View Bid Results For Lubricated Plug Valves Tenders

We found 155 Bid Results related to lubricated plug valves tenders. You can find Contractor details who won lubricated plug valves tenders along with contract details in Bid awards announcements section.

Filters
Stage
121
29
5
Tender Publishing Platform
14
141
State / UT
21
22
20
19
17
14
13
11
9
5
3
3
3
3
2
2
2
2
2
1
1
1
Contract Value
55
46
37
17
Publish Date
1
0
0
0
0
Sector
15
70
23
18
14
6
5
3
3
3
3
2
2
1
1
1
Ownership
4
110
28
16
1
Within keyword
Active filters:
Showing 1–4 of 155 tenders matching your filters
Contract Date: Jun 15, 2026 Contract Value : 2.94 Lakh
Government Departments No of Bidders 1
Maharashtra View Result →
7.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
12.
Drinking Water Supply and Sanitation #10551292 Price Bid
Tender For Supply And Installation Of Energy Efficient Submersible Pump Sets Panels Cables And Other Allied Works And Connections With Existing System With Two Year Defect Liability Period Under Phed Div Banswara Annual Rate Contract - 1 Providing & lowering in tubewell ISI marked GI Pipe B class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3 mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect 2 nominal bore of 32 mm 3 nominal bore of 50 mm 4 nominal bore of 65 mm 5 Supply & fixing of ISI marked three core PVC flat submersible cable as per IS 694 : 1990 or amended up to date and conductor as per class 5 of IS 8130 : 1980 including making connecting etc 6 3 core 4.0 Sq.mm 7 3 core 6 Sqmm 8 3 core 10 Sqmm 9 3 core 16 Sq mm 10 Supply & Installation of 3 phase ISi marked submersible motor pump set of five star rating by BEE and as per JS: 8034-2011 (pump) and IS 9283-2013 (motor) or amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 11 Up to 5.5 KW (7.5 HP) & head up to 120 mtr. 12 Up to 5.5 KW (7.5 HP) & head above 120 mtr 13 7.5 KW (1O HP) & head up to 120 mtr. 14 7.5 KW (10 HP) & head above 120 mtr. 15 9.3 KW (12.5 HP) & head up to 120 mtr 16 9.3 KW (12.5 HP) & head above 120 mt 17 11 KW (15 HP) & head up to 120 mtr. 18 11 KW (IS HP) & head above 120 mtr 19 13 KW (17.5 HP) & head up to 120 rntr. 20 13 KW (17.5 HP) & head above 120 mtr 21 15 KW (20 HP) and above, head up to 120 mtr 22 15 KW (20 HP) and above, head above 120 mtr. 23 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy(Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft ofSS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.0 24 100 mm dia 25 125 mm dia 26 150 mm dia 27 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 28 Above 5 HP and up to 10 HP 29 Above 10 HP and up to 15 HP 30 Above 15 HP and up to 20 HP 31 Above 20 HP and up to 30 HP 32 Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 33 Centrifugal Monoblock Pump set (Single Stage) 34 2.2 KW (3.0 HP) 35 3.7 KW (5.0 HP) 36 5.5 KW (7.5 HP) 37 7.5 KW (10 HP) 38 9.3 KW (12.5 HP) 39 11.0 KW (15 HP) 40 15.0 KW (20.0 HP) 41 18.5 KW (25.0 HP) 42 Centrifugal Monoblock Pump set (Double Stage) 43 3.7 KW (5.0 HP) 44 5.5 KW (7.5 HP) 45 7.5 KW (10.0 HP) 46 9.3 KW (12.5 HP) 47 11.0 KW (15.0 HP) 48 15.0 KW (20.0 HP) 49 Providing, installation, testing and commissioningof Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water immersed, dry air filled, class F insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 50 15 KW 51 18.5 KW 52 22 KW 53 30 KW 54 37 KW 55 45 KW 56 55 KW 57 75 KW 58 90 KW 59 110 KW 60 125 KW 61 132 KW 62 160 KW 63 180 KW 64 200 KW 65 Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 66 2.2 KW (3.0 HP) 67 3.7 KW (5.0 HP) 68 5.5 KW (7.5 HP) 69 7.5 KW (10 HP) 70 9.3 KW (12.5 HP) 71 11.0 KW (15 HP) 72 15.0 KW (20.0 HP) 73 Supply & Fixing tube well cover of MS sheet 8mm thick at top & Smm thick I OOmm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both end in 80mm sizes passing through a hole in the centre of MS sheet. A 25mm socket with end plug shall also be welded over top plate (as per drawillg enclosed). A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall tie provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 74 125 mm dia 75 150 mm dia 76 200 mm dia 77 250 mm dia 78 Providing & Fixing pump safety cage as per specifications or as directedby engineer incharge 79 Providing & Fixing of double flanged, Cl body, ISi marked NR V of approved make of following sizes 80 65 mm dia 81 80 mm dia 82 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated CI Sluice valve of Class PN-1.0 83 80 MM 84 100 MM 85 125 MM 86 150 MM 87 200 MM 88 250 MM 89 300 MM 90 Providing supplying , Lowering & laying in standard lengths HDPE PE -80 PN-6 Pipes conforming to IS-4984:1995 with necessary jointing material like mechanical connectors, i.e thread/ insert joint/ oquick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion welding method,includingall taxes [ Central and local ], transportation and freight charges,inspection charges, loading/ unloading charges, stacking the same in closedshade duly protecting from sunrays and rains, includingcostof labourandmaterial, specials [ Tee, bend etc.] satisfactory, hydraulic testing etc. complate as per tachnical specifications and direction of engineer-in- charge. [excluding earth work] supply up to90mm dia. coil & above 90 mm dia straight leanth in 6 m.]NOTE : Providing and fixing of al requisite specials as per drawing, design and layout are inclusive in RM messurement ofthe item and shall not be paid separatelyin following nominal diameter. 91 90 mm dia 92 110 mm dia 93 Fabrication & Fixing M.S.Stand of specified class of angle iron L-shaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect. 94 Supply & fixing MS clamp set of 50 x 6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump sets 95 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 96 80 mm dia 97 100 mm dia 98 125 mm dia 99 150 mm dia 100 200 mm dia 101 250 mm dia 102 300 mm dia 103 350 mm dia 104 400 mm dia 105 Supply&FixingXLPEinsulated/P.V.C.sheathedcableof1.1KVgradewith aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground asperIS:1255includingexcavationof30cmx75cmsizetrench,25cmthick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 106 10.0 Sq.mm, 4 core 107 16.0 Sq.mm, 4 core 108 25.0 Sq.mm, 3.5 core 109 35.0 Sq.mm, 3.5 core 110 Plate Earthingas per IS:3043 with G.I. Earth plate ofsize 600mmx 600mmx 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete withalternatelayersofsaltandcoke/charcoal,testingofearthresistanceas required. 111 Supplying&Installing100mmdiametersealeddiaphragmbourdontype pressuregaugeofrange0to10kg. includingalljointingmaterialasper specification with safety cover. 112 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: 113 All kinds of soil 114 Ordinary rock 115 Hard rock (requiring blasting) 116 Hard rock(blasting prohibited)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
13.
Drinking Water Supply and Sanitation #10284454 Price Bid
Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Kewa Malikabad Of Jal Shakti ( Phe ) Mechanical Division South Awantipora Under Jjm.-2 Supply, Installation, Testing & Commissioning Of Submersible Pumping Unitas Per Is 8034 With Assumed Discharge & Specification Are As Under :Pump : Discharge: 8500 Gphat 100 M Headefficiency = Not Less Than 50%Speed= 2900 Rpmtype Of Pump= Mixed Flow.Type Of Fluid To Be Handled=Clear Watermaterial Of Construction:Impeller= Bronze Grad Ltb 2 Of Is 318 / Stainless Steel Grade X 12 Cr12of Is 6911 Or Is6603 / Cast Iron Fg200 Of Is210pump Shaft= Stainless Steel Ss 410.Pump Casing= Cast Iron / Stainless Steelimpeller:Impeller Is Of The Enclosed Or Semi – Enclosed Type And Properly Balanced.Enclosed Impellers Equipped With Seal Rings On Their Hubs. Coupling:A Suitable Coupling Arrangement Provided With Pump Set.Non Return Valve:- Non Return Valve Of The Suitable Size Provided Above The Pump Discharge Case.Motor:-Method Ofstarting = Star – Delta Speed= 3000 ( Sync ) .Frequency= 50 ± 3 % Hzworking Voltage= 380-415 ± 15% V, 03 Phaseefficiency = Not Less Than 90% Motor Rating=Not Less Than 25 Hpclass Of Insulation= Fsubmersible Motor Should Be Water Filled Water Lubricated Squirrel Cage Type Having Capacity For Above Pumping Parameters And Working On 3 Phase; Ac Supply Ranging From 380 To 415 Volts, 50Hz. The Motor Should Be Sealed By Radial Rings To Avoid Mixing Of Well Water With Motor Filled Water. A ) The Job Includes Providing And Fitting Of Interlocking Arrangement Against Any Failure Of Coupling. It Must Be Fabricated Out Of Ms Strips Of Suitable Size And Length.B ) The Job Includes Providing And Fitting Of Appropriate Size Ms Nipple 2 Feet Long Threaded On One End And Welded To Same Size Ms Flange Ofthickness ( As Per Table-17 ) . 3 Fabrication, Providing And Fitting Of Y- Junction Having 1M Length Of Each Arm To Be Fabricated Out Of Hot Dip Galvanized G.I, C-Class Pipe. The Job Also Includes Providing And Welding Of M.S Flanges To The Ends Of Each Arm. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17.100 C Heavy 4 Providing / Supplying And Fitting Of 100 Mm Diameter G.I Class B Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-B Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make.Flanges ( As Per Is 6392 / 1997 Table:17 ) Thickness Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint.Welding Electrodedc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm.Nuts And Boltsnuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gasketsrubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. The Rising Main Is To Be Laid As Per The Instructions Of The Engineer In Charge. 5 Earth Work In Excavation By Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed.All Kinds Of Soil 6 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M And Lift Upto 1.5M. 7 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units . The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions Rest Specification As Per Cluase 12 Of Sbdsize:100 Mmpn: 1.6 / 16 8 Providing And Fitting Of Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) . Rest Specification As Per Cluase 13 Of Sbd.Size:100 Mmpn: 1.6 / 16 9 Providing, Fitting, Testing And Commissioning Of Arv ( Air Release Valve ) As Per Is 14845 To Be Fitted To G.I Risingmain. The Arv Shall Have The Following Specifications: -I. Valve Type - Single Chamber, Single Orifice.Ii. End Connection - Flanged Ends To Is 1538 Iii. Working Temperature - 70Oc To 550 C Iv. Test Pressure - Body / Seat 2.5 X Pnv. Sealing Ring - Epdmvi. Construction -Ductile Iron With Stainless Steel Floatsvii. Coating - Epoxy With Corrosion Resistance Rest Specification As Per Cluase 14 Of Sbd. 10 Fabrication , Providing And Fitting Of90-120 Degree Bend / Elbowto Be Fabricated Out Of100mm Diameter Class-B, G.I Pipe, 1 M Lengthand Flanged On Both Ends Ato Make It Leak Proof. The Flanges Shall Be M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) And Welded On Both Sides. The Job Includes Nuts, Bolts, Gaskets Etc As Per Site Requirement. 11 Providing And Fitting Of 300 Mm In Length 100Mm-80Mm Dia Gi Reducer Bend Flanged On Both Sides, Flange Conforming To Table-17 ( Pn16 ) To Be Fitted With The Column Pipe / Delivery Manifold Of Submersible Pumping Unit To Join Rising-Main And Column Pipe / Delivery Manifold. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes From Inside And Outside Of Pipe To Form Strong Welding Joint. 12 Fabrication, Providing, Fitting T - Junction Out Of 1 Mtr Of Pipe With Length Of 1 Ft Each Arm The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Joints Rest Specification As Per Cluase 09 Of Sbdsize: 100 Mm Class: C ( Heavy ) 13 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded In All Respects A ) Verticial Posts Ismc 150B ) Ismc 75C ) Plate 12 Mm Thickd ) Ismb 200E ) Nuts And Bolts 10 Kg. 14 Earth Work In Excavation By Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed.All Kinds Of Soil 15 Providing And Laying Of Soling Stone 16 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centering And Shuttering. All Work Up To Plinth Level With 1: 2 : 4 ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) . 17 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation , Footings , Bases For Columns 18 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 19 Providing, Installation And Testing Of Manual Type Triple Spur Gear Chain Pulley Block Along With Monorail Geared Travelling Trolley Having Following Features Gears: - The Hoist Shall Have Precision Machine Case Hardened Alloy Steel Gear Mounted On Bearings And Housed In A Dust Proof Gear Box. The Lubrication Of Gears Should Be Of High Viscosity And Temperature For Longer Life Of Gears. Load Chain:- The Load Chain Be Made Of High Tensile Alloy Steel Having Wear Resistance And Greatest Mobility. Rest Specification As Per Clause 24 Of Sbd.Capacity: 2 Ton 20 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted With Accessories Detailed Specification As Per Clause --- Of Sbdmu-G 50 Rest Specification As Per Clause 43____ Of Sbd 21 Providing, Fitting, Testing And Commissioning Of Voltage Stabilizer As Per Specifications Below: Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multi Step. Type Of Regulator: Double Plate Type With Electrolytic Copper Contacts. Input Voltage: 250-400 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts. Frequency : 50 ±3 C / S. Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Rest Specification As Per Clause 44 Of Sbdrating: 50 Kva 22 Providing And Fitting Of 3.5-Core Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. Rest Specification As Per Cluase 71 Of Sbd50 Sq Mm, 3.5 Core Lt 1.1 Kv 23 Providing And Fitting Of 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. The Main Specification Of The Cable Is Given Below: Rest Specification As Per Cluase 47 Of Sbd.Size 16 Sq Mm 24 Providing And Fitting Of Pvc Insulated Copper Cable As Per Is 694- Along With Thimbling As Per Requirements Rest Specification As Per Clause 67 Of Sbd.Size: 16 Sq.Mm 1 Core Lt 1.1Kv 25 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards. Safe Earthing Electrode Size : 80 Mm Dia , Length : 2000 Mm Back Fill Compound : 30 Kg 26 Illumination Of Premises: Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items. 1 ) 3 Way Terminal Connector 20 Amp. 2 ) 3 No Mcb 8 Amp. Rest Specification As Per Cluase 50 Of Sbd 27 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36 Having Following Specs: Input: 90-240 V 50 Hz Power Factor: >0.9 Colour Temperature: 4K - 6.5K Beam Angle: 120° - 170° Lumens: >12000 Operating Temperature: -20°C To 60°C Rest Specification As Per Cluase 51 Of Sbd 28 Providing And Fitting Of 2 Core, Xlpe, 1.1Kv And 11Kv Grade Armoured Aluminum Cable Of Various Sizes Conforming To Is: 7098 Part 1St As Service Line From The Ht Transformer To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. Rest Specification As Per Cluase 71 Of Sbd.10 Sq Mm, 2 Core Lt 1.1 Kv 29 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer With Input Voltage 70- 240 V And Output 220 V. The Stabilizer Shall Be Installed And Connected To The Electric Circuit As Per Location Provided By Site In Charge. 30 Supply , Installation , Commissioning And Creation Of Pole Mounted, Outdoor Type Electric Sub Station As Per The Technical Specifications Given Here Under - Specifications Conforming To Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Type: Ht / Lt Transformer Type Of Cooling: Onan. Operating Conditions: Input =11000 Volts Output =433 Volts Ac Supply In 3- Phase. Terminals: Input=3 No. Ht Bush Rods With Insulators, Washer, Nuts Etc. Output=4 No. Lt Bush Rods Switch Insulators, Washers, Nuts Etc. Core: The Core Shall Be Of High Permeability To Reduce Core Losses And The Strips Shall Be Of Suitable Size And Gauge. Transformer Coils: Suitable Number Of Ht And Lt Coils In Each Leg Of The Core. The Transformer Coils Shall Be Fabricated Out Of Superior Quality Aluminum Wire / Strips, Properly Wound. The Ht Transformer Is Completely Filled With Suitable Grade Transformer Oil Up To Required Level. The Job Includes Carriage, And All Leads And Lifts Involved. The Ht Transformer Shall Be Of Reputed Make From An Iso Certified Company As Per Relevant Standards And A Test Certificate Shall Be Provided Before Installation. The Transformer Shall Also Be Provided With Breather Fill With Silica Jel Crystals, Conservator With Oil Level Indicator, Explosion Vet And Adequate Radiator Fins / Tubes. The Impedance Of Transformer Shall Be As Per Is: 1180 ( Part 1 ) 2014 With Latest Amendments. Note: The Scope Of The Work Shall Include Obtaining Of Necessary Inspection / Clearance Certificate From The Concerned Department For All The Required Equipment. The Testing And Commissioning Shall Be Completed Only After Obtaining Above Certificate.63 Kva 31 Providing And Fitting G.I Channel / Angle / Flat Of Sizes Including Clamps 32 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Of Ht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 33 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation 34 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, 10Ka, 9Kv, La With Polymer Housing, Station Type. 35 Supply And Fitting Of 11 Kv Polymeric Composite Pin Insulator 12 Kv, 5Kn, Lighting Impulse 75Kv Positive, And 80 Kv Negative , Creep Age Distance 320 Mm 36 Supply, Installation, Erection Of 9 Mtrs Long H.T Pope Of Specifications St- 410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories, Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 37 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement. 38 Earth Work In Excavation By Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan , Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed.All Kinds Of Soil 39 Providing And Laying Of Soling Stone Including Manual Compaction 40 Concrete Cement Bottoming 1:2:4 Mix As Per Rec Standards , 0.5 Cum / Pole 41 Providing And Fitting Of D- Clamps 42 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp , Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete 43 Painting Of Poles Red Oxide 44 Painting Of Poles Aluminum Paint 45 Supply, Installation, Testing Of 50 Sq Mm Xlpe Ht Cable ( Abc Type ) Of 11 Kv Grade With Following Specifications Size Cross Sectional Area In Square Mm ) =3X50 Phases Red, Yellow , Blue 46 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 47 Providing And Fitting Of Lt Distribution Box For H.T Transformer With Mccb For Incomer And Sfu For Outgoing Circuits. 48 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. With 2- Core 4 Mm 2 Cu ( 25 M ) Wiring As Per Site Requirement Along With Other Accessories Like Ss Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 49 Tool Kit For Maintenance: - The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below Shall Be Of Providing Of Tool Kit Consists Of Following Items I. Double Ended Spanner ( Chrome Plated ) 02 Sets Complete Ii. Double Ended Ring Spanners Chrome Plated 02 Sets Complete Iii. Allen Key Set Black Finish 02 Sets Complete Iv. Combination Pliers Insulated With Thick C.A Sleeve; Size In Mm 165, 210, 255 Each – 02 No. V. Long Nose Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Each – 02 No. Vi. Side Cutting Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Make – 02 No. Vii. Insulated Screw Drivers Blade Length In Mm Blade Dia. In Mm Tip Dimensions In Mm Quantity 50 3 1.6 X 0.4 02 75 3 1.6 X0.4 02 100 3 3 X 0.4 02 125 3.5 3.5 X 0.5 02 150 3.5 3.5 X 0.5 02 200 4 4 X 0.6 02 300 5 5 X 0.8 02 Viii. Hammer With Handle Weight – 110 Mg, 340 Gm , 600 Gm –Each – 1No. . Ix. Heavy Duty Pipe Wrench Length In Mm - 200, 300, 600 Each – 01 No. X. Electric Multimeter=1No Xi. Digital Multimeter – 1No. Xii. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xiii. Hack Saw Frame With Hack Saw Blade – 01 No. Xiv. S-16 Mxl, S- 16 H X L Socket Set ( 19 Sockets + 6 Accessories ) – 01 No. 50 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 51 Providing Of 1 Kw Heat Convector For Operators For Winter Season 52 Providing, Installation, Testing & Commissioning Of 415 ±10%V ( Output ) , 3 Phase Air Cooled / Water Cooled Diesel Generator Set As Per Is 8528 ( 2018 ) And Iso 3046 ( 2002 ) For Engine And Iec / Is 60034-1 For Alternator Suitably Assembled And Fitted In A Pollution Free Acoustic Enclosure / Canopy Of Required Size As Per Ministry Of Environment Protection Rule 1986 Read With Latest Amendments. The Dg Set Is Required To Be Fitted And Tested On Load At Site The D.G Set Shall Have The Following Technical Specification. Besides The Above Works The D.G Set Shall Be Provided With 12 V, 150 Ah Lead Acid Battery Of Reputed Make Fitted Inside The D.G Set Canopy Along With Necessary Accessories And Battery Charger Of Required Capacity. Rest Specification As Per Clause 66 Of Sbd.Rating: 40 Kva Dg Set Air Cooled
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
14.
Drinking Water Supply and Sanitation #10284392 Price Bid
Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments At Water Supply Scheme Turku Tachloo Of Jal Shakti ( Phe ) Mechanical Division South Awantipora Under Jjm.- 1 Supply, Installation, Testing & Commissioning Of Submersible Horizontal Monoset Pumping Unit For Raw Water Of River As Per Is 8034 With Following Specification Are As Under :Pump : Discharge: 10000 Gph At 19 Mts Headefficiency= Not Less Than 50% Speed= 2900 Rpmtype Of Pump = Mixed Flow.Type Of Fluid To Be Handled=Clear Watermaterial Of Construction:Impeller = Stainless Steel Pump Shaft = Stainless Steel Ss 410.Pump Casing = Cast Iron / Stainless Steelimpeller:Impeller Is Of The Enclosed Or Semi – Enclosed Type And Properly Balanced.Enclosed Impellers Equipped With Seal Rings On Their Hubs.Coupling:A Suitable Coupling Arrangement Provided With Pump Set.Non Return Valve:-Non Return Valve Of The Suitable Size Provided Above The Pump Discharge Case.Motor:-Method Ofstarting = Star – Delta Speed = 3000 ( Sync ) .Frequency= 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 Phaseefficiency = Not Less Than 90% Rating= Not Less Than 5 Hpclass Of Insulation =F / Suitable For Above Parameterssubmersible Motor Should Be Water Filled Water Lubricated Squirrel Cage Type Having Capacity For Above Pumping Parameters And Working On 3 Phase; Ac Supply Ranging From 380 To 415 Volts, 50Hz. The Motor Should Be Sealed By Radial Rings To Avoid Mixing Of Well Water With Motor Filled Water.A ) The Job Includes Providing And Fitting Of Interlocking Arrangement Against Any Failure Of Coupling. It Must Be Fabricated Out Of Ms Strips Of Suitable Size And Length.B ) The Job Includes Providing And Fitting Of Appropriate Size Ms Nipple 2 Feet Long Threaded On One End And Welded To Same Size Ms Flange Ofthickness ( As Per Table-17 ) At Other End For 80 Mm Diameter Column Pipe As Per Site Requirement. The Threaded Portion Should Be As Per Size Of Pumping Out Let For Proper Fixing.The Job Includes Providing And Fitting Of R. I. Cloth Joints / Rubber Washers With Nuts, Bolts And Washers For All Joints Of Column Pipe. The Job Also Includes Lowering Of Pumping Unit In The Well Then Proper Testing And Commissioning Of Pumping Unit On Full Load At Site.Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. 2 Supply, Installation, Testing & Commissioning Of Submersible Horizontal Monoset Pumping Unit For Pst / Sump To Liftwater Through Pressure Filterplant Upto Oht As Per Is 8034 With Following Specification Are As Under :Pump : Discharge: 10000 Gph At 45 Mts Headefficiency= Not Less Than 50% Speed= 2900 Rpmtype Of Pump = Mixed Flow.Type Of Fluid To Be Handled=Clear Watermaterial Of Construction:Impeller = Stainless Steel Pump Shaft = Stainless Steel Ss 410.Pump Casing = Cast Iron / Stainless Steelimpeller:Impeller Is Of The Enclosed Or Semi – Enclosed Type And Properly Balanced.Enclosed Impellers Equipped With Seal Rings On Their Hubs.Coupling:A Suitable Coupling Arrangement Provided With Pump Set.Non Return Valve:-Non Return Valve Of The Suitable Size Provided Above The Pump Discharge Case.Motor:-Method Ofstarting = Star – Delta Speed = 3000 ( Sync ) .Frequency= 50 ± 3 % Hz Working Voltage = 380-415 ± 15% V, 03 Phaseefficiency = Not Less Than 90% Rating= Not Less Than 15 Hpclass Of Insulation =F / Suitable For Above Parameterssubmersible Motor Should Be Water Filled Water Lubricated Squirrel Cage Type Having Capacity For Above Pumping Parameters And Working On 3 Phase; Ac Supply Ranging From 380 To 415 Volts, 50Hz. The Motor Should Be Sealed By Radial Rings To Avoid Mixing Of Well Water With Motor Filled Water.A ) The Job Includes Providing And Fitting Of Interlocking Arrangement Against Any Failure Of Coupling. It Must Be Fabricated Out Of Ms Strips Of Suitable Size And Length.B ) The Job Includes Providing And Fitting Of Appropriate Size Ms Nipple 2 Feet Long Threaded On One End And Welded To Same Size Ms Flange Ofthickness ( As Per Table-17 ) At Other End For 80 Mm Diameter Column Pipe As Per Site Requirement. The Threaded Portion Should Be As Per Size Of Pumping Out Let For Proper Fixing.The Job Includes Providing And Fitting Of R. I. Cloth Joints / Rubber Washers With Nuts, Bolts And Washers For All Joints Of Column Pipe. The Job Also Includes Lowering Of Pumping Unit In The Well Then Proper Testing And Commissioning Of Pumping Unit On Full Load At Site.Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. 3 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units.The Body And Bonnent Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions Rest Specification As Per Cluase 12 Of Sbd. 4 Providing And Fitting Of 100 Mm Dia Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) .Rest Specification As Per Cluase 13 Of Sbd. 5 Fabrication, Providing And Fitting Of 100Mm Dia Washout Tee / Y Junctionwith Arm Length 1.2 Feet Each. The Tee Shall Be Fabricated Out Of G.I C-Class Pipe With M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends. 6 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricatedout Of 14 Swg Sheet Having Required Openings / Vents And Protection Class : Ip-55 & Fitted Withaccessoriesmu-G 10 Rest Specification As Per Cluase 43 ____ Of Sbd. 7 Providing, Fitting, Testing And Commissioning Of Voltage Stabilizer As Per Specifications Below:Type Of Voltage Controller: Manually Operated Copper Wound, 3-Phase, Ac Power Supply Multistep.Type Of Regulator : Double Plate Type With Electrolytic Copper Contacts.Input Voltage : 250-400 Volts. ( 3 Phase ) Output Voltage : 400 ±10% Volts.Frequency : 50 ±3 C / S.Windings : Electrolytic Grade Copper Of Adequate Section, Vacuum Impregnated And Rest Specification As Per Cluase 44 Of Sbd.Rating: 50 Kva 8 Providing And Fitting Of 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connections Terminal Shall Be Fitted With Copper Thimbles Of Required Size. The Main Specification Of The Cable Is Given Below: Rest Specification As Per Cluase 47 Of Sbd.Size: 10 Sqmm 9 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size : 80 Mm Dia , Length : 2000 Mmback Fill Compound : 30 Kg 10 Supply, Installation, Testing & Commissioning Of 1000 Va Full Sine Wave Power Inverter ( Make: Reputed ) Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. ( Make: Reputed ) With 2-Core 6Mm2 Cu Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 11 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Belowshall Be Of Providing Of Tool Kit Consists Of Following Itemsi. Double Ended Spanner ( Chrome Plated ) 02 Sets Complete Ii. Double Ended Ring Spanners Chrome Plated 02 Sets Completeiii. Allen Key Set Black Finish 02 Sets Complete Iv. Combination Pliers Insulated With Thick C.A Sleeve; Size In Mm 165, 210, 255 Each – 02 No. V. Long Nose Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Each – 02 No.Vi. Side Cutting Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 Make – 02 No.Vii. Insulated Screw Driversblade Length In Mm Blade Dia. In Mm Tip Dimensions In Mm Quantity50 3 1.6 X 0.4 02 75 3 1.6 X0.4 02 100 3 3 X 0.4 02125 3.5 3.5 X 0.5 02150 3.5 3.5 X 0.5 02 200 4 4 X 0.6 02 300 5 5 X 0.8 02Viii. Hammer With Handle Weight – 110 Mg, 340 Gm , 600 Gm –Each – 1No. Ix. Heavy Duty Pipe Wrench Length In Mm - 200, 300, 600 Each – 01 No.X. Electric Multimeter=1No Xi. Digital Multimeter – 1No.Xii. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xiii. Hack Saw Frame With Hack Saw Blade – 01 No.Xiv. S-16 Mxl, S- 16 H X L Socket Set ( 19 Sockets + 6 Accessories ) – 01 No. 12 Fabricationof6’ X 6’ Angle Iron Bed By Way Of Providingand Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 13 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos Including Cutting, Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 14 Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’S Iv ) Single Bed Warm Blankets With One Sided Fur- 02 No’S The Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patella ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo-Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks 15 Providing & Fitting Of Lighting Points In 1.5 Mm Sq. Multi Strand Pvc Wire As Conductor To Be Laid / Carried In Pvc Channel / Conduit As Per Site Requirement. The Job Also Includes Providing And Fitting Of 5 Amp. Switch Button / Angle Holders To Be Fitted With 15 Watt Ledinside The Pump House. 16 Providing & Fitting Of Heating Points In 2.5 Sq. Multi Stand Conductor To Be Laid & Carried In Pvc Channel / Conduit As Per Site Requirement. The Job Includes Providing And Fitting Of 16 Amp. Switch Socket Combine 17 Providing And Fitting Of 18 Sweep Seiling Fan Of Standard Make Including The Cost Of All Cables , Connections , , Controlsystem Along With The Speed Regulator With Control Switches For The Power Supply 18 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 19 Providing Of Bamboo Ladders 18 Feet Long Along With 15 Feet Long Link Rods And Ht Glove Pair ( 01 No Each ) 20 Providing Of 1 Kw Heat Convector For Operators For Winter Season. 21 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metal Showing The Names Of Water Supply Scheme And The Department.Size:6’×1’6” 22 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site.Size: 4’×6’ Out Ms Angle Of 40X 40X 5Of 36 Rft And Ms Sheet Of 1 Mmthicktotal Weight Of50.16 Kgs 23 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 150Mm, Top 75Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating Having Inside Arrangement For Providing Of Power Connection Along With Following Items. 1 ) 3 Way Terminal Connector 20 Amp.2 ) 3 No Mcb 8 Amp.Rest Specification As Per Cluase 50 Of Sbd. 24 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole Vide Item No.36 Having Following Specs:Input: 90-240 V 50 Hz Power Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170° Lumens: >12000Operating Temperature: -20°C To 60°Crest Specification As Per Cluase 51 Of Sbd. 25 Fabrication Of Gantry Mechanism By Way Of Providing Structural Steel In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 26 Earth Work In Excavation Required For Installation Ofgantry Mechanismand Associated Worksby Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed In All Kinds Of Soil. 27 Providing And Laying Of Soling Stone 28 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With 1: 2 : 4 ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) . 29 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Foundation, Footings, Bases For Columns 30 Painting Of The 2 No. Gantry And Plate Form Of Wellusing One Coat Of Red Oxide Metal Primer And Two Coats Of Enamel Paintof Different Shades 31 Providing, Installation Andtestingof Manual Type Triple Spur Gearchain Pulley Block Along With Monorail Gearedtravelling Trolleyhaving Following Features Capacity=2 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mdetailed Techinical Specification As Per Cluase 24 Of Sbd 32 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 33 Providing & Fitting Of Dozing Pumps To Doze Required Quantity Of Alum / Chlorine In The System. The Capacity Of The Dozing Units Shall Be 0-12 Lph Capacity. Dozing Pups Shall Be Provided With All Required Accessories Including 200 Ltrs. Pvc Tanks And Cable For Connection. Each Pump Shall Be Provided With 20 Mtrs. Cable As Per Required Specification. 34 Providing And Fitting Of Pressure Gauges With Adopters To Replace Damaged Ones .These Pressure Gauges Should Be In The Range Of 0-50 Kgf / Cm / Sg And Bereputed Make. 35 Removal Of Choked Filter Media From 5000 / 6000 Gph Pressure Filter Vessel. The Job Includes All Loads And Lifts, Disposal Of Choked Media To Dumping Site Outside The Premises Of The Plant Within A Lead Of 5 Km. The Vessel Needs To Be Cleaned Properly And Dried Before Laying Of Fresh Media.Providing And Laying Of Filter Media Of Specific Size And Grade To Be Laid In 5000 Gph Pressure Vessels ( 02 No ) Duly Washed, Free From Dust , Dirt , Loom And Any Other Inorganic Materialor Suspension .The Job Includes Carriage Of Filtermedia From Ganderbalto Site Including Allall Loads And Liftsrequired On The Site Condition. The Media Is To Be Lad In Different Layers Of Specific Size And Grade From Bottom To Top Over The Filter Bed Plate. The Bottom Layer Is To Be Laid Without Tilling / Damaging The Pressure Nozzles. Providing And Fitting Of 12 Mm Dia. Fine Threaded Pvc Nozzles Auxiliary Type To Be Fitted On Filter Bed Plate Of Pressure Vessels ( 02 Nos ) . Providing And Fitting Of 29 Inch. Dia. Rubber Washers / Gaskets For Manhole And Inspection Chamber And Opening Of Pressure Filter Vessel.Providing And Fitting Of 3”X5 / 8” Nuts And Bolts.Overhauling Of Backwash Unitof 5000 Pressure Vessel ( 02 No ) By Way Of Dismantling Of Unit Parts Assembling Cleaning, Oiling, Greasing, Replacement Of Any Damaged Parts, Refining Of Sub Assemblies & Installation Of Backwash Unit With Its Existing Suction & Delivery Outlet. Job Includes P / F Of Packing & Consumables. Painting With Synthetic Enamel Paint Two Or More Coats Of Approved Brand And Bar Pressure Clarifier Pressure Filter Vessel, Fittings And Complete Piping After Cleaning Of Dirt By Kerosene Oil And Application Of Steel Primer Of Specific Grade.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Jammu And Kashmir View Result →
15.
Educational and Research Institute #10265178 Price Bid
Tender For Clean Room; 1 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-50 mm thick PPGI/ PPGIWall panel for coloumn 2 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-100 mm thick PPGI/ PPGIWall panel for coloumn 3 Wall paneling of PPGI/PPGI of 100 mm thick with 40 mm of glass wool panel, Desnity 100Kg.M3, Non combustable, Penling color as per architect choice. With necessary double door of equal size as per site condition. Fittings complete all. Panel of three side with roof necessary duct cut otu with proper seal to be done as per site for sound insulation. 4 Panel Thickness : 100 mm PPGI/PPGI Wall raiser ( 700 width x depth less than 80 mm) 5 WALKABLE CEILING PANELS PPGI/PPGI -Double skin modular clean room walkable ceiling panels made With 0.6 mm Pre coated sheets on both side with PUF as infill of density of 40 ± 2 Kgs/m3. -50 mm thick PPGI/ PPGI CEILING PANELS 6 CLEANROOM DOORS -50mm thick flush frame made of 1.2 mm thick GPSP powder coated sheet, 0.8 mm thick PU powder coated GPSP sheet with HONEY COMB KRAFT PAPER as infill of 46mm thk shutter suitable for 50mm thk frame, including all the accessories like double glazed veiw glass, hardwares like push plate, kick plate, non concealed door closure. SS D handle, SS ball bearing butt hinges, both side key operated lock & key. Concealed drop seal per leaf and concealed flushbolt for double leaf door etc.- Single Leaf Door - Size 1000 x2100 mm 7 Double Leaf door size 1800mm x 2100 mm 8 Double Leaf door size 2000mm x 2100 mm 9 VIEW PANELS -Double glazed view 5 mm toughned glass with flush design, 50 mm thick flush view panel made of 1 mm thick GI frame with PUF as infill in- between the frame. 10 Coving & Corners -Male & Female R-70 Powder coated coving 11 2D / 3D internal powder coated corner coves 12 External 90 degree powder coated coving 13 Bottom Track for panel 14 Silicon sealent for panel to panel joint 15 Supply, installation of Air shower- Microflow make MFD-AS -1200 Model. Inner dimension- 900x1220x1950 (H), Over Dimension of -1800x1320x2200(H), Cabinet, Platform Stainless Steel-304, of 1 person capacity, GI Powder coated with flush double glazing , hardware like door closure, D handle, ball bearing butt hinches door with vision panel, pre filter - flange type of 90% efficiency, pressure drop -6 to 8 mm, Hepa filter Box type, 00.007 % efficiency, pressure drop of 25 mm of W.c, Adjustablke nozzle of 30mm, As per manufacuter specification ,Control motor by DOL starter, doors by electronmahnectic inter locking, Overload protection, thermal relay,Emergency off- Push button. complete all. consider Micro flow 16 Design , supply, providing of ESD MAT flooring of Homogeneous composition with block conductive layer sandwhich between two antistatic layers. Of BS 2050 /1978IS 3462 /1986 Governing specification. Thickness of the materials 2 mm +/-0.1mm( 0.5mm sandwhich conductive layer), Electrical propertie : Surface resistivity 108 -1010ohms/sq. Decay time: Less than 2 seconds. including copper strip below mat to connec the earth bus complete all. with an thermo welding process complete all. 17 Panels as per technical specifications & schematic diagram. 18 Supply, Installation, Testing and Commissioning of Indoor typeLTSwitchboards, Floor mounting type, Bottom/Top entry. Refer enclosed SLD.Enclosure: Compartmentalized Single front CRCA (Cold rolled Cold Annealed sheet steel) Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mmIP class for Indoor/IP55 with weather proof enclosure for outdoor Bus bars: Electrolytic grade conductivity as per standard IS 5082Bus bar Material: As per SLD Bus bar joints: Shrouded/TinnedProtection releases: As per SLD (Adjustable over current & short circuit unless otherwise specified)Ics=Icu for all breakersUtilization category: All MCCB/ACBs shall be Cat: A except ACBs for Ltg & raw power input distribution panel shall be with Cat: FORM 4B Loovers: Busbar chamber shall have louvers with fine mesh insideShade: Epoxy powder coated RAL 7032Design: Modular type Cable entry: As per site conditionBus bar insulation: Aluminum bus bars shall be bare with color coding at the ends/Copper shall be bare with color coding at the ends/For Humidified areas the copper bus bars shall be coated with tin. 19 Note: The Panel shall be fully as per the requirement of Electrical Inspectorate/ EB authorities. Auxilliary contactor to be provided along with auto-manual switch where ever required.All MCCB Breakers both Incoming & Outgoing shall have LEDON / OFF / TRIPindications without fail. CTs shall be with dual ratioand cast resin type only. All doors to have double rubber gasket with shutter assembly & door seating frame.All AC feeders will have time delays of 0-60 Seconds. MCCBsof 250A Above willbemicroprocessor basedonly. Any panel if more than 1.5m width should be made in parts each part not exceeding 1.5m. The current density for Aluminum busbars shall be 0.8 only.All UPS outgoing panels shall haveneutral busbars double the size of phase. All MCCBs shall have plug setting from (40or50)-100%.All Lighting / RP and Lift panels shall have ELR for incomer of Prok. Dvs. Make only. All test certificates must be provided immediately after commissioning.SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED FROM CEIG. All meters shall beDigitaltype only. FRLS PVC copper wires shall be used for control wiring 20 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :Main panelsupply, installation, Testing and Commissioning of Main Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 315A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –315/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-315A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 5 Nos - 63A TPN MCCB, 1 Nos - 40A TPN MCCB, 2 Nos-250A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 400A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 V Construction :Single Front with Top Cable EntryDimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout. 21 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :CLEAN ROOM PANELsupply, installation, Testing and Commissioning of Clean Room Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 250A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –250/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-250A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 2 Nos - 125A TPN MCCB, 3 Nos-40A TPN MCCB, 3 Nos-25A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 250A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.Voltage :415 V Construction :Single Front with Top Cable Entry Dimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout 22 Servo Stablizer 80Kva 3PHASE STABILIZERSupply and Fixing Three phase full automatic compensation AC voltage servo stabilizer is 80kVA capacity, 3 phase 4-line with 175V-265V (phase voltage) / 304V-456V (line voltage) input voltage range, the default output is 3 phase 380V, other voltages are customizable. ±15% tolerance of input range for output voltage above 380V and ±20% of that below 380V. 23 Switch Board Designation : UPS OUTGOING PANELsupply, installation, Testing and Commissioning of Ground Floor Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485. INCOMER:- 1 Nos – 125A TM TP+2N MCCB 25 KA. 1 Sets –LED type RYB indication lamp with control MCBs,1 Sets –LED type ON/OFF indication lamp with control MCBs.OUTGOING:- 6 Nos - 40A 10 kA TP+2N MCB, Spare Refer SLD BUS BAR RATING:One set: 125A3phase + Double Neutral 25KA for 1 sec. Cu. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 VConstruction :Single Front with Top Cable EntryDimension : To be assessed by Contractor.Location : Refer Electrical Equipment Layout 24 DISTRIBUTION BOARDSLDB - 8 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following :INCOMER: 40A TPN MCB 10kA with all necessary connected accessories – 1No.32A DPMCB WITH 32A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 32A DP RCBO outgoing consist of 8nos.610 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 25 UPS - 12 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 12way MCB DB comprising of the following :INCOMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No.40A DPMCB WITH 40A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 40A DP RCBO outgoing consist of 12nos.1620A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 26 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided.,4 Core 150 Sq.mm XLPE Aluminum armored Cable 27 4 Core 120 Sq.mm XLPE Aluminum armored Cable 28 4 Core 95 Sq.mm XLPE Aluminum armored Cable 29 4 Core 25 Sq.mm XLPE Aluminum armored Cable 30 4 Core 16 Sq.mm XLPE Aluminum armored Cable 31 4 Core 6 Sq.mm XLPE Copper armored Cable 32 4 Core 4 Sq.mm XLPE Copper armored Cable 33 3 Core 6 Sq.mm PVC Copper armored Cable 34 3 Core 2.5 Sq.mm PVC Copper Cable 35 3 Core 1.5 Sq.mm PVC Copper Cable 36 1 Core 25 Sq.mm PVC Copper armored Cable 37 1 Core 1.5 Sq.mm PVC Copper Cable 38 1 Core 2.5 Sq.mm PVC Copper Cable 39 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided., 4 Core 50 Sq.mm XLPE Aluminum armored Cable 40 4 Core 35 Sq.mm XLPE Aluminum armored Cable 41 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits consider Dowells / Comet (copper sockets for copper cables and Alu. Sockets for alum. Cable)4 Core 150 Sq.mm XLPE Aluminum armored Cable. 42 4 Core 120 Sq.mm XLPE Aluminum armored Cable 43 4 Core 95 Sq.mm XLPE Aluminum armored Cable 44 4 Core 25 Sq.mm XLPE Aluminum armored Cable 45 4 Core 16 Sq.mm XLPE Aluminum armored Cable 46 4 Core 6 Sq.mm XLPE Copper armored Cable 47 4 Core 4 Sq.mm XLPE Copper armored Cable 48 3 Core 6 Sq.mm PVC Copper armored Cable 49 1 Core 25 Sq.mm PVC Copper armored Cable 50 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable) 4 Core 50 Sq.mm XLPE Aluminum armored Cable 51 4 Core 35 Sq.mm XLPE Aluminum armored Cable 52 WIRING - CIRCUIT CUM POINT WIRINGThe rates for all point wiring items shall also includesupplying and fixing of the Conduits,conduitspecials, bushes and other fittings,Approved GI saddles and grouting thesame for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto connectorviaswitch and shall include thecircuitwiring also except where identified. 53 Primary Light / Fan Point Wiring: Supply, wiring, connecting& commissioning of 3Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with molded front plate in GI anodized manufacturers mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit 54 Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point. 55 SOCKETS Supply, Installation, testing and commissioning of 1nos 6/16AUniversal switched socket( UPS) and 1nos 16A switches and withmolded frontplate, GIanodized enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points. 56 Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.). 57 Cat6 RJ45-RJ45 UTP Patch Cords, color matched, Yellow - Workstation end, 7 ft, Data-1 58 2-port Faceplate 59 4-pair, Cat6 UTP Cable, roll of 305m, LSZH 60 Cat6 24-port Unloaded Angled Jack Panel, 1U 61 Cat6 UTP Information Outlet for Jackpanel end 62 LIGHT FITTINGSSupply, Fixing, testing and commissioning of square type Recessed mounted LED luminaire 42 W (W)600x600 with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 63 EARTHING Supply, installing, testing and commissioning of maintenance free earth pipe of 3 mtr long T50 mm dia dual G.I pipe with flat buried in ground with back filling compound in an earth pit of 450 x 450 x 3000mm mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. A masonry structure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 64 Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mmcopper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonrystructure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 65 Supply andlaying of following copper flats laid in open / buried underground / concealed manner withnecessary clamps, SMC insulators, screws, interlinks etc. for earthing . 50X10 mm GI . Flat for panel cable tray Body earthing 66 25X6mm GI . Flat for panel cable tray Body earthing 67 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required 68 8 SWG Cu. Wire for DBs earthing 69 25X6mm Cu Flat forearthing 70 SECTION-A : UPS / INVERTER SYSTEMSupply, installation, testing and commissioning of 3 kVA Inverter system with single phase input and single phase output with Battery stand complete all necessary accessories and tools as required as per site condition. Make : Schenider , Socomec 71 Supply, installation, testing and commissioning of 3x25KVAonline modular UPS System Three phase input & Three phase output, 50 Hz, 415 V complete. The UPS shall be microproccesor based online with IGBT based convertors (Rectifier & Inverter) and with automatic static by pass.The UPS system shall be provided with SMF batteries (including all the necessary accessories like racks/cabinets, interconnecting links/cables, battery circuit breaker etc.) with 20 minutes back up for each UPS, and communication interface. Quoted rates should be inclusive of Base Frame for the UPS with height of 300/450mm, Load testing (resistive load bank) for four hours/UPS with all necessary items. Supply, Installation testing and commissioning of 1No. of 3 Phase 75KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Supply, Installation testing and commissioning of batteries for 30 mins back up at 75KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between battery bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery Rack for the above said batteries with all required accessories. (battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 60KVA load) 72 Supply, Lifitng , Positioning , Installation, Testing and Commissioning Air cooled Inverter modular Chiller with Dual Circuit , EEV Precise Electronic Expansion valve, High efficiency PlateHeat Exchanger stainless steel plate, low water pressure drop, Smart control with touch screen for heating and cooling system, High Precision stepless energy modulation trane variable frequency unit, High efficiency fan design, Refrigerant R410A, Cooling capacity 130KW, Power input -38.1, Cooling 7DegreeC / 12 Degree C, COP(AHRI)- 3.41, IPLV-4.81, Compressor -2 Nos, Air flow- 23500x2 Nos, Water flow rate- 22.4 Cum/Hr consider Trane., Blue star, Samsung with necessary control panel isolator spring, complete all. 73 CHILLED WATER Primary PUMPS Supply and install of Design envelope close coupled vertical in-line pump in-built VFD with logic controller. Series Design Envelope Sensorless The pumps shall be radially split, single stage centrifugal type with Bronze fitted casing with equal size suction and discharge flanges and having separate tapped flush line and pressure gauge connections,dynamically balanced Bronze impeller, stainless steel shaft lower carbon throttle bushing, outside balanced type mechanical seal with carbon rotating face, Silicone carbide stationary seat Viton secondary seal.The pump motor shall be suitable for 415V+/- 10% Volts, 50 +/- 5% Hz, +/- 10% combined voltage and frequency variation, 3 phase AC power supply. The squirrel cage induction type, P base with TEFC enclosure ansd shall be connected the pump through a high tensile Aluminum slit type spacercoupling to permit servicing of the mechanical seal without disturbing pump, motor or electrical wiringconsiderKSB, Armstorng, Grundfos. Coupling shall be protected by a motor. Flow Rate GPM 100( 2 Working + 1 Standby ) of 32m head. 74 CHILLD WATER SYSTEM AHU Supply, Installation, Testing and Commissioning of vertical floor mounted double Skin AHUs Withmm Sand witched PUF Insulation,top discharge Fan with TEFCmotor, 12 row chilled water coil,pre filter section with filters of 90% efficiency down to 10 u,Limit Switch, Emergency Light, Guard for Inspection Door, Commissioning filters set, outlet damper, etc. of the following capacities with VFD starter panel complete all. including vibration pad etc.Extruded Aluminum Aero foil blade low leakage manual Fresh air damper. Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Pre Filter Section Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Cooling Coil Section8 Row Deep CHW Type coil (Cu Tube & Al fins). To achieve the 22 Degree If any changes coil row to be increased. SS 304 Insulated drain pan with Nitrile Rubber Insulation. BLOWER SECTION EC Fan top dischargeBLEED FILTER SECTION Flange type washable bleed filter 3 micron EU7 Grade at Bleed air outlet with Extruded Aluminum Aero foil blade low leakge manual bleed air damper.FINE FILTER SECTION . Flange Type washable Fine filter 3 micron EU7 Grade with frame. consider CVR Aircon, Air Prism tech, Thermoflex SUPPLY SECTION WITHExtruded Aluminum Aero foil manual volume control damper at supply & Return air outletDuct mounted heater .Magnehelic gauges for measuring differential pressure across AHU filters. Silicon tubes, necessary fixing accessories , screws etc. To avoid vibration on floor vibration isolation should be provided. classified area- 100000 class- 22 degree c , 50% RHAHU Capacity - 8000 cfm Fan static pressure in mm of wc-100Cooling capacity - 13.0 TR 75 Duct mounted heaters Supply, Installation, testing and commissioning of Duct mounted heaters with thyristor control. Cost shall be including of control panel with necessary temperature and RH sensor to control the heater complete all. Etc.-20 KW heaters( Can be spited as per required) for each units 76 AIR CURTAINSAir Curtains with wall mounted type, robust construction, powder coated finish, Aluminum impellers with low noise forward curved blades, adjustable louvers, vibration free operation, pre-lubricated both side sealed ball bearings for smooth running of Air curtain. The Air curtains are should be interlocked with door limit switch.Size: ( 2000Lx300Dx300H) 77 Size: ( 1000Lx300Dx300H ) 78 FRESH AIR UNITS Supply & Installation of Modular type Floor mounted Double skin FRESH AIR FILTER MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panel with 0.63mm GI inner & 0.63mm pre coated GI outer skin. It comprising of filters section with flange type 20 micron filters down to 80% efficiency, consider Kruger ,Greenheck, Carryaire.KRUGER NICOTHRA, higher quality DIDW BLOWER with CG /Higher make non FLP IE-3 motor. Aluminum aero foil design volume control damper with operating knob handle.-5000 CFM. 79 VENTILATION AIR UNITSSupply & Installation of Modular type Floor Mounted Double skin ventilation AIR FAN MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panels with 0.63mm GI inner & 0.63mm pre coated GI outer skin. KRUGER/NICOTHRA / Higher Quality MAKE DIDW BLOWER with CG /Higher Quality make non FLP IE-3 motor, consider Kruger ,Greenheck, Carryaire.Aluminum aero foil design volume control damper with operating knob handle.-4000 CFM. 80 AIR DISTRIBUTION SYSTEM Supply, installing, testing and commissioning of following items as specified and shown on the drawing for complete and satisfactory operation and control and to local authorities approval. Air distribution system consists of factory fabricated sheet metal rectangular ducting with reinforcement / stiffeners (manufactured through computer aided machine which has automatic provision for plasma cutting for the profiles and for auto folding) with TDF /TDC flanges, nuts and bolts, corners, clipsetc with suspenders with Gripple /Zip Clip cables, complete as per specification. consider Cosmic , Western air duct , Sreevinus The ducts shall be fabricated as per SMACNA standards. 18G thick GSS ducting– factory fabricated . 81 20G thick GSS ducting – factory fabricated 82 22G thick GSS ducting – factory fabricated 83 24G thick GSS ducting – factory fabricated 84 Supply, fabricating and erecting structure steel of make TATA/SAIL shall be confirm to IS:2062 along with test certificate as per specification including transporting, straightening, cleaning, fabricating and erecting various structures in position for ducting support, applying two coats of zinc chromate primer of ICI, Asain make or equivalent, with rubber gasket between support & duct as per specifications and drawings and as directed by the Engineer-in-Charge client /consultant. 85 Supply and erection of Nitrile rubber Insulation of Supply air duct with 19mm thick Armasound cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification.- Return air duct 86 Supply and erection of Nitrile rubberInsulation of supply air duct with13mm thick, FM approved cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification. 87 Supply and fixing of Spigot damper shall be installed from take off collar to diffuser plelum boxes(low leakage) consider Cosmic, Western air duct , Sreevinus,made out of 1.6mm galvanized sheet steel frame and blades of 1.0mm galvanized steel with suitable links. 250mm dia 88 100mm dia 89 Supply and installation of Flexible duct connections between main duct and diffuser plenums, Consider Cosmic , Western air duct , Sreevinus, shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports.250mm dia. 90 Supply and installation of Powder coated extruded Aluminum linear grills for supply air grills Consider Cosmic , Western air duct , Sreevinus .The rate shall inclusive of Aluminum with collar damper, necessary fixing and supporting arrangement for the grilles. 91 Supply and installation of Powder coated extruded Aluminum linear grills for return air grills consider Cosmic , Western air duct , Sreevinus.The rate shall inclusive of Aluminum with out collar damper, necessary fixing and supporting arrangement for the grilles. 92 Supply and installation of GI volume controldamper, (low leakage) made out of 1.4mm thick galvanized sheet steel frame and opposed blades of 1.4mm galvanized steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system consider Cosmic , Western air duct , Sreevinus. Rectangular type VCD -for future provision classified room damper to be provided. 93 Supply, installation of 4 way diffusers for Return air of neck size 550x550 94 SupplyFabrication , and erectionofDouble canvas connection made out of fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc 95 Terminal HEPA Filter Module (For ISO-7 & ISO-8 areas) Terminal HEPA filter module of GI powder coated sheet construction with volume control damper (shall be operated from the clean room), DOP test port, Mini-pleat HEPA filters with 99.97% efficiency, swirl type air diffusers at terminal level .HEPA Filter Size: 600 x 600mm / each up to 1000cfm 96 Supply and Fixing -UL 555 listed Moto raisedFire damper with 300mm sleeveDampers G.I.16G. The fire dampers of atleast 2 Hours fire rating with angle frame (on both sides of wall) and multi leaf dampers out of 18G with cross bush.The dampers to signal accidental closure through built in limit switch. Include for hard wiring between starter and Limit switch, including necessary Bolt, nuts & supports. 97 Supply, installation, testing and commissioning with belmo activator with necessary cables , control panel, to connect with AHU starter panel to control the fire mode. 98 Supply, laying & termination of 3C x 1.5Sq.mm power cabling between 230V single phase power socket to Actuator with necessary supports & clamps. 99 Supply & fixing of 16G M.S.Conduit for cable laid between actuator to AHU panel 100 MS PIPING Interconnecting MS with c class pipe work duly insulated with elastomeric nitrile rubber typetubular insulation as per specifications .All piping inside the room shall be properly supported with hanger.MS supports for piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. 100 mm dia 101 80 mm dia 102 65 mm dia 103 Supply, installation of nitrile rubber insulation with Aluminum cladding of 26 Gauge complete all. 104 DUAL PLATE CHECK VALVES :( NRV )Supply, installation, testing & commissioning ofdual plate check valves, wafer type sleep-on construction.The valve bodyshall be cast iron as per IS 210 Gr. FG 220. The valve disk shall be aluminum - bronze plate, SS 316 inch pins & pins and springs rubber seal and should be rated for a pressure rating of ANSI 150and complete with with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification. 50 mm dia 105 Y-TYPE STRAINER :Supply, Installation, Testing and Commissioning ofY – Strainers CI fabricatedcomplete with SS - 304 perforated sheet basket having 3 mm perforated hole, PN-16 pressure rating body,Tabel-E flanged endsand duly insulated as per piping and specs.65 mm dia 106 BUTTERFLY VALVES : Supply, installation, testing & commissioning of Wafer type Butterfly valves with PN 16 pressure rating, Cast iron body , EPDM Seal, Stainless Steel 416 Shaft material, Nylon coated ductile iron lever lock handle and confirming to IS:13095, complete with companion slip on flanges as per BS10, nuts, bolts and gaskets as required.with 30 mm thick PUFwithAluminum claddingthickness of 22G.50mm Dia 107 65mm Dia 108 PRESSURE INDIPENDENT BALANCING AND CONTROL VALVE - PIBCV:Supply, Installation, Testing & CommissioningofPressure independent balancing cum flow control valve PN16, Cast Iron body with flanged end with modulating type electronic actuator, solid state temperature sensor and controller, power and control wiring, power supply unit etc. consider Donfos / Honeywell / Siemens.The valve actuator and sensor shall be IBMS compatible. with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification 80 mm dia . 109 PRESSURE GAUGES : Supply, Installation, Testing and Commissioning ofdial type pressure gauges made of Stainless steel with range selected so that normal operation is near to middle of the scale, consider Wari/ H guru.Syphons and cocks to be provided along with SS snubber. 110 DIAL TYPE THERMOMETERS : Supply, Installation, Testing and Commissioning ofdial type Dial type Thermometers of 100 mm dia shall be of mercury in steel type with range suitable for the temperature services.It should be installed in the thermowells as explained in the tender specifications.. 111 DRAIN VALVE :Supply, Installation, Testing and Commissioning of Ball Valve for drain with insulation. Nipple and dummy to be fixed after the gate valve of size 25 mm NB. 112 AUTO AIR VENT VALVES : Auto Air valves to beprovided at all high points in the piping system for venting. Valves shall be of the double float type with G.Mbody, vulcanite balls, rubber seating, etc. of 20 mm NB and shall be associated with an equal size gate valve with rising spindle. 113 Ball VALVES : G.Mbody, vulcanite balls, rubber seating, etc. offollowing size inmm NB and shall be associated50mm Dia. 114 25mm Dia 115 Leakage test for DuctingAll medium and high pressure ductwork at classified and unclassified area shall be seal class A and be leak tested as per IS-655.2006 leak test method Class-6 (rectangular duct) & soap solution.This has to be carried out through third party agency not the vendor. 116 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.1% duct vol/min at 1000 Pa (4 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 117 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.2% duct vol/min at 500 Pa (2 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 118 VALIDATION & DOCUMENTATION Validation including DQ, IQ, OQ & PQ protocols and certificates of all manufactured items, duct. Validation should include minimum following tests:- i) Air quantity, Air flow velocity and ACPH calculation ii) Pressure balancing iii) Filter leak test iv) Particle count test v) Recovery test vi) Air flow pattern vii) Temperature & RH monitoring for 3 days by data logger. Validation should be conduct for all three seasons (Three times / year) Immediately after commissioning, one validation after 6 months of system running and final validation at the end of guarantee period.Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 119 Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 120 FIRE EXITINGUISGHERS:- Portable ceiling mounted clean agent fire extinguishers manufactured as per IS with ISI marked suitable for wall mounting / floor mounting / trolley types with all accessories. -10kg with necessary ceiling mounted brackets up to the ceiling height maximum of 1200mm as per site condition, consider Safex, Ceasfire, Minimax. 121 4.5 kg. capacity carbon di-oxide fire extinguishers with wall mounting bracket 122 SITC OF SIGNAGE SYSTEM -FIRE EXIT - SINGLE SIDE 123 DIRECTIONAL EMERGENCY EXIT (AUTOGLOW SIGNAGE) - DOUBLE SIDE Make : Prolight 124 EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side 125 MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side 126 Fire Evacuation Route Map as per following specification Evacuation plan shall be glow in dark. A3 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports. 127 ADDRESSABLE FIRE ALRM SYSTEM -Supply, Installation, testing & commissioning of 2 Loop Addressable Fire Alarm Control Panel - Total 640 Devices per loop 159 detectors/ 159 modular combination, consider Edwards Honeywell, Ravell 128 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector above with necessary base box complete all. 129 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector below with necessary complete all. 130 Supply, Installation, Testing and Commissioning ofResponse Indicators. 131 Supply, Installation, Testing and Commissioning of Addressable Manual Pull Station . 132 Supply, Installation, Testing and Commissioning ofSounder Cum Strobe . 133 Supply, Installation, Testing and Commissioning ofAddressable Short Circuit Isolator Module 134 Supply, Installation, Testing and Commissioning ofAddressable Control Module. 135 Supply, Installation, Testing and Commissioning ofAddressable Monitor Module . 136 Supply, Installation, Testing and Commissioning ofJunction Box. 137 Supply & Laying of 2C X 1.5 Sq.mm Shielded Copper armored Cable, including clamps, fixing accessories complete all. 138 Supply & Laying of 4C X 1.5 Sq.mm Shielded Copper armored Cable,including clamps, fixing accessories complete all. 139 Supply, Installation, Testing and Commissioning of power supply unit 140 4 reader controller with cabinet and power supply backup. as per specification. 141 Multitech T15 reader 142 Supply, Installation, Testing and Commissioning of surface / flush mounted (as required at site) Magnetic Contact (Door position sensor)for access controlled doors as per the tender specification. 143 Supply, Installation, Testing and Commissioning of exit switch & accessories with 2.5mm thick SS front plateas per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories. 144 Supply, Installation, Testing and Commissioning of Buzzerfor access controlleddoors as specified inthe Tender Specifications 145 Supply installation, testing, commissioning of EDR (EMERGENCY BREAK GLASS) 146 Supply andlaying of 4 core 1.0 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller to Lock & door position sensors, Buzzer,BGU,Pushbutton as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 147 Supply andlaying of 8 corex 1 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller toreaders as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 148 Supply andlaying of 2 corex 1 Sq mm Un armored Shielded FRLS, Multistanded Copper Conductor, PVC sheathed Cable Rate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. (conduits & cables - blue color) 149 Supply andlaying of MS Powder coated Trunking 150 x 50 mm x 2mm with cover &fixing suppports etc as required 150 Supply andlaying ofCAT6 cable in PVC FRLS Conduits (this item inclusive of necessary patch cords,I/Os& terminations ) - for connecting Controller/Reader with IP switch 151 Supply, Installation, Testing and Commissioning ofLocal scare alarm with required wiring between LCA & door contacts (For fire exit doors). 152 VIDEO SERVILANCE SYSTEM - Supply, installation, testing and commissinoning of, 5 Megapixel low light power over -coax(PoC),Dome type HD Output, up to 720 P resolution, Low illumination, 3.6mm lenss, tru day / Night , OSD menu,Smart IR, Up to 40 m IR Distance, necessary suports, complete all.consider Hivision, Dohua, Honeywell. 153 Supply & Installation of Network Video Recorder with 8 HDDs Storage Capacity, 32-Channel Video, Client Licenses, & supports H.264 Compression, Real time Surveillance, The data should be stored 90 days (Hard disk to calculation report to be submitted). -8 TBHard disk which ever is to be check 154 Supply, installation, testing and commissioning of 42 Inches HD LED Television (TV)/Moniterwith Resolution: 1366 x 768 Pixels and 2 HDMI out put. With necessary power cable complete all. 155 Supply, installation , testing and commissioning of PYE swith ( Power on Ethernet) with necessary arrangement complete all. 156 Supply, installation of Cat 6 cable with 25 mm PVC conduit with necessary L, bend, flexible conduit , clamps complete all. 157 Supply and laying of 2Cx 1.0 Sq.mm FRLS cable with suitable accessories etc. 158 Supply and fixing of power supply unit complete all. 159 PLUMBING & SANITARY WORKS: Supply, fixing of 15mm dia Sensor Pillar cock with necessary flanges suitable for under counter wash Basin . Jaquar Make - SNR- CHR 51011 160 INTERNAL WATER SUPPLY -Supply and installation testing and commissioning ofpipe CPCV SDR-11 as per IS 15778including fittings, supports, clamping ,flow indication colour band ,pipe name marking etc complete in all respects. Including wall chasing and finishing the wall in good condition as per original complete all. -20 NB 161 Supply, erection, testing and commissioning of CPVC valve of the following sizes including nipple etc complete in all respects of following sizes. -20 NB 162 Supply, installation of digital type water meter with necessary fixingaccessories complete all. -32 mm dia 163 INTERNAL DRAINAGE SOIL AND WASTE PIPES , INTERNAL- Supplying and laying P.V.C Pipes of 6kg class ofIS:4985 - 2000and P.V.C.Pipe specials of cutting to required length, Erectionpipe specials along with P.V.C.Pipe, Making ring seal couplers to join the pipe and pipe specials. 110mm dia, using internal and external including excavation and complete all. with necessary wall clamps.Internal & External - 110 mm dia pipe -6 kg/cm2 164 75 mm dia pipe - 6 Kg /Cm2 165 50mm dia pipe- 6kg/cm2 166 supply installation of floor drain fabricated as per site condition 167 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 28 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 168 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 20 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 169 LIGHT FITTINGSSupply, Fixing, testing and commissioning of surface mounted type LED luminaire 15 Wlight fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 170 Supply, Installation testing and commissioning of 1No. of 3 Phase 10 KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Note : Vendor to submit filled compliance for both specification sheet & Data sheet . Supply, Installation testing and commissioning of batterries for 15 mins back up at 10 KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between batterry bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery& Rack for the above said batteries with all required accessories. (Each set of battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 10 KVA load). 171 Supply, installation, testing and commissioning of BACNet compatible Ultrasonic BTU meter as per the system requirements for tenant billing. 100 mm dai 172 80 mm dia 173 65 mm dia 174 Supply, Installation, testing and commissioning of Control panel for above BTU meters to control the PIBCV with necessary wiring complete all. 175 Supply, instalaltion of Thermowell of ss as per requirement with insert type temperature sensor complete all. 176 Supply and installation of Flexible duct connections between main duct and diffuser plenums shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports. 100mm dia 177 Air terminals : Supply & installation of Terminal module of 16/18 G GI powder coated material, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob provision should be bottom. Module size: 680 x 680mm or MFD Std. but Suitable for 610 x 610 x 300 / 150 deep 178 Module size: 540 x 540mm or MFD Std. but Suitable for 450 x 450 x 300 / 150 deep 179 SIZE :450 x 450 x 300 / 150 deep 180 SUPPLY AIR GRILLS : Grill size: 745 x 745 mm or MFD Std. 181 Grill size: 600 x 600 mm or MFD Std. 182 Supply grill for IOT Control air vent system for the cleanroom to monitor and control temperature and RH, via mobile or desktop application, damper with neceeary activator, control cabling, as per client requirement. Including conduit clamps complete all. 183 Supply, installation, testing and commissioning of control panel for the above with necessary controller for automatic and manual both options complete all. 184 RETURN AIR MODULES : Supply & installation of Raiser module of 16/18 G GI powder coatedmaterial, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob to Control The Air -Grill Module Size : 540 x 540 x150 mm 185 RETURN AIR RISER GRILLS : RETURN/EXHAUST Air RISER mounted module grills made of SS-304 Mirror polished in front (180 grit) in 16 G Perforatedgrills fixing to the Terminal module ( Grills fixing blind bush suitable to M-6, SS-304 doom bolts). SS 304 grill For Raisers (as per drawing) 186 SS 304grill For Grill Modules 187 RETURN AIR RISER FILTERS: Return/ExhaustAir False ceiling mounted Terminal filters made of 16G GI Powder coated filter Box with flange type casing and 10micron down to 90% efficiency. Filter media shall be SNPF [WASHABLE] -700 x 450 x 20 MM 10 Micron filters and control damper (as per dwg) 188 Supply, Installation, Testing & Commissioning of Piping system with SS 316L confirming to ASTM A 269, Internally electropolished to 10 Ra micro-inch surface finish and ends capped, orbitally robotic welded along the circumferance, properly colour coded as per IS standard with following diameterand wall thickness as noted below with flow arrow, service metal band and colour stickers as per IS standards. Approved make: Sandvik/Sumitomo. 8.0 MM for compressed air as per client requirement and layout. 189 Supply, installation, testing and comissioning ofBall Valvewith Ferrule tube fittingsEnd connection-Swage lock Class- 150#Ball construction- Single Piece, Body- SS316LBall - SS 316LApproved Make: Swagelok -8 mm 190 Supply, installation, Calibrated, and commissioning of SS Buordon type pressure gauge with100 mm dial dia, syphone tube, needle valve and the scale range 0-20 bar. 191 Supply, Installation of 40 NB Digital vertex type flow and consumption meter for Compressed air application. Max flow 124 CFM at 8.5 bar. 192 Supply, Installation of following size of GIrubber line Split clamp. - 8.0 MM 193 Supply, Installation ofGI slotted C - Channel 40 x50x40 2mm thick for compressed Air pipe support. 194 Warranty for all the above items.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
16.
Drinking Water Supply and Sanitation #10210157 Price Bid
Electrical And Mechanical Works To Be Carried Out At Water Supply Scheme Mehjoorabad Mitrigam.-2 Supply, Installation, Testing & Commissioning Ofsubmersible Pumping Unit As Per Is 8034 Withfollowing Specifications .Pump:Efficiency = Not Less Than 50% Speed =2900 Rpmtype Of Pump = Mixed Flow. Type Of Fluid To Be Handled= Water From Tube Welldischarge= 4000 Gph, Head= 50 Metres Material Of Construction:Impeller = Stainless Steelpump Shaft = Stainless Steel Ss 410. Pump Casing= Cast Iron / Stainless Steel Impeller: Impeller Is Of The Enclosed Or Semi – Enclosed Type And Properly Balanced. Enclosed Impellers Equipped With Seal Rings On Their Hubs.Coupling: A Suitable Coupling Arrangement Provided With Pump Set. Non Return Valve: -Non Return Valve Of The Suitable Size Provided Above The Pump Discharge Case. Motor:-Method Of Starting=Star – Delta Speed = 3000 ( Sync ) .Frequency = 50 ± 3 % Hzworking Voltage = 380-415 ± 15% V, 03 Phase Efficiency = Not Less Than 90%Class Of Insulation = F / Suitable For Above Parameters Motorcapacity = As Per Above Requirements. Submersible Motor Should Be Water Filled, Water Lubricated .The Motor Should Be Sealed By Radial Rings To Avoid Mixing Of Well Water With Motor Filled Water. The Job Includes Providing And Fitting Of Interlocking Arrangement Against Any Failure Of Coupling. It Must Be Fabricated Out Of Ms Strips / Rods Of Suitable Size And Length. The Job Includes Providing And Fitting Of Appropriate Size M / S Nipple 2 Feet Long Threaded On One End And Welded To Ms Flange Of 65 Mm Dia, 10 Mm Thick At Other End .The Threaded Portion Should Be As Per Size Of Pumping Out Let For Proper Fixing. The Job Includes Proper Testing And Commissioning Of Pumping Unit On Full Load At Site. Note: Providing Of Test Certificate & Characteristic Curve Of Pumping Equipment Is Compulsory And Pumping Unit Is To Be Approved From The Concerned Sub Divisional Office Before Procuring. 3 Fabrication, Providing, Fitting And Lowering B Class Column Pipe Conforming To Is: 1239 Of Length 10 Rft Into The 200 / 250 / 300 Mm Casing Dia. Production Well Upto The Desired Depth ; The Job Includes Providing And Welding Of Flanges Conforming Tois: 6392, Table-17 And Pn 16 To These Pipes And Welding Of Flanges In Two Layers To Make The Flanged Joint Strong And Leak Proof. The Pipe Of 10 Ft Length Is To Be Weld On Both Sides With Flanges Using Welding Rod Of Reputed Make. The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts Bolts And R.I Gasket In The Flanged Joints Of Column Pipes. The Job Further Includes Cutting Of 2 No. Rectangular Cable Slots In Each Flange.The Dia Of Pipe Is 65 Mm. 4 Providing / Supplying And Fitting Of G.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class Cof65mm Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) . The Flanges Shall Be Double Welded Both From Inside And Outside Of The Pipe Using Standard Electrode Of Reputed Make. The Rising Main Is To Be Laid Over The Anchoring Blocks As Per Site Requirement.Flanges ( As Per Is 6392 / 1997 Table:17 ) Thickness Shall Conform To Is 6392 Part 1St Table-17. The Flange Welding Shall Be Carried Out In Double Layers Using Reputed Make Electrodes To Form Strong Welding Joint.Welding Electrodedc Arc Welding Using Welding Electrode Having Diameter Not Less Than 4Mm.Nuts And Boltsnuts And Bolts ( Conforming To Is:1363 Part 1St ) Rubber Insertion Gasketsrubber Insertion Gaskets ( Conforming To Is: 638 / 79 ) To Be Used Between Flanged Joints. 5 Providing And Fitting Ofdn 65 Mm Pn 1.6 / 16Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) . The Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions.It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work.The Job Includes Providing And Fitting Of 02 Nos. M.S Flanges Perfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fitted With Rising Main Of The Pumping Unit At Appropriate Spots As Per Site Requirement. The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job. A ) Size 65 Mm 6 Civil Works Required For Erection Of Gantry, Construction Of D.G Set Block 10X6 7 Earth Work In Excavation By Manual Means In Trenches For Foundation, Drains, Pipes, Cables ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Reaming Of Bottom Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed. All Kinds Of Soil01 Meter From Cutting Edge 8 Filling Available Excavated Earth In Trenches, Plinth, Sides Of Foundation Etc.In Layers Not Exceeding 20 Cm In Depth , Consolidating Each Deposited Layer By Reaming And Watering , Lead Upto 50 M Ad Lift Upto 1.5M. 9 Providing And Laying Of Soling Stone Including Manual Compaction 10 Centering And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For: Foundation, Footings, Bases For Columns 11 A. Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering . All Work Upto Plinth Level With 1: 2: 4 Mix ( 1 Cement , 2 Coarse Sand , 4 Graded Stone Aggregate 20Mm Nominal Size ) 12 Providing And Laying In Position 12 Mm Thick Cement Plaster Of Mix1:4 ( 1 Cement : 4 Fine Sand ) 13 Electrical Works 14 P / I / T / C Of Lt 3-Phase, 4 –Wire, Prodigy Meter Of Capacity 40-200 Ampere, 415 V, 50 Hz, Preferably Secure Make With All Accessories And Fittings , Cabling Required As Per Site Requirement .Note:- The Job Includes Complete Charging Of Subsation Which Includes Getting Clearnace From Pdd And Sealing Of Meter Etc. 15 Providing And Fitting Of 16 Mm Square Single Core Pvc Insulated Copper Cable For Interconnecting Various Electrical Gadets As Per Is 694: 2010 Along With Thimbling As Per Requirement. 16 P / I Of Earthing Station Forelectric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards. Safe Earthing Electrode Size:80 Mm Dia , Length :2000 Mmback Fill Compound :30 Kg 17 Providing, Installation, Testing And Commissioning Of Out Doorarea Lighting 120 Watt Led To Be Fiited On The Pump House Wall ( Externally ) Having Following Specs:Input: 90-240 V 50 Hzpower Factor: >0.9Colour Temperature: 4K - 6.5Kbeam Angle: 120° - 170°Lumens: >12000Operating Temperature: -20°C To 60°Cthe Led Is Pressure Die Cast Aluminum Housing With Power Coated Finish And Having Ingress Protection Up To Ip-68.The Led Is To Be Properly Fitted Outside On The Pump House. The Job Shall Include P / F Of 2-Corewire And 32 A Mcb As Switch For The Light. 18 Providing Of Transformer Oil Confirming To Is 335 ( Preferred Make : Power Oil / Indial Oil Servo / Hpcl ) 19 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Tubular Inverter Battery With Trolley And Cover. The Job Shall Include P / F Of Three No. Of Of Lighting Points With 9W Led Lamps Fiited In Holders In 1.5 Mm Square Copper Wire And On-Off Switches . The Job Shall Include P / F Of 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along With Other Accessories Like Ss-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 20 Miscellaneous Items 21 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: -Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide.Make: - Safe Volt / Jyotithe Rubber Mats Shall Be Accepted With Manufacturers Test Certificate 22 Fabricationof6’ X 6’ Angle Iron Bed By Way Of Providingand Fitting Of Structural Steel In Built Up Sections , Trusses And Framed Work, Including Cutting , Hoisting , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 23 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos Including Cutting , Fixingall Complete Including Painting Of The Play Sheet By One Coat Of Primer And Two Coats Of Enamel Paint 24 A ) Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cottonb ) The Job Also Includes Providing Of Pressure Cooker 5Ltr 02 No’S, Steel Patila ( Utensil ) 5Ltrs 02 No’S, Cooking Heater 01 No., Room Heater 01 No., Steel Buckets 10 Litre Capacity 01 No., Plastic Bucket 10 Litre Capacity With Mug 02 No’S Each, Steel Glasses 06 No’S, Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. All The Utensils Shall Be Of Prestige, Pigeon, Wonder Chef, United, Futura Make.The Job Also Includes Providing Of Thermo-Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. Of Samruddhi / Neel Kamal / Supreme / Anmol Make. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Godrej, Link Locks, Thapar Make. 25 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply. 26 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. Size: 4’×6’ Out Ms Angle Of 40X 40X 5Of 36 Rft And Ms Sheet Of 1 Mmthicktotal Weight Of50.16 Kgs 27 Tool Kit For Maintenance: -The Tool Kit For Maintenance Shall Comprise Of The Following And All The Items As Mentioned Below Shall Be Of Taparia Make:Providing Of Tool Kit Consists Of Following Items I. Double Ended Spanner ( Chrome Plated ) Of Size In Mm6 / 7, 8 / 9, 10 / 11, 12 / 13, 14 / 15, 16 / 17, 18 / 19, 20 / 22, 21 / 23, 24 / 26, 25 / 28, 24 / 27, 30 / 32Make – Taparia Each – 02 No.Ii. Double Ended Ring Spannerschrome Platedof Size Inmm 6 / 7, 8 / 9, 10 / 11, 12 / 13, 14 / 15, 16 / 17, 18 / 19, 20 / 22, 21 / 23, 24 / 26, 25 / 28, 24 / 27, 30 / 32Make – Taparia Each – 02 No.Iii. Allen Key Set Black Finish Of Size In Mm 1.5, 2, 2.5, 3, 4, 5, 6, 8, 10 Make – Tapariaeach – 2 No.Iv. Combination Pliersinsulated With Thick C.A Sleeve; Size In Mm 165, 210, 255Make – Tapariaeach – 02 No.V. Long Nose Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205Make – Tapariaeach – 02 No.Vi. Side Cutting Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205Make – Tapariaeach – 02 No.Vii. Insulated Screw Drivers ( Make – Taparia ) Blade Length In Mmblade Dia. In Mmtip Dimensions In Mm Quantity 50 3 1.6 X 0.4 ( 02No ) 75 3 1.6 X0.4 ( 02 No ) 100 3 3 X 0.4 ( 02 No ) 125 3.5 3.5 X 0.5 ( 0 No ) 2 150 3.5 3.5 X 0.5 ( 02 No ) 200 4 4 X 0.6 ( 02 No ) 300 5 5 X 0.8 ( 02 No ) Viii. Hammer With Handle Weight – 110 Mg , 340 Gm , 600 Gm –Each – 1No. Make Taparia. Ix. Heavy Duty Pipe Wrench Length In Mm- 200, 300, 600 Each – 01 No. Make Taparia.X. Electric Multimeter=1Noxi. Digital Multimeter – 1No. ( Fluke / Meco / Scemens / Mastech ) Xii. Digital Clamp Testercapable To Measure Up To 400A-1 No.Xiii. Hack Saw Framewith Hack Saw Blade – 01 No.Xiv. S-16Mxl, S- 16 H X L Socket Set ( 19 Sockets + 6 Accessories ) – 01 No. Make Tapariathe Job Includes P / F Of Chain And Allied Itemsto Theavailable C.P Block To Make It Functional. 28 Shifting, Erection Of 150 Mm Dia M.S.Pipes 2 No To Act As Vertical Posts And One No Ofchannel ( Ismc 300 ) To Act As Horizonatl Memeber.The Material Is To Be Shifted From Reshwini Store By Hiring A Private Mini Truck. The Job Includes All Tools And Tackes To Beused For Erection, Loading , Unloading And Carriages. The Job Shall Include Welding To Vertical And Horizontal Posts , By Use Of Ms Plate As Per Site Requirement . The Complete Structure Shall Be Painted With One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint. 29 Shifting, Installation, Testing And Commissioning Of 100 Amp Lt Control Panel, 25 Kva Voltage Stabilizer, 35Sq.Mm 3.5 Core And 100 Amp Mccb. ( Material Has Been Already Procured And Lying In The Sub-Divisonal Store ) . The Job Including All The Tools And Tackles To Be Used For Installation, Loading And Unloading And Carriage Charges From Sub-Stores To Wss. 30 Shifting, Installation, Lowering The 65 Mmdia G.I.Column Pipes. Fitting Of All Bends, Washout, Valves Etc To The Delivery Line And Also Layying And Fitting Of 6Sq.Mm Submersible Cable. ( Material Has Been Already Procured And Lying In The Sub-Divisonal Store ) . The Job Shall Include Providing / Fitting Of Nuts / Bolts, Rubber Washers Required For Fitment. The Job Including All The Tools And Tackles To Be Used For Installation, Loading And Unloading.The Job Also Included Carriage Charges From Sub-Stores To Wss And All Other Allied Works Related To The Job. 31 Shifting , Installation, Testing & Commissioning Of 25Kva – 3 Phase D.G. Set ( D.G Alreadyprocured And Lying In The Sub-Divisional Store ) .The Job Includes P / F Of New 150 Ah 12 Vbattery With Compatible Battery Charger, M.Oil Change Including P / F Of M-Oil , Replacement Of Filters And P / F Of Earthing To Dg Set As Per Norms And Site Conditions.The D.G Set Is To Be Connected To The Main Control Panel . The Job Also Includes Providing And Fitting Of Flexible Canvas Sleeve / Conduit For Carrying Conductor. The Job Including All The Tools And Tackles To Be Used For Installation, Loading And Unloading And Crane Hire And Carriage Charges From Sub-Stores To Wss.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
17.
Health and Family Welfare #10095342 AOC
Repairs And Renovation At Chc, Madugula In Anakapalli District.-Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , etc., complete for Brick Masonry Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , ..etc., complete for Reinforced cement concrete Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including all labour charges , ..etc., complete for Flooring Dismantling doors , windows and clear storey windows, Ventilators etc., ( wood or steel ) shutters including Chowkhats , architraves,hold fasts and other attachments etc., and stacking them within 100m lead including labour charge etc., ..complete for finished item of work For Not exceeding 3 sqm in area : Conveyance of un-useful excavated earth to a distance of 5 KM for disposal including hire charges of T & P, labour charges etc., ..complete for finished item of work. Earth work excavation for foundations (Manual Means) of buildings, septic tank, sump, compound wall in ordinary soils and depositing on bank with an initial lead of 10m and depth up to 3m including all operational,incidental, labour charges such as shoring, sheeting, planking, strutting etc., ..complete for finished item of work excluding dewatering charges etc., as per SS 20 B (APSS 308) Plain Cement Concrete (1:5:10) (cement: fine aggregate: Coarse aggregate) for foundations and under flooring bed using coarse aggregate 40mm size hard , machine crushed granite from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc. to site including all charges for machine mixing and hire charges of concrete mixer, laying concrete in foundations and under flooring bed, ramming in 15 cm layers finishing top surface to the required level curing etc.,.. complete for finished item of work. (APSS No. 402) For First Floor Vibrated Plain Cement Concrete (1:3:6) nominal mix using 40mm size machine crushed hard granite metal and 20mm graded machine crushed hard granite metal (coarse aggregate) in (2:1) ratio from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate (sand), coarse aggregate, water etc. to site, all charges for mixing and hire charges of concrete mixer, centering charges, laying concrete in position, vibrating, curing, centering charges, ..etc.,for finished item of work for footings and basement .For First Floor Providing Plinth protection with a bed of 100mm thick PCC(1:5:10) using 40mm size HB Granite metal and on top of PCC, 20mm thick granolithic concrete flooring with CC(1:1:2) prop.using 6mm to 12mm size graded hard granite machine crushed metal laid monolithically already laid, in alternate panels of size not exceeding 1.5 x 1.5 Mts. using 5mm thick glass strips and between the pannels and finishing the top surface to required smoothness and slopes including grooves, thread lining as directed by the Engineer - in - charge including cost and conveyance of all materials to site including seigniorage charges, sales & other taxes on all materials and operational & incidental and labour charges like mixing of cement concrete, laying, curing, lift charges etc.,..complete including cost of CC bed for finished item of work. (APSS No.701 & 710) For First Floor Supply and placing of the Design Mix Concrete M 25 grade corresponding to IS 456 with cement content of 380 kgs per 1 cum of concrete using weigh batcher / mixer with 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site, centering using steel scaffolding pipes , jack props , wallers , foot plates , brackets , steel centering plates etc., including all operational, incidental and labour charges such as weigh batching, machine mixing, lifting of concrete manually, laying concrete, vibrating, curing etc., ..complete but excluding cost of steel and its fabrication charges for finished item of work (APSS No. 402) For Plinth Beam Masonry work in CM(1:6) prop (Cement : Sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, fly ash cement / lime solid blocks, water etc., to site, labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., complete for finished item of work. (APSS No. 501 & 504). Plain Cement Concrete M 20 nominal mix using 20mm size graded machine crushed hard granite metal (coarse aggregate - as per IS 383 - 1970 and IS 2386 Part 1 to Part 8) from approved quarry using concrete Mixer 10 / 7 cft (0.2 / 0.8 cum) capacity including cost and conveyance of all materials like cement, fine aggregate(sand), coarse aggregate, water etc. to site including all charges centering, labour charges such as weigh batching, machine mixing, hire charges of concrete mixer, centering charges, laying concrete in position, curing etc., & lift charges , ..for steps for finished item of work. (APSS No. 402) For First Floor Plastering 12mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., ..complete for finished item of work (SS 901,903 & 904). For Comound wall Plastering 12mm thick single coat in CM(1:5) using screened sand including cost and conveyance of all materials like cement, sand, water etc., to site and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, curing as directed by Engineer-in-charge etc., ..complete for finished item of work (SS 901,903 & 904). For First Floor Supplying and fixing single side prelam solid panel PVC door frame (Choukhat): Providing and fixing factory made Pac single side Prelam door frame of the size 50x47 mm with a wall thickness of 5mm, made out of extruded 5mm rigid Pac single side prelam sheet, meter cut at two corners and joined with 2 Nos. of 150mm long brackets of 15 x 15mm MS Square tube. The two vertical door profiles are to be reinforced with 19 x 19mm MS. square tube of 19 guage. The door frame shall be fixed to the wall using 65/100mm long MS. Screws through the frame by using Pac fasteners. a minimum of 4 Nos. of screws to be provided for each vertical member and minimum 2nos. for horizontal member etc. complete as per manufacture specification and direction of Engineer-incharge including conveyance of all materials, labour charges for fixing, ..complete for finished item of work. Providing and fixing 30mm thick Brand factory made moulded PVC door shutter- wood free consisting of frame made out of MS. tubes 19 gauge thickness and size of 25mmX25mm for styles, top and bottom rails. MS. Frame shall hav e a coat of steel primers. The inner panel shall consist of 25mm thick high density EPS conforming to IS 4671-1984 bounded with 2mm thick termite proof, water proof and fire resistant moulded Pac sheet with 2,4,6 raised panel design in different plain and / or pre-lam colours after routing to the moulded design on one side and 2mm plain and / or pre-lam Pac sheet on other side of the EPS. The edge of panel to be sealed with lipping of 10mm wide PVC sheet bottom (made by sticking 2 rigid foam sheet of 5mm thickness using Pac solvent cement) and stiles sides 25mm(5mmX5) thick and 30mm width Pac sheet fitted along MS tube for lock provision for lock height 5mm thick Pac sheet of size 150mmX100mm fixed with upper and lower face of inner side of EPS panel etc., complete as per direction of Engineer – in-Charge, manufacture specification and drawing including supplying and fixing ISI marked Aluminium fixtures 3 Nos. butt hinges (IS:205) of 150mm long, 1 No. aldrop (IS:2681) 250 mm long, 1 No. tower bolt (IS:204) of 150 mm x 10mm dia, 2 Nos. 125mm long handles (IS:208),1 No. Rubber / Nylon door stop bushes including labour charges for fixing the shutter to frame etc., including ..complete for finished item of work for door of size 800mm x 2100mm Providing SPECIALISED ACRYLIC CEMENTITIOUS ELASTOMERIC WATERPROOF COATING TREATMENT Complies with ASTM C 297 : Providing and Application of two coats of Acrylic cementitious elastomeric waterproof coating with- Roofcoat or equavalent like high elastomeric acrylic polymer modified cementiitious waterproof system. complete for finished item of work and as directed by the Engineer- in - charge including cost and conveyance of all materials , labour charges , etc., complete for finished item of work. Providing Mild steel (MS) steel bars (Fe 250 grade as per IS 432) of different diameters including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying etc., complete for finished item of work.( APSS No.126) For Second Floor Flooring with non-skid red or white full body Ceramic floor tiles of size 300 mm x 300 mm and thickness between 7-8 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sand over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., ..complete for finished item of work. (APSS No.701 & 707) For First Floor Flooring with soluble salt porcelain vitrified tiles screen printed and polished of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders and design as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope as directed by the Engineer- in-charge etc.,..complete for finished item of work. (APSS No.701 & 707) For First Floor Providing skirting to internal walls to 10 cm height with Soluble salt porcelain vitrified tiles screen printed and polished of 8 to 10mm thick of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,..complete for finished item of work.(APSS No.701 &707) Providing dadooing with glazed red or white full body ceramic wall tiles of size 300 x 450 mm / 320 mm x 400 mm and thickness 6 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs with borders as approved by Engineer-in-Charge flushed to wall surface set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., ..complete for finished item of work. Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVCprofile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mmsize for fixing frame to finished wall and necessary stainless steel screwsetc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage ofwater etc. After fixing frame the gap between frame and adjacent finishedwall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge inclusive of cost of Single / double glass panes, wire mesh and silicon sealent . Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Two track two panels sliding window made of (small series) frame 52 x 44 mm &sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick double shutters with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides, fixing 1mm thick mat finish laminated sheet to full width and height of the flush shutter both sidesincluding cost and conveyance to site of teak wood frame, flush shutter, laminate sheet including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Alumimium fixtures of 6 Nos. butt hinges (IS:205) 150mm long, 1 No. aldrop (IS:2681) 300mm long, 2 Nos. tower bolts (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 2 Nos. door stoppers and 2 Nos. Rubber / Nylon door stop bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc., including complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1500mm x 2600mm) Supply and fixing of doors as per approved drawings with medium teak wood frame of section 100mm x 65 mm with split type fan light of 500mm at the top fixed with 4mm thick pin headed glass using 12mm x 12mm Teak Wood beading and 2 Nos. of 10mm MS Square bars and ISI marked flush door shutter of 30mm thick single shutter with bond wood solid block board type core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides fixing 1mm thick mat finish laminated sheet to full width and height of the flush shutter both sides including cost and conveyance to site of teak wood frame, flush shutter, laminate sheet including supply and fixing 6 Nos. MS Z hold fasts of size 300 mm x 40 mm x 5mm including cost of ISI marked Aluminium fixtures of 3 Nos. butt hinges (IS:205) 150mm long , 1 No. aldrop (IS:2681) 300mm long, 1 No. tower bolt (IS:204) of 200 mm x 10 mm dia at top, 2 Nos. 150mm long handles (IS:208), 1 No. door stopper and 1 No. Rubber / Nylon door stop bushes including fixing the fixtures to door with required number of screws, bolt and nuts including labour charges for fixing the frame in position, fixing the shutter to the frame, fixing glass in fan light portion etc, including ..complete for finished item of work as per APSS 1001 & 1002 (The vertical frame of door shall be embedded in flooring for a depth of not less than 10 mm) (1000mm x 2600mm) Supply and fixing doors as per drawings with medium teak wood frame of section 100mm x 65mm and ISI marked flush door shutter of 30mm thick single shutter with bond wood solid block board type Core having cross bands and face veneers, hot pressed bonded with water proof phenol formaldehyde synthetic resin factory made conforming to IS 2202-1991 (Part-I) both sides commercial ply with internal lipping on all sides including cost and conveyance to site of medium teak wood door frame, flush shutter, including suply and fixing 6 Nos. MS Z hold fasts of size 300mm x 40mm x 5mm including ISI marked Aluminium fixtures 3 Nos. butt hinges (IS:205) of 150mm long, 1 No. aldrop (IS:2681) 250 mm long, 1 No. tower bolt (IS:204) of 150 mm x 10mm dia, 2 Nos. 125mm long handles (IS:208),1 No. Rubber / Nylon door stop bushes including PVC door cladding 1.50mm thick to the flush doors shutters pasted with Fevicol complete as per direction of Engineer –in – charge, manufacturers specification and drawing to full height of the shutter inside including labour charges for fixing the frame in position, fixing the shutter to the frame etc., including ..complete for finished item of work as per APSS 1001 & 1002. (The vertical frame of door shall be embedded in flooring for deth of not less than 10mm) (800mm x 2100mm) Supplying and fixing of MS doors, grill to windows / in open court yards using MS angles, flat, square bars including cost and conveyance of all materials, cutting, bending, welding, all operational charges, labour charges, etc., complete for finished item of work. ALMIRAH SS1 Internal Size of Almirah: 1850 (H) X 900 (W) X 450 (D) mm, 2 Leg Size of Almirah: 150 (H) X 120 (W) X 450 (D) mm, 3 Rack with 5 Compartments. 4 Distance between each shelf will be 360 mm. 5 These 4 shelves should be hanging arrangement (adjustable). 6 One shelf should have internal door and lock7 Standard lock and 2 sets of keys. 8 The thickness of the Almirah sheet shall be 18 SWG. 9 The body of the Almirah shall be manufactured from cold rolled MS sheet (C. R. Sheet) with Antirust treatment and shall be finished with powder coating The quality of used M.S sheet for making Almirah shall be free from any pitting and corrosion etc. 10 H/D Rubber bushes shall be provided to the bottom of legs of Almirah.Certificates : ISO 9001 and BIS/Notified CE Supplying and fixing of Pre-painted Galvalume Trapezoidal Profile Roofing sheets with 0.50mm thickness, Coating: Alu-Zinc coating AZ150 GSM. Tensile Strength: 550 MPA. Paint coating: Regular Modified Polyester painting. Painting Thickness (Top): 18 to 20 Microns, (Bottom): 5 to 7 Microns. Sheet Width: 1.020, Length: Maximum 12 Meters with Regular Range Colours fixed with G.I ‘J’ bolts & nuts 8 mm dia with bitumen & G.I limpet washers filled with white lead & including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (up to a pitch of 600) etc., complete, excluding the cost of purlins, rafters, trusses including cost and conveyance of all materials , labour charges , etc., complete for finished item of work in all floors. Supplying and fixing of MS doors, grill to windows / in open court yards using MS angles, flat, square bars including cost and conveyance of all materials, cutting, bending, welding, all operational charges, labour charges, etc., complete for finished item of work. White washing two coats with white cement to ceiling to give an even shade after thouroughly brushing the surface to remove all dirt and remains of loose powdered materials including cost of all materials , labour charges and incidental such as scaffolding , lift charges etc., ..complete for finished item of work in all floors. Supply & application of one coat water based cement primer of interior grade I and two coats of acrylic emulsion paint having VOC (Volatile Organic Compound) content less than 50 grams/litre for internal walls including cost and conveyance of all materials to site, incidental, operational and all labour charges etc.,..complete for finished item of work in all floors. For First Floor Supply & application of one coat water based cement primer of exterior grade II and two coats of acrylic exterior emulsion paint having VOC (Volatile Organic Compound) content less than 50 grams/litre for exterior walls including cost and conveyance of all materials to site, incidental, operational and all labour charges etc.,..complete for finished item of work in all floors. Painting to new wood work and flush shutters with lappam finish , over a primary coat and painting two coats of synthetic enamel paint Grade-I VOC (Volatile Organic Compound) content less than 50 grams/litre of approved shade including cost and conveyance of all materials to site cost of primer coat and all labour charges etc. complete including applying sand paper on lappam coats for neat finish ..complete in all floors (APSS No.1200, 1207 & 1211). For First Floor Construction of Granular sub-base by providing HBG material confirming to Grading - III of MORT & H Table 400-2 including cost and conveyance of all material to work site and spreading in uniform layers with motor grader or by approved means, on prepared surface mixing by mix place method with Rotavator/ approved means, at OMC and compacting with vibratory roller to achieve the desired density etc., complete for finished item of work as per MoRT& H specification 401 (4th revision) and as directed by the Engineer- in - charge including cost and conveyance of all materials , labour charges , ..etc., complete for finished item of work (Payment will be made based on levels for finished item of work Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M 30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork ( laying and fixing of 125 mictron thick polythene film including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 MORD including cost and conveyance of all materials , labour charges , ..etc., complete for finished item of work. Supplying and fixing of 4 (101.6mm) multi floor trap with jali - UPVC/SWR pipe fittings as per site requirements with standard practice for all floors including cost and conveyance of all materials to site, labour charges , ..etc., complete for finished item of work. Supplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 31.75mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , ..for finished item of work Supplying and fixing European Water Closet of 1st quality conforming to IS:2556-Part-2-1973 of white glazed with S trap,supplying and fixing best Indian make plastic seat and lid for European water closets with rubber or plastic Buffers as per IS 2548-1996 and 10 litres capacity single flush PVC low level cistern with internal components and fixed using required size of nails and screws, angle stop cock 12.70mm dia. first quality Indian make heavy duty, 12mm PVC connections with brass union nuts CP coated including cost and conveyance of all materials to site, ..etc., complete for finished item of work for all floors. Supplying and fixing of stainless steel sink of size 508.00mm x 457.2mm x 203.20mm, 1mm thick of Indian make fixed on cantilever brackets including supply and fixing 31.75mm C.P. waste coupling, 31.75 mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality ncluding chiselling brick masonry wall and making good & restoring to original surfaces , ..complete for finished item of work in all floors. Supplying and fixing NP soap dish heavy type of approved make ISI quality with NP screws etc., complete including cost and conveyance of all materials, labour charges for fixing , ..for finished item of work in all floors Supplying and fixing TV shape mirror with plastic frame of size 609.6mm x 457.2mm , plywood back with NP screws 1st quality including cost and conveyance of all materials, labour charges , ..for finished item of work in all floors. Supplying and fixing of 25.4mm dia , 609.6mm long aluminium anodized towel rods with brackets and aluminium screws including cost and conveyance of all materials, labour charges , ..for finished item of work. Supplying and fixing NP bib taps of size 12.70mm dia of Indian make heavy duty (short body) as approved by the Engineer-In-Charge including cost and conveyance of all materials, labour charges , ..complete for finished item of work in all floors. Supplying and fixing NP bib taps of size 12.70mm dia of Indian make heavy duty (long body) as approved by the Engineer-In-Charge including cost and conveyance of all materials, labour charges , ..complete for finished item of work in all floors. Supplying and fixing of SWR PVC pipes (Prince/Sudhakar/Kisan/Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, ..complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) For 75mm dia Supplying and fixing of SWR PVC pipes (Prince/Sudhakar/Kisan/Supreme or any ISI brand) 4 Kg/Sq.cm. and fixing all special such as plain bends, off sets, door bends, single junctions, double junctions as per site requirement, fixing with PVC clamps if necessary with required number of Bombay nails including cost and conveyance of all materials to site, labour charges, ..complete for finished item of work at all floor levels. (APSS No. 1302 1319 & 1326) For 110mm dia Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2 to 2) for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, ..complete for finished item of work at all floor levels. For 15.90mm OD pipe Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2 to 2) for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, ..complete for finished item of work at all floor levels. For 22.20mm OD pipe Supply and fixing of Ashirvad/ Ajay/ Astral Flowguard or equivalent CPVC Pipes and Fittings SDR 11 to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2 to 2) for hot and cold water (IS 15778:2007) including cost and conveyance of all materials to site, labour charges for fixing, ..complete for finished item of work at all floor levels. For 28.60mm OD pipe Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , ..complete for finished item of work. For 15mm Nominal bore Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , ..complete for finished item of work. For 20mm Nominal bore Supplying and fixing Gunmetal Gate ( GM peet ) valve as per IS-778 Class - I , Indian make heavy type including cost and conveyance of all materials , labour charges , ..complete for finished item of work. For 25mm Nominal bore Supply and Fixing of 25mm outer dia (1.60 to 1.80)mm thicknes medium grade with IS:9537 part 3 FRLS rigid Surface P.V.C. pipe (ISI marked) on wall with all required PVC Junction Boxes confirms to IS : 3419 and all accessories fixing on chromium plated metallic base saddles for run of mains including all labour charges etc., complete. including all labour charges etc., complete. Makes: Precision/Universal& Marudhar/VIP / GoldMedal / Million plast / GM / Sudhakar /Polycab/Anchor/ Polyline/ Orbit/AKG/Beljin/Vasavi/DEC Supply and Fixing of of 16A/6A, 2 in one, modular type power socket outlet with 16A switch (ISI marked) modular type and 2 No of 6A modular type sockets with 6A modular type (ISI marked) switch control with front cover plate on existing modular switch box including all labour charges, giving all connections etc., complete with following configurations1) 16A Socket - 2 No2) 16A Switch - 2 No3) 6A socket - 2 No. 4) 6A switch - 2 No Makes:Legrand(Myrius/Lyncus)/Schneider(Clipsal X/ Livia AB)/ Crabtree (Murano/Athena)/Lauritz Knudsen-englaze (Formerly L&T)/ GM-(Four-Five)/Goldmedal(GIFA)/Million (M-VEE)/Anchor (Roma PLUS)/Precision(Series7)/Honeywell(Blenzepro) Supply and run of 3 of 2.5 sq.mm (phase neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing MS conduit pipe for individual ligting circuits including labour charges etc., complete as required for switch boards.Makes: Finolex / RR kabel / Havells/Finecab/KEI/Polycab/Gloster/Goldmedal/GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi) Supply and 3 runs of 4.0 sq mm (phase neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in existing conduit pipe for run of mains including labour charges etc., complete as required including labour charges for 16A sockets.Makes: Finolex /RRkabel/Havells/Finecab/KEI/Polycab/Gloster/Goldmedal/GM/ FortuneArrt/Anchor/Million/ APAR(Anushakthi) Supply & run of 5 of 10.0 Sqmm (phases, neutral and earth) FRLS / FRLSH / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible copper cable in the existing conduict pipe for run of mains from Power panel board to TPN DBs with pin type lugs and connections etc., complete. [for PDBs] Makes: Finolex / RR kabel / Havells/Finecab/KEI/Polycab/Gloster/Goldmedal/GM/ Fortune Arrt/Anchor/Million/ APAR(Anushakthi) Supply and fixing of TPN 4 way distribution board with IP-43 protection and as per IS 8623; IS 13032; IEC 61439-3, (8+12 Module) with provision to accommodate the ELCB incomer and suitable for single pole outgoing MCBs in sheet steel enclosure with 63A, 10 KA breaking capacity c curve 4 pole MCB as incomer and 12 No of 6 to 32A, single pole, 10 KA breaking capacity c curve MCBs as outgoings including making connections etc., complete on wall. (LIGHTING DB). Makes: Legrand (Ekinox 3) / Schneider-A9/Hager -Novello+/ Seimens/Havells STADx/ Lauritz Knudsen (Formerly L&T)-Newrange/Indo Asian-Opti Pro/ HPL (Techno)/ Anchor (Uno Plus) Supply and Fixing of single phase DB in sheet steel enclosure as per IS 8623; IS 13032; IEC 61439-3 with metalic plug and socket with 1 No. 20/32A,10KA c curve SPMCB control including labour charges and giving connections etc., complete concealed in wall. Makes for DBs: Legrand(Ekinox 3) / Schneider-Acti9/Hager-Novello+/Seimens/L&T-Newrange and Makes for MCBs: Legrand-DX3 / Schneider-Acti9/Hager-h3/ Siemens-5SX4/ L&T-AU . Supply and Fixing of 20-24W, not less than 1100mm length LED batten light with extruded alluminium / CRCA housing and polycarbonate cover, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV, THD<15%, with high power LEDs having efficacy of ≥ 120 lumens / watt with inbuilt and replacable driver with earth connection brought outside and frosted cover CCT: 3000K - 5700K, minimum CRI>70 etc., complete including fixing on wall / Ceiling with PVC/TW round blocks with all accessories including giving connections and all labour charges etc., complete with 5 years warranty.Make: a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton / Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal/Eveready// Rhino/Panasonicb) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/ Everlight Supply and Transportation of 48 (1200mm) Sweep star rated Ceiling Fan , with double ball bearings, air delivery more than 200 cubic meter/min but without Regulator.Makes: Crompton (HS Plus/HS) / Havells (ES PLUS/SS390ES) /Orient Energy Star/ Halonix(Zephyr)/Polycab(Synergy 50 ISI) / G.M. (Air Wave Premium)/Bajaj-Edge/Arcline (Glacier) Supply, Transportation, Installation, Testing and Commissioning of the following Inverter model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidigation 1.5 TR 5 star capable of delivering 18000 BTU/hr and above with operating on refrigerant R-32/ R-410A, COP not less than 4.5. Makes: / Blue Star / Daikin / Hitachi/Carrier / LG/Lloyd (prevailing models in the market). Supply, Fabrication of 1set MS bracket suitable for fixing out door unit of split AC unit. Supply and fixing of copper pipes of different dia and thickness for distribution, half drawn, tempered, seamless, phosphorous deoxidized, non arsenic and decreased confirming to BS 2871-1971 Part-1 (Table-X) and the chemical compositions shall be as per BS 6017 of 1981 table-2 with Lloyd Test Certification, including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work. Make: IBP Conex / Maxflow. For 12mm O.D x 0.7 mm Supply and fixing of copper pipes of different dia and thickness for distribution, half drawn, tempered, seamless, phosphorous deoxidized, non arsenic and decreased confirming to BS 2871-1971 Part-1 (Table-X) and the chemical compositions shall be as per BS 6017 of 1981 table-2 with Lloyd Test Certification, including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work. Make: IBP Conex / Maxflow. For 15mm O.D x0.9mm Supply and fixing of copper pipes of different dia and thickness for distribution, half drawn, tempered, seamless, phosphorous deoxidized, non arsenic and decreased confirming to BS 2871-1971 Part-1 (Table-X) and the chemical compositions shall be as per BS 6017 of 1981 table-2 with Lloyd Test Certification, including cost and conveyance of pipes, cost of necessary specials made of copper and suitable for a steam working pressure of 17 bar and should confirm to BS 864 with specially made for brazed socket type connections, including taxes, transportation charges including laying and jointing, testing, commissioning and all other labour charges etc. complete for finished item of work. Make: IBP Conex / Maxflow. For 22mm O.D x0.9mm Supply and fixing of Isolation Valves with necessary brass end fittings designed for a working pressure of 300 psi / 27 inc. Hg. Vacuum, Non Ferrous, Non Lubricated with 90 degrees turn, Hand lever operated of standard make of valves including cost and conveyance of all materials, taxes, transportation charges, fixing charges and testing charges and all labour charges etc. complete for finished item of work. Make: IBP Conex / Maxflow For 15 mm Valves (1/2) Supply and Fixing of Oxygen Flow meters with Humidifier Bottles.Makes: Aktiv Technologies// Atlas Capco/ Draeger Medical/ / Airox Technologies / Aastha Medical technologies/ GMP Technical Solutions / Medicare gas pipe line/Mediline Engineers Supply and fixing Gas Outlet Points for Oxygen / Air / Vaccum with S Brackets, self ceiling bross valves / din type outlets with nut and cap and it shuld be 100% self sealing type , so that at the time of removal of probe, it shuld stop gas flow automatically, out let shuld be single hand insertion, non inter changeable for specific gas, it should accept only correct medical gas adapter. with down tube of the specific gas should be brazed with brass bracket of the outlet, there after brass bracket should be fixed in wall with the help of the steel screw, with self sealing valve which should be screwed with the front portion of brass bracket and there after it should be covered by plastic cover duly colour coded as per specific gas, design of outlet should be such that it can be installed vertically on wall, horizontally on ICCU panel and also vertical to fit in pendants including cost and conveyance of all materials, errection charges, commissioning charges and all other labour charges etc, complete for finished item of work. Makes: Aktiv Technologies// Atlas Capco/ Draeger Medical/ / Airox Technologies / Aastha Medical technologies/ GMP Technical Solutions / Medicare gas pipe line/Mediline Engineers
Contract Date: Ref. Documents Contract Value : 25.87 Lakh
Government Departments No of Bidders 1
Andhra Pradesh View Result →
19.
Defence #9835139 AOC
Tender For Completion Of Incomplete Work For Provn Of Otm Accommodation (Ph-I Of Two Phs) At Panagarh Mil Stn Under Ge (P) Panagarh.; 1 Sch A Part -I (Building Works)Note:- This Sch is notpre-priced by MES and the pre-priced rate indicatedas Rs 0.00 under Col 5 signifies this fact only. 2 Completion of incomplete Building for signal unit with all fitting and fixtures etc. Complete all as specified and as shown on complete drawings. 3 Completion of incompleteBuilding for office accn/ Adm block with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 4 Completion of incomplete Building for JCO Mess and single living JCO accn with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 5 Completion of incomplete Buildingfor single living ORs accn / Dinning and cook house with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 6 Completion of incomplete Building for Storage Accn (Armouries)& Guard House alongwith hardstanding with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 7 Completion of incomplete Building for Store Room (General Authorisation) with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 8 Completion of incomplete ramp with all fitting and fixtures etc. Complete all as specified and as shown on drawings 9 Completion of incomplete Building for sentry post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 10 Completion of incomplete Building for Ironing Room with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 11 Completion of incomplete Building for Meter & Switch House with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 12 Completion of incomplete Pump House/ UG water tank with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 13 Completion of incomplete RCC OHT Tankwith 18mtr staging with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 14 Completion of incomplete Incinerator with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 15 Completion of incompleteFlag mast with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 16 Completion of incomplete Alarm post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 17 Completion of incompleteFire point with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 18 Completion of incomplete Refuse bin with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 19 Completion of incompleteDhobi ghat with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 20 Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATIONas listed in Schedule ‘A’ Part-II on Serial Page No. __ 21 Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III on Serial Page No. __ 22 Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. __ 23 Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V on Serial Page No. __ 24 Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI on Serial Page No. __ 25 Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII on Serial Page No. ___ 26 Lumpsum price worked out by the tenderer/ bidder for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VIII on Serial Page No. ___ 27 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX on Serial Page No. ___ 28 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLYas listed in Schedule ‘A’ Part-X on Serial Page No. ___ 29 Lumpsum price worked out by the tenderer/ bidder for LIGHTENING PROTECTIONas listed in Schedule ‘A’ Part-XI on Serial Page No. ___ 30 Lumpsum price worked out by the tenderer/ bidder for RAIN WATER HARVESTING / RECHARGE PIT as listed in Schedule ‘A’ Part-XII on Serial Page No. ___ 31 Schedule ‘A’ Part-XIII (MISCELLANEOUS ITEMS)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 signifies this fact only. 32 M & L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e10 %Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed .Note:Break down details of this Items is shown in Annexure ‘B’ in Schedule ‘A’ Notes. 33 (INTERNALELECTRIFICATION)Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box screws complete including PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point / call bell point controlled by one, one way switch complete all as specified and as directed. 34 All as per Ser Item No 13.02 here-in-above but for one ceiling/ exhaust fan point controlled by one switch complete all as specified and directed. 35 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one 5/6 Amps socket outlet points controlled by one, one way switch on independent board complete all as specified and as directed. 36 All as per item No. 13.04 above but one 5/6amps socket outlet point on the same board with other switches complete all as specified and as directed. 37 All as per item No. 13.02 above but for one Point wiring controlled by two nos two switch complete all as specified and as directed. 38 Material and labour for point wiring with 4sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 4 sqmm green colour as earth continuty conductor connected to common earth dolly for one15/16 Amps socket outlet points controlled by one, one way switch modular type on independent board complete all as specified and as directed. 39 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed stove enameled steel conduit of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point controlled by one, one way flame proof rotary type switch complete all as specified and as directed. 40 Supply and fixing switch flame proof rotary type with terminal box in LM6, 16 amps single pole 230 volts complete all as specified and as directed. 41 M & L for modular metal flush box 12 Module complete all as specified and directed. 42 M & L for modular white cover plate with frame, 12 module complete all as specifed and directed. 43 S & F for LED lamp 7 watt (retrofit) complete all as specifed and directed. 44 S & F LED type conical shape wall metal body with 1 no 7 Watt retrofit LED Lamp minimum lumen 700, complete all as specifed and directed. 45 S & F LED type table lamp / bed side light ( 3000k) Metal body 2 Watt minimum 50 lumen complete all as specifed and directed. 46 S & F telephone Socket (RJ-11) modular type complete all as specifed and directed. 47 S & F TV Socket modular type complete all as specifed and directed. 48 Supplying and fixing ceiling fan five star rated withBrush Less direct current (BLDC) 1200 mm sweep (without remote ) , 28 W complete withblades,down rod and accessories,230v,Min delivery 210 CFM with service value 6.00 BEE complete all as specified and as directed. 49 All as per Ser Item No 13.17 here-in-above but for 1400mm sweep, Minium air delivery 245 CFM with service value 6.00 BEE, five star rating with brushless direct current motor (BLDC) complete all as specified and directed. 50 Supplying and fixing exhaust fan made of sturdy Engineering plastic complete with lovers shutters, AC single phase, 230 V, 50 HZ , 1200 RPM, Copper winding, 250mm Sweep complete all as specified and directed. 51 Supplying and fixing exhaust fan noiseless square type metal body case , 450mm sweep heavy duty single phase (1400 RPM) ISI marked with blades flush mounting withlouvers, AC single phase 230/240 volts, 50 Hz including necessary fixing accessories and make good of surfaces complete all as specified and as directed. 52 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 6 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 53 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 8 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 54 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 4 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 55 Supplying and fixing MCCB 125 Amps, capacity 25kA, 4 pole, 415 volts (Adjustable thermal type & fixed magnetic setting) complete all as specified and as directed. 56 Supplying and fixing sheet metal enclouser for DBS Single pole and neutral 6 way double door with 200 Amps rated bus bar 240 Volt complete all as specified and as directed. 57 Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm diawith all fittings and conduit accessories concealed type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note:-(i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 58 Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm dia with all fittings and conduit accessories concealed type including one runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 59 Material and labour for sub main wiring with four runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less tha 25 mm dia with all fittings and conduit accessories concealed type including two runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) Four runs of cable with two runs earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 60 Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including complete all as specified and directed. {NOTE:- (i) Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item..} 61 (ROAD/PATH)M & L 225 mm thick (compacted thickness)wet mix macadam( WMM), with curshed stone aggregate and stone dust (as per design mix)of specifiedgrading, spread using mechanical paver as specified, watered, rolled & consolidated as specified to required gradient and camber complate all as specified & directed. 62 M&L for laying polythene paper black 150 micron with laps complate all as specified & directed. (Area for polythene paper without considering lap shall be measured and paid) 63 M&L and laying 150 mm thick (compacted thickness) wet mix macadam (WMM) with crushed stone aggragate of specified grading,spread using mechanical paver as specified, watered, rolled and consolidated as per required greadeant and camber complate all as specified & directed. 64 M&L for 100 m thick dry lean concrete (DLC) over a prepared subgrade with coarse and fine aggregate conforming to IS : 383, Size of aggregate not exc 40 mm (Grading and other parameters as per table 600 - 1 of MORTH, IRC SPR : 49 Specification) complate all as specified & directed. 65 M&L for cleaning and preparing the road surface and making good for road marking applying reflective thermoplastic white road marking paint (HOT APPLICATION) comforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass, beads, titanium dioxide, calcium carbonate, interfiller thermoplastic required for glass beads per square meter by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and as directed.Make of Thermoplastic Road marking paint/Retro-Reflective paint - M/s Asian Apcomark, M/s STP or M/s Shalimar Paints Ltd or M/s Berger Paints Ltd, M/s Jhonson & Nicholson Paints Ltd or M/s Jotun India Pvt Ltd. 66 (SEWAGE DISPOSAL)M&Lfor constrution of RCC Septic tankcoventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users Complete all as shown on drawing and as directed. 67 M&L for constrution Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.5 M effective depth Complete all as shown on drawing and as directed. 68 (EXTERNAL WATER SUPPLY) Design, supply, install, testing and commissioning Iron removal pressure feed type filtration plant 10000 GPH to with stand pressure 10 Kg/Sq cm with catalytic and filter media (as required size and grade / mesh to obtain potable water recommended parameters as per WHO) including MS frontal pipe (duly welded), Cocks, valves, (inlet outlet, back wash, rinse, bypass complete as per manufacturers instruction). Provision of main hole Hand hole strainer including air vent system, coagulant feeder with accessories, oxidation chamber with media, (MnO2) with all accessories suitable capacity with all fitting fixture, pressure gauges, RCC/PCC foundation as per OEM recommendation. Drainage system and connected to rising and delivery system including painting and writing complete. The technical details of Oxidation chamber and Multigrade filter are as given below:- 69 A) Oxidation Chamber- (i)Feed Flow - 40 M³/Hr. (ii) Operating pressure - 3.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm. (iv) MOC of vessel - MS. (v) Frontal Pipeline Size - 150/100mm. (vi) Media type - Manganese-di-oxide. (vii) Thickness in mm (shell and dish-ends) - 6 mm. (viii)Media Quantity - 600 Kg. (B) Multigrade Filter- (i) Flow rate - 40 M³/Hr. (ii) Operating pressure - 3.5-5.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm². (iv) Continuous duty cycle - 48 Hrs. (v) Backwash - 20 Min. (vi) Rinsing - 10 Min. (C) Filtering Media Details- (i) Media Type - Mixed sand. (ii)Depth of sand - 2800 Kg. (iii) Depth of Gravels support - 2000 Kg. (iv) Guaranteed life of filtering media - One year.(D) Vessels Details- (i) Type Cylindrical - Vertical. (ii)Dimension in mm (DIA X HOS) - 1600 X 2300 mm. (iii) Free board for back wash - 50%. (iv)Materials - MS. (v) Thickness in mm (shell and dish-ends) - 8-10mm. {Note:-- Rate deemed to be included with the followings:-(a)Raw water and treated water tested report of all parameter from National Test House Salt Lake. (b)Training to DEL Staff with required material and maintaining log book and other register as directed. (c) Electronic flow meter-01 including necessary wiring complete. (d)Butter fly and gate valves as required.(e) 2 Nos air compressor of capacity 210 CFM with 3 Phase Motor, Starter, air pipe connection including electrical connection complete. 70 Supply, install, lowering, testing & commissioning of submersible pump set 8 stage, suitable forminimum head 40 Mtr with 635 lpm dischage with electric driven motor of capacity 15 hp, 415 V AC, TP with operational efficeiency performance and durability wide voltage range 350-440 Volts, super finished water lubricated bush bearing, with less speed drop motors with reflon bearing and sand guard complete all as specified and directed by Engr-in-charge. 71 Trail drilling of bore of size 250 mm dia upto 120 mtr depthby direct rotary/ DTHmechanical system for injection wellin any kind of soil strata including hard stone/boulders and submitting the strata detail both graphically recorded as well as strata results including testing of yield , complete all as specified and as directed. 72 Reaming of bore well from 250 mm dia to 525 mm dia hole in three steps from 250 mm to 350 mm, 350 mm to 450 mm and 450 mm to 525 mm dia bore siutable for lowering ERW Mild steel casing pipes and gravel packing for the required length (i.e 50 mtr depth) below the ground level , complete all as specified and as directed. 73 All as per item no 13.41 here-in-before but exceeding 50 mtr and upto 170 mtr depth, complete all as specified and as directed. 74 Supply, assembling, lowering and fixing in position 250 mm nominal (10) bore ERW MS housing pipe, ISI marked,of 8 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth upto 40 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding , complete all as specified and as directed. 75 Supply, assembling, lowering and fixing in position 200 mm nominal (8) bore ERW MS housing pipe, ISI marked,of minimum 8.0 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth exceeding 40 mtr and upto 120 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding, complete all as specified and as directed. 76 Supply, assembling, lowering and fixing in position low carbon galvanized (LCG) steel strainer pipe 200 mm nominalbore of wall thickness 7.00 mm cagetype wire wound screen ‘V’ shaped profile in suitable length having slots of size 1.6 mm width including necessary end coupling,electric Arc welding as required and including special sockets for connecting to MS pipe, complete all as specified and as directed. 77 Supply and fixing mild steel reducer suitable for (250 x 200 mm ) bore casing pipe, 10 mm thick, fitted to casing pipe as per IS 2800 by means ofelectric Arc welding ,complete all as specified and as directed. 78 M&L for carrying out electro logging test upto complete drilling depth of tube well for fixing water strata and submitting of Report including its interpretation by a qualified Hydrologist/ground water expert , complete all as specified and as directed. 79 S&Fmild steel bail plug assembly suitable for 200 mm bore casing pipe internal threaded with strong iron hook, screwed and welded to casing pipe as per IS 2800 , complete all as specified and as directed. 80 Supply, filling and packing washed pea gravels of size 2 mm to 4.6 mm all around casing pipe and slotted pipe, complete all as specified andas directed 81 S&F mild steel housing clamps 1200 mm long 100 mm wide , made out of 20 mm thick MS plate made to shape for 250 mm bore casing pipe with necessary bolts, nuts and washers at ground level, complete all as specified and as directed. 82 Developing of tube well by means of air compressor, for number of hours, until sand free clear potable water is obtained including testing by using diesel engine driven turbine pump to get maximum yield and discharge including supply of yield test result , complete all as specified and as directed. (Note : The rates of DHPP is inclusive in the quoted rate) 83 S & F well cap made out of 5 mm thick MS Plate with provn of suitable holes for passing two runs of flat 3 core PVC insulated sumersible cable motor and one run of SWR, 100 MM dia column pipe and suitable for fixing 250 mm nominal bore ERW heavy duty MS of 8.0 Mm Wall thickness casing pipe complete all as specified andas directed. 84 S&F pressuregauge with isolation cock suitable for a working pressure of 7 Kg/cm² (Liquid based High Intensity), complete all as specified and as directed. 85 Supply and laying flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work , complete all as specified and as directed. 86 S&F round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed ,complete all as per directed. 87 Supply , lowering and fixing MS column pipe 100 mm bore, medium grade, confirming to IS, 3 meter long pipe both end flanged, threading, welding and drilling of holes, cutting of ducts of size 10 mm x 20 mm 2 No. in each flange for fixing submersible cable, including rubber gasket of suitable size, nuts, bolts, washer etc including painted internally and externally with two coat of non corrosive non toxic bituminous paint including making all type of connections as required, complete all as specified and as directed. 88 Supply , install, testing and commissioning of cubical housing cabinet type weather proof powder coated LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proofof CPRI approved,openablefrom both front and rear side made of2 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- 89 (i) Aluminium Bus bar 160 Amps -25 KA breaking capacity(ii) Incoming MCCB, 4 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacityQty 1 No(iii) Outgoing MCCB, 3 pole, 32 Amps, 415 Volt AC, 10KA rupturing capacityQty 4 Nos(03 For submersible pump and 01 standby)(iv) Outgoing MCB 4 Pole 32 Amps, 10 KA, 240 Volts - 01 Nos(v) Star delta motor starter suitable for 15 HP motor pump - 03 Nos(vi) LED indicating lamps - 03 Nos(vii) Digital Volt meter (Size - 96 x 96mm) 0-500 Volts with selector switch - 01 No(viii) Digital Ammeter (Size96x96mm) With selector switch including CT ( 100/5Amp) with all connection- 01 No(xiv) Matering and accessories complete all as directed by Engr-in-Charge. 90 Supply, installation, commissioning and testing of 200mmsluice valveof cast iron body flangedconforming to IS-14816, PN-1.6 Non rising type spindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 91 Supply, installation, commissioning and testing of 150mmsluice valveof cast iron body flanged conforming to IS-14816, PN-1.6 Non rising typespindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 92 Material and labour for Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 93 Material and labour for Construction of brick masonry valve pit of internal dimension 60 cm x 60 cm x 60 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 94 Supply, install, testing & commissioning of Centrifugal pump suitable for minimum, Discharge 635 LPM at 30 Mtr head with cast iron casing, bronze impeller, SS Shaft, electric driven motor of 10 HP, 415 V, TP suitable for under ground sump and install complete including PCC foundation as per manufacture instruction complete all as specified and directed. 95 Supply, install, connecting, testing & commissioning of high pressure single head adjustable chemical dozing system of the folowing specification : (a) Adjustable high pressure 100 PSIG Power input 230 V, 50 HZ, Max flow rate 02 US GPD to 40 US GPD with mandatory assecceries like lead tubing connecting ferrules, check valves, 170 ltr FRP solutin preparetion tank with lid, port hole, inlet/outlet/drain connection, level guage ete and fitted with 900 RPM motor PVC agitator combined with 100 ltr dosing tank lid port hole inlet/outlet/drain connection, level guage etc either fitted with 900 RPM moter and PVC agitator complete all as speficified and directed.Make : Any make of E-in-C approved or ISI Marked of any make as approved by Accepting Officer. 96 Supply and laying DI Pipe 200mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 97 Supply and laying DI Pipe 150mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 98 M&L DI Fittings bends (any type radius and angle) tapers any type, (straigth, bend, increasing, decreasing or double socket etc) Tee pieces single branch Y junctions double branch, cross (all sockets or socket and spigout ) collars, caps and plugs upto 300 mm bore complete all as specified and directored. 99 (EXTERNAL ELECTRIC SUPPLY)suply , installation and commissioning of compact secondary substation (CSS) 315KVA comprising to following parameters:-(a) Housing to made with conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to high voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lighrening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h) Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside fo the CSS.(l) Necessary HT and LT cable / earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 100 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs adn PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet enclosure with automatic sagety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch. 101 (vii)Shunt trip coil- 230 V, AC(viii) Safety interlock locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, space heater with thermostat, fuse adn ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle(xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 315 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 25.% on HT side all technical specification comprising to IS 11171 update version part with all necessary satndard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 315 KVA (ii)Primary Voltage - 11 KV AC(iii) Secondary Voltage - 433 Volts . 102 (iv)Neutral earthing should be solidly earth system (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs). q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 103 Suply , installation and commissioning of Compact Secondary Substation (CSS) 250 KVA comprising to following parameters :-(a) Housing to bemade with Conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to High voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lightening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h)Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside of the CSS.(l) Necessary HT and LT cable / Earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 104 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs and PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch.(vii)Shunt trip coil- 230 V, AC(viii) Safety Interlock Locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, Space heater with Thermostat, Fuse and ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle. 105 (xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 250 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 2.5% on HT side all technical specification comprising to IS 11171 update version part with all necessary standard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 250 KVA (ii)Primary Voltage - 11 KV AC 106 (iii) Secondary Voltage - 433 Volts (iv)Neutral earthing should be solidly earth system. (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance.(p)LT Panel for 250 KVA Transformer made with 2 mm CRCA sheet with necessary angle iron frame and vermin proof font side openable double door with necessary locing arrangement opening for bus bar / cable entry opening for natural air ventilation / cooling necesary Ammeter, Voltmeter, Selector switch, CTs , suitable size bus bar, paints and primer with Air Circuit Breaker (ACB) as incomer 630A, 50 KA, 415 V , AC, 50 Hz, 4 Pole with neccesary setting and microprocessor control draw out type bus bars, as outgoing MCCB 200 Amps, 35 KA - 02 Nos, MCCB 160 Amps, 35 KA - 02 Nos & 32 A MCB 4 Pole - 04 Nos. (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs).(q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 107 Supply and fixing LED street light fittings on ploes capacity 45 Watts, high pressure die cast aluminum housing IP 66 rating front cover made of toughened clear glass, suitable for pole mounting wih bracket arm 40mm dia, Gl light grade pipe upto 1.4 m long, bend to required shape, clamp 40mmx6mm or required length including nuts & bolts fixed on steel poles complete all as specified.Model No : ENDURASUNDOWNSL45WLED765PASYBOTG of make : Havells or equivalent make as per Appendix D. 108 Supply & Fixing junction box with 3 Phase terminals and size of box 130mm x 180mm x 77mm or nearest higher size made of polycarbonate with IP 66/67 degree of protection, dust proof, water tight,shock proof, fire retardant,with internally embedded gasket fitted with heat treated bakelite for terminals block and PVC Glands for cable entry complete all as directed 109 M&L Three core 1.5sqmm(nominal area)service wire PVC insulated copper conductor FRLS, multi stranded, unsheathed 1100 volts grade IS-694 marked andfrom junction box to street light fitting through steel pole withPVC conduit & necessary clamps, bolts & nut etc required for fixing complete all as specified and directed. 110 Supply , install, testing and commissioning of cubical housing cabinet type conforming toCPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowings :-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -200 Amps , cable entry (incomming and outgoing ) form bottom with cable gland Incomming : 125 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No (Incoming from CSS)Outgoing -(a) MCCB 4 pole 100 Amps 25 kA - 02 Nos (for signal unit and 1 standby)(b) MCCB 4 pole 16 Amps 25 kA - 2 Nos (For OFFR Living ,meter or switch house and and 01 No for street lights)(c)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor(d) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) LED indicating lamps -03 Nos 111 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -400 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 250 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 200 Amps 35 kA - 01 Nos (Adm buidling)(b) MCCB TPN 16 Amprs 25 KA-02 Nos (Guard house and standby)(c) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(d) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No(e) LED indicating lamps -03 Nos. 112 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approvedLT panel board Outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -600 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 315 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 125 Amps 35 kA - 03 Nos(02 Nos for OR Accomodation and 01 Nos standby)(b) MCCB 4 pole 63 Amps 25 kA - 01 Nos(JCO Accomodation and JCO Club) (c) MCCB 4 Pole 25 Amprs 25 KA - 01 Nos (Drying and ironing room)(d) MCCB TPN 16 Amprs 25 KA - 02 Nos (Street lights and one standby)(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos (g) LED indicating lamps -03 Nos (h)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor 113 Supply, install, testing and commissioning of Automatic Power Factor Correction (APFC) panel board of aggregate capacity 15 KVAR suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, outdoor type, cubicle, floor mounted, free standing dust and vermin proof, air ventilation made out of 3 mm thick CRCA sheet duly powder coated, Manufactured shall be CPRI norms and as approved by GE, factory made.Panel board shall have front and rear opening with hinged type doors and rubber gasket, handles, industrial type locking arrangement, cable alleys, switch gear compartment, bottom cable, entry holes for incoming and outgoing cables, earthing terminals, danger notice plate, Aluminum bus bar duly covered with heat shrink sleeves of colour coded duly fixed on DMC / SMC insulators housed in a separate bus bar chamber including control wiring with PVC insulated, flexible, multistranded copper conductor cables of adequate size and of adequate length for connecting of capacitors, contactors etc duly ferruled crimped with suitable lugs / thimbles and including connecting of incoming and outgoing cables. Panel board shall be mounted on and including MS angle iron frame of suitable size duly painted and PCC1:2:4 type B1 for foundation / Platform to suit the site requirement complete all as specifiedand directed and comprising of following:-(i) APFC relay microprocessor based digital display type of 9 stages suitable for operation of PF upto unity – 01 No. 114 (ii) MCCB 320 Amps, 4 pole, 50KA, 415V, 50HZ – 01 No for incoming.(iii) MCCB 80 Amps, 4 pole, 25KA, 415V – 03 No’s for capacitor outgoing.(iv)MCCB 40 Amps, 4 pole, 25KA, 415V – 01 No for capacitor outgoing.(v)MCCB 16 Amps, 4 pole, 25KA, 415V – 05 Nos for capacitor outgoing(vi) MCB SP 0.5 to 5 AMPS, ‘C’ Curve, 240V-09 Nos as per circuit control.(vii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -05 Nos.(viii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -02 Nos.(ix) Capacitor Bank 1 KVAR, 3 phase, 440V MPP type including suitable rating contractor -01 Nos. 115 (x) LED indication lamps RYB – 01set.(xi) Auto / manual selector switch -01No.(xii) Push button and indication lamp for each capacitor bank -01 set.(xii) Digital voltameter with selector switch -01set.(xiv) Digital ammeter with selector switch & CT’s -01.(xv) Aluminium bus bar TPN 480 Amps rating -01 set.Note: The contractor should be factory inspection and drawings approval by the GE / Engineer-in-Charge before procurement after commissioning of APFC panel the power factor (PF) to achieve 0.95 to 0.99 mandatory at any load condition automatically. 116 Supply and fix solar street light smart integrated solar system all in one with MPPT (Maximum Power Point Tracking) charge controller ,Tilable LED Panel,Adjustable AIO mounting angle ,mono crystalline solar panel ,PIR motion sensor, and 6m tubular pole with 30 wattLED light at a rate 100 lm/w, 60wp, 75 AH (Lithium ferrous phosphate battery luminaries must have a life of greater than 50,000 hours and have IP 66 rating, the modules are to bedesigned to with stand corrosive atmosphere and heavy wind loads. the modules are to be certified for standers IEC 61215, IEC 61730 (Safely class I & II) complete all as specified and directed. 117 Supply and fix LED post top lantern decorative typeo fttings for 360 degreee indirect light on pillars of capacity 40 watts high pressure die cast aluminium housing IP 65 rating, suitable fr mounting 40 dia GIlight grade pipe upto 0.5 m long or required length including nuts and bolts and fixed complete all as specified and directed.Model No : RUBYPT40WLED757PSYMTOPC OF MAKE : Havels or equivalentmake as per Appendix D 118 M&L fpr boring holes horizontally under road without damaging the surface of road (minimum 1 mtr below the road surface/ footpath with the help of GI tubing not exceeding 100mm dia bore for passing of UG cable complete all as specified and directed. 119 (REFGIGERATION & WATER COOLER) Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 308 - 315 ltrs capacity, conforming to IS 15750 (2006) for frost free, with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 120 Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 192 - 210 ltrs capacity, conforming to IS 1476 for direct cool with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 121 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 320 ltrs, BEE 5 star rating complete all as specified and directed. 122 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 400 ltrs, BEE 5 star rating complete all as specified and directed. 123 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacityof 40 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 124 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 120 ltr and nominal cooling capacityof 60 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 125 S & F Voltage stablizer of capacity 2 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 126 S & F Voltage stablizer of capacity 1 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 127 (DG SET) M&L Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected tousing galvanised iron strip 32×6mm as earthing lead earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated by Engr-in-charge including testing on completion. 128 Supply and installation testing and commissioning silent Diesel Enginegenerating set 415 volts 40 KVA3 phase 0.8 power factor, 50 Hz, 1500RPM self exicited self regulated brushlessAC generator installed including AMF panel,suitable for ambient condition at Panagarh and confirming to condition under ISO 3046, IS:10001/ 10002,BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :- (A) Alternator:- Synchrounous alternator rated at 40 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system.The alternator shall be brushless, single bearing, self excited/ self regulated with an AVR. The alternator will be suitable for climate and shall generally confirm to IS: 4722 :2001. The salient features of the alternators are :- (a) +-1% voltage regulation (max) in static conditions.(b) IP:23 protections with class H insulation.(c) Permanent lubricating bearing. 129 (B) Diesel Engine:- Adquate capacity of diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500RPM, as per relevant IS/BS complete with standard accessories. (C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent (to comply GRIHA and other agencies norms) canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimentional accuracy of holes within 0.1 mm.Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility (D) AMF panel : Automatic Mains Failure (AMF) panel made of CRCA sheet of 2 MM thick including necessary arrangement to install, testing and commissioning & connecting ot load cable to up ot changeover switch, suitable capacity of 4 pole MCCB complete all as per OEM recommendation.(E) Civil Works :- All civil works including PCC platform and related foundations incl for panel and equipments incl making goodof disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommendedby the manufacturer. 130 (F) AMF Panel Specification shall be as per manufacture instruction.Note :-The contractor shall be arrange for artificial load resistive for testingof DG set at site and the cost is deemed to be included in the quoted ratesMAKES :- Make of engine : CUMMINS/KIRLOSKARGREEN/ASHOK LEYLAND/ GREAVES COTTON.Make of alternator : KIRLOSKAR GREEN / ALSTOM / CROPTON GREAVES /SIEMENS 131 Supply, erecting,testing aand commissioning of solar water heating system with heat exchanger for cold & warm regions respectively with solar evacuated tube collection conforming to IS : 12933 (Part - i ) with amdt No 1 and IS : 12933 (Part 2) /2003 suitable for inlet water with chlorine and fluorine content up ot 100 ppm and supply hot water at the outlet of 200 litters capacity with elctrical back up meeting specifications as under and comprising of followings :-Supply and fixing rotational moulded polyethylene water storage tank (Cylindrical Vertical with closed lockable top with lid and locking arrangement) hoisted and fixed in position all as specified in SSR Part -I of capacity 200 Litters complete for storage of cold water feeding to solar water heater, including staging made out of MS Angle iron 50x50x6 mm all as specified and directed at site by Engineer-in-Charge.Material :- Soalr water heating System : Comprising of solar Evacuated tube Collector, Collectors stand assembly.Staniless steel insulated hot water Storage tank with heat exchange and various other components . Solar evacuated tube collector component shall have :Evacuated tube collector component shall have : solar Evacuated tube collector cover plate made of toughened glass.Sheet for absorber made of copperAbsorber made of copper sheet and copper tube.the minimum thickness of Aluminium shall be as under:- (a) Channel section for sides 1.6mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm sheet for entire body 1.0 m AbsorberAbsorber shall consist of riser, header and sheet for absorer. The diameter of header shall be 25.4 +/- 0.5 mm and thickness 0.71 mm. The Diameter of riser shall be 12.7 +/- 0.5 mm and thickness 0.56 and made of copper only. 132 S & F Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed. 133 Rain water Harvesting /Recharge PitS & F 150 MM perforated UPVC pipe with 20% Perforation complete all as specified and directed. 134 S & F 150mm bore PVC (SWR) vent cowl complete all as specified and directed. 135 M&L for hand packed gravel (Stone chips 12.50mm) for filling in bore holes and inside of recharge pit complete all as specified and directed. 136 Boring for 350 Mm Dia bore to a depth of 40 mtr in soil and getting out and disposal of spoil to a distance of 50 mtr using DMC method ( Direct mud Circulation) complete all as specified and directed. 137 GRIHA RATING FOR FOLLOWING BUILDING:-Minimum 3 star GRIHA rating shall be obtained for the following buildings which includes pre-certification and final ratings from approved aggency(a) OFFICER/ ADMIN BLOCK (b)SINGLE living JCOs ACCN(c) SINGLE living HAV/OR ACCN (T/S)Note :- 01The GBA (Green Building adviser) ofr obtaining GRIHA certification shall be approved by Accepting Officer.02. The GBA shall be responsible for all necessary actions for obtaining final GRIHA rating as per following guide lines:- (a) Pre-Cretification :-1. Submission of GRIHA per certification documents to certification agency as applicable immediately after the issue of Job/Work order.2. Analysis and suggest improvement/correction in the MEP/Other relevant drawings/documents and draft tender of the subject work for GRIHA star Rating (Min Three Star).3. Preparation, Submission & uploading all the documents in accordance with the GRIHA requirment, documentation shall be supported by drawings, test result quipment catalogues & calculations.4. Selection of equipment & material.5. To facilitate the planning team for selection of appropriate energy efficient & eco -friendly technologies, equipment & materials for the building e.g lighting system ,white goods, water treatment technologies, renewable energy, nontoxic paints, rapidlly renewable materials, recycled materials, ecofriendly materials etc.6. preparation of vendors & suppliers list for inclusion in the tender & working out specification of equiptment & materialto suit the GRIHA requirement. 138 7. Develop templates for GRIHA calculations to achieve certain points, this include materials related criteria, construction of waste management at site, energy calculation etc.8. conduct solar path analysis for each to achieve the best design ( shading device, Orientation etc.)9. Conduct solar path analysis for each fenestration to achieve the best design ( shading device, orientation etc)10 Perform day light analysis to ensure optimun condition achieved as per the guidelines provided by ECBC 2007.11. Perform day light analysis for window -wall ration, glass peropertiies (SHGC) & Providing recommendations to meet the compliance of ECBC 2007.12. Perform hourly calculation to show that thermal comfort condition as well as non-condition area are cachieved.13. Perform energy simulation to predict the energy performance of energy system in the bldg is less than the benchmarked energy perfomance as prescribed by GRIHA.14. Submit of ECBC compliance document to show that compliance fo mandatory requirment of ECBC are meet.15.Submission of draft specification to comply with relevant criteria of GRIHA for inclusion in tender documents.16. Liasoning and coordinating with GRIHA team for registration of project, uploading relevant document. Responding ot queries, observations, modification and corrections given by GRIHA team within specified time framed and reporting client with lates update.17. completion of all documentation requirement and formatlities before conclusion of main bldg. Contract and obtaining pre-certification with 3 or above star rating. 139 Final Rating:-Acquiring of Final Post GRIHA (minimum 3 star rating) certification approval from GRIHA including changes in drawings/ design during execution of work.Note:-The consultancy fees is inclusive of the following:-1. Pre-certification Registration Fees2. Certification registration Fees3. Site visit of GRIHA Official4. Site visit of GRIHA Official5. Third party EvaluatorPayment Schedule :-(i) 10% after pre-certification(ii) 50% at finalisation of specification(iii) 40% after obtaining GRIHA certification 140 Providing and fixing white vitreous china floor mounted water closet of size 360X640X685 mm of approved shape including providing and fixing vitreous china cistern with duel flush fitting, of flushing capacity 3 litre/6litre (adjustable to 4litre/8litre, including seat cover, and cistern fitting nuts, boltsand gasket etc complete all as specified and directed.Model No: SLS-WHT--6851P of make Jaquar of equivlent make/model as specified in Appendix D. 141 Providing and fixing white vitreous china wash basin for under counter mounting, specially fabricated brackets, painted whit, brass tap, 32 mm C.P. Wast, 15mm C.P. Brass self closing tap, connection pipe & rubber adopter for waste connection, complete including cutting and making food the walls, wherever requird complete all as specified and directed.Cat No : CNS_WHT_705 for wash basin ofmake Jaquar& Cat No PRS-031 for 15mm C.P brass tapof make Jaquar or equivlent make/model as specified in Appendix D. 142 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. Size 485 X 310 X 710 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction of Engineer-in-Charge.Cat No : URS-WHT-13255 of make of equivlent make/model as per Appendix D 143 Providing and Fixing of P.V.C waste Flexible pipe 40mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 144 Providing and Fixing of P.V.C waste Flexible pipe 15mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 145 Providing and fixing C.P. Brass angle valve 15mm dia for basin mixer and gyser pointsconforming to IS : 8931 complete all as specified and directedCat No FLR-CHR-5053N of make of equivlent make / model as per Appendix D. 146 Providing & fixing Liquid soap container of standard shape with bracket of the same material with snap fitting of approvedquality and colourcomplete all as specified and directedCat No : CAN-1135N of make of equivlent make / model as per Appendix D 147 Provinding & fixing Sink cock 15mm nominal bore of approved quality and colour complete all as specified and directedCat No : FLR-5347ND of make of equivlent make / model as per Appendix D 148 Provinding & fixingCP Brass Health faucet with 1.5M S.S Flexible Tube with wall hook including screw, Nut, bolts, cutting wall/floor and making good the same whatever required complete all as specified and directedCat No : ALD-CHR-583 of make of equivlent make / model as per Appendix D 149 Provinding & fixingCP Brass Bid cock Including wall fange, Connections, screws, nut, bolts, cutting wall/floor and makiing good the same whatever requiredcomplete all as specified and directedCat No : FLR 5037Nof make of equivlent make / model as per Appendix D 150 Provinding & fixing sink CP Wall mount double Robe Hookfixed to wooden cleats with C.P Brass screws, cutting wall/floor and making good the same whateverrequired complete all as specified and directedCat No : CAN-1161N of make of equivlent make / model as per Appendix D 151 Providing and fixing of straight type Macfit Single body push fit type WC pan connector with factory supplied srpring loaded seal guard of mcalpine, UK with integral single mould sealing fins made of flexible eva body, including bush/ adaptor for use with C.I pipe as supplied with the pan connecrtor complete all as specified and directed. Model : MAC 1 of make Macalpine of equivlent Model as approved by E-In-C or Accepting officer. 152 HOT WATER SUPPLYSupply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 15 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 153 Supply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 25 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 154 S&F CP Brass stop cock (concealed) of 100mm dia of standand design conforming to 15:8931 complete all as specified and directed. 155 Providing and fixing sound insulated PP piping system as per ON EN 1451 _ Part I-6 & EN 12056 part I-5 with 3 Layer pipe made of PP-C +PP-MV+PP-C in Blue Ral 5014 (Halogen and calcium free) colour, Push-fit type, food safe having high impact and stiffness, offering sound level of not more than 22dBA at a flow rate of 4 I/S and having pipe ring stiffness as per ISO/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560 with all necessary fillings in blue colour, filled with factory fitted lip ring of make : Polyplast or equivalent make as approved by GE suitable for PP110mm dia Pipes complete all as specified and directed. 156 All as per item No 14.24 here-in-after but for PP 75mm dia pipes 157 All as per item No 14.24 here-in-after but for PP 40/50mm outer dia meter pipe (For wash basin etc) 158 Providing and fixing floor trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connection, 110mm inlet& 110m outlet long hight complete all as specified and directed. 159 Providing and fixing 110 X 50mm UPVC Floor Drain / Plain Floor trap complete all as specified and directed. 160 Providing and fixing SS Grating Over Floor Trap& Floor Drain 127 X 127mm complete all as specified and directed. 161 M&L concrete bed to drain pipe including packing under and lacking against the side of pipe after they are laid and tested with PCC (1:4:8) type D-2, for 110mm dia complete all as specified and directed. 162 All as per srl item No 14.30 here-in-after but for PP 40/50mm outer dia meter pipes. 163 S&F clean out cap plug (FCO/COP) for cleaning of same materials (POLO KAL NG) for PP 110mm dia complete all as specified and directed. 164 S&F 3-layer PPR-polypropylene random copolymer conceled pipes SDR 7.6 (PN-16) UV stabilized and antimicro bial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting for 50mm outer dia laid in trinches complete all as specified and directed.
Contract Date: Mar 17, 2026 Contract Value : 59.85 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
West Bengal View Result →
21.
Petroleum and Natural Gas #9579982 Technical Bid
Supply Of Ball Plug And Needle Valves Ii Supply Of Ball Plug And Needle Valves Ii At Numaligarh Refinery Limited , 3 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Floating Ball, Api 608, -, Astm A216 Gr.Wcb, 150 Lbs, Ff, Ends As Per Asme B16.5, -, Bronze Ball, Bronze Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, -, , 2 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Floating Ball, Api 608, -, Astm A216 Gr.Wcb, 300 Lbs, Rf, Ends As Per Asme B16.5, -, Aisi 316 Ball, Aisi 316 Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, -, , 4 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Floating Ball, Api 608, -, Astm A216 Gr.Wcb, 300 Lbs, Rf, Ends As Per Asme B16.5, -, Aisi 316 Ball, Aisi 316 Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, -, , 2 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Floating Ball, Api 608, -, Astm A216 Gr.Wcb + Pwht + Sour Service, 150 Lbs, Rf, Ends As Per Asme B16.5, -, Aisi 316 Ball, Aisi 316 Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, -, , 3 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Floating Ball, Api 608, -, Astm A216 Gr.Wcb + Pwht + Sour Service, 150 Lbs, Rf, Ends As Per Asme B16.5, -, Aisi 316 Ball, Aisi 316 Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, -, , 6 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Floating Ball, Api 608, -, Astm A216 Gr.Wcb Epoxy Lined, 150 Lbs, Ff, Ends As Per Asme B16.5, -, Bronze Ball, Bronze Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Go, -, -, -, -, -, -, , 6 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Trunnion Ball, Api 6D + Asme B16.34, -, Astm A216 Gr.Wcb, 300 Lbs, Rf, Ends As Per Asme B16.5, -, Aisi 316 Ball, Aisi 316 Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Aisi 316, Seat Inserts: Rptfe, -, -, Go, -, -, -, -, -, -, , 8 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Trunnion Ball, Api 6D + Asme B16.34, -, Astm A216 Gr.Wcb, 300 Lbs, Rf, Ends As Per Asme B16.5, -, Aisi 316 Ball, Aisi 316 Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Aisi 316, Seat Inserts: Rptfe, -, -, Go, -, -, -, -, -, -, , 8 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Trunnion Ball, Api 6D + Asme B16.34, -, Astm A216 Gr.Wcb, 600 Lbs, Rf, Ends As Per Asme B16.5, -, Aisi 316 Ball, Aisi 316 Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Aisi 316, Seat Inserts: Rptfe, -, -, Go, -, -, -, -, -, -, , 12 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Trunnion Ball, Api 6D + Asme B16.34, -, Astm A216 Gr.Wcb + Pwht + Sour Service, 150 Lbs, Rf, Ends As Per Asme B16.5, -, Aisi 316 Ball, Aisi 316 Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Aisi 316, Seat Inserts: Rptfe, -, -, Go, -, -, -, -, -, -, , 8 In Ball Valve Flanged Ends, Reduced Bore, Long Pattern, Trunnion Ball, Api 6D + Asme B16.34, -, Astm A216 Gr.Wcb Epoxy Lined, 150 Lbs, Ff, Ends As Per Asme B16.5, -, Bronze Ball, Bronze Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Bronze, Seat Inserts: Rptfe, -, -, Go, -, -, -, -, -, -, , 6 In Ball Valve Flanged Ends, Full Bore, Long Pattern, Trunnion Ball, Api 6D + Asme B16.34, -, Astm A216 Gr.Wcb + Pwht + Sour Service, 300 Lbs, Rf, Ends As Per Asme B16.5, -, Aisi 316 Ball, Aisi 316 Stem, 2 Or 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Aisi 316, Seat Inserts: Rptfe, -, -, Go, -, -, -, -, -, -, , .75 In X S-Xs Ball Valve With 2 Nipples, Full Bore, Floating Ball, Api 608, -, Astm A105n, 800 Lbs, Sw Ends W/ 2 Pe Nipples, Ends As Per Mnf Std, Aisi 316 Ball, Aisi 316 Stem, 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, -, , 1 In X S-Xs Ball Valve With 2 Nipples, Full Bore, Floating Ball, Api 608, -, Astm A105n, 800 Lbs, Sw Ends W/ 2 Pe Nipples, Ends As Per Mnf Std, Aisi 316 Ball, Aisi 316 Stem, 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, -, , .75 In X 3.2Mm Ball Valve With 2 Nipples, Full Bore, Floating Ball, Api 608, -, Astm A105n, 800 Lbs, Sw Ends W/ 2 Pe Nipples, Ends As Per Mnf Std, Aisi 316 Ball, Aisi 316 Stem, 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, Nipple Thickness Shall Be Match With Is 1239 Part 1 - Heavy , 1 In X 4Mm Ball Valve With 2 Nipples, Full Bore, Floating Ball, Api 608, -, Astm A105n, 800 Lbs, Sw Ends W/ 2 Pe Nipples, Ends As Per Mnf Std, Aisi 316 Ball, Aisi 316 Stem, 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, Nipple Thickness Shall Be Match With Is 1239 Part 1 - Heavy , 1 In X 4Mm Ball Valve With 2 Nipples, Full Bore, Floating Ball, Api 608, -, Astm A105n, 800 Lbs, Sw End W/ 2 Nptm Nipples, Ends As Per Mnf Std, Aisi 316 Ball, Aisi 316 Stem, 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, Nipple Thickness Shall Be Match With Is 1239 Part 1 - Heavy , 1 In X S-40S Ball Valve With 2 Nipples, Full Bore, Floating Ball, Api 608, -, Astm A182 Gr.F304/304L, 800 Lbs, Sw Ends W/ 2 Pe Nipples, Ends As Per Mnf Std, Aisi 316 Ball, Aisi 316 Stem, 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, -, , .75 In X S-Xxs Ball Valve With 2 Pup-Pieces, Full Bore, Long Pattern, Floating Ball, Api 608, -, Astm A105n + Sour Service, 150 Lbs, Bw Ends W/ 2 Be Pup-Pieces, Ends As Per Asme B16.25, Aisi 316 Ball, Aisi 316 Stem, 3 Pcs Split Body Side Entry, Bolted Connection, -, -, -, -, -, Seat Rings: Rptfe, Seat Inserts: -, -, -, Lo, -, -, -, -, -, -, , .5 In X S-Xxs Needle Valve Bw Ends, Long Pattern, -, Api 602, -, Astm A105n + Sour Service, 150 Lbs, Bw Ends, Ends As Per Asme B16.25, Welded Bonnet, -, -, -, -, -, Api Trim No 9, -, Seats: -, Swivel Needle, -, Stem: Os & Y/Rsro, -, Ho, -, -, -, -, -, Caustic Service , .5 In X S-Xxs Needle Valve Bw Ends, Long Pattern, -, Api 602, -, Astm A105n + Sour Service, 300 Lbs, Bw Ends, Ends As Per Asme B16.25, Welded Bonnet, -, -, -, -, -, Api Trim No 9, -, Seats: -, Swivel Needle, -, Stem: Os & Y/Rsro, -, Ho, -, -, -, -, -, Caustic Service , .5 In X S-Xxs Needle Valve Bw Ends, Long Pattern, -, Api 602, -, Astm A105n, 150 Lbs, Bw Ends, Ends As Per Asme B16.25, Welded Bonnet, -, -, -, -, -, Api Trim No 12, -, Seats: -, Swivel Needle, -, Stem: Os & Y/Rsro, -, Ho, -, -, -, -, -, C.A. = 4.8 Mm, Corrosive Service , .5 In X S-Xxs Needle Valve Bw Ends, Long Pattern, -, Api 602, -, Astm A105n, 300 Lbs, Bw Ends, Ends As Per Asme B16.25, Welded Bonnet, -, -, -, -, -, Api Trim No 12, -, Seats: -, Swivel Needle, -, Stem: Os & Y/Rsro, -, Ho, -, -, -, -, -, C.A. = 4.8 Mm, Corrosive Service , .5 In Needle Valve Female Ends, -, Api 602, -, Astm A105n, 800 Lbs, Sw Ends, Ends As Per Asme B16.11, Welded Bonnet, -, -, -, -, -, Api Trim No 5, -, Seats: -, Swivel Needle, -, Stem: Os & Y/Rsro, -, Ho, -, -, -, -, -, -, , .5 In Needle Valve Female Ends, -, Api 602, -, Astm A105n, 800 Lbs, Sw Ends, Ends As Per Asme B16.11, Welded Bonnet, -, -, -, -, -, Api Trim No 5, -, Seats: -, Swivel Needle, -, Stem: Os & Y/Rsro, -, Ho, -, -, -, -, -, Inside Dia Shall Be Match With Is 1239 Part 1 - Heavy , 6 In Plug Valve Flanged Ends, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A216 Gr.Wcb + Pwht + Sour Service, 150 Lbs, Rf, Ends As Per Asme B16.5, -, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Go, -, -, -, -, -, Caustic Service , 2 In Plug Valve Flanged Ends, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A216 Gr.Wcb + Pwht + Sour Service, 150 Lbs, Rf, Ends As Per Asme B16.5, -, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Lo, -, -, -, -, -, Caustic Service , 3 In Plug Valve Flanged Ends, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A216 Gr.Wcb + Pwht + Sour Service, 150 Lbs, Rf, Ends As Per Asme B16.5, -, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Lo, -, -, -, -, -, Caustic Service , 2 In Plug Valve Flanged Ends, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A216 Gr.Wcb + Pwht + Sour Service, 300 Lbs, Rf, Ends As Per Asme B16.5, -, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Aisi 316 Plug, -, -, Lo, -, -, -, -, -, Corrosive Service , 2 In Plug Valve Flanged Ends, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A216 Gr.Wcb + Pwht + Sour Service, 300 Lbs, Rf, Ends As Per Asme B16.5, -, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Lo, -, -, -, -, -, Caustic Service , 3 In Plug Valve Flanged Ends, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A216 Gr.Wcb + Pwht + Sour Service, 300 Lbs, Rf, Ends As Per Asme B16.5, -, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Lo, -, -, -, -, -, Caustic Service , .5 In X S-Xxs Plug Valve With 2 Pup-Pieces, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A105n + Sour Service, 150 Lbs, Bw Ends W/ 2 Be Pup-Pieces, Ends As Per Asme B16.25, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Lo, -, -, -, -, -, Caustic Service , 1.5 In X S-160 Plug Valve With 2 Pup-Pieces, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A105n + Sour Service, 150 Lbs, Bw Ends W/ 2 Be Pup-Pieces, Ends As Per Asme B16.25, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Lo, -, -, -, -, -, Caustic Service , .75 In X S-Xxs Plug Valve With 2 Pup-Pieces, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A105n + Sour Service, 150 Lbs, Bw Ends W/ 2 Be Pup-Pieces, Ends As Per Asme B16.25, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Aisi 316 Plug, -, -, Lo, -, -, -, -, -, Corrosive Service , .5 In X S-Xxs Plug Valve With 2 Pup-Pieces, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A105n + Sour Service, 300 Lbs, Bw Ends W/ 2 Be Pup-Pieces, Ends As Per Asme B16.25, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Lo, -, -, -, -, -, Caustic Service , .75 In X S-Xxs Plug Valve With 2 Pup-Pieces, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A105n + Sour Service, 300 Lbs, Bw Ends W/ 2 Be Pup-Pieces, Ends As Per Asme B16.25, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Lo, -, -, -, -, -, Caustic Service , 1.5 In X S-160 Plug Valve With 2 Pup-Pieces, Regular Pattern, Tapered Plug,Non Lubricated, Api 599,-, Astm A105n + Sour Service, 300 Lbs, Bw Ends W/ 2 Be Pup-Pieces, Ends As Per Asme B16.25, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Uns N04400 Plug, -, -, Lo, -, -, -, -, -, Caustic Service , .5 In X S-80S Plug Valve With 2 Nipples, Regular Pattern, Tapered Plug,Non Lubricated, Api 599 Where Applicable,-, Astm A182 Gr.F304/304L, 800 Lbs, Sw Ends W/ 2 Pe Nipples, Ends As Per Mnf Std, Bolted Bonnet, -, -, -, -, -, Seats: Rptfe Sleeve, Aisi 316 Plug, -, -, Lo, -, -, -, -, -, - => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 14
22.
Defence #9578160 AOC
Tender For Provision Of Otm Accommodation (Phase -I) At Bagrakote Under Ge Sevoke; 1 BUILDINGS & STRUCTURE (Sch A PART-I) 2 Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE”as listed in Schedule ‘A’ Part-I.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 36,31,20,000.00 inserted by the MES in Schedule ‘A’ Part-I. 3 EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch A PART-II) 4 Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT”as listed in Schedule ‘A’ Part-II.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 52,49,260.89 inserted by the MES in Schedule ‘A’ Part-II. 5 INTERNAL WATER SUPPLY (Sch A PART-III) 6 Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-III.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 46,308.98inserted by the MES in Schedule ‘A’ Part-III. 7 INTERNAL ELECTRIFICATION (Sch A PART-IV) 8 Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-IV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 96,32,540.67 inserted by the MES in Schedule ‘A’ Part-IV. 9 ROAD, PATH & CULVERT (Sch A PART-V) 10 Lump sum price worked out by the Contractor for “ROAD, PATH & CULVERT)”as listed in Schedule ‘A’ Part-V.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 86,86,643.57 inserted by the MES in Schedule ‘A’ Part-V. 11 SEWAGE DISPOSAL (Sch A PART-VI) 12 Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL”as listed in Schedule ‘A’ Part-VI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 23,70,861.02inserted by the MES in Schedule ‘A’ Part-VI. 13 AREA DRAINAGE(Sch A Part-VII) 14 Lump sum price worked out by the Contractor for “(AREA DRAINAGE)”as listed in Schedule ‘A’ Part-VII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 64,06,702.01 inserted by the MES in Schedule ‘A’ Part-VII. 15 CHAIN LINK FENCING AND GATE (Sch A PART-VIII) 16 Lump sum price worked out by the Contractor for “(CHAIN LINK FENCING AND GATE )”as listed in Schedule ‘A’ Part-VIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 16,99,635.84 inserted by the MES in Schedule ‘A’ Part-VIII. 17 EXTERNAL WATER SUPPLY (Sch A PART-IX) 18 Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY”as listed in Schedule ‘A’ Part-IX.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,04,432.28inserted by the MES in Schedule ‘A’ Part-IX. 19 EXTERNAL ELECTRIFICATION (Sch A PART-X) 20 Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)”as listed in Schedule ‘A’ Part-X.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 66,58,717.06 inserted by the MES in Schedule ‘A’ Part-X. 21 FIRE FIGHTING & FIRE ALARM SYSTEM (Sch A PART-XI) 22 Lump sum price worked out by the Contractor for “FIRE FIGHTING & FIRE ALARM SYSTEM”as listed in Schedule ‘A’ Part-XI.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 32,30,010.00inserted by the MES in Schedule ‘A’ Part-XI. 23 HOT WATER SUPPLY (Sch A PART-XII) 24 Lump sum price worked out by the Contractor for “HOT WATER SUPPLY”as listed in Schedule ‘A’ Part-XII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 6,63,253.28 inserted by the MES in Schedule ‘A’ Part-XII. 25 LIGHTNING PROTECTION (Sch A PART-XIII) 26 Lump sum price worked out by the Contractor for “LIGHTNING PROTECTION”as listed in Schedule ‘A’ Part-XIII.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 29,821.10 inserted by the MES in Schedule ‘A’ Part-XIII. 27 COOLING APPLIANCES (Sch A PART-XIV) 28 Lump sum price worked out by the Contractor for “COOLING APPLIANCES”as listed in Schedule ‘A’ Part-XIV.Representing ** ___ % ______ percent *Above / Below the lump sum price ofRs. 4,24,714.16 inserted by the MES in Schedule ‘A’ Part-XIV. 29 DEMOLITION & DISMANTLING (Sch A PART-XV) 30 Lump sum price worked out by the Contractor for “DEMOLITION & DISMANTLING”as listed in Schedule ‘A’ Part-XV.Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 12,25,480.08 inserted by the MES in Schedule ‘A’ Part-XV. 31 MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch A Part-XVI) 32 INTERNAL WATER SUPPLYS&F ofGun-metal, globe or gate valve, 65 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 33 S&F ofGun-metal, globe or gate valves, 80 mm bore of pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 34 S&F 15 mmbore brass CP mixer for hot & cold water screwed down for iron / CPVC pipe and fixed (3-in-1) complete all as specified and directed. 35 S&F 15 mm bore fancy type, chromium plated basin inlet connection (angle valve), cast copper alloy, screwed down, high pressure, screwed both ends for iron / CPVC pipe for unions and fixed complete all as specified and directed. 36 S&F two way bib cock with wall flange chromium plated with crutch or butterfly handle screwed down screwed for iron / CPVC pipe 15 mm borecomplete all as specified and directed. 37 S&F health faucet with stainless steeltube and wall hook suitable for 15 mm dia pipe with 1 meter long flexible tube including making connections and fixed in pipe etccomplete all as specified and directed. 38 INTERNAL ELECTRIFICATIONS & F modular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed.(AC& GYSER POINT) 39 S & F MCB 25A, 230 V, 50 Hz, 2P MCB (C curve) conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed. 40 All as per Srl Item No. 16.08 here-in-above but for 16A, 230 V, 50 Hz, 2P MCB (C curve) complete all as specified and directed. 41 S&F load line distribution board TPN vertical, 6 way double door type, fixed on wall semi flush with incoming MCCB 4 poles and, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed. NOTE : Outgoing MCBs shall be measured and paid separately. 42 S & F of 125A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed. 43 S & F 40 W surface / wall mountedLED batten capable of delivering minimum 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. 44 S & F 9W LED Study light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz complete all as specified and directed. 45 S & F surface mound Flame proof LED Batten, 20W, CRI > 70, suitable for Hazardous area group IIA and IIB and zone 1 & 2, IP 65 Protection with 100 lumens/watt with Die Cast Aluminium Housing, THD < 15% complete all as specified and directed. 46 SEWAGE DISPOSALConstruction of Septic tank (for 10 Users) conventional type, designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Brick wall RCC M-25 in Roof Slabetc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.30 meter complete all as shown on TD drawings No CESZ/2019/TD-115 Sheets 1/4 to 4/4 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 47 Construction of Soakage wells excavation, in any type of soil, walls of honey combed masonry, RCC cover slab in M25, bat filling interconnecting pipes of DWC complete filled with brick bats of size 1.20 M dia X 3.00 M effective depth complete all as shown on TD drawings No SZ/TD-14 Sheets 1/1 and directed.NOTE : Necessary Earthwork shall be included in the quoted rate. 48 M&L for 200 mm (inner dia) DWCPE (SN-8) pipe as per IS:16098 (Part-I) with all fittings and laid in trenches and jointed complete all as specified and directed. 49 EXTERNAL WATER SUPPLYSupply, laying and testing of 150 mm bore ductile iron pressure pipe socket and spigot end, class K-7, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 50 Supply, laying and testing of 100 mm bore ductile iron pressure pipe socket and spigot end, class K-9, confirming to IS-8329/2000 blast furnace slag cement with portland cement properties suitable for push - on- joint with inside cement mortar lining, internal metallic zinc coationg and external black bitumen coating laid in trenches etc complete all as specified and directed. 51 M&L for construction of brick masonary valves pit of internal dimensions 900mm x 900 mm x 900 mm complete and fabrication of 3.0 mm thick MS Sheet cover and angle iron frame made out of 40mm x 40mm x 6 mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as shown TD Drawing all as specified and directed. 52 S& F Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 50 mm dia bore and fixing up in Water supply mains of size 150 mm dia complete all as specified and directed. 53 Supply and fix valve, reflux with by pass arrangement 150 mm (6) dia complete all as specified and as directed. 54 M & L for Trial bore of 200 mm dia below ground level in any kind of soil strata including hard stone/ boulder by deploying direct/reverse or universal method to achieve desired depth including cost of consumable stores like fuel,lubricants, bentonite mud, material and transportation of machinery etc., complete all as specified and as directed..NOTE : -(a) Erection and dismantling of boring plant including all arrangement for the transportation of boring equipment to site of work from the store of contractor at site and back are to be made by contractor at his own cost. All rates should be quoted for supplying the material at site of work.Pits for collection of water and water for drilling tubewell will be arranged by the firm/contractor at site his own cost.(b) Borewell to be done subject to permission by CGWB. 55 M & L for electro logging for identification of aquafier zone with report enterpretation, including fabrication of strata chart in wooden glass frame and strata box of size 1000x600x100mm made by woodshisham and 3mm glass in front of box for display in pump house complete all as specified and directed. 56 Reaming up to 350 mm dia for depth upto 60 mtr from ground level complete all as specified and directed. 57 Reaming up to 300 mm dia for depth from 60mtr from ground level to 110 mtr complete all as specified and directed. 58 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 250mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 59 S & F of including lowering in borewell ERW/ MS casing pipe electric resistant welded pipe with socket confirming to IS:3589 of 200mm dia and thickness 8mm including two coats of anti corrosive bituminous paint of approved brand complete all as specified and directed. 60 All as per Srl Item No. 16.41 here-in-above but slotted pipe as per IS: 8110 strainer complete all as specified and directed. 61 S & F of end cap of for 200mm dia MS pipe, complete all as specified and directed. 62 S & F of MS reducer socket of 250x200 mm dia to be fabricated out of 12 mm sheet plate with the housing pipe of 250 mm dia for fixing 250 mm dia MS pipe to 200 mm dia MS pipe, complete all as specified and directed. 63 S & F of well cap of for 250mm dia MS pipe complete all as specified and directed. 64 S & F of clamp of size 150mmx10mm of length 1.5mtr including MS nut bolts of 10mm dia and washer etc for supporting casing pipe complete all as specified and directed. 65 S & F of clamp of size 150mmx10mm of length 1.0 mtr including MS nut bolts of 10mm dia with washer etc for supporting column pipe complete all as specified and directed. 66 S & F Steel wire rope, PVC insulated of size 10 mm dia of suitable size/ length as directed with clamps, nuts & boltsand washers etc for holdingcolumn pipes/GI pipes of submersible pump set, complete all as specified and directed. 67 S & F of cage fabricated from strips of size 25x4suitable for protection of submerssible pump set with two coat of anti corrosive black bituminous paint, complete all as specified and directed. 68 S & F of flat submersible cable 3 coremulti stranded copper conductor of size 6 sqmm ISI marked, complete all as specified and directed. 69 Supply and filling pebels of size 6 to 10mm around the casing pipe of borewell including all lead and lifts free from dust dirt or vegetation manure, complete all as specified and directed. 70 Development of tube well with compressed air and after with 25% extra capacity pump by pumping muddy water of borewell using air compressor of 350psi , 600cfm pressure for required number of hours including fuel etc.,complete all as specified and directed. 71 Conducting following tests for the bore well to determine safe water pumping from government approved laboratory including submitting the report to the department, complete all as specified and directed :-(i) Yield Test(ii) bacteriological Test(iii) chemical test (systematic analysis) 72 S & F of FASD submerssible motor panel starter of capacity 7.5 HPincl overload,single phasing prevention, complete all as specified and directed. 73 Design, supply, installation, testing and commissioning Iron Removal/ water treatment Plant of capacity 40 Cum/Hr (8000 GPH) complete to achive the permissible parameters of of treated waterconsisting of 01 set multi grade filter, 01 set Oxidation Chamber, 01 Set of Chemical Dosing System for Soda Ash, 01 Set ofChemical Dosing System for Sodium Hypo-chloride. The plant incld allinterconnecting piping valves & other accessories incld necessary internal cabling, termination support stays, clamps, inlet & outlet pipe connection for filtration and back wash etc confirming to relevant IS, foundationworks as per OEM. The plant to be painted with 2 coats of non-toxic anti-corrossive epoxy paint (suitable for drinking water quality) inside and 2 coats of synthetic enamel over a coat of red oxide primer complete comprising of the followings :- Item Continued as 16.43 to 16.46 74 (a)Oxidation Chamber, vertical cylindrical type, fabricated vessel of suitable size as per IS-2062, incld pipe line 100 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge ,sampling cocks filled with Oxidation Chamber. Theshell thickness shall be of 6 mm and dished end having 6mm and bed plate under drain collecting system will be strainer on bed plate. Diameter of vessel shall be - 900MM and Height on Straight - 750MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 75 (b)Multi Grade Filter, vertical cylindrical type , MS fabricated vessel of suitable size as per IS-2062, incld pipeline 150 mm dia, butterfly valve of suitable size incld 2 nos. pressure gauge, sampling cocks filled with Sand media having 915 mm media depth. The shell thickness shall be of 6mm and dished end having 6mm with header and lateral collecting system. Multi Grade filter should have Epoxy paint from inside and outside red oxide paint. The shell shall also be provided with adequate size of air ventline with valve etc. Diameter of vesselof MGF shall be - 2000 MM and Height on Straight - 1875MM. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate). - 01 Set 76 (c) Chemical Dosing System (CDS-4 with High Speed Agitator ) for Soda Ash at raw water collection tank with electromagnetic metering run on 220 V AC for 100% accurate dosing with all electrical connections with 200 ltrs PVC tank- 1 No. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set(d) Chemical Dosing System (CDS-4 with High Speed Agitator) for Sodium Hypo-chloride after iron Removal Plant with electromagnetic metering pump run on 220 V AC for 100% accuratedosing with all accessories with 200 ltrs PVC tank- 2 Nos. (Necessary Civil work, foundation, PCC, RCC, excavation , returning and filling etc shall be deemed included in the quoted rate).- 01 Set 77 Note :- (i)Minimum working pressure of the plant shall be- 2 Kgs/Sqcm Maximum working pressure of the plant shall be - 3.5Kgs/Sqcm(ii) Backwashing shall be 30 minutes at an interval of 8 hrs.(i) Contractor has to carry out necessary water testing and design of the plant accordingly. Chemical / bacteriogical test of water has to be recorded and submitted by the contractor before & after filteration. (ii)All necessary pipes, flange, fittings, valves for bypass pipe line connection, and inter connetion the plantdeemed to be included to the quoted rate. 78 Supply, installation, testing and commissioning multi stage submersible pump setwith bronze impeller, directly coupled with motor, suitable for 200/250 mm bore well water lubricated against minimum total head 45 meter and discharge min 600 LPM operated on AC 3 phase, voltage range 200V-440V, 50 Hz. The motor casing shall be of stainless steel, pump shaft/ motor shaft shall be of stainless steel, pump bowls shall be of high graded cast iron all as specified and directed. The pump and motor shall comply to all the requirements of relevant IS. NOTE :The pump size, i.e head and discharge mentioned is minimum required at site, however, the actual size shall be arrived after doing necessary yield test. 79 Supply,installation, testing and commissioning open well Submersible pump of capacity 10 HP,electric driven 415 V, TPand completeinclusive ofsubmersible cable and starter including dry run preventor and single phasing preventor complete all as specified and directed. 80 M&L for DI fittings for spigot and socket pipes of size 80 mm to 350 bore such as bends(any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc)Tee pieces single branch, Yjunction, double branch, cross(all sockets or socket and spigot) collars caps and plugs complete all as specified and directed. 81 FIRE FIGHTING & FIRE ALARM SYSTEMSupply, installation, testing, and commissioning of Fully automatic DOL starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed. 82 M & L for 2 core, 2.5 sqmm (for instrumentation)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 83 M & L for 3 core, 2.5 sqmm (for auto start/stop panel)low smoke zero halogen (LS0H) flame retardant Fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica Fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed. 84 S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete all as specified and directed. 85 S & F ofCL 150 # rated ball valve25 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 86 S & F ofCL 150 # rated ball valve80 mm NB, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design, CS body, SS- 304 ball, PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection, etc. with accessories complete all as specified and directed. 87 M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI butterfly valve, 100 mm NB, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). 88 M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed. 89 S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. NOTES: [i] Operating temperature :-300C to + 550C[ii] Performance criteria : Discharge time not less than 45 sec , throw not less than 4 meters[iii] Hydro test and burst pressure test : Shall pass hydro test pressure of 35 bars 2.5 minutes and with stand a burst pressure of 55 bar 90 S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed:-Item Continued as 16.60 & 16.61 91 Sign of size 250 mm X 300 mm reading IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. 92 Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. 93 S & F Galvanised Iron Fire bucket 9 ltr Red in colourheavy duty all as specified and as directed 94 EXTERNAL ELECTRIFICATIONS & L 50 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 95 S & L 75 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 96 S & L 90 mm outside dia double corrugated pipe(DWC) ISI marked for enclosing cable below ground/road surface to a required depth including suitable size couplers for jointing of pipe all as per site requirement etc complete all as specified and directed. 97 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofand LT Fault Level 21KA , consisiting of 630A12 kV rated , 1 nos load break switchesas incomers &2 nos motorized type VCB as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar as per detailed description as follows:- Item Continued as 16.67 to 16.74 98 RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchboards drives shall have an IP2X protection index. The tank shall be made of at least 2mm unpainted stainless steel.SF6 gas is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered.SF6 gas used for the filling of the RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator. Number of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the SF6 enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only. 99 HT system : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. Enclosure of RMU must be IAC rated for 21 kA for 1 Sec. Design ambient to be considered as 40 Deg C.HT Circuit Breaker : i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall behorizontal isolation - horinzontal draw out type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2Aii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 1 secs. Iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%) , No. of Trip Coils - 02 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip Feature forseries trip shall also be enabled. iv) Provision for supervision of the two indepandent Trip Circuits for the two Trip Coils to be provided. v)Switchgear classification: PM classvi) Loss of service continuity class: LSC2A 100 vii) Duty Cycle : O – 0.3sec – CO – 3min – CO, Vacuum Circuit breaker shall be of M2, E2, C2 duty and capable for minimum 100 short circuit breaking operation at full short circuit level.viii) STC rating 21 kA for 1 Sec (for Vacuum Interrupter).ix)Vacuum Interrupter must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.xi) The Operating mechanism shall be spring charged motor operated type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.xii)Suitable monitoring of Circuit Breaker status ( ON, OFF, Trip, CB Spring Charged), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using IoT based online monitoring system using microprocessor / digital RTU with historical data saving, capable of updating status and sending alarm signal on IoT monitoring unit, GSM and GPRS platform through which live monitoring status and equipment reading and fault related history can be accessed by user remotely. 101 xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/CHT CT /PT i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 15 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 15 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV-6 kV /√3 / 110V/√3, Cl 0.2s, 100VACore 2- 11kV- 6 kV /√3 / 110V/3, Cl 3P, 50VA 102 Multifunction Meteriii) 2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments) .Protection Relayi) 2 Nos. of Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates. 103 ii) Master Trip Relay :High Impedance and High speed relay flush mounted having coil cut-off contact with at least 4NO and 4NC contact and electrical reset facility capable to make, carry and break trip coil current of Circuit Breaker and capable for future integration with SCADA.iii) Each VCB must have separate Anti Pumping Relay.Fault Passageindicator: 104 The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include:Fault detection - Phase to phase and Phase to earth faults.One potential-free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option –End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include:Phase fault thresholds configurable from at least 100 to 800 AEarth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds.Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 105 Earthing The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations.Separate line side Earth switches shall be provided in each HT Circuit ( against each VCB)RMU Bushing & Cable termination:It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cablesThe bushing should be conveniently located for working with cables specified and allow for the termination of these cables: -630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard.Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU. Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 400 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables ( for HT side) and at LT side runs of cables matching with outgoing MCCB current rating. 106 S&F 8.0 Mtr Long Hot Dip Galvanised Street Light Octagonal Pole with Foundation type Base Plate and Foundation Bolts and additional structural steel as reqd, dimentions of Pole as Top Diameter - 70 mm, Bottom Diameter- 130 mm, Section Length - 8000 mm, Thickness - 3 mm, Foundation type Base Plate (200 x 200 x 16 mm), Foundation Bolts - 4 Nos 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projects bolt length 100 mm , with Single type arm bracket 1500 mm long , top dia 70 mm , suitable for LED Street Light fitting. The Pole shaft shall have octagonal cross section and continuously tapered with single longitudinal welding all as specified and as directed. 107 M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed. 108 S&F factory made IP-65 (Dust and power jet Proof according to IEC 60529) opaque street light junction box of size 260 mm x 210 mm x 116mm made of high quality polycarbonate (shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact(IK 08) totally insulatedmade of halogen and silica free recyclable material, UV resistant having high grade gasket made of polyurethane with copper terminal , MCB SP 6 Amps rating 10 KA with locking arrangement and 2 Nos M40 size cable glandand one M32 size gland suitable up to 35 Sqmm cable etc complete all as specified and directed. . 109 S&F HT/LT made up of PCC block (1:3:6) type. C-1 using 20mm graded stone aggregated of size 900 mm x 300mm x 100 mm thick (45 Cm burried in ground) and properly painted as per approved colour Brown/Blue (HT/LT) and written both side with signed red colour paint( HT cable 11 KV orLT cable 1100 Volts) on Cable route marker including necessary excavation and earthwork complete all as specified and directed. 110 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :-(i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 400 Amp 4 pole 01 Nos breaking capacity 36 KA , MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA,, thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. MCB SPN 32 Amp02 Nos. Item Continued as 16.80 111 (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 112 Supply, installation, testing and commissioning outdoor type stainless steel (SS 304) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 304 sheet. The fixing of doubledoors shall be on SS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure). All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 304.Sliding handle and locking arrangement front and rear both side . Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 304 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 600 Amps rating 4 Nos. (ii) MCCB 400 Amps 4 pole breaking capacity 36 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-01 No.Outgoing :-(i) MCCB 100 Amp 4 pole 03 Nos, MCCB 63 Amp 4 pole 02 Nos breaking capacity 16 KA, MCCB 40 Amp 4 pole 01 Nos breaking capacity 16 KA thermal magnetic release with Icu = 100% & rated impulse with stand volta.(Vimp) 8 KV with over current & short circuit protec-tion having double insulation & positive insulation featers. (ii) Current transformer 100/5Amps class-1 15 VA - 1 Nos, Digital Ammeter with inbuilt selector switch -01 No, Digital Voltmeter with in built selector switch -01 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-1 Set Item Continued as 16.82 113 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 114 Supply, installation, testing and commissioning indoor type stainless steel (SS 316) cubical enclosure compartmentalizedexterior and interior mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc. The enclosure shallbe made of 2 mm thickSS 316 sheet. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. IP-55 class protection and mounted on channel 75 mm welded with panel of SS 316 with 04 Nos foundation bolt of size not less than20mm dia and 300mm long. The enclosure shall have provision of cable alley . Cable entry from bottom side including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked,1100 volts grade of appropriate size (but not less than 2.5 sqmm).Incoming :- (i) Aluminium busbar rating 150 Amps rating 4 Nos. (ii) MCCB 63 Amps 4 pole breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation-02 No ( for incomer mains and incomer DG supply) (iii) Onload change over switch 63Amps modular type - 01 nos(Note: Busbar will be connected at changeover output)Outgoing :-(i) MCCB 32 Amp 4 pole 03 Nos breaking capacity 16 KA thermal mag protection with Icu = 100% & rated impulse with stand voltage (Vimp) 8 KV with over current & short circuitpro-tection having double insulation & positive insulation, MCB TPN 40Amps - 02 Nos, 3 Phase timer switch 40 Amps- 1 Nos(ii) Current transformer 100/5Amps class-1 15 VA - 2 Nos, Digital Ammeter with inbuilt selector switch -02 No, Digital Voltmeter with in built selector switch -02 No and Modular Indication lamp for main incomer LED type RYB (set of 3)-2 Set (at both incomer MCCB)Item Continued as 16.84 115 All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands.The various feeders shall be indicated by font size not less than 20 mmletters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape.Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class B, old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel.The platform shall be such that it is of a height 45 cm above the nearest road level. 116 SEWAGE TREATMENT PLANT (STP)Design, Supply, Installation, testing & commissioning of PACKAGED Sewage Treatment Plant(NBF Model)of capacity 50,000 Ltrs per Day with FRP Intermediate Cum Treated Water Tank of 20 KL capacity and tertiary treatment based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) complete with Recirculation Pump(Non clog submersible type of capacity 9 m3/Hr, Motor-1HP, Head- 8m) - 01 No,Air Blowers twin lobe type of capacity 3.0 HP - 02 Nos, Filter feed pump (Non clog submersible type of capacity 18.0 m3/Hr, Motor-1 HP, Head- 15 m) - 2 Nos ,Pressure Sand Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosActivated Carbon Filter FRP based complete with connection pipes (capacity-3.0 m3/Hr, Max Pressure- 10 PSI)- 1 NosChlorine Dosing Pump of capacity 0-6 LPH- 1 NosMCC Control Panel ,FRP tank accessories , including all connecting PVC pipes and all others accessories and necessary civil works for installation as per recommendation of OEM.Note:-(a)The minimum life of STP shall be 15 years. A certificate from manufacturer shall be provided by the contractor.(b)The RCC Collection Sump of suitable capacity before STP and necessary pumping arrangement (as required) is deemed to be included in the rate quoted by the contractor.(c)All accessories required to achieve the outlet parameter shall be included in the quoted rate.(d)Necessary arrangements to accomodate the inlet sewer Pipe line as per invert level deemed to be included in the quoted rate.(e)The contractor has to get the design and other parameters for complete sewage system including STP approved from GE before placing of order for procurement 117 COOLING APPLIANCESSupply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 360 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 3 star rated including electric connection complete all as specified and directed. 118 Supply , installation, testing & commissioning of refrigerator, ISI marked electric driven , single phase having capaciy 310 ltrs or nearest higher size , frost -free smoothflow type seprate chill compartment with plastic shelves, Ice maker unit, vegetable/fruit drawer, body colour as approved with suitable lighting arrangement working with non-CFC refrigerant & 5 star rated including electric connection complete all as specified and directed. 119 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 01 KVA incl electric connection complete all as specified and directed. 120 Supply,Installation, testing and commissioning of copper wound volatge stablizer , ISI marked for automaticoperation , single phase, naturally air cooled, indoor type & designed for I/P variation between 170 V to 260 V with O/P voltage stablization at 230 V with accuracy of +/- 2.5% with high & low voltage cut out & time delay & of capacity 02 KVA incl electric connection complete all as specified and as directed 121 DG SETSupply, installation, testing and commissioning totally enclosed (silent operation with canopy, CPCB-IV+ complaint), static type deidel engine driven, liquied cooled, generating set of 30 KVA, 24KW capacity accommodated with accoustic encloser (at 0.8 lagging P.F), 415V,50Hz, 3 phase system & for 0.85 load factor , base plinth as per manufacturer recommendation, (A) Disel Engine:- Diesel engine shall be 4 stroke liquid cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at ambient temp of 50 dgree celcius, 50% RH & 1000m above MSL, electronic governer, confroms to BS:5514/ISO 3046, BS 649,IS 10000 with capacity of 10% overload for one hour in every 12 hours of continuous operation. The engine shall have noise limit of 75 dB(A The OEM shall undertake type approval and conformity of production certificate for emission standard for engine from agencies approved by GoI. Copy of the same shall be produced,(A1) Air intake system(i) Air intake manifold,(ii) Dry type air cleaner(A2) Exhaust system(i) Dry exhaust manifold with residental silencer and catalytic converter(A3) Cooling system(i) Engine water pump(ii) Radiator with fan(iii) coolant additive concertrate(A4) Lubricant system (i) Oil pan(ii) Engine mounted lube Oil pump (iii) Lube oil filter(A5) Starting System,(i) 12/24 V DC starter motor, voltage regulatorsItem Continued as 16.91 to 16.94 122 (ii) 12/24 V DC alternator for battery charging, (iii) 12/24 V suitable maintenance free battery of suitable capacity(A6) Engine mounted microprocesser based (perferably) instrument panel with digital display for the following:-(i) LED indicating lamps-for Genret running, remote start, shutdown, warning, manual, auto and stop(ii) Data Logs-engine run time and controller on time(iii) Start/Stop switch with key(iv) Indication/Display of for water temp, lub oil pressure, lub oil temp, battery charging,RPM, over speed, low lub oil trip, Engine hours(v) Engine and alternator data - startingf batter voltage, Engine running hours, engine temp, engine oil pressure, alternator voltage, current, KVA, frequency, KWH shall be displayed.(B) protection to Genret, (i) Low lube oil pressure warning/shutdown, (ii) High engine temp warning/shutdown,(iii) Low coolant temp warning, (iv) Sensor failure indication,(v) Low/High battery voltage warning,(vi) weak battery warning, (vii) fail to start shutdown,(viii) Cranking lockout, 123 (ix)High/Low AC voltage shutdown,(x) under/over frequency shutdown,(xi) loss of sencing voltage shutdown.(C) Others(i) AVM Pads, (ii) First fill of lubricating oils(iii) flywheel with housing(iv) Residental silencer,(D) Alternator synchronous alternator copper wounded rated 30 KVA, 415 volts, 1500 RPM,3 phase,50Hz,AC supply with 0.8 lagging power factor at 50 degree c, 50% RH and at 500 MSL, brushless type, self exicited, SPDP encl , contineous duty, voltage regulated through AVR conforming to IS:4722 with class F/H insulation. The sailent feature are as under: (a) Permanent lubricating beraing (b) Permissible overloading of 10% for one hour in every 12 hrs of contineous operation (c) permissible unbalancing capability minimum 25% per phase .(E) ACCOUSTIC ENCLOSER FOR DG SET :-S & F accustic enclosers suitable for 30 KVA capacity diesel generator set duly fabricated of channel and CRCA sheet 2 mm of required size having doors , insulation sides and top by minral rock wool confirming to IS-8183 of adequate thickness accoustic louvers / outlet ventilation system etc. complete as per manufacturers instruction with wiring and lighting arrangments duky painted of three coats of delux gloss synthetic enamelled paint over a primer coat or as directed of suitable size all as requried at site and comprising of the following:- (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section, (ii) Structure heavy duty rectangular MS box channel , (iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks, 124 (iv) Out side cover : Made out of 2 mm thick ,(v) Accoustic insulation(side & top) sound proffing mineral rock wool slab thickness 100 mm of density 96Kg/m3 confriming to IS 8183 , covered by fire resistant fiber tissue as per manufacturer recommendation. Test report from original manufacturer to be submitted before incorporation in the work authenticity of material, (vi) Inspection port : Aluminium frame with double walled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel. (F) FOUNDATION :- PCC Foundation M 20 ( or as per manufacturere design ) , 450 mm overall height , 300 mm above floor level and 150 mm below floor level of requried size. The price of foundation of DG Set is included in quoted rate. (G) FUEL TANK:- One no of sheet metal steel tank made out of 3.0 mm thick MS sheet of suitable capacity of hold diesel sufficient for 12 hours running at full load , tank shall be fitted with incanopy as per manufacturers design including the following:- (i) Level indicator to indicate level of diesel in tank,(ii) Drain plug with 2.0 mtrs pipe for drain oil, (iii) fuel strainer, (iv) pipe for fuel,(v) air vent. 125 NOTE:- (a) Generating set will be placed on suitable foundation as recommended by manufacturer and cost thereof shall be included on the prices quoted. (b) Tools shall be supplied as per manufacturers instruction and cost therof shall be included in the price quoted. (c) DG Set shall be placved at the site directyed by Engr-in-Charge. (d) Testing of DG Set shall be done as per relivant IS clause or min 10 hour running with 01 hour with no load, 02 hr with 25% load, 02 hrs with 50% load, 02 hrs with 75% load, 02 hrs with 100% load, 01 hr with 110% load. The required Fuel and artificial load/tools, etc to be included in quoted rate. 126 DEMOLITION & DISMANTLINGTaking down carefully old unserviciable DB including of any size/way complete including MCBs for keeping in safe custody or for taking credit all as directed. 127 Taking down carefully old unserviciable service cable of any size for keeping in safe custody or for taking credit all as directed. 128 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 129 Taking up or down from any position existing CI water tubing and connections carefully or for taking credit complete all as specified and as directed for 100 mm size 130 Taking down carefully old unserviciable sluice valve 100 mm for keeping in safe custody or for taking credit all as directed. 131 Taking down carefully old unserviciable sluice valve 150 mm for keeping in safe custody or for taking credit all as directed. 132 Taking down carefully old unserviciable gate valve 25 mm for keeping in safe custody or for taking credit all as directed.
Contract Date: Feb 12, 2026 Contract Value : 39.08 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
West Bengal View Result →
25.
Drinking Water Supply and Sanitation #9513897 Technical Bid
Tender for Kalpi Npp Water Supply Scheme District Jalaun Construction Of Intake Footbridge Wtp Oht Rising Main Distribution System And Electrical Mechanical Works Under Kalpi Npp Water Supply Scheme District Jalaun - W.T.P -Design (hydraulic and structural ), construction, (including topographical survey, geotechnical investigation and other Surveys as required) for specified capacity of WTP based on 20 Hrs. operation including inlet chamber, aeration fountain / cascade, inlet channels ,chemical building ,including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and flow measuring arrangement, clariflocculator with conventional, filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby ,safety equipment’s &EOTcrane,pressureandleveltransmitterfor pumpingplant,turbidity, TDS, PHAnalyzer,chlorineanalyzer,ROFTandLOHTforfilter house,flowtransmitterultrasonic/electromagneticatinletandoutletandFilter backwashwithentirepipingsystem , sludge handling unit and recycling of collected water from sludge , etc. complete to achieve desired perameters of clear wateras specified in tender document andin accordace letest C.P.H.E.E.O.Manual,/ltest guidline/ I.S. Codes/Govtt. Orders . All WTP scada Opratedexternal and internal electrification, laboratory building with all specified lab equipment, admin building,Sub station building (L.T./H.T. Room), Platform for Transformer,Meter Room ,chlorine Room,Staff Quarter (Type III-one Number), sanitary block with necessary water supply and drainage arrangement, campus roads (Interlocking Road/C.C.Road), landscaping( earth filling up to 115.00level including levelling and dressing of Campus )and other campus development works with rain water harvesting and garden, etc. all required works complete as per the direction of Engineer-in-Charge in Pile Foundation .The WTP shall be fully automatic prefrablybased onRapid sand gravity filter or any proven technologysuitable to treat Raw water from yamuna river throug out the year , PLC/SCADA with real time remote monitoring system and online contineuous effluent monitoring systemincluding Soil testing, Design ,S/o all labour ,material T&P etc. required for proper completion of the work as per letest IS Codes ,manuals ,instruction of engineer in charge and tender document. 2 INTAKE WELL- Supply of all materials, labour, T&P etc.as requiredforDesign and construction of Intake- well - cum - pump house of 9.0 m. internal dia. The intake well upto floor level shallbe firmly based on suitable foundation made with well sinking tecgnology including construction of coffer damand Annular raft/ well foundation , including construction of 1.20 m. wide R.C.C. balcony at plinth level, construction of Pump House made of brick masonry, duly embraced within R.C.C. column, and fitting of doors and windows, making opening arrangement at floor level of pump house (9.00 m. dia and 6 m. height)and construction of 1.20 m. wide R.C.C. balcony at Pump house floor levelincluding S.S. Rolling Shutter, steel cage hinged with locking arrangement, duly supported on steel girder. Plateform for transformer ,meter room andSubstation Building (HT pannel room,LT pannel room ) Ventilator arrangement along with fixing of required size dia. DID/F pipesand Sluice Valves- 3 Noat inlet etc. as per site requirement or as per the design. The work also includes steelrailing(grad 304 ) in three rows on both sides of pump house balcony and fixing of 0.5m. wide M.S. ladder made of 50 x 50x 6mm. angle iron ladder from floor of pump house to floor of intake well, duly supported on R.C.C.landing at suitable interval. The ladder shall run spirally inside the intake well and each landing shall be supported on R.C.C. M.S. channelpost, spaced not more than 1.5 m. interval including Construction of R.C.C. foundation block as required also include provision for dismantling and reinstatement of stone pitching,removal earth of Coffer dam to maintain flow through-out the year ,Approch roadup to Approch bridge etc up to completion of work as per insrtuction of engineer in charge and tender document . 3 The floor of pump house & balcony shall be of Kota Stone etc. complete. Frames for doors / Shutter shall be made of 50x50x5 mm. M.S. angle iron and ionized and shall be partly panelled and glazed, made of suitable steel sections, conforming to relevant BIS. The work also includes painting of all concrete surfaces with three coats of approved paint and painting of pipes, doors, windows with anticorrosive paints including design of intake well, foot bridge, pump house etc. considering seismic and other forces as per relevant BIS requirements. 4 Design and construction of 4.0 mts. wide R.C.C Foot bridge from Intake well to bank of river for length of 350 mtsminimum height of foot over bridgeslab should be equal to level of floor level of Pump House. pier of bridge in well shinking foundation minimum two Beam below deck slab with bearing support. Provision for padestal construction to rising main pipe fixing with anchor Clamping ,casing pipe for electric cables . Also including Supply& fixing ofstainless steel (gread 304) railing both sides of foot bridge , floor shall be plain chequered tiles, Statinless steel gate at entry gate of Approch bridge with locking arrangmentsup to completion of work as per insrtuction of engineer in charge and tender document . 5 Construction of R.C.C Over Head Tank (OHT)Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 and IS 11682 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911.Following capacity/StagingAll Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit asI.S. 456.Minimum depth of founditation below original ground level will be 2.0 M and in pile Foundation .Seismic effects and wind load should be taken into consideration as I.S. 1893for earthquake resistance and I.S. 875 part-III for wind load on structure. The asumed bearing capacity of soil has been taken as 8 M.T. sqm.1m wide RCC stair case from ground lavel to balcony.M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body (from manhole to tope domto bootom dome). 6 1 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. postsof 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.Electro Megnatic Flow Meter.Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consistproper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.including soil testing from govt institute as per tender document andrelevent IS codes. 7 Zone -1 1300KL/22M 8 Zone -21100KL/25M 9 Zone -3 2400KL/22M 10 Zone -4 300KL/25M 11 CONSTRUCTION OF R.C.C CLEAR WATER RESERVIOUR (C.W.R) CUM PUMP HOUSE OF VARIOUS AT DIFFERENT SITE Design & supply of allmaterial T&P etc and constructRCC CWR cum pump house offollowing capacity with HT, L.T and meter room, GI pipes railling consisting of 3 rows of 20 mm dia G.I pipe and angle iron posts of the dome periphery, S.S ladder from ground level to top of tank and inside the tank, locking device, ventilator, supply and fixing digital level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 150 mm semicircular drain around the tank, two coats of apex paint and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipes and valves etc all complete as per approved design and drawing.including soil testing from govt institute as per tender document andrelevent IS codes. 12 1200kl (MCWR) 13 Demolition of R.C.C Over Head Tank (OHT)Dismantling of ESRs of various capacities and heights using crane (10 MT capacity) and handing over M.S./ C.I./G.I. pipes, valves, bends, etc. to the Department. However taking steel reinforcement by the dismantling agency and other defung buildings like staff quarters, damaged pump house including removing dismantled materials from site and disposing them at suitable place as directed, etc. complete.Capacity of E.S.R. upto 2 lakh litres and staging upto 12 M heightZone -1 500KL/12M 14 Zone -2 -400KL/12M 15 Raw Water Rising Mains From Intake To WTPExcavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters. 16 500 mm DI K-7(yamuna river to WTP) 17 Supply of ISI mark DI K-7 S&S pipes (push on joints) with supply of allDI specials of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete 18 500 mm DI K-7(yamuna river to WTP) 19 Lowering, laying and jointing with ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position also fixing of pipe on foot over bridge, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. 20 500 mm DI K-7(yamuna river to WTP) 21 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete. 22 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm 23 -Air valves as per IS 14845 : 2000-100 mm 24 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge. 25 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm 26 Kinetic Double Air Valves-Air valves as per IS 14845 : 2000-100 mm 27 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 28 Providing reinforcementincluding cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar) 29 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 30 Sluice valve Chamber 500mm 31 Air valve Chambers -Air valves as per IS 14845 : 2000-100 mm 32 Rising MainsSupply of ISI mark DI K-7/K-9 S&S pipes (push on joints) of following with D.I. specials and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete 33 125 D.I K-9 34 200 D.I K-9 35 350 D.I K-9 36 400 D.I K-9 37 Excavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters.0 to 1.5 m depth 38 Lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. 39 125 D.I K-9 40 200 D.I K-9 41 350 D.I K-9 42 400 D.I K-9 43 Supply of following type ofDI valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. completeDouble flanged Ductile Iron Sluice valves as per IS 14840 : 2000./Air valves as per IS 14845 : 2000 including Sluice valve of Isolation 44 125 mm D.I D.F. 45 200 mm D.I D.F. 46 350mm D.I D.F. 47 400 mm D.I D.F. 48 25 mm D.I D.F. 49 50 mm D.I D.F. 50 80 mm D.I D.F. 51 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 /Air valves as per IS 14845 : 2000 52 125 mm D.I D.F. 53 200 mm D.I D.F. 54 350mm D.I D.F. 55 400 mm D.I D.F. 56 25 mm D.I D.F. 57 50 mm D.I D.F. 58 80 mm D.I D.F. 59 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 60 Sluice valve Chamber (MASONRY TYPE) 61 Air Valve Chamber 62 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 63 MS work in plain RCC incluiding bending supply wastage overlaping etc complete 64 Provision for crossing of Nalas/culvert for laying of pipe line usingsuitable dia. and length 0.60 m more than the outer width of nala, labour, T&P, necessary arrangement for diversion & pumping of water if required, barricading etc required for proper completion of work as per directions of engineer-in-charge.(up to 3.50m wide) 65 NHAI crossing by trenchless technologyProviding and laying of 700 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 400 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply distribution. 66 Railway crossing by trenchless technologyProviding and laying of 250 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 125 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply. 67 Dismantling of following type of road surfaces for laying of pipe line n work including sorting out of serviceable materials and disposal of unserviceable materials. 68 Bituminious Road 69 Cement Concrete Road 70 Re-instatement of following type of road surfaces after laying of pipe linework including supply of all materials, labour, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement. 71 Bituminious Road 72 Cement Concrete Road 73 Distribution Network .Supply of ISI Marked or its relevant code HDPE Pipes and Electrofusion specialsof follwing sizes (Dia in mm) with jointing materials, specials of sizes required during constructionas per latest I.S.Samandement upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer 74 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 75 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 76 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 77 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 78 Supply of ISI Marked or its relevant code DI K-7 Pipes and Specials of follwing sizes (Dia in mm) with jointing materials, during construction as per latest I.S amendement upto site of work included loading, unloading, cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer 79 D.I. K-7/ 200 mm 80 D.I. K-7/ 250 mm 81 D.I. K-7/ 300 mm 82 D.I. K-7/ 350 mm 83 D.I. K-7/ 400 mm 84 D.I. K-7/ 450 mm 85 Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relerelavent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. /Air Valve as per as I.S : 14845D.I. D/F Sluice valve/ Scour valve 86 25 mm. dia DI D/F 87 50 mm. dia DI D/F 88 100 mm. dia DI D/F 89 150 mm. dia DI D/F 90 200 mm. dia DI D/F 91 250 mm. dia DI D/F 92 350mm. dia DI D/F 93 Fire hydrant (80 mm dia.) 94 Excavation for pipe line trenches in Ordinary soil requiring use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50.m including supply of alllabour T&P etc complete and as per direction of engineer incharge. 95 Cartage fromstore to site of work for following size (dia in mm)HDPE pipes andElecrofusion Specialsand lowering the same into trenches and laying true to alignment and gradiant including testing of pipe lines cuttings of pipes for making up the length and making joints with electrofusion couplers, bands, tees, endcap etc. with electrofusion machinery including all jointing materials, labour, T&P etc required for proper completion of work. (excluding cost of trenching) 96 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 97 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 98 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 99 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 100 Cartage of DI K-7 pipes and specials of following size (dia in mm) , lowering them into trenches and laying true to alignment and gradiant including testing of pipe line but excluding cost of trenching including all supply of Labour T&P etc complete required for proper completion of work. 101 D.I. K-7/ 200 mm 102 D.I. K-7/ 250 mm 103 D.I. K-7/ 300 mm 104 D.I. K-7/ 350 mm 105 D.I. K-7/ 400 mm 106 D.I. K-7/ 450 mm 107 Carting of following size of Sluice Valves/ Scour Valves Fire hydrants & Air Valves from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete.D.I. D/F Sluice valve/ Scour valve/ air valve 108 25mm dia 109 50 mm dia 110 100 mm dia. 111 150 mm dia. 112 200 mm dia. 113 250 mm dia. 114 350 mm dia. 115 Fire hydrant (80 mm dia.) 116 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 117 Thrust Block 118 Supply of all matarial labour T&P etc and constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge . 119 Sluice valve chamber 120 Scour Valve Chamber 121 Air Valve chamber 122 Fire hydrant chamber 123 Flow Meter chamber 124 Provision for Nala/ Culvert crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 125 For crossing ofnalla/culvert upto 3.5 m wide(90mm dia to 110mm dia ) 126 For crossing ofRoad upto3.5 m wide(90mm to 110mm ) 127 For crossing ofRoad upto7.0. m wide(90mm to 110mm) 128 Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work 129 Interlocking tile 130 C.C Road 131 Bituminous Road 132 B.O.E Road 133 Reinstatement of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of required new matarials & reinstatement the same includng supply of labour T&P etc. required for proper completion of work. 134 Interlocking tile 135 C.C Road 136 Bitumenous Road 137 B.O.E Road 138 NEW HOUSE CONNECTIONMaking House Connectionwith Distribution main with elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe , including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches , fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. 139 In C.C. Roads 140 For 90 mm to 110mm dia 141 For 125 mm to 160 mm dia 142 For 200 mm to 250 mm dia 143 For 300 mm to 350mm dia 144 For 400 mm to 500mm dia 145 In Bitumenous Roads 146 For 90 mm to 110mm dia 147 For 125 mm to 160 mm dia 148 For 200 mm to 250 mm dia 149 For 300 mm to 350mm dia 150 For 400 mm to 500mm dia 151 In B.O.E. Roads 152 For 90 mm to 110mm dia 153 For 125 mm to 160 mm dia 154 For 200 mm to 250 mm dia 155 In C.C. Interlocking Tiles Roads 156 For 90 mm to 110mm dia 157 For 125 mm to 160 mm dia 158 For 200 mm to 250 mm dia 159 For 300 mm to 350mm dia 160 For 400 mm to 500mm dia 161 In Kacha Roads 162 For 90 mm to 110mm dia 163 For 125 mm to 160 mm dia 164 For 200 mm to 250 mm dia 165 For 300 mm to 350mm dia 166 SHIFTING OF HOUSE CONNECTIONMaking House Connection with Distribution mainwith elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe ,including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches ,fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. 167 In C.C. Roads 168 For 90 mm to 110mm dia 169 For 125 mm to 160 mm dia 170 For 200 mm to 250 mm dia 171 For 300 mm to 350mm dia 172 For 400 mm to 500mm dia 173 In Bitumenous Roads 174 For 90 mm to 110mm dia 175 For 125 mm to 160 mm dia 176 For 200 mm to 250 mm dia 177 For 300 mm to 350mm dia 178 For 400 mm to 500mm dia 179 In B.O.E. Roads 180 For 90 mm to 110mm dia 181 For 125 mm to 160 mm dia 182 For 200 mm to 250 mm dia 183 In C.C. Interlocking Tiles Roads 184 For 90 mm to 110mm dia 185 For 125 mm to 160 mm dia 186 For 200 mm to 250 mm dia 187 For 300 mm to 350mm dia 188 For 400 mm to 500mm dia 189 In Kacha Roads 190 For 90 mm to 110mm dia 191 For 125 mm to 160 mm dia 192 For 200 mm to 250 mm dia 193 For 300 mm to 350mm dia 194 Building worksSupply of all materials, labour, T& P, complete and construnction of a Half set of One No.Single Roomed staff quarters for Operator staff, pump operator, chaukidaar, pump attendent and other as per approved design in pile Foundation. 195 Zone-1 196 Zone-2 197 Zone-3 198 Zone-4 199 At wtp campus 200 Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation.For Construction of general resedential staff quarters(type-II) 1nos of 2 half set of area 57.70sqm. 201 Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation for Construction of following type of ancliary buildings Master Control Room(5x4.5x4m) 202 Construnction of Boundary Wall including supply all materials, labour, T&P etc required for proper completion of work as per Approved design in pile foundation. 203 Water Campus Zone 1 204 Water Campus Zone 2 205 Water Campus Zone 3 206 Water Campus Zone 4 207 AT wtp campus 208 Supply and fixing 3.60 M & 1.20 M wide MS Gate with pillars including fabrication and supply of steel and construnction ofboundary pillars etc complete. 209 Provide all materials, labour, T&P etc Required for proper completion of work and construct Interlocking Tiles approach road, laid dry and joints intact with coarse sand mortar including preparation of base etc 210 Water Campus Zone 1 211 Water Campus Zone 2 212 Water Campus Zone 3 213 Water Campus Zone 4 214 Construnction of Drain in Water works Campus30 x 30 cm including labour material and t&p all complete 215 Zone-1 216 Zone-2 217 Zone-3 218 Zone-4 219 Filling of earth of lower portion including levelling and dressing at water works 220 E&M works 221 RAW WATER PUMPING PLANT ATINTAKE WELL 222 Supply of Vertical type oil lubricated statically, dynamically, hydraulicallybalancedturbinepumpcapableofdischargingat980 rpm the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260with 2% NiCi with CF8M impeller running at 980 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer, Suction bell mouth, strainer, oil tube and 24mtr/suitablelengthcolumnassembly,withverticalSolidshaft Squirrel cage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuousratedTEFCIP-55withClassFinsulation,antirotation locking arrengementfor operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 6000 LPM / 35 Mtr. HEAD / 75 HP MOTOR (2w+1s) 223 MAIN PIPING AND VALVES :- 224 Supplyof250 mm dia DIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 225 SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67 (IP-68 for field installation),protectionclasssuitableforinstallation inanypositionwithout lubrication, leakage or other operational difficulty with special grease filledgearboxandsuitableformanualoperationforemergency which will automatically dis-engage on restoration of power to motor andwith10wattsinglephasespaceheaterandcontinuouslocal mechanicalpositionindicatorandindividuallyreplaceablecounter gear assembly and with two torque and four limit switches with S.S. flapandoperatedwithgeardrivencamsandofrating250Volt,5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADA operation sluice valve havingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI.Valvesare suitablefor hydrostatictestpressureof10Kg./Cm2forseatand15Kg./Cm2for body(PN-1.0)of following sizes 226 250 mm dia size at Pump delivery 227 350 mm dia size at common header 228 SupplyofDIDF manuallyoperatedsluicevalvehavingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass 229 Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -3 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 3 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -1 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot 230 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size 231 Dismantling joint 200 mm dia size at pump delivery 232 Dismantling joint 350 mm dia size at common header 233 Suitable capacity heavy duty handoperatedoverheadTravelling(HOT)crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 234 MOTOR CONTROL CENTER (MCC) PANEL :-Singlefront,Indoor&floormounted,cubicaltypePanelfactory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust andvermin proof IP-54 /IS:2147, consideredEarth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 3 No, Digital Amperemeter0-1000A -3Nos,CTFormeterResinCastCL- 1000A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION200 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 3 No, Spreader Links & Extended ROH for MCCB - 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 235 SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ampere meter, Voltmeter, indicating lamp6Nos,LEDON/OFFtypeandStart/Stoppushbuttonand InstrumentFuses,suitabletoSCADAoperationwithRS485Port rating capacity 75 HP / 55 KW 236 Supply & laying of 1.1KV grade XLPE insulated armured multi strand copperconductorcableof3Cx50sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I/ IS :7098 P-I) 237 Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm 238 Earthing with GI earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories, and providing masonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 :2018 239 Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) 240 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 241 Supply of CE/UL Certified Surge protector for control panel 242 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of 400 Amp 243 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. Compact SolarLED Street Light- 60W/12V/27Ah with GI pole 244 Internal & External electrification of Pump house :- 245 Twin tube light covered LED 20 Watt 246 450 mm dia exhaust fan 247 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 248 CompletewiringofPumphouse with1.5 Sqmm& 2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 249 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 250 INSTRUMENTATIONWORKS AT INTAKE WELL 251 Supply of CE/UL Full Bore Electromagnetic Flow Meter of approved makeoffollowing dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SS AISI 316L /Hastelloy C276/Tantalum,LiningMaterial:Hard Rubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard&Rating:ANSI150,Coilhousing:SSAISI304/Carbon Steel/DieCastAluminium, withanticorrosivepaint &provide completelysealed(leakproof)constructionasperrequirement ‘of IEC60529,Accuracy:+0.5%M.V.-velocity0.3to10m/s, Transmitter/signaconvertor Enclosure :DieCast Aluminium, Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable(size - 350 mm dia at common header) 252 SupplyofCE/ULCertifiedpressuretransmitterCEmarkdwith following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 253 Supply of CE/UL cirtified ofRadar level transmitter CE marked with following technical parametersand Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 254 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and PowerSupplywithanalogandDigitalParameterandfeaturesas specified tostoreandtransmitdataonGSMbackbone,RTU/PLC designedwithlogictotansferdataatmultiplestationsandalso compatible for satellite communication. 255 Control panel with IP 54 Protection, Industrial grade forall equipment and 24V and power supply 256 GSM/GPRS based wirelesscommunicationwith 4G modem for RTU/PLC Capable to transfer and gather data from remotesites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge 257 CE & UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters 258 CE/UL Certified Intelligent energy meters 259 Complete cabling for instrumentation works with power cabeling to panel of automation 260 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. 261 Installation, testing and comissioning of pumping plant & associated allequipmentsasperapproveddrawingshallbedonebybidder includingchequerredplateandpaintingofpumpingplant&main piping-valves. 262 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 263 CLEAR WATER PUMPING PLANT AT MCWR 264 SupplyofVerticaltypeselfwaterlubricatedstatically,dynamically, hydraulically balanced turbine pump capable of discharging at 1450 rpm thefollowingdutyconditionasgivenbelowduetoallcauseswith surfacedischargeheadconfirmingtoIS:1710andasamendedason datewithaccessoriesasperIS5120/1977(Reconfirmed2011)andas amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260 with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer,Suctionbellmouth,strainer,oiltubeand05mtr/suitable lengthcolumnassembly,withverticalSolidshaft Squirrelcage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class F insulation, anti rotation locking arrengement for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 5300 LPM / 50 Mtr. HEAD / 100 HP MOTOR (2w+2s) 265 MAIN PIPING AND VALVES :- 266 SupplyofDIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing 250 mm 267 SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67(IP-68 for field installation),protectionclasssuitableforinstallationinanypositionwithout lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which willautomaticallydis-engageonrestorationofpowertomotorand with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADAoperation sluice valve having Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0)of following sizes :- 268 250 mm dia size at Pump delivery 269 350 mm dia size at common header 270 Supply of DIDFmanually operated sluice valve having body Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass 271 Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -4 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 4 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -2 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot 272 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size 273 Dismantling joint 200 mm dia size at pump delivery 274 Dismantling joint 350 mm dia size at common header 275 3 Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 276 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dustandverminproofIP-54/IS:2147,consideredEarthBus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCBmicroprocessor baseed(O/C,S/C) release - 1 No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital MultifunctionMeter-1No,DigitalVoltmeter0-500V-1No,Digital Amperemeter0-400A -3Nos,CTFormeterResinCastCL- 200A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, ControlMCBSP6A,10KA-3Nos,CTShortingTerminal-4Nos, Neutral Link - 1 No.OUTGOING SECTION250 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 4 No, Spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 277 SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offeredforoperationinACthreePhase50Hz(+/-5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFFtypeandStart/StoppushbuttonandInstrumentFuses, suitable to SCADA operation with RS485 Port rating capacity 100 HP / 75 KW 278 Supply & laying of 1.1KV grade XLPE insulatedarmured multi strand copperconductorcableof3Cx95sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade coppe, purity >99.97 % ISI marked as per IS:1554 P-I / IS:7098 P- I) 279 Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm 280 EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 281 Supplyingandlaying50mmX12mmG.I.stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedone by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 282 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 283 Internal & External electrification of Pump house :- 284 Twin tube light covered LED 20 Watt 285 450 mm dia exhaust fan 286 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 287 Complete wiring of Pump house with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 288 Supply of CE/UL Certified Surge protector for control panel 289 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 290 INSTRUMENTATION WORKS 291 SupplyofCE/ULFullBoreElectromagneticFlowMeterofapproved makeoffollowingdiaandspecificationscomplete: Media: Water ( Chlorinated) , Pressure : up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316L /Hastelloy C276/Tantalum,LiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, withanticorrosivepaint&providecompletely sealed (leakproof) construction as per requirement ‘of IEC 60529, Accuracy:+0.5%M.V.-velocity0.3to10m/s,Transmitter/signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category-IP68forsensor(flowtube)andIP67fortransmitter/ convertor, including Surge Arrester, cable, of of following sizes :- 292 350 mm dia. Size at common header of pumping plant 293 350 mm dia. Size at OHT outlet of zone-1 294 350 mm dia. Size at OHT outlet of zone-2 295 450 mm dia. Size at OHT outlet of zone-3 296 200 mm dia. Size at OHT outlet of zone-4 297 Supply of Electrically Motor operated actuator with positioning card and bracketforsluicevalvesuitableforSCADAoperationwithlimit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable forOHT outlet of following sizes 298 350 mm dia. Size at OHT outlet of zone-1 299 350 mm dia. Size at OHT outlet of zone-2 300 450 mm dia. Size at OHT outlet of zone-3 301 200 mm dia. Size at OHT outlet of zone-4 302 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size 303 Dismantling joint 350 mm dia size at OHT outlet of zone-1 304 Dismantling joint 350 mm dia size OHT outlet of zone-2 305 Dismantling joint 450 mm dia size at OHT outlet of zone-3 306 Dismantling joint 200 mm dia size at OHT outlet of zone-4 307 Supply of CE/UL Certified pressure transmitter CE markd with following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 308 Supply of CE/UL cirtified ofRadarlevel transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 309 CE & UL Certified PLC/ RTU with redundent CPU & power supply in IP 54 enclosure suitable to communicate with GSMBasedmodemwith redundentCPU andPower Supply with analog and Digital Parameter and features as specified for each ZPSto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for CWR. 310 Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 311 GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for CWR & OHT 312 CE & UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 313 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligentGSMBasedmodemunit with CPU andPower Supply with analog and Digital Parameter and features as specifiedto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for OHT 314 Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 315 GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for OHT 316 CE/UL Certified Intelligent energy meters 317 Complete cabling of instrumentation equipments with power supply of panels for CWR & OHT 318 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. 319 Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done by bidder including chequerred plate and painting of pumping plant & main piping-valves. 320 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 321 11/0.44KV SUB STATION AT INTAKE WELL 322 Supply of star rated Copper wound distribution Transformer ( All the distributiontransformermustbestarratedaspernotificationof (BEE)ministryofpower,GoverenmentofIndia)offollowingrating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cablebox99.6 % & as per IS:1554 P-I / IS :7098 P - (I)from UPPCLmetering panel to H.T. Switch gear panel and panel to transformers 120 Sq.mm. size 326 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. 327 SupplyofH.T.Cableendterminationheatshrinkabletypeoutdoor joint kit 120 sq.mm. 328 Supply & laying of L.T. XLPE insulatedarmoured aluminium conductor cableof1.1KVgradeMaterial:-H4-Gradealuminium conductorofpurity>99.6%&asperIS:1554P-I/IS:7098P- (I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel and main LT panel to MCC panel of 3.5C x 300 Sq.mm. 329 Earthing with copper earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 330 Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) 331 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 332 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 333 NOC from electrical safety Dept. Govt. of UP 334 Fancing of substation in 2mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. 335 Internal & External electrification of HT & LT panel room :- 336 Twin tube light covered LED 20 Watt 337 450 mm dia exhaust fan 338 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 339 CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 340 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. CompactSolarLEDStreetLight- 60W/12V/27Ah with GI pole 341 Supplyofmicroprocessorbasedthreephasesensingpowerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor,lag/leadcapacitorswitchingstatus,alarmoutputforunder current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 100 KVAR 342 SITC of 01 No. DG Set of Capacity 180 KVA 415+ volt with AMF control Panel cabling,copper earthing etc. complete in all respect.( As per Lataest CPCB- IV Emission Norm ) 343 Installation, testing and commissioning of 11 KV /.44 KV substations includingH.T.panelandL.T.panelincludingchequeredplates,all labour T&P complete in all respect. 344 Testing of DG., Transformer, HT and LT Panel etc at Manufacturer Works 345 11/0.44KV SUB STATION AT MCWR 346 SupplyofstarratedCopperwounddistributionTransformer(Allthe distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+7.5% to - 15% @ 2.5%) temperature rise of 40 degree C inoil/45degreeCinwinding,ISImarkeddrainvalve,Dialtype Temperature gauge, OTI & WTI, marshalling box, first filling of transformer oil as per IS :335-1953, Epoxy based paint.Rating capacity - 400 KVA (1w+1s) 347 Supply of SCADA Compatible with RS 485 port 11KV,800 A, 25kA / 1 Sec, VCBIndoortypepanelHTboard,freestandingmotoroperated& withdrawaltypefabricatedfrom2mmthickCRCAsheetsteel,With copper busbar, Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection, 10 / 12-window Annunciation Panel, AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection(High oil temperature, Buchholz protection, high winding temperature, power pack 2 x 12 V,etc complete in all respect ready to use(RTU),OEM Must have BIS certificate incuding 1no incoming & 2 no outgoing VCB 348 Singlefront,Indoor&floormounted,cubicaltypeLTPanelfactory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION800 A, 50KA, TPN, ACB, EDOmicroprocessor baseed(O/C,S/C) release-2No SpreaderLinks&ExtendedROH -2No,3PhaseDigital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A -1No, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION400 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2 No, 200 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2No, spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 32KA- 2 Nos. Terminal 63A 349 Supplyandlayingof11/12KVgradeXLPEinsulatedH.T. armouerd cableasper IS:7098 / II/85,H4- Grade aluminium conductor of purity >99.6 % & as perIS:1554P-I/IS:7098P-(I)fromUPPCL meteringpaneltoH.T. Switch gear panel and panel to transformers 120 Sq.mm. size 350 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. 351 Supply of H.T. Cable end termination heat shrinkable type outdoor joint kit 120 sq.mm. 352 Supply & laying of L.T. XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 300 Sq.mm. (in 2 run for each transformer) 353 Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at WTP of 3.5C x 150 Sq.mm. 354 Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at MCWR of 3.5C x 400 Sq.mm. 355 EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 356 Supplyingandlaying50mmX12mmG.I. stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 357 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 358 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 359 NOC from electrical safety Dept. Govt. of UP 360 Fancing of substation in 2.5mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. 361 Internal & External electrification of Pump house :- 362 Twin tube light covered LED 20 Watt 363 450 mm dia exhaust fan 364 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 365 CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 366 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay&enclosure(Confirms to IEC:60947-1&IEC: 60947-6-1)of 630 Amp 367 Supplyofmicroprocessorbasedthreephasesensing auto powerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current,insufficientcompensation,communicationinterfacewithRS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 200 KVAR 368 SITC of 01 No. DG Set of Capacity 380 KVA 415+ volt with AMF control Panel cabling, earthing etc. complete in all respect. ( As per Lataest CPCB- IV Emission Norm ) 369 Installation,testingandcommissioningof11KV/.44KVsubstations including H.T. panel and L.T. panel including chequered plates, all labour T&P complete in all respect. 370 Testing of D.G, Transformer, HT and LT Panel etc at Manufacturer Works 371 Automation of DMA 372 Flow Control Valve 373 Supplying, installing ,commissioning & testing of Flow Control Valvefor inlet with flow measuring, flow controlling, pressure monitoringandweb based with cable PLC etc Complete.Pattern Hydraulically operated self actuated flow & level control valve (either with float or altitude pilot) with downstream orifice having Ductile Iron valve body, Y - Pattern, Double Chamber, unitized actuator, Fusion bonded epoxy coating, copper control tubing with Latching Solenoid & Pilot operated as per design, additional speed control feature, drip tight sealing, In-line serviceable, internals stainless steel & protected diaphragm suitable for drinking water. 374 For Zone -1 375 300 mm ( for OHT Inlet) 376 250 mm ( DMA-1) 377 250 mm ( DMA-2) 378 250 mm ( DMA-3) 379 For Zone -2 380 300 mm ( for OHT Inlet) 381 200 mm ( DMA-1) 382 250 mm ( DMA-2) 383 250 mm ( DMA-3) 384 For Zone -3 385 450 mm ( for OHT Inlet) 386 300 mm ( DMA-1) 387 400 mm ( DMA-2) 388 300 mm ( DMA-3) 389 For Zone -4 390 100 mm ( for OHT Inlet) 391 200 mm ( DMA-1) 392 IsolationValve 393 Supplying, installing ,commissioning & testing of DI Isolationvalve with electric acuator for isolation of DMA flow controling with cable PLC etc Complete. 394 For Zone -1 395 250 mm ( DMA-1) 396 250 mm ( DMA-2) 397 250 mm ( DMA-3) 398 For Zone -2 399 200 mm ( DMA-1) 400 250 mm ( DMA-2) 401 250 mm ( DMA-3) 402 For Zone -3 403 300 mm ( DMA-1) 404 400 mm ( DMA-2) 405 300 mm ( DMA-3) 406 For Zone -4 407 200 mm ( DMA-1) 408 Pressure Transmitter 409 Supplying, installing ,commissioning & testing of CE/UL Certified Pressure Transmitterfor pressure monitoring web based with cable PLC etc Complete for all 10 DMA,s of All 4 Zones 410 Electromagnetic Flow Meter 411 Supplying, installing ,commissioning & testing of CE/UL Certified Electromagnetic Flow Meterfor Flow monitoringweb based with cable PLC etc Complete 412 For Zone -1 413 250 mm ( DMA-1) 414 250 mm ( DMA-2) 415 250 mm ( DMA-3) 416 For Zone -2 417 200 mm ( DMA-1) 418 250 mm ( DMA-2) 419 250 mm ( DMA-3) 420 For Zone -3 421 300 mm ( DMA-1) 422 400 mm ( DMA-2) 423 300 mm ( DMA-3) 424 For Zone -4 425 200 mm ( DMA-1) 426 Residual Chlorine Analyser 427 SITC of Chlorine Analyser with MODBUS RTU having Following specification - (a) FRC senser range 0-5 ppm (b) Analyser with RS 485 O/P suitable to OHT distribution line and compatible with SCADA system toofor all 10 DMA,s of All 4 Zones 428 Chlorine Dozer For DMA 429 SITC of SCADA Compatible Chlorination Systemfor all 10 DMA,s of All 4 Zones 430 SCADA For DMA 431 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit with CPU & Powersupply with annlog & digital parameter & featuers as specified, for each DMA to store and transmit dataon GSM backbone, RTU/PLC desgined with logic to transfer data at multiple stations with control panel as specified intender technical specifications. 432 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories include with signal enhancer antenna made for pumping plant internetcharges as specified in tender technical specification . 433 Intelligent energy meters 434 Control Panel with IP 54 Protection, Industrial Grade for all equipment. (Separate for control (24 V) and power equipments.) upto 3 pumps. 435 CE/ UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 436 CE/UL Certified 1 KVA UPS with Batteries for data backup. 437 CE/UL Certified 10 KVA UPS with Batteries for valve operation of each OHT . 438 Cabling 439 Complete Cabling for Intake well including all power & control cable of all equipments at ZPS and OHT. 440 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories . 441 MASTER CONTROL STATION (MCS) AT WTP 442 CE/UL & BIS Certified industrial grade LED MONITOR with latestconfiguration as per specification 65 443 Video call media player of same OEM 444 Core i7 10th gen Desktop/ laptop with 32 GB RAM and 256 GB SSD + 1TB HDD 445 CE/UL Certified 5 KVA UPS with Batteries required for mentioned work wih 01 hrs backup 446 Full Development version of TAGS SCADA software with costomization of software for MCS for unlimited digital and analog Input / output features as per requirements 447 CE/ULcertifiedmastercontrolroomPLCwithredundantCPU&power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect 448 CE/UL certified Field gateway agent for transfering data forMCS/control room 449 GSM/GPRSbasedwireless/Broadband/equivelentcommunicationsystem for PLC Capable to transfer and receive data & gather data from remote sitestocontrolstationsallaccessoriesincludedwithsignalenhancer,antenna along with running expences 450 CE/UL certified Firewall for network protection 451 CE/UL Certified Surge protector for Ethernet communication protection 452 CE/UL Certified industrial grade Ethernet switch 453 Mobile app facility system architecture (industries internet based & viewed through mobile apps for increasedblocal & remote visibility) 454 Canon/HP or equivalent Laser Printer 1018 or equivalent. 455 Hp or equivalent multifunctioning Laser Printer with scanner 456 BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer 457 Office furniture ( office table - 2 No, revolving chair- 2No, Office chair-3 No, Godrej almirah - 1No) 458 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories. 459 Installation, Commissioning and testing of all above equipments for MCS with all power cables 460 TRAIL & RUN FOR 3 MONTHS WITHOUT ELECTRICITY CHARGES
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
26.
Housing Urban and Rular Development #9468305 Technical Bid
Tender For Rates For Material/Equipment Regarding Medical Gas Pile Line System And Modular Operation Theatre For Estimate Preparation. - Rates for Material/Equipmentregarding Medical Gas Pile Line System and Modular Operation Theatre for estimate preparation. 2 Medical Gas Pipe Line (Part-A) 3 Oxygen Manifold 4 SITC of 10 + 10 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders. as per specification (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 5 Certifications: ISO 13485:2016,ISO 9001:2015, CE 6 Fully Automatic Oxygen Gas Control System 7 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 8 Oxygen Flowmeter with Humidifier 9 Essentia medical gas flowmeters are designed to measure and regulate flow.These are calibrated to specific gas & flow range. Oxygen flowmeter is intended for use with various delivery system when bubble/ micro bubble humidifier is attached downstream. These flowmeters are widely used in home care, health centers, district/ general/ regional hospitals, tertiary care, emergency vehicles etc. for administration of supplemental oxygen through nasal cannula, simple face mask,partial rebreathing mask, non re-breather mask, resuscitation mask etc. A passive process to humidify dry therapeutic gas (Category 3 Humidification) Micro Bubble Humidifier for Respiratory Therapy Patient connection port : Tapered hose barb suitable for 6 mm inner diameter plastic tubingMicro bubbles through humidifier for efficient humidificationPossible to integrate into an oxygen concentrator, sleep apnoea therapy equipmentOptimal RH achievable at various flow settingsAutoclavable at 121°C (249.8°F) for 5 minutes (Minimum 5 autoclave cycles)Over pressure safety valveNon-heated and reusableInlet connection port : DISS female adapter with chrome plated Brass nut embedded in ABS for hand-tighteningFlow : Up to 15 lpm @ 4 bar (58 psi)Construction material: Polycarbonate - shatter resistantCapacity - 240ml at max water level (Jar 450ml)Make- Altos/Aktiv or Equivalent 10 Emergency Oxygen Manifold 11 The oxygen cylinder manifold should comprise of two cylinder Banks which can accommodate 6 cylinders in each Bank (means 6+6) complete with copper tail pipes with bull nose fittings of RH External threading suitable for cylinder valves (Oxygen service) and Cylinder support system. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves. High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Make- Altos/Aktivor Equivalent 12 Fully Automatic Oxygen Gas Control System 13 SITC of Fully Automatic Oxygen Control Panel for main Oxygen Manifold having constant flow output of over 2100 LPM or more at 55 to 60 psig Pressure. A test certificate shall be provided with each system detailing the results of the factory tests ,It should have halogen polymers free. It should have Digital 3.5’ colorful display. It should have Integrated & protected test point. Central regulators panel with cylinder headers each side. It should have headers which shall be complete with gas specific cylinder tailpipes. Pre-wired for alarm connection to BMS outputs. All components degreased for oxygen use .Average gas consumption indication (for not liquefied gases). Remaining gas volume indication (for not liquefied gases). It should have general maintenance indicator. It should have Pressure transmitters monitor both banks of cylinders & as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 14 MEDICAL NITROUS OXIDE SYSTEM 15 Nitrous Oxide Manifold 16 SITC of 4 + 4 size main manifold complete with middle frame with chain for individual cylinder along with Non Return Valve for every cylinder.All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders.. as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make-Altos/Aktiv or Equivalent 17 Fully Automatic Nitrous Oxide Gas Control System 18 SITC of Fully Automatic Control Panel for Nitrous Oxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel. It should fully complies and meets with the requirements of the NFPA-99 standards. It should be UL or ETL Listed. The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 19 Emergency N2O System 20 SITC of 2 Cylinder Emergency Nitrous Oxide manifold with All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders using a high flow Preset Pressure Regulator as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- Altos/Aktiv or Equivalent 21 MEDICAL CARBON DIOXIDE SYSTEM 22 CARBON DIOXIDE SYSTEM 23 The CO2 cylinder manifold should comprise of two cylinder Banks which can accommodate 4 cylinders in each Bank (means 4+4) for cylinder valves conforming to IS 3234 (CO2@ service) complete with copper tail pipes with fittings. Manifold should be suitable to withstand a pressure of 140 Kg/cm2, along with high pressure copper annealed tail pipes with Brass adapter suitable for Nitrous Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 1/2I.D. x 15swg with high pressure brass fittings made of high tensile brass and connections through non- return valves.High pressure copper tail pipes, made of high pressure copper pipe of size 1/4I.D. x 15 swg.The middle and bottom frame to be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 250kg / cm sq. The copper tail pipes are fitted to the individual non return valves of the cylinder manifold for easy removal of cylinders without disturbance to system operation. Each manifold should be provided with one terminal header and a NPT connection for the Automatic control panel. Make- Altos/Aktiv or Equivalent 24 Certifications: ISO 13485:2016,ISO 9001:2015, CE 25 Fully Automatic Carbon DioxideGas Control System 26 SITC of Fully Automatic Control Panel for Carbon dioxide having constant flow output of over 500 LPM at 4.2 Bar Pressure. Digital Fully Automatic Control Panel.The manifold control panel shall consist of two bank regulators (dome bias) used to reduce the cylinder pressure to the two line regulators which in turn controls the final line pressure. The manifold has an intermediate and line relief valve that is internally connected to a common vent port, terminating into a 1/2 FNPT pipe. It should be fully automatic type and shall switch from “Bank in Use” to “Reserve Bank” without fluctuation in the final line pressure. After the switchover, the “Reserve Bank” shall then become the “Bank in Use” and the “Bank in Use” shall become the “Reserve Bank.” The control panel includes a line gauge, two bank gauges and incorporates six LED’s: two green for “Bank in Use,” two yellow for “Bank Ready” and two red for “Bank Empty” on the front of the cabinet. Input power to the manifolds is 110 to 240 VAC, 50-60 Hz& as per specification. (Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Micro processor controlled switch-over is accomplished automaticallyAutomatically resets itself for next cycle when depleted bank is replenished. No manual resetting requiredDigital pressure indication for accurate readingPressure unit options: bar, psi & kg/cm Status indicatorsPressure Stabilizer for stable discharge pressure & flowVisual & Audible signalDesigned to suit CO2 for gas specific usageOptimized residual gasMake-Altos/Aktiv or Equivalent 27 Emergency CO2 System 28 The Emergency supply manifold shouldbe connected to downstream of the manifold control panel.The assemblyshould consist of 2 (two) cylinders connection supplying a manually adjusted regulator via a common header assembly. The delivery system is isolated from the main system by an isolation valve. Pressure gauges should indicate cylinder and delivery pressure & valves conforming to ISO 13485Make- Altos/Aktiv or Equivalent 29 MEDICAL VACUUM SYSTEM 30 SITC of MEDICAL VACUUM SYSTEM AS PER SPECIFICATION 31 Vacuum Pump : The arrangement should consist of 2 nos. of oil lubricated imported rotary vane vacuum pump. Each vacuum pump should have capacity of 5000 lpm with IEC Motor rating of minimum 10 HP @ 50 Hz or above. Vacuum pumps shall comprise of air cooled, oil lubricated rotary vane vacuum pumps suitable for both continuous and frequent start / stop operation at inlet vacuum vessels between 525 mm Hg and 700 mm Hg. The ultimate vacuum of pump shall be 0.1 mbar with gas ballast valve closed. The Vacuum Pump should be air cooled and oil lubricated rotary vane vacuum pumps designed for use in the field of high quality vacuum. It should be a robust construction, reliable operation, highly resilient carbon composite fiber vanes, Gas ballast valve. The pump should be having a 4 barriers system that avoids any oil leaks by doubling the 2 lip / shaft seals. Pump vanes shall be lubricated by a fully re-circulated and filtered lubricant supply. Also Pump design should include a lubricant separation system integral to the pump exhaust box consisting of no less than four stages of internally installed lubricant and smoke eliminators through which the exhaust gas stream must pass. This system shall consist of bulk separation, lubricant mist elimination, smoke elimination, synthetic lubricant baffle, and shall be capable of removing 99.9 percent of all lubricant and smoke particles from the exhaust gas stream. The unit should have extremely low vibration as per specification.(Mandatory submission--> 100% technical complaince sheet should be submitted with the technical bid from original manufacturer.)Make- multitech/hitachi/Anistaiwata or Equivalent 32 Vacuum Tank of 5000 liters water capacity.Make- multitech/hitachi or Equivalent 33 Bacterial Filter:Vacuum Filter (Bacteria Filter) of 100 cfm to 105 cfm – 3” Filter housing with drain flask.: It fully complies and meets with requirements of UK HTM medical standards. It should have BS 3928 sodium flame test certificate based on requirements of HTM standards.The bacteria filter should be designed for critical application involving removal of dry and wet dust, particulars, oil aerosol and water droplest, high efficiency glass fiber, fieece media from suction side of vacuum pump system. It should have efficiency of at least 99.995% when tested by sodium flame test and that should be according to BS 3928:1969. The Vacuum filtration efficiency should be in excess of 99.9999% as per HTM0201 & AS 2896 standards. The high efficiency medical grade filter element should have custom engineered filter media and deep pleat element technology provides minimal pressure loss and filtration efficiencies. It should have advanced filtration technology for Low pressure loss borosilicate glass microfiber-media and open cell reticulated foam pre-filtration layer captures particulates, bacteria and liquid aerosols reducing energy consumption and overall system costs. It should have corrosion protection Internal and external electrophoretic painting followed by a tough exterior polyester powder coating.It should have easily removable sterilisable drain flask and differential pressure monitor gauge. It should have push fit element design for quick and easy maintenance with unique push fit element design. It should have element end cap color black. It should have maximum temperature 60 degree centigrade (140 degree F). It should have element of E31140MV grade. It should have pipe size connection 1” = 105scfm and 180nm3/hr FAA. It should have pressure loss clean & dry = < 3kPa (30m/bar/0.44psig). It should have maximum working pressure 0.5barg(7psig. It should have manual drain valves and 250ml sterilisable glass drain flasks.(Maximum tolearance allowed will be only 10%).Smooth mobility.Sturdy trolley mounted on 5 castor base wheels.Operational when connected to centralized vacuum.Fast connection to the vacuum source.Various Vacuum Connector options.Controllable & Stable vacuum for procedure.Step-less vacuum regulation within the range.Gauge needle with anticlockwise movement .Vacuum trap with bacterial filter in series to protect.system networkDisposable hydrophobic filter element.Quick hassle-free replacement of bacterial filter.Switch toselect collection jar & quicksuction shut-off.Easy access to selector switch.90 degree angular interface connectors to push-fit catheters.Autoclavable Polycarbonate collection jars.Overflow prevention trap on each collection jar.Make- Tridentor Equivalent 34 Ward Vacuum Unit with Regulator, Collection Jar of 1000 ml with Bracket.Make- Altos/Aktiv or Equivalent 35 Theatre Vacuum Unit mounted on Trolley consisting of Vacuum Regulator with Gauge and 2 nos. of 4000 ml Polycarbonate.Make- Altos/Aktiv or Equivalent 36 Bacteria Filter (Plastic) for 100 ml Safety Trap before Vacuum RegulatorMake- Altos/Aktiv or Equivalent 37 COMPRESSED AIR SYSTEM 38 SITC of COMPRESSED AIR SYSTEM AS PER SPECIFICATION 39 Oil Free Scroll Air Compressor: The arrangement should consist of 2 nos.oil free scroll air compressor. It should be rated for 50 Hz, 3 Phase, 415 VAC power supply. Motor rating of each compressor should be 22 Kw & 30 Hp. Each scroll compressor should have a flow capacity of minimum 73 cfm (2070 LPM). The scroll air compressors shall be air cooled. Compressors shall be oil free scroll compressors suitable for both continuous and frequent start/stop operation having outlet pressure control range of 800 to 1000 kPa (8 to 10 bar). Each compressor shall have at least two individual scroll elements. The air quality shall be 100% oil free, certified ISO8573-1. The compressor shall have a sound insulating enclosure. Each scroll air Compressor should have an element consists of a fixed scroll shaped housing and a scroll shaped rotor. Air enters the compressor element through inlet opening. Once the air is drawn in, the orbiting scroll seals the inlet opening and forces the air into a continuously decreasing space. As scroll keeps orbiting, this process of compression is constantly repeated, resulting in discharging of oil free compressed air through outlet opening. Air is drawn through air filter and should be compressed by the compressor element of each compressor module. The compressed air is discharged via the check valve and a common air cooler. The cooling air is blown over the compressor element via a duct. A separate electric fan provides cooling air for the common air cooler. Each set of compressor modules has its own common aftercooler with an electric fan. The separator on compressors without integrated dryer has an automatic condensate outlet and a manual drain valve. The air compressors with integrated dryer, the dryer is equipped with a trap with an automatic condensate outlet and a manual drain valve. Each compressor element is protected by a sensor in the outlet pipe. The sensor is connected to the electronic regulator. Make- multitech/hitachi/Anistaiwata or Equivalent 40 Air Receiver of 5000 Liter Water Capacity (designed to withstand pressure of 10 Bar) with Auto Drain ValveMake-multitech/ hitachi or Equivalent 41 Medical Breathing Air Dryer- 375 SCFM - Medical air dryer heatless with purification modules are intended to provide a continuous supply of medical quality air conforming to the European Pharmacopoeia medicinal air monograph (ref. 1238), for respiratory use in healthcare facilities. The system shall be duplex such that the supply is maintained in single fault condition. Medical compressors shall be provided such that the specified volumetric flow is achieved without standby or backup systems running. Purification Module : The duplexed filter and dryer module shall incorporate high efficiency oil coalescing filters, heatless regenerative desiccant dryers, activated carbon filters and bacterial filters. The performance of the filters shall be according to below specifications: Oil coalescing high efficiency filter: mass efficiency of 99,92%, tested according to ISO 8573-2 & ISO 12500-1; Activated carbon filter: max remaining total oil content of 0,003 mg/m³, tested according to ISO 8573-5 & ISO12500-2;Bacterial filter: particle count efficiency of 99,98% at MPPS=0.06μm, tested according to ISO 12500-3. Dryer Purge Control : The dryer control system shall incorporate a Purge Saver Energy Management system that freezes the regeneration of the desiccant once adequate dew point is reached in the inactive tower. Only when the dewpoint level in the active tower deteriorates to an unacceptable level will the intelligent controller switch towers.Coarse coalescing filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of red color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 1 micron. It should have maximum particle size class 2 micron as per ISO 8573-1: 2010 . It should have maximum oil content 3 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68 degree F (20degree centigrade) = 0.3ppm (0.3mg/m3). It should have pressure loss clean & dry = 0.8psi (55m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). 42 Fine coalescing filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of blue color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.01ppm (0.01mg/m3). It should have pressure loss clean & dry = 1.2psi (85m/bar). It should have pressure loss saturated = 1.8psi (125m/bar). Activated Carbon Filter of 375 SCFM (one working and one as stand by) flow capacity: It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element end caps of black color for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have maximum particle size class 1 micron as per ISO 8573-1: 2010 . It should have maximum oil content 1 micron ISO 8573-1: 2010.It should have maximum oil carryover at 68degree F (20degree centigrade) = 0.003ppm (0.003mg/m3). It should have pressure loss clean & dry = 1.7psi (115m/bar). 43 Fine Dust Filter of 375 SCFM (one working and one as stand by) flow capacity : It should have flow-optimized design for advanced filter head design for optimized flow performance. It should have flexible installation Modular design and accessible fixings enable simple close coupling assembly. It should comply with air quality standard ISO 8573-1: 2010. It should have profiled bowl design and push fit elements ensure quick and for reliable maintenance. It should have corrosion protection Internal and external electrophoretic paint finish followed by a tough exterior polyester powder coating. It should have color coded element blue color end caps for easy and accurate grade identification. It should have element of E30612 grade.It should have particle retention of up to 99.999%, and significantly reduced pressure loss. It should have particle removal 0.01 micron. It should have pressure loss clean & dry = 1.5psi (100m/bar). Make- Trident or Equivalent 44 Pressure Reducing Station for 4 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 4 bar for medical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 4 bar stations - 5.5 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 10000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 45 Pressure Reducing Station for 7 Bar: The compressed air system shall be supplied with duplex pressure regulator arrangement to regulate the line pressure from 10 bar to 7 bar for surgical air. Adequate number of isolation valves should be provided to isolate each regulator separately during maintenance without shutting down the entire compressed air system. Presssure Regulators should be 28 bar rated. Brass pressure relief valve, 1/4 thread BSP should be provided after the regulator. Pressure Gauge of range 0 to 11 bar to be provided to monitor line pressure. Relief Valve Settings : Nominal 7 bar stations - 9 bar relieving.The Pressure Reducing Station should be capable of delivering minimum 4000 LPM flow.It shall be duly CE marked to the Medical Device Regulations and under this regulations, med gas products are classified as Medical Devices. 46 SITC of Medical Gas Outlets- 47 Probes are crucial for gas specific and stable connection. These are used to connect medical gases and vacuum devices to outlets / terminal units of MGPS distribution network.Make- Altos/Altos/Aktiv or Equivalent 48 FeaturesSmooth quiet action.Safe keying configurations.Gas specific ISO 32 colour coding.Firm locking of connector / probe.Strong, positive and secure connection.Corrosion-free and material compatibility.Reliable and safe dispense of gases & vacuum.Pipe stub end flared to align drop pipe and to avoid butt joint. 49 Oxygen 50 Air-4 51 Air-7 52 N2O 53 AGSS 54 Vacuum 55 CO2 56 Certifications:ISO 13485:2016 – Medical devices,ISO 9001:2015 57 MISCELLANEOUS ITEMS 58 SITC of Common Electrical Control Panel for Compressed Air System, Vacuum System & AGSS as per requirementcomplete with plant room wiring. 59 SITC of Degreased Medical Grade Copper Pipe as per EN 13348 :2018. BSI Kite Mark certified. CE Certified. Third Party Inspection by TUV or Lloyds Registrara AsiaMake- Altos/Altos/Aktiv or Equivalent 60 Installation of piping should be carried out as per international standards with utmost cleanliness. Only pipes, fittings and valves which have been degreased as per International standards should be used . Pipe fixing clamps for upto 28mm diameter. Pipes should be non ferrous suitable for the diameter of the pipe. For the pipes of the sized above 28mm rigid metallic hanging or cemented supports to be used. 61 The main lines to the building to be taken overhead through metallic poles or through underground ductswith inspection removable slabs,All pipe joints should be made using inert gas fluxless brazing method.Alljoints should be of copper to copper and should be brazed by silver brazing filler material without flux while being brazed joints shall be continuously purged with oil free dry nitrogen to prevent the formation ofcopper oxide on the inside surface of the joint.All pipes should be installed without springing or forcing.All pipes shouldprotected against mechanical injury in a manner satisfactory to authorities havingjurisdiction. 62 Test: After erection, all the new pipes cleaned or purged with the help of dry nitrogen gas.Complete system should be tested with dry nitrogen at 2 times of working pressure for 24 hours. 63 Painting: All existing and proposed exposed pipes/should be painted with two coats of Synthetic enamel paint & color codification as per international standards.All concealed pipes to have gas identification bands / labels at appropriate distance.Similarly all pipes which need embedding in the wall should be tested/painted/labeled and properly insulated. 64 Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS: EN 13348. 65 All copper pipes will beUL certified for medical use before dispatch and the pipe will be delivered plugged or capped at both ends. 66 108 mm OD X 1.5 mm thick 67 76 mm OD x 1.5 mm thick 68 54 mm OD x 1.2 mm thick 69 42 mm OD x 1.2 mm thick 70 35mm OD x 1.2mm thick 71 28 mm OD x 1 mm thick 72 22 mm OD x 1 mm thick 73 15 mm OD x 1 mm thick 74 12 mm OD x 0.7 mm thick 75 SITC of Medical Gas Digital Area Alarm System 76 Microprocessor based digital LCD alarmHighly visible 7 (178 mm) LCD screenPressure sensing through piezoresistive sensing technologyAlarms can be monitored audio-visualTouch screen operationComprehensive monitoring of all the medical gas alarm panelsData display at a central monitoring station Features-Alarm status will be visible through ethernet port on master alarmPressure Equipment Directive 2014/68/EUDigital Flow Care Alarm Management of Medical Gas Pipeline SystemReal time updating of statusOperational parameters i.e. high and low level canbe set “in-situ” to suit requirement in an area 2Programmable pressure unit display (bar, kg/cm & mmHg)Audio mute optionDesigned to serve 2, 3, 4, 5 & 6 gases including VacuumNIST connection for Gas inputPowered by 220V AC to 24V DC external adapterMake-Altos/Aktivor Equivalent 77 Conforms to: IS / ISO 7396 - 1 : 2016 + A1 : 2017HTM 02-01 Part A, IS / ISO IEC 60601 - 1 : 2015 + A1 : 2020Certifications:ISO 13485:2016 – Medical devices – Quality Management SystemsISO 9001:2015 - Quality Management Systems 78 6 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar, Vacuum & CO2) 79 5 - Gas (O2, N2O, Med Air-4 Bar, S Air-7 Bar & Vacuum) 80 4 - Gas (O2, N2O, Med Air-4 Bar & Vacuum) 81 3 - Gas (O2, Med Air-4 Bar & Vacuum) 82 2 - Gas (O2 & Vacuum) 83 SITC Of Area Valve Service Unit with Valve & Gauge 84 The importance of full bore ball valves is to reduce pressure drop to almost negligible in the pipeline distribution system so that the designed pressure is available at the outlet point. Ball Valves are used to start or stop a flow. In Medical Gas Pipeline System (MGPS), the valves are normally kept open i.e. allow the gas to flow unless it is required to shut-off the gas supply for scheduled maintenance or emergency situation 85 Features-Operational parameters can be set in-situDigital pressure unit display options -psi / bar or kg/cmDigital & illuminated LED display of “Normal”, “High” & “Low”Microprocessor based moduleHighly accurate “Heavy Duty” pressure transducerPowder coated aesthetically designed enclosureEnclosure separable from the base for ease of installationReusable lock assemblyAudio mute optionPED: 2014/68/EU certified full port Ball Valve (PN 30)Long extension copper pipes to connect MGPS networkFront door opens up vertically for comfortable accessDesigned to serve 2, 3, 4 & 5 gas moduleSuitable for all medical Gases & VacuumMake- Altos/Aktiv or Equivalent 86 6 Gas Service (O2, N2O, Med Air-4 Bar,Air-7 Bar, Vacuum & CO2) 87 5 Gas Service(O2, N2O, Med Air-4 Bar, Air-7 Bar & Vacuum) 88 4 Gas Service(O2, N2O, Med Air-4 Bar & Vacuum) 89 3 Gas Service (O2, Med Air-4 Bar & Vacuum) 90 2 Gas Service(O2 & Vacuum) 91 SITC of Degreased Medical Lockable Ball Valve with Pipe line assembly 92 Pre piped single port) for size upto 2 (for 54mm copper pipe): Pre Piped Degreased Ball Valve with pipe extension. It should be full-port design. It shouldbe blow-out proof stem. It should be lockable valve. The Valve shall be 3 piece ball-type design with a bronze body and chrome plated brass ball for sizes 1/2” to 4”. Seats shall be Teflon (TFE) and seals Viton for 1/2” - 4” valves. A blow-out proof stem shall be used and the valve shall have a maximum pressure rating of 600 psi [4,137 kPa].Valves shall be operated by a lever-type handle requiring only a quarter turn from a fully open position to a fully closed position. Valves shall be designed in such a manner that it can be “swung-out” during installation so as to prevent damage due to heat transfer during the brazing operation. Each valve assembly shall be washed and degreased for medical gas service. The valve shall be supplied in a sealed plastic bag to prevent contamination prior to installation.Make- Altos/Aktiv or Equivalent 93 12mm 94 15 mm 95 22 mm 96 28 mm 97 35mm 98 42 mm 99 54 mm 100 108mm 101 SITC of Bed Head Panel aluminum powder coated with mininum 3 channel and 3 duct with separate partition rows and built in aluminum railMake- Altos/Aktiv or Equivalent 102 Bedhead panel for Low Equity Ward Areas, 1500mm length, with provision of Gas outlets & provided with electrical sockets & accessories complete 103 Horizontal Bed Head Panel – For 2 Gas Service (Oxygen & Vacuum) 104 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, Med Air-4 Bar & Vacuum) 105 Horizontal Bed Head Panel – For 3 Gas Service (Oxygen, N2O & Vacuum) 106 Horizontal Bed Head Panel – For 4 Gas Service (Oxygen, N2O, Med Air-4 Bar & Vacuum) 107 Special FeaturesInnovative design – Efficient, simple & accessibleVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outlet 108 Application AreasInnovative design – Efficient, simple & accessiblityVersatility – Configurable & economic adaptation of various servicesAesthetics – High quality surface finish, epoxy coated to RAL 7035(Textured)Smooth profile – Minimize adherence of dust particlesExtruded aluminium frame – Rigidity & ease of interior accessability to serviceSeparate compartments - for LV, ELV and Piped GasNon-disruptive maintenance of BS Outlet - Shut down of line gas is avoidedOption of concealed gas connections and choice of outletAdult in-patient wards/ General WardsResuscitation RoomsPost-anaesthesia areaEmergency Admission WardsDialysis Stations 109 Configuration : 5 Outlets & 6 Multi Standard 220V AC sockets, 1 each RJ11 Telephone socket & RJ45 Data Socket and provision of protective earth (Earthing) 110 Modular Operation Theatre (Part-B) 111 WALL AND CEILING MODULAR PUF PANEL 112 The panels shall be made of durable and uniform material that shall be easy to clean and extremely hygienic. Operation theatre shall not have any sharp edges, corners and shall not support bacteriological or fungicidal growth and shall be resistant to most chemicals, commonly used in Hospital Departments. Joints in the panels in the operation theatre shall be sealed. The function of sealing shall assure an airtight environment in the room and eliminate services to prevent dust accumulation.PUF Panel with an overall thickness of 50 mm for wall and 30 mm for ceiling, made of 0.8mm (make-Tata/jindal)GI Front sheet and 0.6mm PPGI back wall with infill of PUF at 40 kg/m3 (40D)which is necessary for mechanical strength. Panels shall be mounted on a structure made of galvanized steel and shall enable the distribution of medical gases, electricity, sewerage inside the wall.PUF Panel as above has better thermal efficiency and thus saving on energy cost. Proposed system shall be installed at site without any welding.The partitions shall not have corners; adjacent surfaces shall be molded flush.Upper wall element shall have sufficient height to reach the lower edge of the prefabricated ceiling. All the sharp edges and corners should be chamfered to avoid bacterial contamination.The individual ceiling panels shall use the tongue and groove technology for joining two panels, no welding shall be allowed,provides a seamless sub-structure, which is then sanded smooth finished with Metal Putty and then painted using imported anti-fungal paint to give a smooth, non-porous seamless finish and without corners by providing coving on floor as per standard.It is resistant to chemicals used in Operation Room for moping and fumigation repeatedly.Make-Jindal/Tata or Equivalent 113 WALL AND CEILING MODULAR PUF PANEL-SS304 114 The prefabricated Operating Room should be of SS Sandwich as per its latest standards. SS Sandwich : It should have at least min. 0.8 mm 304 Grade Stainless Steel on front side and 0.5mm PPGI back side . The sandwich panel shall have a core consisting of rigid polyurethane foam, injected under high pressure, with a minimum density of 40 kg/m3. Cladding structure insulated stainless steel wall panels with total panel thickness 50 mm for wall and 30mm for ceiling.The individual wall panels shall use tha tongue and groove technology for joining two panels, no welding should be allowed. The gaps between panels shall be suitably filled with metal filler and sanded flush. Stainless steel plate finished to fine grain surface, treated properly to take antifungal paint panelingshould be easy to maintain, durable, antistatic / conductive and fire retardant. Clearance between inner panel and outer wall should be sufficient to allow the maintenance personnelfor service. This closed space should be flushed continuously to eliminate dust and bacterial accumulation.It should have minimum number of junctions. The junction should be seamless and should be sealed with suitable sealants. Third party test certificate for SS from material testing lab. (Govt. authorized)required.Make-Jindal/Tata or Equivalent 115 ANTI-FUNGAL PAINTING 116 Anti microbial Paint for Different Areas antibacterial Paint on wall and ceiling panels Inside OT work.Anti-Microbial Protection: These product hygiene coatings start the biocidal action as soon as the microorganism land on the surface, and prevents the growth of mould, bacteria and yeasts for at least 5 years.Minimum three coats of Anti Fungal/Bacterial Paint, glaze or equivalent to a minimum dry thickness of 300 microns to give smooth , non-porous finish without any corners.It will also be resistant to the chemicals used in Operation Room for Moping & Fumigation repeatedly. This Hygiene coating are independently tested by leading universities to demonstrate resistance.Make-SKK/ Jotun or Equivalent 117 PLENUM LAMINAR AIR-FLOW 118 Supply and installation of Plenum LAMINAR FLOW- Plenum Box Ceiling mounted systemwith unidirectional airflow, SPECIFICATIONS-PLENUM UNIT - The complete unit factory designed and manufactured with proper air-sealing. It seamlessly integrates with OT ceiling mounted equipment.Plenum size- 2400 x 2400mm with aluminium material.Diffusers are made of SS304 punched/perforated sheet for unidirectional diffusion air. The complete unit factory designed and manufactured with proper air-sealing.It seamlessly integrates with OT ceiling mounted equipment.The material used is non-corossive as per standard guidelines such as Aluminium.Make-Jindal/Tata or Equivalent 119 Hepa Filters- 120 The filter hosing on either side houses provided with HEPA minipleate H13/H14 filters.The system has a reliable filter efficiency, filters are designed to remove particles and germs with the use of H13/H14 filters retaining 99.97 % of the particles and germs.Frame : Aluminium Mini Pleat Size- 610x610x125mmMOC of the Media : Micro Fibre Glass micro drawn grid Separators : continuous Gasket: Food GradeMPPS average efficiency: > 99.95% 3 Micron D Efficiency: 99.97% down to 0.3µ.Maximum Operating Temp : 60 degree CelsiusMake- Thermadyne or Equivalent 121 ANTI-STATIC VINYL FLOORING: 122 SupplyandinstallationofImportedVinylFloor:SeamlessantistaticconductiveESDvinylflooringsystem,2mmthick, with perfectly curved flush covings and copper strips for earthing, all joints welded properly including wall scatting.SPECIFICATIONS:- Flooringinoperationtheaterroomwii beseamless withperfectly curvedflash-covings,resistance tomechanicalstressanddynamicloadsandhavingESD/EMI(Conductive)protectioncharacteristics,2mmthick, washablevinyl.Flooring is a static-conductive,flexible homogeneousvinyl floor covering withan electricalresistance of 5x10^4 123 SELF LEVELLING MATERIAL. 124 The SLC should be of Portland cement-based, It should be self-leveling underlayment formulated with a special blend of polymersusedtolevelandsmoothinteriorconcrete,terrazzo,ceramicandquarrytile,epoxycoatingsystems,metal andnon-watersolubleadhesiveresidueonconcretepriortotheinstallationoffinishedflooring–on,aboveorbelow grade.TheSLCshouldprovideadurable,flat,smoothfloor surfacewithminimumlabor andinstallationtime.Itshould be pourable or pump-able when mixed with water and should seek its own level to produce a smooth, flat, hard surface. 125 OPERATION THEATRE CONTROL PANEL: 126 Supply and installation of Membrane type 6 services OT control panel , with distribution box mounted flush in the theatre wall, comprising of the following:The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations.The room Surgeon’s control panel should be modifiable with changing technology& equipment in operating environments. Control Panel will be user friendly & ease of operating & maintaining purpose.he panel should be “Membrane” type; configured to incorporate all the services that operation room staff required. The fascia should be made with superior quality UV resistance membrane with sterilization feature.The Panel should contain 6 or 9 service tiles as below:1. Time Day Clock. 2. Time Elapse Day Clock. 3. General Lighting System.4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller.7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clocks having high brightness characters.Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digitaltype & clocks having high brightness characters, not less than 30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. system inside the theatre.The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures.A hand free set Telephone System should be incorporated in the panel with memory type card.The control panel should be designed for front- access only. All internal wires should beMake- Altos/DGline or Equivalent 127 Distribution Board outside OT 128 Electrical Distribution Board will have all high voltage equipment should be installed in a separate enclosure. The remote cabinet should house the operating transformers, light control relays, electrical distribution equipment and circuit protection equipment for all circuits withinthe operating theatre. All internal wiring should terminate in connectors with screw mounted, on a DIN rail. Individual miniature circuit breakers will protect all internal circuits. All high voltage equipment should be installed in a separate enclosure.All internal wiring should terminate in connectors with screw & clamp springConnections of the clip- on type mounted, on a CE/ / ICMED9001/ ICMED13485 approved rail & labeled with indelible proprietary labels.Individual fuses or miniature circuit breakers should protect all internal circuits. 129 LED PERIPHERAL/GENERAL LIGHTS: 130 Recess mounted sealed IP54 Protocol, non-hygroscopic peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED, with optical anti- glare system for individually adjustable light distribution.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated steel frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Control equipment for the general lighting and the light dimming should be provided in the theatre Control Panel.Make-Altos/DGline or Equivalent 131 LED X-RAY VIEW PANEL: 132 TwoPlateX-RayViewScreenwithflickerfreeilluminationhavingimportedLEDsystemforuniformilluminationand operated by X-ray film .Thesystemhavingelectricalsafetycodesforhigh&Lowvoltagesystem.Itshouldbedesignedtoprovideflickerfree luminance for the film viewing purpose.It should be installed flushed with the theatre wall for hygiene and ease of cleaning.Make-Altos/DGline or Equivalent 133 MAGNETIC LISTING WRITING BOARD: 134 MagneticWritingBoard of size940x 640x50mmcomprisesof aflushmounted,1.50mmthick,whitelaminate board, bonded toa 10 mm high density fibreboard sheet for additional rigidity.The writing unit should comprise of flush mounted white laminate board, be opened to create a wall mounted writing surface within the operating room. The white board should be constructed from white laminate board.Make- Altos/Dgline or Equivalent 135 AUTOMATIC HERMETICALLY SEALING SLIDING DOOR -1500mmX2100mm 136 Automaticoperated Hermettically Slidingdoor with High Pressure Laminate on both side, Door size (1500mm wide2100mmheight)completewithdoubletoughnedglassvisionwindowof300mmx300mm withinanaluminum extrusionhighqualityframecompletewithrequiredaccessories.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings that are adjustable during installation to ensure sealing.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door HandleMake-Metaflex/Doormedor Equivalent 137 HERMETICALLY SEALING HING DOOR-900mmX2100mm 138 Manually operated Hermettically Semi- sealed Hing door with HighPressure Laminateon bothside, Door size (900mm wide x 2100mm height) complete with double toughned glass vision window of300mm x300mm andsmooth effortless doorcompletewithrequiredaccessories,fixedfirmlytothewall.Thedoorframesconsistofreinforcedplasterboard panelsfacedwiththesamelaminateasthedoorandwillbeedgedwithanaluminiumextrusionandwithconcealed fixings.• Environment temperature should be -20°C to +55°C.The doorframe should be made of high quality anodize aluminum and the door panel should be made of compact laminate that can withstand high abrasion. To ensure efficient sealing of the doors frames should be provided. They will consist of reinforced plasterboard panels faced with the same laminate as the doorsVision panels, 300mm X 300 mm should be provided in the doors.The Door should be hinge mounted and should complete with all necessary accessories i.e.Door closer, D type SS Door Handle. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Nylon runner guides are fixed to the floor in such a way that they do not obstruct trolley movement through the door.Make-Metaflex/Doormed or Equivalent 139 CORNER GRILLS 140 Aluminium corner grills are used to air exhaust at all four corners.size of grill will be 600mmX400mm.Duly powder coated extruded aluminium linear horizontalfixed bar with normal 15 deg. blade having pitch of 13 mm.Exhaust Gril for return air-The exhaust air cabinets should be openable and cleanable. These cabinets should have suction from bottom.Distribution of exhaust air volume should be divided between fluff strainers to maintain the required pressure within the theatre without causing turbulence.The Exhaust air cabinet should be manufactured and supplied by the supplier of wall and ceiling system supplies. Also it should match perfectly with the ceiling system aesthetically.Make-conair/Bala ji engineering or Equivalent 141 ALUMINIUM DUCTING: 142 Aluminium Ducting ( 22 gauge ) with curves & bends where indicated for easy flow of air tight by applying silicon sealant after fabrication.Hangers will be provided to ducts & will be suspended be means of G.I. coated rod & these will not be more than 2.5 mtrs apart.Thermal insulation with 9/13mm XPE with aluminium foil for supply & return air ducts.Joints will be lapped with Nitrile tape for better insulation. (Laminar to AHU & Return air in all four corners) AHU to be placed near OT, not more than 6 meter.SITC OF Hand fabricated rectangular Aluminum Ducting in accordance with the approved ducting lay out drawing, complete with all accessories , dampers, guide, vanes, support, etc.Make-Hindalco/Virgo or Equivalent 143 AIR HANDLING UNIT 144 AHU System & Condensing Unit with consistingDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GI Frame Work Hollow Extruded AL Profile Thickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material ofDrain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base Channel DX COIL: Make Of Coil ZECO Coil Casing / Blank offs GI Material Of Tube Copper (IGT) Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material Copper Thickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12 FILTERS: Media of Filters Synthetic (non woven type) Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron FAN & MOTOR: Fan make Nicotra Motor make CG Motor type TEFC Squirrel Cage IP 55 Protected VFD Compatible induction motor VFD: VFD make DELTA DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE:(WITH 25MM THICK PANEL) ◻ Mixing box with manually operated FA & RA damper in GI constructionDOUBLE SKIN CASING: Outer Skin 0.6 mm Pre- Coated GI Inner Skin 0.6 mm Plain GIFrame Work Hollow Extruded AL ProfileThickness of Insulated Panels 25 mm thick, CFC Free PUF injected (Density: 40 kg / Cu. m.) Material of Drain Pan 20 G SS-304 Tray duly insulated with 13 mm closed cell Nitrile insulation. Unit Base G.S.S Base ChannelDX COIL: Dx type coils having suitable number of distributors for connecting expansion valve with condensing unitsMake-Zeco//VTS or Equivalent 145 Make Of Coil Casing / Blank offs GI Material Of Tube Copper (IGT)Tube Dia (mm / inch) 9.52 mm / 3/8” O.D. Thickness of tube (SWG / mm) 25 SWG / 0.5 mm Header Material CopperThickness & Material of fins 0.15 mm Plain Aluminum No. of Fins per inch (FPI) 11 / 12FILTERS: Media of Filters Synthetic (non woven type)Efficiency of Pre-filters (EU-4) 90 % down to 10 micron. Efficiency of Fine-filters (EU-5) 99 % down to 05 micron VFD: DOUBLE SKIN FLOOR MOUNTED HORIZONTAL AIR HANDLING UNIT SHALL HAVE: (WITH 25MM THICK PANEL)Mixing box with manually operated FA & RA damper in GI constructions.Filter section with 50 mm thick (EU-4) box type pre filter with 305 mm thick (EU-5) bag type fine filter mounted on common filter frameCoil section with 6 row deep DX cooling coil with suitable distributor. Heater Section with GI strip Heater.Fan section with SISWbackward curved plug fan & Motor (IE-2). Manually operated SA damper in GI construction.Tonnage TR 8.5 Air Qty (CFM) 3500SP (mm wg) 125 UnitFan Type Plug Fan-355Fan model RLC E6-3135-23-19 Fan RPM 3400Motor RPM 2880Shaft Absorbing Power 3.2 Motor Rating (kw) 3.7 Motor pole 2Coil area (Sq.Ft.) 7.0 DX Cooling Coil RD 6 Distributor 1Heater KW3Filter area (Sq.Ft.) 8.0 Length (mm) 2500Width (mm) 1400 Height (mm) 945 146 AIRCONDITIONING: (8.5 T AC ) 147 Nominal Cooling Capacity-8.5tr,102000Btu/hr,29894watt Nominal Air Quantity-6250CFMPower Supply (V-ph-Hz)-400 ± 10% -3-5 Fan-PropellerDischarge-HorizontalFan Motor-Permanent Split Capacitor Type Power (watt)-470Control Type-LED DisplayOverall dimensions (mm)-982 X 610 X 1100 mm- Compressor- Scroll CompressorRefrigerant-R-410A (5.6) Liquid Line-5/8Suction Line-1-1/8Make- Carrier or Equivalent 148 ELECTRICAL WIRING INSIDE THE OT 149 Electrical Wiring as per requirement of OT, Wiring With OT distribution electrical Panel. ( Power cable at OT with Main distribution Panel will be provided by customer) Operation theatre shall be installed in the remote cabinet.All electrical wiring should be terminated to the connectors mounted on DIN/CE approved rail and labeled with indelible labels.Individual fuse and miniature circuit breakers should protect all internal circuits.Complete schematic diagram drawing description should be enclosed with the equipment. Makes:Scheinder/PolyCab/ Schematic.Supply, Installation, Testing and Commisnoing of Electrical Distribution Board with required MCB : It should be installed in a separate enclosure.Transformers,Mains,Relays,Circuitprotectiveequipment,forallcircuitsofOperationtheatreshallbeinstalledinthe remote cabinet. 150 MEDICAL GAS PIPE-LINE SYSTEM INSIDE OT 151 Medical Gas Pipe Line inside the OT above ceiling as required, complete with valve box and other required fitings. Medical Gas copper pipeline inside the OT and the Provision to connect to Pendant Systems (inside OT only).It should be confirm and meets with BS:EN:13348:2008 copper pipes.All medical grade degreased copper pipes must be inspected and duly Third Party Certified by Lloyd’s Registered Asia. Medical Grade Copper pipes manufactured from Phosphorous de-oxidized non-arsenical copper to BS:EN: 1412:1996 grade CW024A (Cu-DHP) manufactured to metric outside diameters and having mechanical properties in accordance with BS:EN: 13348:2008 & 250 or 290 (Half hard).Degreasing of pipe shall be such that there is less than 20 mg/m2(0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified BS:EN:13348:2008.Make- Altos/Aktiv/Mandev tubes/Mehta tubes or Equivalent 152 PASS BOX SIZE-2FTX2FTX2FT 153 Pass Box to remove the waste materials from the Operation Room to the Dirty Linen Area. Each box is equipped with two doors and the door should be operated electronically.. It is designed in such a way that only one door can be opened at one time. UV light is so installed that it is kept on while both the doors are closed and turned off automatically when the doors are opened. Indicators on both side of the Operation Room for Door Open/Close status. It is made of SS-304 Grade.Make- Jindal/Tata or Equivalent 154 STORAGE UNIT 155 Storage Unit of size 850x1600x350 mm has made of 1.6mm galvanised steel sheet. The exterior glass doors has lockable with magnetic push-button for easy opening. Removable toughened glass shelves of thickness 5 mm will be provided with the storage units.Make- Jindal/Tata or Equivalent 156 Pressure Relief Dampers 157 Pressure relief dampers should be provided in each room to prevent contamination of air from clean and dirty areas. Suitably sized air pressure relief damper should be strategically placed, enabling differential room pressure to be maintained and ensure that when doors are opened between clean and dirty areasCounter- weight balancing system should be provided in the PRD to maintain positive pressure inside the operation room.Air pressure stabilizers should have unique capability of controlling differential pressure to close tolerance.The PRD should remain closed at pressure below the set pressure and should open fully at a pressure only fractionally above the threshold pressure.The body of PRD sleeve and Grill should be epoxy powder coated as per standard High grade SS304 Stainless steel plate should be used for body and for bladesMake- Jindal/Tata or Equivalent 158 OT Pendant –Single Arm Anesthesia(Modular) 159 Anesthesia Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.Make- Altos/Aktiv or Equivalent 160 The Pendant Service Heads / column should be supplied with medical gas terminal units. The medicalgas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard. 161 Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 2 no, Air (4 Bar) – 2 no, Vac – 2 nos, AGSS – 1 no. Medical rail with brake buttons fitted. - 1 No.Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its lengt 162 OT Pendant -SURGICAL PENDANT : 163 Surgon Pendent Systems should have the facility to provide convenient positioning of medical equipment.The support arms should be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.The Support arm should have atleast 10 mm thickness throughout to prevent any unnecessary deflection in Arms at given load.Arm Caps should be Aluminum Die casted Powder coated that allows its opening and closing a number of times as compared to ABS/Plastic end caps.High quality bearings shall be used to provide smooth and free movement, minimizing the force required to overcome static friction forces during repositioning. Bearings shall be permanently lubricated and sealed, withno maintenance or replacementPendant arms other than the cantilever lift arm shall be manufactured from extruded aluminium sections and available in various lengths. External surfaces of all arms shall be polyester powder coated in a RAL 9002/9003 finish. Tandem pendants for critical care areas shall be designed so that the consoles can readily swap sides within the bed bay to maximize the flexibility of the workspace.Non-return valves shall be fitted downstream of the connection to the medical / surgical air pipeline to prevent back-flow in the event of low distribution system pressure.Each arm should be capable of 330 – 340 degrees of rotation and be fitted with stops which can be easily adjusted to suit the desired mode of operation.Infinitely variable rotational stops should be available from 0-330 degree which shall enable precise of limits travel to be set to ensure maximum freedom of movement, whilst protecting walls and ancillary equipment.The rotational stops shall be dampened such that when limit of travel is reached, sensitive suspended equipment is not subjected to shock or vibration as the kinetic energy is absorbed.The arms may be fitted with pneumatic brakes or electromechanically breaks to prevent inadvertent movement.It should be possible to replace all medical gas hoses without the need for onsite crimping of ferrules. All medical gas hoses shall be colour coded to as per standard.The Pendant Service Heads / Column should be capable of accepting a range of shelves, drawers and infusion poles or other accessories. The Pendant Heads / column should support the range of Physiological Monitor Mounting Solutions. Service head should designed to host, Base, Gas Module, Electric Module and shelves.The Pendant Service Heads / column should be supplied with medical gas terminal units. The medical gas outlets fully comply with ISO 7396-1 and DIN 13260-2 standards. Medical gas hoses fully comply with thestandard BS EN 739 and are provided with NIST connectors to this standard.Each anaesthesia pendant should be Single arm having rotational movement with load carrying capacity of minimum 120 kg having following facilities:movable Arm with total coverage of minimum 1000 mm and 330 degree.The Pendant Service Head/column should be modular with minimum 1200 mm head. Gas outlets: O2 – 2 nos, N2O – 1 no, Air (4 Bar) – 1 no, Vac – 2 nos.Medical rail with brake buttons fitted. - 1 No.Make- Altos/Aktiv or Equivalent 164 Shelf with Drawer – 1 no. Infusion set – 1 no.Electrical Sockets – 10 nos. 6/16 Amp. 6 pin sockets. Pendants should comply with applicable standard:The terminal units must be according to ISO 7396-1 and DIN 13260-2 standards.Medical gas hoses shall be compliant to ISO 5359:2009 colour coded throughout its length. 165 UV LIGHT INSDIE OT FOR CLEAN/STERILIZE PERPOSE SIZE-2FTX1FT 166 Recess mounted sealed IP54 Protocol, non-hygroscopic UV peripheral lights ( 1 x 2 ) having compact high glow low wattage LED lighting system. These lights are having electrical safety code for high & low voltages.The luminaries for recess mounting in operation theatres should flush with the ceiling based on LED. Ultraviolet (UV) lamps are commonly used in operation theatres for disinfection.Luminaries cover made of highly-resistant, disinfectant-proof acrylic diffuser with white coated frame.Closing devices are integrated automatically in the electrical safety control without lines having to be connected to the luminaries housing. Luminaries’ body made of sheet steel, white, powder-coated, supplied ready for connection optionally for individual or group with power saving technology. Luminaries with protection IP 65, and protection class I,230 V,50 Hz.Recess frames for the gas-tight installation of clean-room luminaries in IP 65 in suspended ceilings.Frame made of extruded aluminium profile, white, powder-coated, able to be put together to form a rigid, continuous frame by means of plug and screw connections.Make- Altos/Dgline or Equivalent 167 Surgical Scrub Station – Two Bay 168 Compact surgical scrub sink should be designed for use in OT complex providing for pre – OT scrub up. Each fixture should be fabricated from heavy gauge type 304 stainless steel and should be seamless welded construction, polished to a satin finish.The washing faucet shall be made of Chrome plated brass hand. The station shall be equipped with soap dispensers made of SS 304 grade.The scrub sink should be provided with a front access panel which should be easily removed for access to the water controlled value, waste connections, stoppers and strainers.Hands free operation should include infra red sensors with built-in range of adjustment.The scrub station shall be made of high-grade stainless steel 304 with stain polish finish and wired to the current IEE regulations & BS 7971.Thermostatic mixing, valve control should be located behind the access panel and maintain constant water temperature. User defined setting of 1,3,6 & 10 min should be available. This timing should be adjustable to meet individual application requirements.All units should have reduced anti- splash fronts.The scrub stations control system shall be based on advanced microprocessorThe scrub station shall be sensor-activated 24VAC and should have the provision to operate it manually in case of power failure by using foot switch or knee switchimported thermostatic mixing valve for Hot & Cold water, Strainers, Spouts & manual foot operated valve system.Make- Jindal/Tata or Equivalent 169 AUTOMATIC PHASE SEQUENCE CONTROLLER 170 PMC Based (Pre magnetic Contractor)63A Double interlock & time Delay systemAuto/Manual Operation Sie- 140 x 275 x 320 mm Smooth and fasr Switchingworks well even at high & low voltages. Wide Current rnge.Voltage Range-130-280Vac Temperature- 55 Degree Celsius Auto mode Selector switchDigital micro Control relay for sequence management.LED Indicator for complete status of power.Make- Subtech or Equivalent 171 Operation Theatre Light - LED type, Camera Ready (Triple Arm) 172 Operating Room Surgical Lighting system should provde an ideal combination of broghtness, maneuverability, and shadow resolution without sacrificing color accuracy throuh a consistent LED technology. Such Lighting System should have the following technical specifications: 173 a. Number of light heads : Two per suspensionb. Colour Temperature range : 3800k-5000 (±10%) - Variable color temperature. c. Field Size Diameter : 20 to 28 cm (+/- 10%)d. Working range : 750 to 11100 mm (+/- 10 %)e. Illumination Level : 160000Lux (major Dome & Minor dome )f. Rotation : 360 - 330 degree g. Sterilizable Handle : 02 Nos h. Mounting type : Ceiling i. Supply Voltage : 230 VAC 50 Hz j. Bulb Type : LEDk. Dimming Range : 50% - 100%l. Operating / Storage Humidity : 10 - 95 %m. Life of Light source : > 40,000 Hrs n. Should be provision to mount the camera in 1 dome . o. Surgical Light System Should be compliant with relevant European CE / US FDA standardsMake- HillRom/Steris orEquivalent 174 GST Extra as applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
27.
Educational and Research Institute #9409761 Technical Bid
Supply Of Consumables/Non-Consumables Supply Of Consumables/Non-Consumables For The Department Of Urology , Additional Tender Conditions: 1. Firms Participating In The Tender Must Supply Or Demonstrate (In Case Of High Value Items) Samples Of The Items Quoted Within Two Weeks Of The Tender Opening Date 2.Quotation Will Not Be Accepted If Samples Are Not Submitted. 3. The Name And Address Of The Manufacturer Must Be Printed On The Packaging Of The Disposable Items Failing Which The Tender Is Liable To Be Rejected.4. The Products When Supplied To The Department Must Have A Minimum Period Of 24 Months Of Shelf Life From The Date Of Delivery. General Consumables , Ptfe Coated Stainless Steel Guide Wire Withstraight Flexibletip 0.021”150Cm(Presterilised & Disposable) , Ptfe Coated Stainless Steel Guide Wire Withstraightflexible 3Cm Tip 0.028” 150Cm(Presterilised & Disposable) , Ptfe Coated Stainless Steel Guide Wire Withstraight Flexible 3Cm Tip 0.035” 150Cm(Presterilised & Disposable) , Ptfe Coated Stainless Steel Guide Wire Withstraight Flexible 3Cm Tip 0.038” 150Cm(Presterilised & Disposable) , Ptfe Coatedheavy Duty Stainless Steel Guide Wire With J Tip 0.035”, 150Cm. (Presterilised & Disposable) , Ptfe Coated Heavy Duty Guide Wire With J Tip 0.038”, 80Cm (Presterilised & Disposable) , Hydrophilic Plastic Coated Stainless Steel Guide Wire (Like Terumo Radiofocus™Or Microvasive Glidewire ™Guide Wire) 0.018”, 150Cm With 3Cm. Flexible Straight Tip In Presterilised Pack (Disposable) , Hydrophilic Plastic Coated Stainless Steel Guide Wire (Like Terumo Radiofocus™Or Microvasive Glidewire ™Guide Wire) 0.025”, 150Cm With 3Cm. Flexible Straight Tip In Presterilised Pack (Disposable) , Hydrophilic Plastic Coated Stainless Steel Guide Wire (Like Terumo Radiofocus™Or Microvasive Glidewire ™Guide Wire) 0.032”, 150Cm With 3Cm. Flexible Straight Tip In Presterilised Pack (Disposable) , Hydrophilic Plastic Coated Stainless Steel Guide Wire (Like Terumo Radiofocus™Or Microvasive Glidewire™Guide Wire) 0.035”, 150Cm With 3Cm. Flexible Straight Tip In Presterilised Pack (Disposable) , Hydrophilic Plastic Coated Nitinol Guide Wire (Like Zebra™ Or Cobra™ Guide Wire) 0.025”, 150Cm With 3Cm. Flexible Straight Tip In Presterilised Pack (Disposable) , Hydrophilic Plastic Coated Nitinol Guide Wire (Like Zebra™ Or Cobra™ Guide Wire) 0.035”, 150Cm With 3Cm. Flexible Straight Tip In Presterilised Pack (Disposable) , Double Flexible-Tipped, Nitinol Core, Platinum Radio-Opaque Tipped, Hydrophilic Polymer Coated Lubricated Guide Wire Size 0.035 Inch Diam And 150Cm Length Such As Roadrunner® Pc Wire Guide Double Flexible In A Sterile Disposable Pack.(Bi-Wire) , Closed Ended Pvc Ureteric Catheter Soft With Stylet 70Cm 3F (Presterilised & Disposable) , Closed Ended Pvc Ureteric Catheter Soft With Stylet 70Cm 4F (Presterilised & Disposable) , Closed Ended Pvc Ureteric Catheter Soft With Stylet 70Cm 5F (Presterilised & Disposable) , Closed Ended Pvc Ureteric Catheter Soft With Stylet 70Cm 6F (Presterilised & Disposable) , Open End Radiopaque Pvc Tapered Tip Ureteric Catheter With Detachable Luer Lock, Connection 70Cm, 3F (Presterilised And Disposable) , Open End Radiopaque Pvc Tapered Tip Ureteric Catheter With Detachable Luer Lock, Connection 70Cm, 4F (Presterilised And Disposable) , Open End Radiopaque Pvc Tapered Tip Ureteric Catheter With Detachable Luer Lock, Connection 70Cm, 5F (Presterilised And Disposable) , Open End Radiopaque Pvc Tapered Tip Ureteric Catheter With Detachable Luer Lock, Connection 70Cm, 6F(Presterilised And Disposable) , Open End Radiopaque Pvc Tapered Tip Ureteric Catheter With Detachable Luer Lock, Connection 70Cm, 7F (Presterilised And Disposable) , Dual Lumen Ureteric Catheter With Flexible Tip Presterilised And Disposable With One Hole At The Tip To Accommodate 0.038 Inch Guide Wire And The Other Hole At The Side Near The Tip To Accommodate 0.038Inchguide Wire , 50Cm, 10F , Cone Tip Radiopaque Pvc Tapered Tip Ureteric Catheter With Detachable Luer Lock Connection 70Cm, 5F. Presterilised And Disposable , Double J Closed Ended Ureteral Stent Made Ofsoft Polyurethane With Positioner Size 3F, 14 Cm Presterilised And Disposable Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval. , Double J Closed Ended Ureteral Stent Made Ofsoft Polyurethane With Positioner Size 4F, 22 Cm Presterilised And Disposable Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval. , Double J Closed Ended Ureteral Stent Made Of Polyurethane With Positioner Size 5F, 22Cm Presterilised And Disposable Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval , Double J Closed Ended Ureteral Stent Made Of Polyurethane 5F ,16Cm. With Standard Positioner – Presterilised And Disposable Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval , Double J Closed Ended Ureteral Stent Made Of Polyurethane 5F, 26Cm. With Standard Positioner – Presterilised And Disposable Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval , Double J Closed Ended Ureteral Stent Made Of Polyurethane 6F 26Cm. With Positioner – Presterilised And Disposable Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval. , Double J Closed Ended Ureteral Stent Made Of Polyurethane With Positioner Size 5F, 16Cm Presterilised And Disposable Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval , 14 / 7 F Variable Double Pigtail Endopyelotomy Or Endoureterotomy Ureteral Stent 26 Cm. Made Of Polyurethane Presterilised And Disposable Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval. , Nitinol Ureteric Stone Basket With Polyamide Sheath That Resists Crumpling During Usage 3F 70 Cm Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval (Disposable And Presterilised). , Nitinol Tipless Stone Extractor Basket With Polyamide Sheath That Resists Crumpling During Usage, 2.2 Fr, 115 Cm Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval (Disposable And Presterilised) , Nitinol Tipless Stone Extractor Basket With Polyamide Sheath That Resists Crumpling During Usage, 1.5 Fr, 115 Cm Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval (Disposable And Presterilised) , Tipless Ureteroscopic Stone Basket For Stone Entrapment With The Basket Shaped In The Form Of A Pyramid In Open Position Similar To Ngage™ Of Size 2.2 Fr, 115 Cm , Ureteroscopic Three Prong Grasper Similar To Captura™ Capable Of Holding Stone And Foreign Body Of Size 2.8 Fr, 115 Cm , 3 Prong Cystoscopic Flexible Foreign Body Grasping Forceps 5.0F, 70 Cm (Disposable And Presterilised) , Pigtail Radiopaque Soft Polyurethane Nephrostomy Catheter 20Cm Long (Excluding The Length Of Coil) With A Straightener Canula 10F Disposable And Presterilised Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval , Pigtail Radiopaque Soft Polyurethane Nephrostomy Catheter 20Cm Long (Excluding The Length Of Coil) With A Straightener Canula 12F Disposable And Presterilised Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval , Pigtail Radiopaque Soft Polyurethane Nephrostomy Catheter 20Cm Long (Excluding The Length Of Coil) With A Straightener Canula 14F Disposable And Presterilised Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval , Pigtail Radiopaque Soft Polyurethane Nephrostomy Catheter 20Cm Long (Excluding The Length Of Coil) With A Straightener Canula 16F Disposable And Presterilised Carrying An International Authentication Of Quality Like Ce, Bis Or Fda Approval , Percutaneous Pigtail Nephrostomy Set In Presterilised And Disposable Single Pack. Each Pack Containing The Following: Specifications: Each Pack Containing: I) 18G 20Cm 2 Part Puncture Needle Ii) 0.038” 3Mm J Tip Ptfe Coated Guide Wire 80Cm Long Iii) Set Of Radiopaque Pvc Dilators 9-12F Iv) 10F Pigtail Nephrostomy Catheter Of Soft Polyurethane 20Cm Long (Excluding The Length Of Coil) Along With A Straightener Canula. V) Connecting Tube With Stopcock For Connecting To A Urine Collecting Bag Vi) Must Carry Any International Authentication Of Quality Like Ce, Bis Or Fda Approval , Malecot Type Nephrostomy Tube, Radiopaque, Made Of Polyurethane, With Straightener And Connector For Urobag, 20 Cm Long, 10F (In A Sterile Pack) , Malecot Type Nephrostomy Tube, Radiopaque, Made Of Polyurethane, With Straightener And Connector For Urobag, 20 Cm Long, 12F (In A Sterile Pack) , Malecot Type Nephrostomy Tube, Radiopaque, Made Of Polyurethane, With Straightener And Connector For Urobag, 20 Cm Long, 14F (In A Sterile Pack) , Chiba (Skinny) Needle With Stylet 24G 20Cm (For Puncturing And Opacifying Renal Pelvis)-Presterilised And Disposable , Sterile And Disposable Two Part Trocar Needle With Echo Tip 18G, 20Cm For Initial Puncture In Percutaneous Nephrostomy. , Sterile And Disposable Two Part Trocar Needle With Echo Tip 18G, 15Cm For Initial Puncture In Percutaneous Nephrostomy. , Set Of Fascial Dilators Of Radiopaque Polyethylene For Percutaneous Nephrostomy (Each Set Consisting Dilators 8F To 14F Size) Presterilised And Disposable , Amplatz Type Graduated Renal Dilator Set (Presterilised And Disposable) With The Following: Specifications Each Set Must Have: I) 8F-30F Radiopaque Pvc Dilators Set With Smooth Surface And Short Tapered Tips Ii) 8F Radiopaque Stylet With Both Ends Tapered For Minimising Kinking Of Guide Wire Iii) Sheath For Above Stylet For Insertion Of Safety Guide Wire Iv) Radiopaque Amplatz Type Teflon Renal Sheath Set With 3 Sheaths Of Sizes 28F, 30F And 32F -17Cm Long , Pcnl Access Sheath With Separate Suction Channel (14/16Fr X 17Cm) , Pcnl Access Sheath With Separate Suction Channel ( 18/20Fr X 17Cm) , Pcnl Access Sheath With Separate Suction Channel ( 22/24Fr X 17Cm) , Kaye Nephrostomy Tamponade Balloon Catheter Made Of Radiopaque Polyethylene, Size 17 F And Length 25 Cm, With 15 Cm Long 12 Mm Inflated Diameter Balloon, With A Flexible Stylet Along With A Polyurethane Stent Of Size 5F, 75 Cm Long All In A Sterile Pack. , Ureteral Balloon Dilator Catheter With 5Mm Balloon 4Cm Long (40 Psi Pressure) 5.0F 65Cm Long; Presterilised And Disposable , Ureteral Balloon Dilator Catheter 3.0F 65Cm Long, With 5Mm Balloon 4Cm Long (225 Psi Max Inflation Pressure) Presterilised And Disposable , Ureteral Balloon Dilatation Tipless Catheter, 6F, 65 Cm,4 Cm Long Balloon, 6Mm Inflated Balloon Diameter,60 Psi Pressure, Presterilised & Disposable , Ureteral Access Sheath10f 45 Cm With Matching Ptfe Dilator That Fits Inside The Sheath To Facilitate Its Insertion Over A Guide Wiree.G. Flexor (Cook Urological), The Access Forté Xe (Applied Medical), The Navigator (Boston Scientific), And The Aquaguide (Bard Urological). , Ureteral Access Sheath12f 45Cm With Matching Ptfe Dilator That Fits Inside The Sheath To Facilitate Its Insertion Over A Guide Wiree.G. Flexor (Cook Urological), The Access Forté Xe (Applied Medical), The Navigator (Boston Scientific), And The Aquaguide (Bard Urological). , Ureteral Access Sheath10f45cm With Matching Ptfe Dilator That Fits Inside The Sheath To Facilitate Its Insertion Over A Guide Wire. (This Should Be Flexible, And Navigable With Suction , Ureteral Dilator Set With Each Dilator Made Of Polyethylene With Hydrophilic Coating Capable Of Being Used With A Guidewire With Sizes 6, 8, 9, 10, 11, 12, 14, 16, 18 Fr And Length 60 Cm- 1 Set , Sterile And Disposable Irrigation Device With Compressible Bulb For Irrigation During Ureteroscopy Like “Path Finder™” , Plastic Toomey Syringe (70Ml) With A Ring At The End Of Piston To Permit Single-Handed Operation & To Fit Karl Storz Sheath, Presterilised And Disposable. , Plastic Tur Chips Evacuator To Fit Karl Storz Sheath, Presterilised And Disposable. , Tur Irrigation Set With Yconnection Of Total Length Of 300Cm (Long) – Presterilised And Disposable , Long Wearing Self Adhesive Skin Barrier With Flange (Of A 2 Piece Urostomy Appliance) Size 38Mm (Convatec / Coloplast/ Hollister Type) With Suitable Pouch With Connector For Each Bag , Long Wearing Self Adhesive Skin Barrier With Flange (Of A 2 Piece Urostomy Appliance) Size 45Mm (Convatec / Coloplast/ Hollister Type) With Suitable Pouch With Connector For Each Bag , Long Wearing Self Adhesive Skin Barrier With Flange (Of A 2 Piece Urostomy Appliance) Size 45Mm (Convatec / Coloplast/ Hollister Type) With Suitable Pouch With Connector For Each Bag. Should Be Convex Type For Flush Stoma. , Long Wearing Self Adhesive Skin Barrier With Flange (Of A 2 Piece Urostomy Appliance) Size 57Mm (Convatec / Coloplast/ Hollister Type) With Suitable Pouch With Connector For Each Bag , 3-Way Silicone Coated Latex Foley Catheter Of International Standards From Reputed Manufacturers (Whose Name Must Be Printed On Package And Catheter And Manufacturers Complete Address Must Be Printed On The Packaging) Pre-Sterilized By Gamma Irradiation Or Ethylene Oxide, Size: 20F , Disposable Sterile Suprapubic Puncture And Drainage Set (10F) , Disposable Presterilised Turp Drape .The Drape Should Fit Ove Thte Allen Stirrups And Should Drain To Bucket And Protect Surgons Leg , Disposable Presterilised Pcnl Drape And Should Drain To Bucket And Protect Surgons Leg , Drape Laparotomy,Sterile, Disposable - Consists Of Re-Inforced Mayo Stand Cover 120Cm/140Cm, Utility Drape Four Pieces 75/50 Cm, Transverse Drape 200/150 Cm,Head End Curtain 200/150 Cm, Hole Sheet 300/150 Cm. , Disposable Presterilised Plastic Cover For Laparoscopic Camera Cable , Sterile Skin Adherent Film Like Steridrape™ Or Opsite™ Size 30X30cm , Disposable Single Use Bulldog Clamp , Light Weight, Maxi Size 45 Deg Angle, (2 Per Pack) ( 5 Pack In A Box) Like Maxi Angled Scanlanvascu-Statt Ii ) , Disposable Single Use Bulldog Clamp , Light Weight, Maxi Size Straight, (2 Per Pack) ( 5 Pack In A Box) Like Maxi Straight Scanlanvascu-Statt Ii ) , Catheter Forgarty, 3Fr , Catheter Forgarty, 5Fr , Suture Capturing Device Like Capioslim Of Boston Surgical With Shaft Dia 3Mm, Head Widht 6.3Mm, Carrier Dia 1.2Mm , 6-0 Prolene Blue 13Mmx75cm C-1 Double Armed Visi-Black (32/Pack) , 180 Days Absorbable Polyglyconate Knotless Wound Closure Device With Unidirectional & Dual Angled Cut Barbs Geometry **3-0 15Cm, Green17mm1/2 Circle Taper Point. , 180 Days Absorbable Polyglyconate Knotless Wound Closure Device With Unidirectional & Dual Angled Cut Barbs Geometry 3-0 26Mm 15Cm 1/2 Circle Taper Point. , 180 Days Absorbable Polyglyconate Knotless Wound Closure Device With Unidirectional & Dual Angled Cut Barbs Geometry3-0 26Mm 30Cm 1/2 Circle Taper Point. , 180 Days Absorbable Polyglyconate Knotless Wound Closure Device With Unidirectional & Dual Angled Cut Barbs Geometry2-0 26Mm 15Cm 1/2 Circle Taper Point. , 180 Days Absorbable Polyglyconate Knotless Wound Closure Device With Unidirectional & Dual Angled Cut Barbs Geometry **2-0 15Cm, Green37mm1/2 Circle Taper Point. , 180 Days Absorbable Polyglyconate Knotless Wound Closure Device With Unidirectional & Dual Angled Cut Barbs Geometry 2-0 26Mm 30Cm 1/2 Circle Taper Point , Sterile Disposable Silicone Vascular Sling- Red Colour , Sterile Disposable Silicone Vascular Sling- Blue Colour , Sterile Disposable Silicone Vascular Sling- Yellow Colour , Sterile Disposable Silicone Vascular Sling- White Colour , Sterile Disposable Vascular Punch 2.5Mm Diameter , Sterile Disposable Vascular Punch 2.8Mm Diameter , Sterile Disposable Vascular Punch 3Mm Diameter , Sterile Disposable Vascular Punch 3.5Mm Diameter , Trans Obturator Mid Urethral Sling Complete Kit For Female Urethral Incontinence Approved By An International Agency Such As Fda Or Dcgi Or Ce Or Bis , Trans Obturator Or Retropubic Mid Urethral Sling For Female Urethral Incontinence Approved By An International Agency Such As Fda Or Dcgi Or Ce Or Bis , Transobturator Mid Urethral Sling By Outside In Technique, Complete Kit For Female Urethral Incontinence Approved By An International Agency Such As Fda Or Dcgi Or Ce Or Bis , Transobturator Urethral Sling System For Male Stress Incontinence By Outside In Technique, Complete Kit Approved By An International Agency Such As Fda Or Dcgi Or Ce Or Bis , Retropubic Mid Urethral Sling Complete Kit For Female Urethral Incontinence Approved By An International Agency Such As Fda Or Dcgi Or Ce Or Bis , Implantable Malleable Penile Prosthesis Set - Size 9 , Implantable Inflatable Penile Prosthesis Set - Size 11 , Implantable Inflatable Penile Prosthesis Set - Size 12 , Implantable Testicular Prosthesis , Implantable 2 Or 3 Piece Artificial Urinary Sphincter Set , Sterile Disposable Surgical Mopping Pad With Radio-Opaque Line Marker & Acoloured Loop 30 X 30 Cm. (12 Ply) Specification: The Marker Should Be Made Up Of Multifilament Yarn With At Least 60% Barium Coated Which Will Not Break Or Comeout Separately During Usage.Each Should Have Folded And Stitched Edges To Avoid Fraying Of The Fabric. The Material Should Have Been Bleached Using Hydrogen Peroxide. Each Pack Should Have Eto Sterilizedwith Double Sealed Blister Packfor Secured Sterility With Sterility Indicator.There Should Be A Colored Loop For Identification. Mention The Number Of Pads In A Single Pack If The Cost Is Quoted For A Pack. Spr. , Unsterile Clean Autoclavable Disposable Surgical Mopping Pad With Radio-Opaque Line Marker & Acoloured Loop 30 X 30 Cm. (12 Ply) Specification: The Marker Should Be Made Up Of Multifilament Yarn With At Least 60% Barium Coated Which Will Not Break Or Comeout Separately During Usage.Each Should Have Folded And Stitched Edges To Avoid Fraying Of The Fabric. The Material Should Have Been Bleached Using Hydrogen Peroxide. There Should Be A Colored Loop For Identification. Mention The Number Of Pads In A Single Pack If The Cost Is Quoted For A Pack. , 0.9% Sterile Physiological Saline For Intravenous Use In 3 Litre Plastic Bottle Or Bag , Disposable Laparoscopic Cautery Hook With Hand Control Function The Lenth Of The Cautery Tip Should Be 38Cm. , Sterile Vaginal Probe Cover Made From Pure Natural Latex , Injection Onabotutinumtoxin A 100Unit , Injection Onabotutinumtoxin A 50Unit , Disposable Cystoscopicinjection Needle 37 Cm, 4F For Use Through A Storz Cystoscope Sheath Working Channel , Strile And Disposable Female Intermittent Catheter 6.5 Or 7 Long , Latex Free , Color - Coded Funnel For Easy French Size Indication , Recessed , Polished Eyelets, , C-Arm Drape Compatible For Siemens C-Arm Model: Mm5c (Sterile And Disposable) , Disposable Flexible Adult Size Neutral Plate (Twin Pin) With Suitable Cable To Fit With Covidien Diathermy , Disposable Flexible Adult Size Neutral Plate ( Single Pin) With Suitable Cable To Fit With Kls Martin , Presterilised Disposable Monopolar Diathermy Hand Piece With Cable To Fit L&T Diathermy D-400 , Stockings Upper Thigh Length, Graduated Compressionsizes -Large , Stockings Upper Thigh Length, Graduated Compressionsizes - Medium , Stockings Upper Thigh Length, Graduated Compressionsizes - Small , Stockings Upper Thigh Length, Graduated Compressionsizes - Xl , Steri Drape Isolation Bag 50Cmx50cm For Organ Preservation , Pessary Fitting Kit Made Of Silicon , High Quality And Skin Frindly Material , Ring Folding Pessary (Silicone) , Milex Ring With Knobmade Of Silicon , Absorbable Wound Closure Device 4-0 45 Cm , Operative Laparoscopy Consumables , Laparoscopic Titanium Clips Size-Large For Use With Ethicon Clip Applicator (In Sterile Cartridges Containing 6 Clips Each) , Laparoscopic Titanium Clips Size-Medium - Large For Use With Ethicon Clip Applicator (In Sterile Cartridges Containing 6 Clips Each) , Laparoscopic Titanium Clips Size-Medium For Use With Ethicon Clip Applicator (In Sterile Cartridges Containing 6 Clips Each) , Laparoscopic Titanium Clips Size-Small For Use With Ethicon Clip Applicator (In Sterile Cartridges Containing 6 Clips Each) , Laparoscopic Sterile & Disposable Monopolar L Hook Electrodes 5Mm , Laparoscopic Sterile & Disposable Suction Irrigation Cannula With Trumpet Valves 5Mm , Disposable Clip Applier Smallwith20 Preloaded Clips For Open Surgery , Disposable Clip Applier Medium With20 Preloaded Clips For Open Surgery , Disposable Clip Applier Large With20 Preloaded Clips For Open Surgery , Laparoscopic Sterile Disposable 10Mm Specimen Retrieval Bag, Deployable From Outside The Body With 4X6 Inch Bag Size , Specimen Retrieval Pouch Bag, Sterile And Disposable, Laparoscopic Impervious, Sizes-15Mm, 5Inchx9inch , Laparoscopic Sterile Disposable 10Mm Specimen Retrieval Bag With 600Ml , Laparoscopic Sterile & Disposable 5Mm Threaded Cannula With Bladeless Trocar , Laparoscopic Sterile & Disposable 10Mm Threaded Cannula With Bladeless Trocar , Laparoscopic Sterile & Disposable 12Mm Threaded Cannula With Bladeless Trocar , Laparoscopic Sterile & Disposable 5Mm Smooth Cannula With Bladeless Optical Trocar , Laparoscopic Sterile & Disposable 10Mm Smooth Cannula With Bladeless Optical Trocar , Laparoscopic Sterile & Disposable 12Mm Smooth Cannula With Bladeless Optical Trocar , Balloon Tipped Cannula 5Mm Smoothwith Bladeless Optical Trocar, Sterile & Disposable For Laparoscopy , Balloon Tipped Cannula 12 Mm Smoothwith Bladeless Optical Trocar, Sterile & Disposable For Laparoscopy , Cannula 12 Mm, Long 15Cm For Baiatric Surgery Smoothwith Bladeless Optical Trocar, Sterile & Disposable For Laparoscopy , Sterile Laparoscopic Endogia Universal Stapler , Reload For Sterile Laparoscopic Endogia Universal Stapler- White-Vascular - 30Mmwith Articulating Shaft With Articulating Shaft Compatible With Power And Mannual Stapler , Reload For Sterile Laparoscopic Endogia Universal Stapler- White-Vascular - 45Mmwith Articulating Shaft With Articulating Shaft Compatible With Power And Mannual Stapler , Reload For Sterile Laparoscopic Endogia Universal Stapler- Blue-- 60Mmwith Articulating Shaft Compatible With Power And Mannual Stapler , Reload For Sterile Laparoscopic Endogia Universal Stapler- White-- 60Mmwith Articulating Shaft With Articulating Shaft Compatible With Power And Mannual Stapler , Endocutter 35Mm With Articulatingshaft, Length 34 Cm , Reload 35Mm White (Articulating) (1Mm)Compatible With Above Lap Linear Cutter Stapler With Articulating Shaft Compatible With Power And Mannual Stapler , Endocutter 45Mm With Articulatingshaft, Length 34 Cm , Reload 45Mm (Articulating) White (1Mm)Compatible With Above Lap Linear Cutter Stapler With Articulating Shaft Compatible With Power And Mannual Stapler , Endocutter 60Mm With Articulating Shaft, Length 34Cm , Reload 60Mm (Articulating) White(1Mm)Compatible With Above Lap Linear Cutter Stapler With Articulating Shaft Compatible With Power And Mannual Stapler , Reload 60Mm (Articulating) Blue(1.5Mm) Compatible With Above Lap Linear Cutter Stapler With Articulating Shaft Compatible With Power And Mannual Stapler , Multifire Endo Ta 30-2.5Mm 12Mmsingle Use Staplers , Multifire Endo Ta 30-2.5Mm 12Mmsingle Use Loading Unit , Tyvek Roll 500Mm X 70M , Lithoclast Probe 0.8Mm X 605Mm For Uretroscopic Lithotripsy Compatible For Ems Lithoclast , Lithoclast Probe 1Mm X 605Mm For Uretroscopic Lithotripsy Compatible For Ems Lithoclast , Lithoclast Probe 0.8Mm For Mininephroscopic Lithotripsy Compatible For Ems Lithoclast , Flexible Single Use Cystoscope , Flexible Single Use Rirs , Htk Solution For Renal Transplant (500Ml/Pack) , Endo Gia Tri- Staple 2.0 Intelligent Reload 45Mm Purple Medium/Thickwith Tri- Staple Technology Having A Height Of 3.0Mm, 3.5Mm And 4.0Mm - Capabable Of Placing In Mannual And Power Stapler (6/Box) , Endo Gia Tri- Staple 2.0 Intelligent Reload 60Mm Purple Medium/Thickwith Tri- Staple Technology Having A Height Of 3.0Mm, 3.5Mm And 4.0Mm- Capabable Of Placing In Mannual And Power Stapler(6/Box) , Endo Gia Tri- Staple 2.0 Intelligent Reload 45Mm Tan Vascular/Medium With Tri- Staple Technology Having A Height Of 2.0Mm, 2.5Mm And 3.0Mm- Capabable Of Placing In Mannual And Power Stapler (6/Box) , Endo Gia Tri- Staple 2.0 Intelligent Reload 60Mm Tan Vascular/Medium With Tri- Staple Technology Having A Height Of 2.0Mm, 2.5Mm And 3.0Mm- Capabable Of Placing In Mannual And Power Stapler(6/Box) , Endo Gia Tri- Staple 2.0 Intelligent 45Mm Loading Unit For Tan And Purple Tri- Staple Reloads (6/Box) , Endo Gia Tri- Staple 2.0 Intelligent 60Mm Loading Unit For Tan And Purple Tri- Staple Reloads (6/Box) , Equipment Consumables , Angled Cutting Loop (Monopolar) 24/26 Fr , Color Code : Yellow (Single Stem) - For Turp Compatible With Karl Storz Resectoscope (Per Pack 6 Pcs) , Straight Urethrotomy Knife -(Viu Knife) Compatibale With Karlstroz Working Element 27050Ek(Per Pack 6 Pcs) , Roller Electrode (Monopolar) Compatibale Withkarl Storz Resectoscope(Per Pack 6 Pcs) , Straight Collins Knife For Incision Compatible With Karl Storz Resectoscope Size 24F(Per Pack 6 Pcs) , Otis Urethrotome Knife Compatibale With Karlstroz Otis Urethrotome , Otis Urethrotome Knife Compatibale With Wolf Otis Urethrotome , Bipolar Coagulation Electrode-For Turp Compatible With Karl Storz Bipolar Working Element , Bipolar Cutting Loop -For Turp Compatible With Karl Storz Bipolar Working Element , Bipolar Knife Electrode -For Turp Compatible With Karl Storz Bipolar Working Element , Compression Sleeve Medium Knee Length Compatiable With Scd Express , Compression Sleeve Large Knee Length Compatiable With Scd Express , Compression Sleeve Medium Thigh Length Compatiable With Scd Express , Compression Sleeve Large Thigh Length Compatiable With Scd Express , Kick Resistance Compressionsystem Tubing Kit (Complete Set)Compatiable With Scd Express , Sterile Disposable Upper Body For Adult Compatible With Bair Hugger Patient Warmer Model : 775 , Sterile Disposable Lower Body Blanket For Adult Compatible With Bair Hugger Patient Warmer Model : 775 , Sterile Disposable Full Body Blanket For Adult For Use In Post Operative Icu Compatible With Bair Hugger Patient Warmer Model : 775 , Nibp Cuff Adult Size Compatible With L&T Starplus Multiparameter Monitor (S-20, M-80, L-20) , Nibp Cuff Adult Size Compatible With Wipro Ge Monitormodel : B450 (S-20, M-80, L-20) , Nibp Hose Assembly Compatible With Wipro Ge Monitormodel : B450 , D Type Spo2 Extension Cable Compatible With L&T Starplus Multiparameter Monitor , Spo2 Probe Adult Size Like Duro ™ Sensor Compatible With Wipro Ge Monitormodel : B450 , Spo2 Probe Adult Size Like Duro ™ Sensor Compatible With L&T Starplus Multiparameter Monitor , Disposable Presterilised Pressure Transducer To Fit Albyn Urodynamic System , Disposable Presterilised Pressure Dome To Fit In Pressure Transducer Of Albyn Urodynamic System , Double Lumen Rectal Balloon Catheter Compatible For Albyn Urodynamic System. , Twin Lumen Catheter For Recording Bladder Pressures (8F) Compatible For Albyn Urodynamic System. , Measuring Tubes For Albyn System , Infusion Pump Tubings For Albyn System , Ventilator Circuit Sterile And Disposable Compatible For Servos Ventilators Of Maquet Make , Catheter Mount For Ventilator , Grey Handpeice Compatible With Harmonic Laparoscopic Shears , Blue Handpeice Compatible With Harmonic Laparoscopic Shears , Ultrasonic 5Mm, Open Curved Shear, Shaft Length 23Cm, Compatible With Harmonic Gen11 , Ultrasonic Curved Shear For Open Surgery, 17Cm, Compatible With Harmonic Gen 11 , Enseal Articulating Tissue Sealer 5Mm 36Cm , Disposable Bipolar Cord Compatible With Force Triad/Ft 10 (Covidian) , Bipolar Cable Compatible With Wolf Bipolar Resectoscope Set , Bipolar Resection Cord 15 Compatible With Karlstorz Bipolar Working Element , Disposable Bipolar Cord Compatible With Force Triad/Ft 10 (Covidian) , Coagulation Electrodes Compatiable With Wolf Bipolar Resectoscope , Hookelectrodes Compatiable With Wolf Bipolar Resectoscope , Disposableligasure Blunt Tip 5 Mm Laparoscopic Sealer/Divider 37Cm Compatible With Electrosurgical Energy System Model: Force Triad Energy Platform Make: Covidien , Disposable Ligasure Maryland Laparoscopic Sealer Divider One Step Action 37Cm Length, 5Mm Dia , Disposable Ligasure Maryland Laparoscopic Sealer Divider One Step Action 23Cm Length, 5Mm Dia , Vessel Sealing Instrument With 36Mm Jaw Length And 34Mm Cut Length Curvedjaw 18Cm Shaftwith Electrosurgical Energy System Model: Force Triad Energy Platform Make: Covidien ( Ligasureimpact) , Vessel Sealing Instrument With 22Mm Jaw Length And 20Mm Cut Length Straightjaw 37Cm Shaft Length With 10Mm Shaft Dia Compatibale Withelectrosurgical Energy System Model: Force Triad Energy Platform Make: Covidien (Atlas) , Sterile And Disposable Endoscopic Surgery Instrument - 5Mm 35Cm Type S Front Actuated Grip Compatiable For Thunderbeat (Per Box - 5 Pcs) , Sterile And Disposable Endoscopic Surgery Instrument - 5Mm 45Cm Type S Front Actuated Grip Compatiable For Thunderbeat , Strile And Disposable Open Surgery Instrument - 5Mm 20Cm Ty(Per Box - 5 Pcs)Pe S Front Actuated Grip Compatiable For Thunderbeat (Per Box - 5 Pcs) , Strile And Disposable Open Surgery Instrument - 9Mm 20Cm Open Extended Jaw Front Actuated Grip Compatiable For Thunderbeat (Per Box - 5 Pcs) , Strile And Disposable Open Surgery Instrument - 5Mm 10Cm Inline Grip Compatiable For Thunderbeat , Strile And Disposable Open Surgery Instrument -9Cm Scissors With Open Fine Jaw Compatiable For Thunderbeat , Plasma Kinetic Cutting Small Electrode For Bipolar Resection In Saline It Should Compatible With 12Deg Telescope(Per Box - 12 Pcs) , Plasma Kinetic Cutting Medium Electrode For Bipolar Resection In Saline It Should Compatible With 12Deg Telescope ( (Per Box - 12 Pcs) , Plasma Kinetic Needle Electrode For Bipolar Baldder Neck Incision , Plasma Kinetic Button Electrode For Bipolar Baldder Neck Incision , Plasma Kinetic Roller Electrode For Bipolar Baldder Neck Incision , Plasma Kinetic Vaparoization Electrode For Bipolar Resection In Saline , Angled Loop For Eneculation Of Prostate For Bipolar Resection In Saline (Per Box 12 Pcs) , Bipolar Resection Cable For Plasma Kinetic Electrodes , Bipolar Cable Compatible With Olympus Esg -400 Electrosurgical Unit , 1.9 Fr X 90 Cm Nitinol Stone Retrieval Basket With Two Port Scope Adaptor To Be Used In Combination With A 200? Laser Fiber In Most Semi-Rigid And Flexible Ureteroscopes And Maintain Cage Stability During Deployment. Should Have 4 Wire Cage Design With 11 Mm Cage Diameter And 15 Mm Diameter When Extended Fully Similar To Escape®. , 1.9 Fr X 120 Cm Nitinol Stone Retrieval Basket With Two Port Scope Adaptor To Be Used In Combination With A 200? Laser Fiber In Most Semi-Rigid And Flexible Ureteroscopes And Maintain Cage Stability During Deployment. Should Have 4 Wire Cage Design With 11 Mm Cage Diameter And 15 Mm Diameter When Extended Fully Similar To Escape®. , Cystoscopic Stent Removal Rigid Triprong Forceps 3Fr , 11/13 Fr X 36 Cm Flexible Ureteral Access Sheath Should Have Kink Resistant Sheath Reinforcement For Stability, Tapered Tip And Radiopaque Marker For Precise Placement. Should Have Hydrophilic Coating On Sheath As Well As Dilator For Ease Of Insertion.Should Have Dual Durometer For Atraumatic Entry And Single Latch Mechanism For Ease Of Use Similar To Navigator Hd®. , 12/14 Fr X 36 Cm Flexible Ureteral Access Sheath Should Have Kink Resistant Sheath Reinforcement For Stability, Tapered Tip And Radiopaque Marker For Precise Placement. Should Have Hydrophilic Coating On Sheath As Well As Dilator For Ease Of Insertion.Should Have Dual Durometer For Atraumatic Entry And Single Latch Mechanism For Ease Of Use Similar To Navigator Hd®. , Nephrostomy High Pressure Balloon Catheter For Radial Dilatation Of The Nephrostomy Tract For Working Sheath Placement. Should Have A Radiopaque Marker. Should Be Supplied With A Compatible Ptfe Sheath And Inflator With Pressure Gauge. Should Supply 30 Fr X 12 Cm Size Balloon With 17 Cm Ptfe Sheath. , Nephrostomy Balloon High Pressure Catheter For Radial Dilatation Of The Nephrostomy Tract For Working Sheath Placement. Should Have A Radiopaque Marker. Should Be Supplied With A Compatible Ptfe Sheath And Inflator With Pressure Gauge. Should Supply 30 Fr X 15 Cm Size Balloon With 20 Cm Ptfe Sheath. , Stone Retrieval Basket Made Up Of Polyimide With Flatwire Construction Design To Maintain Basket Symmetry When Stone Is Captured. Should Supply 2.4 Fr X 90 Cm With Basket Od Of 16 Mm Similar To Segura®. , Stone Retrieval Basket Made Up Of Polyimide With Flatwire Construction Design To Maintain Basket Symmetry When Stone Is Captured. Should Supply 3 Fr X 120 Cm With Basket Od Of 16 Mm Similar To Segura®. , 1.9 Frx8mmx120cm Nitinol Stone Retrievaldevice With Opensure Handle, Have Three Arm Stone Retrievalbasket Opens And Closes At Full Deflection To Reach The Lower Pole Of The Kidney, Should Have Hybrid Grasper Enables Head On Capture Of Small 1Mm Stones Similar To Dakota® , Disposbale Lightrail Fibre 230 Compatiable With Auriga 30W Holmium Laser , Disposbale Lightrail Fibre 365 Compatiable With Auriga 30W Holmium Laser , Disposbale Lightrail Fibre 270 Compatiable With Auriga 30W Holmium Laser , Disposbale Lightrail Fibre 600 Compatiable With Auriga 30W Holmium Laser , Non Consumable - General Instruments , Farabuef Rectractor , Roux Rectractor , Senn Rectractor , Wound Retractor Disposable Hand Assist Tunnelsused For Enlarging The Wound Visibility, Wound Protection And Reduce The Wound Infection During Endoscopic Surgery, Gynecology Laparoscopic Procedure And Small Incision Surgery 270Mm , Pcn Needle 25 Cm , Pcn Needle 15 Cm , Stainless Steel Trocar And Canula With A Slot For Performing Suprapubic Cystostomy Using A Standard 14F Latex Foley Catheter , Stainless Steel Trocar And Canula With A Slot For Performing Suprapubic Cystostomy Using A Standard 12F Latex Foley Catheter , Measuring Scale With Markings In Cm And Inches, 6 Inches Long Made Of Surgical Grade Stainless Steel , Weighted Vaginal Speculum With Weights Made Of High Quality Surgical Grade Stainless Steel , Yankauer Suction Tip Length 12 1/2 (31.8 Cm) Made Of High Quality Surgical Grade Stainless Steel , Frazier Suction Tube With Finger Cut-Off 7 Fr. Made Of High Quality Surgical Grade Stainless Steel , Frazier Suction Tube With Finger Cut-Off 10 Fr. Made Of High Quality Surgical Grade Stainless Steel , Angled Bp Handle (10 To 15 Degrees), No. 3 Size, 250 Mm (10 Inches) Long Made Of Surgical Grade Stainless Steel , Reusable Open Small Clip Applier Right Angled 28Cm Compatible With Ethicon™ Small Titanium Alloy Clips (Lt100) , Reusable Open Small Clip Applier Straight28cm Compatible With Ethicon™ Small Titanium Alloy Clips (Lt 100) , Reusable Open Medium Clip Applier Angled26cm Compatible With Ethicon™ Medium Titanium Alloy Clips (Lt 200) , Reusable Open Medium -Large Clip Applier Straight28cm Compatible With Ethicon™ Medium Large Titanium Alloy Clips (Lt 300) , Reusable Open Medium -Large Clip Applier Angled28cm Compatible With Ethicon™ Medium Large Titanium Alloy Clips (Lt 300) , Reusable Open Medium -Large Clip Applier Right Angled28cm Compatible With Ethicon™ Medium Large Titanium Alloy Clips (Lt 300) , Reusable Open Large Clip Applier Straight28cm Compatible With Ethicon™Large Titanium Alloy Clips (Lt 400) , Reusable Open Large Clip Applier Angled28cm Compatible With Ethicon™ Large Titanium Alloy Clips (Lt 400) , Reusable Open Large Clip Applier Right Angled28cm Compatible With Ethicon™Large Titanium Alloy Clips (Lt 400) , Reusable Open Medium Hemolock™ Clip Applier Angled28cm , Reusable Open Medium Hemolock™ Clip Applier Straight28cm , Reusable Open Large Hemolock™ Clip Applier Angled28cm , Reusable Open Large Hemolock™ Clip Applier Straight28cm , Reusable Open Extra Large Hemolock™ Clip Applier Angled28cm , Reusable Open Extra Large Hemolock™ Clip Applier Straight 28Cm , Curved 11 Inch Hem-O-Lok Clip Applier Suitable For Large Hem-O- Lok Clips For Open Surgery , Right Angle (70 Degree) 11 Inch Hem-O-Lok Clip Applier Suitable For Large Hem-O- Lok Clips For Open Surgery , Curved 11 Inch Hem-O-Lok Clip Applier Suitable For Extra Large Hem-O- Lok Clips For Open Surgery , Right Angle (70 Degree) 11 Inch Hem-O-Lok Clip Applier Suitable For Extra Large Hem-O- Lok Clips For Open Surgery , Spencer Wells Artery Forceps 7 Box Joint Curved Of High Quality Surgical Grade Stainless Steel , Spencer Wells Artery Forceps 7 Box Joint Straight Of High Quality Surgical Grade Stainless Steel , Heiss Artery Forceps Straight 8 Inches Long Made Of High Quality Surgical Grade Stainless Steel , Heiss Artery Forceps Curved 8 Inches Long Made Of High Quality Surgical Grade Stainless Steel , Right Angled Forceps 8 Inches Long With Short 5Mm Long Fine Tip Made Of High Quality Surgical Grade Stainless Steel , Right Angled Forceps 9 Inches Long With Short 5Mm Long Fine Tip Made Of High Quality Surgical Grade Stainless Steel , Right Angled Forceps 10 Inches Long With 15Mm Long Fine Tip Made Of High Quality Surgical Grade Stainless Steel , Mixter Forceps Longitudinal Serrations 11 Inch, 1.5 Mm Fine Tip- The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Sponge Holder Box Joint 10 Of High Quality Surgical Grade Stainless Steel , Allis Tissue Forceps Box Joint 8 Of High Quality Surgical Grade Stainless Steel , Babcock Intestinal Forceps 8 Box Joint Of High Quality Surgical Grade Stainless Steel , Angled (20 To 30 Degree) Babcock Forceps 9 Inches Long Of High Quality Surgical Grade Stainless Steel , Mayo Towel Clip 5 And 1/2 Inches Long Made Of High Quality Surgical Grade Stainless Steel , Adson Forceps 4.5Inch Long Non-Tooth Serrated Jaws Of High Quality Surgical Grade Stainless Steel , Adsons Forceps 4.5 Inch Long, 1X2 Teeth, 1.4Mm Tip Of High Quality Surgical Grade Stainless Steel , Adsons Forceps 4.5 Inch Long, Ring Tip Of High Quality Surgical Grade Stainless Steel , Stainless Steel Cheatles Forceps 10 And 1/2 Inches Long , Deaver Retractor, 2” Wide, 7” Working Length, 13” Long Of High Quality Surgical Grade Stainless Steel , Deaver Retractor- 3 Inch Widthx 14 Inch Long Blade Made Of High Quality Surgical Grade Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Deaver Retractor- 4 Widthx 12 Long Blade Made Of High Quality Surgical Grade Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Langenbeck Retractor - 25Mm X 6Mm Made Of High Quality Surgical Grade Stainless Steel , Langenbeck Retractor -35Mm X 11Mm Made Of High Quality Surgical Grade Stainless Steel , Langenbeck Retractor -45Mm X 18Mm Made Of High Quality Surgical Grade Stainless Steel , Czerny Retractor Made Of High Quality Surgical Grade Stainless Steel , Senn-Miller Wound Retractor With 18X6mm Blade 6.5Inches Long Of High Quality Surgical Grade Stainless Steel , Reusable Scots Perineal Retractor Frame With Hinge Made Ofhigh Quality Stainless Steel With 5 Sets Of Hooks, Each Set Being In A Separate Sterile Pack Meant For A Single Use And Containing 8 Hooks. , Balfour Transplant Retractor- Adult Size Two Fenestrated Blades Round(Not Sharp) , Blades 7Cm, Overall Length Of Arms 20 Cm , 17 Cm Spread Made Of High Quality Surgical Grade Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Blade For Balfour Transplant Retractor Not Convex Vertical Blade 10Cm Height X 7Cm Width Made Of High Quality Surgical Grade Stainless Steel. The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Stainless Steel Tray With Lockable Lid And With A Silicone Mat For Storing And Sterilization Of Microsurgical Instruments Of Size 30Cm X 20Cm X 15Cm. , Instruments Tray That Is Lockable Made Of Durable Medical Grade Plastic That Can Withstand Sterilisation With Suitable Silicone Mat And Holdersfor Sterilising Laparoscopic Instruments Using Plasma Sterilisation (Sterrad™) Of Size -60Cm X 30Cm X 25Cm , Gluteraldehyde (Like Cidex) Sterilisation Tray Made Of Durable Plastic Of Dimensions Lxbxh=80Cmx20cmx20cm With Inner Sieve Like Tray With Handle For Immersing And Removing Instrumentsspecifications I) The Gluteraldehyde (Like Cidex) Sterilisation Tray Must Be Made Of Durable Plastic Ii) The Tray Must Have Dimensions Lxbxh=80Cmx20cmx20cm Iii) There Must Be A Well Fitting Inner Sieve Like Tray With Handle For Immersing And Removing Instruments Iv) There Must Be A Lid For The Tray , Jefferson Dural Toothed Forceps, Fine 1 X 2 Teeth 7 Inches (178Mm)Made Of Stainless Steel With The Manufacturer Name And Catalog Number Engraved On The Instruments , Halsted Mosquito Forceps 5 Inches Curved Made Of Stainless Steel With The Manufacturer Name And Catalog Number Engraved On The Instruments , Halsted Mosquito Forceps 5 Inches Straight Made Of Stainless Steel With The Manufacturer Name And Catalog Number Engraved On The Instruments , Bone Nibbler Double Action Straight 190Mm Made Of High Quality Stainless Steel With The Manufacturer Name And Catalog Number Engraved On The Instruments , Bone Nibbler Double Action Angular 190Mm Made Of High Quality Stainless Steel With The Manufacturer Name And Catalog Number Engraved On The Instruments , Mayo Trolley With Adjustable Height Made Of High Quality Stainless Steel Of 90Cm X 80 Cmand Height Of 100Cmincluding Wheels , Surgical Instrument Trolley Made Of High Quality Stainless Steel Of 90Cm X 80Cmand Height Of 80Cmincluding Wheels , Heavy Base Iv Stand With Wheels To Withstand 6Ltrs Of Saline Or Glycine Made Of Highquality Stainless Steel. , Heavy Base Iv Stand With Wheels To Withstand 6Ltrs Of Saline Or Glycine Made Of Castiron. , Mayo Scissors Curved 7 Inches Should Be Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Metzenbaum Scissors8 Inch Tungstan Carbide Tip Made Of High Quality Stainless Steel- The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Metzenbaum Scissors 11-1/4 Inch Tungstan Carbide Tip Made Of High Qualtiy Staninless Steel - The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Cushing Vein Retractor Matte Finish 9 Inch-The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Rigid Triprong Stone Removal And Stent Removal Compatible With Standard Semi-Rigid Ureterscope 6.5/8 Fr Single Channel, 4.5 Fr Channel Size That Accommodates 4 Fr Instrument, 5°, 430Mm Working Length , Rigid Forceps For Stent Removal Compatible With Olympus Cysto Nephro Video Scope (Cyf-Vh) , Laparoscopy Instruments , Lap, Fenistrated, Non-Trumatic Bowel Grasper 5Mm , Lap Toothed Forceps With Rachet 5Mm , Lap Reducer 5 - 10 Mm , Lap Disposable Scissors 5Mm , Monopolar Working Element - Karl Storz Passive 27050E , Grasping Forceps 4 Fr For Stent Removal , Hebsons Rectractor Set , Laparoscopic Vascular Bulldog Clam With Applicator , Lap Suction Trumphet Long 45 Cm And Above , 10Mm Complete, Smooth,Trocar,10Mm,11Cm, With Pyramidal Tip And10mm Blunt Trocar For Complete Trocar Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument With 5 Spare Rubber Caps. , 5Mm Bariatric Laparoscopic Suction Irrgation Cannula With Trumpt Valve (50Cm Or Longer) , Lazy “S” Retractors Used In Laparoscopic Port Insertion By Open Technique- 10Mm Wide, 18 Cm Long, Set Of Two Made Of High Quality Surgical Grade Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , ‘S’ Retractor (Double Ended Retractor)- Blade A 6 Mm X 10 Mm Deep, Blade B 13.5 X 15 Mmdeep, Overall Length- 13.5 Mm Made Of High Quality Surgical Grade Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Hassan “S” Retractors Used In Laparoscopic Port Insertion By Open Technique- 10Mm Wide, 18 Cm Long, Set Of Two Made Of High Quality Surgical Grade Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Hassan “S” Retractors Used In Laparoscopic Port Insertion By Open Technique- 13 Mm Wide, 18 Cm Long, Set Of Two Made Of High Quality Surgical Grade Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Laparoscopic Reusable & Autoclavableright Angled Forceps Without Ratchet -10Mm 31 Cm Long (The Inner Working Length Of The Jaws From Tip To Angle Must Be At Least 5Mm) Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Reusable & Autoclavable 5Mm Clip Applicator For Medium (Green) Straight Hemolock ™Type Clips Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Reusable & Autoclavable 10Mm Clip Applicator For Large (Purple) Straight Hemolock ™Type Clips Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Reusable & Autoclavable 10Mm Clip Applicator For Large (Purple) Angled 20 Deg Hemolock ™Type Clips Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Reusable & Autoclavable 10Mm Clip Applicator For Large (Purple) Angled 45 Deg Hemolock ™Type Clips Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Reusable & Autoclavable Clip Applicator 10Mm For Extra Large (Gold/Yellow) Hemolock ™Type Clips Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Reusable & Autoclavablesuction Irrigation 2-Way Trumpet Valve 5Mm Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Carter Thomason Type Port Closure Needle 16G, 15 Cm Long Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Reusable & Autoclavable10mm Trocar Blunt Tip And Cannula Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Reusable & Autoclavable10mm Trocar Sharp Tip And Cannula Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Stainless Steel Reusable & Autoclavable12mm Trocar And Cannula Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Stainless Steelreusable & Autoclavable10mm Hason Cannula With Cone Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Stainless Steel Reusable & Autoclavabletrocar And Cannula For 5Mm Instrument, 10Cm Long Sharp Tip Made Of High Quality Stainless Steel With 5 Spare Rubber Caps. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Metzenbaum Scissors, Serrated, Tungsten Coated Inserts, 5Mm, 31Cm,Reusable & Autoclavable Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Premium Metzenbaum Scissors, Serrated, Tungsten Coated Inserts, 5Mm, 31Cm,Reusable & Autoclavable Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Tungsten Carbide Coated, Needle Holder, Straight, 5Mm, 31Cm Light Weight Black Handle With Ratchetreusable & Autoclavable Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopicsuction/Irrigation Tube 40 Cm,Reusable & Autoclavable Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Maryland Dissection Forceps, Insulated To Tip, 5Mm, 31Cmreusable & Autoclavable Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic Bowel Grasping Forceps, 20Mm Jaw, 5Mm, 31Cmreusable & Autoclavable Made Of High Quality Stainless Steel The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Laparoscopic 5Mm Satinsky Clamp The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Endoscopy Instruments , Stainless Steel Tri-Prong Ureteroscopic Semirigid Straight Stone Holding Forceps With Spring Action Handle 4F/70Cm For Ursl Procedure , Stainless Steel Tri-Prong Ureteroscopic Semirigid Straight Stone Holding Forceps With Spring Action Handle 5F/70Cm For Ursl Procedure , Stainless Steel Ureteroscopic Semirigid Straight Stone Grasping Forceps With Alligator Jaws 4F - For Ursl Procedure , Stainless Steel Ureteroscopic Semirigid Straight Stone Grasping Forceps With Alligator Jaws 5F - For Ursl Procedure , Stainless Steel Tri-Prong Stone Holding Forceps With Spring Action Handle 10Fr Diam 40Cm Long - For Pcnl Procedure , Stainless Steel Flat Blade Stone Holding Forceps With Spring Action Handle 10Fr Diam 40Cm Long- Pcnl Procedure , Stainless Steel Alligator Stone Holding Forceps With Double Action Serrated Jaws 10Fr Diam 40Cm Long - For Pcnl Procedure , Alligator Jaw Stone Crushing Optical Forceps Made Of Stainless Steel With Compatible Autocalavable Sheath- 25Fr And Obturator. The Forceps Should Be Compatible With Storz™ Cystoscope Sheath , Otis Urethrotome - Knife, Compatible With Karl Storzotis Mauermayer Urethrotome(27578A) , Stone Grasping Forceps Small With Alligator Jaws Consisting Of Handleand Insert With Sheath Compatible With Miniature Nephroscope 15F Mfd. By M/S. Richard Wolf Gmbh, Germany , Stainless Steel, Cystoscopicinjection Needle 37 Cm, 5F For Use Through A Storz Cystoscope Sheath Working Channel , 20F Cystoscope Sheath With Two Luer Lock Channels With Matching Obturator, Both Made Of Stainless Steel Compatible With A Karl Storz, Germany Make Adult Cystoscope System. , Stone Crushing Forceps Made Of Stainless Steelwith Single Action Jaw Compatible With A Karl Storz, Germany Make 23.5F Cystoscope Sheath. , Cold Cup Optical (Cystoscopic ) Biopsy Forceps Made Of Stainless Steel With Double Action Jaws Compatible With A Karl Storz, Germany Make 20F Adult Cystoscope System. , Fiber Optic Endoscope Light Cable 4.5 Mm Diam 200Cm Length Compatible With Storz™ Light Source. (Cable Should Be Capable Of Being Steam Autoclaved, Gas Sterilized Or Cold Soaked For Sterilization) , Fiber Optic Endoscope Light Cable 4.5 Mm Diam 200Cm Length Compatible With Stryker /Wolf ™ Light Source. (Cable Should Be Capable Of Being Steam Autoclaved, Gas Sterilized Or Cold Soaked For Sterilization) , Fiber Optic Endoscope Light Cable 4.5 Mm Diam 200Cm Length Compatible With Olympus Light Source ((Otv 190, Otv200,Otv300) ™ Light Source. (Cable Should Be Capable Of Being Steam Autoclaved, Gas Sterilized Or Cold Soaked For Sterilization) , Inner Sheath Rotating With Ceramic Insulation For Use With Resectoscope Outer Of 26 Fr. Compatible With Karlstorz Working Element , Light Guide Adapter For Olympus Led Light Source Otv S200, Otv S190 , Transplant Instruments , Straight Ring Tipped Micro Forceps, Made Of High Quality Stainless Steel With Diameter Of The Ring 1.5Mm, Total Length 21 Cm With Rounded Blades For Hand Grip, With Counter Balance, With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight Ring Tipped Micro Forceps, Made Of High Quality Stainless Steel With Diameter Of The Ring 1.5Mm, Total Length 23 Cm With Rounded Blades For Hand Grip, With Counter Balance, With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight Ring Tipped Micro Forceps, Made Of High Quality Stainless Steel With Diameter Of The Ring 1.5Mm, Total Length 25 Cm With Rounded Blades For Hand Grip, With Counter Balance, With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight Platform Tipped Microforceps Made Of High Quality Stainless Steelof 21 Cm Length, Rounded Blades For Hand Grip, With Counter Balance, With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight Platform Tipped Microforceps Made Of High Quality Stainless Steelof 23 Cm Length, Rounded Blades For Hand Grip, With Counter Balance, With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight Platform Tipped Microforceps Made Of High Quality Stainless Steelof 25 Cm Length, Rounded Blades For Hand Grip, With Counter Balance, With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight Needle Holder Made Up Of High Quality Stainless Steel, Coated With Diamond Dust Slender Jaws, Should Hold Needles Of 6 ‘O’ To 7 ‘O’ Sutures With Good Grip, Jaw Length 1.5 Cm, Total Length 220Mmwith Ring Handle, With Ratchets With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Castroviezo Staight Needle Holder Withcatch With Diamond Dust Jaws 18 Cm Long Made Up Of High Quality Stainless Steel. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Castroviezo Straight Needle Holder Withcatch With Diamond Dust Jaws 21 Cm Long Made Up Of High Quality Stainless Steel. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Castroviezo Staight Needle Holder Withcatch With Diamond Dust Jaws 23 Cm Long Made Up Of High Quality Stainless Steel. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Castroviezo Staight Needle Holder Withcatch With Diamond Dust Jaws 25 Cm Long Made Up Of High Quality Stainless Steel. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Barraquer Micro Needle Holder With Catch And Straight Jaws 4.5 Inches Long Of High Quality Surgical Grade Stainless Steel For Bench Surgery , Debakey Vascular Forceps Made Of Titaniumtapered Tip To 1.5 Mm Of Length 9 ½ Inch (241 Mm) Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Debakey Vascular Forceps Made Of Titaniumtapered Tip To 1.5 Mm Of Length 12 Inch (305 Mm) Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Gerald – Debakey Ring Tip Forceps Tip Size 1Mm, Length 8 Inches Made Of High Grade Stainless Steel Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Gerald – Debakey Tissue Light Weight Round Handle Forceps Tip Size 1Mm, Length 71/4 Inches (184 Mm) Made Of Titanium Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Micro Tissue Forceps, Straight Made Of High Grade Stainless Steel With Fine Tungsten Carbide Dust Tips, 1.0 Mm Tip With Platform, Counter Balanced 210 Mm Length Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Micro Tissue Forceps, Straight Made Of High Grade Stainless Steel With Fine Tungsten Carbide Dust Tips, 1.0 Mm Tip With Platform, Counter Balanced 229 Mm Length Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Micro Tissue Forceps, Straight Made Of High Grade Stainless Steel With Fine Tungsten Carbide Dust Tips, 1.0 Mm Tip With Platform, Counter Balanced 254 Mm Length Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Jacobson Fine Micro Needle Holder Titanium, Fine Tungsten Carbide Dust Tips, Straight, Flat Handle Of Length 9 Inches Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Jacobson Fine Micro Needle Holder Titanium, Fine Tungsten Carbide Dust Tips, Curved, Flat Handle Of Length 8 Inches Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Jacobson Fine Micro Needle Holder Titanium, Curved Tips, Fine Tungsten Carbide Dust Tips, Flat Handle With Ratchet,Length 9 Inch- The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Castroviejo Style Microsurgical Needle Holders, Straight, Tungsten Carbide Tip, Round Handle, With Ratchet, 23 Cm Long, 1Mm Tips, For Use With 5.0, 6.0 And 7.0 Suture- The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Castroviejo Style Microsurgical Needle Holders, Curved, Tungsten Carbide Tip, Round Handle, With Ratchet, 23 Cm Long, 1Mm Tips, For Use With 5.0, 6.0 And 7.0 Suture- The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Castroviejo Style Microsurgical Needle Holders, Straight,Tungsten Carbide Tip, Flat Handle, With Ratchet, 23 Cm Long-Bite 1Mm Tips, For Use With 5.0, 6.0 And 7.0 Suture- The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Debakey-Diethrich Forceps With Fine Tungsten Carbide Dust Tip 9-1/2, Tip 1Mm-The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Vascular Instruments , Harken Auricle Clamp 23 Cm , De Bakey Atraumatic Dissecting Forceps Of 3.5Mm Wide Tip And Dimension Of 200 Mm. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , De Bakey Atraumatic Dissecting Forceps Of 3.5Mm Wide Tip And Dimension Of 240 Mm. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , De Bakey Atraumatic Dissecting Forceps Of 3.5Mm Wide Tip And Dimension Of 300 Mm. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , De Bakey Atraumatic Dissecting Forceps Of 2Mm Wide Tip And Dimension Of 150 Mm. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , De Bakey Atraumatic Dissecting Forceps Of 2Mm Wide Tip And Dimension Of 200 Mm. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , De Bakey Atraumatic Dissecting Forceps Of 2Mm Wide Tip And Dimension Of 240 Mm. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , De Bakey Atraumatic Dissecting Forceps Of 2Mm Wide Tip And Dimension Of 300 Mm. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Debakey Atraumatic Forceps 195Mm Long, 1Mm Tip Of High Quality Surgical Grade Stainless Steel With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight, Light Weight, Tapered Tip Debakey Type Vascular Forceps With 1:2 Serrations Of Total Length 24 Cm, Tip Width Around 1Mm, With Rounded Blades For Hand Grip, With Counter Balance, With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , De Bakey Vascular Dilator Set (Set Of Ten Dilators With Diam 1Mm, 1.5Mm, 2.0Mm, 2.5Mm, 3.0Mm, 3.5Mm, 4Mm, 4.5Mm, 5Mm And 7Mm) With Malleable Shaft. Length Of Each Dilator Is 19Cm Made Of High Quality Stainless Steel , Cooley Non-Traumatic Vascular Clamp Angled 90 Degree With 4 Cm Long Jaws 5 Inches Long Of High Quality Surgical Grade Stainless Steel With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Angled, Atraumatic Vascular Occlusion Clamp With Inner Jaw Of Debakey Type(1:2 Serrations), With An Angle Of 60 Degrees, Working Length Of Clamp Of Minimum 6.5Cm And Total Length Of 18 Cm, With Ring Handle And Ratchet, With Non-Reflecting Surface With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight, Atraumatic Vascular Occlusion Clamp With Inner Jaw Of Debakey Type(1:2 Serrations), Working Length Of Clamp Of Minimum 6.5Cm And Total Length Of 18 Cm, With Ring Handle And Ratchet, With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Atraumatic Satinsky Type Tangential Occlusion Clamps With Inner Jaw Of Debakey Type(1:2 Serrations), With Wide Angle U Shaped Occlusion Area, With44 Mm Distance Between Tip Of The Instrument And Starting Of The Working Length Respectively. Should Have Ring Handle 9 Inches Long With Ratchet, Should Be Made Of High Quality Stainless Steel, Should Be Non-Reflecting. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Atraumatic Satinsky Type Tangential Occlusion Clamps With Inner Jaw Of Debakey Type(1:2 Serrations), With Wide Angle U Shaped Occlusion Area, With 50 Mm Distance Between Tip Of The Instrument And Starting Of The Working Length Respectively. Should Have Ring Handle 9 Inches Long With Ratchet, Should Be Made Of High Quality Stainless Steel, Should Be Non-Reflecting The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Atraumatic Satinsky Type Tangential Occlusion Clamps With Inner Jaw Of Debakey Type(1:2 Serrations), With Wide Angle U Shaped Occlusion Area, With63 Mm Distance Between Tip Of The Instrument And Starting Of The Working Length Respectively. Should Have Ring Handle 9 Inches Long With Ratchet, Should Be Made Of High Quality Stainless Steel, Should Be Non-Reflecting. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight Needle Holder Made Up Of High Quality Stainless Steel, With Tungsten Carbide Coated Slender Jaws, Should Hold Needles Of 5 ‘O’ To 7 ‘O’ Sutures With Good Grip, Jaw Length 1.5 Cm, Total Length 21Cm, With Ring Handle, With Ratchets With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight Needle Holder Made Up Of High Quality Stainless Steel, With Tungsten Carbide Coated Slender Jaws, Should Hold Needles Of 5 ‘O’ To 7 ‘O’ Sutures With Good Grip, Jaw Length 1.5 Cm, Total Length 23Cm, With Ring Handle, With Ratchets With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Straight Needle Holder Made Up Of High Quality Stainless Steel, With Tungsten Carbide Coated Slender Jaws, With Good Grip, Jaw Length 1.5 Cm, Total Length 25Cm, With Ring Handle, With Ratchets With Non-Reflecting Surface. The Instrument Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Potts Smith Scissors 45 Deg Angle 9 Long Of High Quality Surgical Grade Stainless Steel With Non-Reflecting Surface. The Instruments Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Potts Smith Scissors 9 Bent On Flat At 90 Deg Angle Of High Quality Surgical Grade Stainless Steel With Non-Reflecting Surface. The Instruments Must Be Of International Standards Having At Least One Of The International Standards Such As Ce, Bis And Din. The Manufacturers Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument , Micro Forceps Non-Tooth Angled 6 Inches Long Of High Quality Surgical Grade Stainless Steel For Avf , Micro Forceps Non-Tooth Straight 6 Inches Long Of High Quality Surgical Grade Stainless Steel For Avf , Castroviejo Micro Needle Holder With Catch And Straight Jaws 6 Inches Long Of High Quality Surgical Grade Stainless Steel For Avf , Iris Scissors Curved 4.5 Inches Long Of High Quality Surgical Grade Stainless Steel , Iris Scissors Straight 4.5 Inches Long Of High Quality Surgical Grade Stainless Steel , Micro Scissors Spring Type, Round Handle With Serrations 6 Inch Long Straight Of High Quality Surgical Grade Stainless Steel For Avf , Micro Scissors Spring Type, Round Handle With Serrations 6 Inches Long Curved Of High Quality Surgical Grade Stainless Steel For Avf , Mcdougal Prostatectomy Clamps- Used In Securing Dorsal Vein Complex In Radical Prostatectomy - - Angled Right 2.5 Cm Tip,Length25 Cm Made Of High Quality Surgical Grade Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Mcdougal Prostatectomy Clamps- Used In Securing Dorsal Vein Complex In Radical Prostatectomy - - - Angled Left 2.5 Cm Tip, Length 25 Cmmade Of High Quality Surgical Grade Stainless Steel The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Debakey Vascular Dilators Set: Sets Of Dilators In Graduated Sizes, 1, 1.5, 2, 2.5, 3, 4, 5, 6, 7, 8, 9 And 10 Mm And Length Of 7-1/2 (19 Cm) With Autoclavable Steel Case The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Julian Plus Classicr Needle Holder High Grade Stainless Steel With Fine Tungsten Carbide Duststraight 81/4 Inch (210 Mm) Imported With Fda, European Ce Certification With The Manufacturer Name And Catalog Number Engraved On The Instruments , Low Ryder Micro Needle Holder With Diamond Dust Coat Of Tip, Straight, Light Weight, For Holding 5’0- 7’0 Sutures15cm- The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Low Ryder Micro Needle Holder With Diamond Dust Coat Of Tip, Straight, Light Weight, For Holding 5’0- 7’0 Sutures21cm- The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Castroveijo Micro Scissors, Straight – 5 1/2 Inches For Bench Surgery- The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Castroveijo Micro Scissors, Curved – 5 1/2 Inches For Bench Surgery-The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Debakey Harken Clamp, Curved, For Ivc Looping, 9 Inch-The Instrument Must Be Of International Standards Having International Standards Such As Fda, Bis And Din. The Manufacturer’S Name Or Brand, Catalogue Number And Certification Details Should Be Engraved On The Instrument. , Common Consumables Items , Hme Filters , Disposable Pressure Transducer - Compatible With Ge/Lt Monitors , Nebulizer Mask With Tubing (Online Nebulized) Adult , High-Pressure Monitoring Line (30 Cms, 50 Cms, 100 Cms, 150 Cms, 200 Cms) (Male-Female) Made Up Of Pvc (50/Pack) , High-Pressure Monitoring Line (30 Cms, 50 Cms, 100 Cms, 150 Cms, 200 Cms) (Male-Male) Made Up Of Pvc (50/Pack) , Pressure Bag (Pressure Infusion Cuff) 500 Ml With Pressure Gauge , Face Mask For Oxygen Therapy , Ecg Pre Gel Electrod (50/Pack) , Echo Gel/Ultra Sound Gel (50/Pack) , Urine Collecting Transparent Bag With Attached Spigot, With Seprate Urine Aspiration Site For Culture And Measuring Chamber (Urinometer) Of The Capacity At Least 150 Ml To Enable Measuring Hourly Urine Output And Total Bag Capacity Of 1.5 To 2 Liter With Connector For Urine Catheter With Tube Length Of At Least 1 Meter , Ultrasonic 5Mm, Laparoscopic Curved Blade Shaft Length 36Mm With Advance Hemostasis (Seal Upto 7Mm Vessel) Compatible With Gen 11 , Ultrasonic 5Mm, Laparoscopic Curved Shear With Integrated Transducer, Shaft Length 36Mm Indication For Dissection, Grasping, Coagulation, Cutting And Coagulation Upto Including 7 Mm Vessels, Minimal Thermal Injury And Utilizes Adaptive Tissue Technology , Incentive Spirometer - Three Ball Type Graduation With Inspiration And Expiration Type Of Ball Movement For Breathing Exercises- With Detachable Parts To Enable Cleaning , Suction Catheter (Sterile) (Pack Size - Box Of 10 Units) 12, 14 & 16 Fr , Three Way Stop Cock With Extension 150 Cms Stop Cock Should Have Polycarbonate Body With Male Luer Lock Nut And Polyethylene Luer Caps. Flow Rate: Straight: 650-700 Ml / Min; Side Port: 450 - 500 Ml / Min (Low Pressure) (10/Pack) , Three Way Stop Cock With Extension 200 Cms Stop Cock Should Have Polycarbonate Body With Male Luer Lock Nut And Polyethylene Luer Caps. Flow Rate: Straight: 650-700 Ml / Min; Side Port: 450 - 500 Ml / Min (Low Pressure) (10/Pack) , Cvp Catheter (Triple Lumen) - 7 Fr., 12-15 Cms,. Full Set Guide With Spring Guide Wire - Seldinger Type, Introducer Needle(18 Gauge), Syringe, Catheter Clamp, Dilator , Advanced Bipolar Probe With Ptc Techonogy Round Tip- 25Cm Compatiable With Gen 11 , Advanced Bipolar Probe With Ptc Techonogy 3Mm Curved Round Tip- 25Cm Compatiable With Gen 11 , Advanced Bipolar Probe With Ptc Techonogy Straight Jaw 35Cm With Articulation Compatiable With Gen 11 , Advanced Bipolar Probe With Ptc Techonogy Super Jaw Compatiable With Gen 11 , Linear Cutter 55 - 60 Mm 3 Staggered Row With Selectable Staple Height , 3 Staggered Blue Reloads For Linear Cutter 55- 60 Mm, Compatible With Above Linear Cutter , Linear Cutter 75 - 80 Mm 3 Staggered Row With Selectable Staple Height , 3 Staggered Blue Reloads For Linear Cutter 75 80 Mm, Compatible With Above Linear Cutter , Linear Cutter 100 Mm Inbuilt Knife With 2.0Mm Cartridge , Blue 2.0Mm Reloads For Linear Cutter 100Mm, Compatible With Above Linear Cutter , Tri-Staple Gia 60Mm -Three Staggered Rows With In Build New Knife Blade Purple Medium/Thick Reload With Tri-Staple™ Technology Having Staple Height Of 3.0 Mm, 3.5 Mm, And 4.0 Mm , Tri-Staple Gia 60Mm-Three Staggered Rowspurple Medium/Thick Gia™ Stapler With Tri-Staple™ Technology , Tri-Staple Gia 80Mm -Three Staggered Rows With In Build New Knife Blade Purple Medium/Thick Reload With Tri-Staple™ Technology Having Staple Height Of 3.0 Mm, 3.5 Mm, And 4.0 Mm , Tri-Staple Gia 80Mm-Three Staggered Rowspurple Medium/Thick Gia™ Stapler With Tri-Staple™ Technology , Disposable Laparoscopic Clip Applicator 5 Mm With 15 Preloaded Medium-Large Clips Available With Colour Code Indicator For Last Clip , Disposable Laparoscopic Clip Applicator 10 Mm With 20 Preloaded Medium-Large Clips Available With Colour Code Indicator For Last Clip , Automatic Core Biopsy Gun - 18G X 25Cm - Should Be Spring Loaded Fully Automatic Biopsy Gun - Should Have One Handed Cocking Mechanism With Non-Roll Handle Design. - Should Have Angled Sample Notch For Enhanced Needle Action. - Instrument Should Have Choice Of Two Firing Buttons, One On The Body And One On The Rear End - Should Have Double Press Cocking Mechanism. - Should Have Penetration Depth Of 22 Cm And Core Sample Should Be 19Mm , Automatic Core Biopsy Gun - 18G X 16Cm - Should Be Spring Loaded Fully Automatic Biopsy Gun - Should Have One Handed Cocking Mechanism With Non-Roll Handle Design. - Should Have Angled Sample Notch For Enhanced Needle Action. - Instrument Should Have Choice Of Two Firing Buttons, One On The Body And One On The Rear End - Should Have Double Press Cocking Mechanism. - Should Have Penetration Depth Of 22 Cm And Core Sample Should Be 19Mm , Shoes Crocs Type For Surgeons, Light Weight 7,8,9 Size , Disposable Surgeon Leggings For Turp Specification: Upper Thigh Length Size, Plastic Impervious , Gluteraldehyde (Like Cidex) Sterilisation Tray Made Of Durable Plastic Of Dimensions Lxbxh=71Cmx12cmx17cm With Inner Sieve Like Tray With Handle For Immersing And Removing Instruments Specifications I) The Gluteraldehyde (Like Cidex) Sterilisation Tray Must Be Made Of Durable Plastic Ii) The Tray Must Have Dimensions Lxbxh=71Cmx12cmx17cm Iii) There Must Be A Well Fitting Inner Sieve Like Tray With Handle For Immersing And Removing Instruments Iv) There Must Be A Lid For The Tray , Clip Applicator Weck Hemolock Laparoscopic-Large Size, 10Mm 33Cm , Clip Applier Large With 20 Preloaded Clips For Open Surgery , Clip Applier Medium With 20 Preloaded Clips For Open Surgery , Clip Applier Small With 20 Preloaded Clips For Open Surgery , Clips Hemo Lock (L) (Purple) , Clips Hemo Lock (Medium) (Green) , Clips Hemo Lock (Xl) (Golden) , Disposable Hemolock Clip Applicator , Disposable Pressure Transducer - Compatablie To Ge/L&T Monitors , I.V Transparent Dressings (Transparent Polyurethane Film With One Half Laminated With Soft Cloth Backing For Enhanced Grip On Challenging I.V Applications. Should Also Have A Long Slit To Conform Around The I.V. Hub- Size 8.5 Cm X 11.5Cm , Dial Flow Like Device For Iv Fluids , Disposable Moulded Yankauer Suction Cannula Transparent With Tubing Atleast 2.5Mts , Disposable Sterile 3-Way Stop Cock (Pack Size - Box Of 50 Units) , Foley Catheter, Silicone 12F [100% Pure Silicone, 2 Way Bulb] , Foley Catheter, Silicone 14F [100% Pure Silicone, 2 Way Bulb] , Foley Catheter, Silicone 16F [100% Pure Silicone, 2 Way Bulb] , Bag Urostomy,Single Piece , (S) Disposable Gauze Pieces In (Eto Sterilizable)Packs Of 10 For Use With Cath Lab Procedures , Disposable Trolley Drape Laminated Absorbent Sheet 200Cm X 150Cm , Disposable Trolley Drape Double Layer Water Proof 200Cm X 150Cm , Disposable Sterile Surgical Gown - Air Permeable, Fluid Resistant, Skin Friendly, Non- Woven Fabric - In A Double Sealed Pack. 1. It Should Be Made Up Of Multilayered Fabric Of High Quality With Outer Thin Fluid Repellant Layer, Middle Layers For Fluid And Bacterial Control And The Inner Layer For Overall Strength. 2. It Also Should Be Of Light Weight Material - 43 To 45 Gsm. 3. The Design Should Be Roomy With Generous Length. 4. It Should Have Adjustable Neckline. 5. It Should Have Easy Hand Entry Features. 6. It Should Have Overlapping Back Features. 8. The Side Tie Should Have A Lengthy Paper Tag . 9. It Should Have Ultrasonic Bonded Seams . 10. A Hand Towel Made Up Of Spun Lace. 12. The Entire Gown Should Have Double Pack After Eto Steriliszation. 13. Spr , Glucose Test Strips For Blood Compatible Glucometer Should Besupplied Free Of Cost To All Wards, Labs And Services Where It Is Required.Free Repair/ Replacement Shoud Be Provided During The Period Of Use. , Patient Warming Device For Use On Patients Undergoing Surgical Operation Specificationsi) Intraoperative Temperature Management Unit For Forced-Air Warming. Ii) The Unit Should Provide Safe, Quiet And Effective Warming To The Patient. Iii)Should Be Light Weight Making Transport Easy. Iv) Should Be Freestanding As Well As Be Easily Attached To An Iv Pole Or Bedrail. V) Should Have Snap-Fit Hose Swivels In At Least Three Points For Easy Blanket Attachment And Positioning. Vi)Matching Adult Or Paediatric (As Per Buyer Choice)Upper Body Warming Blanket 3 Nos. Vii) Power Cord With Standard Indian Plug And Other Cables To Make The Equipment Functional. Viii) Should Work On 220Vac, 50Hz Power Supply Ix) Warranty: 3 Year , Portable Finger Spo2 Sensor Pulse Oximeter With Led Display , Perfusion Calula 18, 20, 22 Fr , Bacterial Filter , Nasal Prong , Iv Line Plaster , Tegaderm , Stapler Remover , Sputum Cup , Bains Circuit , Test Lung , Laryngoscope Adult (5 Set) , Ambu Bag -Adult , Ambu Bag -Paediatric , Triple Lumen Catheter , Asepto Syringe , Disposable Leg Cover (Size: 100 X 41 Cm, Material : Pe) , Disposable Poly Apron (Colour - Blue, Fabric - Plastic) , Gel Ports For Crushed Ice Insertion For Partial Nephrectomy And Transplant , Trumpet Type Suction (Bariatric Surgery Length) , Stratafix 3 0 17Mm Needle , Infusion Pump , Floor Suction Device For Operation Theater (This Is For Suctioning The Turp/Pcnl Irrigation Fluid In Ot.) , Patient Positioning Silicone/Deformable Polimer Gel Device ( Sacral Protector-Adult) , Patient Positioning Silicone/Deformable Polimer Gel Device (Flat Arm Board Pad-Adult) , Patient Positioning Silicone Gel/Deformable Polimer Device ( Heel Support Pad - Adult) , Patient Positioning Silicone/Deformable Polimer Gel Device (Dome - Flat Bottom Chest Roll - Adult) , Semi-Automatic Polythene Sealing Machine For Ldpe Specifications: 1. Machine Type: Continuous Sealer2. Automation Grade: Semi-Automatic 3. Sealing Operation Mode: Vertical4. Suitable For Packing Material: Ldpe5. Maximum Continuous Sealer Sealing Speed (In Meter/Min) : 5 6. Manual Sealer Sealing Speed (In Bags/Min): >=5<=10 7.Minimum Sealing Width (In Mm): 3,Maximum Sealing Width (In Mm): 5 & Maximum Sealing Length (In Mm): >750<=1000 8. Maximum Temperature: 200 Degree Celsius9. Heat Time: 3 Second 10.Power Supply: 230 V Single Phase & Power Consumption: 100 Watt 11. Outer Body Material: Stainless Steel 12. Temperature Adjustment Function: Yes13. Warranty For Complete Unit: 1 Year
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 47
32.
Drinking Water Supply and Sanitation #9199019 Technical Bid
Tender For The Work Of Construction Of Sources Rising Main Pl Cwrs Pump Houses Esrs Glsrs Internal Village Distribution Pipeline And Fhtc Including One Year Dlp Of Svs Under Jjm In The Dn Bagidora Under Distt Bans Pkg15 - Tender for the work of construction of Sources, Rising main pipelines, CWRs, Pump houses, ESRs, GLSRs, internal village distribution pipeline and FHTC including one year Defect Liability Period of SVS under JJM in the DN. Bagidora Under District-Banswara (Package-15) Sl. No. Item Description 1 Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge.excluding earth work)Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately 2 80 mm dia 3 100 mm dia 4 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in Meter measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.HDPE PE-100 PN-6 (Dia in mm) 5 75 mm dia 6 90 mm dia 7 110 mm dia 8 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work).Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in Meter measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.HDPE PE100 PN-6 (Dia in mm) 9 125 mm dia 10 160 mm dia 11 180 mm dia 12 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc. 13 In all types of Soils 14 upto 1.5 m 15 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable materials for measurements and disposal of unserviceable materials as directed within a lead of 50 Mtr. including required all safety provisions etc.: 16 In Soft Rock 17 upto 1.5 m 18 In Hard Rock (Blasting Required) 19 upto 1.5 m 20 In Hard Rock (Blasting Prohibited) 21 upto 1.5 m 22 Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. 23 Bituminous courses 24 Granular courses 25 Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasksas per technical specification and scope of work. 26 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 27 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mmnominal size). 28 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confiMetering to BS-EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confiMetering to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 29 80 mm dia 30 100 mm dia 31 150 mm dia 32 200 mm dia 33 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 34 Manually Operated CI Sluice valve of Class PN-1.0 35 100 mm dia 36 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 37 80 mm dia 38 100 mm dia 39 150 mm dia 40 200 mm dia 41 Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. 42 100 mm dia 43 Providing, lowering, aligning, fixing in position in pipe line, CIdouble flangedDual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications:Body & Cover of Grey cast iron ofIS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538.Epoxy (Non-Toxic & suitable for drinking water) applied on body & coverinside and outside . Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,SpringSS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.as per API: 594 and flanges as per ISS of approved makeof following Class and dia complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 44 Class PN 1.0 45 100 mm dia 46 Construction of Sluice Valve Chamber in required size and shape as per drawing including required excavationof earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in chargematerial within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge 47 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve 48 1200cm x 1200cm x 1300cm (depth) for 80/100/125/150 mm dia valve 49 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedupto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 50 Class PN 1.6 51 50 mm 52 Class PN 1.0 53 40 mm 54 50 mm 55 Supply, installation, testing and commissioning of DC submerssible pump sets with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and B9maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps.Solar pump shall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope. Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit,accidental short circuit and reverse polarity should be provided. A good reliable on/off switch suitable for DC use is to be provided. The cable shall be ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date.The duty condition of pump set shall be as per scope of work and entire work shall be as per technical specification and direction of Engineer in charge. 56 2.2 KW (3.0 HP) 57 Providing, installation, testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting for following staging and capacity of Rotational Moulded Polyethylene water storage tank on it as per indicative drawing given in the bid document. On the Polyethylene tanks, there shall be provision of suitable space for installation of solar panels up to 5.0 KW and further additional 2.5 KW on the side of Steel structure if required as per indicative drawing. Cost of solar panels is not included in this item. The structural steel shall be 120 micron hot dip galvanized iron and foundation of structure shall be in RCC with minimum depth as 2.0 mtr (other than rocky strata). The work includes P&F of Polyethylene Water Storage Tank(IS: 12701,ISI marked, indicating the BIS license No.) of approved make with cover.Providing & fixing 50 mm dia ISI marked G.I. class B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM gate valves at inlet and outlet pipe Including making connection etc. complete as per drawing, technical specification and direction of Engineer in In charge. The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank to ground and up to 2.0 mtr away from foundation and overflow pipe is to be interconnected in distribution pipe line. Wash out pipe shall be taken up to a suitable point minimum 5.0 mtr away from tank. Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled. Note: There shall be 5 year service warranty for structure, tank, fittings etc. and suitable provision shall be included in tender document. 58 5000 Liter X 2 Nos. PE water tank, staging 12 meter. 59 Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document. 60 Design, Fabrication and installation of MS galvanised structure for installation of Solar Penals at a height of 4m above ground level 61 Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document. 62 Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and structure, showing arrangement of panel on rectangular OHSR with flat roof/ MS fabricated structure with polyethylene tank and installation of PV module on above structure as per approved design and drawings. Mounting structure shall be suitably design to withstand wind velocity up to 150km/hr. The work shall be as per detailed technical specifications, approved drawing and direction of Engineer in Charge.This item does not include cost of OHSR/ MS fabricated structure with tank but includes cost of items required for installation of solar panels on top of the tank.Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document. 63 Structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height 64 Design, Fabrication and installation of MS galvanised structure for installation of Solar Penals at a height of 4m above ground level 65 120CM high fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30 cm in ground embedded in cement concrete, 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm angle iron provided with three horizontal lines and two diagonal of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 66 Providing and fixing 1.2 metres high GI barbed wire fencing with 1.8 m angle iron posts 40 mm x 40 mm x 6 mm placed every 3 metres center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 9 horizontal lines and 2 diagonals interwoven with horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 807 of MoRTH specification & type A as per IS : 278-1978 size designation 5 (line wire 2.24, point wire 2.00mm mass 97-106 g/m) includiing all material, labour. 67 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 68 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 69 2.2 KW 70 5.5 KW 71 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer,phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level.The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 72 Up to 5.00 HP 73 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 74 Above5 HPand upto 10 HP 75 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 76 5.5 KW (7.5 HP) & head up to 120 mtr. 77 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 78 3 core 4.0 Sq.mm 79 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 80 10.0 Sq. mm 4 core 81 Providing & Lowering in tube well ISI marked GI Pipe “B class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 82 50 mm dia 83 Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Class PN 1.6 84 100 mm dia 85 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 86 100 mm dia 87 150 mm dia 88 200 mm dia 89 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 90 80 mm dia 91 Providing , lowringlaying , aligninng, fixing in position at all level/ depthC.I. class-B specials as per IS:1538, amended up to date in trench complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical specification and as per direction of Engineer( Note:- E/W to be measured and paid seperately) plain ended CI specials including tail pice, spigot end and socket end. 92 Upto 300mm 93 Providing, lowering, laying, aligning, fixing in positionand jointing at alllevel/depthsDIstandardspecialswithrubberring (EPDM)/ nut bolt and insertion sheet andjointingasperIS:9523- 2000 or as amended up to date,suchastees,bends, tapers,caps etc. within trenchesin DI pipe line completeincluding all material, labour, taxes, testingand commissioningalong with pipe line as per technicalspecificationsanddirectionofEngineer-in-charge (excluding earth work). 94 AII End Flanged 95 Upto 300mm 96 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 97 GSM Modem for SMS Facility- 24 V DC operated for bulk flow meter to transmit reading of flow meter to LCC/MCC Centre 98 Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: - 99 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall.e) Successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab. 100 j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mmp) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 101 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M 102 50 KL, staging Height 15 m 103 75 KL, staging Height 15 m 104 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - 105 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). 106 k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 107 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II18 M Staging 108 100 KL, staging Height 18 m 109 150 KL, staging Height 18 m 110 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II20 M Staging 111 100 KL, staging Height 20 m 112 250 KL, staging Height 22 m (1-Nos.) 113 Providing Household Tap Connectionas per technical specification and approveddrawingasperrelevantIScode(amendeduptodate)from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanicalIntegrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , notexceedingtheflowof7LPMat2barandacompressionelbow, mouldedinsinglepiece(Completejob)includingdiggingoutsuitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specificationforpotablewaterincludingGMFull-wayValve(IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80PN16asperISO4427/20mmnominal diaPPR-C(Three layered) pipe PN16 SDR7.4 (IS:15801:2008)(ISI mark)and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premisesforfixinga tap/ meterbox (excluding),including accessories withflushing,cleaning,disinfectingandtestingofpipelinecomplete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note:Roadcutandrestorationisnotpartofthisitemandpaid separately. 114 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 115 Providing and fixing ISI mark (IS 9763: 2000 or amended upto date) PTMT bib cock 15 moinal bore minimum weight 92 gms and length 100 mm as per technical specification, approved make and direction of Engineer in charge. 116 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 117 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 118 Construction of Tube Well up to 100 mtr. depthin all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe. 119 150 mm dia nominal bore. 120 Nominal bore 200 mm dia. - for 1 No. of Tube Wells for 1st 100 m 121 Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. For 20 m more additional depth (total depth 120m) 122 Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. For 20 m more additional depth (total depth 120m) 123 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 124 200mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 125 200 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) 126 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 127 150 mm dia 128 200 mm dia 129 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. All kinds of soil. 130 Providing and laying in position cement concrete including curing compaction etc . Complete in specified grade excluding the cost of centering and shuttering. All workto plinth level using crusher broken aggregate 131 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 132 M20 Grade nominal mix (with graded stone aggregate 20mmnominal size) 133 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement for Walls (any hickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. 134 M20 grade Nominal Mix / Design Mix 135 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 136 Columns, pillars, posts and struts etc. (Pillar above GL) 137 Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 138 100 mm dia 139 150 mm dia 140 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-incharge.MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) 141 Earth work in excavation over areas (exceeding 30cm depth, 1.5 mtr in width and 10 SQM in plan)for construction of open well, lift up to 1.5 Mtr. including taking out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. 142 From0 m to 1.5 m BGL 143 Ordinary rock 144 From1.5 m to 6 m BGL 145 Hard rock (requiring blasting) usefulmaterial 30 % 146 From6 m to 7 m BGL 147 From6 m to 20 m BGL 148 Add extra over item No 1 for every additional; lift of 1.5 m or part thereof. 149 All Kind Of soilFrom1.5 m to 4.5 m BGL 150 In Ordinary RockFrom4.5 m to 6 m BGL 151 In hard rock 152 From6 m to 7.5 m BGL 153 From7.5 m to 9 m BGL 154 From9 m to 10.5 m BGL 155 From10.5 m to 12 m BGL 156 From12 m to 13.5 m BGL 157 From13.5 m to 15 m BGL 158 From15 m to 16.5 m BGL 159 From16.5 m to 18 m BGL 160 From18 m to 19.5 m BGL 161 From19.5 m to 20 m BGL 162 Add 20% extra over item No. 2.39 for excavation in saturated soil where pumping or baling out of water is required, including shoring strutting where required and dewatering.(Respective applicable rates)From6 m to 18 m BGL 163 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for :Walls (any thickness) including attached pilasters,buttressesplinthandstring course.Add extra for shuttering in circular work in plan up to dia 10m over item Nos. 4.7.1 to 4.7.2 164 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 165 Thermo-mechanically Treated bars (Conforming of relevent IS code) 166 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement. 167 M20 Grade nominal mix (with graded stone aggregate 20mm nominal size) 168 Structural steel work in single section fixed with connecting plate includingcutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height 169 Filling available excavated earth (excluding rock) in trenches plint side of foundation etc. in layers not extending 20cm in depth, consolidating each deposited layer by ramming & watering including lead upto 50m. 170 Labour charges for horizontal boring 100 mm dia in open well in rocky stratawith all types of rock cutting & drilling tools etc. including all T&P required for job including dewatering arrangement. 171 Earth work in excavation over areas (exceeding 30 Cm. In depth, 1.5 Mtr. In width as well as 10 Sqm. on plan) including disposal of excavated earth lead up to 50 M and lift up to 1.5 Mtr. Disposed earth to be leveled and neatly dressed:All kinds of soi 172 Random Rubble stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in 173 In cement mortar 1:4 (1 cement : 4 coarse sand) 174 Brick masonry in partition in super structure up to third storey 7 cm thick (brick on edge) using bricks of class designation 75 in 175 Cement mortar 1:3 (1 cement : 3 coarse sand) 176 Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : 177 1:4 (1 cement : 4 fine/ coarse sand) 178 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishingand reinforcement: 179 M20 (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 180 Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level. 181 Wall (any thickness) including attached pilasters, buttresses, plinth and string course 182 Suspended floors, roofs, landings, balconies and access platform. 183 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete 184 Thermo-Mechanically Treated bars 185 Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Sheesham wood Grade-1 186 Cement concrtete grade 1:2:4 (1 Cement: 2 Coarse sand : 4 graded stone aggregate ) rounding of adeges etc.. but excluding the cost of nosing of steps etc. complete 187 75mm thick with 20mm thick nominal size aggregate 188 P & F IP-65 protected street light luminaire on existing bracket suitable for HPSV/ MH LAMP, made from powder coated single piece pressure die cast aluminium housing, electrochemically brightened and anodized POT optics aluminium reflector, heat resistant and toughened glass cover and accessories like copper ballast, electronic ignitor, capacitor, holder prewired up to terminal block etc. as required including making connection testing etc. as required(without lamp) 189 Street Light Suitable for HPSV Lamps1 X 150 Watt 190 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked( IS:9537 P - II ) rigid steel conduit & its accessories, round tiles,18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board& false ceiling point,6 A switch, 3.0 mm thick ISI markedphenolic laminated sheet, pvc bushes, check nuts, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.Group-III 191 Short point (up to 3 mtr.) 192 Medium point (up to 6 mtr.) 193 Providing and fixing, flush door shutters non decorative type (hollow core construction) with internal frame of Ist grade wood having styles and top rails of 100 mm width & bottom and lock rails of 150 mm width with 3 Nos. cross battens of 50 mm thick width using 4 mm thick commercial ply on both faces of shutters & 6 mm thick beading of respective wood using with approved steel fitting as perAnnexure A :- 194 25 mm thick. 195 Sheesham wood grade – I 196 Wiring of 3 pin 5 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved makein surface / recessed ISI marked ( IS:9537 P - II ) rigid steel conduit & its accessories, 18 SWG 175 mm x 100 mm x 60 mm M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board ,6 Aswitch, 6 A socket, 3.0 mm thick ISI marked phenoliclaminated sheet, pvc bushes, check nuts, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.Group-III 197 Short point (up to 3 mtr.) 198 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 199 4.0 sq.mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
33.
Drinking Water Supply and Sanitation #9180445 Technical Bid
Tender For Work Of Construction Of Tube well, Providing, laying & jointing Of Rising Main Pipelines Internal Village Distribution Pipeline Reservoir Fhtc In Jjm Village Ismailpur Under Ps Kishangarhbas - Work of Construction of Source, PLJ of rising main pipelines, internal village distribution pipeline, Reservoir and FHTC including one-year Defect Liability period of Village Ismailpur under Panchayat Samiti Kishangarhbas under JJM in the jurisdiction of PHED Division Bhiwadi (NCR) Sl. No. Item Description 1 Drilling Work 2 Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe.Nominal bore 200 mm dia. (PHED 2021/2.3.2) 3 Add 15% extra on above itemfor drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. . (PHED 2021/2.3.3) 4 Add 30% extra on above item for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr .(PHED 2021/2.3.4) 5 Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work will include lowering of housingand strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed afterobtaining sand free water.Nominal bore 200 mm dia. (PHED 2021/2.6.3) 6 Add 15% extra on above itemfor drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr . (PHED 2021/2.6.4) 7 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) (PHED 2021/2.11.2) 8 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985 200 mm dia nominal bore. (PHED 2021/2.12.3) 9 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 mm. dia.(PHED 2021/2.23.3) 10 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. (PHED 2021/2.15) 11 11 KW (15 HP) & head above 120 mtr. (2.15.8) 12 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc.(PHED 2021/2.19) 13 3 core 6.0 Sq.mm (2.19.2) 14 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 16.0 Sq.mm, 4 core.(PHED 2021/2.20.2) 15 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. (PHED 2021/2.24) 16 50 mm dia (2.24.2) 17 Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casing pipe for submersible cable external work 40 mm dia complete in all respect. (PHED 2021/2.13) 18 Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes80mm Dia (PHED 2021/2.30.2) 19 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. (PHED 2021/2.32) 20 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of 80 mm dia (PHED 2021/ 2.26.3) 21 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.. (PHED 2021/ 2.18) 22 above 10.0 HP and up to 15.0 HP (2.18.2) 23 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.(PHED 2021/2.21) 24 Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. (PHED 2021/2.27) 25 Providing and fixing G.I. pipes complete with G.I.fittings including trenching and refilling etc. External work : 80 mm dia. nominal bore (RUIDP2017/34.12.8) 26 RISING, DISTRIBUTION PIPELINE,& CIVIL WORK 27 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80PN-10 (PHED 2021/1.4.3) 28 90 mm dia(1.4.3.1) 29 110 mm dia (1.4.3.2) 30 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M.HDPE PE-80PN-10 (PHED 2021/1.5.3) 31 125mm dia(1.5.3.1 ) 32 160 mm dia (1.5.3.3 ) 33 200mm dia (1.5.3.5 ) 34 Construction of RCC valve chamber for different type of valves including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & cover slab all 125mm thick with C.I. surface box with hinged cover 100x100x75mm (deep), including cost of steelreinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. (RUIDP 2017/19.59) 35 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve ( 19.59.1 ) 36 90cm x 90cm x 100cm (depth) for 200/250/300 mm dia valve ( 19.59.2 ) 37 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80PN-6 (PHED 2021/1.4.1) 38 75 mm dia( 1.4.1.1 ) 39 90 mm dia ( 1.4.1.2 ) 40 110 mm dia ( 1.4.1.3 ) 41 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M.HDPE PE-80PN-6 (PHED 2021/1.5.1) 42 125mm dia ( 1.5.1.1 ) 43 140 mm dia ( 1.5.1.2 ) 44 160 mm dia ( 1.5.1.3 ) 45 200mm dia ( 1.5.1.5 ) 46 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated CI Sluice valve of Class PN-1.0 (PHED 2021/6.1.1) 47 80 mm HW (6.1.1.1 ) 48 125 mm HW (6.1.1.3 ) 49 100 mm HW (6.1.1.2 ) 50 150 mm HW (6.1.1.4 ) 51 200 mm HW (6.1.1.5 ) 52 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil.(PHED 2021/4.1 53 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. (PHED 2021/4.5) 54 Removing& Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technical specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)(PHED 2021/4.9) 55 80mm Thick (4.9.2) 56 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).(PHED 2021/4.8.1) 57 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. (PHED 2021/4.7) 58 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. 1:4:8 ( 1 cement : 4 coares sand : 8 graded stone aggregate 40mm nominal size) (PWD BSR 2019 / B-3/3.1.6) 59 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). (PWD BSR 2019 /B-6.1.6) 60 Plaster on new surface on walls in cementsandmortar1:4including rackingofjointsetc.complete fine finish : (20 mm thick) (PWD BSR 2019 /B_12.2.2) 61 Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointingwith cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects : (PWD BSR 2019 /B-11/11.20) 62 S&F RCC Manholes covers with frame of approved make (Light duty) Size 600x600mm Double seal (PWD/2019/S-3/3.35.4) 63 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. MS pipespecialsupto600mmdia (withminimum5mmthickness sheet)(PHED 2021/1.11.1 ) 64 Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. (PHED 2021/1.22 ) 65 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. (1.22.1) 66 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. (PHED 2021 / 1.26) 67 P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. (PHED 2021/1.23) 68 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge. (PHED 2021/1.25) 69 Providing and fixing steel gate, grating, and grills made of angles, tees, square bars, flats or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide (PWD BSR 2019/ B41-9.8.1) 70 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: two or more coats on old work (PWD BSR 2019/ B73-12.48.1) 71 Lettering with black japan paint of approved brand andmanufacture (PWD BSR 2019/ B76-12.64) 72 Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 (PHED2021/3.3.1) 73 150KL capacity ( 3.3.1.4 ) 74 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.(PHED 2021/5.5) 75 11.0 KW (15 HP)(5.5.6) 76 15.0 KW (20.0 HP)(5.5.7) 77 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 35.0 Sq.mm, 3.5 core ( PHED 2021/2.20.4 ) 78 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 3 core 10.0 Sq.mm (PHED 2020/2.19.3) 79 SITC STAR DELTA Starter type LT Panel of followingrating:all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Baklight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Netural Links , Sprial , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminum Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. (PHED 2021/ 7.2) 80 STAR DELTA STARTER15.0 KW (20.0 HP) :For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)and O/G-MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) (PHED 2021/ 7.2.4) 81 Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 100 mm dia (PHED 2021/3.6.4) 82 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c)OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e)Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container.i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.( PHED2021 /3.2 ) 83 400 KL capacityRCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 20 M (3.2.15.6) 84 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. ( PHED2021/3.7 ) 85 100 mm (3.7.1) 86 150 mm (3.7.2) 87 200 mm (3.7.3) 88 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work.( PHED 2021/11.3 ) 89 BFM 150 mm 90 BFM 200 mm 91 Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.( PHED/2021/8.1 ) 92 120cm. high fencing with angle ironposts50x50x6mm.placedat every 3 Mtr. apart 30cm. in ground embeddedincementconcrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with three horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staple including earth work in excavation etc. complete. ( PWD Alwar 2019 / B_9.31 ) 93 Providingandfixingcowcatcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with primingcoatofredoxide(asper design). ( PWD Alwar 2019 / B_9.9 ) 94 Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints.( PHED 2021/8.30 ) 95 Brick work with F.P.S bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in: cement morter 1:4(1 cement :4 coarse sand) ( PWD Alwar 2019 / B_5.2.1 ) 96 E/W in excavationby mechanical means (hydraulic excavator/manual means over area (exceeding 30 cm in depth,1.5 mtr in width as well as 10 sqm on plan including disposal of excavated earth lead up to 1.5 mtr. Disposed earth earth to be leveled and neatly dressed all kind of soil ( PWD2019/B1/1.6 ) 97 Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm Dia ( PWD2019/S4/4.24.1 ) 98 Supply & fixing Pre cast RCC ring at mouth of recharge shaft of M20 mix with 40 mm thickness 900mm dia ( PWD2019/S4/4.25.1 ) 99 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. ( PWD2019/B-4 /4.9 ) 100 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.hot rolled deformed bar (IS:1139) ( PWD2019/B-4 /4.13.2 ) 101 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix ( PWD2019/B-4 /4.1 ) 102 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). ( PWD2019/S4/3.1.2 ) 103 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids 104 Size 9 to 12 mm ( PWD2019/S4/4.28.1 ) 105 Size 3 to 5 mm( PWD2019/S4/4.28.2 ) 106 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids.( PWD2019/S4/4.29 )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
34.
Drinking Water Supply and Sanitation #9156918 Technical Bid
tender for Work for construction of 200mm dia tubewell, RCC Reservoirs, Pipeline, FHTC and other allied works at RWSS Bhoodiyabas-Barhdoli in JJM under PHED Sub Division Thanagaji Including Defect Liability Period in the jurisdiction of phed Rural Dn.2 NCR Alwar (Based on PHED BSR 2020) Sl. No. Item Description 1 Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipein all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: 2800(Part I:1991 and IS:2800 part II :1979 as (both amended up to date ). The work will include lowering of housing pipe and strainer pipe assembly and casing shoe but incuding cost of casing shoe but excluding cost of the casing pipe. The work would be completed after obtaining sand free water. 2 Nominal bore 200mm dia 3 Construction of tube well after completion of drilling by rotary /percussion/odex method & upto 150 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. 4 (a) Up to 150 Mtr. 5 (b) Above 150 Mtr. 6 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date ofsize 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)(a) 200 MMDia 7 Labourcharges for making slots on blank pipes made of ERW MS black pipe ISI marked of following size, the slotting should be as per IS: 8110-1985. (a) 200 MM dia nominal bore of 5.4 mm thickness 8 Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5 mm thick 100 mm wide shroud around the edge so as to form a cap on the topend of casing pipe with GI Nipple 45cm long & two GI flanges at bothend in 80mm sizes passing through a hole in the centre of MS sheet. A25mm socket with end plug shall also be welded over top plate (as perdrawillg enclosed). A GI nipple having outside thread of size 1/2 (forinstallation pressure gauge) shall tie provided & welded with 80mm GInipple near top plate nipple shall be provided with end plug.(a) 200 MM Dia 9 Supply, installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283- 2013 (motor) or amended upto date of approved make of following duty condition with required accessories includig making connection suitable for tube well/ DCB. The job includes lowering of motor pumps, installation of complete fitting & accessories, jointing of electrical cables upto switch board, testing of submersible pump sets and interconnection up to water mains, complete in all respect.(a) 9.3 KW (12.5 HP) & Head above 120 Mtr. 10 Supply & fixing of ISI marked three core PVC flat submersible cable as per IS : 694:1990 ro amended upto date and conductor as per class 5 of IS 8130:1980 including making connection etc.(a) 3 core 4.00 Sq. MM 11 Providing & Lowering in tubewell ISI marked GI Pipe B class as per IS: 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25 x 3 mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.(a) 50 MM Dia 12 (b) 80mm dia 13 Providing and layingof GI pipe of A (light) class IS:1239 part I 2004 or amended up to date for casing pipe for submercible cable exeternal/internal work 40 mm dia complete in all respect. 14 Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.(a) 4 core 16.00 Sq. MM 15 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Class PN 1.0 (80mm dia) 16 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually operated CI sluice valve of class PN-1.0 (80mm HW) 17 Plate Earthing as per IS: 3043 with G.I Earth plate of size 600mm X 600mm X 6.00mm by embodying 3 to 4mtr. below the ground level with 20mm Dia G.I B class watering pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel and C.C finished chamber covered with hinged type with locking arrangement C.I Cover, C.I frame of SIze 300mm X 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 18 Providing, installing, testing and commissioning of double flanged bulkflow meter with removable mechanism, of class B conforming to ISO406411 or amended upto date of approved make including cost of all material and labour as per specifications with G I Box (sheet 16 SWG) suitable with locking arrangement of 65mm dia 19 Supply and Fixing ofelectric control feeder panel comprising ofsuitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy mete r (supplied by DI SCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each legs length 18 and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening ofsuitable size in front ofspace for energy mete r with glass for meter reading. T he o peration of panel should be suitable for on 440 Volt AC Supply(a) above 10 HP and Up to 15 HP 20 Providing &fixing of pump safety cage as per specification as directed by Engineer. 21 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines,shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete forlifts up to 1.5 depth and strata as specified. The work also includesdepositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. 22 in all type of soil 23 For HDPE pipeline dia up to 110mm 24 For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. 25 For dia of pipe above 150 mm and up to 350 mm nominal. 26 Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified,complete work as per technical specification and scope of work. 27 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. 28 M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coares sand : 4 graded stone aggregate 20mm nominal size). 29 Dismantling of cement concrete pavement for pipe lineand chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 30 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 31 (HDPE PE-80 PN-6) 32 75mm 33 90mm 34 110mm 35 (HDPE PE-80 PN-10) 36 90mm 37 110mm 38 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 39 (HDPE PE-80 PN-6) 40 125mm 41 160mm 42 (HDPE PE-80 PN-10) 43 125mm 44 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendeduptodate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 45 80mm 46 100mm 47 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 48 Manually Operated CI Sluice valve of Class PN-1.0 49 80 mm HW 50 100 mm HW 51 125 mm HW 52 150 mm HW 53 Removing& Re-fixing of Precast concrete interlocking blocks by manual, stacking of severciable & un serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block, alllead and lift as per general specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) 54 60mm Thick 55 Construction of RCC valve chamber for different type of valves including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & cover slab all 125mm thick with C.I. surface box with hinged cover 100x100x75mm (deep), including cost of steelreinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. 56 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve 57 Providing service connection as per technical specification and standard drawing as per relevant IS code (amended up to date) from all kind of water mains up to consumer meter/premises (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil including demolishing of cement concrete,WBM, Black top etc. of all thickness; cutting of CC road/jhiri by using a concrete cutter machine; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 50 meter ; providing & fixing of all fitting duly approved in accordance with ISO/DTR 9080 as per specification for potable water including approved make of MS/PVC clamp with saddle piece, gunmetal ferrule 4.0 mm (ISI make) ,valve (IS: 778) and specials with MDPE pipe PE80 PN 12.5 as per ISO 4427 below ground level and GI 15 mm class B (ISI mark) above ground level ( max. length 3.0 mtr), P&F a Bib Cock (IS : 8931 Mark), Superior quality Brass 400 gm,15 mm nominal bore including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . In addition to the ferrule, an orifice of 4.0 mm dia should also be provided in the service line at the entry point of the consumers property in such a way that it should be accessible for inspection to VWSC, PHED and any other authority which would like to inspect as and when required. The service line should be laid at least 45 cm below ground level, except in case of concrete/bituminous roads where minimum depth shall be 20 cm.For detailed specifications of MDPE pipes please refer section Technical Specifications of bid document. General specifications of MDPE pipes shall be as under:• The raw material shall be virgin PE 80 Blue compound and comply with the requirements of ISO/Directive of testing material : 9080 with minimum required strength of 8 Kg/sq.cm.• The raw material shall be Food grade quality Pressure rating shall be 12.5 Bar.• The pipes shall bear ISO marking. 58 Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm GI class B pipe 59 Extra length of 20 mm MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 60 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). 61 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee. 62 12.5HP 63 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 64 3 core 6.0 Sq.mm 65 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.25.0 Sq.mm, 3.5 core 66 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for440 Volt AC Supply. 67 Above 10 to 15 HP 68 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.(80mm dia) 69 Providing and fixing G.I. pipes complete with G.I.fittings including trenching and refilling etc. External work : 80 mm dia. nominal bore 70 Construction of RCC Clear Water Reservoirsof required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab and food grade epoxy paint to inner face of the container and slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar,ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints on all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. 71 The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete. 72 Below mentioned rates are for raft foundations with soil bearing capacity (SBC) of 10 MT/sqm and applicable for SBC more than or equal to 10MT/sqm and less than 18MT/sqm. These rates shall be increased or decreased for variation in SBC as below: 73 i) Forfoundation onSBC 7 MT/sqmapplicable for SBC more than or equal to 7 MT/sqm and less than 10 MT/sqm, add 5%ii) Forfoundation on SBC more than 5 MT/sqm and up to 7 MT/sqm, add 7.5%. iii) For foundation on SBC more than 18MT/sqm rates decreased by 5 % 74 Following rates are for seismic zone II. For zone III, these rates shall be increased by 4% and for zone IV, these rates shall be increased by 9%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones. 75 Rates for RCC Circular Flat Slab CWR, SBC 10T/sqm, seismic zone II (Capacity 75KL) 76 Add 4% for seismic zone III 77 Construction of RCC INTZE type Head Service Reservoir of following capacityand staging consisting of excavation in all types of strata, RCC work, cement plaster with water proofing compound to the inner face of the container including refilling disposing off the surplus stuff, plinth protection , all labour and material charges includingproviding and fixing of accessories such as ladder , manhole frame and covers, water level indicator (float type), ventilator with SS screen, lightening arrestor, float valve, puddle collar, G.I. pipe railing around walk way and top dome, providing RCC staircase from 4.5 mtr height ofground level to top level, chambers for all valves, providing and applying three coats ofcement paintto the external surfaces of container, column, bracing, carbonation paint on external surface of top dome,food grade epoxy paint on internal surface and giving satisfactory hydraulic test and water tightnesstest as per I.S. code, etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job includes conducting SBC test, design and proof check of reservoirs (if required),painting the name of the scheme and other details on the reservoir, providing alluminium portable ladder suitable to reach at height of 4.5 Mtr(start of RCC reservoir) and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work . 78 The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete. 79 Below mentioned rates are for raft foundations with soil bearing capacity (SBC) of 10 MT/sqm and applicable for SBC more than or equal to 10MT/sqm and less than 18MT/sqm. These rates shall be increased or decreased for variation in SBC as below: 80 i) Forfoundation onSBC 7 MT/sqmapplicable for SBC more than or equal to 7 MT/sqm and less than 10 MT/sqm, add 5%ii) Forfoundation on SBC more than 5 MT/sqm and up to 7 MT/sqm, add 7.5%.iii) For foundation on SBC more than 18MT/sqm rates decreased by 5 %iv) For foundation on SBC more than 10MT/sqm rates decreased by 5 %v) The rates are applicable for staging height of 18 M. These rates shall be increased or decreased for variation in the staging height as belowvi) For staging 20 Mtr add 5%vii) For staging 22 Mtr add 7%viii) For staging above 22 Mtr add 2% per mtr over rate of 22 mtr staging ( only in exceptional condition where hydraulics does not permit)ix) For staging less than 18 Mtr decrease 2% per Mtr. 81 Following rates are for seismic zone II. For zone III, these rates shall be increased by 4% and for zone IV, these rates shall be increased by 9%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones. 82 Rates for RCC OHSR, SBC 10T/sqm, seismic zone II 18mtr(Capacity 250KL) 83 Add 4% for seismic zone III 84 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 85 100 MM Dia 86 150 MM Dia 87 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 88 BFM 100MM 89 BFM 150MM 90 E/W in excavationby mechanical means (hydraulic excavator/manual means over area (exceeding 30 cm in depth,1.5 mtr in width as well as 10 sqm on plan including disposal of excavated earth lead up to 1.5 mtr. Disposed earth earth to be leveled and neatly dressed all kind of soil 91 All kind of soil 92 Ordinary rock 93 Providing and laying in position cement concrete including curing compaction etc complete in specified grade excluding the cost of centring and shuttering all work up to plinth level 94 1:4:8 aggregate 40mm nominal size 95 1:2:4 aggregate 20mm nominal size 96 Structural steel work in single section fixed without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primar all complete above plinth level upto 4.5 mtr height 97 Supply of coase sand 98 Providing and fixing gravels 99 6 mm nominal size crusher broken 100 20mm nominal size crusher broken 101 100mm hand broken 102 300mm hand broken 103 Plaster on New surface on wall in cement sand mortar 1:3 including raking of joints etc complete 104 Providing & fixing wire mesh 14 mesh x 24.0 gauze 105 Random rubble dry stone kharanja under floor 106 Providing & lowring of ISI mark unplastisized ployvinyl chloride (PVC-U) casing pipe as per IS:12818:2010 or amended upto date and technical specification for tubewell or DCB with threading winding with superior quality of plastic meh and rope in three layers with end cap complete. 107 150mm nominal bore 108 Stone masonary for foundation random rubble stone masonary for with hard stone in foundation and plinth in cement sand mortar above 30cm thick wall i cement sand mortar 1:6
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
35.
Railways #9116991 AOC
Supply Of Kit For Jointing [Btpn] Consisting Of 03 Items. 1] Gland Ring For 100 Mm Lubricated Taper Plug Valve To Rdso Drg. No. Wd-93066-S-07 Alt.-1, Qty.-30 Nos. 2] Gasket For 100 Mm Lubricated Taper Plug Valve To Rdso Drg. No. Wd-93066-S-04 Alt.-1, Qty.-05 Nos. 3] Gland Packing For 100 Mm Lubricated Taper Plug Valve To Rdso Drg. No. Wd-93066-S-08 Alt.-1, Qty.-30 Nos. Material And Specification For Gland Ring And Gasket Should Be To Is 2712 : 2024, Gr O/2. Material And Specification For Gland Packing Should Be To Is 4687 : 1995 (Ra-2022), Gr Type-2. Note: 1 Set Consists Of 65 Nos. These Components Must Be Suitable And Match With All Makes Of Taper Plug Valve 100 Mm Supplied By Rdso Approved Vendors.Kit For Jointing [Btpn] Consisting Of 03 Items. 1] Gland Ring For 100 Mm Lubricated Taper Plug Valve To Rdso Drg. No. Wd-93066-S-07 Alt.-1, Qty.-30 Nos. 2] Gasket For 100 Mm Lubricated Taper Plug Valve To Rdso Drg. No. Wd-93066-S-04 Alt.-1, Qty.-05 Nos. 3] Gland Packing For 100 Mm Lubricated Taper Plug Valve To Rdso Drg. No. Wd-93066-S-08 Alt.-1, Qty.-30 Nos. Material And Specification For Gland Ring And Gasket Should Be To Is 2712 : 2024, Gr O/2. Material And Specification For Gland Packing Should Be To Is 4687 : 1995 (Ra-2022), Gr Type-2. Note: 1 Set Consists Of 65 Nos. These Components Must Be Suitable And Match With All Makes Of Taper Plug Valve 100 Mm Supplied By Rdso Approved Vendors.,Kit For Jointing [Btpn] Consisiting 03 Items. [1]Gland Ring 100 Mm Qty. In Kit. 3 0 Nos. Drg. No. Wd-93066-S-07, Alt-1. [2]Gasket For 100 Mm Qty. In Kit 05 Nos. Drg. No. Wd-93 066-S-04, Alt- 1. [3]Gland Packing For 100 Mm Taper Plug, Qty In Kit 30 Nos. Drg. No. Wd-9306 6-S-08, Alt-1. Material And Specn As Per Drg. 1 Set Consists Of 65 Nos. This Item Is Reserved For Procurement From Rdso Approved Sources Only. [ Warranty Period: 30 Months After Th E Date Of Delivery ] [Quantity Tolerance (+/-): 5 %Age , Item Category : Normal , Total Po Value Variation Permitt Ed: Max 8 Lacs ] ] Smm-D(Wagon), Bhusawal, Maharashtra 60.00 Set
Contract Date: Feb 02, 2026 Contract Value : 10,148
Government Departments No of Bidders 1
Maharashtra View Result →
36.
Drinking Water Supply and Sanitation #9115317 Technical Bid
Tender For Work for construction of 200mm dia tubewell, RCC Reservoirs, Pipeline, FHTC and other allied works at RWSS Malutanain JJM under PHED Sub Division Thanagaji Including Defect Liability Period in the jurisdiction of phed Rural Dn.2 NCR Alwar Sl. No. Item Description 1 Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipein all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: 2800(Part I:1991 and IS:2800 part II :1979 as (both amended up to date ). The work will include lowering of housing pipe and strainer pipe assembly and casing shoe but incuding cost of casing shoe but excluding cost of the casing pipe. The work would be completed after obtaining sand free water. 2 Nominal bore 200mm dia 3 Construction of tube well after completion of drilling by rotary /percussion/odex method & upto 150 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. 4 (a) Up to 150 Mtr. 5 (b) Above 150 Mtr. 6 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date ofsize 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)(a) 200 MMDia 7 Labourcharges for making slots on blank pipes made of ERW MS black pipe ISI marked of following size, the slotting should be as per IS: 8110-1985. (a) 200 MM dia nominal bore of 5.4 mm thickness 8 Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5 mm thick 100 mm wide shroud around the edge so as to form a cap on the topend of casing pipe with GI Nipple 45cm long & two GI flanges at bothend in 80mm sizes passing through a hole in the centre of MS sheet. A25mm socket with end plug shall also be welded over top plate (as perdrawillg enclosed). A GI nipple having outside thread of size 1/2 (forinstallation pressure gauge) shall tie provided & welded with 80mm GInipple near top plate nipple shall be provided with end plug.(a) 200 MM Dia 9 Supply, installation of 3 phase ISI marked submersible motor pump set of five star rating by BEE and as per IS: 8034-2018 (pump) and IS 9283- 2013 (motor) or amended upto date of approved make of following duty condition with required accessories includig making connection suitable for tube well/ DCB. The job includes lowering of motor pumps, installation of complete fitting & accessories, jointing of electrical cables upto switch board, testing of submersible pump sets and interconnection up to water mains, complete in all respect.(a) 9.3 KW (12.5 HP) & Head above 120 Mtr. 10 Supply & fixing of ISI marked three core PVC flat submersible cable as per IS : 694:1990 ro amended upto date and conductor as per class 5 of IS 8130:1980 including making connection etc.(a) 3 core 4.00 Sq. MM 11 Providing & Lowering in tubewell ISI marked GI Pipe B class as per IS: 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25 x 3 mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.(a) 50 MM Dia 12 (b) 80mm dia 13 Providing and layingof GI pipe of A (light) class IS:1239 part I 2004 or amended up to date for casing pipe for submercible cable exeternal/internal work 40 mm dia complete in all respect. 14 Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.(a) 4 core 16.00 Sq. MM 15 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Class PN 1.0 (80mm dia) 16 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually operated CI sluice valve of class PN-1.0 (80mm HW) 17 Plate Earthing as per IS: 3043 with G.I Earth plate of size 600mm X 600mm X 6.00mm by embodying 3 to 4mtr. below the ground level with 20mm Dia G.I B class watering pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel and C.C finished chamber covered with hinged type with locking arrangement C.I Cover, C.I frame of SIze 300mm X 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 18 Providing, installing, testing and commissioning of double flanged bulkflow meter with removable mechanism, of class B conforming to ISO406411 or amended upto date of approved make including cost of all material and labour as per specifications with G I Box (sheet 16 SWG) suitable with locking arrangement of 65mm dia 19 Supply and Fixing ofelectric control feeder panel comprising ofsuitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy mete r (supplied by DI SCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each legs length 18 and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening ofsuitable size in front ofspace for energy mete r with glass for meter reading. T he o peration of panel should be suitable for on 440 Volt AC Supply(a) above 10 HP and Up to 15 HP 20 Providing &fixing of pump safety cage as per specification as directed by Engineer. 21 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines,shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete forlifts up to 1.5 depth and strata as specified. The work also includesdepositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. 22 in all type of soil 23 For HDPE pipeline dia up to 110mm 24 For dia of pipe up to 150 mm nominal, for HDPE pipe dia above 110 & up to 140 mm. 25 Providing and laying in position cement concrete 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified,complete work as per technical specification and scope of work. 26 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. 27 M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coares sand : 4 graded stone aggregate 20mm nominal size). 28 Dismantling of cement concrete pavement for pipe lineand chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 29 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 30 (HDPE PE-80 PN-6) 31 75mm 32 90mm 33 110mm 34 (HDPE PE-80 PN-10) 35 90mm 36 110mm 37 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 38 (HDPE PE-80 PN-6) 39 125mm 40 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendeduptodate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 41 80mm 42 100mm 43 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 44 Manually Operated CI Sluice valve of Class PN-1.0 45 80 mm HW 46 100 mm HW 47 125 mm HW 48 150 mm HW 49 Removing& Re-fixing of Precast concrete interlocking blocks by manual, stacking of severciable & un serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block, alllead and lift as per general specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) 50 60mm Thick 51 Construction of RCC valve chamber for different type of valves including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & cover slab all 125mm thick with C.I. surface box with hinged cover 100x100x75mm (deep), including cost of steelreinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. 52 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve 53 Providing service connection as per technical specification and standard drawing as per relevant IS code (amended up to date) from all kind of water mains up to consumer meter/premises (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil including demolishing of cement concrete,WBM, Black top etc. of all thickness; cutting of CC road/jhiri by using a concrete cutter machine; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 50 meter ; providing & fixing of all fitting duly approved in accordance with ISO/DTR 9080 as per specification for potable water including approved make of MS/PVC clamp with saddle piece, gunmetal ferrule 4.0 mm (ISI make) ,valve (IS: 778) and specials with MDPE pipe PE80 PN 12.5 as per ISO 4427 below ground level and GI 15 mm class B (ISI mark) above ground level ( max. length 3.0 mtr), P&F a Bib Cock (IS : 8931 Mark), Superior quality Brass 400 gm,15 mm nominal bore including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . In addition to the ferrule, an orifice of 4.0 mm dia should also be provided in the service line at the entry point of the consumers property in such a way that it should be accessible for inspection to VWSC, PHED and any other authority which would like to inspect as and when required. The service line should be laid at least 45 cm below ground level, except in case of concrete/bituminous roads where minimum depth shall be 20 cm.For detailed specifications of MDPE pipes please refer section Technical Specifications of bid document. General specifications of MDPE pipes shall be as under:• The raw material shall be virgin PE 80 Blue compound and comply with the requirements of ISO/Directive of testing material : 9080 with minimum required strength of 8 Kg/sq.cm.• The raw material shall be Food grade quality Pressure rating shall be 12.5 Bar.• The pipes shall bear ISO marking. 54 Average length up to 05 mtr 20 mm dia MDPE pipe/ 15 mm GI class B pipe 55 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee. 56 10HP 57 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 58 3 core 6.0 Sq.mm 59 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.25.0 Sq.mm, 3.5 core 60 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for440 Volt AC Supply. 61 5 to 10 HP 62 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.(80mm dia) 63 Providing and fixing G.I. pipes complete with G.I.fittings including trenching and refilling etc. External work : 80 mm dia. nominal bore 64 Construction of RCC Clear Water Reservoirsof required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab and food grade epoxy paint to inner face of the container and slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar,ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints on all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. 65 The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete. 66 Below mentioned rates are for raft foundations with soil bearing capacity (SBC) of 10 MT/sqm and applicable for SBC more than or equal to 10MT/sqm and less than 18MT/sqm. These rates shall be increased or decreased for variation in SBC as below: 67 i) Forfoundation onSBC 7 MT/sqmapplicable for SBC more than or equal to 7 MT/sqm and less than 10 MT/sqm, add 5%ii) Forfoundation on SBC more than 5 MT/sqm and up to 7 MT/sqm, add 7.5%. iii) For foundation on SBC more than 18MT/sqm rates decreased by 5 % 68 Following rates are for seismic zone II. For zone III, these rates shall be increased by 4% and for zone IV, these rates shall be increased by 9%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones. 69 Rates for RCC Circular Flat Slab CWR, SBC 10T/sqm, seismic zone II (Capacity 50KL) 70 Add 4% for seismic zone III 71 Construction of RCC INTZE type Head Service Reservoir of following capacityand staging consisting of excavation in all types of strata, RCC work, cement plaster with water proofing compound to the inner face of the container including refilling disposing off the surplus stuff, plinth protection , all labour and material charges includingproviding and fixing of accessories such as ladder , manhole frame and covers, water level indicator (float type), ventilator with SS screen, lightening arrestor, float valve, puddle collar, G.I. pipe railing around walk way and top dome, providing RCC staircase from 4.5 mtr height ofground level to top level, chambers for all valves, providing and applying three coats ofcement paintto the external surfaces of container, column, bracing, carbonation paint on external surface of top dome,food grade epoxy paint on internal surface and giving satisfactory hydraulic test and water tightnesstest as per I.S. code, etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job includes conducting SBC test, design and proof check of reservoirs (if required),painting the name of the scheme and other details on the reservoir, providing alluminium portable ladder suitable to reach at height of 4.5 Mtr(start of RCC reservoir) and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work . 72 The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete. 73 Below mentioned rates are for raft foundations with soil bearing capacity (SBC) of 10 MT/sqm and applicable for SBC more than or equal to 10MT/sqm and less than 18MT/sqm. These rates shall be increased or decreased for variation in SBC as below: 74 i) Forfoundation onSBC 7 MT/sqmapplicable for SBC more than or equal to 7 MT/sqm and less than 10 MT/sqm, add 5%ii) Forfoundation on SBC more than 5 MT/sqm and up to 7 MT/sqm, add 7.5%.iii) For foundation on SBC more than 18MT/sqm rates decreased by 5 %iv) For foundation on SBC more than 10MT/sqm rates decreased by 5 %v) The rates are applicable for staging height of 18 M. These rates shall be increased or decreased for variation in the staging height as belowvi) For staging 20 Mtr add 5%vii) For staging 22 Mtr add 7%viii) For staging above 22 Mtr add 2% per mtr over rate of 22 mtr staging ( only in exceptional condition where hydraulics does not permit)ix) For staging less than 18 Mtr decrease 2% per Mtr. 75 Following rates are for seismic zone II. For zone III, these rates shall be increased by 4% and for zone IV, these rates shall be increased by 9%. Concerned Executive Engineer shall confirm the seismic zone for the scheme from seismic zones plan before estimation and adopt appropriate rates as per actual seismic zones. 76 Rates for RCC OHSR, SBC 10T/sqm, seismic zone II 18mtr(Capacity 200KL) 77 Add 4% for seismic zone III 78 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 79 100 MM Dia 80 150 MM Dia 81 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 82 BFM 100MM 83 BFM 150MM 84 E/W in excavationby mechanical means (hydraulic excavator/manual means over area (exceeding 30 cm in depth,1.5 mtr in width as well as 10 sqm on plan including disposal of excavated earth lead up to 1.5 mtr. Disposed earth earth to be leveled and neatly dressed all kind of soil 85 All kind of soil 86 Ordinary rock 87 Providing and laying in position cement concrete including curing compaction etc complete in specified grade excluding the cost of centring and shuttering all work up to plinth level 88 1:4:8 aggregate 40mm nominal size 89 1:2:4 aggregate 20mm nominal size 90 Structural steel work in single section fixed without connecting plate including cutting hoisting fixing in position and applying a priming coat of approved steel primar all complete above plinth level upto 4.5 mtr height 91 Supply of coase sand 92 Providing and fixing gravels 93 6 mm nominal size crusher broken 94 20mm nominal size crusher broken 95 100mm hand broken 96 300mm hand broken 97 Plaster on New surface on wall in cement sand mortar 1:3 including raking of joints etc complete 98 Providing & fixing wire mesh 14 mesh x 24.0 gauze 99 Random rubble dry stone kharanja under floor 100 Providing & lowring of ISI mark unplastisized ployvinyl chloride (PVC-U) casing pipe as per IS:12818:2010 or amended upto date and technical specification for tubewell or DCB with threading winding with superior quality of plastic meh and rope in three layers with end cap complete. 101 150mm nominal bore 102 Stone masonary for foundation random rubble stone masonary for with hard stone in foundation and plinth in cement sand mortar above 30cm thick wall i cement sand mortar 1:6
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
37.
Drinking Water Supply and Sanitation #9107327 Technical Bid
Tender For Balance Work Jjm Scheme Khedi Ps Kotkasim (On Risk And Cost) -- Balance Work of construction of Sources, rising main pipelines, internal village distribution pipeline and FHTC including one year Defect Liability period of Village Kheri under Panchayat Samiti Kotkasim under JJM in the jurisdiction of PHED Division Bhiwadi ( NCR ) On Risk & Cost Sl. No. Item Description 1 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 mm. dia.(PHED 2021/2.23.3) 2 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. (PHED 2021/2.15) 3 9.3KW (12.5 HP) & head above 120 mtr. (2.15.6) 4 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc.(PHED 2021/2.19) 5 3 core 6.0 Sq.mm (2.19.2) 6 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 16.0 Sq.mm, 4 core.(PHED 2021/2.20.2) 7 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. (PHED 2021/2.24) 8 50 mm dia (2.24.2) 9 Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casing pipe for submersible cable external work 40 mm dia complete in all respect. (PHED 2021/2.13) 10 Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes80mm Dia (PHED 2021/2.30.2) 11 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. (PHED 2021/2.32) 12 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of 80 mm dia (PHED 2021/ 2.26.3) 13 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.. (PHED 2021/ 2.18) 14 above 10.0 HP and up to 15.0 HP (2.18.2) 15 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.(PHED 2021/2.21) 16 Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. (PHED 2021/2.27) 17 Providing and fixing G.I. pipes complete with G.I.fittings including trenching and refilling etc. External work : 80 mm dia. nominal bore (RUIDP2017/34.12.8) 18 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80PN-10 (PHED 2021/1.4.3) 19 90 mm dia(1.4.3.1) 20 Construction of RCC valve chamber for different type of valves including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & cover slab all 125mm thick with C.I. surface box with hinged cover 100x100x75mm (deep), including cost of steelreinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. (RUIDP 2017/19.59) 21 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve ( 19.59.1 ) 22 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80PN-6 (PHED 2021/1.4.1) 23 75 mm dia( 1.4.1.1 ) 24 90 mm dia ( 1.4.1.2 ) 25 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M.HDPE PE-80PN-10 (PHED 2021/1.5.1) 26 125mm dia ( 1.5.1.1 ) 27 140 mm dia ( 1.5.1.2 ) 28 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated CI Sluice valve of Class PN-1.0 (PHED 2021/6.1.1) 29 80 mm HW (6.1.1.1 ) 30 100 mm HW (6.1.1.2 ) 31 125 mm HW (6.1.1.3 ) 32 150 mm HW(6.1.1.4) 33 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil.(PHED 2021/4.1 34 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. (PHED 2021/4.5) 35 Removing& Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technical specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)(PHED 2021/4.9) 36 80mm Thick (4.9.2) 37 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).(PHED 2021/4.8.1) 38 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. (PHED 2021/4.7) 39 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. 1:4:8 ( 1 cement : 4 coares sand : 8 graded stone aggregate 40mm nominal size) (PWD BSR 2019 / B-3/3.1.6) 40 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). (PWD BSR 2019 /B-6.1.6) 41 Plaster on new surface on walls in cementsandmortar1:4including rackingofjointsetc.complete fine finish : (20 mm thick) (PWD BSR 2019 /B_12.2.2) 42 Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointingwith cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects : (PWD BSR 2019 /B-11/11.20) 43 S&F RCC Manholes covers with frame of approved make (Light duty) Size 600x600mm Double seal (PWD/2019/S-3/3.35.4) 44 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. (PHED 2021/4.11 ) 45 300 mm Dia 8 mm thick casing pipe. (4.11.1) 46 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. MS pipespecialsupto600mmdia (withminimum5mmthickness sheet)(PHED 2021/1.11.1 ) 47 Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. (PHED 2021/1.22 ) 48 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. (1.22.1) 49 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. (PHED 2021 / 1.26) 50 P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. (PHED 2021/1.23) 51 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge. (PHED 2021/1.25) 52 Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 (PHED2021/3.3.1) 53 100 KL capacity ( 3.3.1.3 ) 54 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. ( PHED2021/3.7 ) 55 100 mm (3.7.1) 56 150 mm (3.7.2) 57 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.(PHED 2021/5.5) 58 15.0 KW (20.0 HP)(5.5.7) 59 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 35.0 Sq.mm, 3.5 core ( PHED 2021/2.20.4 ) 60 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 3 core 10.0 Sq.mm (PHED 2020/2.19.3) 61 SITC STAR DELTA Starter type LT Panel of followingrating:all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Baklight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Netural Links , Sprial , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminum Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. (PHED 2021/ 7.2) 62 STAR DELTA STARTER15.0 KW (20.0 HP) :For 2 motors (1 W+ 1S) I/C- MCCB 100A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3)and O/G-MCCB 63A TPN 25 KA With T/M Based Over Current & Short Circuit Protection (2), Power Cont 32A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) (PHED 2021/ 7.2.4) 63 Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 100 mm dia (PHED 2021/3.6.4) 64 Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.( PHED/2021/8.1 ) 65 120cm. high fencing with angle ironposts50x50x6mm.placedat every 3 Mtr. apart 30cm. in ground embeddedincementconcrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with three horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staple including earth work in excavation etc. complete. ( PWD Alwar 2019 / B_9.31 ) 66 Providingandfixingcowcatcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with primingcoatofredoxide(asper design). ( PWD Alwar 2019 / B_9.9 ) 67 Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints.( PHED 2021/8.30 ) 68 Brick work with F.P.S bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in: cement morter 1:4(1 cement :4 coarse sand) ( PWD Alwar 2019 / B_5.2.1 ) 69 E/W in excavationby mechanical means (hydraulic excavator/manual means over area (exceeding 30 cm in depth,1.5 mtr in width as well as 10 sqm on plan including disposal of excavated earth lead up to 1.5 mtr. Disposed earth earth to be leveled and neatly dressed all kind of soil ( PWD2019/B1/1.6 ) 70 Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm Dia ( PWD2019/S4/4.24.1 ) 71 Supply & fixing Pre cast RCC ring at mouth of recharge shaft of M20 mix with 40 mm thickness 900mm dia ( PWD2019/S4/4.25.1 ) 72 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. ( PWD2019/B-4 /4.9 ) 73 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.hot rolled deformed bar (IS:1139) ( PWD2019/B-4 /4.13.2 ) 74 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix ( PWD2019/B-4 /4.1 ) 75 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). ( PWD2019/S4/3.1.2 ) 76 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids 77 Size 9 to 12 mm ( PWD2019/S4/4.28.1 ) 78 Size 3 to 5 mm( PWD2019/S4/4.28.2 ) 79 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids.( PWD2019/S4/4.29 )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
38.
Drinking Water Supply and Sanitation #9107161 Technical Bid
tender for Work of construction of Sources, rising main pipelines,CWR, OHSR,Pump house internal village distribution pipeline and FHTC including one year Defect Liability period of Village Kalyanpura-Khera kalyanpur under Sub division Kathumar under JJM in the jurisdiction of PHED Division Kathumar (Alwar) Sl. No. Item Description 1 Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. 2 Nominal bore 200 mm dia. 3 Add 15% extra on above itemfor drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. 4 Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work will include lowering of housingand strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed afterobtaining sand free water. 5 Nominal bore 200 mm dia. 6 Add 15% extra on above itemfor drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr . 7 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 8 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 9 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 10 200 mm dia 11 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 12 200 mm dia nominal bore of 5.4mm thickness 13 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 14 11 KW (15 HP) & head above 120 mtr. 15 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 16 3 core 4.0 Sq.mm 17 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 18 16.0 Sq.mm, 4 core 19 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 20 50 mm dia 21 Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casing pipe for submersible cable external work 40 mm dia complete in all respect. 22 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 23 Manually Operated CI Sluice valve of Class PN-1.0 24 80 mm HW 25 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 26 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 27 Above 10 HP and up to 15 HP 28 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 29 Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. 30 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 31 M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size). 32 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 33 80 mm dia. nominal bore 34 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 35 HDPE PE-80PN-10 36 110 mm dia 37 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 38 HDPE PE-80PN-10 39 140 mm dia 40 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 41 Manually Operated CI Sluice valve of Class PN-1.0 42 80 mm HW 43 125 mm HW 44 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 45 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. 46 300 mm Dia 8 mm thick casing pipe. 47 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 48 HDPE PE-80PN-6 49 75 mm dia 50 90 mm dia 51 110 mm dia 52 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 53 HDPE PE-80PN-6 54 125mm dia 55 140 mm dia 56 160 mm dia 57 180 mm dia 58 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 59 Manually Operated CI Sluice valve of Class PN-1.0 60 80 mm HW 61 100 mm HW 62 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 63 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 64 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 65 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 66 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 67 RCC Valve chamber (2 No.) 68 Earth work In excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth. 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50m and all lift upto 1.5m, disposed earth to be levelled and neatly dressed. All type of Soil 69 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. 1:4:8 ( 1 cement : 4 coares sand : 8 graded stone aggregate 40mm nominal size) 70 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). 71 Plaster on new surface on walls in cementsandmortar1:4including rackingofjointsetc.complete fine finish : (20 mm thick) 72 Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointingwith cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects : 73 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coares sand : 4 graded stone aggregate 20mm nominal size) 74 S&F RCC Manholes covers with frame of approved make (Light duty) Size 600x600mm Double seal 75 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. 76 MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) 77 Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - 78 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. 79 h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 80 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 81 50 KL capacity 82 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 83 150 mm 84 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. 85 d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j)Providing and fixing water level indicator(float type).k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. 86 l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 87 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 18 M 88 200KL capacity 89 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 90 100 mm 91 200 mm 92 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 93 Manually Operated CI Sluice valve of Class PN-1.0 94 100 mm HW 95 200 mm HW 96 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 97 BFM 100 mm 98 BFM 200 mm 99 Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. 100 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 101 5.5 KW (7.5 HP) 102 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.35.0 Sq.mm, 3.5 core 103 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 104 3 core 10.0 Sq.mm 105 SITC STAR DELTA Starter type LT Panel of followingrating:all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Baklight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Netural Links , Sprial , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminum Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. 106 STAR DELTA STARTER 7.5 KW (10.0 HP)- : For 2 motors(1 W+ 1S) I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) andO/G-MCB 32A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2) 107 Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.100 mm dia 108 Recharge structure 109 E/W in excavationby mechanical means (hydraulic excavator/manual means over area (exceeding 30 cm in depth,1.5 mtr in width as well as 10 sqm on plan including disposal of excavated earth lead up to 1.5 mtr. Disposed earth earth to be leveled and neatly dressed all kind of soil 110 Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm Dia 111 Supply & fixing Pre cast RCC ring at mouth of recharge shaft of M20 mix with 40 mm thickness 900mm dia 112 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 113 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.hot rolled deformed bar (IS:1139) 114 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 115 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 116 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids 117 Size 9 to 12 mm 118 Size 3 to 5 mm 119 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 120 120cm. high fencing with angle ironposts50x50x6mm.placedat every 3 Mtr. apart 30cm. in ground embeddedincementconcrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with three horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed 121 with G.I. staple including earth work in excavation etc. complete. 122 Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. 123 Providing and laying in position cementconcreteincludingcuring, compaction etc. complete in specifiedgradeexcludingthecost ofcenteringandshuttering-All work up to plinth level. M15 grade Nominal Mix 1:2:4(1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size). 124 Brick work with F.P.S bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in: cement morter 1:4(1 cement :4 coarse sand) 125 Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. 126 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 127 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 128 P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. 129 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge..
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
39.
Drinking Water Supply and Sanitation #9107153 Technical Bid
tender for Work of construction of Sources, rising main pipelines,CWR, OHSR,Pump house internal village distribution pipeline and FHTC including one year Defect Liability period of Village Titpuri under Sub division Kathumar under JJM in the jurisdiction of PHED Division kathumar (Alwar) Sl. No. Item Description 1 Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strataunconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and its packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & its primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. 2 Nominal bore 200 mm dia. 3 Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. 4 Nominal bore 200 mm dia. 5 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 6 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 7 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 8 200 mm dia 9 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 10 200 mm dia nominal bore of 5.4mm thickness 11 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 12 9.3 KW (12.5 HP) & head above 120 mtr. 13 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 14 3 core 6.0 Sq.mm 15 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 16 16.0 Sq.mm, 4 core 17 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 18 50 mm dia 19 Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casing pipe for submersible cable external work 40 mm dia complete in all respect. 20 Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes 21 80 mm dia 22 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 23 Manually Operated CI Sluice valve of Class PN-1.0 24 80 mm HW 25 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 26 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 27 80 mm dia 28 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 29 Above 10 HP and up to 15 HP 30 Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 31 Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge. 32 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 33 M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size). 34 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 35 80 mm dia. nominal bore 36 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 37 HDPE PE-80PN-10 38 90 mm dia 39 110 mm dia 40 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 41 HDPE PE-80PN-10 42 125 mm dia 43 140 mm dia 44 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 45 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 46 Removing& Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technical specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) 47 60 mm thick. 48 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 49 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 50 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 51 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification. 52 300 mm Dia 8 mm thick casing pipe. 53 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 54 HDPE PE-80PN-6 55 75 mm dia 56 90 mm dia 57 110 mm dia 58 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 59 HDPE PE-80PN-6 60 125mm dia 61 140 mm dia 62 160 mm dia 63 180 mm dia 64 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 65 200 mm 66 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 67 Manually Operated CI Sluice valve of Class PN-1.0 68 80 mm HW 69 100 mm HW 70 150 mm HW 71 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 72 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 73 Removing& Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technical specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) 74 60 mm thick. 75 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 76 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 77 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 78 RCC Valve chamber (4 No.) 79 Earth work In excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth. 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50m and all lift upto 1.5m, disposed earth to be levelled and neatly dressed. All type of Soil 80 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. 1:4:8 ( 1 cement : 4 coares sand : 8 graded stone aggregate 40mm nominal size) 81 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). 82 Plaster on new surface on walls in cementsandmortar1:4including rackingofjointsetc.complete fine finish : (20 mm thick) 83 Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointingwith cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects : 84 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coares sand : 4 graded stone aggregate 20mm nominal size) 85 S&F RCC Manholes covers with frame of approved make (Light duty) Size 600x600mm Double seal 86 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. 87 MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) 88 Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: - 89 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. 90 h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 91 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 92 75 KL capacity 93 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 94 100 mm 95 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 96 Manually Operated CI Sluice valve of Class PN-1.0 97 100 mm HW 98 150 mm HW 99 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. 100 d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j)Providing and fixing water level indicator(float type).k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. 101 l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 102 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 20 M 103 300KL capacity 104 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 105 100 mm 106 150 mm 107 200 mm 108 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 109 Manually Operated CI Sluice valve of Class PN-1.0 110 100 mm HW 111 150 mm HW 112 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 113 BFM 100 mm 114 BFM 150 mm 115 BFM 200 mm 116 Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. 117 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 118 11 KW (15 HP) 119 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.35.0 Sq.mm, 3.5 core 120 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 121 3 core 10.0 Sq.mm 122 SITC STAR DELTA Starter type LT Panel of followingrating:all switchgears are of PHED approved makes, CRCA sheet of Panel enclosure is of TATA/ Essar 1.6mm/ 2.0mm thick duly Electrostatic Powder Coated with angle frame including other ancillaries ( Insulators, Acrylic Sheet , Baklight Sheet, Hardware, Wire, Name Plates, Lugs, Pvc Channel , Mcb Chanel , Lock, Hing , Bidding , Connectors, Netural Links , Sprial , Saddle & Packing Material ) etc. and 100A/ 125A ,TPN, Aluminum Bus Bar with Colour coated heat shrinkage sleeves complete as per Technical Specifications and as per direction of Engineer-In-Charge. 123 STAR DELTA STARTER 11.0 KW (15.0 HP)- :For 2 motors (1 W+ 1S) I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G-MCB 40A ,TP, 10 KA, C Curve (2), Power Cont 25A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (9-13A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) 124 Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.100 mm dia 125 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. 126 MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) 127 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 128 Manually Operated CI Sluice valve of Class PN-1.0 129 100 mm HW 130 150 mm HW 131 Recharge structure 132 E/W in excavationby mechanical means (hydraulic excavator/manual means over area (exceeding 30 cm in depth,1.5 mtr in width as well as 10 sqm on plan including disposal of excavated earth lead up to 1.5 mtr. Disposed earth earth to be leveled and neatly dressed all kind of soil 133 Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm Dia 134 Supply & fixing Pre cast RCC ring at mouth of recharge shaft of M20 mix with 40 mm thickness 900mm dia 135 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 136 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.hot rolled deformed bar (IS:1139) 137 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 138 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 139 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids 140 Size 9 to 12 mm 141 Size 3 to 5 mm 142 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 143 120cm. high fencing with angle ironposts50x50x6mm.placedat every 3 Mtr. apart 30cm. in ground embeddedincementconcrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with three horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed 144 with G.I. staple including earth work in excavation etc. complete. 145 Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. 146 Providing and laying in position cementconcreteincludingcuring, compaction etc. complete in specifiedgradeexcludingthecost ofcenteringandshuttering-All work up to plinth level. M15 grade Nominal Mix 1:2:4(1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size). 147 Brick work with F.P.S bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in: cement morter 1:4(1 cement :4 coarse sand) 148 Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. 149 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 150 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 151 P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. 152 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge..
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
40.
Drinking Water Supply and Sanitation #9107147 Technical Bid
Tender For Work Of Construction Of Sources, Rising Main Pipelines,Cwr, Ohsr,Pump House, Internal Village Distribution Pipeline And Fhtc Including One Year Dlp Of Village Khohra Under Sub Division Laxmangarh Under Jjm In The Jurisdiction Of Phed Divi Kathumar - Work of construction of Sources, rising main pipelines, RCC Reservoir, internal village distribution pipeline and FHTC including one year Defect Liability period at Villages KHOHRA in Sub division LAXMANGARH under JJM in the jurisdiction of PHED Division Kathumar Alwar Sl. No. Item Description 1 TUBEWELL WORK 2 Construction of tube well from ground level and up to 100 mtr depth and above to accommodate housing assembly pipe in all type of unconsolidated formation such as pebbles, boulders, collapsible formation etc. by Odex drilling method as per IS: IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work will include lowering of housingand strainer pipe assembly and casing shoe including cost of casing shoe, but excluding cost of the casing pipe. The work would be completed afterobtaining sand free water. Nominal bore 200 mm dia. 3 Nominal bore 200mm dia 4 Add 15% extra on above item (Item No 2.6.1 to 2.6.3) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr . 5 Construction of tube well after completion of drilling by rotary /percussion method & upto 100 mtr. depthin all type of rocks by DTH systemas per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The workshall be deemed completed only after obtaining sand free water. The bore well should have a throughout nominal size bore beyond casing pipe. 6 (a) Up to 100 Mtr. 7 Add 15% extra on above item (Item No 2.3.1 to 2.3.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. 8 Add 30% extra on above item(Item No 2.3.1 to 2.3.2) for drilling depth beyond 200 mtr and from ground level, rate shall be applicable for only extra depth beyond 200 mtr . 9 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 10 Labourcharges for making slots on blank pipes made of ERW MS black pipe ISI marked of following size, the slotting should be as per IS: 8110-1985. (a) 200 MM dia nominal bore of 5.4 mm thickness 11 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.(a) 200 MM Dia 12 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 13 9.3KW (12.5 HP) & head above 120 mtr. 14 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. (a) 3 core 4.00 Sq. MM 15 3 core 6.00 Sq. MM 16 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect.(a) 50 MM Dia 17 Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casing pipe for submersible cable external work 40 mm dia complete in all respect. 18 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.(a) 4 core 16.00 Sq. MM 19 Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes. 80 mm Dia 20 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually operated CI sluice valve of class PN-1.0 (80mm HW) 21 Plate Earthing as per IS: 3043 with G.I Earth plate of size 600mm X 600mm X 6.00mm by embodying 3 to 4mtr. below the ground level with 20mm Dia G.I B class watering pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel and C.C finished chamber covered with hinged type with locking arrangement C.I Cover, C.I frame of SIze 300mm X 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 22 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.50mm dia 23 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply.(a) above 10 HP and Up to 15 HP 24 Providing &fixing of pump safety cage as per specification as directed by Engineer. 25 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 26 Providing and fixing G.I. pipes complete with G.I.fittings including trenching and refilling etc. External work : 80 mm dia. nominal bore 27 PIPELINE WORK 28 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 29 all kind of soil 30 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 31 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 32 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 33 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 34 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 35 (HDPE PE-80 PN-6) 36 75mm 37 90mm 38 110mm 39 (HDPE PE-80 PN-10) 40 110mm 41 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. 42 (HDPE PE-80 PN-6) 43 140mm 44 (HDPE PE-80 PN-10) 45 140mm 46 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 47 Manually Operated CI Sluice valve of Class PN-1.0 48 80 mm HW 49 100 mm HW 50 150 mm HW 51 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendeduptodate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 52 100MM 53 150MM 54 Removing& Re-fixing of Precast concrete interlocking blocks by manual, stacking of serviciable & non serviceable material separately. disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlockingblock and cost of required new precast concrete interlocking block against damaged, including alllead and lift as per Technical specifications.(Interlocking blockmanufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm) 55 60MM THICK 56 Construction of RCC valve chamber for different type of valves including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall & cover slab all 125mm thick with C.I. surface box with hinged cover 100x100x75mm (deep), including cost of steelreinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. 57 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve 58 90cm x 90cm x 100cm (depth) for 200/250/300 mm dia valve 59 FHTC WORK 60 Providing Household Tap Connectionas per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PVC/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including MS/PVC saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valveand specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding),including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. 61 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 62 P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. 63 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 64 CWR PUMPING MACHINARY 65 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 66 20HP 67 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.25.0 Sq.mm, 3.5 core 68 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventor, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form.The size of CC plateform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for440 Volt AC Supply. 69 5 to 10 HP 70 Providing and fixing double flanged ISI markedGI pipes medium duty (class B ) Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736 with GI fittings excluding valves as vertical pipes for RCC Reservoirs including specials required such as bend, tee etc. providing and fixing with MS clamps clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 80 mm dia 71 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy(Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410 ,Hinge Maleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.of approved make (IS: 5312 amended upto date) of following Class and dia complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.80mm dia 72 RESERVOIR WORKS 73 Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 74 Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 75 100 KL capacity 76 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). 77 k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 78 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-IV & STAGING 18 M 79 150KL Capacity 80 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 81 100 MM Dia 82 150 MM Dia 83 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 84 BFM 150MM 85 PUMP HOUSE AND BOUNDRY WALL 86 Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. 87 Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC,600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. 88 Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. 89 RECHARGE STRUCTURE 90 E/W in excavationby mechanical means (hydraulic excavator/manual means over area (exceeding 30 cm in depth,1.5 mtr in width as well as 10 sqm on plan including disposal of excavated earth lead up to 1.5 mtr. Disposed earth earth to be leveled and neatly dressed all kind of soil 91 Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm Dia 92 Supply & fixing Pre cast RCC ring at mouth of recharge shaft of M20 mix with 40 mm thickness 900mm dia 93 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 94 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.hot rolled deformed bar (IS:1139) 95 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 96 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M15 grade Nominal Mix 1: 2: 4(1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 97 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids 98 Size 9 to 12 mm 99 Size 3 to 5 mm 100 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
41.
Drinking Water Supply and Sanitation #9100901 Technical Bid
Tender For Rural Water Supply Scheme For Village Amjara, Panchayat Amjara Of Block-Dungarpur Dist Dungarpur Through Fhtc Under Jal Jeevan Mission., 1 Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382- 1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge.excluding earth work)Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately 2 80 mm dia 3 100 mm dia 4 150 mm dia 5 200 mm dia 6 250 mm dia 7 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-9 gradeS&Spipesas per IS:8329-2000 (amendeduptodate),with internalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 8 100 mm dia 9 150 mm dia 10 200 mm dia 11 250 mm dia 12 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work).Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in Meter measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.HDPE PE-100 PN-6 (Dia in mm) 13 75 mm dia 14 90 mm dia 15 110 mm dia 16 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work).Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in Meter measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M.HDPE PE100 PN-6 (Dia in mm) 17 125 mm dia 18 140 mm dia 19 160 mm dia 20 180 mm dia 21 200 mm dia 22 225 mm dia 23 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safetyprovisions etc. 24 In all types of Soils 25 upto 1.5 m 26 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable materials for measurements and disposal of unserviceable materials as directed within a lead of 50 Mtr. including required all safety provisions etc.: 27 In Soft Rock 28 upto 1.5 m 29 In Hard Rock (Blasting Required) 30 upto 1.5 m 31 In Hard Rock (Blasting Prohibited) 32 upto 1.5 m 33 Dismantling of flexible pavement for pipe line line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters.Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. 34 Bituminous courses 35 Granular courses 36 Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasksas per technical specification and scope of work. 37 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification andscope of work. 38 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 39 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confiMetering to BS- EN1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confiMetering to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 40 80 mm dia 41 100 mm dia 42 125 mm dia 43 150 mm dia 44 200 mm dia 45 250 mm dia 46 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizes includingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 47 80 mm dia 48 100 mm dia 49 125 mm dia 50 150 mm dia 51 200 mm dia 52 250 mm dia 53 Providing, Supplying and fixing of D/F DI Pressure Reducing Valve in pipe line including jointing etc. complete as per standard/ technical specification and direction of Engineer-in-Charge. 54 100mm diameter 55 Construction of Sluice Valve Chamber in required size and shape as per drawing including required excavationof earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in chargematerial within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it withcovering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge 56 60cm x 60cm x 75cm (depth) for 80/100/125/150 mm dia valve 57 1200cm x 1200cm x 1300cm (depth) for 80/100/125/150 mm dia valve 58 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedupto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water,Valves including all mateial, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 59 Class PN 1.6 60 50 mm 61 80 mm 62 Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as per detailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. and suitable provision shall be included in tender document. 63 Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr.Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty.All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. and suitable provision shall be included in tender document. 64 Work includes designing of solar panel area and structure, showing arrangement of panel on rectangular OHSR with flat roof/ MS fabricated structure with polyethylene tank 65 120cm. high fencing with angle iron posts 50x50x6mm. placed at every 3 Mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner & every tenth posts to be strutted with 50x50x6mm angle iron provided with three horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staple including earth work in excavation etc. complete. 66 In flates, tees, angles & Channals 67 Providing and fixing 1.2 metres high GI barbed wire fencing with 1.8 m angle iron posts 40 mm x 40 mm x 6 mm placed every 3 metres center to center founded in M15 grade cement concrete, 0.6 metre below ground level, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with 9 horizontal lines and 2 diagonals interwovenwith horizontal wires, fixed with GI staples, turn buckles etc complete as per clause 807 of MoRTH specification & type A as per IS : 278-1978 size designation 5 (line wire 2.24, point wire 2.00mm mass 97-106 g/m) includiing all material, labour. 68 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 69 Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and2 pole motor operating at syncronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 70 2.2 KW 71 3.7 KW 72 5.5 KW 73 7.5 KW 74 9.3 KW 75 11.0 KW 76 15.0 KW 77 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer,phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level.The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 78 Up to 5.00 HP 79 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gaugeM.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 80 Above5 HPand upto 10 HP 81 Above 10 HP and up to 15 HP 82 Above 15 HP and up to 20 HP 83 Above 20 HP and up to 30 HP 84 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including makingconnection etc. 85 3 core 4.0 Sq.mm 86 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. asrequired of size. 87 10.0 Sq. mm 4 core 88 Providing & Lowering in tube well ISI marked GI Pipe “B class as per IS:1239 or amendedup to date threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete inall respect. 89 32 mm dia 90 50 mm dia 91 65 mm dia 92 80 mm dia 93 Providing, lowering, aligning, fixing in position in pipe line, CIdouble flangedDual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications:Body & Cover of Grey cast iron ofIS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality) ,Body seat of SS ,Face to face dimensions as per API: 594 ,Flanges Drilled as per IS:1538.Epoxy (Non-Toxic & suitable for drinking water) applied on body & coverinside and outside .Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,SpringSS AISI 316/304 , Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling jointsand earth work.as per API: 594 and flanges as per ISS of approved makeof following Class and dia complete including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 94 Class PN 1.0 95 100 mm dia 96 Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valave of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalentgrade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF- 8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside.Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 304/410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel) ,Insersion rubber of black EPDM 6mm thick .Suitable support structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.6 97 80 mm dia 98 100 mm dia 99 125 mm dia 100 150 mm dia 101 200 mm dia 102 250 mm dia 103 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 104 80 mm dia 105 100 mm dia 106 125 mm dia 107 150 mm dia 108 200 mm dia 109 Providing , lowringlaying , aligninng, fixing in position at all level/ depthC.I. class-B specials as per IS:1538, amended up to date in trench complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical specification and as per direction of Engineer( Note:- E/W to be measured and paid seperately) plain ended CI specials including tail pice, spigot end and socket end. 110 Upto 300mm 111 GSM Modem for SMS Facility- 24 V DC operated for bulk flow meter to transmit reading offlow meter to LCC/MCC Centre 112 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holdingthe riser pipe assembly of submersible pump set. 113 Construction and commissioning of RCC INTZE type Over Head Service Reservoir offollowing capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - 114 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M- 15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container.i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). 115 k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 116 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II20 M Staging 117 100 KL, staging Height 20 m 118 150 KL, staging Height 20 m 119 200 KL, staging Height 20 m 120 100 KL, staging Height 20 m 121 300 KL, staging Height 20 m 122 400 KL, staging Height 20 m 123 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II18 M Staging 124 100 KL, staging Height 18 m 125 150 KL, staging Height 18 m 126 200 KL, staging Height 18 m 127 250 KL, staging Height 18 m 128 300 KL, staging Height 18 m 129 400 KL, staging Height 18 m 130 Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: - 131 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M- 15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall.e) Successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container.i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab. 132 j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mmp) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 133 Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M 134 50 KL, staging Height 15 m 135 75 KL, staging Height 15 m 136 Providing Household Tap Connectionas per technical specification and approveddrawing asperrelevantIScode(amendeduptodate)from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanicalIntegrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceedingtheflowof7LPMat2barandacompressionelbow, mouldedinsingle piece(Completejob)includingdiggingoutsuitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming/compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specificationfor potablewaterincludingGMFull-wayValve(IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE 80PN16asperISO4427/20mmnominal diaPPR-C(Three layered) pipe PN16 SDR7.4 (IS:15801:2008)(ISI mark)and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premisesforfixinga tap/ meterbox (excluding),including accessories withflushing,cleaning, disinfectingandtestingofpipelinecomplete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note:Roadcutandrestorationisnotpartofthis itemandpaid separately. 137 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 138 Providing and fixing ISI mark (IS 9763: 2000 or amended upto date) PTMT bib cock 15 moinal bore minimum weight 92 gms and length 100 mm as per technical specification,approved make and direction of Engineer in charge. 139 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 140 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 141 M20 grade Nominal Mix 142 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 143 Earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 Mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil asdirected with in lead of 50 mtr. All kinds of soil. 144 Providing and laying in position cement concrete including curing compaction etc . Complete in specified grade excluding the cost of centering and shuttering. All workto plinth level usingcrusher broken aggregate 145 M10 grade Nominal Mix ( with graded stone aggregate 20mm nominal size) 146 M15 grade Nominal Mix ( with graded stone aggregate 20mm nominal size) 147 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases ofcolumns etc. 148 P & F on wall face A.C. pipes (IS : 1626 part-I mark) of approved make with wooden plugs and M.S. clamps, jointing with spun yarn soaked in bitumen and C.M. 1:2 complete includingmaking good the wall.: 100mm dia. 149 Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 150 100 mm dia 151 150 mm dia 152 200 mm dia 153 250 mm dia 154 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-incharge.MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) 155 Earth work in excavation over areas (exceeding 30cm depth, 1.5 mtr in width and 10 SQM in plan)for construction of open well, lift up to 1.5 Mtr. including taking out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 meter. All kinds of soil. 156 From0 m to 1.5 m BGL 157 Ordinary rock 158 From1.5 m to 6 m BGL 159 Hard rock (requiring blasting) usefulmaterial 30 % 160 From6 m to 7 m BGL 161 From7 m to 20 m BGL 162 Add extra over item No 1 for every additional; lift of 1.5 m or part thereof. 163 All Kind Of soil 164 In Ordinary Rock 165 In hard rock 166 From4.5 m to 6.0 m BGL 167 From6.0 m to 7.5 m BGL 168 From7.5 m to 9.0 m BGL 169 From9.0 m to 10.50 m BGL 170 From10.50 m to 12.0 m BGL 171 From12.0 m to 13.50 m BGL 172 From13.50 m to 15.0 m BGL 173 From15.0 m to 16.50 m BGL 174 From16.50 m to 18.0 m BGL 175 From18.0 m to 20 m BGL 176 Add 20% extra over item No. 2.39 for excavation in saturated soil where pumping or baling out of water is required, including shoring strutting where required and dewatering.(Respective applicable rates)From6 m to 18 m BGL 177 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for :Walls (any thickness) including attached pilasters,buttressesplinthandstring course.Add extra for shuttering in circular work in plan up to dia 10m over item Nos. 4.7.1 to4.7.2 178 Addextra for shuttering in circular work in plan upto dia 10m on item no. 4.7.1 179 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floorthree level. 180 Thermo-mechanically Treated bars (Conforming of relevent IS code) 181 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost ofcentering, shuttering and reinforcement. 182 Walls (any thickness) including attached pilasters buttresses, plinth and string courses filletscolumns pillars pears abutments posts struts etc. 183 M20 Grade nominal mix (with graded stone aggregate 20mm nominal size) 184 Structural steel work in single section fixed with connecting plate includingcutting hoistingfixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr. height 185 Filling available excavated earth (excluding rock) in trenches plint side of foundation etc. in layers not extending 20cm in depth, consolidating each deposited layer by ramming &watering including lead upto 50m. 186 Labour charges for horizontal boring 100 mm dia in open well in rocky stratawith all types of rock cutting & drilling tools etc. including all T&P required for job including dewateringarrangement. 187 Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification.300 mm Dia 8 mm thick casing pipe with protective coating. 188 AIR PILLAR 189 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 190 upto 1.5 mtrs 191 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 192 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement.M20 grade Nominal Mix / Design MixProviding M-25 grade concrete by using min 410 kg of cement per cum instead ofM-20 grade design mix. 193 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required) excluding the cost of centering, shuttering and reinforcement for Walls (any hickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 194 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases ofcolumns etc. 195 Footing PCC 196 Base Slab 197 Pillar below GL 198 Total 199 Columns, pillars, posts and struts etc. (Pillar above GL) 200 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) 201 River/Canal Crossing Estimate 202 Earth work in excavation over areas (exceeding 30cm in depth, 1.5 Mtr. in width as well as 10 Sqm on plan) including disposal of excavated earth lead up to 50m and with all liftdisposed earth to be levelled and neatly dressed: 203 Pumping out water caused by springs, tidal or river seepage, broken water mains or drainsand the like with pumping set of following H.P. including P.O.L./Power consumption etc. complete. 204 5 - 9 HP 205 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 206 M10 grade Nominal Mix (with graded stone aggregate 20mm nominal size). 207 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost ofcentering, shuttering and reinforcement. M25 208 Footing 209 Column upto GL 210 Column above GL 211 Subtotal 212 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 213 Centering and Shuttering with plywood or steel sheets including strutting, propping bracingboth ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of columns etc. up to plinth level. 214 Footing 215 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with wooden members and removal of formwork for upto floor three level for : 216 Column 217 Columns, pillars, posts and struts etc. 218 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 219 Thermo-mechanically Treated bars (Conforming of relevent IS code) 220 Provision for construction of switch room of size (4m x 3 m) 221 Earth work in excavation over areas (exceeding 30 Cm. In depth, 1.5 Mtr. In width as well as 222 Random Rubble stone masonry for foundation and plinth in cement sand mortar above 30cm thick wall in 223 In cement mortar 1:6 (1 cement : 6 coarse sand) 224 Honey comb brick work 23 cm thick with bricks of class designation 75 up to third storey in : 225 Cement mortar 1:4 (1 cement : 4 coarse sand) 226 Deduction of Door 227 Deduction of Window 228 Plaster on new surface on wall in cement sand mortar 1:4 including raking of joints etc.complete fine finish : (12mm thick) 229 1:4 (1 cement :4 fine/ coarse sand) 230 Deduction of Door 231 Deduction of Window 232 Cement concrtete grade 1:2:4 (1 Cement: 2 Coarse sand : 4 graded stone aggregate ) 233 75mm thick with 20mm thick nominal size aggregate 234 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishingand reinforcement: 235 M20 grade Design mix (with weight batching plant only) 236 Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strapbeams, bases of columns , etc. up to plinth level. 237 Wall (any thickness) including attached pilasters, buttresses, plinth and string course 238 Suspended floors, roofs, landings, balconies and access platform. 239 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing inposition and binding all complete 240 Thermo-Mechanically Treated bars 241 Providing & fixing door, window, chowkhats and other frames, including antitermite treatment,M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Sheesham wood Grade-1 242 P & F IP-65 protected street light luminaire on existing bracket suitable for HPSV/ MH LAMP, made from powder coated single piece pressure die cast aluminium housing, electrochemically brightened and anodized POT optics aluminium reflector, heat resistant and toughened glass cover and accessories like copper ballast, electronic ignitor, capacitor, holder prewired up to terminal block etc. as required including making connection testing etc.as required(without lamp) 243 Street Light Suitable for HPSV Lamps1 X 150 Watt 244 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked( IS:9537 P - II ) rigid steel conduit & its accessories, round tiles,18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board& false ceiling point,6 A switch, 3.0 mm thick ISI markedphenolic laminated sheet, pvc bushes, check nuts, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.Group-III 245 Short point (up to 3 mtr.) 246 Medium point (up to 6 mtr.) 247 Providing and fixing, flush door shutters non decorative type (hollow core construction) with internal frame of Ist grade wood having styles and top rails of 100 mm width & bottom and lock rails of 150 mm width with 3 Nos. cross battens of 50 mm thick width using 4 mm thick commercial ply on both faces of shutters & 6 mm thick beading of respective wood using with approved steel fitting as perAnnexure A :- 248 25 mm thick. 249 Sheesham wood grade – I 250 Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor1.1 kV grade (IS:694) and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) vergin material PVC conduit & its all accessories( J.B. , Bends etc.) , round tiles,18 SWGG.I. box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 - 1995), Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 251 Short point (up to 3 mtr.) 252 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 253 2 x 1.5 sq.mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
49.
Water Resources and Irrigation #8904085 Technical Bid
Manufacture And Supply , Installation , Testing And Commissioning Of Electrical And Mechanical Items In Babina Pump Canal On Turn Key Basis Distt . Jhansi.- 1 1 Supply, Installation , Testing And Commissioning Of External Clear Forced Water Lubricated Vertical Turbine Pump Set Of 35 Cusec Capacity, 35 Meter Head & Its Accessories. 4 Job 2 2 Supply, Installation , Testing And Commissioning Of Suitable 11 Kv H.T. Squirrel Cage Induction Motor With Accessories. 4 Job 3 3 Supply, Installation , Testing And Commissioning Of Suitable 11 Kv H.T Capacitor 4 Job 4 4 Supply, Installation , Testing And Commissioning Of Suitable 11 Kv H.T Panel 1 Set 5 5 Installation, Testing And Commissioning Of 700 Mm Butterfly Valve On Delivery Side Of Pump. ( Supply Will Be Givin By Deptt. ) 4 Nos. 6 6 Installation, Testing And Commissioning Of Non Return Valve ( Reflux Valve ) 700 Mm Dia. On Delivery Side. ( Supply Will Be Givin By Deptt. ) 4 Nos. 7 7 Supply, Installation / Laying , Testing And Commissioning Of 700 Mm Dia. Ms Pipe ( Connection Piece, Bends, Concentric / Eccentric Taper, Puddle Pipes, Ms Flange Drilled Etc. ) , Dismantling Joints, Air Release Valve Of 150 Mm, Insertion Sheets, Nut, Bolts Etc. Length Of Each Delivery Piping Shall Be Approximately 300 Meter. ( Excluding Cost Of M.S.Flanged Pipe 700 Mm Diameter.It Will Be Supplied By Department. ) 1200 Meter - Erection Of Flanged M.S.Pipe 700 Mm Ø, 8.0 Mm Thickness ( It Will Be Supplied By Department. ) 4 Nos.-Connection Piece With Seal 16 Nos. -M.S.Bend 700 Mmø Of Various Angles 4 Nos. - Dismantlling Joints 4 Nos. - Expander On Delivery Sides 600X700 Mmø 4 Nos. - Air Release Valve / Sluice Valve 150 Mmø 4 Nos. - Spring Loaded Pressure Release Valve 150 Mmø 4 Nos - Syphonic Bends Ls - Concentric / Eccentric Taper, Puddle, Pipes 1 Job 8 8 Supply, Installation , Testing And Commissioning Of All Control & Instrumentation- Pressure Gauge Of 150 Mm, Pressure Transmitter, Ultrasonic Level Transmitter, Ultrasonic Remote Flow Meter Of 700 Mm For Each Pumps, Rtd, Btd, Temperature Gauge, Vibration Sensor, Level Switch, Plc + Scada, Cc Tv Camera. Iot Device To Monitor Critical Parameters Of Pump On Cloud, Spares & Alarm Management Though Cloud. Data Shall Be Monitored On Pc / Laptop / Mobile. In All Four Pump Sets -04Nos. 1 Job 9 9 Fire Extinguishers Supply, Installation , Testing And Commissioning Of 04 Nos. Co2 Type, 9 Kg, 04 Nos. Of Co2 Type, 4.5 Kg And 04 Nos. And Of Fire Buckets 9 Litres Along With Stand Complete 1 Job 10 10 Supply, Installation , Testing And Commissioning Of Indoor And Outdoor Lighting System Includes As Follows- 10 Nos. - T.P. Switch 100 Amps 10 Nos - T.P. Switch 100 Amps 50 Nos. - 5 To 15 Amps 250 Volts Switch Fuse Units 50 No.S - 5 To 15 Amps 250 Volts Plugs 20 Nos. - H.P.M.V. Lamps 400 Watts With Mould Acryli Cover Complete 20 Nos - H.P.M.V. Lamps 125 Watts With Mould Acrylic Cover Complete 8 Nos. - Side Wall Fan 600 Mm Air Circulatro 8 Nos - Exhaut Fan Tube Axial Type Capacity 1200 M³ / Hr 1 Job - L.T. Distribution Panel 200 Amps Capacity 250.0M - Power Wiring And Earthing Of Above 1 Job 11 11 Supply, Installation , Testing And Commissioning Of L.T. Control And Relay Panel Capacity 400 Amps. 1 Job 12 12 Supply, Installation / Laying , Testing And Commissioning Of 3X150 Mm ² 11 Kv Grade Xlpe Al Armoured H.T. Cables Including Jointing Kits And Cable Trays From 33 / 11Kv Sub-Station To H.T. Switch Gear Panel In P / H Of Canal 700M-3X150 Mm²11 Kv Grade Xlpe Al Armoured H.T. Cable 150-3X95 Mm²11 Kv Grade Xlpe Al Armoured H.T. Cable 50 Nos.- Jointing Kits 600M-Cable Tray 300 Mm Or As Per Relevant Is Code 1 Job 13 13 Supply, Installation , Testing And Commissioning Of Dewatering Pump 15 H.P. 2 Nos. 14 14 Supply, Installation , Testing And Commissioning Of 11 Kv Electric Shock Resistance Rubber Mats, Minimum 25 Mm Thickness, Approx.150 M² Area 100 Meter 15 15 Supply, Installation / Laying , Testing And Commissioning Of Various Size L.T. Cables And Control Cables Including Jointing Kits And Cable Trays In P / H Of Canal 400 Meter 16 16 Earthing Of Pump House By Supply, Installation / Laying , Testing And Commissioning Of Various Size L.T. Cables , Erathing Equipments, Materials, Lightening Arrestors, With Air Signal Light Inside And Outside P / H Of Canal 1 Job 17 17 Supply, Installation, Testing And Commissioning Of High Mast Tower With Led Lights Octagonal 25 Meters Height . 2 Job 18 18 Supply, Installation, Testing And Commissioning Of Battery Bank System 110 V, 3000 Ah, Including Dc Charger , Trolly , Plate Farm Etc. Completes 1 Job 19 19 Supply, Installation, Testing And Commissioning Of Water Fiteration Plant Capacity 240Liters / Min. Including Civil Works. 1 Job 20 20 Supply, Installation, Testing And Commissioning Of 63 Kva Generator Set Confirming To Cpcb Regulations .Excluding Civil Works. 1 Job 21 21 Operation Of Canal And Maintenance Of All Electrical & Mechanical Equipments I.E, Pump Motor H.T. / L.T. Panels, Capacitors , Automation Systems Completes For 2 Years Including All Technical Skilled / Unskilled Staff Required . 1 Job
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
50.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
TenderDetail
Loading tenders