View Bid Results For Mess Equipments Tenders

We found 217 Bid Results related to mess equipments tenders. You can find Contractor details who won mess equipments tenders along with contract details in Bid awards announcements section.

Filters
Stage
182
23
12
Tender Publishing Platform
85
132
State / UT
29
25
25
19
17
16
15
11
10
10
8
7
6
6
6
5
4
4
4
3
3
3
2
2
1
1
1
1
1
1
Contract Value
50
55
89
23
Publish Date
1
0
0
0
0
Sector
16
144
25
10
8
6
5
4
3
3
2
2
1
1
1
1
1
Ownership
4
125
79
7
6
Within keyword
Active filters:
Showing 1–5 of 217 tenders matching your filters
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
3.
Power #11314309 Price Bid
Tender for Strenthning Of 33 Kv Line B.Plan 2026-27 Scheme At Various Site Of Edd-Hapur, Under Edc Hapur (3 No. Work) (Dpr N0. 13, 14, 15) , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 11.0M Long , 33 Kv Xlpe Cable 3X300 Sqmm , 33 Kv Termination Kit 3X300 Sqmm O/D , 33 Kv Polymeric Pin Insulator With Pin , 33Kv V-Type Cross Arm , Earthing Complete , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , 33 Kv Xlpe Cable 3X300 Sqmm , 33 Kv Termination Kit 3X300 Sqmm O/D , 33 Kv Polymeric Pin Insulator With Pin , 33Kv V-Type Cross Arm , Earthing Complete , Erection And Fixing Of Pole Structure For Plain Cement Concrete Pole 11 Mtr 33 Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 50×6 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Grouting Of Plain Cement Concrete Pole 11 Mtr Supports In cement concrete 1:4:8 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:4:8 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying Of 33 Kv Ht Xlpe Cable Of Size 3×300Sq.Mm Underground Through Manual Method Digging Briks And Sands, Including Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Laying Of 140 Mm Dia (O/D) Pn-4, Pe-80 Grade, Uv Stabilized Hdpe Pipe In Standard Lengths (6 M Each) By Hdd Method For Laying Of Underground Cable, Complete In All Respects As Per Relevant Is Specifications And Directions Of The Site In-Charge; The Scope Of Work Includes Formation Of Entry And Exit Pits, Drilling With Suitable Machinery And Drilling Fluid, Alignment, Jointing, Insertion Of Pipe, Protection Of Existing Utilities, And Complete Site Restoration; The Work Also Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Materials, Safety Arrangements And All Allied Works Required For Proper Execution; The Contractor Shall Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying Of 33 Kv Ht Xlpe Cable Of Size 3×300Sq.Mm Including Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of M.S. Channel 100X50x5mm And M.S. Angle 65X65x6mm Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , M.S. Channel 125X65x6mm , M.S. Angle 65X65x6mm , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Safe De-Erection And Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Installation Of Increasing Cap. 100-250 Kva Dt In B.Plan 2026-27 Scheme At Various Site Of Edd-I Hapur, Under Edc Hapur (10 No. Work) (Dpr N0. 476, 477, 478, 482, 483, 485, 487, 492, 496 & 581 ) , Safe Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 8.5M Long , 11/0.440 Kv 250 Kva Dt , Lt Ab Cable 3X120+1X95+1X16 Sqmm , Lt Pvc Alu. 1X240 Sqmm , Lt Pvc Alu. 3.5X400 Sqmm , 11Kv Polymeric Pin Insulator With Pin , 11Kv Disc Insulator T&C Type 45 Kn With Fitting , Earthing Complete , Stay Set Complete , 11 Fuse Set , Erection And Fixing Of Double Pole Structure For Plain Cement Concrete Pole 8.5 Mtr 11Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Grouting Of Plain Cement Concrete Pole 8.5 Mtr Supports In cement concrete 1:4:8 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:4:8 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of M.S. Channel 100X50x5mm And M.S. Angle 65X65x6mm Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Double Pole Clamps Including, Holding Clamps, Top Channel Clamps, Dropper Channel Clamps Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Follwings Petty Meterial As Per As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Barbed Wire , 11 Kv Danger Board , Providing & Fixing Of High Quality Long Barrel Al. Lugs Off Size. Each Lug Must Be Crimp By Proper Crimping Tool As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of High Quality Henley Type Tailless Unit Protection Cubical Panel 500A, 650V For 250 Kva Dt Including Fixing Of All Accessories By Providing All Required Materials Such As Long Barrel Lugs, Glands, Nuts & Bolts Etc.) Each Lug Must Be Crimp By Proper Crimping Tool As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv D.O. Fuse Set Protection Unit For 250 Kva Dt Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Lugs, Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 11/0.440 Kva 250 Dt With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm Using Suspension Clamps, I-Hook And Dead End Clamp Inculding Jumpering Work With Peircing Connector, Cable Connection With Distribution Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Erection And Laying Of Lt Pvc Alu. 1X240 Sqmm Inculding Proper Connection With Long Barrel Lug, Proper 3 Nos Crimping On Each Lug, Lt Fuse Set/Smc Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Fixing And Grauting Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Stay Set And Stay Wire Will Be Provided By Department. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Erection Of Chemical Earthing For Neutral Of Dt With Gi Strip 50X6mm Including Excavation Of Pit And Using Necessary Chemical And Electrode To Obtain Results ≤ 1 Ohm, 3M Apart From Support, Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Strip & Earthing Lugs, Nut And Bolts As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Construction Of Tif Plinth Suitable For 250Kva (Size Of 2X2x 1.5 Mtr.) As Per Drawing, cement concrete Work In Foundation In Ratio 1:4:8 (Cement, Sand & Brick Ballast). 1St Class Brick Work In Side Walls cement concrete Ratio Of 1:4 (Cement & Fine Sand). 12Mm Thick Plaster In Ratio 1:4 (Cement & Fine Sand). The Reinforced Cement Concrete Work On Top Of Plinth In Ratio 1:2:4 Are Duly Filling Of Brick Ballast Inside The Plinth & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction O Site Incharge. , Provinding & Fixing Of Safety Fencing (Ms) For 11/0.4 Kv, 250Kva Dt, With Supply Of Material Required For Ms Fencing Upto Dt Upper Level By Constructing 1 Feet Masnary Wall With Bricks & 4X8 Feet Frames Bolted And Welded Alongwith, The construction Of Frames With 75X75x6 Mm Corrosion Free Ms Angle, 8 Swg M.S. Gi Wire Mess Corrosion Free Made Of Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Angle To Be Fitted On Vertical Posts. And Dual Door Gate To Facilitate Entry And Exit With Locking Arrangements. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Gi Angle . Such Post Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Metalic Materilas Should Be Galvanized & Corrosion Free) , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Safe Dismentling And Carriage Of Old & Used 11/0.440 Kv 100 Kva Dt From Site To Electricity Store Centre At Hapur Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Installation Of Increasing Cap. 25-100 Kva Dt In B.Plan 2026-27 Scheme At Various Site Of Edd-I Hapur, Under Edc Hapur (5 No. Work) (Dpr N0. 535, 540, 541, 542 & 547) , Safe Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 8.5M Long , 11/0.440 Kv 100 Kva Dt , Lt Ab Cable 3X120+1X95+1X16 Sqmm , Lt Ab Cable 3X95+1X70+1X16 Sqmm , Lt Pvc Alu. 3.5X150 /70 Sqmm , Earthing Complete , Stay Set Complete , Lt Distributon Box , 11 Fuse Set , Erection And Fixing Of Single Pole Structure For Plain Cement Concrete Pole 8.5 Mtr 11Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Grouting Of Plain Cement Concrete Pole 8.5 Mtr Supports In cement concrete 1:4:8 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:4:8 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Single Pole Clamps Including, Holding Clamps, Top Channel Clamps, Dropper Channel Clamps Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Follwings Petty Meterial As Per As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Suspension Clamps , I-Hook , Peircing Connector 95 Sqmm , Barbed Wire , 11 Kv Danger Board , Providing & Fixing Of Lt Fuse Set Protection Unit For 100 Kva Dt With Smc Box Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv D.O. Fuse Set Protection Unit For 250 Kva Dt Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Lugs, Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 11/0.440 Kva 100 Dt With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm Using Suspension Clamps, I-Hook And Dead End Clamp Inculding Jumpering Work With Peircing Connector, Cable Connection With Distribution Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X95+1X70+1X16 Sqmm Using Suspension Clamps, I-Hook And Dead End Clamp Inculding Jumpering Work With Peircing Connector, Cable Connection With Distribution Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Erection And Laying Of Lt Pvc Alu. 3.5X150/70 Sqmm Inculding Proper Connection With Long Barrel Lug, Proper 3 Nos Crimping On Each Lug, Lt Fuse Set/Smc Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Fixing And Grauting Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Stay Set And Stay Wire Will Be Provided By Department. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Repalacement Of 33 Kv Vcb In B.Plan 2026-27 Scheme At 33/11 Kv Rampur Road S/S, Edd-I Hapur, Under Edc Hapur (01 No. Work) (Dpr N0. 19) , Safe Carriage Of 33 Kv Vcb 800A, 750Mva With Steel Structure From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Erection Of 33 Kv Vcb 800A, 750Mva With Steel Structure In 33/11 Kv Rampur Road S/S Inculding Connection Of Control Cables Etc. The Steel Structure Must Be Connected With Existing Earthing By 50X6 Mm Gi Strip As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Gi Strip Shall Be Provided By Contractor , Providing And Fixing Of 4X2.5 Sqmm Copper Control Cable In Switch Yard Though Trench And Upto Vcb Panel As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
4.
Power #11314307 Price Bid
Tender for Strenthning Of 11 Kv Line B.Plan 2026-27 Scheme At Various Site Of Edd-Hapur, Under Edc Hapur (17 No. Work) (Dpr N0. 44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60) , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 11.0M Long , Plain Cement Concrete Pole 8.5M Long , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , 11Kv Xlpe Cable 3X120 Sqmm , 11Kv Xlpe Cable 3X185 Sqmm , 11Kv Termination Kit 3X185 Sqmm O/D , 11Kv Termination Kit 3X120 Sqmm I/D , 11Kv Termination Kit 3X120 Sqmm O/D , 11Kv Polymeric Pin Insulator With Pin , 11Kv Polymeric Disc Insulator With Fitting , 11Kv V-Type Cross Arm , Earthing Rod , G.I. Wire 6Swg , G.I. Wire 8Swg , Stay Set , Stay Wire 7/10 Swg. , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , 11Kv Termination Kit 3X120 Sqmm I/D , 11Kv Termination Kit 3X120 Sqmm O/D , 11Kv Polymeric Pin Insulator With Pin , 11Kv Polymeric Disc Insulator With Fitting , 11Kv V-Type Cross Arm , Erection And Fixing Of Pole Structure For 11Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Grouting Of St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:3:6 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Laying, Stringing And Final Sagging Of Acsr Weasel/Rabbit/Dog Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Acsr Weasel Conductor , Acsr Rabbit Conductor , Acsr Dog Conductor , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×120Sq.Mm Underground Through Manual Method Digging Briks And Sands, Including Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Laying Of 140 Mm Dia (O/D) Pn-4, Pe-80 Grade, Uv Stabilized Hdpe Pipe In Standard Lengths (6 M Each) By Hdd Method For Laying Of Underground Cable, Complete In All Respects As Per Relevant Is Specifications And Directions Of The Site In-Charge; The Scope Of Work Includes Formation Of Entry And Exit Pits, Drilling With Suitable Machinery And Drilling Fluid, Alignment, Jointing, Insertion Of Pipe, Protection Of Existing Utilities, And Complete Site Restoration; The Work Also Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Materials, Safety Arrangements And All Allied Works Required For Proper Execution; The Contractor Shall Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×185Sq.Mm In Hdpi Pipe By Safly Pulling, Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Gi Pipe 6 Inch Dia Along With Suitable Clamps, Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Fixing And Grauting Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Stay Set And Stay Wire Will Be Provided By Department. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of M.S. Channel 100X50x5mm And M.S. Angle 65X65x6mm Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , M.S. Channel 100X50x5mm , M.S. Angle 65X65x6mm , Providing And Fixing Guarding Angle Size 50*50*5 And Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Gi Wire Will Be Provided By Department). , Providing And Installation Of Maintenance-Free, Multifaceted, Corrosion-Resistance Free Gi Pipe Earthing Upto Water Level Pipe Dia 2 Inch 80Feet. Providing And Fixing Of Gi Earth Strip Size 50Mm*6Mm For Connection (The Strip To Be Properly Welded To The Earthing Electrode And Neutral Support), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Excavation, Installation, Welding, Connection, Testing, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Construction Of 11 Kv Line B.Plan 2026-27 Scheme At Various Site Of Edd-Hapur, Under Edc Hapur (01 No. Work) (Dpr N0. 69) , Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 8.5M Long , 11Kv Xlpe Cable 3X185 Sqmm , 11Kv Termination Kit 3X185 Sqmm O/D , 11Kv Polymeric Pin Insulator With Pin , 11Kv V-Type Cross Arm , Earthing Complete , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , 11Kv Termination Kit 3X185 Sqmm O/D , 11Kv Polymeric Pin Insulator With Pin , 11Kv V-Type Cross Arm , Erection And Fixing Of Pole Structure For Plain Cement Concrete Pole 8.5 Mtr 11Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Grouting Of Plain Cement Concrete Pole 8.5 Mtr Supports In cement concrete 1:3:6 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:3:6 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Digging Of Trech As Per Respo Drawings/Standard Norms For 11 Kv Ht Xlpe Cable Of Size 3×185Sq.Mm Underground Through Manual Method Digging Briks And Sands, Including Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Including Proper Installation And Commissioning At Site.Including Machinery, Drilling/Excavation, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues Measurement Shall Be Made On Actual Length Of Trech At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. And Completing The Work As Per Directions Of Engineer-In-Charge , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×185Sq.Mm (Double Ckt) Underground Through Manual Method Digging Briks And Sands, Including Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Gi Pipe 6 Inch Dia Along With Suitable Clamps, Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of M.S. Channel 100X50x5mm Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Providing And Fixing Of Gi Pipe 6 Inch Dia Along With Suitable Clamps, Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Installation Of 250 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-I Hapur, Under Edc Hapur (5 No. Work) (Dpr N0. 102, 103, 104, 105 & 107 ) , Safe Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Plain Cement Concrete Pole 11.0M Long , 11/0.440 Kv 250 Kva Dt , Acsr Weasel Conductor , Lt Ab Cable 3X120+1X95+1X16 Sqmm , Lt Pvc Alu. 1X400 Sqmm , Lt Pvc Alu. 1X240 Sqmm , Lt Pvc Alu. 3.5X400 Sqmm , 11Kv Polymeric Pin Insulator With Pin , 11Kv Disc Insulator T&C Type 45 Kn With Fitting , Earthing Complete , Stay Rod , 11 Fuse Set , Stay Wire 7/10 Swg. , Erection And Fixing Of Double Pole Structure For Plain Cement Concrete Pole 11 Mtr 11Kv Ht Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Grouting Of Plain Cement Concrete Pole 11 Mtr Supports In cement concrete 1:4:8 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:4:8 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of M.S. Channel 100X50x5mm And M.S. Angle 65X65x6mm Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Double Pole Clamps Including, Holding Clamps, Top Channel Clamps, Dropper Channel Clamps Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Danger Board Of Approved Design And Size, Made Of Suitable Weatherproof Material With Required Painting And Lettering, Including Fixing On Pole/Structure With Nuts, Bolts, Clamps And All Necessary Labour, Tools & Plants For Complete And Satisfactory Execution Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Providing & Fixing Of High Quality 3 Phase 4 Wire 440V, 400A, ≥ 35Ka, With Overload Short Ckt And Earth Falt Protection, Outdoor Type, Weather Proof Lt Mcb With Box With Locking Arrangement For 11/0.440Kv, 250 Kva Dt With Long Barrel Al. Lugs Off Size. Each Lug Must Be Crimp By Proper Crimping Tool As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of High Quality Long Barrel Al. Lugs Off Size. Each Lug Must Be Crimp By Proper Crimping Tool As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of High Quality Henley Type Tailless Unit Protection Cubical Panel 500A, 650V For 250 Kva Dt Including Fixing Of All Accessories By Providing All Required Materials Such As Long Barrel Lugs, Glands, Nuts & Bolts Etc.) Each Lug Must Be Crimp By Proper Crimping Tool As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv D.O. Fuse Set Protection Unit For 250 Kva Dt Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Lugs, Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 11/0.440 Kva 250 Dt With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm Using Suspension Clamps, I-Hook And Dead End Clamp Inculding Jumpering Work With Peircing Connector, Cable Connection With Distribution Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Erection And Laying Of Lt Pvc Inculding Proper Connection With Long Barrel Lug, Proper 3 Nos Crimping On Each Lug, Lt Fuse Set/Smc Box For Proper Completion Of Work As Per Respo Norms, And As Per Direction Of Site Incharge. , Lt Pvc Alu. 1X400 Sqmm , Lt Pvc Alu. 1X240 Sqmm , Lt Pvc Alu. 3.5X400 Sqmm , Fixing And Grauting Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works And Materials Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Stay Set And Stay Wire Will Be Provided By Department. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs, Nut And Botls As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Erection Of Chemical Earthing For Neutral Of Dt With Gi Strip 50X6mm Including Excavation Of Pit And Using Necessary Chemical And Electrode To Obtain Results ≤ 1 Ohm, 3M Apart From Support, Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Strip & Earthing Lugs, Nut And Bolts As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Construction Of Tif Plinth Suitable For 250Kva (Size Of 2X2x 1.5 Mtr.) As Per Drawing, cement concrete Work In Foundation In Ratio 1:4:8 (Cement, Sand & Brick Ballast). 1St Class Brick Work In Side Walls cement concrete Ratio Of 1:4 (Cement & Fine Sand). 12Mm Thick Plaster In Ratio 1:4 (Cement & Fine Sand). The Reinforced Cement Concrete Work On Top Of Plinth In Ratio 1:2:4 Are Duly Filling Of Brick Ballast Inside The Plinth & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction O Site Incharge. , Provinding & Fixing Of Safety Fencing (Ms) For 11/0.4 Kv, 250Kva Dt, With Supply Of Material Required For Ms Fencing Upto Dt Upper Level By Constructing 1 Feet Masnary Wall With Bricks & 4X8 Feet Frames Bolted And Welded Alongwith, The construction Of Frames With 75X75x6 Mm Corrosion Free Ms Angle, 8 Swg M.S. Gi Wire Mess Corrosion Free Made Of Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Angle To Be Fitted On Vertical Posts. And Dual Door Gate To Facilitate Entry And Exit With Locking Arrangements. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Gi Angle . Such Post Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Metalic Materilas Should Be Galvanized & Corrosion Free) , Providing And Fixing Of All Types Of Clamps Suitable For Electrical Line/Equipment Works, Including Supply Of Approved Quality Clamps, Nuts, Bolts, Washers, Fabrication, Fitting, Tightening, And All Necessary Labour, Tools & Plants Required For Complete And Satisfactory Execution Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge. , Providing And Fixing Of Stone Pad Complete In All Respect, Including Supply Of Approved Quality Stone Pad, Necessary Excavation, Dressing, Leveling, Proper Positioning, Packing With Sand/Soil, And All Labour, Tools, Plants, And Materials Required For Satisfactory Completion Of Work As Per Departmental Specifications And Directions Of Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
6.
Power #11269168 Price Bid
Tender for Carriage Of Following Material Of Estimate, From Electricity Store Center, Hapur To Site Of Work With Loading, Unloading Multiple Handling, Staking,Labour,T&P And Transpotation At Both Ends On Kachha/Packka Road, As Per Direction Of Site Incharge From Je Store/Store Center Hapur/Ghaziabad/Bulandshar (0-50 Km) Complete In All Respects. , Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit , Cable Box 3X185 O/D Sqmm 11 Kv , 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake , 11 Kv Fuse Set , Plain Cement Concrete Pole 8.5 Mtr Long. , 11 Kv Pin Insulator Polymer , 11 Kv Disc Insulator Polymer , M.S. Channel 100X50x50 Mm , Earthing Complete , 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit , 11 Kv O/D Xipe 3X300 Sqmm C/J Kit , 11 Kv Through 3X185 Sqmm Xlpe C/J Kit , 33 Kv Circuit Breaker 800A, 750 Mva , Acsr Dog. Conductor , Cable Ht Xipe 3X300 Sqmm 33 Kv , Cable Box 3X300 O/D Sqmm 33 Kv , H/S 33 Kv 3X300 Sqmm J/Kit St. Th , Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. , 11 Kv Vcb Incoming , 33 Kv Pt Outdoor (2Set) (2X3=6) , Battery Set 24 Volt , Battery Charger 24 Volt , 33 Kv Ct 400/200/1 annual periodical maintenance , 33 Kv Ct 200/100/1 annual periodical maintenance , 33 Kv Control Pannel Double T/F , 33 Kv Fuse Set , Eraction And Fixing And Making Connection Of Following Material (As Per Respo Norms) At Diffrent 33/11 Kv Substation Were Include Making Alignment, All Required Nut Bolt, Clamps, Lug, Connector, Wire And Strip Etc All Labour,T&P, Safe & Porper Oprations Provided By Contractor In All Respects. , Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit , Cable Box 3X185 O/D Sqmm 11 Kv , 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake , 11 Kv Fuse Set , Plain Cement Concrete Pole 8.5 Mtr Long. , 11 Kv Pin Insulator Polymer , 11 Kv Disc Insulator Polymer , M.S. Channel 100X50x50 Mm , Earthing Complete , 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit , 33 Kv Circuit Breaker 800A, 750 Mva , Acsr Dog. Conductor , Cable Ht Xipe 3X300 Sqmm 33 Kv , Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. , 11 Kv Vcb Incoming , 33 Kv Pt Outdoor (2Set) (2X3=6) , Battery Set 24 Volt , Battery Charger 24 Volt , 33 Kv Ct 400/200/1 annual periodical maintenance , 33 Kv Ct 200/100/1 annual periodical maintenance , 33 Kv Control Pannel Double T/F , 33 Kv Fuse Set , Providing, Supplying, Laying And Installation Of Hdpe Pipe Of Pe-80 Grade, Pn-6, 200 Mm Diameter By Horizontal Directional Drilling (Hdd) / Trenchless Method For Accommodating 11 Kv, 3×185 Sq.Mm Xlpe Insulated, Armoured Cable, Including Execution Of Road Crossing Or Similar Crossings Wherever Required, Complete With Pilot Drilling, Reaming And Pullback Operations, Proper Jointing Of Hdpe Pipe (Butt Fusion/Electrofusion), All Labour, Tools & Plants, Machinery, Drilling Fluid, Safety Arrangements, Formation Of Entry And Exit Pits And Site Restoration; The Contractor Shall Be Fully Responsible For Obtaining Necessary Permissions, Protection Of Existing Utilities And Resolution Of All Right Of Way (Row/Raw) Issues During Execution. , Laying Of 11 Kv Xlpe Cable Of Size 3X185/3X300 Sq.Mm Undergound Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape At Both Ends As Per Respo/Norms, As Per Direction Of Site Incharge. , 11 Kv Ht Xlpe Cable 3X185 Sq.Mm With Double Circuit , 11 Kv Ht Xlpe Cable 3X300 Sq.Mm With Double Circuit , Providing The Material And Execution Gi Pipe Earthing With 40 Mm Dia B Class Gi Pipe 80 Feet Boar To Water Level For Proper Earthing ( Earthing Resistance Less Than Or Equal To 1 Omh ) At 33/11 Kv Substation With The Help Of 50Mm X 6Mm Gi Strip Duly Welding To Dt Transformer Other Equipment. With Earthing Mess Lug, Nut And Bolt. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing, Supplying And Fixing Of Copper Bus Bar Of Size 80 Mm × 10 Mm Suitable For 11 Kv Vcb Panel, Including Cutting, Drilling, Bending, Proper Alignment, Insulation Clearance, And Secure Fastening With All Required Nuts, Bolts, Washers And Supports, Ensuring Proper Electrical And Mechanical Connections, Complete In All Respects; The Work Shall Include All Labour, T&P Will Be Provided By Contractor In All Respects. , Grouting Of Following Plain Cement Concrete Pole 8.5 Mtr. Long Supports In cement concrete 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Pg Clamps (Parallel Groove Clamps) Of Suitable Sizes For Making Conductor-To-Conductor Connections, Including Dog Conductor To Dog Conductor And Panther Conductor To Panther Conductor Joints, Complete With All Necessary Nuts, Bolts And Accessories, Ensuring Proper Electrical And Mechanical Continuity, As Per Relevant Standards And Directions Of Site Incharge All Labour, T&P Will Be Provided By Contractor In All Respects. , Making And Filling Of 11Kv/33Kv Cable Jointing Kit, Indoor/Outdoor Type, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , 11Kv Cable Jointing Kit 3X185 Sq.Mm. , 11Kv Cable Jointing Kit 3X300 Sq.Mm. , 33Kv Cable Jointing Kit 3X300 Sq.Mm. , Providing And Fixing 11 Kv Relay, With (E/F & O/C) Of C&S, Ashide, Abb Make With 1&5 annual periodical maintenance Port Suitable For 11 Kv Feeder Pannel As Per Respo/Norms And As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor With All Labour, T&P In All Respects. , Providing And Fixing Of Wti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti , As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Oti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti, As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Vaccume Interupter In 11 Kv Pannel, As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing 33 Kv Ct Stracture As Per Respo/Norms And As Per Direction Of Site Inchagre Work Includs Grouting Stracture And Making Plinth As Per Norms All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects. , Dismantling Of Existing Electrical Equipment At Site, Including Proper Handling To Avoid Damage, And Safe Carriage/Transportation From The Work Site To The Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends, Covering All Leads Over Kachcha And Pucca Roads, Complete With All Labour, Tools & Plants, And Necessary Precautions, As Per The Directions Of The Site Incharge. All Labour Will Be Provided By Contractor In All Respects.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
7.
Defence #11150449 AOC
Tender For Provision Of Offers Mess Under Ge (N) Udhampur; 2 Construction of block of Offrs Mess complete all as shown on drawings and as specified. 3 Construction of block of Servant Quarter complete all as shown on drawings and as specified. 4 Construction of block of Car Garage (09 Cars) complete all as shown on drawings and as specified. 5 TotalAmount of Sch A Part - II (Internal Water Supply Work) 6 TotalAmount of Sch A Part - III (Internal Electric Supply Work) 7 TotalAmount of Sch A Part - IV (Plumbing Work) 8 TotalAmount of Sch A Part - V(Area Drainage Work) 9 TotalAmount of Sch A Part - VI (Sewage Disposal Work) 10 TotalAmount of Sch A Part -VII (Road, Path, Culvert and Hard Standing Work) 11 TotalAmount of Sch A Part - VIII (External Water Supply Work) 12 TotalAmount of Sch A Part - IX (External Electric Supply Work) 13 TotalAmount of Sch A Part -X (Compound Wall , Fencing and Gate Work) 14 TotalAmount of Sch A Part -XI (Hot Water Supply Work) 15 Sch A Part - XII (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 16 Construction of septic tank for 50 users (Brick construction) complete all as shown on drg No. CEUZ /TD-1585/2021 sheet 1/4 to 4/4 and as specified. 17 Construction of soakage well (Brick construction) 1.8m dia and 3.0m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. 18 Supply, installation and comminssioning of water cooler, fully stainless steel, electric driven single phase having storage capacity 120 litres and nominal cooling capacity of 60 Litres per hour, fitted with hermetically sealed air compressor operating on refrigerant R-134a or 410a, conforming to IS-1391 Part-II) complete all as specified and directed. 19 Supply, installation and comminssioning of refrigerator, double door BEE 5 star rated frost free, digital inverter with hermetically sealed compressor of min capacity 256 litres suitable to use on 230 volt, AC supply complete all as specified and directed. 20 Supply, installation and comminssioning of metal top deep freezer BEE 5 star rated hard top having capacity 320 litres, double door, single phase 240 V, 50Hz, complete all as specified and directed. 21 Voltage stabilizer for automatic operation, single phase naturally air cooled, indoor type, wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 2 KVA, complete all as specified and directed. 22 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating inverter technology and EER 3.2, single phase, capacity 1.5 TR, complete all as directed. 23 Supply, installation, testing and comminssioning hi wall split unitsindoor/outdoor complete with cordless remote control unit and within built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating inverter technology and EER 3.2, single phase, capacity 2.0 TR, complete all as specified and directed. 24 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 4 KVA, complete all as specified and directed. 25 Voltage stabilizer for automatic operation, single phase naturally air cooled indoor wall mounted type & designed for input variation between 170 volts to 250 volts with output stabilized voltage at 230 volts with accuracy of ± 2.5% and of capacity 5 KVA, complete all as specified and directed. 26 Supply, installation, testing and commissioning of solar hot water heating system (Flat plate collector) based on indirect transfer of heat for 300 liters as per IS-12922 and IS-12978 with electrical backup of 2KW, including angle iron support (60mmx60mmx6mm) with nut, bolts, washers and painting with two coat of synthetic enamel paint over one coat of red oxide primer for mounting of hot water plant and cold storage tank, complete all as specified and as directed.Note:- Cold water storage tank shall be measured and paid separately. 27 Construction of valve pit of size (90x60x60)cm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 coping with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts in coping including painting of steel surface with two coats of synthetic enamel paint over a coat of redoxide primer as finishes coat including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and directed. 28 Supply , installation, testing & commissioning of transformer of capacity 100KVA step down outdoor type level - III, copper wounded, 11/0.433KV (at no load) AC 3 phase, vector group Dyn 11, 50HZ on secondary side double wound oil immersed naturally air cooled with external cooling tubes /radiator , delta connected as on primary and star connected with netural brought out on secondary side and having tapping at -2.5% to +7.5% in steps of 2.5% to be changed by external hand operated self position off load tap change switch. Also provision shall be made for locking the taping switch handle in position. The maximum temperature rise shoud not exceed 35 degree centigrade on top of oil when measured on thermometer and 40 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirming to IS 1180-2014 transformerlossess shall be as per latest ammendment No IV as per IS 1180 part - I 2014 and comprising of following accessories complete all as specified and as directed. (Contd.../) 29 a) 03 No porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods nuts.b) 01 No cable end box on LV secondry side consisting of 05 No porcelain bushing (One No neutral earth, One No Neutral and 3 No for phaseconnected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core 400 Sqmm cable 3 runs, LT 1100 V grade XLPE insulated heavy duty including gland joint complete. c) Oil conservator with filter type drain valve and oil level guage.d) Dehydrating breather with first filling of dehydrating agent e) Explosive vent.f) THERMOMETER pocket including temperature gaugeg) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strips.(Contd.../) 30 h) OneNo thermometer dail type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge : Max reading painted terminal.i) Rating plate with terminal plate.j) Oil level guage.k) Oil drain filter valve.l) Oil filling hole on top cover with plug.m) Air release valve/plug.n) 4 Nos plain solid cast steel detachable rollers. o) First fill of tranformer oil conforming to relevent ISI and tested upto 60 KV dielectric strength.p) Two No lifting hook at side of transformerNote : Transformer must be as per Energy efficiency Level-3 of IS: 1180:2014 with amendment No. 4. 31 Construction of PCC platform for transformer of size 3m x 3m and 1m high from ground level with brick construction in walls and steps, PCC 1:5:10 type E-2 in foundation, brick workin CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushedstone aggregate). In flooring40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer complete duly surrounded with XPM fencing of length not less than 15 meter and width not less than 10 meter complete with 40mmx5mm angle iron & 12mm dia steel bars, fixed on PCC gate pillers complete including sliding bolt, locking arrangements hinges and all accessories,shown on drawing No CE/TD/1129/96 sheet No. 1/2 & 2/2complete all as specified. 32 Earthing complete with galvanized steel earth plate electrode600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 33 10W decorative inverted tripod type LEDBollard with IP-65 protection, soft 360 degree light distribution body made of die cast aluminium & in triangular shape including 10 W LED with IP 65 ingress protection, 4 KV surge protection, Luminaire should have high efficiency isolated poted driver minimum height of bollard 800mm & with 180mm OEM should have inhouse NABL approved Lab & submit LM-79 report along with NABL certificate, PCC foundation with necessary nuts & bolts complete all as directed by GE. 34 Post top lantern, LED type, 40 watt including40 watt LED AC, outdoor type with decorative post top for 360 degree indirect light IP 66 protection with impact, glare free and better uniformity and corrosion resistant, LED driver shall be constant current type potted driver, luminaire shall have surge protection devices of minimum 10KV inside the driver compartment. Total harmonic distortion shall be <10% with power factor minimum 0.95.The driver shall have an effiviency>85%. It should give consistent performance in the input voltage range of 120V-270V at 50Hz, luminaire shall be embossed or screen printed with manufacturer name/logo, OEM should have in house NABL approved lab and submit LM79 report along with NABL certificate, PCC foundation with necessary nuts and bolts complete with driver and lamp complete all as specified and as directed. 35 Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mmas earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC covermade out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle andangle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 36 Sintex box of size 155mmX210mmX92mm, hinged (L) wiith 2 way connector mounted on epoxy insulators for looping of cablefor phase and neutral fixed on polewith the help of MS nuts bolts and MS clamps; 2 No of size 40mm X 4mm thick, with one No MCB SP 6 Amp capacity mounted on din rail inside box, including making suitable hole in pole to take out connections to fitting if required at site and provisioning of conector of street light, complete all as specified.Make:- Hensel, Sintex or equivalent make approved by GE. 37 LED street light fitting 70 Watt, 230 V, AC, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed. 38 Supply, installation, testing and commissioning offactory made outdoor type CPRI approved dust and vermin proof LT panel board front opening (double shutter) with locking arrangement of suitable size made out of 3.15 mm thick CRCA sheet with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring,thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1)of suitable size as per panel board 0.5mtr above ground level grouting and bottom portion of enclosure shall be minimum 30cm above ground level of legs of angle ironand supply & comprising of the following including internal pre-wiring complete:- 39 INCOMING(i) MCCB 4 pole 160 Amp 16 KAKA thermal magnetic adjustable type- 01 No. (Incoming) (ii) Voltmeter 0-500 V with selector switch(Digital type) - 01 set. (iii) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set(iv) Indicator lamp neon/ LED type RBY -01 Set of three.v) Aluminium bus bar capacity 250 Amps for Phase-R-Y-B- N - 4 No.OUTGOING:(i) MCCB 3 pole 125 Amp 16 KA thermal magnetic adjustable type -02 No. (Outgoing)(ii) MCCB 3 pole40 Amp 16 KAKA thermal magnetic adjustable type01 No. (Outgoing)(iii) MCB SPN 32 Amps 10 KA - 01 No (Outgoing)(iv) Time switch 250 V single phase of 20 Amp rating - 01 No(v) Complete wiring of the panel board with FRLSH PVC insulated multistrand copper conductor cables of suitable current carrying capacity end terminated with lugs and bolts, nuts and washers of galvanised iron.Note: The rate quoted should include the cost ofexcavation/PCC work as per manufacturers recommendation. 40 Bracket made out of GI tubing 40mm dia, light grade 1.5mtr long including fixing withMS clamps - 2 No made out of 50mm wide, 5mm thick, flat iron with M.S nuts bolts 75 mm long 12mm dia, - 4 No with flat washer (3mm thick) - 02 No including painting with two coats of aluminium paint over one coat of red oxide to the M.S clamps & bracket etc complete, including 1.5sqmm 3.0 core, flexible Copper cable from juction box to connecter of street light fitting complete all as specified and as directed. . 41 Cable route marker with route indication at every 30m length on cast iron disc of 100mm dia and 5mm thick, marked/written for HT cable 11000 VOLTS embosed including indication direction fixed/bolted to 40mm x 40mm x 6mmthick MS angle iron support of 0.50 m long embedded upto 200mmdepth in concrete block of size 200mmx200mmx500mmcasted in PCC 1:3:6 type C-1 including painting with two coats of synthetic enamel paint over a coat of red oxide primer to exposed steel surface, complete all as specified and as directed. 42 Road crossingby adopting trenchless tunneling work through specilised pipe jacking method by errecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any kindof soil including hard rock,inserting DWC HDPE casing pipe in any length, and necessary conveyance charges of machinery and other required materials in co-ordination with the concered authorites all as specified and as directed. Note: Quoted rate is deemed to be inclusive of all necessary tools/plant/machinery and obtaining necessary permissions to carryout the work. 43 Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed,multistranded,single core, copperconductor cable 1100 volts grade colour code cablesdrawn through and including PVCConduit 20mm dia medium grade andincluding cutting, chasing work at any height and all accessories are concealedinwalls / roofs / floors / ceiling etc; metal flush boxes suitable modules as directed with top, bottom, side/back wall knockout for conduitentry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved coloursandincluding 1.5 Sqmm PVC insulated multistranded FRLSHunsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor andconnecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providingputty and white cementfor smooth finishing of existing surfacecomplete all as specified and directedfor the following:- 44 One light/fan/bellpoint controlled by one switch 45 One 3/5 pin socket outlet, 5 Amp on independent board 46 One socket outlet 3 Pin, 5 Amps, on the same board 47 One two way point controlled by one 2 way switch 48 One light point controlled by 2 way switches, 49 Point wiring for power point control by one switch with 2.5 Sqmm nominal area PVC insulated single core multi standard copper conductor FRLSH insulated and undheathed heavy duty cable in colour code including earth wire with cable of size 2.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed in PVC conduit of not less than 20mm dia and 1.5mm wall thickness (ISI marked) terminated into annealed steel terminal boxes including modular frame and cover plate for fixing of switches, sockets etc; complete all as specified and as directed. 50 Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia, medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly, complete all as specified and as directed.Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 51 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 sqmmas earth continuity conductorconnected to commen earth dolly complete all as specified and directed.Note: - Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 52 Sub main wiring with four run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade ISI marked 25mm dia or above required including two run ofsingle core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed.Note: - Four run of 6 sqmm single core copper conductor cable and two run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 53 Sheet metal, VTPN distribution board (DB) fitted with DPX3, 160 MCCB, 04 way, (DPX3 -160 +12), complete with metal door, 415 volts rating and IP 56 protection the DB shall be fixed flush to wall and including all internal connection, necessary reducer lugs all as directed by Engr-in-Charge. 54 MCB, Single pole, 240 volt, 40 Amp, 10KA rating,C curve, complete with connection testing and commissioning, complete all specified and directed. 55 Deduction to be made from BOQfor Sch A Part -XIII (Schedule of credit) during AOC.Note: Tenderers shall not quote for this schedule.
Contract Date: May 23, 2026 Contract Value : 4.61 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Jammu And Kashmir View Result →
8.
Home Affairs #11096827 AOC
PURCHASE OF DIFFERENT ARTICLES FOR DEPARTMENTAL STORE OF SPECIALIZED INDIA RESERVE BATTALION, RAJNAGAR, BIRBHUM. Purchase Of Miscellaneous Articles For Departmental Store , Alluminium Utensil , Alluminium Ladder (8) , Allen Key Set , All-Outliquidator Machine , All-Out Liquidator , Alluminium Can (Big Size) , Alluminium Degchi (Raja) , Alluminium Frying Pan (Taj) , Alluminium Gamla (Taj) , Alluminium Handi (Raja) , Alluminium Karai (Raja) , Alluminium Nouka / Rice Tub (Raja) , Alluminium Plainsheet , Alluminium Saucepan (Raja) , Alluminiun Bucket (12) (Raja) , Alluminiun Bucket (14) (Raja) , Alluminiun Jug (Raja) , Alluminiun Tea Kettle (Raja) , Arial(500 Gm) , Arrowrot , Airwick Freshmatic Automatic Air Freshiner , Asbestos Sheet 2.5’X12’ (Everest) , Axe (Tata) , Bugle Cord , Bugle , Breath Analyzer , Blanket Woolen Single , Blanket Woolen Double , Black Tape 09 M Length , Betadine Lotion , Bike Helmet (Bestquality) Isi Mark , Bib Cock Pvc , Bernal , Bp Trumpet , Battery Nippo For Megaphone , Batali , Bass (Big) Drum , Baga Wrench (Pipe Wrench) , B^B Trombone (Tenor) , B^B Euphoniom , B^B Clarinet , Badminton Net (Falcon) , Brasso 250 Ml , Badminton Nylon Shuttle Cock ,Mavis -500(Yonex) , Badminton Racket (Yonex , Gr -303) , Badminton Racket (Yonex, Carbonex 6 Super) , Badminton Racket String , Bamboo Big Size , Bamboo Ladder 20 Fit. , Barbed Wire , Basin ( Hind Wear) , Basin External Pipe , Batterymedium (Eveready) , Battery Calling Bell (Eveready) , Battery Pencil(Eveready) , Battery Remote(Duracell) , Bed Sheet 5’X7’ (Bombay Dying) , Belchabig (Tata) , Bleaching Powder , Bib Cock2 -In -1 , Bib Cock (Brass) , Bib Cock (Steel) , Binocular (1.5 K.M.Range)- Nikon , Bitumin (Pitch) , Black Board Wooden (3’X4’) , Black Paper , Blade For Hacksaw , Brass Bell , Blue (Robin) , Bone Dust , Bowl Big (Laopala) , Bowl Small(Laopala) , Brass Chain (Good Quality) , Brass Tub (For Flower) 12” , Brass Tub (For Flower) 14” , Brick , Brick , Broom Stick , Brown Cades (Ajanta) , Brown Target Paper (4’X4’) , Brush For Painting(3 Inch) , Brush For Painting(4 Inch) , Brush Holder , Cutter Machine Blade (Grinder) , Cutter Machine (Grinder) , China Nail 1.5 , China Nail 2 , China Shadle 20Mm , China Shadle 6Mm , Chisel 6 , Chitkani Alluminium 4, 6 , Chitkani Iron 4, 6 , Chopper (01 Ft) , Citronella 100 Ml , Clamp For Pvc Pipe , Cloth Clip , Commode (Hindware) , Coir Foot Mat 24 X 48 , Coir Foot Mat 12 X 36 , Carrum Board Stand G.I Pipe , Carbon For Drill Machine , Car Portable Fire Extinguisher , Car Perfume With Machine , Car Freshener , Car Duster , Camouflage Vest , Comfort 1 Letter , Cane Lathi 3 , Cane Busket , Carbolicacid 100 Ml , Casarol (Cello) 5 Ltrs , Curpet Jute , Carpet Nylon , Carrom Board 48 Good Quality , Carrom Board 52 Good Quality , Cement (Ambuja) -50 Kgs. Bag , Cement Piller 6 Ft. , Ceremonial Dress- (Hackle, Komor Bandh, Jhalar, Neck Bandh, Anklet, Leather Belt) , Lance 8 Ft. , Ceremonial Pagri , Chaki & Belna , Chalk-Pencil , Clip , Clip Board , Coal –Tar , Coasters , Coir String , Colinspray -500 Ml , Compas , Connector Pipe , Corner Flag (Best Quality) , Corner Self 8”X 8” , Corrugate Sheet2.5’X10’(Jindal) , Corrugate Sheet2.5’X12’ (Jindal) , Cordless Calling Bell Remote Battery , Cordless Calling Bell (Havells) , Cordless Microphone Battery , Cow Dung , Cricket Bat Duse , Cricket Bat Tennis , Cricket Elbow Guard (Ss) , Cricket Helmet Duse (Ss) , Cricket Pads (Ss) , Cricket Thigh Guard (Ss) , Cricket Wicket , Curpet Nylon (Belgium) , Curtain Pipe 2/3 Dia , Curtain Best Quality , Curtain Medium Quality , Curtain With All Equipment , Face Mask (Sergical) , Face Mask (Cloth) , Drum Stick , Drum For Police Band 28 , Drum For Police Band 22 , Drill Bit Set , Iron , Drill Bit Set , Wooden , Drill Bit Set , Concrete , Door Skin 4 X 7 , Drum Belt 22 , Door Hasbolt (Isi) , Door Handle Lock (Godrej) , Display Board (4 X 5) , Discuss Plate , Dinner Spoon Steel , Diathin 500 Gm. , Diamond Blade , Daw (Cutter) , D.A.P Fertilizer , Dendrite 100 Gm , Dettol Liquid -500 Ml , Dettol Liquid Hand Wash 200 Ml , Dettol Soap -75 Gm. , Dinner Set (Laopala) , Dinner Plate (Laopala), Full Plate , Dinner Plate (Laopala), Halfplate , Dinner Set Big Size(Laopala) , Discus -1 Kg (Nelco) , Discus -2 Kg (Nelco) , Door Chitkeni , Door Closer (Isi) , Door Handle , Door Kabja , Door Matcoir , Door Mat Iron Net , Door Mat Synthetic , Door Reparing With All Fitting , Drain Brush , Drain Brush With Lathi 6 , Drill Machine Set , Dustbin Plastic Big Size , Duster , Electric Welding Machine (Portable) , Electric Portable Spray Painting Machine , Electric Jhalai Rod (Steel) , Electric Jhalai Rod (Iron) , Electric Toster (Big Size) , Eb Alto Saxophone , Ear Plug , Earthenflower Tub (14) , Ezee 500 Ml , Dettol Hand Sanitizer 60 Ml , Dettol Hand Sanitizer 05 Letter Jar , Emari Paper , Empty Cement Bag , Empty Oil Dram 200 Ltrs. , Exhaust Fan (Havels) Medium Size , Exhaust Fan (Havels) Small Size , Flute Trumped (Bansi) For Band , Flower Tub (Cement) , Flower Stand With Flower ( Artificial) , First Aid Kit (Oxum Spray , Bandage 2 , Micropore Tape 1 , Band Aid 5 Pc , Volini Spray 15 Gm. ) , Fevicol/Ddl , Fire Extinguisher Bucket , Figuer 11 Target Paper .38 Revolver , Fire Extinguisher Bucket Stand (Iron) , Fire Extinguisher Cylender , First-Aid Box With All Equipments , Flag Rope (Cotton) , Flush Cock (Corsa) , Flask (Milton) Thermo Steel Carafe -1500 , Flask (Milton) Thermo Steel Carafe -1000 , Floor Tiels ( Best Quality) , Floor Tiles ( Vetrified) New Suppling And Fitting , Floor Wiper(Best Quality) , Floor Wipersponj (Best Quality) , Flower Vass (Best Quality) , Foot Ball (Cosco, Atlanta) Size-5 , Foot Ball (Cosco,Milano) Size-5 , Foot Ball Boot (Rahul) , Foot Ball Hose , Foot Ball Net Nylon , Freshmatic Automatic Spray (Air Wick) 250 Ml , Phooljharu , Funnel(Plastic) Big , Funnel(Plastic) Medium , Ground Sheet ( Satranji) 24 / 30 Ft , Ground Sheet ( Satranji) 18/24 Ft , Glucometer , Gloves Fire (Extinguisher Rubber) , Gloves For Sweeper , Gloves For Goal Keeper , Gas Oven Regulator , Gas Oven Hose Pipe , Gas Oven (18 X 18) , Gas Oven (12 X 12) , G.I. Bucket (Tata) 10 , G.I. Bucket (Tata) 12 , G.I. Bucket (Tata) 14 , G.I. Nouka / Rice Tub , G.I. Pipejoin Socket 2” , G.I. Pipe 1Dia (Tata) , G.I. Pipe 1.5Dia (Tata) , G.I. Pipe 2Dia (Tata) , G.I. Pipe 2.5 Dia(Tata) , G.I. Pipe 3 Dia(Tata) , G.I. Pipe Join Socket 1.5”Dia (Tata) , Gaita (Tata) , Gamaxin Power , Garbage Bags (Big Size) , Gardenumbrella - Standard Size , Garden Scissor , Glucose- 150 Gm , Good Knight Liquidator , Good Knight Liquidator Machine , Grass Brush , Grass Cutter Machine , Grey Paper , Ground Decoration Flag (Aney Collour) , Half Pant (Black) , Half Pant (White) , Hit Spray Red 400 Ml. , Hit Spray Black 400 Ml. , Hawkins Pressure Cooker 20 Ltr. , Hawkins Pressure Cooker 10 Ltr. , Hammer 02 Kg. , Hammer 200 Gm. , Hammer 100 Gm. , Hacksaw Blade (Double Head) Bipco , Hacksawblade(Isi) , Hacksaw Frame (Isi) , Hammer Iron 5 Kg , Hammer Wooden , Hand Shower (Jaquar) , Hand Towel (Bombay Dying) , Handel Wooden For Gita , Hanger (Best Quality) , Harpic- 500 Ml , Hand Gloves Cotton Full , Hassian Cloth , Hasua –Medium , Hand Held Scarch Light (Dragon Type) , Helmate Repairing With Painting , Hot - Pot Big Size (Cello) , Hot- Pot (Milton) 4 Bati , Iron Hook 4 , Iron Grill , Iron Brush Without Handle 6 , Inverter 850W (Microtech) , Induction Cooker (Prestige, 2000 Watt.) , Induction Cooker , Induction Cooker (Havels Insta Cook-Stx, 2000 Watt.) , Iron Angle (Tata) All Kinds , Iron Banti , Iron Brush , Iron Chanta , Iron Chimta , Iron Cot Paint , Iron Cot Repair With Paint , Iron Hamal-Dista (Medium) , Iron Hata (Medium) , Iron Karai (Medium) , Iron Khunti , Iron Khurpi , Iron Korai (Tata) , Iron Peg For Tent Complete , Targetfor Practice Firing 4’X4’ With Stand (Rifle) , Iron Tawa , Immers Rod , Judo Mat , Javelin, Metal (Nelco) , Jet Pump 1 H.P With All Fitting Articles (Kriloskar/Compton Greaves) , Jhul Jharu , Jute , Kurl-On (Mattress) 6 X 7 , Kurl-On (Mattress) 5 X 7 , Kurl-On (Mattress) 3 X 5 , Kural , Khurpi , Khurni , Khanjani Big Size , Kabja With Screw 2/4/6 , Khunja (Earthen) , Large Screw Driver (Taparia) , Lal Saloo , Ladder Aluminium ( 8 Size) , Lawn Movers (Joy Bharat) , Lawn Tennisracket (Head, Model No-Metalix) , Lawn Tennis Ball (Head, Model-Champainship) , Lawn Tennis Net With Accessries (Spotiva Tennis Net) , Lawn Tennis Racket (Head, Model-No-Pct Ti Two) , Letterpancha-Z (Small) , Letter Pancha-Z (Big) , Lifebuoy Handwash (215 Ml.) , Loud Hailer (Ahuja) , Lime Dust (Mahabir) , Lime Stone(Mahabir) , Lyzol -500 Ml , Lyzol -1L , Lock With Key (Godrej)-6-Lever , Lock With Key (Godrej)-7-Lever , Lock With Key (Godrej)-8-Lever , Mosquito Net (Best Quality) Single Bed , Mosquito Net (Best Quality) Double Bed , Mixer Grinder Best Quality , 750W , Mirror With Back Side Ply (18 X 24 ) , Mirror With Back Side Ply (18 X 60 ) , Mike Complete Set Ahuja , Microphone Cord With Jack 8 Approx , Micro Oven Samsung 21 Ltr. , Mess Tin (Alluminium) , Macheti Anti Grass (500 Ml.) , Measurement Stand, Hight 8 Ft (Olimpia) , Measurement Tape 5 Ft , Measuring Tape (15 Mtrs) , Measuring Tape (30 Mtrs.) , Measuring Tape (50 Mtrs.) , Microwavable 1.7 Ltrs. Mixingbowl (Borosil) , Microwavable 2.5 Ltrs. Mixingbowl (Borosil) , Micro Oven Glass Bowl, Big (Borosil) , Micro Oven Glass Bowl, Medium (Borosil) , Micro Oven (Model-Samsung-73 Adb) , Mike Stand (Ahuja, Dgn) , Mirror (Best Queality) , Mixture Fertilizer , Mixture Glinder (Bajaj) , Mixture Glinder (Philips - Hl 1643/04, 600 Watt.) , Good Knight Coil , Mosquito Protect Net (Best Quelity) , Moulded Chair With Out Handel(Supreme) , Moulded Chair With Handel (Supreme) , Moulded Table (Supreme) , Muratic Acid 500 Ml. , Neosporin , National Flag (2X3) Khadi , National Flag (2X3) Silk , National Flag (4X6)Silk , National Flag (4X6) Khadi , National Flag Rope , Number Punch 0-9(Big) , Number Punch 0-9(Small) , Putting , Pvc Tarpauline 10 X 10 , Pvc Tarpauline 20 X 20 , Polythene Sheet 18 X 24 Best Quality , Polythene Sheet 18 X 18 Best Quality , Polythine Pipe 3/4 (Hindi) , Polymer Door (3 X 6.5) , Plus Taparia (10) , Plus Taparia (8) , Plastic Sheet (Best Quality) 7 X 3 , Plastic Mug (Cello) , Plastic Jhuri (Basket) , Plastic Bucket 20 Ltr (Cello) , Plastic Bucket 16 Ltr (Cello) , Plaster Paris , Plastic Table Cloth , Plank Lamp - Pati All Size , Plank Gamari All Size , Pillow Kurl-On , Palmet Curtain Bracket , Palmet Clip , Paint J&N All Colours , Pvc Floor Mat , Pumper , Plastic Sheet (Good Quality Black ) 8 X 10 , Over Head Shower With Ring , Odomos , Odonil , Olympic Torch (Best Quality) , Ors -100 Gm , Paint Black (Asian) , Paint Blue (Asian) , Paint Brown (Asian) , Paint Blue, Wheather Coat (Asian) , Paint Sky Blue (Asian) , Paint Green (Asian) , Paint Primer (Asian) , Paint Red (Asian) , Paint Silver Oxide/Aluminium (Asian) , Paint Terracotta, Wheather Coat (Berger) , Paint White (Asian) , Paint White ,Wheather Coat (Asian) , Paint Yellow (Asian) , Patching Paper , Piller Cock (Jaquar) , Pillow (Good Quality) , Pillow Cover (Bombay Dying) , Plastic Bucket (14) , Plastic Bucket (16) , Plastic Gamla (20 Ltrs.) , Plastic Jug , Plastic Mug Big Size , Plastic Tea Table (Supreme) , Polythin Pipe (Water Transfer) 100 , Potash , Pressure Cooker (Hawkins) -5 Ltrs. , Projector Screen , Pvc Ring , Pitambari 100 Gm. , Ruller For Colour , Rucksack , Rope Nylon Thick , Room Heater Blower (Bajaj) , Room Heater (Bajaj) Single Coil , Room Heater (Bajaj) Double Coil , Room Freshiner (Godrej) , Rifle Cleaning Oil , Revolver Figure Target Paper (Head) , Revolver Figure Target Paper (Body) , Reed Eb Alto Saxophone , Reed Bd Clarinet (Reco 3 1/2) , Rack (Wooden) A.K.-47 , Rack (Wooden) S.L.R , Rat Killer (Mortein) , Red Oxide , Revolver Full Target Paper 4’X4’ , Rice Light , Rogger 250 Ml. , Ropefor Tag Of War/ Monkey Rope , Rope Nylon 10 Mm , Rin Ala Liquid 500Ml , Round Cover , Swimming Costume , Sunmica Sheet , Sufala Fertilizer , Stop Watch Digital , Steel Curtain Bracket , Steel Cahin (4Mm X 4.56) , Steel Cahin (4Mm X 5) , Spoon With Spoon Stand , Small Umbrella , Skipping Rope , Sofa (Triple Seat) Steel , Sofa (Single Seat) Steel , Seris Paper For Iron & Wood , Sanitizer 100 Ml , Sand , Sand , Sandwich Meker (Morphy-Richards-Sm 3001,750W) , Saucepanwith Lid (Vinod, 1.5 Ltrs. ) , Saucepanwith Lid (Vinod, 3 Ltrs. ) , Saxophone Reed , Softic Halmet With Visor , Softic Halmet , Scotch Brite , Service Protector , Shaval , Shot Put -16 Pound (Nelco) , Shower (Jaquar) , Shuttel Cock (Mousumi, Association No -1) , Side Dram Synthetic Cover (Small Size) , Side Dram Synthetic Cover (Big Size) , Sil And Nora (Small) , Sil And Nora (Big) , Sink (Still) 16”/18”/20”/22” , Sink Cock , Spade (Tata), With Handle , Spade Handle , Spray Machine ( 16 Ltrs) , Sprinkler , Stainer 100 Ml , Steel Bati (Medium) , Steel Bati Plate (Medium) , Steel Dabu Hata , Steel Frok , Steel Gamla (Medium) , Steel Glass , Steel Handi (Medium) , Steel Jhanjra , Steel Jug , Steel Khunti , Steel Pan Spoon , Steel Panja Hata , Steel Pipe For Contingent Flag Bearer , Steel Plate , Steel Sabji Dani , Steel Dustbin (Mediun) , Steel Spoon , Steel Thala , Steel Water Drum (With Tap) 50 Ltr. , Stone Chips , Stop Watch (Racer) , Stove Kerosine (Tata) , Surf Excel Blue (500 Gm) , Surf Excel Bar 250 Gm , Sutli , Syntex Pvc Door , Track Suit Set Best Quality , Towel Big(Bombay Daying) , Tea Table Steel With Glass , Table Cloth Blue / Merun (6 X 4) , Table Cloth (Ordinary) , Table Glass 10 Mm (Best Quality) , Table Glass 12 Mm (Best Quality) , Table Glass 6 Mm (Best Quality) , Table Glass 8 Mm(Best Quality) , Target Paper 4 X 4 , Tea Table Wooden 2’X3’ , Tarpelt (Tata) , Tarpin Oil , Tea Container (Thermoflax Steel Body) , Tea Spoon Steel , Tea Cup With Plate (Laopala) , Tea Set (Bone China) , Table Wooden 3’X 2’ , Tennis Ball (Sixer) , Three Way Bib Cock , Tissue Paper , Tiffin Carier 3 Box (Milton) , Toaster (Bajaj Majesty Atx-9, Auto Pop Toaster, 800 W) , Toilet Brush (Wooden) , T -Flag (Both Side Embroidery) , Towel Handle (Best Quality) , T -Flag Silk (Different Colour) , Towel Rod 18” , Towel Rod 24” , Towel Stand , Towel White (Primium) , Tray (Best Quality) , Trey Melamine (Serve Well) , Tuli 0 To 5 Size , Urinal Complete Set (Best Quality) , Urinal Complete Set (Ordinary) , Ujala -100 Ml , Umbrella - Standard Size , Unit Flag (3 X 2 ) Silken , Unit Flag (6 X 4 ) Silken , Unit Flag With Logo & Embrodery Work (2’X3’) , Unit Flag With Logo & Embrodery Work (4’X6’) , Urea , Urinal Pan (Hindustan) , Use Me With Padle (Dustbin) Medium Size , Use Me Without Padle (Dustbin) Medium Size , Volini Spray , Vip Tray (Fibre) , Vinyl Board With Sticker , Velvet , Vest With Collour (Any Collour)-Full Sleeved , Vest With Collour (Any Collour)-Half Sleeved , Vim Liquid-250 Ml , Vimbar Soap -300 Gms. , Vinyl Flooring , Volley Ball (Cosco, Aclean ) , Volley Ball (Cosco, Super Volley) , Volley Ball (Nivia) , Volley Ball Net Nylone (Falcon) , Window Net Nylon Complete Setting , White Pt Vest (Best Quality) , White Canvas Shoes (Khadim / Elite) , White T-Shirt Half (Best Quality) , White T-Shirt Full (Best Quality) , Water Pump 1.5 Hp (Crompton) , Water Heater Connector Pipe , Water Drum Plastic With Lid 50 Ltrs , Water Drum Plastic With Lid 80 Ltrs , Water Drum Plastic With Lid 120 Ltrs , Water Container With Tap , Wall- Clock Ajanta , Wall Bit , Wall Hangar (Plastic) , Wall Hangar (Steel) , Wall Putty (20 Kgs. Bag) , Wall Tiles New Supplying And Fitting , Washing Brush (Cloth) , Water Drum (Pvc) 100 Ltrs. , Water Drum (G.I.) 100 Ltr. , Water Drum (G.I.) 200 Ltr. , Water Purifier 08 Letter (Kent) , Water Glass(Borosil) , Water Jhari- 5 Ltr. , Water Tank (1000 Ltrs)Sintex , Water Tank (500 Ltrs)Sintex , Water Tank (750 Ltrs) Sintex , Weight Machine (Digital) , Whitetable Cloth , White Board 3 X 4 , White Board Stand , White Cades (Ajanta) , White Cement- 50 Kg (Acc) , White Cloth (4’X5’) , White Cotton Bed Sheet (5’X7’) , White Phenyle (Cross) , White Shocks -(Anchor) , Window Repairing With All Fitings , Woodenhigh Bench1.5’X9’ (9 Ft) , Wooden Ladder 10 , Wooden Ladder 20 , Wooden Table (3’X4’) , Wooden Low Bench1.5’ X 9’(9 Ft) , Yoga Mat , Nonlit Board Fabricationalong With Flex Printing Without Structure , Nonlit Board Fabrication And Installation Along With Flex Printing With Iron Structure , Glow Sign Board Fabrication Along With Flex Printing Without Structure , Glow Sign Board Fabrication And Installation Along With Flex Printing With Iron Structure , Flex Printing For Glow Sign Board , Flex Printing For Nonlit Board , Flex Change (Without Flex Printing)Choke, Strarter & Wire , Flex Change (Without Flex Printing) , Sandwich Clip , 2 X 2 Angle , 1.5 X1.5 Angel , 1X 1 Angel , 2 X 2 Angle , 2.5 X 2.5 Angle , Ply Wood 2Mm , Ply Wood 6Mm , Ply Wood 8 Mm , Ply Wood 12 Mm , Ply Wood 4Mm , Brass Ball 1’ , Ball Valve , Ball Valve Handle , Elbow“R”1”X1/2” , G.I “ T”1’ X 1/2’ , G.I “R”Socket1’ X 3/4” , G.I “T” 1’ , G.I Elbow ½” , G.I Elbow 1’ , G.I Elbow¾” , G.I Nipple ½”X2” , G.I Nipple1”X2”X3”X4” , G.I Pipe ½” , G.I Thed 1’X6’ , G.I Union¾” , G.I Union1’ , Hole Tite , Hook¾ , Pvc 80 Cdh Pipe1” , Pvc Pipe 1/2 , Pvc Pipe 1 , Pvc Pipe 3/4 , Pvc Pipe 1.5 , Pvc Pipe 2 , Pvc Elbow 1/2 , Pvc Elbow 1 , Pvc Elbow 3/4 , Pvc Elbow 1.25 , Pvc Elbow 1.5 , Pvc Elbow 2 , Pvc Tee 1/2 , Pvc Tee 1 , Pvc Tee 3/4 , Pvc Tee 1.25 , Pvc Tee 2 , Pvc Union 1/2 , Pvc Union 1 , Pvc Union 3/4 , Pvc Union 1.25 , Pvc Union 2 , Pvc Claim , Gate Valve 25 Mm(Isi) , Gate Valve 10 Mm (Isi) , Foot Valve 25 Mm (Isi) , Foot Valve 10 Mm (Isi) , Jum Nut (Isi) , ‘J’Type Hook (Isi) , Nut Washer 1Inch , G.I. Socket 1 , G.I. Socket 1/2 , G.I. Socket 3/4 , G.I. Elbow 4 X 1/2 , G.I. Nipple 9 , G.I. Nipple 12 , G.I. Nipple 18 , G.I. Nipple 3/4 , G.I. T 3/4 X 1/2 , G.I. T 3/4 , G.I. T 1/2 , G.I. R Socket 1/2 X 3/4 , Anglow Stop Cock 1/2 , Solven , Tank Nipple , Bush , Welding Rod (Iron) , Welding Rod (Brass) , Fevicol Heatx , Fevicol Addisive , Door Stoper With Magnetic , Jersey For Football (Best Quality) , Jersey For Cricket (Best Quality) , Trophy For Winner (Best Quality) , Trophy For Runner (Best Quality) , Mementoes (Best Quality) , Trophy For Man Of The Match/Series (Best Quality) , Jersey(Cotton) With Printing , Jersey(Cotton) With Out Printing , Water Bottle , Ac Starter Set (Havels) , Bedswitch (Anchor) , Black Tape(Big Size) , Bulb 100 Watt (Philips) , Bulb 200 Watt (Philips) , Bulb 60 Watt (Philips) , Bulb Buttam Holder , Bulb Holder Angel (Anchor) , Bulb Holder Pendent (Anchor) , C.F. L. Lamp -11 Watt (Philips) , C.F. L. Lamp -5 Watt (Philips) , C.F. L. Lamp -8 Watt (Philips) , C.F. L. Lamp -14 Watt (Philips) , C.F. L. Lamp -18 Watt (Philips) , C.F. L. Lamp -23 Watt (Philips) , C.F.L. Lamp -32 Watt (Philips) , Led 09 Watt (Philips) , Led 12 Watt (Philips) , Led 15 Watt (Philips) , Led 45 Watt (Philips) , Cable4 Mm -2 Core ((Havels) , Cable6 Mm - 4 Core ((Havels) , Cashinggang Box -3 Way , Cashing Gang Box -2 Way , Cashing Gang Box -4 Way , Cashing Gang Box -5 Way , Cashing Gang Box -6 Way , Cashing Gang Box -8 Way , Casing1/2 , Casing3/4 , Ceiling Fan (Oriant)Size-48 , Ceiling Fan (Usha) Size-48 , Ceiling Rose (Anchor) , Ceilling Hanging Light , Change Over 63 Amp 4 Pole (Havels) , Change Over - 32 Amp (Anchor) , Cord Less Calling Bell (Havels) , Codenser For Fan , Calling Bell With Cord (Philips) , Calling Bell Without Cord (Philips) , Cover2 Model (Cabtree) , Cut Out -10 Amp (Anchor) , D.P Main Switch32 Amp (Anchor) , Dalda Pipe , Earthin Pipe , Earthin Rod , Earthin Wire , Elbowl (Pvc) , Elbowt (Pvc) , Electric Iron (Bajaj) , Emergency Light With All Equipments (Sigma) , Extension Board , Fan Hook , Flexible Wire (Star Line) , Fuse- 5 Amp (Anchor) , Fuse-63 Amp (Jj) , Full Thred Screw , G.Ishaddle 1/2 , G.I. Wire , Globlight Set (Best Quality) , Halogen Holder -1000 Watt(Philips) , Halogen Holder- 500 Watt(Philips) , Hellogen- 1000Watt Glass (Philips) , Hellogen- 1000 Wattfilament (Philips) , Hellogen 500 Wattfilament (Philips) , Hellogen- 500 Wattglass(Philips) , Hellogen Light Complete Set 500 Watt (Philips) , Indicator Lamp , Rechargeable Battery For Hhmd , Led Tube Light Complete Set 20 Watt(Havels) , Main Switch63 Amp (Havels) , Main Switchchange Over63 Amp (Havels) , Main Switch 32 Amp (Jj) , Main Switch 16 Amp (Jj) , Main Switch 63 Amp Tpn (Hpl) , Male - Female (Jj) , Mcb Box (Different Type) , Mcb Switch -10Amp (Havels) Singel Pole , Mcb Switch -16Amp (Havels) Singel Pole , Mcb Switch -32Amp (Havels) Singel Pole , Mcb Switch-63Amp (Havels) Singel Pole , Nail , Night Bulb (Philips) , P.V.C. Multigagewire -.75 Mm(Havels) , P.V.C. Multigagewire -1 Mm(Havels) , P.V.C. Multigagewire- 1.5 Mm(Havels) , P.V.C. Multigagewire -2.5 Mm (Havels) , P.V.C. Multigagewire- 4Mm(Havels) , P.V.C. Multigagewire -6Mm(Havels) , P.V.C. Multigagewire -8 Mm(Havels) , Pedestal Fan(Havels)Size-16 , Pedestal Fan(Usha)Size-16 , Pedestal Fan(Orient)Size-16 , Pliers (Taparia) , Pvc Gujji , Regulator For Fan (Usha) , Rise Light Led , Pixel Light Led , Pixel Led Smps , Pixel Led Controller , S. S Combined Set (Anchor) With Box , Screw (1) , Screw (1.5) , Screw (2) , Screw (3”/4) , Socket - 5 Pin (Anchor) , Socket 15 Amp (Cabtree) , Socket 3 Pin (Anchor) , Socket 5 Amp (Cabtree) , Socket Piano -15 Amp (Havels) , Socket Piano- 5 Amp (Havels) , Socket Type Regulator (Anchor) , Socket Type Regulator (Cabtree) , Stabiliser 250 Watt (Neutron) , Starter (Cabtree) , Steel Saddle , Search Light (Rechargeable) , Strep Light Led With Adaptor , Switch 15 Amp (Anchor) , Switch 5 Amp (Anchor) , Switch 5 Amp (Cabtree) , Switch Type Regulator (Anchor) , Single Pole Mcb 32 Amp(Havels) , Top 2 Pin (Jj) , Top 3 Pin (Jj) , Top 15 Amp (Havels) , Top 5 Amp (Havels) , Top -5 Pin (Jj) , Tube Light Buttom , Tube Light Choke (Circuit) Havels , Tube Light Choke (Philips) , Tube Light Clamp , Tube Light Complete Set 28 Watt 4’(Havels) , Tube Light Complete Set 20 Watt (Havells) , Tube Light Lamp Yellow (Philips) 36 Watt. , Tube Light Holder , Tube Light Lamp- T-5 (Havels) , Tube Light Lamp (Havells) 36 Watt. , Tube Light Lamp 28 Watt(Havels) , Tube Light Starter (Philips) , Tube Light Complete Set 2 X 36 Fitting Box Type , Two Pin Plug (Jj) , Vapour Lampignator 250 W (Philips) , Vapour Lamp Bulb 400 Watt (Havels) , Vapour Lamp Choke 250 Watt (Philips) , Vapour Lamp Choke 400Watt (Havels) , Vapour Lamp Complete Set 250 Watt (Havels) , Vapour Lamp Complete Set 400 Watt (Havels) , Vapour Lamp Condencer 250 Watt(Philips) , Vapour Lamp Condencer 400 Watt(Havels) , Wall Catch Light Set (Havels) , Wire -2 Core (Starline) , Wodden Gujji , Wooden Biscuit (Sunmica)
Contract Date: May 30, 2025 Contract Value : 1.40 Crore
Statutory Bodies & Commissions/Committees No of Bidders 4
West Bengal View Result →
9.
Educational and Research Institute #10887186 Technical Bid
Tender for Servicing Of And Maintnance Of Kitchen Equipment At Hostel Mess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
11.
Power #10732056 Price Bid
Work Of 11 Kv, 33 Kv Cable, 33 Kv Switchyard And Others Work Under Business Plan 2025-26 In The Area Of Jurisdiction Of Edd-Pilkhuwa Under Edc-Hapur. (44 No. Works)- 2 Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit 3 Cable Box 3X185 O/D Sqmm 11 Kv 4 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake 5 11 Kv Fuse Set 6 Pcc Pole 8.5 Mtr Long. 7 11 Kv Pin Insulator Polymer 8 11 Kv Disc Insulator Polymer 9 M.S. Channel 100X50X50 Mm 10 Earthing Complete 11 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit 12 11 Kv O/D Xipe 3X300 Sqmm C/J Kit 13 11 Kv Through 3X185 Sqmm Xlpe C/J Kit 14 33 Kv Circuit Breaker 800A, 750 Mva 15 Acsr Dog. Conductor 16 Cable Ht Xipe 3X300 Sqmm 33 Kv 17 Cable Box 3X300 O/D Sqmm 33 Kv 18 H/S 33 Kv 3X300 Sqmm J/Kit St. Th 19 Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. 20 11 Kv Vcb Incoming 21 33 Kv Pt Outdoor (2Set) (2X3=6) 22 Battery Set 24 Volt 23 Battery Charger 24 Volt 24 33 Kv Ct 400/200/1 Amp 25 33 Kv Ct 200/100/1 Amp 26 33 Kv Control Pannel Double T/F 27 33 Kv Fuse Set 28 Earth Wire 7/14 Swg 29 Earth Rod 2540X20 30 Eraction And Fixing And Making Connection Of Following Material (As Per Respo Norms) At Diffrent 33/11 Kv Substation Were Include Making Alignment, All Required Nut Bolt, Clamps, Lug, Connector, Wire And Strip Etc All Labour,T&P, Safe & Porper Oprations Provided By Contractor In All Respects. 31 Cable Ht Xlpe 3X185 Sqmm 11 Kv With Double Circuit 32 Cable Box 3X185 O/D Sqmm 11 Kv 33 11 Kv Vcb For Outgiong Ctr 200/100/5A 350 Mva (1250 Mva) Steelmake 34 11 Kv Fuse Set 35 Pcc Pole 8.5 Mtr Long. 36 11 Kv Pin Insulator Polymer 37 11 Kv Disc Insulator Polymer 38 M.S. Channel 100X50X50 Mm 39 Earthing Complete 40 11 Kv Xipe Cable 3X300 Sqmm With Double Circuit 41 11 Kv O/D Xipe 3X300 Sqmm C/J Kit 42 11 Kv Through 3X185 Sqmm Xlpe C/J Kit 43 33 Kv Circuit Breaker 800A, 750 Mva 44 Acsr Dog. Conductor 45 Cable Ht Xipe 3X300 Sqmm 33 Kv 46 Cable Box 3X300 O/D Sqmm 33 Kv 47 H/S 33 Kv 3X300 Sqmm J/Kit St. Th 48 Cable H.T.Xlpe 11 Kv 3X300 Sq.Mm. 49 11 Kv Vcb Incoming 50 33 Kv Pt Outdoor (2Set) (2X3=6) 51 Battery Set 24 Volt 52 Battery Charger 24 Volt 53 33 Kv Ct 400/200/1 Amp 54 33 Kv Ct 200/100/1 Amp 55 33 Kv Control Pannel Double T/F 56 33 Kv Fuse Set 57 Earth Wire 7/14 Swg 58 Earth Rod 2540X20 59 Providing, Supplying, Laying And Installation Of Hdpe Pipe Of Pe-80 Grade, Pn-6, 200 Mm Diameter By Horizontal Directional Drilling (Hdd) / Trenchless Method For Accommodating 11 Kv, 3×185 Sq.Mm Xlpe Insulated, Armoured Cable, Including Execution Of Road Crossing Or Similar Crossings Wherever Required, Complete With Pilot Drilling, Reaming And Pullback Operations, Proper Jointing Of Hdpe Pipe (Butt Fusion/Electrofusion), All Labour, Tools & Plants, Machinery, Drilling Fluid, Safety Arrangements, Formation Of Entry And Exit Pits And Site Restoration; The Contractor Shall Be Fully Responsible For Obtaining Necessary Permissions, Protection Of Existing Utilities And Resolution Of All Right Of Way (Row/Raw) Issues During Execution. 60 Earthing Of 125 Nos 11 Kv La Sets On DtS Supports With Ms Earth Rod Of (20X2500)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of 25Mm X 3Mm Gi Strip & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts And Required 25Mm X 3Mm Gi Strip As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. 61 Providing The Material And Execution Gi Pipe Earthing With 40 Mm Dia B Class Gi Pipe 80 Feet Boar To Water Level For Proper Earthing ( Earthing Resistance Less Than Or Equal To 1 Omh ) At 33/11 Kv Substation With The Help Of 50Mm X 6Mm Gi Strip Duly Welding To Dt Transformer Other Equipment. With Earthing Mess Lug, Nut And Bolt. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor. All Labour, T&P Will Be Provided By Contractor In All Respects. 62 Providing, Supplying And Fixing Of Copper Bus Bar Of Size 80 Mm × 10 Mm Suitable For 11 Kv Vcb Panel, Including Cutting, Drilling, Bending, Proper Alignment, Insulation Clearance, And Secure Fastening With All Required Nuts, Bolts, Washers And Supports, Ensuring Proper Electrical And Mechanical Connections, Complete In All Respects; The Work Shall Include All Labour, T&P Will Be Provided By Contractor In All Respects. 63 Grouting Of Following Pcc Pole 8.5 Mtr. Long Supports In Cc 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With Cc 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. 64 Providing And Fixing Of Pg Clamps (Parallel Groove Clamps) Of Suitable Sizes For Making Conductor-To-Conductor Connections, Including Dog Conductor To Dog Conductor And Panther Conductor To Panther Conductor Joints, Complete With All Necessary Nuts, Bolts And Accessories, Ensuring Proper Electrical And Mechanical Continuity, As Per Relevant Standards And Directions Of Site Incharge All Labour, T&P Will Be Provided By Contractor In All Respects. 65 Providing And Fixing 11 Kv Relay, With (E/F & O/C) Of C&S, Ashide, Abb Make With 1&5 Amp Port Suitable For 11 Kv Feeder Pannel As Per Respo/Norms And As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor With All Labour, T&P In All Respects. 66 Providing And Fixing Of Wti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti , As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. 67 Providing And Fixing Of Oti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti, As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. 68 Providing And Fixing Of 11 Kv Lighting Arrester With 11/0.4 Kv Dt And Make Connection (25Mm X 3Mm Gi Strip Will Uniform Fixing Of Lighting Arrester With Transformer) 69 Providing And Fixing Of Vaccume Interupter In 11 Kv Pannel, As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects. 70 Providing And Fixing 33 Kv Ct Stracture As Per Respo/Norms And As Per Direction Of Site Inchagre Work Includs Grouting Stracture And Making Plinth As Per Norms All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
12.
Power #10732055 Price Bid
Tender for Carriage Of Following Material Of Estimate, From Electricity Store Center, Hapur To Site Of Work With Loading, Unloading Multiple Handling, Staking,Labour,T&P And Transpotation At Both Ends On Kachha/Packka Road, As Per Direction Of Site Incharge From Je Store/Store Center Hapur/Ghaziabad/Bulandshar (0-50 Km) Complete In All Respects. , 33 Kv Pt , 33 Kv Lightning Arrester , Battery Set , Battery Charger , 33 Kv Ct , 33 Kv Control Panel Single T/F , 33 Kv Isolator , 33 Kv Fuse Set , Lt Xlpe Cable 1X240 Sqmm , 33 Kv Control Panel Double T/F , Earth Rod 2540X20mm , Eraction And Fixing And Making Connection Of Following Material (As Per Respo Norms) At Diffrent 33/11 Kv Substation Were Include Making Alignment, All Required Nut Bolt, Clamps, Lug, Connector, Wire And Strip Etc All Labour,T&P, Safe & Porper Oprations Provided By Contractor In All Respects. , 33 Kv Pt , 33 Kv Lightning Arrester , Battery Set , Battery Charger , 33 Kv Ct , 33 Kv Control Panel Single T/F , 33 Kv Isolator , 33 Kv Fuse Set , Lt Xlpe Cable 1X240 Sqmm , 33 Kv Control Panel Double T/F , Providing And Fixing 11 Kv Relay, With (E/F & O/C) Of C&S, Ashide, Abb Make With 1&5 annual periodical maintenance Port Suitable For 11 Kv Feeder Pannel As Per Respo/Norms And As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor With All Labour, T&P In All Respects. , Providing And Fixing Of Wti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti , As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Oti Meter Isi Mark For 33/11 Kv Power Transformer Work Including Making Connection Proper Opration Of Wti, As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Installation Of Maintenance Free Multifaceted Proactive And Corrosion Free Chemical Earthing ( Resistance Less Than Or Equal To 2 Omhs) Electrod Size 80Mm X 3000Mm Complete With 50Kg Backfill Compound With All Required Accessories For Body/Neutral Earthing Of Dt Transformers, Including Cost Of M.S. Earth Strip For Connection The Earth Strip (50Mm X 6Mm) Will Be Welded To The Earthing And Neutral Support With Lug And Nut Bolt, As Per Respo/Norms And As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing The Material And Execution Gi Pipe Earthing With 40 Mm Dia B Class Gi Pipe 80 Feet Boar To Water Level For Proper Earthing ( Earthing Resistance Less Than Or Equal To 1 Omh ) At 33/11 Kv Substation With The Help Of 50Mm X 6Mm Gi Strip Duly Welding To Dt Transformer Other Equipment. With Earthing Mess Lug, Nut And Bolt. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor. All Labour, T&P Will Be Provided By Contractor In All Respects. , Supply And Laying Isi Make Following Copper Control Cable With Make Connection From Control Pannel To Power Transformer Instruments All Labour, T&P Will Be Provided By Contractor In All Respects. , 4X25 Sq.Mm. , 6X25 Sq.Mm. , Laying Of Lt 1X240 Sq.Mm. Pvc Cable As Per Respo/Norms And As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Fire Exitinguisher (9Kg), As Per Direction Of Site Incharge. , Co2 Type , Abc Type , Providing And Fixing Of 33 Kv T/F Control Panal Relay, As Per Respo/Norms And As Per Direction Of Site Incharge. (Make C&S, Ashide, Abb) All Labour, T&P Will Be Provided By Contractor In All Respects. , Earthing Of 102 Nos 11 Kv La Sets On Dts Supports With Ms Earth Rod Of (20X2500)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of 25Mm X 3Mm Gi Strip & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts And Required 25Mm X 3Mm Gi Strip As Per Direction Of Site Incharge. All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of Vaccume Interupter In 11 Kv Pannel, As Per Direction Of Site Incharge. All Required Nut Bolt, Clamps, Lug, Connector Etc For Safe & Porper Oprations Provided By Contractor All Labour, T&P Will Be Provided By Contractor In All Respects. , Providing And Fixing Of 11 Kv Lighting Arrester With 11/0.4 Kv Dt And Make Connection (25Mm X 3Mm Gi Strip Will Uniform Fixing Of Lighting Arrester With Transformer) All Labour, T&P Will Be Provided By Contractor In All Respects. , Saftly Dismantling Work Properly And Carriage Of Electircal Equipment From Site Of Work To Electricity Store Center, Hapur With Loading ,Unloading , Handling And Stacking, Labour,T&P And Transpotation At Both Ends On Kachha/Packka Road, As Per Direction Of Site Incharge From Je Store/Store Center Hapur/Ghaziabad/Bulandshar (0-50 Km) Complete In All Respects. At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
13.
Defence #10670872 Price Bid
Annual Maintenance Contract Of 05 Nos Lifts Installed In Officers And Sos Mess For One Year At 165 Bn Bsf Greater Noida Under Dig Hq Fhq Bsf New Delhi , Annual Maintenance Contract For A Period Of One Year Of Following Capacity Elevators ( Lifts ) Of Thyssenkrupp Make . During The Amc Period Firm / Contractor Will Provide Trained And Qualified Employees To Provide Routine Maintenance , Examination And Lubrication Service According To The Thyssenkrupp Elevator Maintenance System For Purchasers Equipment , 12 Times A Year And Will Furnish The Necessary Lubricants And Cleaning Materials Including The Replacement Of Hydraulic Fluid And Machine Gear Oil . Firm Will Annually Test All Safety Devices In Accordance With Relevant Safety Standards With The Exception Of Full Load Testing . Throughout The Duration Of This Agreement , Firm Shall Cover Repair Or Replacement Of Machines , Motors , Generators , Ropes , Inverter Systems , And Controller Parts To Be Inclusive Of Printed Circuit Boards And Sub Components Inclusive Of Belts , Rollers , Bearings , Coils , Brake Shoes , Liners , Contactors , Contacts , Relays , Push Buttons , Indicators , Controller Chocks , Magnets And Magnetic Switches , Door Operator Motor , Door Operator Vvvf Drive Car Door Safety Device , Limit Switches , Governor , Interlocks On Hoist Way Doors And Other Minor Mechanical Parts Shall Be Included As Required At Free Of Cost . A ) 08 Passengers / 12 Stop / 1Mps / Tic-V ( Lm No . 10348 ) , Annual Maintenance Contract For A Period Of One Year Of Following Capacity Elevators ( Lifts ) Of Thyssenkrupp Make . During The Amc Period Firm / Contractor Will Provide Trained And Qualified Employees To Provide Routine Maintenance , Examination And Lubrication Service According To The Thyssenkrupp Elevator Maintenance System For Purchasers Equipment , 12 Times A Year And Will Furnish The Necessary Lubricants And Cleaning Materials Including The Replacement Of Hydraulic Fluid And Machine Gear Oil . Firm Will Annually Test All Safety Devices In Accordance With Relevant Safety Standards With The Exception Of Full Load Testing . Throughout The Duration Of This Agreement , Firm Shall Cover Repair Or Replacement Of Machines , Motors , Generators , Ropes , Inverter Systems , And Controller Parts To Be Inclusive Of Printed Circuit Boards And Sub Components Inclusive Of Belts , Rollers , Bearings , Coils , Brake Shoes , Liners , Contactors , Contacts , Relays , Push Buttons , Indicators , Controller Chocks , Magnets And Magnetic Switches , Door Operator Motor , Door Operator Vvvf Drive Car Door Safety Device , Limit Switches , Governor , Interlocks On Hoist Way Doors And Other Minor Mechanical Parts Shall Be Included As Required At Free Of Cost . B ) 08 Passengers / 12 Stop / 1Mps / Tic-V ( Lm No . 10349 ) , Annual Maintenance Contract For A Period Of One Year Of Following Capacity Elevators ( Lifts ) Of Thyssenkrupp Make . During The Amc Period Firm / Contractor Will Provide Trained And Qualified Employees To Provide Routine Maintenance , Examination And Lubrication Service According To The Thyssenkrupp Elevator Maintenance System For Purchasers Equipment , 12 Times A Year And Will Furnish The Necessary Lubricants And Cleaning Materials Including The Replacement Of Hydraulic Fluid And Machine Gear Oil . Firm Will Annually Test All Safety Devices In Accordance With Relevant Safety Standards With The Exception Of Full Load Testing . Throughout The Duration Of This Agreement , Firm Shall Cover Repair Or Replacement Of Machines , Motors , Generators , Ropes , Inverter Systems , And Controller Parts To Be Inclusive Of Printed Circuit Boards And Sub Components Inclusive Of Belts , Rollers , Bearings , Coils , Brake Shoes , Liners , Contactors , Contacts , Relays , Push Buttons , Indicators , Controller Chocks , Magnets And Magnetic Switches , Door Operator Motor , Door Operator Vvvf Drive Car Door Safety Device , Limit Switches , Governor , Interlocks On Hoist Way Doors And Other Minor Mechanical Parts Shall Be Included As Required At Free Of Cost . C ) 13 Passengers / 11 Stop / 1Mps / Tic-V ( Lm No . 10350 ) , Annual Maintenance Contract For A Period Of One Year Of Following Capacity Elevators ( Lifts ) Of Thyssenkrupp Make . During The Amc Period Firm / Contractor Will Provide Trained And Qualified Employees To Provide Routine Maintenance , Examination And Lubrication Service According To The Thyssenkrupp Elevator Maintenance System For Purchasers Equipment , 12 Times A Year And Will Furnish The Necessary Lubricants And Cleaning Materials Including The Replacement Of Hydraulic Fluid And Machine Gear Oil . Firm Will Annually Test All Safety Devices In Accordance With Relevant Safety Standards With The Exception Of Full Load Testing . Throughout The Duration Of This Agreement , Firm Shall Cover Repair Or Replacement Of Machines , Motors , Generators , Ropes , Inverter Systems , And Controller Parts To Be Inclusive Of Printed Circuit Boards And Sub Components Inclusive Of Belts , Rollers , Bearings , Coils , Brake Shoes , Liners , Contactors , Contacts , Relays , Push Buttons , Indicators , Controller Chocks , Magnets And Magnetic Switches , Door Operator Motor , Door Operator Vvvf Drive Car Door Safety Device , Limit Switches , Governor , Interlocks On Hoist Way Doors And Other Minor Mechanical Parts Shall Be Included As Required At Free Of Cost . D ) 29 Passengers / 12 Stop / 1Mps / Tic-V ( Lm No . 10351 ) , Annual Maintenance Contract For A Period Of One Year Of Following Capacity Elevators ( Lifts ) Of Thyssenkrupp Make . During The Amc Period Firm / Contractor Will Provide Trained And Qualified Employees To Provide Routine Maintenance , Examination And Lubrication Service According To The Thyssenkrupp Elevator Maintenance System For Purchasers Equipment , 12 Times A Year And Will Furnish The Necessary Lubricants And Cleaning Materials Including The Replacement Of Hydraulic Fluid And Machine Gear Oil . Firm Will Annually Test All Safety Devices In Accordance With Relevant Safety Standards With The Exception Of Full Load Testing . Throughout The Duration Of This Agreement , Firm Shall Cover Repair Or Replacement Of Machines , Motors , Generators , Ropes , Inverter Systems , And Controller Parts To Be Inclusive Of Printed Circuit Boards And Sub Components Inclusive Of Belts , Rollers , Bearings , Coils , Brake Shoes , Liners , Contactors , Contacts , Relays , Push Buttons , Indicators , Controller Chocks , Magnets And Magnetic Switches , Door Operator Motor , Door Operator Vvvf Drive Car Door Safety Device , Limit Switches , Governor , Interlocks On Hoist Way Doors And Other Minor Mechanical Parts Shall Be Included As Required At Free Of Cost . E ) 29 Passengers / 12 Stop / 1Mps / Tic-V ( Lm No . 10526 )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Uttar Pradesh View Result →
14.
Banking and Finance #10607564 Price Bid
E-Tender For Procurement Of Equipments For Siep -1 Pre- Vocational Unit 2 Children Wall Bar -n(•tThe Size should be : 85*52*168cmn•tMust be Use full for children to do standing and sitting training with the help of wall bars and muscle strength training as well as trunks traction and extension training.) 3 Children PT Stool(adjustable) -n(•tMust be use full for Used for children PT training.n•tIt must have Wheelsn•tIt should have Blue Leather Sitting) 4 Finger Correcting Board -n(•tUsed to correct fingers flection contracture and adduction malformation.n•tIt should have 4 holes) 5 Finger Correcting Board(with universal wheel) -n(•tUsed to correct fingers flection contracture and adduction malformation.n•tIt should have 3 holesn•tIt Should have 3 or 4 Wheels) 6 Hydraulic children step trainer -n(•tSize Must be: 70*56*97cmn•tWeight not more than: 29kgn•tUse full for lower limbs range of motion and muscle power training.) 7 Training Quoit -n(•tIt must be Use full for hand-eye coordination and perceptionn•tIt must be Use full Cognition training.) 8 Word cognitive puzzle –n(•tWeight not more than : 3.3Kgn•tMaterial must be: wooden) 9 Cognition Toys – n(•tSize should be: 30*30*30cmn•tWeight not more than: 8.7kgn•tShape must contain following:n-tCube 5pcsn-tCylinder 5pcsn-tTriangular 5pcsn-tCuboid 5pcsn•tIt must be use full for perception function training.) 10 Intelligence develop assembly – n(Size must be: 32.2*28.7*23.5cm) 11 PHYSIO-OCCUPATIONAL THERAPY UNIT 12 Treadmill- 2HP Noiseless AC motor 13 Short wave diathermy- 500W with valve 14 Bolsters of different sizes 15 Puzzle - Body parts with two facial expressions with box, Animal, Birds, fruits, transports, Different shapes 16 Shoulder CPM 17 Lower extremity CPM 18 CP chair 19 Static cycle 20 Bed cycle 21 weighing scale 22 texture fruit tree 23 Ball pool (48X 48) 24 perdue peg board 25 exercise mats - 6X3 26 exercise frame - rope mess, pip ladder and rock climbing board 27 Trampoline (48 Inch) 28 Quadriceps Table with detachable backrest 29 Stethoscope 30 blood pressure appratus 31 Goniometer – 180 & 360 degree 32 Electronic stopwatch 33 Digital weighting machine 34 Treatment trolley 35 Stainless steel stools 36 Tables 37 Chairs 38 Waiting chairs 39 Cupboards 40 Computer 41 Printer & scanner 42 Muscle stimulator Combo- with Current -Galvanic, Interrupted Galvanic, Faradic, Surged Faradic and TENS 43 Micro control 4 channel tens 44 Weight cuff- 1/4 kg, 1/2 Kg, 1 Kg, 1.5 kg -n(•tStrengthens weak muscles through load resisting exercises of both upper and lower limbs. n•tLead shots filled cuff is double sewn and had long wrap around straps to hold weight cuff securely in Place. n•tA full set consists of 4 color coded cuffs i.e. Capacity: 250 gm, 500 gm, 1 kg, 1.50 kg) 45 Thera band- different colors and ranges – n(•tTheraBand Rubber Latex Less Bands should be supplied with 5 feet length, 4-inch width of different colour (Yellow, Red, Green, Blue, Black) - Set of 5n•tIt should be Latex Less, No Scent, No Powdern•tColour-coded Progressive Resistance system should allow users to recognize improvement as it happens – when the patient grows stronger they can move up to the next color, for strength training and physical therapy programs. Colour-coded levels should be increasing in difficulty from Yellow to Black) 46 Thera putty with different colors & ranges – n(The system should have following parameters:n•tColours options : Tan, Yellow, Red, Green, Blue, Greyn•tWeight must be: 100grams eachnHigh Resistance Level)n 47 Portable shoulder exerciser with pronation supination arrangement 48 Grip exerciser 49 Hand Gym Kit Board –n(Laminated exercise boards with storage drawer, have several holes to fix Pegs and springs. The unit permits active flexion and extension exercises of the finger and grip.nSpecification:nHand Gymkit Board consists, One finger Disc, One Roller, Three Spring loaded Knobes, 3 pegs to support finger and 3 Sets of Springs of different tensions) 50 Wrist roll -n(The unit should have following parameters:n•tOne piece SS roll with three different diameters i.e. 30mm, 40mm and 50mm to be fitted on a laminated board n•tBoard size: 25cm x 80cm long with adjustable friction control mechanismn•tControllable from zero to maximum for flexion and extension exercises of wrist and forearm) 51 Rope pulley handle set –n(Shoulder Pulley Unit with rope adjustment system (Wall Mounting)n•tShoulder Pulley unit should provide exercises of the Elbow and shoulder. n•tTubular steel constructed unit should come with Pulleys, Nylon Rope, Handles and Wall fixing frame.n•tPulleys: Two, Nylon pulley n•tHandles: Two, spring steel wire handle with plastic grip.n Rope/Cord: Interwoven Nylon cord of suitable length.) 52 Upper extremity work station -n(should have facility of peg board, pinch tree, pipe assemble unit PVC, 25 holes peg board, multi shape peg board, hand tool test frame, finger dexterity board, door latch board, dressing board set, shoulder deduction ladder, bilateral shoulder ladder, hand exercise board Velcro, hand gym board, trolley with lock) 53 Vestibulator with facility of Platform swing, flexion disc, frog swing, Lycra swing , Bolster swing rectangular 54 Vestibular board - 3.6 X 2.6 X 7 – n(Vestibular Board should be of large size for rocking the body on board stimulates balance control with Vestibular Responses. nThe top should be of thickly upholstered and covered with rexine and washable fabric cover) 55 Scooter board – n(•tBoard with 4 Wheels (90cm Long x 30cm wide): It should help the child to learn body control, shifting weight, changing directions and maintain balance. Wooden Scooter Board with foam padded top should be used in a sitting, kneeling or prone position for developing strength of the upper and lower extremities.n•tIt should have ply-wood base, supported on 25mm x 25mm angular iron frame.n•tIt should have high density Foam padded top is 25mm thick & to be covered with nylon fabric in two Colours.n•tIt should be fitted with (4) four, 50mm dia castors.n•tBoard Size should be: 90cm long x 30cm wide) 56 Wedges of different sizes – n(•tWedges with set of four size: A: 15x60x70cm; B: 20x60x70cm; C: 25x60x70cm; D: 30x60x70cm) 57 Post box with 25 plates -n(•tSorting, Matching & Posting Box unit should measure an individual basic level of function in the area of colour identification and Eye-hand co-ordination.n•tConstruction of the box should be Laminated Wooden with five multicolour plastic plates fixed at the top with five Slots to Post matching colour plates there in.n•tIt should have 25 well-polished plastics plates in 5 different colors to sort, match and post.n•tBox should come with five compartments to be fitted with sliding door to store plates and also works as posting box.n•tIt should be Natural polished finish with laminated tops & door.) 58 Door latch board –n (The frame set provides learning opportunity and progressive development of dexterity. nWith six laminated doors, opening in different directions. nEach door opens into a shelf where a reward or toy can be kept. nCommon hardware of different designs, generally used in the home is used to familiarize Patient. Size of laminated unit is 26x18x5 deep.)nnn 59 Floor seater – n(•tFloor sitter should be useful for the child who cannot sit up on his own, and who needs his shoulders and upper trunk supported.n•tThese Floor Sitters must offer support in seating a child at floor level. This must allow the child to be independent, with hands free for play, while maintaining optimal erect trunk alignment.n•tConstruction: It should have Wooden Corner Seat, with broad base that help to prevent tipping.n•tSeat & Back should have Sitter with foam padded Seat, Sides and Back support.n•tAccessories should include abductor block, hip positioning belt & removable tray should be integral part of the floor sitter.nSeater should be finished in natural wood polish. Seat & Back to be covered with multi-colour Rexene) 60 Stand in table with Standing Metal Frame – n(Basic standing frame, with comfortably supports weight- bearing parts of the body. nIt Helps to prevent atrophy of leg muscles, improves range of motion, helps improve circulation, lessens muscle spasms and contractions n Three straps should be provided for heel, ankle and pelvic support) 61 Tunnel – n(•tCrawling tunnel Non-folding, Aluminum sheet with windows on sides and inner area padded with foam should be suitable hospitals with multiple patients.n•tTunnel Set of three parts with windows on sides are padded with soft Eva foam inside. n•tIt should be made in three parts of 90cm long each, all the three tunnels should be fixed together to make a single tunnel of 2.75 meter length.n•tInside Diameter should be 50cm dia.) 62 Treatment Plinth– 63 Wooden blocks of different heights- set of 6– 64 Peanut ball– n(•tIt can help you achieve muscle and tension release for all parts of the body.n•tPeanut shape design, convenient to use.n•tSuitable for yoga, Pilates, etc., help you has better fitness effect.n•tMade of durable PVC material for long term using.n•tFeatures: Peanut Shape, Inflatable, Explosion-proof, Durable, Fitness Tooln•tSize: 45cm x 95cm/17.72 x 37.40 (Approx.) 65 Staircase– n(•tStep arrangement: FOUR 15cm steps on one side, leading to platform size 75cm x 75cm. First step moves into the second to make it a bus step of 30cm height. 7.5cm steps on the other side. Steps are 75cm wide & 23cm deep (approx.).n•tFitted with 2 sets of handrails at different height to accommodate Adults & children. n•tSteps and Platform are made of commercial board of 12 mm thickness & covered with non-slip matting. n•tSides & Supporting frame of Steps are made of commercial board of 18mm thickness with hardwood reinforcement. n•tHand Rails & supporting bars are made of solid hardwood. Stairs finished natural) 66 Parallel bars with platform-n(•tParallel Bars should have adjustable Height & Width with PVC. n•tOuter uprights of thick steel tubing0 of 50mm dia. with Powder coating finish. n•tPlatform: Tubular steel reinforced platform with incline on both ends & is covered with non-slip matting. n•tLength: about 10feet n•tAdjustments: Should be easily done by means of setting Pins at the required holes & should be stabilized by tightening the screws. n•tFinish: Working Parts are with powder coated / chrome plated finish & wooden parts with Natural polish finish.n•tCovered with non-slip matting.n•tPostural Training Mirror: Mirror should be of size 175cm x 53cm (approx.) and should be protected by hardwood polished frame with back covered by ply board. n•tStand: Mirror should be fitted on tubular stand with powder coated finish) 67 Suspension framenSuspension Frame (with Accessories) without Bedn(•tSuspension Frame set for complete Suspension with Slings & Ropes. n•tTop Mesh should facilitate suspension at any desired point in relation to the patient and as required in each individual case. n•tConstruction: Tubular steel frame with 6mm thick Rod-mesh at Top and on Upper Sides. n•tLegs should be fitted With Rubber/PVC Shoes.n•tSizes: Overall sizes 210cm long x 110cm (approx.) wide at the base, 50cm (approx.) wide at the top & 190cm (approx.) high.) 68 Stability Disc–n(It should have balance Cushion - an Inflatable cushion that must come with 2 different surfaces that introduce an element of stability to a workout, must be ideal for both balance and core training. The balance cushion must allow users to exercise and working to stay balance; with constant micro movements that will strengthen the core muscles and improve postures. It should have the benefits of using Balance Cushion. Strengthen core muscles and improve postures required. Diameter- 33 cm required. Colors required: - Lime Green(Spiky Surface), Blueberry (Smooth Surface)) 69 Vibrator (with 6 attachments) – n(•tThe unit should be able to vibrate against the body and stimulate the nerves for a relaxing feeling.n•tIt should give horizontal circular motion which effectively relieves muscular fatigue and pain.n•tIt should have following two speeds:n•tHigh with rpm 3500n•tLow with rpm 1500n•tIt should have cooling system for continuous use so that massage can be done for long time.n•tIt should have durable body for professional use.n•tIt should be heavy duty and the weight should be above 2.5 kg.nIt should have two handles for applying pressure on the chest/muscle group.) 70 Ramp and curb– n(CURBS AND RAMP (without handrails) Hardwood constructed training set consists of ONE ramp and THREE nested curbs stored below the ramp. The ramp graduates from 20mm to 200mm and is 84 X 44. The curbs are 40x 40x 6, 36x 36x 4 and 32x 32x 2 respectively. Natural wood finish with anti-slip safety mats on ramp and curbs without handrails) 71 Balls for ball pool– n(It should have brightly colored balls encourage movement plus give child visual & tactile feed-back and support. * Size of ball should be of 7cm or 8cm dia with different colors) 72 Ankle exerciser-n(Painted aluminum boot with strap to hold the foot is mounted ona laminated base with Stainless steel sheet bracket having two springs for ankle (Dorsi and Plantar flexion) exercises. nResistance can be increased further by tightening springs nut. nDegree of flexion can be measured and recorded) 73 Walker with 4 castors - non folding-n(Walking Aid Folding & Adjustable HeightnLight weight, painted aluminum tubular construction, folds easily and quickly. Height of frame is adjustable from 75 c.m. to 90 c.m. by slipping locking pins in proper notch. Fitted with soft PVC hand grips and shoes) 74 Circle balance disc-n(•tThe board should have encourages Balance and Neuromuscular Re-education, Rhythm, Coordination and Vestibular responses. Children can use it in kneeling or standing position.n•tTop Diameter should be 51cm round, cushioned top covered with rexine.n•tBase must be fitted with semi-circular base, 60mm height.n Hand-Holds must be of Two, Side holds to be provided for stability) 75 Board for lower extremity - standing exercise 76 Foot placement ladder– n(•tIt should be useful in early walking with balance training. n•tShould be of wooden floor ladder with adjustable dividers, n•tShould offer various walking patterns. n•tSteps should be of equal size and alternately placed for right-left progression.n•tBeams & Dividers should be made of Teak-wood with size 96 long x 27 wide.n•tBeams should be finished in natural wood. n Adjustable 16 Divider bars should be finished in different enamel colours) 77 Graded spring set– n(•tSuspension Springs should be made out of best steel wire, with chrome plated finish; the rope is fitted in the spring to avoid overstretching.n•tTension of the springs must be: A. 5 kg-7kg., B.8kg-10kg., C. 12Kg-15kg. D. 18kg-20kg., E. 22kg-25kg.n•tSet should consist of ONE spring each (A+B+C+D+E) with S hooks.n•tIt should be Suitable for Extension, Flexion and Suspension activities.n It should be Full Set of 5 springs) 78 Long Handle thick grip spoons-n(•tIt should have stainless Steel long handled spoons, with smooth spoon tips.n•tThe spoons must help child/baby to master fine motor skills.n•tThese spoons must be easy to clean and maintain.n It should have set of 05 pieces) 79 Tactile balls for grip-n(•tIt should have Bumpy sensation when these are squeeze by hands. Knobby surfaces and bright colours should promote sensory and tactile exploration and it must help develop fine motor skillsn•tIt should have soft and squeezable material easy for small hands to grab and promote hand-eye coordinationn•tIt should have soft, knobby surface to provide massage stimulation for little ones. n•tIt should be supplied with Set which includes (06) toys in assorted colours and shapes (Round, Square, Cone, Pyramid & Rectangle etc.).n•tIt should be BPA, Latex and Phthalate freen•tIt should be helpful to build and define childs gross motor skillsn It must be Capture childrens interests and Hearts) 80 Lotca battery test-n(•tIt should have the plan to provide the appropriate therapy. n•tThe DLOTCA (Dynamic Lowenstein Occupational Therapy Cognitive Assessment) battery must design to offer this type of critical assessment. n•tThe DLOTCA battery must measure the cognitive abilities of those with neurological impairments or injuries.n•tIt should have a set of minimum 28 sub-tests analyses the cognitive areas pertaining to: Orientation, Awareness, Spatial Perception, Visual Perception, Vasomotor Construction, Praxis and Thinking Operations. n•tThe DLOCTA should be supplied with full kit with the following Components: Instruction manual authored by top leaders in the occupational therapy field Test booklets and score sheets Card and shape sets for various sub-tests.nPegs and peg-boards must have followings…n•tTen 1 x 1 natural wood blocks.n•tFour 1 x 1 blue wood blocks.n•tTwo 1 x 1 orange wood blocks.n•tThree 1 x 1 green wood blocks.n•tOne 1 x 1 yellow wood block.n•tButter-fly puzzle. Photo book.n•tSafety scissors.n•tPencil, paper and envelope.n•tCarrying bag.n•tThe kit is compact for easy transportation weighingn•t8.5 pounds and measuring 4.5 x 10.5 x 16.5 inches.) 81 Minnesota test-n(•tIt should measure manual dexterity of the Arm and Hand for manipulative work, utilizing a broad range of shoulder motion.n•tTest should involve Turning, Placing or moving the discs in a prescribed manner. Requires unilateral & bilateral movements.n•tTests should include 60 two colored plastic cylinders, plastic board, record forms and carrying case) 82 Exercise frame - rope mess, pip ladder and rock climbing board 83 Tilt Table– 84 Wobble Board– n(•tAnti-Slip Wooden Wobble Balance Board for Fitness & Training Rehabilitation Exercisen•tHigh Quality Material And Durable: Consisting of quality wood and tough plastic base, highn•tStrength, enduring for daily training.n•tStrength Stability: The balance board also enhancing the muscle strength of waist and n•tAbdomen, beautifying the hip muscle.n•tRotatable: The can support 360 degree horizontal rotating when placing it on flat ground.n•tKeep Balance: Stimulating posture conditioning, strengthening the stability of the vestibular.n•tOrgans and improving the bodys balance.n•tWidely Usage: The balance board is suitable to be used for hemiplegia stroke and other post-balance rehabilitation training.n•tWarranty not applicable for this product) 85 Cryo Therapy Unit–n(•tTherapeutic device should be capable to produce a real deep thermal shock effect.n•tThe thermal shock is a physiological stress should produce by sudden or rapid temperature variations in the local tissues.n•tThe system should not only allow performing cry therapy or hyperthermia separately but also and above all thermal shock therapy in a dynamic and controlled way.n•tHyperthermia, transdermal cryothermica and thermal shock can be modulated in depth and intensity.n•tShould be equipped with a treatment head based on the technology of Peltier cells capable of generating heat or subtracting heat in a range from +45°C to -18°C.n•tA special sensor should transmit the target temperature and the local body temperature should appears on the LCD screen in real-time to inform the operator how the therapy is acting on the patient.n•tAll the functions should be visualized on a large color LCD in addition to the usual and traditional keys and buttons,n•tShould be possible to adjust every parameter on the touch screen.n•tThe versatile Windows CE operating system should ensure possible upgrading.n•tShould have availability of a wide range of preset protocols with body maps. n•tThe screen should show the body parts to be treated and the unit should suggest the parameter values to set after selection of pathology is chosenn•tShould have free memories for entering customized protocols.n•tTemperature: from +45°C to -18°Cn•tShould have Colour touch screen displayn•tCompact unit with dimensions: 41 x 42 x 18 cm or smallern•tLight Weight: Not more than 9 kgn•tSafety class: class I type B, class IIa) 86 Electrical traction with 3 fold Bed-n(•tThe traction unit should consist of set of mechanisms for relieving pressure on the skeletal system.n•tIt should have a large LCD display panel showing all parameters.n•tIt should have at least 8 different modes (a) Intermittent (b) Static (c) Progressive/ intermittent (d) Progressive/ Static (e) Progressive/ Regressive (f) Cyclic /Intermittent (g) Cyclic / Static (h) Cyclic tn•tIt should consist of automatic calibration of traction force to maintain correct traction force.n•tIt should have high/low force range of 1-90 kg/0-89 kg.n•tIt should be possible to apply cervical as well as lumber traction with the machine.n•tIt should have adjustable hold and rest time range of 0 –99 sec.n•tIt should have selectable ramp steps of 2-8 steps with selectable pause time of 2-20 sec. for each step.n•tIt should have 5 different pulling speeds.n•tIt should have memories storage of at least 30 treatment patterns.n•tIt should have timer of 90 minutes.n•tIt should be supplied with Fixed Height Traction bed (Indigenous).n•tShould be supplied complete with Traction Unit, Cervical Harness ,Pelvic Harness, Spreader Bar, Patient Switch) 87 Treatment couch– n(HIGH-LOW TREATMENT TABLE (Electrical)nElectric, variable height, three section table is suitable for all treatments, including manipulation both ends elevate so that the back or legs can be raised without turning the patient. One ends also lower -20 deg. for some postural drainage & manipulation techniques and more comfortable sitting. The foam padded top is 195 cm long and 70 cm wide. Table height is adjustable from 50 cm to 90 cm. Frame-work in light blue oven baked finished) 88 Pain Relief System -n(•tCombination therapy unit with Heat, magnetic force and micro vibrations.n•tThe system should be modern with touch button operation.n•tThe system should consist of two channel unit with 2 hot packs for simultaneous use.n•tIt should have flexible heating pads emitting dry heat so that it can be used over clothes in normal conditions.n•tThe heating pads should have four steps temperature control from 35º to 60ºC.n•tMaximum temperature should not exceed 65 deg for patient protectionn•tIt should provide vibrations through flexible heating pads which help in the stimulation of blood flow on painful areas.n•tThe system should have three different types of micro vibrations as below :notRipple wave: - 70 vibrations per secondnotRandom wave: - 120 vibrations per secondnotBig wave: - 60 vibrations per secondn•tIt should also provide Magnetic force for improving the blood flow.n•tMicro vibration should be from alternating magnetic fieldn•tIt should have digital timer of 30 minutes duration.n•tIt should be supplied with an imported trolley and should work on 240 V/50 Hz power supply.n•tIt should UL, and ISO 13485 approved for patient safety) 89 Wheel Chair for Children– n(The system should have following parameters:n1.tPediatric Wheelchair, Aluminum Chair frame, fixed armrest, Detachable footrest, Drop-back handle, solid castor, pneumatic rear wheel, Anti-tippers.n2.tLoading weight should be minimum 100 kg) 90 Club foot Passive exerciser & Therapy System – n(•tThe CPM should be for treatment of the idiopathic club foot which should restores or maintains ankle and subtalar mobility in addition to preventing fibrosis and periarticular soft tissue changes.n•tThe CPM should be used in the post-operative phase of treatment.n•tThree dimensional movements should be possible:n•tPlantar flexion to Dorsi-flexionn•tAdduction-Varus to Abduction-Valgusn•tPlantar flexion-Adduction-Varus to Dorsi-flexion-Abduction-Valgusn•tDigital controls should allow easy programming.n•tAt rest or working the machine should maintain a light axial traction which off-loads the pressures which are applied to the ankle mortise to avoid any deformation of the tibio-talar joint line.n•tThe machine should be equipped with a system which reverses the movement when abnormal forces are detected.n•tIt should be European CE approved) 91 Children Medical Cycle-n(•tUpright Ergometer for physical abilities such as workload etc. n•tIt should be able to work continuous work load range from 7-1000 watt.n•tIt should work for minimum five minutes at a peak load of 1000 watt for short period.n•tThe work load should be adjustable @ 1 watt increment.n•tIt should have 7 inch touch screen programmable LCD display to show various parameters such as distance, torque, power, energy and time on its control panel.n•tIt should provide workload in hyperbolic, linear and fixed torque modes.n•tIt must have eddy current electro-magnetic braking system.n•tIt should have USB interface.n•tWorkload accuracy should be = 5%.n•tIt should display distance, torque and time on its control panel.n•tIt should have Rotatable height adjustable handlebar redundant, rotate at 360 degrees for comfortable at every seating height. n•tIts seat should be sleeplessly adjustable.n•tIt should comply with MDD 93/42/EEC, incl. IEC.) 92 Ultrasound- 1 and 3 MHz Frequency – n(Digital Dual Pre Programmable Ultrasound therapy unit with constant digital LCD display adjustable treatment should be supplied having following parameters: n?tNominal Frequency: 1MHz & 3MHzn?tPower Density : 0-3W/cm2 (Approx.)n?tMix Acoustic output: 15W (Approx.)n?tUltrasonic Output : Continuous- 2.5 W/cm, Pulse- 3.5 W/cmn?tPulse Frequency: 8hz, 16hz, 50hz, 10hzn?tPulsed Ratios: 1:1,1:4,1:7,1:10n?tTimer: 0-99 minutesn?tVoltage:220 V,50Hz±10%nAccessories to be supplied:n•t1 pair - Ultrasound Head (1Mhz) & Wiren•t1 pair - Ultrasound Head (3Mhz) & Wire n•t1 pc - Main Cord) 93 Computerized Interactive Dynamometer System:-n(Computerized interactive dynamometer system should have following specifications;n•tThe system should comprise of user-friendly and easy-to-control rehabilitation robot to allow rehabilitation Training with dynamically changing resistance, diagnostics, patient evaluation and interactive games.n•tThe system should be upgradable to make use of reactive electromyography (EMG) for neuro exercise. n•tSingle joints or functional and dynamic joint movement should be trained with isolating extensions. n•tThe robotic system should be suitable to provide Kinesitherapy for orthopedic, neurological and cardiac patients of Adult and Pediatric age groups. n•tShould have dedicated exercise program for patients with severe paresis and muscle atrophy. n•tSystem should offer active exercises on all extension for Patients with innerved muscles but severe atrophy n•tThe device should offer exercises for dexterity training with dynamically changing resistance: concentric with elastic resistance and weight simulation.nn•tShould have inbuilt games and dynamic resistance exercises and to improve movement coordination. n•tShould have the facility to upgrade with games working with reactive electromyography n•tShould have tablet mounted on a retractable arm with height adjustable lifting column and preloaded Software application for quick setup and operationn•tShould be mounted on wheels with brakes for easy transportation and immobilization of the robot n•tEach extension should support a maximal applied weight of at least 30 kg. n•tThe rotation axis height of head should be at least 720-1070 mm and rotation limits should be at least 270 degree clockwise and anticlockwise with accuracy at least ±2 deg and Maximum torque: at least 60 Nm with measurement accuracy at least ±0.2 Nm.n•tShould be supplied with changeable extension parts for training and exercise of different joints including Shoulder, Elbow, Hip, Knee, Functional upper limbn•tShould include following extensions easy to mount in any orientation by plug and rotate method and automatic detection by the software: n•tElbow pronation/supination dynamic extension - n•tSteering wheel dynamic extension - n•tUpper limb universal extensionn•t Lower limb universal extension n•tThe system have facility for bioelectric measurements for diagnostic and reactive electromyography with clip electrode for EMG Measurement n•tSystem should have adjustable Range of motion, rotational torque and speed to suit different patient conditions. n•tThe software should provide summary and detailed extension specific information about all performed exercises after every training. n•tSystem Should allow following exercises and diagnosis :na.tContinuous passive motion nb.tProgressive Continuous Passive Motionnc.tSpring (Elastic) exercises:nd.tIsotonic exercises (weight lifting)ne.tDynamic reversalnf.tPrioperception – Hidden/Visibleng.tReactive electromyography trigger and hold nh.tReactive electromyography trigger and release ni.tEMG Biofeedback nj.tDiagnostic EMG nk.tThe software should have three primary game categoriesni.tOrthopedic – acting like concentric exercisesnii.tReactive EMG – acting like reactive electromyography trigger and holdniii.tIsometric EMG – acting like EMG biofeedbacknl.tAt least two games should be provided: Space shooter and Bubble.ni.tSpace shooter a game where the patients control the movement of a spaceship. nii.tBubble- a logic game where patients control the position of a bubble gun launching different color bubbles to form patterns. nThe system should meet the requirements of ISO60601-1-2 for electromagnetic compatibility, including immunity. Should have Class I protection against electric current, Medical device class: class IIa Applied part types: B, BF. ) 94 Lymphatic drainage system 95 BONE GROWTH STIMULATOR 96 Two Channel Combination Therapy With Dual Frequency Ultrasound-n(The Main unit should have:-n•t2 channels electrotherapy unit with 4 electrodes & 1 channel dual frequency ultrasound (1 or 3MHz).n•tColoured touch-screen large LCD for all parameters setting.n•tSimultaneous monitoring of 2 electrotherapy & one ultrasound channel with independent and combined n•tThe unit should operate on100 - 240 VAC 50 Hz.n•tWeight of equipment should be approximately 3.5 Kg for ease of moving.n•tIt should have body diagram with associated clinical programsn•tIt should also have port for attaching vacuum unit. n•tSafety class according to IEC 60601-1: Class 1, Type BFn•tUnit should be European CE approved.nElectrotherapy specifications:n•tDigital Timer: 1-60 minutesn•tIt should also have provision of I/T curve measurement n•tIt should also have setting range for AQ mode whenever vacuum unit is attached.n•tIt should have approximately 28 preset and 120 free program memories n•tVector Sweep 0°, 15°, 30° or 45°nIt should have following setting range:n-tParameter setting range for 2-Pole Interferential moden•tOutput mode: Constant, Sweepn-tParameter setting range for EMS moden•tOutput mode: Surge Independent, Surge Co-Cont., Surge Alternaten-tParameter setting range for Russian moden•tOutput mode: Surge Independent, Surge Co-Cont., Surge Alternaten•tCarrier frequency: 2.5 kHz n•tDuty: 10 to 100% (10% steps)n-tParameter setting range for Hi-Voltage moden•tOutput mode: Constant, Sweep, Burst, Surge Independent, Surge Co-Cont.,n•tSurge Alternaten•tPolarity: positive, negative, alternaten-tParameter setting range for TENS moden•tOutput mode: Constant, Sweep, Burst, Surge Independent, Surge Co-Cont., Surge Alternaten•tWaveform setting: Symmetrical waveform, asymmetrical waveformn•tPolarity: positive, negative, alternaten-tParameter setting range for Micro current moden•tPolarity: positive, negative, alternaten-tParameter setting range for Galvanic moden•tOutput mode: Continuous, Interruptedn•tPolarity: positive, negativen-tParameter setting range for Faradic moden•tPolarity: Positive, negativen•tFrequency: 20 to 250 Hz (10-Hz steps)n-tParameter setting range for Diadynamic moden•tOutput mode: DF, MF, CP, CP-ISO, LP, RSn•tPolarity: positive, negativen•tFrequency: 50 Hz or 100 HznUltrasound specifications:n•tBeam Non-uniformity Ratio (BNR) which prevents hot spots & tissue damage should be less than 5.0 and must be mentioned on the technical literature.n•tEffective Radiating Area (ERA) for large probe should be max. 5 cm2 & for small probe should be max. 1.0 cm2n•tFrequency: 1 & 3 MHz from same headn•tMode: Continuous & pulsed; duty cycle 5-50%n•tMax. Intensity: 3w/cm2in pulsed mode & 2 w/cm2 in continuous mode.n•tDigital Timer: 1-30 minutesn•tMemory capacity of: 18 preset & 10 free Programsn•tUS Probe should be IPX7 protected.nCombination Therapy:n•tIt should work in combination of Ultra sound and electrotherapy with dedicated single electrode of channel 2 as return electrode for electrotherapy and active as US probe.nIt should be supplied with following accessories:nUltrasound head large and small with probe holder, Electrode Cable – 2 pcs., Rubber Electrode, 60x50mm, 2pcs/pack – 2 Pack , Electrode Sponge A, 80x65mm, 2pcs/pack – 2 Pack, Strap (L), 80x1200mm – 2 pcs., Strap (S), 80x600mm – 2 pcs, Ultrasound gel (250 ml), Power Supply Cord (220-240V, Type F) – 1 pc., MCR (Micro current) Probe (2pcs/set to be used), HV/DC ProbenVacuum Unitn•tVacuum unit for enhancing the operability of electrotherapy units especially in abdominal & back regions. n•tThe unit should consist of 2 channel vacuum system for 4 vacuum electrodes.n•tIt should have blow out vacuum system which eliminates the need of water reservoir & reducing maintenance.n•tThe unit should have 2 vacuum modes: Continuous mode & int ermittent mode for patient comfort & skin massage.n•tThe unit should have vacuum strength up to 100 mm Hgn•tThe unit should operate on 100 - 240 VAC with 50 Hz frequency power supplyn•tMain unit should be supplied with:- 4 rubber electrode, 4 electrode sponge, 2 electrode cable, 4 straps (2 large and 2 small), 4 Vacuum electrode, 4 Electrode sponges for Vacuum electrode, Power supply cord.) 97 AUDIOLOGY & SPEECH THERAPY UNIT 98 Single Portable Unit -Pure tone Audiometer with facilities of free field audiometry & speech audiometry with-nFrequency range for AC- 125Hz to 8000HznFrequency range for BC- 250Hz to 6000HznDynamic range (1000Hz)- -10dB HL to 120 dB HLnShould be European CE/ANSI/ISI approved 99 Non-sedated diagnostic BERA with 2 channel and VEMP, ABR & SSR facilities and computer accessibility through USB portal 100 Video Oto-scope with computer accessibility 101 Acoustic booth 15’x12’x 7’ with inner partition, double door, magnetic seal, silenced ventilation 102 Visi-pitch with all accessories 103 Bio feedback system for stammering therapy with all accessories 104 Speech therapy materials (Local purchase) 105 Mattress 6’ x 6’ 106 Group Hearing aid with loop induction system 107 Mattress 6’ x 6’ 108 PSYCHOLOGY UNIT 109 Binet Kamat Intelligence Test (BKT) 110 Intelligence Scale for Indian Children 111 Bhatia Battery of Performance Intelligence Test 112 Diagnostic Test of Learning Disability (DTLD) 113 Diagnostic Test of Reading Disorder (DTRD) 114 Behavioural Checklist for Screening the Learning Disabled (BCSLD) 115 Swarup-Mehta Test of Thinking Strategies (TTS) 116 Thematic Apperception Test (TAT) 117 Non-Verbal Group Intelligence Test (NVGIT) 118 Rorschach Ink Blot Test 119 (DAP:IQ)Draw-A-person Intellectual Ability Test for Children Adolescents and Adults 120 Conduct Disorder Scale (CDS) 121 Revised Hamilton Rating Scale for Depression (RHRSD) 122 Indian Adaptation of the Multidimensional 123 Aptitude Battery - MAB – II 124 Child Sexual Behaviour Inventory (CSBI) 125 Teachers Job Satisfaction Scale 126 ADHD Symptoms Rating Scale (ADHD-SRS) 127 CHILD & ADOLESCENT SYMPTOM INVENTORY-4R (CASI-4R) 128 Multiscore Depression Inventory for Children (MDI-C) 129 Stop Watch [Timer] Racer Electronics [SWE] 130 Gifted and Talented Evaluation Scales 131 Test of Memory and Learning - Second Ed. (TOMAL-2) 132 Early Childhood Inventory-4 (ECI-4) 133 Slosson Full-Range Intelligence Test (S-FRIT) 134 Bender Visual-Motor Gestalt Test - Second Edition (BGT - II) 135 Stroop Color and Word Test (Children) 136 Personality Inventory For Children 2nd Ed. 137 Seguin Form Board Test with Manual & Answer Sheets. 138 Childhood Autism Rating Scale - Second Edition (CARS 2) 139 Children’s Color Trails Test (CCTT) 140 Intelligence Test for Adult 141 State-Trait Anger Expression Inventory-2™(STAXI-2) 142 Multi-dimensional Anxiety Questionnaire (MAQ) 143 Substance Abuse Subtle Screening Inventory (SASSI-3) 144 Suicidal Ideation Questionnaire (SIQ) 145 Relaxation Chair 146 ISAA & INCLEAN TOOLS for ASD 147 BLOOD DISORDER DISABILITY UNIT 148 Thalassemia Rapid test 149 Blood Gas Analyzer 150 Methylene Blue Chemical – 151 Urine Analyzer– 152 VISUAL UNIT 153 Hand held slit lamp 154 Direct Ophthalmoscope 2.8 v 155 Trial set power cotted/Stereo Acuity Test material 156 Trial frame for both adult and paediatric 157 Distance vision testing drum remote control motorised movement 158 VS-V Universal Vision Screener (for school going children also) 159 Tele Binocular Equipment 160 LED Vision Chart 161 Snellen Chart/Eye Testing Drum 162 Automatic Matrix Auto Refractometer R-20 for eye Examination 163 Near Vision Drum 164 Acuity Digital Vision Tester 165 Keratometer&Keratoscope tools 166 Brallier (Braille Type Writer) 167 Orbit Reader (Braille Embossed Reader) 168 Pen Scanner 169 Magnifiers for low vision (NIEPVD) 170 MAGIC software for low vision 171 Electronic Mobility Cane/White Cane 172 TEACHING LEARNING MATERIAL-n(N.B.-All TLM should be made of Nontoxic, Hygienic material ensuring safety of children. Toys should not have any sharp edges to prevent any possible injury to children.) 173 Rattle toys-(Age Group 0 to 3 Years) 174 Fruit Tray-(Age Group 0 to 3 Years) 175 Parts of body-(Age Group 0 to 3 Years) 176 Building Towers-(Age Group 0 to 3 Years) 177 Different Balls-(Age Group 0 to 3 Years) 178 Zig saw Puzzle-(Age Group 0 to 3 Years) 179 Dolls-(Age Group 0 to 3 Years) 180 Wooden Blocks-(Age Group 0 to 3 Years) 181 Drum-(Age Group 0 to 3 Years) 182 English Alphabets & Numbers- (Age Group 3 To 6 Yrs.) 183 Flash Card of Alphabets & Numbers- (Age Group 3 To 6 Yrs.) 184 Eye hand coordination (Beads)- (Age Group 3 To 6 Yrs.) 185 Abacus– (Age Group 3 To 6 Yrs.) 186 Shape, Size, Colour, Concept &. puzzle box – (Age Group 3 To 6 Yrs.) 187 Zig saw Puzzle– (Age Group 3 To 6 Yrs.) 188 Colour book with crayon holder– (Age Group 3 To 6 Yrs.) 189 Easel and Board– (Age Group 3 To 6 Yrs.) 190 Magic Slate– (Age Group 3 To 6 Yrs.) 191 Blowing toys– (Age Group 3 To 6 Yrs.) 192 Picture and Ward Cards - (Age Group 7 To 11 Yrs.) 193 Assembly Kit- (Age Group 7 To 11 Yrs.) 194 Number Cards- (Age Group 7 To 11 Yrs.) 195 Zig Shaw Puzzle - (Age Group 7 To 11 Yrs.) 196 Telling Time Kit - (Age Group 7 To 11 Yrs.) 197 Count and Match - (Age Group 7 To 11 Yrs.) 198 Puzzle body parts - (Age Group 7 To 11 Yrs.) 199 Coloring Books with Crayons– (Age Group 7 To 11 Yrs.) 200 Beads– (Age Group 7 To 11 Yrs.) 201 Magic Slate– (Age Group 7 To 11 Yrs.) 202 Duplicate Currency– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 203 General Knowledge Flash Cards– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 204 Mobile Phone– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 205 Calculator– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 206 Digital Watch– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 207 Number Cubes– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 208 Multiplication Tactile Board– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 209 Worksheet, Pen & Duster, Story Books– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 210 Coloring Books with Crayons– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 211 Kitchen Set– (Age Group 12 To 15 Yrs. & 16 To 18 Yrs.) 212 SPORTS MATERIALS 213 Recreational Gaming Play Station 214 Eye Convalescence System –with Bed 215 EMG Biofeedback With Pelvic Floor Rehabilitation For Urinary Incontinence
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
15.
Defence #10569480 Price Bid
Tender For Defect Rectificationon Various Equipment Onboard Icgs Samudra Prahari At Goa- Defect Rectificationon Various Hull Equipment Onboard Icgs Samudra Prahari At Goa 2 H-1083:20 No’S Ship Side Scupper Lips With Movable Type Brackets And Rubber Lips And 12 In Nos. Goose Neck Flaps Corroded / Thinned Down To Be Renewed As Per Sample Alongwith Rubber Padding Of 12 In Nos. Goose Neck Flaps And Ship Side Scupper Lips. Mat Of Goose Neck Flaps- Ms Size- 270 Mm Dia X 04 Mm ) Circular Plate With Rubber Padding. Rubber Padding Of 12 In Nos. Goose Neck Flaps - Neoprene Rubber Of Dia 270 Mm X 03 Mm Thick. Flap Securing Butter Fly Nut / Bolt Of Flaps Broken 08 Butter Fly Nuts / Bolts To Be Renewed. Size Of Scupper- 200Mmx 200Mmx40 Mm , Rubber Lip Size- 200Mmx 200Mmx40 Mm X 6 Mm Thick, Rubber Grade- Nitrile Rubber All In Way Job Involves Removal Of Insulation And Lagging And Panelling From Internal Compartments. 3 H-1087:Air Ventilation Supply / Exhaust Wire Mesh And Side Frame At General Compartments And Mer, Dg Room Perished / Deteriorated. Wire Mesh With Side Frames To Be Renewed. Size Of The General Compartments-500X 300 Mm To Varying Size, 12.5 Mm Mesh, No- 25.Size And Material Of The Mer And Dg Room Mat- Ms Frame, Wire Mesh Size – 10 Mm, Total No-06 Nos, Size As Follow:-Sl No Grill Size Compartment ( I ) 1100X900-02 No, Msframe -05 Mm. Dg Room ( Ii ) 600X 250 -02 No, Msthick -05 Mm. Dg Room ( Iii ) 600X 600-01 No, Msthick -05 Mm Dg Room ( Iv ) 600X1300-02 No Msframe -05 Mm. Mer ( V ) 700X 800-02 No Msframe -05 Mm. Mer ( Vi ) 800X1300-01 No Msframe -05 Mm. Mer ( Vii ) 600X 1300-01 No Ms Frame -05 Mm. Mer ( Viii ) 300 Mm Dia , 12.5 Mm Wire Mesh , Circular Pc Hold ( F ) & Aft, -06 No 4 H-1088: 06 No Galley Grease Filters ( Multiple Layer Wire Mesh ) Perished And Frames Deteriorated. To Be Renewed As Per Sample. Size-400X 300 -04 Nos, 300X 300-02 No. 5 H-1095:03 No’S Air Treatment Unit Casing Doors And 10 No’S Inspection Door Openings With Side Frames On Deck Head Related To Ventilation Trunks Corroded / Perished To Be Renewed As Per The Sample. Mat And Size Of The Inspection Door- Ms, Size- 250 Mm X 250Mm X2 Mm, Mat And Size Of Atu Door –Gi, Size-1000Mmx625mm. 6 H-1194: Jr Sailor, And Officer’S Scullery Wash Basin Tray Mess Deteriorated And Sr Sailor Water Cooler Tap And Tray To Be Renewed. Scope Of Work Includes Renewal Of Basin Tray As Per The Sample.Qty- Tray Mesh - 04 No’S, Tap -01. 7 H-1195:02 In No’S Mirror Faded In Ship’S Galley And Barber Shop. Bar Shop Hydraulic Chair Cylinder Oil Leakage Observed. Mirrors To Be Renewal As Per The Sample And Chair Cylinder To Be Repaired And Proved. 8 H-1196:02 No’S Rope Reel Plumber Block Bearings Base And Bearings Corroded / Deteriorated. To Be Renewed As Per The Sample. 9 H-1198:04 Nos Three Seat Sofa Rexene Of Sr. Sailor Dining Hall And Domestic Mess, Barber Shop Damaged. To Be Renewed As Per Sample. Job Included: - ( I ) . Renewed Foam 30” X 30” X 4”. ( Ii ) . Renewed Rexene 1 Mtr X 1 Mtr. 10 H-1200:Gun Deck, Boat Deck, Helo Deck And Gemini Deck Railing Corroded / Deteriorated To Be Repaired / Renewed As Per Sample. Mtr-30 Mtr. 11 H-1202:Jr. Sailor Scullery And Engineering Officer Cabin Wash Room Entrance Metallic Sheet Corroded / Deteriorated To Be Repair / Replaced As Per The Sample. 12 H-1203:08 No Securing Belt For Pc Boat Damaged / Perished. To Be Renewed. Length -10 M Each, Thick-8Mm, Width -50Mm, 04 No Securing Lock & Hook Link Also To Be Provided. 13 H-1204:15 No’S Dressing Line Pulleys And Securing Brackets And 03 No’S Halyard Secure Points Deteriorated / Corroded To Be Renewed As Per The Sample.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 12
18.
Defence #9992154 AOC
Bids Are Invited For Pol Account Voucher Register , Vehicle First Parade Register , Pol Transfer Register , Pol Demand Register , Pol Packing Note Register , Pol Monthly Or Surprise Muster Register , Fire Fighting Incident Log Book , Wet And Dry Fire Exercise Record Log Book , Fire Exercise Record Log Book , Fire Fighting Equipment Information Log Book , Record Of Static Tank Log Book , Fire Fighting Training Record Log Book , Occurrence Log Book , Local Flying Log Book , Ats Briefing Log Book , Crash And Fire Exercise Log Book , For Parade Log Book , Low Flying Log Book , Ranad Log Book , Pawan Hans Log Book , Air Field Surface Defect Log Book , Defect Book , Demand And Survey Register , Antenna Insulation Book , Dg Running Log Book , Daily Parade State Register , Daily Civil Labour In And Out Register , Weapon In And Out Register , Magazine Temperature Register , Night Time Civil Labour In And Out Register , Armoury Key In And Out Register , Magazine Key In And Out Register Dsc , Daily Arms In And Out Register , Daily Amn In And Out Register , Daily Gd Duty Register , Gunnery Log And Progress Book , Magazine Key Register , Expense Book , Expenditure Of Small Arms Ammunition , Competancy Certificate , Incoming Register , Outgoing Register , Tool Issue Register , Pol Register , Lfc Issue Book , Requestment Book , Nc 16 In And Out Register , Motorola Issue Register , Dcn In Mail Register , Dcn Out Mail Register , Landing Report Register , Metar Register , Climetology Register , Exos Request And Alteration Book , Gangway Wine And C Book , Liquor Card Register , Gate Pass Issue Register , Defence Civilian I Card Issue Register , Loss Of Pmt And Ty I Card Register , Pmt I Card Cancellation Register , Ty I Card Cancellation Register , Ty I Card Renewal Register , Daily Record Of Punishment Register , Cash Account Book , Cash Account Book For Owf , Cash Account Book For Wine , Cash Account Book For Mess , Wine Day Book , Wine Stock Book , Wine Bill Book With Duplicate Copy , Mess Receipt With Duplicate Copy , Wine Receipt With Duplicate Copy , Mess Bill With Duplicate Copy , Register Cover Navy Blue With Unit Logo Portrait , Register Cover Navy Blue With Unit Logo Landscape , Register Cover Navy Blue With Unit Logo A3 Size , Aip Register , Sanction Register , Budget Register , Crv And Cb Register , Iafs 1520 - Iafs 1521 , Acr Formleading , Acr Formpo And Equivalent , Acr Formcpo Andabove Equivalent , Snap Form , Scribling Pad With Unit Logo , Pts Register , Food Tasting Register , Stocktaking Rigister , Invitation Card With Cover , S Drive Issue Register , Training Register , Pc Landed In Eme Workshop Log Book , External Hdd Or Digital Storage Media Register , Computer Defect Book , Hd Destruction Register , Priscription Pad Total Quantity : 2611
Contract Date: Ref. Documents Contract Value : 2.49 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Andaman And Nicobar Islands View Result →
20.
Defence #9835139 AOC
Tender For Completion Of Incomplete Work For Provn Of Otm Accommodation (Ph-I Of Two Phs) At Panagarh Mil Stn Under Ge (P) Panagarh.; 1 Sch A Part -I (Building Works)Note:- This Sch is notpre-priced by MES and the pre-priced rate indicatedas Rs 0.00 under Col 5 signifies this fact only. 2 Completion of incomplete Building for signal unit with all fitting and fixtures etc. Complete all as specified and as shown on complete drawings. 3 Completion of incompleteBuilding for office accn/ Adm block with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 4 Completion of incomplete Building for JCO Mess and single living JCO accn with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 5 Completion of incomplete Buildingfor single living ORs accn / Dinning and cook house with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 6 Completion of incomplete Building for Storage Accn (Armouries)& Guard House alongwith hardstanding with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 7 Completion of incomplete Building for Store Room (General Authorisation) with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 8 Completion of incomplete ramp with all fitting and fixtures etc. Complete all as specified and as shown on drawings 9 Completion of incomplete Building for sentry post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 10 Completion of incomplete Building for Ironing Room with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 11 Completion of incomplete Building for Meter & Switch House with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 12 Completion of incomplete Pump House/ UG water tank with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 13 Completion of incomplete RCC OHT Tankwith 18mtr staging with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 14 Completion of incomplete Incinerator with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 15 Completion of incompleteFlag mast with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 16 Completion of incomplete Alarm post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 17 Completion of incompleteFire point with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 18 Completion of incomplete Refuse bin with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 19 Completion of incompleteDhobi ghat with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 20 Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATIONas listed in Schedule ‘A’ Part-II on Serial Page No. __ 21 Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III on Serial Page No. __ 22 Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. __ 23 Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V on Serial Page No. __ 24 Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI on Serial Page No. __ 25 Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII on Serial Page No. ___ 26 Lumpsum price worked out by the tenderer/ bidder for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VIII on Serial Page No. ___ 27 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX on Serial Page No. ___ 28 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLYas listed in Schedule ‘A’ Part-X on Serial Page No. ___ 29 Lumpsum price worked out by the tenderer/ bidder for LIGHTENING PROTECTIONas listed in Schedule ‘A’ Part-XI on Serial Page No. ___ 30 Lumpsum price worked out by the tenderer/ bidder for RAIN WATER HARVESTING / RECHARGE PIT as listed in Schedule ‘A’ Part-XII on Serial Page No. ___ 31 Schedule ‘A’ Part-XIII (MISCELLANEOUS ITEMS)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 signifies this fact only. 32 M & L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e10 %Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed .Note:Break down details of this Items is shown in Annexure ‘B’ in Schedule ‘A’ Notes. 33 (INTERNALELECTRIFICATION)Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box screws complete including PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point / call bell point controlled by one, one way switch complete all as specified and as directed. 34 All as per Ser Item No 13.02 here-in-above but for one ceiling/ exhaust fan point controlled by one switch complete all as specified and directed. 35 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one 5/6 Amps socket outlet points controlled by one, one way switch on independent board complete all as specified and as directed. 36 All as per item No. 13.04 above but one 5/6amps socket outlet point on the same board with other switches complete all as specified and as directed. 37 All as per item No. 13.02 above but for one Point wiring controlled by two nos two switch complete all as specified and as directed. 38 Material and labour for point wiring with 4sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 4 sqmm green colour as earth continuty conductor connected to common earth dolly for one15/16 Amps socket outlet points controlled by one, one way switch modular type on independent board complete all as specified and as directed. 39 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed stove enameled steel conduit of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point controlled by one, one way flame proof rotary type switch complete all as specified and as directed. 40 Supply and fixing switch flame proof rotary type with terminal box in LM6, 16 amps single pole 230 volts complete all as specified and as directed. 41 M & L for modular metal flush box 12 Module complete all as specified and directed. 42 M & L for modular white cover plate with frame, 12 module complete all as specifed and directed. 43 S & F for LED lamp 7 watt (retrofit) complete all as specifed and directed. 44 S & F LED type conical shape wall metal body with 1 no 7 Watt retrofit LED Lamp minimum lumen 700, complete all as specifed and directed. 45 S & F LED type table lamp / bed side light ( 3000k) Metal body 2 Watt minimum 50 lumen complete all as specifed and directed. 46 S & F telephone Socket (RJ-11) modular type complete all as specifed and directed. 47 S & F TV Socket modular type complete all as specifed and directed. 48 Supplying and fixing ceiling fan five star rated withBrush Less direct current (BLDC) 1200 mm sweep (without remote ) , 28 W complete withblades,down rod and accessories,230v,Min delivery 210 CFM with service value 6.00 BEE complete all as specified and as directed. 49 All as per Ser Item No 13.17 here-in-above but for 1400mm sweep, Minium air delivery 245 CFM with service value 6.00 BEE, five star rating with brushless direct current motor (BLDC) complete all as specified and directed. 50 Supplying and fixing exhaust fan made of sturdy Engineering plastic complete with lovers shutters, AC single phase, 230 V, 50 HZ , 1200 RPM, Copper winding, 250mm Sweep complete all as specified and directed. 51 Supplying and fixing exhaust fan noiseless square type metal body case , 450mm sweep heavy duty single phase (1400 RPM) ISI marked with blades flush mounting withlouvers, AC single phase 230/240 volts, 50 Hz including necessary fixing accessories and make good of surfaces complete all as specified and as directed. 52 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 6 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 53 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 8 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 54 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 4 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 55 Supplying and fixing MCCB 125 Amps, capacity 25kA, 4 pole, 415 volts (Adjustable thermal type & fixed magnetic setting) complete all as specified and as directed. 56 Supplying and fixing sheet metal enclouser for DBS Single pole and neutral 6 way double door with 200 Amps rated bus bar 240 Volt complete all as specified and as directed. 57 Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm diawith all fittings and conduit accessories concealed type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note:-(i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 58 Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm dia with all fittings and conduit accessories concealed type including one runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 59 Material and labour for sub main wiring with four runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less tha 25 mm dia with all fittings and conduit accessories concealed type including two runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) Four runs of cable with two runs earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 60 Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including complete all as specified and directed. {NOTE:- (i) Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item..} 61 (ROAD/PATH)M & L 225 mm thick (compacted thickness)wet mix macadam( WMM), with curshed stone aggregate and stone dust (as per design mix)of specifiedgrading, spread using mechanical paver as specified, watered, rolled & consolidated as specified to required gradient and camber complate all as specified & directed. 62 M&L for laying polythene paper black 150 micron with laps complate all as specified & directed. (Area for polythene paper without considering lap shall be measured and paid) 63 M&L and laying 150 mm thick (compacted thickness) wet mix macadam (WMM) with crushed stone aggragate of specified grading,spread using mechanical paver as specified, watered, rolled and consolidated as per required greadeant and camber complate all as specified & directed. 64 M&L for 100 m thick dry lean concrete (DLC) over a prepared subgrade with coarse and fine aggregate conforming to IS : 383, Size of aggregate not exc 40 mm (Grading and other parameters as per table 600 - 1 of MORTH, IRC SPR : 49 Specification) complate all as specified & directed. 65 M&L for cleaning and preparing the road surface and making good for road marking applying reflective thermoplastic white road marking paint (HOT APPLICATION) comforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass, beads, titanium dioxide, calcium carbonate, interfiller thermoplastic required for glass beads per square meter by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and as directed.Make of Thermoplastic Road marking paint/Retro-Reflective paint - M/s Asian Apcomark, M/s STP or M/s Shalimar Paints Ltd or M/s Berger Paints Ltd, M/s Jhonson & Nicholson Paints Ltd or M/s Jotun India Pvt Ltd. 66 (SEWAGE DISPOSAL)M&Lfor constrution of RCC Septic tankcoventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users Complete all as shown on drawing and as directed. 67 M&L for constrution Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.5 M effective depth Complete all as shown on drawing and as directed. 68 (EXTERNAL WATER SUPPLY) Design, supply, install, testing and commissioning Iron removal pressure feed type filtration plant 10000 GPH to with stand pressure 10 Kg/Sq cm with catalytic and filter media (as required size and grade / mesh to obtain potable water recommended parameters as per WHO) including MS frontal pipe (duly welded), Cocks, valves, (inlet outlet, back wash, rinse, bypass complete as per manufacturers instruction). Provision of main hole Hand hole strainer including air vent system, coagulant feeder with accessories, oxidation chamber with media, (MnO2) with all accessories suitable capacity with all fitting fixture, pressure gauges, RCC/PCC foundation as per OEM recommendation. Drainage system and connected to rising and delivery system including painting and writing complete. The technical details of Oxidation chamber and Multigrade filter are as given below:- 69 A) Oxidation Chamber- (i)Feed Flow - 40 M³/Hr. (ii) Operating pressure - 3.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm. (iv) MOC of vessel - MS. (v) Frontal Pipeline Size - 150/100mm. (vi) Media type - Manganese-di-oxide. (vii) Thickness in mm (shell and dish-ends) - 6 mm. (viii)Media Quantity - 600 Kg. (B) Multigrade Filter- (i) Flow rate - 40 M³/Hr. (ii) Operating pressure - 3.5-5.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm². (iv) Continuous duty cycle - 48 Hrs. (v) Backwash - 20 Min. (vi) Rinsing - 10 Min. (C) Filtering Media Details- (i) Media Type - Mixed sand. (ii)Depth of sand - 2800 Kg. (iii) Depth of Gravels support - 2000 Kg. (iv) Guaranteed life of filtering media - One year.(D) Vessels Details- (i) Type Cylindrical - Vertical. (ii)Dimension in mm (DIA X HOS) - 1600 X 2300 mm. (iii) Free board for back wash - 50%. (iv)Materials - MS. (v) Thickness in mm (shell and dish-ends) - 8-10mm. {Note:-- Rate deemed to be included with the followings:-(a)Raw water and treated water tested report of all parameter from National Test House Salt Lake. (b)Training to DEL Staff with required material and maintaining log book and other register as directed. (c) Electronic flow meter-01 including necessary wiring complete. (d)Butter fly and gate valves as required.(e) 2 Nos air compressor of capacity 210 CFM with 3 Phase Motor, Starter, air pipe connection including electrical connection complete. 70 Supply, install, lowering, testing & commissioning of submersible pump set 8 stage, suitable forminimum head 40 Mtr with 635 lpm dischage with electric driven motor of capacity 15 hp, 415 V AC, TP with operational efficeiency performance and durability wide voltage range 350-440 Volts, super finished water lubricated bush bearing, with less speed drop motors with reflon bearing and sand guard complete all as specified and directed by Engr-in-charge. 71 Trail drilling of bore of size 250 mm dia upto 120 mtr depthby direct rotary/ DTHmechanical system for injection wellin any kind of soil strata including hard stone/boulders and submitting the strata detail both graphically recorded as well as strata results including testing of yield , complete all as specified and as directed. 72 Reaming of bore well from 250 mm dia to 525 mm dia hole in three steps from 250 mm to 350 mm, 350 mm to 450 mm and 450 mm to 525 mm dia bore siutable for lowering ERW Mild steel casing pipes and gravel packing for the required length (i.e 50 mtr depth) below the ground level , complete all as specified and as directed. 73 All as per item no 13.41 here-in-before but exceeding 50 mtr and upto 170 mtr depth, complete all as specified and as directed. 74 Supply, assembling, lowering and fixing in position 250 mm nominal (10) bore ERW MS housing pipe, ISI marked,of 8 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth upto 40 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding , complete all as specified and as directed. 75 Supply, assembling, lowering and fixing in position 200 mm nominal (8) bore ERW MS housing pipe, ISI marked,of minimum 8.0 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth exceeding 40 mtr and upto 120 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding, complete all as specified and as directed. 76 Supply, assembling, lowering and fixing in position low carbon galvanized (LCG) steel strainer pipe 200 mm nominalbore of wall thickness 7.00 mm cagetype wire wound screen ‘V’ shaped profile in suitable length having slots of size 1.6 mm width including necessary end coupling,electric Arc welding as required and including special sockets for connecting to MS pipe, complete all as specified and as directed. 77 Supply and fixing mild steel reducer suitable for (250 x 200 mm ) bore casing pipe, 10 mm thick, fitted to casing pipe as per IS 2800 by means ofelectric Arc welding ,complete all as specified and as directed. 78 M&L for carrying out electro logging test upto complete drilling depth of tube well for fixing water strata and submitting of Report including its interpretation by a qualified Hydrologist/ground water expert , complete all as specified and as directed. 79 S&Fmild steel bail plug assembly suitable for 200 mm bore casing pipe internal threaded with strong iron hook, screwed and welded to casing pipe as per IS 2800 , complete all as specified and as directed. 80 Supply, filling and packing washed pea gravels of size 2 mm to 4.6 mm all around casing pipe and slotted pipe, complete all as specified andas directed 81 S&F mild steel housing clamps 1200 mm long 100 mm wide , made out of 20 mm thick MS plate made to shape for 250 mm bore casing pipe with necessary bolts, nuts and washers at ground level, complete all as specified and as directed. 82 Developing of tube well by means of air compressor, for number of hours, until sand free clear potable water is obtained including testing by using diesel engine driven turbine pump to get maximum yield and discharge including supply of yield test result , complete all as specified and as directed. (Note : The rates of DHPP is inclusive in the quoted rate) 83 S & F well cap made out of 5 mm thick MS Plate with provn of suitable holes for passing two runs of flat 3 core PVC insulated sumersible cable motor and one run of SWR, 100 MM dia column pipe and suitable for fixing 250 mm nominal bore ERW heavy duty MS of 8.0 Mm Wall thickness casing pipe complete all as specified andas directed. 84 S&F pressuregauge with isolation cock suitable for a working pressure of 7 Kg/cm² (Liquid based High Intensity), complete all as specified and as directed. 85 Supply and laying flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work , complete all as specified and as directed. 86 S&F round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed ,complete all as per directed. 87 Supply , lowering and fixing MS column pipe 100 mm bore, medium grade, confirming to IS, 3 meter long pipe both end flanged, threading, welding and drilling of holes, cutting of ducts of size 10 mm x 20 mm 2 No. in each flange for fixing submersible cable, including rubber gasket of suitable size, nuts, bolts, washer etc including painted internally and externally with two coat of non corrosive non toxic bituminous paint including making all type of connections as required, complete all as specified and as directed. 88 Supply , install, testing and commissioning of cubical housing cabinet type weather proof powder coated LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proofof CPRI approved,openablefrom both front and rear side made of2 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- 89 (i) Aluminium Bus bar 160 Amps -25 KA breaking capacity(ii) Incoming MCCB, 4 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacityQty 1 No(iii) Outgoing MCCB, 3 pole, 32 Amps, 415 Volt AC, 10KA rupturing capacityQty 4 Nos(03 For submersible pump and 01 standby)(iv) Outgoing MCB 4 Pole 32 Amps, 10 KA, 240 Volts - 01 Nos(v) Star delta motor starter suitable for 15 HP motor pump - 03 Nos(vi) LED indicating lamps - 03 Nos(vii) Digital Volt meter (Size - 96 x 96mm) 0-500 Volts with selector switch - 01 No(viii) Digital Ammeter (Size96x96mm) With selector switch including CT ( 100/5Amp) with all connection- 01 No(xiv) Matering and accessories complete all as directed by Engr-in-Charge. 90 Supply, installation, commissioning and testing of 200mmsluice valveof cast iron body flangedconforming to IS-14816, PN-1.6 Non rising type spindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 91 Supply, installation, commissioning and testing of 150mmsluice valveof cast iron body flanged conforming to IS-14816, PN-1.6 Non rising typespindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 92 Material and labour for Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 93 Material and labour for Construction of brick masonry valve pit of internal dimension 60 cm x 60 cm x 60 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 94 Supply, install, testing & commissioning of Centrifugal pump suitable for minimum, Discharge 635 LPM at 30 Mtr head with cast iron casing, bronze impeller, SS Shaft, electric driven motor of 10 HP, 415 V, TP suitable for under ground sump and install complete including PCC foundation as per manufacture instruction complete all as specified and directed. 95 Supply, install, connecting, testing & commissioning of high pressure single head adjustable chemical dozing system of the folowing specification : (a) Adjustable high pressure 100 PSIG Power input 230 V, 50 HZ, Max flow rate 02 US GPD to 40 US GPD with mandatory assecceries like lead tubing connecting ferrules, check valves, 170 ltr FRP solutin preparetion tank with lid, port hole, inlet/outlet/drain connection, level guage ete and fitted with 900 RPM motor PVC agitator combined with 100 ltr dosing tank lid port hole inlet/outlet/drain connection, level guage etc either fitted with 900 RPM moter and PVC agitator complete all as speficified and directed.Make : Any make of E-in-C approved or ISI Marked of any make as approved by Accepting Officer. 96 Supply and laying DI Pipe 200mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 97 Supply and laying DI Pipe 150mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 98 M&L DI Fittings bends (any type radius and angle) tapers any type, (straigth, bend, increasing, decreasing or double socket etc) Tee pieces single branch Y junctions double branch, cross (all sockets or socket and spigout ) collars, caps and plugs upto 300 mm bore complete all as specified and directored. 99 (EXTERNAL ELECTRIC SUPPLY)suply , installation and commissioning of compact secondary substation (CSS) 315KVA comprising to following parameters:-(a) Housing to made with conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to high voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lighrening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h) Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside fo the CSS.(l) Necessary HT and LT cable / earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 100 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs adn PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet enclosure with automatic sagety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch. 101 (vii)Shunt trip coil- 230 V, AC(viii) Safety interlock locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, space heater with thermostat, fuse adn ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle(xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 315 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 25.% on HT side all technical specification comprising to IS 11171 update version part with all necessary satndard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 315 KVA (ii)Primary Voltage - 11 KV AC(iii) Secondary Voltage - 433 Volts . 102 (iv)Neutral earthing should be solidly earth system (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs). q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 103 Suply , installation and commissioning of Compact Secondary Substation (CSS) 250 KVA comprising to following parameters :-(a) Housing to bemade with Conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to High voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lightening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h)Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside of the CSS.(l) Necessary HT and LT cable / Earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 104 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs and PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch.(vii)Shunt trip coil- 230 V, AC(viii) Safety Interlock Locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, Space heater with Thermostat, Fuse and ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle. 105 (xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 250 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 2.5% on HT side all technical specification comprising to IS 11171 update version part with all necessary standard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 250 KVA (ii)Primary Voltage - 11 KV AC 106 (iii) Secondary Voltage - 433 Volts (iv)Neutral earthing should be solidly earth system. (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance.(p)LT Panel for 250 KVA Transformer made with 2 mm CRCA sheet with necessary angle iron frame and vermin proof font side openable double door with necessary locing arrangement opening for bus bar / cable entry opening for natural air ventilation / cooling necesary Ammeter, Voltmeter, Selector switch, CTs , suitable size bus bar, paints and primer with Air Circuit Breaker (ACB) as incomer 630A, 50 KA, 415 V , AC, 50 Hz, 4 Pole with neccesary setting and microprocessor control draw out type bus bars, as outgoing MCCB 200 Amps, 35 KA - 02 Nos, MCCB 160 Amps, 35 KA - 02 Nos & 32 A MCB 4 Pole - 04 Nos. (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs).(q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 107 Supply and fixing LED street light fittings on ploes capacity 45 Watts, high pressure die cast aluminum housing IP 66 rating front cover made of toughened clear glass, suitable for pole mounting wih bracket arm 40mm dia, Gl light grade pipe upto 1.4 m long, bend to required shape, clamp 40mmx6mm or required length including nuts & bolts fixed on steel poles complete all as specified.Model No : ENDURASUNDOWNSL45WLED765PASYBOTG of make : Havells or equivalent make as per Appendix D. 108 Supply & Fixing junction box with 3 Phase terminals and size of box 130mm x 180mm x 77mm or nearest higher size made of polycarbonate with IP 66/67 degree of protection, dust proof, water tight,shock proof, fire retardant,with internally embedded gasket fitted with heat treated bakelite for terminals block and PVC Glands for cable entry complete all as directed 109 M&L Three core 1.5sqmm(nominal area)service wire PVC insulated copper conductor FRLS, multi stranded, unsheathed 1100 volts grade IS-694 marked andfrom junction box to street light fitting through steel pole withPVC conduit & necessary clamps, bolts & nut etc required for fixing complete all as specified and directed. 110 Supply , install, testing and commissioning of cubical housing cabinet type conforming toCPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowings :-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -200 Amps , cable entry (incomming and outgoing ) form bottom with cable gland Incomming : 125 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No (Incoming from CSS)Outgoing -(a) MCCB 4 pole 100 Amps 25 kA - 02 Nos (for signal unit and 1 standby)(b) MCCB 4 pole 16 Amps 25 kA - 2 Nos (For OFFR Living ,meter or switch house and and 01 No for street lights)(c)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor(d) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) LED indicating lamps -03 Nos 111 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -400 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 250 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 200 Amps 35 kA - 01 Nos (Adm buidling)(b) MCCB TPN 16 Amprs 25 KA-02 Nos (Guard house and standby)(c) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(d) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No(e) LED indicating lamps -03 Nos. 112 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approvedLT panel board Outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -600 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 315 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 125 Amps 35 kA - 03 Nos(02 Nos for OR Accomodation and 01 Nos standby)(b) MCCB 4 pole 63 Amps 25 kA - 01 Nos(JCO Accomodation and JCO Club) (c) MCCB 4 Pole 25 Amprs 25 KA - 01 Nos (Drying and ironing room)(d) MCCB TPN 16 Amprs 25 KA - 02 Nos (Street lights and one standby)(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos (g) LED indicating lamps -03 Nos (h)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor 113 Supply, install, testing and commissioning of Automatic Power Factor Correction (APFC) panel board of aggregate capacity 15 KVAR suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, outdoor type, cubicle, floor mounted, free standing dust and vermin proof, air ventilation made out of 3 mm thick CRCA sheet duly powder coated, Manufactured shall be CPRI norms and as approved by GE, factory made.Panel board shall have front and rear opening with hinged type doors and rubber gasket, handles, industrial type locking arrangement, cable alleys, switch gear compartment, bottom cable, entry holes for incoming and outgoing cables, earthing terminals, danger notice plate, Aluminum bus bar duly covered with heat shrink sleeves of colour coded duly fixed on DMC / SMC insulators housed in a separate bus bar chamber including control wiring with PVC insulated, flexible, multistranded copper conductor cables of adequate size and of adequate length for connecting of capacitors, contactors etc duly ferruled crimped with suitable lugs / thimbles and including connecting of incoming and outgoing cables. Panel board shall be mounted on and including MS angle iron frame of suitable size duly painted and PCC1:2:4 type B1 for foundation / Platform to suit the site requirement complete all as specifiedand directed and comprising of following:-(i) APFC relay microprocessor based digital display type of 9 stages suitable for operation of PF upto unity – 01 No. 114 (ii) MCCB 320 Amps, 4 pole, 50KA, 415V, 50HZ – 01 No for incoming.(iii) MCCB 80 Amps, 4 pole, 25KA, 415V – 03 No’s for capacitor outgoing.(iv)MCCB 40 Amps, 4 pole, 25KA, 415V – 01 No for capacitor outgoing.(v)MCCB 16 Amps, 4 pole, 25KA, 415V – 05 Nos for capacitor outgoing(vi) MCB SP 0.5 to 5 AMPS, ‘C’ Curve, 240V-09 Nos as per circuit control.(vii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -05 Nos.(viii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -02 Nos.(ix) Capacitor Bank 1 KVAR, 3 phase, 440V MPP type including suitable rating contractor -01 Nos. 115 (x) LED indication lamps RYB – 01set.(xi) Auto / manual selector switch -01No.(xii) Push button and indication lamp for each capacitor bank -01 set.(xii) Digital voltameter with selector switch -01set.(xiv) Digital ammeter with selector switch & CT’s -01.(xv) Aluminium bus bar TPN 480 Amps rating -01 set.Note: The contractor should be factory inspection and drawings approval by the GE / Engineer-in-Charge before procurement after commissioning of APFC panel the power factor (PF) to achieve 0.95 to 0.99 mandatory at any load condition automatically. 116 Supply and fix solar street light smart integrated solar system all in one with MPPT (Maximum Power Point Tracking) charge controller ,Tilable LED Panel,Adjustable AIO mounting angle ,mono crystalline solar panel ,PIR motion sensor, and 6m tubular pole with 30 wattLED light at a rate 100 lm/w, 60wp, 75 AH (Lithium ferrous phosphate battery luminaries must have a life of greater than 50,000 hours and have IP 66 rating, the modules are to bedesigned to with stand corrosive atmosphere and heavy wind loads. the modules are to be certified for standers IEC 61215, IEC 61730 (Safely class I & II) complete all as specified and directed. 117 Supply and fix LED post top lantern decorative typeo fttings for 360 degreee indirect light on pillars of capacity 40 watts high pressure die cast aluminium housing IP 65 rating, suitable fr mounting 40 dia GIlight grade pipe upto 0.5 m long or required length including nuts and bolts and fixed complete all as specified and directed.Model No : RUBYPT40WLED757PSYMTOPC OF MAKE : Havels or equivalentmake as per Appendix D 118 M&L fpr boring holes horizontally under road without damaging the surface of road (minimum 1 mtr below the road surface/ footpath with the help of GI tubing not exceeding 100mm dia bore for passing of UG cable complete all as specified and directed. 119 (REFGIGERATION & WATER COOLER) Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 308 - 315 ltrs capacity, conforming to IS 15750 (2006) for frost free, with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 120 Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 192 - 210 ltrs capacity, conforming to IS 1476 for direct cool with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 121 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 320 ltrs, BEE 5 star rating complete all as specified and directed. 122 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 400 ltrs, BEE 5 star rating complete all as specified and directed. 123 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacityof 40 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 124 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 120 ltr and nominal cooling capacityof 60 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 125 S & F Voltage stablizer of capacity 2 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 126 S & F Voltage stablizer of capacity 1 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 127 (DG SET) M&L Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected tousing galvanised iron strip 32×6mm as earthing lead earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated by Engr-in-charge including testing on completion. 128 Supply and installation testing and commissioning silent Diesel Enginegenerating set 415 volts 40 KVA3 phase 0.8 power factor, 50 Hz, 1500RPM self exicited self regulated brushlessAC generator installed including AMF panel,suitable for ambient condition at Panagarh and confirming to condition under ISO 3046, IS:10001/ 10002,BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :- (A) Alternator:- Synchrounous alternator rated at 40 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system.The alternator shall be brushless, single bearing, self excited/ self regulated with an AVR. The alternator will be suitable for climate and shall generally confirm to IS: 4722 :2001. The salient features of the alternators are :- (a) +-1% voltage regulation (max) in static conditions.(b) IP:23 protections with class H insulation.(c) Permanent lubricating bearing. 129 (B) Diesel Engine:- Adquate capacity of diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500RPM, as per relevant IS/BS complete with standard accessories. (C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent (to comply GRIHA and other agencies norms) canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimentional accuracy of holes within 0.1 mm.Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility (D) AMF panel : Automatic Mains Failure (AMF) panel made of CRCA sheet of 2 MM thick including necessary arrangement to install, testing and commissioning & connecting ot load cable to up ot changeover switch, suitable capacity of 4 pole MCCB complete all as per OEM recommendation.(E) Civil Works :- All civil works including PCC platform and related foundations incl for panel and equipments incl making goodof disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommendedby the manufacturer. 130 (F) AMF Panel Specification shall be as per manufacture instruction.Note :-The contractor shall be arrange for artificial load resistive for testingof DG set at site and the cost is deemed to be included in the quoted ratesMAKES :- Make of engine : CUMMINS/KIRLOSKARGREEN/ASHOK LEYLAND/ GREAVES COTTON.Make of alternator : KIRLOSKAR GREEN / ALSTOM / CROPTON GREAVES /SIEMENS 131 Supply, erecting,testing aand commissioning of solar water heating system with heat exchanger for cold & warm regions respectively with solar evacuated tube collection conforming to IS : 12933 (Part - i ) with amdt No 1 and IS : 12933 (Part 2) /2003 suitable for inlet water with chlorine and fluorine content up ot 100 ppm and supply hot water at the outlet of 200 litters capacity with elctrical back up meeting specifications as under and comprising of followings :-Supply and fixing rotational moulded polyethylene water storage tank (Cylindrical Vertical with closed lockable top with lid and locking arrangement) hoisted and fixed in position all as specified in SSR Part -I of capacity 200 Litters complete for storage of cold water feeding to solar water heater, including staging made out of MS Angle iron 50x50x6 mm all as specified and directed at site by Engineer-in-Charge.Material :- Soalr water heating System : Comprising of solar Evacuated tube Collector, Collectors stand assembly.Staniless steel insulated hot water Storage tank with heat exchange and various other components . Solar evacuated tube collector component shall have :Evacuated tube collector component shall have : solar Evacuated tube collector cover plate made of toughened glass.Sheet for absorber made of copperAbsorber made of copper sheet and copper tube.the minimum thickness of Aluminium shall be as under:- (a) Channel section for sides 1.6mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm sheet for entire body 1.0 m AbsorberAbsorber shall consist of riser, header and sheet for absorer. The diameter of header shall be 25.4 +/- 0.5 mm and thickness 0.71 mm. The Diameter of riser shall be 12.7 +/- 0.5 mm and thickness 0.56 and made of copper only. 132 S & F Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed. 133 Rain water Harvesting /Recharge PitS & F 150 MM perforated UPVC pipe with 20% Perforation complete all as specified and directed. 134 S & F 150mm bore PVC (SWR) vent cowl complete all as specified and directed. 135 M&L for hand packed gravel (Stone chips 12.50mm) for filling in bore holes and inside of recharge pit complete all as specified and directed. 136 Boring for 350 Mm Dia bore to a depth of 40 mtr in soil and getting out and disposal of spoil to a distance of 50 mtr using DMC method ( Direct mud Circulation) complete all as specified and directed. 137 GRIHA RATING FOR FOLLOWING BUILDING:-Minimum 3 star GRIHA rating shall be obtained for the following buildings which includes pre-certification and final ratings from approved aggency(a) OFFICER/ ADMIN BLOCK (b)SINGLE living JCOs ACCN(c) SINGLE living HAV/OR ACCN (T/S)Note :- 01The GBA (Green Building adviser) ofr obtaining GRIHA certification shall be approved by Accepting Officer.02. The GBA shall be responsible for all necessary actions for obtaining final GRIHA rating as per following guide lines:- (a) Pre-Cretification :-1. Submission of GRIHA per certification documents to certification agency as applicable immediately after the issue of Job/Work order.2. Analysis and suggest improvement/correction in the MEP/Other relevant drawings/documents and draft tender of the subject work for GRIHA star Rating (Min Three Star).3. Preparation, Submission & uploading all the documents in accordance with the GRIHA requirment, documentation shall be supported by drawings, test result quipment catalogues & calculations.4. Selection of equipment & material.5. To facilitate the planning team for selection of appropriate energy efficient & eco -friendly technologies, equipment & materials for the building e.g lighting system ,white goods, water treatment technologies, renewable energy, nontoxic paints, rapidlly renewable materials, recycled materials, ecofriendly materials etc.6. preparation of vendors & suppliers list for inclusion in the tender & working out specification of equiptment & materialto suit the GRIHA requirement. 138 7. Develop templates for GRIHA calculations to achieve certain points, this include materials related criteria, construction of waste management at site, energy calculation etc.8. conduct solar path analysis for each to achieve the best design ( shading device, Orientation etc.)9. Conduct solar path analysis for each fenestration to achieve the best design ( shading device, orientation etc)10 Perform day light analysis to ensure optimun condition achieved as per the guidelines provided by ECBC 2007.11. Perform day light analysis for window -wall ration, glass peropertiies (SHGC) & Providing recommendations to meet the compliance of ECBC 2007.12. Perform hourly calculation to show that thermal comfort condition as well as non-condition area are cachieved.13. Perform energy simulation to predict the energy performance of energy system in the bldg is less than the benchmarked energy perfomance as prescribed by GRIHA.14. Submit of ECBC compliance document to show that compliance fo mandatory requirment of ECBC are meet.15.Submission of draft specification to comply with relevant criteria of GRIHA for inclusion in tender documents.16. Liasoning and coordinating with GRIHA team for registration of project, uploading relevant document. Responding ot queries, observations, modification and corrections given by GRIHA team within specified time framed and reporting client with lates update.17. completion of all documentation requirement and formatlities before conclusion of main bldg. Contract and obtaining pre-certification with 3 or above star rating. 139 Final Rating:-Acquiring of Final Post GRIHA (minimum 3 star rating) certification approval from GRIHA including changes in drawings/ design during execution of work.Note:-The consultancy fees is inclusive of the following:-1. Pre-certification Registration Fees2. Certification registration Fees3. Site visit of GRIHA Official4. Site visit of GRIHA Official5. Third party EvaluatorPayment Schedule :-(i) 10% after pre-certification(ii) 50% at finalisation of specification(iii) 40% after obtaining GRIHA certification 140 Providing and fixing white vitreous china floor mounted water closet of size 360X640X685 mm of approved shape including providing and fixing vitreous china cistern with duel flush fitting, of flushing capacity 3 litre/6litre (adjustable to 4litre/8litre, including seat cover, and cistern fitting nuts, boltsand gasket etc complete all as specified and directed.Model No: SLS-WHT--6851P of make Jaquar of equivlent make/model as specified in Appendix D. 141 Providing and fixing white vitreous china wash basin for under counter mounting, specially fabricated brackets, painted whit, brass tap, 32 mm C.P. Wast, 15mm C.P. Brass self closing tap, connection pipe & rubber adopter for waste connection, complete including cutting and making food the walls, wherever requird complete all as specified and directed.Cat No : CNS_WHT_705 for wash basin ofmake Jaquar& Cat No PRS-031 for 15mm C.P brass tapof make Jaquar or equivlent make/model as specified in Appendix D. 142 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. Size 485 X 310 X 710 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction of Engineer-in-Charge.Cat No : URS-WHT-13255 of make of equivlent make/model as per Appendix D 143 Providing and Fixing of P.V.C waste Flexible pipe 40mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 144 Providing and Fixing of P.V.C waste Flexible pipe 15mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 145 Providing and fixing C.P. Brass angle valve 15mm dia for basin mixer and gyser pointsconforming to IS : 8931 complete all as specified and directedCat No FLR-CHR-5053N of make of equivlent make / model as per Appendix D. 146 Providing & fixing Liquid soap container of standard shape with bracket of the same material with snap fitting of approvedquality and colourcomplete all as specified and directedCat No : CAN-1135N of make of equivlent make / model as per Appendix D 147 Provinding & fixing Sink cock 15mm nominal bore of approved quality and colour complete all as specified and directedCat No : FLR-5347ND of make of equivlent make / model as per Appendix D 148 Provinding & fixingCP Brass Health faucet with 1.5M S.S Flexible Tube with wall hook including screw, Nut, bolts, cutting wall/floor and making good the same whatever required complete all as specified and directedCat No : ALD-CHR-583 of make of equivlent make / model as per Appendix D 149 Provinding & fixingCP Brass Bid cock Including wall fange, Connections, screws, nut, bolts, cutting wall/floor and makiing good the same whatever requiredcomplete all as specified and directedCat No : FLR 5037Nof make of equivlent make / model as per Appendix D 150 Provinding & fixing sink CP Wall mount double Robe Hookfixed to wooden cleats with C.P Brass screws, cutting wall/floor and making good the same whateverrequired complete all as specified and directedCat No : CAN-1161N of make of equivlent make / model as per Appendix D 151 Providing and fixing of straight type Macfit Single body push fit type WC pan connector with factory supplied srpring loaded seal guard of mcalpine, UK with integral single mould sealing fins made of flexible eva body, including bush/ adaptor for use with C.I pipe as supplied with the pan connecrtor complete all as specified and directed. Model : MAC 1 of make Macalpine of equivlent Model as approved by E-In-C or Accepting officer. 152 HOT WATER SUPPLYSupply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 15 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 153 Supply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 25 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 154 S&F CP Brass stop cock (concealed) of 100mm dia of standand design conforming to 15:8931 complete all as specified and directed. 155 Providing and fixing sound insulated PP piping system as per ON EN 1451 _ Part I-6 & EN 12056 part I-5 with 3 Layer pipe made of PP-C +PP-MV+PP-C in Blue Ral 5014 (Halogen and calcium free) colour, Push-fit type, food safe having high impact and stiffness, offering sound level of not more than 22dBA at a flow rate of 4 I/S and having pipe ring stiffness as per ISO/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560 with all necessary fillings in blue colour, filled with factory fitted lip ring of make : Polyplast or equivalent make as approved by GE suitable for PP110mm dia Pipes complete all as specified and directed. 156 All as per item No 14.24 here-in-after but for PP 75mm dia pipes 157 All as per item No 14.24 here-in-after but for PP 40/50mm outer dia meter pipe (For wash basin etc) 158 Providing and fixing floor trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connection, 110mm inlet& 110m outlet long hight complete all as specified and directed. 159 Providing and fixing 110 X 50mm UPVC Floor Drain / Plain Floor trap complete all as specified and directed. 160 Providing and fixing SS Grating Over Floor Trap& Floor Drain 127 X 127mm complete all as specified and directed. 161 M&L concrete bed to drain pipe including packing under and lacking against the side of pipe after they are laid and tested with PCC (1:4:8) type D-2, for 110mm dia complete all as specified and directed. 162 All as per srl item No 14.30 here-in-after but for PP 40/50mm outer dia meter pipes. 163 S&F clean out cap plug (FCO/COP) for cleaning of same materials (POLO KAL NG) for PP 110mm dia complete all as specified and directed. 164 S&F 3-layer PPR-polypropylene random copolymer conceled pipes SDR 7.6 (PN-16) UV stabilized and antimicro bial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting for 50mm outer dia laid in trinches complete all as specified and directed.
Contract Date: Mar 17, 2026 Contract Value : 59.85 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
West Bengal View Result →
Contract Date: Mar 09, 2026 Contract Value : 19.82 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Maharashtra View Result →
22.
Defence #9724960 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Ship; Defect Rectification Of E-575,E-576,E-580 And E-595; E-575 Following system valves not holding pressure and leaking:- (a) Fire hydrant valve at AER – 01 no ( 80 mm SDSL) and Fire main supply butterfly valve at main alleyway to Q-deck/ ASP – 01 no (80 mm, butterfly valve). (b) Port ref condenser inlet ball valve - 01 no (32 mm, Ball valve) (c) Ref condenser pump (Stbd) discharge & suction valve – 02 Nos (32 mm SDSL & ball valve) (d) Aft AC condenser pump discharge valve – 01 no (150 mm, SDSL valve) All valves to be overhauled, pressure tested (TP-05 bar) and proved for satisfactory operation. No. 01 E-576 DA no 2 & 4 sea chest strainer (02 each) deteriorated and foreign material are chocking in heat exchanger. Strainers to be repaired/ renewed as per sample. Material- SS, Height- 250 mm, Dia- 60 mm Total Quantity- 04 nos No. 01 E-580 Educator bilge suction valve at ASP compartment for void space below 32 rating mess (Qty- 02 nos, 65 mm SDSL) not holding pressure. Same to be overhauled, pressure tested (TP-05 bar) and proved for satisfactory operation. No. 01 E-595 Various System Pipe Lines observed to be excessively corroded and deteriorated at various places. In way jobs include renewal of following pipelines as per sample (including all joints and fasteners) and proving of system:- (a) Fireman System Pipe Line in FER Compartment (Dia - 85 mm, Length - 3 m, Mat - Cu-Ni) (b) Fwd WHR Discharge Pipe Line in FER Compartment (Dia - 85 mm, Length – 3.0 m, Mat - MS) (c) Calorifier Inlet Pipe Line in AMR Compartment (Dia - 40 mm, Length – 2.0 m, Mat - Cu-Ni) No. 01
Contract Date: Ref. Documents Contract Value : 1.25 Lakh
Government Departments No of Bidders 3
Contract Date: Feb 25, 2026 Contract Value : 17.01 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Maharashtra View Result →
25.
Defence #9640111 AOC
Tender For Provision Of Otm Accommodation For Med Regt (Phase-I) At Jammu Under Ge Satwari.; 1 Construction of Singles living Accn for Havs/ORs (Double Storey),complete all as specified and shown on drgs 2 Construction of Cook House & Dining Hall(Single Storey) for Havs/ORscomplete all as specified and shown on drgs 3 Construction of Administration Building(Double Storey) complete all as specified and shown on drgs 4 Construction of EducationBuilding(Single Storey) complete all as specified and shown on drgs 5 Construction of Night Pickets with Guard Room (Single Storey),complete all as specified and shown on drgs. 6 Construction of Singles Living Accn for JCOs (Double Storey), complete all as specified and shown on drgs. 7 Construction ofJCOs Club/Mess (Single Storey), complete all as specified and shown on drgs. 8 Construction ofParking Shed for JCOs (Single Storey), complete all as specified and shown on drgs. 9 Construction of Singles Living Accn for Officer (Double Storey), complete all as specified and shown on drgs. 10 Construction ofServant Quarters for Officers (Double Storey), complete all as specified and shown on drgs. 11 Construction ofCar Garages for Officers (Single Storey) including Apron, complete all as specified and shown on drgs. 12 Construction of Storage Accn (Gen Store)(Single Storey) complete all as specified and shown on drgs. 13 Construction of Parking Shed (Single Storey) for ADM Bldg, complete all as specified and shown on drgs. 14 Construction of Sentry Box, complete all as specified and shown on drgs. 15 Construction ofElevated Sentry post,complete all as specified and shown on drgs. 16 Construction of Flag Staff with base complete all as specified and shown on drgs 17 Construction of Incinerator complete all as specified and shown on drgs. 18 Construction of Garbage bins/Refuse bin complete all as specified and shown on drgs. 19 Construction of Fire Points complete all as specified and shown on drgs. 20 Septic tanks with excavation in foundations in any type of soil, PCC bed, Fly Ash brick work including sludge chamber, septic tank designed to carry sewage and sullage water, vent shaft& connection etc for 20 users complete all as specified and as shown in drawings. 21 RCC Septic tank for 100 Users (With UPFLOW FILTER)designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter,.complete all as specified and as shown in drawings. 22 Soakage well, conventional type,with excavation in any type of soil, PCC 1:3:6in foundation, walls of honey combed Fly Ash brick masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Fly Ash Brick masonary in cement mortar, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats,size of soakage well 1.2mtrdia X 3mtr deep effective depth,. complete all as specified and as shown in drawings. 23 Soakage well excavation in any type of soil, foundation in PCC 1:3:6, walls of fly Ash honeycombed masonry, and slab in M-25 concrete including intercepting chambers, screen chambers, brick work in CM, RCC cover slab in M-25 filling with brick bats complete of size 1.8 mtr dia3.00m deep,.complete all as specified and as shown in drawings. 24 Lumpsum price worked out by the contractor for Internal Water Supply Works as listed in Schedule A Part-II. 25 Lumpsum price worked out by the contractor for Internal Electrification Work as listed in Schedule A Part-III. 26 Lumpsum price worked out by the contractor for Plumbing Works as listed in Schedule A Part-IV. 27 Lumpsum price worked out by the contractor for Site ClearanceWorks as listed in Schedule A Part-V. 28 Lumpsum price worked out by the contractor for Protective Works as listed in Schedule A Part-VI. 29 Lumpsum price worked out by the contractor for Area Drainage Works as listed in Schedule A Part-VII. 30 Lumpsum price worked out by the contractor for Chain Link Fencing Worksas listed in Schedule APart-VIII. 31 Lumpsum price worked out by the contractor for Sewage Disposal Works as listed in Schedule A Part-IX. 32 Lumpsum price worked out by the contractor for Road, Path & Culverts Works as listed in Schedule A Part-X. 33 Lumpsum price worked out by the contractor for Connecting Passage Works as listed in Schedule A Part-XI. 34 Lumpsum price worked out by the contractor for External Elect Supply Works as listed in Schedule A Part-XII. 35 Lumpsum price worked out by the contractor for External Water Supply Works as listed in Schedule A Part-XIII. 36 Lumpsum price worked out by the contractor for Lightening Protection Works as listed in Schedule A Part-XIV. 37 Lumpsum price worked out by the contractor for Air Conditioning & Desert Cooler Works as listed in Schedule A Part-XV. 38 Lumpsum price worked out by the contractor for Solar Water Heating Works as listed in Schedule A Part-XVI. 39 Lumpsum price worked out by the contractor for Water Cooler & RefrigerationWorksas listed in Schedule A Part-XVII. 40 Lumpsum price worked out by the contractor for Demolition& Dismantling Works as listed in Schedule A Part-XVIII. 41 INTERNAL WATER SUPPLY Chromium plated cast copper alloy shower rose square type of size 120mm x 120mm with 195mm long arm15 mm bore having 45 degree bend with brass flange,complete all as specified and as directed. 42 Chromium plated cast copper alloy sinkmixer 15 mm bore screwed down Wall mounted type, withswan neck swinging spout for mixing hot and cold water fixed to iron pipecomplete all as specified and as directed. 43 Chromium plated cast copper alloy wallmixer for mixing hot and cold water 3-in-1 quarter turn type with provision of over head shower systemscrewed downfixed to iron pipe of 15mm bore, complete all as specified and as directed. 44 Chromium plated cast copper alloy Pillar tap long body with swan neck type, screwed down high pressure capstan heads with or without lettered Hot or Cold with long screwed shanks and cups fixed to iron pipe of 15mm bore, complete all as specified and as directed. 45 INTERNAL ELECTRIFICATION DBOXX MCB protected socket with sheet steel enclosure single pole, 25 Amp with 3 pin plug top for AC connection from Socket point to stabilizer, complete all as specified and as directed.Make:- Havells Cat No-25 A MCB DBOXX COMBO or its equivalent in Anchor/L&T. 46 LED Lamp 10 Watt B-22 with holder base polycarbonate body and aluminium heat sink warm white,complete all as specified and as directed by Engineer-in-Charge.Make:- Havells Cat No-25 A MCB DBOXX COMBO or its equivalent of Anchor/L&T. 47 High performance IP-66 LED Streetlight 25 Watt, housing made of die-cast aluminium, with street optic lens, with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5 Sqmm from ceiling rose to 25 W LED light etc. and including 32mm bore GI light grade protection pipe upto i length suitable fixing accessorieson walls, complete all as specified and as directed by Engineer-in-Charge. 48 PLUMBING ITEMSUPVC(SWR),heel rest bend for 110 mm bore complete all as specified and as directed by Engineer-in-Charge. 49 CHAIN LINK FENCEConcertina coil fencing with punched tape concertina coil 600 mm dia, streched to 6 meter length, having 50 Nos spiral turns per 6 meter lengthy, spring core wire (2.59mm thick) of high tensile strenth of 1620 N/sqmm with tape (0.52mm thick) Hot dip galvanised upto 20 microns, weight of each coil 8.50 Kg and fixing the same exsiting Y-shaped angle iron with 6 horizontal R.B.T. (Reinforced Barbed Tape) wire, stud tied with G.I. staple sand G.I. clips to retain horizontal, clips shall be @ 5 Nos Per 2 spiral turns approximate 125 clips per coilo including necessary bolts complete all as specified and as directed. 50 ROAD, PATH & CULVERTPreparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instructions, complete all as specified and as directed. 51 Road rummble straight 300mmx 150mm made out of hard acrylic polymers of colour yellow abd black with both side reflector for fixing with suitable bitumin and including fillingPCC 1:2:4 complete good finish surface, complete all as specified and as directed. 52 Road safety 580 mm dia convex mirror with framemade up of H2 polycarbonate reflective mirror having body ABS /fibre suitable for indoor/out door use with hood complete with mounting hardware including suitable height /dia ofMS tubular pipe with painting and grouting with PCC 1:2:4 complete good finish surface, complete all as specified and as directed. 53 Road safety 800 mm dia convex mirror with framemade up of H2 polycarbonate reflective mirror having body ABS /fibre suitable for indoor/out door use with hood complete with mounting hardware including suitable height /dia ofMS tubular pipe with painting and grouting with PCC 1:2:4 complete good finish surface, complete all as specified and as directed. 54 ELECTRIC OPERATED SECURITY BARRIERSupply, Installation, testing & Commissioning of Boom barrier BG100-L 6 Mtr, ESSL photo cell sensor Boom Barrier, ESSL manual switch SW01,with spike and operated push button including wiring and control panel, complete all as specified and as directed. 55 Solid PVC Wall panellling consisting of 5mm thick plain colur PVC sheet fixedon PVC frame, including 5mm thick PVC fillets of width 35 and 5mm palin clour PVC sheet in strips and channel, feathered at edges for fixing solid PVC Wall panelling insulated PVC wall lining ad solid PVC partitions, inclusive of solvent cement,compete all asspecified and as directed. 56 EXTERNAL ELECTRIC SUPPLYSupply, install, testing and commissioning of copper wound step down transformer, outdoor type, oil immersed, naturally cooled ONAN, rated temperature rise in oil & winding 40/45 degree centigrade complete with standard fittings of capacity 500 KVA HT 11 KV, 3 phase, LT 433V, 4 wire, 50 Hz of vector group Dyn-11 with off load tap changing device on HT side to vary secondary voltage from + 5 percent to – 10 percent in steps of 2.5% including cable box on LT side, first fill of new transformer oil having dielectric strength not less than 60KV, suitable mounting rails of appropriate gauge and other standard accessories all as per IS:1180 (Part 1): 2014. Note :- The rate quoted deemed to be inclusive of the following:- (a) Accessories such as oil level gauge, rating and diagram plate, monogram plate, explosive vent with diaphragm, thermometer pocket with thermometer, gun metal drain valve at bottom, Air release plug, inspection cover, lifting lugs, hooks, bi-directional plane rollers, oil temperature indicator, winding temperature indicator, silica gel breather & other standard accessories all as per IS:1180 (Part-1) : 2014 energy efficiency level 3 or as per latest amendment of IS 1180(2014) and losses as per clause No 7.8.1.1 of IS 1180 (Pt-I)-2014 etc. Any other item as per manufacturer recommendations for best function of transformer if required are deemed to be included in quotes rates. (b) The cost of PCC foundation required for installation of transformer shall be measured and paid separately under relevant schedule item. 57 Supply, fixing, testing and commissioning of out door type 11KV, 3 phase, 50 cycle (50HZ) totally enclosed metal clad switch gear panel board with SF6 vacum circuit breaker floor mounted with common copper bus bar, 11KV, 20KA, 630A, outdoor type 1-way (1 nos load breaker switch, 1 pcs Modules, 12 KV-28KV-1 Min, rated current bus bar 630 Amps compact, rated current cables switch discharge, 630A, short time withstand current (3 sec) cable switch disconnector 20 KA, short time withstand current (3 sec) vacum circuit breaker 20KA, rated current for Transformer T-off: 630A, impulse withstand voltage: to earth and between phases : 75 KV, insulation level power frequency 1 min 28 KV complete with following accessories.Make - ABB or equivalent 58 Incoming No. 1 (Load Breaker switch C, 11 KV 630A)a) Safe ring type C cable switch 12KV, 630A, 20KA-01No. HT Compartment-Circuit breaker T)- Breaker Modules.b) Snap action mech for manual operation -01 No.c) Cable bushing 400 series bolted 630 A,standard-01 Nosd) Capacitive voltage indication fixed type VPIS 9-15 KV -01 Noe) Fault passing indication - 01 nosOutgoing (V)11 KV, 630A T off to Transformera) Safe plus V is a vaccum circuit breaker modules with vaccum circuit breaker, three position isolator/earthing switch, bus bars, interlocking, earth bar and stored energy mechanism (A-Mech)b) Safe plus type V: Fix type vaccum circuit breaker 12KV, 630A, 21KA, stored energy Mech for man operation -01 No. 59 c) Manual operation-01 No.d) Protection relay (50-51N-51N) microprocessor self powered relay with O/C & 1E/F, Make- Ashida/Equivalent -01 No.e) Ring core current transformer for protection relayf) Ring core current transformer for meteringg) Cable bushing 400 series bolted, 630A-01 no.h) Arc proof cable cover completed incl. interlocking -01 No.j) Capacitive voltage indication fixed type VPIS 9- 15 KV Multi function meter (EM6436/equivalent) - 01 No.H-3 Metering Modules as Bus PT-Ma) Safe plus M is and air insulated metering module -01 No.b) Safe Plus type M-Air Insulated metering module 12 KV 630A, 20KA - 01 No.c) Bushing for connection external bus bar -01 Nod) 3 Voltage transformer of the ratio 11 KV/3/110V/3, 30VA, class 1.0 with HT fuses on the primary side and MCB on secondry side. e) RYB phase indications Additional equipments delivered seperately or mounted in respective panel.i) Manometer -01 Nosii) Operating handles 01 No(f) SLD of panel should be approved from GE before manufacture. 60 Providing platform for Transformer, Load breaker, APFC Panel and LT Main panel of size 8.0 x 4.0 x 1.25 Mtr high from GL including excavation in trenches 60cm, PCC 1:5:10 type D2 for foundation brick work in cm 1:6 PCC, 1:2:4 type B1 in copping plaster 10mm thick in cm 1:6 om brick /complete surface PCC 1:4:8 type B1 sub base 75mm thick as in floor PCC 1:2:4 type B1 100mm thick floor using extra cement returning filling and removal on surplus soil, chain link fencing 1.8m high made out of 4mm dia GI wire 150x100mm mesh MS work angle iron 50mmx50mmx6mm as fencing post in embeded in PCC work at 2 mtr interval each side as approved 1 No steel gate (3.5m clear) (fencing area cover 10M x 6M ) span as shown in drawing with locking arrangement made out of 15mm dia MS rod and 50x50x6mm angle iron frame . painting with 2 coat alu paint over a coat of red oxide primer and 3 coats of white washing on cement work including ISMB 100mm chanel 2 Nos for fixing transformer including making steps for Trasformer platform complete all as specified and directed by Engineer-in-charge. 61 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mfa working pressure, complete all as specified and as directed. 62 Double compressionbrass cable gland duly nickel plated for fixing armoured cable in panel of 3½ core 240 Sqmm to 300 Sqmm size complete all as specified and as directed. 63 Double compression brass cable gland duly nickel plated for fixing armoured cable in panel of 3½core 95 Sqmm to 120 Sqmm size complete all as specified and as directed. 64 Double compressionbrass cable gland duly nickel plated for fixing armoured cable in panel of 3½ core 50Sqmm to 70 Sqmm size complete all as specified and as directed. 65 Double compression brass cable gland duly nickel plated for fixing armoured cable in panel of 3½ core 25Sqmm to 35 Sqmm size complete all as specified and as directed. 66 Double compressionbrass cable gland duly nickel plated for fixing armoured cable in panel of 4 core 6 to 16 Sqmm size complete all as specified and directed. 67 Double compressionbrass cable gland duly nickel plated for fixing armoured cable in panel of 2 core 6 to 16 Sqmm size complete all as specified and as directed. 68 Cable jointing kit for 1.1 KV grade cable for end termination joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, aluminium conductor cable of size 25 to 50 Sqmm, Indoor/Outdoor type complete all as specified and directed. 69 All as per description of Srl item No. 66 here-in-before but for cable of size 70 to 95 Sqmm. 70 All as per description of Srl item No. 66 here-in-before but for cable of size 185to 240 Sqmm. 71 Synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified. (For TFR & Load Breaker etc). 72 Cable route indicator of size 200 mm x 200 mm x 5 mm thick GI plate with insertion three on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and grouting the same in ground with PCC as required incl writing/marking arrow for LT/HT cable incl necessery earth work all as specified and directed. 73 Bracket for fixing of street light fittings bent to shape, made out of 32/40 mm dia GI pipe medium grade not less than 1.2 mtr long fixed with two sets of MS clamps made out of flat iron of size 50mmx6 mm fabricated to shape and fixed with nuts bolts and washers & two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge 74 Junction box of thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65( weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands(IP-65) and/or grommets(IP-55). Size of enclosure: ( 250 x 180 x 110 ) mm With suitable connectors for /1Ph loop in loop out and branch out vibration proof connections and fixing on steel poles with 25x3mm thick 02 Nos of clamp with nuts and bolts and washers and proper thimbling complete all as specified and directed. 75 Supply, fabricating, installation, testing and commissioning feeder pillar box (KIOSK) out door type weather proof, dust vermine proof double door type CPRI approved LT panel made out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs), bus bar chamber enclosed complete, sheet fixed on angle iron frame/chanel of suitable size complete wiring alumnium bus bar chamber cable alley, cable glandes brass cromine plated of diffrent sizes suitable for incoming and out goingMCCBs panel paited with powder coated paint complete. (Note: SLD of panel should be approved from GE before manufacture.) 76 (a)Aluminium busbar of capacity 1200 Amps with eppoxy insulated supports 3 phase and neutral - 1 set 77 Incoming 78 (b) ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps - 01 Nos. 79 Outgoing 80 (c) MCCB 4 POLE 415 V 200- 250 A (36 KA) - 02 No (Outgoing) (P-3 & 4) 81 (d)MCCB 4 POLE 415 V 160 A (36 KA) - 02 No) (O/G) (P1 & APFC Panel) 82 (e)MCCB 4 POLE 415 V 100 A (36 KA) - 02 No) (For phase-II) (O/G) 83 (f)MCCB 4 POLE 415 V 63 A (25 KA) - 01 No) (O/G) for DG Panel 84 (g) MCB SPN, 32 Amp - 04 No. 85 (h) Digital type Ammeter including CTs and selector switch -1 No. 86 (j) Digital type Voltmeter and selector switches 0 - 500 V- 1 No 87 (k)Indicator - RYB- 1 Set, Internal Wiring of Panel, Civil Works & Labour Charges 88 Supply, installation, testing & commissioning of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 75 cms made out of 40x40x4 mm angle iron grouted on PCC platform upto 30 cms. PCC platform should be 60 cms above the Ground Level. Comprising the following:- .Note:- (i)The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii)Fabrication of feeder pillar box to be approved by CPRI.(iii)SLD of panel should be approved from GE before manufacture. 89 (a)Aluminium busbar of capacity 400 Amps with epproxy insulated supports 3 phase and neutral - 1 set 90 Incoming 91 (b) MCCB 250 A 4 Pole 35 KA - 01 No & fixed neutral link N with S/C & adj O/L releases phase indication indication lamlps with fuse 92 Outgoing feeders ; 93 c)MCCB 4 POLE 415 V 160 A (25 KA) - 01 No) (Outgoing) 94 d) MCB TPN, 40 Amp- 02 No. 95 e)MCB SPN, 32 Amp - 02 No. 96 f)Indicating lamp set LED type - 01 set. 97 g)Panel wiring with PVC insulated single core 2.5 sqmm copper cable. 98 h) PCC for fixing of LT Panel complete - 01 Job 99 All as per description of Srl item No- 74here-in-before but complete as per specification under:- 100 (a)Aluminium busbar of capacity 300 Amps with epproxy insulated supports 3 phase and neutral - 1 set 101 Incomer 102 (b) 160 A 4 Pole 25 KA MCCB- 01 No & fixed neutral link N with S/C & adj O/L releases phase indication indication lamlps with fuse 103 Outgoing feeders ; 104 (c)MCCB 4 POLE 415 V 63 A (25 KA) - 02 No) 105 (d)MCB TPN, 40 Amp - 02 No. 106 (e)MCB SPN, 32 Amp - 02 No. 107 (f) Volt meter & Amps mtr digital type 96 sqmm with CTs 400/5-3Nos and selector switch-01 set. 108 (g)Indicating lamp set LED type - 01 set. 109 (h)Panel wiring with PVC insulated single core 2.5 sqmm copper cable. 110 (j) PCC for fixing of LT Panel complete - 01 Job 111 All as per description of Srl item No- 74 here-in-before but complete as per specification under:- 112 Incomer 113 (b) 160 A 4 Pole 35 KA MCCB- 01 No & fixed neutral link N with S/C & adj O/L releases phase indication indication lamlps with fuse 114 Outgoing feeders ; 115 (c) MCCB 63 Amps TP 25 KA -04 Nos, with fixed neutral and S/C and O/L releases -05 Nos 116 (d) MCB 32 Amps 10 KA - 02 Nos for circuit control 117 (e)Volt mtr digital type 96 sqmm with selector switch -01 set. 118 (f) Amps mtr digital type 96 sqmm with CTs 400/5-3Nos and selector switch-01 set. 119 All as per description of Srl item No- 74 here-in-before but complete as per specification under:- 120 (a)Aluminium busbar of capacity 250 Amps with epproxy insulated supports 3 phase and neutral - 1 set 121 Incomer 122 (b) 63 A 4 Pole 16 KA MCCB- 01 No & fixed neutral link N with S/C & adj O/L releases phase indication indication lamlps with fuse 123 Outgoing feeders ; 124 (c) MCCB 32 Amps TP 25 KA -03 Nos, with fixed neutral and S/C and O/L releases -05 Nos 125 (d) MCB 32 Amps 10 KA - 02 Nos for circuit control 126 (e)Panel mounted Automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in panel mounted ,IP65 with the contactor,MCBs and copper circuit wiring (min.16sqmm) should enough to take: three-phase load of 12KW;contactor Rating 80Amps - 02 No 127 (f)Volt meter digital type 96 sqmm with selector switch -01 set. 128 (g) Amps meter digital type 96 sqmm with CTs 400/5-3Nos and selector switch-01 set. 129 (h)Indicating lamp set LED type - 01 set. 130 (j)Panel wiring with PVC insulated single core 2.5 sqmm copper cable. 131 (k) PCC for fixing of LT Panel complete - 01 Job 132 Disconnecting and Taking out unserviceable cables ofany size from ground, complete all as specified and as directed. 133 Supply, installation, testing & commissioning of totally enclosed feeder pillar outdoor type fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door typeincluding locking arrangement for each MCCBs, bus bar chamber enclosed complete suitable for operating on 415 Volt 50 Hz AC supply internally wired with copper conductor having legs 75 cms made out of 40x40x4 mm angle iron grouted on brick masonary platform upto 30 cms. Brick masonary platform should be 60 cms above the Ground Level. Comprising the following:- . 134 (a) 01 set of 200 Amps TPN aluminium bus bar of suitable length and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 16 KA at 415 volts. (b) Supply and fixing MCB TPN 40 Amp 10 KAMakes : Legrand /Schneider/Siemens -01 No as incoming.(c) Supply and fixing MCB TPN 32Amp 10 KA, Makes : Legrand /Schneider/Siemens -01 No as outgoing(d) MCB SP, 6 Amps 240 Volts AC 10KA - 04 Nos. Make :- Legrand/Schneider/Seimens(e) Automatic street light switch :- Make : Healer enterprises Model No SWADEEP 02EC5KW3P (f) Digital type amp meter 0-500Amp with CT’s & selector switch - 01 No. (g) LED Indicating lamp (RYB-one set) (h) Digital voltmeter 0-500 volts with selector switch 135 Supply and installations of silent Diesel Engine Generating set 415 Volts, 3 phase 4 wire, engine as per IS: 10001/10002 and alternator as per IS 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy with AMF control Panel as per CPCBIV+ norms and foundation etc of capacity25 KVA or its nearest higher size.A - DIESEL ENGINE:Liquid cooled, Electric start, four stroke, three cylinders, totally enclosed diesel engine, Terbocharged, developing 35.1 HPat 1500 RPM at NTP. The Engine is suitable for generating set application and fitted with the following standard accessories(i) Flywheel to suit coupling, (ii) Suitable coupling, (iii) Water cooling arrangement, (iv) Radiator with fan (v) Lube Oil Filter, (vi) Lube Oil Pump, (vii) Fuel Pump, (viii) Hoses to fuel tank, (ix) Air Cleaner assembly, (x) (Residential Heavy Duty Silencer (xi) Battery charger (xi) Fitted with requisite temperature and pressure gauges. 136 B - ALTERNATOR25 KVA TP CG/LS alternator at 1500 RPM, 0.8 lagging power factor, providing three Phase 415 Volts suitable for 50 Hz, H class insulated winding, Close-direct-coupled, Self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel base-frame. The alternator shall confirm to IS: 13364, IS: 4722, BS EN 60034-1, IEC: 34 and suitable for tropical condition. 137 C - CONTROL PANELFitted inside Canopy, fabricated out of CRCA Sheet of suitable thickness as per CPCB latest provision, cubical type, totally enclosed, Powder Coated, Control Panel incorporating the following:1. 1 No. Sedamac unit comprising: - Lube oil Pressure metering & Safety - High Water Temperature metering & Safety - Fuel Level Gauge in % metering & Safety - Voltage metering & Safety - Ampere metering & Safety - Frequency meter metering & Safety - Engine RPM metering & Safety & many more metering & Safeties - Power metering & Safety - Power factor metering 02. 1 Set MCB03. 1 Set of suitable Current Transformers04. 1 No. Toggle switch & Indicating lamps.05. Input & Output Terminals for incoming & outgoing E. AMF Panel- AMF Panel suitable for 25 KVA DG Set fixing of inside of canop for DG Set with fixing on suitable size of angle frame complete all as specified and directed by Engr In Charge. 138 F- ACCESSORIES01. BASE FRAME: Suitable base frame of sturdy design with necessary reinforcement and with in-built diesel tank.02. Fuel Tank:fuel tank of sheet metal, suitable enough for minimum 8 hours running of DG set complete with drain valve, air vent, inlet, outlet connections and mechanical gauge.03. BATTERY: - One No. battery of 12 volt charged of Amaron or Exide make with its leads. 139 EXTERNAL WATER SUPPLYSupplying, laying, Jointing and testing ductile iron pipe 150mm bore spigot & socket class K-7 as per IS-8329 with inside cement lined complete with push on rubber joints all as specified and directed by Engr-in-Charge.(Note:- During the laying of pipe line any damage to existing services, shall be made good/repaired by contractor as per existing system and rates are deemed to be included in quoted rate). 140 Supplying, Laying, Jointing and testing ductile iron pipe 100mm bore spigot & socket class K-7 as per IS-8329 with inside cement lined complete with push on rubber joints all as specified and directed by Engr-in-Charge.(Note:- During the laying of pipe line any damage to existing services, shall be made good/repaired by contractor as per existing system and rates are deemed to be included in quoted rate). 141 Construction of one brick thick (23 cm) masonary valve pit built in cement mortar 1:4 of size 150cm x 120cm x150cm (internal dimension) over 15cm thick PCC 1:3:6 type C-2 sub base extended alround 15cm beyond external edge of brick work including plastering 15mm thick in cement mortar 1:4 internally and flush pointing to brick wall surfaces externally as work proceeds complete with MS sheet cover 10 SWG with handle, angle iron frame 40mm x 40mm x 6mm (grouting with anchor fasteners length not less than 15cm - 04 Nos) including locking arrangement and painting, complete all as specified and directed by Engr-in-Charge.(Rate quoted by the tenderer shall deemed to be included the cost of excavation and earth work). 142 Description all as per Srl item No 83 here in before but of size 120cm x 90cm x 105cm (internal dimension). 143 Description all as per Srl item No 83 here in before but of size 90cm x 90cm x 90cm (internal dimension). 144 Pipeline route indicator of size 200 mm x 200 mm x 5 mm thick GI plate with insertion three on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and grouting the same in ground with PCC as required incl writing/marking arrow for water supply line incl necessery earth work,complete all as specified and as directed. 145 Disconnecting from pipe lines and Taking out from existing locations, sluice valves of the following sizes, complete all as specified and as directed:- 146 (a) 80mm bore 147 (b) 100mm bore 148 (c) 150 mm Bore 149 AIR CONDITIONING & DESERT COOLERAutomatic boost / bulk transformer for low & high voltage correction equipped with electronic transistorized relay suitable for correction on single phase50 c/s AC supply complete with voltmeter and designed for Input voltage 175Vto 250Vand output voltage 215V to 250V of capacity 5 KVA complete all as specified and as directed by Engineer-in-Charge. 150 Desert cooler with steel body having 450 mm fan size (heavy duty) with aluminium blade ISI marked electric driven (single phase) operating switch three step having nominal air flow capacity of 4000 CFM with wall thickness of sheet 1 mm and water tank and body pillar 1.5 mm thick including prewired electric control panel with immersed pump duly ISI marked pump and fan motor inlcuding provnof floot valve, complete all as specified and as directed by Engineer-in-Charge. 151 GEYSER & SOLAR WATER HEATING SYSTEM Stand made out of angle iron 50mm x 50mm x 6 mmand flat iron 50mm x 6 x mm,suitable forcold water tanks including painting the stand with 2 coat of synthetic enemel paint over a coat red oxide primer, complete all as specified and as directed by Engineer-in-Charge. 152 WATER COOLER & REFRIGERATIONAutomatic boost/bulk transformer for low & high voltage correction equipped with electronic transistorized relay suitable for correction on single phase 50 c/s A/C supply complete with voltmeter and designed for input voltage 175V to 250V and output voltage 215V to 250V of capacity 2.0 KVA complete all as specified and as directed by Engineer-in-Charge. 153 Supplying, installtion, testing and commissioning of refrigerator, electric driven (single phase), capacity more than 195 ltrs & upto to 210 Litres BEE 5 star rated,suitable for operation on single phase , 240 V, 50 Hz AC supply complete all as specified and as directed by Engineer-in-Charge. 154 Supply, installtion, testing and commissioning of refrigerator, electric driven (single phase), capacity more than 310 ltrs & upto to 360 Litres BEE 5 star rated,suitable for operation on single phase , 240 V, 50 Hz AC supply complete all as specified and as directed by Engineer-in-Charge. 155 ELECTRIC CHIMNEY FOR KITCHENSupply, installation, commissioning and testing Wall Mount Commercial type Electric Chimney for Kitchen including the following equipments complete in all respect 156 (a) Air Suction Capacity -1800CFM, , Voltage (V)-220-240, Power (W) - 220W, Phase-Single, Motor Power- 1 HP 157 (b) Material -SS, Mount Type- Wall Mounted, , Shape -Rectangular, duct complete. 158 (c) Material & Labour of Exhaust Hood, Shape -Rectangular complete. 159 Stainless Steel Hot Case Service Counter for cook house, Four Pan 1800mm AQUARIUS HTSC1002O7, size : 1800 x 730 x 915mm, power : 2.5kw, voltage : 220 volts. Complete all as specified and directed. 160 Stainless Steel Hot Case Service Counter for cook house, six Pan, 2300mm AQUARIUS HTSC1003O7,size : 2300 x 730 x 915mm, power : 3.0 kw, voltage : 220 volts. Complete all as specified and directed. 161 UPSSupply and fix UPS for 30 min back up single phase AC input voltage range 160 to 260 V and out put voltage 230 ± 1%,50 Hz of capacity 3 KVA,with noise level <50 db with overload and short circuit protection, efficiency>90% complete all as specified and directed. 162 UPS for 30 min back up single phase AC input voltage range 160 to 260 V and out put voltage 230 ± 1%, 50 Hz of capacity 5 KVA,with noise level <50 db with overload and short circuit protection, efficiency>90% complete all as specified and directed. 163 Schedule of Credit Works as listed in Schedule A Part-XIX has been attached in tender in PDF format amount of schedule i.e Rs. 25,21.119.80 shall be deducted from the total amount of BOQ to arive at the contract sum.
Contract Date: Mar 30, 2026 Contract Value : 18.24 Crore
Statutory Bodies & Commissions/Committees No of Bidders 8
Jammu And Kashmir View Result →
26.
Home Affairs #9618212 AOC
Purchase Of Departmental Store Articles. Purchase Of Miscellaneous Articles For Departmental Store. , Alluminium Utensil , Alluminium Ladder (8) , Allen Key Set , All-Outliquidator Machine , All-Out Liquidator , Alluminium Can (Big Size) , Alluminium Degchi (Raja) , Alluminium Frying Pan (Taj) , Alluminium Gamla (Taj) , Alluminium Handi (Raja) , Alluminium Karai (Raja) , Alluminium Nouka / Rice Tub (Raja) , Alluminium Plainsheet , Alluminium Saucepan (Raja) , Alluminiun Bucket (12) (Raja) , Alluminiun Bucket (14) (Raja) , Alluminiun Jug (Raja) , Alluminiun Tea Kettle (Raja) , Arial(500 Gm) , Arrowrot , Airwick Freshmatic Automatic Air Freshiner , Asbestos Sheet 2.5’X12’ (Everest) , Axe (Tata) , Bugle Cord , Bugle , Breath Analyzer , Blanket Woolen Single , Blanket Woolen Double , Black Tape 09 M Length , Betadine Lotion , Bike Helmet (Bestquality) Isi Mark , Bib Cock Pvc , Bernal , Bp Trumpet , Battery Nippo For Megaphone , Batali , Bass (Big) Drum , Baga Wrench (Pipe Wrench) , B^B Trombone (Tenor) , B^B Euphoniom , B^B Clarinet , Badminton Net (Falcon) , Brasso 250 Ml , Badminton Nylon Shuttle Cock ,Mavis -500(Yonex) , Badminton Racket (Yonex , Gr -303) , Badminton Racket (Yonex, Carbonex 6 Super) , Badminton Racket String , Bamboo Big Size , Bamboo Ladder 20 Fit. , Barbed Wire , Basin ( Hind Wear) , Basin External Pipe , Batterymedium (Eveready) , Battery Calling Bell (Eveready) , Battery Pencil(Eveready) , Battery Remote(Duracell) , Bed Sheet 5’X7’ (Bombay Dying) , Belchabig (Tata) , Bleaching Powder , Bib Cock2 -In -1 , Bib Cock (Brass) , Bib Cock (Steel) , Binocular (1.5 K.M.Range)- Nikon , Bitumin (Pitch) , Black Board Wooden (3’X4’) , Black Paper , Blade For Hacksaw , Blueliquid (Robin) , Blue (Robin) , Bone Dust , Bowl Big (Laopala) , Bowl Small(Laopala) , Brass Chain (Good Quality) , Brass Tub (For Flower) 12” , Brass Tub (For Flower) 14” , Brick , Brick , Broom Stick , Brown Cades (Ajanta) , Brown Target Paper (4’X4’) , Brush For Painting(3 Inch) , Brush For Painting(4 Inch) , Brush Holder , Cutter Machine Blade (Grinder) , Cutter Machine (Grinder) , China Nail 1.5 , China Nail 2 , China Shadle 20Mm , China Shadle 6Mm , Chisel 6 , Chitkani Alluminium 4, 6 , Chitkani Iron 4, 6 , Chopper (01 Ft) , Citronella 100 Ml , Clamp For Pvc Pipe , Cloth Clip , Commode (Hindware) , Coir Foot Mat 24 X 48 , Coir Foot Mat 12 X 36 , Carrum Board Stand G.I Pipe , Carbon For Drill Machine , Car Portable Fire Extinguisher , Car Perfume With Machine , Car Freshener , Car Duster , Camouflage Vest , Comfort 1 Letter , Cane Lathi 3 , Cane Busket , Carbolicacid 100 Ml , Casarol (Cello) 5 Ltrs , Curpet Jute , Carpet Nylon , Carrom Board 48 Good Quality , Carrom Board 52 Good Quality , Cement (Ambuja) -50 Kgs. Bag , Cement Piller 6 Ft. , Ceremonial Dress- (Hackle, Komor Bandh, Jhalar, Slave, Sparts, Belt, Medal, Shashe, Full Gloves) , Lance 8 Ft. , Ceremonial Pagri , Chaki & Belna , Chalk-Pencil , Clip , Clip Board , Coal –Tar , Coasters , Coir String , Colinspray -500 Ml , Compas , Connector Pipe , Corner Flag (Best Quality) , Corner Self 8”X 8” , Corrugate Sheet2.5’X10’(Jindal) , Corrugate Sheet2.5’X12’ (Jindal) , Cordless Calling Bell Remote Battery , Cordless Calling Bell (Havells) , Cordless Microphone Battery , Cow Dung , Cricket Bat Duse , Cricket Bat Tennis , Cricket Elbow Guard (Ss) , Cricket Helmet Duse (Ss) , Cricket Pads (Ss) , Cricket Thigh Guard (Ss) , Cricket Wicket , Curpet Nylon (Belgium) , Curtain Pipe 2/3 Dia , Curtain Best Quality , Curtain Medium Quality , Curtain With All Equipment , Face Mask (Sergical) , Face Mask (Cloth) , Drum Stick , Drum For Police Band 28 , Drum For Police Band 22 , Drill Bit Set , Iron , Drill Bit Set , Wooden , Drill Bit Set , Concrete , Door Skin 4 X 7 , Drum Belt 22 , Doctors Hygienic 500 Ml. (Floor Cleaner) , Door Handle Lock (Godrej) , Display Board (4 X 5) , Discuss Plate , Dinner Spoon Steel , Diathin 500 Gm. , Diamond Blade , Daw (Cutter) , D.A.P Fertilizer , Dendrite 100 Gm , Dettol Liquid -500 Ml , Dettol Liquid Hand Wash 200 Ml , Dettol Soap -75 Gm. , Dinner Set (Laopala) , Dinner Plate (Laopala), Full Plate , Dinner Plate (Laopala), Halfplate , Dinner Set Big Size(Laopala) , Discus -1 Kg (Nelco) , Discus -2 Kg (Nelco) , Door Chitkeni , Door Closer (Isi) , Door Handle , Door Kabja , Door Matcoir , Door Mat Iron Net , Door Mat Synthetic , Door Reparing With All Fitting , Drain Brush , Drain Brush With Lathi 6 , Drill Machine Set , Dustbin Plastic Big Size , Duster , Electric Welding Machine (Portable) , Electric Portable Spray Painting Machine , Electric Jhalai Rod (Steel) , Electric Jhalai Rod (Iron) , Electric Toster (Big Size) , Eb Alto Saxophone , Ear Plug , Earthenflower Tub (14) , Ezee 500 Ml , Dettol Hand Sanitizer 60 Ml , Dettol Hand Sanitizer 05 Letter Jar , Emari Paper , Empty Cement Bag , Empty Oil Dram 200 Ltrs. , Exhaust Fan (Havels) Medium Size , Exhaust Fan (Havels) Small Size , Flute Trumped (Bansi) For Band , Flower Tub (Cement) , Flower Stand With Flower ( Artificial) , First Aid Kit (Oxum Spray , Bandage 2 , Micropore Tape 1 , Band Aid 5 Pc , Volini Spray 15 Gm. ) , Fevicol/Ddl , Fire Extinguisher Bucket , Figuer 11 Target Paper .38 Revolver , Fire Extinguisher Bucket Stand (Iron) , Fire Extinguisher Cylender , First-Aid Box With All Equipments , Flag Rope (Cotton) , Flush Cock (Corsa) , Flask (Milton) Thermo Steel Carafe -1500 , Flask (Milton) Thermo Steel Carafe -1000 , Floor Tiels ( Best Quality) , Floor Tiles ( Vetrified) New Suppling And Fitting , Floor Wiper(Best Quality) , Floor Wipersponj (Best Quality) , Flower Vass (Best Quality) , Foot Ball (Cosco, Atlanta) Size-5 , Foot Ball (Cosco,Milano) Size-5 , Foot Ball Boot (Rahul) , Foot Ball Hose , Foot Ball Net Nylon , Freshmatic Automatic Spray (Air Wick) 250 Ml , Phooljharu , Funnel(Plastic) Big , Funnel(Plastic) Medium , Ground Sheet ( Satranji) 24 / 30 Ft , Ground Sheet ( Satranji) 18/24 Ft , Glucometer , Gloves Fire (Extinguisher Rubber) , Gloves For Sweeper , Gloves For Goal Keeper , Gas Oven Regulator , Gas Oven Hose Pipe , Gas Oven (18 X 18) , Gas Oven (12 X 12) , G.I. Bucket (Tata) 10 , G.I. Bucket (Tata) 12 , G.I. Bucket (Tata) 14 , G.I. Nouka / Rice Tub , G.I. Pipejoin Socket 2” , G.I. Pipe 1Dia (Tata) , G.I. Pipe 1.5Dia (Tata) , G.I. Pipe 2Dia (Tata) , G.I. Pipe 2.5 Dia(Tata) , G.I. Pipe 3 Dia(Tata) , G.I. Pipe Join Socket 1.5”Dia (Tata) , Gaita (Tata) , Gamaxin Power , Garbage Bags (Big Size) , Gardenumbrella - Standard Size , Garden Scissor , Glucose- 150 Gm , Good Knight Liquidator , Good Knight Liquidator Machine , Grass Brush , Grass Cutter Machine , Grey Paper , Ground Decoration Flag (Aney Collour) , Half Pant (Black) , Half Pant (White) , Hit Spray Red 400 Ml. , Hit Spray Black 400 Ml. , Hawkins Pressure Cooker 20 Ltr. , Hawkins Pressure Cooker 10 Ltr. , Hammer 02 Kg. , Hammer 200 Gm. , Hammer 100 Gm. , Hacksaw Blade (Double Head) Bipco , Hacksawblade(Isi) , Hacksaw Frame (Isi) , Hammer Iron 5 Kg , Hammer Wooden , Hand Shower (Jaquar) , Hand Towel (Bombay Dying) , Handel Wooden For Gita , Hanger (Best Quality) , Harpic- 500 Ml , Harpic Flashmatic , Hassian Cloth , Hasua –Medium , Hata (Steel) , Helmate Repairing With Painting , Hot - Pot Big Size (Cello) , Hot- Pot (Milton) 4 Bati , Iron Hook 4 , Iron Grill , Iron Brush Without Handle 6 , Inverter 850W (Microtech) , Induction Cooker (Prestige, 2000 Watt.) , Induction Cooker , Induction Cooker (Havels Insta Cook-Stx, 2000 Watt.) , Iron Angle (Tata) All Kinds , Iron Banti , Iron Brush , Iron Chanta , Iron Chimta , Iron Cot Paint , Iron Cot Repair With Paint , Iron Hamal-Dista (Medium) , Iron Hata (Medium) , Iron Karai (Medium) , Iron Khunti , Iron Khurpi , Iron Korai (Tata) , Iron Peg For Tent Complete , Iron Targetfor Practice Firing 4’X4’ With Stand (Rifle) , Iron Tawa , Immers Rod , Judo Mat , Javelin, Metal (Nelco) , Jet Pump 1 H.P With All Fitting Articles (Kriloskar/Compton Greaves) , Jhul Jharu , Jute , Kurl-On (Mattress) 6 X 7 , Kurl-On (Mattress) 5 X 7 , Kurl-On (Mattress) 3 X 5 , Kural , Khurpi , Khurni , Khanjani Big Size , Kabja With Screw 2/4/6 , Khunja (Earthen) , Large Screw Driver (Taparia) , Lal Saloo , Ladder Aluminium ( 8 Size) , Lawn Movers (Joy Bharat) , Lawn Tennisracket (Head, Model No-Metalix) , Lawn Tennis Ball (Head, Model-Champainship) , Lawn Tennis Net With Accessries (Spotiva Tennis Net) , Lawn Tennis Racket (Head, Model-No-Pct Ti Two) , Letterpancha-Z (Small) , Letter Pancha-Z (Big) , Lifebuoy Handwash (215 Ml.) , Loud Hailer (Ahuja) , Lime Dust (Mahabir) , Lime Stone(Mahabir) , Lyzol -500 Ml , Lyzol -1L , Lock With Key (Godrej)-6-Lever , Lock With Key (Godrej)-7-Lever , Lock With Key (Godrej)-8-Lever , Mosquito Net (Best Quality) Single Bed , Mosquito Net (Best Quality) Double Bed , Mixer Grinder Best Quality , 750W , Mirror With Back Side Ply (18 X 24 ) , Mirror With Back Side Ply (18 X 60 ) , Mike Complete Set Ahuja , Microphone Cord With Jack 8 Approx , Micro Oven Samsung 21 Ltr. , Mess Tin (Alluminium) , Macheti Anti Grass (500 Ml.) , Measurement Stand, Hight 8 Ft (Olimpia) , Measurement Tape 5 Ft , Measuring Tape (15 Mtrs) , Measuring Tape (30 Mtrs.) , Measuring Tape (50 Mtrs.) , Microwavable 1.7 Ltrs. Mixingbowl (Borosil) , Microwavable 2.5 Ltrs. Mixingbowl (Borosil) , Micro Oven Glass Bowl, Big (Borosil) , Micro Oven Glass Bowl, Medium (Borosil) , Micro Oven (Model-Samsung-73 Adb) , Mike Stand (Ahuja, Dgn) , Mirror (Best Queality) , Mixture Fertilizer , Mixture Glinder (Bajaj) , Mixture Glinder (Philips - Hl 1643/04, 600 Watt.) , Good Knight Coil , Mosquito Protect Net (Best Quelity) , Moulded Chair With Out Handel(Supreme) , Moulded Chair With Handel (Supreme) , Moulded Table (Supreme) , Muratic Acid 500 Ml. , Neosporin , National Flag (2X3) Khadi , National Flag (2X3) Silk , National Flag (4X6)Silk , National Flag (4X6) Khadi , National Flag Rope , Number Punch 0-9(Big) , Number Punch 0-9(Small) , Putting , Pvc Tarpauline 10 X 10 , Pvc Tarpauline 20 X 20 , Polythene Sheet 18 X 24 Best Quality , Polythene Sheet 18 X 18 Best Quality , Polythine Pipe 3/4 (Hindi) , Polymer Door (3 X 6.5) , Plus Taparia (10) , Plus Taparia (8) , Plastic Sheet (Best Quality) 7 X 3 , Plastic Mug (Cello) , Plastic Jhuri (Basket) , Plastic Bucket 20 Ltr (Cello) , Plastic Bucket 16 Ltr (Cello) , Plaster Paris , Plastic Table Cloth , Plank Lamp - Pati All Size , Plank Gamari All Size , Pillow Kurl-On , Palmet Curtain Bracket , Palmet Clip , Paint J&N All Colours , Pvc Floor Mat , Pumper , Plastic Sheet (Good Quality Black ) 8 X 10 , Over Head Shower With Ring , Odomos , Odonil , Olympic Torch (Best Quality) , Ors -100 Gm , Paint Black (Asian) , Paint Blue (Asian) , Paint Brown (Asian) , Paint Blue, Wheather Coat (Asian) , Paint Sky Blue (Asian) , Paint Green (Asian) , Paint Primer (Asian) , Paint Red (Asian) , Paint Silver Oxide/Aluminium (Asian) , Paint Terracotta, Wheather Coat (Berger) , Paint White (Asian) , Paint White ,Wheather Coat (Asian) , Paint Yellow (Asian) , Patching Paper , Piller Cock (Jaquar) , Pillow (Good Quality) , Pillow Cover (Bombay Dying) , Plastic Bucket (14) , Plastic Bucket (16) , Plastic Gamla (20 Ltrs.) , Plastic Jug , Plastic Mug Big Size , Plastic Mug Small Size , Polythin Pipe (Water Transfer) 100 , Potash , Pressure Cooker (Hawkins) -5 Ltrs. , Projector Screen , Pvc Ring , Pitambari 100 Gm. , Ruller For Colour , Rucksack , Rope Nylon Thick , Room Heater Blower (Bajaj) , Room Heater (Bajaj) Single Coil , Room Heater (Bajaj) Double Coil , Room Freshiner (Godrej) , Rifle Chain Iron , Revolver Figure Target Paper (Head) , Revolver Figure Target Paper (Body) , Reed Eb Alto Saxophone , Reed Bd Clarinet (Reco 3 1/2) , Rack (Wooden) A.K.-47 , Rack (Wooden) S.L.R , Rat Killer (Mortein) , Red Oxide , Revolver Full Target Paper 4’X4’ , Rice Light , Rogger 250 Ml. , Ropefor Tag Of War/ Monkey Rope , Rope Nylon 10 Mm , Rin Ala Liquid 500Ml , Round Cover , Swimming Costume , Sunmica Sheet , Sufala Fertilizer , Stop Watch Digital , Steel Curtain Bracket , Steel Cahin (4Mm X 4.56) , Steel Cahin (4Mm X 5) , Spoon With Spoon Stand , Small Umbrella , Skipping Rope , Sofa (Triple Seat) Steel , Sofa (Single Seat) Steel , Seris Paper For Iron & Wood , Sanitizer 100 Ml , Sand , Sand , Sandwich Meker (Morphy-Richards-Sm 3001,750W) , Saucepanwith Lid (Vinod, 1.5 Ltrs. ) , Saucepanwith Lid (Vinod, 3 Ltrs. ) , Saxophone Reed , Softic Halmet With Visor , Softic Halmet , Scotch Brite , Service Protector , Shaval , Shot Put -16 Pound (Nelco) , Shower (Jaquar) , Shuttel Cock (Mousumi, Association No -1) , Side Dram Synthetic Cover (Small Size) , Side Dram Synthetic Cover (Big Size) , Sil And Nora (Small) , Sil And Nora (Big) , Sink (Still) 16”/18”/20”/22” , Sink Cock , Spade (Tata), With Handle , Spade Handle , Spray Machine ( 16 Ltrs) , Sprinkler , Stainer 100 Ml , Steel Bati (Medium) , Steel Bati Plate (Medium) , Steel Dabu Hata , Steel Frok , Steel Gamla (Medium) , Steel Glass , Steel Handi (Medium) , Steel Jhanjra , Steel Jug , Steel Khunti , Steel Pan Spoon , Steel Panja Hata , Steel Pipe For Contingent Flag Bearer , Steel Plate , Steel Sabji Dani , Steel Dustbin (Mediun) , Steel Spoon , Steel Thala , Steel Water Drum (With Tap) 50 Ltr. , Stone Chips , Stop Watch (Racer) , Stove Kerosine (Tata) , Surf Excel Blue (500 Gm) , Surf Excel Bar 250 Gm , Sutli , Syntex Pvc Door , Track Suit Set Best Quality , Towe Big(Bombay Daying) , Tea Table Steel With Glass , Table Cloth Blue / Merun (6 X 4) , Table Cloth (Ordinary) , Table Glass 10 Mm (Best Quality) , Table Glass 12 Mm (Best Quality) , Table Glass 6 Mm (Best Quality) , Table Glass 8 Mm(Best Quality) , Target Paper 4 X 4 , Table Wooden 3’X4’ , Tarpelt (Tata) , Tarpin Oil , Tea Container (Thermoflax Steel Body) , Tea Spoon Steel , Tea Cup With Plate (Laopala) , Tea Set (Bone China) , Tea Table Wooden 3’X 2’ , Tennis Ball (Sixer) , Three Way Bib Cock , Tissue Paper , Tiffin Carier 3 Box (Milton) , Toaster (Bajaj Majesty Atx-9, Auto Pop Toaster, 800 W) , Toilet Brush (Wooden) , Towel, Big (Bombay Dying) , Towel Handle (Best Quality) , Towel Ring , Towel Rod 18” , Towel Rod 24” , Towel Stand , Towel White (Primium) , Tray (Best Quality) , Trey Melamine (Serve Well) , Tuli 0 To 5 Size , Urinal Complete Set (Best Quality) , Urinal Complete Set (Ordinary) , Ujala -100 Ml , Umbrella - Standard Size , Unit Flag (3 X 2 ) Silken , Unit Flag (6 X 4 ) Silken , Unit Flag With Logo & Embrodery Work (2’X3’) , Unit Flag With Logo & Embrodery Work (4’X6’) , Urea , Urinal Pan (Hindustan) , Use Me With Padle (Dustbin) Medium Size , Use Me Without Padle (Dustbin) Medium Size , Volini Spray , Vip Tray (Fibre) , Vinyl Board With Sticker , Velvet , Vest With Collour (Any Collour)-Full Sleeved , Vest With Collour (Any Collour)-Half Sleeved , Vim Liquid-250 Ml , Vimbar Soap -300 Gms. , Vinyl Flooring , Volley Ball (Cosco, Aclean ) , Volley Ball (Cosco, Super Volley) , Volley Ball (Nivia) , Volley Ball Net Nylone (Falcon) , Window Net Nylon Complete Setting , White Pt Vest (Best Quality) , White Canvas Shoes (Khadim / Elite) , White T-Shirt Half (Best Quality) , White T-Shirt Full (Best Quality) , Water Pump 1.5 Hp (Crompton) , Water Heater Connector Pipe , Water Drum Plastic With Lid 50 Ltrs , Water Drum Plastic With Lid 80 Ltrs , Water Drum Plastic With Lid 120 Ltrs , Water Container With Tap , Wall- Clock Ajanta , Wall Bit , Wall Hangar (Plastic) , Wall Hangar (Steel) , Wall Putty (20 Kgs. Bag) , Wall Tiles New Supplying And Fitting , Washing Brush (Cloth) , Water Drum (Pvc) 100 Ltrs. , Water Drum (G.I.) 100 Ltr. , Water Drum (G.I.) 200 Ltr. , Water Purifier 08 Letter (Kent) , Water Glass(Borosil) , Water Jhari- 5 Ltr. , Water Tank (1000 Ltrs)Sintex , Water Tank (500 Ltrs)Sintex , Water Tank (750 Ltrs) Sintex , Weight Machine (Digital) , Whitetable Cloth , White Board 3 X 4 , White Board Stand , White Cades (Ajanta) , White Cement- 50 Kg (Acc) , White Cloth (4’X5’) , White Cotton Bed Sheet (5’X7’) , White Phenyle (Cross) , White Shocks -(Anchor) , Window Repairing With All Fitings , Woodenhigh Bench1.5’X9’ (9 Ft) , Wooden Ladder 10 , Wooden Ladder 20 , Wooden Table (3’X4’) , Wooden Low Bench1.5’ X 9’(9 Ft) , Yoga Mat , Nonlit Board Fabricationalong With Flex Printing Without Structure , Nonlit Board Fabrication And Installation Along With Flex Printing With Iron Structure , Glow Sign Board Fabrication Along With Flex Printing Without Structure , Glow Sign Board Fabrication And Installation Along With Flex Printing With Iron Structure , Flex Printing For Glow Sign Board , Flex Printing For Nonlit Board , Flex Change (Without Flex Printing)Choke, Strarter & Wire , Flex Change (Without Flex Printing) , Sandwich Clip , 2 X 2 Angle , 1.5 X1.5 Angel , 1X 1 Angel , 2 X 2 Angle , 2.5 X 2.5 Angle , Ply Wood 2Mm , Ply Wood 6Mm , Ply Wood 8 Mm , Ply Wood 12 Mm , Ply Wood 4Mm , Brass Ball 1’ , Ball Valve , Ball Valve Handle , Elbow“R”1”X1/2” , G.I “ T”1’ X 1/2’ , G.I “R”Socket1’ X 3/4” , G.I “T” 1’ , G.I Elbow ½” , G.I Elbow 1’ , G.I Elbow¾” , G.I Nipple ½”X2” , G.I Nipple1”X2”X3”X4” , G.I Pipe ½” , G.I Thed 1’X6’ , G.I Union¾” , G.I Union1’ , Hole Tite , Hook¾ , Pvc 80 Cdh Pipe1” , Pvc Pipe 1/2 , Pvc Pipe 1 , Pvc Pipe 3/4 , Pvc Pipe 1.5 , Pvc Pipe 2 , Pvc Elbow 1/2 , Pvc Elbow 1 , Pvc Elbow 3/4 , Pvc Elbow 1.25 , Pvc Elbow 1.5 , Pvc Elbow 2 , Pvc Tee 1/2 , Pvc Tee 1 , Pvc Tee 3/4 , Pvc Tee 1.25 , Pvc Tee 2 , Pvc Union 1/2 , Pvc Union 1 , Pvc Union 3/4 , Pvc Union 1.25 , Pvc Union 2 , Pvc Claim , Gate Valve 25 Mm(Isi) , Gate Valve 10 Mm (Isi) , Foot Valve 25 Mm (Isi) , Foot Valve 10 Mm (Isi) , Jum Nut (Isi) , ‘J’Type Hook (Isi) , Nut Washer 1Inch , G.I. Socket 1 , G.I. Socket 1/2 , G.I. Socket 3/4 , G.I. Elbow 4 X 1/2 , G.I. Nipple 9 , G.I. Nipple 12 , G.I. Nipple 18 , G.I. Nipple 3/4 , G.I. T 3/4 X 1/2 , G.I. T 3/4 , G.I. T 1/2 , G.I. R Socket 1/2 X 3/4 , Anglow Stop Cock 1/2 , Solven , Tank Nipple , Bush , Welding Rod (Iron) , Welding Rod (Brass) , Fevicol Heatx , Fevicol Addisive , Door Stoper With Magnetic , Jersey For Football (Best Quality) , Jersey For Cricket (Best Quality) , Trophy For Winner (Best Quality) , Trophy For Runner (Best Quality) , Mementoes (Best Quality) , Trophy For Man Of The Match/Series (Best Quality) , Jersey(Cotton) With Printing , Jersey(Cotton) With Out Printing , Water Bottle , Ac Starter Set (Havels) , Bedswitch (Anchor) , Black Tape(Big Size) , Bulb 100 Watt (Philips) , Bulb 200 Watt (Philips) , Bulb 60 Watt (Philips) , Bulb Buttam Holder , Bulb Holder Angel (Anchor) , Bulb Holder Pendent (Anchor) , C.F. L. Lamp -11 Watt (Philips) , C.F. L. Lamp -5 Watt (Philips) , C.F. L. Lamp -8 Watt (Philips) , C.F. L. Lamp -14 Watt (Philips) , C.F. L. Lamp -18 Watt (Philips) , C.F. L. Lamp -23 Watt (Philips) , C.F.L. Lamp -32 Watt (Philips) , Led 09 Watt (Philips) , Led 12 Watt (Philips) , Led 15 Watt (Philips) , Led 45 Watt (Philips) , Cable4 Mm -2 Core ((Havels) , Cable6 Mm - 4 Core ((Havels) , Cashinggang Box -3 Way , Cashing Gang Box -2 Way , Cashing Gang Box -4 Way , Cashing Gang Box -5 Way , Cashing Gang Box -6 Way , Cashing Gang Box -8 Way , Casing1/2 , Casing3/4 , Ceiling Fan (Oriant)Size-48 , Ceiling Fan (Usha) Size-48 , Ceiling Rose (Anchor) , Ceilling Hanging Light , Change Over 63 Amp 4 Pole (Havels) , Change Over - 32 Amp (Anchor) , Cord Less Calling Bell (Havels) , Codenser For Fan , Calling Bell With Cord (Philips) , Calling Bell Without Cord (Philips) , Cover2 Model (Cabtree) , Cut Out -10 Amp (Anchor) , D.P Main Switch32 Amp (Anchor) , Dalda Pipe , Earthin Pipe , Earthin Rod , Earthin Wire , Elbowl (Pvc) , Elbowt (Pvc) , Electric Iron (Bajaj) , Emergency Light With All Equipments (Sigma) , Extension Board , Fan Hook , Flexible Wire (Star Line) , Fuse- 5 Amp (Anchor) , Fuse-63 Amp (Jj) , Full Thred Screw , G.Ishaddle 1/2 , G.I. Wire , Globlight Set (Best Quality) , Halogen Holder -1000 Watt(Philips) , Halogen Holder- 500 Watt(Philips) , Hellogen- 1000Watt Glass (Philips) , Hellogen- 1000 Wattfilament (Philips) , Hellogen 500 Wattfilament (Philips) , Hellogen- 500 Wattglass(Philips) , Hellogen Light Complete Set 500 Watt (Philips) , Indicator Lamp , Led Rice Light , Led Tube Light Complete Set 20 Watt(Havels) , Main Switch63 Amp (Havels) , Main Switchchange Over63 Amp (Havels) , Main Switch 32 Amp (Jj) , Main Switch 16 Amp (Jj) , Main Switch 63 Amp Tpn (Hpl) , Male - Female (Jj) , Mcb Box (Different Type) , Mcb Switch -10Amp (Havels) Singel Pole , Mcb Switch -16Amp (Havels) Singel Pole , Mcb Switch -32Amp (Havels) Singel Pole , Mcb Switch-63Amp (Havels) Singel Pole , Nail , Night Bulb (Philips) , P.V.C. Multigagewire -.75 Mm(Havels) , P.V.C. Multigagewire -1 Mm(Havels) , P.V.C. Multigagewire- 1.5 Mm(Havels) , P.V.C. Multigagewire -2.5 Mm (Havels) , P.V.C. Multigagewire- 4Mm(Havels) , P.V.C. Multigagewire -6Mm(Havels) , P.V.C. Multigagewire -8 Mm(Havels) , Pedestal Fan(Havels)Size-16 , Pedestal Fan(Usha)Size-16 , Pedestal Fan(Orient)Size-16 , Pliers (Taparia) , Pvc Gujji , Regulator For Fan (Usha) , Rise Light Led , Pixel Light Led , Pixel Led Smps , Pixel Led Controller , S. S Combined Set (Anchor) With Box , Screw (1) , Screw (1.5) , Screw (2) , Screw (3”/4) , Socket - 5 Pin (Anchor) , Socket 15 Amp (Cabtree) , Socket 3 Pin (Anchor) , Socket 5 Amp (Cabtree) , Socket Piano -15 Amp (Havels) , Socket Piano- 5 Amp (Havels) , Socket Type Regulator (Anchor) , Socket Type Regulator (Cabtree) , Stabiliser 250 Watt (Neutron) , Starter (Cabtree) , Steel Saddle , Strep Light Big Led With Adaptor , Strep Light Led With Adaptor , Switch 15 Amp (Anchor) , Switch 5 Amp (Anchor) , Switch 5 Amp (Cabtree) , Switch Type Regulator (Anchor) , Single Pole Mcb 32 Amp(Havels) , Top 2 Pin (Jj) , Top 3 Pin (Jj) , Top 15 Amp (Havels) , Top 5 Amp (Havels) , Top -5 Pin (Jj) , Tube Light Buttom , Tube Light Choke (Circuit) Havels , Tube Light Choke (Philips) , Tube Light Clamp , Tube Light Complete Set 28 Watt 4’(Havels) , Tube Light Complete Set 20 Watt (Havells) , Tube Light Lamp Yellow (Philips) 36 Watt. , Tube Light Holder , Tube Light Lamp- T-5 (Havels) , Tube Light Lamp (Havells) 36 Watt. , Tube Light Lamp 28 Watt(Havels) , Tube Light Starter (Philips) , Tube Light Complete Set 2 X 36 Fitting Box Type , Two Pin Plug (Jj) , Vapour Lampignator 250 W (Philips) , Vapour Lamp Bulb 400 Watt (Havels) , Vapour Lamp Choke 250 Watt (Philips) , Vapour Lamp Choke 400Watt (Havels) , Vapour Lamp Complete Set 250 Watt (Havels) , Vapour Lamp Complete Set 400 Watt (Havels) , Vapour Lamp Condencer 250 Watt(Philips) , Vapour Lamp Condencer 400 Watt(Havels) , Wall Catch Light Set (Havels) , Wire -2 Core (Starline) , Wodden Gujji , Wooden Biscuit (Sunmica)
Contract Date: Feb 20, 2026 Contract Value : 71.31 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
West Bengal View Result →
27.
Defence #9578617 AOC
Tender For Special Repair For Replacement Of Ber Equipments At Turf View Complex Under Ge (A) Kolkata - Disconnection of all old PVC fuel lines, fuel tanks from the existing 110 KVA BER DG Set atPower House and seggrigetting all these items and keeping aside complete all as specified and directed. 2 Taking out the BER DG Set 110 KVAfrom its existing position by unscrewing all the foundation bolts etc. and transporting the same (alongwith all of its accessories as dismantled under item No 1 above) by Escort Hydra/Crane to MES MT Yard of GE (A) Kolkata complete all as specified and directed. 3 Demolition of P.C.C in situ (platform of old DG Set) and removal of demolished concrete to a distance not exceeding 50 mtr from the starting point as shown by Engr-in-charge all and specified and directed. 4 M&L for brick work with sub class B bricks, straight or curve on plan exc. 6 m mean radius built in cement morter 1:4 to make good the disturbed wall as demolished under item No. 3 here-in-above. 5 Material and labour for providing plain cement concreate type B1 (1:2:4) using 20mm gradedstone aggregrate for making foundationwork complete all as specified and as directed. 6 M&L for rendering (plastering) 10mm thick on fair faces of brick work or concrete surfaces built in cement morter (1:6) complete all as specified and as directed. 7 Supply ,Installation, at site on foundation , commissioningof 125 -KVA, 415V, 50Hz, 3Ø silent new DG Set,comprising of Engine, alternator,Engine & alternatorto be fixed as per OEMs Design, Base frame, Fuel tank, Battery & leads, Auto Start & Stop panel (AMF), Residential Silencer, First fill of lube oil, AVM pad,CPCB-IV+ approved Engin & Acoustic Enclosure having following specifications :- 8 ENGINEMake: Cummins / CATTERPILLAR / VOLVOEngine Type :4 Stroke Diesel EngineRPM :1500Rated Output :161.6 BHP or Nearest Higher size as available.Duty : PRIMECooling:Liquid CooledCylinder : 4Aspiration:Turbo Charged after cooled.Type of Governer:Common rail electronic injection systemFuel Tank Capacity :Minimum capacity 275 Liters Diesel Tank , with Inlet & outlet arrangement with Drain Plug and Air vents.Engine instrument Panel : Consisting of starting switch with Key, Lube OilIndicator, water temperature Indicator, RPM indicator and hour meter.Exhaust Silencer: HOSPITAL GRADE TYPE and complying with CPCB-IV+Norms.Starting system: 12V, DC power srtarting system complete with starter motor, charging alternator with rectifier and cutout as per manufacturer standard and to be compaitable with AMF Panel. 9 LOAD :Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528Battery:12 V X 1, 95AH Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning 10 ALTERNATORMake:Stamford/Kirloskar electric co/ Leroy SomerRating: 415 V., 3Ph. 50 Hz., 125 KVA, 100KW, 1500 rpmType : Brushless, self excited and self regulated through an AVR.Insulation:Class HighProtection : Screen-protected drip proof with Min.IP-23 degree of protectionRPM: 1500Rated Current :174 AVoltage Regulation (max) : ±1%Winding connection: Star with NeutralTotal Distortion factor:Less than 3%Power Factor : 0.8 pf (lag)Total Harmonic distortion in output waveform : < 5% 11 ACOUSTICENCLOSURE The DG set should have integrated acoustic enclosure at the manufacturing state itself with 11 tank process.High quality acoustict enclosure must be certified as per CPCB-IV+ norms and silencer should be inside the enclosure. Maintainance Period : Engine oil change period shoud be 750 hrs or 1 year . 12 BASE FRAMECommon iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook. 13 Supply and laying for under ground heavy dutyXLPE insulated, armouredaluminium conductor cable1100 volts grade, cross-sectional area 120 sq. mm 3.5 corein trenchches / through pipe or bare in road crossing / plingth/ drain/ duct/ floor along pole/ wall /ceillings etccomplete all as specified and directed. Note:- Earth work, bricks protection sand cuisioning shall be measured and paid seperately. 14 Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for foundationor for laying of cable , fixing of poleetc and getting out in soft/loose soil, old serviceable bricks etc complete all as specified and as directed. 15 Returning, filling in trenches including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. 16 Removing excavated soil to a distance not exceeding 50 metre anddepositing where directed at a level , not exceeding 1.5 metre above the starting point complete all as specified and as directed. 17 Materials and labour for sand filling 23 cm thick above thecable with approved quality coarse sand for sand cushioning of under ground cableincludingspreading and punning down to desired thickness of 18 cm complete all as specified and as directed. 18 Supply and laying for burnt brick sub class B locally available best quality laid in trenches for protections of under ground cable complete all as specified and as directed. 19 Materials and labour forplain cement concreate (1:3:6) type C2 (using 40 mm gradeed stone aggregrate) as in foundations filling, coping for poleand mass concreate filling of trench across the road etc. complete all as specified and as directed. 20 Cutting existing metal/bituminus road/PCC walk way/any type of tile worksn.exc 0.45m width and n.exc 0.90 m in depth including all connected earth work and making good disturbed surfaces matching with the existing specification and finish including disposal of surplus material to a distance n.exc 50m complete all as specified and as directed. 21 M&L for Earthing complete with copper earth plate (60cm x 60cm x 3.15 mm) thick, buried directly in ground (earth pit not less than 3.25 mtrs. deep below ground level) with top edge of the plate not less than 2.5 mtrs. below normal ground level, connected to (32 X 6) mm copper strip as earthing lead by means of bolts nut check nuts and washers of galvanised iron or steel necessary earth work, drilling hole, RCC cover with handle, GI tubing medium grade 20 mm dia for watering, funnel wire mess GI bolts with washer of suitable size all as shown in electrical plate No 3 connected to earth test point all as specified or indicated incl. testing on completeion. (Note : Fresh soil will be used for filling the dug as required to achieve the desired resistance from out side, copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection necessary cost of repair to plinth protection and brazing and welding deemed to be included in the item copper strip beyond 7.5 RM will be connected through double nut bolt and brazing of joints). 22 Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground, earth pit not less than 2.25 mtrs deep below ground level, with top edge of the plate at a depth of not less than 1.5 mtrs below ground level connected to galvanized earth strip 32x6mm diaincluding GI pipe 40 mm bore (Medium grade) as earth leadprotection and necessary earth work, RCC cover with handle, GI tubing medium grade 20 mm dia for watering, funnel wire mess GI bolts with washer of suitable size all as shown in electrical plate No.3 of MES SSR Part-I and connecting to earthing test point including necessary excavation and earth work in any type of soil, returning, filling in and disposal of surplus soil to a distance exceeding 50mtrs, PCC (1:3:6) type C1 (using 20mm graded stone aggregate) earth pit, 40mm thick RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) cover with suitable reinforcement, watering arrangement, funnel etc complete all as specified and directed. 23 Supply and fixing for single aluminium strip of size (25x3.15) mm in proper position with saddles and fixing screws for earthing connection to equipments and making good the disturbed surface complete all as specified and as directed. 24 Supply and fix Copper strip (25 x 4.0)mm in proper position with saddles and fixing screws for earthing connection to equipments and making good the disturbed surface complete all as specified and as directed. 25 S&F GI pipe light grade 80 mm Tubes with all fitting andfixed complete to walls and ceilings or laid in floors complete all as specified and as directed 26 S&F XLPE Armoured copper cable 2.5 Sqmm 7 core 1100 Volt grade laid in existing trench/wall by excavation complete all as specified and directed. 27 Taking down unsv ceiling fan of any type and any sweep from existing after disconnection of all electrical connections , dismantling of fan blades and deposited to MES store yard of AGE E/M-II at Turf View Alipore complete all as specified and directed. 28 Supply and fixing Five star rated with brushless direct current motor (BLDC) ceiling fans 1200 mm sweep complete with 3 Nos blades, down rods, electronic regulator and accessories, 230 V AC,min air delivery 350-370 rpm with service value 7.50 BEE having power consumption between 26-30 watt completeall as specified and directed. 29 Supply and fixing Exhaust fan 250 mm sweep, with polycorbonateblades 230 volts 50 Hz single phase including louvres & shutters nuts and bolts completeincluding modification of existing hole(if required) completeall as specified and directed.Note : Old dismantled unsv exhaust fanswill be deposited to MES store of AGE E/M-II at turf view for further disposal under departmental arrangements.
Contract Date: Feb 12, 2026 Contract Value : 36.17 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
28.
Defence #9578058 AOC
COMPREHENSIVE REPAIRS / MAINT OF 33/11 KV MRS AT SUNDERABANI UNDER GE(N) AKHNOOR AND COMPREHENSIVE REPAIR/MAINT OF HT CABLE, BUS BARS, EARTHINGS, ACSR CONDUCTOR, CLEANING OF BUSHES &BRANCHES AT BARAKH AND SUNDERBANI AREA UNDER GE (N) AKHNOOR; 1 Supply and fixing in replacement of GOD 33 KV rotating , horizontal type,double break triple pole outdoor gang operated centrepost rotating manually operated isolator switch 400 Amp having 12.5 KA (RMS) for 3 sec short circuit rating with 9 nos 33 kv capacity and pin type post insulator with 320 mm cleavage distance and pedestal of height of 200mm to maintain line earth clearage of 370mm mechanically inter locked triple pole earthing with having independent manually operated handle complete with all supporting stucture of suitable channel, nuts & bolts etc complete all as specified and directed. 2 M&L for scrapping laid out aggregate of any size and removing from site and cleaning of dirt and vegetation from site and relaying of the same in switchyards complete all as specified and directed. 3 M&L for painting of HT 33 KV HT grid steel structure including all MS channel isolators, CTs, PTs and MOCBs, VCBs, bus bar and other steel structure with synthetic enamelled aluminium paint on structure abd other colour code for equipment after proper surface preparation complete all as specified and directed. 4 M&L for Jumpers works in PTs, CTs, MOCBs, isolator, DO fuse by using parallel grove clamp, Tee clamp Tee clamps other connectors required by using ACSR conductor any sizess (Dog/Mouse)including dismantling old conductor and clamp complete all as specified and directed. 5 M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to DB/Panel by using GI strip of 32x6 mm sleeved using red colour PVC sleeving as earthing lead soldering/rivetted to earth plate at one end and connected to existing structureby means of nut, bolts etc complete with PCC pit (1:3:6) type PCC cover with handle, funnel with watering pipe wire mess GI protection pipe for earthing lead complete all as specified and directed. 6 Supply and fixing Danger notice plate of 1.6 mm thick MS sheet,vitreous enamelled white with letters, figures and conventional skull and bones with MS clamp, bolts and nuts of approved size for HT, 25x20 cm,(33KV/ 11 KV mark complete all as specified and directed. 7 M&L for steel tubular swaged type poles 11 metrs long,pole weight approximately 227 kgs, pole should be in one piece only and smooth finishing and smooth finishing of pole,ISI marked complete with all accessories such as cast iron base plate, finial taper plug,bolts, nuts, screws,washers and drilling of holes for continious GI earth wire as specifiedtype 410 SP-55 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface complete all as specified and directed. Make as approved by GE. 8 M&L for steel tubular swaged type poles 12 metrs long,pole weight approximately 292 kgs, pole should be in one piece only and smooth finishing and smooth finishing of pole,ISI marked complete with all accessories such as cast iron base plate, finial taper plug,bolts, nuts, screws,washers and drilling of holes for continious GI earth wire as specifiedtype 410 SP-64 including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface complete all as specified and directed. Make as approved by GE. 9 Labour for complete Overhauling and Servicing of 33 KV out door type VCB including disassembly of operating mechanism parts,spring charging motor andmechanism well cleaning with petrol and CRC-226, replacing unserviceable spare parts/accessories i.e incoming jumper connection,bushing holding moving and fixed contact assembly,GO rod,inter connection assembly,spring charge mechanism and oiling and greasing of moving contacts and fixing contact parts and checkingof pole insulators,checking of vacuum interrupters, incoming and outgoing terminals,flexible connections,suporting insulators,operating rod, tie barcommon operating shift,operating corn, locking cam ,making spring,breaking spring,loading spring,and main linkwell cleaning mechanism linkages drive insulators and fiber reinforced plastic frame around the vacuum interrupters including routine and periodical test, complete all as specified and directed.(Note : Supply only spares will be measured and paidseparately) 10 Supply only spring charging motor with gear and connector for VCB of voltage 30 Volts DC or as required at site compatible with OD VCB 11 Supply only Closing and tripping coil for SF6/VCBas per site requirements. 12 Supply only Auxillary switch for 33/11VCB as per site requirements. 13 Supply only Limitswitch for33 KV VCB as per site requirements. 14 Supply only Hooter suitable for 33/11 KV breaker as per site requirements. 15 Supply only T&C switch with locking arrangement.suitable for 33 KV breaker 16 Supply only Remote selector switch incl control wiring suitable for 33 KV breaker 17 Supply only LED Indicating lamps of desired colour dual input type. 18 Supply only Vaccum Interrupting unit (bottle type) suitable forSF 6 breaker 19 Supply only IDMT,IDMTL relays suitable for 33 kv breaker and calibration through primary and secondary testing and connected accessories for functional requirement checking of electrical wiring system and testing complete all as specified and directed. 20 Supply only Control Cable 8 core armoured control2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unitcomplete all as specified and directed. 21 Supply only Control cable 4 core armoured control cable 2.5 sqmm copper for interconnecting from remote panel to VCB outdooor unitcomplete all as specified and directed. 22 M&L forgalvanised cross arms,bracings,supports,clamps, angles,hellowbars square/round,flat irons etc and back plates fabricated in structural steel sections including nuts, bolts,washers, welding, bending, fabrication, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coatand anti corrosive silver paint one undre coat and one finishing coatand including removing old unserviceable item complete all as specified and directed 23 Supply and fix and in repair 11 KV out door type Air Breakgang operated device of rating400 Amps, triple pole, vertical type,mechanically operated, mounted onHT insulators 15 Nos, incl drop out fuse assy and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium gradewith operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supplycand testing complete all as specified and directed. 24 Supply and fix and in repair 11 KV out door type Air Breakgang operated device of rating200 Amps, triple pole, vertical type,mechanically operated, mounted on HT insulators 15 Nos, incl drop out fuse assy and steel channel frame with operating machanism worked from ground level with GI tubing 25 mm dia medium gradewith operating handle and locking arrangement including seven lever navtal lock and providing ACSR conductor jumpers duly crimped with lugs, connecting to existing 11 KV supplycand testing complete all as specified and directed. 25 M & Lfor PCC 1:3:6 type C-1 (using 20 mm graded aggregate). For foundation, filling,mass concrete, coping etc incl finishing of external surfaces without applying extra cement incl dismantaling old PCCcomplete all as specified and directed. 26 M & Lfor PCC 1:4:8 type D-2 (using 40 mm graded aggregate). For foundation, filling,mass concrete etc incl dismantling old PCC complete all as specified and directed. 27 Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, HT electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 95 Sq mm, 3 core complete and taking down of UNSV HT cable from existing site complete all as specified and directed. 28 Supply and laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, HT electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 120 Sq mm, 3 core. complete and taking down of UNSV HT cable from existing site complete all as specified and directed. 29 M & L for excavation in trenches soft loose soil ,for laying under ground cable, errection of poles and stays in any type of soilnot exc 1.5 Mtr wide and not exc. 1.5 m in depth for foundation and getting out complete all as specified and directed. 30 M & L for excavation in trenches,for laying under ground cable,pipe lines, errection of poles and stays in any type of soilnot exc 3.0 Mtr wide and not exc. 3.0 m in depth for foundation and getting out complete all as specified and directed. 31 M & L for returning filling in including spreading, levelling, watering and ramming in layers not exceeding 25 cm thick with earth obtained from excavationcomplete all as specified and directed. 32 M & L for removal of surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting pointcomplete all as specified and directed. 33 M & L for unwashed sand cushioning below and around cable in trenches with river sandcomplete all as specified and directed. 34 Supplying and laying un-reinforced precast concrete cable cover HV, Type 1, flat, size 300mmx l80mm x 40mmcomplete all as specified and directed. 35 S & F 80mm bores of tubes light grade galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cablecomplete all as specified and directed. 36 Supply and fixing cable jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and directed. 37 Supply and fixing cable jointing kit for 11 KV grade cable for in door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 120 sqmm to 185 sqmm complete all as specified and directed. 38 Supply and fixing cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and directed. 39 Supply and fixing cable jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 120 sqmm to 185 sqmm complete all as specified and directed. 40 Supply and fixing cable straight through jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 50 sqmm to 95 sqmm complete all as specified and directed. 41 Supply and fixing cable straight through jointing kit for 11 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but 120 sqmm to 185 sqmm complete all as specified and directed. 42 Supply insatallation, testing and commissioing of maintenance free cemical earthing based on 300mm long GI earthing Electrode (Met -Chem) 80mm outer dia and inner rod with 10mm thickness 3000 mm long duly filled with ITPC-EECP15fixed with nuts an bolts incl excavation/ earth work in any strata & PCC chamber with CI Frame and cover (Earth pit not less than 2.25 mtrs below ground level). The electrode is surrounded by chemical (ITPC-EECP15) a mixture of sulphate, silica, Iron Oxide etc, magnesium oxide, sodium oxide, zinc oxide etc. Each Earth electrode should have resistance <2 Ohm by using earth electrode is used as per the site requirements. Chemicals compound powder to be provided minimum 50Kg per site. The inspection joint provide for earthing reference incl the man hole cover with locking facility be provided. 43 S&FCopper strip of size 20 x 3 mm as in earth continiuty conductor fixed to wall on batten or recess or cases or buried in ground or any other situation for loop earthing as required at site complete all as specified and directed. 44 Disconnecting electrical connections from HT 33/11 KV, capacity 1.25 MVA transformer of any descriptions by opening of earth & control connections of any type, sealing of oil leakage, replacement of unserviceable parts and cleaning the transformer, including making all HT connections, control cable connection, earth connection etc including testing the transformer after necessary repairs complete all as specified and directed.Note: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items. 45 Supply and fixing in replacement of primary coil of HT 33/11 KV,capacity 1.25 MVA transformer of any specification, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications complete all as specified and directed.Note: Primary coil shall have same number of turns of winding wire and with matching to manufacturer design. 46 Supply and fixing in replacement of secondary coil of 33/11KV, capacity 1.25MVAtransformer of any capacity, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications,complete all as specified and directed.Note: Secondary coil shall have same number of turns of winding wire and with matching to manufacturer design. 47 Replacement of old unserviceable/ damaged 33 KV HT bushing assembly with new HT bushing assembly with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, any capacity complete all as specified and directed. 48 Replacement of old unserviceable/ damaged 11 KV HT bushing assembly with new HT bushing assembly with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, of any capacity,complete all as specified and directed. 49 Dehydration and filtration of 33 /11 KV transformer oil after draining out oil from transformer by the dehydration machine at site or nearby transformer workshop to achieve di-electric strength 50 KV at 4mm gap,complete all as specified and directed.Note: (i) Cost of transportation of dehydration machine and other required materials and tools, plants shall be deemed to be included in the quoted rates.(ii) Test certificate of di-electric strength from auth Lab shall be produce before and after dehydradation and filtration process for each transformer. 50 M&L for Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel suitable for 33/11 KV transformer including nuts, bolts and washerscomplete all as specified and directed. 51 Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel capacity 500 gm suitable for 11/.440 KV transformer including nuts, bolts and washerscomplete all as specified and directed. 52 Supply only fresh transformer oil to top-up and filling in the existing transformer, di-electric strength not less than 45 KV, meeting Bureau of Indian Standards: IS 335-1993 (Reaffirmed-2005) specification,examined in a 100mm thick layer at 270°C, clear, transparent and free from all type of suspended matter or sediment,complete all as specified and directed. 53 M&L Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, 33000 voltscomplete all as specified and directed. 54 M&L Lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, 11000 volts complete all as specified and directed. 55 S&F Disc type insulator porcelain, vitrous 145 mm high and 255 mm dia ball and socket type, (white, brown or green) complete single disc assembly for ACSR conductor having working pressure 11000 volts gradecomplete all as specified and directed. 56 S&F Pin type, porcelain, vitreous, white, brown or green insulator includingone galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,150mm height, 150mm dia for 11000 volts grade complete all as specified and directed. 57 S&F Pin type, porcelain, vitreous, white, brown or green insulator includingone galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 33000 volts grade complete all as specified and directed. 58 M & L for Servicing and complete overhauling of VCB 11 KV Indoor type 630 Amps capacityincluding disassembly of operating mechanism parts, well cleaning with petrol & CRC-226, replacing of moving parts, re-assembly, fine setting of mechanism, replacement of unserviceable parts and re-assembly of parts including well cleaning the complete panel board main bus bar, de-carbonizing all joints, bus bar, CTs’ PTs spouts, metal parts and making VCB perfect operation in manual and electric mode including all routine and preventive maintenancecomplete all as specified and directed. 59 Supply and fixing by stringing stretching and strengthening on insulators ACSR conductor of desired size including aluminium binding wire of suitable cross sectional areaincluding joints sleeve for jointing conductors of equal or unequal size and for jumpers connections including treatment of connector and ACSR conductor joints/jumpers with conducting jelly, and taking down of UNSV conductors complete all as specified and directed. 60 Material and labour for tree branches/vegitation cutting around the HT lines and installations from line conductor to tree distance up to 4 mtrs and cutted wood pieces/vegitation materials disposal upto distance not exc 100 mtr at defence landlocation whereas directedand including providing safety eqpts & cutting tools,ladders etc will be own arrangement by the contractor and complete all as specified and directed.Note:- (1) Safetymeasures will be fully responsibleby tenderer (2) During tree /branches/vegitation cutting any damages on OH lines/installation should be reuniform responsible fully by the tenderer with out any extracost.(3) Approximately distance coveredboth side for the HT lines/installatons not exc 100 mtrmeasuredas a one span only 61 Material and labour for paintng of HT pole of any type/size/length and removing from existing pole painting by using wire brush and using with emary paper and cleaning with chemical agents after cleaning of steel tubular pole and GI brackets and cross arms in two coats of red oxide primer and two coats of silver oil painting upto smooth finishiningand paintingto satisfactorly by engr-in-charge and painting work carryout at any height and including marking of pole numers as directed and safety eqpts & tools will be own arrangement and complete all as specified and directed. Note:- Cost of painting materialis deemedto be included in quoted rate only. 62 Supply and fixing in replacement galvanized iron strip of size 32x 6 mm to be fixed on wallor to belaid in ground including taking down from any position and any placescomplete all as specified and directed. 63 Material and labour for fault finding on 11 KV HT cables in trenches of any size and any length with fault detective(fault finding) machine by thumbing method andinjection suitable high voltageproper fault finding equipment and all as testing device instructions and including necessary excavation, returning filling,removing surplus soil,sand, existing bricksetc where find the cable faultycomplete all as specified and directed. 64 Material and labour for scraping of old paint of 33/11KV yard substation (02 Nos bay) steel structure posts by using emery/iron brush and painting with two coats of aluminium to complete 33/11KV substation including entire steel structure upto height of 10 mtr incl aluminium painting of XPM jalli around transformer,spray painting to CT/PT unitscomplete all as specified and directed.Note:- Contractor has to take complete shut down and contractor shall not be provided working periods more than 02 Hrs/day 65 M & L for Scraping of old paint of HT pole 11/12 mtr height without removing accessories and preparationof surfaces for repainting.Repainting the poles with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr above ground level height using synthetic enamel paint .Repainting the remaining Iron parts i.e. cross arms, supporting angles, clamps, GI bkt etc and steel pole above 1.5 mtr height by applying one coat of aluminium paintor PCC pole with snowcem of approved color all as required at site or directed. 66 S & F 100 mm bores of tubes light grade galvanised with all fittings and fixed complete with electric pole, laid in trenches for passing of XLPE cablecomplete all as specified and directed. 67 Supply, fabricating, installation, testing , commissioning and electrically connecting HT bus bar feeder pillar box for 95 Sq.mm Cable and Panel of size 100cm x 110cm x 65 cm,11KV ,factory made , machine pressed , dust and vermin proof ,out door type made with CRCA sheet 3.15 mm thick , HT Feeder Pillar internally and externallyshall bepainted with expoxy powder coating RED paint with 7 tank process for treatment of degreasing, pickling & two coats primer, IP65, before being given the stove epoxy finish. , both side opening in two halves with rubber beading , including Aluminium bus bar of 250 Amp (Each Strip Size 50 x 6mm x Length 800 ) capacity, 4 strip mounted on HT porcelain insulators, HT Danger Plate Provided on Both Side,bus bar chamber and shall be provided with inspection covers , Cubical switch shall have the independent opening panel and shall be mounted on angle iron frame and legs made from angle ironof size 50mm x 50mm x 6mm frame including lifting arrangement and legs duly spray paintedwith two coats of synthetic enamelpaint over a coat of redoxide primer , embeding and grouting in PCC (1:2:4) type B1using 20 mm graded crushed stone aggregate in foundationincluding necessay earth work, including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 vot grade comprising, Cable enter with Cable Glands and following accessories including testingcomplete all as specified and directed. 68 M & L for replacement shackle type porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 150mm height, 150mm dia for 11000 volts gradecomplete all as specified and directed. 69 Supply and fixed cable jointing kit for 33 KV grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium condcutor cable of size but95 sqmmcomplete all as specified and directed. 70 Note:- Deduction for Schedule of credit (Sch A Part-II) to be made of ₹201920.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents.
Contract Date: Feb 10, 2026 Contract Value : 28.80 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 4
Jammu And Kashmir View Result →
29.
Defence #9578055 AOC
Tender For Special Repair To Building No P/139 And P/140 At Batra Enclave Under Ge Panagarh; 1 SCH A PART-I : B/R PORTION 2 M&L Rendering 10 mm thick cement plaster in Cement Mortar 1:6 onfair faces of brick/concrete work surfaces finished even and smooth (without using extra lime or cement) including taking down old/ unserviceable cement plaster, complete all as specified and directed. 3 M&LRendering 15 mm thick cement plaster in Cement Mortar 1:4 onother than fair faces of brick/concrete surfaces finished and smooth without useing extra cement and using water proofing compound as per manufacturers instruction by weight of cement content including taking down old/ unserviceable cement plaster, complete all as specified and directed.[Note : WPC will measuered and paid separatly under relevant item of schedule.] 4 M&L Rendering 5 mm thick on fair faces of ceiling / chajja concrete surfaces in cement mortar 1:3finished even and smooth (without using extra lime or cement) including taking down old/ unserviceable cement plaster, complete all as specified and directed. 5 Supply only liquid water proofing compound, complete all as specified and directed. 6 M&L TMT mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with theincluding mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to, complete all as specified and directed. 7 M&L TMT mild steel bars 6mm to 8mm dia ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to, complete all as specified and directed. 8 M&L Reinforced Cement Concrete M-25 grade (nominal mix) using 20 mm graded stone aggregate as in slab supported on wall, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc., including demolition of old/unserviceable reinforced cement concrete, complete all as specified and directed. 9 M&L Reinforced Cement Concrete M-25 grade (using 20mm graded stone aggregate) for chajjas and the like including demolition of old/unserviceable reinforced cement concrete, complete all as specified and directed. 10 Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and semilar works not exceeding 200mm thick (horizontal or sloping), surface of concrete flat for rough finished surface of concrete, complete all as specified and directed. 11 Use and waste of Formwork to chullah hoods, chajjas, troughs and similar items including edges etc surface of concrete flat for rough finished surface of concrete, complete all as specified and directed. 12 M&L Welding MS wire mess weighing not less than 1 kg/sqm and primed withcorrosion resistan, two component, zinc rich epoxy primer, fixing to the prepared concrete surface through proper fixing arrangements and applying 40 mm thick avg cement mortar with guniting and shot gun at a pressure not less than 4 kg/sqm in ratio 1:2 mixed with liquid water proofing compound chemical not less than 5% by weight of cement including tapping of new reinforcement to the rusted portion all as manufactures instructions and carried out the work as per procedure, complete all as specified and directed. 13 M&L 75 mm thick Plain Cement Concrete 1:3:6 type C2 (using 40mm graded stone aggregate) fininshed as in plinth protection surfaces even and smooth without using extra cement including demolition of old unserviceable plain cement concrete, complete all as specified and directed. 14 M&L providing plain cement concrete type B0 1:2:4 (using 12.5mm graded stone aggregate) as in coping to chajja tops and all other similar works, including demolition of old unserviceble plain cement concrete, complete all as specified and directed. 15 M&L taking down old unserviceable sunken floor concrete & WCs and applying (a) providing and laying water proofing treatment of sunken portion of WCs, bathroom etc by applying cement slurry with acrylic based modified cementitaous composite compound coating of make as approved in technical instruction 5/2003 (b) First layer of slurry of cement @ 0.5 Kg/Sqm mixed with acrylic based polymer modified cementatious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cure for 4 hours. (c) second slurry of cement @ 0.500 Kg/Sqm mixed with acrylic based polymer modified cementatious composite compounds @ 0.250 Kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (d) 200 micron thick polythene film pasted with the help of bituminous adhesive shall be provided over treatment. (e) Plain Cement 1:5:10 using brick aggregate for sunken filling shall be provided, complete all as specified and directed.[Note : Only plain area considered for measurement] 16 S&F as in repairs closet vitreous China squatting pan, Orissa pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe), complete all as specified and directed. 17 S&F as in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) incl pvc seat cover with hinging devices, complete all as specified and directed. 18 S&F in repairs vitreous China wash basin white, flat back,size 550X450 mm excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, complete all as specified and directed. 19 S&F in repairs 10 litre capacity PVC low level flushing cistern, whitewith all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete (with brackets), complete all as specified and directed. 20 S&F in repairs 15mm bore fancy type stop valve, chromium platedconcealed type cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed. 21 S&F in repairs PVC connection 15mm size PTMT nuts of length 600mm complete all as specified. 22 S&F in repairs 15mm bore pillar taps cast copper alloy,with capstan heads, chromium plated, screwed down, fancy type high pressure, with or without lettred HOT or COLD with long screwed sunk and fly nuts, complete all as specified and directed. 23 S&F as in repairs bib taps cast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed. 24 S&F in repairs health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connections and fixed in positions, complete all as specified and directed. 25 S&F in repairs 15 mm bore brass CP Mixer for mixing hot and cold water screwed down for iron pipe and fixed, complete all as specified and directed. 26 S&F in repairs toilet paper holder with flat recessed type stainless steel arm fixed to walls with chromium plated berass screws, complete all as specified and directed. 27 S&F in repairs waste coupling of PTMT (half or full threaded) 32mm bore dia (min weight 45gm) of discharge pipe, complete all as specified and directed. 28 S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed. 29 S&F as in repairs grating square 150mm size of PTMT (minimum 100 gms), complete all as specified and directed. 30 S&F as in repairs grating square with waste hole 150mm size of PTMT (minimum 100 gms), complete all as specified and directed. 31 S&F in repairs 600 X 450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board for commercial plywood fixed to wooden plugs with chromium plated brass screws and cups, complete all as specified and directed. 32 S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x160mm, complete all as specified and directed. 33 S&F as in repairs tubular towel rail brass chromium plated 20 mm dia `D type 60 cm long between flanges, complete all as specified and directed. 34 S&F as in repairs chromium plated shower roses 125 mm longwith or without swivel joints, any size, including fixing fixing to steel pipe or union, complete all as specified and directed. 35 S&F in repairs stainless steel kitchen plate rack made out of 0.65 mm thick of approved make with plugs, washers, over all size 786mmx610mmx254mm, complete all as specified and directed. 36 M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cemeent to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in Cement Mortar 1:6 including dismantling old unserviceable tiles, complete all as specified and directed. 37 M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqmon vertical surface such as skirtings etc. set and jointed in cement slurryover 10 mm thick rendering in Cement Mortar 1:3 including dismantling old unserviceable tiles, complete all as specified and directed. 38 M&L Non Skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exc. 0.18 Sqm, in floors etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match and including over screed bed or bedding layer of mortar 15 mm thick laying floor finished in Cement Mortar 1:6 including dismantling old unserviceable tiles, complete all as specified and directed. 39 M&L Glazed ceramic tiles Coloured 450 x 350mm 7 to 8 mm thick in wall/dado etc, set & jointedin neat cement slurry & pointed in white or coloured cement to match renderingover 10 mm thick in CM 1:3 on stone masonry surfaces or surfaces other than fair face of brick work/ concrete surfaces including dismantling old unserviceable tiles, complete all as specified and directed. 40 M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite of any type of work including dismantling old unserviceable stone slabs, complete all as specified and directed. 41 M&L 18 to 20 mm thick green marble (table rubbed and polished) in steps, jambs, pillars, window cills,bathroom corners cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with green marble shade including dismantling old unserviceable stone slabs, complete all as specified and directed. 42 Rounding to edges of stone slabs exposededge, such as in steps, cooking platform and other similar situation, complete all as specified and directed. 43 M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete lad over cement screed and jointed over screed bed or bedding layer of mortar 20mm thick in Cement Mortar 1:6 for laying floor finish including dismantling old unserviceable stone slabs, complete all as specified and directed. 44 M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with ditto as per item 36 over 10mm thick in cement mortar Cement Mortar 1:3 including dismantling old unserviceable stone slabs, complete all as specified and directed. 45 Taking down chowkats or frames exc 1.5 sqm but n. exc 4 sqm each with shutters (without taking off shutters from the frame), complete all as specified and directed. 46 Taking down of chowkats or frames not exc 1.5sqm each with shutters (without taking off shutters from frames), complete all as specified and directed. 47 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat of size 50x125 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade ), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS scews having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200N (face) and 1100N (Edge), minimum compressive strength of 58 N/mm2 and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length, complete all as specified and directed.[Note : (i) M.S. hold fast/lugs or SS dash fasteners shall be paid for separately.(ii) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile demension on plus sideshall be acceptable but no extra payment on this account shall be made.] 48 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window/ceosetory windows and other frames/chowkhat of size 50x100 mm comprising of virgin PVC polymer of K value 58-60 (suspension grade ), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms)fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS scews having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200N (face) and 1100N (Edge), minimum compressive strength of 58 N/mm2 and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length, complete all as specified and directed.[Note : (i) M.S. hold fast/lugs or SS dash fasteners shall be paid for separately.(ii) For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile demension on plus sideshall be acceptable but no extra payment on this account shall be made.] 49 S&F Factory made single extruded WPC (wood polymer composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers(wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum frame density of 650 kg/cum, screw withdrawal strength of 1800N (face) and 900N (Edge), minimum compressive strength of 50 N/mm2, modulus of elasticity 850N/mm2 and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixing with stainless steelbutt hings of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. 50 S&F 30mm thick factory made single extruded WPC shutter (wood polymer composite) solid wire gauzed i.e. panel will be of wire gauze in lieu ofpanel. The comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers(wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum frame density of 650 kg/cum, screw withdrawal strength of 1800N (face) and 900N (Edge), minimum compressive strength of 50 N/mm2, modulus of elasticity 850N/mm2 and resistance to spread of flame of class A category with property of being termite /borer proof, water/moisture proof and fire retardant and fixing with stainless steelbutt hings of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.[Note : Stainless steel heavy duty butt hinges with necessary SS Screws shall be paid separately.] 51 S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed. 52 S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed. 53 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed. 54 S&F in repairs 18/19 mm thick prelaminated PVC plain solid ply for shelf andfixed with screws to PVC frame work etc., complete all as specified and directed. 55 S&F in repairs 18/19 mm thick prelaminated PVC solid board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination for shutter, fixed with angle frame work including Stainless steel hinges and magnet catcher, complete all as specified and directed. 56 Supply Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings, complete all as specified and directed. 57 Supply Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, locking arrangement ,C.P. brass/ stainless steel screws all complete as per architectural drawings, complete all as specified and directed. 58 S&F Factory made UPVC white colour Three track three panels sliding window / ventilator with fly proof S.S wire mesh (Two nos. glazed and one no.wire mesh panels) upto 1.50m height made of (big series) frame 122 x 54 mm & sash 47 x 64 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of UPVC multichambered frame, with inbuilt roller track & sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to UPVC profile), appropriate dimension of uPVC extruded glazing beads and UPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed.[Note : (i) Glass or wiremesh shall be paid separately.(ii) For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.] 59 S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, the grill shall be inserted in the wall surface including necessary drilling and grouting with cement etc., complete all as specified and directed. 60 S&F 4.80 mm thick sheet glass, ordinary quality and glazing with rubber gasket & aluminium beading in square exc 0.5 Sqm in each pane, complete all as specified and directed. 61 S&F 5 mm thick figured glass, pin head type and glazing with rubber gasket in squares n exc 0.5 sqm in each pane, complete all as specified and directed. 62 S&F 100 mm long heavy duty butt hinges, extruded alluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed. 63 S&F 75 mm long butt hinges, extruded alluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed. 64 S&F aluminium anodised 150 mm barrel tower bolts of extruded section, complete all as specified and directed. 65 S&F aluminium anodised 100 mm barrel tower bolts of extruded section, complete all as specified and directed. 66 S&F 150 mm long aluminium alloy handles, fabricated type, anodised, complete all as specified and directed. 67 S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as specified and directed. 68 S&F 75 mm long hasp and staple, aluminium anodized with bolt to hinge plate and fixed with screws, complete all as specified and directed. 69 S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and directed. 70 S&F in repairs MS drapery rods of 25 mm dia of PVC coated as in curtain rods, complete all as specified and directed. 71 S&F MS PVC sheeted / power coated bracket size 150 mm made to shape suitable for holding curtain/drapery of rod of 25mm dia fixed with PVC rawl plugs and MS steel screws, complete all as specified and directed. 72 Cutting chases, pinning in making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good, cutting n.exc. 10cm girth, complete all as specified and directed. 73 S&F 20 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11with all fittings (plane and brass threaded) and fixed complete to walls and ceiling or laid in floors including taking down of old unserviceable pipes of 15mm bore, complete all as specified and directed. 74 S&F 25 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11with all fittings (plane and brass threaded) and fixed complete to walls and ceiling or laid in floors including taking down of old unserviceable pipes of 20mm bore, complete all as specified and directed. 75 S&F PVC SWR pipes 160 mm of nominal outer dia of pipe single socketed in any length with rubber ring joint fixed to wall with steel clamps for rain water pipes, complete all as specified and directed. 76 S&F PVC SWR pipes 110 mm bore single socketed in any length with rubber ring joint fixed to wall with steel clamps including dismantling of old unserviceable cast iron pipe, complete all as specified and directed. 77 S&F PVC SWR pipes 75 mm bore single socketed in any length with rubber ring joint, laid in trenches or in floors including dismantling of old unserviceable cast iron pipe, complete all as specified and directed. 78 S&F PVC SWR bends of 160 mm size, complete all as specified and directed. 79 S&F PVC SWR bends of 110 mm bore, complete all as specified and directed. 80 S&F PVC SWR bends of 75 mm bore, complete all as specified and directed. 81 S&F PVC (SWR) junction single (single T) equal or unequal provided with access door of 110 mm dia, complete all as specified and directed. 82 S&F PVC (SWR) junction single (single T) equal or unequal provided with access door of 75 mm dia, complete all as specified and directed. 83 S&F PVC (SWR) floor trap plain including jointing with solvent cement 75 mm dia, complete all as specified and directed. 84 S&F PVC (SWR) vent cowl 110 mm bore, complete all as specified and directed. 85 S&F in repairs for Gun metal gate valve, 20 mm bore, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed. 86 Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr, complete all as specified and directed. 87 M&L old size brick work with fly ash bricks straight or curved on plan exc 6 m mean radius build in Cement Mortar 1:6 including demolition of old unserviceable brickwork, complete all as specified and directed. 88 M&L brick work with half bricks thick fly ash bricks straight or curved on plan exc 6 m mean radius build in Cement Mortar 1:6 including demolition of old unserviceable brickwork, complete all as specified and directed. 89 M&L preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of wood and wood based primer of any description not otherwise described over 10cm width or girth, complete all as specified and directed. 90 M&L preparation of newly plastered surfaces of wall to prepare the surface even and smooth by applying two coat of oil bound distemper over one coat of alkali resistantprimerincl 1mm wall putty for complete smooth surfaces, complete all as specified and directed. 91 M&L preparation of newly plastered ceiling surfaces and preparing the surface even and smooth by applying two coat of oil bound distemper over one coat of alkali resistantprimer incl 1mm wall putty for complete smooth surfaces, complete all as specified and directed. 92 M&L complete removal of old treatment from ceiling surfaces and applying two coat of oil bound distemper for smooth surfaces, complete all as specified and directed. 93 M&L preparation of new plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces, complete all as specified and directed. 94 M&L complete removal of existing treatment by means of mechanical scrubing and dust collector machine and by hand where mechanically cannot reach and washing down with water and applying exterior wall putty on the surface to bring the surface smooth and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces, complete all as specified and directed. 95 M&L complete removal of old treatment of old plastered surfaces of walls andapplying wall putty of 1 mm thick over plastered surface to prepare the surface even and smooth and applying two coat of oil bound distemper over one coat of alkali resistantprimer, complete all as specified and directed. 96 M&L 40 mm thick Plain Cement Concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in roof, finished fair including demolition of old unserviceable concrete/ treatment, complete all as specified and directed. 97 M&L Rendering 10mm thick on fair faces on roof surfaces of concrete surfaces in cement mortar 1:3 finished even and fair, complete all as specified and directed. 98 M&L Preparation new surfaces on roof and applying two coats of polyurethene (PU) water proofing liquid compound over & including one coat of self priming @ one litre per 10 sqm with reinforcing fabric sheet as per manufactures instruction to stop leakage/seepage from roof /wall, complete all as specified and directed.[Note : (i) As per description of these item minimum two coats of polyurethene (PU) water proofing liquid compound over one coat of primer shall be carried out by as per manufacturer instruction. Please note no price adjustment shall be made. If as per manufacturer instructions more coats of polyurethene (PU) water proofing liquid compound& primer are required for roof treatment.(ii) Quoted rate shall be deemed to be included for work in building /structure of any height.] 99 Dismantling wrought iron or mild steel work of any description not otherwise provided, complete all as specified and directed. 100 S&F rolled mild steel in Roof trusses (framed) of steel work in tubular trusses including special shape washers etc., complete using ERW or induction or butt welded tubes conforming to IS:1161-1979 grade St-240, complete all as specified and directed. 101 M&L Plain Cement concrete 1:3:6, type C-1(using 20mm graded stone aggregate) in surface channels and drains and Manholes including demolition of old unserviceable one, complete all as specified and directed. 102 M&L Extra for forming 30 cm inner girth fair finished drains or channels i.e. exc 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified and directed. 103 M&L in repairs 25 mm thick chequered cement concrete tiles of approved size, set, jointed and pointed using with grey cement and pigment in floors, pavings etc including the setting and jointing in neat cement plaster or slurry 0.3 kg/sqm over 20mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed. 104 M&L 75 mm thick cement concrete type C2, for Plain Cement Concrete (1:3:6) using 40 mm graded aggregate used as in sub base, sub floor/pavings and finishing cement concrete surface without using extra cement including demolition the old unserviceable one, complete all as specified and directed. 105 S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling old one, complete all as specified and directed. 106 SCH A PART-II : INTERNAL ELECTRIFICATION 107 Taking down carefully aluminium conductor point wiring (light,fan,socket or power) completeincluding fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing(except those to be reused shall be kept in safe custodyat the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing, complete all as specified and directed. 108 M&L Point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one wayswitch using1.5 sqmm nominal cross sectional areamultistrandedcopper conductor ,PVC insulated unsheathedFRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc., complete all as specified and directed. 109 All as per item No. 2.02 above but5 Amp socket on same boardwith other switches, complete all as specified and directed. 110 All as per item No. 2.02 above but 5 Amp socket on Independent boardwith other switches, complete all as specified and directed. 111 All as per item No. 2.02 above but 5 Amp Calling bell point with other switches, complete all as specified and directed. 112 All as per item No.2.02 above but 5 Amp Two way point with other switches, complete all as specified and directed. 113 M&L Point Wiring for socket outlet 3 pin, 15 amps on independent Boardscontrolled by one, one wayswitch using4.0 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, includingpressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked)fitted with Chromium plated brass screws & washersand 4.0 sqmm nominal cross sectioanl area multistranded copper conductor, PVC insulated unsheathed FRLSH cable earth wire and connecting to earth dolly andbrass screws, washers etc., complete all as specified and directed. 114 S&F switch piano flush type, single pole, 5/6 Amps, one way, complete all as specified and directed. 115 S&F Bell switch piano flush type, single pole, 5/6 Amps, one way, complete all as specified and directed. 116 S&F switch piano flush type, single pole, 6/16 Amps, Two way, complete all as specified and directed. 117 S&F socket outlet 2 in 1 multipurpose5 pin, (6 Amps) flush typecontrolled by one switch duly marked, complete all as specified and directed. 118 S&F switch socket combination 2 in 1 multipurpose 5 pin, (6 Amps flush type controlled by one switch, complete all as specified and directed. 119 S&F switch socket combination 3 pin, (16 Amps) flush type controlled by one switch, complete all as specified and directed. 120 S&F Bell multi music type, AC 230 Volts, single pole 230 volts, complete all as specified and directed. 121 S&F ceiling rose surface bakelite 45 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps, complete all as specified and directed. 122 S&F stepped type electronic fan regulator (min 5 no step) flush type 240 Volts ISI marked, complete all as specified and directed. 123 S&F lamp holder, polycarbonate body with back plate straight or angular suitable for batten fittings, complete all as specified and directed. 124 S&F in repairs submain two single core, 6 sqmm nominal cross sectional areamultistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire, complete all as specified and directed.[Note : 2 Nos. 6.00 Sqm main wire, one No. 6.00 Sqm earth wire & necessary PVC conduit & fittings shall be measured as one run] 125 S&F in repairs wall security light fittings 35 watts 230V, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65/66 including necessary connection complete with all accessories including connected with 3 core copper cable of suitable 1.5 sqmm size, complete all as specified and directed. 126 S&F in repairs 10 W LED light fitting mirror type 2, 220volt AC lighting fixture with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as specified and directed. 127 S&F in repairs LED light fitting 1x 20 W LED batten AC decorative box type with driver, holder including LED tube light conneting up with complete all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete, complete all as specified and directed. 128 S&F Decorative wall light, fixture made up of polycarbonate suitable for 9W LED lamp B22 base, complete all as specified and directed. 129 S&F in repairs 1x9 W LED Inverter bulb, 220volt AC lighting fixture with complete all accessories and connection with twin core twisted flexible copper conductor cable with suitable size and earthing complete,, complete all as specified and directed. 130 S&F in repairs 12 watt surface mounted square LED Down light Colour (CW) aesthetically designed made by aluminium P-die-cast enclousers, with separate replaceable constant current driver 12 watts for grid ceilling including electrical connection, complete all as specified and directed. 131 S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) without remote including taking down old existing ceiling fan & deposited to store, complete all as specified and directed.[Note : Old unserviceable ceiling fan shall be deposited to MES store & necessary receipt voucher & ledger receipt No. be obtained] 132 S&F exhaust ventilation fan with louvers of sweep 225mm, 230 volts 1200 Rpm, with blade and frame and louvers sturdy engineering plastic complete with suitable size of hole, ISI marked including taking down old existing ceiling fan & deposited to store, complete all as specified and directed.[Note : Old unserviceable ventilation fan shall be deposited to MES store & necessary receipt voucher & ledger receipt No. be obtained] 133 S&F exhaust ventilation fan with louvers of sweep 250mm, 230 volts 1200 Rpm, with blade and frame and louvers sturdy engineering plastic complete with suitable size of hole, ISI marked including taking down old existing ventilation fan & deposited to store, complete all as specified and directed.[Note : Old unserviceable ventilation fan shall be deposited to MES store & necessary receipt voucher & ledger receipt No. be obtained] 134 S&F electric water heater (Geyser) storage type steel body with copper inner tank and heating element upto 2KW capacity 25 Litres, BEE 5 star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc., including taking down old existing electric water heater (Geyser) & deposited to store complete all as specified and directed.[Note : Old unserviceable water heater shall be deposited to MES store & necessary receipt voucher & ledger receipt No. be obtained] 135 S&F in repairs epoxy powder coated sheet metal enclosure for DBs, double door(when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact, complete all as specified and directed.[Note : Cable fixed with suitable size Lux and blanker fill with blanker.] 136 S&F in repairs epoxy powder coated sheet metal enclosure for DBs, Double door (when MCBs to be used), tripple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact, complete all as specified and directed.[Note : Cable fixed with suitable size Lux and blanker fill with blanker.] 137 S&F in repairs 240V, 10 KA C curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and directed. 138 S&F in repairs MCB SPN 32 Amps, C series 10kA, 240 Volts and to be housed in DBs complete including necessary connection, complete all as specified and directed.[Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating.] 139 S&F in repairs MCB TPN 25-63 Amps, C series 10kA, 415 Volts and to be housed in DBscomplete including necessry connection, complete all as specified and directed.[Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating.] 140 S&F in repairs 63 Amp MCCB 4 pole, 3 phase, 415 volt of capacity Amp, 16 KA fixed magnetic & thermal setting complete with proper copper thimbles, copper reducer etc, complete all as specified and directed.[Note : Cable fixed with suitable size Lux and blanker fill with blanker.] 141 M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth wire electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased inand including 40 mm dia GI lightgrade pipe from upper end of earth plate upto equipments,20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPlain Cement Concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and Reinforced Cement Concrete pit cover 50mm thick precast Reinforced Cement Concrete 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in Electrical Plate No.3 of SSR Part I complete all as specified and directed and testing on completion.[Note : If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.] 142 S&F in repairs of high pressure PTMT float valve with epoxy coated alluminium rod and high density polythene ball screwed for irom pipe 25 mm bore dia with fly nut, complete all as specified and directed. 143 S&F in repairs 25mm bore GI tubing medium grade in trenches / Floor / pillar connetion in old or new postion including fittings, complete all as specified and directed including taking down old unseviceable pipe. 144 S&F in repairs 40mm bore GI tubing medium grade in trenches / Floor / pillar connetion in old or new postion including fittings, complete all as specified and directed including taking down old unseviceable pipe. 145 S&F in repairs 25 mm bore dia pipe gun metal globe or gate valves, yoke type, full opening with iron wheel head, screwed both ends heavy duty, ISI marked complete for iron pipes, complete all as specified and directed. 146 S&F 40 mm bore dia pipe gun metal globe or gate valves, yoke type, full opening with iron wheel head, screwed both ends heavy duty, ISI marked complete for iron pipes, complete all as specified and directed. 147 S&F in repairs capacity 500 Ltrs rotational moulded polyethylene water storage tanks (Cylindrical, vertical with closed top) 3 layered, white, anti-virus, anti-bacteria, anti-fungal, anti-algae, threaded lid with UV protection, anti microbial, complete including provision of all inlet outlet overflow and drain pipe fittingincluding taking down unserviceable tank, complete all as specified and directed. 148 M&L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16sqmm x 4core laying properly in treanche, complete all as specified and directed. 149 Excavation in trenches not exceeding 1.5m wide and not exc.1.5m depth and getting out in soft/loose soil, complete all as specified and directed. 150 Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil, complete all as specified and directed. 151 Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed. 152 Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying, complete all as specified and directed.[Note : Punned thickness shall be measured.] 153 M&L Sub class B fly ash bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete, complete all as specified and directed. 154 S&F GI Light grade 40 mm dia of size for road cross/cutting on wall floor drain etc., complete all as specified and directed.
Contract Date: Feb 12, 2026 Contract Value : 89.14 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
West Bengal View Result →
31.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
32.
Housing Urban and Rular Development #9456638 Technical Bid
Tender For Tourist Infrastructure Development At Somnath Temple Char, District Chitrakoot, (U.P.), 1 Tourist Infrastructure Development at Somnath Temple Char, District Chitrakoot, (U.P.) 2 BOUNDARY WALL ( 255.00 MTR ) 3 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.All kinds of soil 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 5 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 6 All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum, As in item 6 above but 1:1.5:3 for Footing 7 All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum, As in item 6 above but 1:1.5:3 for Column 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 First Class M-150 brick work in 1:6 cement and coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 10 M-150 brick work in 1:6 cement and Coarse sandmortar in superstructure including supply of all material, labour and tools and plants etc required for proper completion of work for walls of 230 mmthick 11 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) 12 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes 13 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 14 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 15 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 16 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 17 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 18 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 19 PROPOSED ENTRANCE GATE 20 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge.All kinds of soil 21 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 22 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works Upto plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 23 All works Above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum, As in item 3 abovebut inColumn withapproved stone ballast.(Using1:1.5:3Mix concrete) 24 All works Above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum, As in item 3 but for thelighter beams i.e. having spans more than 6 m. (Using 1:1.5:3 Mix concrete) 25 Brick work with class 150 bricks in foundation & plinth in cement mortar 1: 6(1 cement : 6 coarse sand) including all materials, labour, proper curing and T & P etc. required for proper completion of work as directed by Engineer - in -charge. 26 Brick work in super-structure in 1:6 (1 Cement :6 Coarse sand ) above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honey combed brick work for wall of one brick thick etc all complete in direction of engineer in charge. 27 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. 28 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) 29 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - Exposed face machine cut and table rubbed with rough backing. 30 mm thick Red Sand Stone 30 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 31 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-in-charge. 32 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 33 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 34 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 35 INTERLOCKINGTILE PATHWAY 36 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 37 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. 38 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 39 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 40 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 41 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 42 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 43 TREMIX PARING & ROAD 44 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. 45 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. 46 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 47 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 48 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid andinished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). 49 Mildsteel or ironinplainworksuchas reinforcedconcrete orreinforced ,brick work (when not includedin anover all rates )wroughtto required shapeas necessary includingbendingforproper completion of theworkand includingsupplyof steelitswastage bend hooksand authorised overlapping shallbe measured upto floor two level. 50 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. 51 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). 52 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 53 Cost of Bench 54 Cost of Dustbin 55 Cost of Signages 56 Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white orother colour combination including subject matter, message (bilingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge.Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm 57 Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame workfrom the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-incharge.( Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment).Overhead informatory road signage 58 S/F & OFSolar Lighting Complet Etc. 59 TUBE WELL AND INSTALLATION OF SUBMERSIBLE PUMP (90 M. DEPTH) 60 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 300 mm dia 61 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia 62 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia 63 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 64 (0.785*0.4*0.4*90)-(0.785*0.2*0.2*90)=8.478 CUM 65 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit) with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 66 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of :100 mm dia 67 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 100 mm clamp. 68 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 100 mm dia. 69 Supply of submersible pump of make KSB 2.0HP with control panel, support wire etc. complete. 70 Providing 2 core PVC insulated submersibble cable from pump panel to submersible pump 71 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore 72 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 73 Supply of 100mm dia Johnson screen. 74 SEPTIC TANK & SOAK PIT 75 Size :- Length =3.50 M. Width = 2.65M Total Depth =3.00M 76 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-incharge. 77 In all kind of soil 78 In all kind of soil 79 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 80 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) 81 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 82 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work(whennot includedin anover all rates )wroughttorequired shape as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured upto floor two level. 83 15 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand) 84 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar 85 Providing and fixing S.C.I. Tee 150 mm at the inlet and outlet of septic tank. 86 Providing and fixing soil, waste and vent pipes:75 mm diameter Sand cast iron S&S pipe as per IS: 1729 87 Providing & fixing of 75mm dia Sand cast iron S&S as per IS - 1729 terminal guard. 88 Providing & Fixing 75mm plane sand cast iron S&S bend of required drgtee. 89 Providing lead caulked joints to sand cast iron/ cetrifugally cast (squn) irons pipes & fitting of 50 mm dia 90 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.M.D. -10- Circular shape 500mm internal diameter 91 Making soak pit 2.5 mtr dia 3.0 mtr depth 92 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 93 PROPOSED TOILET 94 Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 95 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead 96 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-all work up to plinth level. 1:4:8 (1 Cement: 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) 97 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 98 As in item 4 above but forslabs (Using 1:1.5:3 Mix concrete) 99 As in item 4 but for the lighter beams i.e.having spans upto 6 m. (Using 1:1.5:3 Mix concrete) 100 As in item 4 but for the Footing (Using 1:1.5:3 Mix concrete) 101 As in item 4 but for the Column(Using 1:1.5:3 Mix concrete) 102 Mildsteel or ironinplainworksuchas reinforcedconcrete orreinforced ,brick work (when not includedin anover all rates )wroughtto required shapeas necessary includingbendingforproper completion of theworkand includingsupplyof steelitswastage bend hooksand authorised overlapping shallbe measured upto floor two level. 103 Mild steel or iron workofGrill work etc.wroughttorequiredfromincluding supply ofsteel anditswastage includingcostof bolts, nuts if required forandwelding, grinding andmaking holes as required completion of workfabricationofholesdoors, chaukhats nosing. 104 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 105 Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 106 First Class M-150 brick work in 1:6 cement and coarse sand mortar infoundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. 107 M-150 brick work in 1:6 cement and Coarse sandmortar in superstructure including supply of all material, labour and tools and plants etc required for proper completion of work for walls of 230 mmthick 108 Same as in item no.13 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below 109 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws 110 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood 111 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes 112 Providing and fixing bright finished brass each butt each with necessary screws etc. complete 125x85x5.5mm(heavy type) 113 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm 114 Providing and fixing bright finished brass door latch with necessary screws etc. complete. 300x16x5 mm 115 Providing and fixing bright finished brass handles with screws etc. complete. 125 mm 116 Providing and fixing bright finished brass hangging type floor door stoper with necessary screws etc. compelte. 117 12mm thick plaster with cement mortar consisting of 1 part cement and6 part of approvedsand mortar in 1:6 Minimum thickness not to be less than 10mm. Including supply of all materials, labour and T&P etc. required for proper completion of work. 118 12mm thick plaster with cement mortar consisting of 1 part cement and6 part of approvedsand mortar in 1:6 Minimum thickness not to be less than 10mm. Including supply of all materials, labour and T&P etc. required for proper completion of work. 119 12 mm cement plaster 1:3( 1 cement: 3 coarse sand)finished with a floating coat of near cement 120 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections.. 121 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 122 Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 123 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matchingpigment etc, complete. 124 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 125 Finishing walls with textured exterior paint of requiredshade : New work (Two or more coats applied @3.28 ltr/ 10 sqm) over and including primingcoat of exterior primer applied @ 2.20 kg/ 10sqm 126 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufactures specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work 127 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, toachieve even shade and colour.Two coats 128 French spirit polishing:Two or more coats on works including a coat of wood filler. 129 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured 130 Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. 131 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Medium shade pigment using 50% white cement 50% Grey cement 132 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge.10 x 60 mm 133 Providing and fixing red sand stone brackets 55x22.5x45 cm sunk and moulded including providing and fixing with 4 Nos gun metal cramp 25x6 mm 30 cm long 134 SCHEDULEOFQUANTITIESFORELECTRICALINSTALLATIONS 135 WIRING POINTS AND SUBMAINS 136 Point wiring in PVC Conduit 137 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 138 Power plug wiring in PVC conduit (2 x 4 sqmm.) :- 139 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 140 Circuit / Sub main wiring in PVC conduit :- 141 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 142 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire 143 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 144 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire 145 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 146 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 147 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 148 20 mm. 149 25 mm. 150 32 mm. 151 S/F light plug point modular type accessories :- 152 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 153 S/F power plug point modular type accessories :- 154 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 155 S/F modular type blanking plate :- 156 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 157 DISTRIBUTIONBOARDS,MCBs, MCCBsANDSFUs 158 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door, horizontal type 159 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required single pole 160 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 161 40 amps. 162 63 amps. 163 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 164 Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 165 G.I.EARTHING 166 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 167 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 168 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 169 ERECTIONOFLIGHTINGFIXTURESANDFANS 170 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA 171 Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT- AAA 172 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 173 Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 174 PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES) 175 Providing & Fixing of modular plate type white RJ 45 CAT 6 Data outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required. 1 nos. RJ 45 Data Outlet 176 Supply,installation, testing and commissioningof Main DistributionBoard suitable for upto 125 amp FP MCCB incomer and single / three phase outgoing MCBs, IP 43 protection, double metal door, factory fabricated, wall mounting type in surface / recess, powder coated, 415 V / 200 amp copper Bus Bar, earth and neutral bar, removable gland plates, cable glands including connection with outgoing feeders completeinall respect. DBs shall be original factory fabricated of approved make. The rates shall be excluding all incoming and outgoing circuit breakers. 8 Way TPN 177 PLUMBING WORKS OF TOILET BLOCK 178 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 179 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting and fixtures completed including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests 180 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 181 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 182 32 mm dia (for wash basin) 183 40 mm dia(for sink and urinal) 184 Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 185 Providing & fixing viterous china toilet paper holder. 186 Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal 187 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade 188 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms 189 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 190 Providing and fixing PTMT grating of approved quality and colour. Circular type:125 mm nominal dia with 25 mm waste hole 191 SOIL WASTE & VENT PIPES AND FITTINGS 192 Providing & fixing soil, waste and vent pipes. 193 a) 100mm dia centrifugally cast iron S & S pipe. 194 b)75mm dia centrifugally cast iron S & S pipe. 195 Providing lead Caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fittings of diameters. 196 100 mm 197 75 mm 198 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 199 a) for 100mm dia pipe. 200 b) for 75mm dia pipe. 201 Providing & fixingcast iron coller. 202 a) 100mm dia. 203 b)75mm dia. 204 Providing & fixing upvc SWR bend confirming to IS -14735 110mm dia 205 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 206 a) 100mm 207 b) 75mm 208 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 209 100x100x100mm 210 75x75x75mm 211 Providing and fixingcast iron terminal guard. 212 100 mm 213 75 mm 214 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 215 WATER SUPPLY PIPES AND FITTINGS 216 Providing and fixingGI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). 217 Internal work-Exposed on wall 218 15mm dia nominal bore 219 20mm dia nominal bore 220 25mm dia nominal bore 221 32mm dia nominal bore 222 Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work. 223 15mm dia nominal bore 224 20mm dia nominal bore 225 25mm dia nominal bore 226 32mm dia nominal bore 227 Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. (internal work) Exposed on wall 228 a) 15mm dia nominal outer dia pipes 229 a) 20mm dia nominal outer dia pipes 230 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 231 25 mm nominal bore 232 32 mm nominal bore 233 Providing and fixing ballvalve (brass) of approved quality complete. (High or low pressure with plastic floats). 25 mm nominal bore 234 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. 235 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. 236 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. 237 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. 238 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and makingnecessaryholes for inlet, outlet and overflow pipes but without fittingandbasesupportfor tank. 750 litres capacity 239 SCHEDULE OF QUANTITIES FOR EXTERNAL SEWERAGE SYSTEM - I 240 Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil a) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 241 Providing, laying and joining glazed stone ware pipes grade Awith stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150mm diameter 242 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 150mm diameter 243 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line 244 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. 180 x 150 mm. size P type 245 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 246 Non Schulded Items 247 Supplying and fixing & Fixing Handicapped Toilet Accessories installation in grade 304 stainless steel, 2.0 mm wall thickness(Make Ozone/ Dorma/ Kitch). 248 Providing & Fixing Lift-up Support Rail 249 (L=600mm Ø35mm White) 250 Providing & Fixing Support Rail 251 (L=600mm Ø35mm White) 252 Providing & Fixing Bathroom Handrail 253 (L=300mm White) 254 Providing & Fixing Handrail 255 (L=600mm White) 256 Providing & Fixing Door Handle 257 (L=500mm White) 258 PROPOSED SHOPS WITH CANTEEN 259 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and alllift , as directed by Engineer-in-charge. All kinds of soil 260 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 261 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 8km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 262 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 263 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairingstrength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; Concrete of M25 grade with minimum cement content of 330 kg /cum 264 All Work Up to Plinth Level in M-25 265 All Work Above Plinth Level in M-25 266 Providing centering & shuttering including strutting, propping etc. & removal of form including all materials, labour and T & P etc. required for proper completion of work all complete 267 Foundations, footings, bases of columns, etc. for massconcrete 268 Columns, Pillars, Piers, Abutments, Posts and Struts 269 Lintels, beams, plinth beams, girders, bressumers and cantilevers 270 Suspended floors, roofs, landings, balconies and access platform 271 Reinforcement for R.C.C. workincluding straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars TMTC-500- 272 Diluting and injecting chemical emulsion for POST CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration 273 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 274 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 275 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6(1 cement: 6 coarse sand) 276 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 277 12 mm cement plaster 1:3( 1 cement: 3 coarse sand)finished with a floating coat of near cement 278 Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 279 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 280 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/ 10 sqm) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm 281 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. Two or more coats on new work 282 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured 283 Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. 284 Providing and fixing red sand stone brackets 55x22.5x45 cm sunk and moulded including providing and fixing with 4 Nos gun metal cramp 25x6 mm 30 cm long 285 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 286 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 287 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 288 Frame anchor HRD-C 10x140 289 Frame anchor HRD-C 10x120 290 Providing and fixing glazed shutters for doors, windows and clerestory windows using 5 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. Second class teak wood35 mm thick 291 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 292 Providing and fixing bright finished brass door latch with necessary screws etc. complete : 250x16x5 mm 293 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 294 (a) 250 mm x 10mm 295 (a) 200 mm x 10mm 296 Providing and fixing bright finished brass handles with screws etc. complete:125 mm 297 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to openings /wooden frames with rawl plugs screws etc. 298 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 299 French spirit polishing :Two or more coats on new works including a coat of wood filler 300 SCHEDULEOF QUANTITIES FOR ELECTRICAL INSTALLATIONS WIRING POINTS AND SUBMAINS Point wiring in PVC Conduit 301 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 302 Power plug wiring in PVC conduit (2 x 4 sqmm.) :- Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 303 Circuit / Sub main wiring in PVC conduit :- 304 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 305 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire 306 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 307 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire 308 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 309 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 310 20 mm. 311 25 mm. 312 32 mm. 313 S/F light plug point modular type accessories :- 314 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 315 S/F power plug point modular type accessories :-Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 316 S/F modular type electronic fan regulator :- Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 317 S/F modular type blanking plate :- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 318 S/F MODULAR BOXES, BASE & COVER PLATE :- 319 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required 1 or 2 Module (75 mm x 75 mm) 320 DISTRIBUTIONBOARDS,MCBs, MCCBsANDSFUs 321 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door, horizontal type 322 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required single pole 323 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 324 40 amps. 325 63 amps. 326 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 327 Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 328 G.I.EARTHING 329 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 330 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 331 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 332 ERECTIONOFLIGHTINGFIXTURESANDFANS 333 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 334 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 335 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA 336 Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT- AAA 337 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 338 Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 339 PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES) 340 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperaturerise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep 341 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete 300 mm sweep 900 rpm 342 Supply,installation, testing and commissioningof Main DistributionBoard suitable for upto 125 amp FP MCCB incomer and single / three phase outgoing MCBs, IP 43 protection, double metal door, factory fabricated, wall mounting type in surface / recess, powder coated, 415 V / 200 amp copper Bus Bar, earth and neutral bar, removable gland plates, cable glands including connection with outgoing feeders completeinall respect. DBs shall be original factory fabricated of approved make. The rates shall be excluding all incoming and outgoing circuit breakers. 8 Way TPN 343 CONSTRUCTION OF SHOPS- ( 02 NO.) 344 EARTH WORK 345 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 346 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 347 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 348 ANTI TERMITE WORK 349 Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 350 P.C.C. WORK 351 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from naturalsources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 352 R.C.C. WORK 353 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairingstrength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; Concrete of M25 grade with minimum cement content of 330 kg /cum 354 All works upto plinth level 355 All works above plinth level upto floor V level 356 Providing centering & shuttering including strutting, propping etc. & removal of form including all materials, labour and T & P etc. required for proper completion of work all complete 357 Foundations, footings, bases of columns, etc. for massconcrete 358 Columns, Pillars, Piers, Abutments, Posts and Struts 359 Lintels, beams, plinth beams, girders, bressumers and cantilevers 360 Suspended floors, roofs, landings, balconies and access platform 361 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more. 362 BRICK WORK 363 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 364 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 365 FINISHING WORK 366 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 367 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 368 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 369 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm 370 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 371 DOOR & WINDOW WORK 372 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs ordash fastener shall be paid for separately).Second class teak wood 373 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 374 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 375 Frame anchor HRD-C 10x140 376 Frame anchor HRD-C 10x120 377 Providing and fixing glazed shutters for doors, windows and clerestory windows using 5 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessaryscrews. Second class teak wood35 mm thick 378 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 379 Providing and fixing bright finished brass door latch with necessary screws etc. complete : 250x16x5 mm 380 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 381 (a) 250 mm x 10mm 382 (a) 200 mm x 10mm 383 Providing and fixing bright finished brass handles with screws etc. complete:125 mm 384 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 385 French spirit polishing :Two or more coats on new works including a coat of wood filler 386 FLOORING WORK 387 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone 388 MISSLENIOUS WORK 389 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying aslurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 390 ELECTRICALINSTALLATIONS 391 WIRING POINTS AND SUBMAINS 392 Point wiring in PVC Conduit 393 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 394 Power plug wiring in PVC conduit (2 x 4 sqmm.) :- 395 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 396 Circuit / Sub main wiring in PVC conduit :- 397 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 398 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire 399 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 400 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire 401 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 402 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 403 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 404 20 mm. 405 25 mm. 406 32 mm. 407 S/F light plug point modular type accessories :- 408 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 409 S/F power plug point modular type accessories :- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 410 S/F modular type electronic fan regulator :- Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 411 S/F modular type blanking plate :- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 412 TELEPHONE, TELEVISION AND DATA NETWORK 413 TELEPHONE WIRING IN EXISTING CONDUIT :- 414 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 2 Pair 415 S/F MODULAR BOXES, BASE & COVER PLATE :- 416 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required 1 or 2 Module (75 mm x 75 mm) 417 S/F MODULAR TYPE SWITCH / SOCKET :- 418 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required Telephone Socket outlet 419 DISTRIBUTIONBOARDS,MCBs, MCCBsANDSFUs 420 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 421 4 way (4 + 12), Double door, horizontal type 422 6 way (4 + 18), Double door, horizontal type 423 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required single pole 424 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 425 40 amps. 426 63 amps. 427 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 428 Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 429 G.I.EARTHING 430 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 431 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 432 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 433 ERECTIONOFLIGHTINGFIXTURESANDFANS 434 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 435 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA 436 Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT- AAA 437 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 438 Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 439 PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES) 440 Providing & Fixing of modular plate type white RJ 45 CAT 6 Data outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required. 1 nos. RJ 45 Data Outlet 441 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 1200 mm sweep 442 Supply,installation, testing and commissioningof Main DistributionBoard suitable for upto 125 amp FP MCCB incomer and single / three phase outgoing MCBs, IP 43 protection, double metal door, factory fabricated, wall mounting type in surface / recess, powder coated, 415 V / 200 amp copper Bus Bar, earth and neutral bar, removable gland plates, cable glands including connection with outgoing feeders completeinall respect. DBs shall be original factory fabricated of approved make. The rates shall be excluding all incoming and outgoing circuit breakers. 8 Way TPN 443 PROPOSED CONSTRUCTION OF SHOPS 444 SOIL WASTE & VENT PIPES AND FITTINGS 445 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. a) for 100mm dia pipe. 446 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 447 TOURIST SHELTER 448 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 449 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 450 Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 451 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 452 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 453 Providing and fixing formwork I/c centering, shuttering, strutting, staging, propping bracing etc. completed including its removal for : 454 Foundation, Footing, base of columns and plinth beam in any shape and size upto plinth level. 455 Columns, Pillars, Piers, Abutments, Posts and Struts 456 lintel beam, slab beam, main slab,chajja, septik tank, staircase waist slab 457 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick 458 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 459 All works up to Plinth level. 460 All works AbovePlinth level & upto Floor V Level 461 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeThermo-Mechanically Treated bars of grade Fe-500D or more. 462 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:6 (1 cement : 6 coarse sand) 463 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) 464 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 465 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 466 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 467 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood 468 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 469 Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 470 Frame anchor HRD-C 10x140 471 Frame anchor HRD-C 10x120 472 Frame anchor HRD-C 10x120 473 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete 474 French spirit polishing :Two or more coats on new works including a coat of wood filler 475 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 476 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer 477 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 478 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 479 Providing and fixing aluminium sliding door bolts, ISI marked anodised anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm 480 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm 481 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm 482 Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement..(40mm th.) 483 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. IN : toilet Block 484 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 485 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm 486 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 487 Providing and fixing stainless steel ( Grade 304) railing (Make OZONE /Jindal/ JC Decaux or Equvellent) height 900 mm made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, including fixing accessories such as nuts, bolts, Plats & fasteners (Make Hilti / Bosch/ Power or Equvellent) huse anchor etc. all complete in direction engineer in charge. 488 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineerin- Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 489 Providing and fixing factory made UPVC glazed/wire mess window/ doors comprising of mullion/coupler mesh (where windows/doors ev ever required) comprising of extruded lead 4free uPVCprofiles having mintmum wall thickness of 1.70 mm for series R1 and R2 profiles and 2.10mm for Serles R3 and R4 profilles conforming to EN: 12608 in any shape, colour and designduly relnforced with galvanized mild steel section made of required shape & size as perCPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (whereever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fastenersof minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 gradesleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plasticcaps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, includingdrilling of holes for fixing hardware and drainage of water etc. After fixing frame the gapbetween frame and adjacent finished wall shall be filled with weather proof silicon sealant overbacker rod of approved size and quality, all complete as per approved drawing conformingto CP₩D specification & direction of Engineer-in-Charge._ Section of steel reinforcementand cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge.Wire mesh 1 Glazing of plain/ toughened/ laminated/ double glass unit with / without highperformance coatings as per design requirements and conforming to IS: 3548 & IS: 16231shall be paid separately. Note:-Structural design proofcheckedfromaGovernmentEngineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 mlsec as Using R3 series with frame (55mm & above ) x (45mm & above) & sash /mullion (55mm &above) x (65mm & above). 490 PLUMBING WORKS 491 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. water closet of size 780x370x690 mm 492 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (Make Toto/ Kohlar/ Grohe) 493 (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 494 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. 495 32 mm dia (for wash basin) 496 40 mm dia(for sink and urinal) 497 Providing & fixing stainless steel AISI 304 (18/8) kitchen sink with drain board as per IS :13983 with C.I. bracketsandstainless steel plug 40 mm including painting of fittings and brackets cutting and making good the walls wherever required.510x1040 mm bowl depth 200 mm 498 Providing & Fixing 600 X 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 499 Providing & fixing viterous china toilet paper holder. 500 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade 501 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms 502 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 503 Providing and fixing PTMT grating of approved quality and colour. Circular type:125 mm nominal dia with 25 mm waste hole 504 SOIL WASTE & VENT PIPES AND FITTINGS 505 Providing & fixing soil, waste and vent pipes. 506 a) 100mm dia centrifugally cast iron S & S pipe. 507 b)75mm dia centrifugally cast iron S & S pipe. 508 Providing lead Caulked joints to sand cast iron/centrifugally cast (spun) iron pipes & fittings of diameters. 509 100 mm 510 75 mm 511 Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal size).Including cost of cutting holes & making good the walls etc. 512 a) for 100mm dia pipe. 513 b) for 75mm dia pipe. 514 Providing & fixingcast iron coller. 515 a) 100mm dia. 516 b)75mm dia. 517 Providing & fixing upvc SWR bend confirming to IS -14735 110mm dia 518 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 519 a) 100mm 520 b) 75mm 521 Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 522 100x100x100mm 523 75x75x75mm 524 Providing and fixingcast iron terminal guard. 525 100 mm 526 75 mm 527 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 528 WATER SUPPLY PIPES AND FITTINGS 529 Providing and fixingGI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). 530 Internal work-Exposed on wall 531 15mm dia nominal bore 532 20mm dia nominal bore 533 25mm dia nominal bore 534 32mm dia nominal bore 535 Painting GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work. 536 15mm dia nominal bore 537 20mm dia nominal bore 538 25mm dia nominal bore 539 32mm dia nominal bore 540 Concealed pipe including painting with anticorrosive bitumatic paint, cutting chases and making good the wall. 541 (internal work) Exposed on wall 542 a) 15mm dia nominal outer dia pipes 543 a) 20mm dia nominal outer dia pipes 544 Providing & fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) 545 25 mm nominal bore 546 32 mm nominal bore 547 Providing and fixing ballvalve (brass) of approved quality complete. (High or low pressure with plastic floats). 548 25 mm nominal bore 549 Providing&fixing15 mm nominal bore45 cm long unplasticised PVC connection pipewith brass unions. 550 Providing & fixing 15 mm nominal bore CP brass bib cockof approved quality conformingtoIS 8931. 551 Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved qualityconforming to IS standardsandweighing notlessthan 810 gms. 552 Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conformingto IS8931. 553 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and makingnecessaryholes for inlet, outlet and overflow pipes but without fittingandbasesupportfor tank. 554 750 litres capacity 555 SCHEDULE OF QUANTITIES FOR EXTERNAL SEWERAGE SYSTEM - I 556 Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. 557 Providing, laying and joining glazed stone ware pipes grade Awith stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150mm diameter 558 Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 150mm diameter 559 Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line 560 Providing and fixing square mouthS. W. Gully trapgrade `A complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type 561 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 562 ELECTRICALINSTALLATIONS 563 WIRING POINTS AND SUBMAINS 564 Point wiring in PVC Conduit 565 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C 566 Power plug wiring in PVC conduit (2 x 4 sqmm.) :- Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 567 Circuit / Sub main wiring in PVC conduit :- 568 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 569 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. Earth wire 570 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire 571 4 x 6 sq.mm. + 2 x 6 sq.mm. Earth wire 572 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 573 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 574 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required 575 20 mm. 576 25 mm. 577 32 mm. 578 S/F light plug point modular type accessories :- 579 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required 580 S/F power plug point modular type accessories :- 581 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 582 S/F modular type electronic fan regulator :- Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 583 S/F modular type blanking plate :- Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 584 S/F MODULAR BOXES, BASE & COVER PLATE :- 585 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches inrecessetc as required 1 or 2 Module (75 mm x 75 mm) 586 S/F MODULAR TYPE SWITCH / SOCKET :- 587 Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required Telephone Socket outlet 588 DISTRIBUTIONBOARDS,MCBs, MCCBsANDSFUs 589 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 590 4 way (4 + 12), Double door, horizontal type 591 6 way (4 + 18), Double door, horizontal type 592 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required single pole 593 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 594 40 amps. 595 63 amps. 596 Supplying & fixing single pole, blanking plate in the existing MCBDBcomplete etc. as required. 597 Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 598 G.I.EARTHING 599 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 600 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 601 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 602 ERECTIONOFLIGHTINGFIXTURESANDFANS 603 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 604 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 605 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA 606 Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT- AAA 607 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 608 Supply and fixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA 609 PART (B) -- NON SCHEDULED ITEMS (AS PER MARKET RATES) 610 Providing & Fixing of modular plate type white RJ 45 CAT 6 Data outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required. 1 nos. RJ 45 Data Outlet 611 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperaturerise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make : Bajaj / Crompton / Havells) 1200 mm sweep 612 Supply of AC230/250 volts, 50 HZ exhaust fansincluding providingnuts, bolts, mounting frame and other accessories etc.complete (Make : Bajaj / Crompton / Havells) 300 mm sweep 900 rpm 613 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
West Bengal View Result →
34.
Defence #9393772 AOC
Tender For Provision Of Pi Mess For Jcos/Or At Ncc Gp Hq Gorakhpur; 1 Lump sum price worked out by the contractor as per showm on drawing for Building Work as listed in Sch ‘A’ PartI. 2 Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch A Part II. 3 Lump sum price worked out by the contractor for Internal Electrification as listed in Sch A Part III. 4 Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch A Part IV. 5 Lump sum price worked out by the contractor for Path as listed in Sch A Part V. 6 Lump sum price worked out by the contractor for Area Drainage as listed in Sch A Part VI. 7 Lump sum price worked out by the contractor for External Electric Supply as listed in Sch A Part VII. 8 Lump sum price worked out by the contractor for External Water Supply as listed in Sch A Part VIII. 9 Lump sum price worked out by the contractor for Site Clearance and Earth Work as listed in Sch A Part IX. 10 Price item wise worked out by the Contractor forSchedule `A Part-X (rate against Srl No. 11.0 to 22.00 shall be quoted by the Contractor) 11 S&F metal flush box 12 module, made of 1.6mm thick sheet, for mounting modular switches and sockets complete all as specified and directed. 12 S&F white modular cover plate with frame 12 module, for modular switches and sockets complete all as specified and directed. 13 S&F metal flush box 8 module, made of 1.6mm thick sheet, for mounting modular switches and sockets complete all as specified and directed. 14 S&F white modular cover plate with frame 8 module, for modular switches and sockets complete all as specified and directed. 15 S&F wall mounted fan voltage 230V, 50 Hz, RPM 1330, copper winding of sweep 400mm, swing high speed, pul cord control for speed and oscillation ON-OFF, including mounting accessories kit complete all as specified and directed. 16 Material and labour Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5metre below the ground level connected to GI strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 40 mm bore medium grade for protection of earth strip and 20 mmbore medium GI pipe for watering including adequate quantity of charcoal dust and common salt around earth plate,PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways, charcoal dust and common salt, all as shown in electrical plate No. 3 of MES SSR part-I and making test point as specified including excavation & earth work in any type of soil and connecting the earthing to an earthing point/equipment & testing on completion complete all as specified and directed. 17 Boring of holes under road, pavement, hard standing manually including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. 18 Supply, install, testing and commissioning of LT Cubicle panel of suitable size, outdoor type(Slopy roof), platform mounted, totally enclosed, dust and vermin proof, openablefrom both front and rear side, double door, outdoor sheet made out 3.15mm and indoor sheet of 2mm thick CRCA sheet complete including inner chambers/partitions to mount the following electrical accessories and built upon 50x50x6mm angle iron frame work, having front and rear hinged doors with 04 Nos hinges on each leaf, lifting lugs (2 Nos), provision for earth strip connection, bottom detachable gland plates, connecting using suitable size of zinc plated and passivated nut, bolts, springs and washers. The cabinet and all members should be chemically treated with anti-corrosive chemicals with 3 tank phosphating method and apply powder coatingwith oven heating. The panel should be suitable for 415 volts, 50Hz, 3 phase 4 wire system 1100 volts grade, with copper bus bar of 200 Amps capacity rating coloured heat shrinkable sleaving, internal connection should be provided with aluminium strip of suitable size and necessary grouting/ foundation all as required at site and comprising of following :-Incoming(a) MCCB 125Amps, 35 KA, 3 Phase, 4 pole,microprocessor based with overload protection adjustable rating of 30%to 100%in variable time rating short circuit protection adjustable type range 400% to 1000% with variable time setting , ground fault adjustablein range 10% to 40% of variable time setting -01 set 19 (b ) Ammeter96 mm square digital type with selector switch and cpper wounded CT with ratio 125/5 Amps including necessary connection of suitable size of copper wire-01 set(c) Voltmeter 0-500V -01 No digital type 96 mm square with selector switch including necessary connection with suitable size ofcopper wire - 01 set(d) LED indicator lamp(R-Y-B)- 01 setOutgoing(a) MCCB100A, 35 KA. 3 Phase, 4 pole,microprocessor based with overload protection adjustable rating of 30%to 100%in variable time rating short circuit protection adjustable type range 400% to 1000% with variable time setting , ground fault adjustablein range 10% to 40% of variable time setting -01 No (b) -do but of MCCB 63 Amps, 35 KA, 3 Phase, 4 pole - 01 No (spare)(c) MCB TPN 32 Amps - 01 No(d) MCB SPN 10 Amps-01 No(e) Astronomical Timer relay alongwith 63 Amps TP Contactor and 40 Amps MCB for each circuit for street light-01 20 S&F Weather Proof thermo plastic (Polysterene) Cable Junction box , having protection class IP-66 and of overall size 210mm x 155mm x 92mm having metric knockouts on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymide weather proof cable glandsof cable sealing range 10mm to 17mm (Complete with check nut) and including 1 No 30 Amps with cable connector and 1 No. 6 Amps SP MCB. 21 Supply, laying & testing PVC insulated , PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sqmm, 3 core, 1100 volts grade draw from junction box to street light fitting complete all as specified and as directed. 22 M&L for construction of brick masonry valve pit of size 600mm x 600 mm x 600 mm (internal dimensions of chamber) depth to be reckoned from the top of PCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 x 40 x 6 mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr 15 cm thick PCC 1:4:8 type D-2 in PCC foundation projected by 15cm all round from the outer face of brick wall PCC 1:2:4 type B-1 in coping complete all as specified. 23 Cutting, existing cast iron pipe for new connection alteration including screwing in position for branch connecting size 50mm bore complete all as specified and directed.
Contract Date: Feb 06, 2026 Contract Value : 79.57 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
Uttar Pradesh View Result →
35.
Power #9347262 Technical Bid
Annual Maintenance Routine Maintenance and operational support of Electro Mechanical Equipment installed at 450 MW (3x150) BHEP Stage-II including |EOT cranes, 1250 KVA DG set and CCTVs installed in power house of BHEP-II for TWO years- Manpower for Routine Maintenance of power Plant of BHEP-II 2 Manager MBA/B.E/B.Tech(Electrical) 3 Engineer (B.E/B.Tech Electrical) 4 Engineer (B.E/B.Tech Mechnical) 5 Operational assistance Engineer 6 Operational assistance Technician 7 Electrician Highly skilled 8 Welder cum Grinder 9 Mechanic/ fitter highly skilled 10 Electric Crane operator 11 Helper Skilled 12 Cook,Mess helper etc. 13 Sweeper/floor cleaner 14 Hiring charges of vehicles INCL POL for (20 persons)(These charges has been fixed as per the approved estimate) for 24 months 15 Accomodation for outstationed manpower including food (max 5 persons)(These charges has been fixed as per the approved estimate) for 24 months 16 CONSUMABLES, TOOLS TACKLES AND WELDING MATERIAL & OTHER MISC. ITEMS TO BE ARRANGED BY THE CONTRACTOR(FOR ROUTINE MAINTENANCE of One year) 2025-27 17 Cotton waste 18 M-seal (100 gm pack) 19 Teflon tape, Champion 3/4”x 12 M 20 Fevi quick 2 gm 21 Hexa blade 1”x12” 22 Diesel 23 Petrol 24 Mineral Turpentine oil 25 Malmal cloth 26 Markin cloth 27 Duster cloth 28 Emery cloth tape 150 mmx50mtr. Coarse P120 29 LED Bulb 12 watt (Jaguar, Crompton, Havells make) 30 Socket 16A (Havells, Anchor, Goldmedal make) 31 Top 16A (Havells, Anchor, Goldmedal make) 32 Switch 16A (Havells, Anchor, Goldmedal make) 33 Socket 6A (Havells, Anchor, Goldmedal make) 34 Top 6A (Havells, Anchor, Goldmedal make) 35 Switch 6A (Havells, Anchor, Goldmedal make) 36 Led flood lights 100 watts(Havells, Jaguar, Philips make) 37 Led flood lights 50 watts(Havells, Jaguar, Philips make) 38 SPCL-440 V2 Card for Battery charger 48V 39 Amaron Quanta 12V 40AH SMF-VRLA battery 40 OPzS 1200P 1200AH/2V Tubular plate battery 41 YKP-17 cell 200AH/2V Tubular plate battery 42 Halogen tube 1000 Watts with Holder(Havells, Jaguar, Philips make) 43 Loctite 406 (20gram) 44 Loctite 243 (250ml) 45 Cotton knitted single side PVC dotted safety hand gloves 46 Marker pens 47 CRC 226 (500ml) 48 CRC BATTERY PROTECTOR 500 ML Can 49 CRC BATTERY CLEANER 500 ml Can 50 CRC-CO contact cleaner (400ml) 51 PVC tape/insulation tape (Havells, Anchor, Goldmedal make) 52 Mega duster barber dusting brush ( Long Nozzle) 53 Cobweb duster with extendable handle 54 Spin Mop with Big wheeled bucket 55 Dust Pan Big size 56 Sponge Mop 57 Feather Dusters 58 Angular toilet Brush with storage holder 59 Cellulose sponges 60 Hazard Sign Boards (Wet Floor, Man at work, Machine under shut down, Dont operate etc) 61 Marble and Granite cleaner 62 Collin spray (500ml) 63 Detergent cakes (250gm) 64 Liquid-Handwash (250ml) (Dettol, Savlon, Lifeboy make) 65 MCB SPN/DPN 16A,32A (Havells, Schneider, ABB make) 66 Single core wire FRLS 4mm2 (Polycab, Havells, KEI make) 67 4-core cable FRLS 2.5 mm2 (Polycab, Havells, KEI make) 68 2-core cable FRLS 4 mm2 (Polycab, Havells, KEI make) 69 LED bulb screw type 9W (Havells, Jaguar, Philips make) 70 Pocket Torch Rechargeable LED type Telescopic zoom and adjustable focus , Aluminium body 71 Power hexa blades 72 Thinner ICI 73 Nuts & Bolts of various sizes (12x80 mm SS,06x20 mm,08x30mm,10x60 mm,12x70 mm,16x85 mm) 5 kg each with separate packing 74 MP grease/ Lithium based oil Grease 75 RCCB, 63A, 4 pole TPN (Havells, Schneider, ABB make) 76 Hydrometer 77 Tarpaulene & plastics 78 Metal Exhaust Fan 14 inch (Crompton, Havells make) 79 Partially threaded Allen key bolts M20 x 95mm 80 3 Phase contactor,85 A,415 V ( L&T MNX 45 contactor) 81 250 A ,415 V TPN (Havells, Schneider, L&T make) 82 Add on blocks with 2 NO & 2 NC Contacts (LADN 22 , Schneider make) 83 Plastic trays,15 litres capacity 84 Electric Kettle 2 ltr (Prestige, Milton, Pigeon make) 85 Thermosteel Flask 1 ltr ( Milton, Cello, Borosil make) 86 A4 Size Paper 87 wire lugscopper 1 sqmm 88 wire lugs copper 2.5 sqmm 89 wire lugscopper 4 sqmm 90 wire lugs copper 6 sqmm 91 wire lugs copper 10 sqmm 92 Nose plier (Stanley, Taparia, Tata Agrico make) 93 Combination Plier (Stanley, Taparia, Tata Agrico make) 94 Anabond 666 silicone RTV 95 Tap sets 4mm to 18mm 96 Measurement tapes 5 mts 97 Rubber Hose ¾” 98 Rubber Hose 1” 99 Nitrogen gas 250 Bar, 10 Cum capacity,99.99 % purity 100 Floor Mops 101 Floor Brooms 102 Floor Wipers 103 Srubbers 104 Phenyl 105 Dust Bins,60 litres capacity 106 Detergent powder,60 grams pouch (Surf, Tide make) 107 Buckets,25 litres capacity 108 Nepthalene balls 109 Plastic trays,5 litres capacity 110 Flush cleaners, 1 litres each 111 Contacts of starter for Dewatering pumps 110 kw each 112 EXCITATION PANEL FILTER CLOTH 113 LED Batten rod 18watt 2 ft (Philips, Havells, Crompton make) 114 LED Batten rod 36 watt 4 ft (Philips, Havells, Crompton make) 115 Manila Rope 20mm 116 Electrical Pole climbing clip 117 Wired computer mouse (HP, Dell, Sony make) 118 Wired computer keyboard (HP, Dell, Sony make) 119 Wireless Bluetooth computer mouse (HP, Dell, Sony make) 120 Wall clock (Big size) 121 Office Desktop All in one type (Intel i5, 13th gen H processor , 500 GB SSD, 16 GB RAM, minimum 21 inch display, Windows and Microsoft office licenced version pre-installed) (HP, Dell, Lenovo make) 122 Tea, coffee edible refill packs for 24 months 123 3 Phase power contactor LC1F265 (Schneider make) 124 Panel locks as per sample 125 PU foam insulation Sealant spray (750ml) Loctite make 126 1TB SSD External Portable Drive USB 3.2 (Sandisk, Samsung, Seagate make) 127 Pendrive 64 GB capacity USB 3.0 ( Sandisk, samsung, seagate make) 128 2x2 LED panel Cold white color (Philips, Crompton, Havells make) 129 Welding and Miscellaneous itemsfor 3 Machines 130 Grinder Wheel AG 4 (Bosch, DeWalt make) 131 Grinder Wheel AG 5 (Bosch, DeWalt make) 132 Grinder Wheel AG 6 (Bosch, DeWalt make) 133 Cutting Wheel AG 4 (Bosch, DeWalt make) 134 Cutting Wheel AG 5 (Bosch, DeWalt make) 135 Cutting Wheel AG 6 (Bosch, DeWalt make) 136 Tools, LED and camera to be supplied by contractor(for RMC) 137 LED Bulk head light CW10W Rectangular shape (Philips, Jaguar, Havells make) 138 Self adjusting 2 in 1 Automatic wire striper cutter 0.25 - 6 sqmm capacity (Stanley, Ingco make) 139 Bosch cordless drill/driver 12V with double battery ( 10mm chuck size) 140 Electric Impact wrench 1050W 550Nm torque 2300 rpm (8mm to 32mm socket compatible) along with 20 Pcs Impact Socket set 1/2 inch Impact socket set 8mm - 32 mm with 3 pcs Drive Impact Extention Bar set 3, 5, 10,(DEWALT, Hydac make) 141 Battery operated cordless Impact wrench with battery, Charger and accessories, Torque 370 Nm (8mm to 32mm socket compatible) (DEWALT, Hydac make) 142 Wire lug Pin type for panel wiring (for 0.75 - 1.5 sqmm wire) 50 pcs each 143 Underwater 12W LED wall mounted CW with Driver light for DT cone lighting 144 Refill Ink set for Hp 5820 printer ( Black& red ,yellow ,Blue) 145 200 Watt, High Bayprotection suspend able with Integrated Surge driver, Protection10KV. Epoxy powder die-cast aluminium Coated housing, Viewing angle 120° wide beam, > 130Lm/w, colo temperature5700K, THD 10%,. IK Rating IK07 CRI >70, 50K average Lite Hrs. system lumns 25000 with BIS certification (Crompton make) 146 100 W street light with clamp, Viewing angle 160° wide beam, IP 68 waterproof (Philips, Jaguar, Havells make) 147 2 MP infrared Bullet CCTV camera(Hikvision, CP Plus, Sony make) 148 2 MP infrared Dome CCTV camera(Hikvision, CP Plus, Sony make) 149 CCTV Technician mandays ( Through Authorized service parter, The service of the Authorized engineer shall pe used as per requirement. The requirement shall be intimated one week prior and the mandays shall be utilized as per requirement) 150 1250 KVA DG service 151 Servicing of 1250 Kva1500 RPM, 50 Hz,3 Phase Cummins make DG setwhich shall include changing of engine Oil, Topping up of Coolant, Cleaning The radiator and fixing any leakage, Checking and cleaning of all the terminals , Cleaning the self, solenoid valve etc, Changing of all the oil and Air filters as required at site including fixing back all the parts and checking the DG on Full Load. The servicing of DG should be provided through OEM or its Authorized dealer 152 Cummins Pulse Lite 12V 160Ah Genset Battery 153 150/35/2 ton EOT crane at machine hall BHEP-II (UNIQUE MAKE) 154 Emergency corner switch 1 pole, 2-way, 250 V AC10AKaycee 155 Selector switch, single pole, 3 ways with off16A, 250VACKaycee 156 Emergency Stop push Button, push to trip, and turn to release, Colour: Red6A, 230 V ACSiemens/ L&T 157 Gravity Limit Switch, Double contact40A, 500VACSOC/ Omega/ EMM 158 Anti-collision limit switch, Infra-red type110-230VElectronic Switches/ P&F 159 Rotary Geared Limit Switch Two way40A, 500V ACSOC / EMM/ Omega 160 Lever Operated Limit Switch One way40A, 500V ACSOC / EMM / Omega 161 Lighting transformer 415/240V Double wound with + 5 % and + 10% tapping on primary3.5 KVAIndcoil/AE 162 Control transformer 415/110V Double wound with + 5 % and + 10% tapping on primary750 VAIndcoil/AE 163 Dynamic Braking resister8.1 Ohm, 22.5 KWIRESCO/SOC 164 Dynamic Braking resister14 Ohm, 1.85 KWIRESCO/SOC 165 Dynamic Braking resister14 Ohm, 3 KWIRESCO/SOC 166 Dynamic Braking Resistor100 Ohm, 2 KWIRESCO/ SOC 167 VVVF Drive, Variable speed drive45 KW, 94 ASchenider / Yaskawa 168 VVVF Drive, Variable speed drive18.5 KW, 41 ASchenider / Yaskawa 169 VVVF Drive Variable speed drive30 KW, 66ASchenider / Yaskawa 170 Disk Brake with Motor-BBL/ Marathon Electric 171 Disc Brake-PETHE 172 EHT Brake 300mm Dia415 V ACEMM / SOC / BCH 173 PLC: Type: TM238LFDC24DTSO Digital Inputs Module TM2DED18DT-Schneider-Electric 174 SMPS24 DC, 10.5 ASchneider-Electric 175 Master Controller 5 Steps 8 Cams10:00 AMSOC/EMM/Omega 176 Plug and socket Metal clad for 240 V AC20A , 250V ACSchenider 177 Main Isolator 3 pole with Neutral200 A, 690 VACSiemens/L&T/ Schenider 178 Power Contactor (Main contactor), 3 pole with 2NO + 2NC Contact185 A, 415 VACSiemens/L&T/ Schenider 179 MPCB (To be set at 2A), 3 Pole (1 NO + 1 NC) Aux Contact1.6 - 2.5 ASiemens/L&T/ Schenider 180 Panel Heater Type: SH/006/14560w, 230V ACGirish - EGO 181 Pulse Encoder 10- 30V DC1024-PPRPepperl+fuchs/Hubner 182 Thermal Overload Relay12-18ASiemens/ Schneider / L&T 183 7.5 ton EOT crane at GIS hall BHEP-II (GRIP make) 184 MHT Control HRC fuse63ASiemens 185 MHT Brake HRC fuse10ASiemens 186 MHT HRC fuse4ASiemens 187 CT HRC Fuse10ASiemens 188 CT HRC Fuse4ASiemens 189 VVVF AC Drive (Model: A1000)18.5 KWYaskawa (L&T) 190 VVVF AC Drive (Model: V1000)0.75 KWYaskawa (L&T) 191 Snap Action type Limit Switch10ASiemens 192 CT Lever Action Limit switch40ASOC 193 Main Contactor /110V32ASiemens 194 Brake Contactor, 110V AC25ASiemens 195 Brake Contactor, 110V AC9ASiemens 196 Transformer 415/110v200VALOGICSTAT 197 Heater with Thermistor 220V AC10WANCO 198 Push Button (2NO + 1NC) 2 stage10ASchneider 199 Rectifier Unit190V DCEMCO 200 Thermal Overload Relay0.9 - 1.25ASiemens 201 EOT Engineer mandays ( Through Authorized service parter, The service of the Authorized engineer shall pe used as per requirement. The requirement shall be intimated one week prior and the mandays shall be utilized as per requirement) 202 Manpower for Annual Maintenance of power Plant of BHEP-IIFor3 Machines 203 Engineer(B.E/B.Tech Electrical) 204 Engineer(B.E/B.Tech Mechanical) 205 Supervisor( Diploma) 206 Electrican (Highly skiled) 207 Welder cum Grinder 208 Mechanic/ fitter(Highly skilled) 209 Electric crane operator 210 Painter 211 Helper skilled 212 Cook,Mess helper etc. 213 Hiring charges of vehicles INCL POL for 40 manpower (These charges has been fixed as per the approved estimate) for 06 nos jobs 214 Accomodation for outstationed manpower including food (max 10 persons) (These charges has been fixed as per the approved estimate) for 06 nos jobs 215 CONSUMABLES, TOOLS & TACKLES, WELDING MATERIAL AND OTHER MISC. ITEMS TO BE ARRANGED BY THE CONTRACTOR FOR ANNUAL MAINTENANCE For 3 machines (For two years) 2025-27 216 Cotton waste 217 M-seal (100 gm pack) 218 Sandering disk 219 Vaccum oil 220 Teflon-tape, Champion 3/4”x 12 M 221 Gear oil 222 Fevi quick 2 gm 223 Hexa blade 1”x12” 224 Diesel 225 Petrol 226 Mineral Turpentine oil 227 Aeroshell-41 Hydraulic oil of GIS CB 228 Red insualtion varnish F Class Stanvac Crown 229 Carbon Brushes (Mersen make, Model no. E6340215879) 230 Isopropyl alcohol 231 Turbine Flat seal (4x8 mm ) as per sample 232 Line tester (Stanley, Taparia, Pye make) 233 Colgate Powder ( 400 gm) 234 Sling of capacity 2 ton (2mtr) 235 Sling of capacity 3 ton (3mtr) 236 Sling of capacity 5 ton (7mtr) 237 Sling of capacity 20 ton (10mtr) 238 Sling of capacity 40 ton (15 mtr) 239 Rain wear Jacket (100% waterproof) of Reputed make( l,xl,xxlsize) (Wildcraft, Adidas, Nike make) 240 LeatherHigh ankle Steel toe Safety shoes Black color (Woodland, Allen cooper, Liberty make) (of various sizes 6,7,8,9,10 mix as per site requirement) 241 Dongri ( m,l,xl,xxl) of Reputed make 242 Safety helmet with attached/inbuilt torch (Black Decker, heapro, Braid agro make) 243 Welding goggle 244 Grinding / safety goggle (Reputed make) 245 Cable Tie of various sizes 246 Heavy duty water proof Tarpoline sheet - 30x30 feet 247 Malmal cloth 248 Markin cloth 249 Duster cloth 250 Rust remover (WD 40 Pidilite make, CRC Rust remover concentrate) 251 Emery cloth tape 150 mmx50mtr. Coarse P120 252 LED batten 10inch 10W for panel (Havells, Goldmedal, Philips make) 253 Socket 16A (Havells, Anchor, Goldmedal make) 254 Top 16A(Havells, Anchor, Goldmedal make) 255 Switch 16A(Havells, Anchor, Goldmedal make) 256 Socket(6A)(Havells, Anchor, Goldmedal make) 257 Top 6A(Havells, Anchor, Goldmedal make) 258 Switch 6A(Havells, Anchor, Goldmedal make) 259 LED Flood light 50 watt, 100 watt (Havells, Jaguar, Philips make) 260 Silica GEL Beads 2-5mm 261 LOCTITE 262 Loctite 510- 50 ml tube (High temperature resistant) 263 243 (250ml) 264 Gasket maker Red (Anabond) 265 Anabond Auto Gasket maker Red (High temperature RTV Silicone 85 gm tube 266 Paint brush (3 and 4) 267 Pencil Brush 268 D.P.T (Cleaner 300ml, Developer 300ml, Penetrant 300ml) 269 Cotton knitted single side PVC dotted safety hand gloves 270 Buffing Wheels 271 Marker pens 272 CRC 226 (500ml) 273 PVC tape/insulation tape (Havells, Anchor, Goldmedal make) 274 CRC-CO contact cleaner (400ml) 275 Collin spray (500ml) 276 Detergent cakes (250gm) 277 Handwash liquid (200ml) (Dettol, Savlon, Lifeboy make) 278 MCB 10A/16A/32A ratings 279 3 Phase Power contactors ABB make A26-30-10 280 Perchlroethylene/white spirit for cleaning 281 Molykote paste Grease (Dupont make) 282 4 core FRLS wire 2.5mm2 (Polycab, Havells, KEI make) 283 2 core FRLS wire 4mm2 (Polycab, Havells, KEI make) 284 Single core FRLS wire 4mm2 (Polycab, Havells, KEI make) 285 Single core FRLS wire 2.5mm2(Polycab, Havells, KEI make) 286 Rechargeable torch/emergency lights(Heavy Duty) 2200 mAH battery with 4 hour backup (Havells, Jaguar, Philips etc make) 287 Hand Torch Rechargeable 6W LED type (Havells, Jaguar, Philips make) 288 Power hexablades frame only 289 Rubber sheets (3mm & 4mm) as per sample to with stand requisite pressure 290 Champion sheets (various sizes 3mm, 4mm & 5mm) as per sample to with stand requisite pressure 291 Adduct Cycloaliphatic, Anticorrosion,Immersion Grade Epoxy lining coating in spiral casing 292 Ist-qualityEnamel Paint for turbine Pit & Lower bracket & otherequipments, like MIV Governor, Bypass walls, Cooling water system compressors high injection pumpsexposed to water (Different Colours)(Asian Paint, Nerolac, Berger paints make) 293 Thinner ICI 294 MP grease/Lithium based oil Greese (Bosch, Castrol, Mobil make) 295 Red Oxide Primer (Asian Paint, Nerolac, Berger paints make) 296 Hydrometer 297 Vaseline Petroleum jelly 298 Gravity water with SG 1.255 for Battery banks 299 Hygrometer 300 Valvoline Tectyl 506(cleaning anti corrosion for shaft 301 Zincbrite ( shiny cold galvanizing coating 400ml) 302 PLC battery 6ES79710BA00: 3.6 volt TADIRAN make 303 Oil combination stone 304 Fast Steel Putty Loctite make 305 Welding Material & other misc items to be supplied by the contractor for AMC for 3 machines 306 Welding electrode 6013 3.15mm (MS) 307 Welding electrode 7018 3.15mm (MS) 308 Tools & tackle to be supplied by contractor(for AMC) 309 Paint Rollers 9 inch 310 Paint roller 4 inch 311 Nylon Nitrile coated industrial hand gloves (Water proof) 312 Waterproof pant and carry Pouch with reflective strips ( Double layered tapping rubberized fabric) 313 Gum Boots (Different sizes) 314 Nylon coated steel speed cable 2.5mm size, 5 mtr length 315 Slogging spanner ring (24mm to 75mm size, 1 piece each) Stanley, Taparia, Tata Agrico make 316 Ring spanner (6-32) Stanley make 317 D Spanner (6-32) Stanley make 318 Ring and D combination spanner (36mm to 42mm, 1 piece each) Stanley make 319 Scaffolding system (cup lock type) made with 40mm dia M.S. tube for 3.5 x 3.5 area upto 3.5 m height 320 High energy lithium battery SL-350 PLCC make Tadiran 321 Gasket maker manual machine 322 Chemical respirator paint gas mask ( Double cartridge, Double filter mask, Half face) 3M make 323 HVLP Paint sprayer gun 500W air painting tool with electrical fan sprayer 324 Wire brush 325 3 mtr long straw cleaning brush stainless steel with tiny nylon bristles for tube cleaning 326 Sponge (2 ft x 2 ft x 4 inch) 30 kg/m3 density 327 Tap set 16 mm-18 mm 328 Reducer 1.5/1 inch SS material 329 Bolt Stainless steel Instant read Round dial analog thermometer 18 inch 330 5mm screw type stud 50 mm length with nut 331 Mallet hammer 500 gm 332 C clamp 100-150 mm 333 Hose pipe ½ inch (heavy duty) suction type 334 0.5 HP centrifugal pump crompton, havells make 335 Nuts and Bolts of Stainless steel as per sizes mentioned in Annexure attached with SBD 336 WaterproofHeavy duty water leakage Aluminium foil insulation tape 5mtr x 10 cm (3M make) 337 D-Shakle (2 to 12 ton capacity) 4 pcs each 338 Lifting Eye Bolt SS (M4to M24) 5 pcs each 339 Sling of capacity 10 ton (10mtr) 340 Brady Arrow tape, Vinyl, 2 inch W x 90 ft L adhesive mouting White/Green 341 Paint Roller 9 inch with 10 ft long handle 342 Bench Vice 105mm x 200 mm x 205 mm, 27 kg 343 45mm 1380 watt magnetic core drill with accessories (MEGA 45) with drill bits of all sizes 2 nos each, Ralli Wolf make 344 Bosch 160 Bar 600 LPH 8 m High Pressure Washer 2600 W, Advanced Aquatak 160 345 150mm Frame level, No. 122545, Accuracy 0.02mm/m, RSK make 346 Hydraulic power wrench 27-65 mm socket compatible Ultra thin low profile Hex Cassette with hydraulic power pack including compatible socket set 27mm to 65 mm 347 Anabond Glue Gun
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Jammu And Kashmir View Result →
36.
Law and Justice #9320658 Technical Bid
Tender For Supply Of Goods And Installation Of Diffrent Item As Mentioned In Document In Tender Inviting Tender For Supply Of Goods And Installation Of Diffrent Item As Mentioned In Document In Tender , Kitchen Items , Aluminium Patila/Tapela With Lid(30 Litre Capacity Good Quality) , Aluminium Patila/Tapela With Lid(40 Litre Capacity Good Quality) , Iron Kadai With Handle (25 Litre Capacity) , Aluminium Kadai With Hndle (30 Litre Capacity) , Steel Parat (20 Kg Capacity) , Cooker ( 20 Ltr .Isi Mark) , Baati Oven(Large Size) Good Quality , Idli/Khaman Oven (Large Size) Good Quality , Steel Buckect With Handle ( 10 Ltr Thickness 0.65 M.M) , Steel Dhama (7 Ltr Thickness 0.91 M.M) , Iron Tawa (Heavy Quality Dia.500 Mm) , Steel Tapela (10 Ltr Heavy Quality) , Mortar And Pestle Set Iron (Height 140 Mm Tap Dia.130 Mm) , Katora Jalidar (15 Kg Ss Good Quality) , Chakla Belan , Masala Container Large (6 Section S.S. Spice Box) , Serving Spoon(Kadachi Ss Good Quality ) , Water Server Spoon (Ss Capecity 200 Ml) , Grain / Flour Sieve ( S.S. Good Quality) , Water Tank With Tap ( 20 Ltr S.S. Good Quality) , Flat Spoon /Tong/Knife/Forceps(Steel ) Best Quality , Thali (38 Cm .Ss Thickness 0.71 Mm) , Plate ( 20 Cm .Ss Thickness 0.71 Mm) , Bowl (12 Cm S.S. Good Quality) , Steel Glass (S.S. Good Quality) , Table Spoon (Ss Thickness 0.71 Mm) , Other Items , Mattress/Pillow/Sheet/Blanket( Mattress Size 6X3 Best Qulity Sheet/Blanket Size 54X90) , Gass Stove Double Bhatti( Heavy Material And Good Quality) , Gass Stove Single Bhatti( Heavy Material And Good Quality) , Gass Stove Roti Bhatti ( Heavy Material And Good Quality) , Gass Stove Domestic Gass Stove (3 Burner Heavy Material And Good Quality) , Grain Storage Container 50 Kg Capacity Ss Material Good Quality , Grain Storage Container 25 Kg Capacity Ss Material Good Quality , Grain Storage Container 10 Kg Capacity Ss Material Good Quality , Grain Storage Container 5 Kg Capacity Ss Material Good Quality , Cleaning Equipments , Broom Stick Best Quality , Wiper Best Quality , Phenyl Liquid 5 Litre , Dustbin Best Quality , Harpic 2 Litre , Hand Wash , Mob Best Quality , Toilet Brush Best Quality , Bathroom Floor Cleaning Brush Best Quality , Door & Bath Mats 3X2 Size , Plastic Bucketbest Quality , Plastic Bathroom Mug Best Quality , Furniture , Officer Table (6 X 3 With Drawer Two Side, Nova Pan Complite) , Officer Revolving (Chair Size 750X750x1050 Mm High Back) , Accountant Table (5X3 With Two Side, Drawar, Nova Pan Complit) , Revolving Chair (Size 750X750x1050 Mm High Back) , Visiting Chair( Size 500X550x820 Mm Good Material Sheet High 460) , Tea Table ( 4X2 With Glass Material) , Side Runner( Wooden Material With Box & Drawar) , Almirah (Size 1980X915x480 Mm., 0.80 Mm Sheet) , Mess Table/Bench(Table 1525X450x760 S.S. Top )Banch 1525X300x450 Fram Ms Pipe 25X25x1.25 , Visiting Bench( 3 Seater 1045X1175x650 Premium Modle) , Plastic Chair (With Hand Rest Heavy Material Good Quality) , Bed(1830X900x450 Mm Ms Pipe 30.00 Mm Angle Frem Water Proof Ply 12 Mm) , Kitchen Rack (1800X900x450 Mm , 0.80 Mm Sheet 5 Self) , Computer Table/Chair(1220X610x700 Mm Revolving Computer Chair Lowback) , Electronic Items , Cctv Surveillance System (2Mp, Ipcamera, With Dvr Installation And15 Days Backup Storage, 1 Year Warranty) , Led Smart Tv. (55 , With Setup Box, 3 Year Warnty, 3 Star, 3 Year Warranty) , Pa System (P A System With Amphlifier + Spcikar+Mic Capacity 100.00 Watt, 1 Year Warranty) , Desktop Computer (Intel I3 , 8 Gb Ram, 512 Ssd, 21.5 Monitor,10Th Gen,Windows 11,With Keyboard And Mouse, 3 Year Warranty) , Cooler (98 L Window Air Cooler With Honey Pad Trolly Support Motor Copper Binding, 1 Year Warranty) , Water Filter (Ro System/100 Liter/Hr Capacity 3 Year Warranty) , Watch (14 Size Ajanta) , Mixer Grinder( Isi. Mark 3 Jar 1 Year Warranty) , Refrigerater ( 275 Litter With Invertor, Double Door 3 Star Rating 5 Year Warranty) , Sport Items , Carrom Board (Full Size 32X32 Index With Wooden Carrommens Good Quality) , Chess Board (Wooden Foldable With Coins Good Quality) , Badminton Set Smash Xp 90 5 Racket (Set Fo 2+2 Full Cove) With Shuttle Bo Good Quality , Music Instruments , Harmonium (Sg Musical Ftgharl 31 3.25 Octave Hand Pumped Callibrated Good Quality) , Tabla (Hindustan Classical Percussion Tabla (Dayan 14 Cm, Bayan 22 Cm) Good Quality ) , Dhapli Good Quality , Dholak (Ram Musical 14 Baby Dholak Rmh-001 Nut & Bolt Dholak ) , Manjhira / Jhaanj Brass(Good Quality )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Madhya Pradesh View Result →
37.
Public Administrative Department #9310800 AOC
Tender For Furniture work at Pune Municipal Corporation building-ITEM NO: 1 Providing and fixing 19 mm thick waterproof plywood (durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI)) (SSR Item No: 62.12) (PMC Bhavan) Unique No (16543) Rate List Year (2024-2025) ITEM NO: 2 Providing and fixing 12 mm thick waterproof plywood (durian ucotech greenply, mars (marsgold 100% garjan), euro, orchid, century with phenol bonded etc (ISI)) (SSR Item No: 62.11) (PMC Bhavan) Unique No (16542) Rate List Year (2024-2025) ITEM NO: 3 Providing and fixing 12mm plain MDF sheet including all required material. (SSR Item No: 62.52) (PMC Bhavan) Unique No (16600) Rate List Year (2024-2025) ITEM NO: 4 Laminates sheets 1 mm thick: Providing and fixing laminates sheets as per company specification and fix it with fevicol Recommended companies- formica, Royal touch, Marino, Green lam, Euro. (1 mm thick laminates sheets) (SSR Item No: 62.23) (PMC Bhavan). Unique No (16566) Rate List Year (2024-2025) ITEM NO: 5 High Quality Veneer (Timex, Durian, Century/Green co. etc) completed (SSR Item No: 62.26) (PMC Bhavan) Unique No (16569) Rate List Year (2024-2025) ITEM NO: 6 Water base p u polish: Water base p u polish on old surface (SSR Item No: 62.47) (PMC Bhavan) Unique No (16595) Rate List Year (2024-2025) ITEM NO: 7 Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish, scaffolding if required etc. complete. Note: The work to be executed on prior approval of Superintending Engineer will be necessary. (SSR Item No: 34.09) (PMC Bhavan) Unique No (15549) Rate List Year (2024-2025) ITEM NO: 8 Providing,aupplying, fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face using stainless steel screws, nuts, bolts, washers, cleats, weather silicon sealent, backer rods etc .overall weight of the ACP shall not be less than 7.5 Kilogram/Square Metre) as specified (SSR Item No: 51.100) (PMC Bhavan) Unique No (16244) Rate List Year (2024-2025) ITEM NO: 9 Providing & fixing 1/2, 1/4to 1 tk Teakwood leaping patti including polishing etc completed. (SSR Item No: 62.27) (PMC Bhavan) Unique No (16570) Rate List Year (2024-2025) ITEM NO: 10 Providing & fixing plain glass of 4 mm thickness for window and wherever necessary as per dept. Instructions, it includes providing & using glezing clips, Putty of Kumbh Company etc. complete. (SSR Item No: 69.01) (PMC Bhavan) Unique No (17018) Rate List Year (2024-2025) ITEM NO: 11 Providing & fixing plain glass of 10 mm thickness for window and wherever necessary as per dept. instructions, it includes providing & using glezing clips, Putty of Kumbh Company etc. complete. (SSR Item No: 69.05) (PMC Bhavan) Unique No (17022) Rate List Year (2024-2025) ITEM NO: 12 Providing & fixing plain glass of 12 mm thickness for window and wherever necessary as per dept. instructions, it Includes providing & using glezing clips, Putty of Kumbh Company etc. complete. (SSR Item No: 69.06) (PMC Bhavan) Unique No (17023) Rate List Year (2024-2025) ITEM NO: 13 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (SSR Item No: 39.9) (PMC Bhavan) Unique No (15683) Rate List Year (2024-2025) ITEM NO: 14 Fiber Cushion Chairs Providing (ORNET MAKE) fiber cushion chairs of Supremo, Neelkamal brand. Note:-Cushion should be on both Seat & Backrest. (SSR Item No: 62.32) (PMC Bhavan) Unique No (16580) Rate List Year (2024-2025) ITEM NO: 15 C20 MESS CHAIR Visitor Chair, PP Arm, PP Frame Net Back, Seat GA 5022 Fabric Tapestry, Powder Coated Frame. The material shall be supplied from ISO 9001:2015, ISO 14001:2015, ISO 45001: 2018, BIFMA, AIOTA, GREENGUARD and approved by Consultant and Engineer in charge. Make of furniture: Godrej/Featherlite/Nilkamal & other similar type of manufacturing company. (SSR Item No: 62.84) (PMC Bhavan) Unique No (16626) Rate List Year (2024-2025) ITEM NO: 16 Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. (SSR Item No: 51.44) (PMC Bhavan) Unique No (16195) Rate List Year (2024-2025) ITEM NO: 17 C3 MB Supplying and placing ergonomically designed, comfortable & aesthetically appealing Medium back chair. The seat shall be made of 15mm thick hot pressed plywood with HR polyurethane foam 50mm thick having density 40kg/m³ upholstered with leatherite tapestry in light green colour with 0.8mm thick and 535 GSM and the back shall be made of double layered moulded hot pressed malaysian plywood (12+6)mm thick with HR polyurethane foam 40mm thick having density 32kg/m³ upholstered with leatherite in light green colour with 0.8mm thick and 535 GSM. Seat and back shall be Joined with HR steel shoot. The armrest shall be used PP arm completely joint with soat and back. The chair shall have swivel tilt revolving mochanism with single position locking and tilt tension adjustment. The prioumatio seat height adjustable 100mm with BIFMA standard class-3 gaslift. The Pedestal shall be made up of Injection moulded black nylon having pitch circle Dia 700 mm fitted with 5 nos, 50mm twin wheel castors which shall be made of injection moulded black nylon 30% glass filled having self lubricating property for friction free movemen with BIFMA standards. The Sent size shall be 485±10 mm(W)X485±10 mm(D) and back size shall be 555±10 mm(H) from seat & overall height 975±10 mm. The matorial shall be supplied from ISO 9001:2015, ISO 14001:2015, ISO 45001: 2018, BIFMA, AIOTA, GREENGUARD and approved by Consultant and Engineer In charge. Make of furniture: Godrej/Featherlite/Nilkamal & other similar type of manufacturing company. (SSR Item No: 62.115) (PMC Bhavan) Unique No (16657) Rate List Year (2024-2025) ITEM NO: 18 Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc. complete. (Sample to be final by Engineer In-charge prior execution of work) (SSR Item No: 51.19) (PMC Bhavan) Unique No (16170) Rate List Year (2024-2025) ITEM NO: 19 Curtains Providing clothes for curtain of Bombay Dyeing/Binni/Mafatlal etc brands, stitching as per required size with Frill (Zaller) & fixing at required places (Including rings) Note:-Measurement would be taken as per actual length of window& default width (l.e. 48 panha). Curtain (Material Synthetic Clothes & cost of clothes starting from Rmt Rs 250/-onwards) (SSR Item No: 62.30-B) (PMC Bhavan) Unique No (16577) Rate List Year (2024-2025) ITEM NO: 20 Providing and fixing in position. (as per I.S.1868/1982) Aluminium sliding window of two tracks with rectangular pipa having overall dimension 63.50 x 38.10 x 1.02 mm at weight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm at weight 0.695 Kilogram/Running metre. Top and side track section 61.85 x 31.75 x 1.30 mm at weight 0.659 Kilogram/Running metre. Tha shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre, Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre, and top section 40 x 18 x 1,25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass with all required screws and nuts etc, complete. With colour Anodising with box. (SSR Item No: 39.37) (PMC Bhavan) Unique No (15711) Rate List Year (2024-2025) ITEM NO: 21 Providing and fixing in line and level 8 mm thick laminated tila on existing tiled floor etc comleted (SSR Item No: 60.02-A) (PMC Bhavan) Unique No (16455) Rate List Year (2024-2025) ITEM NO: 22 PVC Carpet Providing 1.5 mm thick pvc carpet of approvad design n color & fixing at site as per site in charge Instructions etc. completed. Note: - Dimensions would be considered as per actual carpet size fixed at site. (SSR Item No: 62.33) (PMC Bhavan) Unique No (16581) Rate List Year (2024-2025) ITEM NO: 23 Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture spintone/cosmos/hexa or equivalent of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings, fixtures smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to celling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete. (currently this item should be used only for VIP cabins) (SSR Item No: 38.39) (PMC Bhavan) Unique No (15660) Rate List Year (2024-2025) ITEM NO: 24 Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 mm x 60 mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 128231990, laminated on both sides, Novateakor equivalent and 5 mm thick selected quality plain/float glass panels fixed with aluminum glass clips 12 mm x 12 mm and rubber cushioning beading to glass partitions as per approved drawing etc. compete (SSR Item No: 39.72) (PMC Bhavan) Unique No (15748) Rate List Year (2024-2025) ITEM NO: 25 Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.00 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm, 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick, vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc., I.S.I. mark, heavy duty, Hydraulic floor spring of 150Kilogramcapacity, having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam, pad handle, etc, as per detailed design and drawing or as directed by engineer in charge Including all materials, labours, and equipment etc. Complete (SSR Item No: 39.64) (PMC Bhavan) Unique No (15741) Rate List Year (2024-2025) ITEM NO: 26 Providing and fixing In position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications Including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick shoot glass louvers, of approved quality etc, complete, (SSR Item No: 39.68) (PMC Bhavan) Unique No (15744) Rate List Year (2024-2025) ITEM NO: 27 Providing and fixing acrylic plastic sheet panels of approved quality in required thickness plain clear or any colour or obscured linings in lieu of glass pans to doors/windows including providing and fixing clips, putty etc. complete. (b) 3.00 mm thick. (SSR Item No: 39.61) (PMC Bhavan) Unique No (15738) Rate List Year (2024-2025) ITEM NO: 28 Repairing of old sofa: As per engineer in charge instructions Meter repairing of old sofa using good quality company cloth ( Ddecor, Bombay dyeing, binni, mafatlal etc.) with appropriate density of foam, providing elastic, new wooden battens, also using good quality criss cotton as per requirements Including hardware fittings and labour rate (SSR Item No: 62.46) (PMC Bhavan) Unique No (16594) Rate List Year (2024-2025) ITEM NO: 29 Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms) Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat (SSR Item No: 51.53) (PMC Bhavan) Unique No (16203) Rate List Year (2024-2025) ITEM NO: 30 Providing & fixing all Furniture hardware as por site in charge Instructions Including all brass hardware fittings. (3 to 5sizes). Locks (For cupboards & wardrobes) (SSR Item No: 62.29-C) (PMC Bhavan) Unique No (16574) Rato List Year (2024-2025) ITEM NO: 31 Providing & fixing all Furniture hardware as per site in charge Instructions Including all brass hardware fittings. (3 to 5sizes) Hinges (SSR Item No: 62.29-A) (PMC Bhavan) Unique No (16572) Rate List Year (2024-2025) ITEM NO: 32 Providing & fixing all Furniture hardware as per site in charge instructions Including all brass hardware fittings. (3 to 5sizes). Handles (SSR Item No: 62.29-B) (PMC Bhavan) Unique No (10573) Rate List Year (2024-2025) ITEM NO: 33 Building (Bd-Q: Wood work) Tower Bolt brass oxidised 10 mm dia. Length 150 mm (SSR Item No: 49.Q-17) (PMC Bhavan) Unique No (17509) Rate List Year (2024-2025) ITEM NO: 34 Door Closure: (For 2 Hr fire Rated EN-3 Door Closure): Supplying fitting & fixing Surface mounted overhead Door Closer for 2 hour fire rated doors of different size (eg size -EN-3 for leaf width upto 900mm) CE certified, marked & conforming to EN 1154 of approved quality (Internationally reputed brand like Dorma, Geze. Hafele, Assabloy & Magnum etc.) fitted and fixed Complete as per direction & satisfaction of Engineer -In Charge including all taxes & incidental charges (SSR Item No: 51.J-176) (PMC Bhavan) Unique No (16273) Rate List Year (2024-2025) ITEM NO: 35 Building (Bd-T: Doors and windows) Mortico lock superior (SSR Item No: 49.T-34) (PMC Bhavan) Unique No (17604) Rate List Year (2024-2025) ITEM NO: 36 Providing and applying priming coat on concrete/ masonary/Asbestos Cement plastered surfaces including scaffolding If necessary, preparing the surface by thoroughly cleaning oll, grease, dirt and other foreign matter and sand papering as required etc. complete. (SSR Item No: 35.21) (PMC Bhavan) Unique No (15571) Rate List Year (2024-2025) ITEM NO: 37 Water bound distemper: Providing and applying water bound distemper along with primer coats including scaffolding if necessary, cleaning and preparing the surface etc. complete Recommended companies: Asian, neroleck, Dulex (SSR Item No: 63.1) (PMC Bhavan) Unique No (16691) Rate List Year (2024-2025) ITEM NO: 38 Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for périod 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9% with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) (SSR Item No: 36.20) (PMC Bhavan) Unique No (15594) Rate List Year (2024-2025) ITEM NO: 39 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer, will be necessary (SSR Item No: 35.26) (PMC Bhavan) Unique No (15576) Rate List Year (2024-2025) ITEM NO: 40 Providing and applying two coats of flat oil paint of approved colour and shade to internal / external plastered surfaces including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. (SSR Item No: 35.12) (PMC Bhavan) Unique No (15563) Rate List Year (2024-2025) ITEM NO: 41 Providing and laying Vitrified MATT finish having decorative type of size 600 millimeter x 600 millimeter of 8 to 10 millimeter thickness (on a existing flooring) with bonding chemical and confirming to IS 15622-2006 (Group Bla) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc.complete. (SSR Item No: 33.59) (PMC Bhavan) Unique No (15527) Rate List Year (2024-2025) ITEM NO: 42 Providing and laying full body vitrified mirror / glossy finish tiles having size 590 mm to 605mm to 1200 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for dado and skirting in required position with ready made adhesive mortar of approved quality including joint filling with white/cloured cement float filling joints, curing and cleaning etc. complete R.A. Unit: 1/ Square Metre (SSR Item No: 1.1) (PMC NON-DSR) Unique No (27062403) Rate List Year (2024-2025) ITEM NO: 43 Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etc. complete. (SSR Item No: 33.27) (PMC Bhavan) Unique No (15495) Rate List Year (2024-2025) ITEM NO: 44 Providing and laying matt finish ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. (SSR Item No: 33.24) (PMC Bhavan) Unique No (15492) Rate List Year (2024-2025) ITEM NO: 45 Providing and fixing of factory made Upvc casement window/Fixed Window & Casement Door(WhiteColour)comprising uPVC multi-chambered frame, Sash, & Mullion with wall thickness of 2.3mm(+-0.2mm), duly reinforced with G.I.section 1.5 mm UPVC window & door profile shall be made in India &shall conform to BSEN12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter1 Tensile Impact Strength ISO8256-morethan700Kj/m22Vicat Softening Temperature EN ISO-306 Shall not be < 750C3 Charpy Impact Strength EN ISO-179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO-178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN-514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS: 476 Part 7 Classification 18 Ignitability Evaluation BS: 476 Part 5 P Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All comers of frame and sash will be shall fusion welded.Mullion be welded/screwed.EPDM/TPEGasket shall be provided in all frame.sash&mullion, wherever necessary. Thereafter, 5mm Float Annealed glass shall be provided in the sash with the help of uPVC glazing bead and hardware,i.e., friction hinge&single point handle(inwindow) &3DHinges&Multi pointLock(indoor)shall be provided.Window/Door shall be fixed to the wall with 100mm long and 8mmdia.Fasteners and complete in all respect as per direction of Engineer-In-Charge.uPVC Window and Door Profiles are warranted for aperiod often (10) years against non-uniform discoloration, wrapping and rotting under general useA) Casement Window (BigSeries) frame of size 67x62mm & Sash/Mullion of size 67x78 mm. (SSR Item No: 54.09a) (PMC Bhavan) Unique No (16367) Rate List Year (2024-2025) ITEM NO: 46 Providing and laying telephone black / Amba White /Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. (SSR Item No: 33.68) (PMC Bhavan) Unique No (15533) Rate List Year (2024-2025) ITEM NO: 47 Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. Number: As directed by Engineer-in-charge. (SSR Item No: 23.07) (PMC Bhavan) Unique No (15303) Rate List Year (2024-2025) ITEM NO: 48 Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. (SSR Item No: 27.01) (PMC Bhavan) Unique No (15370) Rate List Year (2024-2025) ITEM NO: 49 Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. (SSR Item No: 32.08) (PMC Bhavan) Unique No (15443) Rate List Year (2024-2025) ITEM NO: 50 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions Including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (SSR Item No: 32.11) (PMC Bhavan) Unique No (15444) Rate List Year (2024-2025) ITEM NO: 51 Heritage look premium Mosaic, Terrazzo flooring: Providing and laying heritage look premium Mosaic, Terrazzo flooring 18mm to 20mm thick and of required width in plain/diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc complete. (SSR Item No: 67.26) (PMC Bhavan) Unique No (16940) Rate List Year (2024-2025) eyc
Contract Date: Feb 05, 2026 Contract Value : 50.75 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
40.
Drinking Water Supply and Sanitation #9084158 Technical Bid
Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Dumri Panchayat Chachando Village Jobhi Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2022-23 Svs 79 , Model-1B With Source (Drilled T/W 125/115Dia Mm, 60M Deep) , Tube Well , Drilling Portion , Construction For 115/125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125/115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , (A) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , (B) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E/I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi/Ci Cap 125 Mm Dia T/W Properly All Complete And Taking It Out As Per Specification & Direction Of E/I. (The Cap Will Be Property Of Department) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. (Medium)Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E/I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc (1:2:4) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster (1:4) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc (1:2:4) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T/Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T/W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet/Format All Complete As Per Direction Of E/I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 (Part 2) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe (Medium) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239(Part 1990). , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818/2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M ,Including All Lifts, Levelling ,Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design ,Building Specification And Direction Of E/I(Vide Classification Of Soil Item -B) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials ,Labour ,Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I , Back Filling , Providing Nominal Mix Pcc Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Rcc M-20 In Nominal Mix Of (1:1.5:3) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I. , (A)Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , (B)Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , (A) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , (Cement+Rod) Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing ,Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge ,Including Cutting Fabricating ,Hoisting , Erecting And Fixing In Position , Making Riveted/Bolted /Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure(Plus) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns (Net Wt. Of Components To Be Galv) Preferably Tata Structural Section Etc Complete. , Hardware (L.S.) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Carrying Out Recuperation/Yield Test For Ascertaining The Discharge Of Constructed Well/ Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well/ Profile Below Normal/Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level/Subsoil Water Level In The Well / Profile As Well As Strainer/Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T/W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E/I. (As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm (12) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil (Vide Classification Of Soil Item-A) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E/I. , Providing Pcc M-150 In Nominal Mix Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples (But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts) All Complete As Per Specification And Direction Of E/I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E/I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E/I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg/Sqm , Cost Of 50 X 50 X 6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
41.
Banking and Finance #9079750 Technical Bid
E-Tender For Procurement Of Equipment For Manodaya, Jatni Composite Centre For Cognitive Disability ( Adults ) At Iic Jatni, Khordha District Under Siep E-Tender For Procurement Of Equipment For Manodaya, Jatni ( Composite Centre For Cognitive Disability ( Adults ) At Iic Jatni, Khordha District Under Siep , Section-I- Equipment For Therapy Unit , Treadmill- 4Hp Noiseless Ac Motor , Bolsters Of Different Sizes , Puzzle – Body Parts With Two Facial Expressions With Box, Animal, Birds, Fruits, Transports, Different Shapes , Lower Extremity Cpm , Cp Chair , Static Cycle , Reclined Cycle , Height Scale , Texture Fruit Tree , Ball Pool ( 48”X 48” ) , Perdue Peg Board- Large, Medium & Small , Exercise Mats – 6’X3’ , Exercise Frame – Rope Mess, Pip Ladder And Rock Climbing Board , Trampoline ( 48 Inch ) With Mess Covering , Quadriceps Table With Detachable Backrest , Stethoscope , Blood Pressure Apparatus , Goniometer – 180 & 360 Degree , Electronic Stopwatch , Digital Weighting Machine , Treatment Trolley , Muscle Stimulator Combo- With Current -Galvanic, Interrupted Galvanic, Faradic, Surged Faradic And Tens , Weight Cuff- 1 / 4 Kg, 1 / 2 Kg, 1 Kg, 1.5 Kg , Thera Band- Different Colours And Ranges , Thera Putty Withdifferent Colours & Ranges , Portable Shoulder Exerciser With Pronation Supination Arrangement , Grip Exerciser , Hand Gym Kit Board , Wrist Roll , Rope Pulley Handle Set , Upper Extremity Work Station , Vestibulator With Facility Of Platform Swing, Flexion Disc, Frog Swing, Lycra Swing , Bolster Swing Rectangular , Vestibular Board – 3’.6” X 2’.6” X 7 , Scooter Board , Wedges Of Different Sizes , Post Box With 25 Plates , Door Latch Board , Floor Seater , Stand In Table With Standing Metal Frame Of Size- L, M & S , Tunnel , Treatment Plinth , Wooden Blocks Of Different Heights- Set Of 6 , Peanut Ball , Staircase , Parallel Bars With Platform , Suspension Frame , Stability Disc , Ramp And Curb , Balls For Ball Pool , Ankle Exerciser , Walker With 4 Castors – Non Folding Posterior Opening , Walker Without Castors – Non Folding Posterior Opening , Circle Balance Disc , Board For Lower Extremity – Standing Exercise , Foot Placement Ladder , Graded Spring Set , Long Handle Thick Grip Spoons, Combs, Brushes , Tactile Balls For Grip , Lotca Battery Test , Minnesota Test , Tilt Table , Wobble Board , Cryo Therapy Unit , Treatment Couch , Children Medical Cycle – Corival Pediatric Ergometer Cycle , Ultrasound- 1 And 3 Mhz Frequency – Us-751 , Medicine Ball Of Size- 1 Kg, 2Kg, 4Kg , Therapy Ball Of Size-75Cm, 90Cm & 125Cm , Reverse Walker- Anterior Opening With Back Seat , Finger Ladder , Mirror- 3’ X 3’ , Nirmal Hand Apparatus , Whirlpool Bath , Hydrocollator Unit , Mini Hydrotherapy Unit , Sensory Brushes , Rocking Horse , Inclined Stand Table , Torch Light , Gait Ladder , Gaiters Of All Sizes , Elbow Crutches , Rolator Walkers , Walking Frames-Child , Section-Ii- Equipment For Audiology & Speech Therapy Unit , Single Portable Unit -Pure Tone Audiometerwith Facilities Of Free Field Audiometry & Speech Audiometry And Lithium-Ion Battery Backup , Impedance Audio-Meter With Tympanometry Mode Touch Screenand Built In Thermal Printer - Table Top Model , Oto- Acoustic Emission ( Oae ) Instrument- Dual Channel Diagnostic Audiometer With Tdh-39 Earphones And Radio Ear B71 Bone Transducer , Non-Sedated Diagnostic Bera With 2 Channel And Vemp, Abr & Ssr Facilities And Computer Accessibility Through Usb Portal , Examination Bed With Mattress And Oil Cloth To Carry Out Bera Test , Video Oto-Scope With Computer Accessibility , Acoustic Booth 15’X12’X 7’ With Inner Partition, Double Door, Magnetic Seal, Silenced Ventilation With Observation Window , Visi-Pitch With All Accessories & Dr. Speech Software , Bio Feedback System For Stammering Therapy With All Accessories / Metronome , Speech Therapy Materials ( Local Purchase ) With Mirror- 4’ X 3’ , Mattress 6’ X 6’ , Small Chairs Of Height 1’ And Back Support , Tongue Depressor , Portable Impedance Audio-Meter With Tympanometry Mode Touch Screenand Built In Thermal Printer , Noise Level Meter , Hipro-2 For Programming Of Digitalh.Aids , Trial Digital Programmable Bte / Itc Hearing Aids , Section-Iii- Equipment For Psychology & Psychotherapy Unit , A ) Intelligence Test , Vsms ( Vineland Social Maturity Scale ) , Sfb ( Seguin Form Board Test ) With Manual & Answer Sheets , Bkt ( Binet Kamat Intelligence Test ) , Misic ( Malin’S Indian Scale For Intelligence ) , Wais ( Wechler’S Adult Intelligence Scale ) , Cpm ( Coloured Progressive Matrix ) , Bhatia Intelligence Test , Bharatraj Developmental Screening Test , Denver’S Intelligence Test , Standard Progressive Matrix , B ) Personality & Psycho-Diagnostic , Rorschach Ink Blot Test , Thematic Apperception Test ( Tat ) , Children Apperception Test ( Cat-Animal Cards ) , 16 Personality Factor Inventory , Mmpi , C ) Cognitive Function Test , Wcst ( Wiscomin’S Card Sorting Test ) , Bgt ( Bender Gestast Test ) , Bvrt ( Bender Visual Retention Test ) , Stroop Test , Tmt ( Trail Making Test ) , D ) Neuro-Psychological Battery , Pgi- Bbd , Aiims Neuro Psychological Battery , E ) Behavioural Symptom Analysis , Child Behaviour Check List ( Cbcl ) , Bayley’S Developmental Assessment ( Dst ) , F ) Scales , Bdi , Hamilton Depression Rating Scale ( Ham-D ) , Brief Psychiatric Rating Scale ( Bprs ) , Adhd Cormor’S Rating Scale ( Adhd-Crs ) , Adhd Vanderbilt Rating Scale ( Adhd-Vrs ) , Asd- Cars-2 , Asd- Isaa , Asd- Inclean , Conduct Disorder Scale ( Cds ) , Suicidal Ideation Questionnaire ( Siq ) , G ) Sld , Diagnostic Test Of Learning Disability ( Dtld ) , Diagnostic Test Of Reading Disorder ( Dtrd ) , Nimhans Sld Battery , Bio Feed Back & Neuro Feed Back , Section-Iv- Play & Recreational Therapy Unit , Misc. Items For Play & Recreational Therapy Like Sand Pit, Mud Pit, Tyre Rows & Other Local And Low Cost Items For Cognitive & Sensory Development , Section-V- Skill Development & Craft Training Unit , Misc. Tools, Equipment &Items For Skill Development, Craft Training And Sheltered Workshop , Annual Comprehensive Maintenance Charges ( Please Quote The Rate Per For 5 Years ) , Section-I , Section-Ii , Section-Iii , Section-Iv , Section-V
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
42.
Banking and Finance #9079742 Technical Bid
E-Tender For Procurement Of Equipment For Hub And Spoke Centres At Mayurbhanj And Keonjhar Districts Of Odisha E-Tender For Procurement Of Equipment For Hub And Spoke Centres At Mayurbhanj And Keonjhar Districts Of Odisha , Section-I- Equipment For Physio-Occupational Therapy Unit , Treadmill- 2Hp Noiseless Ac Motor , Short Wave Diathermy- 500W With Valve , Bolsters Of Different Sizes , Puzzle – Body Parts With Two Facial Expressions With Box, Animal, Birds, Fruits, Transports, Different Shapes , Shoulder Cpm , Lower Extremity Cpm , Cp Chair , Static Cycle , Bed Cycle , Weighing Scale , Texture Fruit Tree , Ball Pool (48”X 48”) , Perdue Peg Board , Exercise Mats – 6’X3’ , Exercise Frame – Rope Mess, Pip Ladder And Rock Climbing Board , Trampoline (48 Inch) , Quadriceps Table With Detachable Backrest , Stethoscope , Blood Pressure Appratus , Goniometer – 180 & 360 Degree , Electronic Stopwatch , Digital Weighting Machine , Treatment Trolley , Muscle Stimulator Combo- With Current -Galvanic, Interrupted Galvanic, Faradic, Surged Faradic And Tens , Micro Control 4 Channel Tens , Weight Cuff- 1/4 Kg, 1/2 Kg, 1 Kg, 1.5 Kg , Thera Band- Different Colors And Ranges , Thera Putty Withdifferent Colors & Ranges , Portable Shoulder Exerciser With Pronation Supination Arrangement , Grip Exerciser , Hand Gym Kit Board , Wrist Roll , Rope Pulley Handle Set , Upper Extremity Work Station , Vestibulator With Facility Of Platform Swing, Flexion Disc, Frog Swing, Lycra Swing , Bolster Swing Rectangular , Vestibular Board – 3’.6” X 2’.6” X 7 , Scooter Board , Wedges Of Different Sizes , Post Box With 25 Plates , Door Latch Board , Floor Seater , Stand In Table With Standing Metal Frame Of Size- L, M & S , Tunnel , Treatment Plinth , Wooden Blocks Of Different Heights- Set Of 6 , Peanut Ball , Staircase , Parallel Bars With Platform , Suspension Frame , Stability Disc , Ramp And Curb , Balls For Ball Pool , Ankle Exerciser , Walker With 4 Castors – Non Folding , Walker Without Castors – Non Folding , Circle Balance Disc , Board For Lower Extremity – Standing Exercise , Foot Placement Ladder , Graded Spring Set , Long Handle Thick Grip Spoons , Tactile Balls For Grip , Lotca Battery Test , Minnesota Test , Exercise Frame – Rope Mess, Pip Ladder And Rock Climbing Board , Tilt Table , Wobble Board , Cryo Therapy Unit – Cryotherm Ht – E12500 , Treatment Couch , Pain Relief System Hm-202 , Children Medical Cycle – Corival Pediatric Ergometer Cycle , Ultrasound- 1 And 3 Mhz Frequency – Us-751 , Medicine Ball Of Size- 1 Kg, 2Kg, 4Kg , Therapy Ball Of Size-75Cm, 90Cm & 125Cm , Reverse Walker , Finger Ladder , Mirror- 3’ X 3’ , Section-Ii- Equipment For Audiology & Speech Therapy Unit , Single Portable Unit -Pure Tone Audiometerwith Facilities Of Free Field Audiometry & Speech Audiometry , Impedance Audiometer , Oto Acoustic Emission (Oae) Instrument- Dual Channel Diagnostic Audiometer With Tdh-39 Earphones And Radio Ear B71 Bone Transducer , Non-Sedated Diagnostic Bera With 2 Channel And Vemp, Abr & Ssr Facilities And Computer Accessibility Through Usb Portal , Examination Bed With Mattress And Oil Cloth To Carry Out Bera Test , Video Oto-Scope With Computer Accessibility , Acoustic Booth 15’X12’X 7’ With Inner Partition, Double Door, Magnetic Seal, Silenced Ventilation With Observation Window , Visi-Pitch With All Accessories & Dr. Speech Software , Bio Feedback System For Stammering Therapy With All Accessories/Metronome , Speech Therapy Materials (Local Purchase) With Mirror- 4’ X 3’ , Mattress 6’ X 6’ , Small Chairs Of Height 1’ And Back Support , Tongue Depressor , Section-Iii- Equipment For Psychology Unit , A) Intelligence Test , Vsms (Vineland Social Maturity Scale) , Sfb (Seguin Form Board Test) With Manual & Answer Sheets , Bkt (Binet Kamat Intelligence Test) , Misic (Malin’S Indian Scale For Intelligence) , Wais (Wechler’S Adult Intelligence Scale) , Cpm (Coloured Progressive Matrix) , B) Personality & Psycho-Diagnostic , Rorschach Ink Blot Test , Thematic Apperception Test (Tat) , Children Apperception Test (Cat-Animal Cards) , 16 Personality Factor Inventory , C) Cognitive Function Test , Wcst (Wiscomin’S Card Sorting Test) , Bgt (Bender Gestast Test) , Bvrt (Bender Visual Retention Test) , Stroop Test , Tmt (Trail Making Test) , D) Neuro-Psychological Battery , Pgi- Bbd , E) Developmental Screening Tools Behavioural Symptom Analysis , Gessel’S Developmental Scale , Bayley’S Developmental Assessment (Dst) , F) Scales , Bdi , Hamilton Depression Rating Scale (Ham-D) , Brief Psychiatric Rating Scale (Bprs) , Adhd Cormor’S Rating Scale (Adhd-Crs) , Adhd Vanderbilt Rating Scale (Adhd-Vrs) , Asd- Cars-2 , Asd- Isaa , Asd- Inclean , Child Behaviour Checklist (Cbcl) , Conduct Disorder Scale (Cds) , G) Sld , Diagnostic Test Of Learning Disability (Dtld) , Diagnostic Test Of Reading Disorder (Dtrd) , Section-Iv- Play & Recreational Therapy Unit , Misc. Items For Play & Recreational Therapy Like Sand Pit, Mud Pit, Tyre Rows & Other Local And Low Cost Items For Cognitive & Sensory Development , Annual Comprehensive Maintenance Charges (Please Quote The Rate Per For 5 Years) , Section-I , Section-Ii , Section-Iii , Section-Iv
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
43.
Educational and Research Institute #9077081 Technical Bid
Tender For Replacement Of Equipments Installed In Kitchen Mess At Nipgr
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
44.
Drinking Water Supply and Sanitation #9062077 Technical Bid
Construction Of Solar Based Mrwss Svs In Pirtand Block, Comprising Of Suitable R.C.C Framed Structure Esr Distribution Lines, Source ( As Required ) And Fhtc All Complete Under Drinking Water Sanitation Division No 2 Giridih Cluster No 13 , Model-1Awith Source ( Drilled T / W 125 / 115 Dia Mm, 60M Deep ) , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Fitting, Fixing & Mounting On Water Tank Steel Structure. , Xvi ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. , Provision Of Solar Night Lamp. , Construction Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I ( Mode Of Measurement Compacted Volume ) , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-200 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing , Vertical Pedestal , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , 10 Mm Dia , 12 Mm Dia , Carriage Of Construction Materials To Work Site Including Loading, Unloading & Stacking Etc. All Complete. , Cement10km Lead , Steel10km Lead , Stone Chips 11Km Lead , Sand36km Lead , Bricks 06Km Lead , Construction Ofgalvanized Tubular Steel Structure Staging For ( 4.5M ) Hdpe Water Storage Tank& Solar Panel. , Providing Structural Steel Galvanised Tubular Hollow Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete. , Materials And Labour For Vinyl Painting Of Matter Given By Department In Different Color , Installation Of 2000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 2000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 2000 Litrs Capacity Tank Up To 4.5M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 10 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution Main , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe- , 20 Mm Hdpe Pipe- , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65 Mm Dia , 50 Mm Dia . , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , For Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , 15 Mm Dia Gi Pipe , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. , Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year , O & M Cost For 2Nd Year , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model-1B With Source ( Drilled T / W 125 / 115Dia Mm, 60M Deep ) , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65 Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X 50 X 6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
45.
Drinking Water Supply and Sanitation #9062066 Technical Bid
Construction Of Solar Based Mrwss Svs In Pirtand Block, Comprising Of Suitable R.C.C Framed Structure Esr Distribution Lines, Source ( As Required ) And Fhtc All Complete Under Drinking Water Sanitation Division No 2 Giridih Cluster No 22 , Model-1Awith Source ( Drilled T / W 125 / 115 Dia Mm, 60M Deep ) , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Fitting, Fixing & Mounting On Water Tank Steel Structure. , Xvi ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. , Provision Of Solar Night Lamp. , Construction Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I ( Mode Of Measurement Compacted Volume ) , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-200 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing , Vertical Pedestal , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , 10 Mm Dia , 12 Mm Dia , Carriage Of Construction Materials To Work Site Including Loading, Unloading & Stacking Etc. All Complete. , Cement10km Lead , Steel10km Lead , Stone Chips 11Km Lead , Sand36km Lead , Bricks 06Km Lead , Construction Ofgalvanized Tubular Steel Structure Staging For ( 4.5M ) Hdpe Water Storage Tank& Solar Panel. , Providing Structural Steel Galvanised Tubular Hollow Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete. , Materials And Labour For Vinyl Painting Of Matter Given By Department In Different Color , Installation Of 2000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 2000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 2000 Litrs Capacity Tank Up To 4.5M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 10 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution Main , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe- , 20 Mm Hdpe Pipe- , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65 Mm Dia , 50 Mm Dia . , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , For Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , 15 Mm Dia Gi Pipe , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. , Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year , O & M Cost For 2Nd Year , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model-1B With Source ( Drilled T / W 125 / 115Dia Mm, 60M Deep ) , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65 Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Bricks Lead 06 Km ( Avg. ) , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X 50 X 6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 10 Km ( Avg. ) , Sand Lead 36 Km ( Avg. ) , Stone Chips Lead 11 Km ( Avg. ) , Steel Reinforcement Lead 10 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
46.
Drinking Water Supply and Sanitation #9062055 Technical Bid
Const Of Solar Based Mrwss Svs In Pirtand Block, Comprising Of Suitable R.C.C Framed Structure Esr Distribution Lines, Source (As Required) And Fhtc All Complete Under Drinking Water Sanitation Division No 2 Giridih Cluster No 37 , Model-1Awith Source(Drilled T/W 125/115 Dia Mm, 60M Deep) , Tube Well , Drilling Portion , Construction For 115/125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125/115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , (A) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , (B) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E/I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi/Ci Cap 125 Mm Dia T/W Properly All Complete And Taking It Out As Per Specification & Direction Of E/I. (The Cap Will Be Property Of Department) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. (Medium)Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E/I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc (1:2:4) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster (1:4) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc (1:2:4) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T/Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T/W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet/Format All Complete As Per Direction Of E/I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 (Part 2) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe (Medium) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239(Part 1990). , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818/2016 Cml No.- 5543459 , Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Fitting, Fixing & Mounting On Water Tank Steel Structure. , Xvi) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Carrying Out Recuperation/Yield Test For Ascertaining The Discharge Of Constructed Well/ Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well/ Profile Below Normal/Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level/Subsoil Water Level In The Well / Profile As Well As Strainer/Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T/W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E/I. , Provision Of Solar Night Lamp. , Construction Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M ,Including All Lifts, Levelling ,Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design ,Building Specification And Direction Of E/I (Vide Classification Of Soil Item -B) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials ,Labour ,Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I(Mode Of Measurement Compacted Volume) , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Pcc M-150 In Nominal Mix Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Rcc M-200 In Nominal Mix Of (1:1.5:3) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I. , (A)Foundation For Steel Structure Staging , Footing , Vertical Pedestal , Tie Beam , (B)Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , 10 Mm Dia , 12 Mm Dia , Carriage Of Construction Materials To Work Site Including Loading, Unloading & Stacking Etc. All Complete. , Cement10km Lead , Steel10km Lead , Stone Chips 11Km Lead , Sand36km Lead , Bricks 06Km Lead , Construction Ofgalvanized Tubular Steel Structure Staging For (4.5M) Hdpe Water Storage Tank& Solar Panel. , Providing Structural Steel Galvanised Tubular Hollow Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing ,Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge ,Including Cutting Fabricating ,Hoisting , Erecting And Fixing In Position , Making Riveted/Bolted /Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure(Plus) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns (Net Wt. Of Components To Be Galv) Preferably Tata Structural Section Etc Complete. , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete. , Materials And Labour For Vinyl Painting Of Matter Given By Department In Different Color , Installation Of 2000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 2000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 2000 Litrs Capacity Tank Up To 4.5M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 10 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. For Construction Of Road Cutting Portion. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution Main , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe- , 20 Mm Hdpe Pipe- , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia , 50 Mm Dia . , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , For Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , 15 Mm Dia Gi Pipe , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. , Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year , O & M Cost For 2Nd Year , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model-1B With Source (Drilled T/W 125/115Dia Mm, 60M Deep) , Tube Well , Drilling Portion , Construction For 115/125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125/115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , (A) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , (B) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E/I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi/Ci Cap 125 Mm Dia T/W Properly All Complete And Taking It Out As Per Specification & Direction Of E/I. (The Cap Will Be Property Of Department) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. (Medium)Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E/I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E/I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc (1:2:4) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster (1:4) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc (1:2:4) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T/Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T/W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet/Format All Complete As Per Direction Of E/I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 (Part 2) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe (Medium) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239(Part 1990). , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818/2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M ,Including All Lifts, Levelling ,Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design ,Building Specification And Direction Of E/I(Vide Classification Of Soil Item -B) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials ,Labour ,Royalty And Taxes All Complete As Per Building Specification And Direction Of E/I , Back Filling , Providing Nominal Mix Pcc Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I , Providing Rcc M-20 In Nominal Mix Of (1:1.5:3) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E/I. , (A)Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , (B)Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , (A) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing ,Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge ,Including Cutting Fabricating ,Hoisting , Erecting And Fixing In Position , Making Riveted/Bolted /Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure(Plus) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns (Net Wt. Of Components To Be Galv) Preferably Tata Structural Section Etc Complete. , Hardware (L.S.) , Information Board For Iec , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 50 Mm Hdpe Pipe , 65 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Carrying Out Recuperation/Yield Test For Ascertaining The Discharge Of Constructed Well/ Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well/ Profile Below Normal/Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level/Subsoil Water Level In The Well / Profile As Well As Strainer/Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T/W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E/I. (As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm (12) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil (Vide Classification Of Soil Item-A) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E/I. , Providing Pcc M-150 In Nominal Mix Of (1:2:4) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples (But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts) All Complete As Per Specification And Direction Of E/I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E/I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E/I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg/Sqm , Cost Of 50 X 50 X 6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model- 02 (8000 Litre 8 Meter Staging) , Construction Of 125 Mm X 115 Mm X 90.0 M Deep Drilled Tube Well , Supplying All Materials, Labour And Tools And Equipment For Drilling 125 X 115 Mm Dia Bore Well In Any Kinds Of Soil And Rocks By Using D.T.H. Super Rig Machine And Ball Hammer Technology Including All Technology Inclusive Of Mobilization, Demobilization Of Rigs Air Compressor All Accessories Of Rigs Tools And Plant Labour Etc. All Complete Job Including Transportation Charge Cost Of Flushing Charge, Geographical Investigation Etc. All Complete , (A) 0.00M Up To 30.00M Depth Below G.L. In Rural Areas , (B) 30.000M Up To 120.00M Depth Beyond . In Rural Areas , Basic Rate Of 125Mmdia Blue Upvc Casingpipe Confirming To I.S.I . Latest Revision Is(12818)/2016 , Supplying All Materials, Labour And Inserting Upvc Bluepipe 125 Mm Internal Dia Casing Pipe For Protecting The Bore Hole In Over Burden Up To Hard Surface As Per Is 12818-1392 With Latest Revision All Complete Job With Taxesas Per Specification And Direction Of E/I. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipment’S For Grouting Casing Pipe , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying Laboursand Equipment’S Including 125 Mm Dia G.I. Cap & Fittingand Fixing Over Thecasing Pipe Of Bore Well Properly And Taking It Out As Per Direction Of E/I. , Supplyingmaterials And Labours For Constructing Bore Well Chamber Of 75 B Designation Brick Masonry Chamber 600 Mm X 450 Mm And 750 Mm Deep Internal Dimension Having 250Mm Thickness In Cement Mortar 1:6 Including 12Mm Cement Plaster 1:6 With 600 Mm X 475 Mm Rcc Cover With Earth Work In Excavation And 75 Mm Thick Pcc (1:3:6) In Foundation And Refilling All Complete As Per Specification And Direction Of E/I. , 2 H.P. D.C. Solarmotor Pump Complete Set , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Ecofriendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 2 Hp (Dc Pump) With 1800 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 100 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Provision Of Solar Night Lamp. , 8000 Litre Capacityr.C.C. Water Tank (2.1 X 2.1 X 2.1 M Internal Size) With 8 M Staging Having Utility Room At Ground Level , Earth Work In Excavation In Foundation Trenches In Ordinary Soil (Vide Classification Of Soil Item-B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 M Including All Lifts,Levelling,Ramming The Foundation Trenches, Removing Roots Of Trees Shrubs All Complete As Per Approved Design, Building Specification And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening, Mixing Cement Concrete In Mixer And Placing In Position,Vibrating,Curing,Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Providing And Laying In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal For Rcc Work In Foundation Like Raft, Grillage, Strip Foundation And Footing Of Rcc Columns And Steel Stanchions Including Normal Dewatering, Plywood Form Work, Bully/Steel Propups, Compaction, Finishing Andcuring, Etc, Complete. (By Weigh Batching And Mix Design For M-250Only. Use Of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted.) , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only.Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , G.L To Above Roof Of Utility Room , Column Utility Room, Roof Beam To Tank Beam M-25 , Column Tank Beam To Tank Roof M-25 , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Bracing , Beam Of Tank Floor , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) (Excluding M.S, Or Tor Reinforcement) For Rcc M-300 Grade Slabs / Landings / Vertical Walls Section-G-Plain And Reinforced Cement Concrete , Tank Floor Roof M-30 , Tank Roof Top M-25 , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads Including Cost Of Materials,Labours,Royalityand Taxes All Complete As Per Building Specification And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Filling In Foundation Trenches And Plinth In Layers Not Exceeding 150Mm Thick, Well Watered,Rammed,Fully Compacted And Fine Dressed With Earth Obtained From Excavation Of Foundation Trenches Within A Lead Of 50M And Lift Of 1.5M All Complete As Per Building Specifications And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 75 A Brick Work In C.M(1:6) In Foundation And Plinth With Approved Quality Of Clean Coarse Sand Of F.M.2 To2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints To 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In C.M(1:6) In Superstructure With Approved Quality Of Clean Coarse Sand Of F.M 2 To 2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Bldg. Specification And Direction Of E/I. , Providing R.C.C.M-200 In Nominal Mix Of (1:1.5:3) In Lintel With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Of F.M 2.5 To 3 Including Screening, Centering, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating Striking, Curing(But Excluding The Cost Of Reinforcement),Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Av.63 Mm Thick R.C.C M-200 In Nominal Mix Of (1:1.5:3) Chhajja With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including In Mixer And Placing In Position,Vibrating,Striking,6Mm Cement Plaster(1:4) In Ceiling And Sides Of Chhajja With Sand Of F.M 1.5, Curing(But Excluding The Cost Of Reinforcement) Taxes, And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing T.M.T Steel Reinforcement Of Different Dia Rods As Per Approved Design And Drawing Including Carriage Of M.S Bars To Work Site, Cutting Bending And Binding With Annealed Wire With Cost Of Wire, Removal Of Rust, Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing M.S Grill Made Of 20*6 Mmm.S Flats As Per Approved Design And Drawing, Properly Fabricated With Joints Continuous Fillet Welded And Finished Smooth, Carriage Of Grill To Work Site, Hoisting As Per Building Specification And Direction Of E/I. , Providing And Fixing Fan Hooks Of 16 Mm Dia M.S.Bar & 1 Meter Long Bent To Required Size And Shape, Placed In Position And Fixed In The R.C.C. Slab/Beam At The Time Ofcasting All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing 20 Gauge G.C.I Sheet Gate Fitted On M.S Angle Frame Of Size60*60*6 Mm Including Cost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In C/C(1:2:4) Blocks Of Required Size, Applying A Priming Red Lead Paint Over Steel Work, Taxes All Complete As Per Drawing Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:4) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:6) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 6 Mm Cement Plaster (1:4 ) In Ceiling With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With Floating Coat Of Neat Cement In Skirting Including Rounding Of Junctions With Floor,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 19 Mm Water Proof Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With 5% Cico Or Any Other Approved Water Proofing Compound Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 1.5 Mm Cement Punning Including Curing, Carriage Of Water With All Leads And Lifts As Per Building Specification And Direction Of E/I. , Providing Two Coats Of Snowcem Of Approved Shade And Make Over Old Surface Including Washing, Cleaning, Sand Papering The Wall,Scaffolding,Curing And Taxes All Complete As Per Building Specification & Direction Of E/I. , Extra For Each Coat Of Cement Wash, Distemper Paint Or Snowcem Over Exterior Surface For Each Consecutive Floor Above First Floor Including Scaffolding Etc All Complete As Per Building Specification & Direction Of E/I. , Providing Two Coats Of Synthetic Enamel Paint Of Approved Shade And Make Over Steel Surface Throughly,Scaffolding And Taxes All Papering Including Cost Of Scaffolding And Taxes All Complete As Per Building Specification & Direction Of E/I. , Providing And Fixing G.I. Pipe Railing Having 1.0 M Height Consisting 50 X 50 X 6 Mm Thick M. S. Angles As Verticals At 1.5 M C/C, And Additional Posts At Every Corner With 3 Rows Of 25 Mm Dia G.I. Pipes Of Medium Class Variety As Horizontal And Painting 3 Coats Of Oil Paint Over 1 Coat Of Anticorrosive Paint Of Approved Colour And Shade Including Cost Of All Labour, Transporting Bends To Curved Shape, Etc. Complete. , Providing And Fixing In Position M.S. Ladder 0.50 M Wide Consisting Of 75 X 10 Mm M.S. Flats As Stringers And 16 Mm Dia M.S. Bars In Double Rows As Steps Placed At 25 Cm C/C Including Cost Of Material And Labour Involved, Welding, Anchoring And Applying 3 Coat Of Anti-Corrosive Paint, Etc. Complete As Directed By Engineer-In-Charge. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Distribution Network & House Connection20 -40 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia. , 50 Mm Dia. , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc (01 Sim Each Year) , Model- 03 (12000 Litre 10 M Staging) , Construction Of 125 Mm X 115 Mm X 90.0 M Deep Drilled Tube Well (2 Nos Of Dt) , Supplying All Materials, Labour And Tools And Equipment For Drilling 125 X 115 Mm Dia Bore Well In Any Kinds Of Soil And Rocks By Using D.T.H. Super Rig Machine And Ball Hammer Technology Including All Technology Inclusive Of Mobilization, Demobilization Of Rigs Air Compressor All Accessories Of Rigs Tools And Plant Labour Etc. All Complete Job Including Transportation Charge Cost Of Flushing Charge, Geographical Investigation Etc. All Complete , (A) 0.00M Up To 30.00M Depth Below G.L. In Rural Areas , (B) 30.000M Up To 120.00M Depth Beyond . In Rural Areas , Basic Rate Of 125Mmdia Blue Upvc Casingpipe Confirming To I.S.I . Latest Revision Is(12818)/2016 , Supplying All Materials, Labour And Inserting Upvc Bluepipe 125 Mm Internal Dia Casing Pipe For Protecting The Bore Hole In Over Burden Up To Hard Surface As Per Is 12818-1392 With Latest Revisionall Complete Job With Taxesas Per Specification And Direction Of E/I. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipment’S For Grouting Casing Pipe , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E/I. , Supplying Laboursand Equipment’S Including 125Mm Dia G.I. Cap & Fittingand Fixing Over Thecasing Pipe Of Bore Well Properly And Taking It Out As Per Direction Of E/I. , Supplyingmaterials And Labours For Constructing Bore Well Chamber Of 75B Designation Brick Masonry Chamber 600Mmx450mm And 750Mm Deep Internal Dimension Having 250Mm Thickness In Cement Mortar 1:6 Including 12Mm Cement Plaster 1:6 With 600Mmx475mm Rcc Cover With Earth Work In Excavation And 75Mm Thick Pcc(1:3:6) In Foundation And Refilling All Complete As Per Specification And Direction Of E/I. , 2 H.P. D.C. Solarmotor Pump Complete Set , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Ecofriendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 1 Hp (Dc Pump) With 1800 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 100 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Provision Of Solar Night Lamp. , 12000 Litre Capacityr.C.C. Water Tank (2.7 X 2.7 X 2M Internal Size) With 10 M Staging Having Utility Room At Ground Level , Earth Work In Excavation In Foundation Trenches In Ordinary Soil (Vide Classification Of Soil Item-B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 M Including All Lifts,Levelling,Ramming The Foundation Trenches, Removing Roots Of Trees Shrubs All Complete As Per Approved Design, Building Specification And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening, Mixing Cement Concrete In Mixer And Placing In Position,Vibrating,Curing,Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Providing And Laying In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal For Rcc Work In Foundation Like Raft, Grillage, Strip Foundation And Footing Of Rcc Columns And Steel Stanchions Including Normal Dewatering, Plywood Form Work, Bully/Steel Propups, Compaction, Finishing Andcuring, Etc, Complete. (By Weigh Batching And Mix Design For M-250Only. Use Of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted.) , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only.Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Column From G.L To Roof Beam Of Utility Room , Column From Roof Beam To Tank Beam Of Utility Room , Column From Tank Beam To Tank Roof Of Utility Room , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Bracing , Beam Of Tank Floor , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) (Excluding M.S, Or Tor Reinforcement) For Rcc M-300 Grade Slabs / Landings / Vertical Walls Section-G-Plain And Reinforced Cement Concrete , Tank Floor Roof , Tank Roof Top , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads Including Cost Of Materials,Labours,Royalityand Taxes All Complete As Per Building Specification And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Filling In Foundation Trenches And Plinth In Layers Not Exceeding 150Mm Thick, Well Watered,Rammed,Fully Compacted And Fine Dressed With Earth Obtained From Excavation Of Foundation Trenches Within A Lead Of 50M And Lift Of 1.5M All Complete As Per Building Specifications And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 75 A Brick Work In C.M(1:6) In Foundation And Plinth With Approved Quality Of Clean Coarse Sand Of F.M.2 To2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints To 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In C.M(1:6) In Superstructure With Approved Quality Of Clean Coarse Sand Of F.M 2 To 2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Bldg. Specification And Direction Of E/I. , Providing R.C.C.M-200 In Nominal Mix Of (1:1.5:3) In Lintel With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Of F.M 2.5 To 3 Including Screening, Centering, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating Striking, Curing(But Excluding The Cost Of Reinforcement),Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Av.63 Mm Thick R.C.C M-200 In Nominal Mix Of (1:1.5:3) Chhajja With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including In Mixer And Placing In Position,Vibrating,Striking,6Mm Cement Plaster(1:4) In Ceiling And Sides Of Chhajja With Sand Of F.M 1.5, Curing(But Excluding The Cost Of Reinforcement) Taxes, And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing T.M.T Steel Reinforcement Of Different Dia Rods As Per Approved Design And Drawing Including Carriage Of M.S Bars To Work Site, Cutting Bending And Binding With Annealed Wire With Cost Of Wire, Removal Of Rust, Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing M.S Grill Made Of 20*6 Mmm.S Flats As Per Approved Design And Drawing, Properly Fabricated With Joints Continuous Fillet Welded And Finished Smooth, Carriage Of Grill To Work Site, Hoisting As Per Building Specification And Direction Of E/I. , Providing And Fixing Fan Hooks Of 16 Mm Dia M.S.Bar & 1 Meter Long Bent To Required Size And Shape, Placed In Position And Fixed In The R.C.C. Slab/Beam At The Time Ofcasting All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing 20 Gauge G.C.I Sheet Gate Fitted On M.S Angle Frame Of Size60*60*6 Mm Including Cost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In C/C(1:2:4) Blocks Of Required Size, Applying A Priming Red Lead Paint Over Steel Work, Taxes All Complete As Per Drawing Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:4) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:6) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 6 Mm Cement Plaster (1:4 ) In Ceiling With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With Floating Coat Of Neat Cement In Skirting Including Rounding Of Junctions With Floor,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 19 Mm Water Proof Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With 5% Cico Or Any Other Approved Water Proofing Compound Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 1.5 Mm Cement Punning Including Curing, Carriage Of Water With All Leads And Lifts As Per Building Specification And Direction Of E/I. , Providing Two Coats Of Snowcem Of Approved Shade And Make Over Old Surface Including Washing, Cleaning, Sand Papering The Wall,Scaffolding,Curing And Taxes All Complete As Per Building Specification & Direction Of E/I. , Extra For Each Coat Of Cement Wash, Distemper Paint Or Snowcem Over Exterior Surface For Each Consecutive Floor Above First Floor Including Scaffolding Etc All Complete As Per Building Specification & Direction Of E/I. , Providing Two Coats Of Synthetic Enamel Paint Of Approved Shade And Make Over Steel Surface Throughly,Scaffolding And Taxes All Papering Including Cost Of Scaffolding And Taxes All Complete As Per Building Specification & Direction Of E/I. , Providing And Fixing G.I. Pipe Railing Having 1.0 M Height Consisting 50 X 50 X 6 Mm Thick M. S. Angles As Verticals At 1.5 M C/C, And Additional Posts At Every Corner With 3 Rows Of 25 Mm Dia G.I. Pipes Of Medium Class Variety As Horizontal And Painting 3 Coats Of Oil Paint Over 1 Coat Of Anticorrosive Paint Of Approved Colour And Shade Including Cost Of All Labour, Transporting Bends To Curved Shape, Etc. Complete. , Providing And Fixing In Position M.S. Ladder 0.50 M Wide Consisting Of 75 X 10 Mm M.S. Flats As Stringers And 16 Mm Dia M.S. Bars In Double Rows As Steps Placed At 25 Cm C/C Including Cost Of Material And Labour Involved, Welding, Anchoring And Applying 3 Coat Of Anti-Corrosive Paint, Etc. Complete As Directed By Engineer-In-Charge. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Distribution Network & House Connection 40 - 60 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 65 Mm Dia. , 50 Mm Dia. , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , Distribution , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 32 Mm Dia And Weight Not Less Than 700 Gms , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5.Full Way Valve Chamber , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Galvanised Chain - Link Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm( 12) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil (Vide Classification Of Soil Item-A) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Eartrh Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening,Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing,Taxes And Royalty All Compelete As Per Building Specification Direction Of E/I. , Labour Cost Offitting And Fixing Galvanised Chain -Link Mess Up Height Of 2 Mincluding Cost Of Staples (But Excluding The Cost Of Cement Concrete Angle Iron Posts,Its Cutting And Making Holes,Nuts And Bolts) All Complete As Per Specification And Direction Of E/I. , Drilling 6 Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc.As Per Building Specification And Direction Of E/I. , Labour For Cutting Of M.S Angle Iron Posts To Required Length,One End Splitted As Fish Tailed In A Length Of 150 Mm Compelete As Per Building Specification And Direction Of E/I. , Supplying,Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Compelete As Per Building Specification And Direction Of E/I. , Supplying,Fitting And Fixing Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Fitted Onm.S. Angle Frame With Two Diagonals Having 25 X 25 X 5 Mm Size Angleincludingcost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In Angle Post,,Applying A Priming Red Lead Paint Over Steel Work,Taxesexcluding The Cost Of Galvanised Chain -Link Mess All Complete. , Cost Of Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Wt Not Less Than 3.1 Kg / Sq M , Cost Of 50 X 50 X 6 Mm M.S. Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc (01 Sim Each Year) , Model- 04 (16000 Litre 12 M Staging) , Construction Of 200 Mm X 165 Mm X 120.00 M Deep High Yield Drilled Tube Well , Hydt : Cost Of Drilling 200Mmx165mmx125 Mtr Deep Bore Well In All Kinds Of Soil And Rock In Rural Area For Installation Of Pump Bore Set With Hydraulic Dth Rig Machine, All Complete Including Supplying All Materials, Tools, Drilling Rig, Air Compressor And Equipments, As Well As Fuel, Lubricants And Cost Of Transportation Of Rig Machine And Other Vehicles Up To The Site. , (A) 0.00M Up To 50.00M Depth Below G.L. In Rural Areas , (B) Above 50.00 M Depth. In Rural Areas , Supplying All Tools, Tackles & Lowering Of 200 Mm Dia Ms Erw Casing Pipe Of 6Mm Wall Thickness Including Welding Charges, Cost Of Pipe Etc. All Complete Job. , Supplying All Materials, Labour, Tools & Equipments For Fitting & Fixing 200Mm Dia Ms Cap Over Casing Pipe Complete Job. , Supplyingmaterials And Labours For Constructing Bore Well Chamber Of 75B Designation Brick Masonry Chamber 600Mmx450mm And 750Mm Deep Internal Dimension Having 250Mm Thickness In Cement Mortar 1:6 Including 12Mm Cement Plaster 1:6 With 600Mmx475mm Rcc Cover With Earth Work In Excavation And 75Mm Thick Pcc(1:3:6) In Foundation And Refilling All Complete As Per Specification And Direction Of E/I. , 2 H.P. D.C. Solarmotor Pump Complete Set , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic (Spv) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0) , Ii) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km/H. , Iv) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. (As Per Mnre Specification) , Vii) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii) The Suction/Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg/Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg/Sq Cm- Pe 100 Grade For 5 Hp. , Ix) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X) The Motor Pump Set Should Have A 5 Years Warranty. , Xi) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. (As Per Mnre Specification) , Xii) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii) The System Should Be As Per Mnre Guide Line & Ecofriendly With Suitable Arrangement To Operate New Pump Manually. , Xiv) With Third Party Inspection Before Dispatch. , Xv) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array ,The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A) Name Of The Manufacturer Or Distinctive Logo. , B) Model Number. , C) Serial Number. , Solar Submersible Motor Pump (Spv Dc Type) , I) 2 Hp (Dc Pump) With 1800 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 100 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. (As Per Latest Guide Line Of Mnre) , Provision Of Solar Night Lamp. , 16000 Litre Capacityr.C.C. Water Tank (2.7 X 2.7 X 2M Internal Size) With 12 M Staging Havingutility Room At Ground Level , Earth Work In Excavation In Foundation Trenches In Ordinary Soil (Vide Classification Of Soil Item-B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 M Including All Lifts,Levelling,Ramming The Foundation Trenches, Removing Roots Of Trees Shrubs All Complete As Per Approved Design, Building Specification And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening, Mixing Cement Concrete In Mixer And Placing In Position,Vibrating,Curing,Taxes And Royalty All Complete As Per Building Specification Direction Of E/I. , Providing And Laying In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal For Rcc Work In Foundation Like Raft, Grillage, Strip Foundation And Footing Of Rcc Columns And Steel Stanchions Including Normal Dewatering, Plywood Form Work, Bully/Steel Propups, Compaction, Finishing Andcuring, Etc, Complete. (By Weigh Batching And Mix Design For M-250Only. Use Of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted.) , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only.Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Column From G.L To Roof Beam Of Utility Room , Column From Roof Beam To 2Nd Bracing Beam Of Utility Room , Column From 2Nd Bracing Beam To 3Rd Bracing Beam , Column From 3Rd Bracing Beam To Tank Base , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) , Bracing , Beam Of Tank Floor , Providing And Casting In Situ Cement Concrete Of Trap/Granite/Quartzite/ Gneiss Metal Of Approved Quality For Rcc Work As Per Detailed Drawings And Designs Or As Directed By Engineer-In-Charge Including Normal Dewatering, Centering, Plywood Formwork, Bully/Steel Prop-Ups, Compaction, Finishing The Formed Surfaces With Cm 1:3 Of Sufficient Minimum Thickness If Special Finish Is To Be Provided And Curing, Etc. Complete. (By Weigh Batching And Mix Design For M-250 And M-300 Only. Use Of L&T, A.C. C., Ambuja, Birla Gold, Manikgad, Rajashree, Etc. Cement Is Permitted) (Excluding M.S, Or Tor Reinforcement) For Rcc M-300 Grade Slabs / Landings / Vertical Walls Section-G-Plain And Reinforced Cement Concrete , Tank Floor Roof , Tank Roof Top , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads Including Cost Of Materials,Labours,Royalityand Taxes All Complete As Per Building Specification And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes Royalty All Complete As Per Building Specification And Direction Of E/I. , Filling In Foundation Trenches And Plinth In Layers Not Exceeding 150Mm Thick, Well Watered,Rammed,Fully Compacted And Fine Dressed With Earth Obtained From Excavation Of Foundation Trenches Within A Lead Of 50M And Lift Of 1.5M All Complete As Per Building Specifications And Direction Of E/I.(Mode Of Measurement-Compacted Volume). , Providing Designation 75 A Brick Work In C.M(1:6) In Foundation And Plinth With Approved Quality Of Clean Coarse Sand Of F.M.2 To2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints To 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Designation 75A Brick Work In C.M(1:6) In Superstructure With Approved Quality Of Clean Coarse Sand Of F.M 2 To 2.5 Including Providing 10Mm Thick Mortar Joints, Cost Of Screening,Scaffolding,Raking Out Joints 15Mm Depth,Curing,Taxes And Royalty All Complete As Per Bldg. Specification And Direction Of E/I. , Providing R.C.C.M-200 In Nominal Mix Of (1:1.5:3) In Lintel With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Of F.M 2.5 To 3 Including Screening, Centering, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating Striking, Curing(But Excluding The Cost Of Reinforcement),Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing Av.63 Mm Thick R.C.C M-200 In Nominal Mix Of (1:1.5:3) Chhajja With Approved Quality Of Stone Chips (20Mm To 6Mm Size) Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including In Mixer And Placing In Position,Vibrating,Striking,6Mm Cement Plaster(1:4) In Ceiling And Sides Of Chhajja With Sand Of F.M 1.5, Curing(But Excluding The Cost Of Reinforcement) Taxes, And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing T.M.T Steel Reinforcement Of Different Dia Rods As Per Approved Design And Drawing Including Carriage Of M.S Bars To Work Site, Cutting Bending And Binding With Annealed Wire With Cost Of Wire, Removal Of Rust, Placing The Rods In Position All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing M.S Grill Made Of 20*6 Mmm.S Flats As Per Approved Design And Drawing, Properly Fabricated With Joints Continuous Fillet Welded And Finished Smooth, Carriage Of Grill To Work Site, Hoisting As Per Building Specification And Direction Of E/I. , Providing And Fixing Fan Hooks Of 16 Mm Dia M.S.Bar & 1 Meter Long Bent To Required Size And Shape, Placed In Position And Fixed In The R.C.C. Slab/Beam At The Time Ofcasting All Complete As Per Building Specification And Direction Of E/I. , Supplying, Fitting And Fixing 20 Gauge G.C.I Sheet Gate Fitted On M.S Angle Frame Of Size60*60*6 Mm Including Cost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In C/C(1:2:4) Blocks Of Required Size, Applying A Priming Red Lead Paint Over Steel Work, Taxes All Complete As Per Drawing Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:4) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:6) With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 6 Mm Cement Plaster (1:4 ) In Ceiling With Clean Coarse Sand Of F.M 1.5 Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 12 Mm Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With Floating Coat Of Neat Cement In Skirting Including Rounding Of Junctions With Floor,Curing,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 19 Mm Water Proof Cement Plaster (1:3) With Clean Coarse Sand Of F.M 1.5 With 5% Cico Or Any Other Approved Water Proofing Compound Including Cost Of Screening, Curing With All Leads And Lifts Of Water,Scaffolding,Taxes And Royalty All Complete As Per Building Specification And Direction Of E/I. , Providing 1.5 Mm Cement Punning Including Curing, Carriage Of Water With All Leads And Lifts As Per Building Specification And Direction Of E/I. , Providing Two Coats Of Snowcem Of Approved Shade And Make Over Old Surface Including Washing, Cleaning, Sand Papering The Wall,Scaffolding,Curing And Taxes All Complete As Per Building Specification & Direction Of E/I. , Extra For Each Coat Of Cement Wash, Distemper Paint Or Snowcem Over Exterior Surface For Each Consecutive Floor Above First Floor Including Scaffolding Etc All Complete As Per Building Specification & Direction Of E/I. , Providing Two Coats Of Synthetic Enamel Paint Of Approved Shade And Make Over Steel Surface Throughly,Scaffolding And Taxes All Papering Including Cost Of Scaffolding And Taxes All Complete As Per Building Specification & Direction Of E/I. , Providing And Fixing G.I. Pipe Railing Having 1.0 M Height Consisting 50 X 50 X 6 Mm Thick M. S. Angles As Verticals At 1.5 M C/C, And Additional Posts At Every Corner With 3 Rows Of 25 Mm Dia G.I. Pipes Of Medium Class Variety As Horizontal And Painting 3 Coats Of Oil Paint Over 1 Coat Of Anticorrosive Paint Of Approved Colour And Shade Including Cost Of All Labour, Transporting Bends To Curved Shape, Etc. Complete. , Providing And Fixing In Position M.S. Ladder 0.50 M Wide Consisting Of 75 X 10 Mm M.S. Flats As Stringers And 16 Mm Dia M.S. Bars In Double Rows As Steps Placed At 25 Cm C/C Including Cost Of Material And Labour Involved, Welding, Anchoring And Applying 3 Coat Of Anti-Corrosive Paint, Etc. Complete As Directed By Engineer-In-Charge. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Distribution Network & House Connection60 - 80 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil (Vide Classification Soil Item B) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E/I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of (1:1.5:3) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E/I. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket (Coupler), , 65 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 80 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe (Hdpe Pipe) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality(Screwed End). , 80 Mm Dia. , 65 Mm Dia. , Providing And Supplying High Density Polyethylene(Hdpe )Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg/Cm2 And 10 Kg/Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984/14151/12786/13488,Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10 , Lowering, Laying And Jointing H. D. P. E./M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 80 Mm Hdpe Pipe , 63 Mm Hdpe Pipe , Distribution , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 (Part 1/2004) Isi Mark /Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E/I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I./D.I. Main Including Drilling And Taping C.I./D.I. Main All Complete As Per Specification And Direction Of E/I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E/I. , 15 Dia And Weight Not Less Than 400 Gm , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E/I. , 32 Mm Dia And Weight Not Less Than 700 Gms , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement :4 Coarse Sand) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm (Inside) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. With Common Burnt Clay F.P.S.(Non Modular) Bricks Of Class Designation 7.5.Full Way Valve Chamber , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. (1:2:4) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. (1:4) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E/I. , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Bricks Lead 06 Km (Avg.) , Galvanised Chain Link Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm( 12) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil (Vide Classification Of Soil Item-A) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Eartrh Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E/I. , Providing P.C.C.M-150 In Nominal Mix Of (1:2:4) In Foundation With Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M 2.5 To 3 Including Screening,Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing,Taxes And Royalty All Compelete As Per Building Specification Direction Of E/I. , Labour Cost Offitting And Fixing Galvanised Chain -Link Mess Up Height Of 2 Mincluding Cost Of Staples (But Excluding The Cost Of Cement Concrete Angle Iron Posts,Its Cutting And Making Holes,Nuts And Bolts) All Complete As Per Specification And Direction Of E/I. , Drilling 6 Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc.As Per Building Specification And Direction Of E/I. , Labour For Cutting Of M.S Angle Iron Posts To Required Length,One End Splitted As Fish Tailed In A Length Of 150 Mm Compelete As Per Building Specification And Direction Of E/I. , Supplying,Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Compelete As Per Building Specification And Direction Of E/I. , Supplying,Fitting And Fixing Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Fitted Onm.S. Angle Frame With Two Diagonals Having 25 X 25 X 5 Mm Size Angleincludingcost Of Fabrication, Providing Necessary Locking Arrangement With Haskal And Domny Duly Fixed In Angle Post,,Applying A Priming Red Lead Paint Over Steel Work,Taxesexcluding The Cost Of Galvanised Chain -Link Mess All Complete. , Cost Of Galvanised Chain -Link Mess Having 3 Mm Thick Wire Cell Type 40 X 40 Mm Wt Not Less Than 3.1 Kg / Sq M , Cost Of 50 X 50 X 6 Mm M.S. Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E/I. , Cement Lead 10 Km (Avg.) , Sand Lead 36 Km (Avg.) , Stone Chips Lead 11 Km (Avg.) , Steel Reinforcement Lead 10 Km (Avg.) , Annual Operation & Maintenance Cost Based On Existing D/T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year (Excluding Repair Charges) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 18% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
47.
Power #9059240 Technical Bid
Annual Maintenance For Electromechanical Equipments At 450 Mw ( 3X150 ) Bhep Stage-Ii For Two Years. 2. Routine Maintenance For Electromechanical Equipments At 450 Mw ( 3X150 ) Bhep Stage-Ii For One Year- 1 Consumables, Tools Tackles And Welding Material & Other Misc. Items To Be Arranged By The Contractor ( For Routine Maintenance Of One Year ) 2 Cotton Waste 3 M-Seal ( 100 Gm Pack ) 4 Teflon Tape, Champion 3 / 4”X 12 M 5 Fevi Quick 2 Gm 6 Hexa Blade 1”X12” 7 Diesel 8 Petrol 9 M.T.O 10 Malmal Cloth 11 Markin Cloth 12 Duster Cloth 13 Rust Remover 14 Emery Cloth Tape 150 Mmx50mtr. Coarse P120 15 Led Bulb 12 Watt Crompton, Gold Medal 16 Holder Screw Type, 250W 17 Socket ( 16A ) ; Top ( 16A ) ; Switch ( 16A ) Reputed Make 18 Socket ( 6A ) ; Top ( 6A ) ; Switch ( 6A ) Reputed Make 19 Led Flood Lights 100 Watts 20 Led Flood Lights 50 Watts 21 Halogen Tube 1000 Watts 22 Loctite 406 ( 20Gram ) 23 Loctite 243 ( 250Ml ) 24 Cotton Hand Gloves 25 Marker Pens 26 Crc 226 ( 500Ml ) 27 Crc Hand Cleaning Scrub, 2 Litres Each 28 Crc Battery Protector 500 Ml Can 29 Crc Battery Cleaner 500 Ml Can 30 Crc-Co Contact Cleaner ( 400Ml ) 31 Pvc Tape / Insulation Tape 32 Collin Spray ( 500Ml ) 33 Detergent Cakes ( 250Gm ) 34 Dettol-Handwash ( 250Ml ) 35 Mcb Spn / Dpn 16A, 32A 36 Single Core Wire 4Mm2 37 4-Core Cable 2.5 Mm2 38 2-Core Cable 4 Mm2 39 Cfl Screw Type 7W, 9W 40 Hand Torchs Wipro Make Led Type 41 Power Hexa Blades 42 Thinner Ici 43 Nuts & Bolts Of Various Sizes ( 12X80 Mm Ss, 06X20 Mm, 08X30mm, 10X60 Mm, 12X70 Mm, 16X85 Mm Ms / Galvanized Etc. ) 44 Mp Grease / Lithium Based Oil Grease 45 Rccb, 63A, Tpn 46 Et 200 Olc 47 Simatic S7 300, Ai Sm 331, Isolate 8Ai, Resolution 9 / 12 / 14 Bits 48 Hydrometer 49 Blower 50 Tarpaulene & Plastics 51 400W Hpi-T / Mhl Plus Bulb 52 Bulb 250W Hpi-T / Mhl Plus 53 Tube 150W Hpi 54 Ballast 400 W Hpi 55 Ballast 250 W Hpi 56 Ballast 150W Hpi 57 Igniter 250W-400 W 58 Capacitor 33 Micro F 59 Electronic Chokes 36 W Double, Single 60 Anabond 666 Silicone Rtv 61 Tap Sets 4Mm To 16Mm 62 Measurement Tapes 5 Mts 63 Clamp Meter Digital 0 To 1000 A Ac / Dc 64 Phoenix Power Supply 110V , 24V Dc 65 Rubber Hose ¾” 66 Rubber Hose 1” 67 Nitrogen Cylinder Vessel With Gas 250 Bar, 10 Cum Capacity, 99.99 % Purity 68 Folding Ladder 6 Steps 69 Floor Mops 70 Floor Brooms 71 Floor Wipers 72 Srubbers 73 Phenyl 74 Dust Bins, 60 Litres Capacity 75 Surf, 60 Grams Pouch 76 Buckets, 25 Litres Capacity 77 Nepthalene Balls 78 Plastic Trays, 5 Litres Capacity 79 Flush Cleaners, 1 Litres Each 80 Contacts Of Starter For Dewatering Pumps 110 Kw Each 81 Excitation Panel Filter Cloth 82 Electronic Choke / Blast 20 Watts 83 Flourecent Tube Rod 18Watt 2 Ft 84 Flourecent Tube Rod 36 Watt 4 Ft 85 Choke / Blast 36 Watts 86 Tube Light 36 Watt ( Tkc 24 ) 87 Tea , Coffeee, Soup Dispenser Alongwith Edible Refill Packs For Each For 24 Months 88 Welding And Miscellaneous Itemsfor 3 Machines 89 Welding Holder, 600A 90 Grinder Ag 4 91 Grinder Ag 5 92 Grinder Ag 7 93 500 Watts Professional Drill Machine With All Size Bits 94 Welding Electrode Cast Iron 95 ( 720Watt , 2.0J, 2.3 Kg ) , Corded Electric Professional Rotary Hammer 96 Pipe Wrench ( 8 Inch Wide Jaw Adjustable ) 97 Wire Brush 98 Eletrical Tool Kit ( Screw Drivers Set, Combination Pliers, Side Cutter, Nose Plier, Wire Stripper, Soldering Iron Set, Tester Etc. Complete ) 99 Eye Bolts ( 8, 10, 12, 16, 20, 24, 30, 32 No. ) Each 100 Rotary Barrel Pump ( 50-210 Litres ) 101 Hot Air Blower 102 Chipping Hammer 103 Tools & Tackle To Be Supplied By Contractor ( For Rmc ) 104 D-Spanner Ring 6Mm To 46Mm 105 Ring-Spanner Ring 6Mm To 46Mm 106 Eye Bolt Ss M12, M16, M24, M 20 107 D Shackle 2Ton To 6 Ton 108 Ratchet Socket 109 Triffer 5 Ton ( Chain Block ) 110 Hydraulic Jack 25 Tons 111 Ball Pin Hammer 112 Sledge Hammer 113 Screw Driver Bit Set ( 42 Bits Set ) 114 Nylon Sling 2Tons, 2Mtrs Each 115 Nylon Sling 5Tons, 2Mtrs Each 116 Nylon Sling 10Tons, 2Mtrs Each 117 Digital Multimeter Fluke Make 118 Hd Vacuum Cleaner 119 Hose Cutter 120 Dial Gauge With Stand 0.01Mm Accuracy 121 Allen Key Set 2-16 ( Ss ) 122 I R Testing Equipment15 Kv Reputed Make 123 Allen Key Set 17, 22, 24 ( Ss ) 124 Supply Of Precision Tools ( For Rmc ) 125 Vernier Calliper Upto 150Mm 126 Vernier Calliper Upto 600Mm 127 Telescopic Guage 128 Manpower For Routine Maintenance Of Power Plant Of Bhep-Ii ( Excluding The Period Of 25 Days During Which The Units Remain Under Shut Down One By One Annualmaintenance ) . For 3 Machines 129 Manager Mba / B.E / B.Tech ( Electrical ) 130 Engineer ( B.E / B.Tech Electrical ) 131 Engineer ( B.E / B.Tech Mechnical ) 132 Electrician Highly Skilled 133 Welder Cum Grinder 134 Mechanic / Fitter Highly Skilled 135 Electric Crane Operator 136 Helper Skilled 137 Cook, Mess Helper Etc. 138 Sweeper / Floor Cleaner 139 Other Monthly Misc Expenses For Annual Maintenancesuch As Hiring Charges Of Vehicles Incl Pol, Office Maintenance , Insurance Of Manpower , Mobilization Charges Extra ( For 3 Units )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
49.
Drinking Water Supply and Sanitation #8962450 Technical Bid
Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Giridih Panchayat Sihodih Village Bhalsumiya Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2021-22 Group No Svs-04 Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Giridih Panchayat Sihodih Village Bhalsumiya Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2021-22 Group No Svs-04 , Model:- 1B, 1 No. , Village:- Bhalsumiya , Tola:- Khas , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X50 X6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 12% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
50.
Drinking Water Supply and Sanitation #8962446 Technical Bid
Construction Of Mini Rural Water Supply Scheme Solar Motor Pump Complete Set In Block Giridih Panchayat Senadoni Village Tigojori Svs Group Of Scheme Under Jjm D.W.S. Division, No 2 Giridih For The Year 2021-22 Group No Svs-06 , Model:- 1A, 1 No. , Village:- Tigojori , Tola:- Tigojori-Ii , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Fitting, Fixing & Mounting On Water Tank Steel Structure. , Xvi ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I ( Mode Of Measurement Compacted Volume ) , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-200 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. ( Bcd-Sor ) Part- A 7.2 C Case 1 , ( A ) Foundation For Steel Structure Staging , Footing , Vertical Pedestal , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , 10 Mm Dia , 12 Mm Dia , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging For ( 4.5M ) Hdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanised Tubular Hollow Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Providing Structural Steel Work In Trusses Other Similar Trussed Purlins And Members With Bracing Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge Including Cutting Fabricating Hoisting Erecting And Fixing In Position Making Reverted Bolted Welded Connections One Coat Of Anticorrosive Paint And Over It Two Coats Of Oil Painting Etc Complete ( Mjp 2019-2020 Sec F Item 6 ) , Materials And Labour For Vinyl Painting Of Matter Given By Department In Different Color ( As Per Market Rate ) , Installation Of 2000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 2000.00 Litres Capacity Water Storage Tank ( Dwsd Item No-01 M ) , Transportation Charge , Lifting Of 2000 Litrs Capacity Tank Up To 4.5M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 10 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete. , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion. , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution Main , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. Pe-80 , Pn- 10. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe- , 20 Mm Hdpe Pipe- , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65Mm Dia , 50 Mm Dia . , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , For Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. , Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job. , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , Model:- 1B, 1 No. , Village:- Tigojori , Tola:- Tigojori-I , Tube Well , Drilling Portion , Construction For 115 / 125 Mm Dia Drilled Tube-Well For Drilling In All Kinds Of Soil Rock For Installation Of Hand Pump With D.T.H Rig Machine All Complete Including Supplying All Materials, Labours, Tools, Drilling, Rigs, Air Compressor And Equipments As Well As Fuel Lubricant For Making 125 / 115 Mm Dia Boring Etcand Cost Of Transporting Rig Machine And Other Vehicle Up To Site Workas Per Specification And Direction Of Engineer-In-Charge. , ( A ) Up To 30Mtr. Depth Bellow G.L. In Rural Areas , ( B ) Beyond 30Mtr.In Rural Areas , Providing All Equipments And Labour For Lowering 125Mm Dia Blue Upvc Casing Pipe As Casing For Protecting The Side From Falling During The Process Of Drilling All Complete Job Including Carriage Of Material To Work Site. , Supplying Labour Cement And Calcium Chloride Or Bentonite Solution And Equipments For Grouting To Casing Pipe All Complete Job Including Carriage Of Material To Work Site As Per Specification & Direction Of E / I , Supplying All Tools, Equipments And Labour And Doing Washing, Flushing And Development Of Drilled Tube Well To Give Clean And Clear Water All Complete As Per Direction E / I. , Supplying All Materials Labours And Equipment Including 125 Mm Dia Gi / Ci Cap 125 Mm Dia T / W Properly All Complete And Taking It Out As Per Specification & Direction Of E / I. ( The Cap Will Be Property Of Department ) , Civil Portion , Supplying All Tools, Equipment, Labours And Lowering 32 Mm Dia G.I. ( Medium ) Pipe In Dt In 3 Mtr. Length All Complete Job As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Tools, Labour For Fitting And Fixing Deep Well Cylinder With Necessary Connecting Rod All Complete Job As Per Specification & Direction Of E / I. , Supplying All Materials, Labours For Fitting And Fixing Of India Mark Ii Hand Pump With All Accessories All Job Complete As Per Direction Of E / I. Including Carriage Of Materials. , Supplying All Materials, Labours And Equipment For Constructing Pcc ( 1:2:4 ) Circular Platform Around Each Drilled Tube Well Including 12Mm Thick Cement Plaster ( 1:4 ) With Neat Cement Punning Over Exposed Surface As Per Unicef Design Etc. All Complete. Including Carriage Of Materials. , Supplying All Materials Labour And Equipment For Constructing Pcc ( 1:2:4 ) Drain As Per Unicef Design Etc. All Complete .Including Carriage Of Materials. , Add Extra Item For Supplying Tools, Labours And Materials For Painting, Numbering And Year For Construction Of T / Well And Taking Of Colour Photograph With Two Or Three Nearest Persons Including Platform, Drain, Soak Pit And Also Longitude & Latitude, Details Of T / W Such As Total Depth, Casing Depth, Static Water Level, Drawdown, Discharge, Strata Chart, Beneficiary Population Etc In Separate Sheet / Format All Complete As Per Direction Of E / I. , Cost Of Materials , Cost Of Standard I.S.I. Mark Deep Well Hand Pump For India Mark-Ii, I.S.I. 15500 ( Part 2 ) / 2004 With Latest Revision Including 12Mm X 3 Meter Long 8 No. Connecting Rods Made Of Bright Bar Electro-Galvanized Fitted With Coupler & Normal Stand Assembly Recommended For Use With Cylinder Assembly Suitable For Bore Wellcasing Pipe. , Cost Of 32 Mm Dia Gi Pipe ( Medium ) 3 Mtrs Long Screwed At Both Ends With Seamless Socket As Per Is:1239 ( Part 1990 ) . , Cost Of 125 Mm Dia Blue Upvc Casing Pipe As Per I.S.12818 / 2016 Cml No.- 5543459 , Rcc Foundation For Steel Structurestaging& Solar Panel , Earth Work In Excavation In Foundation Trenches In Ordinary Soil And Disposal Of Excavated Earth As Obtained To A Distance Up To 50.0M , Including All Lifts, Levelling , Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design , Building Specification And Direction Of E / I ( Vide Classification Of Soil Item -B ) , Providing Coarse Clean Sand In Filling In Foundation Trenches Or In Plinth Including Ramming And Watering In Layers Not Exceeding 150Mm Thick With All Leads And Lifts Including Cost Of All Materials , Labour , Royalty And Taxes All Complete As Per Building Specification And Direction Of E / I , Providing Designation 75 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering Taxes Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Nominal Mix Pcc Of ( 1:4:8 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I , Providing Rcc M-20 In Nominal Mix Of ( 1:1.5:3 ) In Columnswith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5To 3 Including Screening Shuttering Mixing Cement Concrete In Mixer And Placing In Position Vibrating Striking Curing And Royalty All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Footing And Vertical Pedestal Raft , Column , Tie Beam , ( B ) Foundation For Solar Panel , Footing , Vertical Pedestal , Providing For Steel Reinforcement As Per Approved Design And Drawing Excluding Carriage Of T.S. Bar To Work Site Cutting, Bending With Annealed Wire With Cost Of Wire, Removal Of Rust Placing The Rods In Position All Complete As Per Building Specification And Direction Of E / I. , ( A ) Foundation For Steel Structure Staging , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Bricks Lead 20 Km ( Avg. ) , Galvanized Tubular Steel Structure Staging Forhdpe Water Storage Tank& Solar Panel , Providing Structural Steel Galvanisedsqure Pipe Section Work In Trusses, Other Similar Trussed Purlins And Members With All Bracing , Gusset Plates Etc As Per Detailed Design And Drawing Or As Directed By Engineer- In-Charge , Including Cutting Fabricating , Hoisting , Erecting And Fixing In Position , Making Riveted / Bolted / Welded Connections And One Coat Of Anticorrosive Paint And Over It Two Coat Of All Oil Painting & For Structure ( Plus ) Providing And Applying Materials &Labour For Hot Dip Galvanizing Of Above Structure Including Transportation For Galvanizing Minimum Thickness 80Microns ( Net Wt. Of Components To Be Galv ) Preferably Tata Structural Section Etc Complete. , Hardware ( L.S. ) , Information Board For Iec , Installation Of 5000 Liters Capacity Water Storage Tank , Providing And Fixing Hdpe Container Syntex Or Alike One Piecemolded Water Tank Made Out Of Low Density Polythyler Andbuilt Corrugation Including Of Delivery Up To Destination Hoisting And Fixing Of Accessories Such As Inlet, Outlet Overflow Of All Tanks Capacity 5000.00 Litres Capacity Water Storage Tank , Transportation Charge , Lifting Of 5000 Litrs Capacity Tank Up To 4.00M Height With Lifting Tools With Rope And Labour , Making Hole In Tank , Making Long Screw In G.I. Pipe Including Supplying And Fitting Jam Nuts And Extra Socket Etc. , Rising And Distribution Network With House Connection Up To 20 Nos. Including Platform & Stand Post , Earth Work In Excavation In Foundation Trenches In Hard Soil ( Vide Classification Soil Item B ) And Disposal Of Excavated Earth As Obtained To A Distance Up To 50 Mtr. Including All Lifts, Leveling, Ramming The Foundation Trenches, Removing Roots Of Trees, Shrubs All Complete As Per Approved Design, Specification And Direction Of E / I. , Dismantling Plain Cement Concrete Work Including Stacking Serviceable Materials In Countable Stacks Within 15 M Lead And Disposal Of Unserviceable Materials With All Leads All Complete , Providing Pccm-200 With Nominal Mix Of ( 1:1.5:3 ) With Approved Quality Of Stone Chips 20 Mm To 6 Mm Size Graded And Clean Coarse Sand Of Fm 2.5 To 3.0 Including Screening, Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Sticking, Curing , Taxes And Royalty All Complete As Per Specification And Direction Of E / I. For Construction Of Road Cutting Portion , Rising Main , Manufacture, Supply And Delivery Offollowing Nominal Dia Upvc Column Pipes Including Pvc Socket ( Coupler ) , , 65Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:74.5 To 75.2Mm Wall Thickness End:9Mm To 10.7Mm, Barrel 9Mm To 10.7 Mm, Length: 3Mtrs.Rising Main , 50 Mm Dia -Density Of Pipe 1.38 To 1.43 Gm Per Cm3 Od:87.5 To 88.2Mm Wall Thickness End:9 .8 Mm To 11.9Mm, Barrel 7.3Mm To 9 Mm, Length: 3Mtrs. Delivery Pipe , Distribution , Providing And Supplying High Density Polyethylene Pipe ( Hdpe Pipe ) Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , 63 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing And Fixing Gun Metal Gate Valvewith C I Wheel Of Approved Quality ( Screwed End ) . , 65Mm Dia , 50Mm Dia , Providing And Supplying High Density Polyethylene ( Hdpe ) Fittings Of 20 Mm To 225 Mm Od And Pressure 6.0 Kg / Cm2 And 10 Kg / Cm2 Suitable For Water Supply Which Is Available In All Standard Conforming To Isi -- 4984 / 14151 / 12786 / 13488, Iso 4427 , Din-8074Materials Rates Are Ex-Factory Excluding Transportation, Taxes And Duties. , Lowering, Laying And Jointing H. D. P. E. / M. D.P. E. Pipes In Proper Position Including All Specials By Compression Fitting / Electro Fusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electro Fusion Machine, Electric Heater / Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labours As Directed By Engineer In Charge As Per Is-7634 Part Ii. , For Rising , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , Distribution , 65 Mm Hdpe Pipe , 50 Mm Hdpe Pipe , 32 Mm Hdpe Pipe , 20 Mm Hdpe Pipe , Providing 15 Mm Dia. G.I. Pipe Tata Or Equivalent Make As Per Is 1239 ( Part 1 / 2004 ) Isi Mark / Medium Quality In Stand Post. , Supplying All Materials , Labour And Tools For Fixing 15 Mm Dia G.I. Pipes With Red Lead And Yarn Of Following Nominal Bore With Screwed And Socketed Joints On Wall, Ceiling And Floor Including Supplying And Fitting Of Wall Hooks Or Pipe Clamps, Wooden Plugs, Cutting Pipes To Size And Threading Ends If Required Etc. All Complete As Per Specification And Direction Of Engineer-In-Charge. , Supplying And Fixing G.I. Fittings Of Approved Make All Complete As Per Specification And Direction Of E / I. , Elbow 15 Mm Dia. , Reducer Socket 20X15 Mm Dia. , Nipple 15 Mm Dia. , Plain Socket 15 Mm Dia. , Supplying And Fixing G.M. Ferrule Of Approved Make In Existing C.I. / D.I. Main Including Drilling And Taping C.I. / D.I. Main All Complete As Per Specification And Direction Of E / I. 3 Mm, 6 Mm 10 Mm Dm Ferrule Weight Not Less Than 425 Gram. , Providing And Fixing Gun Metal Full Way Valve Of Approved Quality, All Complete, As Per Specification And Direction Of E / I. , 65 Mm Dia Full Way Valve , 50 Mm Dia And Weight Not Less Than 1.5 Kg. , Providing And Fixing Of Male Ended C.I.Body Brass Spindle Valve And Seat Bib Cock Of Approved Quality With Extra Socketall Complete As Per Specification And Direction Of E / I. , 15 Dia And Weight Not Less Than 400 Gm , Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I. Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design.With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5. Full Way Valve Chamber , Supplying Materials , Labours And Equipments For Construction Of 0.90M X 0.90 M Size P.C.C. ( 1:2:4 ) Rectangular Platform With Stand Post In House Including 12 Mm Thick Cement Plaster In C.M. ( 1:4 ) With Neat Cement Punning Over Exposed Surfaceall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Providing Brick Masonry Chamber Ofinner Size 600 X 600 X 450 Mm Deep For Bore Well Protection Having 125 Mm Thick Wall And 75 Mm R.C.C Cover Including Cement Plaster Of Exposed Surface, Etc All Complete Job , Earth Work In Back Filling The Trenches After Laying Different Types And Size Of Pipes With Earth Removed During Excavation Within Initial Lead And Lift As Per Specification And Direction Of Engineer-In-Charge. , Providing Fitting & Fixing 32 Mm To 50 Mm Service Hdpe Saddleall Complete Job, As Per Approved Design, Specification And Direction Of E / I. , Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump , Designing, Supplying, Installation, Testing & Commissioning With All Tools & Parts Of Following Solar Photovoltaic ( Spv ) Solar Submersible D.C. Water Motor Pump Suitable For Minimum 125Mm X 115Mm Bore Well As Per Mnre Guideline With Following Specifications & Accessories. , Spv Arrays Contains Specified No Of Same Capacity Type & Specification Modules Connected To Series Or Parallel To Obtained The Required Voltage & Current The Power Output Of Individual Pvmodules Should Be Minimum 200 Watt Peak. , I ) The Spv Modules Should Be As Per Iec-61215 And Iec 61730 Part 1.0 ) , Ii ) All External Parts Of Motor Pump Used In Submersible Pump Which Are In Contact Of Water Is Stainless Steel Grade 303 Or Higher As Required. , Iii ) The Pv Modules Shouldbe Mounted On Metallic Structure Of Adequate Strength And Appropriate Design Which Can Withstand Load Of Modules & High Wind Pressure Up To 200Km / H. , Iv ) The Module Mounting Structure Should Be Hot Dip Galvanized According To Is 4759. , V ) To Enhance The Performance Of Spv Water Pumping System & Arrangement For Seasonal Tilt Angle Adjustment Should Be Provided , Vi ) Necessary Arrangement Should Be Provided In Controller Automatic Start-Run-Stop Through Out The Day With Water Level Detection System. ( As Per Mnre Specification ) , Vii ) Necessary Protection Such As Lightening Arrestor Etc. Should Be Provided To Protect The Controller & Spv , Viii ) The Suction / Delivery Pipe Shall Be Upvc / H.D.P.E. Pipes Of Appropriate Size 60M Or More As Required Minimum Pressure Rating Of 8Kg / Sq Cm- Pe 100 Grade For Pump Up To 3Hp & 10 Kg / Sq Cm- Pe 100 Grade For 5 Hp. , Ix ) All Cable Used Shall Be As Per Is 694. Suitable Size Of Cable Shall Be Used In Sufficient Length For Inter Connection Between The Spv Array To Spv Controller And Spv Controller To Solar Power Pump. Provision Of Cable Shall Be As Per Is 14536. , X ) The Motor Pump Set Should Have A 5 Years Warranty. , Xi ) Control Panel Suitable For Motor Pump With Arrangement Of Dry Run & Over Flow Protection Sensor, Float Switch & Rain Prevention Box. ( As Per Mnre Specification ) , Xii ) The Spv Controller Must Have Ip-65 Protection Or Must Be Housed In Cabinet Having At Least Ip-65 Protection. , Xiii ) The System Should Be As Per Mnre Guide Line & Eco-Friendly With Suitable Arrangement To Operate New Pump Manually. , Xiv ) With Third Party Inspection Before Dispatch. , Xv ) Provision For Web Basedremote Monitoring Of The Pumps To Be Installed Must Be Made Through The Inbuilt Controllers . It Should Be Possible To Ascertain The Daily Water Output, The Power Generated By Pv Array , The Up And Downtime Of The Pump During The Year, Number Of Days The Pump Was Unused Or Under Breakdown Repairs. , The Following Details Should Be Marked Indelibly On The Motor Pump Set , A ) Name Of The Manufacturer Or Distinctive Logo. , B ) Model Number. , C ) Serial Number. , Solar Submersible Motor Pump ( Spv Dc Type ) , I ) 1 Hp ( Dc Pump ) With 900 Wp Minimum Watt P.V. Panel As Mnre Pump Head Max Shut-Off Head Up To 120 Mtrs. For Higher Or Lower Head Or In Between Various Modules Output Could Be Decided On Prorates Basis. ( As Per Latest Guide Line Of Mnre ) , Carrying Out Recuperation / Yield Test For Ascertaining The Discharge Of Constructed Well / Excavated Profile As Directed By The Iec. The Testout By The Drawing Down Water From The Well / Profile Below Normal / Subsoil Water Level Up To Full Depth Rise Is Recorded The Normal Water Level / Subsoil Water Level In The Well / Profile As Well As Strainer / Level At Pump As Per Design Of W.S. Scheme Shall Be Recorded Prior To The Test Including Cost Of All Materials, Over Load , Labours Etc. Complete As Directed. , Supplying All Labours, Tools And Equipments For Dismantling Of Head & Water Tank Assembly And Taking Out 32 Mm Dia Old G.I. Pipe, Connecting Rod, Cylinder Assembly The Dismantled Components After Necessary Changing For Making The T / W In Good Condition With All Transportation Including Unused Taken Out Materials Back In Store All Complete Job As Per Direction Of E / I. ( As Per Model Estimate Of Solar Energy Based Mini Wss. Ts Done By Se, Ranchi Circle & Circle Gumla Dt. 21.05.2019 ) , Provision Of Solar Night Lamp. , Galvanised Chain-Line Mess Fencing Around Solar Panel Where Bore Well Is Away From Tower , Making 30 Cm ( 12 ) Dia Bore Up To 4M Below Ground With Hand Auger Of Approved Quality In Ordinary Soil ( Vide Classification Of Soil Item-A ) True To Plum And Without Eccentricity In Any Stage Of Operation And Disposal Of The Exacavated Earth Up To 50M Lead Including All Lifts All Complete As Per Approved Design And Direction Of E / I. , Providing Pcc M-150 In Nominal Mix Of ( 1:2:4 ) In Foundationwith Approved Quality Of Stone Chips 20Mm To 6Mm Size Graded And Clean Coarse Sand Of F.M.2.5 To 3 Including Screening Shuttering, Mixing Cement Concrete In Mixer And Placing In Position, Vibrating, Curing, Taxes And Royalty All Complete As Per Building Specification Direction Of E / I. , Labour Cost Of Fitting And Fixing Galvanised Chain-Link Mess Up Height Of 2 M Including Cost Of Staples ( But Excluding The Cost Of Cement Concete Angle Iron Posts, Its Cutting And Making Holes, Nuts And Bolts ) All Complete As Per Specification And Direction Of E / I. , Drilling 6Mm Dia Holes In M.S Angle Iron For Fixing Of Stables Etc. As Per Building Specification And Direction Of E / I. , Labour Cost Cutting Of M.S Angle Iron Posts To Required Length, One End Splitted As Fish Tailed In A Length Of 150Mm Complete As Per Building Sepcification And Direction Of E / I. , Supplying, Fitting And Fixing Straining Bolts With Nut Size 22Cm*10Mm Dia Tighten The Barbed Wire With Corner Post Complete As Per Building Specification And Direction Of E / I. , Supplying, Fitting And Fixing Galvanised Chain -Link Mess Having 3Mm Thick Wire Cell Type 40 X 40 Mm Fitted On M.S. Angle Frame With Two Diagonals Having 25X25x5mm Size Angle Including Cost Of Fabrication, Providing Necessary Bocking Arrangement With Haskal And Domny Duly Fixed In Angle Post, Applying A Priming Red Lead Paint Over Steel Work, Taxes Excluding The Cost Of Galvanised Chain-Link Mess All Complete. , Cost Of Galvanised Chain-Link Mess Having 3 Mm Thick Wire Cell Type 40X40 Mm Not Less Than 3.1 Kg / Sqm , Cost Of 50 X50 X6 Mm M.S Angle , Carriage Of Materials From Different Sources Or Departmental Stores To Work Site Including Loading, Transporting, Unloading And Stacking The Materials At Work Site Etc. All Complete Job. As Per Direction Of E / I. , Cement Lead 20 Km ( Avg. ) , Sand Lead 20 Km ( Avg. ) , Stone Chips Lead 20 Km ( Avg. ) , Steel Reinforcement Lead 20 Km ( Avg. ) , Annual Operation & Maintenance Cost Based On Existing D / T Well With Solarmotor Pump For 5 Years , O & M Cost For 1St Year ( Excluding Repair Charges ) , O & M Cost For 2Nd Year With Annual Repair Charges , O & M Cost For 3Rd Year , O & M Cost For 4Th Year , O & M Cost For 5Th Year , Provision Of One No Sim Card & Its Recharging Cost For Rmc , 12% Gst , Labour Cess
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
TenderDetail
Loading tenders