activities to be conducted asnecessary, see Annex 4.The manufacturer offers warranty packages forequipment service and maintenance includingthrough its growing network of in-country serviceproviders. Annual warranties that providecomprehensive service and maintenance includingon-site visits are available through the Stop TBPartnerships Global Drug Facility (GDF); seethe GDF Diagnostics Catalog for more details.Countries planning to implement Truenat shouldinform the manufacturer in advance to allow themanufacturer to plan as needed for expansion ofits network of service providers.Site preparation and assessment of readinessAs part of the situational analysis, each of theselected testing sites will have been evaluatedfor suitability for conducting Truenat TB testingusing a standardized checklist (see Annex 6). Keyinfrastructure and operational considerations forsite preparation include:• Power: In-built batteries in both devices allow fortesting without power for up to 8 hours; deviceswill not allow for a cycle to start if battery poweris too low. Batteries are expected to last fiveyears. Note that power is still required to chargebatteries: recharging time is approximately 4hours for the micro PCR analyzers, 9 to 10 hoursfor the Trueprep device and 4 to 6 hours for themicro printer. Use of instruments while chargingis possible, when the electrical socket is wellgrounded. The devices are able to operatewithin the 100-240 voltage range; no additionalvoltage stabilization is required in settings withinstabilities or low voltage. Solar panels maybe a solution for settings without any access topower (see Box on specifications). Power mayalso be required to possibly cool the storageroom for test chips; as described below, chipsshould be stored at ≤30°C.Activities at a glance□ Select, procure, install and set-upequipment□ Verify the instruments are fit for purpose□ Arrange for preventive maintenanceand servicing□ Prepare site infrastructure for Truenatinstruments and testing□ Ensure a safe and functional testingsiteSuggested specifications of a solar panelas per the manufacturer:• Panel: 150 Watts. Dimensions (LxWxH):1490 x 665 x 35 mm• Battery: 12V 18Ah Lead Acid• Solar Charge Controller + DC to DCboost converter (12V to 170V, 100 Watts)Controller and converter available fromMolbio; panel, battery and installation tobe locally sourced. 193 Ice Lined RefrigeratorILR can maintain a temperature from +2°C to +8°C with as little as 8 hours of power supply in 24 hours 194 Audiometer Air conduction Audiometry (125-8000Hz) Bone conduction Audiometry 195 Bio Chemistry AnalyzerGeneral Information Machine TypeTest Speed Test Principle Test Method Calibration Type : Random access: Constant 200 tests/hour (Mono Reagent or Double Reagent): Colorimetric method, turbidimetry, Immuno turbidimetry: 1 Point End, 2 Point End, Fixed Time and Kinetics: Linear and Non Linear 1 Point Linear, 2 Point Linear, ExponentialLogi - 10g, 3P, 4P, Multi-point Linear, Spline, Line Graph Sample UnitReagent UnitReaction Unit Sample Tray Sample TubeSample Volume Sample ProbeSample Barcode Reagent TrayReagent VolumeReaction Tray Reaction Volume : 40 Sample Positions: Micro Cup & Test Tube & Blood Collection Tube (Ф 12 - 13) mm * (25 - 100) mm: 2 - 30µL, Step by 0.1 µL: Liquid surface detection, timely tracking for liquid volume Collision Protection: Sample barcode reader (Option): 40 Reagent Positions (40 for R1 or 40 for R2) 24 hours cooling system with paltier pad inside: 20 – 300 µL, Step by 1 µL: 44 reaction new pyrex cuvettes, perfect transmittance: 150µL - 330µL Mixing system Mixer : Paddle-type mixing, effective and reducing carryover Optical SystemOperating system Light Source Wave LengthAbsorbance Range ResolutionOperating System Report Printing Interface : Halogen Lamp: 340nm; 405nm; 450 nm; 505nm; 546nm; 578nm; 630nm; 700nm (4 more options): 0 – 4.0 Abs: 0.0001 Abs: Windows XP, Windows 7, Windows 8, Windows 10: 6 Formats Optional, Support Custom Formats: Pattern, TCP/IP network Interface Working Conditions Power Supply : AC 110/220V ± 10%, 50/60 Hz, 1000VAWater consumption : 8L/hour (maximum) Dimension Weight : 750mm * 550nm * 490mm (L*W*H): 70 kgs Power Supply 110/220V ± 10%, 50/60 Hz, 1000VA,Earthing voltage < 5V online ups (230V) with isolated transformer 2KVA 196 Blood Donor Couch Comfortable chair type with soft padding for cushioning and rexin cover.Seat, back rest and leg rest size designed for donor comfort.It should have step less electric remote controlled height adjustment approximately 58 – 60 cm.Adjustable arm rest for donor’s comfort and phlebotomist friendlyEasily tilted to head low position, electrically operatedComfortable working level for the operator. Lifting capacity - Approx 200 kg.4 Lockable castors for easy mobilityStorage Drawers for storing consummables & Blood Collection MonitorsUP/DOWN controlOPTIONS: 1.A paper roll holder can be fixed on the upper part of the chair. 2.Melodious musical Headphone can be integrated for patient relaxation while blood donation is in progress 197 BP Apparatus Digital 198 Cautery Machine SPECIFICATIONS FOR CAUTERY MACHINE(HIGH-END SURGICAL ELECTROCAUTERY WITH VESSEL SEALER)High-End Electro Surgical Unit with Vessel Sealer Unit should be comprised of:1. An integrated RF Electro Surgical Unit (For electrosurgical Cut & Coagulation modes for the optimum effectof HF surgery)2. Vessel Sealer (For sealing vessels & tissue structures, during open and laparoscopic surgeries).A) Electro Surgical Unit should be microprocessor controlled, US-FDA &/ European Certificate marked inaccordance with the medical devices directive (93/42/EEC) 4 Digit notified & Electro Surgical Unit shouldcomply with the requirement of the medical devices directive of class 1 equipment and electromagneticcompatibility.B) Electro Surgical Unit quoted should have a very strong Installation base- must be provided a minimum of 50installation base in India.C) Special bipolar mode for coagulation of vascular tissue (Vessel Sealing) up to 7 mm with Reusable/Disposable Hand Instrument for open as well laparoscopic surgeries & should have 510 K approval for 7 mmVessel.D) The system should have Monopolar Cut & Coagulation Mode, two Bipolar Modes with auto bipolar start &stop and Vessel fusion technology all integrated in one system. Should have around 8 Cutting Modes &around 8 Coagulation Modes.E) The equipment should be micro controller based & should adjust the power to get the desired surgical effecton the tissue. All settings should be controlled by the machine and according to the tissue deliver. Powershould be display on the screen with graph facility to show the deliver poweF) Should have Power and Voltage automatic regulation feature to prevent tissue damage and charring. Theoutput voltage should be regulated at various levels.G) The System should have LCD/ LED Backlight adjustment for good visibility in operating room, patient platemonitoring facility, audio-visual alarm, and deactivate output if contact between patient and patient plate isnot proper to eliminate the risk of patient burns.H) Should have optional facility of connecting reusable contact quality Monitoring Return Electrode Pediatric /Adult with 100% washable foot switches (for terminal cleaning & disinfection)- Monopolar & BiopolarI) The high End Electro Surgical Cautery Unit with Vessel fusion technology should be compatible with theintegration system of OR mainly O.E.M.’s like – Karl Storz, Olympus & De Vincy.J) The high-End Electro Surgical Cautery Unit with Vessel fusion technology should be supplied along withessential accessories from the same original equipment manufacturer, affidavit for the same has to besubmitted by the bidder, else bid will be rejected.1. Open and Laparoscopic Surgery Vessel seal instrument with cord. Reusable (which has certificate for theminimum shelf life of 50 applications and should be autoclavable- 01 each (Open & Lap) and ifDisposable 50 each (Open & Lap).2. Diathermy Pad/ Patients plate- adult/ pediatrics with patient plate cable if Reusable- 01 with a shelf lifeof minimum 50 applications and if disposable 50 pcs3. Monopolar two pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) withminimum shelf-life of 1000 applications or 24 months from date of supply-1no.4. Bipolar one pedal footswitch 100% Washable/ Water resistant (for terminal disinfection) with minimumshelf-life of 1000 applications or 24 months from date of supply-1no.5. Monopolar electrosurgical pencil with different electrodes either Reusable 01 Unit with reusable 05electrodes of various shapes with a shelf life of minimum 50 applications or Disposable- 50 Units6. Nonstick Bipolar forceps Straight & bayonet each with bipolar cord for forcep either Resuable 01 Unitwith a shelf life of minimum 50 applications or Disposable- 50 Units7. Reusable universal adaptor for attaching several Laparoscopic hand instruments with a shelf life of aminimum of 50 applications-1no.8. Cart with Castors with unconditional replacement if break within 05 years from the date. 199 Centrifuge 12 Tube 200 DVT Pump Deep Vein Thrombosis (DVT PUMP)• Size: 6.5” L x 7.0” W x 12.8” H• Weight: 2.5kg• Pressure Settings:• Calf/Thigh sleeve: 30, 40 (default), 50, 60 mmHg ; +10/-5mmHg Foot sleeve: 120 mmHg ; +10/-5mmHg• Input Rating: AC 100V-240V 50/60 Hz, 0.2A-0.55A• Fuse Rating: 1A, 250V• Appliance Class: Class I, Type BF• Not AP or AGP type• Classification to FDA: Class II• Classification to CDSCO: Class B• Humidity: Operation 30% to 75 %• Storage & Transportation 30% to 75%• Air pressure: 4 – 16 kPA• Temperature: Operation 15° - 35° C• Storage & Transportation 5-60 degree C• Cycle Time: Inflation 12 seconds +/- 10%• Deflation: 48 seconds +/- 10% 201 Prolene Suture Size 2-0 202 Prolene Suture Size 1-0 203 Prolene Suture Size 3-0 204 Nylone Suture 2-0 205 Disposable Hemorrhoidal Circular Stapler 32mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm 206 Disposable Hemorrhoidal Circular Stapler 34mm with Two Circular Staggered Staple-Lines ( 2 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Total 32 Staple Pins with Open Staple Leg Length of 3.5mm which can accommodates compressed tissue thickness from 0.75 to 1.5mm 207 Silk suture, USP 3-0, 70 cm, needle: 26*1*2 mm, reverse cutting, 3/8 circle. 208 Ethicon Ethilon Sutures USP 4-0, 3/8 Circle Reverse Cutting - NW3326 209 Nylone Suture 3.0 210 Botroclot Solution 211 Disp.LinearCutter 60 212 Disp.LinearCutter 80 213 Disp.LinearCutter 100 214 Disposable Curved Circular Stapler 29mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm 215 Disposable Curved Circular Stapler 31mm with Three Circular Staggered Staple-Lines ( 3 Rows ) and Optimized Staple Formation Technique, Tissue Compression Indicator, Open Staple Leg Length of 4.5mm which can accommodates compressed tissue thickness from 1.0- 2.5mm 216 Acetylsalicylic Acid (Aspirin)*(Tablet 25 mg),Tablet [202209005] 217 Allopurinol(100mg),Tablet [110034] 218 Artemether + Lumefantrine(20mg+120mg),Tablet [110149] 219 Bisacodyl(5 mg),Suppository [110294] 220 Boro-Spirit Ear Drops-(0.183 gm Boric Acid in 2.08 ml of Alcohol 10 ml vial),Drop [202209052] 221 Charcoal Activated (Powder)(100 gm box/pouch),Oral Powder [110051] 222 Ciprofloxacin Eye Ointment 0.3% ( 3gm Tube) [4460001] 223 Clofazimine(Tablet 50 mg 4),Tablet [202209022] 224 Cloxacillin(500mg),Capsule [120092] 225 Cloxacillin(Capsule 125 mg),Capsule [202209020] 226 Codeine(Oral Solution 15 mg/5 ml 60 ml bottle),solution [202209080] 227 Diethylcarbamazine(Oral Liquid 120 mg/5 ml 100 ml bottel),Liquid [202209023] 228 Diloxanide Furoate(Tablet 500 mg),Tablet [202209024] 229 Diphenylhydantoin(Tab 30 mg 10x10),Tablet [202209013] 230 Dispersable Tablet Hydroxyurea (100 mg 10x10),Tablet [202209073] 231 Finofibrate(Tablet 40 mg),Tablet [202209041] 232 Fluphenazine 1 ml Amp(25 mg / ml),Injection [120354] 233 Glycopyrolate(Inj 0.2 mg/ ml 1 ml vial),Injection [202209001] 234 Gum Paint (Tannic Acid)(2% w/v 15 ml bottle),Bottle [202209046] 235 Halothane BP 250ml [4000001] 236 Hepatitis B Immunoglobulin(100 IU/Vial),Vial [110319] 237 Human Chorionic Gonadotropin(Injection 10000 IU vial of 1 ml injection),Injection [202209062] 238 Human Chorionic Gonadotropin(Injection 5000 IU vial of 2 ml injection),Injection [202209063] 239 Hydroxyethyl(6% Saline solution for infusion)(Starch 6%IP 500 ml Bottel),Infusion [202209083] 240 Imipramine(25 mg),Tablet [110360] 241 Insulin soluble Inj. - 40 IU/ml [4350097] 242 Ipratropium Bromide inhaler 20mcg per puff(200 metered dose container),Inhaler [1100376] 243 Isoxsuprine(10mg),Tablet [120174] 244 IV Human Immunoglobin 5% IV IG((5mg/100ml Each),Injection 100ml injection),Injection [202209067] 245 Ketamine hydrochloride(10mg/ml (10ml vial)),Injection [110003] 246 Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 10 mg (B) CR),Tablet [202209033] 247 Levodopa (A) + Carbidopa (B)(Tablet 100 mg (A) + 25 mg (B) CR),Tablet [202209034] 248 Levodopa (A) + Carbidopa (B)(Tablet 250 mg (A) + 25 mg (B)),Tablet [202209035] 249 Levosalbutamol(50mcg/dose 30 capsule in 6 pack with 1 dispecing device),Capsule [202209070] 250 Levosulbutamol(100 mcg 30 capsule in 6 pack with 1 dispecing device),Capsule [202209069] 251 Lithium Carbonate(300 mg),Tablet [110358] 252 Lorazepam2 mg / ml1 ml Vial [110369] 253 Losartan(10 mg Tablet),Tablet [202209057] 254 Medroxyprogesterone acetate(Injection 150 mg 1 ML / VIAL),Injection [202209064] 255 Methyldopa Tab. - 250mg [4710040] 256 Morphine(Injection 15 mg/ml 1 ml ampule),Injection [202209081] 257 Noraderanaline Bitartrate(2 Mg Base/2ml (2ml Amp)),Injection [700472] 258 Normal Saline(Nasal Drops: Sodium Chloride Drops 0.05% w/v 10 ml vial),Drop [202209053] 259 Ormeloxifene(Tablet 30 mg 10x10),Tablet [202209065] 260 Phenobarbitone(200 mg/ml),Injection [110060] 261 Pilocarpine Eye drops 2%(5ml),Vial [110327] 262 POMALIDOMIDE(Cap 2 mg),Capsule [202209031] 263 Pralidoxime (PAM) Inj(25 mg/ml),Injection [4350085] 264 Premix Insulin(30:70 Injection (Regular: NPH)2 vial of 100 ml),Injection [202209066] 265 Promethazine(Injection 10 mg/ml 2ml vial),Injection [202209002] 266 Protamine(Injection 50 mg/5 ml 5 ml vial),Injection [202209044] 267 Pyridoxine Tab 10mg [4710380] 268 Sodium Aminosalicylate Granules(10 gm Bottel of 100 gm),Powder [202209028] 269 Sucralfate (20 mg Tablet 10 x 10),Tablet [202209058] 270 Surfactant Suspension(Inj 25 mg/ml),Injection [202209077] 271 Tab Mebeverine(Tab 200 mg 10 x 15),Tablet [202209056] 272 Tamoxifen tab.(10 mg),Tablet [4710305] 273 TOPOTECAN(Inj 4 mg 4 ml vial),Injection [202209032] 274 Verapamil(Injection 5 mg/2 ml 2 ml vial),Injection [202209045] 275 Alpha-Beta Arteether Inj 75 mg / 2 ml [700153] 276 Ampicilline 125mg/30ml Syrup [987655] 277 Antacid Chewable Tablet containing Aluminum hydroxide equivalent to dried gel 250mg+ Magnesium hydroxide 250mg+ Simethicone 50mg USP [4710419] 278 Benzyl benzoate emulsion( emulsion),Emulsion [4220001] 279 Calcium Syp 100ML Syrup (240mg/5 ml) [987642] 280 Cefpodoxime200 mg + Ofloxacine 200mg Tab.(200+200),Tablet [120980] 281 Cetrimide + Choline Salicylate Gel for oral ulcer 15ml Tube [4760001] 282 Cetrimide Cream BP(0.1% w/w),Tube [4760003] 283 Chloramphenicol 0.5%(5ml),Eye Drop [120073] 284 Tab Ciprofloxacin 250 + Tinidazole 500 mg 285 Tab Ciprofloxacin 500 + Tinidazole 600 mg 286 Chlorhexidine 0.2% Mouth Gargle(100 ml),solution [4630028] 287 Clobetasol 0.05% + Gentamicin 0.1% Cream 10 gm(10 gm tube),Cream [120082] 288 Cyproheptadine HCL + Tricholine Citrate(2mg + 275 mg / 5 ml (100ml Bottle)),Syrup [120098] 289 Dicyclomine Syrup [987647] 290 Digestive Drop ( Digestive Enzyme And Multivitamin with L Lysine )( 15 ml),Drop [987868] 291 Domperidone +Ranitidine 150mg Tab [987691] 292 Doxylamine Succinate + Pyridoxine(10mg+10mg),Tablet [120117] 293 Gentamicin Inj. - 40 Mg/Ml, 2ml AMP [987917] 294 Insulin Human Mixtard inj. - 30:70( ),Injection Solution for [4350096] 295 Ipratropium Bromide Powder for inhalation 250mcg/ml [4330004] 296 Ketoconazole Tab [4710123] 297 Lignocaine Hydrochloride Topical Solution USP(2%),Vial [4790014] 298 Magnesium Sulphate Powder(400gm),Powder [20201043] 299 Nepafenac ophthalmic(Suspension 0.1%),Eye Drop [140099] 300 Nepafenac(1mg/ml),Eye Drop [120685] 301 Nifedipine (Sublingual)(10 mg),Capsule [120548] 302 Oseltamivir H1 N1 Antiviral syp 75 mg [700120] 303 Paracetamol + Chlorphenaramine+ Phenylephrine(250 mg + 2.5 mg + 10 mg),Tablet [120560] 304 Paracetamol + Phenylephrine + Chlorpheniramine Maleate (125mg+2.5 mg+1mg) /ml(15 ml Bottle with Dropper),Drop [120561] 305 Paracetamol 100 mg/ml, 150 ml Drop(150 ml),Consumable [987903] 306 Paracetamol 75 mg/ml(10 ml Inj),Injection [987904] 307 paracetamol drop(100 mg/ml),Drop [4700041] 308 Pentoprozole 40mg +Domperidone 10mg Tab [987675] 309 Peptonised Iron 176.5 mg(Equivalent to 30 mg of Elemental Iron,Protein (as Peptone) 100 mg,Folic Acid 200 mcg, Vitamin B12 2.5 mcg 100ml),Bottle [20200910] 310 Piroxicam(ointment),Ointment [10000] 311 Prednisolone(10 mg/ml),Eye Drop [120259] 312 Roxithromycin 150mg Tablet [987689] 313 Sodium Chloride (Ophthalmic) 5%(10 ml),Eye Drop [120596] 314 Sodium Hyaluronate (Intraocular)(10 mg /ml 2ml),Injection [120597] 315 Syp. Cefodroxil 125mg/30mlSyrup [987657] 316 syrup cefpodoxime(50 mg),Syrup [700426] 317 Visco Gel for eye department 318 BSS Solution For Opthalmic Use 319 Lignocaine 4% heavy 320 Tetanus Toxide inj 5ml( ),Injection Solution for [4350104] 321 TetracyclineEye Ointment 1% 5 gm [120603] 322 Flurbiprofen Sodium 0.03%(5 ml),Eye Drop [120492]
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
Madhya Pradesh View Result →
47.
Educational and Research Institute #9250947 Technical Bid
Creation Of Manned Submersible Experience Centre At National Institute Of Ocean Technology, Niot Campus, Pallikaranai, Chennai , Pre Construction Works Dismantling Of All Paver Blocks Including Stacking Of Serviceable Material As Directed By The Engineer In Charge,And Disposal Of Unserviceable Materialsoutside Site Premises , Earthwork Excavation By Mechanical Means Using Jcb, Poclain,Etc., For Foundations, Footing, Rafts, Plinths, Pools, Under Ground Structures, Etc. In All Types Of Soil Including Dense, Wet Or Dry (Such As Yellow, Murrum, Hard Murrum/Gravel Or Mixture Of Any Kind), In Loose And Slushy Condition, Including Leveling, All Leads And Lifts, Rate To Include Stacking Within The Site Adjacent Plot Wherever Specified And Spreading In Layers To The Required Levels And Disposing The Excess Earth By Carting Away Out Side The Site To The Designated Areas Identified By The Local Authorities. Rate Is Inclusive Of Making Temporary Stepping/ Sloping, Shoring With Planking, Strutting, Sectioning, Trimming, Dressing Of Sides, Leveling Or Grading, Cleaning, Removing And Excavating Loose Pockets And Consolidating Them By Backfilling As Directed, Dewatering Of Surface Water Including Rain Water, Removal Of Slurry Generated While Excavation And Keeping The Area Free Of Water, Excavating Loose Pockets And Compacting The Same. Note: Authorised Working Space If Required Shall Be Considered As Per Is 1200. (Provision Of Slopes If Required For Execution).Excavation Upto 1.50M , Back Filling Available Excavated Earth To Excavated Areas In Layers Of 150Mm With Watering And Compaction. Rate Is Inclusive Of Making Temporary Stepping/ Sloping, Shoring With Planking, Strutting, Dressing Up Embankments: If Required, Bailing/ Pumping Out Of Water To Keep Site Dry While Back Filling; Costs Includes Conveyance Of All Materials, Labour, Machinery Etc. Complete Directed. Note: Authorised Working Space If Required Shall Be Considered As Per Is 1200. , Filling And Banking Approved With Good Quality Earth In Plinths, Basement, Areas Development Etc. Other Than The Back Filling Of Excavated Areas In Layers Not Exceeding 200Mm In Depth, Breaking Clods, Watering, Rolling Each Layer With Vibratory Compactor And At Inaccessible Places With Wooden/ Steel Rammers To Achieve 90 To 95% Proctor Density At Optimum Moisture Content; Dressing Up Embankments; If Required, Bailing/ Pumping Out Of Water To Keep Site Dry While Back Filling; Costs Includes Conveyance Of All Materials, Labour, Machinery Etc. Complete. Proctor Compaction Test To Done After Filling. , Supplying, Filling, Levelling, Watering And Consolidating With Approved Good Quality M-Sand In Layers Of Thickness 150Mm In Foundation & Flooring Of Any Depth Sides Of Foundation Etc., Including Loading, Transporting, Unloading , All Leads And Lifts, Labour, Ramming With Iron Or Wooden Rammers, The Surface Shall Be Flooded With Water For Minimum 24 Hours And Etc., All Complete As Directed. , Anti-Termite Treatment - Providingand Injecting Chemical Emulsion Chlorophyriphos 20 % Emulsifiable With Concentrates 1 % @ 5 Ltr. /Sqmof The Surface Or As Directed By Project Manager,For Pre-Constructional Anti -Termite Treatment And Creating A Continuous Chemical Barrier Under And Around The Column Pits, Wall Trenches, Basements Excavation, Top Surface Of Plinth Filling, Junction Of Wall And Floor Along The External Perimeter Of The Of The Building, Expansion Joints Over The Top Surface Of Consolidated Earth On Which Apron Is To Be Laid, Surroundings Of Pipes And Conduits Etc. Complete As Per Specifications. (Plinth Area Of Building At Ground Floor Only Shall Be Measured For Payment) , Piling Works Boringinallkindsofsoils(Asmetatsite)Gravelshingleetc. Includingwaterbearingstrata,Disposalofearthetc.Takenout Fromboresoutsidethesiteorasdirectedbysiteincharge, Excludingthecostofsteel Reinforcement Butincludingthecostofbentonitesolutionfor Bore Stabilisation Etc. By Using Pumps ( Capacity Minimum35 - 40 Hp) Prior To Placing Concrete, Disposal Of Bentnite Solution Etc As Directed All Complete (Length Of The Pile Shall Be Considered For Payment).Therateshallincludecostofalignmentoftwonos.Ofbarof Required Diameter Which Is To Be Used To Hold The Reinforcement Cage Vertical During Concreting, Making Slurry Vats At Pre Approvedlocationofsite,Usingbentonite,Removal&Shiftingof Bentonite Slurry, Solid, Semisolid Liquid Muck From Vat/Drain, Dry/Wet Soil Mixed With Bentonite And The Surplus Earth Excavated Fromvattooutsideofthesitepremisesbytanker&Other Transport. Piles Shall Be Cast As Per The Schedule Of Cut Off - Level Given In The Execution Drawing.Pile Driving 450 Mm Dia, 18 M Long. , Providing Andinstallingcastinsitureinforcedcementconcrete Pile Of Specified Dia Meter And Length Below The Pile Cap,In M-35 Cement Concrete - Ready Mixed Concrete, Design Mix With Minimumcement400kg/Cum(Useofflyashprohibited) Including Admixture As Approved By Engineer-In-Charge To Carry A Safeworkingloadnotlessthan40t. , R.Cc/P.C.C Works Providing And Laying Required Thickness Of Controlled Plain Cement Concrete Of Pcc 1:4:8 Grade Using Over 20Mm And Down Size Coarse Graded Hard Stone Aggregate For Levelling Course In Pile Cap And Flooring At Any Mass Concrete And Other Similar Works At All Levels And Heights, Elevations, Mechanical Mixing, Transporting And Placing At All Lifts, Ramming With Iron Rammer, Compacting, Levelling, Curing For 7 Days, Shuttering, Dewatering Wherever Necessary, The Cost Of All Materials, Labour, Leads And Lifts, Tools And Plant, Machineries Etc., Complete As Per Specification. (100Mm Thick) (I) Pcc 1:4:8 , (Ii) Pcc 1:2:4 , Providing And Laying Cast-In-Situ Controlled Reinforced Cement Concrete Of The Following Grades Using 20Mm And Down Size Coarse Graded Machine Crushed Hard Stone Aggregate Including Designing The Mix, Weigh Batching, Mechanical Mixing, Transporting And Placing At All Lifts, Vibrating, Consolidating, Curing And Finishing Smooth As Required All Exposed Faces, Complete For The Following Rc Structural And Other Elements Including Formwork Either Straight, Curved, Plain, Tapered Or Sloped, Supplying And Mixing Admixtures, Dewatering Wherever Necessary, The Cost Of All Complete Materials Labour, All Leads And Lifts, Tools, Plant And Machineries, Hire And Fuel Charges And All Other Incidential Charges Etc., All As Per Specifications, Drawings And As Directed, But Excluding Steel Reinforcement, Irc Mesh, Insert Plates Which Will Be Paid For Separately Under Relevant Items. The Rates Quoted Shall Hold Good For All Foundations At Any Depth, Flooring, All Floors, Heights, Levels, Elevation, Below Ground Level, Basement, Trenches, Pits And Etc Complete. Grade: M35. (I) Pile Cap 750Mm Thk , (Ii) Plinth Beams 230 X 450 , (Iii) Grade Slab 175Mm Thk , (Iv) Floor Deck Slab - 75Mm Thk , (V) Pedestal , Providing And Supplying Of Reinforcement Inclusive Oflabour Charges For Cutting, Straitening, Fabricating And Fixing In Position Ms Bars Conforming To Is-432 / High Yield Strength Deformed Bars (Tor Steel) Conforming To Is-1786 Of Fe 415 Grade / For Pro Steel Confirming To Is-1786 Of Fe550 Of All Dia For Reinforcement In All Rcc In Situ Works Including Flooring And Precast Works At All Levels And Heights Above Finished Floor Level For Plinth Beam, Columns, Roof Beam, Roof Slab, Lintel, Sunshade, Loft, Drops, Sill Level Slab And Etc., And For Foundations, Trenches, Pits, Lift Pits Etc., Below Finished Floor Level Including Cost Of Straightening, Cutting, Bending To Shape Fabricating And Tying With 18 Guage Gi Binding Wire, Providing And Fixing Cement Cover Blocks, Dewatering Wherever Necessary Etc., All Complete As Per Drawings And Specifications And As Directed By The Engineer. The Rate To Include Cost Of Steel,Binding Wire, Cement Cover Blocks, All Cuts And Wastes Which Will Not Be Measured. Only Laid Weight Will Be Measured Including Authorised Laps. Cuts And Wastes Will Not Be Measured For Payment. Reinforcement , Approved Plywood Or Steel Plate Shuttering & Centering For Structural Concrete Work In Locations Called For Including Strutting, Propping, Bracing, Bolting, Wedging, Casing, Striking, Removal, Etc. Complete For Any Size, Section, Or Thickness. Props Shall Consist Of Well-Designed Steel Pipes Adequately Braced( Wooden Ballis As Props Shall Not Be Permitted). The Item To Include Centering & Shuttering At All Heights And Levels. Allow For Forming Grooves, Drip Courses, Chamfers, Cut-Outs, Openings, Etc. Were Called For And For Dressing With Approved Shuttering Oil To Prevent Adhesion. Unexposed Concrete Surfaces, Subsequently Left Untreated (In The Condition Obtained On The Removal Of Formwork) Shall Not Constitute Exposed Concrete Work And Shall Be Measured Under This Item Only. Irregular Shapes With Sides That May Not Be Perpendicular To Each Other Or Shapes Not Confirming Rectangular Or Square Shall Not Be Paid Separately. (Quoted Rate To Include All Staging Up To Any Height) (I) Pile Cap 750Mm Thk , (Ii) Plinth Beams 230 X 450 , (Iii) Grade Slab 175Mm Thk , (Iv) Floor Deck Slab - 75Mm Thk , (V) Pedestal , R.C.C/P.C.C Works Providing And Layingbrick Work Using Bricks Of Class Designation75in Foundations And Upto Plinthlevel In Cementmortar1:6( 1 Cement :6 Coarse Sand ) Including,Joints Finished Flush/Raked To 12 Mm Depth, Etc. Complete As Directed By The Engineer In Charge, (Cleaning Andsoaking The Bricks At Leastfor 24 Hours Before Use , Curing Etc. All Complete At All Heights / Depth). Rate To Include Plastering, Waterpoofing As Per Architect. , Fabrication Works Providing, Fabricating,Transporting, Assembling & Erection In Position Of Steel Members For Steel Columns,Built Up Beams Using Structural Tubular Sections (Round, Square Or Rectangular Hollow Tubes Etc. Confirming To Is 4923 / Is 1161, Yield Strength 310 Mpa As Per Latest Is Code) To The Required Profile & Shape As Called For As Per The Drawing & Specifications. This Item Also Includes The Shear Connectors /Studs & Fusion Weld To Top Of Horizontal Member. This Item Also Includes Preparation Of Shop Drawings & Their Approval, Necessary Templates, Adequate Temporary Supports, Scaffolding & Staging, All Cutting, Grinding, Sliding & All Labour, Tools, Plants& Equipments & Operations Etc. Required To Complete The Job As Per Drawing & Specification. Every Precaution To Be Taken To Prevent Rusting Of Sections. This Item Also Includes All Test On Materials & Welded Fabricated Parts As Per Specification & Direction Of Engineer - In - Charge. Temporary Bolts & Nuts (Grade En 8) To Be Used During Assembling & Shall Be Removed Before Site Erection. All Site Erection Bolts Shall Be Hsfg Type Only. The Item To Include Cost Of Sand Blasting On Materials, Application Of Primer & Various Coats Of Internal & External Painting In Fabrication Shop &Final Painting On Site Including All Touch Up Works After Erection As Per Technical Specification. (I)The Scope Of Work For This Item Includes : A) Design & Fabrication Of Any Additional Temporary Structure Including All Type Of Lifting Brackets, Supporting Brackets, Which Will Be Required For Transportation & Erection In Position / Launching Of Fabrication Part Or Completeelement In Position.B) Making Provision & Arrangement For Required Opening / Inserts For Fixing Lights Fixtures & Funning Cable Conduits . C) All Incidentals .Labour, Equipment & Plants Required To Execute & Complete The Job From Fabrication To Erection At Final Position As Per Drawing, Specification & Direction Of Engineer - In -Charge. D) Cleaning & Removing Of All Spoil, Temporary Arrangement For Casting Of Deck Slab.E) All Safety Measures Required To Execute & Complete The Work.F) Procurement Of All Materials From Approved Manufactures & Fabrication. Complete Methodology For Structural Steel Work . Name Of Workshop For Fabrication Works. Testing Facilities & Erection Procedures Etc.To Be Intimated For Approval Of Engineer - In - Charge. G) The Provision Of Temporary Bearing / Sand Jacks For Supporting Steel Members During Erection. H) Provision Of Stability Duringerection Against Wind Load Or Any Other Type Of Loading On Structural Steel Members During Erection. , (Ii) Measurement Shall Be Only For Structural Steel Which Is Erected & Is Part Of Permanent Structure & Paid As Per Approved Shop Drawings. All Wastages,Temporary Works,Jigs, Temporary Assembly Bolts Etc. Are Deemed To Be Included In Quoted Rates . No Allowance Or Increase In Weight For Welding,Nuts & Bolts Etc Will Be Applicable. , Providing And Fixing Bare Galvalume Sheets Of 0.475 Mm Thk With Self Drilling Screws, Ridge Cap And Rainwater Downtake Pipes Including Fixing Skylight Panels With Butyle Sealant Beads. Brand: Jsw. , Flooring & Cladding False Flooring: The System Should Be Of Nominal 600Mm X 600Mm (35Mm Thick) Modular Panels With Heavy-Duty Pedestals. The Total System Weight Shall Not Exceed 40 Kg/Sq.M. The System Shall Be Able To Withstand A Udl Of 2000 Kg/M2 (1117Kg/Sq.Mt) And A Point Load Of 450 Kg/In2 .Panels Shall Be Made Of Steel With An Infill Of Lightweight, Non-Combustible Having Fireresistance, Thermal Insulation, And Flame Resistance Properties At 60 Min Cementitious Material.The Bottom Of The Panel Shall Be Embossed In Hemispherical Shape To Give Strength And Flexural Rigidity.The Infill Material Shall Not Become Loose When The Panels Are Cut. Panel Should Be Able Towithstand An Ultimate Load Of At Least 2.5 (3.00) Times The Designed Point Load.The Entire Panel Shall Be Coated With Epoxy Powder Coating Of 75-100 Microns On The Exposed Surface.The Panel Top & Bottom Sheet Shall Be 0.9/0.7Mm (0.7/0.6Mm) Resp. Flatness Should Be 0.2Mm.The Panels Shall Have A Top Covering Of Anti-Static High Pressure Laminate With Resistance Of 2X105 –5X108 Ohms. The Hpl Thickness Shall Not Be Less Than 1.5Mm.(1.6Mm).Pedestal Base Shall Be Square Of 100Mm X 100Mm X 2Mm Bearing Area And Assemble To A Tube Of 22Mm Dia With 2Mm Wall Thickness. The Pedestal Head Should Not Be Less Than 3Mm Thick.The Pedestals Should Be Able To Accept An Axial Load Of 22,500N And An Ultimate Load Not Lessthan 45,000N. Pedestal Head Shall Be Galvanized Die-Cut Steel Welded To A Counter Locking Leveling Nut.The Pedestal Head Shall Be Provided With Pvc Cap For Acoustic Dampening. Height Of Pedestal Shall Be Approximate 300 Mm For Floor /150Mm For Steps. , Providing And Fixing Aluminium Composite Panel Of Eurobond/Aludecor Make, Cladding In Combination Of Metallic / Solid Colours, Including All Necessary Frames Work And All Complete. Panel Should Consist Core Of Anti-Toxic Low Density Polyethylene (Ldpe) 3.5Mm Sandwiched Between 2 Skins Of Thick Aluminium Coil Of 0.25Mm. The System Shall Be Installedusing50mm X 50Mm X 50Mm Long 3Mm Thickness G.I L Brackets / 75Mmx50mmx50mm Long 3Mmthicknessg.I.L Brackets @ Min 1.5 Metre Interval Vertically Fastened By 8Mm Dia X 75Mm Long Double Ring/Single Ring Wedge Anchors And 6Mm X 60Mmlong Rawal P/T Type Anchor Fastener Of Uip Brand(Germany Make). 38Mm X 38Mm Thick And 38Mm X25mm L-Angle And 50Mm X 25Mm Box Section Will Be Used For Mullions And Transom With Necessary Accessories, Such As Screws, Rivets, Bolts, Nuts And Washers Shall Be In Zinc Coated/Galvanized Steel.The Bracket Support Shall Be Designed As Per Manufacturers Specification. Sealing Shall Be Done, Using Weather Sealant Of Dowsil Or Equivalent. , Providing And Fixing Corrugated Sheet Cladding In Exterior Elevation In Area / Color As Specified By The Architect To Be Done With Required Channels As Per Manufacterers Specifications. , Providing Andfixing Of 12Mm Thick Bison Board False Ceiling: Metal Framed Suspended Ceiling (Seamless Finish) - Single Layer.False Ceiling Erection To Be With Required Perimeter Channels, Intemediates & Cross Channels As Per Manufacterers Specifications. 6 X 4 Bison Board Fixed With 25Mm Long Self Drilling Screwws With Philips Head. Surface To Be Finished With Jointing Compound And Fibre Taped , Ready To Take Paint Finish.Fixing Channel Size: , Providing Andfixing Of 12Mm Thick Bison Board Partition Walls: To Be Done With Required Channels As Per Manufacterers Specifications On Both Sides Of The Walls/ Partitions. Fixing Channel Size: 65 X 30 Mm / As Per Vendor. , Providing Andfixing Of 9Mm Thick Laminate Cladding On Interior Walls: To Be Done With Required Channels As Per Manufacterers Specifications On Both Sides Of The Walls/ Partitions. 1350 X 295 Panel , Brand : Vox , Providing Andfixing Of Parametric Mdf Panel With Laminate Finish-Fire Rated To Be Done With Required Channels As Per Manufacterers Specifications On Specified Walls/ Partitions, Panel Size 8 X 4 , Base Board 25Mm= 1 Sheet & Parametric Panel 11Mm (Vertical)= 45 Strip, Brand: Glopanel, Fixing Channel Size: 65 X 30 Mm / As Per Vendor. , Providing And Laying Groundcover - Pebbles - Size 50-75Mm Below Staircase. , Providing And Laying Carpet Flooring Over False Flooring, Color And Pattern As Specified By The Architect. , Providing Andfixing Of Vinyl Printed Display Boards On Interior Walls: To Be Done With Required Channels As Per Manufacterers Specifications On Both Sides Of The Walls/ Partitions. , Providing And Laying Machine Cut, Leather Polished Granite Slab Flooring Of Approved Sample, 18Mm Thick And Size As Per Drawings, In Approved Pattern, As Per The Drawings Provided By The Architect, By Applying Mortar To The Substrate With The Flat Side Of The Trowel, Pressing Firmly To Work It Into The Surface; Combing On Additional Mortar With The Notched Side Ue The Proper Sized Notched Trowel For The Stone To Ensure Full Bedding Of The Stone On Checkered Plate Etc. Complete. , Door / Window / Glass Work Providing And Fixing Steel Door Of Size As Mentioned Below With Tata Pravesh Brand -Constructed From 0.0008M Swg Gi Sheet. 0.046M Thk, Frame Of 0.1 X 0.058 Galvanized Iron Profile Dimension, Powder Coated, Ss Ball Bearing Butt Hinges, Mortise Sash Lock With Handles,Mortise Dead Bolt,Latch, Panic Device Provided. -Main Door / Server Room Door , Fire Rated Door Providing And Fixing Steel Door Of Size As Mentioned Below With Tata Pravesh Brand -Constructed From 0.0012M Swg Gi Sheet. 0.046M Thk, Frame Of 0.1 X 0.058 Galvanized Iron Profile Dimension, Powder Coated, Ss Ball Bearing Butt Hinges, Mortise Sash Lock With Handles,Mortise Dead Bolt,Latch, Panic Device Provided. -Service Door , Providing And Fixing Of Toughened Glass Floor Over The Digital Diaply Flooring Using Ms Structure (80Mm X 80Mm X 4Mm Thick As Outer Section And 80Mm X 40Mm X 4Mm Thick As Inner Section) And Glass (8Mm St 167 Toughened Glass + 1.52Mm Clear Pvb + 8Mm St 167 Toughened Glass) Using Spacer Tape With All Other Necessary Accessories. And Need To Arrest 8Mm Fiber Cement Panel With Painting. The Cost Including Of Glass Loading, Fixing And Transport Charges. , Providing And Fixing Anodized/Powder Coated Aluminum Worksliding Doors With Extruded Built Up Standard Tubular And Other Sections Of Approved Made Confirming To Is 733 And Is 1285, Anodic Or Transparent Or Dyed To Required Shade According To Is:1868 (Minimum Anodic Coating Of Grade Ac 15), Fixed With Rawl Plugs And Screws, Or With Fixing Clips, Or With Expansion Hold Fasteners Including Necessary Filling Up The Gaps At Junctions, Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitered And Jointed Mechanically, Wherever Required Including Cleat Angle, All Necessary Hardware Fittings All Complete As Per Architectural Drawings And As Directed The Glass Should Be 5/6Mm Thick Toughened Glass Of Modi/ Saint Gobain Or Equivalent.Ss Mosquito Mesh Mesh Gap: 1.3Mm Opening Aperture, Wire Dia: 30 Swg Material As Per Ss: 2245 Material Grade: Aisi 304. The Cost Includes All Material Machinery Andlabour Including Scaffolding And Any Other Preparatory Work To Install And Complete And Clean As Directed By Engineer In Charge , Miscellaneous Providing And Fixing Of Glass Canopy Using Ms Structure (80Mm X 80Mm X 4Mm Thick As Outer Section And 80Mm X 40Mm X 4Mm Thick As Inner Section) And Glass (8Mm St 167 Toughened Glass + 1.52Mm Clear Pvb + 8Mm St 167 Toughened Glass) Using Spacer Tape With All Other Necessary Accessories. And Need To Arrest 8Mm Fiber Cement Panel With Painting. The Cost Including Of Glass Loading, Fixing And Transport Charges. - Over Main & Service Doors , Monkey Ladder Height: 3.5M / Width: 0.6M , Invisible Grill: 3Mm Dia : @250Mm C/C- Staircase And Parapet , Sub Head B - Electrical Works Part-A Wiring Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Of 25Mm Pvc Conduits, Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , (Xii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 12M Length) , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Ofmetal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (The Item Excluding Cost Of 19Mm/25Mm Dia Pvci.E, Point Wiring In The Existing Conduits) (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , (Xii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 12M Length) , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Of 25Mm Frls Conduits, Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Point Wiring With Modular Type Switches, Sockets And All Materials As Per The Point Wiring Chart. The Item Including Cost Of Supply And Installation Of 25Mm Ms Conduits, Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Switches, Sockets, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), 3 Run Of 1.5Sq.Mm Frls Copper Wires, Bakelite Connectors, Crimping Type Ferrules, Copper Lugs, Brass Cup Washers & Brass Screws, Clamps & Screws And Bolt & Nuts Etc. All The Points Shall Be Terminated With 300Mm Length Of Additional Wires Along With Connector Terminal Blocks. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 4M) , (Ii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 6M) , (Iii) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 9M) , (Iv) One Light / Exhaust Fan / Wall Mounting Fan Point Controlled By One No. 1-Way 6 Amps Switch. (Upto 12M) , (V) Six Light Points Controlled By One No. Mcb (Upto 12M) , (Vi) Seven Light Points Controlled By One No. Mcb (Upto 12M) , (Vii) One Light / Exhaust Fan / Wall Mounting Point Controlled By Two Nos. 2-Way 6 Amps Switch. (Upto 12M) , (Viii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 3M Length) , (Ix) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 4M Length) , (X) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 6M Length) , (Xi) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 9M Length) , (Xii) One Additional Light Point Extended From The Existing Light Point And Controlled By Existing Switch. (All Items Are As Similar To {A1.A} But Excluding Of Switch Boxes, Switches And Sockets) (Upto 12M Length) , Power Receptacles Supply, Installation, Testing And Commissioning Of Power Points By Providing Following Switches/Sockets, Mounted Flush To The Walls Usingms Boxes, Inner Plates, Front Plate, Modular Switches And Sockets With All Wiring Accessories. (I) One 6A Dependent 5-Pin Socket Point Controlled By One No Of 6A Switch. (Switch & Socket Are Mounted In A Dependent Switch Box) , (Ii) One 6A Independent 5-Pin Socket Point Controlled By One No Of 6A Switch. (Switch & Socket Are Mounted In An Independent Switch Box White Colour) , (Iii) One 6A Independent 5-Pin Socket Point Controlled By One No Of 6A Switch. (Switch & Socket Are Mounted In An Independent Switch Box Black Colour) , (Iv) One 6A One Way Independent 5-Pin Socket With Terminations , (V) One 6A One Way Dependent/Independent Switch With Terminations , (Vi) One 6A/16A 5-Pin Socket Point Controlled By One 16A Switch With Indicator. (Switch & Socket Are Mounted In An Independent Switch Box) , (Vii) Two Nos 6A/16A 5-Pin Socket Point Controlled By Two Nos 16A Switch With Indicator. (Switch & Socket Are Mounted In An Independent Switch Box White Colour) , (Viii) Two Nos 6A/16A 5-Pin Socket Point Controlled By Two Nos 16A Switch With Indicator. (Switch & Socket Are Mounted In An Independent Switch Box Black Colour) , (Ix) Two Nos Of 6A Independent 5-Pin Socket Points Controlled By Two Nos Of 6A Switches. (White Colour) , Supply, Installation, Testing And Commissioning Of Power Points By Providing Following Switches/Sockets, Mounted Flush To The Walls Usingms Boxes, Inner Plates, Front Plate, Modular Switches And Sockets With All Wiring Accessories. (I) 2 Module , (Ii) 3 Module , (Iii) 4 Module , (Iv) 6 Module , (V) 8 Module , (Vi) 12 Module , (Vii) 16 Module , Supply, Installation, Testing And Commissioning Of Surface/Concealed Type Of Main Circuit Wiring From Panel/Db To Dbs, Db To Switch Boxes And Switch Box To Other Switch Boxes Using 1100V Grade Pvc Insulated Multistranded Frls Copper Wires, To Be Drawn Through Existing Laid Conduits. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (The Item Excluding Cost Of 25Mm Dia Frls Pvc/Ms Conduit-Circuit Wiring In The Existing Conduits) (I) 3 Runs Of 1.5 Sq.Mm. Frls Copper Wiring In The Existing Laid Frls Pvc/Ms Conduits. (This Item Will Be Considered Only Where The Point Wiring Exceeds The Mentioned Length) , (Ii) 2 Runs Of 2.5 Sq.Mm. & 1 Run Of 1.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Iii) 2 Runs Of 4 Sq.Mm. & 1 Run Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Iv) 2 Runs Of 6 Sq.Mm. & 1 Run Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (V) 4 Runs Of 4 Sq.Mm. & 2 Runs Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Vi) 4 Runs Of 6 Sq.Mm. & 2 Runs Of 2.5 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , (Vii) 4 Runs Of 10 Sq.Mm. & 2 Runs Of 4 Sq.Mm. Frls Copper Wiringin The Existing Laid Frls Pvc/Ms Conduits. , Supply And Installlation Of Surface/Recessed Type Frls Pvc, Rigid/Flexible, Conduits Of The Following Sizes With Required Couplers, Junction Boxes, Bends, Ceiling/Wall Plates, Metal Boxes, Draw Boxes & Top Cover Plate (3Mm Hylam Sheet), Clamps, Screws, Bolt & Nuts And Necessary Fixing Accessories Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 20Mm Dia 2Mm Thick Rigid Pvc Conduits. , (Ii) 25Mm Dia 2Mm Thick Rigid Pvc Conduits. , (Iii) 20Mm Dia 1.6Mm Thick Rigid Pvc Conduits. , (Iv) 25Mm Dia 1.6Mm Thick Rigid Pvc Conduits. , (V) 20Mm Dia 2Mm Thick Rigid Frls Pvc Conduits. , (Vi) 25Mm Dia 2Mm Thick Rigid Frls Pvc Conduits. , (Vii) 20Mm Dia 1.6Mm Thick Rigid Frls Pvc Conduits. , (Viii) 25Mm Dia 1.6Mm Thick Rigid Frls Pvc Conduits. , (Ix) 20Mm Dia 1.6Mm Thick Rigid Ms Conduits. , (X) 25Mm Dia 1.6Mm Thick Rigid Ms Conduits. , Part-B- Distribution Board Supply, Installation, Testing And Commissioning Of Following Ways Of Surface/Flush Mounting, Double Door Phase Segregation Seven Segment Type Tpn Mcb Dbs Of Sheet Steel, Powder Coated, Ip42 Protection, Metal Door And Cable End Box Etc. The Item Including Terminal Connectors For All Incoming And Outgoing Circuits, Duly Pre-Wired With Suitable Size Of Frls Pvc Copper Wires Upto Terminal Blocks, Tinned Copper Bus Bar Of Suitable Rating, Neutral Links, Earth Bars, Detachable Gland Plate, Interconnections By Using Crimping Type Ferrules & Copper Lugs, And Engraving Of Laminated As-Built Circuit Drawings In The Door Inside Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 4Way , (Ii) 6Way , Supply, Installation, Testing And Commissioning Of Following Ways Of Surface/Flush Mounting, Vtpn Mcb Dbs Of Sheet Steel, Powder Coated, Ip43 Protection, Metal Door And Cable End Box Etc. The Item Including Terminal Connectors For All Incoming And Outgoing Circuits, Duly Pre-Wired With Suitable Size Of Frls Pvc Copper Wires Upto Terminal Blocks, Tinned Copper Bus Bar Of Suitable Rating, Neutral Links, Earth Bars, Detachable Gland Plate, Interconnections By Using Crimping Type Ferrules & Copper Lugs, And Engraving Of Laminated As-Built Circuit Drawings In The Door Inside Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: 12 Way , Supply, Installation, Testing And Commissioning Of Following Ways Of Surface/Flush Mounting, Spn Mcb Dbs Of Sheet Steel, Powder Coated, Ip43 Protection, Metal Door And Cable End Box Etc. The Item Including Terminal Connectors For All Incoming And Outgoing Circuits, Duly Pre-Wired With Suitable Size Of Frls Pvc Copper Wires Upto Terminal Blocks, Tinned Copper Bus Bar Of Suitable Rating, Neutral Links, Earth Bars, Detachable Gland Plate, Interconnections By Using Crimping Type Ferrules & Copper Lugs, And Engraving Of Laminated As-Built Circuit Drawings In The Door Inside Etc. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 8Way , (Ii) 12Way , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Single Phase / Three Phase C Curve, 10Ka Mcbs To Be Fixed In The Existing Mccb/Mcb Dbs Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 6A To 32A Single Pole Mcb , (Ii) 40A To 63A Singl Pole Mcb , (Iii) 6A To 32A Singl Pole Neutral / Double Pole Mcb , (Iv) 40A To 63A Singl Pole Neutral / Double Pole Mcb , (V) 6A To 32A Triple Pole Mcb , (Vi) 40A To 63A Triple Pole Mcb , (Vii) 6A To 32A Four Pole Mcb , (Viii) 40A To 63A Four Pole Mcb , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Three Phase 18Ka Adjustable Thermal Magnetic Release Type Mccbs To Be Fixed In The Existing Mccb Dbs Or Panels Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer:100A Four Pole Mccb , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Single Phase / Three Phase Rccbs To Be Fixed In The Existing Mccb/Mcb Dbs Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 25A Double Pole Rccb, 30Ma , (Ii) 63A Four Pole Rccb, 30Ma , (Iii) 40A Four Pole Rccbo, 30Ma , (Iv) 32A Four Pole Rccbo, 300Ma , (V) 63A Four Pole Rccb, 300Ma , Supply And Installation Of Blanking Plates In The Existing Mccb/Mcb Dbs Or Enclosures Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: , Supply, Installation, Testing And Commissioning Of Following Ratings & Poles Of Single Phase / Three Phase Rccbs To Be Fixed In The Existing Mccb/Mcb Dbs Or Enclosures Complete With Interconnections By Using Crimping Type Ferrules And Copper Lugs Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) Double Pole Enclosure For Mcbs , (Ii) Four Pole Enclosure For Mcbs , Supply, Installation, Testing And Commissioning Of Following Weather Proof Boxsuitable For Independent Mounting Of Mcb/Mccb/Rccbs Complete With All Necessary Fixing Accessories Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) Double Pole Enclosure For Mcbs , (Ii) Four Pole Enclosure For Mcbs , Supply, Installation, Testing And Commissioning Of Following Weather Proof Boxsuitable For Independent Mounting Of Mcb/Mccb/Rccbs Complete With All Necessary Fixing Accessories Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer: (I) 100 X 100 X 50 Mm , (Ii) 150 X 150 X 50 Mm , (Iii) 300 X 300 X 50 Mm , Part-C Luminaires And Fixtures Installing, Testing And Commissioning Of The Following Luminairesincluding Driver, Connecting Wire,Clamps, Screws, Bolt & Nuts, Down Rods, Required Connector Block Terminals And Necessary Fixing Accessories Etc. (I) 230V, 18W Led Spot Light Luminarie. , (Ii) 230V, 15W Led Down Light Luminaire , (Iii) 230V, 15W Led 8 Profile Light Luminaire , (Iv) 230V,15-20W/Meter Led Strip Light Fittings. , Installing, Testing And Commissioning Of Wall Mounted Fan , With Mounting Frame, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Part-D Lt Panels Supply,Installation, Testing And Commissioning Of 415V Cubical Type, Fully Compartmenalised, Floor Mounted Type Lt Switch Boards Fabricated With 14G Crca Sheet, Powder Coated With Siemens Grey (Ral 7032) After Seven Tank Process And Complete With Welded & Bolted Design And All Incoming & Outgoing Switch Gears As Per The Following.Suitable Aluminuim Busbars, Control Wiring, Control Fuses, Seperate Metering Compartment (Incoming) With Multi Function Meter, Phase Indications With Necessary Control Wiring. Safety Features And Items Including Necessary Earthing Throughout The Bottom Length, 6 Sq.Mm Frls Copper Wire Interconnections For Compartment Earthing, Complete Copper Control Wiring With Crimping Type Ferrules, Copper Lugs, Proper Engravation On Each Compartment Etc.The Switch Boards Shall Be Cpri Approved Of Factory Assembled And Tested. All The Mccbs With Micro Processor/Thermal Magnetic Releases And Have Rotary Handle Mechanism & Spreader Current Density Not More Than 0.7A/Sq.Mm For Aluminium Bus Bar. Neutral Current Rating Is Half The Phase Currentall Busbars Shall Be Fixed With Standard Space Clearance And With Colour Coated Heat Shrinkable Pvc Sleeves With Dmc/Smc Bus Bar Supports And Suitable Earth Bus (25 X 3Mm Cu).The Cable Entry Shall Be From The Bottom/Top As Per Site Requirement.The Item Including Cost Of Ms Base Frame Of 75Mm Height, 3.15Mm Sheet Steel Or 40X40x6mm Ms Angle For Load Bearing Members, Lifting Hooks, Steel Support Structure Required For Erection And Its Painting, Minor Civil Works, Vendor Drawings, Necessary Safety Clearance From Statutory Authorities, Panel Approval From Tneb Till Obtaining Final Power Supply, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer.The Contractor Shall Submit General Arrangement & Control Wiring Drawings And Get Approval From Site Engineer/Consultant Before Commence The Fabrication Works. Sub Panelincomer: (I) 100A 4P On-Load Auto Change Over Switch With Control Mcbs, With Rotary Handle Mechanism & Spreader And Phase Indications Etc. - 1 No. (Ii) 100A, Tpn, 25Ka, Mccb With Adjustable Thermal Magnetic Releases And Rotary Handle Mechanism & Spreader- 1 No , Metering:(I)3 Nos-Ct Ratio 100/5A,Cl:1.0 Tape Insulated Type With Suitable Sorting Links..(Ii) 3 Nos-Ct Ratio 100/5A,Cl:1.0, 15Va Tape Insulated Type With Suitable Sorting Links Power Factor Sensingrelay1 Set – Indication Lamps For R,Y,B, Breaker On(Red), Breaker Off (Green), Breaker Trip (Amber) With Control Mcbs.Bus Bar:100A, Tpn, 25Ka, For 1 Sec Aluminium Bus Bar (I)Phase: Current Density Not More Than .7A/Sq.Mm(Ii)Neutral: Half Of The Phase Current (0.5 X Phase) (Iii) Earth: 25X3mm Copper Flatoutgoing:(I)63A Fp 10Ka Mcb C Curve- 3 Nos(Ii) 40A Fp 10Ka Mcb C Curve- 1 No(Iii)32A Fp 10Ka Mcb C Curve- 3 Nos (Iv) 16-32A Dp 10Ka Mcb C Curve- 1 Nonote:All Outgoing Feeders Should Be Provided In Individual Compartment , Supply, Installation, Testing And Commissioning Of 415V Cubical Type, Non Compartmenalised, Floor/Wall Mounted Type Automatic Power Factor Correction Panel Board Fabricated With 14G Crca Sheet, Powder Coated After Seven Tank Process And Complete With Bolted Design And The Provisions As Follows. Gas Filled Cylindricalheavy Duty Capacitors (App Type) Of 10Kvar . The Switch Boards Shall Be Cpri Approved Of Factory Assembled And Tested.The Cable Entry Shall Be From The Bottom/Top, Suitable Aluminuim Busbars, Control Wiring, Control Fuses, Seperate Metering Compartment, Phase Indications, Safety Features And Items Including Necessary Earthing Throughout The Bottom Length, 6 Sq.Mm Frls Copper Wire Interconnections For Compartment Earthing, Complete Copper Control Wiring With Crimping Type Ferrules, Copper Lugs, Proper Engravation On Each Compartment Etc. Also The Cost Inclusive Of Ms Base Frame, Steel Support Structure Required For Erection And Its Painting, Minor Civil Works, Vendor Drawings, Necessary Safety Clearance From Statutory Authorities, Panel Approval Fromceig/Tneb/Tangedco Till Obtaining Final Power Supply, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. All The Mccbs With Micro Processor / Thermal Magnetic Releases And Have Rotary Handle Mechanism. Each Compartment/Section Shall Have Exhaust Fans The Incoming Shall Have Metering, Ammeter & Voltmeter With Selector Switches, Ryb Indication Lamp With Control Mcbs And 8 Stage Apfc Relay Etc. Each Outgoings Shall Have Set Of Capacitor Duty Contactors, Set Of On/Off Indication Lamps And Set Of On/Off Push Button Etc. Incomer:(I)32A 4P 10Ka Mcb C Curve- 1 No Bus Bar:100A, Tpn, 25Ka, For 1 Sec Aluminium Bus Bar(I) Phase: Current Density Not More Than 0.8A/Sq.Mm(Ii)Neutral: Half Of The Phase Current (0.5 X Phase) (Iii) Earth : 25 X 3 Mmcopper Flat Outgoing:(I)3 Kvar Feeder Fitted With 25A Tp 10Ka Mcb - 1 No. (Ii) 2 Kvar Feeder Fitted With 20A Tp 10Ka Mcb - 1 No.(Iii) 1 Kvar Feeder Fitted With 20A Tp 10Ka Mcb - 5 Nos , Lt 3 Phase Metering Panel Lt 3 Phase Metering Panel With Tpn Fuse And Metering Provisions For 1 No As Per Tneb Standard With Double Earthing.100A,Rwf Fuse (3Nos) + Neutral Link- 1 Set 100A, Fp, 25Ka, Mccb With Adjustable Thermal Magnetic Releases And Rotary Handle Mechanism & Spreader - 1 No. , Part-Elt Cabling Supply, Laying, Testing And Commissioning Of Following 1.1Kv Grade Multicore Aluminium Conductor Xlpe/Pvc Insulated Gi Round(Upto 10Sqmm) / Flat(16Sqmm And Above) Armoured Pvc Sheathed Cables (Without Any Cable Joint) Drawn Through Tray Or Steel Supports Or Clamping On The Ceiling/Wall Or Pre-Excavated / Pre-Formed Trenches Or Gi Pipe Sleeves / Hume Pipes With Suitable Clamping Arrangement And Fixing Accessories, Cable Routemarkers, Cable Ties, Identification Tags Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 3.5C X 50 Sq.Mm Aluminium Xlpe Cable , (Ii) 3.5C X 35 Sq.Mm Aluminium Xlpe Cable , (Iii) 4C X 16 Sq.Mm Aluminium Xlpe Cable , (Iv) 4C X 10 Sq.Mm Aluminium Xlpe Cable , (V) 4C X 6 Sq.Mm Aluminium Xlpe Cable , Supply, Laying, Testing And Commissioning Of Following 1.1Kv Grade Multicore Copper Conductor Xlpe/Pvc Insulated Gi Round(Upto 10Sqmm) / Flat(16Sqmm And Above) Armoured Pvc Sheathed Cables (Without Any Cable Joint) Drawn Through Tray Or Steel Supports Or Clamping On The Ceiling/Wall Or Pre-Excavated / Pre-Formed Trenches Or Gi Pipe Sleeves / Hume Pipes With Suitable Clamping Arrangement And Fixing Accessories, Cable Routemarkers, Cable Ties, Identification Tags Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 4C X 10 Sq.Mm Copper Xlpe Cable , (Ii) 4C X 6 Sq.Mm Copper Xlpe Cable , (Iii) 4C X 4 Sq.Mm Copper Xlpe Cable , Supply And Termination Of The Following Sizes Of 1.1Kv Xlpe/Pvc Insulated Al/Cu Conductor Cables With Single Compression Brass Cable Glands And Tinned Copper Lugs Including Gland Earth Clips, Adequate Size Of Bare Copper Wire Connecting To The Main Bus Bars Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 3.5C X 50 Sq.Mm Aluminium Xlpe Cable , (Ii) 3.5C X 35 Sq.Mm Aluminium Xlpe Cable , (Iii) 4C X 16 Sq.Mm Aluminium Xlpe Cable , (Iv) 4C X 10 Sq.Mm Aluminium Xlpe Cable , (V) 4C X 6 Sq.Mm Aluminium Xlpe Cable , (Vi) 4C X 10 Sq.Mm Copper Xlpe Cable , (Vii) 4C X 6 Sq.Mm Copper Xlpe Cable , (Viii) 4C X 4 Sq.Mm Copper Xlpe Cable , Supply And Erection Of Following Size Of Hot Dip Gi Ladder Type Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Right Angles, Cross Members And Other Accessories Etc. The Item Including Cost Of Steel Support Structures At Every 0.6M/1M Intervels As Required For Suspend From The Ceiling Or Supported From Walls With Ms Suspenders/Brackets And All Complete With Painting/Powder Coating Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. (I) 150 X 50 X 2Mm , (Ii) 200 X 50 X 2Mm , (Iii) 300 X 50 X 2Mm , Supply And Erection Of Following Size Of Perforated Gi Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Right Angles, Cross Members And Other Accessoriess Etc. The Item Including Cost Of Steel Support Structures At Every 0.6M/1M Intervels As Required For Suspend From The Ceiling Or Supported From Walls With Ms Suspenders/Brackets And All Complete With Painting/Powder Coating Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. (I) 150 X 50 X 2Mm Without Cover , (Ii) 200 X 50 X 2Mm Without Cover , (Iii) 300 X50 X 2Mm Without Cover , (Iv) 450 X50 X 2Mm Without Cover , Laying Cables Buried Underground At 750Mm. From Fgl Including Necessary Excavation, Supply And Placingof Cable Markers And Backfilling In Compacted Layers, All Complete As Per Specifications, Drawings And /Or As Directed By The Engineer. , Supply, Installation Of Following Sizes Of Heavy Duty Pvc Pipe For Cable Crossing Of Basement Cable Entry & External Lights And The Like, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. (I) 50Mm Dia , (Ii) 100Mm Dia , Supply, Installation Of Following Sizes Of Hume Pipes For Cable Crossing Of Drains, Roads, Sanitary And Water Supply Lines And The Like, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. 150Mm Dia , Supply And Erection Of Following Size Of Pvc Trunking Channelincluding Horizontal And Vertical Bends, Joints,Tees, Angles, Cross Members And Other Accessoriess Etc. The Item Including Cost Of Support Clamping At Every 0.6M/1M Intervels As Required For Wall / Floor Mounting System And All Complete Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. (I) 50 X 80 Mm , (Ii) 50 X 105 Mm , Part-F Diesel Generator Supply, Unloading & Handling, Erection, Testing And Commissioning Of Following Ratings Of Dg Set With Standard Accessories Coupled To Alternator, 3 Phase, 4 Wire, 0.8 Pf (Lag), 415 V Mounted On A Channel Iron Base Frame With Foot Mounting Avm Pads, Fuel Tank (In Built), Charged Battery With Leads, Silencer Along With Exhaust Stack Raised Above Terrace Level(Avg 30M), Composite Type Acoustic Enclosure And Standard Control Panel. The Governor Shall Be Of Electronic & Mechanical Type And The Items Including Erection Of Amf Panel And Complete With Necessary Control Wiring/Cabling, Metering, Indication Lamps And Fixing Accessories Etc. 30Kva , Part-G Ups/Inverter Supply, Erection, Testing And Commissioning Of 1 Phase, 230 V, 1Kva 1P -In 1P Out Ups With Suitable Bcb (Battery Circuit Breaker), Filters, Suitable Tublers Batteries With 30Minutes Backup With Necessary Fixing Accessories Etc. , Supply, Erection, Testing And Commissioning Of 1 Phase, 230 V, 3Kva 1P -In 1P Out Ups With Suitable Bcb (Battery Circuit Breaker), Filters, Suitable Tublers Batteries With 30Minutes Backup With Necessary Fixing Accessories Etc. , Part-H Earthing Supply, Installation, Testing And Commissioning Of Earth Station Comprising Of 50Mm Outer Diameter And 3 Meter Length Of Copper Safe Earth Electrode, Including Approved Clamps, Bolts & Nuts, 450M X 450Mm Brick Masonary Chamber, Heavy Duty Ci Cover, Homogeneous Layers Of Earth Enhancing Backfilling Materials (Bentonite/Fly Ash) Are Placed Around The Earth Pipe As Per Standards (Is 3043), The Items Including Cost Of Excavation, Backfilling Of Earth Etc. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Installation, Testing And Commissioning Of Earth Station Comprising Of 50Mm Dia 3 Meter Long Galvanised Iron Pipe Earth Electrode And 25X3mm Copper Flat, Including Approved Clamps, Bolts, Nuts, Special Backfill Compound (Bentonite/Fly Ash), 450Mm X 450Mm Brick Masonary Chamber, Heavy Duty Rcc / Ci Cover, Drilling Into All Types Of Earth And Rock, Any Excavation And Backfilling, All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying, Testing And Commissioning Of Following Sizes Of The Earth Conductors For The Electrical System Which Including Cost Of Supply And Fixing Of Saddles, Insulators, Clamps, Screws, Bolt & Nuts And Providing Earth Work Of 2 Depth, Sleeves Wherever Required Etc., All Complete As Per Specifications, Drawings And/Or As Directed By The Engineer. (I) 25X6mm Hot Dip Gi Flat. , (Ii) 25X3mm Copper Flat. , (Iii) 300Mm Long 25X6mm Hot Dipped Cu Flat. , (Iv) 25X3mm Hot Dip Gi Flat. , (V) 8 Swg Copper Wire. , (Vi) 10 Swg Copper Wire. , Part-I Safety Accessories Supply And Installation Of The Following Safety Accessories To Be Installed In The Electrical Panel Room. First Aid Box. (Is Marked - As Per Standard Requirement) , Supply And Fixing Of 6 Kgs Co2 Type (Isi Marked) Fire Extinguisher Complete With All Clamps And Hardwares Etc. , Supply And Position Of 1.1 Kv Grade 2Mtr X 1Mtr Rubber Mat For Lt Switch Boards To Suit The Switch Board. (As Per Standard & Isi Marked) , Supply And Fixing Of Shock Treatment/First Aid Treatment Chart In Tamil, Hindi And English, Complete With Necessary Fixing Accessories Etc. , Part-J Telephone System Supply And Fixing Of Rj-11Modular Type Outlet Mounted On Suitable Zinc-Passivated Metal Box For Telephone Complete With Metal Box, Front Plate, Screws And Fixing Accessories Etc.,The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same Incase Of Recessed Mounting And All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply And Fixing Of Rj-45 (Cat-6) Modular Type Outlet Mounted On Suitable Zinc-Passivated Metal Box For Telephone Complete With Metal Box, Front Plate, Screws And Fixing Accessories Etc.,The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same Incase Of Recessed Mounting And All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply And Laying Of High Quality Cat-6 Ethernet Lan Cable Preferably With Fr Pvc Insulation To Be Laid In Existing Tray/Raceways/ Conduit From Individual Telephone To Network Jack/Switch/Patch Panel/Hub Located In The Communication Room. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying And Termination Of Following Sizes Of Telephone Cable Laid In Exitingconduit/Tray/Raceways From Krone Junction Box To Other Krone Junction Box/Epabx Etc.And All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. 2 - Pair Cable , 5 - Pair Cable , Supply And Fixing Of The Following Telephone Krone Type Junction Boxes Enclosed In Ms Box With Hinged Cover With Lock & Key Arrangements Etc.The Item Including Necessary Clamping And Making Good The Same In Case Of Recessed Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. 5 - Pair Kjb , Part-Kdata Networking System Supply And Fixing Of Rj-45 Modular Type Data Outlet (Cat-6A) Mounted On Suitable Zinc-Passivated Box Complete With Metal Box, Front Plate, Screws And Fixing Accessories Etc.The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply Andlaying Of High Quality Cat-6A Ethernet Lan Cable Preferably With Fr Pvc Insulation To Be Laid In Exisitng Tray/Conduit/Racewaysfrom Individual Data To Network Jack/Switch/Patch Panel/Hub Located In The Communication Room.All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying And Termination Of High Quality Armoured Optical Fiber (48 Fibers) Along With The All Accessories Connectors, Switches Etc , Fixing Of Modular Type Information Outlet (For Wi-Fi) With Necessary Fixing Accessories. The Item Including Necessary Chipping/Cutting The Wall And Making Good The Same In Case Of Flush Mounting As Required. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Laying And Termination Of 6 Pair Fibre Optic Cable Laid In Existing Conduit/Tray/Hume Pipe With The All Necessory Accessories As Required. , Supply, Laying And Termination Of Hdmi Cable Of 15 Meters In Length Laid In Existing Conduit/Tray/Hume Pipe With The All Necessory Accessories As Required. , Supply, Laying And Termination Of Hdmi Cable Of 15 Meters In Length Laid In 40Mm Pvc Pipe With The All Necessory Accessories As Required. , Supply, Fixing , Testing And Commissioning Of 24 Port Switch Patchpanelwith The All Necessory Accessories As Required. , Part-Lclosed Circuit Television System Supply, Laying And Termination Of High Quality Cat-6 Ethernet Lan Cable Preferably With Fr Pvc Insulation To Be Laid In Existing Pvc Pipe From Individual Cctv Camera Outlets To Network Jack/Switch/Patch Panel/Hub Located In The Communication Room. All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supplying And Installing Wall Or Ceiling Mounted Outdoor Type Fixed Dome Ip Camera With 1/3” 4Mp Ps Cmos Image Sensor 4Mp@25/30Fps (2560 × 1440), Ir Range Of 30 Mtrs,. The Items Inclluding Necessary Fixing Accessories. , Supplying And Installing Wall Or Ceiling Mounted Indoor Type Fixed Dome Ip Camera With 1/3” 4Mp Ps Cmos Image Sensor 4Mp@25/30Fps (2560 × 1440), Ir Range Of 30 Mtrs,. The Items Inclluding Necessary Fixing Accessories. , Supply, Fixing And Termination Of High Quality Rack Mounted Type Patch Panel With One Number Of 16 Port Poe Network Switch, Fixing Frames, Links And Interconnections, Necessary Accessories Etc., All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supply, Fixing And Termination Of High Quality Floor Mounted Type 6U Floor Mountable Powder Coated Rack With 3X5a Power Manager, 1 Position Fan, Min 1 Nos Of Shelf, Front Glass Double Door With Lock & Key With Suitable Network Port Switch, Fixing Frames, Links And Interconnections, Necessary Accessories Etc., All Complete As Per Specifications, Drawings And / Or As Directed By The Engineer. , Supplying And Installing Of 16 Channel Network Video Recorder With Max 320Mbps Incoming Bandwidth Smart H.265+/H.265/ Smart H.264+/H.264/Mjpeg Up To 12Mp Resolution Preview And Playback Support 8 Sata Hdds Up To 10Tb Each, 4 Usb (2 Usb3.0, 2Usb2.0) 2 Hdmi / 2 Vga Simultaneous Video Output Support Multi-Brand Network Cameras Support Raid 0/1/5/10 Mobile Software: Icmob, Gcmob Cms Software: Kvms Pro. The Items Including Supply Of 4Tb Hard Disk, Connectors, Pins And Providing Complete Configuration Etc. , Supplying And Installing Of Power Supply Unit Along With Necessary Battery Backup, Suitable For 1 Nos. 16 Channel Network Video Recorder System. , Supplying And Installing Of 32 Led Colour Monitor. , Part-M-Miscellaneous Liasioning With Tneb Including Submission Of Application & Documents For Obtaining Required Additional Demand Power. (Appx. Cost) , Hvac System Supply, Installation,Gas Charging, Testing And Commissioning Of Modulating Outdoor Units, With Multi Scroll/Rotary Compressorswith One Capacity Controlling Compressor, Special Pre-Coated Fins, Panel, Corrosion Resistant (Suitable For Seaside Installation) Coated Condenser, Inverter Based Condenser Fan Mounted As Indicated In The Drawing, Electrical & Microprocessor Panel, Isolating Valves And All The Necessary Accessories For Proper Functioning Of The Units, Having Following Approximate Capacities. Indicate For All Port Charges, Port Handling Charges, Other Local Duties, Loading, Transportation /Insurance Up To Site, Octroi Charges And All Other Taxes And Incidentals Complete Till Delivered At Site. Customs Duty And Countervailing Dutyfor The Above Imported Equipment. Receiving At Site Above Imported Equipment, Unloading, Storing, Handling Hoisting, Installing In Position, Effecting Connections, Anchoring, Grouting Testing And Commissioning Above Equipment Including Supplying And Installing All Necessary Indigenous Accessories As Required To Complete The Installationnote : Fins And Copper Tubes Of Air Cooled Condenser Alongwith Copper Tubing / Piping With All Joints And U-Bends Exposed To Coastal Areas Corrosive Atmosphere / Aggressive Ambient, Shall Be Painted With Special Orrosion Prevention Coating Either In Factory Or At Site. 14 Hp Odu Units , Supply,Erection, Testing And Commissioning Of Vrf Based Ductable / Fcu Type Indoor Units Complete With Remote And All Accessories,Vibration Isolators & Supports. The Each Indoor Units Shall Be With Potentilal Free Contactor To Connect With Bms. (I) 5.0 Tr With Wired Remote- Ductable , (Ii) Ceiling Mounted Fan Coil Unit - 2.56 Tr With Wired Remote- Fcu , (Iii) Cassette Type Unit - 1.32 Tr With Wireless Remote , (Iv) Hiwall Type Unit - 1.0 Tr With Wireless Remote , Supply, Installation., Testing And Commissioningof Centralized Remote Controller , Supply,Erection , Testing And Commissioning Of All Refrigerant Joints ( Necessary Filling Of Refrigerant Gas In Circuits, Ref. Pipe Pressure Test Etc.). , Supply, Installation, Testing And Commissioning Of Hiwall Splitunit Air Conditioner Comprising Indoor And Out Door Unit Interconected At Field By Refrigerant Piping. The Refrigerant Shall Be Working Onnon Cfc Based R407c/R410 A/R134a Refrigerant. The Indoor Unit Shall Comprise Multirow Dx Cooling Coil, Nylon Pre-Filter, Centrifugal Blower With Drive Motor Mounted In An Aesthetically Pleasing High Quality Plastic Casing. The Out Door Unit Shall Comprise, Rotary / Scroll Compressor/S, Condenser Coil, Propeller Fan, Ip55 Motor All Housed In A Powder Coated Casing. The Fan Shall Be Selected For Low Noise And Shall Be Provided With Fan Guard. The Unit Set Shall Be Supplied With Apower Cum Control Panel Incorporating All Switchgear Required For The Machines Functioning Along With Over Load Relay Etc. The Price Shall Include Corded / Cordless Remote Controler, Installation Of The Units As Per Site Conditions And Charging Of Necessary Refrigerant & Oil If Required. Suitable Contactor To Enable Trip On Receiving Fire Alarm Signal To Be Provided. 1.0 Tr Hiwall Split (Server Room Standby Unit) , Supply, Installation, Testing And Commissioning Ofsoftron Refrigerant Copper Piping With Nitrile Rubber Tubular Insulationwith 13/19Mm Thicknesswith Glass Cloth And Poly Shield Coating Between Indoor To Outdoor Unitsand Supporting Arrangements Etc… Suitable Size For Above Mentioned Dx Hi-Wall Split Units . , Supply, Installation, Testing And Commissioning Of Hard/Soft Drawn Soft Refrigerant Piping Along With Insulation And Supports, Between Indoor & Outdoor Units Duly Insulated As Per Specifications.The Brazing To Be Carried Out With Bleeding Of Nitrogen. The Copper Pipe To Be Insulated With 19 Mm Thick / 13 Mm Thick Nitrile Rubber Sleeves Or Sheet Shall Be Properly Supported With Hanger And Exposed Piping Shall Be Properly Supported In Cable Tray. (I) 41.3 Mm , (Ii) 34.9 Mm , (Iii) 28.6 Mm , (Iv) 22.2 Mm , (V) 19.1 Mm , (Vi) 15.9 Mm , (Vii) 12.7 Mm , (Viii) 9.52 Mm , (Ix) 6.5 Mm , Supply And Laying Of 2C X 1.5 Sqmm. Control Cabling & Earthing As Per Specifications Between Out Door Unit & Indoor Units. The Cables Should Be Cross Linked Polythene Insulated, Armoured Copper Cabling With A Low Smoke And Flame Sheath . Power Supply (3 Phase 415 Volts Will Be Made Available Near Outdoor Units. Contractor To Provide Panel For Onward Power / Control Supply To Outdoor Units Andpower Supply Single Phase Will Be Made Availabe Near Indoor Units Contractor To Provide Power/Control Supply To Indoor Units, Supports, Trays Etc. , Supply And Erection Of 200(W) X 75(H) Size Of Flat Gi Cable Trays Including Horizontal And Vertical Bends, Reducers, Tees, Right Angles, Cross Members And Other Accessoriess Etc. The Item Including Cost Of Steel Support Structures At Every 0.6M/1M Intervels As Required For Suspend From The Ceiling Or Supported From Walls With Ms Suspenders/Brackets And All Complete With Painting/Powder Coating Etc. All Complete As Per The Specifications / Drawings Ad Or As Directed By The Engineer. , Machine Made Gss Ducting With Flanges, Neoprene Gaskets, Factory Made Supports, With Black Painting As Per Specifications (Factory Made With Ductmate Flanges) (I) 24 G Gi Ducts , (Ii) 22 G Gi Ducts , Supply And Installation Of Thermal Insulation 13Mm Thk Closed Cell Nitrile Rubber With Suitable Adhesive As Per Specification , Supply And Installation Of Accoustic Insulation 10Mm Thk Open Cell Nitrile Rubber With Suitable Adhesive As Per Specification , Supply And Installation Of 6 Ht Cont. Al. Powder Coated Grill For Supply And Return Air For Ductable Units , Supply And Installiion Of Gi Collar Damper 600 X150 Mm. , Supply And Installation Of Aluminium Powder Coated 3 Slot Diffuser With Hidden Mist Damper And Fixing Arrangements Etc… , Supply And Installation Of Aluminium Powder Coated Fresh Air Louver With Bird Screenanddamper And Fixing Arrangements Etc… 200 X 200 Mm , Supply And Installation Of Fire Retardant Canvass Connection , Providing And Fixing In Position The Followingupvc Drain Pipes Cut To Required Lengths And Installed With All Screwed Joints, And Providing And Fixing In Position The Necessary Elbows, Tees And Reducers As Per Specifications And Shall Be Insulated With 6Mm Thick Nitrile Rubber. (I) 25 Mm , (Ii) 32 Mm , Supply, Installation, Testing And Commissioning Of Poly Shield Coating With Glass Wool Packing For Weather Proof , Fire Fighting System Supply, Install, Test And Commission Of Boosterpump Terrace Pump Located At Terrace Level, Capacity: 450 Lpm At 35 Mtr. With Pressure Of 3.5Kg / Sq.Cm At The Top Most Hydrant, Complete Head, Horizontal Centrifugal Pump With Bronze Impeller, Ss Shaft, Mechanical Seal,Coupled To 10Hp,2900 Rpm, Tefc, Squirrel Cage Induction Motor Complete Withm.S. Base Frame, Anti Vibration Pad, Foundation Bolts, Pressure Gauge, Pressure Switchwith Drain Valve,And All Other Necessary Fixing Accessories. , Supply, Erection, Testing And Commissioning Ofc Class M.S Heavyfor Downcomer System As Per Is : 1239 For Pipes With Welable Fittings, Valves Necessary, All Structural Supports And Accessories.The Quoted Rate Shall Be Includes One Coat Of Primer And Two Coat Enamel Paint Of Approved Colour And Also Chasing / Chipping Walls Making Bore Hole In Walls / Floor And Making Them Good With Filler Material And Finished In Cement Mortar Etc. Complete In All Respect. (I) 100Mm Nb , (Ii) 80Mm Nb , (Iii) 25Mm Nb , Supply, Erection, Testing Andcommissioning Of `Fire Hose Cabinet (Fhc) In Size Of 750Mm X 900 Mm X 250 Mm.Hinged Door Shutter And Frame And Fabricated Out Of 14 Swg Sheet Steel, Fitted With 4Mm Thick Toughned Glass With Rubber Beeding In The Front Including Finishing With Powder Coat Painting Complete. The Rate Shall Be Inclusive Of Stand For Mounting, All Fasteners Etc, And Cabinet Shall Be Powder Coated Finish Of Red Colour Both Inside And Outside. , Single Headed Hydrant Valve As Per Is 5290, Made Of Gun Metal With 63 Mm Dia Instantaneous Outlet Of 80 Mm Dia Fanged Inelt ,Blank Caps , Chain And Hand Wheels Etc Complete. , 15 M Long, 63Mm Dia Rrl Hose With Instantaneous Couplings And Hoses Shall Be Stored Inside The Hose Cabinet. , 1 No. Gun Short Branch Pipe With Nozzle. , Fire Hose Reel Drum (As Per Isi)Wall Mounted, Swinging Type 18 Swg Ms Sheet, Fitted With 19 Mm Dia X 36 M Long, High Pressure Hose With 5 Mm Outletnozzle With Shut Off Valve (Is: 884-1969) , One No 25Mm Dia Ball Valve , Supply, Fixing, Testing And Commissioning Of Fire Brigade Inlet (Pumping In Breech) Connection, Having Gunmetal Body With 1 Nos. 63 Mm Size Gunmetal Male Instantaneous Inlets (With Nrv), And 100 Mm Size Flanged Outlet, Suitable For Connection To Dry Riser Piping. Fire Brigade Inlet Body Shall Be Provided With Drain Valve. Fire Brigade Inlet Connection Shall Be Isi Approved , Supply, Erection, Testing And Commissioning Of Slimseal Typebutterflyvalves Withshperoidalgraphite Irondisc(Sg Iron), With Nitrile Rubber Sealand Tested Topn 16 Including A Set Of Suitable Gi Flanges, As Per Bs 10 Table - 1, Bolts, Nuts Gi Washers, Neoprene Rubber Gaskets Etc., Complete. 100Mm Nb , Supply, Erection, Testing And Commissioning Of Dual Plate Non-Return Valves With Ci Body &Upto 125Nb Pn 16 Including A Set Of Suitable Ms Flanges, As Per Bs 10 Table - 1, Bolts, Nuts Gi Washers, Neoprene Rubber Gaskets Etc., Complete. 100Mm Nb , Supply, Erection Testing & Commissioning Of Pot Strainer / Y Strainer With Ci Bodytested Topn 16 Including A Set Of Suitable Gi Flanges Rate Shall Include For Rubber Insertion, Bolts, Nuts Msflanges.100Mm Nb , Supply, Erection, Testing And Commissioning Of 25Mm Dia Air Release Valve. The Rate Shall Be Inclusive Of Accessories.25Mm Dia Air Release Valve , Supply, Installation, Testing And Commissioning Of Terrace Fire Pump Panel Withtype-2 Co-Ordination Dol Starters For The Booster Pump And Complete With Auto/Manual Switch, Timers, Rotary Switches, Indication Lamps, Enclosure Being Vermin & Dust Proof (Ip65), Necessary Alarms, Push Buttons, Etc. The Panel Shall Also Be Provided With Industrial Hooter For Alarm And Necessary Suitable Relays Shall Be Provided - 450 Lpm Pump , Automatic Detection And Manual Fire Alarm System Main Control Panel: Supply, Installation, Testing & Commissioning Of Microprocessor Based Intelligent Analogue Addressable, Modular,Expandable, Networkable, 02- Loopfire Alarmcontrol Panel With Minimum 640 Character Lcd Display, Multiple Access Levels, Event History File In Nos.N-Volatile Memory (Eeprom). The Panel Shall Support Programmable Relay For Controlling Lifts, Staircase Pressurizations Fans, Lift Shaft & Lift Lobby Pressurization Fans, Toilets Exhaust Fans, Ventilation Fans At Fire Pump Room, Monitoring Of Fire Hydrant Pump Controlled By Powerful Boolean Logic Equation. The Panel Shall Have 240 Volts Ac Power Supply, Automatic Battery Charger, 24 Volts, Sealed Lead Acid Maintenance Free Batteries Sufficient For 24 Hours Nosrmal Working And Then Be Capable Of Operating The System For 60 Minutes During Emergency Condition. The Panel Shall Be Ul Listed/ Fm Approved. , Supplying, Installing, Testing And Commissioning Of Loop Card , Supplying, Installing, Testing And Commissioning Of Sounder With Strobe Light , Supplying, Installing, Testing And Commissioning Of Addressable Manual Call Point With Back Box. , Supplying, Installing, Testing And Commissioning Of 2C X 1.5 Mm², Armoured, Single Stand, Outer Sheathed, Frls, Pvc Insulated Copper Conductor Cable Confirming To Specified Is Standards . , Supply, Installation, Testing & Commissioning Of The Following: Sensors Confirming To The Description,And Standards. (All Floors& Common Area) Supplying, Installing, Testing And Commissioning Of Addressable Photo Electric Smoke Detector (Optical) With Base, Junction Box And Other Accessories (True Ceiling & Above False Ceiling) , Supplying, Installing, Testing And Commissioning Of Rate Of Rise Heat Detector With Base, Junction Box And Other Accessories. , Supplying, Installing, Testing And Commissioning Of Addressable Photo Electric Multi Sensor Detector (Optical) With Base, Junction Box And Other Accessories. , Analogue Addressable Fault Isolator Module Capable Of Monitoring Shorted Loop Circuit And Automatically Restore Communications When Shorted Conditions Are Corrected , Response Indicator For All Detectors Located Above False Ceiling For Visual Identificaion Of Detector , Supplying, Installing, Testing And Commissioning Of Analogue Addressable Monitor Module (Single Input Module) For Integrating Sprinkler Flow Switch In All Floors And Status Of Fire Pumps With Facp At Ground Floor. , Supplying, Installing, Testing And Commissioning Of Addressable Control Module For Activating The Notification Application Devices. Shall Have Supervisory Facility To Supervise The Auxillary Power Supply As Well As The Notifcation Appliance Circuits..Shall Have Binary Coding Setting Dp Switches, Shall Have An Led Indication Fornormal Working And Active Modes -Approval: Ul Listed , Supplying, Installing, Testing And Commissioning Of Power Supply Unit Which Provides 24V Dc Output For Connecting All Relay Control Modules And Other Modules. The Power Supply Unit Will Be Located In Fire Control Room At Ground Floor And In Designated Location Preferably Near To Fa/Pa Shaft In Typical Floors. , Fire Extinguishers Supplying, Installing And Commissioning Portable Fire Extinguishers Of Following Type & Capacity. (I) Carbon-Di- Oxide Type Fire Extinguisher Of 4.5 Kgs. Capacity, Co2 Gas As Per Is 15222 With Controll Discharge Mechanism Fitted With Hose & Horn Applicable On Class B Fire Rating 21Bconfirming To Is: 15683. , (Ii) Abc Powder Type Fire Extinguisher Of 4 Kgs. Capacity, With Initial Filling (Mono Ammonium Phospate Powder 90) In Brand New Cylinder With Powder Coated Finish, Stored Pressur Type, Pressure Gauge, Controllable Discharge Mechanism With Hose & Nozzle , Confirming To Is:15683. (Abc Dry Chemical Powder- Map 90%) , Signages Providing And Installing In Position The Following Tupe Of Sign Boards Made Out Of 3Mm Thick Opaque Pvc Foam Board With Computer Cut. Pvc Non-Reflective Self Adhesive Vinyle Painted Foam Board, Complete With Mirror Fasteners. Signages With Printed In Case Of Fire, Use Stairs Unless Instructed Otherwise Of 1.5Cm Height Letters In Red With White Back Ground. The Size Of The Board Shall Be 25Cm * 30Cm And Shall Be Fixed At The Height Of 2Mts, From Finished Floor Near Manual Call Points. , Providing And Fixing In Position The Signage Of Incase Of Fire Do Not Use Lift Size 8 X 8 , Providing And Fixing In Position The Signage Of Incase Of Fire Break The Glass To Be Pasted Immediately Above The Every Extinguisher.Size 6 X 6 , Providing And Fixing In Position The Signage Of Fire Extinguisher To Be Pasted Immediately Above The Every Extinguisher.Size 6 X 6 , Providing And Fixing In Position The Signage Of Fire Hydrant & Hose Reel To Be Pasted On Door Of The Every Fire Shaft At All Floors. . Size 6 X 8 , Providing And Fixing In Position The Sign Board Of Assembly Point Complete With 1 Mm Thick Rigid Plastic Board Size Of 600 Mm X 600 Mm To Be Fixed On Ground By Using A Steel Rod / Pipe At Designated. , Providing And Fixing In Position The Signage Of Fire Alarm Panel Size 6 X 6 , Providing And Fixing In Position The Signage Of Exit Signages Glow Type With Battery Backup Size 8 X 16 , Providing And Fixing In Position The Signages Fire Order It Should Contain The Following Matter On 3Mm Thick Opaque Pvc Foam Board Of Computerised Cut, Pvc Non-Reflective Self Adhesive Vinyle Painted Foam Board Of 3 * 4 , Type -I Comprising The Followinga) Alert The Security At Security Room By Actuating Manual Call Point Located At Strategic Locations.B) Evacuate The Occupants By Using Fire Exits And Emergency Exits Only And Assemble At Various Assembly Points.C) If Possible Try To Extinguish The Fire By Using Nearest / Suitable Portable Extinguisher Or Water From Nearest Wet Riser.D) Be Calm And Do Not Give Any Room From Panic, Walk, Do Not Run. E) If You Encounter Serious Difficulty In Evacution, Flat And Try To Attract Attention Of Rescue Team. , Type -Ii Comprising The Following Action By Security / Reception Upon Receipt Of Information Through Fire Alarm Or Fire Detectors Or By Using Public Address System. A) Alert The Occupants By Using Public Address System.B) Inform Fire Control Through Any One Of The Following Phone Numbers: 101, Xxxxxxxxxxxxxxxxxxxxc) Refer Evacution Plan From Evacuating Standard People.D)Guide The Fire Force, On Their Arrival To The Seat Of Fire E) In Case Of The Casualities, Call Ambulance By Dialling Number……………. , Laisoning Works: Laisoning Charges For Works Such As Filling Necessary Applications, Prepration Necessary Drawings And Submitting For Approval With Requestion Form Of Local Fire Force Department, Arranging For Inspection Of Fire Hydrant Installationsand Equipmentsbyfireforce Officers Authority Includiungnecessary Follow - Up Withconcerned Person Uptilloccupation Certifice (Oc) Is Obtained.The Scope Of Work Shall Also Include Depositing The Fees, Other Amounts As And When Required. All The Expense Incurred In Authorities Following - Up In This Regard Shall Be Borne By The Sub - Contrtactor Except For The Payments To Be Made For Only Security Deposit On Pro Rate Basis Etc., Which Will Be Reimbursed On Production Of Original Vouchers. , Lift Works: 2 Stops-Sound Proof 360° Panoramic Glass View Curved Designer Profile No Connector Holes On The Shaft Joints Cylinder Joint Cover - Matching Designer Profile Concealed Hinges With No Projected Visible Metal Cover Invisible Sensors On The Shaft Cabin Colour Matching To Lift Colour Panoramic Frameless Aluminium Door Door Handles Painted To Match Lift Colour Cabin Base Cover Plates Zero Visible Screws On Shaft / Cabin & Doors No Visible Springs On Cabin Basesafety Dual Hcc Brakes (Hardened Cross Compound) Electric Door Lock For Safety Triangle Emergency Alarm Cabin Phone With Gsm Child Safety Switch Cabin Internal Diameter= 1160Mm Height=1930Mm Clear Acess=805Mm Handle=No , Flodable Chair=No Alexa = No Capacity = 240Kg Colour = Cream White Flooring Carpet = Beigelanding Door Floor 0 =F0 Access=Side A Automatic Door Closing Right Hand Side Hinge Floor 1 - F1 Access - Side A Automatic Door Closing Right Hand Side Hinge Shaft External Diameter = 1365Mm Space Requried =1430Mm Color = Cream White Power Reuirementsingle Phase - 230V - 50/60Hz 32Amp With Circuit Breaker Stabilized Power Travel Height From F0 To F1 = 3500Mm Total Travel Height From F0 To F1 = 3500Mm Minimum Headroom Required = 2439Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
48.
Defence #9130910 AOC
Tender For Repair Replacement Of Certain Parts Of Summer And Winter Appliances At Rajouri Under Ge 862 Ews - REPAIR OF GEYSERS:-Disconnecting and removing from position for repair of geyser of any capacity , replacement of glass wool, element, thermostate, water tank, flange assembly etc, cleaning internally and externally including checking for leakage in tank and rectification by gas welding, replacement of gasket, nuts, bolts and clamps, reassembling and refixing in position complete to the entire satisfaction as specified and directed.Note :- (i) Cost of gas welding, nuts, bolts and clamps etc shall be deemed to be inclusive in unit rate quoted by the tenderer. (ii) Replacement of unserviceable parts shall be measured andpaid for separately under respective item as supply only. 2 Supply only of heating element3.0 KW (for solar water), complete all as specified and directed. 3 Supply only of heating element2.0 KW, complete all as specified and directed. 4 Supply only of heating element1.5 / 1.00 KW, complete all as specified and directed. 5 S&F in replacement PVC insulated & PVC sheathedmulti stranded copper conductor cable flexible3 core, 2.5Sqmm complete all as specified and directed. 6 Supply only thermostat ranging 60 degree to 90 degree adjustable type,operative on 250 Volts, complete all as specified and directed. 7 Supply only indicator lamp,round/square, green/red as per requirement, complete all as specified and directed. 8 Supply only inner tank made out of stainless steel of standarad gauge for 25 to 35 litres capacity geysers, ISI marked, complete all as specified and directed. 9 Supply only inner tank made out of stainless steel for 50 litres capacity geysers, ISI markedcomplete all as specified and directed. 10 Supply only geyser syphonassembly chromium plated suitable for 50 litres capacity geysers ISI marked complete all as specified and directed. 11 Supply only geyser syphonassembly chromium plated suitable for 25/35 litres capacity geysers ISI marked, complete all as specified and directed. 12 Supply and fix in replacement PVC connection heavy duty connecting withtwo Nos ofadopter and washer of size 450 to 600 mm longsuitable for geyser and including all fixing accessories, complete all as specified and directed. 13 Supply and fix in replacement of sheet metal enclosureswith two pin and earth plug and socket complete with single pole MCB 20 Amps complete all as specified and directed. 14 REPAIR TO FANS:- Taking down carefully ceiling fans 1200/1400 mm sweep and exhaust fan/pedestal/air circulator any sweep, from various bldgs (or collecting from MES E/M Store Yard) as directed, opening up for servicing/repair, removing dust and dirt ,cleaning fan motor with cotton/waste malmal, washing blades with detergent powder, greasing to serviceable bearings, checking of nuts,bolts, washer, rubber buff, split pin, condensers, MS clamps, rubber packing, condensers block, rubber reel etc for any damages and replacement of damaged and unserviceable items for the smooth and satisfactory functioning, re-fixing fans etc in position, connecting to electric system and testing complete all as specified and directed. Note:- Replacement of damaged/unserviceable parts shall be measured & paid seprately. 15 M&L for rewinding of ceiling fan motor 240 volt, 50 Hz, 1200 mm sweep of any make with super enameled copper winding wire of existing size including sleeve work, varnishing with ‘B’ class insulation varnish, connection with flexible copper wire 0.472mm dia upto connector block including cutting down and removing complete burnt winding after inspection complete all as specifiedand directed. Note:- Motor shall be wound with machine with same No of turns as per existing. 16 M&L for rewinding of ceiling fan motor 240 volt, 50 Hz, 1400 mm sweep of any make with super enameled copper winding wire of existing size including sleeve work, varnishing with ‘B’ class insulation varnish, connection with flexible copper wire 0.472mm dia upto connector block including cutting down and removing complete burnt winding after inspection complete all as specifiedand directed. Note:- Motor shall be wound with machine with same No of turns as per existing. 17 M&L for rewinding of exhaust fan motor 240 volt, 50 Hz, 300 mm sweep of any make with super enameled copper winding wire of existing size including sleeve work, varnishing with ‘B’ class insulation varnish, connection with flexible copper wire 0.472mm dia upto connector blockincluding cutting downand removing complete burnt winding after inspection complete all as specifiedand directed. Note:- Motor shall be wound with machine with same No of turns as per existing. 18 Description all as per srl item No 17 here-in-before, but exhaust fans of 450 mm sweep. 19 Supply and fixing in replacement capacitor AC 415 volts 4 mfd 50 HZ, complete all as specified & directed. 20 Supply and fixing in replacement capacitor AC 415 volts 2.5 /3.15 mfd 50 HZ complete all as specified and directed. 21 Supply and fixing in replacement of fan blade of 1200mm sweep (as per sample), complete all as specified and directed. 22 Supply and fixing in replacement of fan blade of 1400mm sweep (as per sample), complete all as specified and directed. 23 S&F in replacement for PVC insulated three core twisted copper flexible cable of size 1.5 sqmm, 3 core from connector block to ceiling rose and making connection, complete all as specified & directed. 24 S&F in replacement of wall mounted fan AC single phase 230/240 volts, 5 star rated and accessories 400mm sweep, with suiable handing arrangement for fan, complete all as specified and directed. 25 S&F in replacement of PCB (printed control board) sensor for BLDC motor ceiling fan 1200mm, complete all as specified and directed. 26 REPAIR TO REFRIGERATOR:-Dismantling refrigerator/deep freezer of any make capacityfor taking out compressor/condenser/freezer unit etc. for repair/ replacement of unserviceable parts, cleaning condenser/ freezer unit of foreign particle and descaling with carbon dioxide gas to ensure smooth flow of refrigerant gas, reassembling the appliance, testing and placing in position complete all as specified and directed. Note: Repair/ replacement of unserviceable parts shall be measured & paid separately as supply only. 27 Supply only hermetically sealed compressor unit 1/8 HP for 165/175 Ltr refrigerator complete all as specified and directed. 28 Supply only hermetically sealed unit compressor 1/6 HP for 280 to 310 Ltr refrigerators complete all as specified and directed. 29 Supply only PCB (printed control board) and sensor complete all as specified and directed. 30 Supply and filling of refrigerant gas R-134A of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters complete all as specified and directed. 31 S&F in replacement starting relay of refrigretor any capacity complete all as specified and directed. 32 S&F in replacement over load protector for refrigerator, any description complete all as specified and directed. 33 S&F in replacement Thermostat of refrigretor of any capacity complete all as specified and directed. 34 REPAIR TO WATER COOLERS:-Dismantling water cooler for taking out compressor/ condenser unit etc. for repair/replacement of unserviceable parts, cleaning condenser unit of foreign particle and descaling with carbon dioxide gas to ensure smooth flow of refrigrant gas, reassembling the appliance, testing and placing in position complete all as specified and directed. Note: Repair/ replacement of unserviceable parts shall be measured & paid separately under respective items of BOQ as supply only. 35 Supply only hermetically sealed compressor unit 1/6 HP for 80/120/150 Ltr capacity water cooler complete all as specified and directed. 36 Supply and filling of refrigerant gas R-22 of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters complete all as specified and directed. 37 S&F in replacement starting capacitor 60-80 mfd complete all as specified and directed. 38 S&F in replacement running capacitor 15 mfd complete all as specified and directed. 39 S&F in replacement thermostat for water cooler any description complete all as specified and directed. 40 S&F in replacement starting relay for water cooler any description complete all as specified and directed. 41 REPAIR TO AC WINDOW TYPE:-Dismantling and taking out compressor/condenser unit/blower motor etc. from window type AC of capacity 1.5 TR and for repair/replacement of unserviceable parts, cleaning condenser unit of foreign particle, reassembling the appliance, testing and placing in position complete all as specified and directed.Note: Repair/ replacement of unserviceable parts shall be measured & paid separately. 42 M&L for complete servicing of Window AC 1.5/2 Ton Cap.including disconnecting setting a-side cleaning dust particles with blowers and cleaning the condensor fins with chemical and finally with water, rescumbling and testing, complete all as specified and directed. 43 S&F in replacement hermetically sealed compressor unit for AC 1.5 Ton complete all as specified and directed. 44 Taking out old unserviceable blower with fan motor from window type AC 1.5 ton capacity and providing new blower fan motor double shaft, 3 speed, single phase, AC, 1/5 HP, 920 RPM complete all as specified and directed. 45 S&F in replacement starting capacitor 100-120 mfd for AC any description complete all as specified and directed. 46 S&F in replacement starting relay SR-1622 for AC any description complete all as specified and directed. 47 S & F in replacement strip type heater(M type)2 KW for window type Accomplete all as specified and directed. 48 S&F in replacement running capacitor 36 mfd complete all as specifiedand and directed. 49 REPAIR TO AC SPLIT TYPE:-Dismantling and taking out compressor/condenser unit/blower motor etc. from split type AC of capacity 1.5 to 2.0 TR and for repair/replacement of unserviceable parts, cleaning condenser unit of foreign particle, reassembling the appliance, testing and placing in position complete all as specified and directed.Note: Repair/ replacement of unserviceable parts shall be measured & paid separately under respective item of BOQ. 50 M&L for complete servicing of Split AC 1.5/2 Ton Cap.including disconnecting setting a side cleaning dust particles with blowers and cleaning the condensor fins with chemical and finally with water, reassembling and testing, complete all as specified and directed. 51 S&F in replacement condensor Fan motor complete for AC 1.5 to 2.0 Ton complete all as specified and directed. 52 Rewinding with super enameled copper winding wire of standarad gauge, blower motor including replacement of ball bearing,insulating material complete for AC 1.5 to 2.0 Toncomplete all as specified and directed. 53 S&F in replacement of PCB (printed control board) Dule mode and sensor, complete all as specified and directed. 54 S&F in replacement of running capacitor (capacity 40/50 mfd) complete all as specified and directed. 55 S&F in replacement hermetically sealed compressor unit for 1.5 Tonsplit type AC, complete all as specified and directed. 56 S&F in replacement hermetically sealed compressor unit for 2.0 Tonsplit type AC, complete all as specified and directed. 57 Supply and filling of refrigerant gas R-134A of required quantity including detection and rectification of leakage before charging of gas into compressor including replacement of filters complete all as specified and directed. 58 REPAIR TO DEEPFREEZER:-Dismantling of deep freezer for taking out compressor/ condenser/freezer unit of foreign particle and descaling with carbondioxide gas to ensure smooth flowof refrigerant gas, reassembling the appliance , testing and placing in positioncomplete all as specified and directed. Note:- Repair/replacement ofunserviceable parts shall be measured and separately. 59 Supply only hermetically sealed compressor unitfor 1/6 HP for 310 Ltr deep freezer. Complete all as specified and directed. 60 Supply only starting relay completesuitable for deep freezer, complete all as specified and directed. 61 M&L for replacement of over load protector for deep freezer of capacity 310 ltrs, complete all as specified and directed. 62 M&L for replacement of thermostat of capacity 310 ltrs, complete all as specified and directed. 63 M&L for replacement of filter suitable for deep freezer of any make and capacity, complete all as specified and directed. 64 M&L for replacement of condenser fan motor, complete all as specified and directed. 65 Repairs to industrial type RO plant of capacity 500 liters per hour of any type make by dismantling and carry out servicing and overhauling and making functional after throughly examine/checking all components, inlet and outlet piping system, descaling complete,pressure meter, auto flushing (solenoid valve), automatic ON/OFF, indicators and anti scalant dosing system etc and replacement of spare parts/components viz 500 GPD membrane, filter set, adoptor, motor, solenoid valve, and pipe coupling set and testing for its performance complete all as specified and directed.Note:-500 GPD membrane, filter set, adopter, motor, solenoid valve shall be measured and paid sepretely as supply only. 66 Supply only 500 GPD membrane suiltable for reserve osmosis (RO) plant of capacity 500 liters per hour, complete all as specified and directed 67 Supply only filter set suiltable for reserve osmosis (RO) plant of capacity 500 liters per hour complete all as specified and directed. 68 Supply only adopter suiltable for reserve osmosis (RO) plant of capacity 500 liters per hour, complete all as specified and directed. 69 Supply only solenoid suiltable for reserve osmosis (RO) plant of capacity 500 liters per hour complete all as specified and directed. 70 Repairs to industrial type RO plant of capacity 100 liters per hour of any type make by dismantling and carry out servicing and overhauling and making functional after throughly examine/checking all components, inlet and outlet piping system, descaling complete,pressure meter, auto flushing (solenoid valve), automatic ON/OFF, indicators and anti scalant dosing system etc and replacement of spare parts/components viz 100 GPD membrane, filter set, adoptor, motor, solenoid valve, and pipe coupling set and testing for its performance complete all as specified and directed.Note:-100 GPD membrane, filter set, adopter, motor, solenoid valve shall be measured and paid sepretely as supply only. Supply only 100 GPD membrane suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant, complete all as specified and directed 72 Supply only filter set suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant complete all as specified and directed. 73 Supply only adopter suiltable for reserve osmosis (RO) plant of capacity 100 liters per hour of existing make and model of RO plant, complete all as specified and directed. 74 Supply only solenoid suiltable for reserve osmosis (RO) plant of capacity 100 liters per hourof existing make and model of RO plant, complete all as specified and directed.
Contract Date: Feb 02, 2026 Contract Value : 10.99 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Jammu And Kashmir View Result →
49.
Heavy Industries and Public Enterprises #9039756 Technical Bid
Reversible Stacker Cum Reclaimer Package For Reversible Stacker Cum Reclaimer Package For 2X660 Mw Talcher Thermal Power Project Stage Iii , Supply Part Comprising Of Design (I.E. Preparation And Submission Of Drawing /Documents Including As Built Drawings And O&M Manuals), Design , Engineering, Manufacture, Fabrication, Assembly, Inspection & Testing At Vendors & Sub-Vendors Works, Painting, Maintenance Tools & Tackles, Mandatory Spares , Spares For Erection, Start-Up And Commissioning As Required, Fill Of Lubricants & Consumables And Till Cod Of The Units, Forwarding, Proper Packing, Shipment And Delivery At Site For Project And Package Complete With All Accessories For The Total Scope Defined As Per Bhel Nit & Tender Technical Specification, Amendment & Agreements Till Placement Of Order. , Completereversible Bucket Wheel Stacker Cum Reclaimer Machine With Accessories (Including Design, Engineering, Manufacturing, Inspection, Supply With Mechanical And Electrical And C&I Accessories As Per The Scope Mentioned In Technical Enquiry Specifications,Rails & Rail Fixture For Machine , Including Belting For Boom Conveyor, Belt Weigher, End Stops, Storm Anchors, Air Conditioning For Operator Cabins, All Electricals, Hydraulic Drives ( As Applicable ) , With Complete Accessories , All Electrical And C& I Items Required For Machine As Per Nit Specifications. , Machine Mounted Ds System Forreversible Bucket Wheel Stacker Cum Reclaimer Machine , Stockyard Management System Shall Be Provided Complying Completely With The Requirements As Per Nit Specification And C&I Annexure To Sub Section A-20, Part-B Consisting Of : A) 3D Coal Stockpile Mapping And Visualization B) Hotspot Detection System And Interfacing For Automatic Sprinkler Operation C) Readiness For Unmanned Operation Of Reversible Stacker & Reclaimer Machine D) Operating Modes For Reversible Stacker & Reclaimer Machine In Stockyard Management System E) Features Of Automatic Operation F) Cctv G) Interfacing With Other Systems And Packages At Site H) System Hardware I) Online Healthiness Monitoring Of Bearings & Gearboxes Of Reversible Stacker & Reclaimer Machine , Mandatory Spares As Per List Specified In The Specification. , Mechanical Mandatory Spares For Stacker Reclaimer Machine ( As Per Annexure-7) Note: 1 . : If Any Item Appearsin More Than One Place Same Shall Be Considered By The Bidder Irrespective Of Duplicity And Price Shall Be Considered Accordingly. Note2 : Bidder Shall Not Indicate Not Applicable Against Any Of The Spare (Except For Those Items For Which If Applicable Is Specified). In Case Of Not Applicability, Functionally Equivalent Spare To Be Mentioned With Price In The Relevant Price Schedules , Electrical And C& I Mandatory Spares For Stacker Machine ( As Per Annexure-7) Note: 1 . : If Any Item Appearsin More Than One Place Same Shall Be Considered By The Bidder Irrespective Of Duplicity And Price Shall Be Considered Accordingly. Note2 : Bidder Shall Not Indicate Not Applicable Against Any Of The Spare (Except For Those Items For Which If Applicable Is Specified). In Case Of Not Applicability, Functionally Equivalent Spare To Be Mentioned With Price In The Relevant Price Schedules , Installation Services, Erection & Commissioning, Pg Test, O&M, Amc , Installation Services Of Complete Reversible Bucket Wheel Stacker Cum Reclaimer Machine Including All Equipment/Sub-Systems As Per Scope Defined In Nit Specification Comprising Of Receipt, Unloading, Handling, Transportation & Storage At Site, Lifting/Shifting To Closed/Open Storage, In-Site Transportation, To Make Approach Road Wherever Required, Round The Clock Security At Open Storage Yard , Closed Storage Shed & Erected Material Till Completion Of Work, Assembly, Complete Erection, Alignment, Carrying Out Pre-Commissioning, Commissioning, Trial Run At Site And Carrying Out Performance Guarantee Tests, Reliability Test Run, Smart Project Management System ( As Defined In The Enquiry Specification) , Functional/Demonstration Tests At Site (As Applicable Obtaining Provisional Acceptance Certificate (Pac), Final Acceptance Certificate (Fac) And Handing Over Of Reversible Bucket Wheel Stacker Cum Reclaimer Machine Including Equipment & Sub-Systems ,Complete With All Accessories For The Total Scope Defined As Per Bhel Nit & Tender Technical Specification, Amendment & Agreements Till Placement Of Order. , Construction Of Temporary Open Storage Yard And Closed Storage Shed As Per Specfication For Storing The Items/ Sub-Assemblies Of Bucket Wheel Stacker Cum Reclaimer Machine Despacthed To Site. , Touch- Up Painting At Site After Erection. , Safety Training: After The Design And Installation Are Developed And Supervised By Qualified Engineers Familiar With Recognized Safety Features And Requirements, The Next Priority Should Be Personnel Training. Operating And Maintenance Personnel And Their Supervisors Should Be Initially And Then Periodically Retrained In Safe Operating Procedures, Recognizable Hazards, Precautions And The Maintenance Of A Safe Work Place. Accordingly, Contractor To Provide The List Of Proper Tools And Tackles To Operate And Maintain The Machine In An Adequately Safe Condition. Employees Should Be Made Aware Of, And Forbidden To Enter, Hazardous Areas. The Training Proposal By Contractor Must Include Safety Training Module For Site Personnel. , Training Module For Reversible Stacker Reclaimer Machine Comprising Following Aspect: The Successful Bidder Shall Conduct Training Of Engineers Of The Owner On Engineering, Operation And Maintenance Of The Machine At The Successful Bidders Or Associates Or Sub Vendors Premises Where Adequate Training Facilities Are Available During The Design And Manufacturing Stage Of The Successful Bidder. - Product Design - Basic Design Features - Theory & Principle Of Operation - Latest Technological Trends In Stacker Reclaimer Machines And Design Plant Visit - Plant Visit - Operational Feedback - O&M History/Problems Related To Stacker Reclaimer Machines - Visit To Manufacturer’S Work - Manufacturing Process Of Stacker Reclaimer Machines - Testing Facilities - Operation & Maintenance Of Stacker Reclaimer Machines - Trouble Shooting And Fault Analysis - Familiarization Of Special Maintenance Techniques - Special Tool And Tackles Familiarization - Stock Yard Management System , Operation & Maintenace Of Reversible Bucket Wheel Stacker Cum Reclaimer Machine( Shifts As Deifined In The Specification) , Comprehensive Annual Maintenance Contract:The Contractor Shall Provide Comprehensive Annual Maintenance Contract (Amc) For 3 Years After Completion Of Defect Liability Period (Warranty).This Shall Cover Total Maintenance Of Hardware & Software Related To Stockyard Management System & Shall Include Free Repair/Replacement Of All Components/Cables/Equipment Etc. In Case, Any Part Of The System/ Equipment Is To Be Taken Out For Servicing / Calibration Etc., Then Substitute Equipment / Device Shall Be Available At Plant Up To End Of Amc Period So That At No Stage Operation Of Stacker / Reclaimer Machine And Stockyard Management System Is Affected In Anyway. The Above Shall Also Include Provision Of Software Updates For Software & Database Servers Including Os Security Updates & Firmware Upgrades. During Amc Period, The Contractor’S Engineers Shall Reach Site Within 48 Hours Of Reporting Of The Complaint.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
50.
Defence #8947892 Technical Bid
Tender For Extension Of First Floord& E Building At Be -Hyd- Civil Works: 2 Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 3 Removal Of Surkhi Of Any Thickness By Manual Stock Mechanical Meanson The Terrace And Disposing The Debries Upto 50M Lead Etc Complete 4 Demolishing R.C.C. Work Manually / By Mechanical Means Including Tacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge. 5 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. In Cement Mortar 6 Disposal Of Moorum / Building Rubbish / Malba / Similar Unserviceable, Dismantled Or Waste Material By Mechanical Transport Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground For Lead Upto 10 Km For All Lifts, Complete As Per Directions Of Engineer-In-Charge. 7 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead : Of Area 3 Sq. Metres And Below 8 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge All Works Above Plinth Level Upto Floor V Level 9 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Columns, Pillars, Piers, Abutments, Posts And Struts 10 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 11 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform 12 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Weather Shade, Chajjas, Corbels Etc., Including Edges 13 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards 14 Steel Reinforcement Of Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. The Work Shall Be Executed As Per The Darwing Including All Heights. ( Note: The Basic Rate For Steel To Be Considered Is Rs55 Kg ) 15 Providing And Fixing 8 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :8 Mm Dia 16 Providing And Fixing 10 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :10 Mm Dia 17 Providing And Fixing 12 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :12 Mm Dia 18 Providing And Fixing16 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :16 Mm Dia 19 Providing And Fixing 20 Mm Rebar With Re-500 V 3 Chemical Etc. Including Drilling Hole As Required And Embedment Length As Per Specification Complete In All Repect As Per The Directions Of The Engineer Incharge :20 Mm Dia 20 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 5 In Superstructure Above Plinth Level Up To Floor V Level In Ll Shapes And Sizes In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 21 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 22 12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 23 6 Mm Cement Plaster Of Mix :1:3 ( 1 Cement : 3 Fine Sand ) 24 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade : New Work ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg / 10 Sqm ) 25 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade With A Coat Of Primer :Two Or More Coats On New Work 26 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 27 Providing And Painting Two Or More Coats On New Work With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade 28 Providing Sal Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) 29 Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embedding In Cement Concrete Block 30X10x15cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20Mm Nominal Size ) . 30 Providing And Fixing 35 Mm Thick Flush Door Confirming Is: 2202 ( Part-1 ) Core Of Solid Wood, Construction With Frame Of Pine Wood With Density Of 700 Kg / M3 With 5 Ply Construction With 1Mm Hpl Sheet ( Laminate ) On Both Sides And Laminate Pre Pressed From Factory, Confirming Is 2046 With Bwp Grade Adhesive Treatment With Phenol Formaldehyde Resin As Per Is 848 Norms Ensures Superior Quality And Performance Of The Doors With Uniform Thickness Without Undulation, Wraping Or Bending. Emission Free As Per E1 Standard And Eco-Friendly Fixed To The Existing Frames Including Providing Internal Lipping With Second Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Shutter With 4 Nos.Of 125Mm Long Ss Hinges For One Shutter Etc., Complete. ( Note: The Shutters Shall Be Provided With Vision Pannel As Per Drawing. In Case Of Double Leaved Shutters Rebating Shall Be Made Without Any Extra Cost ) 31 Providing And Fixing Bright / Matt Finished Stainless Steel Handles Of22 Dia X 200Mm, Godrej Code No 7261 Or Approved Quality & Make With Necessary Screws Etc All Complete. 32 Providing And Fixing Stainless Steel ( 304 Grade ) Satin Finishtower Bolt 300 Mm Long Of Godrej Make ( Product Code - 8570 ) Or Equivalent With Necessary Screws Etc., Complete 33 Providing And Fixing Stainless Steel ( 304 Grade ) Satin Finish Door Stopper 90 Mm Longof Godrej Make ( Product Code - 8565 ) Or Equivalent With Necessary Screws Etc., Complete 34 Providing And Fixing Standard Approved Quality Hydraulic Door Closers Suitable For Doorsof Dorma Make With Necessary Fixtures, Screws Etc. Complete. 35 Providing And Fixing Bright Finished Inside Opening Brass Mortice Lock With 6 Levers Of Godrej Make Or Equivalent With Necessary Screws Etc., Complete 36 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coatwith Approved Steel Primer All Complete Fixed To Steel Windows By Welding 37 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) : For Fixed Portion Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 38 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) :For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) 39 Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is: 12823 Grade L Type Ll, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineerin- Charge. Pre-Laminated Particle Board With Decorative Laminationn On Both Sides 40 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 4.0 Mm Thickness ( Weight Not Less Than 10Kg / Sqm ) 41 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 5.50 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) 42 Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels.Granite Of Any Colour And Shade Area Of Slab Upto 0.50 Sqm 43 Providing And Laying Vitrified Tiles In Floor With Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is:15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tile 600X600 Mm ( Basic Price Of Vitrified Tile Is Rs 660.00 Per Sqm 44 Providing And Laying Vitrified Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, In Skirting, Riser Of Steps, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is: 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tile 600X600 Mm 45 Supply And Laying Of Electrostatic Dissipative Type Flexible Homogenous Compressed Esd Vinyl Floor Tiles Of Minimum Size 610 Mm X 610 Mm X 2 Mm Of M / S Forbo Make. Necessary Preparation Of Sub Floor Surface Should Be Bel - Quotation For The Esd Flooring-Reg Done Using Self-Leveling Compound. The Flooring Should Be Laid Using Approved Conductive Adhesives. Joint Between The Tiles Shall Be Grooved, Pvc Welded Using Automatic Equipment And Copper Tape Shall Be Provided And Laid All As Per Manufacturer’S Specification. The Tiles Will Have Permanent Conductivity And Esd Properties To Be Independent Of Humidity Due To Homogenous Nature Of Product As It Is Sliced From Pressed Vinyl Block. Scope Of Work Should Include Laying Of Tiles, Self Levelling Compound, Conductive Adhesive, Copper Tape At Site, Grooving / Welding Of Joints As Per Manufacturers Specifications. Certification Of Electrical Resistance Such As Point To Point, Point To Ground And Body To Ground Resistance, Combination Resistance Of The Installed System And Body Voltage Generation, Meeting To International Standards And Duly Tested And Authorized By A Certified Esd Engineer Who Has Received His Certificate From An Internationally Reputed Certifying Organization. ( Note: Rate To Be Quoted For Complete Finished Work Including All Materials And Labour And Necessary Preparation Of Surface. 46 Providing And Fixing In False Ceilingat All Height With Integral Densified Calcium Silicate Reinforced With Fibre And Natural Filler False Ceiling Tiles Of Size 595X595 Mm Of Approved Texture, Design And Patterns Having Nrc ( Noise Reduction Coefficient ) Of 0.50 ( Minimum ) As Per Is 8225:1987, Light Reflecting Of 85% ( Minimum ) .Non Combustible As Per Bs:476 ( Part-4 ) , Fireperformance As Per Bs:476 ( Part 6 &7 ) , Humidity Resistance Of 100%, Thermal Conductivity <0.043W / M K As Per Astm / 518:1991, In True Horizontal Level Suspended On Interlocking Metal Coated T-Grid Of Hot Dipped Galvanised Iron Section Of 0.40 Mm Thick On Silhouette Profile, Rotatory Stiched Double Webbed White With 6 Mm Reveal Profile ( White / Black ) , Comprising Of Main-T Runners Of Size 15X42 Mm Of Length 3000 Mm, Cross -T Of Size 15X42 Mm Of Length 600Mm To Form Grid Module Of Size 600X600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items ( Galvanizing @80 Grams Per Sqm ) I.E 50 Mm Long, 8Mm Outer Diameter M-6 Dash Fasteners , 4Mm Thick G I Hanger, With 15 Mm Thick Integral Densified Micro Edge Light Weight Calcium Silicate False Ceiling Tiles. 47 Providing And Fixing Seamless Ceiling With Gpboard Of 12.5Mm Thick , Fixed To The Underside Of The Suspended Grid Formed Of Gi Perimeter Channel Of Size 20X27x30 Mm ( Mf 6A ) Fixed Along The Wall By Using Wood Screws And Metal Expansion Rawl Plugs. The Gi Intermediate Channel Of Size 45X15x0.90 Mm ( Mf7 ) Shall Be Fixed To The Suspended Strap Hangers / Gi Angle / Starp Hanger Is To Be Connecte With Gi Soffit Cleat Of Size 37X27x25x1.6 Mm And It Should Be Fixed On The Roof Slab / Beam, By Using Metal Expansion Fasteners ( Wt. Type ) Of 12.5 Mm Dia. To A Length Of 35 Mm With 6 Mm Dia Bolt / Screw At Top Ends. The Gi Ceiling Section Of Size 80X26x0.5 Mm ( Mf 5 ) Is To Be Provided Across The Intermediate Channel At Intervals Not More Than 610 Mm Centre At Bottom And The Same Shall Be Fixed By Gi Connection Clips 2.64 Mm Dia At The Intersection Points . The Ends Of Ceiling Section ( Mf 5 ) Channel By Adopting An Overlap Length Of Minimum 150 Mm, Shall Be Connected With Intermediate Channel Perimeter Channel In Insertion The Gypboard Shall Be Fixed To The Under Side Of The Suspended Grid By Using 25 Mm Long Dry Wall Screws. The Joints Shall Be Finished With Joint Paper / Fibre Mesh Lape By Using Jointing Compound Of Saint-Gobain Ltd., And Applying Over It 3 Layers Of The Filer Compound To Provide A Smooth Surface. The Rate Shall Include Making Cutouts For Tube Lights, Spot Light , Duct Doors, For Specified Size, Grills Etc., For Which No Extra Wil Be Paid Separately. Rate Shall Include Providing Additionaltrimming Around Cutouts For Light Fittings Grills And Also For Providing Additional Supports From Ceiling Wheremain / Cross Members Are Cut For Light Fittings Etc. This False Ceiling Shall Be Provided In Combination Of 600X600 Calcium Silicate False Ceiling And Will Be Measured Under Respective Item. 48 52 Mm Thick Cement Concrete Flooring With Concrete Hardener Topping, Under Layer 40 Mm Thick Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) And Top Layer 12 Mm Thick Cement Hardener Consisting Of Mix 1:2 ( 1 Cement Hardener Mix : 2 Graded Stone Aggregate 6 Mm Nominal Size ) By Volume, Hardening Compound Mixed @ 2 Litre Per 50 Kg Of Cement Or As Per ManufacturerS Specifications. This Includes Cost Of Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 49 Providing And Laying Integral Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: ( A ) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rccslab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. ( B ) Laying Brick Bats With Mortar Using Broken Bricks / Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 ( 1 Cement : 5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 ( 1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs. ( C ) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge. ( D ) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 ( 1 Cement :4 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineerin- Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. ( E ) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test.“All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. 50 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes. 110 Mm Diameter 51 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion Shoe ( Plain ) 110 Mm Shoe 52 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion Bend 87.5° 110 Mm Bend 53 Providing And Fixing Luxaflex Make 100 Mm Wide Vertical Blinds Made Out Of 100 Mm Non-Woven Fabric. The Fabric Shall Be Scotch Guard Protected, Antistatic And Shall Be Sanitized To Resist Fungal Growth. The Head Channel Shall Be Of 33 Mm Wide And 30 Mm Deep With A Minimum Valve Thickness Of 1.2 Mm Extruded From 6063-T5 Aluminium Alloy Finished In Clear Anodising To A Thickness Of 10 Microns ( Note: Height Of The Blind Will Be Measured From Top Of The Head Rail To Bottom Of Slat. Length Of The Head Rail Shall Be Measured To The Length Of The Blind ) Etc., Complete. 54 Electrical Works: 55 Supplying Of Lt Power Cable With Aluminium Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 3.5 Core Of Size 150 Sq Mm 56 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Above 95 Sq. Mm And Upto 185 Sq. Mm Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. 57 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 3½ X 150 Sq. Mm ( 50Mm ) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 58 Design, Fabrication, Supply, Erection, Testing And Commissioning Of Duly Wired 415Volts, 50Hz, 3Phase, 4Wire Electrical Main Distribution Board ( Mdb ) Having I / C& O / G Feeders, Instrumentation Metering, Protection System, Aluminium Busbars & Other Components Completely As Per Single Line Diagram And As Per Detailed Technical Specifications. The Panel Shall Be Of Modular Type, Floor Mounting, Free Standing, Vermin Proof, Ip-43 Grade, Made Out Of Crca Sheet Steel Of 1.6Mm Thickness For Body & 2Mm For Load Bearing Points, Powder Coated Painting, Fuseless Type Confirming To Relevent Is Standards. The Panel Shall Have Microprocessor Based Mccb With Shunt Tripp For Incomer And Thermal Magnetic Based Mccbs For Out Going Feeders With Rotory Handle. The Work Includes Providing Required Fixing Accessories Such As Grouting Bolt-Nuts, Welding, Coupling Of Laid Conduits / Cables And Associated Civil Works Complete As Directed. ( Note:- Please Refer Drawing And Dts For Mdb Details ) 59 Supplying Of Lt Power Cable With Copper Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 4 Core Of Size 16 Sq Mm 60 Supplying Of Lt Power Cable With Copper Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 4 Core Of Size 10 Sq Mm 61 Supplying Of Lt Power Cable With Aluminium Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 3.5 Core Of Size 50 Sq Mm 62 Supplying Of Lt Power Cable With Copper Conductor, Xlpe / Pvc Insulated, Pvc Inner Sheathed, Armoured, 1.1Kv Grade, Confirming To Is:1554 ( Part-1 ) , Is:7098 ( Part-1 ) & Relevant Standards Having 3 Core Of Size 10 Sq Mm 63 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. 64 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) Size On Cable Tray As Required. 65 Supplying And Fixing Of 6 Way ( 8+18 ) , Vtpn, ( Ip 43 ) , Metal Door, Sheet Steel, Mccb Distribution Board, 240 / 415 V, On Surface / Flush, Complete With Tinned Copper Bus Bar Of 250A, 2 Neutral Bus Bar, 2 Earthbar, Din Bar, Interconnections, Powder Painted Including Earthing And With Provison FormccbSas Incomer And Sp / Tp McbS As Outgoing. Ref:- Legrand -5077 46 66 Supplying And Fixing Of 12 Way , Double Door, ( Single Pole And Neutral ) , Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earthbar, Din Bar, Interconnections, Powder Painted Includingearthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) . 67 Supplying And Fixing Of6 Way ( 4 + 18 ) , Double Door , Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) . 68 Providing And Fixing Of 125A, 16Ka Of Breaking Capacity And Tpn Mccbwith Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. Ref:- Legrand -4200 06 69 Providing And Fixing Of 63A, 16Ka Of Breaking Capacity And Tpn Mccbwith Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. Ref:- Legrand -4200 00 To 4200 05 70 Providing And Fixing Of 100A, 16Ka Of Breaking Capacity And Tpn Mccbwith Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. Ref:- Legrand -4200 00 To 4200 05 71 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Double Pole, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required. 72 Supplying And Fixing Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required & As Per Sld. 73 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Triple Pole And Neutral Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required. 74 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Single Pole, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required. 75 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Triple Pole, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete Withconnections, Testing And Commissioning Etc. As Required. 76 Supplying And Fixing Of20 Mmsize Of Steel Conduit On The Wall / Column / Ceiling / Truss As The Case May Be Along With Accessoriesas Surface / Recess System Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit Including Associated Civil Works As Required. 77 Supplying And Fixing Of25 Mmsize Of Steel Conduit On The Wall / Column / Ceiling / Truss As The Case May Be Along With Accessoriesas Surface / Recess System Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit Including Associated Civil Works As Required. 78 Supplying And Fixing Of 20 Mm Size Of Medium Class Pvc Conduit Along With Accessories On The Wall / Column / Ceiling / Truss As Surface / Recess System Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit Including Associated Civil Works As Required. 79 Supplying And Fixing Of 25 Mm Size Of Medium Class Pvc Conduit Along With Accessories On The Wall / Column / Ceiling / Truss As Surface / Recess System Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduitwith Associated Civil Works As Required. 80 Supplying And Drawing / Wiring Of 3 X 1.5 Sq.Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 81 Supplying And Drawing / Wiring Of 3 X 2.5 Sq.Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 82 Supplying And Drawing / Wiring Of 3 X 4 Sq.Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 83 Supplying And Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Including Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group-C 84 Supplying And Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group-C 85 Supplying Of Below Mentioned Specification Led Luminaire & Fixing Of The Same In The Ceiling By Providing Required Down Rod / Chain, Clamps Screws / Anchor Bolt-Nuts, Washers Etc., Making Electrical Connections, Earthing Etc., As Required / Directed By Engineer-In-Charge. Mounting Type :- Recesstype :- 2Ft*2Ft Luminairesystem Lumens :- Not Less Than 3600 Lumensluminous Efficacy :- Not Less Than 100 Lumens / Wattinput Power :- Consuming Not More Than 36Wcolor Temperature :-Not Less Than 5700Khousing :- Pressure Die Cast Alluminium / Crcadiffuser :- Specially Frosted Polycarbonate Diffuserdriver :- Electronicref Model :-Wipro Enterprises :- Elate Led - Crco10r038hp57gl1 Or Equivalent In Approved Makes 86 Supplying Of Below Mentioned Specification Led Luminaire & Fixing Of The Same In The Ceiling By Providing Required, Clamps Screws / Anchor Bolt-Nuts, Washers Etc., Making Electrical Connections, Earthing Etc., As Required / Directed By Engineer-In-Chargetype :- Ip-65, Wetherproof, Industrial Type Linear Led Tube Light Luminaire With Capsule.Mounting Type: Surface Mounting Type. System Lumens :- Not Less Than 1800 Lumensrated Power :- Not More Than 20Wcolor Temperature :-Not Less Than 6000Khousing :- Extruded Powder Coated Aluminium / Polycorbonate Housing.Diffuser :- Polycorbonate Diffuser Coverdriver :- In Built Electronic Driver .Ref Model :- Similar To Wipro : Wio831208g1 Or Equivalent Approved Makes. 87 Supplying Of Below Mentioned Specification Led Luminaire & Fixing Of The Same In The Ceiling By Providing Required, Clamps Screws / Anchor Bolt-Nuts, Washers Etc., Making Electrical Connections, Earthing Etc., As Required / Directed By Engineer-In-Chargemounting Type :- Surface Mountingtype :- Round Down Light Luminaire.System Lumens :- Not Less Than 1800 Lumensrated Power :- Not More Than 18Wcolor Temperature :-Not Less Than 6000Khousing :- Powder Coated Pressure Die Cast Alluminium & Bottom Frame.Diffuser :- High Efficiency, Non Yellowing Pmma Diffuser.Driver :- Electronic Driver.Ref Model :- Wipro: Ld06-221Xxx-57Smg1 Or Equivalent In Approved Makes List. 88 Supplying And Fixing Ofmodular 5A / 6A Switch On The Existing Modular Plate & Switch Box Including Making Electricalconnections But Excluding Modular Plate Etc. As Required. 89 Supplying And Fixing Of Modular 15A / 16A Sp Switch On The Existing Modular Plate & Switch Box Including Making Electricalconnections But Excluding Modular Plate Etc. As Required. 90 Supplying And Fixing Of Modular3pin 5A / 6A Socket Outleton The Existing Modular Plate & Switch Box Including Making Electricalconnections But Excluding Modular Plate Etc. As Required. 91 Supplying And Fixing Of Modular 6Pin 15A / 16A Socket Outlet On The Existing Modular Plate & Switch Box Including Making Electricalconnections But Excluding Modular Plate Etc. As Required. 92 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 93 Supplying & Fixingof2 Timer Acdb Comprising Of 7X24hrs Microcontroller Based Programmable 2 Change Over Time Switch ( Digital, Daily / Weekly Program, 6 Years Reserve, 230Vac With Lethium Cell ) , 25A 3Pole Power Contactor, Terminal Blocks, Wire Etc., For Automatic Switching On & Off Of The 3Nos Ac Systems Alternatively 2Nos Ac Units At A Time For 8Hrs, The Switchgears Shall Be Completly Housed / Mounted In Suitable Size Indoor Duty Non Metallic / Crca Box And Installation Of The Same Recessed / Partly Recessed In Wall By Providing Fixing Accessories Such As Bolt-Nuts, Clamps, Screws, Welding Etc., Coupling Of The Laid Conduits / Cables, Making Electrical Connections Etc., Including Associated Civil Works Complete As Directed. ( Ref Make For Time Switch: Schneider Time Switch ( Cct15720 ) Or Equivalent In Approved Make ) ( Please Refer Our Electrical Drawings & Dts For Details ) . 94 Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 95 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For3½ X 50 Sq. Mm ( 35Mm ) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 96 Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For 4 X 10 Sq. Mm Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 97 Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For 4 X 16 Sq. Mm Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 98 Supplying And Making End Termination With Brass Compression Gland And Copper Lugs For 3 X 10 Sq. Mm Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 99 Supplying And Fixing Of 4 Way ( 8+12 ) , Vtpn, ( Ip 30 ) , Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Flush, Complete With Tinned Copper Bus Bar Of 250A, 2 Neutral Bus Bar, 2 Earthbar, Din Bar, Interconnections, Powder Painted Including Earthing And With Provison FormccbSas Incomer And Sp / Tp McbS As Outgoing. 100 Supplying And Fixing Of1 Or 2 ( 75Mm X 75Mm ) Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recessincluding Associated Civil Works Etc., As Required. 101 Supplying And Fixing Of 4 Module ( 100Mm X 75Mm ) , Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recessincluding Associated Civil Works Etc., As Required. 102 Supplying And Fixingof6 Module ( 200Mm X 75Mm ) Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recessincluding Associated Civil Works Etc., As Required. 103 Supplying And Fixing Of 12 Module ( 200Mm X 150Mm ) Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recessincluding Associated Civil Works Etc., As Required. 104 Supplying And Laying 25 Mm X 5 Mm Copper Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of Brass Nut Bolt & Spring Washer Spaced At 50Mm ) 105 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm ) 106 Supplying And Installing300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 107 Supplying And Installing300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Bends ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc.As Required. 108 Supplying And Installing 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Size Of Perforated Hot Dipped Galvanised Iron Cable Tray Tee ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 109 Supplying Of All The Required Materials Of Approved Make To Construct A Maintenance Free Chemical Earthing System As Per Drawing & Detailed Specification. Each Set Of Earthing Pit Shall Consists Of A Copper Bonded Solid Steel Rod Electrode Of 14.0Mm Dia X 3.0Mtr Length With Required Quantity Of Nontoxic Electrically Conductive Concrete / Backfill Compound, Copper / Brass Termination Busbar & Bolt-Nuts, Washers Etc. The Work Includes Drilling / Making A Hole Of 150Mm Dia In The Ground To Required Depth By Manual Or Mechanized Method, Keeping The Electrode In The Centre Of The Pit, Filling The Already Prepared Semi Solid Paste / Slurry Of Backfill Concrete / Compound Fully & Curing, All The Civil Works Such As Excavation, Refilling, Construction Of Brick Chamber, Rcc Cover, Curring Etc. The Complete Work Shall Be Carried Out As Per Our Drawing And Manufacturers Instructions / Mannuals Or As Per Standard. Note: The Earth Enhancing Compound / Concrete Shall Be Of Low Resistivity Conforming To Iec 62561-7 Standard. ( Makes: Obo / Erico / Loress / Indelec / Jmv / Lpi / Ashlok ) 110 Supplying & Fixing Of Ip-44 Grade Non Metalic Distribution Box Having 32A, 3Pole+N+Earth Insulated Plug & Socket ( With Plug Top ) , 32Atpn Mcb ( 10Ka, C-Curve ) Along With Accessories And Fixing Of The Same As On The Wall Orflush With Wall As Required Coupling Of The Condiuts, Making Electrical Connections, Earthing Etc., As Directed ( Ref Make:Legrand:0566 53 ) Or Equivalent From Approved Makes. 111 Supplying & Fixing Of Ip-65 Grade Non Metalic Distribution Box Having 32A, 3Pole+N+Earth Insulated Plug & Socket ( With Plug Top ) , 32Atpn Mcb ( 10Ka, C-Curve ) Along With Accessories And Fixing Of The Same As On The Wall Orflush With Wall As Required Coupling Of The Condiuts, Making Electrical Connections, Earthing Etc., As Directed ( Ref Make: Legrand:0566 73 ) Or Equivalent From Approved Makes. 112 Supplying, Installation, Testing And Commissioning Of Passive Infrared ( Pir ) Technology Based Occupancy Sensor With Day Light Dimming ( Lighting Level Shall Be Regulated As Per Availability Of Natural Day Light In An Area Along With Occupancy Detection. ) Having High Preformance, Regulating Programmable Type, Suitable For Connected Load Upto 10Amp , For Mounting Height Up To 2.8 Mtr And For 5 M Diameter Coverage Area Along With Necessary Fixing Arrangements I / C Programming At Site Etc. Complete As Required. 113 Fas & Pas 114 Supply, Installation, Testing And Commissioning Of Microprocessor Controlled Four / Five Loop Analogue Addressable Main Fire Alarm Control Panel With Five ( 5 ) Loop Cards, Alarm Facilities, Hooter, Fire / Fault Indications, Audio Visual Signals, Batterycharger, Facility To Connect Printer Through Extra Rs485 Module And Public Address System Interface System Software.Make: Morley 115 Supply, Installation, Testing And Commissioning Of Addressable Uniform Flat Response / Multi Sensor Type Smoke Sensor With Base.Make: Morley-Ias 116 Supply, Installation, Testing And Commissioning Of Addressable Manual Call Point / Station With Modules.Make: Morley-Ias 117 Supply, Installation, Testing And Commissioning Of Response Indicator.Make: Locally Manufactured 118 Supply, Erection, Testing And Commissioning Of Addressable Wall / Ceiling Loop Sounder / Hooter.Make: Morley-Ias 119 Supply, Installation, Testing And Commissioning Of 2C X 1.5 Sq.Mm Pvc Armoured Frls Copper Cable Including Juction Boxes All As Specified And / Or Directed Etc., Complete. 120 Supplying Of Single Sided Exit Signage Led Light Of Red / Green Colour As Required At Site With Built In Battery Backup For 2 Hrsand Fixing Of The Same On The Rcc / False Ceiling By Providing Required Clamps / Downrods / Bolt-Nuts / Screws, Making Electrical Connections Etc., As Required / Directed By Engineer-In-Charge. Please Refer Fire Alarm System Drawing For Locations. ( Make Similar To Bajaj Or Equivalent In Other Makes ) 121 Supply, Erection, Testing And Commissioning Of 6W Ceiling Mounted Speakers With Builtin 100 V Line Transformers And Different Power Tapping All Asspecified And / Or Directedetc., Complete. 122 Supply, Erection, Testing And Commissioning Of 6W Wall Mounted Speakers With Builtin 100 V Line Transformers And Different Power Tapping All Asspecified And / Or Directedetc., Complete. 123 Supply, Erection, Testing And Commissioning Of Volume Control Switch All As Specifiedand / Ordirectedetc., Complete. 124 Supply And Laying Of 2 Core ( 24 / 0.2 ) Copper Wire Pvc Insulated Twisted And Shielded Unarmoured Wire For Speakers / Volume Control Switch Of Public Address System Suitable For Laying In Pvc Conduit All As Specified And / Or Required Etc Complete., 125 Supply And Fixing 19 Mm Dia 2 Mm Thick Pvc Conduit Along With All Accessories Likebends, Elbows, Jbs, Tees., In Surface / Recess Including Chipping The Wall Making Good The Same In Case Of Recessed Conduit All As Specified And / Or Required And Directed. 126 Supply, Erection, Testing And Commissioning Of Zone Selector Of Capacity Not Less Than 4 Zone With Console With A Mic For Pa System. 127 Network And Communication 128 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required..23 Awg Solid Bare Copper , Flame Retardant Pvc Jacket, In A Box Of 305M, And Iso / Iec 11801Iec61156•5 Complaint Make: Comscope / Panduit-Pannet / Dlink / Belden 129 Supplying And Laying Of Following Size Of Hdpe Pipe 63Mm Od .Lsi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc. In The Existing Trench, Complete As Required. 63 Mm Hdpe Pipe In Duct / Trench As Directed By Engineer Incharge .Make:Prime / Reliance / Apollo / Rishi 130 Supplying And Fixing Of Following Sizes Of Medium Class 25 Mm Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.E.Make: Universal / Supreme / Classic 131 Supplying And Fixing Of Following Sizes Of Medium Class 50 Mm Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.Make: Universal / Supreme / Classic 132 Supplying, Installation, Termination, Labling & Testing Of Dual ( 2 ) Port Flush Type Face Plate With Back Box.Cat6.Make: Comscope / Panduit-Pannet / Dlink / Belden 133 Supplying, Installation, Termination, Labling& Testing Of Rj-45 Modular Jacks, Complaint With Isollec11801 Nsi / Tia / Eia-568, Should Accept Solid 22-24 Awg Diameter Conductors With Certified For Ul94v-0 Rated, Series Connecting Hardware Standards .Cat6 ( Green Or Yellow ) . Make: Comscope / Panduit-Pannet / Dlink / Belden 134 Supplying, Installation, Termination, Testing, Commissioning And Labling Of 24-Port Patch Panel, Utp Category 6, Tia / Eia 568-6.2, With Min1000 Mating Cycles, Metal Rear Cable Manager To Properly Guide Cables To Point Of Termination And Come With Velcro Straps For Tying The Cables, Modular Connector Should Be Fcc Part68, Subpart F And Iec-60603-7 Allows For 568 A / B Wiring Configuration And Idc Body & Cover Material Fire - Retardant Make: Comscope / Panduit-Pannet / Dlink / Belden 135 Supplying, Laying, Labling& Testing Of Utp Category 6 Patch Cords 2 Mtrs, Tia / Eia 568-8.2 , With Lsoh - Low Smoke Zero Halogen Free. And 1000 Mating Cycles, Rj 45 Plug Should Be Of Polycarbonate Fcc Part 68 Subpart F, Ul 94V-0Make: Comscope / Panduit-Pannet / Dlink / Belden 136 Supplying, Laying, Labling& Testing Of Utp Category 6 Patch Cords 1 Mtrs, Tia / Eia 568-8.2 , With Lsoh - Low Smoke Zero Halogen Free. And 1000 Mating Cycles, Rj 45 Plug Should Be Of Polycarbonate Fcc Part 68 Subpart F, Ul 94V-0Make: Comscope / Panduit-Pannet / Dlink / Belden 137 Supplying And Laying Of 150 X 50 Mm Gi Cable Raceways With Top Press Cover And 10 Mm Threading Rods Clamps Without Powder Coat. 138 Supplying, Installation, Cabling, And Labeling Of 19”, 42 U800 X 800Network Rack –With Cutouts For Cable Entry. Color: Black / Gray1 ) Front Perforated Single Door- 1NoS 2 ) 230V Ac Fan Assy Fully Wired - 1 Set 3 ) 1U Pvc Horizontal Cable Manager – 12 NoS 4 ) Pvc Vertical Cable Organisers – 2 NoS5 ) Vertical Pdu, 5 / 15A, Socket Strip With Min 12 Sockets With Indicators With 3 Mtr Power Chord With 16A Plug –1 NoS6 ) With Required Fitting Accessories Including Lock And Key. Make :Apw President / Rittal / Netrack 139 Supplying, Installation, Configuration And Testingof Data Switch With 24-Port 100 / 1000 Mbps Rj45 Ports Switch With Min Of 2 X1gb / 10 Gb Sfp / Sfp+ Interface Ports, Switching Capacity128 Gbps ( Stacking Bw Of 40Gbps ) Or Higher, Ram 512Mb Or Higher , Stacking Bw 40 Gbps Or Higher Including Stacking Cable And Etc, Including Power Supply, Fan, Ipv6 Certified Logo, Oem Warranty Of 1 Year And Service Contracts For 1 Year And Oem Authorizationmake :Cisco / Hp / Extreme / Juniper / Dlink 140 Supplying, Installation, Configuration And Testingof Data Switch With Poe24-Port 100 / 1000 Mbps Rj45 Ports Switch With Min Of 2 X1gb / 10 Gb Sfp / Sfp+ Interface Ports, Switching Capacity128 Gbps ( Stacking Bw Of 40Gbps ) Or Higher, Ram 512Mb Or Higher , Power Supply Of 370W , Stacking Bw 40 Gbps Or Higher Including Stacking Cable Etc, Including Power Supply, Fan, Ipv6 Certified Logo, Oem Warranty Of 1 Year And Service Contracts For 1 Year And Oem Authorizationmake :Cisco / Hp / Extreme / Juniper / Dlink 141 Supplying, Installation, Configuration And Testingof 1000 Base Sfp Opticaltransceiver Module For Single Mode Fiber , 1310-Nm Wavelength, Compatible With The Ieee 802.3Z , Dual Lc Connector With Speed On 1Gbps, Sfp Optical Transceivers Should Support Above Switch Modules Of Bom, Switch And Sfp Modules Should Be Of Same Makes.Oem Warranty Of 1 Year Make :Cisco / Hp / Extreme / Juniper / Dlink. 142 Air Conditioning Works 143 Supply, Installation, Testing And Commissioning Of Factory Built Floor Mounted Cabinet Type Horizontal / Vertical Double Skin Type Air Handling Unit ( Ahu ) For Of Capacitynot Less Than 22 Tr, Total Dehumidified Cfm 8800, 35Mm Esp Complete With Didw Backward Curved Centrifugal Fan With Vfd Compatible Motor, Motor Class- Ie2, Mixing Box With Provision For Connecting Return Air And Fresh Air With Damper, Provision For Electric Strip Heater, Internal Power / Control Cabling, Belt Drive System, Spring Type Isolation System ( Min. Vibration Isolation Efficiency 90% ) , Pre Filters With 90% Efficiency Down To 10 Μm ( Eu -4 ) , Fine Filters With 95% Efficiency Down To 5 Μm, Dx Cooling Coil 6 Rows Deep Of Copper Tubes With Aluminium Fins Suitable For Working With Dx Condensing Outdoor Unit, Min.1.2 Mm Thick Ss-304 Drain Pan With 13 Mm Nitrile Rubber Insulation, Fire Proof Flexible Connection At Outlet. Ahu Outerskin Shall Be 0.8Mm Pre-Coated Gss, Inner Skin Shall Be 0.8 Mm Plain Gi With Thermal Break Profile. Panels Shall Be 43± 2 Thick With Puf Injected With Density Not Less Than 38Kg / M3. The Quoted Price Shall Include The Price Of Necessary Control Wiring And Necessary Control Wiring And Necessary Kit For Interlocking Fan Shall Be Considered. Note:1 ) The Capacity Indicated Above Is For Reference Only, The Contractor Shall Design And Indicate The Actual Size, If Higher Size Units Are Required.2 ) The Pcc Pedestal / Bed Provided For Installation Of Ahu Will Be Measured And Paid Under The Relevant Item Of Soqr. 3 ) The Rate To Be Quoted For The Ahu Shall Be Excluding The Cost Of Ms Frame / Brackets / Supports. Thems Frame / Brackets / Supports Will Be Measured And Paid Separately Under The Relevant Item Of Soqr. 144 Supply, Erection, Testing And Commissioning Of Air Cooled Condensing ( Outdoor ) Unit Of Capacity Not Less Than 22 Tr ( 11Trx 2Nos Modules ) Suitable For Dx Air Handling Unit Mentioned In Item No. 1 Of Soqrcomplete With Scroll Compressor, R407c / R410a Refrigerant Gas, Thermostatic Expansion Valves, Condenser Coil With Suitable Size Fan & Motor, All Necessary Controls / Protection Viz., Thermostat, Hp / Lp Cut Out, Microprocessor Based Control Unit Including Necessary Power And Contol Wiring Between Air Handling Unit And Condensing Units, All As Specified And / Or Directed Etc., Complete. Note: 1 ) The Pcc Pedestal / Bed / Ms Frame / Brackets / Supports Provided For Installation Of Condensing Unit Will Be Measured And Paid Under The Relevant Item Of Soqr. 145 Supply, Erection, Testing And Commissioning Of Suitable Size Refrigerant Grade Copper Piping Between Dx Ahu ( Soqr No. 1 ) And 22 Tr Outdoor Condensing Unit ( Soqr No. 2 ) For Suction, Liquid And Discharge Lines Including All Fittings, Accessories, Tube Type Nitrile Rubber Insulation With Frp / Glass Cloth Rapped Over Insulation From Indoor To Outdoor Unit With Uv Resistant Paint Orclosed Cell Physically Crosslinked Polyolefin Foam With Frp / Glass Cloth Rapped Over Insulation With Uv Resistant Paint ( For Both Suction And Liquid Line ) , Anti Corrosive Paint Suitable For Exposed Joints, Sleeve ( Wall Crossing ) , Supports, Core Cutting In Brick / Concrete Wall As Required And Making Surface Good, Etc., All As Specified And / Or Directed Etc., Complete. Note: Both Suction And Liquid Piping Will Be Treated As One Unit And Will Not Be Measured Separately. Also Irrespective Of Number Of Pipes / Circuits The Measurement Of Pipes Will Be Made Only Once Between 22 Tr Capacity Condensing Unit ( Soqr No. 2 ) And Ahu ( Soqr No. 1 ) . 146 Supply, Erection, Testing And Commissioning Of Cassette Ac ( Four Way ) Of Cooling Capacity Not Less Than 3Tr, Inverter Type Rotary / Scroll Compressor, Aircooled Condensing Unit With Copper Cooling Coil, Fan Motor And Indoor Unit Complete With Filter Section, Cooling Coil Of Copper Tubes With Aluminium Fins, Electric Motor, Fans Includinginitial Charge Of R410a / R32 Refrigerant And Subsequent Charge / Tapping Of Refrigerant During Testing / Commissioning If Any, Etc. As Required, Including Minor Civil Works Like Core Cutting, Msstand / Supports For Ac Units All As Specified And / Or Directed Etc., Complete.Quoted Price Shall Include Cost Of Wireless Remote Controller, Cooling Thermostat, Required Length Of Power Cable With Plug Top And Control Cable Between Indoor And Outdoor Units, Earthing. Unit Shall Be Provided With Auto Clean Mode, Auto Timer Setting And As Per Specifications. 147 Supply, Erection, Testing And Commissioning Of High Wall Mount Type Split Ac Units Of 1.5 Tr Capacity, Minimum 5 Star Rating Inverter Type Rotary / Scroll Compressor, Aircooled Condensing Unit With Copper Cooling Coil, Fan Motor And Indoor Unit Complete With Filter Section, Cooling Coil Of Copper Tubes With Aluminium Fins, With Anti Corrosive Paint Suitable For Coastal Application, Electric Motor, Fans Includinginitial Charge Of R410a / R32 Refrigerant And Subsequent Charge / Tapping Of Refrigerant During Testing / Commissioning If Any, Etc. As Required, Including Minor Civil Works Like Core Cutting All As Specified And / Or Directed Etc., Complete. Quoted Price Shall Include Cost Of Wireless Remote Controller, Cooling Thermostat, Wiring, Control Cabling And Earthing. Unit Shall Be Provided With Auto Clean Mode, Auto Timer Setting And As Per Specifications. 148 Providing Ms Frame For Split Ac Outdoor Condensing Unit Including Painting With Two Coats Of Synthetic Enamel Paint Of Approved Make And Shade, Over A Coat Of Approved Steel Primer Etc., Complete 149 Supply, Erection, Testing And Commissioning Of Refrigerant Grade Copper Piping Between Indoorand Outdoor Units Of Suitable Size ( Both Suction And Discharge Piping Will Be Treated As One Unit And Will Not Be Measured Separately ) , Suction Line And Discharge Line Both With Insulation, Frp / Glass Cloth Rapped Over Insulation From Indoor To Outdoor Unit With Uv Resistant Paint; Anti Corrosive Paint For Exposed Copper Piping, Joints, Fittings, Accessories; Core Cutting In Brick / Concrete Wall As Required And Making Surface Good, Supports Etc. For 3Trcapacitycassette Ac Units 150 Supply, Erection, Testing And Commissioning Of Refrigerant Grade Copper Piping Between Indoorand Outdoor Units Of Suitable Size ( Both Suction And Discharge Piping Will Be Treated As One Unit And Will Not Be Measured Separately ) , Suction Line With Insulation And Discharge Line Without Insulation, Epoxy / Frp Uv Resistant Paint Suitable For Exposed Insulation And Anti Corrosive Paint Suitable For Exposed Copper Piping And Joints, Fittings, Accessories, Core Cutting In Brick / Concrete Wall As Required And Making Surface Good, Supports Etc. For 1.5Trcapacity High Wall Split Ac Units 151 Providing Voltage Stabiliser Of Suitable Rating For Input Range Of 180 V To 260 V With Time Delay, High / Low Cut Off, Meter To Read Input And Output Voltages, On / Off Switches Etc. As Required Suitable For 1.5Tr High Wall Split Ac Units 152 Providing Voltage Stabiliser Of Suitable Rating For Input Range Of 180 V To 260 V With Time Delay, High / Low Cut Off, Meter To Read Input And Output Voltages, On / Off Switches Etc. As Required Suitable For 3Tr Cassette Ac Units 153 Providing And Laying Of Cpvc ( Sdr11 ) Pipes Of 25 Mm Dia, With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation Laminated With Glass Cloth And Uv Paniting Of Thickness As Specified In Tender For Condensate Water Drain From The Split Ac Indoor Units To Nearest Drain Point, Fittings, Supportincluding Core Cutting In Brick / Concrete Wall As Required And Making Surface Good Etc. Complete 154 Providing And Laying Of Cpvc ( Sdr11 ) Pipes Of 32 Mm Dia, With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation With Frp / Glass Cloth Rapped Over Insulation For Condensate Water Drain From The Ac Indoor Units To Nearest Drain Point, Fittings, Supportincluding Core Cutting In Brick / Concrete Wall As Required And Making Surface Good Etc. Complete 155 Providing And Laying Of Cpvc ( Sdr11 ) Pipes Of 40 Mm Dia, With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation With Frp / Glass Cloth Rapped Over Insulation For Condensate Water Drain From The Ac Indoor Units & Ahus To Nearest Drain Point, Fittings, Supportincluding Core Cutting In Brick / Concrete Wall As Required And Making Surface Good Etc. Complete 156 Providing And Laying Of 75Mm Size Pvc Casing Suitable For Refrigerant Piping And Control Cable Between Split Ac Indoor And Outdoor Unit With Necessary Fittings, Supports Etc., All As Specified And / Or Directed Complete 157 Supply, Installation, Testing And Commissiong Of Inline Type Propeller Fresh Air Fan Ofcapacity Not Less Than 150 Cfm, Pressure Not Less Than 15 Mm Esp With Canvass / Flexible Duct As Required For Connecting The Inline Fan To The Fresh Air Intake Duct Including Providing Plenum If Required For Connecting The Fresh Air Fan To The Duct And Providing Filter, Louvre, Bird Screen At The Air Intake Point With Necessary Clamps, Screws Etc., All As Specified And / Or Directed Etc., Complete 158 Supply, Fabrication, Installation, Testing And Commissioning Of Site Fabricated Gi Sheet Metal Ducts Of 24 Guage ( Birmingham Gauge ) ( 0.63 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Complete Withsupports, Rubber Gaskets, Rivets, Flanges, Etc., All As Specified And / Or Directed Etc., Complete. Note:1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 159 Supply, Fabrication, Installation, Testing And Commissioning Of Site Fabricated Gi Sheet Metal Ducts Of 22 Guage ( Birmingham Gauge ) ( 0.8 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Complete Withsupports, Rubber Gaskets, Rivets, Flanges, Etc., All As Specified And / Or Directed Etc., Complete. Note:1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 160 Supply, Fabrication, Installation, Testing And Commissioning Of Site Fabricated Gi Sheet Metal Ducts Of 20 Guage ( Birmingham Gauge ) ( 1.0 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Complete Withsupports, Rubber Gaskets, Rivets, Flanges, Etc., All As Specified And / Or Directed Etc., Completenote:1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 161 Supply, Fabrication, Installation, Testing And Commissioning Of Factory Fabricated Gi Sheet Metal Ducts Of 24 Guage ( Birmingham Gauge ) ( 0.63 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Including Necessary Hangers, Supports, Rubber Gaskets, Rivets, Flanges Etc., All As Specified And / Or Directed Etc., Complete Note: 1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 162 Supply, Fabrication, Installation, Testing And Commissioning Of Factory Fabricated Gi Sheet Metal Ducts Of 22 Guage ( Birmingham Gauge ) ( 0.8 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Including Necessary Hangers, Supports, Rubber Gaskets, Rivets, Flanges Etc., All As Specified And / Or Directed Etc., Complete Note: 1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 163 Supply, Fabrication, Installation, Testing And Commissioning Of Factory Fabricated Gi Sheet Metal Ducts Of 20 Guage ( Birmingham Gauge ) ( 1.0 Mm ) And Zinc Coating Not Less Than 120 G / M2 In Accordance With Approved Drawings Including Necessary Hangers, Supports, Rubber Gaskets, Rivets, Flanges Etc., All As Specified And / Or Directed Etc., Complete Note: 1 ) The Rate Quoted For The Gi Ducting Deemed To Include The Cost Of Ms Supports. The Ms Supports Provided For Gi Ducting Will Not Be Measured And Paid Separately. 164 Supplying And Fixing Thermal Insulation For Supply Air Ducts With 19 Mm Thick Self Adhesive Closed Cell Elastomeric ( Nitrile Rubber ) Sheet Reinforced With Aluminium Foilor Closed Cell Physically Crosslinked Polyolefin Foam Reinforced With Aluminium Foil All As Specified And / Or Directed Etc., Complete 165 Supplying And Fixingthermal Insulation For Return Air Ducts With 13 Mm Thick Self Adhesive Closed Cell Elastomeric ( Nitrile Rubber ) Sheet Reinforced With Aluminium Foilor Closed Cell Physically Crosslinked Polyolefin Foam Reinforced With Aluminium Foil All As Specified And / Or Directed Etc., Complete 166 Supplying And Fixing Acoustic Insulation For Ducting With Open Cell Nitrile Rubber Insulation Or Open Cell Physically Crosslinked Polyolefin Foam Insulation Of Thickness Not Less Than 15 Mm, Density Of Open Cell Nitrile Rubber Insulation Shall Not Be Less Than 130 Kg / M3 Including Adhesive Or Density Of Open Cell Physically Crosslinked Polyolefin Foam Shall Not Be Less Than 25 Kg / M3 Including Adhesive, Fixing Accessories All As Specified And / Or Directed Etc., Complete 167 Supplying And Laying Of Under-Deck Insulation With 25Mm Thick Closed Cell Elastomeric Nitrile Rubber / Closed Cell Physically Crosslinked Polyolefin Foam With Adhesive ( Fevicol Sr 505 ) , Gi Strip And All Necessary Support All As Specified And / Or Directed Etc., Complete. Note: Insulation Measurement Shall Be As Per The Tender Measurement Clause. 168 Supply, Erection, Testing, Balancing And Commissioning Of Aluminium Powder Coated Supply Air Grill With Vcd, Double Defelection Adjustable Blades As Per Requirement / Approved Drawingsincluding Fixtures, Screws Etc All As Specified And / Or Directed Etc., Complete 169 Supply, Erection, Testing, Balancingand Commissioning Of Aluminium Powder Coated Return Airgrill ( Without Volume Control Dampers ) As Per Requirement / Approved Drawings Including Fixtures, Gasket, Screws Etc., All As Specified And / Or Directed Etc., Complete. 170 Supply, Fixing, Testing & Commissioning Of Supply Air Diffusers With Powder Coated Aluminium Single Piece Moulded Frame With Opposed Blade Aluminium Extruded Construction Black Anodised Dampers As Per Requirement / Approved Drawing Including Fixtures, Gaskets, Screws, Etc., All As Specified And / Or Directed Etc., Complete. 171 Supply, Fixing, Testing & Commissioning Of Return Air Diffusers With Powder Coated Aluminium Single Piece Moulded Frame Without Dampers As Per Requirement / Approved Drawing Including Fixtures, Gaskets, Screws, Etc., All As Specified And / Or Directed Etc., Complete. 172 Supply & Installation Of Factory Fabricated Spill Air Boxes Made Out Of 0.8Mm Thick Gi Sheet With Necessary Spigot Connection For Fixing Flexible Duct And Suitable Collar For Connecting To Various Neck Diffuser / Slot Diffuser.The Box Should Be Internally Insulated With 6Mm Thick Nitrile Rubber Of Class O Material. Box Size Shall Be Of 450X450x350 Mm And Equivalent Required Rectangular Sizes With Gi Wire Support, 16G Gi U-Shaped Brackets With Gi Nut Of Suitable Size Welded To It. 173 Supply, Erection Testing And Commissioning Of Volume Control Dampers Forducts Made Of Gi Sheet Of Thickness Not Less Than 18 G Including Fittings, Gaskets, Nuts.Boltsetc., All As Specified And / Or Directed Etc., Complete 174 Supply, Installation, Testing And Commissioning Ofcombined Fire And Smoke Damper To Be Fitted At The Supply Air Wall Openings ( Inside Wall ) . These Dampers Shall Be Made From Gi Sheet In Multi Blade Construction. The Dampers Shall Be Provided With Seal On Sides To Prevent Spread Of Smoke And Fire. Testing Of Fire Damper Shall Be As Per Ul 555 And Certified By Cbri. All As Specified And / Or Directed Etc., Complete. 175 Supply, Installation, Testing And Commissioning Of Control Instruments And Sensorsrequired For Combined Fire And Smoke Damper Including Actuators, Temperature Sensor And Duct Mounted Smoke Sensor And Auxiliary Switch With All The Necessary Accessories For Fire & Smoke Damper ( Item No. 32 Of Soqr ) All As Specified And / Or Directed Etc., Complete.Note: 1 ) The Item Shall Be Complete With In-Built Temperature Sensor And Duct Mounted Smoke Sensor And Auxiliary Switch To Close The Dampers Simultaneously. 2 ) The Components Provided Under This Item Shall Be Such That The Dampers Also Actuate In Response To Signal From Central Fire Alarm System Which Shall Trip The Indoor Unit Along With Closing The Damper.3 ) The Cabling From The Central Fire Alarm System Upto The Combined Fire And Smoke Damper Will Be Provided By The Fire Alarm System Contractor.4 ) The Damper Will Be Measured And Paid Under The Relevant Item Of Soqr. 176 Supply, Erection Testing And Commissioning Of Fresh / Exhaust Airlouvers Made Of Extruded Aluminium With Bird / Insect Screen Including Volume Control Damper Made Of Aluminium. Note : The Lowest Louvers Of The Assembly Shall Extend Out Slightly To Facilitate Disposal Of Rain Water Without Falling On The Door / Wall On Which It Is Mounted All As Specified And / Or Directed Etc., Complete. 177 Supply, Erection, Testing And Commissioning Of 300Mm Dia. - Butterfly Damper Should Constructed With Not Less Than 0.8Mm Thick Galvanized Steel Sheet, With Single Flap, Necessary Stopper, Flanges For Fastening On To The Duct Surface And With Grooves For Clamping The Flexible Ducts Securely All As Specified And / Or Directed Etc., Complete 178 Supply, Erection, Testing And Commissioning Of 250Mm Dia. - Butterfly Damper Should Constructed With Not Less Than 0.8Mm Thick Galvanized Steel Sheet, With Single Flap, Necessary Stopper, Flanges For Fastening On To The Duct Surface And With Grooves For Clamping The Flexible Ducts Securely All As Specified And / Or Directed Etc., Complete 179 Supply, Erection, Testing And Commissioning Of 100 Mm Dia. - Butterfly Damper Should Be Constructed With Not Less Than 0.8 Mm Thick Galvanized Steel Sheet, With Single Flap, Necessary Stopper, Flanges For Fastening On To The Duct Surface And With Grooves For Clamping The Flexible Ducts Securely.All As Specified And / Or Directed Etc., Complete 180 Supply, Erection Testing And Commissioning Of Aluminium Flexible Duct Of 300 Dia With Insulation All As Specified And / Or Directed Etc., Complete 181 Supply, Erection Testing And Commissioning Of Aluminium Flexible Duct Of 250 Dia With Insulation All As Specified And / Or Directed Etc., Complete 182 Supply, Erection Testing And Commissioning Of Aluminium Flexible Duct Of 100 Mm Dia With Insulation All As Specified And / Or Directed Etc., Complete. 183 Supply And Fixing Of Hand Held Carbon Dioxide Type Fire Extinguisher Of 4.5 Kg Capacity As Per Is - 2878, Duly Charged, With Bis / Isi Mark, Complete With Accessories Including Placing At A Suitable Location With Floor Mounting Type Ms Stand Or Mounting With Suitable Fixture On Wall / Column Etc., All As Specified And / Or Directed Complete. The Contractor Has To Furnish A Copy Of Bis / Isi Certificate And Controller Of Explosive Certificate Along With The Extinguishers, Complete In All Respect. 184 Supply And Fixing Of Hand Held Fire Extinguisher - Abc Powder - 6 Kg Capacityas Per Is - 13849 / 14609, Duly Charged, With Bis / Isi Mark, Complete With Accessories Including Placing At A Suitable Location With Floor Mounting Type Ms Stand Or Mounting With Suitable Fixture On Wall / Column Etc., All As Specified And / Or Directed Complete. The Contractor Has To Furnish A Copy Of Bis / Isi Certificate Along With The Extinguishers, Complete In All Respect.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
TenderDetail
Loading tenders