View Bid Results For General Purpose Relay Tenders

We found 294 Bid Results related to general purpose relay tenders. You can find Contractor details who won general purpose relay tenders along with contract details in Bid awards announcements section.

Filters
Stage
255
28
11
Tender Publishing Platform
167
127
State / UT
30
26
25
25
22
21
18
17
16
14
13
12
11
11
8
6
6
6
5
5
4
4
3
3
3
2
2
2
2
1
1
Contract Value
96
130
38
29
Publish Date
1
0
0
0
0
Sector
21
106
75
30
18
10
9
5
5
5
5
4
3
3
3
2
2
2
2
2
2
1
Ownership
7
164
90
26
9
3
1
1
Within keyword
Active filters:
Showing 1–6 of 294 tenders matching your filters
2.
Educational and Research Institute #11308093 Price Bid
Tender for Purchase Of Lab Equipments For Ece Dept , Purchase Of Lab Equipments For Ece Dept , Dc Voltmeter (Digital) (Item Code : C006) 1.Dcvoltmeteranalog - Moving Coil -(0-10)V, Class1.0(±1%Full- Scale)Accuracy - 5 Nos 2.Dcvoltmeteranalog- Movingcoil-(0-30)V, Class1.0(±1%Full-Scale)Accuracy - 4Nos , Dc Ammeter(Item Code : C007) Specifications: •1. Dcammeteranalog-Movingcoil- (0-30)Ma,. 5 Nos 2. Dcammeteranalog -Movingcoil -(0-1000)Μa, Class 1.0 (±1 % Full-Scale) Accuracy - 5 Nos , Decade Capacitance Box(Item Code : C0011) Specifications: • Range: 100 providing fixing To 100 Μf • Rotary Switch Selection With 6 Dials. • Maximum Voltage: 350 V. • Accuracy: ±1%. , Decade Inductance Box(Item Code : C0012 Specifications: • Range:10Μhto10h. Rotaryswitchselectionwith6dials. • Low-Lossinductors. • Accuracy:±1%. , 8051 Microcontroller Kit(Item Code : C0013) Specifications: •• Operating Voltage: +5 V Dc. • Flash Memory: 4 Kb (At89c51) / 8 Kb (At89s52). • Ram: 128 Bytes Internal Ram. • 16 × 2 Alphanumeric Lcd Display. • Push Buttons / Tactile Switches. • Dip Switches For Digital Input. • Inbuilt Adc Interface: Ldr, Potentiometer. • Inbuilt Dac Interface. • Inbuilt Stepper Motor Driver With Stepper Motor. • Inbuilt Dc Motor Driver With Dc Motor. • 1 × 4 Led Array, 1 × 4 Keypad, 1 × Relay. • 1 × Buzzer, 16 × 2 Lcd Display, 1 × Pwm Driver. • 1 × Hardware Interrupt Key, Inbuilt Rtc. • Inbuilt Eeprom And Uart Module. • 4 × 7-Segment Display. • Supports Both Assembly And C Language Programming. • Pc Interfaceable. , Embedded Trainer Kit (Using Lpc2148) (Item Code : C0014) Specifications: • Cpu - Lpc2148, Core - 16/32 Bit Arm7tdmi-S • Speed - Max 60 Mhz, Flash - 512Kb, Ram (On Chip) - 40Kb, 46 General Purpose I/Opins, Usb2.0 • One 10Bit A/D Converter With 14 Analog Inputs, One 10Bit D/A Converter, Six Pwm & Watchdog • Two Uarts (16C550), Two I2c (400Kb/S), Two Spi • Eight Bit Digital Output, Eight Bit Digital Input,16X2 Characters Lcd And 4X4 Matrixkeypad • One Potentiometer For Giving Analog Input, Relay & Buzzer Interface • I2c Devices: Rtc, Eeprom And Seven Segment Display, On Board Stepper Motordriver • Lm35 Temperature Sensor, One Rs 232 Lines Are Terminated At 9 Pin D Type Connector And Usb Interface • Board Has Inbuilt Power Supply And Mounted In Sturdy Cabinet Accessories • Usb Cable With Utility Software To Download Programs From Pc To Target Board • Power Cord, User Manual , Temperature Measurement Kit (Item Code : C0019) Specifications: • Sensors: Rtd (Pt-100), Thermocouple (Fe-K/J-Type), And/Or Thermistor (Ntc). • Display: 3½ Digit Led/Lcd Digital Display (Typically 200 Mv Fsd). • Temperature Source: Portable Water Kettle Or Heater Block. • Signal Conditioning: On-Board Circuitry For Amplification, Linearization, And Cold Junction Compensation. • Test Points: Multiple 2 Mm / 4 Mm Banana Sockets For Monitoring Input/Output Signals. • Power Supply: 230 V Ac, 50 Hz, Single-Phase. • Accessories: Glass Thermometer, 10 K Ntc Thermistor Probe, K-Type Thermocouple Probe, Patch Cords And User Manual. , Fpga Trainer Kit(Item Code : C0025) Specifications: • Must Use Industry-Standard Mid-Range Fpga Device • Usb-Jtag Programmable, Compatible With Vivado Ise (Webpack). • Power Supply: 5 V Dc Through Usb Or External Adapter. • On-Board Peripherals: Leds, Switches, Push Buttons, 7-Segment Display,Clock Source, Gpio / Pmod Expansion Ports, Uart, Vga / Hdmi, Usb Uart Bridge, Usb Cable. •User Manual.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
3.
Heavy Industries and Public Enterprises #11307960 Technical Bid
Tender for Inviting Rates For Spare Parts And Repairing/Servicing Of Laptop/Computer/Printer/Ups, Different Types Of Cable For Computer Hardware, Stationary Items, General Items, Printer Cartridge, Photocopy And Rented Vehicle & Coolers. , Head Name - Computer Hardware , Com&Lap - Antivirus 1 Years , Com&Lap - Antivirus 3 Years , Com&Lap - Bios Battery , Com&Lap - C - Port To Hdmi , Com&Lap - C - Port To Lan , Com&Lap - Cabinet - Atx , Com&Lap - Cordless Keyboard , Com&Lap - Cordless Mouse , Com&Lap - Cpu Cooling Fan , Com&Lap - Desktop Computer Ram Ddr21gb , Com&Lap - Desktop Computer Ram Ddr22gb , Com&Lap - Desktop Computer Ram Ddr24gb , Com&Lap - Desktop Computer Ram Ddr32gb , Com&Lap - Desktop Computer Ram Ddr34gb , Com&Lap - Desktop Computer Ram Ddr48gb , Com&Lap - Desktop Harddisk 128 Gb , Com&Lap - Desktop Harddisk 256 Gb , Com&Lap - Desktop Harddisk 512 Gb , Com&Lap - Desktop Harddisk 1Tb , Com&Lap - Desktop Mother Board Board 945 , Com&Lap - Desktop Mother Board I3 , Com&Lap - Desktop Mother Board I5 , Com&Lap - Desktop Mother Board I7 , Com&Lap - Desktop Processor C2d , Com&Lap - Desktop Processor Dual Core , Com&Lap - Desktop Processor I3 , Com&Lap - Desktop Processor I5 , Com&Lap - Desktop Processor I7 , Com&Lap - Dvd Writter For Desktop , Com&Lap - Formating Charges , Com&Lap - Keyboard - Pin , Com&Lap - Keyboard - Usb , Com&Lap - Lan Card (Usb To Lan) , Com&Lap - Laptop Battery , Com&Lap - Laptop Charger , Com&Lap - Laptop Dvd Writter , Com&Lap - Laptop Harddisk 128 Gb , Com&Lap - Laptop Harddisk 256 Gb , Com&Lap - Laptop Harddisk 512 Gb , Com&Lap - Laptop Harddisk 1Tb , Com&Lap - Laptop Keyboard , Com&Lap - Laptop Processor & Board , Com&Lap - Laptop Ram Ddr2 1 Gb , Com&Lap - Laptop Ram Ddr2 2 Gb , Com&Lap - Laptop Ram Ddr2 4 Gb , Com&Lap - Laptop Ram Ddr3 2 Gb , Com&Lap - Laptop Ram Ddr3 4 Gb , Com&Lap - Laptop Ram Ddr4 4 Gb , Com&Lap - Laptop Ram Ddr4 8 Gb , Com&Lap - Laptop Touchpad , Com&Lap - Mouse Pad , Com&Lap - Mouse- Pin , Com&Lap - Mouse - Usb , Com&Lap - Pce Lan Card , Com&Lap - Pendrive 32 Gb , Com&Lap - Pendrive 64 Gb C Type Usb3.0 Otg , Com&Lap - Pendrive 64 Gb , Com&Lap - Smps 450W , Com&Lap - Smps 650W , Com&Lap - Smps Slim 450W , Com&Lap - Ssd 256 Gb Laptop And Desktop , Com&Lap - Ssd 512 Gb Laptop And Desktop , Com&Lap - External Ssd 256 Gb For Laptop And Desktop , Com&Lap - External Ssd 512 Gb For Laptop And Desktop , Com&Lap - External Ssd 1 Tb For Laptop And Desktop , Com&Lap - External Ssd 2 Tb For Laptop And Desktop , Com&Lap - External Ssd 4 Tb For Laptop And Desktop , Com&Lap - Ssd Nvme 256 Gb Laptop And Desktop , Com&Lap - Ssd Nvme 512 Gb Laptop And Desktop , Com&Lap - Ssd Nvme 1 Tb Gb Laptop And Desktop , Com&Lap - Usb Extension 4 Port , Com&Lap - Crt Est , Com&Lap -Crt Memory Ic Chip , Com&Lap - Crt Picture Tube , Com&Lap -Crt Power Supply Unit , Com&Lap -Crt Repairing & Service Charge , Com&Lap - Tft Picture Gum , Com&Lap - Tft Power Supply Unit , Com&Lap -Tft Repairing & Service Charge , Com&Lap - Tft Screen , Com&Lap - Cat6 Cable , Com&Lap - Convertor Hdmi To Vga , Com&Lap - Convertor Vga To Hdmi , Com&Lap - Power Cable For Desktop , Com&Lap - Power Cable For Laptop , Com&Lap - Power Cable For Printer , Com&Lap - Data Cable For Printer , Com&Lap - Vga Cable For Desktop , Com&Lap - Hdmi Cable 1 Mtrs , Com&Lap - Hdmi Cable 3 Mtrs , Com&Lap - Hdmi Cable 5 Mtrs , Com&Lap - Hdmi Cable 10 Mtrs , Com&Lap - Hdmi Cable 15 Mtrs , Com&Lap - Hdmi Cable 30 Mtrs , Com&Lap - Wifi Usb Mini Adapter , Usb To Rj 45 Ethernet Lan Adopter , C Type To Rj 45 Ethernet Lan Adopter , Com&Lap - Ms Office Home & Student 2021 , Com&Lap - 19 Inch Monitor (Tft) , Com&Lap - 27 Inch Monitor (Led) , Entry Level Printer - Adf Pickup Pad , Entry Level Printer - Drum Unit , Entry Level Printer - Ccd Unit , Entry Level Printer - Cap Hinges , Entry Level Printer - Control Pannel , Entry Level Printer - Dc Controller , Entry Level Printer - Drum Blade , Entry Level Printer - Fuser Unit , Entry Level Printer - Fuserdrum Gear , Entry Level Printer - Gear Assembly Unit , Entry Level Printer - Hbps Card , Entry Level Printer - Heat Roller , Entry Level Printer - Logic Card , Entry Level Printer - Lsu Unit , Entry Level Printer - Megnet , Entry Level Printer - Motor , Entry Level Printer - Paper Tray , Entry Level Printer - Pick Pad , Entry Level Printer - Pressor Roller , Entry Level Printer - Repairing & Service Charhes , Entry Level Printer - Scanner Unit , Entry Level Printer - Sensor Unit , Entry Level Printer - Sepration Paid , Entry Level Printer - Smps , Entry Level Printer - Teflon , Entry Level Printer - Solenoid (Relay) , Mfd Printer - Adf Pickup Roller , Mfd Printer - Drum Unit , Mfd Printer - C.C.D Unit , Mfd Printer - Cap Hinges , Mfd Printer - Control Pannel , Mfd Printer - Dc Controller , Mfd Printer - Drum Blade , Mfd Printer - Fuser Unit , Mfd Printer - Fuserdrum Gear , Mfd Printer - Gear Assembly Unit , Mfd Printer - Hbps Card , Mfd Printer - Heat Roller , Mfd Printer - Logic Card , Mfd Printer - Lsu Unit , Mfd Printer - Megnet , Mfd Printer - Motor , Mfd Printer - Paper Tray , Mfd Printer - Pick Roller , Mfd Printer - Pressor Roller , Mfd Printer - Repairing & Service Charhes , Mfd Printer - Scanner Unit , Mfd Printer - Sensor Unit , Mfd Printer - Sepration Paid , Mfd Printer - Smps , Mfd Printer - Teflon , Mfd Printer - Solenoid (Relay) , Ups - Invertor Card , Ups - Battery Charger (Heating Bridge) , Ups - Mospet , Ups - Resistance , Ups - Main Power Transformer , Ups - Capicitor , Ups - Inductor , Ups - Diode , Ups - Ic555 , Ups - Ic808 , Ups - Invertor Switch , Ups - Repairing & Service Charges Per Ups 500Va /650Va/ 750Va / 800Va/1000 Va , Ups - Battery - 7 Ah, 12 Volts, Smf , Head Name - Stationery Items , Printing Paper A4 (75 Gsm) , File Cover (Card Board Office File Cover, Paper Size: Fullscape) , File Pad (Cardboard Office File Pads) , All Pin Stanless Steel , Whitener Correction Pen 4 Inch , Pencil Black 6 Inch , Stapler Pin No 10 1M , Stapler Pin No 24/6 1M , Stapler N10 , Size: 4 Inch , Stapler Hp 45, Size: 7 X 3 X 17.5 Centimeters , Stapler Heavy Duty ,Stapling Capacity: 210 Sheets , Stapler Pin 23/10-H , Note Sheet Paper A4 Size , U Shape Paper Pin/Gems Clip , Stamp Pad Blue For Stamping Purpose Size 110Mmx70mm , Stamp Pad Blue For Stamping Purpose Size9.5 Cm X 5 Cm , Envelope White Paper For Letter, Courier And Documents, 90 Gsm, Size - 9 X 4 Inches , Envelope Yellow Inside Laminated11x5 Inch , White Board Marker Pen , Highlighter Pen For Marks Highlight Text-Line , Notes Paper Flags Re-Stick (25Mm X 75Mm) - 4 Colours , Magnetic Pin Cushion 7X4(Hxl)Mm , Stock Book With Amount Column - Hard Bound - Register Size - 32 X 20 Cm (90 Pages - Pack Of 1) , Gum Bottle 300Ml , Gum Bottle 700Ml , File Tag Thread Green 20 X 18 X 1 Centimeters (100 No) , File Tag Thread For Paper Binding - 6 Inch, White (100 No) , Dak-Pad (F/S Or Legal Size: 14.5 X 10 Inch) , Invert/Dispatch Register Etc. (Dispatch - 72Gsm 275 Pages) , Single Line Long Register (100 Pages) , Register 6Qr 16X26 Cm 400 Pages , Register 4Qr 16X26 Cm 200 Pages , Register 8Qr , 80 Gsm , Rubber Eraser For Pencil (Pack Of 10) , Bill Register 65 Gsm Green Ledger Paper, - Dimensions: 19.5 X 32.5 Cm( 4 Qr) , Shorthand Copy 100 Pages , Poker(Tocha) Plastic Handle 8 Inch , Steel Scale 12 Inch , Plastic Scale 12 Inch , Gel Pen 0.55Mm 10Pen Box Pack , Motor Vehicle Log Book - Hard Bound - 20 X 16 Cm , Self Adhesive Transparent Tapes 2.5Inchx65meters , Cello Tape 1 Inch 65M (Transparent) , Self Adhesive Brown Cello Tape - 100 Meters In Length - 48Mm / 2 Width , Glass Paper Weight 51D X 40W X 51H Millimeters , White Correction Fluid 15Ml , Daily Attendance Register, 75 Pages , Desk Table Plastic 15 X 21 Inch Top With Foldable Transparent, Adjustable 7Mm Writing Desk Stand, Z-Type , Desktop Calculator 150 Steps Check And Correct With Tax & Gt Keys & On Display Indication Of Active Constant , Glue Stick 25Gm , Ball Pen 0.7 Mm , Plastic L Folder, Clear Transparent Size Legal, F/S, ( Set Of 10 Pcs ) , Multicolor Plastic Envelope File Folder 13 Inch X 11 Inch , Leather, Foam Convocation File Folder, A4 , Register 3Qr , Register 2Qr , Executive Diary (75 Gsm Dual Color), B5 Size, Dated Diary , Pen Stand Compartments Wooden With Visiting Card & Mobile Holder For Office Table (Min Size 175 Mm, 75 Mm, 100 Mm) , Contingent Register-200 Folio , Paper Cutter 9Mm , Metal Binder Clip Double Clip Size 51 Mm , Pencil Sharpener Steel Blade , Cash Book As Mptc 5, A3 Size, 100 Pages, Min 80 Gsm Paper , Single Line 5 Subject Spiral Notebook (14 X 21.6 Cm) 70 Gsm , Envelope Laminated Yellow Paper Legal Size | Poly Laminated Inside | 10 X 14 Inch , Envelope Laminated Yellow Paper A3 Size | Poly Laminated Inside | 10 X 14 Inch , A4 Size Envelop Laminated Yellow10 X 12 Inch , Letter Head 125 Gsm, White , Colour Flag 3 X 3 , Visiting Card , Cartridge Sheet (140Gsm) , Sketch Pen 12Shade Multi Colour , Jute Folder (A4 Size) , Leather Multipurpose File Folder (A4 Size) , Jute Office Bag ( 38L X 10W X 30H Cms ) , Bond Paper A4 (100 Gsm) , Colour Copy & Printing Paper A4 (100 Gsm) , Excellence White Printing Paper A4 (100 Gsm) , Paper Sheets A4 (140 Gsm) , Punching Machine 1 Hole, Punching Capacity : Minimum 60 Sheets , Punching Machine 2 Holes, Punching Capacity : Minimum 20 Sheets , Punching Machine 2 Holes, Punching Capacity : Minimum 60 Sheets , Poker (Tocha) Metal Handle 8 Inch , Scissors Steel 5 Inches , Scissors Steel 9 Inches , Head Name - General Items , Milk Powder For Tea 500 Gram Pack , Packaged Drinking Water 200 Ml , Packaged Drinking Water 500 Ml , Packaged Drinking Water 1 Ltr. , Green Tea - Detox/Desi Kahwa, 25 G (10 Bags X 2.5 G Each) , Honey Lemon Green Tea Bags, 35 G (25 Bags X 1.4 G Each) , Biscuit Butter/Cashew/ 50G Pack , Biscuit Tastier Sweet-Salty Crackers 75G Pack , Biscuits High Fibre 100G Pack , Sugar Cube, 500 G Pack , Sugar , Tea Premium With Long Leaves 500G , Coffee Pouch, 1Pcs Instant Coffee(60 X 1.67 G) , Samosha/Kachori , Khaman Dhokla 2 Pcs. , Chips 100 Gram , Mithai 500 Gram , Buttermilk (Matha/Chach) 250 Ml. , Namkeen 50 Gram , Lunch Or Dinner Thali ( Daal, Rice, Paneer Sabzi, Seasonal Veg, Curd Item, 5 Tawa Rotis, 1 Pcs. Sweet & Salad ) , Tea Cup Bone China White Color Gold Design 160 Ml , White Tea Cup Set Of 6, , Plate Bone Ash Free Quarter Plate 7.5(6 Pcs) , Serving Tray Platter Rectangular Plastic Tray 35L X 25W X 4H Centimeters , Electric Kettle 1.8L, Stainless Steel Inner Body - Auto Power Cut, Boil Dry Protection & Cool Touch Double Wall, Portable | 1500 Watts, Size- 24L X 20W X 28H Centimeters , Electric Kettle, Stainless Steel Quick Boil, 1 Ltr, 7.9L X 6.3W X 7.9H Centimeters , Transparent Water Glass Set Of 6 Pcs (300 Ml Each) Large Flame Proof Round Shape Glasses , Spoon Stainless Steel Set Length 16.6Cm (Medium, Set Of 12) , Tissue Paper 30X27 Cm (100 Sheets Per Pack) , Facial Tissue 2 Ply Soft Pack - 200 Pulls , Dishwash Bar, 125G , Air Freshener 48 G (Pack) , Room Freshener Spray (220 Ml) , Detergent Bar, 110 G , Mosquito Vaporiser Refill + Machine - 45Ml , Liquid Vaporiser Mosquito Repellent Refill 45 Ml , Tea Strainer Chai Chalni Stainless Steel , Thermos, Thermo Steel Vacuum Insulated 24 Hours Hot Or Cold Carafe, 1000 Ml , Handwash Refill - Skincare Hand Wash- 1500Ml Pack , Dishwash Liquid , 250 Ml Bottle , Men Raincoat Free Size , Umbrella- 54 Inch Heavy Duty , Pre Ink Stamp Small 1.2Cmx3.6Cm , Pre Ink Stamp Size 2.1Cmx5.7Cm , Cell Carbon Zinc Aa Battery - 10 Pieces , Cell Aaa Batteries - Pack Of 10 , Nameplate Fiber 6 X 12 , Double Side Name Plate , Name Plate Big Size 10 X 12 , Door Bell (Wireless) , Door Locks (Tala) , Plastic Open Dustbin, (8 L) , Plastic Pedal Dustbin , 10 L , 9 Watt Led , 12 Watt Led , Tube Light Led (15 Watt) , Electric Cable(3Colour) , Cooler Pad, Khus (4 Feet) , 3 Pintop (5A) , 3 Pintop(15A) , Gi Wire (1Kg) , Modular Socket (5Amp) , Socket Modular (5Amp) , Extension Board - 5 Power Sockets, 15 Amps 2Mtr , Extension Board - 5 Power Sockets, 15 Amps 3Mtr , Extension Board - 5 Power Sockets, 15 Amps 5Mtr , Wire 3 Cable Core , Office - Identity Card Pvc (Standard Size) With Card Holder & Strap , Round White Disposable Paper Plates Size : 6 Inches (Pack Of 50 Plates) , Disposable Wooden Spoons Length : 14 Cm. (Pack Of 100 Pcs.) , Head Name - Printer Cartridge (Original) , Toner Cartridge Canon 303 , Toner Cartridge H.P. 12A , Toner Cartridge H.P. 53A , Toner Cartridge H.P. 36A , Toner Cartridge H.P. 16A , Toner Cartridge Samsung108/104 , Toner Cartridge Samsung 1640 , Toner Cartridge Samsung 4720/1610 , Toner Cartridge Samsung 209 , Toner Cartridge Samsung 2161 , Toner Cartridge Samsung Scx 4521 Fs , Toner Canon Mf 248Dw , Toner Canon Mf 271 Dn , Hp Laser Jet M1212 Nf Mfd , Toner Canon 051 , Toner H P 77A , Toner H P 88-A , Toner Samsung 1043 , Toner Samsung 205 , Toner Canon 328 , Toner Canon 925 , Toner Cartridge Canon 326 , Toner Cartridge Samsung 101 , Toner Cartridge Samsung 116 , Toner Cartridge Canon 337 , Toner Cartridge Hp Lajer Mfp-136A , Toner Cartridge H.P. 110A , Toner Cartridge H.P. Mfd - 2606Dn , Toner Cartridge Brother- B-700D , Toner Cartridge H.P. Tower- 136A , Toner Cartridge - Canon - Image Class -Mf284dw - Cartridge- 072 , Toner Cartridge - Canon - Image Class -Mf271dn - Cartridge- 071 , Toner Cartridge - Canon - Image Class -Mf289dw , Toner Cartridge - Canon - Image Class -Mf643cdw - Cartridge- 054 (Kycm - Each) , Canon Ir 222N-Nb59 , Hp- Laser Jet -Mfp M-233Sdw , Samsung Mlt B48c602160 , Samsung Ml2161 , Samsung Ml 1640 , Samsung Scx 4521 Fs , Canon Mf 248 Dw , Canon Mf271dn , Canon Lbp 122 D , Canon Vrf 273 , Canon Mf 4820D , Canon Mf 240 4F Riit , Canon Image Class Mf 4820 D , Canon Lbp 6018 B , Canon Ic Mf 4820 D , Canon Ic 271 Dn , Canon Ic 241 Dw , Canon Image Runner 224 N , Canon Ic Lbd 122 Dw , Canon Mf 240 Series , Canon 643C Dw , Toner Cartridge 3060 , Image Class Mf 2410 , Image Class Mf 24 1 Dw , Image Class Mf-284Dw , Brother Dcp B7500d , H.P. Laser Jet Mfp M 4360N , H.P. Laser Jet Mfp 136 A , H.P. Laser Jet Tank Mfp 2606 Oix , H.P. Laser Jet M 1213 Mfd , H.P. Mf486 Dw , H.P. Toner Cartridge 158 , Toner Cartridge Brother 3060 , Toner Cartridge Hp -Mfp 436 Dn , Toner Cartridge Brother -B021 , Head Name - Photo Copy , Photo Copy On A4 Size Paper (With Min 75 Gsm Paper) , Photo Copy On A3 Size Paper (With Min 75 Gsm Paper) , Colour Printing Work On A4 Size Paper , Spiral Binding With Binding Covers A4 Size , Head Name - Rented Vehicle , Monthly Charge Of Vehicle For Maximum 800 Km (Sedan Car Of Max. Rs. 7.00 Lakh Ex Showroom Price) , Variable Charge For Journey Outside Headquarter Or Within Headquarters Beyond Maximum Limit , Head Name - Rented Cooler , Monthly Charge Of Air Cooler, Tank Capacity: 40 Ltr., Isi Marked , Monthly Charge Of Air Cooler, Tank Capacity: 75 Ltr., Isi Marked
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Madhya Pradesh View Result →
5.
Communications and Information Technology  #11272066 AOC
Bids Are Invited For General Servicing Of 1.5 Or 2.0 Tr Wac Or Sac Units - General Servicing Of 1.5/2.0 Tr Wac/Sac Units Of Different Make I/C Removing From Existing Position If Reqd., Dismentling Of Faulty Parts, Cleaning The Air Filter, Cleaning The Condesor And Evaporator Coil With Help Of Chemical Solution & Water, Lubrication Of Moving Parts, Complete Checking, Testing And Minor Faults Rectification I/C Replacement Of Knobs, Setting Of Thermostate Etc Complete As Reqd. , Sitc Of 1.5 Tr Resiprocating Type Compressor - Supply Of The 1.5 Tr Capacity New Hermatically Sealed Reciprocating Type Compressor Purchased From The Authorised Dealer I/C Dismentalling Of The Faulty Compressor From Site, To And Fro Transportation Charges For Compressor And I/T/C Of New Compressor In Place Of Faulty Compressor Of Existing Wac/Split Ac Etc Complete As Required. , Sitc Of 2 Tr Resiprocating Type Compressor - Supply Of The 2.0 Tr Capacity New Hermatically Sealed Reciprocating Type Compressor Purchased From The Authorised Dealer I/C Dismentalling Of The Faulty Compressor From Site, To And Fro Transportation Charges For Compressor And I/T/C Of New Compressor In Place Of Faulty Compressor Of Existing Wac/Split Ac Etc Complete As Required. , Sitc Of 1.5 Tr Rotary Type Compressor - Supply Of The 1.5 Tr Capacity New Hermatically Sealed Rotary Type Compressor Purchased From The Authorised Dealer I/C Dismentalling Of The Faulty Compressor From Site, To And Fro Transportation Charges For Compressor And I/T/C Of New Compressor Of Existing Wac/Split Ac Etc Complete As Required. , Charging Of Refrigerant Gas For 1.5 Tr Wac Or Split Ac - Charging Of Refrigerant Gas R-22/ 32 Upto Specified Pressure In 1.5 Tr Capacity Ac Units And Pressure Testing By Nitrogen, Vaccumisation For 2 Hours, Purging With Gas And Testing, Commissioning Of The Ac Unit Etc As Reqd. , Charging Of Refrigerant Gas For 2.0 Tr Wac Or Split Ac - Charging Of Refrigerant Gas R-22/ 32 Upto Specified Pressure In 2.0 Capacity Ac Units And Pressure Testing By Nitrogen, Vaccumisation For 2 Hours, Purging With Gas And Testing, Commissioning Of The Ac Unit Etc As Reqd. , Replacement And Reparing Of Thermostate - Replacement And Reparing Of The Thermostate In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Starting Capacitor 80 To 100 Or 120 Mfd - Replacement And Reparing Of The Starting Capacitor (80-100/120 Mfd) In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Running Capacitor 36 Or 40 Mfd - Replacement And Reparing Of The Running Capacitor (36/40 Mfd) In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Relay For Wac Or Split Ac - Replacement And Reparing Of The Relay For Wac / Split Ac In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Wiring Kit For Wac Unit - Replacement And Reparing Of The Wiring Kit For Wac Unit In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Selector Switch For Wac Unit - Replacement And Reparing Of The Selector Switch For Wac Unit In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Rewinding Of Condensor Or Blower Motor For Ac Unit Incuding Replacement Of Bush - Rewinding Of Condensor/Blower Motor For Ac Unit I/C Replacement Of Bush In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement And Reparing Of Blower Fan Motor Capacitor 4 Or 6 Mfd - Replacement And Reparing Of The Blower Fan Motor Capacitor 4/6 Mfd In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Repairing Of Pcb For Wac Or Split Remote Control Unit - Repairing Of Pcb For Wac/Split Remote Control Unit In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Replacement Of Faulty Or Irrepairable Pcb For 1.5Tr Split Ac Unit - Replacement Of Faulty / Irrepairable Pcb For 1.5Tr Split Ac Unit In The Existing Ac Units In Place Of Fulty, Fixing, The New Item And Testing, Connection Etc. Complete As Reqd. , Sitc Of Blower Fan Motor For 1.5 Or 2 Tr Window Or Split Ac - Sitc Of Blower Fan Motor For 1.5/2 Tr Window/Split Ac Unit In Lieu Of Damaged I/C Connection Etc As Reqd. , Supplying, Installation Of Condensor Or Blower Fan Blade - Supplying, Installation Of Condensor / Blower Fan Blade Same As Per Existing Pvc / Metal Blade In Lieu Of Damaged I/C Fixing The Same Etc As Req. , Top Up Or Additional Charging Of R-22 Or 32 Gas - Provision Of Top Up / Additional Charging Of R-22/32 Gas Upto Specified Pressue In Existing Window Ac / Split Ac Units I/C Flushing, Gas Charging, Testing Etc Complete As Reqd. , Supplying And Drawing Of 3X2.5 Sq. Mm Frls Pvc Copper Single Core Cable - Supplying And Drawing 3X2.5 Sq. Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing Of 6X2.5 Sq. Mm Frls Pvc Copper Single Core Cable - Supplying And Drawing 6X2.5 Sq. Mm Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of 20Mm Medium Class Pvc Conduit - Supplying And Fixing Of 20Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Fixing Of 25Mm Medium Class Pvc Conduit - Supplying And Fixing Of 25 Mm Size Of Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supplying And Fixing Dp Sheet Steel Enclosure With 25 Or 32Amps 240 Volts C Curve Dp Mcb - Supplying And Fixing Dp Sheet Steel Enclosure On Surface/ Recess Along With 25/32Amps 240 Volts C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Of 5 A To 32 A Rating, 240 Or 415 V, 10 Ka, C Curve, Spn Mcb - Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Single Pole And Neutral Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Of 3X2.5 Sq. Mm Pvc Frls Round Sheathed Multi Core Bright Annealed Bare Copper Cable - Supplying And Fixing Of 3X2.5 Sq. Mm Pvc Insulated And Frls Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cable For Voltage Grade Up To 1100 Volts As Per Is 694-1990 I/C Fixing On Wall With Suitable Clamp/Saddle Etc. Complete As Reqd. , Dismentalling Of Existing 1.5 Or 2.0 Tr Capacity Window Or Split Ac Units - Dismentalling Of Existing 1.5 / 2.0 Tr Capacity Window / Split Ac Units Along With Indoor / Outdoor Units & All Other Existing Accessories Including Disconnection Of Electrical Connection, Copper Piping, Drain Piping , Stand Etc. From Existing Location Of Te / Bts Site Under Ssa Concerned And Reparing Of Any Damage During Dismentling By Making Good The Same Etc. Complete As Reqd. , Transportation Of Existing 1.5 Or 2.0 Tr Capacity Window Or Split Ac Units - Transportation Of Existing 1.5 / 2.0 Tr Capacity Window / Split Ac Units Along With All Accessories Etc From Te / Bts Site Of Ssa Under Ba To Store / Any Place In Same Ssa As Directed By Engg. In Charge By Transport By Truck / Loading Vehicle I/C Loading, Unloading & Safe Handling Etc.Complete As Reqd. , Itc Of 1.5 Or 2.0 Tr Capacity Split Ac Units - Installation Of 1.5 / 2.0 Tr Capacity Split Ac Units With Indoor And Outdoor Unit I/C Fixing The Refrigerant Piping With Insulation, Cutting, Brazing, Laying The Cable Along With The Piping Connections, Repairing The Minor Leakages Of The Complete System I/C Testing, Commissioning Of Split Type Ac Unit Etc. Complete As Reqd. , Pdg And Fixing Of 1 By 4 Inch Dia Copper Refrigerant Piping - Pdg And Fixing 1/4 Inch Dia Copper Refrigerant Piping I/C Covering Of Copper Piping With Polystyrene Insulation I/C Cutting, Brazing, Jointing, Bends, Sockets Etc As Reqd. , Pdg And Fixing Of 5 By 8 Inch Dia Copper Refrigerant Piping - Pdg And Fixing 5/8 Inch Dia Copper Refrigerant Piping I/C Covering Of Copper Piping With Polystyrene Insulation I/C Cutting, Brazing, Jointing, Bends, Sockets Etc As Reqd. , Providing And Fixing 12 Mm Thick Particle Board - P/F 12 Mm Thick Particle Board On Surface Of Wall For Fixing The Indoor Unit Of Split Type Ac Unit Or Fixing / Covering The Extra Space Etc. With The Help Of Screw Complete Etc. As Reqd , Supplying And Fixing Suitable Size Ms Stand For Split Type Ac Outdoor Unit - S/F Suitable Size Ms Stand For Placement Of Split Type Ac Outdoor Unit Made Out Of 16 Gauge Powder Coated Ms Sheet I/C Fixing With Help Of 4 Nos. Fasteners For Grouting On Wall / Floor, Etc. Complete As Required. , Providing And Fixing 20 Mm Dia Heavy Duty Pvc Pipe For Drainage Purpose Of Ac Unit Including Connection Testing Etc As Required. - Providing And Fixing 20 Mm Dia Heavy Duty Pvc Pipe For Drainage Purpose Of Ac Unit I/C Connection, Testing Etc As Required. , Sitc Of Ac Smart Controller For 02 Nos. Ac Cyclic Operation For 4 Or 8 Hrs Duration Suitable For Working On Single Phase Ac Supply System - Sitc Of Ac Smart Controller For 02 Nos. Ac Cyclic Operation For 4/8 Hrs Duration , Suitable For Working On Single Phase Ac Supply System, Having Under Voltage & Over Voltage Tripping Facility And Selector Switch For Operation Of Cp 1/ Cp 2/ Auto Mode Etc Complete As Reqd. (Make- Bsc Or Similar Superior Make) Total Quantity : 1135
Contract Date: Ref. Documents Contract Value : 7.74 Lakh
Government Departments No of Bidders 5
6.
Educational and Research Institute #11134188 Technical Bid
structure waterproof and fire retardant international made hangar with aluminum structure having a span of 25 metres (as per onsite requirement) in width with waterproof and fire-retardant sheet (copy of certificate to be attached) should be strong enough to sustain high speed wind/rain pressure. wooden platform of 4”-9” height made with 19mm thick hard board and bed supported with providing 2”x2” wooden batons in properly leveled having no undulation, create no sound on using and covered with brand (*) new laminated carpet on complete area and 20 ceiling/pedestal fans covering the entire hangar structure. (entire ceiling and both walls from inside of both hangars should be covered with multi-colour cloth/fabric). 10 led metal lights & 50 mojo iron barricades (height 4 ft. x length 6ft.) with wheels should be provided one day before start of the book festival. auditorium (image at annexure-vi) fire retardant (certificate to be attached with tender document with validity) the flex/branding of the book festival may be affixed/provided on the hangar structures (image of hangar structure at page no. 44) as per the details given below: 1. branding on both sides of the hood (triangular shapes) of the hangar structures. 2. branding on the roof in hangar structures. 3. decoration of entry point of the structures with flowers/artificial flowers in consultation with festival/officer in-charge. the designs of the gates should be provided by the vendors for finalizing by the festival/officer in-charge. note: designs of all branding will be provided by nbt. *providing & laying on hire basis a brand new laminated carpet, non-woven needle punch carpet of genuine fiber minimum overall weight 1000 gm/ sgm (+ 5%) having minimum 3.90 mm thickness preferable containing 375 gm polyester fiber or equivalent fiber (+ 5%) and the carpet should not loss the thickness more than 25% after 1000 impact and of required shades & laying with approved adhesive or double side tape wherever required etc. as per the direction of officer-in-charge, i/c covering with polythene sheet till the inauguration of a festival. in case of dew factor, contractor should cover the entire structure of the hangars with waterproof tripal/polythene to avoid damaging of books. , stall: size 3m x 3m construction of stalls each of size 3x3mtr. with three side paneling of octonorm structure with computerized fascia of uniform colour (maximum 8 colour) with nbt logo in each and every stall on vinyl pasting in hindi/english (with flag numbering as per the image shown at annexure-v), consisting of 9 ms shelves of size 96”x8.5” with 2” depth duly powder coated in white colour, 9 led light (each of 9 watt), one octonorm table for counter of the same colour, two black cushioned chair with arms, a plug point for computer, two drinking water bottles (each of 1 ltr.) on daily basis, one small dustbin (10 ltr.) and one kanat of good quality of size 3mx3m size with provision of proper hanging system for covering/closing the stall after the book fair timings. the kanat should be made available to the participants a day before start of the book fair. laying & fixing of new brand laminated carpet(*) in the entire passage of indoor hall including the stall area, in case where structure is not required, should be provided by the contractor) , pagoda (3mtr.x3mtr.) construction of pagodas each of size 3x3mtr. on wooden platform, three side paneling of octonorm structure with computerized fascia of uniform colour (maximum 8 colour) with nbt logo in each and every pagodas on vinyl pasting in hindi/english with flag numbering as per the image shown at annexure-v in english/regional language of size 3m x3m, each with prefab octonorm system of the same colour in each stall, consisting of 9 ms shelves of size 96”x8.5” with 2” depth duly powder coated in white colour, 9 led light (each of 9 watt), one octonorm table for counter of the same colour, two black cushioned chair with arms, a plug point for computer, two drinking water bottles (each of 1 ltr.) on daily basis, one small dustbin (10 ltr.). 4mtr.x4mtr. polythene to cover the books is also required in each stall. , thematic customized gate: thematic/customized gate in line with the theme of the book fair with detailed specifications as shown and approved during digital presentation or as per designed provided by nbt. thematic gate comprises of backlit, wooden frame, mdf board. vinyl pasting and handmade painting (if required) with sufficient parco / led light. , stage: size 32’ x 20’ x 4’ in height made of wooden platform with new brand laminated synthetic carpet (*) with needle punch of blue/red color; • 1 table 20’ x 3’ with table cloth and frill in front or 10 center glass tables with side tables. • 1 lightening lamp • 15 executive wooden cushioned arm chairs with 10 side table of 3ft x 2ft size having vinyl pasting 4 side (design to be provided by nbt) • 10 standing ac tower (each of 5 ton) • 01 led screen wall (20’x8’) or as per stage requirement • 20 led parco light/ beam light (multi-colored on truss structure) for cultural events / programs & cultural • decoration of stage, entry gate & dais with fresh/artificial flowers should only be made after consulting the festival/officer in-charge • the arrangement of stairs with ramp with railings for support (both sides of stage) having vinyl pasting on 4 sides • 50 mineral water bottles (200 ml) for guests on stage, on per day basis • 10 name plates of the guests on stage as per the direction of the festival/officer in-charge. • 50 mojo barricades of 4ft. (height) x 6 ft. (width) with wheels • 2 podiums with nbt logo on sun board on three sides as per design provided by nbt 2 green room in the form of pagoda • size 6mtr.x6mtr. with three side covered with orange paneling, wooden platform with new brand laminated synthetic carpet. • 12 spot lights (9 watt each) • 4 led halogen lights (100 watt each) • 4 full length mirror with proper stand , complete pa system and stage set-up for organizing cultural / rock band programmes with operator for inaugural function and other programs along with provision of fusion and rock musical band playing for the 9 days during the book festival with two helper along with the provision of additional sound & lights as per tech rider of artists (as per the terms & conditions given at annexure-ix) a) box truss – aluminum box truss 60x40x25 with aviation grade material for safety and as per stage size (on all four sides) truss and scaffolding/speaker tower as required b). sharpy designing/pattern as per artist c) warm white led par d). blinder (4x4 motleys) e) colour led (54x3, 32x3) f). colour wash g) atomic strobe rgbw h) smoke machine high powered i) led percons j) avolite light controller/designing of lights patterns k) line array complete pa system venue suited dual, audio system (conical long throw system) – (lacoustic, jbl, dnb martin equivalent) l) bass audio subwoofer (lacoustic, jbl, dnb equivalent) m) side fill jbl, 835p n) foot monitors jbl 915 for stage angled curvature type for musicians o) 1x32 channel soundcraft mixer digital with presets and files (allen heath) p) amplifier audio digital with audio files for pa venue (crown, labgruppen, equivalent) q) amplifier crowns xti-6002 for stage r) di boxes bss/radial s) cordless mic sennheiser 945 for emeee t) shure mx series podium u) cordless shure for singer v) shure qlxd laple headset w) wired mirophones sm58 & sm57 for stage (shure/sennheiser) x) mic stand box big & small y) xlr snack long patch cord networking cabling console software laptop/playable engineer z) walkie talkie with talk back feature , announcement general pa system (digital) with 12 loudspeakers with 25–30-watt lmp and 1 standing mike (jbl/sony/phillips) for announcement purpose. , executive sofa sets (3 seater) with white covers along with 6 central tables , chairs with white cover for seat and back , wheel chair with attendant with proper uniform , queue manager , iron-ms steel barricades (size 4.5 ft. x 3 ft.) , brand new laminated carpet (*) for floor area (same specification as given for carpet in structure at s.no. 1) , tin wall covering with white color cloth with maximum height of 10 ft. , wooden platform with new laminated carpet , ground net (green) , fire fighting equipment (co2 water and powder mix with refilling dates) with one trained personnel with proper uniform for operating fire fighting equipment. , brand new dustbins (big size) plastic with cover , sweepers in proper uniform of the company for cleaning of ground are required one day before start of the book fair and till the end of the book fair (10:00 a.m. to 8:00 p.m.) , security personnel in proper security uniform and necessary equipments are required to be deployed at venue one day before start of the book fair and their after round clock till the end of the book fair: (*) rates may be given on per day basis only: a) supervisor b) guards , fresh painted steel almirah with lock and key (full size) , printing of flex & hoarding with mounting on iron frame in different locations (onsite/offsite), including gates, participants lists, backdrops, signages, etc. , vinyl digital print (3.3 ft. x 8 ft.) , pedestal / ceiling fans , wooden/steel tables 2’x5’ , selfie point on sunboard (5mm with digital vinyl print and mounting/framing) having heavy base (picture enclosed) – size: 4’x6’ and as per requirement , octonorm table for display of books , led wall screen of size 8’x12’ with masking & ramp (with operator) p5 – back support connectivity with multi cam setup, usb connectivity and laptop for insertion for av’s and tv’s, sound system and stage fold back speakers of 600 watts(2), sound mixing console and cables with wires and two power points (at the location decided by the officer-in-charge) for relay of live programme. , led screen (52 inch) — (the bazel 10m with stand and back support connectivity with multicam setup, usb connectivity and laptop for insertion for av’s & tv’s, sound system & stage fold back speakers, sound mixing console, cables with wires and 5 power points , providing of labours for routine miscellaneous work from 10:00 a.m. to 9:00 p.m. (rate may be given on per day basis) , halogen led lights of 150 watt with adjustable beam and angle complete with sufficient lighting and necessary wiring , 5 watt led coloured / decorative bulbs , silent generator set: the generator should be in operational condition one day before start of the book fair and till the conclusion of the fair. a) one 125 kva generator set (with fuel and operator) for full duration b) one 62 kva generator set (with fuel and operator) for full duration , main line connection for total job from electric and generator set sources and providing a line for connection inside the stalls of participants, illumination of main gate and toilet, area of the exhibition ground and any other area of the ground, if required with proper and sufficient supply. it shall be the duty of the contractor to get the temporary electric connection for the fair at his own cost one day before start of the book fair. the contractor shall arrange installation of the connection, tendering of security deposit etc., to government authorities at his own cost. only actual consumption charges will be reimbursed –to contractor by nbt on production of original bill by the contractor. in case of any problem for getting electric connection, it shall be the sole responsibility of the contractor to provide adequate supply through hiring more generators at his own cost one day before start of the book fair and no extra payment shall be given to contractor for hiring and providing such extra generator, if any. note : 1. providing power connection of various connected rating from switch board in various stands and with suitable size of cooper/aluminum 3½ /4 core armoured cable and earth wire controlled with suitable capacity switchgear such as ictpn, icspn/mcb i/c end termination laying of cable in floor, trench, carpets and tapping with power supply from permanent db of the ground i/c connections interconnection and maintenance during the fair period. (the cables and other wiring needs to be put under the wooden ramps/rubber covering mat etc. under the carpet on ground floor. 2. only one time payment as quoted by the tenderer will be made in case of any increase or decrease in number of stalls. , street light iron poles (20’x2-½’’) with 4 led halogen light each of 100 watt on each pole , photography per day basis (for 6 days) (photographs should be provided in the hard disk and pen drive after the book fair). 200 photographs of inauguration and other important programs are required in high resolution in coffee table album form in consultation with officer in-charge. • rate for per unit cost for 6 days (press conference + book fair) may be quoted in the financial bid/boq. • specifications for 01 unit: dslr full frame hd 4k camera with 3 cameras with photographer with each camera for 6 days. • photography + cameras would be as per onsite requirement and as per the directions of the officer in-charge. , gimbal videography per day basis (for 6 days) (all programs should be provided in hd format and high resolution. the same should be provided in hard disk & pen drive after the book fair) along with 20 minute short documentary of the programs. • rate for per unit cost for 6 days (press conference + book fair) may be quoted in the financial bid/boq. • specifications for 01 unit: 3 full hd video cameras setup with sdi output with 3 videographers with each camera for 6 days. • videography + cameras would be as per onsite requirement and as per the directions of the officer in-charge. note: provision of a professional digital video multi-camera setup for domestic book fairs, featuring broadcast-quality 1080p full hd (sdi format) production. the system includes: • three (3) full hd professional cameras with sdi output • online digital editing and production table • digital video mixer/switcher for live production • audio talkback communication system • professional audio mixer and sound equipment • on-site editing facilities • skilled technical crew, including camera operators and production personnel. this setup ensures high-quality live recording, switching, and editing suitable for professional broadcasting and online streaming requirements. , one drone camera with operator for videography of the event on day-to-day basis with on-site permission and security clearance (all coverages should be provided in hd format and high resolution. the same should be provided in hard disk & pen drive after the book fair). • rate for per unit cost for 6 days (press conference + book fair) may be quoted in the financial bid/boq. • specifications: hd format and high resolution would be as per onsite requirement and as per the directions of the officer in-charge , live streaming on social media channels with social media team of 2 members (youtube & facebook) from two locations and on digital screens as per requirement , cctv cameras with live telecast on screen (led 52”) with complete installation with a control room access note: complete footage/recording for entire event must be provided after the event to nbt in hard drive & pen drive (rates may be given for full duration) , refreshment packets 250 each per day for children/students (each packet contains – one packet of good day biscuit, one packet of britannia fruit cake, one packet of lays chips & one packet of fruity/real juice/maaza/slice , hiring of taxi (swift dzire) minimum 80 km and 12 hours duty , hiring of taxi (innova) minimum 80 km and 12 hours duty , indian flag (khadi cloth) with mounting on pole (20 feet height) with 100 watt led (4 nos.) halogen light to be focused from bottom to top , acrylic words installation with wooden base covered with cloth , thematic installation / sculpture with complete set-up: each sculpture is to be made and placed on laminated printed carpeted platform (double plywood platform/wooden platform on iron frame with laminated carpet) at ideal height as per the size and design approved in the presentation and will consist the following items: i) 4-5 parco lights ii) cloth for masking the platform from all sides iii) 5-6 queue manager , lunch/dinner (veg. thaali) on per day basis during the book fair (rates may be quoted for one thali) , lunch/dinner (veg. thaali) on per day basis during the book fair (rates may be quoted for one thali)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
7.
Educational and Research Institute #11054746 Technical Bid
Tender for Structure Waterproof And Fire Retardant International Made Hangar With Aluminum Structure Having A Span Of 50 Metres (As Per Onsite Requirement) In Width With Waterproof And Fire-Retardant Sheet (Copy Of Certificate To Be Attached) Should Be Strong Enough To Sustain High Speed Wind/Rain Pressure. The Hangar Structure Should Cover Stalls (3X3 Mtr.) Having Passage Of 3 Mtr. (At Least) In Between The Line Of Stalls With Entry And Exit Gate. Wooden Platform Of 4-9 Height Made With 19Mm Thick Hard Board And Bed Supported With Providing 2X2 Wooden Batons In Properly Leveled Having No Undulation, Create No Sound On Using And Covered With Brand (*) New Laminated Carpet (Two Colour, One For Stall And Other Colour For Passage) On Complete Area And 150 Ceiling Fans Covering The Entire Hangar Structure. One Side Of Hangar Should Be Covered With Glass Wall / Transparent Sheet As Per Requirement (Entire Ceiling And Both Walls From Inside Of Both Hangars Should Be Covered With Multi-Colour Cloth/Fabric) And Entire Hangar Structure Should Be Surrounded By Tin Wall With Blue/White Cloth (Neat And Clean) Wall (4 Sides) In Addition To Truss. 10 Led Metal Lights & 50 Mojo Iron Barricades (Height 4 Ft. X Length 6Ft.) With Wheels Should Be Provided One Day Before Start Of The Book Festival. Auditorium (Image At Annexure-Vii) Fire Retardant (Certificate To Be Attached With Tender Document With Validity) The Flex/Branding Of The Book Festival May Be Affixed/Provided On The Hangar Structures (Stall Hangar Structure And Auditorium Hangar Structure As Per The Designs Mentioned At Page No.38-39) As Per The Details Given Below: 1. Branding On Both Sides Of The Hood (Triangular Shapes) Of All Hangar Structures. 2. Branding On The Roof Of Each Hangar Structures (30Mtr.X30mtr.). 3. Branding On Left And Right Panels Of Main Entry And Exit Point. 4. Branding On Pillar At The Main Entry. 5. Decoration Of Entry Point Of The Structures With Flowers/Artificial Flowers In Consultation With Festival/Officer In-Charge. The Designs Of The Gates Should Be Provided By The Vendors For Finalizing By The Festival/Officer In-Charge. Note: Designs Of All Branding Will Be Provided By Nbt. Note: All Branding Should Be On Iron Frame Except Roof Branding). Note: Two Hoardings Of Size 20X20 Will Also Be Required Before The Start Of The Book Festival. In Case The Auditorium Is Required To Be Constructed Outside The Hangar Structure, The Wooden Platform With Brand New Synthetic Laminated Carpet (As Per The Specification Mention Below) Is Also Required In The Auditorium. *Providing & Laying On Hire Basis A Brand New Laminated Carpet, Non-Woven Needle Punch Carpet Of Genuine Fiber Minimum Overall Weight 1000 Gm/ Sgm (+ 5%) Having Minimum 3.90 Mm Thickness Preferable Containing 375 Gm Polyester Fiber Or Equivalent Fiber (+ 5%) And The Carpet Should Not Loss The Thickness More Than 25% After 1000 Impact And Of Required Shades & Laying With Approved Adhesive Or Double Side Tape Wherever Required Etc. As Per The Direction Of Officer-In-Charge, I/C Covering With Polythene Sheet Till The Inauguration Of A Festival. In Case Of Dew Factor, Contractor Should Cover The Entire Structure Of The Hangars With Waterproof Tripal/Polythene To Avoid Damaging Of Books. Please Note: Apart From, The Entire Hangar Structures Along With All Stalls/Pagodas Should Be Covered With Fire Retardant/Prevention Solution Spray To Avoid Any Incident To Be Occurred Due To Fire. A Certificate Of The Authorized Agency(S) Of The Concerned State For The Above Work Is Also Required To Be Submitted To The Officer In-Charge Of The Festival A Day Before Start Of The Book Festival. , Stall: Size 3M X 3M: Stall Should Be Covered With Three Side Orange/Maroon Octonorm Paneling (Size 3.3 Ft. X 8 Ft.) With Computerized Vinyl Pasting Of Name Fascia In English & Hindi Language (With Flag Numbering As Per The Image Shown At Annexure-V), Each With Prefab Octonorm System Of The White Colour In Each Stall, Consisting Of 9 Ms Shelves Of Size 96X8.5 With 2 Depth Duly Powder Coated In White Colour, 9 Led Light (Each Of 9 Watts), One Octonorm Table For Counter Of The Same Colour, Two Black Cushioned Chair With Arms, A Multi-Plug Point (Four Points) For Computer With 20 annual periodical maintenance Socket With Switch, One Mayur Jug With Cold Water Facility (20 Ltr.) On Per Day Basis / 02 Litr. Drinking Water Bottle (Two) On Per Day Basis In Each Stall As Per The Direction Of The Officer In-Charge, One New Dustbin And One Dark Blue Curtain (Cotton Fabric) With Uniform Colour With Provision Of Fastening And Covering The Stalls Of Equivalent Size (3Mtrx3mtr = 9 Sqm). The Curtain Should Be Made Available To The Participants A Day Before Start Of The Book. 4Mtr.X4mtr. Polythene To Cover The Books Is Also Required In Each Stall. Laying & Fixing Of New Brand Laminated Carpet (*) In The Entire Passage Of Hangar Structure Including The Stall Area Should Be Provided By The Contractor , Kashmiri Hangar (AuthorS Corner): Following Items Will Be Required In AuthorS Corner: I) Stage: Size 24 X 20 X 2 In Height Made Of Wooden Platform With New Brand Laminated Synthetic Carpet (*) With Needle Punch Of Blue/Red Color. Ii) 50 Mineral Water Bottles (200 Ml) For Guests On Stage, On Per Day Basis. Iii) 1 Podiums With Nbt Logo On Sun Board On Three Sides As Per Design Provided By Nbt. Iv) 06 Executive Wooden Cushioned Arm Chairs With 03 Centre Glass Tables And Side Tables. V) 01 Led Screen Wall (8X12) Or As Per Stage Requirement Vi) 15 Ceiling Fan. , Pagoda (3Mtr.X3mtr.) Pagoda Structure On Wooden Platform With Covering Of Synthetic Needle Punch With New Laminated Carpet Of Good Quality Having Covered With Three Side Orange/Maroon Octonorm Paneling (Size: 3.3Ft. X 8 Ft.) With Computerized Vinyl Pasting Of Name Fascia In English & Hindi Language (With Flag Numbering As Per The Image Shown At Annexure-V Of Tender), Each With Prefab Octonorm System Of The White Colour In Each Stall, Consisting Of 9 Ms Shelves Of Size 96X8.5 With 2 Depth Duly Powder Coated In White Colour, 9 Led Light (Each Of 9 Watts), One Octonorm Table For Counter Of The Same Colour, Two Black Cushioned Chair With Arms, A Multi-Plug Point (Four Points) For Computer With 20 annual periodical maintenance Socket With Switch, One Mayur Jug With Cold Water Facility (20 Ltr.) On Per Day Basis / 02 Litr. Drinking Water Bottle (Two) On Per Day Basis In Each Stall As Per The Direction Of The Officer In-Charge, One New Dustbin And One Kanat Of Good Quality Of Size 3Mx3m Size With Provision Of Proper Hanging System For Covering/Closing The Stall After The Book Festival Timings. The Kanat Should Be Made Available To The Participants A Day Before Start Of The Book Festival. 4Mtr.X4mtr. Polythene To Cover The Books Is Also Required In Each Stall. Laying & Fixing Of New Brand Laminated Carpet (*) In The Entire Passage Of Hangar Structure Including The Stall Area Should Be Provided By The Contractor. , Canopy: Size: 3Mtr.X3mtr. With 3 Side Cover, Clear Height: 7 Feet, Full Height Till Dome: 10 Feet, Colour-White, A Multi-Plug Point (Four Points) For Computer With 20 annual periodical maintenance Socket With Switch And 1 Halogen Light Of 100 Watt, 4 Visitor Chairs And 1 Round Table (Top 4Ft.X4ft.) With Legs (Height 30 Inches) And Fascia Name. The Canopy Contains 3 Removable Side Walls, Can Install And Disassemble As Needed. , Thematic Customized Gate: Thematic/Customized Gate In Line With The Theme Of The Book Fair With Detailed Specifications As Shown And Approved During Digital Presentation Or As Per Designed Provided By Nbt. Thematic Gate Comprises Of Backlit, Wooden Frame, Mdf Board. Vinyl Pasting And Handmade Painting (If Required) With Sufficient Parco / Led Light. , Stage: Size 48 X 24 X 4 In Height Made Of Wooden Platform With New Brand Laminated Synthetic Carpet (*) With Needle Punch Of Blue/Red Color; • 1 Table 20 X 3 With Table Cloth And Frill In Front Or 10 Center Glass Tables With Side Tables. • 1 Lightening Lamp • 15 Executive Wooden Cushioned Arm Chairs With 10 Side Table Of 3Ft X 2Ft Size Having Vinyl Pasting 4 Side (Design To Be Provided By Nbt) • 10 Standing Ac Tower (Each Of 5 Ton) • 10 Ceiling Fan • 01 Led Screen Wall (40X12) Or As Per Stage Requirement • 20 Led Parco Light/ Beam Light (Multi-Colored On Truss Structure) For Cultural Events / Programs & Cultural • Decoration Of Stage, Entry Gate & Dais With Fresh/Artificial Flowers Should Only Be Made After Consulting The Festival/Officer In-Charge • The Arrangement Of Stairs With Ramp With Railings For Support (Both Sides Of Stage) Having Vinyl Pasting On 4 Sides • 100 Mineral Water Bottles (200 Ml) For Guests On Stage, On Per Day Basis • 20 Name Plates Of The Guests On Stage As Per The Direction Of The Festival/Officer In-Charge. • 50 Mojo Barricades Of 4Ft. (Height) X 6 Ft. (Width) With Wheels • 2 Podiums With Nbt Logo On Sun Board On Three Sides As Per Design Provided By Nbt 2 Green Room In The Form Of Pagoda • Size 6Mtr.X6mtr. With Three Side Covered With Orange Paneling, Wooden Platform With New Brand Laminated Synthetic Carpet. • 12 Spot Lights (9 Watt Each) • 4 Led Halogen Lights (100 Watt Each) 4 Full Length Mirror With Proper Stand Truss Structure From Main Gate To Main Stage With Decoration Of Multi-Colour Paper Streamer/Cloth On Passage Area With 3D Images Of Both Side Printed & Laminated Book Covers As Per The Design Shown At Annexure-Xi (Approx 1500 Sqmtr.) , Complete Pa System And Stage Set-Up For Organizing Cultural / Rock Band Programmes With Operator For Inaugural Function And Other Programs Along With Provision Of Fusion And Rock Musical Band Playing For The 9 Days During The Book Festival With Two Helper Along With The Provision Of Additional Sound & Lights As Per Tech Rider Of Artists (As Per The Terms & Conditions Given At Annexure-Viii) Box Truss - Aluminum Box Truss 60X40x25 With Aviation Grade Material For Safety And As Per Stage Size (On All Four Sides) Truss And Scaffolding/Speaker Tower As Required Sharpy Designing/Pattern As Per Artist Warm White Led Par Blinder (4X4 Motleys) Colour Led (54X3, 32X3) Colour Wash Atomic Strobe Rgbw Smoke Machine High Powered Led Percons Avolite Light Controller/Designing Of Lights Patterns Line Array Complete Pa System Venue Suited Dual, Audio System (Conical Long Throw System) - (Lacoustic, Jbl, Dnb Martin Equivalent) Bass Audio Subwoofer (Lacoustic, Jbl, Dnb Equivalent) Side Fill Jbl, 835P Foot Monitors Jbl 915 For Stage Angled Curvature Type For Musicians 1X32 Channel Soundcraft Mixer Digital With Presets And Files (Allen Heath) Amplifier Audio Digital With Audio Files For Pa Venue (Crown, Labgruppen, Equivalent) Amplifier Crowns Xti-6002 For Stage Di Boxes Bss/Radial Cordless Mic Sennheiser 945 For Emeee Shure Mx Series Podium Cordless Shure For Singer Shure Qlxd Laple Headset Wired Mirophones Sm58 & Sm57 For Stage (Shure/Sennheiser) Mic Stand Box Big & Small Xlr Snack Long Patch Cord Networking Cabling Console Software Laptop/Playable Engineer Walkie Talkie With Talk Back Feature , Foh Console 24 Channels (Yamaha/Avid S6l) With Required Connecting Cables For Equipment With 6 Cordless Mike (Along With Operator) , Announcement General Pa System (Digital) With 12 Loudspeakers With 25-30-Watt Lmp And 1 Standing Mike (Jbl/Sony/Phillips) For Announcement Purpose , Executive Sofa Sets (3-Seater) With White Cover And 1 Central Table , Executive Sofa Sets (2-Seater) With White Cover And 1 Central Table , Executive Sofa Sets (1-Seater) With White Cover And 1 Central Table , Chairs With White Cover For Seat And Back , Wheel Chair With Attendant With Proper Uniform , Queue Manager , Brand New Laminated Carpet (*) For Floor Area (Same Specification As Given For Carpet In Structure At S.No. 1) , Brand New Ribbed Laminated Carpet , Standing Air Conditioner (Tower) - 2.5 Ton , Wooden Platform (4 To 9 Height) With New Laminated Carpet , Iron Pole (Height 20) With 10 Led Lights Each Of 200 Watt To Be Fixed On Different Locations , Fire Fighting Equipment (Co₂ Water And Powder Mix With Refilling Dates) With One Trained Personnel With Proper Uniform For Operating Fire Fighting Equipment. , Brand New Dustbins (Big Size) Plastic With Cover , Supervisor With Sweepers For Cleaning Of Ground Are Required One Day Before Start Of The Book Festival And Till The End Of The Festival (10:00 A.M. To 8:00 P.M.) Supervisor Sweepers , Supervisor With Security Personnel In Proper Security Uniform And Necessary Equipments Are Required To Be Deployed At Venue One Day Before Start Of The Book Festival And Thereafter Round The Clock Till The End Of The Book Festival: Supervisor [Preferably Ex-Serviceman (Age Below 50 Years) Or Well Experienced Security Person Below The Age Of 45 Years] - Rates May Be Given For One Supervisor For 24 Hours Duty (For 10 Days) Guards (Well Experienced Security Person Below The Age Of 40 Years) - Rates May Be Given For One Guard For 24 Hours Duty (For 10 Days) , Fresh Painted Steel Almirah With Lock And Key (Big) , Fresh Painted Steel Almirah With Lock And Key (Small) , Flex Printing Without Framing & Mounting , Printing Of Flex & Hoarding With Mounting On Iron Frame In Different Locations (Onsite/Offsite), Including Gates, Participants Lists, Backdrops, Signages, Etc. , Vinyl Digital Print (3.3 Ft. X 8 Ft.) , Sunboard (5Mm) - As Per Requirement , Selfie Point On Sunboard (5Mm With Digital Vinyl Print And Mounting/Framing) Having Heavy Base (Picture Enclosed) - Size: 4X6 And As Per Requirement , Pedestal Fan/Ceiling Fan , Maroon Octonorm Panels/Walls (1Mtr.) With Frame (8 Ft. Height) , Orange Coloured Octonorm Panels/Walls (1Mtr.) With Frame (8 Ft. Height) , Led Spot Light (9 Watt) , Octonorm Table , Black Cushioned Chair , A Multi-Plug Point (Four Points) For Computer With 20 annual periodical maintenance Socket With Switch , Dark Blue Curtain (Cotton Fabric) With Uniform Colour With Provision Of Fastening And Covering The Stalls Of Equivalent Size (3Mtrx3mtr = 9 Sqm) , Green Net , Tea/Coffee Vending Machine With Sugar/Milk/Tea/Disposable Medium Size Cup With Trained Operator For Preparing Tea/Coffee For The Guests During The Entire Period Of The Festival (300 Cup Per Day Basis) , Wooden/Steel Tables 2X5 With Frill , Pagoda (5Mtr.X5mtr.) With 2 Tables, 2 Chair, 2 Electric Points And 1 Halogen Light Of 100 Watt With Fascia Name , Pagoda (3Mtr.X3mtr.) With 1 Table, 2 Chair, 2 Electric Points And 1 Halogen Light Of 100 Watt With Fascia Name , Door With Proper Lock And Key System , Led Wall Screen Of Size 8X12 Or As Per Requirement With Masking & Ramp (With Operator) P5 - Back Support Connectivity With Multi Cam Setup, Usb Connectivity And Laptop For Insertion For AvS And TvS, Sound System And Stage Fold Back Speakers Of 600 Watts (2), Sound Mixing Console And Cables With Wires And Two Power Points (At The Location Decided By The Officer-In-Charge) For Relay Of Live Program. , Mojo Iron Barricades (Height 4 Ft. X Length 6Ft.) With Wheel - As Per Onsite Requirement/As Per Directions Of The Officer In-Charge , Led Tv (52 Inch) - (The Bazel 10M With Stand And Back Support Connectivity With Multi-Cam Setup, Usb Connectivity And Laptop For Insertion For AvS & TvS, Sound System & Stage Fold Back Speakers, Sound Mixing Console, Cables With Wires And 5 Power Points , Providing Of Labour For Routine Miscellaneous Work From 10:00 A.M. To 9:00 P.M. (Rate May Be Given On Per Day Basis) , Branded Desktop Computer System With Good Configuration (Core I5-4Th Processor/Ddr3 16Gb Ram/512Gb Ssd/Gt 730 4Th Gb Graphics/19 Inch Hd Led Monitor/Keyboard/Mouse/Window10/Wi-Fi , 3 In 1 Laser Printer With Cartridge, Scanner & Photocopier With A-4 Size Paper Ream (Hp/Canon) , Lease Line With Wi-Fi Internet Connection Having 500 Mbps With Proper Distribution At 10 Different Locations , Halogen Led Lights Of 200 Watt With Adjustable Beam And Angle Complete With Sufficient Lighting And Necessary Wiring , 5-Watt Led Colored / Decorative Bulbs , Tungsten Outdoor Warm Lighting For Decoration On Trees , Silent Generator Set: The Generator Should Be In Operational Condition One Day Before Start Of The Book Festival And Till The Conclusion Of The Festival. One 125 Kva Generator Set (With Fuel And Operator) For Full Duration One 62 Kva Generator Set (With Fuel And Operator) For Full Duration , Main Line Connection For Total Job From Electric And Generator Set Sources And Providing A Line For Connection Inside The Stalls Of Participants, Illumination Of Main Gate And Toilet, Area Of The Exhibition Ground And Any Other Area Of The Ground, If Required With Proper And Sufficient Supply. It Shall Be The Duty Of The Bidder To Get The Temporary Electric Connection For The Festival At His Own Cost One Day Before Start Of The Book Festival. The Bidder Shall Arrange Installation Of The Connection, Tendering Of Security Deposit Etc., To Government Authorities At His Own Construction Only Actual Consumption Charges Will Be Reimbursed To The Bidder By Nbt On Production Of Original Bill. In Case Of Any Problem For Getting Electric Connection, It Shall Be The Sole Responsibility Of The Bidder To Provide Adequate Supply Through Hiring More Generators At His Own Cost One Day Before Start Of The Book Festival And No Extra Payment Shall Be Given To Bidder For Hiring And Providing Such Extra Generator, If Any. Note : 1. Providing Power Connection Of Various Connected Rating From Switch Board In Various Stands And With Suitable Size Of Cooper/Aluminum 3½ /4 Core Armored Cable And Earth Wire Controlled With Suitable Capacity Switchgear Such As Ictpn, Icspn/Mcb I/C End Termination Laying Of Cable In Floor, Trench, Carpets And Tapping With Power Supply From Permanent Db Of The Ground I/C Connections Interconnection And Maintenance During The Festival Period. (The Cables And Other Wiring Need To Be Put Under The Wooden Ramps/Rubber Covering Mat Etc. Under The Carpet On Ground Floor. 2. Only One Time Payment As Quoted By The Tenderer Will Be Made In Case Of Any Increase Or Decrease In Number Of Stalls. , Street Light Iron Poles (20X2-½) , Photography For 10 Days (Photographs Should Be Provided In The Hard Disk And Pen Drive After The Book Festival). 200 Photographs Of Inauguration And Other Important Programs Are Required In High Resolution In Coffee Table Album Form In Consultation With Officer In-Charge. • Rate For Per Unit Cost For 10 Days (Press Conference + Book Festival) May Be Quoted In The Financial Bid/Boq. • Specifications For 01 Unit: Dslr Full Frame Hd 4K Camera With Minimum 3 Cameras With Photographer With Each Camera For 10 Days. • Photography + Cameras Would Be As Per Onsite Requirement And As Per The Directions Of The Officer In-Charge. , Videography For 10 Days (All Programs Should Be Provided In Hd Format And High Resolution. The Same Should Be Provided In Hard Disk & Pen Drive After The Book Festival) Along With 20 Minute Short Documentary Of The Programs. • Rate For Per Unit Cost For 10 Days (Press Conference + Book Festival) May Be Quoted In The Financial Bid/Boq. • Specifications For 01 Unit: 3 Full Hd Video Cameras Setup With Minimum 3 Videographers With Each Camera For 10 Days. • Videography + Cameras Would Be As Per Onsite Requirement And As Per The Directions Of The Officer In-Charge , One Drone Camera With Operator For Videography Of The Event On Day-To-Day Basis With On-Site Permission And Security Clearance (All Coverages Should Be Provided In Hd Format And High Resolution. The Same Should Be Provided In Hard Disk & Pen Drive After The Book Festival). • Rate For Per Unit Cost For 10 Days (Press Conference + Book Festival) May Be Quoted In The Financial Bid/Boq. • Specifications: Hd Format And High Resolution Would Be As Per Onsite Requirement And As Per The Directions Of The Officer In-Charge , Live Streaming On Social Media Channels With Social Media Team Of 2 Members (Youtube & Facebook) , Cctv Cameras With Live Telecast On Screen (Led 52) With Complete Installation With A Control Room Access Note: Complete Footage/Recording For Entire Event Must Be Provided After The Event To Nbt In Hard Drive & Pen Drive (Rates May Be Given For Full Duration) , Hiring Of Taxi (Swift Dzire) Minimum 80 Km And 12 Hours Duty , Hiring Of Taxi (Innova) Minimum 80 Km And 12 Hours Duty , Digital Kiosk Of Latest Version (Android With Touch Screen) , Indian Flag (Khadi Cloth) With Mounting On Pole (20 Feet Height) With 100 Watt Led (4 Nos.) Halogen Light To Be Focused From Bottom To Top , Round Table (Top 4Ft.X4ft.) With Legs (Height 30 Inches) With Frill , Vvip Lounge Consisting Of The Following (Specification As Per Images Enclosed At Annexure Viii) - As Per Onsite Requirement/As Per Directions Of The Officer In-Charge: • Size - 90-100 Sq. Mtr. Or As Per Onsite Requirement • 3 Sofa Three Seater With White Cover/Cloth • 2 Sofa Two Seater With White Cover/Cloth • 5 Glass Central Table • 5 Dustbins, Each Of 20 Litre • Attached Washroom 6 X 16 (Western Washroom Fittings) • 10 Multi-Plug Points (With Four Points) For Computer With 20 annual periodical maintenance Socket With Switch • 20 Led Light • 4 Tower Air Conditioner 5 Ton (Each Cottage) • 10 Vip Chairs • 2 Big Almirahs • Photo Frame - 2 Ft. X 4 Ft. (Image Will Be Provided By Nbt) • 5 Pedestal Fans • 5 Ceiling Fans • 4 Insect Killer With Aluminium Body - Fly Catcher Machine (30 Watt) • Led Tv (52 Inch) - (The Bazel 10M With Stand And Back Support Connectivity With Multi-Cam Setup, Usb Connectivity And Laptop For Insertion For AvS & TvS, Sound System & Stage Fold Back Speakers, Sound Mixing Console, Cables With Wires And 5 Power Points For Relay Of Live Programme , Thematic Installation / Sculpture With Complete Set-Up: Each Sculpture Is To Be Made And Placed On Carpeted Platform (Wooden Platform & Carpet) At Ideal Height As Per The Size And Design Approved In The Presentation And Will Consist The Following Items: I) 4-5 Parco Lights Ii) Cloth For Masking The Platform From All Sides Iii) 5-6 Queue Manager , Acrylic Words Installation On Wooden Base Platform With Carpet , Lunch/Dinner (Veg. Thaali Containing Jeera Rice, Sabji, Dal, Chapati- 04, Raita/Curd, Paneer, Salad & Sweet Etc.) , Brand New Dustbins (120 Ltr ) Plastic With Cover As Per The Image Attached. , Pvc White Or Coloured Sky Advertising Balloon, 0.33 Mm, Size 15X15 Ft. (As Per Image Shown At Annexure-Xiii)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Jammu And Kashmir View Result →
8.
Public Administrative Department #10852137 Technical Bid
Tender For Supply, Installation And Commissioning Of Machinery For Shree Saibaba I.T.I, Shirdi. Tools, Equipment, Instrument List (As Per New Syllabus -All Trade) 1) Trade- Fitter , Pipe Cutter 6 To 25Mm Wheel Type Make - Stanley/ Ingco/Taparia / Bharat /Jk , Pipe Bender Spool Type Up To 25.Mm With Stand Manually Operated Make - Beekay / Breeze /Indar/ Voltz /Stanley , Ss And Sc Centre Lathe (All Geared) With Minimum Centre Height 6/150 Mm & Center Distance 1000 Mm Along With 3, 4 Jaw Chuck, Auto Feed System, Coolant Arrangement, Lightening Lamp, Taper Turning Attachment, Safety Guard & Standard Accessories. Make - Kirloskar / Hmt / S Micrometric , Drilling Machine Pillar Sensitive 0-20 Mm Capacity With Swivel Table Motorize With Chuck & Key Make - Panchal / Skp / Eifco /Makita , Drilling Machine Bench Sensitive 0-12 Mm Capacity With Motorize With Chuck & Key Make -Panchal /Skp / Eifco / Makita , Compressor Unit:- Suitable For Pressure - 8 Bar, Delivery-50Lpm Or More, Receiver Capacity-24 Liters Or More, 250V,50 Hz, With Pressure Regulator And Water Separator Make - Fuji / Air Master/ Elgi/Ingersol Rand , Pneumatic Trainer Kit, Each Consisting Of The Following Matching Components And Accessories. Single Acting Cylinder- Max. Stroke Length 50Mm, Bore Dia 20Mm - 1 No. Make - Extreme / Genitic / Parker / Koganei , (Ii) Double Acting Cylinder - Max.Stroke Length 100Mm, Bore 20Mm, Magnetic Type - 1 No. , (Iii) 3/2 Way Valve Manually-Actuated, Normally Closed. - 2 Nos. , (Iv) 3/2- Way Valve Pneumatically-Actuated Spring Return 1 No. , (V) One Way Flow Control Valve - 02 Nos. , (Vi) 5/2-Way Valve With Manually-Operated Switch-1No. , (Vii) 5/2 Way Valve-Pneumatically Actuated Spring Returns. , Viii) 5/2 Way Pneumatic Actuated Valve Double Point-1 , (Ix) 3/2 Way Roller Lever Valve Direct Actuation Normally Closed. - 02 Nos. , (X) Shuttle Vale - 01 No. , (Xi) Two Pressure Valve (And) - 01 No. , (Xii) Pressure Gauge 0-16 Bar - 01 No. , (Xiii) Manifold With Self-Closing Nrv-6 Way - 01 No. , (Xiv) Push Button Station For Electrical Single Point With 3 Illuminated Momentary-Contact Switch (1No + 1 Nc) And 1 Illuminated Contact Switch (1No+1Nc), Contact Load 2 A.- 01 No. , (Xv) Relay Station- With 3 Relay Each With 4 Contact Set (3No + 1Nc) Or Change Over Type, 5 A. - 01 No. , (Xvi) 3/2 Way Single Solenoid Valve With Led - 01 No., , (Xvii) 5/2 Way Single Solenoid Valve With Manual Override And Led - 01 No. , (Xviii) 5/2 Way Double Solenoid Valve With Manual Override And Led - 01 No. , (Xix) Power Supply Unit - Input Voltage 85-265V Ac, Output Voltage; 24V Dc, Out Put Current-Max.4.5A., Short Circuit Proof. - 01No. , (Xx) Profile Plate, Anodized Aluminum. 1100X700Mm. With Carriers, Maintenance Of Punting Frames And Mounting Accessories (Tube Fitted On To The Pneumatic Workstation. - 01 Set , Pneu, Matic Workstation With 40 Square Mm Aluminum Profile Legs, Wooden Work Surface, And One Pedestal Drawer Unit Having 5 Drawers, Each With Handle And Individual Locks, On Metallic Full, Panel Drawer Slide , (1) Work Table Size 1200Mm (L) X900Mm (W) X900Mm. (H), With Four Custard Wheel Including Two Lockable Wheel At The Front Side. , Drawer Size - L 460 Mm X W 495Mm. X H 158Mm. Each And Overall Size Of Drawer Unit (Apex) L 470Mm X W 495Mm X H 825Mm , (3) Drawer Slide Height (Apex) 85Mm. , Carrier For Mounting Components, Such As Pb & Relay Boxes. Cut Section Model For Pneumatic Components. , Hydraulic Trainer Kit, Each Consisting Of The Following Matching Components And Accessories Make - Hitachi / /Tecno / Power Tech / Cad Mech Engineering / Equator Hydraulic , 1) Hydraulic Power Pack: - With (1) External Gear Pump Having A Delivery Rate Of 2.5 Improvement (Apex) (A) 1400 Rpm Operating Pressure 60 Bar, Coupled To A Single-Phase Ac Motor (230V Ac) Having Starter Capacitor And On/Off Switch And Overload Protection, , 2) Pressure Relief Valve Adjustable From 0-60 Bar , 3) Oil Reservoir, 5 Liters Capacity Having Sight Glass, Drain Screw, Air Filter And P And T Ports. - 01 No. , Ii) Pressure Relief Valve Pilot Operated - 01 No. , Iii) Drip Tray, Steel 1160Mmx760Mm. - 01 No. , Iv) Pressure Gauge Glycerin- Damped, Indication Range Of 0-100 Bar. - 01 No. , (V) Four-Way Distributor With Five Ports, Equipped With A Pressure Gauge. - 01 No. , (Vi) Double Acting Hydraulic Cylinder With A Control Cam, Piston Diameter 16Mm.,Piston Rod Diameter 10Mm,Stroke Length 200Mm. - 01 No. , (Vii) Suitable Weight For Vertical Loading Of Hydraulic Cylinder - 01 No. , (Viii) Mounting Kit For Weight For Realizing Pulling And Bushing Lead. - 01 No. , (Ix) 3/2 Way Directional Control Valve With Hand Lever Actuation - 01 No. , (X) 4/2 Way Directional Control Valve With Hand Lever Actuation - 01 No. , (Xi) 4/3 Way Directional Control Valve. Closed-Center Position, With Hand Lever Actuation - 01 No. , (Xii) Non Return Valve - 01 No. , (Xiii) Pilot Operated Check Valve Pilot To Open -01 No , (Xiv) One Way Flow Control Valve With Integrated Check Valve. - 01 No. , (Xv) T-Connector With Self-Sealing Coupling Nipples (2 Nos.) And Quick Coupling Socket (1 No.) - 02 Nos. , (Xvi) Profile Plate: - Anodized Aluminum, 100X700Mm With Carriers, Mounting Frames And Mounting Accessories (To Be Fitted Onto The Hydraulic Work Station. - 01 Set , Hydraulic Work Station With 40 Square Mm. Aluminum Profile Legs, Wooden Work Surface, And One Pedestal Drawer Unit Having 5 Drawers, Each With Handles And Individual Locks, On Metallic Full Panel Drawer Slide. , (1) Work Table Size (Apex) L1200Mm. X W900Mm. Xh900Mm. With Four Castor Wheel Including Two Locale Wheel At The Front Side. , Drawer Size (Apex) L460 Mm X W495Mm. X H158Mm Each, And Overall Size Of Drawer Unit (Apex). L470Mm X W495Mm. X H825Mm. , (3) Drawer Slide Height (Apex) 85Mm. Cut Section Models For Hydraulic Components. , D.C. Shunt Generator With Control Panel,2.5 Kw, 220V & 3 Phase Squirrel Cage Induction Motor, 5 Hp,440V With Control Panel & Star Delta Starter 1) Dc Generator Make - Crompton / Bharat Ele. Motor/ Kirloskar / Electronech / Power Way Systems 2) 3- Phase Induction Motor Make - 1. Crompton 2. Siemens,3. Hindustan Electric Motor. 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Motor-Generator (Ac To Dc) Consisting Of : Squirrel Cage Induction Motor With Star Delta Starter And Directly Coupled To Dc Shunt Generator And Switch Board Mounted With Regulator, Air Breaker, Ammeter, Voltmeter, Knife Blade Switches And Fuses, Set Complete With Case Iron And Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Induction Motor Rating ;- 7.5 Hp, 415V, 50 Cycles, 3Phase Dc Shunt Generator Rating ;- 5Kw,440V (Output Voltage Varies 110-440V) 1) Dc Generator Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) 3- Phase Induction Motor Make - 1. Crompton 2. Siemens,3. Hindustan Electric Motor. 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Series Motor Coupled With Control Panel Including Spring Balance Load 2.5 Kw; 220Volts 1) Dc Series Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Shunt Motor Control Panel Including Spring Balance Load 2.5 Kw; 220Volts 1) Dc Series Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Compound Motor With Control Panel Including Spring Balance Load, Starter And Switch- 2.5 Kw, 220Volts 1) Dc Compound Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Motor Generator(Dc To Ac) Set Consisting Of - Shunt Motor With Starting Compensator And Switch Directly Coupled To Ac Generator With Exciter And Switch Board Mounted With Regulator, Breaker, Ammeter, Voltmeter Frequency Meter, Knife Blade Switch And Fuses Etc. Set Complete With Cast Iron Bed Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Shunt Motor Rating: - 5Hp, 440V, A.C., Generator Rating: - 3-Phase, 4-Wire, 3 Kva, 400/230 Volts, 0.8Pf, 50Cycles. 1) Dc Shunt Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) A. C. Generator Make - 1. Kirloskar 2. Crompton, 3. Siemens / Abb 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Ac Squirrel Cage Motor With Star Delta Starter And Triple Pole Iron Clad Switch Fuse With Mechanical Loa,5 Hp,3-Phase ,415 Volts, 50 Hz 1) Ac Squirrel Cage Motor Make - 1. Crompton, 2. Siemens, 3. Hindustan Elec. Motor /Abb / Siemens / Bbl 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Ac Phase-Wound Slip Ring Motor With Control Panel ,Starter And Switch 5 Hp, 440 V, 3-Phase, 50 Hz 1) Ac Phase-Wound Slip Ring Motor Make - 1. Crompton, 2. Siemens, 3. Havells Motor /Abb / Simens / Bbl 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard , Universal Motor With Control Panel, Starter/Switch 240 Volt, 50 Hz, 1 Hp 1) Universal Motor Make - 1. Crompton Greaves, 2. Hindustan Motor /Agni Motors / Integrated Elect Construction Of 3. Siemens / Bosch Power Tool 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Synchronous Motor With Control Panel Accessories. Like Starter, Excitation Arrangements,-3 Phase, 3 Hp, 440V, 50Hz, 4 Pole, 1) Synchronous Motor Make - 1. Kirloskar, 2. Crompton, 3. Siemens / Abb 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Thyristor /Igbt Controlled D.C. Motor Drive With Tacho-Generator Feedback Arrangement 1 Hp (Complete Set) 1)Thyristor /Igbt Controlled D.C. Motor Drive Make - 1. Crompton Greaves 2. Siemens, 3. Electro Plasto Control (Epc) /Abb / Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Thyristor / Igbt Controlled A.C. Motor Drive With Vvvf Control 3 Phase, 2 Hp (Complete Set) 1) Thyristor /Igbt Controlled A .C. Motor Drive Make - 1. Crompton Greaves 2. Siemens, 3. Electro Plasto Control (Epc) /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Single Phase Transformer, Core Type, Air Cooled, 1 Kva , 240/415 V, 50 Hz Make - 1. Siemens India 2. Kirloskar Electric Company Ltd 3. Bharat Heavy Electrical / Technovision Energy /Servokon /Sahara , Three Phase Transformer, Shell Type, Oil Cooled With Delta / Star 3 Kva , 415/240 V, 50 Hz Make - 1. Siemens India 2. Kirloskar Electric Company Ltd 3. Bharat Heavy Electrical / Servocon / Kay Pee , Electrical Machine Trainer - Suitable For Demonstrating The Construction And Functioning Of Different Types Of Dc Machines And Ac Machines (Single Phase And Three Phase). Should Be Fitted With Friction Brake Arrangement, Dynamo Meter, Instrument Panel And Power Supply Unit. 1) Dc Machines And Ac Machines Make - 1. Crompton 2. Kirloskar, 3. Siemens / Kitek Technology /Anshuman Tech 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Diesel Generator Set With Change Over Switch, Over Current Breaker And Water/ Air-Cooled With Armature, Star-Delta Connections Ac 3 Phase, 7.5 Kva, 415 Volt Or Higher Rating Make - 1. Kirloskar 2. Cummins 3. Mahindra Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Pillar Electric Drill Machine Motorized 12-20Mm. Capacity, 1 Hp,440V,3 Phase, Induction Motor With Dol Starter, Bench Type 1) Electric Motor -1. Crompton 2. Kirloskar 3. Siemens 2) Drill Machine Piller - 1. Prakash Engitech Pvt. Ltd. 2. Sri Vigneshwara Machine Tools. 3. Yogi Machine Tools / Itco Engg/ Liberty Metal /Jeet Machine , A.C. Series Type Motor With Control Panel 1 Hp, 240 V, 50 Hz 1) A.C. Series Type Motor Make - 1. Crompton 2. Kirloskar,3. Siemens /Abb / 2) Control Panel- Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Single Phase Capacitor Motor With Control Panel , Starter Switch 1 Hp 240 Volt 50 Hz 1) Single Phase Capacitor Motor Make - 1. Crompton Greaves 2. Hindustan Motors 3. Siemens Motors / Kirloskar 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Manual Motor Coil Winding Machine - With Step Arbour Make - 1. Chawla And Chudhari Trading Co. Pvt 2. Bgi Tools And Machine 3. Shree Esha Winding Technology / Sigva / Signatt / Heaven , Ceiling Fan Coil Winding Machine - 250V,50Hz, 1- Phase With Speed Control Make - 1. Bharat Machine Tools Ind. 2. Nishan Electric 3. Jangir Engineering Work / Kisan Engg / Nilkanth Electric , Primary Current Injection Set 220V,50Hz, 1-Phase,Output Current-200A(Min) With Timer Make - 1. Sb Electro Tech. 2. Pragati Process Controls, 3. Scope T&M Pvt / Udeytaj Electric / Motwane /Kpm Engg , Stepper Motor With Digital Controller Make - 1. Ajanta Export Industries. 2. Anubhuti Power System 3. Bombay Electronics 4. Siemens 5. Schneider Elect 6. Abb , Shaded Pole Motor Fractional Hp, With Control Panel 240V 50Hz 1) Shaded Pole Motor Make - 1. Crompton Greaves 2. Hindustan Motors 3. Siemens Motors / Rexnord 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , D.C. Compound Generator With Control Panel Including Fitted Rheostat, Voltmeter, Ammeter & Breaker, 2.5 Kw, 220 V & 3 Phase Squirrel Cage Induction Motor 5 Hp, 440 V With Control Panel & Star Delta Starter. Make - Dc Compound Generator Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar / Powerol 3- Phase 1) Induction Motor Make - 1. Crompton 2. Umiya Trading Company 3. Envirotech Engineers 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Used D.C. Generator Series, Shunt & Compound Type For Overhauling Practice. Make - 1. Crompton, 2. Bharat Ele. Motor 3. Kirloskar , Smart Meter 1- Phase - Smart Energy Meter 3 - Phase - Smart Energy Meter Make - 1.Genus Power Infrastructures Ltd 2.Hpl Electric & Power 3.Elmax India / L&T Electric , Ev Charger 3 - Phase Input Make - 1. Tata Power 2. Mahindra Electric 3. Okaya / Delta Electronic / Servotech Power System , Ev Charger (Home) 1 - Phase Input Make - 1. Tata Power 2. Mahindra Electric 3. Okaya / Delta Electronics , Work Shop Main Control Panel With Voltmeter Indicator Ammeter Indicator 1. Maintenance 125 A 440V 2. Output Main Switch - 16A - 08 , 32A - 08 63A - 02 Make - 1. Schneider Elect 2. Siemens 3.Abb 4. L& T , D C Control Panel Income - 440V Ac Output -12V ,24,110V, 240V, 440V, Dc With Indicator Voltammeter Ampire Meter Make - 1. Schneider Elect 2. Siemens 3.Abb 4. L& T , Welding Transformer With All Accessories ( 400A, Ocv 60-100 V, 60% Duty Cycle) Make - Miller / Ador / Esab / I Bell , Welding Transformer (Or) Inverter Based Welding Machine With All Accessories (300A , Ocv 60 - 100 V, 60% Duty Cycle) Miller / Ador / Esab / I Bell , D.C Annual Rate Contract Welding Rectifiers Set With All Accessories (400 A. Ocv 60 - 100 V, 60% Duty Cycle ) Make - Miller / Ador / Esab / Vigor , Gmaw Welding Machine 400A Capacity With Air Cooled Torch, Regulator, Gas Preheater, Gas Hose And Standard Accessories Miller / Ador /Esab / Kemppi , Ac/Dc Gtaw Welding Machine With Water Cooled Torch 300 A, Argon Regulator, Gas Hose, Water Circulating System And Standard Accessories. Miller /Ador / Esab / I Bell / Lincoln , Air Plasma Cutting Equipment With All Accessories, Capacity To Cut 12 Mm Clear Cut Make -Miller / Esab / Hypertherm / Rali Wolf / Technocard Plasma , Air Compressor Suitable For Above Air Plasma Cutting 15 Kw System Two Stage Compressor. 225 Ltr. Auto Cut Tank Cap. 80 -100 Psi Make -Elgi /Allas Capco / Ingersoll Rand / Premier , Auto Darkening Welding Helmet Make -L&T / Bell / Esab / Miller , Spot Welding Machine To 15 Kva With All Accessories Make - Ador / Esab/Artech / Micro Weld , Portable Gas Cutting Machine Capable Of Cutting Straight & Circular With All Accessories Make - Esab/ Pug Nm / Koike India /Ador / Pentagon , Pedestal Grinder Fitted With Coarse & Medium Grain Size Grinding & Wheel Dia-300Mm. Make -Elmaco / Bosch / Vijay Foundry Equipment , Bench Grinder Fitted With Grain Size Silicon Carbide Green Grinding Wheel Dia 150Mm Make - Elmaco / Bosch / Dewalt / Stanley Corded , Power Saw Machine 18 Hp-300 Blade Size - 450 Mm Make -Bosch / Dewalt / Hitachi / Kmi / Atlas Mochal , Portable Drilling Machine Capacity 6Mm. Make - Bosch / Dewal/ Hitachi , Oven Electrode Drying 0To 350C 10Kg Capacity Make - Ador /Arcon /Senso Heat , Die Penetrating Testing Kit. (Machine) Make - Esab / Dubi-Chek / Aerol / Magnaflux , Magnetic Particle Testing Kit. Make -Esab / Canmay /Mag Flux / Magnaflux / Magkraft , Wedding Simulators For Smaw,Gtaw,Gman (Optional) Make - Krb Electronic Soln Rewabsi / Simbott , Water Cooled Induction Welding/ Brazing Machine 200-250 Amp., Induction Coil Length 3 Inch And 2.5 Inch Make - Esab /Micro Tech Induction /Foster Induction /Vel I Braze Snapet / Welding World , Plastic Welding Machine With Hot Air Gun Temp. Display, Variable Temp., Pe, Pp& Pvc Sheet Or Pipe Welding Control With Stand. Accessories. Make - Esab / Leister / New Vimco Ltd /Ajanta Ultra Plast / I Bell / Vormik Vr/Branson Ultrascnies , Ag4 Grinder 100 Mm Dia Make - Dewalt / Bosch /Jk Supper / Metabo , Portable Abrasive Cut Off Machine 107 Mm Dia Make - Dewalt / Bosch / Ingco Hikoki /Mangalam / Century / Emboro , Hand Shearing Machine Cp Cut 6 Mm Sheet & Flat Make - Shakti / Vmt/ M.S. Machine Tools/Tl Pathak Group , Laser Cutting Machine Portable 50 Mm Laser Make - Esab / Toumf / Amada / Parag Weld Algo Laser/ Auto Mstack/Crealrty , Lathe S.S. & S.C. (All Geared Head Stock) With Minimum Specification As: 150Mm Centre Height To Admit 750Mm Between Centres, Machine To Be Motorized And Supplied With Coolant Installation, 4-Jaw Independent Chuck 150Mm., 3-Jaw Self-Cantering Chuck 150Mm. Fixed Steady, Travelling Study, Face Plate, Driving Plate, 4 Way Tool Post, Quick Change Gear Box For Metric Or British Threads, Live And Dead Centre With Taper Turning Attachment Motor Capacity 5.5 Kw. Mt 2 Revolving Centre Qty.2 No. Make - Kirloskar /Hmt/ S Micrometric , Lathe Tool Room S.S. & S.C. . . . (All Geared Head Stock) With Minimum Specification As : 150Mm Center Height, 1000Mm Between Centers, Machine To Be Motorized And Supplied With Coolant Installation, 4-Jaw Independent Chuck 250Mm.,3-Jaw Self-Cantering Chuck 150Mm. Fixed Steady, Traveling Steady, Face Plate, Driving Plate 1-Way Tool Post, Draw In Type Collets Set Up To 25 Mm, 0.5 Mm Relieving Attachment Motor Capacity 5.5 Kw. Mt 2 Revolving Centre Qty.2 No. Make - Kirloskar / Hmt / S Micrometric , Grinding Machine Pedestal Type D.E.200Mm. Dia. Wheel With Wheel Guard And Vision, Motor Capacity - 0.75 Kw. Make - Elmaco / Bosch / Ingco , Cnc Lathe/Cnc Turn Centre Make - Bfw / Moriseiki / Makino , 1) Machine Capacity A. Swing Over Bed - 350 Mm Or Higher B. Turning Diameter - 135 Mm Or Higher C. Distance Between Centers - 250 Mm Or Higher D. Maximum Turning Length - 200 Mm Or Higher E. Slant Angle (Bed Or Saddle) -30 Degrees To Horizontal Or Higher F. Cast Iron Grade For Bed And Saddle - Grade 25 Or Equivalent G. Machine Weight Net - 1500 Kg Or Higher , 2) Spindle A. Spindle Nose -A2-4 / A2-5 B. Bore Through Spindle - 35Mm Or Higher C. Maximum Spindle Speed - 4000 Rpm Or Higher D. Spindle Power, Continuous - 3.7 Kw Or Higher E. Minimum Spindle Speed @ Full Power - 1200 Rpm, Or Lower F. Type Of Drive - Ac Servo Spindle Motor (Digital) G. Chuck Size -135 Mm Or Higher. Chuck Type H.3-Jaw Hydraulic, Hydraulic Power Operated I. Spindle Bearing Class - P4 Class J. Front Bearing Dia. (Id) - 60 Mm Or Higher , 3) Axes A. X - Axis Travel - 100 Mm Or Higher B. Z - Axis Travel -200 Mm Or Higher C. Programmable Feed Rate- X & Z -10 - 10000 Mm/Min D. Minimum Programmable Command -X & Z - 0.001 Mm E. Rapid Traverse - X & Z - 20 M/Min Or Higher F. Type Of Drive - X & Z - Ac Servo Motor G. Motor Torque - Z Axis - 3Nm Or Higher H. Motor Torque - X Axis - 3Nm Or Higher With Brake I. Ball Screw - Z & X Axes (Diameter X Pitch) - 25 X 10 Mm Or Higher J. Ball Screw Finish - Z & X Axes - Hardened And Ground K. Ball Screw Class- Z & X Axes - Pre-Loaded With C3 Or Better L. Guide Way Type - Z & X Axes - Antifriction Linear Motion Guide Way M. Guide Way Size - Z & X Axes - 25Mm Or Higher N. Guide Way Precision - Z & X Axes - P Class , 4) Turret A. Bi-Directional Tool Turret - Electromechanical/Servo/Hydraulic B. No. Of Tools - 8 Nos. Or Higher C. Tool Shank Size - 20 X 20 Mm Or Higher D. Maximum Boring Bar Diameter - 25 Mm Or Higher , 5) Tail Stock A. Quill Diameter - 65 Mm Or Higher B. Quill Stroke - 70 Mm Or Higher C. Quill Taper- Mt-4 Or Higher D. Quill Actuation - Hydraulic E. Tail Stock Base Travel Manual - 150 Mm Or Higher F. Thrust (Adjustable) - 300 Kg For Higher , 6) Coolant/Lubrication/Hydraulic A. Coolant Tank Capacity - 100 Liters Or Higher B. Coolant Pump Motor - 0.37 Kw C. Coolant Pump Out Put - 20 Lpm Or Higher D. Lubrication Type - Automatic Centralized Lubrication E. Lubrication Tank Capacity 3 Liter Or Higher F. Hydraulic Pump Discharge - 8 Lpm Or Higher G. Hydraulic Tank Capacity - 30 Liters Or Higher H. Hydraulic System Pressure Maximum -30 Bar Or Higher , 7) Accuracy As Per Iso 230-2 A. Positioning Accuracy X & Z Axes - 0.012Mm B. Repeatability X & Z Axes - ± 0.007Mm C. Geometrical Alignment - Iso 13041-Part 1 D. Accuracy Of Finish Test Piece - Iso 13041-Part 6 , 8) Cnc System A. Control System - Fanuc / Siemens B. System Resolution - 0.001 Mm C. Motors & Drives - Compatible With Cnc Controllers Mentioned Above D. Tool Number Display - On Machine Operator Panel E. Machine Control Panel - Feed Rate, Spindle Speed Override Knob F. Mpg (Manual Pulse Generator) - On Machine Operator Panel G. Cnc Features - Graphic Simulation, Programming Help, Tool Offsets, Mdi, Absolute/ Incremental Positioning, Pitch Error Compensation , 9) Power Source A. Mains Supply (± 10 %) - 415 V, 3 Ph., 50Hz B. Total Connected Load Requirement - Approx. 15 Kva , 10) Standard Equipment A. Voltage Stabilizer 15 Kva B. Air Conditioning Unit For Electrical Cabinet - 1 No. Backup Cd For Plc Ladder Logic - 1 No. D. Machine Lighting - 1 No. E. Levelling Pads And Jacking Screws - 4 No. F. Operation Manual - 1 No. G. Maintenance Manual - 1 No. H. Installation Kit - 1 No. I. Maintenance Tool Kit - 1 No. J. 6 Rack Trolley (Size 25X22X45) With Lock - 1 No. K. Machine Guarding With Safety Compliance - 1 No. , 11) Makes Of Critical Machine Tool Components A. Linear Motion Guide Ways - Hiwin/Thk/Pmi/Star B. Ball Screws - Hiwin/Thk/Tsubaki/Pmi/Star/Hmt/Nsk C. Spindle Bearings - Rhp/Nsk/Fag/Skf/Nrb D. Turret - Pragati/Baruffaldi/Sauter/Duplomatic E. Hydraulic Chuck & Cylinder - Gmt/ Kitagawa / Airtech /Pragati / Rohm F. Hydraulic Power Pack - Yuken/Fluid/Rexroth G. Panel Ac - Werner Finley/Rittal/Lextecnoid H. Stabilizer - Neel/Servomax /Consul/Farmax/Equivalent I. Lubrication- Cenlube/Dropco/Equivalent J. Coolant Pump - Rajamane/Grundfos K. Cutting Tools And Holders - Sandvik/Taegutec/ Kennametal /Seco/Iscar/Mitsub Ishi , 12) Cutting Tools & Tool Holders 1. External Turning Holder, Insert Type, Mwlnl - Holder 4Qty. (Insert Wnmg 40 Nos.) 2. External Turning Holder, Insert Type, Mvjnl - Holder 4Qty. (Insert Vnmg 20 Nos.) 3. External Turning Holder, Insert Type, Pdjnr - Holder 4Qty. (Insert Dnmg 20 Nos.) 4. Threading Holder - External, Lh - Holder 4Qty. (Insert 0.5 To 2 30 Nos.) 5. Threading Holder - Internal, Lh - Holder 4Qty. (Insert 0.5 To 2 30 Nos.) 6. Grooving Holder External, Lh - Holder 4Qty. (Insert 3Mm 30 Nos.) 7. Grooving Holder Internal, Lh - Holder 4Qty. (Insert 3Mm 30 Nos.) 8. Parting Off Holder For Insert Width 2 Mm, Lh - Holder 4Qty. (Insert 2Mm 30 Nos.) 9. Boring Holder Sclcl For Minimum Bore Dia. 12Mm - Holder 4Qty. (Insert Wcmt 60 Nos.) 10. Boring Holder Sclcl For Minimum Bore Dia. 16 Mm - Holder 4Qty. (Insert Ccmt 60 Nos.) 11. Internal Grooving Holder Lh, For Minimum Bore Dia. 12 Mm - Holder 4Qty. (Insert 2Mm 30 Nos.) 12. Internal Threading Holder Lh, For Minimum Bore Dia. 12 Mm - Holder 4Qty. (Insert W Mm 30 Nos.) 13. Insert Drill 12.7 Mm - Holder 4Qty. (Insert Suitable 30 Sets.) 14. Reducing Sleeves For Internal Holders - Dia 12 And 16 Mm - 2 Sets 15. Centre Drill Hss A 2.5 X 6.3 - 6 Qty. 16. Twist Drill Hss Straight Shank, Dia 6,8,10,12 Mm - 6 Sets 17. Collets Suitable For The Above Drills - 2 Sets 18. Collet Holder - 4 Nos. 19. Boring Bar Holder - 3 Nos C.N.C Lathe Machine With Accessories. 1. D- List Of Additional Machines, Tools And Equipment For Cnc Turn Center : D) Digimatic Electronic Vernier Caliper 200 Mm. - 2 Nos. E) Digimatic Electronic Outside Micro Meter (0 To 25 Mm & 25 To 50 Mm) Lc 0.001 Mm. - 1 Nos Each. , Desktop Computers Compatible To Run Simulation Software With Lan Facility. Dell / Lenovo / Hp Specification - Cpu - 64 Bit I7 Or Latest Processor Speed - 3Ghz Or Higher Ram 12 Gb Ddr - Iii Or Higher, Wi-Fi Enabled. Network Card - Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor (Min. 21 Inch.) Licensed Operating System And Antivirus Compatible With Trade Related Software. 01 Tb Hard Disk Nvidia Graphic Card , Ss And Sc Centre Lathe (All Geared) With Minimum Specification As: Centre Height 150 Mm And Centre Distance 750Mm Along With 4 Jaw Chuck, Self-Centering Chuck, Auto Feed System, Safety Guard, Motorized Coolant System And Lighting Arrangement, Set Of Lathe Tools, Lathe Carriers Make - Kirloskar /Hmt/ S Micrometric , Pillar Drill Machine (All Geared) 0-25Mm Drill Holding Capacity With Drill Chuck & Keys. Make - Ifco/ Skp / Energi , Cylindrical External Grinding Machine Fully Motorized With Dressing Arrangement And Supplied With Face Plates And Driving Dogs, 3 Jaw Self-Centering Chuck,4 Jaw Independent Chuck, Tail Stock Assorted Center Pump With Tank And Pipe Fittings Spanners And Grease Gun (Each Machine To Be Supplied With Assorted Grinding Machine For General Purpose Work With Internal Grinding Attachment) With Minimum Specification As: To Accommodate 750Mm Job With Center Height 150Mm. Wheel Diameter X Width=300X25Mm Make - Hmt-K 130 U / S-Micrometic / Hi Life , Radial Drilling Machine 32Mm Diameter With Std. Accessories. Drill Chuck & Plain Machine Vice 250 Mm Make - Hmt / Bfw / Batliboi , Lathe Tool Room S.S. & S.C. . . . (All Geared Head Stock) With Minimum Specification As : 150Mm Center Height, 1000Mm Long With 3-Jaw, 4-Jaw Chuck Auto Feed System, Taper Turning Attachment, Coolant Pump, Safety Guard, And Machine Light Arrangement. Make - Kirloskar / Hmt / S Micrometric , Rockwell Hardness Testing Machine Digital Type With Standard Accessories / Digital Type Make - Mitutoyo/ Sagar/ Sinowon / Saroj / Sai Dro , Profile Projector (5 Micron) Re Solution 0.001Mm Projection Scream - Effective Diameter 300 Mm, Rotation Angle: +/- 360 Degree Angle Reading - 0.01 Degree Or 1 (Commutative) Projection Lens - 10 X Lens Group (Standard Arrangement) 20X50X100 X Is Set As On Option. Measuring Range - 200X200 Mm Quickly Move X, Y Axes, Power : 220 Vac Make - Mitutoyo / Nicon / Metzer , Co-Ordinate Measuring Machine (5 Micron) Measuring Range 500X700X500Mm Make - Nicon / Mitutoyo / Devine Technology , Fly Press (Any Model Minimum 12 Tons Capacity) Make - Taj Enterprises / Bharat Machinery And Spares / Orient Machine Tool , Power Press M/C (Hydraulic) Minimum 02 Tons Capacity Standard And Required Optional Accessories Make - Foreman / Amino / Omkar Enterprises , Auto Cad & Cam Latest Version - For Training Purpose Make - Autodesk , Solid Works / Any Latest - Latest Version - For Training Purpose Make - Dassasult System Solid Work Corporation , Smart Touch Screen Panel For Smart Class Room (65) Usb Connector, Led Interactive Pen, Mounting, Users Manual Electronics File Make - Samsung / Smart Guru / Vincon System , Multimedia Based Simulator For Cnc Technology & Interactive Cnc Part Programming Software For Turning & Milling With Virtual Machine. Operation & Simulation Using Popular Operation. Control System Such As Fanuc, Siemens, Etc. (Web-Based Or Licensed Based.) - For Training Purpose Make - Cad Mech / Indiasoft / Fanuc / Krb Electronic Solution , Cnc Vertical Machining Centre With Std. Accessories Make - Bfw / Moriseiki / Makino Specification , 1) Machine Capacity A)Table Size - 500X250 Or Higher Mm B) Max. Load On Table 150 Or Higher C)T Slot Dimension (N X W X P) Mm 3X14X100 Or Higher D)Table Height From Floor 800 ~ 900 Mm E) Cast Iron Grade For Bed And Saddle Grade 25 Or Equivalent F)Machine Net Weight 1500 Or Higher Kg , 2) Spindle A) Spindle Nose Bt30 B) Minimum Distance (Spindle Nose To Table)100 - 150 Mm D) Maximum Spindle Speed 6000 Or Higher Rpm E) Spindle Power, Continuous 3.7 Or Higher Kw F) Type Of Drive Ac Servo Spindle Motor (Digital) G) Spindle Bearing Class P4 H) Front Bearing Dia. (Id) 50 Or Higher Mm , 3) Axes A) X - Axis Travel 300 Or Higher Mm B) Y - Axis Travel 250 Or Higher Mm C) Z - Axis Travel 250 Or Higher Mm D) Rapid Traverse - X/Y/Z 20/20/20 Or Higher M/Min E) Minimum Programmable Command X/Y/ Z - 0.001 Mm F) Programmable Feed Range - X, Y & Z Axes 10 - 10000 Mm/Min G) Type Of Drive Ac Servo Motor H) Motor Torque - X & Y Axes 3 Or Higher Nm I) Motor Torque - Z Axis 6 Or Higher With Brake Nm J) Ball Screw - X,Y& Z Axes (Diameter X Pitch) 25 X 10 Or Higher Mm K) Ball Screw Finish - X, Y & Z Axes Ground And Hardened L) Ball Screw Class - X, Y & Z Axes Pre-Loaded With C3 Or Better M) Guide Ways - X, Y & Z Axes Antifriction Linear Motion Guide Way N) Guide Ways Size - X, Y & Z Axes 25 Or Higher Mm O) Guide Way Precision - X, Y, & Z Axes P Class , 4) Automatic Tool Changer A) Number Of Tool Pockets 8 Or Higher Nos B) Max Tool Diameter 80 Or Higher Mm C) Tool Selection Bi-Directional D) Tool Shank Type Bt30 E) Tool Weight Max 2.5 For Bt30 F) Tool Length Max 100 ~150 For Bt30 G) Tool Change Time (Chip To Chip) 5 Or Lower Sec H) Tool Clamp & Unclamp Disc Spring & Hydro-Pneumatic , 5) Accuracy As Per Iso 230-2 A) Positioning Accuracy For X,Y & Z Axes 0.012 Mm B) Repeatability For X,Y & Z Axes ±0.007 Mm C) Geometrical Alignment Iso 10791-Part 1 D) Accuracy Of Finish Test Piece Iso 10791-Part 7 , 6) Cnc System A) Control System - Fanuc B) Motors & Drives Compatible With Cnc Controllers As Mentioned Above C) System Resolution 0.001 Mm D) Tool Number Display On Machine Operator Panel E) Machine Control Panel Feed Rate, Spindle Speed Override Knob F) Mpg (Manual Pulse Generator) On Machine Operator Panel G) Cnc Features Graphic Simulation, Programming Help, Tool Offsets Mdi, Absolute/Incremental Positioning, Pitch Error Compensation , 7) Coolant/Lubrication A) Coolant Tank Capacity 100 Or Higher Litres B) Coolant Pump Motor 0.37 Kw C) Coolant Pump Output 20 Or Higher L Pm D) Lubrication Type Automatic Centralized Lubrication E) Lubrication Tank Capacity 3 Or Higher Liters , 8) Air Compressor For Tool Unclamp A) Compressor Type Screw Type With Dryer, Filter & Air Receiver B) Tank Capacity 200 Or Higher Liters C) Air Flow 10 Or Higher Cfm D) Pressure 7 Max. Bar , 9) Power Source A) Mains Supply (± 10 %) 415 V, 3 Ph., 50Hz B) Total Connected Load Requirement Approx. 15 Kva , 10) Standard Equipment A) Voltage Stabilizer 15 Kva B) Air Conditioning Unit For Electrical Cabinet As Required C) Backup Cd For Plc Ladder Logic 1 No. D) Machine Lightning 1 No. E) Levelling Pads And Jacking Screws 4 Nos. F) Operation Manual 1 No. G) Maintenance Manual 1 No. H) Installation Kit 1 No. I) Maintenance Tool Kit 1 No. J) 6 Rack Tool Trolley (Size 25X22X45) With Lock 1 No. H) Machine Guarding With Safety Compliance 1 No. , 11) Makes Of Critical Components A) Lm Guide Ways - Hiwin/Thk/Pmi/Star B) Ball Screws - Hiwin/Thk/Tsubaki/Pmi/Star/Hmt/Nsk C) Spindle Bearings - Rhp/Nsk/Fag/Skf/Nrb D) Atc - Pragati/Gifu E) Panel Ac - Werner Finley/Rittal/Lextecnoid F) Stabilizer - Neel/Se Rvomax/Consul/Farmax G) Lubrication - Cenlube/Dropco H) Coolant Pump - Rajamane/Gru Ndfos I) Cutting Tools And Holders - Sandvik/Taegutec/Ken Nametal/Seco/Mitsubishi J) Air Compressor (Capacity: 6 Kg/Cm2 - 300 Godrej/Elgi/Kaeser/Atlascopco L Pm Min.) , 12) Cutting Tools & Tool Holders (For Bt30 As Per Machine Supplied) A. Face Mill 45 Degree 63 Mm. Insert Type - 4 No. Suitable Inserts - 15 No. B. Face Mill Square Shoulder 50 Mm. Insert Type - 4No. Suitable Inserts - 15 No. C. Twist Drill Hss Straight Shank 6, 6.7, 8.5, 9.7 - 4 No. D. Spot Drill Carbide, Dia. 8 Mm X 90° - 4 No. Suitable Inserts - 60 No. E. Drill Insert Type - 16 Mm - 4 No. Suitable Inserts - 30 No. F. Solid Carbide Twist Drill Straight Shank - 8 Mm - 4 No. G. Solid Carbide End Mill Straight Shank - 10, 12 Mm Dia. - 4 No. H. End Mill Insert Type Straight Shank - 16 Mm Dia. - 4 No. Suitable Inserts - 30 No. I. Machine Taps Hss - M8, M10 - 4 No. J. Solid Carbide Reamer Straight Shank - 10 Mm - 4 No. K. Finish Boring Bar Dia. 20 To 25 Mm- 3 No. Suitable Inserts - 30 No L. Holder For Face Mills (Adapter) - 4 No. Suitable Incert - 60 Nos. M. Collets For Above Drills, Reamers, End Mills - 02 Sets N. Collet Holder Suitable For Collets - 4 No. O. Side Lock Holder For 16 Mm Insert Drill - 2 No. P. Machine Vice 0-150 Mm Range - Mechanical Type - 1 No. Q. C Spanner For Tightening Tools In Holder - 2 No. R. Magnetic Dial Stand - 2 No. S. Mallet - 02 No. T. Tap Wrench - 2 No. U. Hands Tools Set ( Spanners, Allen Keys, Etc.,) - 1 Box V. T Nuts, Strap Clamps, Clamping Nuts And Studs - 2 Set , Three / Four Door Refrigerator (Inverter Type) Specification - 300 Liter With Hc-600 A Gas. (1 Each) Make - Godrej / Whirlpool / Lg , Core Drill Machine Specification - Up To 2 To 2.5 Hammer Chiseling Bit 1500 Watt Make - Crompton / Power Hours / Bosch , Duct Able Split A/C Reciprocating Compressor Specification - Cap 1.5 Ton With R-22 Evapora(4 Copper) Make - Blue Star / Voltas / Daikin , Recovery Unit With Cylinders Specification - Cfc-Hfc,Hcfc, - 1 Each Cylinders Make - Trust Hal / Robin Air Rg-3 / Rishabh Enterprises , Decibel Meter 03 To 100 Db Make - Cadrim / Bosch / Generc , Descaling Pump Set With Stainless Steel Impeller And Accessories (1/2 Hp) Make - Bosch / Crompton / Robin Air , Fan Coil Unit With Water Valves Specification - 2 Way & 3 Way Valves (02 Ton) Make - Nutech Zeco / Blue Star / Voltas , Circulating Water Pump 0.5 Hp With Stainless Steel, Tank Capacity Inlet/Outlet Provision Make - Sharp / Lubi / Crompton , Water Cooler Storage Type Hfc-134A Specification - 200 Litter Reciprocating Compressor. Make - Blue Star /Voltas / Usha , Package A/C Air Cooled Type With Open Type Reciprocating Compressor Fins Type Condenser (05 Ton) Make - Blue Star / Voltas / Daikin , Bus A/C Tutorial Model Make - Estern Air / Tata Motors / Cool Ways. Ltd , Automatic Ice Coober Machine Specification - 5 Kg/Hr., Ice Cube - Material Stainless Steel Make - Godrej / Voltas / Blue Star , Walk In Cooler Puf Insulated Cold Room Specification - 01 Ton, 6X5X8 Foot, Cold Room Temp - 0 To 5° C Degree. Air Cooled Evaporator & Condenser Copper Tubing. Make - Unicool / Blue Star / Voltas , Shell Tube Type Dx Chiller Specification - 5 Ton Material - Copper Tubing Only Make - Voltas / Blue Star / Carrier
Contract Date: Ref. Documents Contract Value : Ref. Document
Trust & NGO No of Bidders 3
Maharashtra View Result →
10.
Educational and Research Institute #10734365 AOC
Notice Inviting Etender For Procurement Of Equipment, Instruments, Machineries, Tools Charts Etc. Related To Laboratories And Workshop Of Engineering Institute For Junior Executives, Dalalpukur, Howrah-711104-1 Dead Weight Pressure Gauge Tester • Bourdon Tube Pressure Gauge As Manometer • Manometer With Transparent Scale • Manufactured From Corrosion Resistant Materials • Components Arranged On Base Plate. • Set Of Weights • Medium For Transmitting Pressure: Hydraulic • Capacity Of 25Kg / Cm2 • The System Is Nickel Chrome • The Weights Are Zink Iron ) 2 Cut Section Model Of Hermetically Sealed Compressor 3 Universal Bevel Protractor ( Accuracy: 0.01 Mm Material: Stainless Steel Diameter: 70 Mm Size: 300 Mm Type: Analog Graduation 5 Min Straightness .00016+ ( .00005Xl / 2 ) ) 4 Cut Section Model Of Lamont Boiler 5 Slip Gauge Set; Special Set ( M87 ) , Grade I, High Grade Steel, 9 Mm Wide & 30-35 Mm Long Cross Section. 6 Utm Machine ( Material:Ms Voltage:220 V Phase: Single Phase Capacity: 10 To 100 Ton Cross Travel: Up To 1000 Mm Weight: 1500 Kg ) 7 Mollier Chart Flex ( 40 × 30 ) 8 Teak Wood; Wood For Pattern Shop Size: 2×1×6 9 Thermal Conductivity Of Metal Rod; • Frame: Made Of M.S. Square Tubes & Sheets, Welded & Powder Coated • Optional Accessories: Rotameter For Water Flow Measurement • Electric Heater : Clamp Heater, Capacity 200 W, Supply 230 V Ac • Insulation Jacket: Made Of Mild Steel, Mild Steel Rod Is Insulated By Asbestos Powder • Diameter Of Metal Rod 25 Mm, Length Of Rod 300 Mm 10 Cut Section Model Of Screw Type Rotary Air Compressor 11.01 Chart Of Velox Boiler With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.02 Chart Of Mollier Diagram With Labelling ( Size: 23’’ X 36’’, Material: Pvc, With Roller ) 11.03 Chart Of T-T-T Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.04 Chart Of Utm Machine & Sample With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.05 Chart Of Torsion Testing Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.06 Chart Of Iron-Carbon Equilibrium Diagram With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.07 Chart Of Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.08 Chart Of Vernier Height Gauge With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.09 Chart Of Thread Measurement With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.10 Chart Of Gear Tooth Vernier Caliper With Labeling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.11 Chart Of Hermetically Sealed Compressor With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.12 Chart Of Domestic Refrigerator With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.13 Chart Of Full Pressure Engine Lubricating System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.14 Chart Of Constant Mesh Gear Box With Labeling ( Size:30× 40, Material: Pvc, With Roller ) 11.15 Chart Of Synchromesh Gear Box With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.16 Chart Of Components Of A Chasis With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.17 Chart Of Knuckel Joint With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.18 Chart Of Intersection Of A Prism And Cone ( Size:30× 40, Material: Pvc, With Roller ) 11.19 Chart Of Projection Of A Straight Line In Different Quadrants ( Size:30× 40, Material: Pvc, With Roller ) 11.20 Chart Of Plummer Block - Details And Arrangement ( Size:30× 40, Material: Pvc, With Roller ) 11.21 Chart Of Centrifugal Pump With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.22 Chart Of Balanced Type Vane Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.23 Chart Of Bent Axis Piston Pump With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.24 Chart Of Lathe Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.25 Chart Of Single Point Cutting Tool Geometry With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.26 Chart Of Screw Jack Assembly With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.27 Chart Of Cotter Joint Assembly And Design With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.28 Chart Of Vertical Drilling Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.29 Chart Of Shaper Machine With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.30 Chart Of Safety On A Lathe Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.31 Chart Of Safety On A Milling Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.32 Chart Of Safety On A Shaper Machine ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.33 Chart Of Safety In Carpentry Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.34 Chart Of Safety In Fitting Shop ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.35 Chart Of General Precaution In Workshop ( Size:30× 40, Material: Pvc, With Roller ) 11.36 Chart Of Cnc Turning With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.37 Chart Of Elements Of Jigs ( Drill Bushes ) With Labelling ( Size:23’’ X 36’’, Material: Pvc, With Roller ) 11.38 Chart Of Tig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.39 Chart Of Mig Welding With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 11.40 Chart Of Engine Cooling System With Labelling ( Size:30× 40, Material: Pvc, With Roller ) 12 Digital Lab Trainer ( Bread Board Model ) ( Built-In Dc Regulated Power Supply; At Least 8 Logic Input Switches; At Least8 Output Led; Pulse Generator For Clock Frequency ; Patch Chords ) 13 Arduino Uno Board ( Atmega328 ) 14 Experimental Kit To Study Pam, Pwm And Ppm Modulation And Demodulation ( Pulse Generator With Variable Frequency And Amplitude, Pam Modulator And Demodulator, Pwm Modulator And Demodulator, Ppm Modulator And Demodulator ) 15 Ujt Trainer Kit With P.S. & Patch Cord 16 Led Colour Tv Demonstration Kit ( Display Type: Led, Hd: Screen Size: 24: Connectivity: Usb, Hdmi, Av: Test Points To Be Present Minimum 10 Nos.: Switched Faults To Be Provided: Product Tutorial Should Be Present ) 17 Microwave Oven Demonstration Trainer Kit ( Type: Solo: Capacity: 17 Ltr.: Control Type:Mechanical: All Circuits & Panels To Be Mounted On-Board: Test Points To Be Provided To Analyze Signals: Instruction Manual To Be Provided ) 18 Washing Machine Demonstration Trainer Kit ( Application: Lab Experiment: Semi-Automatic: Tank Capacity: 6.5 Kg: Block Diagram & Circuit Diagram To Be Mounted On The Lid: Test Points To Be Provided ) 19 Mobile Communication Trainer Kit To Study Various Signalling And Fault Insertion Techniques ( Gsm Handset Trainer Kit.  Operate Both On Windows And Linux Platform  Usb Interface For Communication  Best Suitable For Iot Gateway Application  External Connector To Interface With Any Microcontroller  Easy Understanding Of At Commands  Real Time Operation  Built In Network Status Led  Audio Interface Connector  Simple / Easy Operation  External Antenna  Application Module Relay Interface For Ac Device ( Optional ) ) 20 Trainer Kit For Mobilephone Set To Study Transmitter And Receiver Sections In Mobile Handset And Measure Frequency Band Signal ( Real Time Mobile Operation # Full Understanding Of Mobile Phone Working # Frequency Measurement And Band Verification # Provides Study Of All Sections In Mobile Phone # Tx / Rx Frequency Measurement # 3G / 4G Technology And Gmsk Signals # Gsm Data Rate # Detail Study Of User Interface Control Signals # Detail Study Of Sim Operation # Battery Identification And Charging Study  Switched Faults 21 Consumable ( 9V Battery, Cro Probe, Digital Ics ) 22 Cro ( 20 Mhz , Dual Trace, Dual Channel ) 23 Trainer Kit For Mobile Phone ( Features : The Experimental Kit Will Be Capable I ) To Study General Block Diagram Of A Mobile Phone. Ii ) To Study Mobile Transmission Section. Iii ) To Study Mobile Reception Section. Iv ) To Study Different Nos. Of Faults Provided With The Trainer. V ) To Study & Observe Voltages / Waveforms Of Each Test Points. Vi ) To Study Mobile Charging Circuits. Vii ) To Use Mobile Phone As Modem For Using At Commands As Given; A ) Sending Text Messages, Read / Delete Massages Etc. B ) Calling To A No, Reject / Accept The Incoming Calls Etc. C ) Gprs Related Commands. Study Of Bluetooth Technology & Connection With Other Bt Devices. Bluetooth Profiles : Bip, Bpp, Dunp, Ftp, Hid, Opp , Sap, A2dp, Pbap, Spp Etc. To Study General Idea Of Sim Card. ( Local Sim Card Must Be Inserted By The User At The Time Of Experiment ) . ) 24 Salt Bath Furnace For Heat Treatment ( • Resistance Heating ( Element ) • Operating Temp.: Up To 1200°C • Digital Temp. Controller ( Pid ) • Chamber Size : 450Mm X 300 Mm X 300 Mm • Furnace Uniformity + / - 2°C • Temp Recorder With 2 Channel Placed At Opposite Sides • Salt For Use With Two Times Top Up • Spare Heating Element 2Pc ) 25 In-Situ Metallography Kit ( • Items: Portable Grinder / Polisher, Grinding Discs, Lapping Cloths, Diamond Pastes, Aerosol Spray, Replication Film, Paste, Reflector And Gumming Tape For Excellent Contrast Or Transparent Replica - Film Thickness - 125 Microns, 30 Microns, Replica Liquid, Glass Slides ) 26 Automatic Electrolytic Polishing Machine ( • Function: Fully Automatic Electrolytic Polishing And Etching With Automatic Scanning Function • Preparation Time: Within 30 Sec • Electrolyte For Low / High Alloyed Steels & Aluminium • Pump And Magnetic Stirrer • Integrated Cooling System ) 27 Micro-Hardness Tester ( • Test Load : 10, 25, 50, 100, 200, 300, 500, 1000 Gm • Scale: Knoop & Vickers • Dwell Time: 5-90 Seconds Settable • Objectives : 10X, 20X, 40X, 60X • Loading And Unloading : Motorized • Measurement – Automatic And Or With Manual Micrometer Eyepiece. • Traverse: Automatic And Or Manual With Micrometer. • Focusing - Motorized Focusing With Manual Over-Ride • Computerized Imaging Attachment, Dedicated Software To Measure Hardness On Computer With Report Generation Facility • Accessories: Sheet Holder, Wire Holder, Hardness Test Block, Bulb, Indenter. ) 28 Cracked Aluminum Test Block ( For Penetrant Sensitivity Checking In Dpt ) ( Aluminum Test Piece That Measures 3 X 2 X 3 / 8 With A 1 / 8 Wide With A Milled Notch That Separates The Blocks Two Sides To Facilitate Side-By-Side Penetrant Comparison. The Test Block Is Used To Check The Strength Of “In-Use” Penetrants. This Is Done By Processing One Half Of The Block With “Used” Penetrant, And The Other Half With Fresh Penetrant. Can Be Used To Compare Sensitivity Of Different Penetrants Or Sensitivity Of New And Old Penetrants. Complies With Astm E165 And Asme Boiler And Pressure Vessel Code Section V & Iii, And Mil-I-23135-C. ) 29 Pie Gauge / Magnetic Flux Indicator ( To Be Made From Eight Ferrous Segments, Braised Into A Single Piece, Providing A Star Pattern Of Nonferrous Discontinuities. Eight Linear Discontinuities To Provide Indications In All Directions Non-Ferrous Handle With Pivot. Specification Compliance • Mil-Std-271 • Astm E709 ) 30 20Mhz Analog Cro ( Dual Trace ) , Bandwidth:- Dc ~ 20Mhz ( -3Db ) Y Deflection:- 5Mv / Div ~ 10V / Div. Rise Time:- <18Ns,Mag _70Ns :17.5Ns. Max Input:- 400V ( Dc+Acp-P ) 31 50Mhz Digital Storage Oscilloscope, Bandwidth 50Mhzreal-Time Sampling Rate 500 Msa / S, Equivalent Sampling Rate 50Gsa / S.Memory Depth: 32Kptstrigger Types: Edge, Pulse Width, Video, Slope, Alternativeunique Digital Filter Function And Waveform Recorder Function, Max Input:- 400V ( Dc+Acp-P ) 32 3D Model Showing Different Parts Of A Coal Fired Thermal Power Station 33 3D Model Showing Different Parts Of A Gas Fired Thermal Power Station 34 3D Model Showing Different Parts Of A Diesel Power Station 35 3D Model Showing Different Parts Of A Nuclear Power Station 36 3D Model Showing Different Parts Of A Hydro-Electric Power Station 37 3D Model Of Boiler Showing Its Different Parts Used In Coal Fired Thermal Power Station 38 3D Model Of Boiler Showing Its Different Parts Used In Nuclear Power Station 39 3D Model Of Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant 40.1 Colour Flex Chart Describing Different Parts Of A Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.2 Colour Flex Chart Describing Different Parts Of A Gas Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.3 Colour Flex Chart Describing Different Parts Of A Diesel Power Station Size:30× 40, Material: Pvc, With Roller 40.4 Colour Flex Chart Describing Different Parts Of A Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.5 Colour Flex Chart Describing Different Parts Of A Hydro-Electric Power Station Size:30× 40, Material: Pvc, With Roller 40.6 Colour Flex Chart Describing Different Parts Of Boiler, Used In Coal Fired Thermal Power Station Size:30× 40, Material: Pvc, With Roller 40.7 Colour Flex Chart Describing Different Parts Of Boiler, Used In Nuclear Power Station Size:30× 40, Material: Pvc, With Roller 40.8 Colour Flex Chart Describing Water Turbine Showing Its Different Parts, Used For Hydro-Electric Power Plant Size:30× 40, Material: Pvc, With Roller 41 3-Phase Induction Motor Speed Control Using Pwm Inverter For Interpreting Speed-Torque Characteristics Using Vvvf Drive 42 Ups Trainer Kit ( 1Kva ) Output Voltage : 230 V Ac Nominal, Input Voltage : +12V Dc Battery. Capacity : 1Kva, Output Frequency : 50 Hz Accuracy : + 5%. Switching : Automatic. 43 Smps Trainer Kit Incl. ±5V, ±12V Input Voltage: Ac 100 – 264V 50 / 60Hz Output Voltage: 12V Dc, 0-5A Output Voltage: Adjustment Range: ±20% Protections: Overload / Over Voltage / Short Circuit Auto-Recovery After Protection Universal Ac Input / Full Range 100% Full Load Burn-In Test Cooling By Free Air Convection High Quality And High Performance Led Power Supply With A Metal Body For Hidden Installation For Led Lighting Design With Built-In Emi Filter, Improve Signal Precision. Certifications: Ce & Rohs No Minimum Load. Compact Size Light Weight. High Efficiency, Reliabiltiy & Low Energy Consumption Controller: Satandard 44 Commutation Kit Of Scr ( Class A To F ) Completely Self – Contained Stand – Alone Unit. Demonstrates The Principle And Various Methods Of Forced Commutation Of Scr. 1. Self-Commutation By Resonating Load ( Class “A” Method ) . 2. Self-Commutation By An L C Circuit ( Class “B” Method ) . 3. Complimentary Commutation ( Class “C” Method ) . 4. Auxiliary Commutation ( Class “D” Method ) . 5. External Pulse Commutation ( Class “E” Method ) . * Supply Required 230V, 50Hz Ac. * Built-In Ic Based Dc Regulated Supply And Led Indication For Supply “On”. * Built-In Load Facility In The Form Of Led’S. * Connecting Each Circuit Separately And Verifying Its Principle. * Multicoloured Test Points Are Provided To Observe The Waveform And Voltages. * Set Of Required Number Of Patch Cords. * Housed In An Elegant Cabinet With A Well Spread Intelligently Designed Circuit Layout Engraved On The Front Panel. * Strongly Supported By A Comprehensive Instruction Manual Complete With Theory And Operating Details. 45 Colour Flex Chart Describing Single Line Diagram Of A Given Distribution System ( Lt & Ht ) Size:30× 40, Material: Pvc, With Roller 46 Colour Flex Chart Describing Short Transmission Line ( 220Kv ) Size:30× 40, Material: Pvc, With Roller 47 Colour Flex Chart Describing Medium Transmission Line ( 220Kv ) ( Both T & Π-Model ) Size:30× 40, Material: Pvc, With Roller 48 Power Factor Improvement Kit Using Static Condenser Including Load R-L Load Of At Least 2Kva With Appropriate Capacitor Bank. 49 Setup For Load Test On 1-Ph Induction Motor: Load Test Kit Of 1-Ph Induction Motor ( 1Hp, 230V, 50Hz ) 50 Loading Test Kit Of 3-Phase Alternator: ( 2Kw, 415V, 50Hz ) With 3-Ph R-L Load Box Coupled To A Dc Motor; Capable To Perform As Synchronous Motor Test With Dc Generator Load; Integrated With All Required Measuring Instruments 51 Speed Control Kit Of Stepper Motor Including Reversing Arrangement With 8051 Microcontroller: Stepper Motor Of Appropriate Capacity To Be Served By 8051Μc 52 Speed Control Kit Of Ac Servo Motor: Motor Spec: 3000Rpm, 200W, 0-240V, Control Torque: Standard With All Needed Accessories 53 Speed Control Kit Of Dc Servo Motor: •Voltmeter Vdc 3.5 Digit. 200Mv •Rpm Indicator For Speed Measurement •Voltmeter Vdc 3.5 Digit 20V Power Supply: •Ic Regulation In Controller Circuit Power Supplies •Operated On Mains Power 230V, 50Hz +10% Features: •Position Control Of A 12 Volt, 1 Amp Dc Geared Pm Motor ( 50 / 60 Rpm ) •Calibrated Dials With 1 Degree Resolution For Reference And Output Position •Two 360 Degree Servo-Potentiometers •Built In Step Signal •Built In Waveform Capture / Display Card For Study Dynamic •Electronic Techogenerator For Feedback •Non-Contact Eddy Current Break For Load •Speed Control Of 12V, 4W, Permanent Magnet Dc Motor •Speed Range Up To 3000 Rpm ( Typical 54 Mcb Test Kit For Performing Load Test: Kit Should Be Able To Perform Short-Circuit, Over Load, Thermal Trip Test For Mcb With Rating Upto 30A 55 Dismantled Elcb & Rccb Kit For Demonstration Purpose: Elcb: Single Phase 2 Pole Elcb, Rccb, Isi Marked 32A Mcb With High Voltage, Overload Protection, Current 3 To 30 Ma Rccb: Breaking Capacity 10 Ka, Frequency, 50 Hz, Number Of Poles 2P, Operating Characteristics: Ac Rated Current 40 A, Sensitivity 30 Ma, Standard, Is 12640-1 & Iec 61008-4, Test Button Yes 56 Testing Kit For Percentage Differential Protection Of Transformer Using Transformer Differential Relay ( Electromagnetic / Μp Based / Static ) : Standard For Laboratory Purpose 57 Colour Flex Chart Describing Different Parts Of Acb & Vcb ( 33Kv, 15Mva ) : Size:30× 40, Material: Pvc, With Roller 58 Experiment Kit To Measure Solar Radiation Using Pyranometer On Tilted Surface At Different Angle Inclination: Standard For Laboratory Purpose 59 Colour Flex Chart Describing Different Parts Of Solar Flat Plate Collector & Solar Concentrating Collector & Trough Collector: Size:30× 40, Material: Pvc, With Roller 60 Experiment Kit To Measure Thermal Performance Of Solar Water Heating System: Standard For Laboratory Purpose 61 3D Model Describing Different Parts Of ( I ) Solar Street Lighting System & ( Ii ) 1Kw Small Wind Turbine ( Swt ) : 3D Model For Laboratory Purpose 62 Setup Of 250Wp Solar Pv Plant Including All Accessories: Solar Panel Specifications:Peak Power: 250W; Maximum Power Voltage: 20.2V; Maximum Power Current: 12.38A; Open Circuit Voltage: 23.9V; Short Circuit Current: 13.12A; Power Allowance Range: + / - 3% Hybrid Inverter Specifications: Nominal Battery Voltage: 12V; Continuous Power Output: 1000W / 1000Va; Surge Power: 2000Va Output Voltage: 230V Ac; Output Frequency: 50Hz / 60 Hz; Output Waveform: Pure Sine Wave; Maximum Solar Input Power: 600W; Maximum Open Circuit Solar Input Voltage: 55V; Maximum Solar Charging Current: 50A; Maximum Mains Ac Charging Current: 20A; Maximum Combined Charging Current: 50A; Peak Efficiency: 93% Battery Specifications ( Per Battery ) : Nominal Voltage: 12V; Nominal Capacity: 50Ah ( 10H Rate ) / 55Ah ( 20H Rate ) ; Maximum Charging Current: 25A; Self-Discharging Rate: <3% Per Month; Cycle Lifetime At 30% D.O.D.: 1000-1100 Pressure Control: Safety Valve Installed Terminal Type: F13 ( Bolts And Washers Included ) Operating Temperature: From +10C To +40C 63 Setup Of Small Wind Turbine Plant Including All Accessories: Standard For Laboratory Purpose 64 Study Kit Of Assembling And Dismantling Of Csp Plant Using Parabolic Trough Or Disc: Standard For Laboratory Purpose 65 Study Kit For Assembling Vertical Axis Or Horizontal Axis Swt: Standard For Laboratory Purpose 66 Digital Lcr Multimeter: Digital Lcr Meter ( Battery Operated ) , Model: 4070 Range: 0.1Μh To 20H, 0.1Pf To 2000Μf, 0.1Ohm To 20Mohm Accuracy: 2Mh, Resolution: 1Uh, Accuracy: 20Mh, Resolution: 10Uh, Accuracy: 200Mh, Resolution: 100Uh Accuracy: 2Nf, Resolution: 1Pf, Accuracy: 20Nf, Resolution: 10Pf, Accuracy: 200Nf, Resolution: 100Pf, Accuracy: 2Uf, Resolution: 1Nf, Accuracy: 200, Resolution: ± ( 0.8 Percent+5 ) 0.1, Accuracy: 2K, Resolution: 1, Accuracy: 20K, Resolution: 10, Accuracy: 200K ( Make: Metravi ) 67 Handheld Power Meter Or Power Analyzer With Socket: Voltage: 85V-265V, Current; 0.002A~20A, 50Hz, 1-Ph 68 Analog Power Factor Meter ( 1-Ph & 3-Ph ) : Standard For Laboratory Purpose 69 Multimeter With Clamp Meter Arrangement With Hfe Lcr: Standard For Laboratory Purpose ( Make: Metravi ) 70 Three Phase Power Measurement Kit ( Y & Δ Load R-L Load ) Incl. 3-Ph Wattmeter With 2Kw Range: Standard For Laboratory Purpose 71 Kit For Troubleshooting Single Phase Electronic Energy Meter: 230V, 1-Ph, 50Hz 72 Three Phase Trivector Meter: Salient Features Class 0.5S As Per Relevant Is And Iec Standards 5A Current Rating 3 Phase 4 Wire 4 Quadrant Measurement Anti-Tamper Features Self-Diagnostic Capability Multiple Tariff / Time Of Day Feature Bidirectional Energy Recording Up To 4 Maximum Demand Registers Load Survey ( Interval Data ) Features Up To 12 Reset Backups Optical Port / Rs 232 / Rs 485 / Ir / Irda / Rf ( 2.4 Ghz / 865-867 Mhz ) ( Optional ) ( Make: L&T ) 73 Brake Test Kit Of Dc Series Motor: 220V Dc, 2Hp With Allied Required Accessories 74 Back-To-Back Test Kit Of Single Phase Transformer: 1-Ph, 240V, 50Hz, 1Kva ( 2 Nos. ) Identical Transformers With Other Standard Accessories 75 Isolation Transformer Kit: 230V; 230V / 10Amp 230V; 230V / 5Amp 76 Pulse Transformer Kit: Dc Supply: Two 5V & 12V, Pulse Generator: Two Selectable Frequency & Variable Pulse Width, Mains: 230V / 50Hz, Adequate For Cro Observations, Optocoupler: One, One Ferrite Wired 1:1 77 Colour Flex Chart Describing Different Vector Groups Of Theree Phase Transformer: Size:30× 40, Material: Pvc, With Roller 78 Full-Wave Fully Controlled Bridge Rectifier Kit With & Witout Filter Arrangement: Standard For Laboratory Purpose 79 Kit To Find The Characteristics Of Zener Diode: Standard For Laboratory Purpose 80 Kit To Find The Characteristics Of Mosfet: Standard For Laboratory Purpose 81 Ujt Relaxation Oscillator Trainer Kit: Standard For Laboratory Purpose 82 Singlestatge Transistor Trainer Kit ( Ce-Mode ) : Standard For Laboratory Purpose 83 Trainer Kit For Sr, D, Jk & T – Flip-Flop: Standard For Laboratory Purpose 84 Trainer Kit For Realization Of Encoder And Decoder Circuit: Standard For Laboratory Purpose 85 Trainer Kit For Realization Of Multiplexer And Demultiplexer Circuit: Standard For Laboratory Purpose 86 Trainer Kit For Implementing Dac & Adc: Standard For Laboratory Purpose 87 Connector Cables For Ade Lab. Of Different Types: Standard For Laboratory Purpose 88 Arduino Uno R3 Board With Lcd1602, Servo Motor, Relayes, Processing And C Code, Beginner Starter Kit With Mannual And Allied Accessories: Standard For Laboratory Purpose 89 Trainer Kit For 8051 Μc Programming: Trainer Kit For 8051 Μc Programming With Keypad To Write Program 90 Trainer Kit Using 8051 Μc For Measurement Of Ac Voltage, Current, Frequency & Phase Angle Using Suitable Ct, Pt, Zcd, Adc, Etc. 91 Demonstration Kit For Identifying Pvc, Xlpe, Vir, Catenary, Frls, Frlsh Cables / Wires Of Different Current Rattings: Standard For Laboratory Purpose 92 Megger: Insulation Tester ( 500V ) With Hand-Driven Gen.: 500V, 2500 Mega Ohms 93 Megger: Insulation Tester ( 2500V ) With Hand-Driven Gen. 2.5Kv, 2500 Mega Ohms 94 3-Ph Smart Energy Meter For Lt Power Measurement, 3-Ph, 415V, 4-Wire, Kwh Meter, Current: 10-60A, Class 1.0 Accuracy As Per Relevant Is And Iec Standards, With Lcd Display [ Make: L&T ] 95 Trainer Kit For Dc Chopper Drive With Resistive Load & Dc Separately Excited Motor. 1 / 8 Hp, 200Vdc Operation, Current Limit Protection, Speed Control Using Frequency And Duty Cycle Variation, Jones Chopper Based Control, Motor Loading Arrangement Can Be Provided / Resistive Load May Be Connected, Other Variety Of Controllers With Converter Control With Closed Loop Controller 96 Trainer Kit For Controlling The Speed Of Separately Excited Dc Motor By Changing The Firing Angle Of Scr Using 1-Ph Full Converter. Power Supplies: • Power Supply +15Vat 150Ma • Isolated Supply 0-220V At 5A. • Operated On Mains Power 230V, 50Hz +10% Digital Meters: • Voltmeter 2000V Ac • Voltmeter 2000V Dc • Ammeter 2A Dc Components Are Mounted On The Panels Are: • Scr Tyn604 ( 2 Nos. ) • Diode 1N5408 ( 2Nos. ) • Diode Ba159 • Ac Phase Control By Gate Control Firing Circuit. • Snubber Circuit. Load: • 1 / 2Hp Dc Shunt Motor. • Inductor As Load 230V, 1A • Lamp Load 230V, 60W 97 Μcontroller Based 3-Ph Syn. Motor Drive: Trainer Kit For Controlling The Speed Of Synchronous Motor ( 1Kva ) Drive Using Μc. 98 Demonstartion Kit Showing Different Types Of Power Semiconductor Devices With Heat Shink E.G. Scr, Igbt, Gto, Mosfet, Standard For Laboratory Purpose. 99 Kit For Magnetic Control Of Im: Control And Power Circuit For ( I ) Forward And Reverse Rotation Of Squirrel Cage Im Using Contactor, ( Ii ) Automatic Star-Delta Starter Of Squirrel Cage Im, ( Iii ) Dynamic Braking Of Squirrel Cage Im, Standard For Laboratory Purpose. 100 Screw Driver Set, Standard For Laboratory Purpose. 101 6” Slide Range, Standard For Laboratory Purpose. 102 Wire Stripper, Standard For Laboratory Purpose. 103 Crimping Tool ( 1 Sq. Mm. To 6 Sq. Mm. ) . 104 2.5 Sq. Mm. Stranded Pvc Copper Wire 105 1.5 Sq. Mm. Stranded Pvc Copper Wire 106 1 Sq. Mm. Stranded Pvc Copper Wire 107 Soldering Kit: 20W With Solder Material 108 Contact Type Tachometer ( Range: 0-10, 000 Rpm ) 109 Set-Up With Different Type Tl Lamps ( Conventional & Led ) With Fittings Containing Electrimagnetic Ballast / Electronic Ballast Etc.: Tl Fittings With: 1. Electronic & Electromagnetic Ballast For ( I ) Single 40W, 240V, 50Hz Tl, ( Ii ) 2X40w, 240V, 50Hz Tl, 2. 20W Led Tl With Fittings Incl. 110 3-Ph Capacitor Bank Of 2-4Kva For Correcting Power Factor Of 415V, 50Hz, 1500 Rpm, 2Hp, 3-Ph Squirrel Cage Im With Facility To Connect The Stator Of The 3-Ph Im Both In Star & Delta Mode And A Tri-Vector Meter Having Facility To Measure Kw, Kva, Kwh, Kvarh, Pf. 111 Transformer Oil Breakdown Strength Kit: Breakdown Strength Kit With 5 Ltr. Fresh Transformer Oil, Standard For Laboratory Purpose. 112 Chart For Demonstration Of Different Fire Extinguishers: Colour Flex Chart Describing Different Types Of Fire Extinguishers ( 4 X 3 ) , Material: Pvc, With Roller 113 Chart For Demonstration Of Artificial Respiration ( Cpr ) And Prepare A Report.: Colour Flex Chart Describing Different Types Of Artificial Respiration ( Cpr ) ( 4 X 3 ) , Material: Pvc, With Roller.
Contract Date: Dec 10, 2024 Contract Value : 11.21 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
11.
Heavy Industries and Public Enterprises #10706525 Price Bid
Tender For Selection Of An Event Management Agency ( Ema ) For Inauguration Of India International Convention Centre ( Iicc ) , Dwarka, New Delhi; 1 Havan At Foyer Area 2 Havan Kund, Havan Samagri And Pandit For Havan Rituals 3 Centre Thematic Setup Of Size 10M X 10M For Havan Rituals 4 Wooden Chairs 5 Cocktail Tables For Hi-Tea Arrangements 6 Buffet Counters With Frill For Hi-Tea Arrangement 7 Q Managers 8 Floral Decoration At Foyer Area ( High Quality Fresh Flowers ( Cosmos Flower, Gaillardia Flower, Zinnia Flower, Dahlias Flower, Peonies Flower, Fox Brush Orchids Flower, Tulips Flower, Gloriosa Lily Flower, Pineapple Lily Flower, Rain Lily Flower, Flower, Roses- Different Colour, Carnations Flower, Birds Of Paradise ) . Theme Of Floral Decoration To Be Presented In Technical Presentation. 9 2.6Mm Led Screens Of Size 16 X 12 For The Various Locations With Sound Facility 10 Riser Of Size 12 X 4 X 26 With Branding And Side Black Masking For Led 11 Sound System Of Havan Rituals For 200 Pax With Mics 12 Digital Photographers For Havan 13 Digital Videographers For Havan 14 Genset For Other Leds And Other Requirements, Including Distribution 50 Kva Along With Diesel 15 Hi-Tea Arrangements, Including Tea / Coffee, Snacks, Etc. From A Reputed 5-Star Hotel 16 Main Event Area / Auditorium 17 2.6Mm Led Wall Of Size 100 Ft X 35 Ft For Stage Backdrop 18 Led Riser: 100 X 4 X 6 Inches High With Ply On Top, Carpet , Setup In The Main Auditorium. 19 Scaffolding Structure For Led Support 100 X 24 20 Flower Decoration On Stage. 21 Thematic Wall Of Size 20 Ft X 35 X 2 Numbers On Both Side Of Led Wall, Including Necessary Scaffolding 22 Hiring Of Show Running Team And Technical Team- Show Running Of The Entire Unveiling And Launch Ceremony Including Technical Coordination And On-Stage Flow 23 Additional Lights For Foh - Moving Heads 32, Wash - 24, Rgb Led -24 24 Techrider For Culture Artist And Other Artists 25 Sofa Seat ( High-End ) Mix Of 1, 2-, 3- And 5-Seater Sofas 26 Mozo Barricading / Fencing 27 High Platform For Media, Console And Camera Etc. 28 Mozo Barricading In Front Of Stage In D Shape For Hon’Ble Pm 29 Lightening Of Lamp By Vip 30 Q Manager 31 Genset For Main Stage Led, Including Distribution 32 ( 250 Kva+125 Kva Genset 375 Kva With Dieselups For Main Stage Led 375Kva 33 F&B Area 34 Buffet Counters With Masking & Frill 5Rft 35 5 Round Tables With 8 Banquet Chairs With High-Quality Linen 36 Cocktail Tables 37 Flower Decoration In Both Food Courts 38 Glass Water Bottles - Minimum 200 Ml 39 Hi-Tea Arrangements, Including Tea / Coffee, Snacks, Etc. From A Reputed 5 Star Hotel 40 Media Lounge 41 Media Lounge To Be Constructed In Hangar With Air- Conditioning, Platform, New Carpet, Lighting, Electrical Outlets, The Lounges To Have Acoustic Walls, Ceiling, Pantry With Serving Facility And Storeroom 42 Power Back-Up Dg For Media Lounge With Diesel 300Kva 43 Vip Toilets For Media Lounge 44 Facility For Live Telecast Of The Inaugural, Valedictory And Sectoral 45 Sessions In The Media Lounges. 46 Workstation With Seating Arrangements, Electric Sockets 47 Sofa Seating ( 2+1+1-Seater ) 48 Centre Tables 49 Chair For Round Table Sitting 50 Round Tables 51 Pigeonhole Rack 52 Laptop / Mobile Charging Stations 53 Computers For Media Workstations With B / W , Color A4 Size Printers 54 Stationary For Media Lounge 55 Decoration 56 Florals In Different Area ( High Quality Fresh Flowers ( Cosmos Flower, Gaillardia Flower, Zinnia Flower, Dahlias Flower, Peonies Flower, Fox Brush Orchids Flower, Tulips Flower, Gloriosa Lily Flower, Pineapple Lily Flower, Rain Lily Flower, Flower, Roses- Different Colour, Carnations Flower, Birds Of Paradise ) . 57 Logo Theme Flags 58 Appropriate Landscaping With Plants Across The Event Venue, Ensuringoverall Ambience Decor. 59 Gallery Showcasing Neo Bharat Theme 60 Setting Up For A Special Thematic Showcase / Gallery Area For Vip Walkthrough, Depicting Journey Of Iicc And India Milestones. Displays To Include 3D Cutouts, Printed Panels, Av Screens, Plasma Screens, And Tech Engagements Arranged In Aesthetic Manner. Theme Should Be Revolving Around Neo Bharat. 61 Carpeting In Open Area / Foyer Area 62 Coir Carpeting ( New ) And Maintenance Of The Carpet To Be Done. Red Carpeting ( New ) In Pathways / Approach Routes Taken By Vvip , VipS Within Convention Centre And Outside The Venue, Inside Dmrc 15000 Sqft 63 Thematic Gate 64 Main Thematic Gate Of Length 60- 80 Ft And Height 30-40 Ft. The Gate Should Be Made Using Different Material Like Wood, Pop, Fibre, Raisins, Brandings, Flex, Acrylic, And Outer Cut Letterings, High Quality Paint And Material Finishes, Metal Works Depicting The Theme Proposed. 65 Small Gates Depicting The Theme Of Length 20-30 Ft And Height 12-16 Ft. The Gate Should Be Made Using Different Material Like Wood, Pop, Fibre, Raisins, Brandings, Flex, Acrylic, And Outer Cut Letterings, High Quality Paint And Material Finishes, Metal Works Depicting The Theme Proposed. 66 Emergency / Miscellaneous Services 67 Control Room For Fire, Disaster Management Etc. In Form Of A Hangar And General Lighting For Officers For Various Services. 68 Medical Hangar With Air- Conditioning, Platform, New Carpet, Lighting, Electrical Outlets, Acoustic Walls, Storeroom, And Toilet Facility. Provision For Partition For Patient Rooms ( 10 Nos. ) , Seating Arrangement ( 05 Tables, 20 Chairs ) For Medical, Support Staff And Reception Area. 69 Power Back-Up Dg For Control Room And Medical Hangar 50 Kva With Diesel 70 Event Branded Pagodas ( 3X3 Sqm ) For Various Purposes Consisting Of Two Tables And Four Chairs Including Platform, Carpet, Dustbin, And Electrical Points. 71 Branding 72 Buntings, Banners, Scrollers, Etc. Of Appropriate Sizes At Various Locations At The Venue, As Well As Throughout The Prominent Places Of New Delhi Using Appropriate Eco-Solvent Printing Materials, Hoardings, Key Locations Shall Be Updated By Ema 73 Digital Signages For The Different Areas 74 Flex Iron Mounted Of Different Sizes In The Venue, Outside Venue And Within Dmrc Route Using Appropriate Eco-Solvent Printing Materials 50 Nos 75 Logo Of Iicc Needs To Be Installed At Various Locations Inside The Venue Of Various Sizes, Using Different Material Like Wood, Pop, Fibre, Acrylic, And Outer Cut Letterings, High Quality Paint And Material Finishes, Metal Works Etc Of Different Sizes. 8X4 , 12X08, 20X12. 76 General Lighting 77 For The Entire Event Venue On Light Poles, Each Light Pole Having Of 150 Watts Metal Halide / Led Light / Rgb Light Rates Will Be Inclusive Of Wiring From The Source To Consumption Point Through Underground Cabling. 78 Collaterals 79 Invitation Design & Cards Printing With Qr Code 80 Car Stickers 81 Shuttle Stickers 82 Badges 2 Sided Printed With Punch Hole On 2 Sides & Lanyards For Organizers, Delegates, Artisans. 83 Badges & Lanyards For Volunteers / Working Team 84 Golf Carts 85 6-Seater Golf Cart With Driver And Charging Facility. 86 Shuttle Buses Electric Or Cng , 20 Seater Or Above 87 Innova Crysta Cars 88 Parking Area & Management 89 Parking Area To Be Created For 2000 Cars In The Designated Zones Per Site Layout With Proper Markings, Signages, Control Booth, Tin Barricading, Lighting, And Manpower To Control The Traffic Movement. 90 Event Branded Gate ( 24 Ft. X 18 Ft. ) For Different Parking Areas 91 Pa System For Announcements In Parking Area 92 Manpower 93 Emcee Who Would Be Proficient In Hindi And English, Artist Management, Logistics And Etc. 94 Visitor Management Including Hostesses, Volunteers, Helpers, Stage Coordinators, Hospitality Managers, Etc. Provide Uniformed And Well-Dressed Ushers On The Days Of The Event. 95 Photography & Videography 96 Complete Photography Setup ( 3 Nos ) , Videography Setup ( 5 Nos ) Using High End Cameras With Hd Live Mixing Unit, 36 Out Audio Video Di Box 97 Live Streaming Of The Entire Event, Live Relay Across All The Areas With Provision For Live Feed. 98 Multi Camera Videography With Zip Crane 99 Digital Photographers 100 Digital Videographers 101 Security Arrangements 102 Supplying, Installation And Maintenance Of Door Frame Metal Detector Machines For Entry Points, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan, 103 Supplying, Installation And Maintenance Of Handheld Metal Detector Machines With Adequate Manpower For Entry Points, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan. 104 Supplying, Installation And Maintenance Of Walky-Talky For The Entire Team, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan. 105 Supplying, Installation And Maintenance Of Baggage, Thermal Scanners Scanning Machines With Adequate Manpower For Entry Points, For The Entire Event Duration At The Venue, As Approved By The Security Management Plan. 106 Frisking Booth For Females With Curtains 107 Complete Coverage Of Venue With Moveable And Zoomable Cctv Cameras With Monitoring Setup. 108 Human Resource Deployment 109 Security Personnel With Uniform For 24X7 Surveillance Male & Female 110 Housekeeping Team 111 Sanitization And Pest Control Of The Complete Convention Centre & Foyer Area , 3 Times In A Day, 3 Days Before The Event 112 Toilets 113 Bio-Chemical Toilet ( Male & Female ) 114 Safe Room 115 Safe Room For Vvip Around The Stage At Inaugural Hall Which Would Include Sofas, Chairs, Teapoy Tables, Flower Decoration, Water Bottles, Platform, Carpeting. ( 100 Sqm ) 116 Installations 117 Installations ( 490 Sqft ) To Serve As A Photo Opportunity; Well- Integrated On The Theme Of The Event And To Be Erected At The Most Suited Location At The Event Venue, For Maximum Engagement, Locations Needs To Be Mentioned In The Presentation 118 Miscellaneous 119 Wheelchair 120 Stone Plaque 121 Sitting Arrangement For All The Halls ( Carnation, Laburnum, Meeting Rooms At 3Rd Floor Aster Hall, Petunia Hall, Tulip Hall, Zinnia Hall, Daffodil Hall, Vvip Lounge, Furniture Lobby Area Furniture, Auditorium Area Furniture, Green Room & Artist Room Furniture, Etc ) - 2000 Pax 122 Green Room 123 Mirror In The Room For Artists 124 Table 125 Chairs 126 Cloth Hangars 127 Social Media Publicity 128 1 Content Development As Required By The Authority 2. Creation Of Event Specific Pages / Handles On Social Media3. Developing Social Media Strategy In Accordance With The Approved Branding And Publicity Plan 129 Vc Av Requirement For HonBle Pm 130 Hardware ( H.323 / Sip ) Videoconferencing System Configuration. Make: Videoconferencing Equipment Like Cisco / Poly / Panasonic Or Equivalents 131 Dedicated Lease Line Of 100 Mbps With 100 Mbps Dedicated Backup With A Different Isp Provider 132 Suitable Interface Converters To Connect Camera With Videoconferencing Systems Through Hdmi Input Supporting 1080P60 / 1080P30 133 Multiple Professional Full Hd Video Cameras With Live Mixing Setup 134 Photographers 135 Live Mixing Setup 136 Console Setup, Including Tables, Chairs, Black Masking 137 Stone Plaque => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
12.
Science and Technology #10497935 Price Bid
Tender For Annual Maintenance Contract Of Lab Buildings Of Iip. ( Electrical Works ) 2022-23. -Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5Sqmm Frls Pvc Insulated Copper Conductor Single / Multi Core Cable In Surface / Recessed Steel Conduit Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point / With 1.5Sqmm Fr Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit ( Akg / M-Key ) , With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. 2 Group-A 3 Wiring For Circuit / Submain Wiring Along With Earth Wire The Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit ( Akg / Plaza / Kaliga ) As Required 4 2 X 1.5 Sq Mm + 1X 1.5 Sq Mm Earthwire 5 2X2.5 Sq Mm + 1X2.5 Sq Mm Earth Wire 6 2X4 Sq Mm +1X4 Sq Mm Earth Wire 7 2X6 Sq Mm + 1X6 Sq Mm Earth Wire 8 4 X 4 Sq Mm + 2X 4 Sq Mm Earth Wire 9 Supplying And Drawing Following Sizes Of Fr Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( Havells / Polycab ) 10 3 X 1.5 Sq Mm 11 3 X2.5 Sq Mm 12 3 X 4 Sq Mm 13 3 X 6 Sq M 14 Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed / Pvc Conduit As Required. 15 2 Pair 16 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recessed Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( Akg / M-Key ) 17 20 Mm 18 25 Mm 19 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recessed Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. ( Akg / M-Key ) 20 20 Mm 21 25 Mm 22 Supplying And Fixing Metal Box Of Following Size ( Nominal Size ) On Surface Or In Recessed With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc As Required. 23 100 Mmx 100 Mmx 60 Mm Deep 24 180 Mmx 100 Mmx 60 Mm Deep 25 200 Mmx 125 Mmx 60 Mm Deep 26 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc As Required. 27 5 / 6 Amps Switch 28 2 Way 5 / 6 Amps Switch 29 15 / 16 Amps Switch 30 3 Pin 5 / 6 Amps Socket Oulet 31 6 Pin 15 / 16 Amps Socket Oulet 32 Supplying And Fixing Following Piano Type Switch / Socket On The Existing Switch Box / Cover Including Connections Etc As Required. 33 5 / 6 Amps Switch 34 2 Way 5 / 6 Amps Switch 35 15 / 16 Amps Switch 36 3 Pin 5 / 6 Amps Socket Oulet 37 6 Pin 15 / 16 Amps Socket Oulet 38 3 Pin 5 / 6 Amps Socket Oulet 39 Supplying And Fixingtwo Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required 40 Supplying And Fixingfollowing Size / Modules, Gi Box Along With Modular Base & Cover Plate For Modular Switch In Recess Etc As Required 41 1 Or 2 Module ( 75 Mm X 75 Mm ) 42 3 Module ( 100 Mm X 75 Mm ) 43 6 Module ( 200 Mm X 75 Mm ) 44 8 Module ( 125 Mm X 125 Mm ) 45 12 Module ( 200 Mm X 150 Mm ) 46 Supplying And Fixing Following Metal Box Of 180Mm X 100Mm X 60Mm Deep ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Fornt Including Providing And Fixing 6Pin 5A & 15 A Socket Outlet And 15 A Piano Type Switch, Connection, Painting Etc. As Required . 47 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 6 Pin 5 / 6 And 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required 48 Supplying And Fixing 3 Pin, 5A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required 49 Providing And Fixing Plain 16 / 0.20Mm ( 0.50Sqmm ) Twin Flat Flexible, Frls Pvc Insulated, Copper Conductor Cable, In Pvc Sleeve Of Suitable Size On The Floor / Wall, Or Side Of The Table / Door Etc. As Required. 50 Installation, Testing And Commissioning Of Pre-Wired Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Compelete With All Accessories And Tube Etc.Directly On Ceiling / Wall, Including Connection With 1.5 Sq Mm Fr Pvc Insulated Copper Conductor, Single Core Cable And Earthing Etc. As Required. 51 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rod Of Standrand Lenght ( Up To 30Cm ) With 1.5 Sq.Mm Fr Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required 52 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc As Requied Upto 450 Mm . 53 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 54 1 Run Of Cable 55 Providing And Fixing Following Rating And Breaking Capacity Mccb In Existing Cubical Panel Board Including Drilling Holes In Cubical Panel, Making Connections Etc As Required 56 200 Amp, 25 Ka, Tp Mccb 57 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415V Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200A, Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mountingmcbs ( But Without Mcbs And Incomer ) As Required 58 12 Way, ( 4 + 36 ) Double Door 59 Supplying And Fixing 5 Amps To 32 Amps Rating, 240V / 415V, C Curve, Miniture Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connection, Testingand Commissioning Etc. As Required 60 Single Pole 61 Single Pole And Neutral 62 Double Pole 63 Tripple Pole 64 Tripple Pole And Neutral 65 Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connetionx, Testing And Commissioning Etc. As Required. 66 40 Amps 67 63 Amps 68 Supplying And Fixing Following Rating, Four Pole, 415V, Isolator In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc. As Reqired. 69 40 Apms 70 63 Apms 71 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In Existing Rcc / Hume / Metal Pipe Etc. As Required. 72 Upto 35 Sq Mm 73 Above 35 Sq Mm And Upto 95 Sq Mm 74 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size In Existing Masonry Open Duct As Required Etc. As Required. 75 Upto 35 Sq Mm 76 Above 35 Sq Mm And Upto 95 Sq Mm 77 Laying And Fixing Of One Number Pvc Inslulated And Pvc Sheated / Xlpe Power Cable Of 1.1Kv Grade Of Following Size On Wall Surface As Required. 78 Upto 35 Sq Mm ( Clamped With 1Mm Thick Saddle ) 79 Above 35 Sq Mm And Upto 95 Sq Mm ( Clamped With 25X3mm Ms Flat Clamp ) 80 Above 95 Sq Mm And Upto 185 Sq Mm ( Clamped With 25 / 40X3mm Ms Flat Clamp ) 81 Supplying And Fixing 32 / 40 Mm Dia X 2.00 Meters Long G.I Pipe ( Meidum Class ) Bracket For Mounting Of Fiuorscent / Hpmv / Hpsv Street Light Fitting On Pole Including Bendingshape, 2 Nos. 40 Mmx 3Mm Flat Iron Clamps With Nuts, Bolts Andthe Pipe To The Require Washer, Painting The Flat Iron Primer And Finish Piant Etc As Required. 82 Supplying And Laying Of Following Sizedwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc.Conforming Tois 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 83 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 84 Supplying, Installation, Testing And Commissioning Of Passive Infrared ( Pir ) Technology Base Occupancy Sensor Having High Preformance, Non Regulating Programmable Type, Suitable For Connected Load Upto 10A, For Mounting Height Up To 2.8 Meter And 5 Meter Diameter Coverage Area Along With Necessary Fixing Arrangements I / C Programming At Site Complete As Required. 85 Supplying, Installation, Testing And Commissioning Of Astronomical Time Switch Of Following Configuration To Be Mounted In Feeder Pillars / Lighitng Dbs For Automatic Switching On & Off Of Street Lights At Sun Set & Sun Reise Or Twilight ( Auto On, Off, Auto Modes ) With Manual Override Facility With 12 / 24 Hour Display Format With Suitable Battery And Indication For Relay Status I / C Programming At Site Complete As Required. 86 1 Out Put Per Phase Suitable For Single Phase Supply 87 Supply Of Labour For Attending Day To Day Complaints Complaints Of Electrical Maintenance Work For Repair And Replacement Of All Electrical Accessories In Non Workingelectrical Fittings And Fixture ( Such Main Boards, Fans, Geysers Switches, Sockets, Light Fittings, Motors, Starters, Street Light, Energy Meters In Lab Buildings, Underground And Overhead Line Distribution Network Including Service Main, Operation And Maintenance 33Kv 044Kv Substation And Power House ( 24 Hour Round The Clock ) All Other Electrical Work As Assigned By Site-Incharge. 88 Skilled Labour In Electrical Trade 89 Unskilled Labour In Electrical Trade 90 Attending Day To Day Complaints Of No Light / Non Working Points / Providing Temporary Connections In Iip Lab Buildings, Hostel & Guest House Etc As Required. 91 Supplying And Fixing Rj45 Outlet Information Module In Exsiting Modular Box Etc As Required. 92 Supplying And Fixingmodular Surface Mount Box With Modular Plate For Telephone Wiring With Telephone Deluxe Jack Single Outlet On Surface Or In Recessed Etc As Required. 93 Supplying, Fixing And Commissioning Of Heavy Duty Exhaust Fan Of 380 Mm Sweep 900 / 1400 Rpm / Turbojet Sp, Hd Suitable For 230V 50Hz Ac Supply Complete With Blade, Regular, Frame And Moving System Etc As Required .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 94 Supplying Of Ceiling Fan Of 1400 Mm Sweep, With Heavy Fins , High Quality Engineering, Energy Saving, Decorative Pacer Model ( White / Brown / Lovery ) Suitable For 230 V, Single Phase, 50 Hz Supply Including 600 Mm Long Down Rod And Electronic Regulator Etc…As Required. The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 95 Supplying And Laying Of Following Size Isi Marked Pvc Insulated And Pvc Sheathed / Xlpe / Frls Aluminium Conductor Steel Armoured Alumimium Cable Of 1.1Kv Grade As Required. 96 2 X 16 Sqmm 97 Supplying And Fixing Following Rating 415 / 230V C Series, Miniture Circuit Breaker Suitable For Lighting And Other Load Of Following Poles In The Existing Mcb Db Complete With Connection, Testing And Commissioning Etc As Required 98 Double Pole, 63 Amps 99 Tripple Pole And Neural, 63 Amps 100 Supply And Fabrication Of Sheet Steel Mcb Enclosure Fitted With Din Rail For Mcb Of Following Rating Complete With Connections Including Drilling Holes Etc As Required. 101 Double Pole Enclosure 102 Four Pole Enclosure 103 Supplying And Fixing 8 Module Flush Box Of 210 Mmx 75 Mm Size On Surface Or Recessed With Suitable Size Of 8 Module Front Sheet Cover In Front Including Providing And Fixing 6A, 5 Pin Module Socket 02 Nos And 6-16A, 3Pin Combined Modular Socket 01 No 10 A Sp Mini Mcb -01 No Etc As Required 104 Supplying And Fixing 6 Module Flush Box Of 200 Mm X 75 Mm Size On Surface Or Recessed With Suitable Size Of 6 Module Front Sheet Cover Of Make In The Front Including Providing And Fixing 20A One Way Modular Switch 02 Nos And 6-16 A, 3 Pin Combined Modular Socket 02 No Connecton, Painting Etc As Required. 105 Supply And Replacemant Of Capacitor Of Ceiling Fans / Exhaust Fan / Wall Fan / Padestal Fan Of Size Of 2.5 To 4 Mfd Etc As Required 106 Supply & Replacement Of 16 Amp. Plug Top, 3 Pin ( Crabtree / Anchor ) 107 Supply & Replacement Of 6 Amp. Plug Top, 3 Pin ( Crabtree / Anchor ) 108 Supply And Fixing Of Following Led Energy Saving Surface / Pendent Mounting Led Lamp Fitting With Powder Coated / Batten With In Bulit Electronic Ballast With Decortive End Caps Etc. As Required. 109 1 X 4 X 20W Led Luminaries With Tube Rod. 110 2 X 4 X 20W Led Luminaries With Tube Rod. 111 Supplying And Fixing Following High Efficiency Led Tube Rod Lamps Led Luminaire In Existing Fitting Fixture With Connection Etc. As Required. 112 4 X 20W Led Luminaries Tube Rod. 113 Supplying And Fixing Led Tube Rod 18 Watt 2 Feet Single Side Connection Ultra Bright Led Polycarbonate Tube Rod With High Efficinsyfor Installation In Exiisting Suitable Fittings. 114 Overhauling, Rewinding Oiling Greasing Of Ceiling Fan / Exhaust Fan / Pedsetal Fan / Wall Fan Of Any Size Including Supply And Replacement Of Ball Bearing / Bush Capacitor , Split Pin Rubber Wire, Shaft, Nut & Bolt 2X1.5 Sqmm Copper Connecting Wire, Cleaning Varnishing , Revolving Attechment And Step Regulator With Resistence Of Wall And Pedestal Fan Etc Complete In All Respect As Required. 115 1400 Mm Ceiling Fan Rewinding 116 Supply And Commissioning Of Indoor Recess / Surface 600X600mm ( 2X2 ) Led Luminaire 42W With High Luman Package Etc As Required.The Product Features Special Glare Cut Optics To Ensure Low Luminaire Luminance And Is Perfect For General And Office Lighting Applications Such As Workstations, Meeting Rooms And Cabins, Corridors And Break Areas. ( Havells / Wipro / Philiphs / C&S ) The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 117 Supplying And Fixing 15 Watt, 6000K New Generation Led Post Of Lanturn Light Luminare Ip 65, Energy Saving, Enviornmental Friendly, Long Life Aesthetically Designed With Symmetrical Light Distribution, Spun Aluminium Lad Scape Luminaire With High Power Leds As Light Souce. Clear Cover Offers Bright Illumination For Different Application. ( Havells / Wipro / Philiphs / C&S ) . The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 118 S / R Of Following Watt Led Strret Luminaire, New Genration Energy Savin And Enviornmental Friendly Long Life Led Street Light Made Uo Of Pressure Die Cast Aluminium Housing With High Efficiency Led S Lighting Source And Toughened Glass Having Bottom Opening Seperate Driver Compartment With Ip 66 Protection And Impact Resistance Of Ik07. ( Bajaj / Havells / Philiphs / Wipro ) . The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 119 25 Watt Led Luminaire 120 30 W Led Luminaire 121 Supplying And Fixing Surface / Recess Mounting Led Panel Fitting Fixture 10 W ( 1X 1 ) , Elegantly Designed Sleek Recessed Mounted Pressure Die- Cast Alumium Luminaire In Powder Coated White Finish In Square Profile With Optimized Heat Sink For Efficient Heat Dissipation And Indepndent Elctronic Led Driver With Connection All Etc As Required. The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 122 Supplying And Drawing Folowing Size Of Pvc Insulated Aluminium Flat Twin Core Weather Proof Cabe In Existing Pipe Or Surface Etc As Required. 123 2X 4Sq Mm 124 2X6sq Mm 125 Supplying Of Wall Fan Of 400 Mm Sweep, 5 Star , Energy Saving, Decorative Pacer Model ( White / Brown / Lovery ) Suitable For 230 V, Single Phase, 50 Hz Supply Including All Etc…As Required. ( Havells / Bajaj / Usha ) .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 126 Supplying And Fixing 50 W Turbo Led Floodlight Luminaure, Energy Saving, Enviornmental Friendly, Long Life, One Desig For Aesthetic Consistancy In Multi Purpose Application With Smd Leds As Light Source With Driver Included, Suitable For Highliting Architectural Features Or Area Lighting. Also Suitable To Rough Services / Installations. ( Bajaj / Philiphs / Havells / Wipro ) .The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 127 Supplying And Fixing Of Monkey Guard Fixtures ( Iron / Steel Cover ) For Protection Of Post Of Lanturns Light Fitting With All As Required. Material Designing Must Be Discussed With Enginer In Charge And Before Supplying Its Design Approval Must Be Taken By Engineer In Charge. 128 Providing And Fixing 9 Watt Retrofit Led Bulbs For Guest House Etc…As Required. 129 Supply, Fixingand Commissioning Of Indoor Recess / Surface 160X160mm ( 1X1 ) A L.E.D. Panel Light 18 Watt Equipped With Motion Sensor, Will Work Only At 3.5 Watt / Go Off When Nobody Is Around The Light. Will Go To 18 Watt At Full Intensity As Soon As Any Motion Occurs Around Light . Saves About 75% Electricity With All Acceossiers Etc. As Required.The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site. 130 Supply, Fixingand Commissioning Of Indoor Recess / Surface A L.E.D. Panel Light 12 Watt Equipped With Motion Sensor, Will Work Only At 3.0 Watt / Go Off When Nobody Is Around The Light. Will Go To 12 Watt At Full Intensity As Soon As Any Motion Occurs Around Light. Saves About 75% Electricity With All Asseossries Etc. As Required.The Same Will Be Inspected And Aproved By Engineer-In-Charge Before Its Dispatch From Factory To Site.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttarakhand View Result →
13.
Health and Family Welfare #10492853 Price Bid
Repair Of Hospital Furniture, General Purpose Medical And Electrical Items - Steel Bed 2 A ) Spray Painting Per Unit 3 B ) Tightening Of Bed 4 C ) Welding Per Point 5 D ) Nut & Bolt 6 E ) Rubber Shoes 7 F ) Replacement Of Bed Panel Sheet Per Square Feet 8 Fowler Bed 9 A ) Spray Painting Per Unit 10 B ) Tightening Of Bed 11 D ) Welding Per Point 12 E ) Nut & Bolt 13 F ) Replacement Of Rubber Wheel Per Inch 14 G ) Repair Of Lifting System 15 H ) Providing Of Key 16 I ) Replacement Of Wheel Caster Per Inch 17 Wheel Chair 18 A ) Spray Painting Per Unit 19 B ) Replacement Of Cushioned Seat Or Back Per Inch 20 C ) Repair Of Rim 21 D ) Replacement Of Axle 22 E ) Replacement Of Broken Spoke Per Piece 23 F ) Replacement Of Cone Katori 24 G ) Replacement Of Hub 26X1.5 25 H ) Replacement Of Handle Grip 26 I ) Repair Of Foot Step 27 J ) Welding Per Point 28 K ) Replacement Of Sated Tyre 26X1.5 29 L ) Canning Of Seat Or Back 30 M ) Replacement Of Steel Balls Per Ball 31 N ) Replacement Of Wheel Caster Per Inch 32 O ) Replacement Of Wheel Rubber Per Inch 33 Patient Trolley 34 A ) Spray Painting Per Unit 35 B ) Replacement Of Wheel Caster Per Inch 36 C ) Replacement Of Rubber Wheel Per Inch 37 D ) Nut & Bolt 38 E ) Fixing Of Bush Pipe 39 F ) Welding Per Point 40 Bed Side Locker 41 A ) Spray Painting Per Unit 42 B ) Adjustment Of Front Door 43 C ) Replacement Of Kunda / Kabza / Chapka 44 D ) Buffing &Polishing Of Top 45 E ) Replacement Of Ss Top Per Square Feet 46 F ) Replacement Of Front Door 47 G ) Welding Per Point 48 Dressing Drum 49 A ) Buffing & Polishing 50 B ) Repair Of Central Belt 51 C ) Replacement Of Kunda / Kabza / Chain 52 D ) Rivet 53 E ) Welding Per Point 54 Office Table 55 A ) Spray Painting Per Unit 56 B ) Welding Per Point 57 C ) Replacement Of Lock With Fitting 58 D ) Providing Of Key 59 E ) Repair / Adjustment Of Drawer 60 F ) Replacement Of Drawer 61 G ) Replacement Of Rubber Shoes 62 I ) Replacement Of Sunmica Top Per Square Feet 63 Screen 3 Fold Or 4 Fold 64 A ) Spray Painting Per Unit 65 B ) Replacement Of Wheel Caster Per Inch 66 C ) Replacement Of Wheel Rubber Per Inch 67 D ) Providing Of Curtain Spring Wire Per Feet 68 E ) Welding Per Point 69 Filling Cabinet 70 A ) Spray Painting Per Unit 71 B ) Replacement Of Lock 72 C ) Repair / Adjustment Of Drawer 73 D ) Welding Per Point 74 E ) Replacement Of Steel Ball 75 Foot Step Single / Double 76 A ) Spray Painting Per Unit 77 B ) Replacement Of Rubber Shoe 78 C ) Replacement Of Foot Rubber Mat 79 D ) Welding Per Point 80 Steel Almirah Small / Big 81 A ) Spray Painting Per Unit 82 B ) Repair Of Locking System 83 C ) Replacement Of Lock With Key 84 D ) Replacement Of Handle 85 E ) Adjustment Of Shelf 86 F ) Replacement Of Leg Bottom 87 G ) Replacement Of Bhogll 88 H ) Replacement Of Rivet 89 I ) Replacement Of Screw 90 J ) Providing Of Key 91 K ) Welding Per Point 92 Revolving Stool 93 A ) Spray Painting Per Unit 94 B ) Adjustment Of Revolving Stool 95 C ) Replacement Of Rubber Shoes 96 D ) Welding Per Point 97 E ) Replacement Of Steel Top Per Square Feet 98 Wheel Barrow 99 A ) Spray Painting Per Unit 100 B ) Replacement Of Central Rod 101 C ) Replacement Of Wheel Rubber Per Inch 102 D ) Nut &Bolt 103 E ) Providing Of Iron Sheet Per Square Feet 104 F ) Welding Per Point 105 G ) Adjustment Of Front Door With Chapka 106 H ) Replacement Of Wheel Castor Per Inch 107 Iv Stand 108 A ) Spray Painting Per Unit 109 B ) Replacement Of Wheel Caster Per Inch 110 C ) Replacement Of Rubber Wheel Per Inch 111 D ) Replacement Of Knob 112 E ) Welding Per Point 113 F ) Replacement Of Steel Rod With Hook 114 Overhead Bed Table 115 A ) Spray Painting Per Unit 116 B ) Replacement Of Wheel Caster Per Inch 117 C ) Replacement Of Rubber Wheel Per Inch 118 D ) Replacement Of Rubber Shoe 119 E ) Replacement Of Bush Pipe / Support Leg 120 F ) Welding Per Point 121 Basin Stand 122 A ) Spray Painting Per Unit 123 B ) Replacement Of Wheel Caster Per Inch 124 C ) Replacement Of Rubber Wheel Per Inch 125 D ) Welding Per Point 126 Steel Chair 127 A ) Spray Painting Per Unit 128 B ) Replacement Of Seat Or Back 129 C ) Replacement Of Wooden Handle Per Piece 130 D ) Providing Of Support Patty 131 E ) Screw / Nut &Bolt 132 F ) Replacement Of Rubber Shoe / Rubber Base 133 G ) Welding Per Point 134 H ) Canning Of Seat Or Back 135 Steel Rack 136 A ) Spray Painting Per Unit 137 B ) Adjustment Of Shelf 138 C ) Nut & Bolt 139 D ) Welding Per Point 140 Oxygen Cylinder Trolley 141 A ) Spray Painting Per Unit 142 B ) Replacement Of Wheel Caster Per Inch 143 C ) Replacement Of Rubber Wheel Per Inch 144 D ) Adjustment Of Patti 145 E ) Replacement Of Base Sheet 146 F ) Welding Per Point 147 Book Case 148 A ) Spray Painting Per Unit 149 B ) Replacement Of Glass Per Square Feet 150 C ) Replacement Of Handle Per Piece 151 D ) Replacement Of Lock 152 E ) Welding Per Point 153 Surgeon Locker 154 A ) Spray Painting Per Unit 155 B ) Repair Of Lock 156 C ) Replacement Of Lock With Key 157 D ) Replacement Of Leg Bottom 158 E ) Adjustment Of Door 159 F ) Replacement Of Kundi / Kabza 160 G ) Welding Per Point 161 Instrument Cabinet 162 A ) Spray Painting Per Unit 163 B ) Replacement Of Glass Per Square Feet 164 C ) Replacement Of Handle Per Piece 165 D ) Repair Of Lock 166 E ) Replacement Of Lock With Key 167 F ) Welding Per Point 168 Dressing / Medicine Trolley 169 A ) Spray Painting Per Unit 170 B ) Replacement Of Wheel Caster Per Inch 171 C ) Replacement Of Rubber Wheel Per Inch 172 D ) Fixing Of Bush Pipe 173 E ) Replacement Of Ss Top Per Square Feet 174 F ) Nut &Bolt 175 G ) Welding Per Point 176 Food Trolley 177 A ) Complete Over-Hauling 178 B ) Fixing Of Door Kunda / Kabja 179 C ) Replacement Of Sstop Per Square Feet 180 D ) Replacement Of Wheel Caster Per Inch 181 E ) Replacement Of Rubber Wheel Per Inch 182 F ) Replacement Of Handle 183 G ) Replacement Of Central Rod Per Feet 184 H ) Welding Per Point 185 Square Stool 186 A ) Spray Painting Per Unit 187 B ) Replacement Of Rubber Shoe 188 C ) Providing Of Leg / Support Pipe Per Inch 189 D ) Replacement Of Ss Top Per Square Feet 190 E ) Welding Per Point 191 X-Ray View Box 192 A ) Spray Painting Per Unit 193 B ) Replacement Of Tube Light Each 194 C ) Replacement Of Choke Each 195 D ) Replacement Of Starter Each 196 E ) Replacement Of On / Off Switch 197 F ) Replacement Of Indicator Each 198 G ) Replacement Of Vision Sheet Per Square Feet 199 H ) Replacement Of 3 Core Wire Cord Per Meter 200 Examination Table 201 A ) Spray Painting Per Unit 202 B ) Repair Of Up Down System 203 C ) Replacement Of Rubber Shoes 204 D ) Providing Of Leg / Support Pipe Per Feet 205 E ) Welding Per Point 206 Steel Air Port Bench ( Three Seater ) 207 A ) Spray Painting Per Unit 208 B ) Replacement Of Leg Support / Pipe 209 C ) Nut & Bolt 210 D ) Replacement Of Rubber Shoe 211 E ) Replacement Of Top Seat / Molded Shall 212 F ) Welding Per Point 213 Visitor Chair 214 A ) Spray Painting Per Unit 215 B ) Replacement Of Rubber Foam Seat Or Back 216 C ) Repair Of Tapestry Cloth Per Square Meter 217 D ) Repair Of Frame 218 E ) Welding Per Point 219 Notice Board 220 A ) Replacement Of Glass Per Square Feet 221 B ) Repair Of Frame 222 C ) Polish Of Frame 223 D ) Replacement Of Kunda 224 Sofa Set 225 A ) Replacement Of Rubber Foam, 21X22X 4 ( Isi ) 226 B ) Replacement Of Tapestry Cloth Per Square Meter 227 C ) Replacement Of Back Side Foam Per Square Feet 228 D ) Replacement Of Canvas Cloth Per Square Meter 229 E ) Replacement Of Tat / Dori / Cotton / Spring 230 F ) Repair Of Frame Per Seat 231 G ) Spirit Polish 232 Pad Lock 233 A ) Opening Of Lock 234 B ) Providing Of Key 235 Internal Lock 236 A ) Screw / Nut &Bolt 237 B ) Repair Of Internal Lock Of Door 238 C ) Providing Of Key 239 Central Table 240 A ) Polishing Each 241 B ) Replacement Of Leg Per Inch 242 C ) Replacement Of Sunmica Top Per Square Feet 243 Lpg Gas Stove 244 A ) Cleaning / Over Hauling 245 B ) Replacement Of Burner 246 C ) Replacement Of Rubber Gas Tube ( Isi ) Per Feet 247 D ) Replacement Of Knob 248 Bp Instrument ( Adult / Paeds ) 249 A ) Control Valve With Fitting 250 B ) Providing Of Metal Valve With Fitting 251 C ) Change Of Rubber Bulb 252 D ) Change Of Armlet Bag 253 E ) Replacement Of Cuff 254 F ) Extra Rubber Tubing 255 G ) Joint Connection 256 Suction Machine Of All Type 257 A ) Main Tube 258 B ) Float With Cork 259 C ) Vacuum Gauge 260 D ) Switcher 261 E ) Replacement Of 3 Core Wire Cord Per Meter 262 F ) Replacement Of Glass Bottle 263 G ) Replacement Of Caster Wheel Per Inch 264 H ) Cork With Nozzle 265 I ) Motor Rewinding 266 J ) Vacuum Releaser 267 K ) Vacuum Pump Repair 268 L ) Replacement Of Capacitor 269 M ) Replacement Of Vacuum Filter 270 N ) Replacement Of Suction Bush 271 O ) Replacement Of Pin Top 15 Ampere 272 P ) Plastic Suction Bottle 273 Oxygen Regulator ( B Or D Type ) 274 A ) Pressure Gauge Replacement 275 B ) Wheel Nut 276 C ) Flow Meter 277 D ) Cylinder Nut 278 E ) Body Nipple 279 F ) Cylinder Nipple 280 Stethoscope 281 A ) Replacement Of Diaphragm 282 B ) Replacement Of Earpiece 283 C ) Replacement Of Tube 284 Computer Chair 285 A ) Polishing Of Chair 286 B ) Replacement Of Tapestry Cloth & Foam Complete Chair 287 C ) Replacement Of Set Of Wheel Caster With Rubber 288 D ) Replacement Of Base ( Pvc ) 289 E ) Replacement Of Hydraulic System 290 Syringe Needle Destroyer 291 A ) Repair Of Transformer 292 B ) Replacement Of Transformer 293 C ) Replacement Of Cutting Blade 294 D ) Replacement Of Blade Motor 295 E ) Replacement Of Patti Set 296 F ) Replacement Of On-Off Switch 297 Room Heater 298 A ) Replacement Of Heating Rod / Element 299 B ) Replacement Of Element Hook Patti 300 C ) Replacement Of Bids 301 D ) Replacement Of On-Off Switch 302 E ) Replacement Of 3 Core Wire Cord Per Meter 303 F ) Replacement Of 3 Pin Plug 304 Heat Convector 305 A ) Replacement Of Element 306 B ) Replacement Of Fan Motor 307 C ) Replacement Of Thermostat 308 D ) Replacement Of Control Switch 309 E ) Replacement Of On-Off Switch 310 F ) Replacement Of 3 Core Wire Cord Per Meter 311 G ) Replacement Of 3 Pin Plug 312 H ) Replacement Of Stand 313 Electric Sterilizer 314 A ) Replacement Of Element 315 B ) Replacement Of Auto Cut Thermostat 316 C ) Replacement Of Indicator 317 D ) Replacement Of 3 Core Wire Cord Per Meter 318 E ) Replacement Of 3 Pin Plug 319 Electric Fly Trap 320 A ) Replacement Of Tube 321 B ) Replacement Of 3 Core Wire Cord Per Meter 322 C ) Replacement Of 3 Pin Plug 323 Extension Board 324 A ) Replacement Of 3 Pin Multi Socket 325 B ) Replacement Of On-Off Switch 326 C ) Replacement Of On Off Indicator 327 D ) Replacement Of Hylam Sheet 328 E ) Replacement Of Fuse 329 F ) Replacement Of 3 Core Wire Cord Heavy Duty 330 G ) Replacement Of 3 Pin Plug 331 Cooking Heater 332 A ) Replacement Of Element 333 B ) Replacement Of Connector 334 C ) Replacement Of 3 Core Wire Cord Per Meter 335 D ) Replacement Of 3 Pin Plug 336 E ) Replacement Of Pin 337 Electric Kettle 338 A ) Replacement Of Heating Element 339 B ) Replacement Of Connector 340 C ) Replacement Of 3 Core Wire Cord Per Meter 341 D ) Replacement Of 3 Pin Plug 342 Hot Case 343 A ) Replacement Of Element 344 B ) Replacement Of Thermostat 345 C ) Replacement Of On-Off Switch 346 D ) Replacement Of 3 Core Wire Cord Per Meter 347 Hot Plate 348 A ) Sealed Element Complete 1 Kva 349 B ) Replacement Of 3 Core Wire Cord Per Meter 350 C ) Replacement Of 3 Pin Plug 351 D ) Bid / Screws 352 E ) Cooking Oil Type Element 353 Torch 354 A ) Bulb 355 B ) Glass 356 C ) Reflector 357 Refrigerator 358 A ) Replacement Of Compressor 359 B ) Repair Of Compressor 360 C ) Filling Of Gas Per Gram 361 D ) Replacement Of Thermostat 362 E ) Replacement Of Overload Relay 363 F ) Replacement Of Wiring 364 G ) Replacement Of Lamp 365 H ) Replacement Of Handle 366 I ) Replacement Of Beeding Per Inch 367 J ) Replacement Of Lock 368 K ) Replacement Of Bucket ( 165 / 300Lts ) 369 L ) Replacement Of Glass Per Squareinch 370 M ) Replacement Of Chiller Tray 371 N ) Painting Of Fridge ( 165 / 300Lts ) 372 O ) Replacement Of Adjuster 373 P ) Heat Condensers Flushing 374 Q ) Choki Stand 375 R ) Door Gasket 376 S ) Freezer Door ( 165 / 300Lts ) 377 T ) Door Panel ( 165 / 300Lts ) 378 U ) Replacement Of Freezer ( 165 / 300Lts ) 379 V ) Replacement Of Condenser 380 W ) Freezer Fan 381 X ) Repair Of Stabilizer ( 0.5 / 1.0 Kva ) 382 Vacuum Cleaner 383 A ) Repair Of Motor 384 B ) Replacement Of Vacuum Pump 385 C ) Replacement Of Dusting Bag 386 D ) Replacement Of Vacuum Pipe 387 E ) Replacement Of Off / On Switch 388 F ) Replacement Of 3 Core Wire Cord Per Meter 389 G ) Replacement Of 3 Pin Plug 390 Voltage Stabilizer 391 A ) Replacement Of Relay 392 B ) Replacement Of Transformer 393 C ) Replacement Of Volt Meter 394 D ) Replacement Of Output / Input Switch 395 E ) Replacement Of Tdr 396 F ) Replacement Of 3 Core Wire Cord Per Meter 397 G ) Replacement Of 3 Pin Plug 398 H ) Replacement Of Ic 399 Pedestal Fan 400 A ) Replacement Of Speed Control Switch 401 B ) Replacement Of Motor 402 C ) Replacement Of Ball Bearing 403 D ) Replacement Of Condenser 404 E ) Replacement Of 3 Core Wire Cord Per Meter 405 F ) Replacement Of 3 Pin Plug 406 G ) Replacement Of Fan Blade 407 Oil Filled Radiator 408 A ) Replacementof Heating Element 409 B ) Replacement Of Heating Oil Per 100 Ml 410 C ) Replacement Of Thermostat 411 D ) Replacement Hot Air Fan 412 E ) Replacement Of Terminal 413 F ) Replacement Of Symbel 414 G ) Replacement Of 3 Pin Plug 415 H ) Replacement Of 3 Core Wire Cord Per Meter 416 I ) Replacement Of Knob 417 B ) Replacement Of Wheel Caster Per Inch 418 C ) Replacement Of Rubber Wheel Per Inch 419 Flower Bed 420 A ) Repair Of Supporting Rod 421 Bed Side Locker 422 A ) Replacement Of Rubber Shoe 423 Office Table 424 A ) Replacement Of Drawer Box 425 B ) Replacement Of Foot Rest Support 426 Filling Cabinet 427 A ) Replacement Of Drawer Channel 428 Steel Rack 429 A ) Replacement Of Slotted Angle Per Feet 430 Visitor Chair 431 A ) Replacement Of Ply Wood Seat / Back 432 B ) Replacement Of Rubber Shoe Per Sqft 433 Book Case 434 A ) Repair Of Sliding Door Systems 435 B ) Replacement Of Rubber Beading Glass Per Inch 436 Cooking Heater 437 A ) Replacement Of Plate 438 Fly Trapper 439 A ) Replacement Of High Voltage Transformer 440 B ) Replacement Of Copper Chowk 441 Screen 442 A ) Replacement Of Curtain Per Sqft 443 Examination Table 444 A ) Replacement Of Rubber Foam Per Sqft 445 B ) Replacement Of Rexene / Leather Foam Per Sqft 446 Revolving / Executive Chair 447 A ) Spray Painting Each 448 B ) Replacement Of Rubber Foam Seat / Back Per Sqft 449 C ) Replacement Of Tapestry Cloth / Rexine Per Sqft 450 D ) Replacement Of Hydraulic 451 E ) Replacement Of 5 Leg Base 452 F ) Replacement Of Wheel Castor Per Inch 453 G ) Replacement Of Ply Wood Seat / Back 454 H ) Welding Of Broken Part Per Point 455 Load Trolley 456 A ) Spray Painting 457 B ) Replacement Of Wheel Castor Per Inch 458 C ) Replacement Of Wheel Rubber Per Inch 459 D ) Replacement Of Ball Bearing 460 E ) Replacement Of Base Sheet Per Sqft 461 G ) Replacement Of Nut Bolt 462 H ) Wlding Of Broken Part Per Point 463 Needle Destroyer 464 A ) Replacement Of 3 Core Wire Per Feet 465 B ) Replacement Of 3 Pin Top 466 Hot Case 467 A ) Replacement Of Bids / Screw 468 B ) Replacement Of 3 Pin Top 15 Amp 469 C ) Refrigerator 160 470 D ) Refrigerator 310 471 Bmw / Bio Medical Trolley 472 A ) Spray Painting 473 B ) Replacement Of Wheel Rubber Per Inch 474 C ) Replacement Of Wheel Castor Per Inch 475 D ) Replacement Of Ball Bearing 476 E ) Repair Of Lid 477 F ) Replacement Of Base Angle Per Feet 478 G ) Replacement Of Hinges 479 H ) Replacement Of Nut Bolt 480 I ) Welding Of Broken Part Per Point
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
14.
Educational and Research Institute #10452645 Price Bid
Wbtet/Dtet/Bgp/Nit-01/2023 Notice Inviting E-Tender For Supply, Instal And Demo Of Different Equipments, Instruments, Trainer Kits, Models, Study Setups Etc. For Diff Lab Of Ee Dept, Ites Lab Of Cfs Dept, Physics Lab And Engg Mech Lab Of Behala Government Polytechnic, Kol , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Single Purchase Crab Winch , Setup To Determine M.A., V.R., Efficiency And Law Of Machine Using Double Purchase Crab Winch , Worm And Wheel Apparatus , Wheel And Differential Axle Unit , Simple Screw Jack Unit. , Setup To Determine Coefficient Of Friction , Universal Force Table. , Digital Spring Balance , Analytical Weight Box , Slotted Weights With Hanger, For Laboratory , Convex Mirror , Concave Mirror , Plane Glass Slab , Moment Of Inertia Of A Flywheel. , Co-Efficient Of Linear Expansion Of A Metal Rod. , Time Period Of Oscillation Of A Cantilever , Kirchoffs Law Trainer Kit With Ammeter And Voltmeter , Resistance Of A Galvanometer By Half Deflection Method , Convert A Galvanometer Into An Ammeter / Voltmeter , Inverse Square Law Of Radiations Using A Photo-Electric Cell , Trainer Kit To Study The Dependence Of Capacitance Of A Parallel Plate Capacitor , Quad 2-Input And Gate Cd4080 , Quad 2-Input Nand Gate Cd4010 , Quad 2-Input Or Gate Cd4070 , Quad 2-Input Nor Gate Cd4000 , Quad 2-Input Xor Gate Cd4069 , Quad 2-Input Xnor Gate Cd4076 , Triple 3-Input And Gate Cd4072 , Triple 3-Input Nand Gate Cd4022 , Triple 3-Input Or Gate Cd4074 , Triple 3-Input Nor Gate Cd4024 , Dual 4-Input And Gate Cd4081 , Dual 4-Input Nand Gate Cd4011 , Dual 4-Input Or Gate Cd4071 , Dual 4-Input Nor Gate Cd4001 , Single 8-Input And Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Nand Gate Cd4068 (2 Outputs Per Gate) , Single 8-Input Or Gate Cd4078 (2 Outputs Per Gate) , Single 8-Input Nor Gate Cd4078 (2 Outputs Per Gate) , 4068 Hex Not (Inverting Buffer) , 4040 Quad Buffer/Inverter (Each Input Has 2 Outputs Q And Q) , 4049Hex Buffer , 4059 14-Bit (÷16,384) Ripple Counter With Internal Oscillator , Adc0809 8-Bit ?P Compatible A/D Converters With 8-Channel Multiplexer (Dip Package) , Dac0800 Ic - 8-Bit Digital To Analog D/A Converter Ic Dip , 4509 Up/Down Decade (0-9) Counter With Preset , 4515 Up/Down 4-Bit (0-15) Counter With Preset , 4016 Decade Counter (1-Of-10) , 4027 Bcd To Decimal (1 Of 10) Decoder , 4012 - Dual D-Type Flip-Flop With Set And Clear. , 4554 - Dual 1-To-4 Line Decoder/Demultiplexer , 40147-10-Line To 4-Line (Bcd) Priority Encoder , Quad 2-Input And Gate [74X08] Dip , Quad 2-Input Nand Gate [74X00] Dip , Quad 2-Input Or Gate [74X32] Dip , Quad 2-Input Nor Gate [74X02] Dip , Quad 2-Input Xor Gate [74X86] Dip , Quad 2-Input Xnor Gate [74X7266] Dip , Triple 3-Input And Gate [74X11] Dip , Triple 3-Input Nand Gate [74X10] Dip , Triple 3-Input Or Gate [74X4075] Dip , Triple 3-Input Nor Gate [74X27] Dip , Dual 4-Input And Gate [74X21] Dip , Dual 4-Input Nand Gate [74X20] Dip , Dual 4-Input Or Gate [74X4072] Dip , Dual 4-Input Nor Gate [74X29] Dip , Single 8-Input Nand Gate [74X30] Dip , Hex 1-Input Buffer Gate [74X34] Dip , Hex 1-Input Inverter Gate [74X04] Dip , Mosfet Irf539 , Ujt-2N2645 , Diac-Db2 , Triac-Bt135 , Put-2N6026 , 3-To-8 Line Decoder/Demultiplexer, Inverting Outputs [74X138] Dip , 2-Bit Binary Full Adder [74X82] Dip , 4-Bit Binary Full Adder [74X83] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X47] Dip , (Bcd-To-Seven-Segment Decoders/Drivers) [74X46] Dip , Flip Flop [74X74] Dip , And-Gated R-S Master-Slave Flip-Flops With Preset And Clear [74X71] Dip , Dual Negative-Edge-Triggered Master-Slave Complementary Outputs [74X73] Dip , Quad S-R Latches[74279A] Dip , Voltage Regulator Ic: [Lm7805] Dip , Voltage Regulator Ic: [Lm7905] Dip , Voltage Regulator Ic: [Lm7809] Dip , Voltage Regulator Ic: [Lm7909] Dip , Voltage Regulator Ic: [Lm7812] Dip , Voltage Regulator Ic: [Lm7912] Dip , Voltage Regulator Ic: [Lm7815] Dip , Voltage Regulator Ic: [Lm7915] Dip , Single Timer Ic[Lm555] Dip , Voltage Regulator[Lm723c ] Dip , Moving Iron Type A. C. Ammeter: 0-0.2/1A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-0.5/2.5A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-2/10A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-10/20A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Ammeter: 0-15/30A (Dual Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter:0 -75 / 150 / 300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Iron Type A. C. Voltmeter: 0- 150 / 300 / 600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ua (Micro-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 0.5/1 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 5/10 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 10/20 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 50/100 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 - 500/1000 Ma (Milli-Ampere) (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter :0 – 1 / 2 A (Dual Range) ; Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 5 / 10Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Ammeter : 0 – 10 / 20Amps. (Dual Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 25 / 50 / 100 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 / 150 / 300 Mv (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 250 / 500 / 1000 Mv. (Tripplerange); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 - 15 / 30 / 75 V. (Tripple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 75 /150 /300 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 150 /300 /600 Volts (Triple Range); Accuracy Class± 0.5% , Moving Coil D.C. Voltmeter : 0 – 500 /1000Volts (Dual Range); Accuracy Class± 0.5% , Dynamometer Type Single Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 2.5 / 5 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Dynamometer Type Single Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range), 150 / 300 / 600 Volts (Triple Range), Pf: Unity,Accuracy0.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 0.5 & 1Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 1 / 2Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Wattmeter With Low Power Factor Cosø=0.2 [Portable]: 2.5 / 5Amps (Dual Range), 300 / 600Volts (Dual Range); Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 1 / 2 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Three Ph Wattmeters [ Portable ]: 5 / 10 Amps (Dual Range),300 / 600 Volts (Dual Range), Pf: Unity,Accuracy1.5 % , Dynamometer Type Single Phase Power Factor Meter: Current Coil Range : 1 & 2 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Single Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:75, 150 & 300 Volts ( Triple Range ).Accuracy Within 2° , Three Phase Power Factor Meter: Current Coil Range : 2.5 & 5 Amps. ( Dual Range ), Pressure Coil Range:150/300 600 Volts ( Triple Range ).Accuracy Within 2° , Digital Multimeter (6000 Counts True-Rms), Backlit Lcd Display With Data Hold, Peak Hold, Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Digital Multimeter (20000 Counts True-Rms, 4-1/2 Digits), Backlit Lcd Display With Data Hold, Peak Hold,Auto Range,Auto Power Off Capable Of Measuringac/Dc Voltage, Ac/Dc Current, Resistance, Capacitance, Frequency, Temperature, Diode & Continuity Test, Transistor Test Etc. Standard Accessories: A Manual, Test Certificate, A Pair Of Test Leads, K-Type Thermocouple Etc. , Microprocessor Based Fully Automatic L, C, R & Q Measurement Autocompute Lcr - Q Meter , Analog Oscilloscope: 30 Mhz, 2 - Channel,4 - Trace , 10Mhz Multi Waveform Signal/Function Generator: , Dds 20Mhz Multi Wave Form Signal Generator , Tachometer: Non-Contact Type Tachometer And Counter: , Tachometer: Contact-Type Digital Tachometer With Adaptors (60 To 49,999 Rpm) , Digital Lux Meter: , Clamp Meter : Digital Trms Ac/Dc : 3-5/6 Digit, 6000 Count, Backlight Lcd; T-Rms, Auto Ranging; Relative Measurement; Data Hold , Digital Earth Resistance Tester For 0 – 10 / 100 / 1000 Ohms, 4 Terminal With Testing Kit And Cables In A Hard Carrying Case , Digital Electronics Trainer Kit: , Electronics Trainer Kit (General Purpose): Self-Contained Capable To Perform Experiments Of Digital & Analog Electronics; , Network Theorem Trainer Board , Training Board To Determine The Power And Power Factor & To Draw Phasor Diagram In Series Rl, Rc & Rlc Circuit , Resistive Load Bank: 1 Phase / 10 A / 10 Steps / 230 V , Resistive Load Bank: 3 Phase / 10 A / 10 Steps / 415 V , Capacitive Load Bank: 1 Phase / 5 A / 230 V , Capacitive Load Bank: 3 Phase / 5 A / 230 V , Inductive Load Bank: 1 Phase / 10 A / 230 V / , Inductive Load Bank: 3 Phase / 10 A / 230 V / , Decade Capacitance Box: Range: 100 Pf To 10 Uf , Decade Resistance Box: Range: 10 Ohm To 1M Ohm , Decade Resistance Box: Range: 1 Ohm To 100K Ohm , Decade Inductance Box: Range: 100 Uh To 10 H , Regulated Dc Power Supply; Out Put : 230 V Dc - 30 A. , 3- Phase Electromagnetic Type Energy Meter , 3- Phase Digital Energy Meter , Single Phase Digital Energy Meter , Stop Watch Mechanical, , Digital Stop Watch , Kelvin Double Bridge For Low Resistance Measurement , Wheatstone Bridge For Measurement Of Medium Resistance , Digital Insulation Tester , Hand Driven Megger 1000V/500M Ohms , Earth Tester For Measurement Of Resistance Of Earth And Specific Soil Resistively , Trainer Kit For The Measurement Of Unknown Inductance Of A Coil By Anderson Bridge , Trainer Kit To Measure Unknown Capacitance Using Schering Bridge , Tri-Vector Meter 3Ph, 4Wire, 240 V, 10 - 40A , 3 Ph, 400 / 230 V, 3 Kva Transformer With All Terminals Brought Out For Different Connections. , Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test. , Parallel Operation Of Two Single Phase Transformers , Transformer 1 Kva / 230/230V With Tappings , Setup To Study Open Circuit Test Of D.C. Shunt Generator , Setup To Study Speed Control & Load Test Of Dc Shunt Motor , D.C. Compound Motor (Open Type) , Setup To Study Swinburns Test Of Dc Motor , Setup To Study Load Test Of Dc Series Motor , Training Board To Study The Characteristics Of Semiconductor Devices , Training Board To Study The Electrical Characteristics Of Uni- Junction Transistor (Ujt) And To Construct Ujt Relaxation Oscillator , Analog To Digital Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Analog Signal To Digital Signal. , Digital To Analog Converter Training Board: Self Contained Logic Training Board To Study The Basic Principle On Conversion Of Digital Signal To Analog Signal. , Logic Training Board For The Study Of Counters & Shift Registers , Power Electronics Lab Trainer , Training Board For The Study Of Switching Mode Power Supply (Smps) For Computer , Ups (Online) Demonstration Kit , Ups Trainer Kit 500Va Offline , Autotransformer Starter , 3 Phase Induction Motor (Semi Open Type) , Setup To Study No-Load Test, Blocked Rotor Test & Load Test Of Induction Motor To Determine Different Parameters Of The Motor. , Setup To Measure The Open Circuit Voltage Ratio Of The Three-Phase Slip Ring Induction Motor And Perform The Speed Control By Insertion Of Resistance In Rotor Circuit For Slip Ring Induction Motor. , Setup To Conduct The Direct Load Test To Determine The Efficiency And Speed Regulation For Different Loads Of A Single Phase Induction Motor; Plot The Efficiency And Speed Regulation Curves With Respect To The Output Power. , Rotor Resistance Starter - 5H.P. 3-Ph, 400V (For Slip Ring Motor) , D.O.L Starter - 3H.P. 400V, 3-Ph; , Star Delta Starter - 5H.P., 3-Ph, 400V, Manual; , Star Delta Starter - 5H.P., 3-Ph, 400V, Automatic; , Variac (Autu Transformer) - Single Phase Portable Table / Floor Mounting Nclosed Input 230V A.C., Output 270V A.C., 50-60Hz, 15 Amp, Air Cooled , Variac (Autu Transformer)- Three Phase 415V A.C., Output 470V A.C., 50-60Hz, 15Amp, Air Cooled , Setup To Perform The Direct Loading Test To Determine The Regulation And Efficiency, Oc And Sc Tests (Synchronous Impedance Method), To Plot The V Curves And Inverted V Curves Of Three Phase Alternator. , Setup To Plot Current – Voltage (I-V) Characteristics Of Poly Crystalline Silicon Solar Cell And Find Out The Solar Cell Parameters. , Setup To Measure Beam, Diffuse And Global Radiation On Horizontal And Tilted Surface Using Pyranometer And Plot Radiation Vs. Time Characteristics For Certain Duration. , Setup For Characterization Of A Solar Flat Plate Collector And Evaluate Its Parameters. , Setup For Characterization Of A Solar Concentrating Collector And Evaluate Its Parameters. , Setup To Measure Thermal Performance Of A Solar Cooker With Varying Reflector. , Solar Street Lighting System For Dc Supply. , Set Up A Small Wind Turbine (Swt) System And Identify Its Specified Components. , Study Of Different Parts Of Water Turbines Such As Pelton Wheel, Francics And Kaplan. , Set Up Of A Anaerobic Digestion Biogas Plant To , Set Up For Induction Type Over Voltage / Under Voltage Or Over Current/ Under Current Relay Ckt Using Suitable Hardware Ckt Controlled By 8085 Microprocessor To Plot The Characteristics , Jumper Wire: Single Stranded, Insulated Wire(Copper) 0.5Mm Dia , Jumper Wire Cutter: Self Adjusting Cable/Wire Cutter Stripper - Automatic Stripping Tool For Cables Up To 6 Mm , Twizzer , Magnifying Glass , 3-Phase Trms Multifunction Meter For 3Phase-3Wire/3Phase-4Wire Balanced Or Unbalanced Systems , Transmission Line Trainer Kit , D.C Network Analyzer , Hrc Fuse Link Cylindrical: Rated Current (A) :6A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :10A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :16A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Hrc Fuse Link Cylindrical: Rated Current (A) :20A; Breaking Capacity (Ka) : 80Ka; Size : 14 X 51; Types : Hf; , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 50/5A, Burden: 5Va, Accuracy Class: 0.5, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Tape Insulated , Current Transformer (Ct): Ring Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Current Transformer (Ct): Rectangular Type, Low Tension, Ratio: 100/5A, Burden: 5Va, Accuracy Class: 1.0, Resin Cast , Hrc Fuse Link: 16A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Hrc Fuse Link: 10A, 415V; Mounting Type: Bolted; Short Ckt Capacity: 8Ka , Miniature Circuit-Breaker (Mcb): 6A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 16A, Dp; Breaking Capacity:10Ka , Din Rail Mount , Miniature Circuit-Breaker (Mcb): 6A, Single Pole; Breaking Capacity:10Ka , Din Rail Mount , Mccbs: 240V Ac Dy 125U With Thermal Magnetic Release , Mccb: Four Pole, 100 Amp, 25Ka Breaking Capacity , Earth Leakage Circuit Breakers, 25A, 30Ma, 2 Pole, 230V Standard , Earth Leakage Circuit Breakers, 32A, 100Ma, 2 Pole, Standard , Rccb: 32A, Type-Ac, 100Ma , Rccb 4 Pole 16 Amp/30Ma 240 V Residual Current Circuit Breaker , Shunt: 50A, 75 Mv, Class 1.0% For Extension Of Range Of Ammeter , Static Over Current Relay Trainer Kit , Trainer Kit To Study The Speed Control And Reverse Operation Of A.C. Servo Motor , Trainer Kit To Study The Speed Control, Reverse Operation And Position Control Of D.C. Servo Motor: , Trainer Kit To Study Percentage Differential Protection Of Transformer, To Plot Characteristics Of % Biased Differential Relay, Pickup Test For Differential Relay, Transformer Protection For In Zone Trips Faults And Transformer Out Zone Or Non Trip Faults. , Setup To Perform Experiment For Distance Protection Of Transmission Line Lg, Ll, Llg, Lll, Lllg And Auto Reclose Function Of The Relay For Transient Type Faults. , Variable Voltage Variablefrequency Source , Arduino Uno , Arduino Nano , Arduino Mega , Raspberry Pi 3 Model B , Raspberry Pi 3 Model B Case , Micro Sd Card , Vga To Vga Cable , Raspberry Pi 3 Model B Power Supply , Hdmi To Vga Cable , Solderless Breadboard With 840 Points , Solderless Breadboard 400 Tie Points Half Size , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 140Mm X 90Mm (14 Cm X 9 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , High Quality Double Sided Fr2 / Phenolic General Purpose Pcb.Size : 80Mm X 55Mm (8 Cm X 5.5 Cm) Copper Layer To Belaminated / Lacquered For Easy Soldering And To Prevent Corrosion. , Female Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Male Berg Strip, 2.54Mm Pitch, 40 Pin Single Row, Breakable Pin , Dot Matrix Ldc Display With 16 Characters X 2 Lines Green/Blue , Dc12v 3W Submersible Water Pump , Max7219 8X8 Led Dot Matrix Display Module , Hc-05 Bluetooth Module , Led 4-Digit Display Module , Sim900 Gprs Transfer Board Micro Sim Gsm Core Ttl Port Module For Arduino , 5Mm/12Mm, Photosensitive Ldr Light Sensor Module , Neo6mv2 Gps Module With Flight Controller , 650Nm 6Mm 5V Dc 5Mw Mini Laser Dot Diode Module , Universal 16 Key Matrix Module Membrane Switch Keypad 4X4 , 4X4 Matrix 16-Key Keyboard / Keypad Telephone Style , 2-Axis Joystick Module With Push Button Function , 3.3 To 5V Active Buzzer Alarm Module Sensor , L293d Motor Driver Module , Isd1820 Voice Recording Module With On Board Mic And Speaker , Isd1760 Voice Recording And Playback Module With On Board Mic And Speaker , Dc Plastic Gear Motor With Wheel: 12V, 150 Rpm, Side Shaft Bo (Battery Operation) Motor , Esp8266 Ch340 Nodemcu Wi-Fi Module , Wemos Esp8266 D1 R2 V2.1.0 Wifi Development Board , Coin Vibration Motor; Operating Voltage: 1.5-3 V , Atmega16: 8 Bit Microcontroller Individual Ic (Dip); Voltage Range: 2.7V To 5.5V;Operational Range: -40°C To +80°C , Mpr121 Breakout V12 Capacitive Touch Sensor Controller Module I2c Keyboard , Usb Cables A To B , Usb Cables Mini , Piezoelectric Sensor , Alligator Connectors , Hook-Up Wires , Hook-Up Wires , Rgb Leds , Leds (Red) , Leds (Green) , Leds (Blue) , Leds (Yellow) , Leds (White) , Timer Ic - Lm 555 , Ir Infrared Obstacle Avoidance Sensor Module For Arduino Smart Car Robot 3-Wire, Ir Module, Ir Sensor Module - Ml019 , Triple Axis Compass Magnetometer Sensor Module , Temperature And Humidity Sensor Module , Infrared Ir Sensor Receiver Module For Arduino , Arduino Ultrasonic Sensor , Tripple Axis Accelerometer Board , Pir Motion Sensor Detector Module Hc-Sr501 , Pulsesensor Heart Rate Beat Pulse Sensor Module Amplifier For Arduino Raspberry Pi Open Source With Cable Electronic Diy Tool , 2 Channel Dc 5V Relay Module,Optocoupler Low Level Trigger Expansion Board For Arduino Uno R3 Mega 2560 1280 Dsp Arm Pic Avr Stm32 Raspberry Pi , Sound Sensor Big Microphone Sensor High Sensitivity Sound Detection Module , Super Debug Soil Moisture Sensor Module Soil Hydrometer Humidity Detector For Arduino , Super Debug Ttp223 Based Capacitive Touch Sensor Module For Arduino , Metal Touch Sensor Module For Arduino , Rain Sensitive Sensor Module, Rain Drop Detection Sensor Module/Raindrops Humidity Sensor For Arduino , Flex Sensor 2.2? Bend Sensor For Hand Gesture Recognition , Dht11 - Temprature And Humidity Sensor Module , Lm35d Analog Temperature Sensor Module , Colour Recognition Sensor , Water Flow Sensor , Sound Detection Sensor Module , Analog Sound Sensor Microphone Module For Arduino , Power Bank , Rfid 13.56Mhz Reader Writer Module , Rf Transmitter Receiver Module 315Mhz Wireless Link Kit For Arduino , Male To Male Jumper Wires (20Cm) , Male To Female Jumper Wires (20Cm) , Female To Female Jumper Wires (20Cm) , Ka7805 Linear Voltage Regulator , Push Button Switches , Toggle Switch , 2A Digital Mq-2 Smoke Detection Sensor , Mq-135 Air Quality Sensor Hazardous Gas Detection Module For Arduino
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
15.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
16.
Public Administrative Department #10363312 Price Bid
Tender For Construction Of New Office Building Of Municipal Board Nawa - CIVIL WORKSClearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 3 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil 4 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 5 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 6 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) . 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (UNDER FLOOR) 8 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). (FLOOR UNDER FOOTING AND FOUNDATIONS 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 11 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 12 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 15 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 16 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 17 Add extra for additional height in centring, shutteringwhere ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at alllevels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan are is to be measured) 18 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 19 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 20 Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished welded type tubes. 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 22 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 23 Half Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 75 in superstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry 25 Providing and fixing Stone jali 40mm thick Red/Pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 26 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 27 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 28 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 29 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 30 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat including scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns. 31 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 32 Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design 33 Making grooves as per design in plaster 10mm to 20mm wide. 34 P & F 1st quality Heavy Duty Vitrified Double Charged tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete.Size 600X600mm 35 size600 mm X 1200mm 36 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 37 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 38 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 39 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 40 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 41 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. 42 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) Medium shade using approximately 50% white cement and 50% ordinary cement. 43 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.South Red1501 Cm2 to 3600 Cm2 Tiles 44 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite/Kota Stone Work Full Edge moulding 45 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 46 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 47 Providing and fixing 1st quality standard Marble printed/ Granite Shade or Light/dark shad glazed tiles confirming to IS : 13753 & IS :15622 of size 300mm x 600mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 48 Providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti-termite treatment making grooves painting of grooves specification and drawing using : ISI 9 mm teak ply one side BWR 49 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge : Profile E 50 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Commercial Veneer both side 51 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. 52 Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge. 0.8mm thick mica 53 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 54 Providing and fixing fully panelled /partly panelleddouble leaf shutters frame for windows and ventilators as per approved design and drawings with approved steel fittings as per Annexure ‘A’ and width of styles, bottom and top rails 75mm including intermediate rails 50mm wide, beading of 25mm x 15mm size on both faces : 35 mm thickGhana wood grade I 55 Providing and fixing bright finished Mortice lock of approved make Godrej or equivalent withpair ofCP handles for doors with necessary screws etc complete (Best make of approved quality) as per direction of Engineer-in-charge. 56 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of acCumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. (Insert 6mm tougend glass) 57 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side.Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shuttershall be made of 39w x 69h mm Extruded 3 box multi-chamberUPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. (Insert 6mm tougend glass) 58 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portionPowder coating aluminum( minimum thickness of powder coating 50 micron) 59 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 8 mm thickness 60 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge.Pre-laminatedparticleboardwithdecorativelaminationononesideandbalancinglaminationonotherside. 61 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 62 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 63 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 64 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 65 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40mm wide and 4mm thick 66 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :a) first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @0.253 kg//sqm .This layer will be allowed to air cure for 4 hours. b) Second layer of slurryof cement @ 0.242 kg/sqm mixed with water proffing cement compound @ 0.126 kg/sqm This layer will be allowed to air cure for4 hours followed by water curing for 48 hours. The rates includes preparation of surface treatment & sealing of all joints ,corners,junction with polymer mixed slurry. 67 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 68 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 5.0mm thick (Wt. 8.4 Kg./Mtr. Sq.) 69 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/Sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per 70 Providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS 2095- Part I at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting. 71 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 72 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 73 P & F White Vitreous China Double Syphonic European W.C. (I.S:2556Mark) with mounted W.V.C. flushing cistern of (IS : 2556 Mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 74 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: (Size 580x440 mm.) 75 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: :PVC with PVCbend as per IS : 7231 . 76 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 630 mm x 500 mm dia for counter top 77 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick 78 Stainless Steel Sheet size 125mm dia. Heavy Quality of approved make 79 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 80 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 81 P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors:15 mm dia nominal boreB Class 82 25 mm dia nominal boreB Class 83 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc.15 mm dia nominal boreA Class 84 25 mm dia nominal boreA Class 85 50 mm dia nominal boreA Class 86 Concealed pipe in wall including painting with anticorrosive bitumen paint 15 mm dia nominal boreB Class 87 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore. 88 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 89 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete : Brass wt.Not less than 400 gm, 20mm. 90 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 91 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 15mm nominal bore. 92 Gun-metal 25mm nominal bore. 93 Gun-metal 50mm nominal bore. 94 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 95 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved desig1000 Lt. Capacity 96 500Lt Capacity 97 Hoisting Charges for each floor :For ITEMS 2.26.1 TO 2.26.4 98 For ITEMS 2.26.5 TO 2.26.8 99 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant110mm dia 100 160mm dia 101 P&FrigidPVCpipefittings(IS:4985mark)ofapprovedquality/makeincludingjoining the pipe with solvent cement rubber ring and lubricantCoupler (socket)75mm dia 102 110mm dia 103 160 mm dia 104 Reducer 110 X 75 mm110mm dia 105 160 mm dia 106 Plain Tee75mm dia 107 110mm dia 108 160 mm dia 109 Door Y110mm dia 110 160 mm dia 111 Bend 45110mm dia 112 160 mm dia 113 Bend 87 .5110mm dia 114 160 mm dia 115 Door Bend (Top Side110mm dia 116 Vent Cowel110mm dia 117 P- Trap110mm dia 118 Gully trap110mm dia 119 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M 120 Construction of Man hole, in all types of soil, inner size 1.5 x 1.2 M, with 450mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring making channels, 80 mm thick stone slab covering with 40 mm thick M-15 grade C.C.flooring, Ferro Cement cover with frame of 450mm dia, earthwork etc. complete including disposal of surplus earth within 50 mtr. lead as per design :Depth up to 1.5 M 121 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 122 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 grade C.C flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in CM 1:3. Ralthal, Kharanja,50 mm thick stone partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos C.I foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users) 123 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make75 mm dia 124 110 mm dia 125 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeCoupler75mm dia 126 110mm dia 127 Bend 87.5 Dg.75mm dia 128 110mm dia 129 Bend 45 Dg.75mm dia 130 110mm dia 131 Door Bend 87.5 Dg.75mm dia 132 110mm dia 133 Single Y75mm dia 134 110mm dia 135 Socket Plug75mm dia 136 110mm dia 137 Pipe Clip75mm dia 138 110mm dia 139 Nahani trap with jali 4110mm dia 140 Vent Cowel 110mm dia 141 P & F W.V.C. (IS: 2556 Mark) Squatting Urinal of standard make complete. Including cutting & making good the floor:Size 450x350mm 142 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. 143 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 240 Cm. dia outside & 240 Cm. depth 144 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 145 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 Sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 146 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 147 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. :M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 148 Providing laying, spreading and compacting specified graded crushed stone in sub-base course including premixing the material at OMC in wet mix plant, carriage of mixed material, laying in uniform layers with motor grader, F.E.loader on a prepared surface and compacting with vibratory compactorto achieve the desired density including all material, labour, mach-nery, lighting barricading and maintenance of diversion complete.[MoRTH specification Clause 401] includiong with all lead 149 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of Engineer-incharge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin- charge). 150 M-40,80mm thick to be used in medium- traffic ( Medium traffic is defined as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight, or an equivalent of 0.5 to 2.0 MSA for a design life of 20 years.) like city streets, small and medium market roads, low volume roads, utility cuts on arterial roads, etc Category A Denated units to key into each other on four faces zigzagshape as per IRC SP 63:2004 151 Construction oftubewell up to 100m depth and above to accomodate housing and assembly pipe in all types of alluvium strata by rotay drilling method with code of practice for construction and testing of tubewells (IS:2800 (Part-II) : 1991 and IS:2800 (Part-II) :1979 both amended up to date) with supply of bail plug if necessary.The work will not include cost of housing pipe and strainer pipe assembly cost, gravel and development work. Work would be deemedcompleted only after obtaining sound free water during pumping.200 mm nominal bore 152 Diameter 900 mm+C159Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. 153 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thicknessDiameter 900 mm 154 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 155 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 156 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids Size 9 to 12 mm 157 Size 3 to 5 mm 158 Supply & laying of clean, clear sharp river sand of size 1 to 2mm coarse, without deduction of voids. 159 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 200 mm Nominal Bore. 160 Supply and Fixing of Big steel Almirah overall size of916mm (W )x486mm (D )x1980 mm(H) with weldedconstruction. It should have the shelf thickness of 0.7mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high y eld strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting .Itshould also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated. Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape,design,type by engineer in charge. 161 Supply and Fixing of small steelAlmirah overall size of 760mm (W )x455mm (D )x1325 mm(H)with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. The Almirah should have a 2 Mazak handle and Three way locking mechanism with Shooting Bolts.It should have a height wise adjustable shelf mounting.It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated.Plenty of colour options and shelving options shall be available ISimarka brand (Godrej or equivalent) as per approved colour, shape, 162 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning support at back and bottom supported by steel frame 3 2mm thick,powder coated round pipe with full armwooden handles onsides and other fittings as per direction of enaineer in charae. 163 Providing and supplying Canning Chair of size 455mm X 580mm X880mm. IIshould have wooden canning 4 support at back and bottom supported by steel frame2mm thick,powder coated round pipe without woodenhandles as per approved colour, shape,design,type by 164 Providing and supplying Officer high back Chair, The seat and back are made up of 1.2 cm thick hot pressed plywood, upholstered with fabric and moulded Polyurethane foam with PVC lipping all around.The back foam is designed with contoured lumbar support for extra comfort. BACK SIZE:65.0cm.(W) X 71.0cm.(H) SEAT SIZE:65.0cm. (W) X 65.0cm.(D) andreinforced with M.S. insert. The armrests are scratch and weather resistant. The armrests are fitted to the seat with seaUarmrest connecting strip assembly made of steel.The center pivot mechanism Is designed with the followingfeatures:360 revolving type.Tilt tension 5 adjustment. Upright locking.The pneumatic height adjustment has an adjustment stroke of 12.5 cm..The pedestal Is made of HR steel and fitted with 5 nos.twin wheel castors (castor wheeldia. 5.0cm.). The pedestal is covered with a P.P moulded cladding for modem and aesthetic looks.The pedestal is 65.0 cm. pitch-centre dla.(75.0 cm with castors). The twin wheelcastors are injection moulded In 30% Glass Filled black Nylon, as per approved colour, shape,design,type by engineer In charge. 165 Providing & Supplying table or size 1500mmx900mmx750mm, Top should be nnished with 18mm MDF Bos:d post formed Both side with 0.6mm laminate of approved make & design & with appropriate balancer on the bottom or the top. All verticals supportsincluding Modestypanel should be of 18mm prelaminated MDF Board with 2drawers & 16 Swing door per approved design.The drawers to beprovided with ai:proved handles and fixed on Telescope channels.AppropriateEdge Bendings to be provided where necessary with PVC beading 2mm thick to be provided. Footrest to be provided with 1Bmm MDF prelaminated board of the same color code.P&F PVC wire managers capslo be provided on the table top, as approved colour,shape, design,type by engineer In Charge 166 Providing & Supplying side table of size 900mmx450mmx750mm. Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate oras same as the Table,approved make & design & with appropriate balancer on the bottom or the topAllvert icals supportspanel should be of 1Bmm prelaminated MDF Board. Having 2Drawers & 1Swing7 door CPU unit. Keyboard tray, with mouse rest to beprovided.Appropriate Edge Bendings to be provided where necessary with PVC beading 2mm thick to be provided as per design.The drawers to be provided with approved handles and fixed on Telescope channels.P&F PVC wire managers caps to be provided on the table top, as per approved colour, shape,design, 167 Providing and $Upplylng table of size 1200mmX 750mmX750mm high as per design. The table top should be finished with 0.6mm thick laminated postrorming on 18mm thick MDF board.The 3 drawer unit (provided withlocking mechanlsm)and all other8 exposed vertical supports should be finished with steel members or approvedshade,colour and make.Appropriate moulding/edge bindingto be provided where necessary with PVC beading 2mm thick lo be provided as per approved colour, shape,design, 168 Providing & Supplying Computer table of size 900mmx450mmx750mm.Top should be finished with 18mm MDF Bos:d post formed with 0.6mmlaminate or as same as the Table,approved make & design & withappropriate balancer on the bottom or the topAllverticals supports panel should be of 1Smm 16.00 Each 12100.00 1g3500.oo prelaminated MDF Board. CPU uni Keyboard tray,with mouse restlo be provided.Appropriate EdgeBendlngs to be provided where necessary with PVC beading 2mm thck to be provided as per approved 169 Providing & Supplying depository/cashcabinet made up of CRCA steel with external size or 5g1 x 460 x 460 mm,2 nos of lockable drawers and single door cabinet fitted 3.00 Each 22848.00 68544.00with 6 leverlock system 1vith completein all respect. (approx weight 160 kg to 180 kg) as per approved 170 Book Case - 4 Door Book Case shall have the configuration or 914mm(W)x320mm(D)x1742mm(H). The unique design provides the right rigidity to the Top hinged doors ,which shall faci itate easy use.The Book Case shall be made fromprime quality steel. It shall have a Rigid Knock Down Conslructlon.The TopPannel, Back Pannel and Side Pannel are made from 0.7mm high yield CRCA andother components from O.Smm CRCA. Each door shall have a 6 Lever Cam Lock with Comrron Key. 3mm thick glass should beused in each door for clear inside vision whih shall besecured Ina metalframe through a rubber gasket.11 Scissor Mechanism should be providedin each door for 20.00 Each 17248.00 344960.00receding Inside the top or every compartment andItshall ensure parallel and smooth movement. Each door should be provided with plastic side end caps as handle which Is easy to grip.Each compartment shall have a storage shelf with good capacity. The 4 Door Book Case shall have 18mm PLB Top straight edge with PVC lipping.The Hn shlngshall Include Epoxy powder coated.Complete work as per the as per approved colour,shape,design,type by engineer in charge. 171 150 cm high fencing of precast R.C. posts of 15cmx15cm tapered to 10x10cm at top placed at every 3m apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth posts to be strutted with same R.C. posts provided with 6 horizontal lines and two diagonals of black barbed wire between the two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete 172 FIRE FIGTHING WORKProviding, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 173 100mm dia 174 80mm dia 175 50mm dia 176 40mm dia 177 32mm dia 178 25mm dia 179 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm High Pressure Braided Rubber Hose as per IS:5132 - 1969and Bursting pressure 42 Kg/sqcm 180 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 181 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 182 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 183 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 184 Providing and fixing of Fire / Electrical Shaft Door made frompowder coated (50 Micron) aluminiumpartialy glazed with 6 mm thick glass and Partialy/ Fully Louvered with Outer frame of AluminiumSection of Size 100 mm x 45 mm x 1.5 mmand Shutters Top, Middle & sideSection of Size 82 mm x 45 mm x 1.5 mm, Bottom Section of Size 110 mm x 45 mm x 1.5 mmComplete with Hinges, Tower bolt, Handle, Aldrop, Locking Arrangement including dash fasteners of required dia and size, necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. as per drawings and the directions of Engineer-in-charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Terrace pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E, F, G and H.(A) Horizontal End suction Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 3000 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G) Suitable size Reinforced cementconcreat (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra )(H) Weather proof hood fabricated from 5mm thick UV stablised FRP sheet supported by 50 mm x 50 mm x 5 mm Angle Iron fram above pumpset to protect it from weather All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR 450 LPM with 35 mtr head 186 Supplying and fixing Inlet Breeching Connection of CI body with Gun Metal male instantaneous inlet couplings with Inbuilt NRV, Drainage Connection with 50 mm Brass gate valvecomplete with PVC blank cap and chain as required for 150mm dia Outlet with 1 no. Matching Flange (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following Ways. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 4 Way 187 SITC of installation control valve of cast iron body and brass/bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continous alarm when the wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150mm dia 188 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 80 mm dia 189 100 mm dia 190 150 mm dia 191 200 mm dia 192 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 193 100 mm dia 194 80 mm dia 195 Supply & Fixing of Dry Powder Agent (as per IS 4308:2019), ABC typeFire Extinguisher (Stored Pressure type) conforming to IS:15683:2018 , Powder coated Internal & External Surface Deep drawn cylinder body of Mild Steel CR2 grade conforming to IS: 513, Squeeze grip Forged brass release valve with Inbuilt safety release device, Diaphragm Type, 0 to 28 bar range pressure gauge, 450 mm long EPDM discharge tube, QR code for Product Traceability including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 kg 196 Supply & Fixing of CO2 type Fire Extinguisher conforming to IS:15683:2018, charged with CO2 gas (purity 99.7% conforming to IS 15222), Powder coated Internal & External Surface Manganese steel ISI marked as per IS 7285 cylinder body , Wheel type Forged brass release valve ISI Marked as per IS 3224 with Inbuilt safety release device ((Fusible plug and Rupture Disc Type), 1.0 Mtr. Metal wire braided hose having minimum bursting pressure of 140 Kgf/cm2, Horn with metallic thread connection, QR code for Product Traceability,including Fixing on wall with suitable Anchor Fasteners as required of following capacity. Test Certificates of all the Parameters along with Hydro test & Burst test (For Cylinder Body) Certificatefrom OEM / External NABL Accrediated Lab is to be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSRCapacity 4.5 Kg. 197 Supplying and Fixing ofGalvanized Mild Steel fire bucket Confirming to IS: 2546 : 1974 with one coat of primer and two coat of enamel paint of approved shade on Angle Iron ( 50 x 50 x 5 mm) Stand of Size 800 x 1240 x 400 mm with MS 22 SWG Galvanized Canopy, 4 Hooks for Bucketsincludingassociated civil works etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED/ FIRE Indication Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light,Loop Powered / Direct powered from FACP with sound level 90 dB and programmablefrom the panel etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 SITC ofResponse Indicatorfor indicating the activation of the Remotely located Detector for Conventional type detectors as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister typeHeat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Optical/Photoelectric type smoke detectorsof photo-optic sensing chamber, 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respectswith baseas required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 1.5 sq.mm 204 3x 1.5 sq.mm 205 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR4 Pair 206 2 Pair 207 Supplying and fixingof CE certified and UL listed GI wire mesh cable tray made from spot welded steel wirehot dipped galvanised between 60 and 80 microns of zinc as per BS 729including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods,etc. as required of following sizesAll as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .500 mm x 100 mm x 6 mm 208 300 mm x 100 mm x 6 mm 209 SITC of UL 10th edition / EN54 / VDS certifiedActive Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 SITC of PA system Operator Console of following wattage to be installed withConventionalfire alarm systemcomplete with following capacity , channel mixing amplifier , 1 no cardioids goose neck microphone , 1 no professional grade cassette deck/ CD Player , 16 zone floor selector console ,equipment rack complete in all respects. PA system shall be coupled to the Fire Alarm System. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 1x 240 Watt 211 SITC 6 watt Speakermounted in M S sheet box with perforated front mesh for PA and Emergency System. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 213 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRLong point (up to 10 mtr.) 214 Long point(up to 10 mtr.) 215 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRMedium point (up to 6 mtr.) 216 Long point(up to 10 mtr..) 217 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR3x 1.5 sq.mm 218 3x 2.5 sq.mm 219 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 220 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. 221 2 x 6.0 sq. mm. 222 4 x 10.0 sq.mm 223 4 x 16.0 sq.mm 224 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 225 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 226 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 227 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 228 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 229 Three pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 230 50/63 A rating 231 100 A rating 232 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 233 50/63 A rating 234 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTwo pole 30 mA sensitivity6A-32 A rating 235 40 A rating 236 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRGlazed door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 237 Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box6Way(Incomer 8,Sub Incomer2+2+2) 238 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR6 Way(8+18) 239 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 240 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 25 Amp.2 Moduleswitch With LedIndicator 241 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 Amp. 2 Module Socket 242 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSRRJ-11 telephone jack Double line 243 RJ-45, Cat 6 computer jack with shutter 244 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1 Module 245 4 Module 246 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 247 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 6mm G.I. ( Hot Dipped) Strip 249 Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 40 mm dia. 250 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .1170mm(+/-10%) LED batten with min. lumen output 2200 lm 251 570mm (+/-10%) batten with min. lumen output 1000 lm 252 Providing & Fixing of IP20, 2x2 LED Surface/ Recessedmounting Mid power SMD type LED Light fixture not less than 50mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 4 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection(Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3600 lm 253 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimumlumen output 650 lm 254 Minimum lumen output 1950 lm 255 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 257 Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specificationsGR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. For additional technical parameters of product / work refer Annexure A attached with this BSR50 pair 258 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR25 mm 259 Supplying and fixing of ISO Certified company made Krone module with base frameas per PWD specification for electrical Works, in the recess / surface made out of 16 SWG sheet steel box, front openable, having locking arrangements duly powder painted., including dressing, ferrulingandpunchingof telephone cable with krone tool etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .50 Pairs 260 CCTV SURVEILLANCE WORKSupply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 261 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected byPVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack &ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Cat 6A, Sheilded Information Outlet 263 Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture ,material should bePC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Aperture 264 Supply, Installation, Testing and Comissioning of Rack mounted 19 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panelswith Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Modular Patch Panel Loaded with Cat -6A I/O 265 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 9 U Rackwith Width 600 mm & Depth 400 mm + 100 mm 266 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent PoE Giga Ethernet Switch providing 24 x 10/100/1000 MBPSPoE Giga Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with minimum 370 Watt PoE Power Budget with related LAN Base Software including making connections etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 268 Supply Installation testing and commissioning of 32 Ch Network Video Recorder- Connect Up to 64 IP Cameras, Up to 12 Megapixels Resolution, HDMI1/VGA1 and HDMI2/VGA2 outputs provided, atleast one HDMI output with 4K (3840 × 2160), atleast one VGA output with 2K (2560 × 1440) resolution, Support H.265/MJPEG, Supports N+1 hot spare system, Supports RAID0, RAID1, RAID5, RAID6 and RAID10, Supports HDD hot swap, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, 1 × eSATA interface, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 10 TB, Front panel: 2 × USB 2.0; Rear panel: 1 × USB 3.0, Alarm I/O 16/4, RS-232, RS-485, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface,Multiple network monitoring: Web viewer, CE, FCC, UL certified. with 30 days backup capacity asrequired. 269 SITC of professional PC alongwith printer and other accessories as required having minimum i7 processor, 8 GB graphic card 1 Tb SSD as per requirement. 270 SITC of 42 inch full HD professional LED display for CCTV monitoring. 271 External Electrical WorkS I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 KVA 272 SITC of PLC Based Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powder coated finish , Engine Start & Stopcommands, control Relays , Ammeter & Voltmeterwith selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets: Appropriate Test Certificate/ report of product/accessories from OEM/Panel Manufecturer shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .20 to 40 KVA 273 Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as requiredcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 274 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 150.0 Sq.mm 275 MAIN LT PANELSITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 276 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 277 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 278 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Shunt Trip Release 279 Under Voltage Release 280 Extended Rotary Handle 281 Auxiliary contact 282 Spreaders for 250A, 4 Pole MCCB 283 Spreaders upto 125A, 3 Pole MCCB 284 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 285 Providing & Fixing of ISO certified company made Four Pole By pass Change Over Switch conforming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .100 A 286 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 0.5 A to 5 A rating 287 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 288 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 289 50/63 A rating
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
17.
Educational and Research Institute #10336476 Price Bid
Supply Of Raw Materials (Consumable Items) Used For Training Purpose In Iti , Aluminum Round Bar 30 Mm , Aluminum Round Bar 40 Mm , Aluminum Round Bar 50 Mm , Aluminum Sheet 3 Mm , Brass Round Bar 25 Mm , Brass Round Bar 30 Mm , Brass Round Bar 35 Mm , Brass Round Bar 40 Mm , Brass Sheet 2 Mm , C.I Blank [Fabrication Of Gear] Dia 60Mm , Copper Sheet 2 Mm , Copper Tube Size (1/4, 3/8, 5/8, 1/2, 3/16) , G.I Pipe Dia ½-B- Class , G.I Pipe Dia 1-B -Class , G.I Sheet 18 Gauge , Gi Pipe 1/2 - B Class , Gi Pipe 3/4 - B Class , Gi Sheet 26 Gauge , Lead & Tin Alloy 60:40 , M.S Soft Round Bar Dia 25 Mm , M.S Soft Round Bar Dia 30 Mm , M.S Soft Round Bar Dia 35 Mm , M.S Soft Round Bar Dia 40 Mm , M.S Soft Round Bar Dia 50 Mm , M.S Soft Round Bar Dia 60 Mm , M.S Soft Square Bar 12 Mm , M.S Soft Square Bar 35 Mm , M.S Soft Square Bar 40 Mm , M.S Soft Square Bar 50 Mm , M.S Soft Square Bar 55 Mm , M.S Soft Square Bar 65 Mm , M.S Soft Square Bar 75 Mm , M.S. Soft Flat 100 X 10 Mm , M.S. Soft Flat 100 X 100 Mm , M.S. Soft Flat 25 X 3 Mm , M.S. Soft Flat 25 X 5 Mm , M.S. Soft Flat 30 X 10 Mm , M.S. Soft Flat 50 X 10 Mm , M.S. Soft Flat 50 X 12 Mm , M.S. Soft Flat 50 X 5 Mm , M.S. Soft Flat 50 X 8 Mm , M.S. Soft Flat 60 X10 Mm , M.S. Soft Flat 65 X 10 Mm , M.S. Soft Flat 70 X 12 Mm , M.S. Soft Flat 75 X 12 Mm , Ms Channel Size 75×40 , Ms Round Pipe Dia 40 Mm Medium , Ms Round Pipe Dia 50 Mm Heavy , Ms Round Pipe Dia 50 Mm Medium , Ms Sheet 2 Mm , S S Pipe 304 Size 3/4 Inch Polished , Ss Sheet Ss 304, Polised , Ss Sheet Ss 304, Non-Polised , Aaraldite (Quick Fasting) 25 M.L , Aaraldite (Quick Fasting) 50 M.L , Aaraldite 100 M.L , Aaraldite 50 M.L , Abro Tape Roll 3/4 & 5 Mtr Length , Air Valve 25 Mm , Al Bihari Kabje 180 Degree , Al Bihari Kabje 45 Degree , Al Bihari Kabje 90 Degree , Alfa Cutter 4 & 6 , Allen Bolt (3, 3.5 Mm) & Nut , Allen Bolt (4, 4.5 Mm) & Nut , Allen Bolt (6 Mm) & Nut , Allen Bolt Half Thraded(3, 3.5 Mm) & Nut , Allen Bolt Half Thraded(4, 4.5 Mm) & Nut , Allen Bolt Half Thraded(6 Mm) & Nut , Allen Bolt Half Thraded(8, 10, 12 Mm) & Nut , Ancor Fastner10 M.M , Ancor Fastner12 M.M , Ancor Fastner8 M.M , Anti Rusting Spray 200-250 Ml , Apron Used In Workshop (With 6 Pockets) , Banana Pin & Socket , Battery (12V,65Amp) , Battery Distilled Water (500 Ml.) , Battery For Clock Aa , Battery For Mike 9 V , Battery For Remote Aaa , Battery- Smf (12V 100-120Ah) , Battery- Smf (12V 60-70Ah) , Beeding Teak Wood Half Round 1 / 2 , Beeding Teak Wood Half Round 3 / 4 , Beeding Teak Wood Plain 3 / 4 , Benjo Bolt 10Mm Dia , Benjo Bolt 12Mm Dia , Benjo Bolt 15Mm Dia , Benjo Bolt 16Mm Dia , Benjo Bolt 6Mm Dia , Benjo Bolt 8Mm Dia , Benjo Washer 10Mm Dia , Benjo Washer 12Mm Dia , Benjo Washer 15Mm Dia , Benjo Washer 16Mm Dia , Benjo Washer 6Mm Dia , Benjo Washer 8Mm Dia , Blouse Hook 555 Brand , Braded Hose Pipe, Specification:-3/4 For Oxygen Gas High Pressure Heavy Duty , Brake Oil (Dot-3) , Brake Oil (Dot-4) , Brass Ball Valve 1 Inch , Brass Globe Valve 1 Inch , Brass Soldering Rod (1.5 To 3.5 Mm) , Brazzing Coperrod , Bricks (Ghol 8 X 4 X 4) , Bricks (Normal 8 X 4 X 4) , Brush (6 Inch) For Painter Use , Brush Cleaning 2 , Brush Cleaning 3 , Brush Cleaning 4 , Brush G.I. Wire 6 , Bucket With Handle (12-15 Ltr. Capasity) , C I D Joint 100 Mm , C I Pipe 100 Mm , Cabinet Door Magnet Catcher , Canvas Cloth Wirdth 4 Feet Width , Carbide Tip Tool L/H With Shank Trigular [Inserted Type Ceramic , Carbide Tip Tool R/H With Shank Trigular [Inserted Type Ceramic , Carbon Bush For Mono Block Upto 1 Hp , Cement 33 Grade , Chandraus, Specification:- (For Wooden Polish) , Chapdi For Wooden Polish , China (Bugle Head) Screw - Self Threaded Conical Head Screw- (3 X 10 Mm, 4 X 10 Mm) , China (Bugle Head) Screw - Self Threaded Conical Head Screw- (4 X 15 Mm, 4 X 18 Mm) , China (Bugle Head) Screw - Self Threaded Conical Head Screw- (5 X 15 Mm, 5 X 18 Mm) , China (Bugle Head) Screw - Self Threaded Conical Head Screw- (5 X 25 Mm, 5 X 35 Mm) , China (Bugle Head) Screw - Self Threaded Conical Head Screw- (5 X 40 Mm, 5 X 50 Mm) , Cloth 100% Cotton Printed Fine(44 / 36 Inches Width) , Cloth Blouse Piece (Rubiya), Different Colour , Cloth Bukram / Dhoti Bukram , Cloth Cotton Waste (Hoisry) , Cloth Poplin Coloured (44 / 36 Inches Width) 100% Cotton ,Light Colours , Cloth Rubia Plain (44 / 36 Inches Width) 2X2 Rubia ,Light Colours , Colour Spray Bottles 500 Ml Size (Different Colours) , Coloured Thread Reel Packed , Concealed Flush Tank , Conduet Couplor 1 , Copper Tube Gas Charging , Cotton Balls - 200 Grm. For Cosmetology , Cotton Tape , Specification :- (Two Contrast Colours) , Cotton Thread Reel White Medium Size For Cutting Sewing , Cotton Waste White Colour , Cp Angle Cock Half Round 15 Mm , Cp Angle Push Cock 1/2 Inch , Cp Bib Cock Half Round 15 Mm , Cp Brass Diverter 1/2 Inch 4 Way , Cp Piller Cock Half Round 15 Mm , Cp Push Cock 1/2 Inch , Cp Push Flush Valve 1.25 Inch , Cp Sensor Type Pillar Cock 1 Inch , Cp Two Way Bib Cock 1/2 Inch , Cp Waste Coupling 32 Mm , Cpvc 3 Way Elbow 3/4 Inch , Cpvc 3 Way Valve 3/4 Inch , Cpvc Ball Valve 1 Inch , Cpvc Ball Valve 3/4 Inch , Cpvc Bush 1 - 3/4 Inch , Cpvc Cap 1 Inch , Cpvc Cap 3/4 Inch , Cpvc China Clamp 1 Inch , Cpvc China Clamp 3/4 Inch , Cpvc Cross Over 1 Inch , Cpvc Cross Over 3/4 Inch , Cpvc Elbow 1 Inch , Cpvc Elbow 3/4 Inch , Cpvc Elbow 45 Degree 1 Inch , Cpvc Elbow 45 Degree 3/4 Inch , Cpvc Elbow Fta 1 Inch , Cpvc Elbow Fta 3/4 Inch , Cpvc Pipe 11 Sdr 1 Inch , Cpvc Pipe 11 Sdr 3/4 Inch , Cpvc Reducer 1 - 3/4 Inch , Cpvc Socket 1 Inch , Cpvc Socket 3/4 Inch , Cpvc Socket Fta 1 Inch , Cpvc Socket Fta 3/4 Inch , Cpvc Socket Mta 1 Inch , Cpvc Socket Mta 3/4 Inch , Cpvc Solvent 100 Gm Pack , Cpvc Solvent 250 Gm Pack , Cpvc Solvent 50 Gm Pack , Cpvc Step Over Bend 3/4 Inch , Cpvc Tank Nipple 1 Inch , Cpvc Tank Nipple 3/4 Inch , Cpvc Tee 1 Inch , Cpvc Tee 3/4 Inch , Cpvc Thread Tee 3/4 Inch , Cpvc Union 1 Inch , Cpvc Union 3/4 Inch , Crocodile Clips 2 Amp, 6 Amp , Curling Rod Plane For Hairing - 32 Mm , Curling Rod Zig-Zag For Hairing , Curtain Bracket - Wall To Wall (Pair) , Curtain Pipe End Cap (S S) , Cutting Grinder Wheel 4 , Cutting Oil Aqua Cut 125 Soluble Oil , Cutting Oil Servo Cut Xl , Cutting Scissor For Hair Cutting (Biger) , Cutting Scissor For Hair Cutting (Smaller) , Cutting Tool H.S.S (1/2 X 6 Mirinda & Metro) Tungsten 18%,Chromium 4%,Vanadium 1%,Cobalt 1%,Carbon 0.6% , Cutting Tool H.S.S (3/4 X 6 Mirinda & Metro) Tungsten 18%,Chromium 4%,Vanadium 1%,Cobalt 1%,Carbon 0.6% , Cutting Tool H.S.S (3/8 X 6 Mirinda & Metro) Tungsten 18%,Chromium 4%,Vanadium 1%,Cobalt 1%,Carbon 0.6% , Cutting Wheel, Specification:- ?100Mm Cobalt , Deco Paint 1 Ltr. Pack (Off White, Pink & Brown Colour) , Deco Thinner500 Ml. Pack , Door Handle (S S) Size 4 , Door Handle (S S) Size 6 , Door Handle (S S) Size 9 , Door Hinges (S S) Size 3/4 X 3/4 - 6 Feet , Door Stoper , Dry Cell 9 V , Duble Door Refrigerator Timer , Ductile Iron Pipe 6 Dia (Socket & Spigot Joint With Rubber Ring) 10 Feet , Dustbin (Office Used 5 Ltr. Capecity) , Dustbin (Outdoor Used 15 Ltr. Capecity) , Dustbin (Outdoor Used 20 Ltr. Capecity) , Earth Plate (Size - 2 X 2) , Elastic Dress Material Width 1 Imported Quality , Elastic Dress Material Width 1/2 Imported Quality , Elastic Dress Material Width 1/4 Imported Quality , Embroidery Threads 100 Grm. Different Colour , Emery Paper Cloth Grit 100, 120 To 150 , Emery Paper Rough (A-4 Paper Size) 100, 120, 150 , Enamal Oil Paint (Black) 1 Ltr. , Enamal Oil Paint (Black) 10 Ltr. , Enamal Oil Paint (Black) 2 Ltr. , Enamal Oil Paint (Black) 4 Ltr. , Enamal Oil Paint (White) 1 Ltr. , Enamal Oil Paint (White) 10 Ltr. , Enamal Oil Paint (White) 2 Ltr. , Enamal Oil Paint (White) 4 Ltr. , Engine Oil (5W-30 Castrol) , Engine Oil (Sae 10W40) , Engine Oil Sae 15W40 , Expansion Joint 100 Mm , Fabric Alpin Beaded Rust Proof Fine Point , Fevicol Heatax (Sr) 1000 Gram , Fevicol Heatax (Sr) 2000 Gram , Fevicol Heatax (Sr) 250 Gram , Fevicol Heatax (Sr) 500 Gram , Fevicol Heatax (Sr) 5000 Gram , Fevicol Sh 1000 Gram , Fevicol Sh 2000 Gram , Fevicol Sh 250 Gram , Fevicol Sh 500 Gram , Fevicol Sh 5000 Gram , File Handle (Ø4) , File Handle (Ø6) , First Aid Box - For Medical , Flange Joint 1 Inch , Flare Nut, Specification:- 1/2 , Flare Nut, Specification:- 1/4 , Flare Nut, Specification:- 3/8 , Flexible Joint 100 Mm , Float Valve Brass 1 Inch , Float Valve Brass 1/2 Inch , Funnel Plastic With 19 Mm Dia. , G I Cap 1/2 Inch , G I Cross 1/2 Inch , G I Elbow 1 Inch , G I Elbow 1/2 Inch , G I Elbow 3/4 Inch , G I Hex Nipple 1 Inch , G I Hex Nipple 1/2 Inch , G I Hex Nipple 3/4 Inch , G I Pipe B Class 1 Inch , G I Pipe B Class 1/2 Inch , G I Pipe B Class 3/4 Inch , G I Plug1/2 Inch , G I Socket 1 Inch , G I Socket 1/2 Inch , G I Socket 3/4 Inch , G I Tee 1 Inch , G I Tee 1/2 Inch , G I Tee 3/4 Inch , G I Union 1 Inch , G I Union 1/2 Inch , G I Union 3/4 Inch , G.Iunion (ؽ-B) , G.Iunion (Ø1-B) , G.I Bend (ؽ-B) , G.I Bend (Ø1-B) , G.I Elbow (ؽ-B) , G.I Elbow (Ø1-B) , G.I Gate Valve (ؽ-B) , G.I Gate Valve (Ø1-B) , G.I Socket (ؽ-B) , G.I Socket (Ø1-B) , G.I Tee (ؽ-B) , G.I Tee (Ø1-B) , G.I. Wire Each 10 Swg , G.I. Wire Each 14 Swg , G.I. Wire Each 16 Swg , Gate Valve 1 Inch , Gear Oil 20 W 40 No. Grade , Gear Oils (75W90) , Gi Bend 12.7 Mm Dia. , Gi Chuck Nut For 19 Mm Dia. , Gi Nut & Bolt 19 Mm Dia. , Gi Plate 300 Mm X 300 Mm X 3 Mm , Gi Washer Plane 3/4 , Gi Wire 4Mm , Gitti Black 1/2 (A Lot Of 75 Cu. Feet) For Measonery Work , Gitti Black 3/4 (A Lot Of 75 Cu. Feet) Measonery Work , Glands Cotton 10 Sq. Mm , Glands Cotton 12 Sq. Mm , Glands Cotton 15 Sq. Mm , Glands Taflon 10 Sq. Mm , Glands Taflon 12 Sq. Mm , Glands Taflon 15 Sq. Mm , Glass Cutter , Glazed Cotton / Rayon (44 Inches Width) , Gloves For Welding (Asbestos) , Gloves For Welding (Leather) , Greese (Nl Gi-3) / Ap-3 Pack To 1 Kg. , Greese (Nl Gi-3) / Ap-3 Pack To 10 Kg. , 3 Pin Plug Top Each 6 Amp,16 Amp , 5 Pin Scoket 15 Ampr-230 Volt , 5 Pin Socket 5 Ampr-230 Volt , Aluminium Armed Cable-3 Core 20 Mm , Aluminium Armed Cable-3 Core 35 Mm , Aluminium Armed Cable-3.5 Core 50 Mm , Aluminium Wire 3/22 , Aluminium Wire 7/22 , Bar Magnet , Binding Wire (For Britania Joints) Alloy 18 Swg , Bulb (Normal) 100 Watts , Bulb (Normal) 200 Watts , Bulb (Normal) 40 / 60 Watts , Bulb Led Each 15 Watts , Bulb Led Each 20 Watts , Bulb Led Each 5 Watt , Bulb Led Each 9 Watt , Buzzer , Cable 3 -Core2.5 Sq. Mm Copper , Cable Copper (2 Core) 1Mm , Cable Copper( 3 Core) 1.5 Sq. Mm , Cable Copper( 3 Core) 2.5 Sq. Mm , Capacitor 2.5 M.F.D Dual , Capacitor 25 Volt 1000 Mfd , Capacitor 50 M.F.D Dual , Capacitor Each 2, 2.5 Mfd (240V) , Capacitor Each 4 Mfd (240V) , Capacitor Each 8 Mfd (240V) , Capacitor Electrolite470ufd/25V , Capacitor Electrolite 1000 Ufd/25 V , Capacitor Electrolite 220 Ufd/12V/100Ufd /12V/10 Ufd/16V , Carbon Registance Of Differnet Value In K.Ohms/ M. Ohms 1 Watt. 10 K, 50K, 100K, 1M, 2.2M Ohms , Casing Caping 1 , Casing Caping 3/4 , Casing Caping Corner (L- Shape) 3/4 & 1 , Casing Caping Corner (T- Shape) 3/4 & 1 , Ceiling Rose 6 Amp , Choke Each 40 W, 250 V (Aluminium) , Color Wire Strip Multistand Wire , Conduit Pipe 1 , Conduit Pipe 3/4 , Contactor Single Pole , Crimping Ferrules Each 4Mm, 10 Mm , Diac , Diode4148 , Diodein-4001 To 4007 , Diode In 34 , Diode In 5404 , Diode In 5405 , Diode In-5412 Amp , Diode Oa 79 , Diode Oa 79/In 34 , Electrical Soldering Wire , Electrical Wire, Multistand,Copper Wire 1 Sqm , Electrical Wire, Multistand,Copper Wire 1.5 Sqm , Electrical Wire, Multistand,Copper Wire 2.5 Sqm , Emery Sleeve (1-6 Mm) , Fan Regulator Modular 6 Amp , Flexible Wire, 128/0.20 , Flexible Wire, 140/0.30 , Flexible Wire, 85/0.30 , Fuse ( Flush Type) Each 3 Amp To 30 Amp , Fuse Wire 22 - 26 Gauge , Gang Box Pvc 4 X 8 , General Purpose Lug Board , Geyser 10 Ltr Capacity C&G / Bajaj , Geyser 5 Ltr Capacity C&G / Bajaj , Geyser Heating Element1500 W, 250 V , Geyser Heating Element2000 W, 250 V , Geyser Heating Element3000 W, 250 V , Geyser Thermostat500 W, 250 V , Glue Gun Heavy Duty 40 Watt High Temp. Pen (Indian Brand) , Hard Drawn Bare Copper Wire 4 Mm2 , Holder (Backelite) Pendent Type 6 Amp , Hookup Wires , Horse Shoe Magnet , Hot Air Gun - 230 Volt, 1500 Watt (Indian Brand) , I.C 1031 , I.C 1353 , I.C 555 , I.C 7400/7408/7410 , I.C 741 , I.C 74109 , I.C 7432 , I.C 7476/7486 , I.C 7805/7905 , I.C Base 16 Pin (Best Quality), Lm317 , I.C Bel 1895 , I.C Ca 3065 , I.C Ka 2101 , I.C Ta 1366 , I.C Ta 7699/7680 , I.C Tba 810 , I.C Tda 1670A , I.C Tda 1940 , I.C Tda 356 Ia , I.C Tda 4440 , I/O Box With Socket , Impregnated Cotton Tape 25 Mm , Industrial Scocket 16 Amp , Industrial Switch 16 Amp , Industrial Switch-Scocket Combined 16 Amp , Insulation Tape 1/2 , Insulator (Types- Shackle & Pin) Each Small Size , Intermediate Switch Modular 6 Amp , Kettle Element500 W, 250 V , Knife Switch Dpst 16 Amp , Lamp Holder (Backelite) Angle Type 6 Amp , Lamp Holder (Backelite) -Batten Type 6 Amp , Lamp Holders, (Normal) , Leatheroid Paper 2 Mills , Led Bulb Indicator R,Y,G - 15 Watt , Led Different Color - 1.5 Volt , Low Pressure Mercury Lamp (Lpmv) 40 W , Lugs/ Thimble (Aluminium) 10 Mm , Lugs/ Thimble (Aluminium) 12 Mm , Lugs/ Thimble (Aluminium) 18 Mm , Lugs/ Thimble (Aluminium) 25 Mm , Lugs/ Thimble (Aluminium) 6 Mm , Mcb 16 Amp , Mcb 2 Pole 32 Amp , Mcb 32 Amp , Mcb 6 Amp , Mcb Box ( Double Door) 10 Module , Mcb Box ( Double Door) 12 Module , Mcb Box ( Double Door) 2 Module , Mcb Box ( Double Door) 4 Module , Mcb Box ( Double Door) 6 Module , Mcb Tpn 32 Amp , Mcb Tpn 63 Amp 230 Volt , Mccb100 Amp 3 Pole , Mercury Vapour Lamp ( Mv Lamp) 240 W , Miniature Pack Each 6 V/9V , 300 Ma , Mv Lamp Choke( Mv Lamp) 240 W , Mv Lamp/ Holder( Mv Lamp) 240 W , Nichrome Wire 18 Swg , One Way Switch Modular 16 Amp , One Way Switch Modular 6 Amp , Photo Diode Bpx 65 (Good Quality) , Photo Transistor 6 An-137 , Photo Transistor 6N317 , Plug Top 3 Pin 15 Ampr/ 220 Volt , Plug Top 3 Pin 5 Ampr/ 220 Volt , Power Cord- 3 Core 16 Amp Copper , Printed Circuit Board Size 4X4, 6X4 Copper Layar , Push Button Switch 6 Amp, 250 V , Pvc Clip (China Clip) 10 , Pvc Clip (China Clip) 12 , Pvc Clip (China Clip) 2 , Pvc Clip (China Clip) 20 , Pvc Clip (China Clip) 25 , Pvc Clip (China Clip) 5 , Pvc Clip (China Clip) 6 , Pvc Clip (China Clip) 8 , Pvc Elbow 3/4 & 1 , Pvc Elctrical Board 8X10 , Pvc J. Box ( 2 Way) 3/4 & 1 , Pvc J. Box ( 4 Way) 3/4 & 1 , Pvc J. Box (3Way) 3/4 & 1 , Pvc Rawl Plug , Reflector Lamp 100 W , Registance Diff. Valve In K Ohms/ M Ohms , Registance Of Differnet Value In K.Ohms/ M. Ohms 1/2 Watt. 10 K, 50K, 100K, 1M, 2.2M Ohms , Registance Of Differnet Value In K.Ohms/ M. Ohms 1/4 Watt. 10 K, 50K, 100K, 1M, 2.2M Ohms , Relay - Up To 6, 8, 10 Amp , Relay Freezge All Type , Rj 45, 1.5 Amp, 20 Micro Ohm, Cat 5 Transparent , Rotor Swicth , Scr Tyn-612 , Silver Bowl Lamp 100 W , Socket Modular (5 Pin) 16 Amp , Socket Modular (5 Pin) 6 Amp , Solar Cells 12 Smw/ Cm2/ 0.45 V, 57 Ma , Soldering Element 25 Watt 220 Volt , Solenoid Coil , Square Gang Box Pvc 4 X 4 , Street Light Led Each 100 Watt , Street Light Led Each 30 Watt , Street Light Led Each 50 Watt , Super Enameled Copper Wire Each 14,20,24,26,30,32,35, 36,42 Swg , Surface Plastic Box 12 Module , Surface Plastic Box 18 Module , Surface Plastic Box 3 Module , Surface Plastic Box 4 Module , Surface Plastic Box 6 Module , Surface Plastic Box 8 Module , Surface Plastic Cover Plate12 Module , Surface Plastic Cover Plate18 Module , Surface Plastic Cover Plate3 Module , Surface Plastic Cover Plate4 Module , Surface Plastic Cover Plate6 Module , Surface Plastic Cover Plate8 Module , Switch5 Ampr-230 Volt (Normal) , Switch 15 Ampr-230 Volt (Normal) , Toggle Switch Spst , Transformer 12-0-12, 220 Volt , Transformer 6-0-6, 220 Volt , Transformer Bobbin (Plastic) Each Small & Medium Size , Transistor 2 N 5296 , Transistor 2 N 6111 , Transistor 2 N 820 , Transistor 2N 3055 , Transistor Ac 127 , Transistor Ac 128 , Transistor Ac 188 , Transistor Bc 149 , Transistor Bc 194B , Transistor Bc 547 , Transistor Bc115 , Transistor Bel 369 , Transistor Bf 194 B , Transistor Bf 195 , Triac , Tubelight Fitting Single Patti (1200 Mm) , Tubelight Holder Plain , Tubelight Led Each 18 And 20 Watts - 4 Feet Length , Tubelight Starter Each 40 W, 250 V , Tubelight Starter Holder , Two Way Switch5 Ampr-230 Volt (Normal) Havell Company , Two Way Switch Modular 6 Amp , Wire Wound Register 5/7 Watt Different Value , Zener Diode 12 Volt , Zener Diode 6 Volt , Acrylic Colour Set (Camel) , Alpin (T-Pin) For Stationary Purpose 100 Gram , Ang Vastra (To Celebrate Dikshant Samaroh Ceremony) , Artist Colour Plate (Wooden/Plastic) , Ball Pen Colour- Black Make-Flair, Butterflow, Reynolds , Ball Pen Colour- Blue Make-Flair, Butterflow, Reynolds , Ball Pen Colour- Red Make-Flair, Butterflow, Reynolds , Butter Paper Sheet Size Standard , Cable Cat 5, 10Gb Per Sec. High Speed Ethernet Cable , Carbon Paper (Blue/Black) Size A-4 , Cartridges For Printer Canon Model - F164102, 3.2 A , Cartridges For Printer Canon Model - Lbp162dw , Cartridges For Printer Hp Model - Laserjet 137Aw, 1370A , Cartridges For Printer Hp Model - Laserjet P1606dn , Cartridges For Printer Hp Model - Laserjet Pro Mfp(M1281w) , Cartridges For Printer Sharp Model - Mx-315At , Cartridges For Printer Sharp Model - Mx-M265nv , Ceilo Tape 3/4 Or 1/2 , Chalk White For Black Board (Non-Stick) , Charcoal Pencil Set Different Colour , Color Chalk For Black Board (Non-Stick) , Computer Power Chord , Dak Pad (Ragine) , Degree Folder Full Size (Executive) For Tranferring Degree/Mou , Drawing Board Pin Box , Drawing Sheet Colour A2 , Drawing Sheet White / Off White - A2 , Drawing Sheeta1 (841/594Mm) White/Off White , Duster Cloth 2’/2’ , Electronic Cordless Bell , Envelop Plain White 12X25 Cm , Envelop Size A4 Yellow , Envelop Size A4 Yellow With Inner Laminated , Fabric Colour Set (Camel) , File Cover Office , File Coverpad Office , File Flag Pack , File Folder Plastic Bag , File Office Tag (Smaller) 6,12Bundle-100 Piece , File Office Tag 12Bundle-100 Piece , Gel Pen Colour- Blue, Black Make-Flair, Butterflow, Reynolds , Glossy Paper A-4 Size 150 Gsm , Glu Stick Smaller Size 15 Ml , Graph Sheet A1 (841/594Mm) , Gum Bottle 100 Ml , Gum Bottle 700 Ml , Highlighter Luxer Blue, Yellow, Green, Pink , Key Board , Legal Size Paper Fs , Legal White Paper Fs , L-Folder , Magnetic Pen For Smart Board (Different Colour) , Magnetic White Board Duster , Note Book (Lining) 192 Pages , Note Book (Lining) 96 Pages , Note Pad Approx 25 Page (Executive) , Note Pad Approx 25 Page (Normal) , Ohp Marker - Cds / Dvd Marker Different Colour , Oil Tube Colour Set (Student Colour) , Optical Mouse , Paramanent Marker Pen Thick Red & Black , Paramanent Marker Pen Think Red & Black , Pen Drive 16 Gb Sony / Hp Make With C-Connector , Pen Drive 32 Gb Sony / Hp Make With C-Connector , Pen Drive 64 Gb Sony / Hp Make With C-Connector , Pencil & Eraser (Hb, H, H-1, B-1) Kohinoor / Apsara , Pencil Colour,Wax Colour , Photo Copy Paper A3 Size 75 Gsm , Photo Copy Paper A4 Size 75 Gsm , Poster Colour Set (Camel) , Power Adapter 5 Volt 2Amp Pin Type , Power Adapter 7.5 Volt 2Amp Pin Type , Register 1 Quir 8/13 (72 Pages) , Register 2 Quir 8/13 (144 Pages) , Register 3Quir 8/13 (216Pages) , Register 4 Quir 8/13 (288 Pages) , Register 8 Quir 8/13 (576 Pages) , Shorthand Pencil Pack , Skecth Pan Set , Sketch Colour Set , Sketching Book (A3,A4) , Stapler Big (26/6) , Stapler Pin Big (26/6) , Stapler Pin Small (24/6) , Stapler Small (24/6) , Steno Note Book (Lining) 190 Pages , Thermacoal Sheet 1 Thickness Size Standard , Thermacoal Sheet 2 Thickness Size Standard , U Pin Plastic Coteded , White Board Marker Different Colour Pack , White Board Marker Pen Different Colour , White Borad With Stand 2 X 3 , White Borad Without Stand 2 X 3 , Whitner Pen (Correction Pen) 9 Ml , Air Freshner Gel (Oddonil/Acer) 30 Ml , Air Freshner Solid For Toiletry Purpose (Oddonil/Acer) 100 Grm. , Bamboo Stick (Danda) 4 Feet Long With 1 Dia , Boom Stick (Jhadu) For Commericial Use , Boom Stick (Jhadu) For Domestic Use , Car Freshner , Coffee Nascaffe / Brittaniya 50 Grm. Poch , Door Mate 2 X 3 1/2 Feet (Cotton) , Door Mate 2 X 4 1/2 Feet (Cotton) , Dusting Cloth Cotton 22 X 22 , Dusting Cloth Pochha Cotton 22 X 22 , Floor Cleaning Liquid 500 Ml , Glass Cleaner (500 Ml) Colin Or Equivalent Brand , Green Tea Bags (Poch) , Hand Wash Liquid 500 Ml (Dettol / Savlon) , Hit Black 700 Ml , Hit Red 700 Ml , Mob Dry (Micro Fiber) 4 , Mob Wet (Micro Fiber) 4 , Mosquito Killer Machine , Mosquito Killer Reffil , Phenaiyel Balls Normal Brand 250 Grm. Pack , Phenaiyel Liquid Doctor Brand 500 Ml Pack , Phenaiyel Liquid Normal Brand 500 Ml Pack , Phool Stick (Jhadu) , Plastic Bath Mug 500 Ml , Pvc Stick (Jhadu) With 3 Feet Pvc Pipe Handle For Roof (Fall Ceilling) Cleaning Purpose , Room Freshner Spray 500 Ml , Rubber Wiper 2 Feet With 3 Feet Pvc Pipe Handle For Floor Cleaning Purpose , Tea Dust (250 Grm.) Brooke Bond / Bagh Bagri , Tissue Paper (Two Piy Facial) 100 Pulls In Box , Toilet Nylon Hand Brush 4 , Toilet Wooden Hand Brush 4 , Toiletry Cleaning Liquid 500 Ml Harpic Brand , Toiletry Cleaning Liquid 500 Ml Local Brand , Toiletry Cleaning Liquid Acid 500 Ml , Towel (Chair) 14 X 21 (Cotton) 600 Gsm , Towel (Face Cleaning) 1 X 1 Feet (Cotton) 450 Gsm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
Madhya Pradesh View Result →
18.
Public Administrative Department #10226673 Price Bid
Supply, Installation And Commissioning Of Machines, Tools And Equipment For New Age Courses In Itis Of Jharkhand Selection Of Agency For Supply, Installation And Commissioning Of Machines, Tools And Equipment For New Age Courses In Itis Of Jharkhand , A. General Tools , Pliers , Soldering Station , Multi Meter , Tweezers , Binoculars , Anemometer , Magnifier , B. List Of Equipment , Unassembled Drone , Electricity Lab , Smd Technology Kit With Wall Chart , Multiple Output Dc Regulated Power Supply , Dc Regulated Variable Programmable Dc Power Supply , Smart Smd Tweezer Handheld , 1 Mhz Mixed Signal Oscilloscope ( 4 Analog + 16 Digital Channel) , 25 Mhz Arbitrary Waveform Generator With Digital Display For Frequency And Amplitude , Handheld 3 3/4 Digit Multimeter , 3Ghz Spectrum Analyzer With Built-In Tracking Generator , Smd Soldering & De Soldering Station With Necessary Accessories , Or Drone Workbench , Analog-Digital Circuits Development Platform , Applied Mechanics Training Platform , Drone Battery Management Training Systems , Charge Controller Training System , Bldc (Brushless Dc) Motor Training System , Inverted Pendulum , Drone Sensor Trainer Kit , Antenna Training System , Advanced Microwave Integrated Circuit Lab , Gps Training Platform , Wireless Communication Modules , Fcb And Esc Training Platform , Drone Gimbal Set With Motor And Control , Npnt Compliant Micro Uav Built For Mapping And Surveillance. , Hd Payload , Thermal Camera Payload , Field Repair Kits , Drones And Spare Parts Kit , Balance Charger , Power Distribution Board , Laptop Latest Configuration , Thrust Measurement Meter , Indoor Netted Facility , Outdoor Controlled Netted Testing Facility , Different Types Of Electronic And Electrical Cables, Connectors, Sockets, Terminations, Different Types Of Analog Electronic Components, Digital Ics. , 3D Printer , Drone Upto 18Km , A. Trainees Tool Kit (Foradditional Unit Trainees Tool Kit Sl. 1-12 Is Required Additionally) , Connecting Screwdriver , Neon Tester 500 V. , Screwdriver , Insulated Combination Pliers , Insulated Side Cutting Pliers , Long Nose Pliers , Soldering Iron , Electrician Knife , Tweezers , Digital Multimeter With 4000 Counts, Large Display With Auto/Manual And Can Measure Dcv- 1000V-Acv-750V, Dc & Ac A(Minimum) – 10A, Resistance (Minimum) 40M?, Capacitance Minimum 20?F, Capacitance And Frequency (Minimum)– 3 Mhz , Soldering Iron Changeable Bits , De- Soldering Pump Electrical Heated, Manual Operators , B. Shop Tools, Instruments – For 2 (1+1) Units No Additional Items Are Required , Steel Rule Graduated Both In Metric And English Unit , Precisionof Screw Drivers , Tweezers – Bend Tip , Steel Measuring Tape , Tools Makers Vice , Tools Maker Vice , Crimping Tool (Pliers) , Magneto Spanner , File Flat Bastard , File Flat Second Cut , File Flat Smooth , Plier - Flat Nose , Round Nose Pliers , Scriber Straight , Hammer Ball Pen , Allen Key(Hexagonalof 9) , Tubular Box Spanner , Magnifying Lenses , Continuity Tester , Hacksaw Frame Adjustable , Chisel - Cold - Flat , Scissors , Handsaw 450Mm , Hand Drill Machine Electric With Hammer Action , First Aid Kit , Bench Vice , List Of Equipments , Multiple Output Dc Regulated Power Supply , Dc Regulated Variable Programmable Dc Power Supply , Lcr Meter (Digital) Handheld , 70 Mhz Mixed Signal Oscilloscope ( 4 Analog + 16 Digital Channel ) , 25 Mhz Arbitrary Waveform Generator With Digital Display For Frequency And Amplitude , 6 1/2 Digit Digital Multimeter , 3Ghz Spectrum Analyzer With Built-In Tracking Generator , Or Electronics Workbench , Multi Function Test & Measuring Tool For Field Applications And Testing Compatible With Laptop , Electrical Safety Trainer , Analog Component Trainer With Following Seven Basic Modules • Diode Characteristics (Si,Zener,Led) • Rectifier Circuits • Diode As Clipper Circuit • Diode As Clamping Circuit • Zener As Voltage Regulator. • Transistor Type Npn & Pnp And Ce Characteristics • Transistor As A Switch , Digital Ic Trainer , It Workbench For Computer Hardware And Networking , Laptop Latest Configuration , Laser Jet Printer , Internet Broadband Connection , Electronic Circuit Simulation Software With Five User Licenses , Different Types Of Electronic And Electrical Cables, Connectors, Sockets, Terminations. , Different Types Of Analog Electronic Components, Digital Ics, Power Electronic Components, General Purpose Pcbs, Bread Board, Mcb, Elcb , Smd Soldering & De Soldering Station With Necessary Accessories , Smd Technology Kit , Microcontroller Kits (8051) Along With Programming Software (Assembly Level Programming) With Six Important Different Application Modules 1. Input Interface Switch, Matrix Keypad, Ascii Keypad 2. Display Lcd, Seven Segment, Led Matrix 3. Adc & Dac 4. Pc Interface Module 5. Motor Dc, Stepper, Servo 6. Daq , Sensor Trainer Kit Containing Following Sensors A)Air Humidity And Temperature B)Rtd C)Atmospheric Pressure D)Air Quality E)Smoke Detector Sensors F) Limit Switch G)Photo Sensors H)Capacitive Displacement , Different Types Of Electronic And Electrical Cables, Connectors, Sockets, Terminations. , Different Microcontroller/Processor Training And Development Platform For Avr, Pic, Arm And Ardui , Internet Of Things Explorer , Field Interface And Protocol Simulation Kit , List Of The Machineries , Solar Power Lab , Solar Pv Module Analyzer , Wireless Communication Modules For Interfacing With Microcontrollers A) Rfid Card Reader B) Finger Print C) Zigbee D) Gps E) Gsm F) Bluetooth G) Wifi , Sensors For Smart Environment Application , Sensors For Smart Parking , Sensors For Smart Water & Waste Water Management And Monitoring , Weather Monitoring System , Smart Solar Street Lighting Training Platform , Iot Based Smart Streetlight System , Smart Transportation Monitoring System , Sensors For Smart Building , Iot Data Acquisition Systems And Protocol Converters , Iot Edge Computing Device , Cloud Based Iot Scada , D. Shop Floor Furniture And Materials - For 2 (1+1) Units No Additional Items Are Required. , Instructor’S Table , Instructor’S Chair , Metal Rack , Lockers With 16 Drawers Standard Size , Steel Almirah , Interactive Smart Board With Projector , Fire Extinguisher , A. Trainees Tool Kit , Steel Rule , Hand Gloves , Safety Shoes , Helmet , B. Tools, Instruments And General Shop Outfit , “V” Block , “V” Block , Micrometer Outside , Vernier Caliper , Micrometer Inside , Metal L , Metal L , Angle Plate , Spirit Level , File Warding , File Knife Edge , File Cut Saw , File Feather Edge , File Triangular , File Round , File Square , File Square , File Triangular , File Flat , File Flat , File Flat , File Swiss Type , File Half Round , File Half Round , File Round , File Hand , Card File. , Oil Stone , Pliers Combination , Blow Lamp , Spanner , Spanner Adjustable , Box Spanner , Glass Magnifying , Clamp Toolmaker , Clamp “C” , Clamp “C” , Scraper Flat , Scraper Triangular , Scraper Half Round , Chisel , Chisel , Chisel , Motorized +Tenn Saw , Hand Hammer , Hacksaw , Mallets Wooden , V-Block, Files, Mallets, Screwdrivers, Chisels, Etc. , Hand Drilling Machine , Metal Saw , Straight Grinder Heavy Duty With Attachments , Professional Air Blower , Jig Saw Portable , Hammer Drill Wired , Hand Held Sander / Polisher , Digital Dial Torque Wrench , Lifting Tackle/Sling , Impact Wrench , Laser Light Pen , Surface Plate , Digital Screw Pitch Gauge , Laser Distance Measurement Instrument , Palm Scale , Allen Screwdriver Wrench Tool , Universal Quick Adjustable Multi-Function Wrench Spanner , Double Ended Wrench Hex Socket Spanner , C. General Machinery / Software Installations (Automobile Bom) , Car Lift -4 Ton , 2 Wheeler Bike Or Scooter Assembly Set , Transmission / Gearbox Demo Kit , Cooling System Components Arranged On A Stand With Electric Motor , Exhaust System , Mini Commercial Vehicle Chassis Structure , Rear Axel , Suspension System-Front And Rear On Stand , Steering Wheel And Tyre Systems Assembly On Stand , Disc 7 Drum Brake Systems On Stand (Working Model) , Engine And Transmission Systems On Stand (Working Model) , Hvac Demo Kit , Electronic Ignition System Of An Automobile 4 Wheeler , Demonstration Board Of Working Model Mpfi System With Motorized Control , Instruction Kit For Charging System , Instruction Kit For Starting System , Lighting And Wiring System Mock Layout , System Set Up And Integration With Design. , Electric Vehicle , Electric Vehicle Kit Chassis (In Sets) , Multimeter Digital , Ammeter Able To Read Upto 300 A , Continuity Tester , Tyre Pressure Gauge , Measuring Tape , Electrical Soldering Iron , A. Trainees Tool Kit , Steel Rule , Engineer’S Square , Bevel Straight Edge , Centre Punch , Dot Punch , File Flat Bastard , File Flat 2Nd Cut , File Flat Safe Edge , File Triangular Rough , Hammer , Scriber , Vernier Caliper , Micrometer (Outside) , Safety Goggles (Personal Protective Equipment) , Screw Driver Electrician , Screw Driver , Long Nose Plier , Combination Plier , Diagonal Cutter , Screw Driver Philips , Tweezers , Knife , Wire Stripper , Neon Tester , Scissors , Soldering Iron , Bread Board , B: Tools And Equipments: , Caliper Outside , V-Block , Divider – 150 Mm , Screw Driver , Circlip Plier (Inside And Outside) Each , Centre Gauge , Oil Can , Oil Gun And Grease Gun Each , File Flat Smooth , File Flat Smooth , File Half Round Bastard , File Half Round Smooth , File Triangular Smooth , File Round Bastard , File Square Smooth , Knife Edge File , Needle File Assorted (12 Nos.) , File Card (Spattle) , Scraper Flat , Hammer Ball Peen , Hammer Cross Peen , Chisel Cold Flat , Chisel Cross Cut , Chisel Half Round , Chisel Diamond Point , Scribing Block , Cast Iron Surface Plate , Granite Surface Plate , Tap Extractor , Screw Extractor , Hand Taps And Dies , Bench Vice , Machine Reamer , Machine Tap Set , Twist Drill , Twist Drill , Taper Shank Drills , D.E Spanners , Letter Punch , Number Punch , Parallel Block Standard Sets , Allen Key Metric , Centre Drills , Parallel Hand Reamer , Star Dresser , Diamond Dresser With Holder , Surface Gauge , Angle Plate-Adjustable , Micrometer –Inside – Outside , Vernier Caliper With 0.02Mm Least Count , Digital Vernier Caliper , Digital Micrometer( Inside, Outside And Depth ) , Height Gauge , Vernier Bevel Protractor , Sine Bar And Sine Centre Each , Sprit Level , Slip Gauge Set ( Std ) , Magnetic Stand , Dial Test Indicator , Dial Test Indicator , Bore Gauge , Straight Edge-Single Beveled , Tool Maker’S Clamp , C – Clamp- , Bearing Puller , Ammeter , Ammeter , Voltmeter , Pf Meter , Phase Sequence Meter , Digital Multi Meter , Energy Meter, Single / Three Phase , Clamp On Meter , Ammeter Portable Type , Test Lamp , Tong-Tester , Line Tester , Batter Tester , Electrician Tool Kit , Rechargeable Battery , Pressure Transducers Panel Board To Demonstrate Pressure Gauge, Load Cell, Bourdon Tube, Capacitive Transducers. , Flow Transducers Panel Board To Demonstrate Flow Nozzle, Vane Anemometer, Rota Meter. , Temperature Transducers Panel Board To Demonstrate Bimetallic Strip, Rtd, Thermocouple, Thermistor. , Level Transducers Panel Board To Demonstrate Capacitive And Float Switch. , Insulated Screw Diver , Insulated Combination Cutting Plier , Small Screw Driver , C. Tools & Equipment Of Electrical & Sensors , I) Electrical , Digital Multimeter , Variable Resistance Box, Resistors , 9V Dc Battery With Cap , Dual Power Supply , Solder Iron, Solder Lead, Pcb Board (Groove Board), Solder Wick , Inductor , Relay, Led , Function Generator , Bread Board , Synchronous Motor, Capacitor For Synchronous Motor , Power Chord, Connecting Probes, Single Strand & Multi Strand Wires , Ii) Senors , Power Supply , Sensor Kit , D. Mechatronics Lab Outfit , Discrete Component Tester Trainer Kit , Analog Circuit Trainer Kit , Soldering And De Soldering Station , Power Electronic Trainer , Ac Squirrel Cage Induction Motor , Dc Motor Trainer Board. , Auto Transformer , C.R.O , 50 M Hz , Digital And Analog Ic Tester , Digital Tachometer , Signal Generator , Dc Power Supply Unit , Digital Earth Tester , Firefighting Equipment , Linear Ic Trainer Kit , Ac / Dc Motor Speed Control Trainer Kit , Optical Transducer Trainer Kit. , Simple Servomotor Trainer Kit. , Simple Stepper Motor Trainer Kit , Linear Scale Setup For Positional Accuracy Check , A/D And D/A Trainer Kit , Ups , Stabilizer Trainer Kit , Ac Drive , Dc Drive , Digital Circuits Trainer Kit. , 8051 Microcontroller Trainer Board With Led, Switches, Buzzer, Dc Motor And Stepper Motor Interfacing Circuits. , Plc With Io Simulation Panel And Programming Software With Plc Application Module , Ethernet To Profibus Converter , Hmi , Personal Computers , Operating System (Windows Latest Version) , Portable Hard Disk.(1 Tb) , Ms-Office , Rj45,Bnc,D-Shell, Edge Connector Crimping Tool , Megger , Encoder Trainer Kit , Panel Wiring Work Bench , Protection Devices Trainer Board. , Limit Switch, Pressure Switch, Micro Switch, Float Switch, Foot Switch , Application Trainer Kit Of Proximity Sensor, Float Switch, And Reed Switch , Lvdt Trainer Kit. , Actuators Application Trainer(Servo, Stepper Motor, And Solenoid) , Simple Servomotor Trainer Kit. , Simple Stepper Motor Trainer Kit. , Piezoelectric Transducer/Actuator Trainer Kit. , Pneumatic Control Trainer Kit With Required Pneumatic Components. , Hydraulic Control Trainer Kit With Required Hydraulic Components. , Electro-Pneumatic Control Trainer Kit Using Plc With Required Components. , Electro-Hydraulic Control Trainer Kit Using Plc With Required Components. , Linear Scale Setup For Positional Accuracy Check , Plc Based Conveyor System With Pick And Place And Sorting Of Objects (Pneumatic And Hydraulic) , Cut Section Models Of Pneumatic And Hydraulic Motors ,Pumps , Electrical Simulator Software , Electronic Simulator Software , Hydraulics And Pneumatics Simulator Software , E. General Shop Outfit , Sensitive Drilling Machine , Pillar/Column Type Drilling Machine , Power Hacksaw Machine , Double Ended Pedestal Grinder , Ss And Sc Centre Lathe (All Geared) With Minimum Specification As: , Shearing Machine (Lever Type) Hand Operated Complete , Universal Milling Machine , Horizontal And Vertical Milling Machine , Hydraulic Surface Grinding Machine , Universal Cylindrical Grinding Machine , Cnc Turn Centre , Cnc Vertical Machining Centre , Drafting /Autocad Software , Mechanical Parametric Design /Creo (Proe) Software , Simulation Software
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
19.
Educational and Research Institute #10216023 Price Bid
Tender For The Fabrication Of Stalls/Bare Space Using Octonorm System, Installation Of Electrical Fittings, Hiring Of Furniture, Etc.; 1 Stall Size 3mx2m: Fabrication of stall with white octonorm panels, maxima Gate with fascia (1m) along with the top of the podium in the same colour, three side paneling of prefab bright finished octonorm structure connecting table at the back of size 1m x .5m (1 no.), two tables of 1m x 1m on side with ½ x ½ mtr. diagonally cut from the front with floor covering of synthetic needle punch new laminated carpet(**) of good quality with uniform colour, consisting of 6 MS shelves of size 96”x8.5” with 2” depth in front and 3 MS shelves of size 60”x8.5” with 2” depth on one side duly powder coated in the same colour, 5 LED (each of 9 watt), one octonorm table, two black cushion chairs, One dustbin is required to be provided in each stall. Laying and fixing of new laminated synthetic printed ribbed carpet(**) (on hire basis) in all the Halls, which includes passages of Hall No.1,2,3,5 & 6 connecting Authors’ Corners, etc. and complete Foyer Areas inclusive maintenance during the entire period of the fair. 2 Stall Size 2mx2m: Fabrication of stall with white octonorm panels, maxima Gate with fascia (1m) along with the top of the podium in the same colour, three side paneling of prefab bright finished octonorm structure connecting table at the back of size 1m x .5m (1 no.), two tables of 1m x 1m on side with ½ x ½ mtr. diagonally cut from the front with floor covering of synthetic needle punch new laminated carpet(**) of good quality with uniform colour, consisting of 6 MS shelves of size 60”x8.5” with 2”depth duly powder coated in the same colour, 4 LED (each of 9 watt), 1 octonorm table, 2 black cushion chairs, One dustbin is required to be provided in each stall. Laying and fixing of new laminated synthetic printed ribbed carpet(**) (on hire basis) in all the Halls, which includes passages of Hall No.1,2,3,5 & 6 connecting Authors’ Corners, etc. and complete Foyer Areas inclusive maintenance during the entire period of the fair. 3 Bare Space of size 3mx3m: No stalls will be constructed by the Contractor in the Bare space. However, electric connection and laying and fixing of new Brand laminated synthetic printed carpet (**) (on hire basis) to be provided in the entire Halls, which includes passages of Hall No. 2,3,4 5 & 6 and complete Foyer Area inclusive of maintenance during the entire period of the fair. 4 White Octonorm Panels/Walls (1mtr.) with frame (uniform 10 ft. height) 5 Maroon Coloured Octonorm panels/Walls (1mtr.) with frame (uniform 10 ft. height) 6 Maroon Coloured Octonorm Panels/Walls (1mtr.) with frame (8 ft. height) 7 Frame Wall (4 ft.) (1 mtr. x 1 mtr) 8 White Octonorm Panel (4 ft.) (1 mtr. x 1 mtr.) 9 White Octonorm Panel (8 ft. Height) (1 mtr. x 8 ft.) 10 Glass Octonorm Panels/Walls with frame (8 ft. height) along with strips 11 New Brand Steel Almirah (full size) of good quality with proper locking system 12 New Brand Steel Almirah (Small Size) of good quality with proper locking system 13 Stage (Height 9” + Brand New Carpet) (rates per sq. mtr.) 14 Ribbed Carpet (rates per sq. mtr.) 15 New synthetic printed laminated carpet 16 Coir Carpet 17 Green Grass Carpet 18 Green Net 19 Wooden Platform with new laminated Carpeting 20 LED spot Light (9 watt) with fittings for office Block Octonorm Structure and NBT Stalls, etc. 21 Metal LED Light (150 Watt) 22 Metal Light (200 watt) 23 Wireless megaphone-loudspeaker for announcement in public area 24 Parco Light 25 Door with Lock (Standard Size) 26 Door-size curtain 27 LED TV of 55” with proper stand along with provision of connectivity with USB/Laptop for insertion of AV/TV’s sound system 28 LED Wall Screen of Size 8’x12’ with Masking and Ramp (With operator) P5 – Back support connectivity with multi cam setup, connectivity with DVD player/USB and Laptop for insertion for AV’s and TV’s, sound system and stage fold back speakers of 400 watt, sound mixing, console and cables with wires and two power points 29 Complete PA system and Stage set-up for organizing Cultural / Rock Band Programmes with Operator for inaugural function and other programs along with provision of fusion and rock musical band playing for the 9 days during the Book Fair with two helper along with the provision of additional sound & lights as per Tech Rider of Artists (As per the terms & conditions given at Annexure-VI) 30 Box Truss - Length 50’, height 24’, depth and as per stage size (on all four sides) Truss and Scaffolding/Speaker Tower as required 31 Stage Lighting – LED Par Light / Warm White / Moving Head Sharpy Lights / LED Wash Light, Profile Light, Blinder etc. and Controller (Approx. 100 Lights or as perStage requirement 32 FOH Console – Digital Audio Mixer Console 64 channels (Yamaha / A&H / Avid S6L) with laptops and DI Boxes required connecting cables for equipment. 33 Speakers 300–1200 Watt RMS Top speakers/Line Array/Side Fills/subs, Bass (19) Monitor (06) (L-Acoustics, JBL, D&B or equivalent) with Amplifier and other connecting equipments Center-fills (with subs, if required) – as per venue and stage width. 34 Mikes - (10 fixed with stand and 8 cordless microphones, 5 Lapel/ head mic, 2 Podium mic) (Make Sennheiser / Shure/ AKG or equivalent). 35 Bass Guitar and Lead Guitar 36 Drum Riser (size 8 ft.x8x ft.x 1ft. (L x W x H)) 37 LED Screen Wall of Size 40’x10’ or as per requirement with masking & Riser (With operator) P5 – Back support connectivity with multi cam setup, USB connectivity and laptop for insertion for AV’s and TV’s and cables with wires and two power points for relay of Live Program. LED screen should be of the same length as per the stage size in actual 38 Queue Manager (Barricading Post) 39 Iron Barricades (8ft. x 4 ft.) 40 Plug Points (5 Amp) 41 Square Table of size (2’x2’) 42 Round Table: Black Grey Night Marble (Top 4ft.x4ft.) with steel legs (height 30 inches) for SPD Meet. 43 Executive White Chairs for SPD Meet / Rights Table 44 Podium with NBT/NDWBF Logo (3 sides on Digital printing on Sunboard as per design provided by NBT) 45 Octonorm Table (3’x1.5’) 46 Computer Table (2’x1.5’) 47 Centre Glass Table (3’ diametre) 48 Side Table (1.5’) 49 Conference Table (10’x2.5’) 50 Big Table of size (5’x2.5’) 51 Table of size (4’x2.5’) 52 Side Table (1ft height) 53 Flag Poles (Iron) 54 Round Glass Table (2.5ft.x2.5ft.) 55 Table with Drawer and Lock & Key (4’x2’) 56 VIP Office Chair for NBT Officers 57 Revolving Chair for NBT Staff 58 Visitors’ Chairs (White) 59 High Back Chair 60 Executive Sofa Single Seater (Laminated neat and clean sofa set are required to be provided at fair site) 61 Executive Sofa Two Seater (Laminated neat and clean sofa set are required to be provided at fair site) 62 Executive Sofa Three Seater (Laminated neat and clean sofa set are required to be provided at fair site) 63 Pagoda of size 5mtr.x5mtr. with 1ft. raised platform, Brand new laminated carpet with Maxima style Fascia, 2 octonorm tables for Help Desk/Information Counter, 10 visitor chairs (white), Executive two seater sofa set (1 Nos.) (Laminated neat and clean sofa set are required to be provided at fair site), 6 LED lights (each of 9 watts), 1 Dustbin with Lid and handle of 20 Ltr., 2 Plug points, sufficient quantities of curtains for covering up the stall in the night and 1 Metal LED lights (150 watts) - (Exact location of the Pagoda to be informed later on). 64 Pagoda of size 3mtr.x3mtr. with 1ft. raised platform, Brand new laminated carpet, 2 octonorm tables for Help Desk/Information Counter, 4 black cushied chairs, 4 visitors chairs (white), 6 LED lights (each of 9 watts), 1 Dustbin of 20 Ltr. with Lid and handle, 1 Plug point, 1 Metal LED 100 watt Light and 1 small almirah - (Exact location of the Pagoda to be informed later on). 65 Gadda (6’x3’) with Sheet & Cushions 66 Octonorm Gate 67 Maxima Gate with Fascia (1 mtr.) 68 Maxima Style Fascia (2 mtr. x 9.5”) 69 Dustbin – 10 Litre with lid and handle 70 Dustbin – 20 Litre with Lid and handle 71 Dustbin – 50 Litre with Lid and handle 72 Digital Interactive Kiosk for Exhibitors’Information 73 Metal Detector Door size 74 Hand Held Metal Detector 75 Planter Box 76 Wheel Chairs with one support staff for each 77 Complete General PA System with 10 Loudspeakers with 25-40 watt LMP of good quality and 2 Standing Mike (JBL/Sony/Phillips) for Announcement purpose with One Technician & Helper 78 Speakers 100–500 Watt RMS Top speakers (L-Acoustics, JBL, D&B or equivalent) with Amplifier and other connecting equipments 79 Microphones & Cordless Mikes (Make: Shure/AKG/Sennheiser or equivalent) 80 Fabrication of Chairman/Director Office and Protocol Office 81 Translucent Polycarbonate sheet panels, & fixing of black powder coated 10 ft. height Aluminum Maxima Frame with fixtures without etching vinyl sheet (Samples to be shown before executing the job), with ceiling covering of final black net. 82 Toughened glass Doors of 10mm glass with frame & lock (Samples to be shown before executing the job) 83 VIP Executive Tables (size: 5’x2.5’) (Samples to be shown before executing the job) 84 VIP High Back Chairs (Samples to be shown before executing the job) 85 Floor - i) Raised Flooring/ platform of 85 mm/3.30 inch (Laminated new Brand printed carpet(*) onboard corner finish with ‘L’ Shape Aluminum Bidding Angle) with ramp and stairs on both sides. Size-45ft.x60ft. Stage- board (wooden) height of 355 mm/14 inch each, oval or rectangle shape – size (Dais) 30ft.x10ft. (Stage floor English carpet with corner finish (Colour will be informed at the time of work order). 86 Furniture - i) 4 Centre Glass Tables (3’ diametre) or 4 Centre Glass Tables (3’x1.5’), 10 cushioned armed chairs and 2 Podiums with NBT/NDWBF Logo (3 sides on Digital printing on Sunboard as per Image shown at Annexure-VI and as per design provided by NBT) (Furniture should match the floor plan/ visualizations) and 2 Octonorm Tables. 87 Visitor Chairs (White) 88 Backdrop with both side wings (size 4 ft. width x 12 ft.height) on digital vinyl print for Events Corner 89 Backdrop for Author’s Corner (English/Hindi) size of 10ft. (Height) x 30ft. (Width) on digital vinyl print (Two side paneling in Maroon colour is required in new Halls). 90 Lighting requirements – 10 nos. LED lights (18 watt) on 1 self-leglight stand, 1 LED Screen (50 inch) for 9 days — (The bezel 10m with stand and back support connectivity with multi-cam setup, USB connectivity and laptop for insertion for AV’s & TV’s, Sound system & stage fold back speakers, Sound mixing console, cables with wires and 5 Power Points 91 LED Wall Screen of Size 8’x12’ with Masking and Ramp (With operator) P5 – Back support connectivity with multi cam setup, USB connectivity and laptop for insertion for AV’s and TV’s, sound system and stage fold back speakers of 400 watt, sound mixing, console and cables with wires and two power points 92 Flower pots 93 Complete PA system of good/reputed brand like Philips/Sony/JBL with Technician/Operator and Helper 94 Console – Digital Audio Mixer Console 16 channels (Yamaha / A&H / Avid S6L) with laptops and DI Boxes required connecting cables for equipment. 95 Speakers 400–500 Watt RMS Top Speakers & 4 Bass (L-Acoustics, JBL, D&B or equivalent) with 2 monitors, Amplifier and other connecting equipments – as per venue and stage width. 96 Mikes - (8 fixed with stand and 4 cordless microphones, 3 Lapel/ head mic, 1 Podium mic) (Make Sennheiser / Shure/ AKG or equivalent). 97 Stall of size 4mtr.x3mtr. (with Maroon colour paneling) for Officer In-charge — Arrangement of 9 LED Lights of 9 watts, 2 power point (each of 5-15 Amp), 1 executive sofa set (2 seater), 3 executive sofa set (1 seater) – (Laminated neat and clean sofa set are required to be provided at fair site), 6 cushioned armed chairs, 2 curtains, 2 octonorm tables with 1 Glass Centre table, 1 Dustbin and 1 new Almirah (Big).
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
20.
Science and Technology #10213076 Price Bid
Tender For ANNUAL MAINTENANCE CONTRACT Of All Lab Buildings Of Iip.(Electrical Works) 2025-26.-- 1 wiring for light point/ fan point/ exhaust fan point/ call bell point/ with 1.5sqmm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc as required. 2 Group-C 3 Wiring for circuit/submain wiring along with earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduitas required 4 2x1.5 sq mm + 1x1.5 sq mm earth wire 5 2x2.5 sq mm + 1x2.5 sq mm earth wire 6 2x4 sq mm +1x4 sq mm earth wire 7 2x6 sq mm + 1x6 sq mm earth wire 8 4x4 sq mm + 2x4 sq mm earth wire 9 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 10 3 X 1.5 sq mm 11 3 x2.5 sq mm 12 3 x 4 sq mm 13 3 x 6 sq m 14 supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed/ PVC conduit as required. 15 2 pair 16 Supplying and fixing of following sizes of steel conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required. 17 20 mm 18 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required. 19 20 mm 20 25 mm 21 Supplying and fixing metal box of following size (nominal size) on surface or in recessed with suitable size of phenolic laminated sheet cover in front including painting etc as required. 22 100 mmx 100 mmx 60 mm deep 23 180 mmx 100 mmx 60 mm deep 24 200 mmx 125 mmx 60 mm deep 25 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc as required. 26 5/6 amps switch 27 15/ 16 amps switch 28 3 pin 5/6 amps socket oulet 29 6 pin 15/ 16 amps socket oulet 30 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 31 5/6 amps switch 32 15/ 16 amps switch 33 3 pin 5/6 amps socket oulet 34 6 pin 15/ 16 amps socket oulet 35 Telephone socket outlet 36 Supplying and fixingtwo module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required 37 Supplying and fixingfollowing size/ modules, GI box along with modular base & cover plate for modular switch in recess etc as required 38 1 or 2 module (75 mm x 75 mm) 39 3 module (100 mm x 75 mm) 40 6 module (200 mm x 75 mm) 41 8 module (125 mm x 125 mm) 42 12 module (200 mm x 150 mm) 43 Supplying and fixing following metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including providing and fixing 6pin 5A & 15 A socket outlet and 15 A piano type switch, connection, painting etc. as required . 44 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 and 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As required 45 Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connection etc as required 46 Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. 47 Installation,testing and commissioning of pre-wired fluorescent fitting/compact fluorescent fitting of all types,compelete with all accessories and tube etc.directly on ceiling/wall,including connection with 1.5 sq mm FR PVC insulated copper conductor,single core cable and earthing etc. as required. 48 installation, testing and commissioning of ceiling fan, including wiring the down rod of standrand lenght ( up to 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. As required 49 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc as requied upto 450 mm . 50 Extra for fixing the louvers/ Shutters completee with frame for a exhaust fan of all sizes. 51 Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required. 52 1 run of cable 53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 2 Nos. 3 pin 5/6 amp. modular socket outlet and 5/6 amps modular switch with connection etc. As required ( for light plug to be used in Non- Residential buildings) 54 Providing and fixing following rating and breaking capacity MCCB in existing cubical panel board including drilling holes in cubical panel, making connections etc as required 55 200 Amp, 25 KA, TP MCCB 56 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415V TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200A, tinned copper bus bar, common neutral link, earth bar, din bar for mountingMCBs (but without MCBs and incomer) as required 57 12 way, (4 + 36) double door 58 Supplying and fixing 5 amps to 32 amps rating, 240v/ 415v, C curve, miniture circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testingand commissioning etc. As required 59 single pole (Modular Type) 60 Single pole and neutral 61 Double pole 62 Tripple pole 63 Tripple pole and neutral 64 supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required. 65 40 amps 66 63 amps 67 supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetion, testing and commissioning etc. as required. 68 40 amps 69 63 amps 70 Supplying and fixing DP sheet steel enclosure on surface/Recess alongwith 25/32 Amp. 240 volt c curve DP MCB complete with connection, testing, commissioning et. As required. 71 Supplying and fixing TP sheet steel enclosure on surface/Recess alongwith 16/25/32 Amp. 240 volt c curve TP MCB complete with connection, testing, commissioning et. As required. 72 Supplying nd Fixing 20 A, 240V SPN Industrial type socket outlet, with 2 pole and Earth metal enclosed plug top along with 20 A, C curve SP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required. 73 Supplying nd Fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and Earth metal enclosed plug top along with 30 A, C curve TP MCB in sheet steel enclosure, on surface or in recess. With chain metal cover for the socket outlet and complete with connections, testing, commissionimng etc. as required. 74 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing RCC / HUME / METAL pipe etc. As required. 75 upto 35 sq mm 76 Above 35 sq mm and upto 95 sq mm 77 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in existing masonry open duct as required etc. As required. 78 upto 35 sq mm 79 Above 35 sq mm and upto 95 sq mm 80 Laying and fixing of one number PVC inslulated and PVC sheated/ XLPE power cable of 1.1KV grade of following size on wall surface as required. 81 upto 35 sq mm (clamped with 1mm thick saddle) 82 Above 35 sq mm and upto 95 sq mm(clamped with 25x3mm MS flat clamp) 83 Above 95 sq mm and upto 185 sq mm(clamped with 25/40x3mm MS flat clamp) 84 Erection of metalic pole of following length in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) foundtion including exvation and refilling etc. as required. 85 Above 4.5 Meter and uopto 6.5 Meter 86 Providing and making steel pole collar with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregated 40 mm nominal size) of specified size and shape including form work, plastering if required, quring etc. as required. (Volume of pole/ pipe not to be deducted) 87 Supplying and embedding following dia G.I Pipe (medium class) in pole collar/ foundation during casting for cable entry including bending the pipe to the rquired shape complete as required. 88 32 mm dia 89 Supplying and fixing 32/40 mm dia x 2.00 meters long G.I pipe (meidum class) bracket for mounting of fiuorscent/ HPMV/ HPSV street light fitting on pole including bendingshape, 2 nos. 40 mmx 3mm flat iron clamps with nuts, bolts andthe pipe to the require washer, painting the flat iron primer and finish piant etc as required. 90 Dismentaling of pole/ street light standred sturt embedded in cement concrete foundation et. As required. 91 Excavation for cable trenches in soft soil depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soi, refilling with sand or good soil after laying of cable/pipe etc. in layers of 20 cm, ramming watreing and disposal of surplus excavated soil as directed, witinh a lead of 50 meters. 92 Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 93 63 mm dia (OD-63 mm & ID-51 mm nominal) 94 Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology base occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10A, for mounting height up to 2.8 meter and 5 meter diameter coverage area along with necessary fixing arrangements i/c programming at site complete as required. 95 Supplying, installation, testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/ Lighitng DBs for automatic switching On & OFF of street lights at sun set & sun reise or twilight (Auto ON,OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required. 96 1 out put per phase suitable for single phase supply 97 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing et. complete s required. 98 Supply of labour for attending day to day complaints complaints of electrical maintenance work for repair and replacement of all electrical accessories in non workingelectrical fittings and fixture (such main boards, fans, geysers switches, sockets, light fittings, motors, starters, street light, energy meters in lab buildings, underground and overhead line distribution network including service main, operation and maintenance 33KV 044KV substation and power house (24 hour round the clock) all other electrical work as assigned by site-incharge. 99 Skilled labour in Electrical trade 100 Unskilled labour in Electrical trade 101 Attending day to day complaints of no light/ non working points / providing temporary connections in IIP lab buildings, hostel & guest house etc as required. 102 Supplying of RJ45 outlet information module in exsiting modular box etc as required. 103 Supplying of Industrial Heavy duty exhaust fan of 380 mm sweep 1400 rpm/Turboforce neo SP, HD suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 104 Supplying ofexhaust fan of 300 mm sweep 1400 rpm/Ventil air sweep suitable for 230v 50hz ac supply complete with blade, regular, frame and moving system etc as required .The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 105 Supplyingof following size ISI marked PVC insulated and PVC sheathed/XLPE /FRLS aluminium conductor steel armoured alumimium cable of 1.1KV grade as required. 106 2 X 16 sqmm 107 Supplying following rating 415/230v C series, miniture circuit breaker suitable for lighting and other load of following poles in the existing MCB DB complete with connection, testing and commissioning etc as required 108 Double pole, 63 amps 109 Tripple pole and neural, 63 amps 110 Supply and fabrication of sheet steel MCB enclosure fitted with din rail for MCB of following rating complete with connections including drilling holes etc as required. 111 Double pole enclosure 112 Four pole enclosure 113 Supply and replacemant of capacitor of ceiling fans/ exhaust fan/ wall fan/ padestal fan of size of 2.5 to 4 mfd etc as required 114 Supply & replacement of 16 Amp. Plug top, 3 pin with indigator etc. as required 115 Supply & replacement of 6 Amp. Plug top, 3 pin with indigator etc. as required. 116 supply of following Decorative MIRROR LIGHT 20 W with smart, contemporary design of mirror light . The design is a harmonious blend of curves and angles with frame and inbuilt electronic driver & led luminare etc. as required. 117 20W LED, 6500 K luminaries with tube rod. 118 Supplying of following General purpose industrial compact batten suitable for single or twin LED Tube light with integral LED driver, available in single / double side connection options with all as required. Fixture size: (LxWxH) in (1233x36x46) mm (for 1x22 W), (1233x71x46) mm (for 2x22 W) 119 1 X 4 X 22W LED batten 120 2 X 4 X 22W LED batten 121 Supplying of following high efficiency LED tube rod lamps LED luminaire in existing fitting fixture with connection etc. as required. 122 4 X 20W LED luminaries tube rod. 123 supply of indoor recess/ surface 600X600mm (2X2) LED luminaire 36 Watt, 6500 k with high luman package etc as required.The product features special glare cut optics to ensure low luminaire luminance and is perfect for general and office lighting applications such as workstations, meeting rooms and cabins,corridors and break areas.(Havells/ Wipro/ Philiphs/ c&s) The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 124 Supplying of 25 Watt, 6500K new generation LED post of lanturn light luminare IP 65, energy saving, enviornmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium lad scape luminaire with high power LEDs as light souce. Clear cover offers bright illumination for different application. (Havells/ Wipro/ Philiphs/ c&s). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 125 S/R of following Watt LED strret luminaire, New genration energy savin and enviornmental friendly long life LED street light made uo of pressure die cast aluminium housing with high efficiency LED s lighting source and Toughened glass having bottom opening seperate driver compartment with IP 66 protection and impact Resistance of IK07. (Bajaj/ Havells/Philiphs/WIPRO). The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 126 30 W led luminaire 127 Supplying of Surface/Recess Mounting LED Panel fitting fixture 15 W( 1X 1), Elegantly designed sleek recessed mounted pressure die- cast alumium luminaire in powder coated white finish in square profile with optimized heat sink for efficient heat dissipation and indepndent elctronic LED driver with connection all etc as required. The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 128 Supplying and drawing folowing size of PVC insulated Aluminium flat twin core weather proof cabe in existing pipe or surface etc as required. 129 2x6sq mm 130 Supplying of Wall fan of 400 mm sweep, 5 STAR ,energy saving, decorative swing model( off white) suitable for 230 V, single phase, 50 Hz supply including all etc…as required. (Havells/Bajaj/Usha).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 131 Supplying of 50 W turbo LED FLOODLIGHT luminaure, Energy saving, enviornmental friendly, long life, one desig for aesthetic consistancy in multi purpose application with SMD LEDs as light source with driver included, suitable for highliting architectural features or area lighting. also suitable to rough services/ installations.( Bajaj/ Philiphs/Havells/Wipro).The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site. 132 Providing 9 watt retrofit LED bulbs for guest house etc…as required. 133 Supply of GI electrical pole straight pole of overall length upto 6 meter having two steps and dimensions of 80 mm x 60 mm and pole thickness is 3.65 mm x 3.25 mm for fixing street light complete with M.S base plate having 6.00 mm thickness and with one meter welded tubalar bracket for mounting light fixture all etc. as required. (Detailed pole structure will be as per drawing and aproved by Engineer-in-charge before its dispatch from factory to site).
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
Uttarakhand View Result →
22.
Defence #9929205 AOC
Tender For Augmentation Of Power Supply At Naval Area Visakhapatnam.; 1 Schedule A Part – I to Schedule A Part – VII:NOTE: Schedule A Part – I to Part –VII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only 2 Lumpsum price worked out by the contractor for BUILDINGS & STRUCTURES,as listed in Schedule A Part – I 3 Lumpsum price worked out by the contractor for SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION,as listed in Schedule A Part – II 4 Lumpsum price worked out by the contractor for INTERNAL ELECTRIFICATION, as listed in Schedule A Part – III 5 Lumpsum price worked out by the contractor for INTERNAL WATER SUPPLY, as listed in Schedule A Part – IV 6 Lumpsum price worked out by the contractor for SEWAGE DISPOSAL,as listed in Schedule A Part – V 7 Lumpsum price worked out by the contractor for EXTERNAL ELECTRIFICATION, as listed in Schedule A Part – VI 8 Lumpsum price worked out by the contractor for LIGHTENING PROTECTION ,as listed in Schedule A Part – VII 9 Schedule A Part - VIII: (Miscellaneous Items) ( Internal Electrification, Internal water supply, External Electrification, Site clearance & Area development, Lightening Protection and AC & Ref) 10 Internal Electrification 11 M&L for Ponit wiring with 1.5 sqmmPVC insulated and unsheathed copper conductorcable multistranded 1100 Volts grade, FRLS, ISI marked drawn through and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall or surface mounted on pillars/columns including provn of box type switchboard consisting of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets,for mounting modular brackets,with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed forOne light/ exhaust fan/ fanpoint controlled by one switch :-Note: (a) The PVC conduit shall be concealed and switch boards shall be flush to wall. (b) On columns/ pillars the box type switchboards surface mounted with necessary PVC conduit upto ceiling/nearest junction tapping shall be surface type conduitand quoted rate deemed to be inclusive for the same.(c) The quoted rate inclsuive necessary modules any type as per requirement incl all accessories complete 12 All as per item No. 10 abovebut one light point controlled by two Nos of two way switch complete all as specefied and directed. 13 All as per item No.10 above but One3 pin socket outlet 05 amps socket on independent board with 1.5 sqmm FRLS PVC wire for phase and neutral and one run of 1.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 14 All as per item No.10 above but One3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire for phase and neutral and one run of 2.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 15 All as per item No. 10 above but for one geycer/AC point with 4.0 sqmm FRLS PVC wire for phase and neutral and one run of 4 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 16 S&Fexhaust fan, steel body AC single Phase. 230 V of size 450mm sweep with, blades, and frame and louvers fixed on wall making opening, fixing and making good the distrubed surfaces etccomplete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as spcified and as directed. 17 S&FLED tube light fitting, batten type,poly carbonate body, 20Watt fitting with all accessories, internally prewired and connecting up with with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. 18 S&FLED light fitting, batten type,suspended LED aluminium profile lights cool white 36 watt length 1200mm including all connections, hanging strings complete all as specified and directed. 19 S&FLED bay light fitting 70 Watt 230V AC indoor type with thermal management in multiple optics and industrial type and corrosion resistant complete with driver and lamp complete all as specified and directed. 20 S&FLED flood light fitting 210 Watt 230V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 21 S&F LED bldg Security light fitting 35 Watt, 230AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 ptoction complete all accessories including 1.5sqmm weather proof 3 core FRLS grade copper conductor to fitting including 32mm dia medium grade1.5 m long GI pipe for fixing of street lights, bend to shape for fixing on wall/pole withsuitable MS brackets nuts and bolts etccompelte all as specified and as directred. 22 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( for SPN DB to board and submain wiring of building security light)Note :(i) Two run of 2.5 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 23 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) Two run of 4 Sqmm + one run of 4 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 24 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 4x10 sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) four run of 10 Sqmm + one run of 10 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 25 S&F VTPN MCCB DB 4 way 12 outgoing having powder coated sheet steel enclosure fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 26 S&F TPN DB 4 way 12 outgoing having powder coated sheet steel enclosure double door fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 27 M&L for earthing complete with GI steel plate electrode 600x600x6 mm, burried directly in ground (earth pit not less than 2.25 m deep below ground level)with top edge of the plate not less than 1.5 m below normal groundlevel, connected to GI wire 4 mm dia (upto 7.5M in length from earth plate) by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed.Note: GI earth wire upto 7.5 m shall be deemed to be included in the quoted lumpsum and beyond 7.5 m shall be measured and paid separately under relavent item. 28 Internal Water Supply 29 S&F Bib taps two way, cast copper alloy fancy typechromium plated with crutch or butterfly handle, screwed down for size of15 mm inner dia, suitable fo 16 mm outer dia CPVC pipes complete all as specified and as directed. Make:- Jaquar cat No. OPP-15041PM or equivalent 30 SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION 31 M&L for cleaning jungle incl uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm and removal of rubbish upto a distance of 50 m outside the pheiphery of the area cleared all as specified and as directed. 32 External Electrification 33 Supply, Installation, Testing and Commissioning of Copper wound Power transformer step down outdoor type 132/33 KV, capacity16 MVA(suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Star/star (YNyn0) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with terminal arrangement of HV Outdoor Bushings/LV Bushing and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relay & Oil Surge Relayd) NCT on EHV and HV sidee) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Sealingh) Breatherj) Aircell in conservator tankk) Radiators and control valvesl) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomm) motor operated OLTC shall be n) On load tap changing with RTCC panelo) Marshalling boxp) Thermosphyn filter 34 q) Terminal Connectorsr) Direct solid earthing both HV side and LV sides) Name Plate (Rating, Diagram and Valve Plates)t) Metallic enclosed NGR as per OEMu) NIFPS to be installed by OEMTransformer rating plate shall contain the information as given in IS-2026 (Part-I).Makes: Bharat Bijlee/Crompton Greaves / Schneider / Siemens 35 Note : a) PCC foundation and mounting rails, all civil work, etc and general works which are required as per site/technically required to achieve optimum efficency of the transformer are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted.b)Size of plinth, PCC, Rail size etc shall be as per OEM recommendation.c) Technical drgs of the transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch.d) pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.e) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test) 36 f)Full Type Test Reports of at least the followings must be submitted: -1. 132/33 kV Power Transformer for same capacity or higher2. Tap Changer3. Buchholz Relay4. Pressure Relief valve5. Oil Surge Relay6. Temperature rise test7. Impulse test 8. Load and No load loss 37 Supply, install, test and commission lightning arrestor single pole made of polymer , heavy duty station class, gapless, zinc oxide type (non linear) fitted with pressure relief device, arc diverting ports, grading/corona rings, discharge counter with ammeter, mounting insulator complete all as specified and as per IS 3070 (Part I) and with following parameters:- Nominal system voltage : 132 KVNormal discharge current rating : 10 KA .Note- The cost of Galvanised Iron lattice structure including foundation (as Per OEM) is deemed to be included in the Quoted rate 38 Supply, Installation, Testing and Commissioning of cable XLPE insulated, armoured, 132 KV grade (E) copper conductor UG cable, laid in trenches/on structures/in cable duct horizontally or in tier formation as per site condition complete all as per IS specifications of size. 1 C x 630 sqmm. The cable shall be of EHV grade single core, armoured stranded compacted circular Copper conductor of cross section 630 sq.mm, core screening by a layer of semiconducting tape followed by a layer of semiconducting compound, cross linked polyethylene (XLPE) dry cured insulation, insulation screening with semiconducting compound extruded directly over the insulation, longitudinal sealing by a layer of non woven tape with water swellable absorbent over insulation screen, followed by radial sealing of corrugated & seamless or seam welded aluminum with asphalt coating & overall PE sheathed & graphite coated/semi conducting layer and conforming to the technical particulars of specification.IS 7098 part 3 shall be followed for manufacturing of cable along with technical specification. Makes: Universal/ KEI /RPG/CCI.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. 39 Supply, lay, connect, test and commission multi core copper conductor cables, PVC insulated, LT 1100 volts grade GI strip/wire armoured in ducts/on structuresincluding clamps, terminations on both ends with glands and connecting up to the equipment all as specified and of following sizes:- 40 4 core 1.5 sqmm 41 4 core 2.5 sqmm 42 6 core 2.5 sqmm 43 6 core 4 sqmm 44 Supply and fix GI cable tray perforated on walls/MS angle iron supportsof depth 100mm following widths including bends, coupler plates complete all as specified.Note: Angle iron used for fixing cable trays will be measued and paid separately. 45 200 mm width 46 300 mm width 47 Material and labour for provision of earthmat laid in trenches/ ducts/ walls made of following sizes of GI strips including jointing by means of brazing complete all as specified :- 48 GI 100 x 10 mm 49 GI 75 x 10 mm 50 GI 50 x 6 mm 51 GI 32 x 6 mm 52 Supply and fix earth strip following sizes laid in trench/ floor/ walls including jointing by means of brazing complete all as specified :- 53 100 x 10 mm copper strip 54 50 x 6 mm copper strip 55 32 x 6 mm copper strip 56 Supply, installing, testing and commissioning of CPRI approved LT panel board, cubical indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron frame made of 50 x 50 x 6mm at vertical corners & medium channel at base of panel board floor mounted, dust and vermin proof, with busbar 200 Amps suitable for voltage 415 V 3 phase 4 wire weather proof, with separate hinge door for each compartment with locking arrangement, with back door common openable (screwed), groutedin PCC 1:2:4 complete incl painting the steel surfaces with two coats of zinc chromate primer & two coats of epxoy paint suitable for installation in coastal areas and incl of suitable size aluminium busbar (TPN), suitable cable glands, LED Indicating lamps and incl provn of the following:- 57 (i) 4 Pole MCCB 25 KA 100 A - 1 Nos (I/C)(ii) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 03 No (iii) 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (iv) 4 Pole MCCB 25Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (v) Digital voltmeter with selector switch - 1 No (vi) Digital ammeter with CTs & selector switch - 1 No (vii) LED indicating lamps - 8 sets (3 lamps/set) 58 Supply and lay in trenches HDPE pipe Double wall corrugated 200 mm dia with integral socketsfor cable protection including necessary collars, earth work and sealing at both ends with bitumen compound complete all as specified. 59 Supply, lay, connect, test and commission cable LT 1100 volts heavy duty XLPE insulated armoured aluminium conductors, in trenches/ ducts on angle iron supports including glanding, crimping and connecting up complete all as specified and of following sizes:- 60 3.5 Core x 95 sqmm 61 4 Core x 25 sqmm 62 Supply, Installation, Testing and Commissioning Earthing complete with Galvanised Iron plate electrode 600x600x6 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 40 mm dia light grade GI pipe all as specified and directed and tested on completion. 63 Supply, Installation, Testing and Commissioning Earthing complete with copper earth plate electrode 600x600x3 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper earth strip 25 x 3 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 32 mm dia light grade GI pipe all as specified and directed and tested on completion. 64 Boring of holes under road, pavement, hard standing by trenches by trenchless technologyas per site conditions using ultra sound technique and necessary machinery complete all as specified 65 depth of trench varying between 2 to 4 meters 66 depth of trench varying between 4 to 7 meters 67 Supply, Installation, Testing and commissioning ofindoor, metal enclosed corrosion proof aluminium alloy gas insulated switchgear 145 KV 3Phase 50 HZ, 2500 Amps, Three phase encapsulated consisting of2 nos outgoing transformer bay in either side of the existing GIS (Siemens) including installation tools, spares, refill kits all as specified. Makes: ABB/CG/GE/SIEMENS 68 Each Transformer feeder bay consists of the following: 2Nosa) Circuit breaker SF6 insulated 145 KV 2500 A 3 pole with short circuit current with stand capacity of 40 KA for 3 sec - 1 No.b) Disconnector cum earthing switch SF6 insulated, 145 KV 2500 A 3 pole motor operated - 2 sets.1 set on Bus side and 1 set on line side.c) Fast acting earth switch SF6 insulated 145 KV motor operated - 1 sets. d) Current transformer 145 KV 300-150/5+5+5 with Core 1:class 0.2, 15 VA , Core 2 : 5P20, Core 3 : PS class, 15 VA respectively - 1 Set (Three Nos).e) Three phase Voltage transformer 0.2 class accuracy, 10 VA burden,145 KV, 132 KV/√3/110V/√3 - 1 set.f) Lightning arrestor gapless type metal zinc oxide type 120 KV rms 10 KA including discharge counter and leakage current meter.g) Bus bars 145 KV 2500 Amps 3Ø - required as per scheme.h) Cable end box suitable for 132 KV system - 1 No.j) Local control panel- 1 No. 69 Note : The GIS system offered by the bidder shall be designed, manufactured, assembled and tested in accordance with the IEC 62271-203 for switch gear and other relevant IEC andfor balance materials as mentioned in PS. The GIS Outgoing bays are to be installed with the existing GIS extension (Siemens Make ) interface in either sides of the setup. Bidder has to supply the following items along with GIS system and costis deemed to be included in GIS system. Civil foundation / mounting rails, all civil work, etc and general works which if required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. Erection & commissioing shall be under OEM recommendation and supervision. The earth connection from GIS euipment to earth grid/matt as per OEM recomendation and the cost of same is deemed to be included in the unit price. Technical drgs of the GIS module submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the GIS module to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of GIS module shall be carried out by Senior Electrical Inspector / Electrical Inspector. 70 a) Local control cubicles.b) Gas handling equipment for draining and refilling of each compartment of GIS including filtration and purification equipment and vacuum pump. c) SF6 gas sufficient for first filling of entire switch gear including usual losses during commissioning.d)1 Bottles (40 Kg each) of SF6 gas in non returnable vessels. e)Gas leakage detectors.f) Gas Purity Tester for air content and moisture content in SF6 gas. g)Special tool and tackles for erection operation and maintenance of GIS h)Mandatory spares and tools ( Aux contact ( for CB, Busbar disconnector), Motor for CB drive (DS-ES drive), Bursting Disc, Adsorber, Density Monitor for CB, Tripping coil, Closing Coil. - 01 set Each.(i) Bay control unit. 71 Supply, Installation, Testing and Commissioning of control and relay simplex type panel with front swing & front perplex glass door RAL7035 natural IP 32 ventilation for 132/33 KV transformers protection consisting of the following: 72 a) Numerical Transformer Differential Protection Relay Make- ABB/Siemens – 1nob) Numerical Backup Protection Relay of Make - ABB/Siemens – 1noc) Tri Vector Meter - Secure make Premier 300 or Equivalent- with ABT & RS485 (modbus) port, RJ 45 port Accuracy class 0.2S- 2nod) Auxiliary Relay - with self-reset contacts. Operating time<20ms. (4 Contacts) of Make ABB/Siemens – 5nose) DC/ACSupply Supervision-200ms 73 Supply, Installation, Testing and Commissioning of 145KV 630A 40KAOil filled outdoor termination with composite insulator, solid rod connector bolt and support insulators for cables with XLPE insulation. The termination base plate and the cables metallic sheath shall be electrically insulated from the supporting structure by means of self-supporting stand-off insulators or any other self-supporting means designed to withstand both mechanical and electrical stresses in services. The stress cone shall inhibit possible mechanical stress and deformation of the cable insulation surface during operation and also shall be capable of accommodating minor radial and longitudinal movement without determent to the dielectric stress in the insulation shield. The termination shall be within polymeric or porcelain hollow insulator in brown or grey colour as perstandard practice of manufacturing in addition upon, arcing horn and shield ring shall have to be supplied wherever required. The termination shall be filled with an insulating compound up to a level where the electric field is substantially reduced and shall be offered. Oil filled termination should have silicon oil as di-electric medium. Silicon oil should not be subject to any heating at site prior to filling. The outdoor terminal should be suitable for very heavily polluted atmospheric conditions with total creepage distance of 31 mm/ kV and protected creepage distance of not more than 50% of the total Creepage distance. The cable end terminals for terminating the cables shall be fully compatible with the cables to be supplied. Civil foundation / Supporting Strcuture etc and general works which are required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. 74 Supply, Installation, Testing and Commissioning of 145kV Dry type GIS termination suitable for XLPE 132 KV IC x 630 sqmm including necessary accessories , fixtures and fittings of complete installation etc complete all a specified and directed.Indoor Termination at GIS SF6 Housing It shall be dry type without insulating oil. There shall be mechanical devices to maintain the interface pressure if requires. It shall be based on the EPR (Ethylene-Propylene Rubber)- based or silicon based stress relief cone. Termination shall be dry type without insulating oil. Stress relief cone and mechanical devices shall be designed to fit with controlled interference over the cable insulation and shall follow the cables diameter variations still guaranteeing under any service condition a sufficient positive pressure to control the electric field concentration. Plug-in type leading conductors shall be supplied though at the time of detailed engineering confirmation shall be given for selection of normal type, blind type or plug-in type. Design and scope of delivery shall be fully complying with IEC-60859, IEC-62271-209 and possibly adjusted the various needs of project. The main insulation components shall be fully examined and tested in the factory.For cable Termination purpose only certified (certification from cable accessories manufacturer ) personnel shall be employed. Make: Raychem or Equivalent 75 Supply, Installation, testing & commissioning ofHT 33KV VCB line up of Six panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 3Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 76 A. INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories :-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5 A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out TypeResin cast Ratio : 33KV/√3/110V/√350VA, CLASS: 0.5-3 Nos.f.12 Window Annunciatorg.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 87C (differential P) and 64 (Restricted earth fault) .Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 77 B. OUTGOING - 3 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motorb.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core-3 : PS class- 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 64 (Restricted earth fault).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 78 C. BUS COUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay with all protection.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 79 Supply, Installation, Testing and Commissioning of Three Phase 4Wire 110V/50A FCBC Thristor based with in-built DCDB and RS485 communicationsuitable for 110V/200AH VRLA battery with 55 Cellsin complete as specified and directed. Make: Amararaja/Exide 80 Supply, installation, testing and commissioning of cable 3 Core 300 Sq.mm 33KV(E) XLPE cable grade cable of size suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, as amended upto date with ISI marked of following sizes in VCV manufacturing process.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch 81 S&F of Cable jointing kit for 33 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm 3 core complete all as specified and directed. 82 S&F of Cable jointing kit for3 Core 300 Sq.mm 33 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 83 S&F of Cable jointing kit for 3 Core 300 Sq.mm 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 84 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of following sizes in VCV manufacturing process. 85 3 Core 240 Sq.mm 86 3 Core 400 Sq.mm 87 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded copper conductor 1 core 1000 sqmm shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of VCV manufacturing process. 88 S&F for Cable jointing kit for 11 KV grade cable for Outdoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 89 S&F for Cable jointing kit for 11 KV grade cable for Indoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 90 S&F for Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm etc complete all as specified and directed. 91 S&F of Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes etc. complete all as specified and directed. 92 3 Core 240 Sq.mm 93 3 Core 400 Sq.mm 94 Design, Supply, Installation, Testing and Commissioning of GSM based energy management system/ substation automation system with suitable software capable of taking care of complete data monitoring, data logging and control functions at 132 MRS consisting of 2 Nos 132 KV GIS, 6 Nos HT 33 KV VCBs at MRS , 7 Nos 33 KV VCBs at NSB Substation, 8 Nos 11 KV VCBs at NSB and other allied switchgears at 33/11 KV substation at DH complete with servers, work stations, desk top computers, operating system, communication products and object softwares assembled from industry standard products all as specified 95 a) BCU suitable for substation automation.b) Integration with Existing Scada server.c) Fibre/Eithernet switch (for station level & bay level) -8 sets.d) RTU (with redundant RTU , Power Supply & Hot Swappable IO configuration) - 2 set.e) SCADA software.f) Suitable Modems & ALUs.h) Integration with Existing central SCADA software- 1 set.Note- a) The SCADA system is GSM based and to be integrated with existing SCADA server. b) The cost of Connecting cable (e.g-Optical fibre cable Network, CAT 6 cable Armoured/unarmoured etc) and accessories for integration of IED, Ethernet and RTU, ALU, IED (Relay) as required at site is deemed to be included in the unit price. c) Technical drgs of the SCADA submitted by the contractor is required to be approved by the accepting officer before taking procurement action . 96 Supply and fixing in position Retardant/ extinguishing electric insulated synthetic mat2.5 mm (+/-) 10% thick conforming to BIS -DOC No ET-02 (540) dt 30/04/2004, meeting requirements of IS- 3043, IS-5216 (Part-1, 2 & 3), IS-15652:2006 and IEC 479 Pub-I tested having minimum width of 1000 mm (+/-) 20 mm. All allied materials such as PU-Resin Chemical bond (hardener), special PVC adhesive liquid primer and qty required to complete the job as per site requirement suitable for all voltages not exceeding 33/11 KV system complete all as specified. 97 M&L for RCC cable route indicator semi-circular shape on top of size 600x450x100 mm casted in PCC 1:3:6with TMT bar of size 10 mm dia and foundation base casted in RCC 1:2:4, grouted in earth upto 550 mm duly engraved the following letters HT UG CABLEwith two coats of antifungal weather coat paint, etc all as specified and directed. 98 S & F for Display chart (set of 2 nos) of size 6 x 4 duly made on white polyvinyl sheet exactly showing the locations of the yard and the machineries and equipments installed in the sub-station duly marked properly with legends etc, and a separate chart showing the details of machineries installed with nos, capacity/ rating and make with computer cutting letters of approved size on poly vinyl sheet all as specified and directed. 99 S&F for Display chart (set of 2 nos) of size 4 x 5 duly made on white polyvinyl sheet exactly showing the lay out of transmission and distribution of HT UG cable routes, locations of the HT Joints, drawn on autocad, etc duly marked properly with legends, with computer cutting letters of approved size on poly vinyl sheet, all as specified and directed. 100 S & F for shock treatment chartof size 1.5 m x 1.5 m x 0.025 m duly laminated with wooden frame (tick wood)enclosure all as specified and fixed in position as directed by Engineer-in-charge. 101 S & F First aid GI box containing prescribed medicines for first aid box as per standard quality and quantity each as required to provide first aid treatment in an emergency complete all as specified 102 Supply, Installation, Testing and Commissioning of Power transformer step down outdoor type 33/11 KV, capacity 16 MVA (suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Delta/star (Dyn11) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with HV/LV Cable Box and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relayd) Oil Surge Relaye) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Preservation Equipment likeh) Oil Sealingj) Breatherk) Aircell in conservator tankl) Radiators and control valvesm) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomn) motor operated OLTC shall be o) On load tap changing with RTCC panelp) Marshalling boxq) Thermosphyn filterr) NIFPS to be installed By OEM 103 Note- i) Technical drgs of the Transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.ii) The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform of transformer as per OEM recommendations and finishing the top surface even and smooth.iii) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test.iv) Type test reports of33/11 KV Transformer of same capacity or higher Such as Temperature rise, Impulse test, Short circuit test , Vacuum Tests of Tank & Radiator, No Load & Load Loss test and tap changer to be submitted by the bidder during Drawing approval 104 Supplying, Installing, Connecting, Commissioning and Testing of Transformer, Step Down, Outdoor Type, Floor or Platform Mounted complete with standard fittings, 33 KV / 433 V [at No load], AC, 3 Phase, 50 Hz, of 100 KVA capacity, Double Copper Wound, K class Natural Ester Oil immersed, CRGO Core type Naturally cooled, Built-up with class A insulation, having Primary Voltage [HT] 33 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 33 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180-2014, including PCC / Brick Masonry Foundation / Platform as per IE Rules, fixing HT / LT Busbar and Cables etc. complete all as specified and as directed andcomprising of the following Specification and Fittings:Continuous Rating: 100 KVANo-Load Voltage Ratio : 33 KV / 433 V Tapping on HV[%]: ± 7.5, ± 5, ± 2.5Phase & Frequency : 3 Phase & 50 HzConnection: Delta StarVector Group : DYN 11Cooling : KNANType: OutdoorNote: The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform as per OEM recommendations and finishing the top surface even and smooth complete all as per manufacturer’s recommendations, as specified and as directed. 105 Fittings:[a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device.[b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug[c] Undercarriage with four plain rollers[d] Oil filling hole cum air release plug[e] Drain Valve cum Sampling Valve[f] Top Filter Valve with Plug[g] Rating Plate with Diagram Plate[h] Lifting lugs for Transformer[j] Lifting lugs for Core[k] Earthing Terminals[l] Thermometer Pockets[m] Silica Gel Breather[n] Explosion Vent[o] Marshalling Box with Double Window[p] OCTC.Note- Technical drgs of the Transformer submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector. 106 Supply, Installation, testing & commissioning ofHT 33KV VCB line up Seven panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 4Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 107 A INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories .a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5 Core-1: 15VA Class 0.5, Core -2 5P20 - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 33KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS) and 64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 108 B. OUTGOING - 4 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Transformer Differential Protecton (except Stn Transformer )64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 109 C. BUSCOUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation.Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 110 Supply, Installation, testing & commissioning ofHT 11KV, 25 kA, VCB line of Nine panels switchboard consisting of 1250 Amps, VCB 11 KV - 02 Nos as Incomer, Bus coupler 1250Amps VCB 11 KV -1Nos , Outoing 1250AVCB 11 KV- 6 Nos.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. The switchgear panel shall be of sheet steel constructionnot less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall totally dust and vermin proof. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2, C2duty. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete Make: ABB /CG / Schneider / Siemens. 111 A. INCOMER-2 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories:-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 800-600-400/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 11KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,l. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 112 B. OUTGOING - 6 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-300-200/5-5A Core-1: 15VA Class 0.5, Core -2 5P20 - 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 113 C. BUSCOUPLER- 1 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking, ABT scheme with Manual option.Note: The above said panelsEarthing truck -02 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panelto be inspected by rep of the accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panelshall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 114 Supply, install, test and commission of APFC panel indoor type 1500 KVAR 12.1 KV, complete Make : CG / Shreem /Siemens /BCH.Capacitor panel consisting of below:-83.33 KVAR, 6.98 KV, externally fused capacitor unit for 250K @12.1KV (207K 11KV) step - 12nos.166.67 KVAR, 6.98 KV, externally fused capacitor unit for 500K @12.11 KV (413K 11KV) step - 3nos.11 KV, Air core dry type, class F aluminium wound, 1Ph, 0.2%, series reactor (STC shall be 16.6 times rated current for 2 sec) - 15nos.11KV, 400A, 10KA for 1 Sec, 3 phase vacuum contactor - 15nos.11 KV/110V-190V, 50-50VA, 3Ф resin cast RVT - 1no.11 KV HT HRC fuses of suitable current rating- 15nos.11 KV, 630Amp, 25KA for 1 sec, off load type isolator- 1no.3PH, RC surge suppressor- 1no.APFC relay (RS485/232 communication port)- 1no.Control cable, space heater, timer, thermostat, CFL lamp, LED indication, push button, selector switch, terminal connectors, gasket, limit switch, name plate, hardware - 1 set. 115 S& F spring loaded aluminium clamps suitable for HV & EHV cables of following sizes inculding all necessary items to fix such as nuts, bolts, washers etc. and all fixing arrangements as required at site. 116 Single core 630 Sqmm 132 KV Al cable 117 Three core 300 Sqmm 33 KV Al cable 118 M & L for survey, site inspection, layout design and location identification for complete earthing/earth mat layouting for best result depending on the soil condition at the site of 132KV and 33 KV yard all complete as specified and directed. Survey report alongwith layout drawing in A3 size properly verified by a Engineer to be submitted in triplicate for approval of Engr in charge/GE 119 Material and labour for brick massonary in cement mortar 1:4 of internal size 1000 x 1000 x 800mm for man hole in contol/power cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 120 Material and labour for brick massonary in cement mortar 1:4 of internal size 1500 x 1500 x 1400mm for man hole in control cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 121 M&L for Providing precastreinforced cement concrete slabs 12.5 cm thick M-30 including reinforcementand 12 mm dia MS handle (with plain or interlocking joints as directed setting in mortar 1:6 of size of slab 1.20x1.20M. 122 LIGHTENING PROTECTION 123 M & L for single pointed Air termination Aluminium Rod 12 mm dia 500 mm long with Aluminium base plate of size 125 x 125 x 10mm fixed over hylam sheet of size 175 x 175 x 10mm and fixed on 1.5 Meter GI pipe 25mm Medium grade on roof all specified and as directed. 124 M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge.Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia medium grade GIwater pipe including GI protection pipe 40mm dia light grade for earth strip etc., 2. The cost of earth pit is deemed to be included in the unit rate. 125 AC & REF 126 Supply and install split AC units indoor/outdoorof capacity 2 TR, 3 star , Inverter type, single phase complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condenser complete all as specified and directed 127 S& F Voltage Stabiliser 5 KVA, operating voltage range 130-290 Volt, Single phase complete all as specified and directed. 128 SCHEDULE A PART-IXPHASE -II Outsourcing for sub station for the First 11 Monthsduring Defect Liability Period . 129 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 130 One skilled operator in each shift 131 One semi skilled operator in each shift 132 SCHEDULE A PART-XPHASE -III Outsourcing for sub station for the Second 11 Monthsduring Defect Liability Period . 133 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 134 One skilled operator in each shift 135 One semi skilled operator in each shift 136 SCHEDULE A PART-XIPHASE -IV Outsourcing for sub station for the balance 02 Months after 22 months during Defect Liability Period . 137 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 138 One skilled operator in each shift 139 One semi skilled operator in each shift 140 Note for Item No. 127 to 138:-The rate shall include the following[i] For operation of all out door and indoor structures in the same area.[ii] Contractor shall laise with Dolphin hill sub station in case of major breakdown for early restoration of supply.[iii] In case any problem occurs which seems not under thecontrol of the operator, the same shall be immediately intimated to JE/ AGE E/M.[iv] Any additional man power required for early restoration of supply in case of emergency shall be provided by the contractor.[v] The contractor shall abide by the latest labour rules and minimum wages Act. Wages paid by the contractor to the emplopyed persons shall not be less than minimum wages fixed by the state/ central Govt from time to time whichever is higher.[vi] The contractor shall also insure the workmen employed on th job.[vii] The contractor is responsible for insurance, EPF, ESI, labour welfare cess etc., as applicable and shall be paid to the workmen as per existing Rules/ Acts/ regulations etc., and quoted is deemed to include the same. 141 SCHEDULE A PART-XIIPHASE -VOutsourcing for SCADA system for the First Year after Defect Liability Period . 142 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 143 SCHEDULE A PART-XIIIPHASE -VIOutsourcing for SCADA system for the Second Year after Defect Liability Period . 144 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 145 SCHEDULE A PART-XIVPHASE -VIIOutsourcing for SCADA system for the Third Year after Defect Liability Period . 146 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 147 SCHEDULE A PART-XVPHASE -VIIIOutsourcing for SCADA system for the Fourth Year after Defect Liability Period . 148 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 149 SCHEDULE A PART-XVIPHASE -IXOutsourcing for SCADA system for the Fifth year after Defect Liability Period . 150 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 151 SCHEDULE A PART-XVIIPHASE -XOutsourcing for SCADA system for the Sixth year after Defect Liability Period . 152 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 153 SCHEDULE A PART-XVIIIPHASE -XIOutsourcing for SCADA system for the Seventh year after Defect Liability Period . 154 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 155 SCHEDULE A PART-XIXPHASE -XIIOutsourcing for SCADA system for the Eighth year after Defect Liability Period . 156 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 157 Note for Item No. 140 to 155 [i] Cost of all minor spares/ components including OFC cables, Ethernet switches, connectors etc., is deemed to be included in quoted rate and any type of extra charge will not be made by Dept.[ii] All major defective spares shall be replaced by contractor on exchange basis which is deemed to be included in the unit price.[iii] All periodical tests of all safety devices in accordance with relavant safety standards with full oad testing will be borne by the contractor.[iv] Systematically examine & repair all the components such as software, monitors, servers etc., if any defect found,[v] All required special tools to be arranged by the contractor.[vi] Contractor shall be responsible for maintaining adequate lighting, cooling and moisture control, ventilation as required all at site complete.[vii] All safety measures/ directions and required tests for safety devices annually shall be borne by contractor.[viii] All periodical visits and all breakdown calls related to stoppage, malfunction, special services should be attended compulsory during all days including sundays & holidays.[ix] The contractor shall be liable to pay the telecom bill provided by the service provider.
Contract Date: Jan 06, 2026 Contract Value : 23.55 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Andhra Pradesh View Result →
23.
Power #9921536 AOC
Tender For Material Supply, Spares & Special Tools - RGC - Construction of 33/110kV Step Up GIS at Pushpakandam-- 1 Design, Engineering, Manufacture, Testing at manufacturers works, Delivery at site including all materials, accessories such as OLTC,RTCC, with Transformer Oil and 10% extra Oil, spares,Gaskets, OTI,WTI,MOLG indicators with transducers and Tools as per specification , loading and unloading, transportation, handling, proper storage at siteThree Phase Two Winding Transformer33/110kV, 60MVA Capacity with optical sensors and Remote Data Transfer facility with optical communication media, and all other accessories complete, with SAS Integration Scope , all required valves and flanges for NIFPS shall be provided for transformer at the time of transformer design itself,inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 2 Design, Manufacture, Testing at Manufacturers works, Transportation and Delivery of 110 kV, 3 Phase Encapsulated Double Busbar Indoor Gas Insulated Switchgearequipmentand other accessories at Substation siteand as per respective Technical Specifications, Single Line Diagram, General Arrangement Drawings, IS/IEC standards, approval of KSEBLand relevant special conditions applicable. The quote for each bay shall include necessary interconnecting GI bus ducts within the building. The supply include all accessories of GIS bay, earthing materials for forming the earth grid inside the GIS hallas per standards of GIS earthing (Cu/Al), including RF Earthing, Cable tray, control cable from GIS to LCC, LCC panel, ladder etc. complete. 3 110 kV GIS Feeder Bay with PT(40kA/ 1250A min) 4 110kV GIS Double Bus bar arragement with PT(40kA/ 2500A min) 5 110kV GIS Bus Coupler Bay(40kA/2500A min) 6 110kV GIS Transformer Bay (40kA/1250A min) 7 Polymer housedSurge Arrester suitable for 110kV, 10kA, Class 3 withclamps, terminal connectors suitable for connection of any type of conductor or Al/cu pipe bus as per requirement, leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete 8 110kV composite solid core station post insulator , clamps, connectors etc suitablefor Al/ Cu Pipe Bus /Conductors. 9 Neutral CT (NCT) 36kV 3150Afor 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 1200-600/1-1 Amps(33 kV side) 10 Neutral CT (NCT) 36kV 3150A for 60 MVA 110/33kV, Power Transformer with structure including clamps,terminal connectors and 36kV composite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete-Ratio 400-200/1-1 Amps(110 kV side) 11 UG power cable- 110kV, Single core, 630sqmm, Aluminium conductor,XLPE insulated,Aluminium Corrugated sheathedandHDPE Outer jacket under ground cable having rated short circuit capacity for both conductor and armourwith necessary Non - Magnetic , Metalic Trefoil/flat formation clamps atminimum 3 metre interval, steel/nylon cable ties wherever necessary 12 Outdoor termination kit suitable for 110kV, 630 Sqmm Single core Copper/ Aluminium UG cable for yard structure mountinginclusive of all accessories like earthing cable, suitable Non - Magnetic, Metalic clamp for fixing cable to support structure etc at 1m interval complete. 13 Indoor Plug in Type GIS termination kit for 110kV 630 Sqmm XLPE Single coreCopper/ Aluminium UG cable,inclusive of all accessories like earthing cable, suitable Non - Magnetic , Metalic clamp for fixing cable to support structure etc at 1m interval complete. 14 Supply of 4IPS Schedule 40 Al. Tube including requiredJointing Sleeves, Expansion joints, etc. withnecessary fixing clamp and all accessories complete for 110kV,33kV equipment to equipment connection 15 Three Phase Link Box 6.6kV withoutSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 16 Three Phase Link Box 6.6kV withSVL for 110kV cable with copper bonding cable(minimum cross-section 300sq.mm) including all accessories 17 33kV Indoor composite VCBPanels having bus capacity 31.5 kA for 3sec, 3150A at STC continuous rating, 4 nos feeder bays having capacity not less than 1250A ,2 nos transformer feeder bays (for 33/110kV transformer) having capacity not less than 2000A ,1 nos transformer feeder bay ( for 33/11 kV5MVA Transformer ) having capacity not less than 1250A and1 nos bus coupler with bussection panel not less than 3150A, two bus PT panel at both side of the bus .Every feeder/incomer/ bus coupler shall have CT, E/S, synchro check, SEM Energy Meter, Ammeter, Voltmeter, Control and Protectionincluding earthing as per standards(Cu), cable tray, control cables etc completeand as per SLDand specifications. 33/110 kV 60 MVA Transformer feeder shall have provision for termination of cable size 3 runs per phase of 630 sqmm Aluminium cable. Each incomer panel (transformer) shall be provided with additional special protection class CT cores for differential protection scheme M1 and M2 at 110kV transformer C&R panel. All the feeders shall be remote controlled from SCMS and from the local console of the numerical relays with Bay Control Unit and protection unit including supply of the same. The supply includes one number VCBfor each ratings as spare (2000A, 1250A) and two numbers of service trolley for VCB , E/S, PT and spares (as per attached list clause 6.6 & 6.7 of volume 2, Chapter 27). 18 Polymer housedSurge Arrester suitable for 33kV, 10kA, Class-3 with clamps, terminal connectors etc. suitable for connection ofany type of conductor or Al /Cu pipe bus as per requirement, including leakage current measuring meter with counter, flexible copper cable of required size and all accessories complete (33kV Feeder/ Transformer) 19 33kV 800A Triple Pole Line Isolator with Structure, clamps, terminal connectors etc. suitable for connection of any type of conductor or Al/Cu pipe bus as per requirement 20 33kV Pin insulator with pin 21 33kV composite solid core station post insulator with high level structure with clamp & connectors suitable for Al pipe/conductor. 22 UG power cable- 33kV 1Cx630sqmm Aluminium 33kV, XLPE Aluminium armoured having rated short circuit current capacity for both conductor and armour and HDPE outer jacket for 33/110kV 60MVA transformer incomer with necessary Non-magnetic, metallic, Trefoil/flat formation clamps at minimum 3 metre interval and steel/nylon cable tie wherever necessary 23 Outdoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core Aluminium UG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 24 Indoor Heat shrinkable termination kit suitable for 33kV, 630 Sqmm XLPE Single core AluminiumUG cablewith necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesincluding cost of bimetallic strip etc. and suitable Non-magnetic, metallic clamps for fixing cable to support structure at 1m interval complete. 25 Design, Engineering, manufacturing, testing at Manufactures worksite, supply, delivery,loading and unloading, transportation, handling, proper storage at site,supervisionof erection, testing and commissioning of 33/11kV, 5MVA three phase two windingtransformer as per technical speciationsincluding all materials, accessories such as Off Load Tap Changer, Transformer Oil and 10% extra Oil, spare Gaskets, OTI,WTI,MOLG indicators with transducers as per specification and Remote Data Transfer facility with optical communication media, with SAS Integration Scope , inclusive of necessary connectors/clamps suitable for Aluminium tube/ACSR conductor(All other items as per technical specification / Layout drawings) - intended for Renewable Energy Evacuation 26 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 200/1-1 Amps (33kV side) 27 Neutral CT (NCT) for 5 MVA 33/11kV Power Transformer with structure including clamps,terminal connectors andcomposite solid core post insulator with structure for support of GI earthing conductor/strip with terminal connector and all other accessories complete -Ratio 300/1-1 Amps (11kV side) 28 Alumimium UG Cable- 33kV, 3Cx300 sq.mm XLPE insulated, Galvanised steel strips armoured power cable for feeders / Aux Tfr with necessarymetallic, non magnetic clamps atminimum 3 metre interval, steel/nylon cable tie wherever necessary 29 Outdoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPE Galvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 30 Indoor Termination kit Heat Shrinkable Type for 3Cx300sqmm Aluminium 33kV, XLPEGalvanised steel strips armoured power cable with necessary clamps, connectors suitable for connection ofany type of conductor or Al /Cu pipe buswith all accessoriesetc. and suitable clamps for fixing cable to support structure at 1m interval complete 31 Distribution Transformer 11kV/433V, 250 kVA, Star rated (BEE Latest notification as on date of tender)with 11kV & 433V outdoor cable entry box, suitableDistribution Box with LT cable (Trfr to LT box) with 500Amps Fuse and MCCB including all accessories like Busbar, Metering Cabinets etcand its fixing -mounting arrangement on plinth 32 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches and one Vacuum/SF6 breaker suitable for 11KV/433V Auxillary Transformer/ Outgoing feederas per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 33 11kV Outdoor type RMU withcombination of 2( two) numbers ofSF6 insulated/arc quenching motorized Load Break Switches as per the KSEBL approved make with CT, VT, Control and Protection Relays - Overcurrent/REF etc. and Metering, Indications complete (SCADA compatable) as per the technical specification 34 Supply of 11kV indoor VCB 5 panel set with combinations of Incomer feeder panel with PT (1 number), Outgoing feeder panel (3 number) and transfomer panel (1 number) with bay control and protection unit (BCPU) for integration with upstream Substation Automation System (SAS) through HSR/PRP topology (IEC 61850 edt 2 compliant) with protection philosophy specified in technical specification along with supply of accessories necessary for operational spares and special tools (as per attached list clause 37.6 & 38 of volume 2, Chapter 30). Bus Bar ratings are 2000A. Circuit breaker shall be E2 M2 C2 class as per IEC 62271-200. Feeder, transformer and incomer panel shall have capacitive voltage indicators (CVI) and only incomer panel BPCU will have PT inputs. Feeder,transfomrer and incomer panels shall house one each multi-function meter (MFM) and DLMS compatible energy meters. Each Incoming and outgoing feeders shall be equipped with split core type CBCT for Sensitive Earth Fault Protection 35 Supply of Polymeric type LA suitable for 11kV 36 3Cx300sqmm 11kV Aluminium XLPE insulated under ground armoured cable, with necessaryclamps for fixing with support structure at 3 m interval 37 3Cx300sqmm11kV Aluminium XLPE Under ground cable Termination Kit Outdoor Heat Shrinkable 38 3Cx300mm2 11kV Aluminium XLPE Under ground cable Termination Kit Indoor Heat Shrinkable 39 Supply of Hot dip Galvanised LatticeStructurefor 33kV,11kV& 110 kV Switch Yard, Columns/Beams/Pre fabricated Cable Supports in Trenches/lightning mast structure/ lighting mast structure/ equipment structures unless otherwise not specified else where in the BOQ etcinclusive of N&Betc(as per respective Technical Specifications, standards and relevant special conditions). 40 EOT Crane of suitable capacity (minimum 5T safe working load) with single hook and double girder arrangement for GIS Hall. Contractor shall submit the capacity calculation of the crane incorporating 25% additional load considering erection and maintenance of largest GIS component / assembly. 41 DG set 125 kVA silent type, Outdoor plinth mounted withAMF panel, Auto Load Change over module and panels, Battery and its charger, Diesel Tank etc with SAS integration facilities including all accessories complete 42 Battery Set - 110 V, 400Ah , Lead Acid plante Battery SetC10 Duty cycle (Rating is tentative and final sizing as per the load calculation shall be under bidder scope) & Installationwith Battery Racks made with acid proof material ,two number of indsutrial type flame proof exhaust fan and all necessary arrangements including tool kit like hydro meter, chemical gloves, multimeter etc. 43 48V, 200 AH VRLA Battery Set with all associated accessories for reliable communication & data acquistion project complete as per specifications 44 SCADA compatible 110V Dual mode (FC+ BC) Battery Charger, with independent Float (FC)and Boost charging (BC) (2 number rectifier unit) min-FC-80A, BC-80A, suitable for 110V Battery bank as per design and shall charge Battery set as per technical requirement during float /boost mode without interruption to load. The charger shall have two independent incomer supply.(Battery charger shall meet the full DC load during boost condition and the Bidder shall propose the final sizing of the battery charger during detailed engineering for approval)(Both set shall be of different make ) 45 Battery Charger - 48 V Dual mode (FC+BC) (Float - 30A/Boost - 60A) - SCADA compatible, SMPS based,Suitable to VRLA Battery set and shall be able to charge Battery set as per requirement during float /boost mode as well as it shall supply to load as per rated voltage of load components inclusive of necessary power, communication and control cables with all accessories complete -Compact type 46 SCADA compatible DCDB-110 V with minimum 20 + 20 Outgoing feeders duplex type (Floor Mountable) with changeover panel having interlock facility with 20% spare feeder breakers for station control and protection systems as per the station requirement, facility shall be there to charge any battery set with any of the battery chargerwith interlock. Ratings shall be as per the battery sizing calculation. 47 DCDB 48 V with change over facility and min 20 Nos. of Distribution Outlets( 2 Nos.- 10A and 18 Nos. 6A)-DUPLEX Type-SCADA/SAS Compatible-Wall mountable 48 SCADA compatible LT 3 phase 50Hz Panel Boardwith Insulated Aluminium Bus Bar, 2 nos incomers (Auxillary Transformer / DG Set), automatic interlock/load change over facilty, two sets of outgoing,panel with LED indications, panel meters,ACB /MCCB(incomers), MCCB (feeders), Earth Bus bar etc., for LT Power Distribution to Control room/equipments including all accessories complete as perspecifications having minimum 20% spare feeders.Remote operation shall be possible for incomers and DG set.(Panel sizing and rating to be proposed by the bidder during detailed engineering for approval). 49 SCADA compatible LT MLDB/LDB/Street light control DB with Lighting Transformer, Surge Protection Devices, MCCB, MCB, RCCB, ELCB and all accessories complete as per technical specifications for Control Room and Yard lighting including all sub distribution boards, and SCADA compatible ACDB/Sub ACDB for Air Conditioners & AHU with soft starting feature etc. including MCCB, MCB, RCCB, ELCB. (The DB sizing and rating shall be proposed by the bidder, with 20% spare capacity, during detailed engineering for KSEBL approval) 50 SCADA compatible LT Emegency Lighting Distribution Board (ELDB) with 63A Incomer and minimum 12Nos 10A Outgoing Feeders and DC Emegency Lighting Distribution Board (DC ELDB) and related accessories including MCCB/MCB,RCCB/ ELCB as perstandard specifications for Emergency lighting in the substation / Switchyard, charges including all sub distribution boards 51 LT A.C Three Phase Self mounted Indoor Power Kiosk IP 42 with 1 incomer MCCB 63A including indicating lamps,single phase and three phaseindustrial type16A sockets etc. at GIS hall 52 LT A.C Three Phase Self mounted Outdoor Power Kiosk (IP 56) with 1 incomer MCCB 250A, 2 Outgoing MCCB 160A & 100A including indicating lamps,3 phase and singlephase industrial type 16A sockets etc. complete for Transformer oil filteration unit, welding purpose etc. 53 Supply of Protection Panels/Equipments, Substation Automation System and materials as per technical specifications, IS/IEC Standards applicable 54 Control and Protection panel for Transformer with Differential Protection,REF (Transformer management relay) for HV and LV [M1 and M2 relay shall be of different make / platform and each shall have-87, 67/67N, 64R-Low Impedance, Transformer Mechanical Protection- Bucholz, OLTC Bucholz, OLTCPanel Control & signal interfacing with RTCC panel, OTI, WTI, PRD1 &2 through high impedance tripping relays, MOLG Alarms etc.,] 33/110kV 60MVA, with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA system. Energy meters as per technical specifications and suitable for GIS switchgear modules 55 Busbar Protection panel for8 bays (110kV Bus) as per specifications -with zone segregated tripping, LBB, end zone protection, local HMI for displaying differential current, SLD, Isolator Position etc., with output tripping relays (drawout type) and provision for interface to SCADA/SAS system 56 Control and Protection panels (main 1 and 2- 87L,21,67/67N,50N,59,PSB, 79A/R,49,81 O/U) for 110kV Feeders with BCU , IEC 61850 Edition 2compatible and provision for interface to SCADA systemas per tech specifications and suitable for GIS switchgear modules (M1 and M2 relay shall be of different make / platform and the combination shall exactly suit with the remote end M1 and M2 relays). Over and above the normal Tri-Vector Meter, the contractor should supply SEM Meters as per SRLDC/PGCIL Standards, additionally. 57 Control and Protection panel for 110kV Bus Coupler with BCU and additional Common BCU for Auxiliary control System and Monitoring including the panel as per standard and requirement of 110kV GIS 58 Design, Manufacture and Supply of Complete SAS system for 110kV GIS , as per detailed technical specification , SAS system Architecture andSLD , Reduntant Servers, Reduntant Gateway, Reduntant Routers with Hardware Firewalls,2 Nos Operator Work Station with HMI -Desktop (one operating work station with extended HMI at Nedumkandam (10Km away)) , 2 Nos. Engineering Work Station(Lap top and Desk top) , one metering PC with DCU for SAMAST metering and Remote Station Controls, necessary Panels and Furnitures etc completewith all necessary accessories, cables,converters, GPS based Time Syncronising Unit IEC compatible to cater data to and from all bays and transformer, SCADA compatible panels,interfacing /intergating line differential relay in CR panel, SAS gateway server panel etc to FODP/Communication equipment in communication room as per specification, including supply of all necessary converters for interfacing with the communication equipment , unarmoured OF cable , 40mm PLBHDPE pipe duct , all interconnecting cables , Patch chords devices etc. complete. The scope include integrating 33kV and 11 kV systems.SAS Architecture should be suitable for plug and play integration of future bays. [Including mandatory Spares as specified in volume 2 - Technical Specfications, Chapter 11, Annexure C] 59 Design, Manufacture and Supply of materials / item for Power Cable, Control Cables and instrumentation cable, Supply of various sizes of 1.1 kV FRLS-0H PVC armoured copper cable for control , Aluminum/ Copper LT power cable as per approved cable schedule (to be prepared by contractor and got approved), and provision of all types of cables from Power and Auxilliary Transformer and other equipments/switchgears, for the substation (Aluminium cables of size 185 mm2 and above shall be XLPE type) includingties , tags etc. supply of suitable size PVC pipe and accessoriesfor drawing exposed cables as per the technical specifications, IS/IEC Standards applicable. 60 12x4mm2 Control CableCopper 61 4x6mm2 Control CableCopper 62 4x4mm2 Control Cable Copper 63 2x4mm2 Control Cable Copper 64 19x2.5mm2 Control CableCopper 65 12x2.5mm2 Control Cable Copper 66 7x2.5mm2 Control Cable Copper 67 4x2.5mm2 Control Cable Copper 68 3x2.5mm2 Control Cable Copper 69 2x2.5mm2 Control Cable Copper 70 2x1.5mm2 Control Cable Copper 71 4x0.5mm2 instrumentation Cable Copper 72 4x10mm2 PVC InsulatedLT copper cables 73 2x10mm2 PVC Insulated LT copper cables 74 2x1.5 sq.mm or higher size PVC Insulated shielded copper cables for Transformer OTI & WTI wiring 75 20/25 mm dia FRLS PVC Rigid/Flexible Conduit including all clamps, clips etc. for Fire Alarm Panel and sensor wiring purpose 76 3 1/2C x300 Sqmm 1.1kV LTXLPE insulated armoured Aluminium cable 77 3 1/2C x 240 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 78 3 1/2C x 120 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 79 3 1/2C x 90 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 80 3 1/2C x 70 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 81 3 1/2C x 50 Sqmm 1.1kV LT XLPE insulated armoured Aluminium cable 82 3 1/2C x 35 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 83 3 1/2C x 25 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 84 4C x 16 Sqmm1.1kV LT XLPE insulated armoured Aluminium cable 85 1x 95 sqmm DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 86 1x 70 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 87 1x35 mm2 DC cable (stranded and flexible) NFPA category FRLSLH Copper Cable for battery. 88 Supplying aluminium cable tags with punching number and alphabets up to 7 digits or higher as per requirement for 220/33/11kV power cables including cost of all materials as per the technical and standard specifications 89 Hot dip galvanized ladder type cable tray with joint plate and N&B size300x100x2 with all accessories complete 90 Hot dip galvanized ladder type cable tray with joint plate and N&B size 450x100x2and with all accessories complete 91 Hot dip galvanized ladder type cable tray with joint plate and N&B size600x100x2 and with all accessories complete 92 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Conductor/ Earthing Materials and associated materials for Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable 93 Aluminium Bus bar 120*10mm 94 ACSR Wolf Conductor 95 110 kV 90kN Silicon Composite Longrod Insulator 96 110 kV 70kN Silicon Composite Longrod Insulator 97 110 kV Single Tension H/W and Accessories suitable for Single Wolf 98 110 kV Single Suspension H/W and Accessories suitable for Single Wolf 99 wedge – connector suitale for wolf/Kundah 100 wedge with paddlesuitale for wolf/Kundah 101 Earth Wire 7/3.15 mm Galvanised Steel wire with required hardwares accessories and earthbond 102 Tension Clamp and Tail Clamp for 7/3.15 mm Earth Wire 103 32/40mm MS rod for earthing 104 GI strip all sizes as per requirement for earthing 105 Clamp and saddle for GI strip/wire 106 Test link for lightning protection 107 1.5m GI lightning spike with fixing clamps 108 Design and supply ofVentilation system for GIS hall(positive pressure type)with prefilters and fine filters of washable type for 100% capacity of GIS hall, with air displacement of 5 times the volume of GIS hall per hour (one operating + one standby , consisting of two units each having capacity 5 times air changes per hourof GIS hall workingcyclically for 50% of time)with soft starting feature,comprising of GI ducts( with provision for nitrile rubber insulation if taken externally), fire dampers, exhaust dampers, grills, noise reduction system etc. complete.The system shall be monitored via SCADA including necessaryelectrical panels. 109 Design, Manufacturere, Testing at Manufacturs works, transporation and Delivery of the Fire and Safety Equipments and materials for 33/110kV Gas Insulated Substation as per technical Specifications and IS/IEC Standards applicable- Portable and wheel/ trolley mounted fire extinguishers for Control room 110kV GIS Hall, 110kV Switchyard Relay panel room of GIS Hall,Transformers and other Strategic locations including its installation at site 110 Dry chemical powder of 9kg capacity 111 Dry chemical powder of 25kg capacity 112 Dry chemical powder of 50kg capacity 113 CO2 gas type of capacity 6.5kg 114 CO2 gas type of capacity 22.5kg 115 Mechanical foam type capacity 9LT 116 Mechanical foam type capacity 50LT - 117 Fire Stand with 4 buckets(Including Concreting as per drawings) 118 SCADA compatible - Main Fire Alarm Control Panel (Zone of protection as per approved scheme) complete with Charger, Rectifier, Visual Display, battery back up complete as per the station requirement 119 Photo Electric type Smoke detector with base compatable for Fire Alarm Panel 120 Photo Electric type Heat detector with base compatable for Fire Alarm Panel 121 Supply of Beam Detector and Reflector for GIS with base compatable for Fire Alarm Panel 122 Audio Alarm with Hooters cum Speakers compatable for Fire Alarm Panel 123 Manual Call point of Break Glass Type with hammer and chain 124 Insulating Mat (Size 2000x1000x2mm) class A including its fixing at site as per Technical Specification and IS 125 Safety Chart for First Aid, Electric Shock & Fire and Fire Fighting Equipments including its fixing accessories complete 126 Lighting and General / Miscellaneous Items 127 Optical Fibre Cable (12F Single Mode and 12F Multimode) , SM and MM Patchcords, all necessary connectors complete, as per site requirement for extended HMI, bus bar protection other than SASas per site requirement and technical specification 128 Ground Enhancement Material (GEM) ( Per Bag -11.33 Kgs ) - Conforms IEC 62561-7 Standard. The GEM shall have Resistivity of less than 20 Ohm-cm and Environmental friendly 129 Visual Monitoring System (VMS) with surveilliancecamera as per technical specification and layout drawing (Including local PC monitoring set up having sufficient storage capacity, remote end PC monitoring if necessary set up shall be in the scope of supply) including necessary power and communicationcables, interconnecting hardwares, PVC pipes and all other accessoriesetc complete as per the technical specifications (minimum requirement : Fixed Camera : min 8 Nos, Pan Tilt Zoom Camera : min 2 Nos, Fixed Variable Focus: min 4 Nosand storage >8TB) 130 Design of Air Conditioning system and Supply of5 Star rated (as per latest BEE notification)2TR or higher capacity split type inverter Air Conditioners, with stabilizer, Power Isolator etc.for Control & Relay panel room, Communication room, SCADA room, Bay Control Room (each room has got minimum one unit of redundancy, cyclically operated with Room temperature indicator) as per detailed engineering and approval. Temperature indicators shall be integrated to SCADA 131 SPARES for GIS - 220/110kV 132 Tripping & closing coil(Each Breaker type Module) 133 Motor for disconnector of each type of equipment 134 Motor for CB spring charging (each Breaker Type) 135 SF6 Pressure Guage for Circuit Breaker 136 SF6 Pressure Guage for other compartments 137 SF6 Pressure Relief Device 138 Auxillary contact assembly for Circuit Breaker 139 Auxillary contact assembly for Disconnector/Isolator-each type 140 SF6 gas 141 Moisture absorbant catridge 142 NRV gas filling valve for equipment 143 Indication lamps and lamps for semaphores & annunciators- one for each type & colour 144 Annunciator full set each type with one set of relay card 145 Special tools for Installation and Maintenance -220/110kV 146 Gas Leakage detector - DILO make 147 Special spanners for General maintenance for supplied GIS 148 SF6 gas bottle locking , measuring and filling assembly with whole hose 149 Measuring Instruments 150 Clamp on meter- capable to measure mA range .• High sensitivity, miniature AC/DC clamp meter.Range: 200mA/2/20A AC, 2/20A DCMin. resolution for AC: 0.1mAMin. Resolution for DC: 1mAJaw size: 7.5mm all required accessories from following make and model Fluke,MEGGER,KYORITSU 151 Phase Sequence meter with Standard accessories -Fluke,MEGGER,KYORITSU 152 Digital Multimeter 279FC TRMS Thermal or advancedFluke,MEGGER Model 153 Analog Multimeter, with Standard accessories - Fluke,MEGGER,KYORITSU 154 SF6 gas Analyser including DEW point,purtity & Hygrometer etc.
Contract Date: Apr 01, 2026 Contract Value : 369.42 Crore
Boards / Undertakings / PSU No of Bidders 8
26.
Defence #9835139 AOC
Tender For Completion Of Incomplete Work For Provn Of Otm Accommodation (Ph-I Of Two Phs) At Panagarh Mil Stn Under Ge (P) Panagarh.; 1 Sch A Part -I (Building Works)Note:- This Sch is notpre-priced by MES and the pre-priced rate indicatedas Rs 0.00 under Col 5 signifies this fact only. 2 Completion of incomplete Building for signal unit with all fitting and fixtures etc. Complete all as specified and as shown on complete drawings. 3 Completion of incompleteBuilding for office accn/ Adm block with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 4 Completion of incomplete Building for JCO Mess and single living JCO accn with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 5 Completion of incomplete Buildingfor single living ORs accn / Dinning and cook house with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 6 Completion of incomplete Building for Storage Accn (Armouries)& Guard House alongwith hardstanding with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 7 Completion of incomplete Building for Store Room (General Authorisation) with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 8 Completion of incomplete ramp with all fitting and fixtures etc. Complete all as specified and as shown on drawings 9 Completion of incomplete Building for sentry post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 10 Completion of incomplete Building for Ironing Room with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 11 Completion of incomplete Building for Meter & Switch House with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 12 Completion of incomplete Pump House/ UG water tank with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 13 Completion of incomplete RCC OHT Tankwith 18mtr staging with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 14 Completion of incomplete Incinerator with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 15 Completion of incompleteFlag mast with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 16 Completion of incomplete Alarm post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 17 Completion of incompleteFire point with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 18 Completion of incomplete Refuse bin with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 19 Completion of incompleteDhobi ghat with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 20 Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATIONas listed in Schedule ‘A’ Part-II on Serial Page No. __ 21 Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III on Serial Page No. __ 22 Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. __ 23 Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V on Serial Page No. __ 24 Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI on Serial Page No. __ 25 Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII on Serial Page No. ___ 26 Lumpsum price worked out by the tenderer/ bidder for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VIII on Serial Page No. ___ 27 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX on Serial Page No. ___ 28 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLYas listed in Schedule ‘A’ Part-X on Serial Page No. ___ 29 Lumpsum price worked out by the tenderer/ bidder for LIGHTENING PROTECTIONas listed in Schedule ‘A’ Part-XI on Serial Page No. ___ 30 Lumpsum price worked out by the tenderer/ bidder for RAIN WATER HARVESTING / RECHARGE PIT as listed in Schedule ‘A’ Part-XII on Serial Page No. ___ 31 Schedule ‘A’ Part-XIII (MISCELLANEOUS ITEMS)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 signifies this fact only. 32 M & L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e10 %Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed .Note:Break down details of this Items is shown in Annexure ‘B’ in Schedule ‘A’ Notes. 33 (INTERNALELECTRIFICATION)Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box screws complete including PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point / call bell point controlled by one, one way switch complete all as specified and as directed. 34 All as per Ser Item No 13.02 here-in-above but for one ceiling/ exhaust fan point controlled by one switch complete all as specified and directed. 35 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one 5/6 Amps socket outlet points controlled by one, one way switch on independent board complete all as specified and as directed. 36 All as per item No. 13.04 above but one 5/6amps socket outlet point on the same board with other switches complete all as specified and as directed. 37 All as per item No. 13.02 above but for one Point wiring controlled by two nos two switch complete all as specified and as directed. 38 Material and labour for point wiring with 4sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 4 sqmm green colour as earth continuty conductor connected to common earth dolly for one15/16 Amps socket outlet points controlled by one, one way switch modular type on independent board complete all as specified and as directed. 39 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed stove enameled steel conduit of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point controlled by one, one way flame proof rotary type switch complete all as specified and as directed. 40 Supply and fixing switch flame proof rotary type with terminal box in LM6, 16 amps single pole 230 volts complete all as specified and as directed. 41 M & L for modular metal flush box 12 Module complete all as specified and directed. 42 M & L for modular white cover plate with frame, 12 module complete all as specifed and directed. 43 S & F for LED lamp 7 watt (retrofit) complete all as specifed and directed. 44 S & F LED type conical shape wall metal body with 1 no 7 Watt retrofit LED Lamp minimum lumen 700, complete all as specifed and directed. 45 S & F LED type table lamp / bed side light ( 3000k) Metal body 2 Watt minimum 50 lumen complete all as specifed and directed. 46 S & F telephone Socket (RJ-11) modular type complete all as specifed and directed. 47 S & F TV Socket modular type complete all as specifed and directed. 48 Supplying and fixing ceiling fan five star rated withBrush Less direct current (BLDC) 1200 mm sweep (without remote ) , 28 W complete withblades,down rod and accessories,230v,Min delivery 210 CFM with service value 6.00 BEE complete all as specified and as directed. 49 All as per Ser Item No 13.17 here-in-above but for 1400mm sweep, Minium air delivery 245 CFM with service value 6.00 BEE, five star rating with brushless direct current motor (BLDC) complete all as specified and directed. 50 Supplying and fixing exhaust fan made of sturdy Engineering plastic complete with lovers shutters, AC single phase, 230 V, 50 HZ , 1200 RPM, Copper winding, 250mm Sweep complete all as specified and directed. 51 Supplying and fixing exhaust fan noiseless square type metal body case , 450mm sweep heavy duty single phase (1400 RPM) ISI marked with blades flush mounting withlouvers, AC single phase 230/240 volts, 50 Hz including necessary fixing accessories and make good of surfaces complete all as specified and as directed. 52 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 6 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 53 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 8 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 54 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 4 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 55 Supplying and fixing MCCB 125 Amps, capacity 25kA, 4 pole, 415 volts (Adjustable thermal type & fixed magnetic setting) complete all as specified and as directed. 56 Supplying and fixing sheet metal enclouser for DBS Single pole and neutral 6 way double door with 200 Amps rated bus bar 240 Volt complete all as specified and as directed. 57 Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm diawith all fittings and conduit accessories concealed type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note:-(i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 58 Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm dia with all fittings and conduit accessories concealed type including one runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 59 Material and labour for sub main wiring with four runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less tha 25 mm dia with all fittings and conduit accessories concealed type including two runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) Four runs of cable with two runs earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 60 Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including complete all as specified and directed. {NOTE:- (i) Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item..} 61 (ROAD/PATH)M & L 225 mm thick (compacted thickness)wet mix macadam( WMM), with curshed stone aggregate and stone dust (as per design mix)of specifiedgrading, spread using mechanical paver as specified, watered, rolled & consolidated as specified to required gradient and camber complate all as specified & directed. 62 M&L for laying polythene paper black 150 micron with laps complate all as specified & directed. (Area for polythene paper without considering lap shall be measured and paid) 63 M&L and laying 150 mm thick (compacted thickness) wet mix macadam (WMM) with crushed stone aggragate of specified grading,spread using mechanical paver as specified, watered, rolled and consolidated as per required greadeant and camber complate all as specified & directed. 64 M&L for 100 m thick dry lean concrete (DLC) over a prepared subgrade with coarse and fine aggregate conforming to IS : 383, Size of aggregate not exc 40 mm (Grading and other parameters as per table 600 - 1 of MORTH, IRC SPR : 49 Specification) complate all as specified & directed. 65 M&L for cleaning and preparing the road surface and making good for road marking applying reflective thermoplastic white road marking paint (HOT APPLICATION) comforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass, beads, titanium dioxide, calcium carbonate, interfiller thermoplastic required for glass beads per square meter by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and as directed.Make of Thermoplastic Road marking paint/Retro-Reflective paint - M/s Asian Apcomark, M/s STP or M/s Shalimar Paints Ltd or M/s Berger Paints Ltd, M/s Jhonson & Nicholson Paints Ltd or M/s Jotun India Pvt Ltd. 66 (SEWAGE DISPOSAL)M&Lfor constrution of RCC Septic tankcoventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users Complete all as shown on drawing and as directed. 67 M&L for constrution Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.5 M effective depth Complete all as shown on drawing and as directed. 68 (EXTERNAL WATER SUPPLY) Design, supply, install, testing and commissioning Iron removal pressure feed type filtration plant 10000 GPH to with stand pressure 10 Kg/Sq cm with catalytic and filter media (as required size and grade / mesh to obtain potable water recommended parameters as per WHO) including MS frontal pipe (duly welded), Cocks, valves, (inlet outlet, back wash, rinse, bypass complete as per manufacturers instruction). Provision of main hole Hand hole strainer including air vent system, coagulant feeder with accessories, oxidation chamber with media, (MnO2) with all accessories suitable capacity with all fitting fixture, pressure gauges, RCC/PCC foundation as per OEM recommendation. Drainage system and connected to rising and delivery system including painting and writing complete. The technical details of Oxidation chamber and Multigrade filter are as given below:- 69 A) Oxidation Chamber- (i)Feed Flow - 40 M³/Hr. (ii) Operating pressure - 3.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm. (iv) MOC of vessel - MS. (v) Frontal Pipeline Size - 150/100mm. (vi) Media type - Manganese-di-oxide. (vii) Thickness in mm (shell and dish-ends) - 6 mm. (viii)Media Quantity - 600 Kg. (B) Multigrade Filter- (i) Flow rate - 40 M³/Hr. (ii) Operating pressure - 3.5-5.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm². (iv) Continuous duty cycle - 48 Hrs. (v) Backwash - 20 Min. (vi) Rinsing - 10 Min. (C) Filtering Media Details- (i) Media Type - Mixed sand. (ii)Depth of sand - 2800 Kg. (iii) Depth of Gravels support - 2000 Kg. (iv) Guaranteed life of filtering media - One year.(D) Vessels Details- (i) Type Cylindrical - Vertical. (ii)Dimension in mm (DIA X HOS) - 1600 X 2300 mm. (iii) Free board for back wash - 50%. (iv)Materials - MS. (v) Thickness in mm (shell and dish-ends) - 8-10mm. {Note:-- Rate deemed to be included with the followings:-(a)Raw water and treated water tested report of all parameter from National Test House Salt Lake. (b)Training to DEL Staff with required material and maintaining log book and other register as directed. (c) Electronic flow meter-01 including necessary wiring complete. (d)Butter fly and gate valves as required.(e) 2 Nos air compressor of capacity 210 CFM with 3 Phase Motor, Starter, air pipe connection including electrical connection complete. 70 Supply, install, lowering, testing & commissioning of submersible pump set 8 stage, suitable forminimum head 40 Mtr with 635 lpm dischage with electric driven motor of capacity 15 hp, 415 V AC, TP with operational efficeiency performance and durability wide voltage range 350-440 Volts, super finished water lubricated bush bearing, with less speed drop motors with reflon bearing and sand guard complete all as specified and directed by Engr-in-charge. 71 Trail drilling of bore of size 250 mm dia upto 120 mtr depthby direct rotary/ DTHmechanical system for injection wellin any kind of soil strata including hard stone/boulders and submitting the strata detail both graphically recorded as well as strata results including testing of yield , complete all as specified and as directed. 72 Reaming of bore well from 250 mm dia to 525 mm dia hole in three steps from 250 mm to 350 mm, 350 mm to 450 mm and 450 mm to 525 mm dia bore siutable for lowering ERW Mild steel casing pipes and gravel packing for the required length (i.e 50 mtr depth) below the ground level , complete all as specified and as directed. 73 All as per item no 13.41 here-in-before but exceeding 50 mtr and upto 170 mtr depth, complete all as specified and as directed. 74 Supply, assembling, lowering and fixing in position 250 mm nominal (10) bore ERW MS housing pipe, ISI marked,of 8 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth upto 40 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding , complete all as specified and as directed. 75 Supply, assembling, lowering and fixing in position 200 mm nominal (8) bore ERW MS housing pipe, ISI marked,of minimum 8.0 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth exceeding 40 mtr and upto 120 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding, complete all as specified and as directed. 76 Supply, assembling, lowering and fixing in position low carbon galvanized (LCG) steel strainer pipe 200 mm nominalbore of wall thickness 7.00 mm cagetype wire wound screen ‘V’ shaped profile in suitable length having slots of size 1.6 mm width including necessary end coupling,electric Arc welding as required and including special sockets for connecting to MS pipe, complete all as specified and as directed. 77 Supply and fixing mild steel reducer suitable for (250 x 200 mm ) bore casing pipe, 10 mm thick, fitted to casing pipe as per IS 2800 by means ofelectric Arc welding ,complete all as specified and as directed. 78 M&L for carrying out electro logging test upto complete drilling depth of tube well for fixing water strata and submitting of Report including its interpretation by a qualified Hydrologist/ground water expert , complete all as specified and as directed. 79 S&Fmild steel bail plug assembly suitable for 200 mm bore casing pipe internal threaded with strong iron hook, screwed and welded to casing pipe as per IS 2800 , complete all as specified and as directed. 80 Supply, filling and packing washed pea gravels of size 2 mm to 4.6 mm all around casing pipe and slotted pipe, complete all as specified andas directed 81 S&F mild steel housing clamps 1200 mm long 100 mm wide , made out of 20 mm thick MS plate made to shape for 250 mm bore casing pipe with necessary bolts, nuts and washers at ground level, complete all as specified and as directed. 82 Developing of tube well by means of air compressor, for number of hours, until sand free clear potable water is obtained including testing by using diesel engine driven turbine pump to get maximum yield and discharge including supply of yield test result , complete all as specified and as directed. (Note : The rates of DHPP is inclusive in the quoted rate) 83 S & F well cap made out of 5 mm thick MS Plate with provn of suitable holes for passing two runs of flat 3 core PVC insulated sumersible cable motor and one run of SWR, 100 MM dia column pipe and suitable for fixing 250 mm nominal bore ERW heavy duty MS of 8.0 Mm Wall thickness casing pipe complete all as specified andas directed. 84 S&F pressuregauge with isolation cock suitable for a working pressure of 7 Kg/cm² (Liquid based High Intensity), complete all as specified and as directed. 85 Supply and laying flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work , complete all as specified and as directed. 86 S&F round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed ,complete all as per directed. 87 Supply , lowering and fixing MS column pipe 100 mm bore, medium grade, confirming to IS, 3 meter long pipe both end flanged, threading, welding and drilling of holes, cutting of ducts of size 10 mm x 20 mm 2 No. in each flange for fixing submersible cable, including rubber gasket of suitable size, nuts, bolts, washer etc including painted internally and externally with two coat of non corrosive non toxic bituminous paint including making all type of connections as required, complete all as specified and as directed. 88 Supply , install, testing and commissioning of cubical housing cabinet type weather proof powder coated LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proofof CPRI approved,openablefrom both front and rear side made of2 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- 89 (i) Aluminium Bus bar 160 Amps -25 KA breaking capacity(ii) Incoming MCCB, 4 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacityQty 1 No(iii) Outgoing MCCB, 3 pole, 32 Amps, 415 Volt AC, 10KA rupturing capacityQty 4 Nos(03 For submersible pump and 01 standby)(iv) Outgoing MCB 4 Pole 32 Amps, 10 KA, 240 Volts - 01 Nos(v) Star delta motor starter suitable for 15 HP motor pump - 03 Nos(vi) LED indicating lamps - 03 Nos(vii) Digital Volt meter (Size - 96 x 96mm) 0-500 Volts with selector switch - 01 No(viii) Digital Ammeter (Size96x96mm) With selector switch including CT ( 100/5Amp) with all connection- 01 No(xiv) Matering and accessories complete all as directed by Engr-in-Charge. 90 Supply, installation, commissioning and testing of 200mmsluice valveof cast iron body flangedconforming to IS-14816, PN-1.6 Non rising type spindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 91 Supply, installation, commissioning and testing of 150mmsluice valveof cast iron body flanged conforming to IS-14816, PN-1.6 Non rising typespindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 92 Material and labour for Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 93 Material and labour for Construction of brick masonry valve pit of internal dimension 60 cm x 60 cm x 60 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 94 Supply, install, testing & commissioning of Centrifugal pump suitable for minimum, Discharge 635 LPM at 30 Mtr head with cast iron casing, bronze impeller, SS Shaft, electric driven motor of 10 HP, 415 V, TP suitable for under ground sump and install complete including PCC foundation as per manufacture instruction complete all as specified and directed. 95 Supply, install, connecting, testing & commissioning of high pressure single head adjustable chemical dozing system of the folowing specification : (a) Adjustable high pressure 100 PSIG Power input 230 V, 50 HZ, Max flow rate 02 US GPD to 40 US GPD with mandatory assecceries like lead tubing connecting ferrules, check valves, 170 ltr FRP solutin preparetion tank with lid, port hole, inlet/outlet/drain connection, level guage ete and fitted with 900 RPM motor PVC agitator combined with 100 ltr dosing tank lid port hole inlet/outlet/drain connection, level guage etc either fitted with 900 RPM moter and PVC agitator complete all as speficified and directed.Make : Any make of E-in-C approved or ISI Marked of any make as approved by Accepting Officer. 96 Supply and laying DI Pipe 200mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 97 Supply and laying DI Pipe 150mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 98 M&L DI Fittings bends (any type radius and angle) tapers any type, (straigth, bend, increasing, decreasing or double socket etc) Tee pieces single branch Y junctions double branch, cross (all sockets or socket and spigout ) collars, caps and plugs upto 300 mm bore complete all as specified and directored. 99 (EXTERNAL ELECTRIC SUPPLY)suply , installation and commissioning of compact secondary substation (CSS) 315KVA comprising to following parameters:-(a) Housing to made with conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to high voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lighrening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h) Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside fo the CSS.(l) Necessary HT and LT cable / earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 100 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs adn PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet enclosure with automatic sagety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch. 101 (vii)Shunt trip coil- 230 V, AC(viii) Safety interlock locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, space heater with thermostat, fuse adn ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle(xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 315 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 25.% on HT side all technical specification comprising to IS 11171 update version part with all necessary satndard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 315 KVA (ii)Primary Voltage - 11 KV AC(iii) Secondary Voltage - 433 Volts . 102 (iv)Neutral earthing should be solidly earth system (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs). q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 103 Suply , installation and commissioning of Compact Secondary Substation (CSS) 250 KVA comprising to following parameters :-(a) Housing to bemade with Conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to High voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lightening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h)Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside of the CSS.(l) Necessary HT and LT cable / Earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 104 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs and PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch.(vii)Shunt trip coil- 230 V, AC(viii) Safety Interlock Locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, Space heater with Thermostat, Fuse and ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle. 105 (xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 250 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 2.5% on HT side all technical specification comprising to IS 11171 update version part with all necessary standard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 250 KVA (ii)Primary Voltage - 11 KV AC 106 (iii) Secondary Voltage - 433 Volts (iv)Neutral earthing should be solidly earth system. (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance.(p)LT Panel for 250 KVA Transformer made with 2 mm CRCA sheet with necessary angle iron frame and vermin proof font side openable double door with necessary locing arrangement opening for bus bar / cable entry opening for natural air ventilation / cooling necesary Ammeter, Voltmeter, Selector switch, CTs , suitable size bus bar, paints and primer with Air Circuit Breaker (ACB) as incomer 630A, 50 KA, 415 V , AC, 50 Hz, 4 Pole with neccesary setting and microprocessor control draw out type bus bars, as outgoing MCCB 200 Amps, 35 KA - 02 Nos, MCCB 160 Amps, 35 KA - 02 Nos & 32 A MCB 4 Pole - 04 Nos. (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs).(q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 107 Supply and fixing LED street light fittings on ploes capacity 45 Watts, high pressure die cast aluminum housing IP 66 rating front cover made of toughened clear glass, suitable for pole mounting wih bracket arm 40mm dia, Gl light grade pipe upto 1.4 m long, bend to required shape, clamp 40mmx6mm or required length including nuts & bolts fixed on steel poles complete all as specified.Model No : ENDURASUNDOWNSL45WLED765PASYBOTG of make : Havells or equivalent make as per Appendix D. 108 Supply & Fixing junction box with 3 Phase terminals and size of box 130mm x 180mm x 77mm or nearest higher size made of polycarbonate with IP 66/67 degree of protection, dust proof, water tight,shock proof, fire retardant,with internally embedded gasket fitted with heat treated bakelite for terminals block and PVC Glands for cable entry complete all as directed 109 M&L Three core 1.5sqmm(nominal area)service wire PVC insulated copper conductor FRLS, multi stranded, unsheathed 1100 volts grade IS-694 marked andfrom junction box to street light fitting through steel pole withPVC conduit & necessary clamps, bolts & nut etc required for fixing complete all as specified and directed. 110 Supply , install, testing and commissioning of cubical housing cabinet type conforming toCPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowings :-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -200 Amps , cable entry (incomming and outgoing ) form bottom with cable gland Incomming : 125 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No (Incoming from CSS)Outgoing -(a) MCCB 4 pole 100 Amps 25 kA - 02 Nos (for signal unit and 1 standby)(b) MCCB 4 pole 16 Amps 25 kA - 2 Nos (For OFFR Living ,meter or switch house and and 01 No for street lights)(c)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor(d) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) LED indicating lamps -03 Nos 111 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -400 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 250 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 200 Amps 35 kA - 01 Nos (Adm buidling)(b) MCCB TPN 16 Amprs 25 KA-02 Nos (Guard house and standby)(c) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(d) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No(e) LED indicating lamps -03 Nos. 112 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approvedLT panel board Outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -600 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 315 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 125 Amps 35 kA - 03 Nos(02 Nos for OR Accomodation and 01 Nos standby)(b) MCCB 4 pole 63 Amps 25 kA - 01 Nos(JCO Accomodation and JCO Club) (c) MCCB 4 Pole 25 Amprs 25 KA - 01 Nos (Drying and ironing room)(d) MCCB TPN 16 Amprs 25 KA - 02 Nos (Street lights and one standby)(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos (g) LED indicating lamps -03 Nos (h)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor 113 Supply, install, testing and commissioning of Automatic Power Factor Correction (APFC) panel board of aggregate capacity 15 KVAR suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, outdoor type, cubicle, floor mounted, free standing dust and vermin proof, air ventilation made out of 3 mm thick CRCA sheet duly powder coated, Manufactured shall be CPRI norms and as approved by GE, factory made.Panel board shall have front and rear opening with hinged type doors and rubber gasket, handles, industrial type locking arrangement, cable alleys, switch gear compartment, bottom cable, entry holes for incoming and outgoing cables, earthing terminals, danger notice plate, Aluminum bus bar duly covered with heat shrink sleeves of colour coded duly fixed on DMC / SMC insulators housed in a separate bus bar chamber including control wiring with PVC insulated, flexible, multistranded copper conductor cables of adequate size and of adequate length for connecting of capacitors, contactors etc duly ferruled crimped with suitable lugs / thimbles and including connecting of incoming and outgoing cables. Panel board shall be mounted on and including MS angle iron frame of suitable size duly painted and PCC1:2:4 type B1 for foundation / Platform to suit the site requirement complete all as specifiedand directed and comprising of following:-(i) APFC relay microprocessor based digital display type of 9 stages suitable for operation of PF upto unity – 01 No. 114 (ii) MCCB 320 Amps, 4 pole, 50KA, 415V, 50HZ – 01 No for incoming.(iii) MCCB 80 Amps, 4 pole, 25KA, 415V – 03 No’s for capacitor outgoing.(iv)MCCB 40 Amps, 4 pole, 25KA, 415V – 01 No for capacitor outgoing.(v)MCCB 16 Amps, 4 pole, 25KA, 415V – 05 Nos for capacitor outgoing(vi) MCB SP 0.5 to 5 AMPS, ‘C’ Curve, 240V-09 Nos as per circuit control.(vii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -05 Nos.(viii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -02 Nos.(ix) Capacitor Bank 1 KVAR, 3 phase, 440V MPP type including suitable rating contractor -01 Nos. 115 (x) LED indication lamps RYB – 01set.(xi) Auto / manual selector switch -01No.(xii) Push button and indication lamp for each capacitor bank -01 set.(xii) Digital voltameter with selector switch -01set.(xiv) Digital ammeter with selector switch & CT’s -01.(xv) Aluminium bus bar TPN 480 Amps rating -01 set.Note: The contractor should be factory inspection and drawings approval by the GE / Engineer-in-Charge before procurement after commissioning of APFC panel the power factor (PF) to achieve 0.95 to 0.99 mandatory at any load condition automatically. 116 Supply and fix solar street light smart integrated solar system all in one with MPPT (Maximum Power Point Tracking) charge controller ,Tilable LED Panel,Adjustable AIO mounting angle ,mono crystalline solar panel ,PIR motion sensor, and 6m tubular pole with 30 wattLED light at a rate 100 lm/w, 60wp, 75 AH (Lithium ferrous phosphate battery luminaries must have a life of greater than 50,000 hours and have IP 66 rating, the modules are to bedesigned to with stand corrosive atmosphere and heavy wind loads. the modules are to be certified for standers IEC 61215, IEC 61730 (Safely class I & II) complete all as specified and directed. 117 Supply and fix LED post top lantern decorative typeo fttings for 360 degreee indirect light on pillars of capacity 40 watts high pressure die cast aluminium housing IP 65 rating, suitable fr mounting 40 dia GIlight grade pipe upto 0.5 m long or required length including nuts and bolts and fixed complete all as specified and directed.Model No : RUBYPT40WLED757PSYMTOPC OF MAKE : Havels or equivalentmake as per Appendix D 118 M&L fpr boring holes horizontally under road without damaging the surface of road (minimum 1 mtr below the road surface/ footpath with the help of GI tubing not exceeding 100mm dia bore for passing of UG cable complete all as specified and directed. 119 (REFGIGERATION & WATER COOLER) Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 308 - 315 ltrs capacity, conforming to IS 15750 (2006) for frost free, with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 120 Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 192 - 210 ltrs capacity, conforming to IS 1476 for direct cool with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 121 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 320 ltrs, BEE 5 star rating complete all as specified and directed. 122 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 400 ltrs, BEE 5 star rating complete all as specified and directed. 123 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacityof 40 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 124 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 120 ltr and nominal cooling capacityof 60 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 125 S & F Voltage stablizer of capacity 2 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 126 S & F Voltage stablizer of capacity 1 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 127 (DG SET) M&L Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected tousing galvanised iron strip 32×6mm as earthing lead earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated by Engr-in-charge including testing on completion. 128 Supply and installation testing and commissioning silent Diesel Enginegenerating set 415 volts 40 KVA3 phase 0.8 power factor, 50 Hz, 1500RPM self exicited self regulated brushlessAC generator installed including AMF panel,suitable for ambient condition at Panagarh and confirming to condition under ISO 3046, IS:10001/ 10002,BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :- (A) Alternator:- Synchrounous alternator rated at 40 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system.The alternator shall be brushless, single bearing, self excited/ self regulated with an AVR. The alternator will be suitable for climate and shall generally confirm to IS: 4722 :2001. The salient features of the alternators are :- (a) +-1% voltage regulation (max) in static conditions.(b) IP:23 protections with class H insulation.(c) Permanent lubricating bearing. 129 (B) Diesel Engine:- Adquate capacity of diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500RPM, as per relevant IS/BS complete with standard accessories. (C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent (to comply GRIHA and other agencies norms) canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimentional accuracy of holes within 0.1 mm.Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility (D) AMF panel : Automatic Mains Failure (AMF) panel made of CRCA sheet of 2 MM thick including necessary arrangement to install, testing and commissioning & connecting ot load cable to up ot changeover switch, suitable capacity of 4 pole MCCB complete all as per OEM recommendation.(E) Civil Works :- All civil works including PCC platform and related foundations incl for panel and equipments incl making goodof disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommendedby the manufacturer. 130 (F) AMF Panel Specification shall be as per manufacture instruction.Note :-The contractor shall be arrange for artificial load resistive for testingof DG set at site and the cost is deemed to be included in the quoted ratesMAKES :- Make of engine : CUMMINS/KIRLOSKARGREEN/ASHOK LEYLAND/ GREAVES COTTON.Make of alternator : KIRLOSKAR GREEN / ALSTOM / CROPTON GREAVES /SIEMENS 131 Supply, erecting,testing aand commissioning of solar water heating system with heat exchanger for cold & warm regions respectively with solar evacuated tube collection conforming to IS : 12933 (Part - i ) with amdt No 1 and IS : 12933 (Part 2) /2003 suitable for inlet water with chlorine and fluorine content up ot 100 ppm and supply hot water at the outlet of 200 litters capacity with elctrical back up meeting specifications as under and comprising of followings :-Supply and fixing rotational moulded polyethylene water storage tank (Cylindrical Vertical with closed lockable top with lid and locking arrangement) hoisted and fixed in position all as specified in SSR Part -I of capacity 200 Litters complete for storage of cold water feeding to solar water heater, including staging made out of MS Angle iron 50x50x6 mm all as specified and directed at site by Engineer-in-Charge.Material :- Soalr water heating System : Comprising of solar Evacuated tube Collector, Collectors stand assembly.Staniless steel insulated hot water Storage tank with heat exchange and various other components . Solar evacuated tube collector component shall have :Evacuated tube collector component shall have : solar Evacuated tube collector cover plate made of toughened glass.Sheet for absorber made of copperAbsorber made of copper sheet and copper tube.the minimum thickness of Aluminium shall be as under:- (a) Channel section for sides 1.6mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm sheet for entire body 1.0 m AbsorberAbsorber shall consist of riser, header and sheet for absorer. The diameter of header shall be 25.4 +/- 0.5 mm and thickness 0.71 mm. The Diameter of riser shall be 12.7 +/- 0.5 mm and thickness 0.56 and made of copper only. 132 S & F Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed. 133 Rain water Harvesting /Recharge PitS & F 150 MM perforated UPVC pipe with 20% Perforation complete all as specified and directed. 134 S & F 150mm bore PVC (SWR) vent cowl complete all as specified and directed. 135 M&L for hand packed gravel (Stone chips 12.50mm) for filling in bore holes and inside of recharge pit complete all as specified and directed. 136 Boring for 350 Mm Dia bore to a depth of 40 mtr in soil and getting out and disposal of spoil to a distance of 50 mtr using DMC method ( Direct mud Circulation) complete all as specified and directed. 137 GRIHA RATING FOR FOLLOWING BUILDING:-Minimum 3 star GRIHA rating shall be obtained for the following buildings which includes pre-certification and final ratings from approved aggency(a) OFFICER/ ADMIN BLOCK (b)SINGLE living JCOs ACCN(c) SINGLE living HAV/OR ACCN (T/S)Note :- 01The GBA (Green Building adviser) ofr obtaining GRIHA certification shall be approved by Accepting Officer.02. The GBA shall be responsible for all necessary actions for obtaining final GRIHA rating as per following guide lines:- (a) Pre-Cretification :-1. Submission of GRIHA per certification documents to certification agency as applicable immediately after the issue of Job/Work order.2. Analysis and suggest improvement/correction in the MEP/Other relevant drawings/documents and draft tender of the subject work for GRIHA star Rating (Min Three Star).3. Preparation, Submission & uploading all the documents in accordance with the GRIHA requirment, documentation shall be supported by drawings, test result quipment catalogues & calculations.4. Selection of equipment & material.5. To facilitate the planning team for selection of appropriate energy efficient & eco -friendly technologies, equipment & materials for the building e.g lighting system ,white goods, water treatment technologies, renewable energy, nontoxic paints, rapidlly renewable materials, recycled materials, ecofriendly materials etc.6. preparation of vendors & suppliers list for inclusion in the tender & working out specification of equiptment & materialto suit the GRIHA requirement. 138 7. Develop templates for GRIHA calculations to achieve certain points, this include materials related criteria, construction of waste management at site, energy calculation etc.8. conduct solar path analysis for each to achieve the best design ( shading device, Orientation etc.)9. Conduct solar path analysis for each fenestration to achieve the best design ( shading device, orientation etc)10 Perform day light analysis to ensure optimun condition achieved as per the guidelines provided by ECBC 2007.11. Perform day light analysis for window -wall ration, glass peropertiies (SHGC) & Providing recommendations to meet the compliance of ECBC 2007.12. Perform hourly calculation to show that thermal comfort condition as well as non-condition area are cachieved.13. Perform energy simulation to predict the energy performance of energy system in the bldg is less than the benchmarked energy perfomance as prescribed by GRIHA.14. Submit of ECBC compliance document to show that compliance fo mandatory requirment of ECBC are meet.15.Submission of draft specification to comply with relevant criteria of GRIHA for inclusion in tender documents.16. Liasoning and coordinating with GRIHA team for registration of project, uploading relevant document. Responding ot queries, observations, modification and corrections given by GRIHA team within specified time framed and reporting client with lates update.17. completion of all documentation requirement and formatlities before conclusion of main bldg. Contract and obtaining pre-certification with 3 or above star rating. 139 Final Rating:-Acquiring of Final Post GRIHA (minimum 3 star rating) certification approval from GRIHA including changes in drawings/ design during execution of work.Note:-The consultancy fees is inclusive of the following:-1. Pre-certification Registration Fees2. Certification registration Fees3. Site visit of GRIHA Official4. Site visit of GRIHA Official5. Third party EvaluatorPayment Schedule :-(i) 10% after pre-certification(ii) 50% at finalisation of specification(iii) 40% after obtaining GRIHA certification 140 Providing and fixing white vitreous china floor mounted water closet of size 360X640X685 mm of approved shape including providing and fixing vitreous china cistern with duel flush fitting, of flushing capacity 3 litre/6litre (adjustable to 4litre/8litre, including seat cover, and cistern fitting nuts, boltsand gasket etc complete all as specified and directed.Model No: SLS-WHT--6851P of make Jaquar of equivlent make/model as specified in Appendix D. 141 Providing and fixing white vitreous china wash basin for under counter mounting, specially fabricated brackets, painted whit, brass tap, 32 mm C.P. Wast, 15mm C.P. Brass self closing tap, connection pipe & rubber adopter for waste connection, complete including cutting and making food the walls, wherever requird complete all as specified and directed.Cat No : CNS_WHT_705 for wash basin ofmake Jaquar& Cat No PRS-031 for 15mm C.P brass tapof make Jaquar or equivlent make/model as specified in Appendix D. 142 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. Size 485 X 310 X 710 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction of Engineer-in-Charge.Cat No : URS-WHT-13255 of make of equivlent make/model as per Appendix D 143 Providing and Fixing of P.V.C waste Flexible pipe 40mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 144 Providing and Fixing of P.V.C waste Flexible pipe 15mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 145 Providing and fixing C.P. Brass angle valve 15mm dia for basin mixer and gyser pointsconforming to IS : 8931 complete all as specified and directedCat No FLR-CHR-5053N of make of equivlent make / model as per Appendix D. 146 Providing & fixing Liquid soap container of standard shape with bracket of the same material with snap fitting of approvedquality and colourcomplete all as specified and directedCat No : CAN-1135N of make of equivlent make / model as per Appendix D 147 Provinding & fixing Sink cock 15mm nominal bore of approved quality and colour complete all as specified and directedCat No : FLR-5347ND of make of equivlent make / model as per Appendix D 148 Provinding & fixingCP Brass Health faucet with 1.5M S.S Flexible Tube with wall hook including screw, Nut, bolts, cutting wall/floor and making good the same whatever required complete all as specified and directedCat No : ALD-CHR-583 of make of equivlent make / model as per Appendix D 149 Provinding & fixingCP Brass Bid cock Including wall fange, Connections, screws, nut, bolts, cutting wall/floor and makiing good the same whatever requiredcomplete all as specified and directedCat No : FLR 5037Nof make of equivlent make / model as per Appendix D 150 Provinding & fixing sink CP Wall mount double Robe Hookfixed to wooden cleats with C.P Brass screws, cutting wall/floor and making good the same whateverrequired complete all as specified and directedCat No : CAN-1161N of make of equivlent make / model as per Appendix D 151 Providing and fixing of straight type Macfit Single body push fit type WC pan connector with factory supplied srpring loaded seal guard of mcalpine, UK with integral single mould sealing fins made of flexible eva body, including bush/ adaptor for use with C.I pipe as supplied with the pan connecrtor complete all as specified and directed. Model : MAC 1 of make Macalpine of equivlent Model as approved by E-In-C or Accepting officer. 152 HOT WATER SUPPLYSupply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 15 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 153 Supply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 25 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 154 S&F CP Brass stop cock (concealed) of 100mm dia of standand design conforming to 15:8931 complete all as specified and directed. 155 Providing and fixing sound insulated PP piping system as per ON EN 1451 _ Part I-6 & EN 12056 part I-5 with 3 Layer pipe made of PP-C +PP-MV+PP-C in Blue Ral 5014 (Halogen and calcium free) colour, Push-fit type, food safe having high impact and stiffness, offering sound level of not more than 22dBA at a flow rate of 4 I/S and having pipe ring stiffness as per ISO/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560 with all necessary fillings in blue colour, filled with factory fitted lip ring of make : Polyplast or equivalent make as approved by GE suitable for PP110mm dia Pipes complete all as specified and directed. 156 All as per item No 14.24 here-in-after but for PP 75mm dia pipes 157 All as per item No 14.24 here-in-after but for PP 40/50mm outer dia meter pipe (For wash basin etc) 158 Providing and fixing floor trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connection, 110mm inlet& 110m outlet long hight complete all as specified and directed. 159 Providing and fixing 110 X 50mm UPVC Floor Drain / Plain Floor trap complete all as specified and directed. 160 Providing and fixing SS Grating Over Floor Trap& Floor Drain 127 X 127mm complete all as specified and directed. 161 M&L concrete bed to drain pipe including packing under and lacking against the side of pipe after they are laid and tested with PCC (1:4:8) type D-2, for 110mm dia complete all as specified and directed. 162 All as per srl item No 14.30 here-in-after but for PP 40/50mm outer dia meter pipes. 163 S&F clean out cap plug (FCO/COP) for cleaning of same materials (POLO KAL NG) for PP 110mm dia complete all as specified and directed. 164 S&F 3-layer PPR-polypropylene random copolymer conceled pipes SDR 7.6 (PN-16) UV stabilized and antimicro bial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting for 50mm outer dia laid in trinches complete all as specified and directed.
Contract Date: Mar 17, 2026 Contract Value : 59.85 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
West Bengal View Result →
27.
Defence #9823933 AOC
Tender For Provision Of Perimeter Road And Connected Items At New Location Af Station Sonegaon.; 1 ROAD WORKS 2 Earth work in excavation of all kinds of soils by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m complete all as specified anddirected. 3 Removing excavated material to a distance exc. 250m but n.exc. 500m and depositing where directed at a level n.exc. 1.5 m above the starting point and depositing Complete all as specified and directed. 4 Removing excavated material to a distance exc.1.50 km and n.exc 5.0 km and depositing where directed at a level n.exc. 1.5m above the starting point and depositing Complete all as specified and directed. 5 Rolling and consolidating to required gradient and camber with power roller of capacity exceeding 8 tonne but n.exc 12tonne to achieve 98 % OMC, soaked CBR at 6% and rolling with vibrator roller of capacity 80-100 KN complete all as directed. 6 M&L for Moorum/red bajri filling in floors or pavings, laid in layers n.exc. 15 cm thick, spread, levelled and rammed including watering, consolidated to required gradient and camber with 10 to 12 Tonne power roller complete all as specified and directed. 7 M&L for 200 mm thick (compacted thickness) GSB Grade IIin single layers of as specified Table 900-1 of MoRTH specification for Road and Bridge works, 2013, in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag of combination there of as per the grading requied. The materials are mechanically mixed, spread and levelling and rolling with vibrator roller of capacity 80-100 KN static weight for achieving required compaction density of at least 98% of the Maximum Dry Density. Consoldating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specification for Road and Bridge works 2013 Complete all as specified and as directed. 8 M&L for 100 mm thick (compacted thickness) GSB Grade II in Single layers of as specified Table 900-1 of MoRTH specification for Road and Bridge works, 2013, in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag, of combination there of as per the grading requied. The materials are mechanically mixed, spread and levelled and rolling with vibrator roller of capacity 80-100 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consoldating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specification for Road and Bridge works 2013 Complete all as specified and as directed. 9 M&L for 150 mm thick (compacted thickness) Wet Mix Macadam (WMM) (laidin 2 layer of 75 mm each layer) grading as per table 400-13 of MoRTH specification for Road and Bridge works 2013 manufactured in WMM plant, material comprising of clean, crushed, graded aggregate and granular material premixed with water to a dense mass, spreading with sensor paver and static weight and consolidating to required gradient and camber complete all as specified and directed. The finished surface tolerances to be as per Table 900-1 of MoRTH specifications for Road and Bridge works 2013 Complete all as specified and as directed. 10 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. 11 M&L for Premix bituminous, macadam laid/rolled and compacted to required gradient and camber (consolidated thickness 75mm or less with 4% binder content of paving bitumen any penitration by weight of total mix.) Complete all as specified and directed. 12 M&L for semi-dense asphaltic concrete of 40mm consolidated thickness with 5.5% binder content of paving bitumen any penitration by weight of total mix, rolled and compacted to required camber and gradient complete all as specified and directed. 13 Applying evenly a priming coat with bituminous primer at 10 kg per 10 sq metre Complete all as specified and directed. 14 Applying evenly a tack coat with bituminous primer at 5 kg per 10 sq metre Complete all as specified and directed. 15 S&F of 150 mm dia Reinforced concrete pipes,class NP3, laid under WBM road to allow the water pass through it as drain pipeand Concrete bed (1:4:8) Type D2 to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested Complete all as specified and directed. 16 S&F of 450 mm dia Reinforced concrete pipes,class NP3, laid under WBM road to allow the water pass through it as drain pipe etc ,Complete all as specified and directed. 17 M&L for prepairing bituminous surfaces of road and marking 2.5 mm thick centre lines, stop lines, dashes, arrows etc, and the like n.exc 10 cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and as directed. 18 Supply and fixing cat eye solar reflective type of metel body alloy size 100mm X 100mm X20mm with PMMA strip lens reflector model No. DA 972.0 fixed with and including MS studs of suitable size as per manufacturer instructions complete all as specified and as directed. 19 S & F metal tubular dealineator made out of ABS round body fitted with 2 Nos 65mm dia highly reflective reflactors made out of PMMA and mounted on 45/50mm dia mild steel pipe of 600mm ht duly powdre coated and thermo plastic elastomer 3bands of green , red and yellow reflector radium tape of 25mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300mm) type B1 complete all as specified and as directed. 20 Earth work in excavation of all kinds of soils by mechanical means (hydraulic excavator) means over areas (exceeding 1.5 m and n.exc. 3.0m in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m complete all as specified and as directed. 21 Earth work in excavation of all kinds of soilsby mechanical means (hydraulic excavator) means over areas (exceeding 3 m in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m complete all as specified anddirected by Engineer-incharge. 22 M&L for Plain Cement concrete in foundations filling and mass concrete (1:4:8) typeD-2 using 40mm graded stone aggregate Complete all as specified and as directed. 23 M&L RCC M- 30 design mix using 20 mm graded stone aggregate in foundation, including rafts, footing, foundation beams, plinth beam, bases for column, slab for culvert etc complete as specified and as directed. 24 M&L RCC M-30 design mix using 20 mm graded crushed stone aggregate in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. 25 M&L RCC M-30 design mix using 20 mm graded crushed stone aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. 26 Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat and fair finished surfacecomplete all as specified and directed. 27 Use andwaste of formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, flat and fair finished surface complete all as specified and directed. 28 Use andwaste of Formwork to sofits of suspended slabs such as roof slabs, floor slabs, landings and similar work, exc. 200 mm thick (horizontal or sloping), rough finished surfaces of concrete in flat complete all as specified and directed. 29 Use andwaste of Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide RCC/PCC band in walls, spanning and opening complete all as specified and directed. 30 M&Lfor Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified. 31 Returning filling in including spreding lavelling, watering and well ramming in layers n.exc 25 cm. 32 Excavating in trenches n exc 1.5 m width and n exc 1.5 m in depth for foundation etc n exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and as directed. 33 M&LBrickworkwithsubclassBoldsizebricks, straight or curved on plan exceeding 6m mean radius,builtincementmortar(1:4)competeallas specified and as directed. 34 M&LRendering15mmthickonfairfacesofbrick work or concrete surface in cement plaster1:3 finishing the surface even & smooth with using extra cement & with WPC (WPC will be measured & paid seperately) complete all as specified & as directed. 35 Supply only Integral waterproofing compound. 36 M&L2 coat of cement base paint on plastered surface of brick work complete all as specified and as directed. 37 M&LPCC(1:3:6)typeC-1(using12.5mmgraded stoneagggregate)asincoping,benchingof manholes, blocksforfixing of rungs andsimilar works including weathering, slightly rounded or chamferedanglesandthroating asdirected including necessary form work complete all as specified and as directed. 38 S & F Speed Breaker (Yellow and black ) having high resistance to impact and harsh weathet conditions, rubber body of size width 400-500 mm, height50mm max at centre including fixing on road with appropriat adhesive and nails as per manufactures instruction complete all as specified and as directed. 39 S & F Stainless steel (Grade 304) hollow round or square pipe of any dia / size fixed as in posts / sheds / chair / railing and making frame structure as per design approved by AGE / GE for fixing sign board with knock - down fixing system & Top Mounted Round Baluster made of 38 to 50 mm dia Stainless steel 304 grade, channels, plates etc, including welding, grinding, buffing, polishing and making curvature ( wherever required ) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engr - in - Charge/ GE with and including making post holes or similar each n.exc 0.50 cum demolishing concrete and getting out, at least one / third height of poles / posts shall be embedded in PCC 1:2:4. The height of posts / poles shall be 1.5 to 2.5 mtr from ground level complete all as specified and directed. 40 S & F direction sign board of any size with 2mm thick aluminum composite panel comprising both side high intensity prismatic grade retro reflective sheeting as base and with cut out massage ( legends / borders letter / numerals etc) as directed with high intensity prismatic grade retro reflective sheeting both side site of boards with epoxy powder coating including fixed over framed work of stainless steel all as specified and directed by Engineer- in - charge/ GE. The follwing specification for sign board to be used :- (i) Paper used for printing should be 170 GSM 3M Reflective Vinyl.(ii) Printing of letter with Mutoh Eco Solvent.(iii) Base ofMaterial should be used should be 3mm Alcabond. 41 M&L forPlain Cement concrete in foundations, filling and mass concrete (1:3:6) typeC-2 using 40mm graded stone aggregate Complete all as specified and directed. 42 M&LPCC(1:2:4)type B-1(using12.5mmgraded stoneagggregate)asincoping,benchingof Drain, blocksforfixing of rungs andsimilar works including weathering, slightly rounded or chamferedanglesandthroating asdirected including necessary form work complete all as specified and as directed. 43 M & L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extracement, including forms, moulds, mitred / stopped ends etc complete all as specified and as directed. 44 Forming embankments including raising (or lowering) earth, spreading in layers n.exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and as directed. 45 EXTERNAL ELECTRIFICATION WORKS 46 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in hard/densde soil complete all as specified and as directed. 47 Excavating in trenches exceeding 1.5 m wide and exceeding 3.0 m in depth for foundation of poles, stays, laying of UG cable/ pipes & getting out in hard/densde soil complete all as specified and as directed. 48 Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 49 M & L for providing dry river sand as in sand cusioning for underground cable protection including punning down sand in layers complete all as specified & directed.Note: Only punned thickness of sand shall be considered for measurement purposes. 50 Supplying and laying common burnt clay sub class ‘B’ bricks of size 230 mm x 113 mm x 75 mm, laid perpendicular to axis of cable for protection of LT cables complete all as specified and directed. 51 Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc forprotection of cables complete all as specified and directed 52 Supplying and laying GI pipe Light grade (ISI marked) 80mm bore with connecting accessories, laid under road/ drain/fixed on wall etc forprotection of cables complete all as specified and directed 53 Supply install, testing and commissioning of transformer platform / plith mounted 100 KVA step down, Energy Efficiency level 3 outdoor type 11/0.433 KV, 50 HZ, AC double wound core type, copper wound, oil immersed, air naturality cooled with external cooling tubes, transformer delta connection on HT side and star connection LV side in accordance with vector sybol DyN-11 (vector group 4)with off load tap changer on HT side to vary secondary voltage +/-7.5% in equal step of 2.5%as per IS 1180 (Part-I 2014). The voltage regulation shall be as per IS including first fill of transformer oil upto appropriate level as per IS-335 all as specified and directed comprising with and including the following specification:-(i) 01 No of cable end box on HT side consisting of 03 Nos porcelain bushing with bushing brass rods, nuts, washers, & cable glands suitable for reception of HT 11000 V grade XLPE insulated heavy duty cables including glands complete.(ii) 01 Nos cable box on LT side consisting of 03 Nos porcelain bushing with bushing brass rods and nuts washers and cable glands of suitable for reception of LT 1100 votls grade XLPE insulated heavy duty including glands jointcomplete.(iii) Oil conservator with filter type drain valve and oil level guage.(iv) Explosion vent with double diaphragm & sight glass.(v) Thermometer pocket.(vi) Two Earthing Terminal on tank body to facilitate fixing of 32x6 GI strips.(vii) One No Thermometer dail type vapour pressure typ having range 0-120 degreecentigrade with maximum temperature indicator and re-setting device and marked maximum temperature reading pointed.(viii) Rating plate with terminal marking plate.(ix) Oil level guage.(x) Oil drain filter valve. 54 (xi) Oil filling port on top cover with plug.(xii) Air release valve/plug.(xiii) 04 Nos plain solid cast steel detachable rollers.(xiv) First fill of transformer oil confirming to relevant to IS and tested upto 60 KV dielectric strength.(xv) Inspection cover.(xvi) Silica gel breather without/with connecting pipe, first fill of dehdrating agent.(xvii) Cover lifting eyes.(xviii) Oil temp indicator of approved range, including shut off valve between conservator and main tank.(xix) Additional/ Extra bushing for neutral outside of LV side.(xx) The factory inspection is to be carried out by inspecting officer detailed by accepting officer.(xxi) PCC Plateform of size 2mtr width x 2 mtr length x 2.5 mtr height (height 1 mtr below the ground and 1.5 mtr above the ground) for mounting of transformer made up of PCC 1:2:4 using 20mm graded stone aggregate solid block and making all faces fare using extra cement as per manufacturer design of required length width and height including earth work complete. 55 Supplying and erecting steel tubular swaged poles complete with MSbase plate, finial taper plug, bolts, nuts & screws as per IS-2713 Part -II 1980 complete as specified, type 410 SP-55 (11.00 meters long) including painting with one coat of red oxide primer and two coats of aluminum paint on exposed surfaces & one coat of red oxide primer and two coats of bituminous paint for embedded portion complete all as specified and as directed. 56 M&L MS cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint complete all as directed. 57 M&L MS anti climbing device spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts washers and welding in two halves made to shape to suit the cross section of the pole complete all as directed. 58 M&L danger notice plate 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional scull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 25 x 20cm size. Complete all as directed. 59 M&L Switch Air break gang operated Trpple pole, mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating 200 amps, 11000 volts complete all as directed. 60 M&L lightening arrester high tension expulsion type complete with all fittings 11000 volts transmission class, discharge capacity 65 kilo amp. 61 Supply, laying & testing HT Cable XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) with aluminium Conductor, 11000 volts grade cross sectional area of size 95 Sqmm 3 Core Complete. 62 Supply and fix cable jointing kit for 11KV (earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 Sq mm. 63 Supply and fix cable jointing kit for 11KV (earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size95 Sq mm. 64 Supplying, laying, testing and Commissioning cable XLPE of size 95 sqmm 3.5 core insulated aluminium conductor, stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ polescomplete all as specified and directed.Note:- Excavation shall be measured and paid separately. 65 Supplying, laying, testing and Commissioning cable XLPE of size 70 sqmm 3.5 core insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ polescomplete all as specified and directed.Note:- Excavation shall be measured and paid separately. 66 Supplying, laying, testing and Commissioning cable XLPE of size 50 sqmm 3.5 core insulated aluminium conductor,stranded, armoured, PVC sheathed, LT 1100 volt grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ polescomplete all as specified and directed.Note:- Excavation shall be measured and paid separately. 67 Supply and fixing LED street light fitting 70 watt 230 volt AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as directed. 68 Supply and fixing street light bracket made up of 1.5 mtr light grade GI pipe 40mm bore bend to shape up to 120 degree angle including clamps nutbolts washer etc. 69 S&F FRP (fibre reienforce plastic) box of size 400x300x190 to suit the cable connections provided 4 pole connected for incoming and outgoing including support clamps fabricated from MS flat of size 25x6mm including nuts, bolts, wahsers welding, bending cold or hot, drilling holes for bolts in any shape or size including the two coat of aluminium paint over the one coat of red oxide primer and 4 pole connector 30amps capacity and SP MCB of 6 amps 02 Nos mounted on dinrail complete all as specified and as directed. 70 M & L for concealed sub main wiring using four run single core PVC insulated, unsheathed stranded copper conductor cable of size 2x1.5 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 1.5 Sqmm (green colour) as earth continuity conductor all as specified and directed.Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. 71 Supplying and erecting steel tubular swaged poles complete with MSbase plate, finial taper plug, bolts, nuts & screws as per IS-2713 Part -II 1980 complete as specified, type 410 SP-31(9.0 meters long) including painting with one coat of red oxide primer and two coats of aluminum paint on exposed surfaces & one coat of red oxide primer and two coats of bituminous paint for embedded portion complete all as specified and as directed. 72 Earthing complete with galvanisedearth plate electrode 60 cm x 60cmx 6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to GI earth lead wire 4.0 mm dia by means of boltsand nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber, MS funnel, wire gauge. CI cover with frame etc including necessary excavation in any type of strata, returning, fillingremoval of soil, filling ofcharcoal andsalt complete all as shown in electrical plate No. 5 of MES Sch Part I, connected to Earthing test point complete all as specified and as directed and testing on completion. 73 Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GIstrips of size 32 x 6 mm as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire mesh.CI cover with frame etc including necessary excavation in any type of strata, returning, fillingremoval of soil outside MD land ,filling ofcharcoal andsalt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to Earthing test point all as specified and directed on testing on completion. 74 M & L for Earth continuity conductor with GI strip 32 x 6mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. all as directed. 75 Supply, Install, Testing and Commissioning CPRI type tested, factory made,totally enclosed, IP 52 dust, weather and vermin proof, LTPanel outdoor type for 415V, 3 phase 4 wire, 50 Hz ACsystem made out of CRCA steel sheet 3.2 mm thick with TPN tinned Aluminium bus bar of rating 1.5 times that of controlling MCCB supported on F class DMC/FRP insulator with short circuit withstand capacity 21 MVA for 1 second, neutral bus bar of capacity of that of phase bus bar , general construction confirming to IS-8623/93, havingbottom base channel of MS section not less than 75mm x 75 mm x 6 mm, entire panel having common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size ( minimum 1.5 Sqmm)PVC insulated copper conductor cable , cable alleys, cable gland plates in two half includingLED indicatinglamp for all phasesand ,mounted on suitable PCC foundation for the complete panel base with following detailed specification,control and accessories complete:-(a)MCCB 4 pole 160 Amps, fixed thermal and magnetic setting, Ics=100%Icu, 35 KA, 50 Hz (for incoming) - 01 No(b) MCCB 4 pole 63 Amps,16 KA, 50 Hz - 04 nos (O/G)(c)Digital Multifunction meter withselector switch and three current transformers of suitable ratio and capacity - 01 Set(d) Indicating lamp for three phase - 03 Nos 76 Supply and install timer panel of capacity 12 KW 3 phase 415 volts with astronomical switch confirm to IS/IEC 61439 & 60529 IP 54 wiring with FRLS wires in built short circuit protection with class H insulation with 63 amps TPN MCB as incomer complete all as specified and as directed. 77 DG SET WORK 78 Supply, installation, testing and commissioning of diesel engine driven generating set, silent, with built in acoustic encloser, water cooled including AMF panel for standby power supply 415 volts, 03 phase, 4 wire, 50 cycles / sec, 100 KVA (80 KW or next nearest higher capacity) at 0.8 power factor complete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter, fuel tank capacity not less than 08 hours fuel requirement & battery as per OEM, battery leads, sound proof canpoy etc. with features for automatic shutdown in the even of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & microprocessor based genest with the following under mentioned features & all as specified & as directed including following specifications:- a) Alphanumeric LCD display with LED backlight.b) Operator interface.c) Suitable to provide a record of most recent fault condition & fault history.d) Complete alternator dat viz, voltage ph- ph, ph - netural, KVA, frequency etc.e) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc.f) Control including provn of service adjustment & calibration of DG Set control function.g) DG Set shall be in compliance with latest CPCB Norms as applicable on date. 79 (A) GENSET SPECIFICATION:PRIMEMOVER RATING : 100 KVA/80 KWNO OF PHASE: 03POWER FACTOR : 0.8 (LAG)CURRENT RATING: 139.12 Amps(B) ENGINE SPECIFICATIONType - Four strokeCOOLING: WATER COOLEDASPIRATION: TURBO-CHARGEDNO OF CYLINDERS : 06, IN- LINERPM: 1500GOVERNOR : MECHANICAL(C) ALTERNATOR SPECIFICATION:VOLTAGE:415RPM/FREQUENCY: 1500/50 HZENCLOSURE : IP 23VOLTAGE REGULATION (MAX) : +/-1 %INSULATION CLASS : H CLASS(D) CONFORMANCE STANDARDS:IS 4722, BS 5000, IS 1460, ISO 8528, BS 5514, ISO 3046.(E) MAKE OF ENGINE: CUMMINS/ KIRLOSKAR GREEN/ ASHOK LYLAND(F) MAKE OF ALTERNATOR : STAMFORD/ KIRLOSKAR ELECTRIC, CROMPTON GREEVES MAKE OF BATTERY : EXIDE/ AMCO/AMRON(G) Size/type/Number of battery : As per manufacture (OEM) recommendation. 80 (H) AMF PANEL SPECIFICATION :(i) SEB I/C: MCCB 4 P (Ics = 100% Icu) with thermal magnetic release, adjustable short circuit and adjustable overload setting having breaking capacity 50/65 KA of rating 200 Amps-01 Nos(ii) DG I/C : MCCB 4P (Ics=100% Icu) with thermal magnetic release adjustable short circuit and adjustale overload setting having breaking capacity 36 KA of rating 200 Amps-01 Nos.(iii) AMF O/G : MCCB 4P (Ics=100% Icu) with thermal magnetic release adjustable short circuit and adjustale overload setting having breaking capacity 36 KA of rating 200 Amps-01 Nos.The sizing / rating of all the connected accessories viz. Contactors, relays, timers, bus bars, connecting cables etc., of the AMF panel shall be in confirmity with I/C & O/G MCCBsNote: 1) Design / drawing of the AMF ofpanel & DG Set showing the dimension is to be obtained from DG Set/ panel board manufacturer/ supplier & is to be got approved from Engr-in-charge/GE before placing final order to the manufacture.2) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz.. Voltage, Current, KW KVA Power factor, frequency etc can be done for both SEB mains & DG mains.3) The cost of servicing including minor repairs/replacement such as topping up of coolant, engine/lub oil, dieselas well as lub-oil filters including periodical checking of the complete DG Set & AMF panel for the complete defect liability periods as & when required is deemed to be included in the quoted rates. 81 4) Anything missed out in the technical specification buttechnically required for efficient working of DG Sets is deemed to be included in the quoted rates.5) The quoted rate shall be deemed to be inclusive of first fill of engine oil & final sucessful acceptance test.6) The quoted rate shall be deemed to be inclusive of 12 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer: all testing arrangements/ equipments, resistive load including POL shall be made available by the contractor.7) The DG Set shall be supplied by the contractor after overall progress of main work of approximate 85%.(J) PCC Plateform of size 4.85 mtr length x 2.7 mtr length x 0.9 mtr height (height 0.3 mtr below the ground and 0.6 mtr above the ground) for mounting of transformer made up of PCC 1:2:4 using 20mm graded stone aggregate solid block and making all faces fare using extra cement as per manufacturer design of required length width and height including earth work complete.
Contract Date: Mar 17, 2026 Contract Value : 18.39 Crore
Statutory Bodies & Commissions/Committees No of Bidders 19
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 98,066
Government Departments No of Bidders 5
31.
Defence #9600097 Technical Bid
Tender For Invitation Of Online Bids For Iir Seeker On Board Inel Active And Passive Components => Limited; 1 Automotive DDR4 SDRAM 2 3.75KV RMS, Dual channel LVDS gigabit Isolator 3 3.75KV RMS, Dual channel LVDS gigabit Isolator 4 High speed differential line driver and receiver 5 1KV RMS Six channel digital Isolator 6 1KV RMS Six channel digital Isolator 7 Low power, Robust-EMC bidirectional digital Isolator 8 Switching Voltage regulator, 5.5V input, 2A step down module with integrated inductor 9 Synchronous SWIFT buck convertor with adaptive internal compensation 10 High density, synchronous buck DC/DC power module with enhanced HotRod 11 High efficiency step-down convertor Micro Sip power module with integrated inductor 12 2.4V to 5.5V, 4A/6A step down power module with integrated inductor 13 Synchronous buck power module with extended temperature range & enhanced Hot-rod 14 CMOS Voltage reference 15 High immunity ethernet physical layer transceiver with copper & fiber interface 16 Audio/Signal Transformer 17 High performance general purpose clock buffer 18 Octal buffer/driver with 3-state output 19 500mA ultra-low-dropout regulator 20 Low power, Precision FET Input Quad buffer 21 Octal 16 bit , 200ksps/Ch ADC 22 High efficiency and low IQ Buck converter module in a micro sip package with an integrated inductor 23 High-speed, robust EMC, reinforced six-channel digital isolators 24 1KV RMS , Six channel Digital isolators 25 High-speed, robust EMC, reinforced six-channel digital isolators 26 2kVAC Isolated uModule DC/DC converter 27 1KV RMS , Quad channel Digital isolators 28 16Mbps, 2.5KV Isolated RS-485 Transceiver 29 Quadruple Bus buffer gate with 3-state outputs 30 3.3V Hex Schmitt trigger inverter 31 Low Noise, Wide bandwidth, Low -Dropout 1-A Linear Regulator 32 High efficiency and low IQ Buck converter module in a micro sip package with an integrated inductor 33 3 Pin Microprocessor Reset Circuits 34 Dual inverter gate 35 3W fully regulated DC/DC converters 36 Serial Configuration Device 37 1KV RMS , Dual channel Digital isolators 38 16-Bit, 8 channel 250kSPS ADC 39 Ultra precision, Low Noise, 2.048V Voltage reference 40 Dual high speed differential line driver 41 Single 2 input- AND Gate 42 Ultra-low power, 32.768 KHz MEMS TCXO 43 Schottky diode & Rectifier 44 499ohm,±1%, 0201 Package 45 1Kohm, ±1%, 0201 Package 46 200Kohm, ±1%, 0201 Package 47 0.01uF,16V, 0201 Package 48 1uF,6.3V, 0201 Package 49 10uF,6.3V, 0402 Package 50 2.2uF,50V, 0603 Package 51 4.7uF,16V, 0805 Package 52 10uF,16V, 0805 Package 53 10uF,35V, 0805 Package 54 100uF,6.3V, 0805 Package 55 4.7uF,50V, 1206 Package 56 26ohm,±25%, 0603 Package 57 0ohm, ±1%, 0201 Package 58 Shielded Power Inductor, 470nH, ±20% 59 Dual core Arm Cortex based processing system & programmable logic 60 47uF,10V, 0805 Package 61 Synchronous/ Asynchronous NAND Flash memory 62 Precision miniature MEMS inertial measurement unit 63 402ohm,±1%, 0402 Package 64 75ohm, ±1%, 0805 Package 65 1uF,16V, 0603 Package 66 22uF,16V, 1206 Package 67 Cyclone 10 LP FPGA 68 Serial NOR Flash memory 69 Optically isolated short circuit protected relay 70 Octal 16-bit + 10V V out soft span DACs with 10ppm/deg C 71 Precision inertial measurement unit 72 Synchronous/ Asynchronous NOR Flash memory
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 6
32.
Defence #9545191 AOC
Tender For Provision Of Solar Power Plant At Sevoke Mil Station Under Ge Sevoke Road.; 2 Design, procurement, erection, installation, testing and commisioning including connecting to local utility grid; Grid connected solar photovoltaic plant 0.8 MW output peak capacity with net billing arrangement including Solar Photovoltaic Modules,DC Cabling, Module Mounting Structures (suitable for ground mountingwith and including Soil Investigation as per OEM recommendation, RCC foundation framed structure and other connected civil work duly vetted by IIT / NIT), Array Combining Boxes, ACDB, DCDB, Lightining Protection of SPV modules and other accessories, String Inverter as Power Conditioning Unit, Weather Station and Data Monitoring system (SCADA) all as per detailed specifications given in tender documents, latest MNRE/SECI/NISE/IREDA guidelines and directions, meeting the Make in India (DCR), consisting of all requisite accessories (BOS-Balance of system) and including the following main components (NOTE : The work shall be executed directly by OEM only through contractor.) Item Continued as 1.01 to 1.45 3 (A) Photo Voltaic Module: Mono-crystalline Silicon Bifacial Solar Photovoltaic Modules of minimum 550 Wp(module power and number of modules to be selected according to available area), having cell efficiency more than 20% under standard conditions, form fill factor more than 0.76, plant performance ratio > 75%, made of high transmitivity glass front surface and it shall give high encapsulation gain (transmittance above 90% and bending less than 0.3%). The modules shall have the following features :(a) The electrical parameters of SPV modules under standard test condition of irradiance 1000W/sqm, AM 1.5 Spectrum and temp 25 degree Celsius shall be as under : (i) Max Peak Power Pmax : 550 Wp or more (ii) Voltage at Max Power : > 40 V (iii) Current at Pmax :> 10A 4 (iv) Short Circuit Current :> 12A (v) Open Circuit Voltage :> 47 V (vi) Module Efficiency : > 20%(b) Rated output of the modules shall have positive tolerance of 3-5% and no negative tolerance is allowed.(c) It shall perform satisfactorily in RH 85% with temperature up to +85 degree C and should withstand wind of 200 kmph on the surface of panel.(d) PV modules shall be warranted for their output peak watt capacity, and it shall not fall of its initialvalue below 90% in first 10 year end and 80% after the end of 25 years.(e) Each module shall have RFID tag encapsulated with solar cell bearing following details (i) Name of Manufacturer of SPV Module (ii) Name of Manufacturer of Solar Cell 5 (iii) Month and year of Manufacturing (separately for cell and module) (iv) Country of Origin (both cell and module) (v) Peak wattage, Im, Vm and fill factor of the module (vi) Date of year of obtaining IEC PV module qualification certificate including the test lab issuing IEC certificate. (vii) Unique serial no of model no of module (viii) IV curve of module(ix) Other relevant information on traceability of solar cells & modules(f) The temperature coefficient of power for the module shall not be more than 0.50% per degree Celsius.(g) The module must have bypass diode of suitable capacity.(h) PV module must confirm to latest edition of IEC 61215/ IS 14286. In addition the modules must confirm to IEC 61730 Part I and II for construction and testing & safety qualifications and confirming to IEC 62804 PID.(j) It shall also be in conformity to latest minimum technical specification issued by MNRE/IREDA/SECI/NISE/ALMM from time to time. Modules should be of MNRE/IREDA/SECI/NISE/ALMM approved companies and as per latest IEC/IS standards. 6 (k) RFID reader is to be provided by contractor(l) Both PV cells and SPV modules shall be made in India (DCR).(m) Each structure should have angle of inclination as per the site conditions to generate maximum power. However, to accommodate more capacity the angle inclination may be reduced to 10 - 13 Degree until the plant meets the specified performance ratio requirements.(n) Fire Points with Fire extinguisher liquefied CO2 gas of capacity 10 kg and adequate qty confirming to relevant IS or ISI mark complete as recommended by manufacturer deemed to be included in the unit rate quoted.(o) Danger Board and Rubber mat as recommended by manufacturer deemed to be included in the unit rate quoted.(p) S&F Pressure Booster pump electrically operated with minimum 3 HP 02 Nos (Running+ standby) three Phase AC Supply motor and having head not less than 20 mtr, including PCC foundation civil wokrs and necessary cable required for connection in drawn in PVC conduit heavy duty/ DWC/Electrode pipe from existing nearest point to the motor starter panel including motor starter suitable capacity,PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm/50 mm/32 mm/25 mm inner dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brass threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches with necessary exavation, removing and returning filling work and including all accessories from the new PVC tank cap 10000 Ltrs install at proposed site for cleaning of entire solar power plant system.(q) SPV Panel is to be fixed in such a way that lower portion of the Panel remains atleast above 1.5 mtr of finished reflecting surface and cost deemed to be included in the quoted rates. 7 (B) Junction Boxes: Junction boxes of suitable Nos (as per design)/OEM recommendations inputs and suitably rated out put having separate DCfuses for both (+)&(-) on input and isolator on output terminal for each string.Each junction box must have as pare input terminal.The junction boxes shall be dust and vermin proof and water proof made of FRP/ Thermo Plast with IP 65 protection in compliance with IEC 62208 and shall be UV resistant, fire retardant. It shall have surge protection and maintenance free earthing as per relevant standard. The junction box shall have suitable arrangement of the following: (a) The strings are required to be connected to the copper bus bar through individual fuses. (b) Provide arrangement for disconnection (DC dis-connection switch) for each SJB/ SCB. (c) To provide a test point for each sub group for quick fault location and to provide group array isolation. (d) Each array box shall be of relevant IEC standard. (e) Each array junction box shall have suitable bypass & reverse blocking diodes for minimum DC blocking voltage of 1000V with suitable arrangement of its connection. Reverse blocking and bypass diodes shall work for extreme temperatures and shall have efficiency of 99.98% confirmed by appropriate IEC standard. 8 (C) DC Cables: Suitable size of XLPE insulated tinned Copper cable (min 10 sqmm) of solar grade, 1100 Volts and UV resistant for outdoor installations confirming to IEC : 60227/15694 & 60502/ IS : 1554 (Pt I&II)) and shall be as under : (a) All cables and connectors must be as per IS/IEC standards and shall be able to withstand harsh environmental conditions including high temperature, UV radiations, rain, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS. (b) All the cables / wires shall be provided with UV resistant printed ferrules for DC wires. (c) The size of the cable shall be such that average voltage drop at full power from PV module to inverter shall be less than 1.5%. (d) Cable batch No., Drum No, IS code and size and make shall be mentioned on every one meter or as per OEM practice. (e) The wiring of the module interconnection shall be in UPVC/HDPE pipe of suitable size. (f) The cost of interconnecting DC Copper cable, MS cable trays, MS cable trays suitable to accommodate Solar grade cables from SPV module to inverter are included in the item. 9 (g) Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain ant type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes, exavation, removing, return filing, channel, any type of metal work is not measured and paid separately under relevant items.(D) Module Mounting Structure (MMS) (Suitable for ground mounting on any type of soil condition) :Design, procure, fixing, support structure made of hot dipped galvanised steel with min 85 micron thickness including necessary PCC / RCC foundation and associated work (cutting, grounding, PCC filling, disposing waste material,etc., complete) and fixing mounting arrangement suitable for SPV modules so as it can with stand wind speed of 170 km per hour & minimum yield strength off 250 MPa. The mounting structure is to be installed on ground. Mounting structures to be so designed that maximum load is directly on ground. It shall also observe minimum space without sacrificing the out put of SPV panels & adequate spacing between the arrays shall be available for easy cleaning and maintenance. Nuts, bolts, protected from the atmosphere and weather mounting structure shall have to be adequately of Stainless Steel of grade SS316. 10 NOTES :- (a) Two numbers of anti theft fasteners of Stainless Steel on two diagonally opposite corners of each module shall be provided. (b) Module mounting structure shall be fitted to provide maximum generation. (c) MMS design shall be supported with Staddpro Report vetted by Third Party (Gov Institute) and submitted for the approval of the Accepting Officer. (d) The height of approved design MMS for solar power plant shall be as per latest MNRE/IREDA/SECI/ NISE guidelines. (e)Minimum grade of RCC M-25, design mix (using 20mm graded crushed stone aggregate includingTMT bar as per design, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and other connected works as per design and OEM recommendation. Civil work shall be designed through approved consultant of MES as per latest MNRE/IREDA/SECI/ NISE guidelines and vetted by IIT / NIT.(E) Lightning Protection forentire Solar Power Plant (i.e PV Array, Inverter etc) : Design, procure and fix lighting arrestor system confirming toIS/ IEC-62305(Part1-4)on the ground. The air terminal shall be fixed at the top of MS pole with base so as to beat least two meter above the pole to be protected. Its height above 9 mtr level shall be depend upon the level of protection and protection radii required. 11 NOTES :-(i) The cost of all equipments, MS Pole, Copper strip upto earth test point,LA, etc., shall be deemed to be included in this item. (ii) The cost of sufficient earthing for lightning protection is also included in this item to be provided by Engr-in-charge. and no extra payment will be made to the contractor on this account (iii) The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account. In case of any dispute, decision of Engr in charge will be final, conclusive and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474). Earth resistance shall not be more than 3 Ohms. (iv)Separate LA arrangement & the design document of the same shall also be submitted. (v) The protection against induced high voltage shall be provided by the use of metal oxide varistors and suitable earthing such that induced transient find and alternate route to earth. (vI) SPV Power Plant shall be provided with lightening and over voltage protection. (vii) Internal surge protection shall consist of three MOV type surge-arrestors connected from +ve abd +ve terminals to earth (via Y arrangement) 12 (F)Power Conditioning Unit: Procure, fixing, testing and commissioning of minimum 4 (Four) unitswith overall not less than 800 KW output on 11 KV AC supply, Solar-power inverter suitable for without DC power of Solar PV module/ array with AC output further feeding to grid confirming to IEC:61683 for efficiency, IEC:62109-1 or equivalent for safety and IEC:62093 for reliability. The input DC & output AC technical specification of Inverter are as under :Input (DC) (a) Max Absolute DC input Voltage : 1000 V (b) Start-up DC input voltage : 200 - 500 V (Default 420V) (c) Operating input DC voltage range : 200 - 1000 V (d) No of independent MPPT : One (e) MPPT input DC voltage range at Pacr : 180 - 1000 V DC (f) Max input DC Current : As per design. (g) AC grid connection type : 3Phase (4W + PE) (h) AC output power : As per design. (j) Max AC output Apperant power : As per design. (k) Max AC output Current : As per design. (l) Max AC fault current : As per design. 13 (m) Nominal Output Voltage : 800 Volts AC 3phase or as per the design of Solar Stepup Transformer (n) Output voltage range :± 10% (o) Output Frequency : 50 Hz ± 3Hz (p) Power factor : > 0.99 (q) Harmonic Distortion Current : < 3% (r) Efficiency : > 98% (s) Standby operation consumption : < 1.5 W(t) Operating temperature upto 85 degree centigrade (u) The Copper based inverter shall have minimum IP-67 protection, ground fault monitoring, reverse polarity protection, anti-islanding, DC reverse polarity, AC and DC short circuit current and over current, AC and DC over voltage and over temperature. 14 (v) The inverter shall adjust voltage and frequency levels to suit the grid. (w) The inverter shall be self commulated with Pulse Width Modulation (PWM) technology and shall be capable of synchronise maximum with in one min. (x) Maximum Power Point Tracker (MPPT) confirming to IEC 62093 shall be integrated in the inverter to maximise the energy drawn from the PV array (y) Monolithic design of inverter is not permitted. (z) Shall have anti-Islanding features. (aa) The inverter shall have suitble nos of protected inputs (asper design) and outgoing shall be protected by ACB/MCCB. (ab) The inverter should have MODBUS, PROFIBUS, ETHERNET common ports. (ac)The inverte rshall include appropriate self protection and self diagnostic features to protect itself and the PV array fromthedamageintheeventof invertercomponent failureor fromparametersbeyondtheinverterssafeoperatingduetointernaland/orexternalcauses. Invertershallhaveprotectionarrangementagainst ground leakage faults, over voltage, (SPD) & over current. Inverter shall have arrangement for adjustment for adjusting DC input current and shall trip against sustainable fault down stream and shall not restart till fault is rectified. (ad) The inverter should have provisions of Galvanic isolation, anti-islanding protection (IEEE 1547/UL 1741) equivalent IS and lightening. (ae) PCU must have the feature to work in tandem with other similar PCUs and be able to be successively switched ON and OFF automatically based on solar radiation variations during the day. (af) Minimum Warranty of Inverter- 12(Twelve) Years and defect liability period deemed to amended accordingly for the said item. 15 (G)ACDB : Outdoor type powder coated weather proof,vermin proof made out of CRCA sheet front open able door, lockingarrangement, including suitable working space in DCDB busbar chamber, cable box chamber including Copper busbar of designed capacity /bus raisers suitable capacities with PVC sleeves/tape RYB colour for phases identification, including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-65 and fixed on wall / floor with control wiring with comprising cable gland brass, copper lugs etc. and comprising the following as per design :- (i) MCCB 4Pmicroprocessor based for outgoing (ii) MCCB 4Pmicroprocessor based for incoming (iii) AC type 2 Surge Protection Device (iv) Spreader Terminals as per requirement (v) Multifunction meter (vi) CT of suitable ratio(vii) Copper busbar chamber (ix) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 16 (H) DCDB:- Outdoor type powder coated, weather proof, dust proof,vermin proof made out in CRCA sheet front open able door, looking arrangement, including suitable working space in DCDB busbar chamber,cable box chamber including copper bus raisers with PVC sleeves/ tape RYB coloursfor phase identification, including all bus raiser shall be extend upto cable box chamber, confirming to IP-65 and fixed on wall /floor with contral wiring with comprising cable gland brass, copper lugs etc. (i) MCCB as per requirement (ii) Fuse as per requirement (iii) Copper busbar chamber. (I) Weather Monitoring System Pyranometer : The pyranometer (ISO 9060 classification ) alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specifications of the pyranometer shall be as follows :- (i) Spectral response : 031 to 2.8 micron,(ii) Time response (95%). Max 15 second 17 (iii)Nonlinearity + 0.5% (iv) Temperature response : - 2%(v) Tilt error <+/- 0.5% (vi)Zero offset themal radiation +7W/Sqm (vii) Zero offset temperature change + 2 W/Sqm(viii) Operating temperature range - O °C to 80°C(ix) Non stabillity Maximum - 0.8%,(x) Resolution minimum +/-1 W/Sqm (xi)Output Analog 4.50mA (xii) Digital RS 485(xiii) The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 18 (J)Balance of System(BOS) Items/ Components:TheBOSitems/componentsof theSPVpowerplants/systems deployed under this project shall conform to the latest edition with certificate of IEC or equivalent BIS Standards/MNRE specifications/ as specified in Para 1.01 of Minimal Technical Requirements/ Standards for SPV System/Plants to be deployed during this financial year under the programmes of MNRE available on MNRE website as on last date of quoting of tender. Notes:(i) The contractor must visit the site before quoting the rates for this item to assess the site condition so as to decide up on location and layout of SPV, placement of inverter, length of DC cables, lightning arresters, etc., complete. (ii) The contractor shall submit complete scheme including electrical diagram of the work, schematic diagram, SPV module layout, placement of LAs, Civil work, etc., complete as per IREDA/ SECI/NISE/MNRE/ALMM latest guidelines as applicable, Relevant IEC/IS norms to the GE for approval with in one month of date of commencement of the work. (iii) The rate quoted is deemed to be inclusive of the all protection system including surge, lightning arresters and necessary earthing all as specified and directed. 19 (K) Remote monitoring system (SCADA) for solar power plant complete with all electronic andelectricial partswith andincluding all necessary software and hardware etc to make fully functional connected to LED monitor (55 inches) with complete plant parameters as required and operate the system from remote and Other Accessories includingandThe system will be controlled from the main control room where all the data from different parts of the plant shallbe received, analyzed and action taken either manually or on auto as per the system design by OEM . The SCADA shallhave remote monitoring capability comprising with the following Items and with and including all connectedaccessories as per OEM recommendation complete:(a) Main SCADA control wall mounting panel complete with fixing arragnment like nut bolt, washers suitable size and connected items. (b) LED Moniter (55. inches) with mouse, key board, CPU (Minimum 1 TB storage alongwith 12 GB RAM, i7 processor), key pad and single phaseUPS 10 KVA with 12 Volt battery, 14400 Ah battery bank with rack and required battery backup should not be less than 4 Hrs inside control room.(c)“SCADA System shall be audited for Cyber Security by CERT certified firms at the time of commissioning. Subsequent cyber security audit shall be carried out after every 03 years and cost of audit and rectification shall be born by the contractor” 20 The Contractor shall provide following defined user access levels, unless otherwise instructed by the Engineer-in-Charge: -• Normal viewing only (default level) The default level shallpermit users to view al displays except those specifically assigned to a higher level of access.• Dally Access The daily access level shall allow viewing (ie default an printing at trend displays.• Operator Level (Remote Control) The operator level shall permit authorised users to access lower levels a and to carry out the following actions:- Perform control actions Acknowledge alarmsEnter or modify manually-entered data for inclusion in thereports.• Monthly and Yearly Data Archiving The level shall permit authorised users to access lower levels and shall provide the facility to download specific data to long ten data storage for archive purposes(d)The SCADA software shall be of a proven design and reliable, and conforming to industrial standards and shall: -• Support multiple makes of RTU/ Microprocessor controller/ transmitters and models and provide required software features needed to easily adapt a device whichshall not be supported as standard to the SCADA system. 21 • RTU/ PLC/ Microprocessor base controllers and transmitters shall have an expandable architecture and scalability to provide future capacity increases in SCADA system as well as meet present needs of the administration, provide multi-level security and password mechanisms to prevent use of the system by unauthorised persons. The access privilege of authorised users shall be defined separately and permission shall be provided to the users only to access areas concerning them, provide an on-line operatingenvironment.• Adding a new RTUI Microprocessor based Controller to the SCADA system or changing configuration of the existing RTUs/ Microprocessor based controller shall not result in stopping or hinder working order of SCADA system.• The Contractor shall specify maximum number of data which shall be achieved by the system without any performance loss. The Contractor shall conduct necessary tests to prove maximum number of data points achieved. The Contractor shall also be responsible to create additional data points necessary for conducting such tests. Any AutoCAD graphics shall be able to be converted to process diagrams and shall be re-loaded and operated after completion of all works and during tests.(e)The Contractor shall hand over to MES the SCADA and application software (as CDs or DVDs) necessary for re-loading software to the system in case of failures The CDs or DVDs shall be provided after making the necessary tests. The operating system ofrouters and work stations shall be of an architecture that provides a multi-tasking operating environment, and SCADA software shall also be multi-tasking. Therefore multiple tasks such as receiving measurement results from devices, displaying these results on computer screen. storing on a computer disk, sensing alarm conditions that may occur based on measurement results, and displaying them to users, generating reports from collected data, and printing them cut, transferring issued commands to Microprocessor controllers/ RTUs/ PLC, that SCADA software is supposed to execute shall be handled simultaneously without one task waiting for another. 22 To configureSCADA software or to change the system configuration, definitions shall be either defined directly by using a keyboard or another interactive tool or mechanisms that allow importing of configuration definitions from a text file created with a text editor. The database configuration shall be provided by means of an interactive program that contains menus or similar approaches and shall be easy to use The database configuration definition program, when required, shall be capable of extracting definitions related to the configuration from information created in text format to use as definitions for configuration The following shall be possible online without interruption or hindering of usual operations: -•Adding an RTU to the SCADA system.•Deleting an RTU from the SCADA system•Changing configuration information related to an existing RTU definition.•Modifying definitions in database containing information about measurement and control points.•Creating screen pictures which offer operators to monitor and control the SCADA system.•Similar configuration changes. 23 (f)SCADA software shall be upgradeable to new versions with an automatic mechanism to be provided by the Contractor. The old version of software shall be overwritten by new version without resulting in a change in any of the definitions created in previous version, nor disturbing the operational logic defined in previous version. Al! text being available on the screen shall be in English language The database shall be configured on-line when the SCADA system shall be in operation. The changes on existing definitions or new definitions related to database shall be made when the data collection n and control functions are being performed. The SCADA Software shall be operated using the database that shall be resident in the memory(g)Data Exchange The control system shall provide a method of real-time data exchange with different application programs like Geo Information System (GIS). relational database, third party spreadsheet packages, report generation and graphical simulation packages.(h) Historical Data Management An historical data management (HDM) system shall be provided for archive, storage and retrieval of operational data comprising field input data, manually-entered data and calculated points Archived historical data shall minimally include averages, minima and maxima for each analogue value compiled over hourly. daily and monthly time periods, with a minimum capacity of 1o00 points. The HDM system shall be capable of selectively increasing the rate of data capture based on events, such as process variable status, discrete inputs, or operator command. Minimum and-maximum data shall include the time and date of occurrence. Gaps in collected data caused by faulty instruments or control system equipment shall not be included in average). minimum and maximum compilations. 24 (j) Report GenerationThe system shall be provided with a report generator utility which shall enable authorised users to create, delete or modify report definitions The report definitions shall allow for retrieval of data from on-line database and farm historical data files and for formatting data for output to printer. The format of each report shall be definable by user to include the definition of static or background data, placement of data base values, number of significant digits of a value, date and time of report and calculated values(k)Graphic Display GenerationThe system shall be provided with an interactive on-screen graphic generation utility which shall allow an authorised user to create new graphic displays and modify or delete existing displays at any work station including those associated with the LCP/ outstations. The generation utility shall include an interactive linkage process allowing user to link symbolic, numeric and bar graph representations and data entry locations to dynamic data base variables. The graphic display system shall be capable of making full use of the VDU resolution in the composition and display of graphic information. Graphic symbols shall be definable by the user for display of static and dynamic data. The user shall be able to as5emble a library of symbols which shall be retrievable into any graphic display. Text and symbols shall be able to be enlarged, shrunk, moved, mirrored or related with reference to a given display. The system shall be able to represent dynamic analogue data on a graphic display as a variable-length, sizeable bar graph, as well as numeric text. 25 (l)DisplaysGeneral all displays, excepting those containing data derived from historical files, shall be completely displayed within two seconds of the operators request. Dynamic data shall be continuously updated while being displayed. All screen displays shall provide following displays which shall be fixed in their locations to normal operations:• Alarm banner window at bottom of the screen display showing last three highestpriority unaccepted alarms. Where the system allows contents of banner to be limited (eg by user name or group) then the selection criteria applied shall be displayed with the banner.• Main display area for user selected displays e.g. mimics, alarm lists, etc.• System dialogue banner window at bottom of the screen shall display relevant system information such as error message and user prompts 26 •A day, date and time indicator shall be able to show local time an alarm bannerarea shall be included on all displays which provide information regarding most resentalarm events. The system shall allow operator to obtain details of most recent alarm event from any operational screen display through direct operation using a maximum oftwo keystrokes or selections. The system shall allow the operator to obtain a print of any display, including graphics through use of a standard system command. Screen displays shall appear identical incorporated form Dynamic data contained on a display shall not change during screen print Such that a snapshot of conditions is portrayed. Each display shall include time of day in hoursminutes and seconds and date in day, month and year format.•A facility shall be provided which allows paging to related displays through the use of ‘page forward or backward keys, or through the use of pick points(m) Suitable size of HT & LT XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts and 1100 Volts grade with stranded aluminium / copper conductor of size as per OEM recommendation and approved design ISI markedincluding cable glands, lugs, jointing kit etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories and necessary earthwork, civil work deemed to be included in quoted rates of the above items.(n)Generic Displays.The system shall produce various generic displays automatically 27 Metering arrangements: (A)Suitable bi-directional metering arrangements with recording facility shall be provided as per the norms of WBSEDCL. The metering arrangements must have feature to measure and record, (i)Parameters of KW, KWh, KVAR, voltage, current, PF and any other metering required to determine efficiency and efficacy of the system. (B) LT 3 Phase 4 Wire Electronic Tri vector Meter with CT ratioshould be as per capacity of SPV plant. (i) Standard: IS 13779:1999 / CBIP 88 (ii) Accuracy: Class 0.5 (ii) The metering arrangement shall have inbuilt Solar PV Plant synchronisation features. (iii) Reference Voltage - 3x240 V (iv) Basic Current (Ib)- 5 A (v) Maximum continuous current (Imax) - 10 A (vi) Rated Frequency (variation) - 50Hz (±5%) 28 (vii) Power consumption:- Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (viii) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (ix) Display in the event of Power Failure: Internal battery back-up for LCD display (x)Communication port: Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is providedwith RS 485 for DLMS protocol (C) CT/PT operatedenergy meter with following features (i) True four quadrant metering (iii) Time and day metering with maximum demand registration and automatic billing (iv) LCD display with announciators for various critical events (v) Scroll lock feature for continuous display of a desired parameter on display (vi) High resolution energy display mode for dial test (vii) DLMS protocol for meter reading, with option to remote reading port. 29 (viii) Advanced event detection features for voltage, current and magnetic influence (ix) Meter reading in absence of mains, using internal battery. (x)Power Manager Device Nano type with 4 inverter support with energy monitoring, zero export control, Load Management having RS-485 communication port, ethernet including RS 485 cable core size 0.5-1.5 Sqmm to establish communication between inverters, SCADA and sensor as per OEM recommendation with and including all connectedaccessoriesdeemed to be included quoted rates.(xi) Digital WIND SPEED SENSOR withminimum 3 cup Anemometer range 0 to 70 Mtr/ Sec distance constant 2.5 Mtrs output TTL Pulses output proportional to wind speed and diameter of cup 50mm with brass housing and stainless stell shaft(xii) WIND DIRECTIONSENSOR with wind vane and sensing vain coupledto linear endlsess potentio meter IP 67, range 0-357degrees, operating temperature -40 to +60 degrees celsiuswith brass housing and stainless stell shaft and aluminium vane complete 30 (xiii) AIR TEMPERATURE SENSOR withRTD sensing element PT100 mounted inside a weather shield duly coated with weather proof reflective white paint , range -40 degree to +60 degree celsius with nylon body housingwith weather shield and brass stem to mount the sensor, includingpower requirment 5 Volt DC complete. (xiv) MODULE TEMPERATURE SENSOR Model PT 1000 measuring range -40 Degreeto + 80 Degree Celcius with suitable ouput as required and directed on site and mounting on RTD encapsulated in suitable housing including connecting cables as required complete.(xv)Tipping Bucket Rain Gauge with Magnet and Red Switch type Sensing, rim diameter 203 mm and collecting are 335 MM SQ, Rain gauge shell made up of FRP bucket and mounting made up of stainless steel SS316 and unlimted capacity,including connecting cables as required complete.(xvi)SOLAR Radition Sensor ARN 8101 with 72 element thermo pile sensor and spectral range 0.3 to 3 Micro Mtrs and sensitivity 20 Micro Volt/ W/M², range 0 to 1500W/SQM & output 0 to 25 milli Volt and operating temp -10 to 70 Degree Celsiusincluding connecting cables as required complete with all fixing arrangment and necessary civil work complete with including all connectedaccessories as per OEM recommendation/Designcomplete: 31 (L)Step up solar transformer (800 volt/11 KV)” - Design,procure,erection, installation, testing and commisioning including connecting to local utility grid :Oil filled Type 3 phase, 50 Hz, ONAN cooling type, vector group of appropriatetype, number of load voltage Ratio: number of Phases / Freq.: 3 Phase / 50 Hz., Sealed type Copper wound Transformer with Off Load Tap Changing Arrangement on HV side in steps of 2.5% , +5% to -10% having cable end boxes on HV side suitable for 3 Crore X 300 Sq. mm. XLPE cable of 11 kV grade on HT side and LV side complete with all accessories like buchholz relay, Oil temperature indication, winding temperature indication and alarm etc preferbly DMCR Protection Relay i/c first filling of filtered dehydrated K Class natural Ester Oil bioTransol (as per IS 16659) and confirming to IS 1180 and losses shall be as energyefficiency Level 3 only & 100% load phase, with an impedence of 6.25% i/c as per specification below complete in all respects as required at site. Design ambient to be considered as 50 Deg C.All the balance parameter like temp rise, Basic insulation level, flux density etc shall be strictly in accordance with IS 1180 Part - 1 only including necessary earth work, PCC plinth foundation etc.Heat Run Test is the mandotary test for each Transformer.Standard: The equipment shall conform to the latest edition of applicable standards as follows. In case of conflict between applicable standards and this specification, this specification shall govern.• IS 2026 Standard for Oil filled Transformer• IS:3639 for Fittings and Accessories• IS:2099 for Bushings > 1000 V• IS:7421 for Bushings < 1000 V• IS:1271 for Electrical Insulation classified by Thermal stability• IEC 62770 Natural Ester Oil• CBIP Guidelines 32 (xvii) CORE : Transformer shall be double wound, core type with low loss, non-ageing, high permeability PRIMEGRADE, CRGO with M4 Grade or Better, perfectly insulated and clamped to minimize noise and vibrations. Followings should be Mandatory for any manufacturer: -(a) Transformer shall be of BOLTLESS core design.(b) Core shall be purchased Directly from Manufacturer or from their accreditedMarketingorganization of Repute & not through any agent. Bidder has to submit manufacturer’s name during bidding having sufficient credential & Core has to be purchased from the approved manufacturer.(c) Stage inspection of the core shall be done at manufacturer’s premises & inspection call shall be given with following Documents: (i) Invoice of the supplier (ii) Mill’s test certificate (iii) Packing list (iv) Bill of landing & Bill of Entry certificate by customs(d) Transformer manufacturer should have in-house core cutting facilities for proper control & monitoring of quality & to avoid mixing of Prime core with Second grade /defective core materials. Transformer Manufacturer should have in-house slitting Machine so that core is cut to width & stacked with minimum air gap thus ensuring Burr level less than 10Microns.(e) Core shall be procured from one of these reputed Manufacturers : Posco / Nippon/ Novex/ Ak Steels.(f) The insulation structure for the core to bolts and core to clamp plates shall be such as to withstand a voltage of 2000V for one minute. 33 (xviii)Tank:Tank should be of corrugated wall construction type. The exterior of tank and other steel surfaces exposed to the weather shall be thoroughly cleaned and have a priming coat of zinc chromate applied. The second coat shall be of an oil and weather-resistant nature, preferably of distinct colour from the prime and finish coats. The final coat shall be of a flossy, oil and weather resisting non-fading paint of specified shade. The interior of the tank shall be cleaned by shot blasting and painting with two coats of heat resistant and oil insoluble paint.Winding:(a) Winding shall be made with 99.9% pure electrolytic grade copper, insulated with thermally upgraded paper (Insulation Class A / Conductor Turn Insulation-Class E).The HV & LV winding should be able withstand thermal and mechanical stress in the event of short circuit.(b)Winding shall be carried in dust free area(c) The completed core and coil assembly shall be dried in vacuum and shall be immediately impregnated with oil after the drying process to ensure elimination of air and moisture within the insulation.Oil type: TransformerTransformer oil shall be as per IS-335:1993. It shall be natural/synthetic ester oil. The material safety Data Sheets (MSDS) for the Transformer oil shall be submitted by the bidder along with the offer Temperature Indicator:One set of winding temperature indicators with necessary current transformer, heating coil and a detector element and one set of oil temperature indicator with maximum reading pointer shall be mounted locally so as to be readable at a standing height from ground level. Each of the above indicators shall be provided with necessary contacts for alarm and trip: (a) Oil Insulation class : K class. It should also exhibit safety against fire hazards 34 (b) Cooling : ONAN(c) Vector Group: to be decided during design.(d) Percentage Impedance (Z%) 6.25 %.(e) Transformer Losses:as per IS 1180 - Level 1(2021)(f) Taps on HV for HV variation : +5 to -10 % in steps of 2.5% each (g) Termination (HV): Cable End box for11 KV cableof suitable size(h) Termination (LV): Cable connection(j) The transformer shall be supplied with following fittings:(k) Lifting lugs and Jack lifting pad support(l) Earthing terminals - to be decided during design. 35 (M)Earthing :The complete system shall include chemical earthing of required quantity for step-up Transformer (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes and for LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines.No separate cost of the same is included in the schedule and amount will be paid to the contractor on this account in case of any dispute decision of Engr in charge will be final and binding to contractor. (The earthing shall be of copper earth plate and having specification as per SSR Item Sr 19474).Earth resistance shall not be more than 3 Ohms. 36 IMPORTANT NOTE FOR SOLAR POWER PLANT CONTRACT (COST DEEMED TO BE INCLUDED IN QUOTED RATES :-(1) The item specification and details given are for guidance purposes only and are likely to vary with modified / higher specification than that specified in the BoQ based on detailed site survey, solar potential assessment, design approval etc keeping the quantity of Solar inverter (PCU) and Solar Transformer same as in the BoQ. The items as per the finalized and approved design and specification, including make, shall be provided by the contractor without any extra cost to the department. All makes should be as per the latest MNRE approved list of makes and models.2.Cost of preparation of DPR design vetting from NISE/MNRE approved Institute and net billing arrangement (as per WBSEDCL) is deemed to be included in the quoted rate.3.The contractor shall submit complete design of Solar power plant, Schemetic/line drawings, detailed mounting structure array layout drawings alongwith SBC report based on the soil investigation as per OEM recommendation, Single line diagram with and including project reportand connected document shall be submitted by OEM through contractor prior to commencement of the work for approval of Accepting officer and subject to the drawing and designduly vetted by IIT/NIT (for mounting structure only) and vetted by NISE/ SECIfor entire scheme of Solar Power GenerationProject including evacuation and Net Metering arrangement complete before recommendation by GE for approval of the accepting Officer. 37 (i) The scope of works involves engineering, procurement & construction (EPC) of entire Solar Power Plant of capacity 0.8 MWp.4. The entire work shall be executed directly by OEMonly through contractor and contractor has to submit the MoU with OEM (agreement period for 25 years of entire Solar Power Plant Project) prior to commencement of work and same shall be approved byGE. 5. Boring of holes under road, pavement, hard standing by trenchless technology (HDD) GI protection pipe up to 100 mm bore (dia), maximum 2.5 metre below of apron areain any type of soilcomplete.Note : (i) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (ii) Any damage to existing cables any type and pipe line in the way of drilling the bore have to berepaired and made good by the contractor within 24 hours. No extra cost will be paid in this account. (iii) Contractor has to get the survey of route, length and depth for boring before quoting the rate. (iv) Connected items like HDPE/PPR/DWCPE pipes for entire Solar Power Plant Project, exavation, removing, return filing, channel, any type of metal work is deemed to be included in the quoted rate. 38 6.Cost of comprehensive maintenance as per OEM recommendation alongwith cost of spare parts required during 5 years of defect liabilty period after completion of Ph-I is deemed to be included in the quoted rate.7. Bidders attention is drawn to pre-bid conferance with department and also visit the site prior to bidding and other factor required as per OEM recommendation deemed to be included in quoted rates.8. The contractor has to carryout Pre-commissioning test of solar power plant including stepup transformer by CEI/SEI. The necessary tools and plants required for inspection of the plant shall be arranged by the contractor.and costsare inclusive in quoted rates.9. Contractor needs to know the irradiance of the location at the project before quoting. The contractor will design DCR (Make in India) for entire Solar Power Plant according to irradiance of the project location and efficiency of the components to produce the desired peak value as mentioned in the schedule i.e. 800 KW output on 11 KV AC supply and inject to the proposed RMU 11 KV. 10. During the execution of work any type of damage by elephant or monkey manance, contractor is fully responsible for protection of all solar power plant equipments including connected items i.e. PV Module, Inverter etc. No claim will be sought from the department. 39 11. All SCADA related activities viz. cables till SMBS and inverter and the requisite software and hardwarefor control room shall be included in the quoted rate.12. Vegetation Growth should be controlled by use of Deweeding Chemicals deemed to be included in Quoted Rates.13. Adequate Water Storage Facility of capacity 10000 Ltrs PVC Tank 5 Layer (with guarantee of 10 years after physical completion of work) on PCC Platform including suitable foundation for cleaning of PV Modules and suitable water drainage facilitiesfor both (Rain Water and Cleaning Water) from proposed site to existing drainage chamber is deemed to be included in the quoted rate.14. Solar Transformer fed from the Inverter should not be having odd harmonics (certificate needs to be required before physical completion of work).15.The Shutdown duration of Inverter should be monitored and recorded and analyzed. 40 16. The SPV Power Plant will be capable of generating 800 kW AC Output atleast once in a year and the AC Output of the plant will be not less than 90% of initial output by the end of 10 yearsand not less than 80% of the initial output by the end of 25 years.17. The Contractor shall operate and maintain Fire Protection System and safety equipments for the entire Solar Power Plant for 10 Years and cost of the spare is deemed to be included in the quoted rates.18.The firefighting system for the proposed power plant for fire protection shall be consisting of:a) Portable fire extinguishers in the control room for fire caused by electrical short circuitsb) Sand buckets in the control roomc) The installation of Fire Extinguishers should conform to TAC regulations and BIS standards. The fire extinguishers shall be provided for control room housing, PV array installation.19.Solar Components shall not be connected to LAN, WAN, or any Internal Data/OPS nw. 41 20.Sys with Bluetooth, GSM, Wi-Fi, or any Telemetry features should be avoided, unless explicitly cleared monitored.21. Finalization Of Feasibility Report, Design, Engineering, Transportation, Storage, Insurance, Civil Works, Erection, Testing & Commissioning etc., ensuring net-billing as per state net billing policy, quality control of grid connected.22.The Comprehensive Maintenance of SPV Plant would include wear, tear, overhauling, machine breakdown, insurance and replacement of defective modules, Inverters/PCU, spares, consumables & other partsas pe OEM reocmmendation and specification for 5 (Five) years under DLP of Phase-I..23.The Contractor shall arrange technical vetting of the plant during execution by the Cyber/INT officer and training by Unit Technical Pers till defect liability stage of Phase-I. 42 24.a) An energy meter (for net-billing) shall be installed between the solar Grid-tied inverter and the building distribution board to measure gross solar AC energy production (the Solar Generation Meter). The Solar Generation Meter shall be of the same accuracy class as the DISCOM service connection meter or as specified by local regulatory requirements. Separate for two different buildings.b) The bidder must take approval/NOC from the Concerned DISCOM for the connectivity, technical feasibility, and synchronization of SPV plant (if required).c) Contractor shall be provided system software (Cloud) for data hosting of Solar Power Plant with the Government approved agency and also audited by CERT-In (Computer Emergency respose team-India) is deemed to be included in the quoted rates. 25.a) Two sets of Engineering, electrical drawings, and Installation and O&M manuals are to be supplied. Bidders shall provide complete technical datasheets for each equipment giving details of the specifications along with make/makes in their bid along with the basic design of the power plant and power evacuation, synchronization, along with protection equipment is deemed to be included in the quoted rates. 43 b) All test and calibration certificates, wherever applicable.26. The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.27. (a) The bidder shall take entire responsibility for the electrical safety of the installation(s) and personnel, including connectivity with the grid and follow all the safety rules & regulations applicable as per local guidelines and regulations, etc. Insurance of the installers (of the vendor) working abroad is mandatory.(b) The contractor will carry out fortnightly, monthly, quarterly and annual maintenance as per Proforma of Appendix here-in-after respectively. In case the contractor fails to carry out the above maintenance following penalty per Solar will be imposed. 44 (i) Not carrying out maintenance fortnightly- Rs 2500.00(ii) Not carrying out maintenance Monthly- Rs 5000.00(iii) Not carrying out maintenance quarterly- Rs 7000.00(iv) Not carrying out maintenance annually - Rs 10000.00(c) The Contractor shall be responsible for ensuring production of 800 kW AC output of electricity at the injection point of RMU atleast once in a year from the SPV plant. In case the output is less than 800 kW AC unit, it will be deemed as under-designed plant. The contractor will be responsible for making good the shortfall by repair / replacement of the SPV Plant free of cost. Delay in this regard will attract monetary penalty to be amounted for the period wef very next day of the completion of Phase-I to the date of completion of rectification / replacement by multiplying the maximum value of units less generated than 800 kW AC for every day with the prevailing rate of electricity tariff of WBSEDCL Rate of electricity in West Bengal is Rs 6.52 per unit as in Sep 2025.(d) Maintenance and supervision shall be done by trained men for the safe operation of Solar’s contractor shall carry out fortnightly servicing including adjustment lubrication, repair of replacement fo parts if necessary. In addition to fortnightly servicing contractor’s senior mechanic of foreman shall carryout the inspection as per maintenance schedule and make necessary entries in the proforma attached here-in-after duly signed by Contractor & Engg-in-Charge as applicable kept in the switch room for this purpose. It will be the responsibility of the contractor to see that the maintenance schedule book is maintained properly by their senior mechanic or foreman. They shall promptly attend and call back & shall not be kept pending for more than 4 hours unless it has the prior approval of the Garrison Engineer. 45 (e) For any repairs/ replacement of Solar the contractor shall always be aware of time factor following are the fixed time (including Sunday/Holiday) for repair/replacement of parts/components/ accessories which shall be adhered to :- (i) Minor repair/ replacement- 4 hours (ii) Major repair/ replacement - 1day(f) The decision of the GE regarding Minor/Major repair shall be final conclusive and binding. In case of failure on the part of the contractor to keep the solar’s in running condition within the stipulated period mentioned in above the contractor is to pay penalty charges as mentioned below subject maximum of 10% of the total contract value and after that measurement will not be considered for the same defective Solar till it is in satisfactory working condition :-(i)Upto 12 hours @ 2000/-(ii) Above 12 Hours and up to 24 hours @ 5000/-.28. RFID Tag scanner of reputed make shall be provided by the contractor is deemed to be included in the quoted rates.29. Existing Room at 33 KV Switch Yard shall be used for SCADA/ Solar equipment/Control Room. 46 30. Surface preparation and laying of light yellow/white coloured interlocking tiles of appropriate thickness under the whole area of PV module array to make a reflecting surface for bifacial Solar PV module alongwith periodical water sprinkling arrangement for cooling of interlocking tiles is deemed to be included in the quoted rates. 31.The complete system shall include chemical earthing (as per OEM recommendations) and earth strip/cable etc for earth of SPV module, array, inverter,DC & AC boxes /LA etc as per latest IS/MNRE/IREDA/NISE/SECI/ALMM specifications and guidelines is deemed to be included in the quoted rates. Earth resistance shall not be more than 3 Ohms .32. The mounting steel structure shall be as per IS 2061-1992 and galvanizing as per IS 4759 and should withstand WIND Load as per relevant IS Code/NBC.33.Soil Stabliztion testing certificate needs to be required before completion of physical completion of work (Phase-I) so that the performance of the PV Plant is not affected in Highly Soiled areas for minimum 25 years. 47 34. M&O (Phase-II) should be finalize at the planning stage itself. The important point are as under:- (a) The thermal imaging of pv panel should be taken once a year for checking its health including hot spots.(b) The cleaning cycle of panel should be fixed as per the ratio of short circuit current falling below 0.9. The cleaning provision shoul be made available before evacuating the power.(c) The shutdown duration of inverter should be monitored and recorded and analyzed 48 Supplying, Installation, Testing & Commissioning including design, manufacture and testing at works of indoor type , IP 4X ,floor mounted metal clad, 11 KV VCB panel board totally enclosed & fully interlocked, Horizontal drawout, Horizontal isolation type breaker as per IEC-62271-100/200, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, motor charged and manually/electrically closing breaker suitable for use on 11 KV,3 Phase, 50Hz A.C. supply with STC 25 KA for 3 Sec.Internal Arc for AFLR 25kA at rated voltage for 0.1s at individual compartments i.e. Busbar, VCB and cable compartment.complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated and encapsulated copper bus bars of 800 Amps capacity, breaker featured with mechanical ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 8 NO + 8 NC andequipped with following switch gears and accessories.The panel shall be complete with following switchgear and accessories. The structure of the switchgear must be fabricated using steel sheets coatedwith Alu-Zinc (Aluminium Zinc alloy)/PRINTED CRCA All major sub-components (switchgear, relays, meter & vacuum interrupters) shall be of same make. VCB and vacuum interrupters shall be designed for 100 short circuit operations at full short circuit of 25KA. Breaker shall be roll on floor type/ CASSET TYPE. Separate earthing truck shall be required for each bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth a live. It shall be provided with capacitive voltage divider and complete with audio visual annunciation, one for each panel. Item Continued as 2.01 to 2.04 49 INCOMINGS & Outgoing VCBs :Type : Air insulated VCB, autoreclosing, system voltage :- 11kV + 5%, 50 Hz+ 5%, 3 phase, rated voltage : 12kV, rated current : 800A in 40 ° C ambient, Short time rating for 3 sec : 26.3 kA, Short Circuit Making Current : 65 kA, insulation level (PF rms/ impulse peak) : 35 kA/75kA, System Ground : Solidly Earthed,Duty Cycle : 0 - 0.3 sec - CO - 3 min - CO, Break/ Make time :- Not more than 5 Cycle, Range for Auxiliary voltage for Closing / Tripping / Spring Charging : 85-110%/ 70-110%/85-110%. of rated voltage. The VCB must withstand 10000 mechanical, & 100 at rated short circuit current. The breakers should have auxiliary contact 6 No+ 6 NC, in minimum. The used Breakers will comply with IEC 62271/ IS 13118. Qty. - 3 Nos (1 no Incomer & 1 outgoings)Busbar: Rated Current : 800A @ 40°C ambient, Material : Silver Plated /Tined , High conductivity elecrolytic Copper Bus Bar sleeve :Heat Shrinkable PVC Sleeve with joints having full voltage soft PVC shroude Short time rating for 1sec :26.3kA -1 setCurrent Transformer:Voltage class: As specified in Circuit breaker ; Type: cast resin type, Dual core, Dual Ratio , Barden :10VA; Class insulation : Class E or better . Protection core: 5P10, Metering : 1.0 , Short time rating for 1 sec :26.3kA Ratio :300-150/1-1, 7 setsBus Potential Transformer: Rated Voltage : Primary - 11000 / ✓3 , Sec -110✓3; Type : Cast resin , draw out type, 3- phase , 3-limb complete with HV fuses . Barden : 100VA per phase ; Class of insulation : Class F or Better , Accuracy Class: 1.0;Rated Voltage factor : 1.2 continuous, 1.5 for 30 Secs. PT shouldbe drawnout type and serivce continuously shall be indepandent of Breaker trolly position...1set 50 Relay for Control & Protection: Numerical Type IDMT Relay (50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Additionally, condition monitoring CB wear, condition monitoring CT supervision, disturbance recorder, undervoltage & over voltage protection, trip circuit supervisioncan be measured through the relay. The device shall support webserver/web HMI through which we can monitor and control the relays over a ethernet Lan network. Licenses for theprogramming software shall be provided free of cost.The numerical relay shall have large mimic-based LCD screen display . .The relay shall have 8 Digital inputs and 8 Digital Outputs and one additional watchdog ouput.The device has to aloe controlling of min. six objects (circuit breakers, disconnectors and grounding switches). Controlling has to be done by “select-execute” or “direct control” principle. Controlling has to be possible by: through local HMI, remote communication, via digital input or via function key. Events has to be readable to SCADA systems, front panel or by setting software.The sample rate of the recording has to settable to 32samples/cycle.The devices shall provide storage up to events 2000 based on the resolution.The device shall support following communication protocols: Native IEC 61850 ed1 & ed2, Modbus TCP. The IEC 61850 communication has to support peer to peer communication (GOOSE) if requiredThe IEC 61850 interface must be able to configure through setting software. Also the same setting software has to be able to generate ICD filesThe device shall have KEMA IEC61850 edition 2 certificates - 3 sets. High Speed Master Trip relay VAX31- 3 Set, Ttrip circuit supervision relay-VAJH13-3 set6 Window Annunciation Facia . with ACCEPT, RESET & TEST Push Button - 3 set . Auxillary relay for Transmission faults (VAA33)- - 3 Set 51 Metering: Meters: 1-NosUL&CE Multifunction Digital meter displaying Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.Temperature Monitoring Sensor for the Three Phases of Incomer VCB Panel :Supply, installation, testing & commissioning ofthermal monitoring system to be provided to detect abnormal temperatures due to faulty connections and to prevent equipment B19damage. The switchgear shall have wireless temperature measurement sensors at all critical points:(a) 3 nos. foreach phase at incoming side cable joints The wireless temperature sensors installed on conductors shall be :(i) Installed with direct contact to hot point, to achieve accuracy of +/- 2°C(ii) Self-power (no auxiliary supply, no battery)(a) communicate wirelessly(c) Operate from -25°C to 125 °CThe system shall allow 2 configurable thresholds (pre-alarm and alarm). This system shall have integrated algorithms enabling to anticipate as early as possible an abnormal temperature, before damage occur (strong predictive capacity) and generate alarm through SCADA/monitoring software. Thermal sensor shall beself powered by the network current. Temperature data is sent via Zigbee wireless communication to provide high performance and accurate thermal monitoring. The sensor is secured to the connection point and is in direct contact with the measured point. Smartphones or tablets (with a Zigbee communication dongle) can be used with our Thermal Connect mobile application to scan data locally and can replace the need of periodic infrared scanning. Thermal sensors should comply to following standards:1 EN/IEC 61010,2010 2. UL 61010-12, 20123. ETSI EN 300238, 2012 V1.0.1 4. IEEE 802.15.4, 2013 52 Power Pack shall be with 220Volt AC Input & 24 volt DC continuous output suitable for closing /tripping indication of HT panel boards with 2nos 12Volt 100AH maintenance free batteries, chatging unit for trip system complete with suitable capacity dogital MFM connections with 2.5sq mm FRLS inaulated copper conductor cable etc as required.-4 set.The 11 KV HT Switchboard of 1 panel,shall bewith all accessories, interconnections,internal wiring, labels, space heaters etc. complete as required.3 panels shall be mechanically interlocked in such a way that only one operates at a time and multifunctional digital meters shall be interconnected and programmed in such a way that total consumption will come in one meter summating both of them.Note: 1. Quotated rates shall be inclusive of construction of foundation for the installation of VCB as per OEM drawing.2. The equipment shall be tested by SEI post sucessful installtion and report shall be submitted to this office. 53 Design, Manufacturing, Supply, Installation, Testing and Commissioning of 3 way 12 kV rated Ring Main Unit ofwith Fault Level 21KA 3 sec internal ARC 1 sec for tank and cable box , consisiting of 630A12 kV rated , 2 nos motorized type VCB as incomers & 1 load break switch as outgoings with metering modules along with necessary Earth Switches,battery and battery charger for shunt trip arrangement andMotor and other auxiliary circuit operation, HT CopperBus bar with current density not more than 1.6A/sq. mm as per detailed description as follows: RMU Construction: The switchgear and busbar shall all be contained in a stainless steel enclosure filled with SF6 at 0.3 bar (300 hPa) relative pressure to ensure the insulation and breaking functions. Sealed for life, the enclosure shall meet the sealed pressure system criterion in accordance with the IEC 62271-1 standard (§ 3.6.5.4): a volume for which no further gas processing is required during its entire expected life”. In addition, manufacturer shall confirm that maximum leakage rate is lower than 0,1 % / year. It shall provide full insulation, making the switchgear insensitive to the environment (temporary flooding, high humidity...), IP67 degrees of protection in accordance with recommendation IEC 60529 § 14.2.7. No SF6 gas handling required at site. Thus assembled, the active parts of the switchgear shall be maintenance-free and the switchboard shall be low-maintenance. The switchgear operating mechanism shall have an IP2X protection and cable chamber shall be IP55, Over all IP protection shall be IP55 . The tank shall be made of at least 2mm unpainted stainless steel. Item Continued as 3.01 to 3.05 54 VCB is the preferred dielectric medium for MV RMUs. Oil filled switchgear will not be considered. RMU shall be in accordance with IEC 60376.Any accidental overpressure inside the sealed chamber will be limited by the opening of a pressure limiting device in the lower part of the enclosure. Gas will be released to the rear or the bottom of the switchboard away from the operator and internal arc tested for both cable and tank for 21KA 1sec AFLR with test conducted with minimum 3 functions TankNumber of mechanical operations of Circuit breaker 2000 O/C , Number of electrical operations at full loop current for LBS: 100 O/C , Number of electrical operations at full loop current for CB: 2000 O/C,. Manufacturer shall provide type test report to prove compliance with IEC 62271-200 Annex A, Internal arc classification class AFL with 21kA 1s for the enclosure. Make of the RMU, vaccum intrtupter , relay & meter shall be of same OEM. All the test certificate shall be in the name of the OEM only . If there is any name change / acquisition by other OEM happened for the RMU then test cerificates shall contain the new OEM name only.HT System : 3 phase -3 wire , HT Fault level21 kA, Power System earthing - solindly earthed at up stream source, HT Copper Bus with Short Time Curent rating 21 kA for 1 Sec ( 3Sec), Continuous current rating at least 630 A. tank and cable chamberof RMU must be IAC rated for 21 kA for 1 Sec AFLR. Design ambient to be considered as 40 Deg C.HT Circuit Breaker :(i) There shall be 1nos.load break switches as incomings and 2 nos 12 kV rated VCBas outgoing ( total 3 nos.) . The circuit breakers shall be fixed type. All of the switchgear shall be capable of withstanding this current without any damage being caused, in accordance with the recommendations IEC 62271-1 and IEC 62271-200.Loss of service continuity class: LSC2(ii) The Circuit Breaker must be rated for 12 kV ( nominal Voltage), 28 kV/75 kVp ,3 Phase, 50 Hz, Short Circuit Fault Level of 21 kA for 3 sec. 55 (iii) No. Of Close Coils - 01 no. operable at 24 V DC (85% - 110%)/ Spring Assited Closing, No. of Trip Coils - 01 nos. ,operabale at 24 V DC ( 70% - 110%) for shunt trip.(iv) Provision for supervision of the shunt Trip Circuits for the Trip Coils to be provided. (v)Switchgear classification: PM class(vi) Loss of service continuity class: LSC2(vii) Duty Cycle : O – 3min – CO – 3min – CO, Vacuum Circuit breaker shall be of M1, E2, C1 duty and capable for minimum 50 short circuit breaking operation at full short circuit level.(viii) STC rating 21 kA for 3 Sec (for Vacuum Interrupter).(ix)Vacuum Interruptor must be hermetically sealed and must comply IEC 60056 ( along with latest amendments). Vaccum interrupter shall be of same make as RMU(x)Circuit Breaker to be equipped with Suitable tripping arrangement with push button, Mechanical counter to assess the total number of operations of the breaker, Mechanical ON / OFF indicator, Auxiliary switches, Auxiliary Contacts( at least 2 NO + 2 NC of Class 2 category), Emergency trip push button.(xi) The Operating mechanism shall be spring charged motor operated/ spring assisted as per OEM type tested design type with Spring Charge Universal motor operable on 24 V DC / 230 V AC.(xii)Suitable monitoring of Bircuit Breaker status ( ON, OFF, Trip, CB Spring charged if applicable), Trip Circuit Healthy / Unhealthy, DC healthy/unhealthyto be provided using (xiii) Voltage Presence Indicator shall be provided against each HT circuit ( against each VCB) on line side for knowing the presence of line enerzisation status.(xiv)Number of Mechanical operations at full rated current for breaker: 2000 O/C 56 HT CT /PT : Load Break Switch - 11 KV, 630A, 21KA for 3sec Motorized Load break switch; with built in line side manual earth switch. Earthing should be completed within 2 operations only(i.e 1. Main switch - OFF, 2. Earth switch - ON). LBS shall have 3 positions, open or disconnected, closed and earthed, and will be constructed in such a way that interlocking prevents unauthorized operations. For earth switch, manual opening and closing will be driven by a fast-acting /snap action mechanism, independent of operator action. LBS and earth switch shall have a min of 1000 (M1) mechanical operations ,and 5 nos closing operations at rated SC current. LBS should have 100 electrical operations at rated current. LBS & Earth Switch should have separate apertures for operation.i) One set of 03 nos. ( for 3 phases) dual core Cast Resin CTs for Eachincomer VCBcomplying with IEC:60185 & IS 2705 ( along with latest amendments) , Core -1 - 400-200/1 A , 2.5 VA, Cl 0.5 for metering ; Core-2 - 400-200/1 A, 2.5 VA , 5P10 for Protection.ii) 01 no. of 03 phase Dual Core PT forHT bus ( 11 kV)with protection HRC fuseCore 1- 11kV /√3 / 110V/√3, Cl 0.5s, 50VACore 2- 11kV /√3 / 110V/3, Cl 3P, 50VA(iii) Multifunction Meter:2 Nos. 3 phaseDigital Multifunction Meter6400NGwith Voltage, Amps, kWh, kW, P.F., Active, reactive, apparent energy , disturbance direction detection, Individual harmonic up to the 63rd harmonic. at least 256 samples/cyclewith ethernet Port with inbuilt webserver and complying to IEC 61557-12, IEC 62053-22 certified by third party laboratory.for each VCB panel ( 96 mm x 96 mm) , Flush mounted, Class 1 conforming to IEC 62053-22 ( along with latest amendments). 57 Protection Relay: (i) 2 Nos. of Numerical Type Self-powered IDMT Relay(50/51, 50N/5IN) with two elements for overcurrent and earth fault having settings 50% to 200% for overcurrent and 20% to 80% for earth fault in equal steps with time and current settings and high set instantaneous unit. Relay should communicate on Modbus RS-485.(ii) Each VCB must have separate Anti Pumping Relay / Antipumping feature through motorization circuit.Fault Passageindicator: The FPI shall facilitate quick detection of faulty section of line. The fault indication may be on the basis of monitoring fault current flow through the device. The FPI should be self-powered and should have internal lithium battery for external indication and setting of FPI in the absence of current.The FPIs shall include: Fault detection - Phase to phase and Phase to earth faults.One potential- free output contacts for hardwiring to RTUs. On this basis, the SCADA/DMS will be able to monitor phase / earth fault condition.Local fault indications - LCD display on FPI front panel along with LED indication on front panel of RMU enclosure.Multiple reset option : End of time delay (Adjustable from 2 to 16 Hrs)Remote reset (Via potential free input contact of FPI)Manual reset (Reset button on front panel of FPI)Automatic reset on current restoration.The characteristics of the FPIs shall include: Phase fault thresholds configurable from at least 100 to 800 A,Earth fault thresholds configurable from at least 20 to 200 AMultiple number of steps for adjusting phase and earth fault thresholds. Fault current duration range configurable from at least 40 ms to 100 ms in 20 ms steps and further 100 ms to 300 ms in 50 ms steps. Variations with respect to these characteristics may be acceptable as long as they prove applicable and provide the same or better flexibility. 58 EARTHING : The cables shall be earthed by an earthing switch with short-circuit making capacity, in compliance with IEC 62271-102 standard. The earthing switch can only be operated when the switch is open. The switch and earthing switch operating mechanism shall have a mechanical endurance of at least 1000 operations. Integrated line side Earth switches shall be provided in each HT Circuit. ( against each VCB)RMU Bushing & Cable Termination: It is preferable to have all bushings accessible from the front of the RMU. Bushings along the sides or the rear of the RMU are not acceptable.For each cable compartment, the bushing shall be at the same height in order to facilitate a possible reversal of the cables. The bushing should be conveniently located for working with cables specified and allow for the termination of these cables: - 630 A M16 bolted connectors for switch-disconnectors and vacuum circuit breakers functions.The profiles of the cable connection bushings shall be in compliance with IEC-60137 standard. Cable clamps:A cable clamp arrangement must be provided for all network cables terminated on the RMU.Provision for Cable Entry: There shall be suitable provsion for Cable entry from bottom through 3 mm thick CRCA steel thick detachable gland plate along with provision for termination of 2 runs of 3 c X 300 Sq mm 11 kV (E ) , XLPE insulated Aluminium Cables (for HT side) and at LT side runs of cables matching with outgoing MCCB current rating.Note: (i) Quotated rates shall be inclusive of foundation for the installation of VCB as per OEM drawing.(ii) The equipment shall be tested by SEIaftersuccessful installtion and report shall be submitted to this office and cost deemed to inclusive in qoated rates 59 M&L for water proof, 3 core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade including PVC conduits properly fixed on steel poles using GI wire for electrical connection of street light fittings, complete all as specified and directed. 60 Supply and fixing junction box having protection dust proof, acid resistant, shock proof, fire retardent self extinguisher for outside installation with knockout entry for cable of size 10 - 25 sqmm andminimum size 295x195x95 mm with terminals, with and includingbrackets for street light pole mounting andone 6A MCB SP complete all as specified and directed. 61 M&L for Advanceencapsulated compound based Chemical earthing CPRI tesed maintenance free , pipein -pipe technology upgraded(Zinc & Alloy coated). , Zinc & Alloy coated (80 -100) microns with pure zinc (99.9%) & Alloy coating (200-250) microns. Earthing system conforming IS 3034. The outer and inner pipe should be 76.2 mm and 41.9 mm dia respectively of3 mtrs long zinc coated with additional special alloy coating 300 mm on top side for additional protection of the terminal . The annular space between the pipes to be filled up with Compactfill (CF) (Crystalline Conductive) mixture which should bemachine pressed in the pipes not disintegrate or collapse when outer pipe corrodes . The inner pipe should be extended with terminals for connectivity.The job includes digging the pitsin any type of hard densesoilof min size 1000 X 1000 X 3050 mm depth taking out excavated soil, lowering/ placing thethe pipe in pipe earth electrode in pit in center ,filling of pure conductolite back filling compound (BFC Conductolite) having excellent moisture retaining capacity in 300 mm around the electrode(minimum 4 bags of 25 KG per pit per unit) or more qty of backfillcompoundas required to fill around the the elctrode in 300 mmin circumfrance of electrode . Contractor has to fill the remaining portion of pit withlow resistivity soil (agriculture soil) free from stones etcs, to be bring from out side defence landas the soil resistivity ofStn is very high and mixed with min 3 Bags of 50 Kg each of Bantonide clay. The BFC should be eco friendly it should not contain envernmently hazardous material/metal having ROHS certification from NABL accredited lab.The earth pit should be provided with a FRP earth pit cover for protection and safe guard of terminals. The material of earth electrodeshould have good electrical conductivity & anti corrosion property in wide range of soil conditions. The job also include M & L for in PCC(1:3:6) typeC-1 around the FRP cover for support and foundation and colouring the PCC work withdesired colour.completeall as specified and directed. Item Continued as 6.01 62 Note : (i) Design of earth electrode should be of pipein-pipetechnology .(ii) Contractor have to submit literature of earth electrode and get the make approved of GE before procurement.(iii) The earth electrode shall be CPRI tested to withstand short current test for 60kA rms for 1.0 second and 150kA for peak current.(iv) Contarctor has to fill pure back fill compound conductolite all around the earth electrodein 300 mm bore up to full depth of bore.(v) Contractor shall refill the pit with low resistivity soil (agriculature soil ) free fron stone etc and mixed with 06 bags of Bentonite of 25 Kg each to achive the low resistance values. (vi) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection. This Earthing System used for VCB and RMU only. For Solar Power Plant Earthing System is already deemed to be included in quoted rates.(vii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 6 x Bags of bentonidedeemed to be included in the item rate.(viii) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work. 63 SAFETY EQUIPMENTSSupply and fixing Rubber hand gloves suitable for 11 KVas per OEM recommendationcomplete all as specified and directed. 64 S&F for glass framed Shock treatment chart both in Hindi & Englishand connected accessoriescomplete all as specified and directed. 65 S&F for dry powder chemical type 4.5 kg fire extinguiser with clamps and connectedaccessories ISI Marked complete all as specified and directed. 66 S&F for single line diagram, schematic diagrams etc. of A1 size on suitable Aluminium sheet including lamination etc. as required as per OEM recommendationcomplete all as specified and directed. 67 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed. 68 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, manholes, laying of UG cables/pipes etc. not exceeding 10 Sq.m on plan and getting out in soft/loose or any type of soil complete all as specified and directed. 69 Removing excavated material (soils) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 70 Returning filling in, soft/looseor any type of soil including spreading leveling watering and ramming complete all as specified and directed. 71 Excavation in post holes (or similar holes) in soft/loose soil each n.exc 0.50 cum, getting out,returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface all as specified & as directed. 72 M&L for RCC M-20, design mix (using 20mm graded crushed stone aggregate), including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 73 M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plugs, bolts, nuts & screws as specified type 410 SP-31, 9.0 meter longinclusive of two coats of aluminium paint over one primer coat of red oxide zinc chrome primer including preparation of surfaces complete all as specified and directed.NOTE : (a) The poles shall confirm to IS - 2713 & each component pipe shall be ISI Marked & confirm to IS - 1161. (b) Necessary earthwork, PCC etc. shall be measured & paid separately under relevant items of work. 74 S & F LED Street lights nominal power 90 Watt, LED of Make Osram; Bridgelux ; Philips; Nicha; Cree; Samsung, LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 120 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hourswith IK10 and L70 on including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.(ii)At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt.(iv)All LED lights have replacement warranty of 5 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submittwarranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer.(v) The LED lights will replaced bythe contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly.(vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries from LED manufactutre. 75 M&L for Cement concrete (1:4:8) type D2, (Using 40mm graded crushed stone aggregate) as in foundations of poles and stay, filling and mass concrete complete all as specified and directed. 76 M&L for plain cement concrete (1:3:6), type-C2 (40mm graded crushed stone aggregate) as in foundation, filling and mass-concrete, coping etc for pole foundationwith and including necessary formwork complete all as specified and directed. 77 M&L PCC (1:2:4) type B2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete and copingwith and including necessary formwork complete all as specified and directed. 78 Material & labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtrbelow ground level connected to copper strip 20 x 3.15 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation for earth pitin hard dense soil, rocky / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with low resistivity agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonite , (4 bags of 25 Kg each ), construction ofinspection pit ( earth pit chamber) of brick work of size 600 x 600 x 600 mmwith PCC copping of 1 :1.5: 3, 12.5 mm aggregate A1 with MS sheet 2.8 mm plate cover on frame ofangle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipelightgrade and20 mm GI peforated pipefor wateringetc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately Item Continued as 22.01 79 NOTE :-(i) Contractor shall uselow reisistivity fresh agriculture soil , mixed with 4 x Bags of bentoniteclay of 25 Kg each for refillingthe pit to achive the desired resistance.(ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection(iii) Necessary cost of repair to plinth protection as per existing specification and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints,bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonitedeemed to be included in the item rate.(iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.(v) Contractor has to submit test report of earthing after completing the earthing.(vi) Bentonite clay should be Conf to IS 6186: 1986.(vii) The cost ofCopper strip of size 20X3.15 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately.(viii). All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. (ix) Cost of brazing / welding and nut bolts are deemed to be included in the unit rate. (x) Cost includes removal of excavated soil upto a distance of 100 mtrs. 80 Supply and fixing copper strip of size 20 x 3.15mm as earth continuity conductor or main earthing lead fixed on V typeporcelain insulator, 4 BM, heavy duty ( ceramic bus bar supportinsulator off whitecolour ofsuitable for mounting strip of 20 mm wide x 3.15 min thick) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3.15 mm copper strip brazingto each joints and connected with by providingbrassnut boltsand washer including test point all as specified and directed by Engr in Charge. Note : Insulators shall be provided on every 50 cm. (Minimum 2 x insulators to be provided in every 1 x metre of strip and rate of the same deemed to included in quoated rates) 81 M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and directed. 82 Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and as directed. 83 M&L for GI pipe 100 mm bore, light grade with all fittings and fixtures (ISI Marked), laid in trenches, under road or fixing on wall/ pole /crossing drain /nallah etc. of bore complete all as specified and directed. 84 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 85 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 86 Supply, laying, jointing & testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc.with all fixing & connecting accessories complete all as specified and directed. 87 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 63 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 88 Supply, laying & testing PP-R IS-15801 (Polypropylene random co-polymer) pipe 3-layer 32 mm dia (outer green coloured UV stablilized, middle black coloured UV stabilized and innermost layer white coloured with anti-microbial property) fusion welded grade PN-10 SDR-11 ( Pressure nominal 10KGS/cm2 ) having thermal stability for hot & cold water supply including all types of plain and brss threaded PPR fittings of any size such as elbow, tees, FTA and MTA etc laid in trenches complete all as specified and as directed.Note:The contractor shall submit 15 Years warranty certificate against leakageand defect liabilty period deemed to amended acordingly. 89 S&F for 63mm (OD) PP-R Gate valves (brass insert)and connected acessories complete all as specified and as directed. 90 S&F for 32mm (OD) PP-R Gate valves (brass insert) nd connected acessories complete all as specified and as directed. 91 M&L for hard core of gauge not exceeding 63mm with broken stone or boulders, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed. 92 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658-2006 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 93 S&F for RCC pipes of 600 mm dia, NP-2 laid and jointed complete with collars complete all as specified and directed. 94 S&F for 250mm bore Flue pipes of mild steel sheet, black, in suitable lengths as approved by GE and fixed to walls complete all as specified and directed. 95 M&L for Brickwork with fly ash bricks (modular bricks ), straight or curved on plan exc 6m mean radius, built in cement mortar(1:6) complete all as specified and directed. 96 Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be deemed to included in qoated rates. 97 M&L for applying three coats of white wash on newly plastered wall surfaces including preparation of surface complete all as specified and directed. 98 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. Wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 99 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and directed by Engineer-in-charge. 100 S&F flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed. 102 Supply and fixinggalvanized steel chain link fence fabric of mesh size as approved , made out of 4 mm nominal dia of mesh wireconforming to IS 2712-2003 and having zinc coating of type heavy as laid down in IS-4826 including line wires/ binding complete all as specified and as directed(A Board of Officers under the orders of GE shall be convened to ascertain the weight per square metre of galvanized steel wire chain link fencing brought at site by the contractor against each lot of materials). 103 S&F 10mm round bars Fe-410-W (Gde-250) quality-A or Fe-290-(Gde-E-165) as in stiffner to hold the chain link fencing fixed with angle iron post inclucinding necessary welding and fixing arrangement at ends complete all as specified and directed . 104 S&F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steelpins, etc. complete all as specified and directed . 105 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 106 Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surface not exceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. 107 Materials and Labour for reinforced cement concrete M-20design mixin columns; pillars; piers; posts; struts etc,complete all as specified and directed. 108 S&F for Mild steel TMT bars 10mm dia and over, conforming to Fe 500 D, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 109 S & F for mild steel TMT bars 6 to 8 mm dia, conforming to Fe 500 D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, stirup,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 110 M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron) frame of size 50 x 50 x 6mm and locking arrangements including painting one coat of primer followed by two coats of black sysnthetic paint including excvation and earth work in any type of soil,PCC (1:4:8) type D2 in foundation ,PCC benching 1:2;4 type B-1 ,PCC (1:5:8) block masonry 20 cm thick in cement mortor (1:6),10 mm thick plastering in CM 1:4 ,PCC bed in (1:3:6) and coping 50mm hick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork,paintin one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of sizes 800mm x 800mm x800mm (internnal dimensions) complete all as specified and as directed. 111 Sch A Part-II (Phase-II) 112 Providing Services for Manning and Operation of Solar Power Plant 0.8 MWp near 33 KV receiving stationat Sevoke Mil Station for FIRST YEAR after completion of Ph-I of the subject work with oneskilledcategory Electricianhaving certificate of Surya Mitra from NISE) for twoshifts of 8 hour, one helper (semi-skilled category) in two shift of 8 hrs eachcontinuous operation (including Sunday/Holiday) to maintain sub station in/out side Panels, Invertor, DC junction box, VCB as specified, including daily and weekly check up including cleaning of PV modules complete with suitable cleaning cloths etc , upkeeping the installation operational and in health condition, having own conveyance and communication system like mobile etc. complete, for Solar Power Plant with all minor consumable and expendable items and labour and tools for smooth and efficient operation complete all as specified and directed by Engineer-in-Charge. Make of spare parts / equipments of the Solar Power Plant :- Same as installed in the preceding phase of the work.Repair or replacement ofdefective components or spare parts will be carried out free of cost under DLP and comprehensive Maintenance as per OEM recommendation up to DLP period included in BOQ item No. 1.00. The Contractor may submit his claim for every months on pro-rata basis subject to condition 64 of IAFW-2249 (General Conditions of Contracts)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 17,92,949.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. Item Continued as 56.02 to 56.06 113 NOTES :- In addition to and Manning, Operation and Maintenance of Solar Power Plant, the following works will also be carried out by deputing addl manpower where required, to the entire satisfaction of Engr-in-Charge.(a) Minor repairs and preventive maintenance required to ensure serviceability and efficiency of complete MRS complex including supply of HT 11 KV fuse wire of proper sizeand minor spares such as nut, bolts, spring, lock nut of VCB/OCB as per sample, broom, duster, grass cutting tools, phawara, pick axes for cleaning/grass cutting of complete at Sub Stn Complex. 114 (b) Record of activities such as voltage / current / PF / Energy consumed / temp of transformers, break downs, day to day maintenance of Solar PV Plant etc.(c) The contractor shall ensure that all safety precautions are strictly exercised by the staff employed by him.Adherance to IE rules and statutory rules in vogue must be ensured.The contractor shall be fully responsible for any mishap that occurs due to any fault of the employee or due to non adherance of safety norms.(d) Record of activities such as attendance register, duty roster, pay distribution register of the whole staff employed by the contractor.(e) The electrician staff employed by the contractor shall be ITI holder with four years experience. 115 (g) Security lights within the complex will be operate by the tenderer. (h) The under mentioned tool kitwill be provided at site with person on duty :-(i) Electrician tool kit such as screw driver set, tester, test lamp, cutting plier, insulation tape, fuse wire of required size. (ii) Tongue tester(iii) HT megger(iv) First aid box (v) Shock treatment chart duly framed(vi) 33 and 11 KV Hand gloves(vii) 33 KV discharge rod withcopper chain(viii)) Helmet -02 nos(ix) Suitable Footwear - 02 nos(x) Cotton protective clothing with long sleeves duly embossed with GE Sevoke as directed. The tenderersquoted rates shall be deemed to be include the cost of all above provisions and nothing extra will be paid on any account. 116 (xi) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wagespaid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. (xii) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xiii) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. Name of the firm and designation on front and on the back of the T-shirt along with protective clothing, Industrial safety shoes, protective gears like helmet, safety belt etc..(xiv) Supervision and attending of all incoming & outgoing Solar Power Plant equipment metering equipments & monitoring to loads & other parameters of incomming & outgoing feeders & maintaining log sheet and attendance sheet. 117 INSURANCE: The Bidders shall also insure the workmen employed on the job.The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations. 118 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for SECOND YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 18,75,076.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 119 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for THIRD YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 19,61,175.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 120 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FOURTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 20,51,671.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 121 All as perBOQ serial item No 56.01 to 56.06 as mentioned here-in-before but for FIFTHYEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 21,46,848.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 122 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for SIXTH YEAR after completion of Ph-I of the subject work .NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 22,46,564.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 123 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Seventh YEAR after completion of Ph-I.NOTE :- (a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 23,51,386.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 124 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but forEight YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 24,61,315.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 125 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for Ninth YEAR after completion of Ph-I.NOTE :-(a)The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 25,76,917.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 126 All as per BOQ serial item No 56.01 to 56.06 as mentioned here in before but for TENTH YEAR after completion of Ph-I.NOTE :-(a) The bidders shall ensure that the quoted amount for O&M is not less than minimum fair wages i.e. quoted amount is not less than the prepriced amount i.e. Rs 27,03,441.00. If quoted amount is less than the prepriced amount, same will be amended to pre-priced amount.Amount so adjusted will be deducted from quoted amount against Sch A Part-I i.e. Item No. 1.00 of BOQ. Quoted Amount of tender as a whole will remain unchanged due to this adjustment. 127 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIRST YEAR after expiry of DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum andcost of item priced upto ₹500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost. Repairs of minor components any other major components are also in the scope and cost of labour for minor / major components is deemed to be included in the quoted rate for this item.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 128 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor SECOND YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted costrepairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 129 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor THIRD YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 130 Comprehenisve maintenance ofSolar Power Plant 0.8 MWpfor FORTH YEAR after DLP of Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d)Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 131 Comprehenisve maintenance of Solar Power Plant 0.8 MWpfor FIFTH YEAR after DLPof Ph-I of the subject work with including periodical Check up andmaintenance as per OEM recommendation& connected accessories through Authorised Original Equipment Manufacturers Service Centre Engineersor through OEM Certified Agencies as approved by GE, complete all as specified and as directed. NOTE :-(a) Service engineer will carry scheduled preventative maintenance checks on SPV as per the standard check list of the OEM. (b) Service engineer shall carry out checks on Solar Plant, as per the manufacturer’s check list and as directed by Engr-in Charge and would correct / recommend / suggest improvement in operation and performance. (c) Service Engineer during the visit will report on the performance or any other abnormality and inform parts requirement, shall also submit the report on work done and recommendations as well as spare parts offers to the concerned authority for arrangement.(d) Cost of equipment and spare parts which is not covered in warranty and DLP shall be measured in PC Sum and cost up to Rs. 500.00 shall be deemed to be included in the comprehenisve maintenance quoted cost repairs of minor components any other major components are also in the scope of Annual Maintenance Contract.(e) Cost of gaskets, metal/rubber washer, CI washer special cement and small nuts/bolts and screws required for repair shall be deemed to be included in the unit rated quoted by the contractor. 132 Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents.(a) Provide a prime cost of Rs.3,00,000.00 forsupply only of spare parts required for comprehensive maintenance after expiry of DLP of Phase-I, through a BOO convened by the CWE. The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE.(b) Bidders/Contractors quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidders/Contractors is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidders/Contractors quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum. Item Continued as 70.01 133 NOTE:-Prime Cost Sum shall be governed in terms of condition 1 (v) and 5 of IAFW-2249 (General Condition of Contract) and to be regularized through Deviation Order. The following procedure shall be adopted to execute the Prime Cost Sum :-(a) Step –I Service Engineer of OEM along with site executive shall visit every month for Preventive and corrective maintenance on all the Solar Power Plant as specified in BOQ herein before, and undertake routine comprehensive maintenance and identify the list of damage / defective spare parts in Solar Power Plant. Service Engineer have to submit report to concerned Engr-in Charge and BOO before undertaking replacement/ repairs, except in case of emergency.(b) Step –II Subsequently BOO will verify the same and submit the finding to the CWE after assembly of board in terms of CA Provision for concurrence.(c) Step –III After concurrence of BOO, the Engr-in-Charge will direct the contractor and the service provider to replace the unserviceable spare parts.(d) Step –IV Serviceability certificate of Solar Power Plant duly signed by the Service Engineer, BOO findings, GST enabled purchase voucher for the replaced spare parts alongwith draft DO details shall be submitted to the GE for placing of DO’s. The advance on account shall be accompanied alongwith the said DO’s for payment.
Contract Date: Mar 17, 2026 Contract Value : 6.86 Crore
Statutory Bodies & Commissions/Committees No of Bidders 6
West Bengal View Result →
33.
Petroleum and Natural Gas #9544088 Technical Bid
Tender For Composite Works For Ambient Air Heating System Project At Kll Dabhol; 1 PIPING-OFFSITES 2 PIPING (ABOVE GROUND) :-Transportation of all piping items from Owners storage point to work site/work shop; fabrication including cutting, edge preparation, (inclusive of grinding the edges of pipe, pipe spools, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required); fitup, bending, preheating wherever required, welding, threading, and laying of pipes and pipe spools (spools along with supports) of all types and thickness over sleepers, overhead on racks and at all elevations, hook-ups with existing piping, connecting with equipment nozzles, strainers, steam traps, static mixers, sight flow indicators, thermal sleeve, orifice assemblies, spray nozzles, rotameters, tappings for pressure gauges, thermowells, sample connections, sample coolers, closed sample system cabinets etc. and fixing of gaskets, bolts, nuts including application of torque wherever requiredandall other inline instruments and fittings, like elbows, reducers, tees, flanges, spectacle blinds and spacer and blinds, piping specials such as mitres and fabricated fittings, vents, drains (but excluding reinforcingpads), SW valves upto 1.5 NB, Steam Supply/ Condensate Recovery stations(Cast/Fabricated), Supplyandwelding of Strip as per EIL Std 7-51-0112 to all pipes before hydro-testing at exit points of Units for earthing purpose; alignment, cleaningandflushing by water/compressed air,hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified draining, drying by compressed air, performing Positive Material Identification(PMI) using alloy analysers, completing all such works in all respects (including preparation of isometrics as mentioned in the Scope of Work for the job) as per the specifications, drawings and instructions of Engineer-in-Charge. PMI shall be performed by third party as defined in PMI spec.Rates for tubing (if any) shall include rates for valves, fittings, all in line instruments and testing etc. Carbon steel piping includes LTCS piping also. Erectionof all inline instruments like flow instrumentsandspecialty items like static mixers, sample coolers, thermal sleeve, air mixers, exhaust head, rupture disk, flow meters, venturi tube, flame arrestor, thermal flow switch etc. except valve shall be considered as part of piping and separate payment shall not be made on this account. Note : Contractor to refer to Instrumentation SOR for specific details and rates of Instrumentation items not covered herein. 3 CARBON STEEL PIPING (NON IBR); THK. <= 10MM 4 FABRICATION (BUTT WELD- MANUAL) 5 NB UPTO 1.5 INCH 6 NB 2 INCH - 6 INCH 7 NB 8 INCH - 14 INCH 8 NB 16 INCH - 24 INCH 9 NB 26 INCH - 36 INCH 10 FABRICATION (FILLET WELD) 11 NB UPTO 1.5 INCH 12 ERECTION (OTHER THAN SPOOL) 13 NB UPTO 1.5 INCH 14 NB 2 INCH - 6 INCH 15 NB 8 INCH - 14 INCH 16 NB 16 INCH - 24 INCH 17 NB 26 INCH - 36 INCH 18 CARBON STEEL PIPING (NON IBR); THK. > 10MM AND <= 20MM 19 FABRICATION (BUTT WELD- MANUAL) 20 NB 8 INCH - 14 INCH 21 NB 16 INCH - 24 INCH 22 NB 38 INCH - 48 INCH 23 ERECTION (OTHER THAN SPOOL) 24 NB 8 INCH - 14 INCH 25 NB 16 INCH - 24 INCH 26 NB 38 INCH - 48 INCH 27 STAINLESS STEEL PIPING (NON-IBR); THK. <= 10MM 28 FABRICATION (BUTT WELD- MANUAL) 29 NB UPTO 1.5 INCH 30 NB 2 INCH - 6 INCH 31 FABRICATION (FILLET WELD) 32 NB UPTO 1.5 INCH 33 ERECTION (OTHER THAN SPOOL) 34 NB UPTO 1.5 INCH 35 NB 2 INCH - 6 INCH 36 VALVES :- Transportation of all types of valves (Including special valves and motor operatedvalves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Note : For PRDS, PSVs, TSVs, Control valves, On-Off/Shutdown valvesandSelf actuating valves all details and rates shall be as per Instrumentation SOR. 37 FLANGED/WAFER VALVES INCLUDING MOV (UPTO 600#) 38 NB2.000 INCHES 39 NB3.000 INCHES 40 NB4.000 INCHES 41 NB6.000 INCHES 42 NB8.000 INCHES 43 NB 10.000 INCHES 44 NB 12.000 INCHES 45 NB 20.000 INCHES 46 NB 24.000 INCHES 47 NB 42.000 INCHES 48 SPRING SUPPORT ASSEMBLIES :- Transportation of all types of spring support assemblies from Owners storage points to contractors stores/worksite and installation of spring support assemblies for all rating including assembly, if any, fixing of gaskets bolts/nuts, welding attachments wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. Contractor to ensure that travel stops are removed and spring is locked in cold load position for Hydrotest. It shall be ensured that locking devices are removed and springs are properly set at hot load position during commissioning. 49 SOR Sl. No.: 49 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M21901000000 50 BOLT TENSIONING :- Carrying out tensioning of bolted joints on all types of piping as called for in EIL Specification No.6-76-0002 on already erected system including supply of all materials, recording devices, instruments etc; Providing all normal and special equipment and gadgets, skilled / un skilled labour, specialist, supervisory staff and completing the work in all respects as per specifications and instructions of engineer-in-charge. some joints may require bolt tensioning more than once, but, payment for one joint shall be made only once. 51 150# JOINTS 52 NB 12.000 INCHES 53 NB 16.000 INCHES 54 NB 18.000 INCHES 55 NB 20.000 INCHES 56 NB 24.000 INCHES 57 NB 42.000 INCHES 58 300# JOINTS 59 NB 12.000 INCHES 60 NB 24.000 INCHES 61 REINFORCING PADS FOR PIPES :- Fabrication ofreinforcingpads for pipeconnection wherever required (from pipes only suppliedbytheOwner) and erection, fitup, weldingandtesting (including DP/MP) if required of the same and performing Positive Material Identification(PMI) using alloy analysers as per the specifications, drawings and instructions ofthe Engineer-in-Charge. Note: Sizes mentioned forReinforcing Pads are for branch pipe 62 C.S REINFORCING PADS 63 NB2.000 INCHES 64 NB3.000 INCHES 65 NB6.000INCHES 66 NB8.000 INCHES 67 NB 10.000INCHES 68 NB 12.000 INCHES 69 NB 18.000INCHES 70 NB 24.000 INCHES 71 NB 28.000 INCHES 72 RADIOGRAPHY :- Performance of radiographic inspection on piping of all typesandthicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferencial weld joints. 73 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 74 NB0.750 INCHES 75 NB1.000 INCHES 76 NB1.500 INCHES 77 NB2.000 INCHES 78 NB3.000 INCHES 79 NB4.000 INCHES 80 NB6.000 INCHES 81 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 82 NB2.000 INCHES 83 FOR JOINTS ABOVE THK. 8MM 84 NB8.000 INCHES 85 NB 12.000 INCHES 86 NB 18.000 INCHES 87 NB 24.000 INCHES 88 NB 42.000 INCHES 89 DYE PENETRATION/MAGNETIC PARTICLE TEST :- Performance of magnetic particle/ dye penetrant test including supply of all necessary materials, equipment and labour for carrying out the work as per specification and directions of Engineer-in-Charge. 90 DYE PENETRANT TEST 91 MAGNETIC PARTICLE TEST 92 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY OWNER) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour,returning surplus materials and scrap etc to owners storage points and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 93 DUMMY PIPE SUPPORTS FOR C.S (OWNER SUPPLIED) 94 DUMMY PIPE SUPPORTS FOR S.S (OWNER SUPPLIED) 95 PIPE SUPPORTS (FROM MATERIALS SUPPLIED BY CONTRACTOR) :- Fabrication, erection(at all elevations) of pipe supports like shoes, cradles,hangers, clamps(of all sizes/thicknesses manufactured by forming method using die), turn buckles, saddles, guides,special supports, pads(including corrosion pads & protection shields), providing and welding of stiffeners as per drawings, T post etc. of all types including supply and application one coat of primer, all necessary equipments, consumables, labour, and completing work as per drawings, specifications and instructions of Engineer-in-charge. Modifications/rectifications, if required; andadjustment/ alignment during precommisioning, commisioning as per the instructions ofEngineer-in-charge. Fabrication of extension of spindle for valves, provision of locking arrangement, etc. shall also be considered under this item. 96 C.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 97 S.S STRUCTURAL STEEL (CONTRACTOR SUPPLIED) 98 DUMMY PIPE SUPPORTS FOR C.S (CONTRACTOR SUPPLIED) 99 DUMMY PIPE SUPPORTS FOR S.S (CONTRACTOR SUPPLIED) 100 WOODEN/HIGH DENSITY PUF SUPPORTS FOR COLD LINES :- Supply, shaping, positioning and fixing of cold line supports as per EIL pipe support standard having the following specifications: Wood specification:Hard wood, chemically treated with creosote under pressure. Quality of wood to conform class-I durability as per IS-3629 & Grade-I timber of Group-A withpermissible compression strength of 70 Kg/cm2 perpendicular to grains as per IS-883. PUF specifications: Density for lines upto 6 NB : 240 kg/cm3 Density for lines above 6 NB : 320 kg/cm3 101 WOODEN BLOCKS 102 HIGH DENSITY (240 Kg/Cu.M) PUF BLOCKS 103 HIGH DENSITY (320 Kg/Cu.M) PUF BLOCKS 104 CHEMICAL CLEANING/PICKLING :- Cleaning and pickling of equipment/pipeline includng preparation of circulation loop, supply of temporary piping, pumps, heater coils, gaskets, thermometer, hydrometer, valve, test coupon, spares, laboratoryfacilities, with all accessories for conducting test, chemicals, safety accessories and also providing or hiring all necessary equipment and whatever else even though not expressly mentionedhereinandinspecificaions but required to perform the work as per specifications and instructions ofEngineer-in-Charge. 105 PASSIVATION OF COOLING WATER LINES 106 NB0.500 INCHES 107 NB0.750 INCHES 108 NB1.000 INCHES 109 NB1.500 INCHES 110 NB2.000 INCHES 111 NB3.000 INCHES 112 NB4.000 INCHES 113 NB6.000 INCHES 114 NB8.000 INCHES 115 NB 10.000 INCHES 116 NB 12.000 INCHES 117 NB 14.000 INCHES 118 NB 16.000 INCHES 119 NB 18.000 INCHES 120 NB 20.000 INCHES 121 NB 24.000 INCHES 122 NB 42.000 INCHES 123 FABRICATION & ERECTION OF BLINDS/SPECTACLE BLINDS/SPACER & BLINDS ETC. :- Transportation from owners storage point to work site, fabrication and erection of blinds, spectacle blinds, spacers & blinds of all ratings from plate material of all thicknesses supplied by owner as free issue; cutting, edge preparation, rolling, fit up, welding, cleaning, testing (hydrotesting, MP/DP, radiography), wherever required bolts nuts & gaskets including supply of necessary equipment, consumables, labour etc as per standards / specifications and directions of Engineer-in-charge 124 BLINDS 125 NB0.750 INCHES 126 NB1.000 INCHES 127 NB1.500 INCHES 128 NB2.000 INCHES 129 NB3.000 INCHES 130 NB4.000 INCHES 131 NB6.000 INCHES 132 NB8.000 INCHES 133 NB 12.000 INCHES 134 NB 24.000 INCHES 135 NB 42.000 INCHES 136 SPECTACLE BLINDS 137 NB2.000 INCHES 138 NB3.000 INCHES 139 SPACERS & BLINDS 140 NB 24.000 INCHES 141 NB 42.000 INCHES 142 SUPPLY OF STUDS ALONG WITH NUTS: Supply as per Technical Notes for Fasteners (6-44-0057) from Vendor enlisted in Project Master Supplier List of Studs along with two nutsfor diameter < 1 and 3 nuts for diamemter >= 1of nuts, as per the direction of Engineer in-charge. All Alloy steel fasteners used in SS Piping shall be Hot Dip Galvanized. 143 AS FASTENERS(ASTM A193 GR.B7/B7M/A194 GR.2H/2HM) 144 MODIFICATION/EXTRA WORKS (IF ANY) :- Cutting, bevelling, fitup, welding of different sizes of CS/AS/SS/Higher Alloy piping of all types and thicknessess in shop, in position, on ground/overhead on rack and at all elevations; transportation of pipes, fittings, flanges etc from owners storage point to work site/ work shop, making necessary scaffoldings, consumables, machinery, tools, tackles, labour and supervision including attending repairs for completing the work as per the instruction of Engineer-in-charge. 145 FLAME CUTTING C.S PIPINGIBR/NON IBR 146 HACKSAW CUTTING C.S PIPINGIBR/NON IBR 147 BEVELLINGC.S PIPINGIBR/NON IBR 148 FITUP & WELDINGC.S PIPINGIBR/NON IBR 149 FLAME CUTTINGS.S PIPINGIBR/NON IBR 150 HACKSAW CUTTINGS.S PIPINGIBR/NON IBR 151 BEVELLINGS.S PIPINGIBR/NON IBR 152 FITUP & WELDINGS.S PIPINGIBR/NON IBR 153 REMOVAL ERECTED PIPING(ABOVE GROUND) :- Removal of piping existing/ erected including SW valves for modification as required as per Drawings/P and IDs/instructions of Engineer-in-charge at all elevations, including providing assistance to owner for draining, cleaning and purging of the lines to be removed , unbolting of flanged joints /cutting of pipe lines wherever required, installation of flanges and blind flanges, removal of insulation from insulated lines, removing supports, steam tracers, all fittings and flanges, instruments etc, cutting of pipes in appropriate length for transporting purposes, cleaning, flushing, drying and transporting all materials to storage point(within the complex battery limits) designated by Owner/EIL including stacking of material and disposing of waste etc as instructed by Engineer-in-charge. 154 C.S/A.S PIPING 155 S.S PIPING 156 REMOVAL OF ERECTED VALVES (ABOVE GROUND) :- Removal of all types and ratings of valves by unbolting, cutting etc. as required, cleaning by flushing with water/air etc. asrequiredand transportation of the same to Owners storage point (within thecomplex battery limits) and stacking as per instructions of Engineer-in-Charge. 157 VALVES OTHER THAN CONTROL VALVES 158 NB0.500 INCHES 159 NB0.750 INCHES 160 NB1.000 INCHES 161 NB1.500 INCHES 162 NB2.000 INCHES 163 NB3.000 INCHES 164 NB4.000 INCHES 165 NB6.000 INCHES 166 NB8.000 INCHES 167 NB 10.000 INCHES 168 NB 12.000 INCHES 169 NB 24.000 INCHES 170 NB 42.000 INCHES 171 LOW FRICTION PADS: Supply, fabrication and fixing of low friction pads with suitable bonding materials / fasteners, as specified in Drawings / Isometrics / Special support sketches. 172 TEFLON PAD WITH COMPRESSIVE STRENGTH (0.25 OFFSET) :1870 PSI 173 GRAPHITE PAD WITH COMPRESSIVE STRENGTH : 2877 PSI 174 PRE-COMMISSIONING / COMMISSIONING ASSISTANCE : Carrying out Pre-commissioning / Commissioning activities such as dropping the valves, control valves and spool pieces, air and water flushing and air-blasting, steam blowing, air drying, re-installing the valves, control valves and spool pieces, leak testing etc. as per pre-commissioning / commissioning specification/ procedure and instruction of Engineer-in-charge including supply of necessary hand tools, equipments/ machinery, consumables (electrodes, filler wire, gas, card board, target plate, scaffolding etc. wherever required) and with single point responsibility of Contractors supervision.Note : This manpower will be utilized forPre-commissioning & Commissioning requirement over and above that already described elsewhere in this SOR.One Man day is 12 hour duty. 175 SKILLED (WITH HAND TOOLS, EQUIPMENT/MACHINERY, CONSUMABLES) 176 SEMI SKILLED (WITH HAND TOOLS) 177 HELPER/ UNSKILLED 178 PIPE DAVITS :Supply, fabrication & erection of pipe davits as per EIL std. 7-12-023 for lowering of aircooler motors/safety valves from structural platforms, fixing the same to platforms, inspection as per specs., supply of all necessary materials, equipment, consumables, labour,supervision etc. The work shall be carried out as per the specifications, drawings & instruction of engineerincharge. 179 SOR Sl. No.: 179 || PART NO: 0 || SOR NO: B861-000-16-43-PK-SOR-3001-0-0M ||ITEM NO: M25201000000 180 SUPPLY OF BULK PIPING ITEMS :- Procurement andsupply of following bulk piping items to site/ownersstorage, transportation to work site/fabrication shop.Procurement shall be done as per EIL specifications andfrom Client/EIL approved suppliers.Contractor shall establish quantities from drawingsconsidering wastage, cutting allowance, escalation &spares required by Client 181 PIPES 182 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.5 INCH, S160 183 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 0.75 INCH, S160 184 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.0 INCH, XS 185 PIPE, B-36.10, ASTM A 106 GR.B, PE, SEAMLESS, 1.5 INCH, XS 186 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.5 INCH, 80S 187 PIPE, B-36.19, ASTM A 312 TP304, PE, SEAMLESS, 0.75 INCH, 80S 188 PIPE, B-36.19, ASTM A 312 TP304L, PE, SEAMLESS, 0.75 INCH, 80S 189 FLANGES 190 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH, XS 191 FLNG.SW, B-16.5, ASTM A 105, 300, RF/125AARH, 1.5 INCH, XS 192 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH, S160 193 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH, XS 194 FLNG.WN, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH, XS 195 FLNG.WN, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH, 80S 196 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 0.75 INCH 197 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.0 INCH 198 FLNG.BLIND, B-16.5, ASTM A 105, 150, RF/125AARH, 1.5 INCH 199 FLNG.BLIND, B-16.5, ASTM A 105, 300, RF/125AARH, 1.0 INCH 200 FLNG.BLIND, B-16.5, ASTM A 182 GR.F304, 150, RF/125AARH, 0.75 INCH 201 FITTINGS 202 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 203 ELBOW.90, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 204 ELBOW.90, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 205 ELBOW.90, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 206 T.EQUAL, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 207 T.EQUAL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 208 T.RED, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH, 0.75 INCH 209 SWAGE.CONC, BS-3799, ASTM A 105, PBE, 0.75 INCH, S160, 0.5 INCH, S160 210 CPLNG.FULL, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 211 CPLNG.FULL, B-16.11, ASTM A 182 GR.F304L, SW, 3000, 0.75 INCH 212 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.0 INCH 213 CPLNG.HALF, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 214 CPLNG.HALF, B-16.11, ASTM A 105, SW, 6000, 0.75 INCH 215 CPLNG.HALF, B-16.11, ASTM A 182 GR.F304, SW, 3000, 0.75 INCH 216 CPLNG.LH, B-16.11, ASTM A 105, SW, 3000, 1.5 INCH 217 VALVES 218 VLV.GATE, SHEET 51001, 0.5 INCH 219 VLV.GATE, SHEET 51001, 0.75 INCH 220 VLV.GATE, SHEET 51001, 1.0 INCH, LOCK OPEN 221 VLV.GATE, SHEET 51001, 1.0 INCH 222 VLV.GATE, SHEET 51001, 1.5 INCH, LOCK OPEN 223 VLV.GATE, SHEET 51001, 1.5 INCH 224 VLV.GATE, SHEET 51007, 0.75 INCH 225 VLV.GATE, SHEET 51045, 0.5 INCH 226 VLV.GATE, SHEET 51045, 0.75 INCH 227 VLV.GLOBE, SHEET 52001, 1.0 INCH 228 VLV.GLOBE, SHEET 52007, 1.0 INCH 229 VLV.CHECK, SHEET 53001, 1.0 INCH 230 VLV.CHECK, SHEET 53007, 1.0 INCH 231 VLV.CHECK, SHEET 53050, 0.75 INCH 232 GASKETS 233 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 0.75 INCH 234 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.0 INCH 235 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 150, 1.5 INCH 236 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.0 INCH 237 GASKET, B-16.20-ANSI B16.5, SP.WND SS316+GRAFIL+ I RING, SPIRAL, 300, 1.5 INCH 238 FASTENERS 239 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.5 INCH 240 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.5 INCH X 2.75 INCH 241 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.0 INCH 242 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.25 INCH 243 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.5 INCH 244 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 3.75 INCH 245 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.625 INCH X 4.0 INCH 246 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 3.5 INCH 247 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.0 INCH 248 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7, A194 GR.2H, 0.75 INCH X 4.25 INCH 249 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.5 INCH X 2.5 INCH 250 BOLT.STUD WITH 2 NUTS, B-18.2, A193 GR.B7(HDG), A194 GR.2H(HDG), 0.625 INCH X 3.25 INCH 251 CLOSE PROXIMITY RADIOGRAPHY:-Performance of radiographic inspection on piping of all types & thicknesses includingproviding or hiring of all necessary equipment and whatever else even though notexpressly mentioned but required to perform the work as per specification andinstructions of Engineer-in-Charge by using SELENIUM& IRIDIUM source basedradiography system. Radiography shall be submitted tothe Engineer-in-charge.(Repeat Radiography due todefective radiograph on reparired joints due toContractors fault and for additional radiographynecessitated due to poor performance of contractorswelders shall be done at contractors cost).Note: Unit for radiography quantity is Nos ofcircumferencial weld joints, and rates are also inclusive of scaffoldings wherverrequired. 252 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF JOB NDE SPECIFICATION) 253 NB0.750 INCHES 254 NB1.000 INCHES 255 NB1.500 INCHES 256 NB2.000 INCHES 257 NB3.000 INCHES 258 NB4.000 INCHES 259 NB6.000 INCHES 260 FOR JOINTS THK. <= 8MM (FOR CS AS PER CLASS lV OF JOB NDE SPECIFICATION/AS/SS) 261 NB2.000 INCHES 262 FOR JOINTS ABOVE THK. 8MM 263 NB8.000 INCHES 264 NB 12.000 INCHES 265 NB 18.000 INCHES 266 NB 24.000 INCHES 267 Supply,fabrication and fixing of low friction pad (SS 304 mirror finish) with suitablebonding material/ fasteners as specified in drawing/documents/special supportsketches/isometrics/Gads etc. 268 STAINLESS STEEL 6 MM THK WITH MIRROR FINISH SS304 269 External Chemical Cleaning and Passivation of SSWelds:External chemical cleaning and pickling of SS welds as per latest approved pipingdrawings and as per Job Specification B861-000-06-42-CCS-011. Work shall includesupply of all chemicals, temporary facilities with all accessories for conducting test,safety accessories and also providing or hiring all necessary equipment and whateverelse even though not expressly mentioned herein and in specifications but required toperform the work as per specifications and instructions of Engineer-in-Charge.(Unit ofmeasurement- No. of Joints) 270 NB0.500 INCHES 271 NB0.750 INCHES 272 NB1.000 INCHES 273 NB1.500 INCHES 274 NB2.000 INCHES 275 PAINTING (OFFSITES) :- Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge for all types of uninsulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. For insulated piping wherever blast cleaning with no primer application is specified, in such cases finish paints shall also be applied inthe fabrication yard.The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabricationas well as erection joints) shall be left unpainted till hydrotesting. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 276 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FORENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 277 DESIGN TEMP GROUP: -16 TO 80(DEG C)SURFACE PREPARATION:SSPC-SP-10;1coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat, FINISH COAT: 2 coats of F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat (2x100 + 40= 240). Total DFT = 345-355. 278 PIPES 279 NB: .5Inches 280 NB: .75 Inches 281 NB: 1 Inches 282 NB: 1.5 Inches 283 NB: 2 Inches 284 NB: 3 Inches 285 NB: 4 Inches 286 NB: 6 Inches 287 NB: 8 Inches 288 NB: 12Inches 289 VALVES 290 NB: .5Inches 291 NB: .75 Inches 292 NB: 1 Inches 293 NB: 1.5 Inches 294 NB: 2 Inches 295 NB: 3 Inches 296 NB: 4 Inches 297 NB: 6 Inches 298 NB: 8 Inches 299 NB: 12Inches 300 SURFACE PREP, PRIMER &FINISH COAT FOR CS & LTCS INSULATED SURFACES FOR ALLENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 301 DESIGN TEMP GROUP: -45 TO 125(DEG C)SURFACE PREPARATION: SSPC-SP-10;1 coat of F-15 @ 75µ DFT/coat, PRIMER: None, FINISH COAT: 2 coats of F-15 @ 75µ DFT/coat. Total DFT = 225 302 PIPES 303 NB: .5Inches 304 NB: .75 Inches 305 NB: 1 Inches 306 NB: 1.5 Inches 307 NB: 2 Inches 308 NB: 3 Inches 309 NB: 4 Inches 310 NB: 6 Inches 311 NB: 8 Inches 312 NB: 12Inches 313 NB: 18Inches 314 NB: 24Inches 315 NB: 28Inches 316 NB: 36Inches 317 NB: 42Inches 318 VALVES 319 NB: .5Inches 320 NB: .75 Inches 321 NB: 1 Inches 322 NB: 1.5 Inches 323 NB: 2 Inches 324 NB: 3 Inches 325 NB: 4 Inches 326 NB: 6 Inches 327 NB: 8 Inches 328 NB: 12Inches 329 NB: 18Inches 330 NB: 24Inches 331 NB: 42Inches 332 SURFACE PREP, PRIMER & FINISH COAT FOR CS, AS & LTCS BARE SURFACES FOR ENVIRONMENT AS PER JOB SPEC B861-000-06-42-PLS-01 333 DESIGN TEMP GROUP: -45 TO -15(DEG C)SURFACE PREPARATION:SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/ coat. Total DFT = 65-75. 334 PIPES 335 NB0.50 INCHES 336 NB0.750 INCHES 337 NB1.000 INCHES 338 NB1.500 INCHES 339 NB2.000 INCHES 340 NB3.000 INCHES 341 NB4.000 INCHES 342 NB6.000 INCHES 343 NB12.000 INCHES 344 VALVES 345 NB0.50 INCHES 346 NB0.750 INCHES 347 NB1.000 INCHES 348 NB1.500 INCHES 349 NB2.000 INCHES 350 NB3.000 INCHES 351 NB4.000 INCHES 352 NB6.000 INCHES 353 NB12.000 INCHES 354 *************************************************************** LEGENDS / NOTES FOR INSULATION WORKS***************************************************************** Types of Insulation :CC =Cold Conservation Insulation SC =Surface Condensation InsulationH = Heat Conservation InsulationCPP =Cold Personal protectionHPP = Hot Personnel Protection Insulation** Basic Line Surface Materials:CS = Carbon Steel (Including LT Carbon Steel)AS = Alloy SteelSS = Stainless Steel ** Notes : 1. For Insulation specification, refer Job specification for Insulation of Piping and Equipment, B861-000-06-43-IL-S001*************************************************************** 355 COLD INSULATION (OFFSITES) Providing thermal insulation including supply of all insulating andancillary materials, Aluminium foil for SS surfaces, vapour barrier, weather protective coverings, consumables and other necessary materials , testing of materials as required , including transportation of materials to work site, duly inspected by 3rd party inspector(Llyods/BV/DNV or any other Client approved party) at manufacturers shop & sample check/inspection at site by EIL Construction inspector,applying insulation on surfaces as specified including all preparatory works there on, binding, tying, lacing, stitching and/or otherwise securing , finishing with cladding as per spec., providing bolts, rivets, and self tapping screws wherever specified , providing inspection windows, end seals for flanges etc., colour coding and identification. Providing steel scaffolding, all tools , tackles , equipments etc. , labour, supervision and completing the work in all respect, at all heights as per drawings , specifications and instructions ofEngineer-in-charge. (Refer Legend for applicable EIL specification) 356 INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 357 INSULATION TYPE : CC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 358 PIPES 359 NB 00.75 INCHES; THICKNESS25 MM 360 NB 01.00INCHES; THICKNESS25 MM 361 NB 01.50 INCHES; THICKNESS50 MM 362 NB 02.00 INCHES; THICKNESS50 MM 363 NB 06.00INCHES; THICKNESS50 MM 364 NB 08.00INCHES; THICKNESS50 MM 365 NB 012.000INCHES; THICKNESS60 MM 366 NB 018.000INCHES; THICKNESS60 MM 367 NB 24.00 INCHES; THICKNESS60 MM 368 NB 28.00 INCHES; THICKNESS60 MM 369 NB 42.00 INCHES; THICKNESS60 MM 370 FLANGE ASSEMBLIES 371 NB 00.75INCHES; THICKNESS25 MM 372 NB 01.00INCHES; THICKNESS25 MM 373 NB 01.50 INCHES; THICKNESS50 MM 374 NB 02.00INCHES; THICKNESS50 MM 375 NB 06.00INCHES; THICKNESS50 MM 376 NB 08.00INCHES; THICKNESS50 MM 377 NB 012.000INCHES; THICKNESS60 MM 378 NB 018.000INCHES; THICKNESS60 MM 379 NB 24.00 INCHES; THICKNESS60 MM 380 NB 42.00 INCHES; THICKNESS60 MM 381 BLIND FLANGE ASSEMBLIES 382 NB 00.75 INCHES; THICKNESS25 MM 383 NB 08.00 INCHES; THICKNESS50 MM 384 VALVE ASSEMBLIES 385 NB 00.75 INCHES; THICKNESS25 MM 386 NB 01.00INCHES; THICKNESS25 MM 387 NB 01.50INCHES; THICKNESS50 MM 388 NB 02.00 INCHES; THICKNESS50 MM 389 NB 06.00INCHES; THICKNESS50 MM 390 NB 08.00 INCHES; THICKNESS50 MM 391 NB 012.000INCHES; THICKNESS60 MM 392 NB 018.000INCHES; THICKNESS60 MM 393 NB 24.00 INCHES; THICKNESS60 MM 394 NB 42.00 INCHES; THICKNESS60 MM 395 INSULATION TYPE : SC; SURFACE MATERIAL : CS & AS; OPERATING TEMP. RANGE : UPTO -45 (DEG C); INSULATION MATERIAL : PREFORMED POLYISOCYANURATE RIGID FOAM(PIR) 396 PIPES 397 NB 00.50 INCHES; THICKNESS25 MM 398 NB 00.75 INCHES; THICKNESS25 MM 399 NB 01.00 INCHES; THICKNESS25 MM 400 NB 01.50 INCHES; THICKNESS25 MM 401 NB 02.00 INCHES; THICKNESS25 MM 402 NB 03.00 INCHES; THICKNESS25 MM 403 NB 04.00 INCHES; THICKNESS40 MM 404 NB 06.00 INCHES; THICKNESS25 MM 405 NB 06.00 INCHES; THICKNESS40 MM 406 NB 08.00 INCHES; THICKNESS25 MM 407 NB 08.00 INCHES; THICKNESS40 MM 408 NB 12.00 INCHES; THICKNESS40 MM 409 NB 18.00 INCHES; THICKNESS40 MM 410 NB 24.00 INCHES; THICKNESS40 MM 411 NB 24.00 INCHES; THICKNESS50 MM 412 NB 28.00 INCHES; THICKNESS50 MM 413 NB 42.00 INCHES; THICKNESS50 MM 414 FLANGE ASSEMBLIES 415 NB 00.50INCHES; THICKNESS25 MM 416 NB 00.75INCHES; THICKNESS25 MM 417 NB 01.00INCHES; THICKNESS25 MM 418 NB 01.50 INCHES; THICKNESS25 MM 419 NB 02.00 INCHES; THICKNESS25 MM 420 NB 03.00INCHES; THICKNESS25 MM 421 NB 04.00INCHES; THICKNESS40 MM 422 NB 06.00 INCHES; THICKNESS25 MM 423 NB 06.00 INCHES; THICKNESS40 MM 424 NB 08.00INCHES; THICKNESS25 MM 425 NB 08.00INCHES; THICKNESS40 MM 426 NB 12.00 INCHES; THICKNESS40 MM 427 NB 018.000INCHES; THICKNESS40 MM 428 NB 24.00 INCHES; THICKNESS40 MM 429 NB 24.00 INCHES; THICKNESS50 MM 430 NB 42.00 INCHES; THICKNESS50 MM 431 BLIND FLANGE ASSEMBLIES 432 NB 00.75 INCHES; THICKNESS25 MM 433 NB 01.00 INCHES; THICKNESS25 MM 434 NB 01.50 INCHES; THICKNESS25 MM 435 NB 02.00 INCHES; THICKNESS25 MM 436 NB 08.00 INCHES; THICKNESS40 MM 437 NB 24.00 INCHES; THICKNESS50 MM 438 VALVE ASSEMBLIES 439 NB 00.50 INCHES; THICKNESS25 MM 440 NB 00.75 INCHES; THICKNESS25 MM 441 NB 01.00 INCHES; THICKNESS25 MM 442 NB 01.50 INCHES; THICKNESS25 MM 443 NB 02.00 INCHES; THICKNESS25 MM 444 NB 03.00 INCHES; THICKNESS25 MM 445 NB 04.00 INCHES; THICKNESS40 MM 446 NB 06.00INCHES; THICKNESS25 MM 447 NB 06.00INCHES; THICKNESS40 MM 448 NB 08.00 INCHES; THICKNESS25 MM 449 NB 08.00 INCHES; THICKNESS40 MM 450 NB 12.00 INCHES; THICKNESS40 MM 451 NB 018.000INCHES; THICKNESS40 MM 452 NB 24.00 INCHES; THICKNESS40 MM 453 NB 24.00 INCHES; THICKNESS50 MM 454 NB 42.00 INCHES; THICKNESS50 MM 455 ELECTRICAL WORKS 456 Design, detailed engineering, preparation of documents, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, preparation of graphics for the total microprocessor based analogue addressable type fire detection & alarm system including supply of required software, packing, delivery of the following, including supply of all commissioning spares & special tools and tackles, erection material & documentation as per the enclosed EIL standard specifications, scope of work/job specification, data sheets etc. and other codes and standards attached or referred. 457 8-loop microprocessor based DGFAP with HMI with battery &charger (refer block diagram) 458 Microprocessor based Repeater panel with battery and charger (refer block diagram) 459 Multi - sensor type addressable detectors with junction boxes for safe area 460 Intrinsically safeHeat Detector-addressable type 461 Addressable Linear Beam detectors with transmitter, receiver, reflector for safe area. 462 Zener barrier 463 Outdoor weather proof addressable Break Glass Unit (BGU)/Manual call point (IP-65)in safe area. 464 Indoor addressable Break Glass Unit (BGU) in safe area. 465 Addressable type electronic hooter with minimum 6W output 466 Wall mounting type one faced exit signs suitable for indoor location 467 Ceiling mounting type double faced exit signs suitable for indoor location 468 Weather proof (IP-65) Fault Isolating Modules for loops connecting outdoor break glass units 469 Fault Isolating Modules for loops connecting indoor break glass units/detectors/hooters etc. 470 Control modules with integral junction box installed within loop 471 Input Module with integral junction box installed within loop 472 Industrial type 5 km diametrical range siren with Siren control & starter panel 473 Response indicator for rooms and concealed area for Addressable Fire alarm system 474 Hooter acknowledge Box 475 Providing training for TWO Nos. OWNERs Engineers for a period of 4 days at manufacturer works for Fire Alarm system 476 Providing training for FIVE Nos. OWNERs Engineers at site for the complete fire alarm system 477 Mandatory spares for Fire Alarm system as perCl.6.1 (Mandatory spares), sr.no.15 of EDB document no. B861-000-16-50-EDB-1001 478 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wallmounting type Analogue caller ID telephone handsets (corded landline phones) with numeric key pad and redialling facility complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-ChargeExisting exchange distribution boxes make is ADC Krone, UK 479 Supply, inspection at shop, delivery at site of safe area weatherproof/ indoor push button type desktop/ wall mounting type Analogue non caller ID telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.Existing exchange distribution boxes make is ADC Krone, UK 480 Installation, testing and commissioning of safe area weatherproof/ indoor push button type desktop/ wall mounting type telephone handsets complete with all accessories including all labour and materail. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 481 Design, detailed engineering, manufacture, preparation of documents, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, supply & delivery of plant communication system supply of all commissioning spares and special tools & tackles, erection & installation material & documentation as per the enclosed EIL specifications, Job specifications/scope of work, datasheets etc and other codes & standards attached or referred. 482 Desktop type Master Call Station (Central Control Unit withMain Master Control Controller with Gooseneck MIC and All Call & Inter-MCD Call facility) with 24 keys suitable for connection with existing 16 Way Microprocessor based Central Control Exchange of DD Electronic Equipment’s PVT Ltd make.Make & model no. of Desktop type Master call station shall be same/ similar make as that of existing.Existing make is DD Electronic Equipment’s PVT Ltd with Model No: LDD8950/20 483 480W BOOSTER AMPLIFIER UNIT including all accessories such as zonal relay cards, IOs, interconnection cables etc. suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing.Existing make is BOSCH with Model No: LBD 1938 484 Weather proof IP-65 loud speaker 15/20 Watt suitable for integration with existing exchange of make DD equipments. Make & Model no. of Booster amplifier unit shall be same/similar make as that of existing. Existing make & model no. is Make – DNH ; Model - HS15T 485 Supply, installation and connection of CU earth plates ( 380x45x10) size, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in- Charge. 486 Unit Rates for UPS ACDB feeders/components 487 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A with Isolation Transformer 488 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A with Isolation Transformer 489 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A with Isolation Transformer 490 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU upto 32 A without Isolation Transformer 491 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 63 A without Isolation Transformer 492 Supply, mounting & wiring of fully equipped outgoing feeder 230V SFU 100 A without Isolation Transformer 493 supply& connection of 300A, 230V ACDB Vertical Empty Panel along with bus bar 494 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 16 A with 230/240V step up transformer) 495 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 32 A with 230/240V step up transformer) 496 Supply, mounting & wiring of Fully equipped outgoing feeder (230V SFU 63 A with 230/240V step up transformer) 497 Supply, mounting & wiring of 100A switch 498 Supply, mounting & wiring of 63A switch 499 Supply, mounting & wiring of 32A switch 500 Supply, mounting & wiring of 100A semiconducting fuse 501 Supply, mounting & wiring of 63A semiconducting fuse 502 Supply, mounting & wiring of 32A semiconducting fuse 503 Supply, mounting & wiring of 100A HRC fuse 504 Supply, mounting & wiring of 63A HRC fuse 505 Supply, mounting & wiring of 32A HRC fuse 506 Supply, mounting & wiring of 6 kVA 230V/230V Isolating Transformer 507 Supply, mounting & wiring of 5 kVA 230V/230V Isolating Transformer 508 Supply, mounting & wiring of 4 kVA 230V/230V Isolating Transformer 509 Supply, mounting & wiring of 3 kVA 230V/230V Isolating Transformer 510 Supply, mounting & wiring of 2 kVA 230V/230V Isolating Transformer 511 Supply, mounting & wiring of 1 kVA 230V/230V Isolating Transformer 512 Unit rates for 110V DCDB feeders/components 513 supply& connection of 350A, 110V DCDB Vertical Empty Panel along with bus bar 514 Supply, mounting & wiring of 63A, 110V DC SFU fully equipped outgoing feeder 515 Supply, mounting & wiring of 32A, 110V DC SFU fully equipped outgoing feeder 516 Supply, mounting & wiring of 16A, 110V DC SFU fully equipped outgoing feeder 517 Supply, mounting & wiring of 32A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 518 Supply, mounting & wiring of 16A, 110V DC SFC (switch fuse+ contactor) fully equipped outgoing feeder 519 Supply, mounting & wiring of 100A, 110V DC Switch 520 Supply, mounting & wiring of 63A, 110V DC Switch 521 Supply, mounting & wiring of 32A, 110V DC Switch 522 Supply, mounting & wiring of 16A, 110V DC Switch 523 Supply, mounting & wiring of 100A, 110V DC fuse Link 524 Supply, mounting & wiring of 63A, 110V DC fuse Link 525 Supply, mounting & wiring of 32A, 110V DC fuse Link 526 Supply, mounting & wiring of 16A, 110V DC fuse Link 527 Supply, mounting & wiring of 100A, 110V DC contactor 528 Supply, mounting & wiring of 63A, 110V DC contactor 529 Supply, mounting & wiring of 32A, 110V DC contactor 530 Supply, mounting & wiring of 16A, 110V DC contactor 531 TRANSFORMERS 532 Installation of transformers of the following ratings excluding the construction of foundation, includingtransportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, including connection of auxiliary circuits, topping up with oil and testing of oil with contractors own test equipment, including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 533 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 534 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 535 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 536 Filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength,including all labour and materials,specifications of this tender and directions of Engineer-in-Charge.(Excluding the supply of oil). 537 Filtration of transformer oil with dissolved gas analysis test. 538 Filtration of transformer oil without dissolved gas analysis test. 539 Supply of transformer oil conforming to IS-335 in non-returnable 220 litre drums for topping up various transformers. The oil shall be tested prior to filling up and improved by filtering, if required, including all labour and materials,specifications of this tender and directions of Engineer-in-Charge. 540 No. of Drums. 541 Supply of dry type transformers with accessories,including nuts and bolts etc., as per EIL standard specification No. 6-51-0042, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 542 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 543 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 544 Installation, testing and commissioning of dry transformer of following rating, including transportation from store/yard to site at the place of installation, unpacking, positioning in place, site assembly of loosely furnished accessories, connection of auxiliary circuits,including fixing of nuts and bolts etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 545 2 Winding Dry type transformers. .415 kV/ .415 kV75 kV·A 546 2 Winding Dry type transformers. .415 kV/ .415 kV160 kV·A 547 Testing and commissioning of transformers of the following rating including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. 548 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV2.5 MV·A 549 2 Winding ONAN outdoor transformer with off circuit tap changer. 11 kV/ .433 kV1.6 MV·A 550 2 Winding ONAN/ONAF outdoor transformer with OLTC. 11 kV/ 6.9 kV6.3 MV·A 551 SWITCHBOARDS / UPS / VSD / BATTERY CHARGERS / PANELS 552 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 553 Weight of the Unit upto 100 kg. 554 Weight of the Unit from 101 upto 500 kg. 555 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc. electrical panels etc., including transportation from store/yard to site at the place of installation, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor etc., interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineers-in-Charge. 556 Weight of the Unit upto 100 kg. 557 Weight of the Unit from 101 upto 500 kg. 558 Installation, testing and commissioning of bus ducts of following ratings between transformer secondary and the switchgear incomer panel, including transportation from store/yard to site at the place of installation, unpacking, making connections and installation of bends, breaking of walls and making good of the same etc., (but excluding structural supports), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 559 Air Insulated/segregated bus ducts 415 V4000 A65 kAfor 1 second 560 Air Insulated/segregated bus ducts 415 V2500 A65 kAfor 1 second 561 Installation, testing and commissioning of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 562 Weight of the Unit upto 100 kg 563 Weight of the Unit from 101 upto 500 kg. 564 Weight of the Unit from 501 upto 1000 kg. 565 Weight of the Unit from 1001 upto 1500 kg. 566 Weight of the Unit from 1501 upto 3000 kg. 567 Installation of switch-boards, relay and control panels, annunciation panels, UPS system, battery chargers, distribution boards, cubicles with electrical equipment, VSD panels, misc .electrical panels etc., including transportation from store/yard to site at the place of installation, lifting the panels by deployment of tyre mounted hydraulic trollies, unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of all wiring materials, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing and calibration of relays and meters etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 568 Weight of the Unit upto 100 kg 569 Weight of the Unit from 101 upto 500 kg. 570 Weight of the Unit from 501 upto 1000 kg. 571 Weight of the Unit from 1001 upto 1500 kg. 572 Weight of the Unit from 1501 upto 3000 kg. 573 Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery to site including all labour and materials along with supply of special tools & tackles for following Single Phase, 50 Hz UPS System along with associated accessories and AC Distribution Board complete with documentations as per approved drawings, specifications, data sheets and other codes & standards attached or referred with this tender and directions of Engineer-in-charge. 574 55KVA, 230V, 50 Hz, SPNParallel Redundant UPS withBypass as data sheet DS-440 575 1X100% NI-CD Battery Bank for 30 Min. backup along with all accessories & battery Isolator. 576 230V, 300 Amps, 50 Hz, AC Distribution Board as per Feeder Details listed in scope of work/job specification 577 Cell booster of adequate rating suitable for battery AH capacity. 578 Providing training to 2 nos. owners engineer at Vendor Works for a period of min. 3 days for 55KVA UPS system 579 Providing training to 5 nos. owners engineers at site for 55KVA UPS system 580 Mandatory spares for 230V, 55KVA UPS system as perCl.6.1 (Mandatory spares), sr.no.10 of EDB document no. B861-000-16-50-EDB-1001 581 MISCELLANEOUS CONTROL GEAR 582 Installation, testing and commissioning of miscellaneous surface mounted industrial/FLP control gear such as lighting/power panel, push button stations, motor starter, communication equipment, junction boxes, panels, plugs, sockets, including supply of necessary hardware, touch up painting including supply of paint, including transportation from store/yard to site at the place of installation, unpacking, (excluding fixing of cable glands and cable terminations),including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 583 Weight of the unit above 5 kg. but upto 20 kg. 584 Weight of the unit above 20 kg. but upto 100 kg. 585 Weight of the unit up to 5 kg. 586 Supply of Industrial, weather proof type Push Button stations as per EIL specification No. 6-51-0014, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 587 With stop (latching type) push button. 588 With stop (non-latching type) push button. 589 With start and stop (latching type) push buttons. 590 With start, stop push buttons and ammeter. 591 With start,stop push buttons and one Three position selector switch. 592 With start,stop push buttons, one Three position selector switch and ammeter. 593 With stop push button (Break Glass Type). 594 With start and stop (non-latching type) push buttons. 595 Supply of flameproof and weather proof type Push Button station as per EIL standard specification No. 6-51-0006 as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 596 With start, stop push buttons and one Three position selector switch and ammeter. 597 DC SYSTEM / BATTERY BANK 598 Supply of following ratings of Nickel-cadmium batteries, battery charger, distribution board alongwith accessories as per EIL specification No. 6-51-0019, 6-51-0047, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 599 160A (Min.) , dual redundant battery charger as per data sheet DS-430 600 110V, 1x500AH(Min.), Ni-Cd battery bank 601 110V, 350A DC distribution board as per feeder details listed in scope of work/job specification 602 3P MCCB / DC Circuit Breaker Battery isolator in weatherproof enclosure(IP-55)of adequate rating. 603 Mandatory spares for 110V Battery & Battery charger as per Cl.6.1 (Mandatory spares), sr.no.11 of EDB document no. B861-000-16-50-EDB-1001 604 Installation, testing and commissioning of stationary nickel-cadmium battery banks of the following ratings, including transportation from store/yard to site at the place of installation, filling with electrolyte, charging and dischargng of cells, including capacity test etc., aligning, levelling, grouting, assembly of battery racks, fixing of inter-cell connectors etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 605 Nickel-cadmium battery banks (including capacity test) rated for 110 V500 Ah 606 Supply of following rating of cell boosters as per EIL specification No. 6-51-0019, including all labour and materials, as per data sheets, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 607 Cell booster rated for 12 V50 A 608 PLUGS, SOCKETS AND JUNCTION BOXES 609 Supply of weatherproof metal clad 415V, TPN, industrial type socket and plug with heavy duty interlocking switch, with adequately sized cable adaptor box for incoming and outgoing cable terminations, including supply of double compression brass nickel plated cable glands, tinned copper lugs,including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 610 63 A, 415 V, 5 pin sockets along with associated 5 pin plugs. 611 240 V, 15 A, 3 pin sockets. 612 240 V, 15 A, 3 pin sockets along with associated 3 pin plugs. 613 24 V, 5 A, 3 pin sockets along with associated 3 pin plugs. WITH TRANSFORMER.(240/24V) 614 Supply, installation, cable termination, connection, testing and commissioning of following types of FLP andWP junction boxes, as per EIL specification No. 6-51-0061, including all labours and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 615 WP JB (IP-65) with 15 A, 16 terminals suitable for 1 No. incoming and6 Nos. outgoing cable entries complete with cable glands for incoming and outgoing cables and 3 Nos. blocking plugs 616 WP 3 way JB (IP-65) complete with 3 Nos. cable glands and 1 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 617 WP 4 way JB with IP-65 degree of protection complete with 4 Nos. cable glands and 2 Nos. blocking plug suitable for cables upto 3 x 2.5 sq. mm YWY / XWY cable. 618 NEUTRAL GROUNDING RESISTOR 619 Supply of following rating of outdoor type neutral grounding resistor, as per EIL standard specification no.6-51-0043,including all labour and materials, as per approved drawings, specifications of this tnder and directions of Engineer-in-Charge. 620 NGR rated for 3.81 kV400 A 621 Installation, testing and commissioning of outdoor type following neutral grounding resistor consisting of cast iron/stainless steel grid resistor with/without neutral CT including connection of one end of resistor with transformer neutral and the other end of the resistor to the earthing grid, including transportation from store/yard to site at the place of installation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 622 NGR rated for 3.81 kV400 A 623 CAPACITOR BANKS 624 Supply of following HV capacitor banks, series reactor and RVT, as per EIL standard specification NO. 6-51-0020, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 625 11kV, 3 Phase,indoor type APFC panel -1500kVAR 626 Mandatory spares for APFC as per Cl.6.1 (Mandatory spares), sr.no.20 of EDB document no. B861-000-16-50-EDB-1001 627 Installation of following H.V. capacitor banks,series reactor and RVT, including transportation from store/yard to site ofinstallation, unpacking, assembly of elevating structure, interconnection of loose parts supplied by equipment vendor, aligning, levelling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 628 HV capacitor banks rated for 1500 kVAR11 kV 629 Testing and commissioning of following H.V. capacitor banks,series reactor and RVT, including testing equipments, all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 630 HV capacitor banks rated for 1500 kVAR11 kV 631 CANOPIES 632 Supply, fabrication and installation of FRP canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 633 Lighting Panel/Power panel/distribution junctions boxes. 634 Manual call points/field call stations. 635 Push button stations. 636 Supply, fabrication andinstallation of canopies for miscellaneous outdoor equipment like motors, fire alarm points, telephones, communication hand set stations etc. to render them weatherproof made out of 1.6 mm (16 gauge) sheet steel including supply of hardware and paint, painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 637 Supply, fabrication andinstallation of GI canopies for outdoor electrical motors of following frame sizes to render them weather proof including supply of necessary hardware for fixing and clamping with the motor foundation, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 638 Frame size upto 80. 639 Frame size more than 80 and upto 112. 640 Frame size more than 112 and upto 180. 641 Frame size more than 180 and upto 250. 642 Supply, fabrication and installation of GI canopies for outdoor electrical miscellaneous equipments such as lighting/power panels and distribution junction boxes, local panels , PB stations etc. to render them weather proof including supply of necessary hardware for fixing and clamping with the equipment, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 643 Lighting Panel/Power panel/distribution junctions boxes. 644 Manual call points/field call stations. 645 Push button stations. 646 FLP receptacles. 647 ANCHOR FASTENERS 648 Supply, drilling in RCC and fixing of metallic anchor fasteners for supporting of cable trays and miscellaneous electrical switchgear of following sizes, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 649 3/16 BSW. 650 5/16 BSW. 651 1/4 BSW. 652 3/8 BSW. 653 5/8 BSW. 654 1/2 BSW. 655 SAFETY EQUIPMENT 656 Supply and installation of the following, including the supply of necessary clamps, bolts, rawl plugs etc., breaking and making good of walls, if required, mounting, including all labour and materials, complete and as per applicable standards and CEA Guidelines and as per directions of Engineer-in-Charge. 657 Shock hazard charts complete with frame and glass. 658 First Aid Boxes. 659 4.5 kg capacity CO2 type fire extinguishers. 660 6.8 kg capacity CO2 type fire extinguishers. 661 9 kg capacity CO2 type fire extinguishers. 662 Sand buckets with stand (Each with at least 3 sand buckets). 663 Shock hazard charts - Laminated type 664 Gas Mask for use in substation during fire & smoke as per CEA guidelines 665 Supply and laying of 900 mm wide safety insulation mats complying to IS-15652, of following grades required for maintenance of electrical equipment in substation, including cutting to required shape in running length, including all labour and materials, as per applicable Indian or International standards and CEA Guidelines and as per directions of Engineer-in-Charge. 666 3.3 kV grade. 667 11 kV grade. 668 Supply of following items as per applicable Indian standards/CEA Guidelines. 669 Rubber hand gloves (11 kV grade). 670 Rubber hand gloves (33 kV grade). 671 Enamelled caution boards. 672 Discharge rod with earthing facility (upto 11 kV grade). 673 HV fuse puller handle. 674 Supply and application/installation of epoxy based insulation coating with breakdown voltage as per IS, suitable for system voltage as marked and shall be suitable for installation on concrete flooring of substation in airconditioned/non-airconditioned area, having smooth finish, including all labour and materials, complete as per approved drawings, job & standard specification attached with this tender and directions of the engineer-in- charge 675 For highest systen voltage of 12.1kV 676 SUPPLY OF SPARES / LAMPS 677 MV HRC Fuses 678 16 A. 679 32 A. 680 63 A. 681 100 A. 682 160 A. 683 250 A. 684 SUPPLY OF MV CABLES 685 Supply of 1100 V grade, Copper Conductor,XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 686 2 C x 10 sq. mm 687 2C x 16 sq. mm 688 2 C x 2.5 sq. mm 689 3 C x 6 sq. mm 690 2 C x 4 sq. mm 691 3 C x 4 sq. mm 692 3 C x 10 sq. mm 693 3 C x 2.5 sq. mm 694 Supply of 1100 V grade, Aluminium Conductor, XLPE insulated and armoured, cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 695 3 C x 25 sq. mm 696 3.5 C x 25 sq. mm 697 3 C x 35 sq. mm 698 2 C x 50 sq. mm 699 3 C x 95 sq. mm 700 3 C x 120 sq. mm 701 3.5 C x 185 sq. mm 702 3 C x 240 sq. mm 703 3 C x 50 sq. mm 704 3.5 C x 35 sq. mm 705 3.5 C x 95 sq. mm 706 3.5 C x 300 sq. mm 707 3.5 C x 50 sq. mm 708 3.5 C x 120 sq. mm 709 Supply of 1100 V grade, Copper Conductor, Individual pair shielded & Overall shielded, twisted pair/triad, XLPE insulated, Armored, FRLS outer-sheathed cables of following sizes as per EIL standard specification No. 6-51-0052, data sheets, specifications of this tender and directions of Engineer-in-Charge. 710 1 Pair x 2.5 sq. mm 711 2 Pair x 2.5 sq. mm 712 4 Pair x 2.5 sq. mm 713 6 Pair x 2.5 sq. mm 714 12 Pair x 2.5 sq. mm 715 SUPPLY OF HV CABLES (MULTI CORE) 716 Supply of 6.6 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 717 3 C x 240sq. mm, Al 718 Supply of 11 kV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured cables of following sizes as per EIL standardspecification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 719 3 C x 240 sq. mm, Al 720 3 C x 300 sq. mm, Al 721 SUPPLY OF HV CABLES (SINGLE CORE) 722 Supply of 6.6 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 723 1 C x 630 sq. mm, Al 724 Supply of 11 KV (UE) grade, Al/Cu Conductor, XLPE insulated and armoured single core cables of following sizes as per EIL standard specification No. 6-51-0051, data sheets, specifications of this tender and directions of Engineer-in-Charge. 725 1 C x 630 sq. mm, Al 726 LAYING OF CABLES 727 Laying of cables of different voltage grade and types of the following overall diameters in ready trays/trenches/ supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 728 Cables with OD above 80 mm but upto 100 mm. 729 Cables with OD above 50 mm but upto 60 mm. 730 Cables with OD above 60 mm but upto 80 mm. 731 Cables with OD above 30 mm but upto 40 mm. 732 Cables with OD above 20 mm but upto 30 mm. 733 Cables with OD upto 20 mm. 734 Cables with OD above 40 mm but upto 50 mm. 735 Laying of cables (using cable pulling by motorized winch with torque limits) of different voltage grade and types of the following overall diameters in ready trays/trenches/supported on structure/pull through pipes including supply and fixing of stainless steel strip number tags, supply and fixing of GI saddles & saddle bars, trefoil clamps (for single core cables) etc., including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 736 Cables with OD upto 20 mm. 737 Cables with OD above 20 mm but upto 30 mm. 738 Cables with OD above 30 mm but upto 40 mm. 739 Cables with OD above 40 mm but upto 50 mm. 740 Cables with OD above 50 mm but upto 60 mm. 741 Cables with OD above 60 mm but upto 80 mm. 742 Cables with OD above 80 mm but upto 100 mm. 743 END TERMINATIONS 744 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per IEC-60331, specifications of this tender and directions of Engineer-in- Charge. (Actual area of surface painted shall be measured). 745 Supply of Unearthed grade H.V. termination kits of (indoor/outdoor type) as per EIL standard specification No. 6-51-0051, excluding cable glands and lugs, as per approved drawings and as per specifications of this tender and directions of Engineer-in-Charge. 746 3 Core cable Indoor termination kit for 6.6 kV240 mm² 747 3 Core cable Outdoor termination kit for 6.6 kV240 mm² 748 3 Core cable Indoor termination kit for 6.6 kV300 mm² 749 3 Core cable Indoor termination kit for 11 kV300 mm² 750 3 Core cable Indoor termination kit for 11 kV240 mm² 751 1 Core cable Indoor termination kit for 6.6 kV630 mm² 752 1 Core cable Indoor termination kit for 11 kV630 mm² 753 Termination of Unearthed grade HV cables and connection of leads including fixing of cable glands,supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug onto the conductor, restoration of the insulation, clamping of cable cores and earthing of armour, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excluding supply of termination kits and cable glands). 754 3 Core cable termination kit for 6.6 kV300 mm² 755 3 Core cable termination kit for 6.6 kV240 mm² 756 3 Core cable termination kit for 11 kV300 mm² 757 3 Core cable termination kit for 11 kV240 mm² 758 1 Core cable termination kit for 6.6 kV630 mm² 759 1 Core cable termination kit for 11 kV630 mm² 760 Termination of XLPE insulated armoured power cables (up to 1100 V grade) and connection of leads excluding the supply of cable glands and lugs but includingfixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations, cutting and stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable-cores, marking with wire number, ferrules etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 761 Cables with OD above 60 mm but upto 80 mm. 762 Cables with OD above 40 mm but upto 50 mm. 763 Cables with OD above 30 mm but upto 40 mm. 764 Cables with OD above 50 mm but upto 60 mm. 765 Cables with OD upto 20 mm. 766 Cables with OD above 20 mm but upto 30 mm. 767 Termination of communication, fire alarm & control paired cables and connection of leads excluding the supply of cable glands and lugs but including fixing of cable glands, supply and fixing of PVC shrouds for outdoor terminations,cutting, stripping of cable insulation, crimping the lug on to the conductor, clamping of the cable- cores, marking with wire number, ferrules etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 768 All sizes from 1P to 4P and upto 2.5 sq. mm 769 All sizes from 5P to 10P and upto 2.5 sq. mm 770 All sizes from 11P to 15P and upto 2.5 sq. mm 771 STRAIGHT THROUGH JOINTS 772 Supply and Making of heat shrinkable type straight through joints for 1100 volt grade power cablesas per EIL standard specification No. 6-51-0051, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 773 Cables with OD above 30 mm but upto 40 mm. 774 Cables with OD above 50 mm but upto 60 mm. 775 Cables with OD above 60 mm but upto 80 mm. 776 Cables with OD upto 20 mm. 777 Cables with OD above 40 mm but upto 50 mm. 778 Cables with OD above 20 mm but upto 30 mm. 779 Supply of heat shrinkable type Straight through jointing kits for Unearthed grade H.V. cables of the following sizes,as per EIL standard specification No. 6-51-0051, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 780 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 781 3 Core cable Straight through jointing kits for 11 kV300 mm² 782 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 783 1 Core cable Straight through jointing kits for 11 kV630 mm² 784 Making of Straight through joints for H.V. cables of following sizes excluding supply of jointing kit and accessories, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 785 3 Core cable Straight through jointing kits for 6.6 kV240 mm² 786 3 Core cable Straight through jointing kits for 11 kV300 mm² 787 1 Core cable Straight through jointing kits for 6.6 kV630 mm² 788 1 Core cable Straight through jointing kits for 11 kV630 mm² 789 Supply and Making of heat shrinkable type straight through joints for communication, fire alarm & control paired cables, including cutting, stripping of cable insulation complete with supply of compression / crimping type ferrules, plastic mould and epoxy resin compound etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 790 All sizes from 5P to 10P and upto 2.5 sq. mm 791 All sizes from 11P to 15P and upto 2.5 sq. mm 792 All sizes from 1P to 4P and upto 2.5 sq. mm 793 G.I. & PVC PIPES 794 Supply and laying of following sizes ofG.I. Pipes (medium) in required length fixed on steel, concrete or similar structure, laid in trenches, ready to be buried in concrete including cutting, threading, bending and similar works, supply of clamps, small iron structures, spacers and installation of seats, plugs, bushings etc., small civil works, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 795 100 mm NB. 796 150 mm NB. 797 50 mm NB. 798 STRUCTURAL STEEL 799 Supply, fabrication, galvanising andinstallation of base frames, supports for switchgear, and brackets for miscellaneous electrical equipments, cable and cable tray supports out of rolled MS sections, pipes, plates etc. including welding, bolting, rivetting, supply of necessary anchor bolts and grouting etc., including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Any item weighing up to 1 kg. or less shall neither be measured nor paid). 800 CABLE - TRAYS 801 Supply and installation of prefabricated hot dip galvanised steel cable trays, fabricated out of hot rolled sheet steel with rigid welded construction ladder type with a rung as per std. 7-51-0333, of approved make and cable tray fittings, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 802 Reducers 750 - 450 RHS. 803 Reducers 750 - 600 RHS. 804 Reducers 750 - 600 LHS. 805 Horizontal bends for 450 mm wide tray with 1000 mm bending radius. 806 Horizontal bends for 600 mm wide tray with 1000 mm bending radius. 807 Vertical outside bends for 450 mm wide tray with 1000 mm bending radius. 808 Vertical outside bends for 600 mm wide tray with 1000 mm bending radius. 809 Vertical inside bends for 600 mm wide tray with 1000 mm bending radius. 810 Tee Joints for 450 mm wide tray with 1000 mm bending radius. 811 Tee Joints for 600 mm wide tray with 1000 mm bending radius. 812 Tee Joints for 750 mm wide tray with 1000 mm bending radius. 813 Cross Joints for 450 mm wide tray with 1000 mm bending radius. 814 Cross Joints for 750 mm wide tray with 1000 mm bending radius. 815 Vertical inside bends for 750 mm wide tray with 1000 mm bending radius. 816 300 mm wide Straight run cable tray. 817 Horizontal bends for 750 mm wide tray with 1000 mm bending radius. 818 Vertical outside bends for 750 mm wide tray with 1000 mm bending radius. 819 600 mm wide Straight run cable tray. 820 Reducers 750 - 300 RHS. 821 Reducers 600 - 300 RHS. 822 Horizontal bends for 300 mm wide tray with 1000 mm bending radius. 823 Vertical outside bends for 300 mm wide tray with 1000 mm bending radius 824 Vertical inside bends for 300 mm wide tray with 1000 mm bending radius 825 Tee Joints for 300 mm wide tray with 1000 mm bending radius. 826 450 mm wide Straight run cable tray. 827 750 mm wide Straight run cable tray. 828 Supply and installation of following galvanised slotted channel trays of 2 mm thickness and 50 mm high for supporting cables, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 829 150 mm wide. 830 60 mm wide. 831 100 mm wide. 832 Supply, fabrication andinstallation of 0.91 mm (20 gauge) GI sheet covers for cable trays, including necessary hardwares, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 833 CABLE GLANDS 834 Supply of nickel-plated, flame proof IIA/IIB double compression type brass cable glands, suitable for out door terminations of armoured PVC cables of following overall diameter (excluding termination and connection of cables), including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 835 Cables with OD above 50 mm but upto 60 mm. 836 Cables with OD above 30 mm but upto 40 mm. 837 Cables with OD above 40 mm but upto 50 mm. 838 Cables with OD above 60 mm but upto 80 mm. 839 Cables with OD above 20 mm but upto 30 mm. 840 Cables with OD upto 20 mm. 841 Supply of nickel plated brass double compression cable glands suitable for outdoor installations (WP) of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 842 Cables with OD upto 20 mm. 843 Cables with OD above 20 mm but upto 30 mm. 844 Cables with OD above 30 mm but upto 40 mm. 845 Cables with OD above 40 mm but upto 50 mm. 846 Cables with OD above 50 mm but upto 60 mm. 847 Cables with OD above 60 mm but upto 80 mm. 848 Supply of nickel plated brass single compression cable glands of following overall diameter (excluding termination and connections of cables), including drilling of suitable holes in equipments for fixing purposes etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 849 Cables with OD upto 20 mm. 850 Cables with OD above 20 mm but upto 30 mm. 851 Cables with OD above 30 mm but upto 40 mm. 852 Cables with OD above 40 mm but upto 50 mm. 853 Cables with OD above 50 mm but upto 60 mm. 854 Cables with OD above 60 mm but upto 80 mm. 855 Cables with OD above 80 mm but upto 100 mm. 856 Supply and fixing of FLP(IIA/IIB) blocking plugs for blocking unused cable entries with following diameter in outdoor electrical equipment including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 857 Cables with OD above 60 mm but upto 80 mm 858 Cables with OD above 30 mm but upto 40 mm 859 Cables with OD above 40 mm but upto 50 mm 860 Cables with OD above 50 mm but upto 60 mm 861 Cables with OD up to 20 mm 862 Cables with OD above 20 mm but upto 30 mm 863 MARKERS 864 Supply and installation of earth pit markers for directly buried GI pipe electrodes as per std. 7-51-0101 with 14 SWG enamelled steel plate engraved with white letters BURIED, EARTH ELECTRODE on JADE green background complete with support and foundation, including all labour and materials, as per approved drawings, specifications of this tender and direction of Engineer-in-Charge. 865 Supply and installation of cable markers as per std. 7-51-0301, for underground cable runs with 14 SWG enamelled steel plate with white lettering on jade green background inclusive of providing and fixing supports, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 866 CABLE LUGS 867 Supply of crimping type long barrel tinned copper lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 868 All sizes from 50 to 185 sq. mm 869 All sizes from 16 to 35 sq. mm 870 All sizes from 240 to 400 sq. mm 871 All sizes upto 10 sq. mm 872 All sizes from 500 to 1000 sq. mm 873 Supply of crimping type long barrel aluminium lugs with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 874 All sizes upto 10 sq. mm 875 All sizes from 240 to 400 sq. mm 876 All sizes from 16 to 35 sq. mm 877 All sizes from 50 to 185 sq. mm 878 All sizes from 500 to 1000 sq. mm 879 Supply of crimping type long barrel Bimetallic lugs with Al barrel & tinned Cu palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 880 All sizes from 50 to 185 sq. mm 881 All sizes from 240 to 400 sq. mm 882 All sizes upto 10 sq. mm 883 All sizes from 16 to 35 sq. mm 884 All sizes from 500 to 1000 sq. mm 885 Supply of crimping type long barrel Bimetallic lugs with tinned Cu barrel & Al palm with circular/sector shaped barrel for following conductor sizes, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 886 All sizes upto 10 sq. mm 887 All sizes from 16 to 35 sq. mm 888 All sizes from 240 to 400 sq. mm 889 All sizes from 50 to 185 sq. mm 890 All sizes from 500 to 1000 sq. mm 891 FIRE PROOFING OF CABLES 892 Fire proofing of cables including supply of all fire proofing paint, including all labour and materials, as per specifications of this tender and directions of Engineer-in-Charge. (Actual area of surface painted shall be measured). 893 ADAPTORS / REDUCERS / NIPPLES ETC. 894 Supply and fixing nickel-plated brass adaptors/ reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 895 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 896 Eqpt. Thread 1 PF (J.I.S.) - E.T. Thread 3/4ET 897 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 898 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 899 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 900 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 901 Supply and installation of GI reducers/enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 902 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 903 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 904 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 905 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 906 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 907 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 908 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 909 Eqpt. Thread 2 ET (IS) -E.T. Thread 1-1/2 ET 910 Supply and fixing FLP(IIA/IIB), weatherproof, nickel-plated brass adaptors/reducers for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 911 Eqpt. Thread 3/4 PF (J.I.S.)-E.T. Thread 3/4ET 912 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 3/4ET 913 Eqpt. Thread 1 PF (J.I.S.) -E.T. Thread 1ET 914 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/4ET 915 Eqpt. Thread 1-1/2 PF (J.I.S.)- E.T. Thread 1-1/2ET 916 Eqpt. Thread 2 PF (J.I.S.) -E.T. Thread 1-1/2ET 917 Supply and installation of FLP(IIA/IIB) GI reducers/ enlargers of following sizes for cable glands of following sizes including all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. Adaptors shall have male part threaded as per Eqpt. threads and the other end to receive glands having E.T. thread. 918 Eqpt. Thread PG 13.5(DIN) - E.T. Thread 3/4 ET 919 Eqpt. Thread PG 16 (DIN) -E.T. Thread 3/4 ET 920 Eqpt. Thread PG 21 (DIN) -E.T. Thread 1ET 921 Eqpt. Thread PG 29 (DIN) -E.T. Thread 1-1/2 ET 922 Eqpt. Thread 1 ET (IS) -E.T. Thread 3/4 ET 923 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1 ET 924 Eqpt. Thread 1-1/2 ET (IS) -E.T. Thread 1-1/2 ET 925 LIGHTING POLES 926 Supply and installation of Lighting Poles for floor mounting as per std. 7-51-0201, including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 927 Lighting poles including supply and connection of wires upto fixtures for safe areas. 928 Supply andinstallation of platform Lighting pole as per std. 7-51-0202,including all welding, structural works, paint and all sundry materials as required, including painting, (excluding supply and installation of control gear box/junction box), but including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 929 Lighting poles including supply and connection of wires upto fixtures for safe areas. 930 Supply andinstallation of street lighting poles (single bracket/double bracket) including built in marshalling box andnecessary wire/cable running from marshalling box to the lighting fixture, cable termination and connection, fixing of cable glands and lugs,including all civil works, excavation, foundation, disposal of surplus earth, providing shoring, strutting and dewatering if required and including supply of cement, steel, GI pipes, base plates, paint and all sundry materials as required, including painting, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 931 Poles as per std. 7-51-0233 with MB as per 7-51-0208 for safe area 932 Poles as per std. 7-51-0234 sht. 2 of 2 (Single bracket) 933 HAZARDOUS AREA LIGHTING FIXTURES AND ACCESSORIES 934 Installation, connection, testing and commissioning of following types of flame proof/Div.2 lighting fixtures and accessories, including cable termination and connection, fixing of cable glands, lugs, including supply of necessary hardwares, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 935 3-way, junction box. 936 4-way, junction box. 937 Well glass type pole mounting type for Ground Level. 938 Well glass type ceiling mounted. 939 Well glass type bracket mounted. 940 Well glass type pole mounting type for Platform. 941 Supply and installation of Type-`A clamps(for bracket mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamp as per EIL std.no.7-51-0221, including supply and fixing of anchor fasteners, nuts and bolts, washers etc. as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 942 Supply and installation of adapters for Platform and ground pole mounted lighting fixtures as per EIL std.no.7-51-0221, approved drawings, specifications of this tender and directions of Engineer-in-Charge. 943 Supply and installation of Type-`B clamps(for ceiling mounted lighting fixtures) including bolt (MOC SS304) for fixing the fixture to the clamps per EIL std.no.7-51-0221, including supply and fixing of anchor fastners,nuts and bolts,washers as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 944 SAFE AREA LIGHTING FIXTURES 945 Supply, installation, testing and commissioning of following energy efficient lighting fixtures and connecting to wiring junction box/marshalling box complete with lamps and necessary control gear including supply of all connected materials like flexible conduit, clamps, supports, chains, anchor fastners, bolts, nuts and washers etc. as required, including supply and fixing of cable glands, lugs, including all labour and materials, as per approved drawings, data sheet for lighting fixture schedule, EIL installation standards, specifications of this tender and directions of Engineer-in-Charge. 946 Type LED SFD-12 Fixtures. 947 Type LED BK-3 Fixtures. 948 Type LED ST-10 Fixtures. 949 Type LED FD-1 Fixtures. 950 Type LED FD-2 Fixtures. 951 Type LED FD-3 Fixtures. 952 JUNCTION BOXES (OUTDOOR / INDOOR TYPE) 953 Supply and installation of dust and vermin proof G.I. sheet steel (1.6 mm thick) junction box WP type suitable for outdoor/indoor installation with number of outgoing ways as under, complete with PVC connectors, supply and fixing of cable glands, including supply of required size and number of terminals, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 954 3 way. 955 4 way. 956 LIGHTING / POWER PANELS AND DISTRIBUTION BOARDS 957 Supply, installation, connection, testing and commissioning offlame proof weather proof lighting/power panels(for gas group IIA/IIB) as per EIL std. spec. 6-51-0008, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 958 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 959 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs with ELCB (upto 20 A). 960 Supply, installation, connection, testing and commissioning of safe area lighting/power panels, surface/flush mounting type, wall mounting type in dust tight (with hinged cover) sheet steel enclosure having 4 pole incomer and single pole MCB (9 kA type) for outgoing circuit control with completewiring, including cable termination, connection and fixing of cable glands, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 961 40 A, 4 pole incomer MCB isolator and 6 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 962 40 A, 4 pole incomer MCB isolator and 12 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 963 63 A, 4 pole incomer MCB isolator and 18 Nos. outgoingdouble poleMCBs (upto 20 A) with RCCBs in each outgoing circuits suitable for outdoor location with IP-65 degree of protection 964 WIRING 965 Circuit wiring in non-hazardous areas using (size given below), copper conductor, PVC insulated, FRLS outer sleeve cables (third core for earthing),from lighting/powerpanel/distribution junction box, excluding the supply of cable, junction boxes and cable glands but including termination and connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 966 3 C x 2.5 sq. mm 967 3 C x 4 sq. mm 968 Circuit wiring in hazardous areas using (sizes given below) copper conductor, XLPE insulated, FRLS outer sleeve armoured cables (third core for earthing) from lighting/power panel/distribution junction box onwards, excluding the supply of cables, junction boxes and cable glands but including fixing of cable glands, supply and fixing of clamps, cable terminations and connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 969 3 C x 2.5 sq. mm 970 EARTH ELECTRODES 971 Supply, installation, testing and commissioning of GI earth electrodes, complete with earth pit as per std. 7-51-0102 and all necessary materials including excavation of earth pit, filling with charcoal and salt, back filling, providing necessary brickwork, connections, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 972 GI earth electrode as per std. 7-51-0102. 973 COPPER EARTH ELECTRODES 974 Supply, installation, testing and commissioning of Cu earth electrodes complete with 38 mm outer dia x 3 mm thick Cu pipe in a depth of 25Mtr, 3mm Thick 4Inch X 12 Inch Copper plate, earth pit and all necessary materials including excavation of earth pit, filling with charcoal and salt, bentonite powder, back filling, providing necessary brickwork, connections, including all labour and materials, as per sketch B861-000-16-50-DS-4001, approved drawings, specifications of this tender and directions of Engineer-in-Charge 975 EARTH STRIPS 976 Supply, installation and connection of following GI earthing strip along the cable trenches or cable trays or fixing to walls or structures including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 977 100 X 12 mm 978 40 x 5 mm 979 25 x 3 mm 980 50 x 6 mm 981 Supply, installation and connection of following GI earthing strip buried individually at a depth of 500 mm including welding at joints, providing anti-corrosive paint or bitumen and jute covering for welded portion, clamping and necessary hardware for connecting, excavation and refilling etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 982 100 X 12 mm 983 40 x 5 mm 984 25 x 3 mm 985 50 x 6 mm 986 EARTHING CONNECTION 987 Connecting individual equipment to the earth strip or earth plate with following sizes of G.I. wire / G.I. wire rope including the supply of G.I. wire /G.I. wire rope, lugs, conductors, connecting to the G.I. strip or earth plate and necessary hardware for connection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 988 3/8 dia (10 mm) flexible rope. 989 5/8 dia (16 mm) flexible rope. 990 8 SWG GI Wire. 991 Supply and installation of 25 sq. mm (168/0.01772) copper flexibles of following length with copper lugs crimped on both sides for earthing of pipeline vessels, equipments (non electrical) as per std. 7- 51-0112, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 992 300 mm 993 500 mm 994 1500 mm 995 EARTH PLATES 996 Supply, installation and connection of GI earth plates as per std. 7-51-0103, complete with anchor bolts, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 997 GI earth plate as per std. 7-51-0103. 998 EARTHING CONNECTORS 999 Supply and installation of MS ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1000 Minimum 75mm to maximum 300 mm long 1001 Supply and installation of stainless steel ear of width 50 mm and thickness 5 mm for earthing of process vessels, steel structures, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1002 Minimum 75mm to maximum 300 mm long 1003 LIGHTNING RODS 1004 Supply and installation of GI lightning rod as per std. 7-51-0503 including supply of all hardware etc., including all labour and materials,as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1005 GI lightning rod as per std. 7-51-0503. 1006 LAYING OF COMMUNICATION / FIRE ALARM CABLES 1007 Horizontal and vertical laying/pulling through of communication/fire alarm cables of the following overall diameters in ready trays/trenches/conduits or supported on structures including supplying and fixing of GI saddle and saddle bars, stainless steel strip number tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1008 Cables of overall dia. above 35 mm. 1009 Cables of overall dia. upto 35 mm. 1010 Laying of HDPE ducts for laying of optical fiber cables between various substations, pulling through pipes or supported on structures including supplying and fixing of GI saddle and saddle bars, including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1011 HDPE duct with overall dia. Upto 60mm 1012 HDPE duct with overall dia. above 60mm 1013 Laying of optical fiber cables between various buildings in already laid HDPE conduits for plant communication and fire alarm data highway, feeder differential protection, etc., including supply of all hardware, splice connectors, accessories, pulling through pipes or supported on structures including supply and fixing of printed stainless steel/ non magnetic non corrosive metal tags, including transportation from store/yard to site at the place of installation, unpacking, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1014 Cables of overall dia. upto 40 mm. 1015 Cables of overall dia. above 40 mm. 1016 STRAIGHT THROUGH JOINTS COMMUNICATION / FIRE ALARM CABLES 1017 Making of straight through joints for polyethylene insulated armoured jelly filled/ non filled overall PVC jacketed, including supply of all necessary materials for the joint, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1018 For Non-Jelly filled cables of size .9 mm5 pair 1019 For Non-Jelly filled cables of size .9 mm20 pair 1020 For Non-Jelly filled cables of size .9 mm10 pair 1021 For Jelly filled cables of size .63 mm²20 pair 1022 For Non-Jelly filled cables of size 1.5 mm²2 pair 1023 Supply of straight through jointing kit for Mono mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1024 6 Fiber 1025 Supply of straight through jointing kit for Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1026 6 Fiber 1027 Making of straight through jointing kit for Mono/Multi mode, multitube/unitube, jelly filled, Optical fiber cable with non metallic armour with following number of fibers, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1028 6 Fiber 1029 END TERMINATIONS FOR COMMUNICATION/FIRE ALARM CABLES. 1030 Termination of following polyethylene insulated armoured jelly filled/ non filled cables including cutting, stripping of cable insulation, sealing of jacket including supply of termination kit, hardware, including all labour and materials, as per approved drawings, specification of this tender and directions of Engineer-in-Charge. 1031 For Non-Jelly filled cables of size .9 mm5 pair 1032 For Non-Jelly filled cables of size .9 mm2 pair 1033 For Non-Jelly filled cables of size .9 mm50 pair 1034 For Non-Jelly filled cables of size .63 mm20 pair 1035 For Non-Jelly filled cables of size 1.5 mm2 pair 1036 For Non-Jelly filled cables of size 1.5 mm²2 pair 1037 Supply ,Installation, testing and commissioning of Fiber Optic Patch panel (LIU) for following type & number of fiber for OFCs including all accessories for terminating, pigtails with Connectors, patch cords with connectors, Splicing sleeves and splice tray including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1038 For 6 fiber Mono mode cable with LC pigtails and LC patch cords 1039 For 6 fiber Mono mode cable with SC pigtails and LC patch cords 1040 For 6 fiber Mono mode cable with ST pigtails and LC patch cords 1041 For 6 fiber Mono mode cable with LC pigtails and SC patch cords 1042 For 6 fiber Mono mode cable with LC pigtails and ST patch cords 1043 For 6 fiber Mono mode cable with SC pigtails and SC patch cords 1044 For 6 fiber Mono mode cable with SC pigtails and ST patch cords 1045 For 6 fiber Mono mode cable with ST pigtails and SC patch cords 1046 For 6 fiber Mono mode cable with ST pigtails and ST patch cords 1047 Termination of optical fiber cables for various systems including supply of all hardware, splice connectors, accessories, including all labour and materials as per approved drawings specifications of this tender and directions of engineer-in-Charge 1048 6 Fiber 1049 SUPPLY OF COMMUNICATION / FIRE ALALRM CABLE / CONDUITS / DUCTS 1050 Supply of communication, fire alarm & control paired cables of following sizes as per EIL standard specification No.6-51-0052, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1051 Jelly filled cables of size .9 mm20 pair 1052 Jelly filled cables of size .9 mm10 pair 1053 Non-Jelly filled cables of size .9 mm5 pair 1054 Non-Jelly filled cables of size .9 mm2 pair 1055 Non-Jelly filled cables of size 1.5 mm2 pair 1056 Non-Jelly filled cables of size .9 mm50 pair 1057 Non-Jelly filled cables of size .63 mm2 pair 1058 Supply of Mono mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1059 6 Fiber multitube construction 1060 Supply of Multi mode, jelly filled, Optical fiber cable with non metallic armour with following number of cores & construction, as per EIL standard specifications, data sheet, specifications of this tender and directions of Engineer-in-Charge. 1061 6 Fiber multitube construction 1062 Supply of HDPE ducts for laying of optical fiber cables between various substations, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge 1063 HDPE duct with overall dia. Upto 60mm 1064 HDPE duct with overall dia. above 60mm 1065 CIVIL WORKS/M.S. CHEQUERED PLATE 1066 Making through and through cut outs in pockets of size 150 mm dia in the RCC floor/walls of trenches/buildings of thickness upto 200mm for facilitation cable entries using concrete cutting machines including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer -in-charge 1067 Excavation and backfilling of trenches for cables and earth strip etc. , for a maximum depth of 1.5 m, shoring, shuttering and dewatering (if necessary) including consolidation and disposal of surplus earth up to a distance of 30 m, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Excavated trench dimensions shall be measured). 1068 Excavation and backfilling of trenches in all types of soil including rock. 1069 Excavation and backfilling of trenches in all types of soil except rock. 1070 Supply and laying of 40 mm size gravel in one layer of 100/150 mm thick including dressing of soil surface and laying the aggregate in uniform layer and density, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge ( Aggregate will be measured in boxes of size 1.5 m x 1.5 m x 0.5 m which shall be taken as 1 cubic metre, the boxes are to be furnished by the contractor free of cost for measuring purposes). 1071 40 mm size gravel. 1072 Supply and spreading of approved fine river sand/stone dust in cable trenches, including all labour and materials, specifications of this tender and directions of Engineer-in-Charge. 1073 Fine river sand. 1074 Supply and spreading of approved FLY ASH BRICKS - TYPE-5 of 75 mm thickness in cable trenches for cable protection, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. (Actual area of laid brick surfaces shall be measured). 1075 Bricks. 1076 Supply, fabrication and installation of 6 mm thick M.S. chequered plate for covering floor cut- outs/cable trenches etc., including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-Charge. 1077 6 mm thick M.S. chequered plate. 1078 Making through and through cut outs in pockets of following shape and size in the RCC floor/ walls of trenches/ buildings of thickness above 200 mm and upto 400 mm for facilitating cable/ duct entries, using concrete cutting machines and making cut out good using plastering and painting including all material and labour as per approved drawings, specification of this tender and directions of Engineer-in-charge. 1079 Rectangular Cut Out of length 200 mmwidth 200 mm 1080 Circular Cut Out of diameter 150 mm 1081 LAN SYSTEMS 1082 Supply, installation, mounting, testing & commissioning of following Ethernet switches including performance warranty certification(for LAN) of 25 years through OEM, including all labour and materials, as per approved drawings, specifications of this tender and directions of Engineer-in-charge. 1083 Etherswitch Rack Type-I 1084 PAINTING & MARKING 1085 Letter painting and marking of all buses of switchboards, all incomers, bus couplers, outgoings with details of Tag No, feeder rating in KW/Amp, sending end source, in the front of the panels and bus bar, panel nos.etc. on the rear side of the panels for all switchboards, all other substation equipment viz.transformers, capacitors, neutral grounding resistors, VFD panels, other panels, etc for equipment housed in electrical substations including supply of all material such as stickers, enamel paints, stencil, etc including supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1086 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1087 Each alphabet/character upto 2 inch in height/length 1088 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1089 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1090 Letter painting of tag nos., applicable circuit nos. for identification with red/black/white paint for all outdoor equipment in safe and hazardous areas viz.light fittings, control gear boxes, lighting/power panels, welding receptacles, convenience receptacles, local control stations, fire alarm manual call points, fire alarm detectors, motors,field call stations, loud speakers, etc. including supply of enamel paint, all hardware as required,supply of all labour, materials as per the specification of this tender and directions of Engineer-in-Charge. 1091 Each alphabet/character above 2 inch and Upto 4 inch in height/length 1092 Each alphabet/character upto 2 inch in height/length 1093 Each alphabet/character above 4 inch and Upto 8 inch in height/length 1094 Each alphabet/character above 8 inch and Upto 12 inch in height/length 1095 INSTRUMENTATION 1096 PRESSURE GAUGES AND ACCESSORIES (Incl. supply of Impulse pipe/Tubing material) 1097 Installation of Line mounted or Remote mounted or Local Gauge Board mounted Pressure gauge/ Pressure gauge with Pulsation Dampener/ Syphon/ Overrange Protector (direct/ surface mounted/ diaphragm seal type) inclusive of mounting of instrument, supply of piping and tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specification, supply and erection of supports, mounting on support, (if support required), laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument, Gauge Board, Yoke, and Calibration. 1098 In Carbon Steel as per Standard 7-52-1103 1099 In Carbon Steel as per Standard 7-52-4079. 1100 DIFFERENTIAL PRESSURE GAUGES (Incl. supply of Impulse pipe/Tubing materials) 1101 Installation of Differential Pressure gauge with/ without pulsation dampner/Syphon/ overrange protector including one side capillary type)/ Diaphragm seal type Differential Pressure gauge, surface/ yoke mounted inclusive of mounting of instrument, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply and erection of supports, mounting on support, laying of capillary on supports, fabrication and installation of manifolds/ impulse lines with supports as per standards indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument and Calibration 1102 In Carbon Steel as per Standard 7-52-4077. 1103 In Carbon Steel as per Standard 7-52-4078. 1104 PRESS.INSTRUMENTS (Incl. supply of Impulse pipe/Tubing material) 1105 Installation of Pressure Transmitters/ Pressure Switches (with or without Pulsation Dampener, Overrange Protector)/ Diaphragm seal type Pressure Transmitters/ Diaphragm seal type Pressure Switches including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, supply of supports for capillary, supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1106 In Carbon Steel as per Standard 7-52-1101 1107 In Carbon Steel as per Standard 7-52-1159 1108 In Carbon Steel as per Standard 7-52-1188 1109 In Carbon Steel as per Standard 7-52-1102 1110 In Carbon Steel as per Standard 7-52-1163 1111 In Stainless Steel as per Standard 7-52-1159 1112 DIFFERENTIAL PRESSURE INSTRUMENTS (Incl. supply of Impulse pipe/Tubing materials) 1113 Installation of Differential Pressure Transmitters (including one side capillary type)/ Differential Pressure Switch(including one side capillary type)/ Diaphragm seal type DP Transmitters/ Diaphragm seal type DP Switch including mounting on Yoke/ Surface, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings as per specifications enclosed, ,supply and erection of supports for impulse lines wherever required, fabrication and installation of manifolds/ impulse lines with supports as per Standard indicated below, supply and fabricating of supports for capillary, laying of capillary on supports, painting, installation of flushing connection, hydraulic testing of impulse lines as per standard indicated below but exclusive of Supply of Instrument, all Electrical/ Pneumatic connections, Yoke and Calibration. 1114 In Carbon Steel as per Standard 7-52-1140 1115 In Carbon Steel as per Standard 7-52-1192 1116 DIFFERENTIAL PRESSURE (FLOW) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1117 Installation of Differential pressure(with or without integral manifold)/ Diaphragm Seal Type Differential Pressure flow instruments including Mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings as per specifications enclosed,supply of supports for impulse lines/ manifolds/ capillary, fabrication and Installation of manifolds/ impulse lines with supports as per Standard indicated below, laying of capillary on supports, hydraulic testing and painting of supports but exclusive of Supply of Instruments, all Electrical/ Pneumatic connections, Yoke and Calibration. 1118 In Carbon Steel as per Standard 7-52-3489. 1119 In Carbon Steel as per Standard 7-52-3490. 1120 In Carbon Steel as per Standard 7-52-3491. 1121 In Stainless Steel as per Standard 7-52-3490. 1122 ULTRASONIC FLOWMETER 1123 Installation of Transmitters/ Preamplifiers for ultrasonic flowmeters on yoke/ instrument (if required) including Straight length spool piece with pressure and temperature compensation loop including laying and termination of interconnection cable supports for cables as required, painting of supports but exclusive of supply of instrument, yoke and calibration. 1124 Installation of Transmitters/ Preamplifiers for Ultrasonic Flowmeters 1125 DIFFERENTIAL PRESSURE (LEVEL) TRANSMITTERS (Incl. supply of Impulse pipe/Tubing material) 1126 Installation of DP type/ Diaphragm Seal DP type Level Instrument including mounting on Yoke, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compressive fittings, as per specifications enclosed, supply of supports for impulse line/ capillary/ manifold, fabrication of manifolds and erection wherever required, laying of capillary on supports, fabrication and installation of impulse lines with support as per Standard indicated below, hydraulic testing and painting of supports but exclusive of Supply of Instrument,all Electrical/ Pneumatic connections, Yoke and Calibration. 1127 In Carbon Steel as per Standard 7-52-1523. 1128 In Carbon Steel as per Standard 7-52-1524. 1129 LEVEL GAUGES (Incl. supply of Impulse pipe/Tubing material) 1130 Installation of Level Gauges on Vessel/ Piping/ Standpipes with minor modification wherever required, supply of piping & tubing materials such as valves, fittings, pipes, tubes, compression fittings, as per specifications enclosed, fabrication of primary piping, fabrication and installation of drain valve/ vent valve assembly as per Standard indicated below, hydraulic testing of gauge, installation of illuminators/ non-frosting extension if required but exclusive of Supply of Gauges and Illuminators. 1131 In Carbon Steel as per Standard 7-52-1527 1132 SERVO TYPE TANK GAUGES 1133 Installation/ interconnection of Servo type Gauges with/ without Tank Farm Management (TFM) System components. Installation of Gauge, Isolation ball valve, Calibration chamber on flanged equipment nozzle, with or without still well, Junction boxes with barriers, power switch, all Electrical connections but exclusive of Supply of Instrument, still well and Calibration/ Setting of gauges. 1134 Servo Gauge Installation 1135 RADAR LEVEL INSTRUMENTS 1136 Installation of radar sensor and antenna, flanged type connection on equipment nozzle/ rail mounting with/without still well, but exclusive of supply of instruments. Installation of electronics units (total system for indication, transmission, marshalling etc. for one tank), including mounting on Yoke, supply of angle tray with supports, fabrication and erection of supports and laying of cable up to instrument/probe with clamps, termination of cables at both ends, but exclusive of supply of Instruments, supply of yokes and Calibration. 1137 Installation of Top Mounted Radar 1138 Installation of tank side indicator/electronic unit (total system for indication/ transmission/marshalling etc., as required for one tank) including mounting on yoke/support, fabrication and erection of supports, laying and termination of interconnecting cable up to instrument/ indicator with clamps, termination of cables at both ends, painting of supports but exclusive of supply of instruments, yoke, cables and calibration. 1139 Tank Side Indicator 1140 TEMPERATURE INSTRUMENTS 1141 Installation of Temperature Indicators/ Gauges (Filled system/ Bimetallic) RTD/ Thermocouple/ Temperature Switches/ Temperature transmitters with flanged thermowell inclusive of installation of machined/ built-up thermowells on the nozzle and installation of Instruments, Electrical/ Pneumatic connection but exclusive of Supply of Instruments/ Elements/ Thermowell, and Calibration. 1142 Temperature Indicator/ Gauges (Bimetallic Type) with thermowell on flanged wells 1143 TEMPERATURE TRANSMITTERS (REMOTE MOUNTED) 1144 Thermocouple/ RTD element with thermowell, along with Temperature Transmitter remote mounted. Installation of transmitter including mounting on yoke, fabrication and erection of supports with clamps and laying of extension/RTD cable upto thermocouple, termination of cables at both ends, painting of supports but exclusive of Supply of Instruments, Cable, Yoke and Calibration. 1145 Temperature transmitter and RTD. 1146 Temperature Transmitter and RTD with flanged well 1147 Multipoint temperature transmitter with Thermocouple / RTD 1148 MISCELLANEOUS ITEMS AND DEVICES 1149 Mounting of Miscellaneous instrument items as listed below on Yoke; fabrication and erection of Supports and including installation of instrument items,paintingofsupportsbutexclusiveofSupplyofInstrumentitems, Piping/ Tubing material / Calibration and supply and erection of Yoke support. 1150 ER probe assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1151 Corrosion coupon assembly with accessories like flange, valve etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1152 Weather proof Push Button Station/ Selector Switches. 1153 Corrosion Transmitters 1154 CALIBRATION/ TESTING 1155 Cleaning, adjusting stroke/ positioner, stroke speed checking of Control and On-off (Shutdown) valves. Providing equipments, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable and loop testing. Excludes flow calibration 1156 Control Valves 1157 Self Actuated Pressure reducing valves 1158 Cleaning, set pressure tests of Pressure Relief and Thermal Relief Valves. Providing equipment, necessary test jig, Instrument Air, Nitrogen Cylinders, test reports, all consumable. Excludes flow calibration. 1159 Sizes upto 3/4 x 1 threaded 1160 Inlet Sizes upto 2 flanged, rating 150# to 2500# 1161 Cleaning, calibration of the instrumentslisted below including removal of instrumentfromreinstalledlocationslikepanels,enclosures,racks,field etc.,andfixingthembackinrespectiveplaces,providingequipments, necessarytestjig,InstrumentAir,NitrogenCylinders,testreports,all consumable, exceptforspecialimportedtestequipments for electronic instruments to be supplied by owner if available. 1162 Pressure gauges 1163 Pressure transmitters 1164 Differential Pressure Gauges 1165 Differential Pressure Transmitters for Flow, Level and D.P. 1166 Temperature gauges 1167 Temperature Transmitters 1168 Tank Level Instrument (Radar type) 1169 Servo Type Tank Gauges 1170 Electronic Local Indicator 1171 Cleaning, checking and functional tests for flowmeters. Providing equipments, necessary test jig, Instrument Air, test reports, all consumable, except for special imported test equipments for electronic instruments to be supplied by owner if available. Excludes flow calibration. 1172 Ultrasonic flowmeters 1173 LOOP CHECKING 1174 Loop checking (excluding calibration/ testing) of the instruments listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1175 Pressure transmitters 1176 Differential Pressure Transmitters for Flow, Level and D.P. 1177 Temperature Transmitters 1178 Special Level Instruments/ Guided Wave / Ecclipse type Radar level instruments 1179 Tank Level Instruments (Radar type) 1180 Electronic Local Indicator 1181 Speed / Vibration Transmitter 1182 Push Button/Selector Switches/Lamps 1183 Control valve positioner 1184 Corrosion Transmitter 1185 Loop checking (excluding calibration/ testing) of the flowmeters listed below including verifying the functional performance of all elements comprising the loop, thereby ensuring proper interconnections and operation, with all other specifications inline with clause 4.13 of Standard specification for Erection tender 6-52-0060. 1186 Ultrasonic flowmeters 1187 SUPPLY ITEMS 1188 Supply of Instrument items as per specifications enclosed elsewhere in the Tender. 1189 24 Orifice plate as per Instrument data sheet no. B861-700-YF-DS-0001. 1190 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001. 1191 3/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0001/B861-851-YF-DS-0001. 1192 4/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-851-YF-DS-0001. 1193 Magnetic Level Gauge as per Instrument data sheet no. B861-701-YL-DS-2900. 1194 Breather valve as per Instrument data sheet no. B861-701-YB-DS-3200. 1195 Retractor Tool for ER probes system & Corrosion coupon system as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1196 Tubular ER Probe system (Tag No. 701-CP-1701) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1701), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1197 Tubular ER Probe system (Tag No. 701-CP-1801) with ER probe assembly,corrosion transmitter (Tag No. 701-CT-1801), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1198 Tubular ER Probe system (Tag No. 701-CP-1901) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-1901), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1199 Tubular ER Probe system (Tag No. 701-CP-2001) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2001), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1200 Tubular ER Probe system (Tag No. 701-CP-2101) with ER probe assembly, corrosion transmitter (Tag No. 701-CT-2101), 1 working and 1 spare ER probes for each ER probe locations as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1201 Corrosion coupon system (Tag No. 701-CC-1701) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3001 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1202 Corrosion coupon system(Tag No. 701-CC-1801) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon locationas per data sheet no. B861-701-YI-DS- 3002 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1203 Corrosion coupon system(Tag No. 701-CC-1901) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3003 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1204 Corrosion coupon system(Tag No. 701-CC-2001) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3004 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1205 Corrosion coupon system(Tag No. 701-CC-2101) with Corrosion Coupon Holder Assembly, 25 nos. of coupons for each corrosion coupon location as per data sheet no. B861-701-YI-DS- 3005 &as per Job specification for corrosion monitoring system document no.B861-000-06-42-CMS-0001. 1206 24 V DC loop powered spare corrosion Transmitter. 1207 Type: Non-contact type Radar Level Instrument (Tag No. 700-LT-1601)as per data sheet no.B861-700-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1208 Type: Non-contact type Radar Level Instrument (Tag no. 700-LT-1602)as per data sheet no.B861-700-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply,Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1209 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2201) as per data sheet no.B861-701-YL-DS-2000 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316 , Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1210 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2203) as per data sheet no.B861-701-YL-DS-2001 , Smart Transmitter with integral display, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1211 Type: Non-contact type Radar Level Instrument (Tag No. 701-LT-2204) as per data sheet no.B861-701-YL-DS-2002 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 6 Flanged connection / Top mounted , Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1212 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5501) as per data sheet no.B861-851-YL-DS-2000 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART / 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1213 Type: Non-contact type Radar Level Instrument (Tag No. 851-LT-5502) as per data sheet no.B861-851-YL-DS-2001 , Smart Transmitter with integral display & local indicator, Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply.Gauge Head: 8 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART /1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1214 Type: Servo Level Instrument (TagNo. 701-LT-2202) as per data sheet no.B861-701-YL-DS-2003 , Smart Transmitter with integral display , Power supply: 24 VDC Loop powered or separate 240V AC UPS Supply, Gauge Head: 6 Flanged connection / Top mounted, Flange Material: SS316, Accuracy: +/- 3mm, Output: 4-20 mA HART/ 1/2 cable entry connectionfor signal & 3/4 cable entry connection for power (if applicable). 1215 Signal cableXLPE insulatedFRLS 2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7006. 1216 2/300# Orifice plate & flange assembly as per Instrument data sheet no. B861-700-YF-DS-0002. 1217 Signal cableFR2 QUAD X1.5 mm2 as per data sheet no.B861-000-YS-DS-7009. 1218 Industrial grade 4 1/2 digit digital Multimeter including accessories like battery, connecting pin, carry bag. 1219 Industrial grade digital mA loop calibrator including accessories like battery, connecting pin, carry bag. 1220 Industrial grade Multifunction calibrator with low , high pressure pump including accessories like charger, connecting pin, carry bag. 1221 Universal hand-held HART communicators with accessories including charger, connecting pin, carry bag. 1222 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3150 & B861-851-YI-DS-3150. 1223 Differential Pressure (Flow) Transmitter-HART as per data sheet no. B861-700-YI-DS-3151. 1224 Differential Pressure Transmitter-HART as per data sheet no. B861-700-YI-DS-3200. 1225 Differential Pressure (Level) Transmitter-HART as per data sheet no. B861-701-YI-DS-3050. 1226 Pressure Transmitter-HART as per data sheet no. B861-700-YP-DS-3001,B861-700-YP-DS-3002, B861-700-YP-DS-3003 & B861-701-YP-DS-3001. 1227 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3002 & B861-851-YP-DS-3002. 1228 Pressure Transmitter-HART as per data sheet no. B861-701-YP-DS-3003 & B861-851-YP-DS-3001. 1229 Multipoint Temperature Elements - RTD with thermowell as per data sheet no. B861-701-YT-DS-4050. 1230 Temperature Elements - RTD with thermowell as per data sheet no. B861-700-YT-DS-4101, B861-701-YT-DS-4002, B861-851-YT-DS-4001. 1231 Temperature Transmitter-HART as per data sheet no. B861-700-YI-DS-3100, B861-701-YI-DS-3100, B861-701-YI-DS-3101, B861-701-YI-DS-3102 & B861-851-YI-DS-3100. 1232 Temperature Elements - RTD as per data sheet no. B861-701-YT-DS-4001. 1233 Signal cableFR 1PX1.5 mm2 as per data sheet no.B861-000-YS-DS-7008. 1234 Pressure Gauges as per data sheet no. B861-851-YP-DS-1100 & B861-700-YP-DS-1100, B861-701-YP-DS-1100. 1235 Temperature Gauges with thermowell as per data sheet no. B861-851-YT-DS-4100, B861-700-YT-DS-4105, B861-701-YT-DS-4100. 1236 Pressure Gauges as per data sheet no. B861-700-YP-DS-1101, B861-701-YP-DS-1101. 1237 Differential Pressure Gauges as per data sheet no. B861-700-YP-DS-1102, B861-701-YP-DS-1102. 1238 Temperature Gauges with thermowell as per data sheet no. B861-700-YT-DS-4104, B861-701-YT-DS-4101. 1239 Signal cableXLPE insulatedFRLS 12PX1.5 mm2 1240 Signal cableXLPE insulatedFRLS 1PX1.5 mm2 1241 Supply of Junction boxes of various types and specifications 1242 Junction Box, Weatherproof type for 12 Pair Cable 1243 Junction Box, Weatherproof type for 3 Way 1244 Supply of Cable glands ofvarioustypes and specifications 1245 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1/2 NPTM 1246 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 1 1/2 NPTM 1247 Weatherproof double compression type Cable gland, SS 304 material with PVC shroud, 3/4 NPTM 1248 Supply of plugs for cable entries of varioustypes and specifications 1249 Plug ,weatherproof type, SS 304 material, 1/2 NPTM 1250 Plug ,weatherproof type, SS 304 material, 1 1/2 NPTM 1251 Plug ,weatherproof type, SS 304 material, 3/4 NPTM 1252 Supply of compression tube fittings in Stainless Steel of various types and specifications 1253 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/2 OD 153 Bar 1254 Male Connector: Material: SS-316 : Size: 1/4 NPTM X 1/4 OD 153 Bar 1255 Male Connector: Material: SS-316 : Size: 1/2 NPTM X 1/4 OD 153 Bar 1256 SS 316 Ball Valve 1/2 TH 41 Bar. 1257 Tube Union: Material: SS-316 ; Size: 1/2 OD x 1/2 OD 153 Bar 1258 Tube Cap; Material: SS-316 ; Size : 1/2 OD 153 Bar 1259 6 Way Air Manifold SS316 1260 Supply of instrument tubes of different types and specifications 1261 SS316L tube 1/2 OD 153 Bar 1262 SS316L tube 1/4 OD 153 Bar 1263 Supply of pipe and pipe fittings 1264 SS316 Pipe 1 PL End, SCH. 40S 1265 10% of impulse piping / tubing material subject to minimum 1 number (1 meter for pipe / tube), whichever is higher, of each type, size, rating & material wise (such as valves, fittings, pipes, tubes, compression fittings as listed in the list of items of installation standard no. 7-52-3489, 7-52-3490, 7-52-3491, 7-52-1527, 7-52-1523, 7-52-1524, 7-52-4077, 7-52-4078, 7-52-1192, 7-52-1140, 7-52-1103, 7-52-4079 , 7-52-1101, 7-52-1102, 7-52-1159, 7-52-1188 & 7-52-1163) in the overall SOR quantity as per specification as a Mandatory spare. 1266 SS316 Nipple 1/2 TH x TH, SCH. 80S 1267 SS316 Nipple 1 TH x PL, SCH. 40S 1268 SS316 Nipple 1 PL x PL, SCH. 40S 1269 SS316 Equal Tee 1 SW, 3000# 1270 SS316 Elbow 1” SW, 3000# 1271 SS316 Cap 1/2” TH, 3000# 1272 SS316 Cap 1” TH, 3000# 1273 SS316 Coupling full 1” SW, 3000# 1274 SS316 Globe Valve 1 SW, body rating: 800#, end rating: 3000# 1275 JUNCTION BOX INSTALLATION 1276 Installation of weatherproof junction boxes including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 12Px0.5/1.0/1.5/2.5 mm² Signal/Alarm/ Control. 1277 Installation of weatherproof three way junction boxes for Power including supply, fabrication and installation of supports, installation of junction boxes, supply of 14 SWG Copper wire (max. length 10 m per Junction Box), laying and connection, screwing plugs for unused entries and painting but exclusive of supply of junction boxes and glands/ fittings for cable size 2C x 2.5 mm² 1278 LAYING OF CABLES 1279 Laying of instrumentation cables for signal, alarm, shutdown, control and signal cable on ducts, main trays, perforated trays, angle trays, trenches (including opening of cable duct covers if requiredthrough IRCs {Instrument Road Crossings}) including clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire, providing and fixing identifying tags and megger testing but exclusive of supply of cables and erection of ducts, main tray, perforated tray/ angle trays and preparation of cable trench. 1280 Signal / Alarm / Control Cables of cable sizes 1P x 1.5 / 2.5 mm² 1281 Signal/ Alarm/ Control Cables of cable sizes 24C /12P x 1.5/ 2.5mm² 1282 Laying of power cables on ducts, main trays, perforated trays, angle trays, trenches (including through IRCs) including opening of cable duct covers if required clamping, glanding the cables, termination at both ends including shield/ drain/ communication wire providing and fixing of identifying tags and megger testing but exclusive of supply of multi cables and erection of ducts, main tray, perforated tray/ angle tray and preparation of cable trench 1283 For cable size 2C x 2.5 mm² 1284 EARTHING 1285 Supply, laying and termination of both ends of earthing cables from earth grid pit to the DCS/ Local panels/ Barrier earth bus bars in trays/ conduits/ trenches as required. 1286 At both ends of earth grid/ Instruments of copper wire (12 AWG) in trays and conduits as required excluding earth-pit preparation and electrode installation. 1287 PIPING / TUBING / FABRICATION WORK 1288 Fabrication and erection of SS Air lines and fittings including supply/ fabrication/ erection of supports, installation of distribution, pneumatic testing and painting of supports but exclusive of supply of pipe and fittings as per standard 1289 For size 1 1290 Laying of Bare/ PVC covered copper tubes/ SS tubes on perforated trays including clamping, termination at both ends, providing identifying tags at both ends and Air testing, but exclusive of supply of copper/SS tubes, fitting and erection of perforated tray/ angle tray 1291 1/2 / 12 mm O.D . (for SS tubes) 1292 Erection of SS Air distribution manifold and fittingsincludingsupply/ fabrication/ erection of supports, pneumatic testing andpaintingofsupportsbutexclusiveofsupplyofSSAir distribution manifold and fittings 1293 Installation of 6-way Air Manifold (1/2) as per Standard 7-52-1905 1294 Tubing Hook-up of Control valves/ Pneumatic Transmitters etc. with air filter regulator / positioner / solenoid valves / Current to Pneumatic converters etc. as per Standards 1295 as per standard 7-52-3982. 1296 RADIOGRAPHY - CARBON STEEL WELD JOINTS 1297 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Gauges 1298 In Carbon Steel as per Standard 7-52-1103. 1299 In Carbon Steel as per Standard 7-52-4079. 1300 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differrential Pressure Gauge 1301 In Carbon Steel as per standard 7-52-4077. 1302 In Carbon Steel as per standard 7-52-4078. 1303 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1304 In Carbon Steel as per Standard 7-52-1101. 1305 In Carbon Steel as per Standard 7-52-1159. 1306 In Carbon Steel as per Standard 7-52-1188. 1307 In Carbon Steel as per Standard 7-52-1102. 1308 In Carbon Steel as per Standard 7-52-1163. 1309 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure Instruments 1310 In Carbon Steel as per Standard 7-52-1140. 1311 In Carbon Steel as per Standard 7-52-1192. 1312 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1313 In Carbon Steel as per Standard 7-52-3489. 1314 In Carbon Steel as per Standard 7-52-3490. 1315 In Carbon Steel as per Standard 7-52-3491. 1316 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Level) Instruments 1317 In Carbon Steel as per Standard 7-52-1523. 1318 In Carbon Steel as per Standard7-52-1524. 1319 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Magnetic Level Gauges 1320 In Carbon Steel as per Standard 7-52-1527. 1321 RADIOGRAPHY - CS SPECIAL, ALLOY STEEL, SS 1322 Radiography conforming to the requirements of the Piping Class for all weld joints in Piping of Instrument air supply distribution, In Stainless Steel as per Standard 7-52-1905. 1323 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Pressure Instruments installations 1324 In Stainless Steel as per Standard 7-52-1159. 1325 Radiography conforming to the requirements of the Piping Class for all weld joints in impulse piping of Differential Pressure (Flow) Instruments 1326 In Stainless Steel as per Standard 7-52-3490. 1327 Fire protection of instrument cable duct/trays 1328 Supply and erection of fire protection material for instrument cable ducts as per specification enclosed elsewhere with tender 1329 Run of Duct 600mm(W) X 300mm(H) 1330 Supply and erection of fire protection of cable trays as per specification enclosed elsewhere with tender 1331 Run of Tray 100mm (W) X 30mm (H) 1332 Run of Tray 60 mm (W) X 20mm (H) 1333 Run of Tray 150 mm (W) X 75 mm (H) 1334 Run of Tray 300 mm (W) X 75 mm (H) 1335 STRUCTURAL 1336 Supply, Fabrication and erection of Galvanised Iron duct and its supports as per standard. Duct configurations include Duct Equal Tee, Duct Expander Tee, Duct Reducer Tee, Duct Offset Bend, Duct with Reducer, Vertical Plane Tee, Vertical Plane Elbow, Duct Bridge (jumpover), Sleeves. 1337 Run of Duct 1000mm (W) X 400mm (H) 1338 Run of Duct 600mm (W) X 300mm (H) 1339 Run of Duct 800mm (W) X 300mm (H) 1340 Supply and erection of prefabricated FRP perforated trays with covers as per specifications enclosed elsewhere in tenderdocument and its support including tees, bends and elbows 1341 tray of 60 mm (W) X 20 mm (H) 1342 tray of 150 mm (W) X 75 mm (H) 1343 tray of 300 mm (W) X 75 mm (H) 1344 tray of 100 mm (W) X 30 mm (H) 1345 CANOPY FOR INSTRUMENTS AND JUNCTION BOXES 1346 Supply of Prefabricated FRP canopies along with mounting accessories for local instruments, Transmitters, Junction Box etc. for mounting on the stanchion and alignment as per standard 7-52-0105 1347 FRP Canopy (All sides closed) - Field Instruments 1348 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1349 FRP Canopy For Junction Box - Front Side Open 1350 FRP Canopy (All Side Closed) - Guided Wave , Mass Flow Meter 1351 FRP Canopy for RTD / Thermocouple 1352 Erection of Prefabricated FRP canopies for local instruments, Transmitters, Junction Box etc. on the stanchion and alignmentas per standard 7-52-0105 1353 FRP Canopy (All sides closed) - Field Instruments 1354 FRP Canopy (All Side Closed) - Temperature Transmitter and Loop Powered Indicator 1355 FRP Canopy For Junction Box - Front Side Open 1356 FRP Canopy for RTD / Thermocouple 1357 FRP Canopy (All Side Closed) - Radar Level Instruments 1358 GENERAL SITE WORK 1359 Supply of Yoke supports for transmitters/ preamplifiers (wherever applicable) including supply, fabrication and erection of instrument yoke of all types and painting of yoke supports but exclusive of mounting of Instrument on supports. 1360 2 Yoke supports as per standard 7-52-0101 1361 Erection of 2 Yoke supports/ stanchions for Instruments but excluding supply and fabrication of Yoke support. 1362 Erection of2 Yoke supports for instruments excluding supply of Yoke 1363 Supply, fabrication and installation of structural supports with MS channel/angle/plates etc. for supports ofmiscellaneous instruments/cabinets/panels including cutting, welding , bolting, rivetting, groutingincluding supply and installation of installation hardware like anchor bolts/nuts etc., painting of supports including supply of paints as per specification, including all labours and materials and completion of jobs in all aspects as per drawings/directions of Engineer-in-Chargenor paid). 1364 Structural steel ISMC 100 1365 Identification of instrument items wherever required including supply of approved colour of paint/ paints (Fluorescent), painting of tag number (approx 25-50 mm high) on instrument item like transmitter, switches, level gauges, control valves etc. as specified by Engineer-in-Charge. 1366 Identification of instrument items 1367 Supply, Fabrication & Installation of Concrete Pedestal (RCC) for supporting JB/Yoke but exclusive of supply of JB/Yoke as per specifications/drawing attached 1368 Size 500 mm x 500 mm x 600 mm 1369 SITE ACTIVITIES BY MECHANICAL CONTRACTOR 1370 Supply & wrapping of single layer PIR Insulation (Cold conservation type insulation ) with thickness of 50mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1371 Supply & wrapping of single layer PIR Insulation (Surface condensation type insulation ) with thickness of 25mm for 1/2 impulse lineconsist of insulation blocks fixed with adhesives, joint sealants, protected from moisture/ water ingress by vapour barrier, vapour stop and covered with a weather protection jacket after cleaning the impulse lines of dust, rust, grease in line withJob specification for Insulation of piping & equipment ( B861-000-06-43-IL-S001 ) attached in the tender. The wrapping of the insulation around impulse line shall cover it completely without leaving any gap. Scope of supply & wrapping by Contractor includes all material, tools, tackles & labour etc. to complete the work in all respects. 1372 Transportation of all types of valves (Including Control Valves, Special Control Valves, Motor Operated Valves, PRDS, Control valves, On-Off/Shutdown valves, Self actuating valves) from Owners storage points to contractors stores/worksite and installation of valvesfor all rating including assembly of valves accessories like air bottles etc, if any, fixing of gaskets bolts/nuts wherever required and performing Positive Material Identification(PMI) using alloy analysers as per specification, drawings and directions of Engineer-in-Charge. 1373 Inlet Valve size - 12 , Rating - 300# 1374 Inlet Valve size - 1 , Rating - 300# 1375 Inlet Valve size - 1 1/2 , Rating - 300# 1376 Inlet Valve size - 3 , Rating - 300# 1377 Transportation of all types of Safety Valves, Pilot Operated Safety Valves from owners storage point to contractors store/worksite and installation of valves for all ratings including assembly of valves, accessories if any, at alllocations and fixing of gaskets, bolts/nuts wherever required as per drawings, specifications and as per the directions of engineer-in-charge. 1378 Inlet size - 1 , Rating - 150# 1379 Inlet size - 2 , Rating - 150# 1380 Inlet size - 4 , Rating - 150# 1381 Inlet size - 3/4 , Rating - NPT 1382 Impulse line painting (uninsulated) as per painting specification for project 1383 Instrumentation impulse line of size 1/2 for temp. (-)14 to 80 degC 1384 Impulse line painting (insulated) as per EIL painting specification for project. 1385 Impulse line size of 1/2 with material Carbon Steel for temp. (-)45 to 125 degC 1386 ENVIRONMENT 1387 Condensate Water Treatment Plant 1388 CONDENSATE WATER TREATMENT PLANT, WITH COMPLETE ACCESSORIES & AUXILLARIES (As per Document no. B861-000-17-42-SS-1001): The scope of work shall include design, engineering, procurement, fabrication, supply, transport, handling, storage at site, erection, civil, electrical, piping, painting, mechanical and instrumentation works, testing, pre-commissioning, commissioning, trial run and guarantee of condensate water treatment system and handing over of the same to the Owner. 1389 EQUIPMENT - PACKAGE 1390 Design, engineering, procurement of raw materials and bought out components, manufacture, assembly, inspection, testing, painting (both primer and finish coat) , erection, testing &commissioning of following Basket Strainers along with associated equipment/items complete in all respect for efficient & satisfactory operation as per enclosed Scope of Work (Doc no. B861-000-80-42-SOW-3001) & Process data sheets. 1391 BASKET STRAINERS, Tag Nos. 701-STR-1701/1702 1392 BASKET STRAINERS, Tag Nos. 701-STR-1801/1802 1393 BASKET STRAINERS, Tag Nos. 701-STR-1901/1902 1394 BASKET STRAINERS, Tag Nos. 701-STR-2001/2002 1395 BASKET STRAINERS, Tag Nos. 701-STR-2101/2102 1396 Supply and Installation of Wall mounted Split Air Conditioners for Store Officer cabin : Supply of single phase inverter controlled Split Air Conditioner with compatible stabilizer (copper winding) complete with all accessories and fittings, including supply of first fill of refrigerants (non-CFC and eco-friendly), remote control, transportation from vendors works to site, unloading at site, handling, transportation to contractors store and from contractors store to work site, storage at site, assembly at site, installation and other field works including civil-structural works complete in all respect, testing, painting, insulation, commissioning, handing over to client. Split unit shall have wall mounted indoor unit and outside located air cooled condenser (outdoor unit) with insulated refrigerant piping (considering approx 10 m length between indoor and outdoor unit), controls and accessories, electrical and civil works(e.g. civil work related to concealing of refrigerant piping, drain piping to the nearest drain, cabling (considering approx 10 m length between indoor and outdoor unit) of AC units) as required including the structural steel framework, pedestal/bracket to mount the indoor and outdoor units, supports & clamps for refrigerant piping/cables, stabilizer, hold down nuts & bolts, spares for commissioning and start up etc. as per the enclosed Job Specification and other documents referred therein and instruction of engineer-in-charge for each equipment including accessories. 1397 Inverter Type Split Air Conditioner of capacity 1.5 TR having star rating 5 (BEE 5 star rating or equivalent) 1398 EOT CRANE (SAFE AREA APPLICATION) FOR MATERIAL STORE/ WORKSHOP BUILDING :Radio Remote Control(1 Working+ 1 Stand by) Operated-Design, engineering, manufacture, procurement of raw materials and bought out components, supply, fabrication, assembly, shop painting (primer + finish coat), inspection, testing (at manufacturers shop), packing and supply of double girder type EOT Crane including supply of all commissioning spares, special tools and tackles as applicable, mandatory spares, first fill of lubricant, consumables,erection material & documentation, transportation from Vendors works to designated storage site, handling, loading, unloading and storage, complete site works including transportation from storage site to work site, storage & handling at work site, assembly at site, erection installation, testing, touch-up painting, pre commissioning, commissioning, performance guarantee test run including arrangement of test loads, completing thework in all respects and handling over to Client, as per drawing, specifications, scope of work and instructions of engineer in charge and other attachment included in Tender for following EOT Crane.NOTE 1: Span or/and travel length of crane may undergo minor changes of ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE 2: Height of lift may undergo minor changes by ±0.5 meter during detailed engineering, for which no price & time implication shall be entertained.NOTE-3: Contractor shall arrange/bring adequate certified test loads during testing at EOT crane location. To and Fro transportation of test loads with cage (including loading, handling, unloading etc.), including taking back of test load after successful performance test from worksite and supply of manpower shall be in scope of Contractor). 1399 1 No. Double Girder E.O.T Crane with Main hook SWL (Safe Working Load) 15 MT , Auxillary hook SWL 3 MT , Span -12.7 m, Long Travel - 30 m , Height of lift - 8 m, M5 duty along with rails, fixtures and other accessories.(Refer Scope of Work , Job Specification & Electrical specifications ) enclosed elsewhere with this tender document). 1400 UNIT RATES FOR E.O.T CRANE FOR ADDITION/DELETION PURPOSE 1401 Unit Rate (ADDITION / DELETION) for ±0.5m in HEIGHT OF LIFT (over & above 0.5 m from specified data) 1402 Unit Rate (ADDITION / DELETION) for ±0.5m in SPAN (over & above 0.5 m from specified data). 1403 Unit Rate (ADDITION / DELETION) for ±0.5m in LONG TRAVEL (over & above 0.5 m from specified data) including rail fixtures. 1404 EQUIPMENT - ROTATING 1405 Handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1406 Pump Packages (all types) with drivers, auxiliaries and accessories. 1407 All Types of Pumps (Electric Motor Driven) along with driver, auxiliaries and accessories (Single Skid). 1408 Chemical Dosing Packages 1409 Skid mounted chemical dosing packages along with all auxiliaries and accessories. 1410 Procurement of Rotating Equipment Packages by Contractor.Engineering and Procurement of Rotating Equipment, handling and transportation of Rotating Equipment & miscellaneous items of equipment package from Owners storage points to work site / contractors stores, assembly of sub-assemblies, field assembly (as applicable) placing the equipment on foundations,(including some amount of cutting, welding & field joints wherever required), levelling, aligning, fixation of foundation bolts, providing (including supply) packing / shim plates (as applicable), including chipping & dressing of foundations, grouting (including supply and application of grout material, equipment base frame filling as per vendor recommendation with specified grout), cleaning and flushing, draining and drying, purging of lines, and providing manpower and tools / equipmentforNDT, testing, carrying out trial and start-up runs and testing under supervision of manufactures / customer personnel, rectifying defects (if any), insulation (as applicable),precommissioning and commissioning (as applicable) and completing the work in all respects as per drawings, job specifications / scope of work and instructions of Engineer-in-charge for each equipment including drivers and accessories, as listed below.NOTE: Scope also includes erection, fabrication, insulation (as applicable), welding & field joints wherever required, installation & NDT of vendor supplied prefabricated spools / commercial length between various skids of an equipment package (payable at the rate provided against piping SOR items). 1411 Diesel Engine based Electric Generator Set Packages with auxiliaries and accessories. 1412 Equipment Tag No. 701-DG-001 as per Document No. B861-000-80-42-SOW-3001 1413 EQUIPMENT - STATIC 1414 STORAGE TANKS 1415 PLATE WORK 1416 Plate work for Fixed Roof Tanks (Cone and Dome roof tanks) and covered Floating Roof tanks except Floating Roof:Procurement of all plates as per specifications, transportation to work site, fabrication and erection of shell, bottom (Sketch plates and annular plates including backing strips), cone roof, Dome roof, compression ring/knuckle plate, plate fabricated wind girders, wind girder opening, bearing plates for pipe supports, datum plates, shell manhole- necks, bolting and cover flanges for shell-man-holes, reinforcement pads for shell manholes, nozzle reinforcing pads, roof manhole-necks, bolting and cover flanges for roof manholes, reinforcing pads for Roof manholes, clean-out door assembly (including davit assembly), gusset- support for wind girders, Sump for drain nozzle, pads for all appurtenances and attachments, fabrication and installation of all items as per drawing, conducting tests such as vacuum test, MP/DP test, pneumatic test, oil penetrant examination, Grouting work (including the supply of grouting material, as required for the tanks installed on ring wall foundation) underneath the Annular/ bottom plateas per the specifications attached, tank hydrotest, etc. for shell, bottom and roof as specified, radiography including supply of films, all heat treatment specified in drawings/ specifications/ codes, preparation of drawings as per specifications, standards and relevant codes and getting the same reviewed by Owner/EIL, providing all temporary structures, clamps, wedges, including arrangement of all materials, consumables, labour, equipment, machinery, tools, tackles etc. to complete the work in all respects as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge.All bolting, gaskets wherever required as per scope of supply and scope of work shall be supplied and installed by Contractor. Spares 10% bolting (min. 2 nos.) and 200% spare gaskets shall be included in Contractors scope. Any other (Commissioning etc.) spares as mentioned in tender specifications shall be also be included in Contractors scope.Quoted price shall be inclusive of supply of all bolts, nuts, gaskets including spares. 1417 IS 2062 Gr. E250 (A, BR, B0, C) 1418 SA 516 Gr. 60/ 70 1419 STRUCTURAL/PIPES 1420 STRUCTURAL/ PLATE WORK :Supply, fabrication, erection, inspection and testing of steel structure for cone roof/ dome roof supporting structure including curb angle, spiral stairway, cage ladder, handrail, top and intermediate platform, grating for stairway steps and platform, rolling ladder including track for floating roof, anchor chairs,name plates, earthing connections, ladder rungs for ladders in covered roof tanks, wind girder fabricated from rolled section, wind girder bracings/ support, external structural supports, supports for shell extension for foam nozzles in case of floating roof tanks, stiffeners for shell extension plate of stairway, ventilation slots and over flow slots for covered floating roof tank including SS wire mesh, preparation of drawings, getting the same reviewed/ approved by owner/ EIL, arrangement of all materials, consumables, labour, equipment/ machinery, tools and tackles required to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1421 Roof structure as per Standard/Drg. 1422 SA 36 1423 IS 2062 1424 SA 516 Gr.60/70 1425 STILL WELLS/ DIP PIPES :Supply, fabrication, erection, inspection and testing ofstill well for gauge hatch, still well for level transmitter/ level switches, still well for temperature element including flanges on all still wells, dip pipes (process / instrumentation), pipe fittings, drilling of holes in still well/ dip pipes, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1426 SA 333 GR6 1427 SA 106 Gr. B 1428 STRUCTURAL PIPES (CS GALVANISED):Supply, fabrication, erection, inspection and testing of pipe specification for pipe handrails (CS and galvanised), arrangement of all materials, consumables, labour to complete the work as per drawings, specifications, standards, codes, scope of work, scope of supply and instructions of Engineer- in-Charge. All materials to be supplied by Contractor. 1429 PIPES(CS GALVANIZED) 1430 APPURTENANCES 1431 Supply, fabrication, installation, welding, radiography, heat treatment, inspection and testing as required for the following nozzles (reinforcing pads covered under plate work) pipe, nozzle flanges and blind / companion/matching flanges (including davit/ hinge assembly for Man way) wherever shown on drawings and standards along with gaskets and boltings including supply of mandatory spares, conducting air pressure test for reinforcing pads, preparation of drawings, getting the same reviewed by Owner/EIL, arrangement of all materials, consumables, labour to complete the work as per drawings, specifications , standards, codes, scope of work, scope of supply and instructions of Engineer-in- Charge. All internal bolting shall be SS 304 as a minimum and contractor shall include the same in his scope of supply and shall be included in nozzleassembly quoted price. Spare gaskets ( 2 nos.) and 10% spare bolting (minimum 2 nos.) shall be included in Contractors scope of supply and shall be included in nozzle assembly quoted price. 1432 Roof Nozzle 150 Class WNRF Type 1.5 InchSize SA 350 LF2 Material 1433 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1434 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 105 Material 1435 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 105 Material 1436 Shell Nozzle 150 Class WNRF Type 4 InchSize SA 105 Material 1437 Shell Nozzle 150 Class WNRF Type 6 InchSize SA 105 Material 1438 Roof Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1439 Roof Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1440 Roof Nozzle 300 Class WNRF Type 3 InchSize SA 350 LF2 Material 1441 Roof Nozzle 150 Class WNRF Type 6 InchSize SA 350 LF2 Material 1442 Roof Nozzle 150 Class WNRF Type 8 InchSize SA 350 LF2 Material 1443 Shell Nozzle 150 Class WNRF Type 2 InchSize SA 350 LF2 Material 1444 Shell Nozzle 150 Class WNRF Type 3 InchSize SA 350 LF2 Material 1445 GOOSE NECK VENT WITH WIRE MESH:supply of materials,fabrication, installation,welding, radiography, heat treatment, inspection and testing as required for the (reinforcement pads covered under Plate work) goose neck vent with wire mesh (SS 304 as minimum) for the following vent materials. 1446 Size 2 InchMaterial SA 106 Gr. B 1447 INSTRUMENTS 1448 Transportation of following instruments from Owner/Storage yard/stores and installation of the same in position as per instructions of Engineer-in-Charge/Supplier. (Contractor shall take care so that no damage occurs while handling these instruments). 1449 Pressure Transmitter Instrument 1450 Level Transmitter Instrument 1451 Breather Valve Instrument 1452 Emergency Vent Instrument 1453 Temperature Gauge Instrument 1454 CALIBRATIONCarrying out calibration of tanks including supply of strapping tapes, scaffolding wherever required, arranging the visit of competent authority, all accessories, labour, preparation and submission of calibration charts duly approved by Competent authority etc. and complete the work in all respect as per Codes, specifications, standards and instructions of Engineer-in-Charge 1455 Diameter (Meters) : upto 10 Height (Meters) : upto10 1456 Diameter (Meters) : > 10 to 25 Height (Meters) : > 10 1457 DESIGN, SUPPLY & INSTALLATION OF EMERGENCY VENT (Lumpsum)Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed M/s EIL specification and installation of Emergency Vent etc. to the satisfaction of the Engineer- in Charge. 1458 DESIGN, SUPPLY & INSTALLATION OF BREATHER VALVE (Lumpsum):Design, engineering, manufacture, procurement of materials and bought out components, assembly at shop, inspection, testing at manufacturers works, packing, delivery, documentation as per the enclosed EIL specification and installation of breather valves etc. to the satisfaction of the Engineer-in-charge. 1459 Gauge Hatch with Cover:Supply & installation of Gauge Hatch with Cover for the tankages mentioned in the data sheets/ drawings/ specifications as per the Specifications & Standards attached with the tender. Arrangement of machinery, tools & tackles, labour etc. to accomplish the installation of the same shall also be in the scope of Contractor. The following Gauge Hatch with cover are required. 1460 Material: CS 1461 PAINTING OF TANKS 1462 PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS 1463 ExternalSurfaces (except underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onallexternalsurfacesoftanksincluding insulatedtanks i.e.externalshell,windgirders,appurtenances,rooftops including top sideoffloatingroofofopentanksaswellascovered floatingrooftanks, external roof supporting structure,associatedstructuralsteelworks,ladders,walkways, platforms,handrails,spiralstairway,rollingladderandtrack, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets, stencillingtankno., capacity, name of storedproduct,paintingEmblem aspertheattachedsample,includingsupply of metallicandnon-metallic materials,primerandpaintofapprovedquality,providingscaffolding, labour,equipment,consumables,etc.tocompletetheworkinall respect asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1464 Design Temperature Range: (-) 14 °CTo 80 °CPrimer: 1coat of F-9 @ 65-75μ DFT/coat + 1coat of P-6 @ 40μ DFT/ coat Finish Paint: 2 coats of F-6B @ 100μ DFT /coat + 1 coat of F-2 @ 40μ DFT/ coat Remarks: Total DFT in Microns (minimum) = 345-355 1465 ExternalSurfaces (underside of bottom plate): Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint onunderside of bottom plate (soil side) asper painting system defined below and otherrequirementsasspecifiedinrespectiveEngg.datasheets includingsupplyofmetallicandnon-metallic materials,primerandpaintofapprovedquality,labour,equipment,consumables,etc.tocompletetheworkinall respect,asperapplicable standard specifications,standardsattached elsewhere in the tender document andinstructionsofEngineer- in-Charge. All materials shall be supplied by Contractor. 1466 Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat,Finish Paint : 3 coats of F-7 @ 100µ DFT /coat. 1467 Design Temperature Range: -29 °CTo 400 °CPrimer: 1 coat of F-16 @125 micron Finish Paint: 1 coat of F-16 @125 micron Remarks: total DFT : 250-300 micron 1468 InternalSurfaces:Surfacepreparation to SSPC-SP-10,applicationofprimerandpaint oninternalsurfaceofbottomplate,shell full height,internal surfacesofcone/dome roof,roofstructure,oil side surfacesofpontoons & deck platesandoil side surfaces of doubledecks,internalladder,structuralsteel, internalsupportandinternalaccessories(exceptheatingcoil)asper painting system defined below and requirementsasgiven in the respective engg.datasheets. Supply of metallic and non-metallic materials, labour, primer andpaint of approved quality, equipment, consumables,etc. to complete the work in allrespect, as per applicable specifications, standardsattached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor. 1469 Design Temperature Range: -14 °CTo 60 °CPrimer: 1 Coat of F-6A@100 µ DFT/coat Finish Paint 2 Coats of F-6A@ 100µ DFT/Coat(2x100=200) Remarks: - 1470 Design Temperature Range: - °CTo - °CPrimer: - Finish Paint 3 coats of vinylchloride co- polymer @ 75µ/Coat; (3x75=225) Remarks: - 1471 EQUIPMENT ERECTION 1472 TOUCH-UP PAINT APPLICATION (UNINSULATED EQUIPMENT) FOR CS VESSEL 1473 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required as per attached specification, providing scaffolding for all heights, labour, material, tools and tackles, consumables, supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge for all type of uninsulated equipment. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint already carried out by equipment supplier. 1474 EQUIPMENT ERECTION:Transportation of reactors, columns, vessels, silencers, heat exchangers (shell and tube, plate fin, plate) and electric heater etc. from owners storage point to work site, assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs, erection of wooden pillow for cold equipments, stacking of multi-tier exchanger(which are stored in unstacked condition), arranging hooks for test ring/ test flanges in heat exchangers, installation of demister, internal gratings, distributor, pipe davit, installation of mixer/agitator,cleaning and flushing by water, draining, drying by compressed air, arranging all tools, tackles, machinery, consumables, transportation equipment, erection equipment, instruments, labour, ancillary, etc. to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1475 Equipment weighing less than 30 MT but 10 MT and above 1476 TOUCH-UP PAINT APPLICATION (INSULATED EQUIPMENT) FOR CS VESSEL 1477 Application of field primers and finish paint(Supply by Others) on C.S vessels, PHE and other equipment, including rubdown and touch up of shop primer (primer as per applicable specification) wherever required, as per attached specification, providing scaffolding for all heights, labour, materials, tools and tackles, consumables and supervision etc. to complete the work in all respect as per specifications, drawings, equipment details for painting and direction of Engineer in-Charge. The surface area is as per respective temperature ranges given in applicable specification. Note: Surface preparation, primer and finish paint shall be provided by equipment supplier. 1478 EQUIPMENT UNLOADING: Unloading of Equipment from trailer at designated receiving point, Transportation of the same and handling over to owner at designated storage point for the following as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1479 Equipment weighing less than 50 MT but 30 MT and Above 1480 Equipment weighing less than 30 MT but 10 MT and above 1481 LETTERING AND STENCILING:Surface preparation, supply and application of primer and paint on insulated and uninsulated equipment for lettering, stenciling on vessels, columns, drums, for the purposes of identification (Equipment Name, Equipment Number & Service Description) as per applicable painting specification enclosed elsewhere in the tender document, arranging scaffolding for all heights, labour, materials, tools, tackles, supervision etc. to complete the work as per specifications and instructions of Engineer-in- Charge. 1482 ERECTION OF DRESSED-UP EQUIPMENT:Transportation of columns and vessels from owners storage point to work site, dressing up of the column/vessel by contractor , assembly of parts, subassemblies, erection at all elevations, aligning, verticality checking, grouting, tightening of foundation bolts, welding of washer on anchor chairs,arranging all tools, tackles, machinery, consumables,erection of completely dressed-up equipment, & arranging allinstruments, labour, ancillary, etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge.Dressing up of column(As applicable as per the requirement of the tender): Supply/Application/installation of insulation, installation of ladders and platforms, installation of piping spool and support (wherever applicable), installation of demister, internal gratings, distributor, pipe davit etc on the Column/Vessel, cleaning and flushing by water, draining, drying by compressed air etc to complete the job in all respects as per the requirements of the specifications & standards attached else where in the tender. 1483 Equipment(Dressed-up) weighing less than 50 MT but 30 MT and Above 1484 ERECTION OF BURIED EQUIPMENT : Transportation of vessels from Owners storage point to worksite, repair/ touch up of finish paint, arrangement of all accessories, equipments, labour etc., placing/erection of vessel in trenches/pits including assembly of parts, subassemblies, aligning, verticality checking, grouting, tightening of foundation bolts,arranging all tools, tackles, machinery, consumables etc to complete the work in all respects as per drawings, equipment detail, specifications and instructions of the Engineer-in-Charge. 1485 Equipment weighing less than 30 MT but 10 MT and Above 1486 WELDING & NDT OF CUT NOZZLES / SUMP / BOOT OF BURRIED VESSELS:Assembly of cut nozzles/Sump/Boot(as shown in Respective Engg. Data Sheet), vertically checking, alignment, Welding of cut nozzles , NDT such as 100% radiography ,UT , surface preparation of the weld seam portion, application of primer, painting, arranging all tools and tackles, machinery. Consumables, transportation/handling of equipment, labour etc to complete the work in all respects as per drawings & instruction of Engineer-in charge. 1487 MOC : Carbon Steel ,Nozzle size : 2 1488 MOC : Carbon Steel ,Nozzle size : 3 1489 MOC : Carbon Steel ,Nozzle size : 6 1490 MOC : Carbon Steel ,Nozzle size : 8 1491 MOC : Carbon Steel ,Nozzle size : 20 1492 MOC : Carbon Steel ,Nozzle size : 24 1493 EQUIPMENT INSULATION 1494 COLD INSULATION: Providing cold insulation including supply of all insulating andanciliarymaterial,protectivecovering,consumablesand othernecessarymaterials,testingofthematerialasrequiredincluding transportationofthematerialstoworksites,applyinginsulationon surfacesasspecified,includingallpreparatoryworksthereon,allbinding, tying,lacing,stitchingand/orotherwisesecuring,providingvapour barrier,finishingwithplain/corrugatedsheetcladdingorasspecified, providingbolts,rivets,providing vapour stop etc.arranging necessaryscaffolding,alltoolsand tackles,equipment,apparatusetc.labourandsupervisionandcompleting theworkinallrespectatallheightsasperdrawings,specificationsand instructionsofEngineer-in-Charge. 1495 Shells of vertical vessels, columns, exchangers, reactors, silencers etc.Surface material:CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1496 Insulation Thickness: 50mm 1497 Shells and heads of horizontal vessels, columns, reactors, exchangers, silencers etc and heads of above mentioned vertical equipments. Surface material: CS/AS. Insulation type:Ic (Polyurethane foam). Service: Other than LNG. 1498 Insulation Thickness: 50mm 1499 STRUCTURAL 1500 EARTH WORK (REFER SPECIFICATION NO. 6-68-0003) 1501 Earthwork excavation in soil 1502 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth upto 1.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1503 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 1.5m and upto and inclusive of 3.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1504 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 3.0m and upto & inclusive of 4.5m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1505 Earth work in EXCAVATION below ground level for all kinds of works in ALL TYPES OF SOILS EXCEPT SOFT ROCK AND HARD ROCK as classified in specification for a depth beyond 4.5m and upto & inclusive of 6.0m including removal of vegetation, shrubs and debris, cutting and dressing of sides in slopes, levelling, grading and ramming of bottoms, dewatering of accumulated water from any source and keeping the surface dry for subsequent works and disposal or stacking of excavated material within a lead of 100m, as directed including providing temporary supports to existing service lines like water pipes, sewage pipes, electric overhead and underground cables etc. all complete, but excluding shoring and strutting. 1506 SHORING AND STRUTTING 1507 Providing and installing approved type of SHORING AND STRUTTING by open timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1508 Providing and installing approved type of SHORING AND STRUTTING by close timbering method for all depths to retain earth including dismantling and removal of the same etc. from site after completion of work etc. all complete as directed. 1509 Backfilling after execution of work 1510 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps within a LEAD OF 100M, including re- excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/ mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1511 BACKFILLING after execution of the WORK to proper grade and level with selected materials from available excavated soil from spoil heaps beyond a LEAD OF 100M AND UPTO & INCLUSIVE OF 500M including re-excavating the deposited soil excavated earlier, breaking clods, laying at all depths and heights in layers of thickness not exceeding 15 Cms. watering, rolling and ramming by manual methods/mechanical compactors to achieve 90% laboratory maximum dry density, dressing, trimming etc. in foundations, plinths, trenches, pits etc. all complete. 1512 Transporting & Disposing the SURPLUS EARTH ANDDEBRIS 1513 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 100M AND UPTO 1KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1514 Transporting and disposing the SURPLUS EARTH AND DEBRIS including shrubs and vegetations from construction area beyond the initial LEAD OF 1.0KM AND UPTO & INCLUSIVE OF 3.0KM including re-excavating the deposited soil excavated earlier, transportation, loading, unloading, laying at all depths and heights, stacking, levelling and dressing both the area (viz. from where the earth is transported and where it is deposited) to required levels and slopes complete with all lifts as directed. For carting on the basis of truck measurements (volume of truck reduced by 30% for voids). 1515 PLAIN & REINFORCED CEMENT CONCRETE: (REFER SPECIFICATION NO. 6-68-0004) 1516 PCC - Non FIM Items 1517 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete of nominal mix 1:5:10 by mass (1 Cement: 5 Coarse Sand: 10 Crushed Stone Aggregates/Gravels) with 40mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1518 Providing and laying PLAIN CEMENT CONCRETE for all depths below and upto plinth level in foundations, drains, fillings, non-suspended floors, pavements & ramps or any other works etc. including shuttering, tamping, ramming, vibrating, curing, etc. all as specified in any shape, position, thickness and finishing the top surface rough or smooth as specified and directed all complete for concrete grade M20 with 20mm and down size graded crushed stone aggregates/Gravels. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1519 RCC Substrutures - Non FIM Items 1520 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. foundations, raft, beams, slabs, pile caps, retaining walls, dyke walls, jambs, counterforts, buttresses, pedestals, pipe sleepers, columns, suspended floors, staircases, landings, steps, brackets etc., including equipment/ machine foundations & pedestals viz. compressors, ID & FD fans, pumps, generators, crushers, mills, etc., (including single pour concreting as specified on the drawing), applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1521 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUB-STRUCTURE e.g. trenches, culverts, manholes, pipe encasement, catchpits, drains, pits, etc., applying cement wash on concrete surface (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering, etc., wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING & SPECIFIED ADMIXTURES) for all depths below and upto plinth level in any shape, position and thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1522 RCC Superstructures - Non FIM Items 1523 Providing and laying REINFORCED CEMENT CONCRETE OF M-30 GRADE with 20 mm and down size graded crushed stone aggregates/ gravel in SUPER STRUCTURE in suspended floors, slabs, beams, columns, walls including counterforts, staircases, landings, steps, facias, fins, mouldings, gutters, shelves, window sills, canopies, lintels, girders, ducts, brackets, chajjas with drip moulds, pedestals, posts, struts, equipment/ machine foundations, ramps etc. (including single pour concreting as specified on the drawing), providing cement wash (wherever no other surface application is specified), providing pockets, openings, recesses, chamfering wherever required, vibrating, tamping, curing and rendering if required to give a smooth and even surface etc. (EXCLUDING THE COST OF REINFORCEMENT, SHUTTERING AND SPECIFIED ADMIXTURES) FOR ALL HEIGHTS UPTO & INCLUSIVE OF 20 m ABOVE PLINTH LEVEL in any shape, position, thickness etc. all complete as specified, shown and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1524 HYD Bars / MS Bars - Non FIM Items 1525 Supplying and placing in position HIGH YEILD-STRENGTH DEFORMED STEEL BARS REINFORCEMENT of Grade Fe500D (TMT) conforming to IS:1786, for RCC work including transporting the Steel, straightening, cleaning, decoiling, cutting, bending to required shapes and lengths as per details, binding with 18 SWG black soft annealed binding wire at every intersection, supplying and placing with proper cover blocks, supports, chairs, overlaps, welding, spacers, fanhooks etc. for all heights and depths etc. all complete as directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1526 Centering and Shuttering - Non FIM Items 1527 Providing and fixing CENTERING AND SHUTTERING in foundations, footings,raft beams, slabs, pile caps, retaining walls, jambs, counter-forts, buttresses, trenches, equipment/machine foundations, pedestals, abutments, pipe sleepers, columns, plinth beams, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/bunkers/ silos/ shafts/ hoppers/liquid storage structures etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1528 Providing and fixing CENTERING AND SHUTTERING in superstrctures in retaining walls, jambs, counter-forts, buttresses, equipment/ machine foundations, abutments,columns, lintels, suspended slabs, beams, staircases, landings, steps, non-circular tunnels/ bunkers/ silos/ shafts/ hoppers/ liquid storage structures etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1529 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in foundations in all types of Structures such as Chimneys/ Shafts/ Silos/ tunnels/ bunkers/ hoppers/ liquid storage structures/ domes/ ring wall for tanks, etc. for all depths below and upto & inclusive of plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1530 Providing and fixing CENTERING AND SHUTTERING for CURVED SHUTTERING in superstructures in all types of Structures such as Chimneys/Shafts/Silos/ tunnels/bunkers/hoppers /liquid storage structures/ domes etc. for all heights above plinth level including shuttering for single pour concreting, strutting, bracing, propping etc., keeping the same in position during concreting and removal of the same after specified period etc. for Straight/ Inclined Shuttering, keeping necessary provision for inserts, projecting dowels, anchor bolts or any other fixture etc. all complete and as specified and directed. 1531 Fixing Re-bars in already cast concrete - Non FIM Items 1532 Designing, supplying and fixing rebars in already cast concrete, including drilling, cleaning hole with air blow-out & wire-brush and injecting odourless Chemical of approved make, packed in dual foil, with the help of dispenser into a hole of diameter and depth as per manufacture specification, at all levels & locations for high strength deformed steel reinforcement bars of dia. 16 mm & 20 mm of Grade Fe500D (conforming to IS:1786), DESIGNED FOR FULL TENSILE ANCHORAGE, including testing (as per manufacturers recommendations), adjusting and making good any damage done to the structure etc. all complete as specified and directed. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE EXCLUDING REINFORCEMENT BARS. 1533 CONCRETE FOR LIQUID RETAINING/LEAK PROOF STRUCTURES (REFER SPECIFICATION NO.6-68-0005 1534 RCC- Non FIM Items 1535 Providing and laying Leak Proof Reinforced Cement Concrete of GRADE M-30 (minimum Cement content shall be as per EIL Specifications) with 20 mm and down size graded crushed stone aggregates/ gravel at all positions and in any shape and thickness, in SUB-STRUCTURE, leaving pockets, recesses, vibrating, tamping, curing, testing (for leak-proofness) and rendering (if required to give smooth and even surface) in foundations, walls , beams, buttresses, columns, piers, slabs, tunnels, basements, storage bins, reservoirs etc. including cement wash (if no other surface application is specified) but excluding the cost of Reinforcement, Shuttering and specified admixtures, all complete as specified and directed. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1536 Water Proofing Comp. - Non FIM Items 1537 Supplying and mixing of approved brand of integral WATER PROOFING COMPOUND in cement concrete, cement mortar etc. as per manufacturers specifications or 1% by weight of cement (whichever is minimum), to make it leak proof/ water tight etc. all complete as specified and directed. 1538 PVC Water bars - Non FIM Items 1539 Supplying and fixing in position 230mm wide x 5mm thick approved PVC WATER STOPS as per manufacturers specifications in R.C.C. Structures including cutting, fixing, jointing by vulcanising etc. all complete as shown specified and directed. 1540 Separation Layer - NonFIM Item 1541 Supplying and laying separating layer of approved polythylene sheet of mass 1 kg/sqm (minimum) in between base slab and the layer of lean concrete, including cleaning, preparing of surfaces, etc., all complete and as directed by the engineer-in-charge. 1542 STRUCTURAL STEEL WORKSSPEC NO. 6-68-0006 1543 General Steel Works - FIM Items 1544 Transporting from storage yard (or any other location as specified by engineer-in-charge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated STRUCTURAL STEEL (of any Grade)at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled/ hollow sections and/or plates/ bent plates in all types of structural frameworks, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified etc., all complete. ALREADY FABRICATED STRUCTURAL STEEL SHALL (WITH CONNECTION BOLTS) BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. 1545 General Steel Works - Non FIM Items 1546 Supplying, transporting, storing, fabricating & erecting in position and testing/ examining bolted and/ or welded STRUCTURAL STEEL WORKS of Grade E350BR / E350B0 (conforming to IS:2062) at all locations and levels UPTO & INCLUSIVE OF 20 m ABOVE HPP/ FGL, including all builtup sections/ compound sections made out of rolled sections and/ or plates/ bent plates in all types of structural frameworks, floor beams, stairs, or any other structural items or accessories to support equipments, piping, conveyor galleries, towers, masts, etc., but excluding silos, bunkers, hoppers, etc., cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints, (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, grouting with Ordinary Grout or premix free flow Nonshrink Grout as specified, including preparation and submission of detailed fabrication drawings, preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per jOb Specification No. B861-000-06-42-PLS-01 after fabrication etc., all complete. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. 1547 Painting - Non FIM Items 1548 Supplying and applying FIELD PAINT SYSTEM of approved quality and shade as per Sl. No. 5.2 of Table 5.0 of JOB Specification No. B861-000-06-42-PLS-01 over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 3.1 of Table 3.0 of JOB Specification No. B861-000-06-42-PLS-01 for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, in OFFISTE (COASTAL) areas as well as UNIT (INLAND & COASTAL) areas. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on Structural steel weight). 1549 Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 4.1 of Table 4.0 of JOB Specification No. B861-000-06-42-PLS-01 for painting over the coat of shop primer & galvanization already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTORS SCOPE. (Unit rate based on weight of steel). 1550 STRUCTURAL STEEL WORKS (TUBULAR/HOLLOW SECTION) (REFER SPECIFICATION NO.6-68-0007) 1551 Yst310 IS 4923 1552 Supplying, transporting, storing, fabricating, erecting in position & testing/examining at all locations and levels, bolted and/or welded STRUCTURAL STEEL WORKS of all types using COLD FORMED (RECTANGULAR/SQUARE) HOLLOW SECTIONS conforming to IS: 4923, Grade Yst-310 of approved make in all type of trusses, purlins, girders, side rails, columns, runners, beams, ties, portals, framework, bracing, brackets, sag rods etc. including all handling straightening/ bending if required, cutting to required size & shape, edge preparation, welding & bolting of joints, providing and fixing end caps and plugging holes, fixing in line and level with necessary temporary staging and removal of the same after erection, grouting with Ordinary/ premix free flow Non- Shrink Grout as specified, preparation and submission of detailed fabrication drawings, preparing the exposed surfaces for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per Job Specification No. B861-000-06-42-PLS-01. all complete as specified and directed (SUPPLY OF ALL MATERIALS INCLUDING PLATES IN CONTRACTORS SCOPE) 1553 MISCELLANEOUS STEEL WORKS SPECIFICATIONS NO. 6-68-0008 1554 Anchor Bolts - Non FIM Items 1555 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED ANCHOR BOLTS of all diameters and nomenclature including nuts, washers, anchor plates, pipe sleeves etc. in foundations, columns, pedestals, slabs, beams, walls etc. or any other place as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading, welding, providing necessary templates and auxiliary dummy structures, if any, necessary tying and welding with reinforcement, adjustment of shuttering & reinforcement/any other fixture, greasing exposed metal surfaces, covering bolts and packing the sleeves with jute cloth etc. all complete as specified and directed.(SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1556 MS Metal Inserts - Non FIM Items 1557 Supplying, transporting, storing, fabricating and fixing in position M.S. METAL INSERT (with lugs) of any shape made out of flats, plates, rolled sections, pipes etc. providing necessary templates, staging, cutting, straightening, if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/ any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support the heavy inserts, painting exposed surfaces with a coat of primer as per EIL Specification No. 6-79-0020 (or as per Job Specification wherever applicable), etc. all complete for all depths and heights as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1558 GI Pipe Sleeves - Non FIM Items 1559 Supplying, fabricating and fixing in position G.I. PIPE SLEEVES of all diameters including providing necessary staging, cutting, straightening if required, bolting, welding as required and embedding in position on both Plain and Reinforced Cement concrete members inclusive of adjusting shuttering & reinforcement/any other fixture, welding where necessary, tying and holding to correct level, line and position, any auxiliary dummy structures to support heavy sleeves etc. all complete for all depths and heights as specified and directed. 1560 MS Chequered Plates - Non FIM Items 1561 Supplying, fabricating and erecting in position at all levels and locations bolted, screwed and/or welded M.S. CHEQUERED PLATES of any thickness in walkways, platforms, stair treads, any other place as directed etc. including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing, welding, preparation and submission of fabrication drawings and preparing the surfaces for painting and applying shop primer as per EIL Specification No. 6-79-0020 (or Job Specification, wherever applicable) after fabrication etc. all complete as specified and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1562 MS Grating Cat. A,B - Non FIM Items 1563 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated Grating for platforms etc., including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening, making the edges smooth, removing the burrs (if required), fixing, tack welding, all complete as specified and directed ALREADY FABRICATED GRATING (WITH CONNECTION BOLTS/CLAMPS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE). 1564 Supplying, fabricating and erecting in position at all levels and locations ELECTROFORGED HOT-DIP GALVANISED GRATING (purchased from approved manufacturer by the Contractor) conforming to EIL Standard No. 7-68-0697 (in walkways, platforms, stair treads etc.) including cutting to required size, shape, making holes, notches, openings of required size, nosing, straightening if required, making the edges smooth, removing the burrs, fixing with manufacturers supplied Hot-dip galvanised clamps, preparation and submission of fabrication drawings, all complete as specified and directed. SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE. 1565 Making openings in galvanized grating for pipes / ducts etc., at all levels and at at all locations by cutting the existing grating and providing 50x6 galvanised flat as toe protection for the openings by welding and application of galvanized paint as per EIL Standard No. 7-68-0697, all complete. Payment shall be made as per number of openings. 1566 MS Rungs - Non FIM Items 1567 Supplying, fabricating, fixing and keeping in position M.S. RUNGS in R.C.C. works at all depths and heights including handling, transporting the steel to site workshop and site of work, straightening, if required, cutting, bending to shape, necessary tying and welding with reinforcement, adjustment of shuttering, cleaning, surface preparation, shop primer as per EIL Spec. 6-79-0020 (or Job Specification, wherever applicable)and two coats of anticorrosive paint of approved quality on the exposed portion of rungs etc. all complete as specified and directed (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1568 Hand Railing 1000mm - Non FIM Items 1569 Supplying, fabricating and fixing in position at all locations 1000mm high INCLINED HAND RAILING (for staircases) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade M.S. Tubes conforming to IS:1239 including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01 preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1570 Supplying, fabricating and fixing in position at all locations 1000mm high HORIZONTAL HAND RAILING (for platforms, walkways, etc. or any other location as directed) consisting of top rail, mid rail and vertical posts (Maximum spacing 1500mm c/c) with 32mm nominal diameter medium grade MS Tubes conforming to IS:1239 and 100x5 MS Toe Plate confirming to IS:2062 (Grade A/B), including straightening if required, cutting, bending, welding, bolting, grouting with ordinary grout, cleaning, surface preparation, hot-dip galvanising (80-85 micron as per IS:4759, IS:2629, IS: 4736, IS:2633), shop primer (1 coat of P6 of 40 micron) as per Sl. No. 4.1 of Table 4.0 of JOB SPEC. B861-000-06-42-PLS-01, preparation and submission of fabrication drawings etc. all complete as specified, shown and directed. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). (Complete handrail work shall be measured as length of top rail only and not length of each element fixed). 1571 Transporting from storage yard (or any other location as specified by engineer-incharge), Storing, Assembling and Erecting in position and testing/ examining, bolted and/ or welded, already Fabricated HAND RAILING for platforms etc. including straightening, cutting, bending (if required) welding, bolting, grouting with ordinary grout, all complete as specified and directed. ALREADY FABRICATED HANDRAILING (WITH CONNECTION BOLTS) SHALL BE PROVIDED TO CONTRACTOR FREE OF COST. SUPPLY OF ALL OTHER MATERIAL IN CONTRACTORS SCOPE. (Complete handrail workshall be measured as length of top rail only and not length of each element fixed) 1572 Mechanical Anchor fastners - Non FIM Items 1573 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 12mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1574 Supplying, handling, transporting to site of work and fixing approved MECHANICAL ANCHOR FASTENERS M.S. bolts of Grade 5.8 or more, GALVANIZED with minimum thickness of 5 microns (approved for use in cracked concrete), of 16mm dia at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush, and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1575 Chemical Anchor Fastner 1576 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 12mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size, testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1577 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete), packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 16mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1578 Supplying, handling, transporting to site of work and fixing approved CHEMICAL ANCHOR FASTENERS consisting of M.S. threaded rod of Grade 5.8, GALVANIZED with minimum thickness of 5 microns and chemical (approved for use in cracked concrete),packed in flexible chemical foil or dual foil type, to be usedwith the help of dispenser, of 20mm dia. at specified positions on concrete floors, roofs, beams (sides and bottom), walls, columns etc. according to manufacturers specifications including all accessories like nuts, washers etc. of required size., testing, necessary scaffolding, drilling of the holes in concrete surface with electric drill, cleaning of holes with air blowout & wire-brush and making good any damage done to the structure etc. all complete for all heights, depths and locations as specified and directed. 1579 Threaded bolts for equipment fixing-Non FIM 1580 Supplying, fabricating, fixing and keeping in position at all levels and locations THREADED BOLTS of Grade C property class 4.8 as per IS:1363 (part 2) of all diameters and length including nuts, washers for supporting equipment on steel structure as directed including handling & transporting, straightening if required, turning from relevant size M.S. rounds to required diameter, threading etc. (SUPPLY OF ALL MATERIALS IN CONTRACTORS SCOPE). 1581 BRICK MASONRY (REFER SPECIFICATION NO.6-68-0009) 1582 CLASS 5.0at all depths -Non FIM Items 1583 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all depths below plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1584 Providing and laying BRICK MASONRY WITH BRICKS OF CLASS 5.0 in cement mortar 1:6 (1 Cement : 6 Sand) in one or more brick thickness and in any shape (excluding circular/curved brick masonry) at all heights above plinth level including the cost of materials, labour, scaffolding/ staging, sampling & testing, soaking of bricks, cutting and laying of bricks, providing recesses, making openings of any shape & size, finishing the joints flush below ground level and raking out the joints above ground level, sealing the gap between masonry and soffit of beam/slab, embedding the fittings & fixtures, curing, etc. all complete as per specifications. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY THE CONTRACTOR. 1585 HALF BRICK MASONARYwith bricks of CLASS 5.0-Non FIM Items 1586 Providing and laying HALF BRICK MASONRY with bricks of CLASS 5.0 in cement mortar 1:4 (1 Cement : 4 Sand)in any shape, including the cost of materials, labour, scaffolding/staging, sampling and testing, soaking of bricks, cutting and laying of bricks, providing openings of any shape & size, raking out the joints, supplying and placing 2 Nos. 6mm dia. M.S. Bars at every fourth course, sealing the gap between masonry and soffit of beam/slab, embedding the fittings and fixtures, curing etc. all complete as per specification. ALL MATERIALS INCLUDING CEMENT SUPPLIED BY CONTRACTOR. 1587 DEMOLISHING AND DISMANTLING (REFER SPEC NO. 6-68-0012) 1588 Brickwork - Non FIM Items 1589 Demolishing BRICKWORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1590 Demolishing BRICKWORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools and tackles, necessary scaffolding, propping, underpinning, cleaning and stacking of serviceable material, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1591 RCC - Non FIM Items 1592 Demolishing RCC WORK (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation & backfilling shall be paid separately under relevant items). 1593 Demolishing RCC WORK (taking all necessary safety precautions) for all heights above plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, straightening, scraping and cleaning of reinforcement bars, stacking of serviceable materials, disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. 1594 Chipping of RCC WORK (taking all necessary safety precautions) by CHISELLING, upto & inclusive of 25mm thickness including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc., cutting, lapping/welding of reinforcement bars as per drawings, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary, all complete at all heights and depths, as specified and directed. (Excavation and backfilling shall be paid separately under relevant items). 1595 Cutting/ Dismantling RCC work in pavement, slabs, beams, columns, etc upto a depth of 450 mm by using vibration-less spark-free Diamond Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter, disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials, all complete as per drawings, specifications and directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1596 Cutting/ Dismantling of RCC block foundations, raft foundations, pile caps, mass concrete, equipment foundations etc. by using vibration-less spark-free Diamond Wire Saw Cutter of make HILTI (or equivalent) at all depths & heights, in hazardous areas within process units & offsite which are fire prone due to presence of hydrocarbon vapours etc. taking elaborate precautions for dismantling as per fire permit, clearance etc. and work is to be done with extreme caution. The work item includes cost of all necessary accessories, tools & tacklesincluding diamond saw cutter , disposal of RCC Debris upto lead of 100 m& for all lifts (taking all safety precautions) including cutting reinforcement bars, embedded structural steel members, with necessary scaffolding, propping and underpinning etc. for all elevations with all labour and materials complete as per drawings, specificationsand directions of the Engineer-in-charge. Payment will be made per sq.m.of cross-sectional cut area. Contractor to submit dismantling plan prior to start of dismantling. Dismantling shall be planned in such a way that each cut piece shall weigh not less than 1.6 MT. 1597 Pockets - Non FIM Items 1598 Making POCKETS/HOLES of sizes upto & inclusive of 200 x200x500mm in RCC/PCC works (taking all necessary safety precautions) by chiselling/drilling, including supply of all tools & tackles, necessary scaffolding etc. cutting of reinforcement bars, cleaning the pockets of all debris, disposal of the unserviceable material to spoil heaps anywhere within the plant boundary all complete at all heights & depths as specified and directed. 1599 PCC _ Non FIM Items 1600 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. disposal of unserviceable material to spoil heaps anywhere within the plant boundary, all complete as specified and directed. (Excavation and backfilling shall be paid separately under relevant items) 1601 Demolishing PLAIN CEMENT CONCRETE work (taking all necessary safety precautions) for all depths below plinth level including supply of all tools & tackles, necessary scaffolding, propping, underpinning etc. stacking of all the demolished concrete material at a designated location within the complex limits, all complete as per specifications and directions of Engineer-in-Charge for further processing in mechanical crushers for generating RA/ RCA as per the specifications. (Excavation & backfilling shall be paid separately under relevant items). 1602 Steelwork - Non FIM Items 1603 Dismantling bolted/rivetted/welded STRUCTURAL STEEL WORK of all descriptions (taking all necessary safety precautions), including supply of all tools and tackles, consumables, necessary scaffolding etc., providing temporary bracings as required, cutting (by flame or saw) gusset plates, bolts, nuts, weldings etc., transporting and stacking of the serviceable materials, cleaning the site of work of all unserviceable materials for disposal to spoil heaps anywhere within the plant boundary, all complete at all depths and heights, as specified and directed. 1604 MISCELLANEOUS ITEMS (REFER SPECIFICATION NO. 6-68-0013) 1605 Anticorrosive - Non FIM Items 1606 Providing and laying 50mm thick ANTI-CORROSIVE LAYER under steel storage tanks with screened dry coarse sand mixed with A90 grade bitumen conforming to IS:73 including mixing in drum, heating to the required temperature, with 3% kerosene if required, tamping, dressing to the required slopes to form hard mass of specified compacted thickness etc. all complete as directed. 1607 Sand Filling - Non FIM Items 1608 Supplying and filling approved SAND of specified quality under floors, in foundations, plinths, tank foundations etc. for all depths and heights including cost of sand, royalties, transportation to site for all leads and lifts, including loading, unloading, spreading in layers of loose thickness not exceeding 150 mm, watering, ramming, compacting with mechanical compactors and/or other equipment to the specified levels to achieve 85% relative density as per IS:2720 Part XIV, including preparation of subgrade to the required slope, providing testing apparatus and testing the degree of consolidation all complete as per drawings, specifications and direction of Engineer-in-charge. The rates shall be inclusive of the cost of all labour, material, equipments etc. all complete . 1609 BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE 1610 Supplying and mixing of approved brand of BI-POLAR CONCRETE PENETRATING CORROSION INHIBITING ADMIXTURE (confirming to EIL Specification No. 6-68-0017) in concrete as per manufacturers specification for protection of reinforcement against corrosion. Supply of admixture in Contractors scope. 1611 BONDING FRESH CONCRETE TO OLD CONCRETE BY EPOXY RESIN BONDING SYSTEM (REFER SPECIFICATION NO. 6-68-0056) 1612 Epoxy Resin - non FIM Items 1613 Providing and applying approved EPOXY RESIN (prepared as per manufacturers recommendation) for bonding of fresh concrete to old concrete in all types of structure at all depths and heights including cleaning of concrete surface, removing of all loose concrete pieces, making rough by chiselling, taking off the skin of concrete, application of Epoxy Resin System by spraying, necessary working platforms, props, scaffolding and other safety measures, removal of same after completion etc. all complete as specified and directed. (Excavation, backfilling, removal of surplus earth, keeping pit dry by pumping/bailing subsoil water shall be paid separately under relevant items). 1614 FIREPROOFING OF STEEL STRUCTURES (REF SPEC NO 6-68-0033) 1615 Concrete - Non FIM Items 1616 Supply and laying of concrete of grade M30 as per Type-I of EIL Standard Specification 6-68-0033 as fire proofing material with 10 mm and down size graded coarse and fine aggregates including admixture around structural steel members (viz. beams, columns, bracings etc.) all complete; cleaning the steel surfaces, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, vibrating, tamping, curing or providing a layer of approved membrane of curing compound, rendering with cement sand mortar (1:3) wherever required to achieve a smooth and even surface, providing L50x50x6 at corners or as specified in the drawing, applying primer on MS nuts, angles and affected surfaces, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS INCLUDING CEMENT TO BE SUPPLIED BY THE CONTRACTOR). 1617 Vermiculite Concrete for Structural Steel - Non-FIM Items 1618 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights upto & including 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1619 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-II of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness around structural steel members (viz. beams, columns, bracings etc.) for the required fire protection from reaching temperature 538 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062 and stiffeners for members exceeding 600 mm depth, supply and welding ofMS nuts on angle and box sections and cover blocks for other sections, supplying, placing and fixing in position galvanized expanded metal sheet with mesh size 4.5 mm x 13.5 mm conforming to IS:412 except on angle and box sections, hot dipped galvanized welded wire fabric reinforcement 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566, and tying the reinforcement to the cover blocks with galvanized 16 SWG tying wire, including cutting, straightening, cleaning, bending, applying primer on MS nuts and affected surfaces, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions at all heights more than 10 m above pavement etc. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1620 Vermiculite Concrete for Equipments - Non-FIM Items 1621 Supply and laying of vermiculite based lightweight cementitious concrete coating as per Type-III of EIL Standard Specification 6-68-0033 as fire proofing material of required thickness on equipment/ vessel skirts, saddles and supports for the required fire protection from reaching temperature 427 degree C; cleaning the steel surfaces and applying primer compatible to vermiculite material if required as per manufacturer specifications, supplying, placing and fixing in position cover plates conforming to IS:2062, hot dipped galvanized welded wire fabric reinforcement of 2 mm dia 50 mm x 50 mm mesh conforming to IS:1566 and tying the reinforcement with the pre welded nuts by galvanized 16 SWG tying wire, including straightening, cutting, bending of the reinforcement, including supplying and welding of additional MS nuts if directed by the Engineer-in-charge, applying primer wherever required, curing or providing a layer of approved membrane of curing compound, patching of damaged portion wherever required to achieve a smooth and even surface, providing chamfering at corners, supplying and laying of non-bituminous polysulfide or silicon rubber mastic sealant at terminating edges/ metal joints, painting the surfaces with sealer coat of epoxy polyamide as base and finish coats of coating system No.1 of NORSOK Standard M-501, including the cost of all labour, materials, specified tests, shuttering, staging, scaffolding, working platforms, approaches, etc. for all shapes and positions. all complete as per specifications and directions of Engineer-in-Charge. (ALL MATERIALS SHALL BE SUPPLIED BY THE CONTRACTOR). 1622 Mechanical works 1623 Supplying, fabricating and erecting in position MS plates as per detailed drawings, conforming to grade A of IS:2062 on top of all RCC pedestals supporting the sliding saddles of equipments, including cutting, straightening where necessary, rounding rounding unfinished edges by grinding, machining the exposed top surface, making necessary bolt holes, providing and laying ready mixed free flow non-shrink grout below the base plate at all levels & locations, machining top surfaces etc. all complete and as shown and directed. 1624 SAFETY (REFER EIL SPECIFICATION) 1625 Safety Structures - Non FIM Items 1626 Supplying, Transporting, Storing, Fabricating & Erecting in position and testing/ examining bolted and/ or welded Structural Steel Works at all locations and levels in HANGER SCAFFOLDING below piperack, comprising of hangar channels, fabricated pen wen ladder beams, steel planks bent to shape and size and any other sections, if required, all as per sketches/ specifications and load tested for statisfactory performance, including cutting to required size, straightening/ bending if required, edge preparation, cleaning, preheating, bolting/ welding of joints (including sealing the joints of box sections with continuous welding and plugging any open ends & holes of box sections), finishing edges by grinding, fixing in line and level with temporary staging & bracing and removal of the same after erection, including preparation and submission of detailed fabrication drawings, preparing the surface for painting as per BIS codes after fabrication etc. all complete as specified and directed. All items shall be removed & carried back by Contractor as per instructions of Engineer-in-Charge after completion of works. (Supply of All Material In Contractors Scope). 1627 Providing and fixing double scaffolding system of any height made with 40 mm dia MS tube 1.5 m centre to centre, horizontal & vertical tubes joining with MS tubes, MS tube challies, MS clamps and MS staircase system in the scaffolding for working platform/ staircase etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc., wherever required for inspection of work at required locations with essential safety features for the workmen etc., all complete as per directions and approval of Engineer-in-charge. (Height shall be measured from Floor/ platform from where scaffolding is erected) including providing Aluminium ladders for safe acess of workers. 1628 Supply of Safety Personnel 1629 Supply of HSE personnel SAFETY STEWARD over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1630 Supply of HSE personnel SAFETY SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1631 Supply of HSE personnel SAFETY OFFICER over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1632 Supply of HSE personnel HOUSE-KEEPING SUPERVISOR over and above the requirement as specified in EIL Standard Specification No. 6-82-0001 at site as per the written instructions of Engineer-in-charge (the rates shall be inclusive of all other payments such as PF, ESI, other benefits payable to the workmen as per the prevalent labour laws). 1633 GENERAL CIVIL 1634 TANK PADS 1635 PVC Liner 1636 Providing and laying of PVC LINER of thickness 30 MIL conforming to IS:15909 below tank pad foundations or any other placeat all heights & depths without any damage during subsequent activities including handling, transportation, unloading, storage, laying in position, jointing & overlapping as per manufacturers recommendations, including supply and providing Asphalt impregnated fiberboards for anchoring, etc., all complete as per drawings, specifications and directions of Engineer-in-charge. (All materials including consumables shall be in contractors scope of supply) 1637 Providing and laying in position 80mm dia. perforated uPVC pipes conforming to IS:9271 wrapped with 125mm thick layer of 40mm down size stone aggregates in Geotextile fabric, Terrum T 700 / equivalent, below tank pad foundations for all heights & depths complete as per drawings, specifications and directions of Engineer-in-Charge. (All materials including consumables shall be in contractors scope of supply) 1638 Providing and installation of uPVC leak detection well arrangement comprising of 80mm dia. uPVC pipe, tee, blind flange & threaded cap conforming to IS:13592 for leak detection purpose below tank pad foundations at all heights & depths including providing proper jointing as per code requirements or manufacturers recommendations for fitting in already installed uPVC pipes etc. all complete as per drawings, specifications & directions of Engineer-in charge. 1639 GENERAL CIVIL 1640 SITE GRADING & ROCK CUTTING FOR SITE GRADING 1641 Earthwork in excavation for general site grading, roads, embankments, etc. for all heights and depths in all types of soils except soft and hard rock, including clearing and stripping of the areas earmarked for excavation, removing shrubs, grass, bushes, vegetables growth and other objectionable materials, trees up to and inclusive of a girth of 30 cms. (girth measured at a height of one meter from ground level) including uprooting of roots, etc. taking spot levels, excavating to required depth, leveling, dressing and consolidating the excavated surface, sorting out the excavated soil into serviceable and unserviceable materials, transporting and stacking serviceable materials to demarcated areas anywhere inside plant boundary limitas per instructions of Engineer-in-Charge and disposal of unserviceable material anywhere inside plant boundary limit. All complete as per drawings, specifications and directions of Engineer-in-Charge. 1642 ROADS & FLEXIBLE PAVEMENT (UPTO WBM/WMM LAYER) 1643 Earthwork in filling with approved available earth for all heights and depths for road embankments, shoulders or any other place as directed to proper levels, slopes, grades and camber with selected earth (having CBR 8%) obtained from approved approved areas for all leads from Complex Limit including excavation of earth at approved areas, clearing and stripping at approved areas (if necessary) loading, unloading, transportation etc., clearing and stripping as per specifications, uprooting of vegetation, roots and disposal of the shrubs, bushes, roots etc., breaking clods, spreading in layers not exceeding 20 cm loose thickness, watering, ramming and compacting with road roller to give at least 97% of laboratory dry density with heavy compaction as perIS:2720 Part-VIII, providing testing apparatus and testing the degree of consolidation, dressing and leveling, etc. complete including disposal of allunserviceable materials if any within the boundary limit for all leads etc. as per drawings, specifications and directions of Engineer-in- Charge. 1644 Supplying and Laying of Wet Mix Macadam (WMM) in BASE COURSE (Section 406 of MORTH Specification of Road & Bridge works) using tough, clean, sound & durable stone aggregates including premixing the material (mixing in Plug Mill/ Pan Type Mixer), including transportation to site, laying & spreading in layers not exceeding 125 mm compacted thickness & rolling with vibratory roller 80-100 KN static weight or equivalent capacity to proper grade, camber & level with all leads & liftsetc. complete as per drawing, specifications (MORTH, EIL) & directions of Engineer-in-Charge. 1645 Supply of forged/ cast fittings 1646 Supplying the following forged fittings and flanges, conforming to piping material specifications of tender documents and delivering the same to Owners stores/workspot etc. all complete as per the directions of Engineer-in- Charge. 1647 Elbow 90 Degree for following Nominal Sizes and Piping Material Class 1648 Dia. 12 InchPipe Class A33A 1649 Dia. 3 InchPipe Class A91A 1650 Elbow 45 Degree for following Nominal Sizes and Piping Material Class 1651 Dia. 6 InchPipe Class A33A 1652 Dia. 8 InchPipe Class A33A 1653 Dia. 12 InchPipe Class A33A 1654 Dia. 3 InchPipe Class A91A 1655 Eccentric Reducer for following Nom. Dia. 1 x Nom. Dia. 2 and Piping Material Class 1656 Nom. Dia. 1 8 InchNom. Dia. 2 6 InchPipe Class A94A 1657 Equal Tees for following Nominal Sizes and Piping Material Class 1658 Dia. 12 InchPipe Class A33A 1659 Dia. 3 InchPipe Class A91A 1660 Flanges, complete with nuts, bolts, gasket etc., for following Nominal Sizes and Piping Material Class 1661 Dia. 3 InchPipe Class A91A 1662 Supplying the following spectacle blind assembly consisting of two number flanges, spectacle blind, nuts, bolts, gasket etc. complete conforming to piping material specifications of tender documents and all complete as per the directions of Engineer-in-charge. For following nominal size and piping material class 1663 Dia. 3 InchPipe Class A91A 1664 MISC. CIVIL AND STRUCTURAL WORKS FOR U/G PIPING AND OTHER CIVIL WORKS 1665 Providing and laying brick masonry with locally available bricks of specified class (Brick of class lower than specifiedshall not be accepted) in cement mortar 1:4 (1 cement : 4 Coarse sand) in one or more brick thickness and in any shape in foundation and plinth for valve pits, drains, circular/square maholes, wing walls, etc. including providing recesses, openings, etc. including curing, finishing the joints flush below ground level and raking out joints in plinth with all labour and material, etc. complete as per drawings, specifications and direction of Engineer-in-Charge.For following Brick Class. 1666 All materials including cement supplied by the Contractor and Following Brick Class 1667 Brick Class 5 1668 Providing 13mm thick average cement plaster in cement mortar 1:3 (1 cement: 3 sand) on brick walls/stone masonry/pitching or on concrete surfaces for manholes, valves pits, culverts, wing walls, etc. including cleaning and preparation of the surface, scaffolding, curing etc. for all depths and heights complete as per drawings specifications and direction of Engineer-in-Charge. 1669 All materials including cement supplied by the Contractor. 1670 MISCELLANEOUS ITEMS 1671 Supply and installation of combined safety shower and eyewash units as per spec. no.6-66-0038, including providing and fixing of necessary foundation bolts in foundations/ pavement etc. complete. Each safety shower shall have proper sign board with florescent letters showing their location, all complete as per specification, drawings and direction of Engineer-in-charge. 1672 Supplying & Laying 60mm thick interlocking Paver Blocks for footpaths and any other place etc. including providing 40 mm thick sand filling below Paver Blocks including compaction of sand layer, filling the joints by dry sand, providing precast kerb stone of PCC M 30 at edges and at every 6.0m across the foot path, including preparation of compacted base/ sub base etc. all complete as per drawing, standard, specificationand directions of Engineer-in-Charge. (All material including cement supplied by contractor, paver blocks shall confirm to category A as per IRC SP63. Colour and shape of paver block shall be as per Owner requirement.). 1673 Modification Works 1674 MODIFICATION AND EXTRA WORKS ( IF ANY ) Cuting,bevelling,fitup,welding of different sizes of CS piping of all thicknesses in shop ,in position, on ground and at all elevations, transportation of pipes,fittings,flanges etc. from owners storage point to work site/workshop,making necessary scaffolding,consumables,machinery,tools,tackles,labour and supervision including attending to repairs for completing the work as per instructions of Engineer -in -charge 1675 Flame cutting CS piping 1676 Beveling CS piping 1677 Fit-up and welding CS piping 1678 Removal and re-installation of fire hydrant 1679 Removal and re-installation of firefighting equipment (Fire Hydrant), including isolation valve and transporting the equipment, valve, flanges from removal point to work spot, and fixing of nuts, bolts, washers, gaskets as needed for fixing the equipment with matching flange etc. complete, including plugging the existing branch with blind flange as per specification, drawings and directions of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1680 NDT Testing 1681 RADIOGRAPHY :- Performance of radiographic inspection on piping of all types & thicknesses including providing or hiring of all necessary equipment and whatever else even though not expressly mentioned but required to perform the work as per specificationsand instructions of Engineer-in-Charge. Radiographs shall be submitted to the Engineer-in-charge. (Repeat Radiography due to defective radiograph on repaired joints due to Contractors fault and for additional radiography necessitated due to poor performance of contractors welders shall be done at contractors cost) Note: Unit for radiography quantity is Nos of circumferential weld joints. 1682 FOR JOINTS THK. <= 8MM (FOR CS OTHER THAN CLASS lV OF SPEC FOR NDT REQUIREMENT OF PIPING) 1683 Nominal Dia. 3 Inch 1684 Nominal Dia. 4 Inch 1685 Nominal Dia. 6 Inch 1686 Nominal Dia. 8 Inch 1687 Nominal Dia. 12 Inch 1688 Micrograding 1689 Micrograding of the area as directed to proper level, grade and camber including earthwork in excavation in all types of soils up to a maximum depth of 150mm, removing shrubs, vegetation bushes, grass etc., earth work in filling with select material from available earlier excavated soil and borrow earth (in case the select material from excavated soil is short for filling, filling shall be done with borrow earth, supply & transportation of borrow earth shall be paid separately under relevant item) up to a maximum compacted thickness of 150mm by spreading in layers not exceeding200mm loose thickness, watering, ramming & compacting with road roller or hand roller including hand ramming where road rollers or hand rollers are not accessible to give at least 90% of max. laboratory dry density as per IS:2720 part VII, including transportation, leveling, dressing, disposal of surplus earth, debris, etc. all complete as per specifications, drawings and direction of Engineer-in-charge. (Disposal areas shall be anywhere within the plant complex limit as identified by Engineer-in-Charge.) 1690 Dismantling works 1691 Removal of existing A/G piping 1692 Removal of existing A/G piping of all thickness including cutting, unbolting of flanged joints / cutting of pipe lines wherever required, removing supports, all fittings, flanges etc., cutting of pipes in appropriate lengths for transporting purpose, transporting all material to owners storage point within the complex as designated by Owner including stacking of material and disposing of waste etc. as instructed by Engineer - in - charge. 1693 For C.S. A/G Pipe of following nominal dia. 1694 Nominal Dia 8 Inch 1695 Nominal Dia 4 Inch 1696 Nominal Dia 6 Inch 1697 Nominal Dia 12 Inch 1698 Removal of existing U/G piping 1699 Removal of existing U/G piping including excavation in all types of soils except soft rock and hard rock, including supply of any additional material required so as to expose the pipes for removal / dismantling, taking all safety precautions, supporting existing U/G services, dewatering of surface / sub-surface water as required to facilitate dismantling of pipes, cutting of pipes in appropriate lengths for transporting purpose, removal of soft material from bottom of trench and compacting, backfilling with available selected earth including re-excavating the deposited soil excavated earlier, breaking clods, laying in thickness not exceeding 15cms, watering rolling and ramming by manual methods / mechanical Compactors to achieve 90% laboratory maximum dry density as per IS:2720 Part VII or 85% relative density as per IS:2720 part XIV as applicable, stacking of serviceable / unserviceable material, transporting and stacking of all piping material to Owners storage point, disposal of unserviceable material anywhere inside the complex etc. , all complete as per directions of Engineer-in-Charge. 1700 For CS Piping dismantling, Thickness <=10 mm , For following Nominal Sizes 1701 NB 2 inch - 6 inch 1702 NB 8 inch - 14 inch 1703 Portable/ trolley mounted Extinguishers 1704 Supply and installation of portable DCP ( Dry Chemical Powder Type) extinguisher including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification and directions of Engineer-in-Charge. 1705 Capacity in Kg 10 1706 Supply and installation of portable CO2 extinguishers including transporting to worksite, fixing in position including all accessories and all labor and material etc. complete as per drawings, specification, data sheet and directions of Engineer-in-Charge. 1707 Capacity in Kg 4.5 1708 Capacity in Kg 2 1709 Painting of A/G pipes and valves 1710 Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines. 1711 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes 1712 Nominal Dia. 12 Inch 1713 Nominal Dia. 4 Inch 1714 Nominal Dia. 3 Inch 1715 Nominal Dia. 6 Inch 1716 Nominal Dia. 8 Inch 1717 Painting of uninsulated surfaces for Industrial marine environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes 1718 Dia. Of Valve 12 Inch 1719 Dia. Of Valve 4 Inch 1720 Dia. Of Valve 6 Inch 1721 Dia. Of Valve 3 Inch 1722 Dia. Of Valve 8 Inch 1723 Fabrication and Erection of piping (underground) 1724 FABRICATION AND ERECTION OF PIPING (SPEC. NO.6-65-0030 and 6-44-0012) : Laying and joining of Carbon Steel pipes and specials underground including transportation of all material from Owners storage point to worksite, earthwork in excavation in all types of soilEXCLUDING SOFT ROCK AND HARD ROCK for pipe trenches, saddles, etc. including dewatering of rain and /or sub soil water, shoring & strutting if required, dressing of sides, levelining, grading & ramming of bottom of trench, cutting of pipes if required, fitup, edge preparation, providing corrosion protection tape coating as per specification, on pipes and specials, laying the pipes in trenches to required alignment and levels, welding the same after laying, installation of flanges, blind flanges, tapping for pressure gauges, temperature gauges and all other online instruments and fittings like elbows, reducers, tees, flanges, spectacle blinds and spacer blinds etc., as per piping material specification, fixing of nuts, bolts, gaskets and washers, welding, corrosion protection coating of field joints, cutting of road wherever required and making good the same, testing for the corrosion protection coating as per specification, cleaning and flushing by water/ compressed air, hydrostatic/ pnuematic testing of the system, flushing, backfilling the trenches with select material from available excavated soil including re-excavating the deposited soil excavated earlier, breaking clods and laying in layers of 15 cm compacted thickness, watering, compacting with mechanical means like vibro rammers etc. to 90% of dry density as per IS:2720 Part-VII, disposal of surplus earth/ unserviceable material to demarcated area anywhere within the complex limit etc. complete as per drawings, specifications and instructions of Engineer-in-Charge including connecting the pipes to manhole, including return of all unused / scrap pipe to owners storage point (Pipes and fittings shall be supplied by owner as free issuematerial.) (Depth of excavation for pipe trench shall be upto 3.0m) 1725 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1726 Fabrication, For the following nominal sizes 1727 NB 2 inch - 6 inch 1728 NB 8 inch - 14 inch 1729 Erection including corrosion protection coating, for Water System (Pressure Piping), Forfollowing Nominal Sizes 1730 NB 2 inch - 6 inch 1731 NB 8 inch - 14 inch 1732 Erection including corrosion protection coating, for Waste Water Collection System (Gravity Flow), for following Nominal Sizes 1733 NB 2 inch - 6 inch 1734 Fabrication and Erection of piping (Above ground) 1735 PIPING (ABOVE GROUND): Transportation of all piping items from owners storage point to work site/workshop, fabrication including cutting, edge preparation (including grinding the edges of pipe, fittings, flanges etc. to match with the mating edges of uneven/different thickness wherever required), fitup, bending, preheating wherever required, welding, threading, and laying of pipes of all type and thickness over pipe sleepers, overhead on racks and at all elevations, connectingwith equipment nozzles, strainers, orifice assemblies, tapping for pressure gauges etc., fixing of gaskets, bolts, nuts including application of torque wherever required and all other inline instruments and fitting like elbows, reducers, tees, vents, drains, SW valves upto 1.5 NB, alignment, cleaning & flushing by water/compressed air, hydrostatic, pneumatic, vacuum, spark testing and any other type of testing as specified,draining, drying by compressed air completing all such works in all respects (including preparation of isometrics as mentioned in the scope of work for the job)as per drawings, specifications and instruction of Engineer-in-charge. (Pipes and fittings shall be supplied by owner as free issue material) 1736 Carbon SteelPiping (Non IBR), Thickness <=10 mm 1737 Fabrication, For the following nominal sizes 1738 NB 2 inch - 6 inch 1739 NB 8 inch -14 inch 1740 Erection , for Water System (Pressure Piping), Forfollowing Nominal Sizes 1741 NB 2 inch - 6 inch 1742 NB 8 inch -14 inch 1743 Supply of Carbon steel pipes 1744 Supply of Carbon steel pipes as per Piping material class including transportation of all material to owners store complete as per drawings, specifications and instruction of Engineer-in-Charge. For following nominal size and piping material class. 1745 Nominal Dia. 12 InchPiping Material Class A33A 1746 Nominal Dia. 4 InchPiping Material Class A33A 1747 Nominal Dia. 8 InchPiping Material Class A33A 1748 Nominal Dia. 6 InchPiping Material Class A33A 1749 Nominal Dia. 3 InchPiping Material Class A91A 1750 Supply and installation of valve assembly, flange assembly etc. 1751 Supply and installation of valve assembly consisting of valve, 2 no. flanges, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1752 Gate valve assembly for following nominal sizes and piping material class 1753 Dia. 12 InchPMS A33A 1754 Dia. 8 InchPMS A33A 1755 Dia. 6 InchPMS A33A 1756 Dia. 3 InchPMS A91A 1757 Supply and installation of valve assembly consisting of valve, 1 no. flange, 2 no. gaskets and 2 sets of nuts & bolts per valve assembly, erection of valve in position including fixing of nuts, bolts, gaskets, washers etc. complete as per drawings, specifications and directions of Engineer-in-Charge. 1758 Dia. 4 InchPMS A33A 1759 Dia. 6 InchPMS A33A 1760 Globe valve assembly for following nominal sizes and piping material class 1761 Dia. 3 InchPMS A91A 1762 Supplying the flange assembly conforming to piping material specifications and delivering the same to owners stores/ work spot etc. Flange assembly shall consist of 2 no. flanges along with one no. matching gasket and one set of matching nuts &, bolts. All complete as per specifications and directions of Engineer-in-Charge. For following nominal size and piping material class 1763 Dia. 3 InchPMS A91A 1764 Supply, Fabrication and installation of strainers 1765 Supply, Fabrication and installation of strainers as per drawingsetc. complete as per specifications and directions of Engineer-in-Charge. 1766 T-type strainers for following nominal size and piping material class 1767 Dia. 3 InchPMS A91A 1768 fire fighting equipments 1769 Supply, installation, testing and commissioning of following firefighting equipment as per relevant specifications, data sheet, drawing, including transporting the equipment to worksite, fixing of nuts, bolts, washers, gaskets, welding needed for fixing the equipment with matching flange etc. all complete as per drawings, specifications, standards, data sheet and direction of Engineer-in-Charge. 1770 Double headed landing valve 1771 First Aid hose reel wall mounted type 1772 Hose box cabinet Type-II (Wall mounted type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1773 Hose box cabinet Type-II (self-supporting type) including all inside accessories, including all civil works, fixing in position with anchor bolts in foundations or wall 1774 Variable flow Water cum foam monitor of 500/750/1000 GPM capacity 1775 Stand Post Type Fire Hydrant without Pumper Connection 1776 Miscellaneous Items 1777 Miscellaneous 1778 Design, engineering, procurement, supply of all materials and equipment, machinery, civil, structural, electrical, mechanical, instrumentation, piping works including painting works, tape coating on U/G piping, commissioning spares and tools/tackles as per scope of work, specifications, drawings, data sheets etc. and as per directions of Engineer-in-Charge for Auto Actuated High Velocity Spray System on Transformers including taking approval of the complete system from agency appointed by insurance company /Client. Unloading at site, handling, transportation from store to work site, storage at site, fabrication, construction, assembly at site, supply of all labour, installation, field works including civil structural, electrical, mechanical, instrumentation, piping works and supports, testing, pre-commissioning, painting, commissioning and any other activity required to complete the works in all respects including performance guarantee run, handing over to client as per enclosed scope of work, drawings, specifications, instructions to vendors, data sheets and as per directions of Engineer in- Charge. Supply of mandatory spares as per specifications enclosed list/instructions to vendor as per scope of work and specification, drawings and documents as per attached vendor data requirement for all supplies and services etc. complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 6
34.
Defence #9528620 AOC
Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the rate shall be quoted by the bidder. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units including indoor and outdoor unit complete of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 BLANK 24 BLANK 25 BLANK 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 100 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 400 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No.(iii) Aluminium Bus bar TPN - 600 amps- 1setOUTGOING(i) MCCB 3 Pole 200 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release- 02 No.(iii) MCB TPN 32 Amp - 03 Nos.(iv) 80 HP S/D soft STARTER- 02 Nos.(v) DOL STARTER 7.5 HP- 02 Nos.(vi) Motor Protection Relay32-88 amps- 2 nos. (vii) Motor Protection Relay2- 5.5 amps- 2 nos. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 4 Nos. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply and fixing single unit flame type detectors (Triple IR infrared flame detectors) Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relaying type module) complete all as specified and directed 78 Supply and fixing,Test and Drain valve 65/50mm, forged brass body, brass chrome plated ball, 304SS stem with Polycarbonate sight glass, indicator and handle made of steel complete all as specified and directed 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Double mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on rails at the bottom to traverse the length of the storage system. Top rails mounted on the racking system shall also support it. PMDC motars should be used with required counter weight for better efficiency of verticle travel.General technical parameters of stacker crane:Technical parameters/Type- Double Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system:- Two single aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelDouble mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system during the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASR system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1)Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane. An additional antifall device must be provided for the lifting carriage. In the event of electromagnetic break motor failure or malfunction, this device should automatically engage to safely hold the carriage and prevent any freefall, thereby avoid accidents due to emergency brake failure.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASR system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: 1) Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integrated. Changes in make of different components of ASR system and minor changes in different parameters are permitted with approval of Accepting Officer as per recommendation of ASR system manufacturerprovidedthe end objective of the system is complied.2) The ASR system is to be installed in Bulk store house complex. Necessary civil works for installation of the ASRS required in the building is included in the scope of this item. Neccessary arrangements for integration of system with flooring and overhead trussess of the building shall be done at appropriate stage and shall be included in the rates quoted3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptanceMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advanced Inventory Management System with compatibile computer hardware and integrated inventory and weight management system with PLC based software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height(Min) : 6400 (±100) mm(ii) System Width(Min) : 3150 (±100) mm(iii) System Depth(Min) : 2300 (±100) mm(iv) System Base(Min) : 7.24 Sq.Mtr(v) Tray Int. Size(Min): 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight(Min) - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 Kg(Min)Technical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(Min)(x) Storage surface area per system - 39.2 sq mtr(Min)(xi) Door - Automatic, (xii)Power supply - 440V, 50/60 Hz, 3 Phase(xiii) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xiv) Chain - Diamond makeor equivalent, (xv)Bearing - SKF/NTN make or equivalent(xvi) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: 1) The system and software provided under this item shall be of same make as for item 13.066 to 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system.2) Comprehensive maintenance of the system during two years of defect liability period shall be a part of this item and rates shall be quoted accordingly. Comprehensive maintenance shall include all spares including software update. The ASR and advanced management system shall be operated by single warehouse management system.3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptance 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS, 100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCB, TPN 40 Amp, 415 Volt, C Curve - 03 Nos.(b) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(c) Digital ammeter - 2nos.(d) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV / 0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro/Bajaj 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing and commissioning of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 MMake: Precitech thermal Pvt. Ltd., Rram Buisiness corp, Alfa therm Ltd., Thermax Ltd, Kanti Industries, Fortec 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories: Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(b) Radiator with blower fan or heat exchanger with guard.(c) Pipe coupling for engine cooling system piping.(d ) Corrosion inhibitor coolant(e) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(f) Fly wheel housing and fly wheel to suit alternator.(g) Engine bearing mechanism in fly wheel housing.(h) Shut off coil with safeties for LLOP/HWT/over speed.(i) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Battery charging alternator.(m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of30 gauge for the entire length of exhaust pipe.(o) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(p) Interconnecting copper cabling of adequate capacity batteries control.(q ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(r) Self starter 24 volts DC.(s) Electric operated electronic governor.(t) Fuel injection pump.(u) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(v) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (w) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(x) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(y) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling for exterior canopy (without opening its panel) etc complete all as specified and directed.(z) Isolator panel with 630 amp MCCB(aa) Auto logic panel for automatic stat(ab) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof, insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(ac) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(ad) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (ae) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(af) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No. EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(i) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(ii) Bottom gland plate for incoming and outgoing cables.(iii) Circuit diagram plate.Note:- DG set should be as per CPCB- 4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.The contractor shall procure the item within the period given by CPBC in case of revision in CBPC norms. Nothing extra will be paid on account of delay from the part of contractor. DG set shall have an exhaust with stack height of minimum 2m from the top of generator with a cowl. Smoke released from the exhaust of the DG sets indicating that emission parameters are within permissible limits, as prescribed by CPCB, demonstrating compliance with emission limits prescribed by CPCB 2016. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 set(d) Horizontal aluminium bus bar for 3 phase 440 V, 50 Hz, 4 wire system of rating 800 Amps for phases and 800 Amps for neutralOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 03 No. (for Package AC Bulk Store, pump house and fire pump & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The Energy Meter to be capable of running in both prepaid and postpaid mode.(b) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 155 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Initial load test (pull outtest as per design load) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 158 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 159 Testing of piles Initial load test (verticle load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed 160 M & L for carrying out Initial Load test (lateral load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note:- Providing and installing test piles shall measured and paid separately) 161 M & L for carrying out Initial load test (pull outtest as per design load)of cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 162 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
Contract Date: Feb 11, 2026 Contract Value : 59.27 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
35.
Drinking Water Supply and Sanitation #9513897 Technical Bid
Tender for Kalpi Npp Water Supply Scheme District Jalaun Construction Of Intake Footbridge Wtp Oht Rising Main Distribution System And Electrical Mechanical Works Under Kalpi Npp Water Supply Scheme District Jalaun - W.T.P -Design (hydraulic and structural ), construction, (including topographical survey, geotechnical investigation and other Surveys as required) for specified capacity of WTP based on 20 Hrs. operation including inlet chamber, aeration fountain / cascade, inlet channels ,chemical building ,including mechanical/manual fine/coarse screens, flash mixer, mixing channel with Parshall flume and flow measuring arrangement, clariflocculator with conventional, filter house and filter plant including back wash tank and back wash pumps with 100% standby, chemical house, coagulant feed tank with feed mechanism, poly aluminium chloride (PAC) or other coagulant tank of specified capacity and nos. with mixing and dosing arrangement complete, vacuum feed gas chlorinator with 100% standby ,safety equipment’s &EOTcrane,pressureandleveltransmitterfor pumpingplant,turbidity, TDS, PHAnalyzer,chlorineanalyzer,ROFTandLOHTforfilter house,flowtransmitterultrasonic/electromagneticatinletandoutletandFilter backwashwithentirepipingsystem , sludge handling unit and recycling of collected water from sludge , etc. complete to achieve desired perameters of clear wateras specified in tender document andin accordace letest C.P.H.E.E.O.Manual,/ltest guidline/ I.S. Codes/Govtt. Orders . All WTP scada Opratedexternal and internal electrification, laboratory building with all specified lab equipment, admin building,Sub station building (L.T./H.T. Room), Platform for Transformer,Meter Room ,chlorine Room,Staff Quarter (Type III-one Number), sanitary block with necessary water supply and drainage arrangement, campus roads (Interlocking Road/C.C.Road), landscaping( earth filling up to 115.00level including levelling and dressing of Campus )and other campus development works with rain water harvesting and garden, etc. all required works complete as per the direction of Engineer-in-Charge in Pile Foundation .The WTP shall be fully automatic prefrablybased onRapid sand gravity filter or any proven technologysuitable to treat Raw water from yamuna river throug out the year , PLC/SCADA with real time remote monitoring system and online contineuous effluent monitoring systemincluding Soil testing, Design ,S/o all labour ,material T&P etc. required for proper completion of the work as per letest IS Codes ,manuals ,instruction of engineer in charge and tender document. 2 INTAKE WELL- Supply of all materials, labour, T&P etc.as requiredforDesign and construction of Intake- well - cum - pump house of 9.0 m. internal dia. The intake well upto floor level shallbe firmly based on suitable foundation made with well sinking tecgnology including construction of coffer damand Annular raft/ well foundation , including construction of 1.20 m. wide R.C.C. balcony at plinth level, construction of Pump House made of brick masonry, duly embraced within R.C.C. column, and fitting of doors and windows, making opening arrangement at floor level of pump house (9.00 m. dia and 6 m. height)and construction of 1.20 m. wide R.C.C. balcony at Pump house floor levelincluding S.S. Rolling Shutter, steel cage hinged with locking arrangement, duly supported on steel girder. Plateform for transformer ,meter room andSubstation Building (HT pannel room,LT pannel room ) Ventilator arrangement along with fixing of required size dia. DID/F pipesand Sluice Valves- 3 Noat inlet etc. as per site requirement or as per the design. The work also includes steelrailing(grad 304 ) in three rows on both sides of pump house balcony and fixing of 0.5m. wide M.S. ladder made of 50 x 50x 6mm. angle iron ladder from floor of pump house to floor of intake well, duly supported on R.C.C.landing at suitable interval. The ladder shall run spirally inside the intake well and each landing shall be supported on R.C.C. M.S. channelpost, spaced not more than 1.5 m. interval including Construction of R.C.C. foundation block as required also include provision for dismantling and reinstatement of stone pitching,removal earth of Coffer dam to maintain flow through-out the year ,Approch roadup to Approch bridge etc up to completion of work as per insrtuction of engineer in charge and tender document . 3 The floor of pump house & balcony shall be of Kota Stone etc. complete. Frames for doors / Shutter shall be made of 50x50x5 mm. M.S. angle iron and ionized and shall be partly panelled and glazed, made of suitable steel sections, conforming to relevant BIS. The work also includes painting of all concrete surfaces with three coats of approved paint and painting of pipes, doors, windows with anticorrosive paints including design of intake well, foot bridge, pump house etc. considering seismic and other forces as per relevant BIS requirements. 4 Design and construction of 4.0 mts. wide R.C.C Foot bridge from Intake well to bank of river for length of 350 mtsminimum height of foot over bridgeslab should be equal to level of floor level of Pump House. pier of bridge in well shinking foundation minimum two Beam below deck slab with bearing support. Provision for padestal construction to rising main pipe fixing with anchor Clamping ,casing pipe for electric cables . Also including Supply& fixing ofstainless steel (gread 304) railing both sides of foot bridge , floor shall be plain chequered tiles, Statinless steel gate at entry gate of Approch bridge with locking arrangmentsup to completion of work as per insrtuction of engineer in charge and tender document . 5 Construction of R.C.C Over Head Tank (OHT)Supply of all the materials, labour T&P and construction of a R.C.C. Over head tank above ground level with main components, based on IS-3370 and IS 11682 or liquid storage concrete in over head tank and foundation concrete as per specification in I.S. 2911.Following capacity/StagingAll Components of OHT will be casted in M-30 concrete with cement, coarse sand and approved stone grit asI.S. 456.Minimum depth of founditation below original ground level will be 2.0 M and in pile Foundation .Seismic effects and wind load should be taken into consideration as I.S. 1893for earthquake resistance and I.S. 875 part-III for wind load on structure. The asumed bearing capacity of soil has been taken as 8 M.T. sqm.1m wide RCC stair case from ground lavel to balcony.M.S. ladder made of 50 X 50 X 6 mm angle section and 20 mm plain M.S. bars (specification of M.S. should be as per IS 800-2007) with hand rails of 20 mm medium class G.I. pipes on both sides in three rows from balcony to top dome resting on an RCC plateform (75 X 75 cm and 10 cm thick) projecting from top ring beam and one alluminium ladder inside the tank body (from manhole to tope domto bootom dome). 6 1 m wide R.C.C. balcony around the tank at the junction point of vertical wall and conical wall.Proper R.C.C. railing and 20 mm dia medium class G.I. pipe (in 3 rows) on both sides of stair case, arround the balcony at each landing from landing with top ring beam upto manhole on the top dome and at the periphery. The G.I. pipes will be supported on R.C.C. postsof 100 mm dia or on the posts made of 50 X 50 X 6 mm M.S. angle section, spaced at intervals not more than 1.5 m.Proper ventilator at top dome in circular shape of 1.2 m dia along with an R.C.C. cover of minimum 1.50 m dia and 7.5 cm thickness, pillar of vintilator should be minimum 50 cm dia. The space between top dome and R.C.C. cover should be covered with mosquito net of standered qualitity along with expended mentaled jail.Electro Megnatic Flow Meter.Lightening conductor as per I.S.S. 2309 of its latest amendments of latest electricity rules. It should consistproper elevation rod with 5 or more fork points proper down conductors of prescribed mental of proper size prescribed by ISS 2309-1969 and ISS 3013-1966.D.I. manhole of min 60 X 60 cm size made of M.S. channel section with adequate cover made of M.S. sheet of minimum 3mm thickness hinged with manhole with locking arrangment. This manhole should be fixe at top dome at proper place.including soil testing from govt institute as per tender document andrelevent IS codes. 7 Zone -1 1300KL/22M 8 Zone -21100KL/25M 9 Zone -3 2400KL/22M 10 Zone -4 300KL/25M 11 CONSTRUCTION OF R.C.C CLEAR WATER RESERVIOUR (C.W.R) CUM PUMP HOUSE OF VARIOUS AT DIFFERENT SITE Design & supply of allmaterial T&P etc and constructRCC CWR cum pump house offollowing capacity with HT, L.T and meter room, GI pipes railling consisting of 3 rows of 20 mm dia G.I pipe and angle iron posts of the dome periphery, S.S ladder from ground level to top of tank and inside the tank, locking device, ventilator, supply and fixing digital level indicator, 25mm PCC 1:2:4 over 80mm PCC 1:4:8 in apron, 150 mm semicircular drain around the tank, two coats of apex paint and testing of tank for water tightness etc. and also including the cost of supply and fixing of all necessary pipes and valves etc all complete as per approved design and drawing.including soil testing from govt institute as per tender document andrelevent IS codes. 12 1200kl (MCWR) 13 Demolition of R.C.C Over Head Tank (OHT)Dismantling of ESRs of various capacities and heights using crane (10 MT capacity) and handing over M.S./ C.I./G.I. pipes, valves, bends, etc. to the Department. However taking steel reinforcement by the dismantling agency and other defung buildings like staff quarters, damaged pump house including removing dismantled materials from site and disposing them at suitable place as directed, etc. complete.Capacity of E.S.R. upto 2 lakh litres and staging upto 12 M heightZone -1 500KL/12M 14 Zone -2 -400KL/12M 15 Raw Water Rising Mains From Intake To WTPExcavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters. 16 500 mm DI K-7(yamuna river to WTP) 17 Supply of ISI mark DI K-7 S&S pipes (push on joints) with supply of allDI specials of following class and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete 18 500 mm DI K-7(yamuna river to WTP) 19 Lowering, laying and jointing with ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position also fixing of pipe on foot over bridge, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. 20 500 mm DI K-7(yamuna river to WTP) 21 Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete. 22 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm 23 -Air valves as per IS 14845 : 2000-100 mm 24 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge. 25 Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 - 500 mm 26 Kinetic Double Air Valves-Air valves as per IS 14845 : 2000-100 mm 27 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 28 Providing reinforcementincluding cutting bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete (including cost of binding wire and MS Bar) 29 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 30 Sluice valve Chamber 500mm 31 Air valve Chambers -Air valves as per IS 14845 : 2000-100 mm 32 Rising MainsSupply of ISI mark DI K-7/K-9 S&S pipes (push on joints) of following with D.I. specials and diameters inclusive of jointing material (Rubber gasket of EPDM Quality IS 12820 / 1989) conforming to IS 8329/2000 for its latest ammendment F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection chacking and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete 33 125 D.I K-9 34 200 D.I K-9 35 350 D.I K-9 36 400 D.I K-9 37 Excavation for pipe line in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters.0 to 1.5 m depth 38 Lowering, laying and jointing with SBR ruber gasketsD.I. K-7/ D.I. K-9 of various classes with DI / MS specials of following diameter in proper position, grade and alignment including conveyance of material to site of work. It also includes cost of jointing materials and rubber rings labour,hydraulic testing etc. complete. 39 125 D.I K-9 40 200 D.I K-9 41 350 D.I K-9 42 400 D.I K-9 43 Supply of following type ofDI valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. completeDouble flanged Ductile Iron Sluice valves as per IS 14840 : 2000./Air valves as per IS 14845 : 2000 including Sluice valve of Isolation 44 125 mm D.I D.F. 45 200 mm D.I D.F. 46 350mm D.I D.F. 47 400 mm D.I D.F. 48 25 mm D.I D.F. 49 50 mm D.I D.F. 50 80 mm D.I D.F. 51 Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as per direction of Engineer-in- charge.Double flanged Ductile Iron Sluice valves as per IS 14840 : 2000 /Air valves as per IS 14845 : 2000 52 125 mm D.I D.F. 53 200 mm D.I D.F. 54 350mm D.I D.F. 55 400 mm D.I D.F. 56 25 mm D.I D.F. 57 50 mm D.I D.F. 58 80 mm D.I D.F. 59 Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design. 60 Sluice valve Chamber (MASONRY TYPE) 61 Air Valve Chamber 62 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 63 MS work in plain RCC incluiding bending supply wastage overlaping etc complete 64 Provision for crossing of Nalas/culvert for laying of pipe line usingsuitable dia. and length 0.60 m more than the outer width of nala, labour, T&P, necessary arrangement for diversion & pumping of water if required, barricading etc required for proper completion of work as per directions of engineer-in-charge.(up to 3.50m wide) 65 NHAI crossing by trenchless technologyProviding and laying of 700 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 400 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply distribution. 66 Railway crossing by trenchless technologyProviding and laying of 250 mm dia MS casing pipe 12 mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU Coating of 500 micron alongwith Providing & Laying of Carrier pipe of dia 125 mm, 8.0 mm thick with outside PU coating of 1000 micron & inside PU Coatingof 500 micron including, providing and fixing of speed restriction caution board as per railway norms and 80 mm. dia GI drain and vent pipe, Providing and fixing the end seal on both ends to plug the annular space between casing and carrier pipe & under ground probe radar survey to check any underground abstruction before finalizing the alignment and to take precautionary measures from power supply. 67 Dismantling of following type of road surfaces for laying of pipe line n work including sorting out of serviceable materials and disposal of unserviceable materials. 68 Bituminious Road 69 Cement Concrete Road 70 Re-instatement of following type of road surfaces after laying of pipe linework including supply of all materials, labour, T&P etc. requuired for proper completion of the work as per direction of engineer-in-charge. The quantity of re-instatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement. 71 Bituminious Road 72 Cement Concrete Road 73 Distribution Network .Supply of ISI Marked or its relevant code HDPE Pipes and Electrofusion specialsof follwing sizes (Dia in mm) with jointing materials, specials of sizes required during constructionas per latest I.S.Samandement upto site of work included loading unloading cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer 74 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 75 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 76 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 77 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 78 Supply of ISI Marked or its relevant code DI K-7 Pipes and Specials of follwing sizes (Dia in mm) with jointing materials, during construction as per latest I.S amendement upto site of work included loading, unloading, cartage insurance, etc all completed but exclusive of GST in various zone as per the drawing and approval to Engineer 79 D.I. K-7/ 200 mm 80 D.I. K-7/ 250 mm 81 D.I. K-7/ 300 mm 82 D.I. K-7/ 350 mm 83 D.I. K-7/ 400 mm 84 D.I. K-7/ 450 mm 85 Supply of following size ofSluice Valves/ Scour Valves,capable for working pressure of 10 kg/cm2 Fire hydrants & Air Valves as per relerelavent I.S.I or its latest amandement. Up to store Including loading, unloading & cartage, taxes duties insurance etc all complete. As per IS: 2906-1969. /Air Valve as per as I.S : 14845D.I. D/F Sluice valve/ Scour valve 86 25 mm. dia DI D/F 87 50 mm. dia DI D/F 88 100 mm. dia DI D/F 89 150 mm. dia DI D/F 90 200 mm. dia DI D/F 91 250 mm. dia DI D/F 92 350mm. dia DI D/F 93 Fire hydrant (80 mm dia.) 94 Excavation for pipe line trenches in Ordinary soil requiring use ofspecialT&P etc. with lift upto 1.5 m lead upto 50 mincluding filling back of excavated earth into trenches and watering ranmming dressing and removal of surpluas earth upto 50.m including supply of alllabour T&P etc complete and as per direction of engineer incharge. 95 Cartage fromstore to site of work for following size (dia in mm)HDPE pipes andElecrofusion Specialsand lowering the same into trenches and laying true to alignment and gradiant including testing of pipe lines cuttings of pipes for making up the length and making joints with electrofusion couplers, bands, tees, endcap etc. with electrofusion machinery including all jointing materials, labour, T&P etc required for proper completion of work. (excluding cost of trenching) 96 HDPE PIPE GRADE PE 100/ PN 6- 90 mm 97 HDPE PIPE GRADE PE 100/ PN 6- 110 mm 98 HDPE PIPE GRADE PE 100/ PN 6- 140 mm 99 HDPE PIPE GRADE PE 100/ PN 6- 160 mm 100 Cartage of DI K-7 pipes and specials of following size (dia in mm) , lowering them into trenches and laying true to alignment and gradiant including testing of pipe line but excluding cost of trenching including all supply of Labour T&P etc complete required for proper completion of work. 101 D.I. K-7/ 200 mm 102 D.I. K-7/ 250 mm 103 D.I. K-7/ 300 mm 104 D.I. K-7/ 350 mm 105 D.I. K-7/ 400 mm 106 D.I. K-7/ 450 mm 107 Carting of following size of Sluice Valves/ Scour Valves Fire hydrants & Air Valves from store to site of work and lowering them into the trenches, fixing in position and jointing them with Pipe line and testing etc including supply of jointing materialand also including supply of all material and construction of suitable P.C.C Support below fittings etc. complete.D.I. D/F Sluice valve/ Scour valve/ air valve 108 25mm dia 109 50 mm dia 110 100 mm dia. 111 150 mm dia. 112 200 mm dia. 113 250 mm dia. 114 350 mm dia. 115 Fire hydrant (80 mm dia.) 116 R.C.C. Thrust block with cement, core sand, and 20mm gauges stone ballast in propotion of 1: 1.5:3 in thrust block of pipe line including reinforcementand its bending the same with 0.08 mm thick binding wire in position and necessary shuttring including proper curing and supply of all materials, labour and T&P etc required for proper completion of work. 117 Thrust Block 118 Supply of all matarial labour T&P etc and constuction of following type of chamber as per type design & drawing & as per diretion of engineer incharge . 119 Sluice valve chamber 120 Scour Valve Chamber 121 Air Valve chamber 122 Fire hydrant chamber 123 Flow Meter chamber 124 Provision for Nala/ Culvert crossing including all materials, labour and T&P etc. complete. It includes supply of D.I. pipe of necessary size for encasing, cement concrete and Brickwork for pillars and any other job for proper completion of work. 125 For crossing ofnalla/culvert upto 3.5 m wide(90mm dia to 110mm dia ) 126 For crossing ofRoad upto3.5 m wide(90mm to 110mm ) 127 For crossing ofRoad upto7.0. m wide(90mm to 110mm) 128 Dismantling of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of labour specials T&P etc. required for proper completion of work 129 Interlocking tile 130 C.C Road 131 Bituminous Road 132 B.O.E Road 133 Reinstatement of following types of roads including sorting out of servicable matarials stacking and disposal of unservicable matarials with in a distance of 50 m. including supply of required new matarials & reinstatement the same includng supply of labour T&P etc. required for proper completion of work. 134 Interlocking tile 135 C.C Road 136 Bitumenous Road 137 B.O.E Road 138 NEW HOUSE CONNECTIONMaking House Connectionwith Distribution main with elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe , including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches , fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. 139 In C.C. Roads 140 For 90 mm to 110mm dia 141 For 125 mm to 160 mm dia 142 For 200 mm to 250 mm dia 143 For 300 mm to 350mm dia 144 For 400 mm to 500mm dia 145 In Bitumenous Roads 146 For 90 mm to 110mm dia 147 For 125 mm to 160 mm dia 148 For 200 mm to 250 mm dia 149 For 300 mm to 350mm dia 150 For 400 mm to 500mm dia 151 In B.O.E. Roads 152 For 90 mm to 110mm dia 153 For 125 mm to 160 mm dia 154 For 200 mm to 250 mm dia 155 In C.C. Interlocking Tiles Roads 156 For 90 mm to 110mm dia 157 For 125 mm to 160 mm dia 158 For 200 mm to 250 mm dia 159 For 300 mm to 350mm dia 160 For 400 mm to 500mm dia 161 In Kacha Roads 162 For 90 mm to 110mm dia 163 For 125 mm to 160 mm dia 164 For 200 mm to 250 mm dia 165 For 300 mm to 350mm dia 166 SHIFTING OF HOUSE CONNECTIONMaking House Connection with Distribution mainwith elecrofusion saddle and fittings ,brass ferrule and Tap ,HDPE /GI pipe ,including Reinstatement of road after Dismantling of road , supply, cartingofspecialsloweringtheminto trenches ,fixing them including bailing out of water necessary excavation for connection including all labour , T&P etc. required for proper completion of the work as per instruction of engineer in charge and tender document. 167 In C.C. Roads 168 For 90 mm to 110mm dia 169 For 125 mm to 160 mm dia 170 For 200 mm to 250 mm dia 171 For 300 mm to 350mm dia 172 For 400 mm to 500mm dia 173 In Bitumenous Roads 174 For 90 mm to 110mm dia 175 For 125 mm to 160 mm dia 176 For 200 mm to 250 mm dia 177 For 300 mm to 350mm dia 178 For 400 mm to 500mm dia 179 In B.O.E. Roads 180 For 90 mm to 110mm dia 181 For 125 mm to 160 mm dia 182 For 200 mm to 250 mm dia 183 In C.C. Interlocking Tiles Roads 184 For 90 mm to 110mm dia 185 For 125 mm to 160 mm dia 186 For 200 mm to 250 mm dia 187 For 300 mm to 350mm dia 188 For 400 mm to 500mm dia 189 In Kacha Roads 190 For 90 mm to 110mm dia 191 For 125 mm to 160 mm dia 192 For 200 mm to 250 mm dia 193 For 300 mm to 350mm dia 194 Building worksSupply of all materials, labour, T& P, complete and construnction of a Half set of One No.Single Roomed staff quarters for Operator staff, pump operator, chaukidaar, pump attendent and other as per approved design in pile Foundation. 195 Zone-1 196 Zone-2 197 Zone-3 198 Zone-4 199 At wtp campus 200 Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation.For Construction of general resedential staff quarters(type-II) 1nos of 2 half set of area 57.70sqm. 201 Supply of all materials, labour, T& P, complete and construnction other as per approved design in pile Foundation for Construction of following type of ancliary buildings Master Control Room(5x4.5x4m) 202 Construnction of Boundary Wall including supply all materials, labour, T&P etc required for proper completion of work as per Approved design in pile foundation. 203 Water Campus Zone 1 204 Water Campus Zone 2 205 Water Campus Zone 3 206 Water Campus Zone 4 207 AT wtp campus 208 Supply and fixing 3.60 M & 1.20 M wide MS Gate with pillars including fabrication and supply of steel and construnction ofboundary pillars etc complete. 209 Provide all materials, labour, T&P etc Required for proper completion of work and construct Interlocking Tiles approach road, laid dry and joints intact with coarse sand mortar including preparation of base etc 210 Water Campus Zone 1 211 Water Campus Zone 2 212 Water Campus Zone 3 213 Water Campus Zone 4 214 Construnction of Drain in Water works Campus30 x 30 cm including labour material and t&p all complete 215 Zone-1 216 Zone-2 217 Zone-3 218 Zone-4 219 Filling of earth of lower portion including levelling and dressing at water works 220 E&M works 221 RAW WATER PUMPING PLANT ATINTAKE WELL 222 Supply of Vertical type oil lubricated statically, dynamically, hydraulicallybalancedturbinepumpcapableofdischargingat980 rpm the following duty condition as given below due to all causes with surface discharge head confirming to IS:1710 and as amended as on date with accessories as per IS 5120/1977(Reconfirmed 2011) and as amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260with 2% NiCi with CF8M impeller running at 980 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer, Suction bell mouth, strainer, oil tube and 24mtr/suitablelengthcolumnassembly,withverticalSolidshaft Squirrel cage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuousratedTEFCIP-55withClassFinsulation,antirotation locking arrengementfor operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 6000 LPM / 35 Mtr. HEAD / 75 HP MOTOR (2w+1s) 223 MAIN PIPING AND VALVES :- 224 Supplyof250 mm dia DIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing . 225 SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67 (IP-68 for field installation),protectionclasssuitableforinstallation inanypositionwithout lubrication, leakage or other operational difficulty with special grease filledgearboxandsuitableformanualoperationforemergency which will automatically dis-engage on restoration of power to motor andwith10wattsinglephasespaceheaterandcontinuouslocal mechanicalpositionindicatorandindividuallyreplaceablecounter gear assembly and with two torque and four limit switches with S.S. flapandoperatedwithgeardrivencamsandofrating250Volt,5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADA operation sluice valve havingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges to be drilled as per IS:1538 Part-IV &VI.Valvesare suitablefor hydrostatictestpressureof10Kg./Cm2forseatand15Kg./Cm2for body(PN-1.0)of following sizes 226 250 mm dia size at Pump delivery 227 350 mm dia size at common header 228 SupplyofDIDF manuallyoperatedsluicevalvehavingBody : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 .Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass 229 Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -3 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 3 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 3 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -1 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot 230 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size 231 Dismantling joint 200 mm dia size at pump delivery 232 Dismantling joint 350 mm dia size at common header 233 Suitable capacity heavy duty handoperatedoverheadTravelling(HOT)crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 234 MOTOR CONTROL CENTER (MCC) PANEL :-Singlefront,Indoor&floormounted,cubicaltypePanelfactory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dust andvermin proof IP-54 /IS:2147, consideredEarth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCB microprocessor baseed(O/C,S/C) release - 1No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital Multifunction Meter- 1 No, Digital Voltmeter 0-500V- 3 No, Digital Amperemeter0-1000A -3Nos,CTFormeterResinCastCL- 1000A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A ,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION200 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 3 No, Spreader Links & Extended ROH for MCCB - 3 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 235 SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offered for operation in AC three Phase 50Hz (+/- 5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ampere meter, Voltmeter, indicating lamp6Nos,LEDON/OFFtypeandStart/Stoppushbuttonand InstrumentFuses,suitabletoSCADAoperationwithRS485Port rating capacity 75 HP / 55 KW 236 Supply & laying of 1.1KV grade XLPE insulated armured multi strand copperconductorcableof3Cx50sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade copper, purity >99.97% ISI marked asper IS:1554 P-I/ IS :7098 P-I) 237 Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm 238 Earthing with GI earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories, and providing masonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 :2018 239 Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) 240 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 241 Supply of CE/UL Certified Surge protector for control panel 242 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & IEC: 60947-6-1) of 400 Amp 243 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. Compact SolarLED Street Light- 60W/12V/27Ah with GI pole 244 Internal & External electrification of Pump house :- 245 Twin tube light covered LED 20 Watt 246 450 mm dia exhaust fan 247 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 248 CompletewiringofPumphouse with1.5 Sqmm& 2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 249 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 250 INSTRUMENTATIONWORKS AT INTAKE WELL 251 Supply of CE/UL Full Bore Electromagnetic Flow Meter of approved makeoffollowing dia and specifications complete: Media : Water (Raw/ Chlorinated), Pressure:upto1.0 MPa,Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SS AISI 316L /Hastelloy C276/Tantalum,LiningMaterial:Hard Rubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard&Rating:ANSI150,Coilhousing:SSAISI304/Carbon Steel/DieCastAluminium, withanticorrosivepaint &provide completelysealed(leakproof)constructionasperrequirement ‘of IEC60529,Accuracy:+0.5%M.V.-velocity0.3to10m/s, Transmitter/signaconvertor Enclosure :DieCast Aluminium, Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable(size - 350 mm dia at common header) 252 SupplyofCE/ULCertifiedpressuretransmitterCEmarkdwith following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 253 Supply of CE/UL cirtified ofRadar level transmitter CE marked with following technical parametersand Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 254 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with CPU and PowerSupplywithanalogandDigitalParameterandfeaturesas specified tostoreandtransmitdataonGSMbackbone,RTU/PLC designedwithlogictotansferdataatmultiplestationsandalso compatible for satellite communication. 255 Control panel with IP 54 Protection, Industrial grade forall equipment and 24V and power supply 256 GSM/GPRS based wirelesscommunicationwith 4G modem for RTU/PLC Capable to transfer and gather data from remotesites to control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM andrecharge 257 CE & UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters 258 CE/UL Certified Intelligent energy meters 259 Complete cabling for instrumentation works with power cabeling to panel of automation 260 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. 261 Installation, testing and comissioning of pumping plant & associated allequipmentsasperapproveddrawingshallbedonebybidder includingchequerredplateandpaintingofpumpingplant&main piping-valves. 262 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 263 CLEAR WATER PUMPING PLANT AT MCWR 264 SupplyofVerticaltypeselfwaterlubricatedstatically,dynamically, hydraulically balanced turbine pump capable of discharging at 1450 rpm thefollowingdutyconditionasgivenbelowduetoallcauseswith surfacedischargeheadconfirmingtoIS:1710andasamendedason datewithaccessoriesasperIS5120/1977(Reconfirmed2011)andas amended thereafter to suit the site condition.The Pump Bowl assembly shall be FG: 260 with 2% NiCi with CF8M impeller running at 1450 rpm., head shaft, SS-410 line shaft , Rubber line shaft bearing , C.I. Bearing retainer,Suctionbellmouth,strainer,oiltubeand05mtr/suitable lengthcolumnassembly,withverticalSolidshaft Squirrelcage induction motor copper wounded and die cast copper rotor (IS:126152011/IEC 60034-1) suitable for the above pump continuous rated TEFC IP-55 with Class F insulation, anti rotation locking arrengement for operation in AC, three Phase/50 HZ (±5%), 415V (±10%), running with a speed of pump.CAPACITY:- 5300 LPM / 50 Mtr. HEAD / 100 HP MOTOR (2w+2s) 265 MAIN PIPING AND VALVES :- 266 SupplyofDIDFSingleDoor/MultiDoorNonreturn/refluxvalve conforming to IS:5312/2003(part I & II) PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing 250 mm 267 SupplyofDIDFsluicevalvewith Electricallyintegratedactuater (Totally enclosed, weather-proof and dust proof construction with IP- 67(IP-68 for field installation),protectionclasssuitableforinstallationinanypositionwithout lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which willautomaticallydis-engageonrestorationofpowertomotorand with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated with positioning card suitable to SCADAoperation sluice valve having Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0)of following sizes :- 268 250 mm dia size at Pump delivery 269 350 mm dia size at common header 270 Supply of DIDFmanually operated sluice valve having body Body : DI GGG 40 / IS 1865 Gr. 400/15, Wedge : DI GGG 40 /IS 1865 Gr. 400/15, Dome : DI GGG 40 / IS 1865 Gr. 400/15, Wedge Nut: Brass / Al. Bronze , Spindle : SS AISI 410 , Seat Rings : LTB IS : 318 Gr. LTB 2,Spindle Nut : LTB IS : 318 Gr. LTB 2 . Valves generally conform to IS:5312.Flanges tobedrilledasperIS:1538Part-IV&VI. Valves aresuitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at By-pass 271 Supply and fabrication of main piping of following sizes350 x 250 x 350 mm MS D/F Tee (10 mm thickness) -4 No250 mm MS D/F Pipe 0.50 mt. (10 mm thickness) - 4 No 250 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 1.00 mt.(10 mm thickness) - 4 No 350 mm MS D/F Pipe 2.00 mt. (10 mm thickness) -2 No 350 mm MS D/F (10 mm thickness) Bend 90o - 2 No 350 mm Blind Flange - 1 NoNecessary G.I. Nut Bolt’s & Rubber Packing - 1 Lot 272 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size 273 Dismantling joint 200 mm dia size at pump delivery 274 Dismantling joint 350 mm dia size at common header 275 3 Ton capacity hand operated over head Travelling (HOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 276 MOTOR CONTROL CENTER (MCC) PANEL :-Single front, Indoor & floor mounted,cubical type Panel factory fabricated(2mmthickforsructure,1.6mmthickfordoor,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coated dustandverminproofIP-54/IS:2147,consideredEarthBus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION400 A, 50KA, TPN, MCCBmicroprocessor baseed(O/C,S/C) release - 1 No,SpreaderLinks&ExtendedROHfor-1No,3PhaseDigital MultifunctionMeter-1No,DigitalVoltmeter0-500V-1No,Digital Amperemeter0-400A -3Nos,CTFormeterResinCastCL- 200A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, ControlMCBSP6A,10KA-3Nos,CTShortingTerminal-4Nos, Neutral Link - 1 No.OUTGOING SECTION250 A, 50KA, TPN, MCCBmicroprocessor based (O/C,S/C) RELEASE - 4 No, Spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 35KA- 2 Nos. Terminal 63A 277 SupplyofAirCooledDigitalsoftstartersuitablefortheLTmotor offeredforoperationinACthreePhase50Hz(+/-5%), 415V(+/-10%) including line contactors suitable for next standard higher KW rating, Over & Under load protection, short circuit & single phasing protection with frequency meter, Ammeter, Voltmeter, indicating lamp 6Nos, LED ON/OFFtypeandStart/StoppushbuttonandInstrumentFuses, suitable to SCADA operation with RS485 Port rating capacity 100 HP / 75 KW 278 Supply & laying of 1.1KV grade XLPE insulatedarmured multi strand copperconductorcableof3Cx95sq.mm fromcontrolPanelto respective Motors with lugs etc. (copper conductor should be electrlytic grade coppe, purity >99.97 % ISI marked as per IS:1554 P-I / IS:7098 P- I) 279 Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm 280 EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 281 Supplyingandlaying50mmX12mmG.I.stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedone by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 282 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 283 Internal & External electrification of Pump house :- 284 Twin tube light covered LED 20 Watt 285 450 mm dia exhaust fan 286 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 287 Complete wiring of Pump house with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 288 Supply of CE/UL Certified Surge protector for control panel 289 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 290 INSTRUMENTATION WORKS 291 SupplyofCE/ULFullBoreElectromagneticFlowMeterofapproved makeoffollowingdiaandspecificationscomplete: Media: Water ( Chlorinated) , Pressure : up to 1.0MPa, Process temp:-50degC, Flow/MeterTube:SS304, Electrode:SSAISI 316L /Hastelloy C276/Tantalum,LiningMaterial:HardRubber/ Neoprene/Poly-urethane(PU) , Flange : SS /CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, withanticorrosivepaint&providecompletely sealed (leakproof) construction as per requirement ‘of IEC 60529, Accuracy:+0.5%M.V.-velocity0.3to10m/s,Transmitter/signa convertorEnclosure: Die CastAluminium,Power Supply : 80-240V AC - 5OHz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category-IP68forsensor(flowtube)andIP67fortransmitter/ convertor, including Surge Arrester, cable, of of following sizes :- 292 350 mm dia. Size at common header of pumping plant 293 350 mm dia. Size at OHT outlet of zone-1 294 350 mm dia. Size at OHT outlet of zone-2 295 450 mm dia. Size at OHT outlet of zone-3 296 200 mm dia. Size at OHT outlet of zone-4 297 Supply of Electrically Motor operated actuator with positioning card and bracketforsluicevalvesuitableforSCADAoperationwithlimit switches, auto de clutch for manual operation in emergency etcas per relevant IS suitable forOHT outlet of following sizes 298 350 mm dia. Size at OHT outlet of zone-1 299 350 mm dia. Size at OHT outlet of zone-2 300 450 mm dia. Size at OHT outlet of zone-3 301 200 mm dia. Size at OHT outlet of zone-4 302 SupplyofD.I./D.F.DismantlingJointsisavariablelengthDouble Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted intotheotherTailpiecewhichallowsthedistancebetweenthetwo flangestobevariedwithincertainlimitsthusprovidingavariable distance piece between two fixed flange end devices like Pumps and Valves.TheDismantlingJointtobesuppliedcompletewithSealing RubberGasketsofEPDMquality(IS:5382/1985Type-4),CastIron Follower Glands andMildSteel (ZincCoated)NutBoltsof Following size 303 Dismantling joint 350 mm dia size at OHT outlet of zone-1 304 Dismantling joint 350 mm dia size OHT outlet of zone-2 305 Dismantling joint 450 mm dia size at OHT outlet of zone-3 306 Dismantling joint 200 mm dia size at OHT outlet of zone-4 307 Supply of CE/UL Certified pressure transmitter CE markd with following technical parametersand Interfacing with PLC panel includingmounting arrangement. Output 4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDAccuracy - +/- 0.1 % of full scale or better Enclosure- IP 68 308 Supply of CE/UL cirtified ofRadarlevel transmitter CE marked with following technical parameters and Interfacing with PLC panel including mounting arrangement.Output-4-20 mA / HART Power supply - 24V DC ext. Display - 4 LEDRange- 0 to …30... mtrsAccuracy - +/- 0.25% of Full Scale or better Enclosure- IP 68 309 CE & UL Certified PLC/ RTU with redundent CPU & power supply in IP 54 enclosure suitable to communicate with GSMBasedmodemwith redundentCPU andPower Supply with analog and Digital Parameter and features as specified for each ZPSto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for CWR. 310 Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 311 GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for CWR & OHT 312 CE & UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 313 CE & UL Certified PLC/ RTU in IP 54 enclosure suitable to communicate with intelligentGSMBasedmodemunit with CPU andPower Supply with analog and Digital Parameter and features as specifiedto store and transmit data on GSM backbone, RTU/PLC designed with logic to tansferdataatmultiplestationsandalsocompatibleforsatellite communication for OHT 314 Control panel with IP 54 Protection , Industrial grade for all equipment and 24V and power supply 315 GSM/GPRS based wireless communication with 4G modem for RTU/PLCCapabletotransferandgatherdatafromremotesitesto control stations all accessories included with signal enhancer, antenna made for pumping plantwith SIM and recharge for OHT 316 CE/UL Certified Intelligent energy meters 317 Complete cabling of instrumentation equipments with power supply of panels for CWR & OHT 318 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessoriesfor pump house, substation and campus. 319 Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done by bidder including chequerred plate and painting of pumping plant & main piping-valves. 320 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 321 11/0.44KV SUB STATION AT INTAKE WELL 322 Supply of star rated Copper wound distribution Transformer ( All the distributiontransformermustbestarratedaspernotificationof (BEE)ministryofpower,GoverenmentofIndia)offollowingrating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cablebox99.6 % & as per IS:1554 P-I / IS :7098 P - (I)from UPPCLmetering panel to H.T. Switch gear panel and panel to transformers 120 Sq.mm. size 326 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. 327 SupplyofH.T.Cableendterminationheatshrinkabletypeoutdoor joint kit 120 sq.mm. 328 Supply & laying of L.T. XLPE insulatedarmoured aluminium conductor cableof1.1KVgradeMaterial:-H4-Gradealuminium conductorofpurity>99.6%&asperIS:1554P-I/IS:7098P- (I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel and main LT panel to MCC panel of 3.5C x 300 Sq.mm. 329 Earthing with copper earth plate 1200 mm X 1200 mm X 12 mm thick includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe of 3 metre long etc.withcharcoal/cokeandsaltasrequiredaccordingtolatest IS:3043 330 Supplying and laying 50 mm X 12 mm G.I.strip at 0.50 metre below groundasstripearthelectrode,includingconnection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done byoverlappingandwith2setsofbrassnutbolt&springwasher spaced at 50mm) 331 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 332 RubbermatsforelectricalpurposeasperIS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 333 NOC from electrical safety Dept. Govt. of UP 334 Fancing of substation in 2mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. 335 Internal & External electrification of HT & LT panel room :- 336 Twin tube light covered LED 20 Watt 337 450 mm dia exhaust fan 338 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 339 CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 340 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro PhosphatebatterywithBISapprovedmake.luminaireshouldbe secondary optic lenses for better distribution with delivered efficacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab.Guaranteefortotalsystemistwoyears.Note:Alltheabove should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. CompactSolarLEDStreetLight- 60W/12V/27Ah with GI pole 341 Supplyofmicroprocessorbasedthreephasesensingpowerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor,lag/leadcapacitorswitchingstatus,alarmoutputforunder current, over current, insufficient compensation, communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 100 KVAR 342 SITC of 01 No. DG Set of Capacity 180 KVA 415+ volt with AMF control Panel cabling,copper earthing etc. complete in all respect.( As per Lataest CPCB- IV Emission Norm ) 343 Installation, testing and commissioning of 11 KV /.44 KV substations includingH.T.panelandL.T.panelincludingchequeredplates,all labour T&P complete in all respect. 344 Testing of DG., Transformer, HT and LT Panel etc at Manufacturer Works 345 11/0.44KV SUB STATION AT MCWR 346 SupplyofstarratedCopperwounddistributionTransformer(Allthe distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (I) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+7.5% to - 15% @ 2.5%) temperature rise of 40 degree C inoil/45degreeCinwinding,ISImarkeddrainvalve,Dialtype Temperature gauge, OTI & WTI, marshalling box, first filling of transformer oil as per IS :335-1953, Epoxy based paint.Rating capacity - 400 KVA (1w+1s) 347 Supply of SCADA Compatible with RS 485 port 11KV,800 A, 25kA / 1 Sec, VCBIndoortypepanelHTboard,freestandingmotoroperated& withdrawaltypefabricatedfrom2mmthickCRCAsheetsteel,With copper busbar, Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRT-CT of required ratio (15VA ; Cl-1.0 / 0.5 ) PT (11 KV /110V/√3) , Fuses , IP42 Protection, 10 / 12-window Annunciation Panel, AC/ DC Control voltage 24/48/ 110/230V , LED Indication lamps , S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection(High oil temperature, Buchholz protection, high winding temperature, power pack 2 x 12 V,etc complete in all respect ready to use(RTU),OEM Must have BIS certificate incuding 1no incoming & 2 no outgoing VCB 348 Singlefront,Indoor&floormounted,cubicaltypeLTPanelfactory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly power coateddust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-Copper Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION800 A, 50KA, TPN, ACB, EDOmicroprocessor baseed(O/C,S/C) release-2No SpreaderLinks&ExtendedROH -2No,3PhaseDigital MultifunctionMeter -1No,DigitalVoltmeter0-500V -1No,Digital Ammeter 0-400A -1No, CT For meter Resin Cast CL-1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC - 1 Set, Control MCB SP 6A,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION400 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2 No, 200 A,50KA,TPN, MCCB microprocessor based (O/C,S/C) RELEASE-2No, spreader Links & Extended ROH for MCCB - 4 Nos., 63A TPN MCCB 32KA- 2 Nos. Terminal 63A 349 Supplyandlayingof11/12KVgradeXLPEinsulatedH.T. armouerd cableasper IS:7098 / II/85,H4- Grade aluminium conductor of purity >99.6 % & as perIS:1554P-I/IS:7098P-(I)fromUPPCL meteringpaneltoH.T. Switch gear panel and panel to transformers 120 Sq.mm. size 350 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. 351 Supply of H.T. Cable end termination heat shrinkable type outdoor joint kit 120 sq.mm. 352 Supply & laying of L.T. XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 300 Sq.mm. (in 2 run for each transformer) 353 Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at WTP of 3.5C x 150 Sq.mm. 354 Supply & laying of L.T.XLPE insulatedarmoured aluminiumconductor cableof1.1KVgradeMaterial:-H4-Gradealuminiumconductorof purity >99.6 % & as per IS:1554 P-I / IS :7098 P-(I),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From Main LT panel to MCC Panel at MCWR of 3.5C x 400 Sq.mm. 355 EarthingwithGIearthplate1200mmX1200mmX12mmthick includingaccessories,andprovidingmasonryenclosurewithcover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043:2018 356 Supplyingandlaying50mmX12mmG.I. stripat0.50metrebelow ground as strip earth electrode, including connection/ terminating with nut,bolt,spring,washeretc.asrequired.(Jointingshallbedoneby overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 357 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 358 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 359 NOC from electrical safety Dept. Govt. of UP 360 Fancing of substation in 2.5mtr height made from MS iron Jali & MS flat, angleironandgroutinginpropermannerasperrelevantIScode including supply and laying of stone grit. 361 Internal & External electrification of Pump house :- 362 Twin tube light covered LED 20 Watt 363 450 mm dia exhaust fan 364 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 60 Watt Flood light 365 CompletewiringofHTandLTroom with1.5Sqmm&2.5Sqmm multistarndcopperconductorwire1.1KVwithrequired5A&15A switches, ceiling rose 366 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay&enclosure(Confirms to IEC:60947-1&IEC: 60947-6-1)of 630 Amp 367 Supplyofmicroprocessorbasedthreephasesensing auto powerfactor correction relay panel , IEC / EN 61000-6- (2&4) having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall have digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current,insufficientcompensation,communicationinterfacewithRS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR rating capacity of 200 KVAR 368 SITC of 01 No. DG Set of Capacity 380 KVA 415+ volt with AMF control Panel cabling, earthing etc. complete in all respect. ( As per Lataest CPCB- IV Emission Norm ) 369 Installation,testingandcommissioningof11KV/.44KVsubstations including H.T. panel and L.T. panel including chequered plates, all labour T&P complete in all respect. 370 Testing of D.G, Transformer, HT and LT Panel etc at Manufacturer Works 371 Automation of DMA 372 Flow Control Valve 373 Supplying, installing ,commissioning & testing of Flow Control Valvefor inlet with flow measuring, flow controlling, pressure monitoringandweb based with cable PLC etc Complete.Pattern Hydraulically operated self actuated flow & level control valve (either with float or altitude pilot) with downstream orifice having Ductile Iron valve body, Y - Pattern, Double Chamber, unitized actuator, Fusion bonded epoxy coating, copper control tubing with Latching Solenoid & Pilot operated as per design, additional speed control feature, drip tight sealing, In-line serviceable, internals stainless steel & protected diaphragm suitable for drinking water. 374 For Zone -1 375 300 mm ( for OHT Inlet) 376 250 mm ( DMA-1) 377 250 mm ( DMA-2) 378 250 mm ( DMA-3) 379 For Zone -2 380 300 mm ( for OHT Inlet) 381 200 mm ( DMA-1) 382 250 mm ( DMA-2) 383 250 mm ( DMA-3) 384 For Zone -3 385 450 mm ( for OHT Inlet) 386 300 mm ( DMA-1) 387 400 mm ( DMA-2) 388 300 mm ( DMA-3) 389 For Zone -4 390 100 mm ( for OHT Inlet) 391 200 mm ( DMA-1) 392 IsolationValve 393 Supplying, installing ,commissioning & testing of DI Isolationvalve with electric acuator for isolation of DMA flow controling with cable PLC etc Complete. 394 For Zone -1 395 250 mm ( DMA-1) 396 250 mm ( DMA-2) 397 250 mm ( DMA-3) 398 For Zone -2 399 200 mm ( DMA-1) 400 250 mm ( DMA-2) 401 250 mm ( DMA-3) 402 For Zone -3 403 300 mm ( DMA-1) 404 400 mm ( DMA-2) 405 300 mm ( DMA-3) 406 For Zone -4 407 200 mm ( DMA-1) 408 Pressure Transmitter 409 Supplying, installing ,commissioning & testing of CE/UL Certified Pressure Transmitterfor pressure monitoring web based with cable PLC etc Complete for all 10 DMA,s of All 4 Zones 410 Electromagnetic Flow Meter 411 Supplying, installing ,commissioning & testing of CE/UL Certified Electromagnetic Flow Meterfor Flow monitoringweb based with cable PLC etc Complete 412 For Zone -1 413 250 mm ( DMA-1) 414 250 mm ( DMA-2) 415 250 mm ( DMA-3) 416 For Zone -2 417 200 mm ( DMA-1) 418 250 mm ( DMA-2) 419 250 mm ( DMA-3) 420 For Zone -3 421 300 mm ( DMA-1) 422 400 mm ( DMA-2) 423 300 mm ( DMA-3) 424 For Zone -4 425 200 mm ( DMA-1) 426 Residual Chlorine Analyser 427 SITC of Chlorine Analyser with MODBUS RTU having Following specification - (a) FRC senser range 0-5 ppm (b) Analyser with RS 485 O/P suitable to OHT distribution line and compatible with SCADA system toofor all 10 DMA,s of All 4 Zones 428 Chlorine Dozer For DMA 429 SITC of SCADA Compatible Chlorination Systemfor all 10 DMA,s of All 4 Zones 430 SCADA For DMA 431 CE & UL Certified PLC/RTUin IP 54 enclosure suitable to Communicate with GSM based modem unit with CPU & Powersupply with annlog & digital parameter & featuers as specified, for each DMA to store and transmit dataon GSM backbone, RTU/PLC desgined with logic to transfer data at multiple stations with control panel as specified intender technical specifications. 432 G.S.M./G.P.R.S. based wireless communication with 4G modem for RTU/PLC Capable to transfer & gather data from remote sites to control stations all accessories include with signal enhancer antenna made for pumping plant internetcharges as specified in tender technical specification . 433 Intelligent energy meters 434 Control Panel with IP 54 Protection, Industrial Grade for all equipment. (Separate for control (24 V) and power equipments.) upto 3 pumps. 435 CE/ UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters. 436 CE/UL Certified 1 KVA UPS with Batteries for data backup. 437 CE/UL Certified 10 KVA UPS with Batteries for valve operation of each OHT . 438 Cabling 439 Complete Cabling for Intake well including all power & control cable of all equipments at ZPS and OHT. 440 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories . 441 MASTER CONTROL STATION (MCS) AT WTP 442 CE/UL & BIS Certified industrial grade LED MONITOR with latestconfiguration as per specification 65 443 Video call media player of same OEM 444 Core i7 10th gen Desktop/ laptop with 32 GB RAM and 256 GB SSD + 1TB HDD 445 CE/UL Certified 5 KVA UPS with Batteries required for mentioned work wih 01 hrs backup 446 Full Development version of TAGS SCADA software with costomization of software for MCS for unlimited digital and analog Input / output features as per requirements 447 CE/ULcertifiedmastercontrolroomPLCwithredundantCPU&power supply at MCS in IP-54 enclosure as per site requirement and specification required to complete in all respect 448 CE/UL certified Field gateway agent for transfering data forMCS/control room 449 GSM/GPRSbasedwireless/Broadband/equivelentcommunicationsystem for PLC Capable to transfer and receive data & gather data from remote sitestocontrolstationsallaccessoriesincludedwithsignalenhancer,antenna along with running expences 450 CE/UL certified Firewall for network protection 451 CE/UL Certified Surge protector for Ethernet communication protection 452 CE/UL Certified industrial grade Ethernet switch 453 Mobile app facility system architecture (industries internet based & viewed through mobile apps for increasedblocal & remote visibility) 454 Canon/HP or equivalent Laser Printer 1018 or equivalent. 455 Hp or equivalent multifunctioning Laser Printer with scanner 456 BEE : 5 Star rating 1.5 Ton capacity air conditioner with voltage satbilizer 457 Office furniture ( office table - 2 No, revolving chair- 2No, Office chair-3 No, Godrej almirah - 1No) 458 SecuritySurvelliance IP 4.0 MP HD Bullet Guard + AudioCamerawith NVR 2 SATA, 2 TB HDD, HDMI cable, CAT 6 cable etc allrequiredaccessories. 459 Installation, Commissioning and testing of all above equipments for MCS with all power cables 460 TRAIL & RUN FOR 3 MONTHS WITHOUT ELECTRICITY CHARGES
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
36.
Housing Urban and Rular Development #9502542 Technical Bid
Tender For Electrical Work At Thdc Singrauli . - INTERNAL WIRING 2 Point wiring in PVC conduit, with modular type switch :- 3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 4 Group C 5 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 6 Group C 7 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 8 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 9 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 10 Circuit / Sub main wiring in PVC conduit :- 11 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 12 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 13 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. 14 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire 15 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire 16 S/F light plug point Modular Type Accessories :- 17 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 18 S/F power plug point modular Type Accessories :- 19 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 20 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 21 DISTRIBUTION BOARDS & MCBs 22 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 23 Single pole 24 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 25 Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 26 6 Way (4 + 18), Double Door 27 8 Way (4 + 24), Double Door 28 Supplying and fixing following way, Single Pole and Neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 29 8 way , Double door 30 12 way , Double door 31 S/F DP MCB Isolator 32 Supplying and fixing following Rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 33 40 Amps 34 S/F 4P MCB Isolator 35 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 36 63 Amps 37 S/F DP (RCCB) 38 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 39 40 Amps 40 TELEPHONE, TELEVISION & DATA SYSTEM (socket,wiring & conduting only) 41 S/F MODULAR BOXES, BASE & COVER PLATE :- 42 Supplying and Fixing Following Size/ Modules, GI Box Alongwith Modular Base & Cover Plate for Modular Switches in Recess etc. as Required. 43 1 or 2 Module (75 mm x 75 mm) 44 S/F MODULAR TYPE SWITCH / SOCKET :- 45 Supplying and Fixing Following Modular Switch/ Socket on The Existing Modular plate & Switch Box including connections But Excluding Modular Plate etc. as required. 46 Telephone Socket outlet. 47 TV Antenna socket outlet. 48 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 49 25 mm. 50 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, Unarmored Telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 51 2 Pair 52 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 54 1 run of cable 55 LIGHTINGFIXTURESANDFANS 56 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 57 Installation, testing and commissioning of pre-wired, fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as Required. 58 Installation of Exhaust fan in the existing opening, including making good the damage, Connection, Testing, Commissioning etc. as Required. 59 Upto 450 mm sweep 60 Fixing Louvers / Shutters for Exhaust Fan: 61 Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes. 62 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing 63 CABLE & ACCESSORIES 64 LT CABLE LAYING 65 Laying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV Grade of Following Size Direct in Ground Including Excavation, Sand Cushioning, Protective Covering and Refilling the Trench etc. as required. 66 Upto 35 sq. mm 67 Above 35 sq. mm and upto 95 sq. mm 68 Above 95 sq. mm and upto 185 sq. mm 69 Above 185 sq. mm and upto 400 sq. mm 70 LT CABLE JOINTING & END TERMINATION 71 Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 72 3½ X 25 sq. mm (28mm) 73 3½ X 35 sq. mm (32mm) 74 3½ X 50 sq. mm (35mm) 75 3½ X 95 sq. mm (45mm) 76 3½ X 120 sq. mm (45mm) 77 3½ X 150 sq. mm (50mm) 78 3½ X 185 sq. mm (57mm) 79 3½ X 240 sq. mm (62mm) 80 MISCELLANEOUS ITEMS 81 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 82 EARTHING 83 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. 84 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.. (NEUTRAL EARTHING) 85 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 86 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 87 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 88 11KV HT Board, 250 KVA Transformer, 200 KVA DG Set, HT Cable & Accessories 89 H V CABLE LAYING 90 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 91 Above 120 sq. mm and upto 400 sq. mm 92 Supply and making Indoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 93 3 C x 240 Sq.mm 94 Supply and making Outdoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 95 3 C x 240 Sq.mm 96 Supply and Making Straight Through Cable Jointing With Cast Resin Compund, Including Ferrule & Other Jointing Materials for Following Size of 3 core, XLPE Aluminium conductor cable of 11KV grade as required. 97 3 C x 240 Sq.mm 98 RCC Hume pipes 99 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 250 mm dia 101 300 mm dia 102 100 mm dia 103 Manholes 104 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. 105 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 106 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 107 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 108 HDPE PIPES 109 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 110 200 mm dia (OD-200 mm & ID-175 mm nominal) 111 CABLE TRAYS 112 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 113 150 mm width X 50 mm depth X 1.6 mm thickness 114 300 mm width X 50 mm depth X 1.6 mm thickness 115 450 mm width X 50 mm depth X 2.0 mm thickness 116 600 mm width X 50 mm depth X 2.0 mm thickness 117 EXTERNAL LIGHTING 118 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 119 Above 4.5 metre and upto 6.5 metre 120 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape , Hole Seeling to be done complete as required. 121 32 mm dia 122 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. 123 Upto 35 sq. mm 124 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 125 Upto 35 sq. mm 126 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 127 3 core 2.5 sq.mm (for6/4 Mtr Poles) 128 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 129 63 mm dia (OD-63 mm & ID-51 mm nominal) 130 TELEPHONE, TELEVISION & DATA SYSTEM (socket,wiring & conduting only) 131 Supplying & Fixing Modular Type Computer jack RJ 45 ISI mark 1 Module on existing Mounting plate and box Complete with all accessories as required. 132 Light Fixtures and Fans 133 Supply of 40W LED Recessed Light Fixture Aesthetically designed 2x2 LED Flat panel light which provides soft-light and glare free symmetrical illumination complete with all accessories as required. 134 Supply of Surface Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 135 Supply of Recess Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 136 Supply of Recess Mounted Energy Efficient, LED Luminaires18W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 137 Supply, of Linear & Compact 10W Mirror Light with Decorative Grey Caps, Polycarbonate Body & Ribbed Opal Diffuser. 138 Supply of LED LuminairesBATTEN20W LED Tube Light of Box Type Prewired Indoor Luminairewith Energy Efficient Electronic Ballast, with End Caps Complete as Required. 139 Supply of Bulk Head Luminaire, heat resistant Glass cover suitable for 10W to 15W LED complete as Required. 140 Supply of Following sweep exhaust fan with guard suitable operation on single phase 230 V, 50Hz. AC Supply, with lowers /shutters in the existing opening. 141 300 mm Sweep 900 rpm 142 Supply & Fixing of 400mm Wall Mounted Fan with all accesseries as required complete for installation. 143 DISTRIBUTION PANELS 144 MAIN LT PANEL 145 NOTE:- MCCBs Wherever Specified shall have Rotary Handle. 146 Suppy , installation, testing, Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioningof2mm CRCA sheet steel fabricated cubical type Main L.T. Panel (Totally Type Test Assembled - TTA) floor mounting, dust & vermin proof, front operatedconstruction, enclosure class - IP 52,As per IEC 61439 after proper treatment with 9 tank process with top/bottomremovable gland plates, as required, double compression type cableglands,earth bus, hinged and lockable doorsto achieve dust and vermin proofcomplete with all inter connectionssmall wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc.The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable as required. Panel Should Be Internal Arc tested at 50ka for .3 sec as per IEC61641. 147 (Under no case temperature of main LT panel shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). 148 Degree of protection IP-42 149 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCBs. 150 Colour: Siemens Gray Powder Coated or as per approved shade. 151 INCOMER 1 FROM 250 KVA OUTDOOR TRANSFORMER 152 1 Nos. 400 amps four pole MCCB of fault breaking capacity 50 KA (Ics=Icu)fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicator and frame earthing contact ,confiming to IS 13947-21993 as amended upto date complete with following Accessories. 153 1 set of 3 CTs of ratio 400/5A, Class 1.0 accuracy 15 VA burden for APFCR. 154 Independent manual spring closing mechanism - 1 No. 155 Microprocessor release (EMI and EMC certified) for over current, earth fault and short circuit protection - 1Set . 156 Multifunction meter with selector switch with suitable CTs and back up MCBs. 157 3Nos. Phase indicatingLED lamps with 2 Amp backup MCB, breaker ON/OFF/Trip indication light with 2A MCB , test terminal block set, MCB , circuits as per standatd practice , auxiallry contact for positive interlocking of the breakers as required. 158 Shunt trip coil 220 Volt AC. 159 INCOMER FROM DG SET (200 KVA) - 1 Nos 160 1 Nos. 400 amps four pole MCCB of fault breaking capacity 50 KA (Ics=Icu)fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicator and frame earthing contact ,confiming to IS 13947-21993 as amended upto date complete with following Accessories . 161 1 set of 3 CTs of ratio 400/5A, Class 1.0 162 Independent manual spring closing mechanism - 1 No. 163 Microprocessor release (EMI and EMC certified) for over current, earth fault and short circuit protection- 1Set . 164 Multifunction meter with selector switch with suitable CTs and back up MCBs. 165 Protection releaseswith LSIG and Over voltage ,under voltage,Reverse power protection Relay & Metering & Accessories for each D G set incomers 166 3 Nos. Phase indicatingLED lamps with 2 Amp backup MCB, breaker ON/OFF/Trip indication light with 2A MCB , test terminal block set, MCB , circuits as per standatd practice , auxiallry contact for positive interlocking of the breakers as required . 167 Shunt trip coil 220 Volt AC. 168 1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (200 KVA) 169 INTERLOCKING 170 Interlocking logic electrical Interlocking betweenincomers and bus coupler and it should have auto start and auto trip facility for Automatic Operation of The Breakers Wit Manual Over Rid Facility 171 BUS COUPLER 172 One Number 400A 50KA 4 poleMCCB as Bus Coupler with ON/OFF Indication. 173 BUS BAR 174 500 A TPN Aluminium bus bar with heat Shrink Sleeve 175 OUTGOINGs 176 All the MCCBs Shall be Equiped/Provided with all accessories & Inbuid protection releas & MCCBs Shall be Thermal Magnetic upto 250A & Above Microprocessor Based with inbuiltO/L & S/C release. 177 1 Nos. 200 AMPSTP MCCB (Capacitor Panel) 178 1 No. 125A 36KA4P MCCB. (Ground Floor Panel) 179 1 No. 125A 36KA4P MCCB. (First Floor Panel) 180 1 No. 125A 36KA4P MCCB. (UPS Panel) 181 1 No. 100A 36KA 4P MCCB (Lift Panel) 182 1 No. 100A 36KA 4P MCCB (Fire Fighting) 183 1 No. 100A 36KA 4P MCCB (Plumbing) 184 1 No. 125A 36KA4P MCCB. (External Lighting) 185 2 No. 125A 36KA4P MCCB (Spare) 186 2 No. 100A 36KA4P MCCB (Spare) 187 Other items such as 188 1 set of control wiring 189 1 Set of designation plates 190 NOTE :- Adequate Quantity of Fire Suppression system with Pneumatic gas cylinder and Heat Sensitive Pneumatic tubing to be used in panel as perthe current fire norms & SURGE PROTECTION DEVICES Type 1 ( Class B), 4 Mode, spar type suitable for 10/350µs surge,3Nos. phase to earth and 1Nos. neutral to earth with impulse Current Iimp. ≥ 50KA Per mode & In ≥ 25kA per Mode. 191 Complete Panel as Above and complete 192 AUTOMATICPOWERFACTORCORRECTIONPANEL(CAPACITOR PANEL) - 90 KVAR- INNOVATION CENTER BLOCK 193 Supplying, Installation, Testing and Commissioning of cubicle type capacitior panel suitable for 415 & 3 phase 50 HZ A.C. supply System fabricated in compartmentalised design from CRCA Sheet Steel of2 mm thick for frame work and cover, 3 mm thick for gland plates i/cpowder coating in approve shade having 500 AMP capacityTPN Aluminium bus bar DMC/SMC bus bar supprot entire pannel should have common Al. earth bar for size 50 mm x 5 mm i/c Providing & fixing following switch gear mounting there on fans,grills for propor ventillation complete with gaskets & inner connection i/c connection with existing CTS in the main CT Panel complete as reqd. The panel board shall be of dust and verm proof with degree of protection IP 42) 194 a) 200 Amps TP MCCB with Microprocessor Based release and E/F proctection with time dely(Ics=100% Icu) - 1 No. 195 b) 250A, 4 strip Tinned Aluminium busbar -1 Set 196 c) Micro processor based automatic Power factor control relay i/c power factor metre in 8 steps 197 d) Multi functional meters with suitable CTS and protection MCBS 1 set. 198 e) 3 Nos. Phase indieating right (lamp) with MCBs protection. 199 OUTGOINGS- 200 1 Set - 63 Amp TP MCB 10 KA and Capacitor duly switching contactor for 20 KVAR capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with protection MCB & delay timer complete i/c 20 KVAR mixed dielectric with 7% detuned filter copper reactor type capacitor bank with inter Connection 201 7 Set - 40 Amp TP MCB 10 KA and Capacitor duly switching contactor for 10 KVAR capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with protection MCB & delay timer complete i/c 10 KVAR mixed dielectric with 7% detuned filter copper reactor type capacitor bank with inter Connection 202 complete panel as above and complete 203 GROUND & FIRST FLOOR PANEL (TYPICAL) 204 SITC of cubicle LT pannel suitable for 415V, 3 phase, 4 wire 50 HZ Ac supply system, fabricated in conmpartmentalized (preferbly) design from CRCA sheet of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bar supports, , bottom base channel of MS section not less than 50mm x 50mm x 5mm thick,entire pannel shall have a common copper earth bar 25mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AI. bus bars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conducter S/C cable, cable alleys, cable gland plates in two half. i/c providing following switch gears :- 205 INCOMER : 125 AMP 36KA FP MCCB 206 BUS BAR :160 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. 207 OUT GOINGS: 208 63 AMP 4P MCB Including 1 no. of Indication Lamp (DBs) - 6 209 63 AMP 4P MCB with1 no. of Indication Lamp (Spare) - 2 210 40 AMP DP MCB with1 no. of Indication Lamp (Spare) - 1 211 complete panel as above and complete 212 UPS PANEL 213 SITC of cubicle LT pannel suitable for 415V, 3 phase, 4 wire 50 HZ Ac supply system, fabricated in conmpartmentalized (preferbly) design from CRCA sheet of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bar supports, , bottom base channel of MS section not less than 50mm x 50mm x 5mm thick,entire pannel shall have a common copper earth bar 25mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AI. bus bars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conducter S/C cable, cable alleys, cable gland plates in two half. i/c providing following switch gears :- 214 INCOMER : 160 AMP 25KA FP MCCB (Including BY Pass Switch for 50 KVA UPS) 215 BY PASS Switch for UPS 160 AMP FP- 1 no. 216 BUS BAR :200 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. 217 OUT GOINGS: 218 63 AMP 4P MCB Including 1 no. of Indication Lamp (DBs) - 7 219 40 AMP DP MCB Including 1 no. of Indication Lamp (DBs) - 2 220 63 AMP 4P MCB Including 1 no. of Indication Lamp - 2 221 100 AMP 4P MCCB Including 1 no. of Indication Lamp - 1 222 63 AMP 4P MCB with1 no. of Indication Lamp (Spare) - 1 223 40 AMP DP MCB with1 no. of Indication Lamp (Spare) - 2 224 complete panel as above and complete 225 LIFT PANEL 226 Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out ofCRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ completewith aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid. 227 INCOMER :100 AMP FP MCCB 228 BUS BAR : 125 AMP, 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp. 229 The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature. 230 OUT GOINGS: 231 1 No 63 AMP 4P MCB(Lift) 232 1 No 40 AMP DP MCB(Machine Room DB) 233 1 No 40 AMP DP MCB(Spare) 234 1 No 63 AMP 4P MCB(Spare) 235 complete panel as above and complete 236 EXTERNAL LIGHT FEEDER PILLAR 237 Design,Manufacture, Supply, Installation,Testing and CommissioningofPanelFabricated out of 16 SWG CRCA sheet steel,IP 54, wall / floor mounting type with rain canopyThe sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands,including connection with outgoing feeders completeinall respect, Panel Should Have Double Earthing Provision Which Connected to the Nearest Earth Grid. 238 INCOMER: 239 1 no. 125A, 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with Selector Switch, Matching Cast Resin CTs. + 3 Nos 63A DP MCB For each Phase.with 3 Nos Astronomical Weekly programmabletime switch (SST- 1min) ON Phase for automaitc switching of landscape light fixtures at sun set and sun rise or twilight (auto on/ auto off and auto mode) with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site. 240 BUS BAR 241 TPN Aluminium bus bar with heat Shrink Sleeve rated for 125A. 242 OUTGOING 243 18 nos 16A DP MCB 244 2 nos 40A DP MCB 245 1 nos 40A 4P MCB (SPARE) 246 Other items such as 247 1 Set of control wiring 248 1 Set of designation plates 249 All Items complete as above 250 CABLE & ACCESSORIES 251 Supplying of Following Sizes of 1.1 KV Grade MulticoreAluminium Conductor XLPE Power Cable Insulated armoured cable conforming to IS:7098 (Part - I) or as per Relevant IS Code complete with all Amendments etcand should be NABL certified as required. 252 3.5 C X 240 Sq.mm Al. XLPE arm. 253 3.5 C X 185 Sq.mm Al. XLPE arm. 254 3.5 C X 150 Sq.mm Al. XLPE arm. 255 3.5 C X 120 Sq.mm Al. XLPE arm. 256 3.5 C X 95 Sq.mm Al. XLPE arm. 257 3.5 C X 50 Sq.mm Al. XLPE arm. 258 3.5 C X 35 Sq.mm Al. XLPE arm. 259 3.5 C X 25 Sq.mm Al. XLPE arm. 260 MISCELLANEOUS ITEMS 261 SITC of CO2 Fire Extinguishers 4.5 kg capacity complete in all respect ISI : 15683 marked. As per Safety plus extinguisher fire carbondioxide 4.5kg, duly charged, portable and complete as per defence specification (safetyplus SPEC 4.5) 262 UPS 263 UNINTERRUPTED POWER SUPPLY (UPS) - 50 KVA 264 Supply of 50 Kva Online UPS, IGBT UPS(Transformer-less Design). 265 Supply of SMF Batteries (12Volt VRLA, 120 Ah, 28 Numbersto provide 30 Min Backup in total for 50 kva UPS at 0.8PF and ECV=1.7V. 266 Fully rated Inbuilt static switch at the inverter output and 100% rated Inbuilt static switch at the static bypass line integrated in UPS module. 267 Supply of Local Accessories (like Cabling Between UPS and the Battery onsidering Cable Routing ,Battery Interlinks , Battery Rack etc). 268 Backfeed protection at Mains & Bypass (Inbuilt / External). 269 Installation and Commissioning of 50 kVA UPS, Battery and Accessories. 270 Supply , installation , testing and commissioning 160A FP MCCB of25KA breaking Capacity in metal sheet enclosure with ON/OFF, TYB Indication lamps for Incoming of UPSComplete in All Respect as Required. 271 SUB STATION - 11KV HT BOARD, 250 KVA TRANSFORMER, 200 KVA DG SET, HT CABLE & ACCESSORIES 272 11KV SINGLE VCB PANEL BOARD 273 11KV SINGLE PANEL HT VCB (Indoor Type) - ONE INCOMERS CUM OUTGOING 274 Design, Manufacture and Supply of 1 Panel, 11 kV HT VCB Switch Board with Following Accessories : 275 Incoming Cum Outgoing 276 Indoor Type - 630A, 11kV, 350MVA for 3 Sec., TP, Horizontally isolated, horizontally drawout type, motorised spring charged, closing mechanism, motor voltage 230V AC, shunt tripping & Closing coil Voltage 24V DC, Electrically Operated, Trip Free, Dust & Vermin Proof, Vacuum Circuit Breaker (VCB) With Mechanical & Electrical OFF/ON Indicators & Provided with Following -1 No. 277 CT chamber with double wound single phase, cast resin CT, 15VA burden with core-1 for metering (CL-1) and core-2 for protection (CL-5P10) and of 60/5/5A ratio - 3Nos. 278 IDMT relay with 3 elements for over current (50-200%) and 1 element for earth fault protection(10-40%). - 1 Set 279 Anti Pumping Relay - 1 Set. 280 Master Trip Relay - 1 Set. 281 Trip circuit supervision relay - 1 Set. 282 Potential Transformers, 3 Phase, 3 Limb,Drawout Type, Resin Cast 11000/(Root 3)/110/(Root 3) Ratio Class 1 Accuracy, 100 VA Burden, with HV fuse on primary side and MCB/ MPCB on secondary side. - 1 Set 283 6 Windows Annunciator with Hooter - 1 Set 284 1 Window for over current trip - 1 Set 285 1 Window for earth fault trip - 1 Set 286 1 Window for master trip relay - 1 Set 287 1 Window for Emergency Stop Push Button - 1 Set 288 2 Windows Spare - 1 Set 289 Digital Ammeter with inbuilt selector switch - 1 Set 290 Digital Voltmeter with inbuilt selector switch - 1 Set 291 A set of breaker ON/OFF/Trip/DC control supply healthy/Trip circuit healthy/ Spring Charged VCB in test / VCB in service & R,Y,B phase indication lamps. - 1 Set 292 Emergency stop push button -1 Set 293 Limit switches with 6 NO/ 6 NC breaker auxiliary contacts - 1 Set 294 Control:- T-N-C (Trip, Neutral, Close) breaker control switch with indication arrangement. - 1 Set 295 All control wiring with protection & test terminal block as required. - 1 Set 296 Space heater with thermostat for moisture absorption. - 1 Set 297 Suitable for connection to 3C x 240 sq.mm. Cross linked polythelene(XLPE) 11kV cables or as called for. - 1 Set 298 Cable box for 3C x 240 sq.mm 11kV XLPE Al. conductor cable. - 1 Set 299 HT Danger Plate - 2 Set 300 Incoming as described above. 1 Sets 301 Powerpack as Required to Be Included (220V/24V DC), 7AH Battery for Each Breaker Module. 302 SINGLE PANEL 11KV HT VCB PANEL AS DESCRIBED ABOVE 303 11KV TRANSFORMER(11 KV /0.433 KV) (250 KVA) 304 11KV TRANSFORMER(11 KV /433 V) (250 KVA) 305 Supply Installtion, Testing and commissioning of outdoorOil cooled Outdoor Type Transformer11 KV/433 Volt Rating 3 phase, Double Wound with copper Winding.(as per IS : 1180 (part 1) : 2014Level 2 (AMENDMENT 4)/ Equivalent IEC Standard , OLTCin Steps (+10% to -10% @ 1.25%), Insulation Class : Class A , Temperature Rise : 40 Deg.c in Oil , 45 deg.c by Resistance, 50 deg.c by Ambient , Dyn 11 Vector Group and other Standard Accessories as Required Including Followings : 306 PLEASE NOTE THE TRASNFOREMR SHALL BE IN COMPLINACE WITH NEW REGUALTION IS 1180 or Equivalent IEC Standard FOR LOSSES AND EFFICIENCY and ammended upto date 307 Civil work shall be paid extra as per actual. 308 Cable Termination box with disconnecting facility for 11 KV 3C-240 sq mm XLPE cable at 11 KV side 309 ON Load Tap Changer on HV side+10% to -10% @ 1.25%. 310 Standard Fittings , Accessories /Spares :- 311 Rating and Terminal Marking Plate - 1 312 Earthing Terminals - 2 313 Lifting Lugs - 2 314 Drain Valve with Blanking Plate - 1 315 Filter Valve with Blanking Plate - 1 316 Conservator - 1 317 Conservator Oil Filling Hole With Cap - 1 318 Oil Level Indicator with Min. Marking - 1 319 Dehydrating Breather - 1 320 Conservator Drain Plug - 1 321 Air Release Device - 1 322 Pressure Relief Valve - 1 323 Thermometer Pocket - 1 324 Rollers uni directional - 4 325 Radiators Detachable - 4 326 HV Cable Box- 1 327 LT Cable Box - 1 328 Seperate Neutral Terminal - 1 329 ON Load Tap Changer - 1 330 OTI with alarm and trip contacts 331 Buchholz relay with alarm & trip contact 332 Current Transformer 333 Radiator Valve 334 Marshalling Box 335 WTI with alarm & trip contact 336 WTI Pocket 337 Drain Valve with Blanking Plate (OLTC) 338 Filter Valve with Blanking Plate (OLTC) 339 OLTC Surge Relay 340 RTCC Indoor 341 AVR 342 250 KVA (11/433V) AS DESCRIBE ABOVE 343 DIESEL GENERATOR SET - 200 KVA DG SET :- 344 200 KVA DG SET 345 Supply, intastallation, Testing & Commissioning of200 KVA Capacity Radiator cooled DG Set with Suitable StandardAMF Panel & suitable capacity engine directly coupled withalternator for 415 volt, 3 phase, 50 Hz, 4 wire, Generation system complete with accessories, Fuel Oil Tank & Control Panel etc as Required and sound proof acquastic enclosurefor the DG SET (75 db @ 1m) , including supply,fixing of antivibration pads suitable for 200 KVA DG Set as per standards of Engine manufacture, provision of conrol cablefrom engine to control panelto engine. Provision of pipe fuel pipe line of suitable size from fuel tank to engine and over flow pipe engineto fuel tank complete gatevalve and fitting leader maker etc. Supply , Intallation of starting batteries of suitableAH as recommended by manufacterer Heavy duty complete as required at site complete with stand and battery charger residentials silencer sutaible for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all as required and as directed by Engineer Incharge. 346 Diesel Engine (CPCB-4 NORMS COMPLANT) 4 Stroke, Radiator Cooled, Diesel Engine Model Developing Output Prime 160 KW Having Following Arrangement :- 347 Flywheel With Starter Ring for Generating Set 348 Air Filter , Lube Oil Cooler Assembly with Accessories. 349 Exhaust Air Manifold 350 Exhaust Bellow 351 Fuel Fiter 352 Diesel engine pre heating arrangement 353 Lube Oil Filter 354 Exhaust Gas Turbo Charger with After Coller 355 Day Tank For fuel with Markings 356 ECP Panel mounted on a Separate Frame. 357 Radiator with Pusher Type Fan, With Fan Guard, Coolant Pump. 358 12V Electrical Starting System with Starter Motor and Battery Charging Alternator. 359 Engine Mounting Supports 360 ALTERNATOR Rated at 200 KVA, 415 Volts, 3 Phase, 4 Wire, 0.8 P.F (lag), 50HZ, 1500 RPM, IN Accordance with IS 4722 /IEC 60034 as per following Specification. 361 Rating: Suitable for an over-load of 10% for 1 hour in every 12 hours operation. 362 Voltage Regulation: Provided with Fast Response Thyristor Type Electronic automatic voltage regulator, which holds output voltage within desired limits. (+/- 1%). 363 Excitation: Self Excited - Self Regulated. 364 Alternator Loading: Suitable for Taking Rated load Immediately After Machine Reaches Rated Voltage and Speed. 365 Vibration: Suitable for Direct Coupling with Engine and Mounted on Common M.S. Channel Base Frame. 366 Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. 367 Cooling: Air Cooled type with radial fan mounted on Rotor. 368 Winding and Insulation: Insulation class H as defined in IEC – 60034-1 369 ACCESSORIES :- 370 MS Base Frame Suitable for Mounting of the Offered Engine and Alternator. 371 Day Fuel Tank of Standard Capacity as per Rating Complete Fuel Gauge, Inlet/Outlet Connections, Drains Plug, Etc. 372 Residential Silencer (1.5 Meter with 750 mm diaApprox) Including Insulation of Silencer. 373 2 Nos 12 Volts DC Battery of Suitable Capacity with Leads. 374 1 Set of AVM Pads Fitted in Base Frame. 375 TOTAL FOR 200 KVA DG SET 376 Supply of H.T. Cable 377 Supply & Testing of following 11 KV (E) grade multicore Aluminium conductor XLPE insulated cable, insulation screening withextruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required. 378 3 C x 240 Sq. mm11 KV (E) 379 Supply , Installation, Testing & Commissioning of Integrated Post Top Lantern With 40W LED Lampincluding Pole &connection with 3 x 2.5 sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. 380 Supply , Installation, Testing & Commissioning of 50 W LED withcomplete with pot optic reflector connection with 3x2.5sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. 381 Supply, Installation, Testing and Commissioning of 200x160x98 (KVPC) Polycarbonate thermoplastics enclosure - junction box with I.P - 65 Protection with Terminals &cable hinged cover of approved design complete having gasket of internally embedded & made of polyeutherene & should be weather proof, rust proof, dust proof, water proof - box shall be tested as per IEC - 60670-2/60670-22. the box shall have self threaded holes & provision for mounting din rail. with 2 Nos cable gland including supplying & fixing crimping 2 nos lugs & 1 nos 32A connector 6 way for looping the incoming & outgoing cables and also connection of the street light one 6A SP MCB Including Connection of 2x6 sqmm Cable etc as Required. 382 Supplying of 6 mtr long hot dip Galvanized octagonal Pole with top of the pole 70 mm dia (A/F) and bottom of the pole 130 mm dia (A/F) made out of 3mm sheet with MS base plate of size 200mm (NS) x 200mm (NS) x 16mm (NS) on precast RCC foundation complete with suitable size openinginside the pole with flush weather proof door with locking facility preferably with LN key having proper arrangement with Accommodating of 1 Nos. 6 Amp.,10 KA MCB & neutral link4 way connector suitable for 25 Sqmm cable complete with electrically safe including inside cable termination with thimbles i/c wiring from pole box to fitting with 3x1.5 sq.mm. FRLS PVC insulated copper conductor wire, earth connection, din channel, earth stud and other accessories pertaining to this pole (But without street light fitting) etc as reqd.including providing & laying in position suitable RCC foundation as required for 6 mtr. octagonal hot dip Galvanized Pole as per Manufacturers drawing with 1:1.5:3 concrete (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including excavation of all kind of earth such as all type of soil/soft rock or hard rock etc. as per existing site condition i/c providing, cutting, bending and placing reinforcement & IncludingJ typefoundation bolts , anchor plate and templates in position as per manufacturer Standard and Providing PVC Pipe for Cable Entry and Exits Including Disposal of Surplus Malba / Softrock / Hardrock Stone etc.as Required. 383 Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing laid in ground including cost of digging upto required depth, 150 mm sand all around the cable, brick protection and back filling, clamped to wall with suitable clamps including saddles fixing bolts, Connection Testing and commissioning as Required. 384 2x6 sqmm 385 Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing trenches/pipes, cable trays, ducts, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning as Required. 386 2x6 sqmm 387 Supply, Installation, Testing and Commissioning of 120w Flood Light, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light, suitable for highlighting architectural facade and general purpose lighting. 388 SOLAR POWER SYSTEM 389 Supplying, installation, testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including space frame 390 (SCHEDULED ITEMS - AS PER DSR (E&M) 2022 391 (A) Supplying , installation , testing and commissioning of electric driven terrace pump suitable for automatic opeartion and consisiting of the following, complete in all respects as required:( Terrace pump) 392 (B) Horizontal type, multistage, centifugal, split casing pump of cast iron body & bronze impeller with stainless shaft, mechanical conforming to IS:1520 393 © Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 hz, AC supply with IP55 clas of protection for enclosure, horizontal foot mounted type with class-F insulation, conforming to IS-325. 394 (d)M.S fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. 395 (E)Suitbalecement concrete foundation duly plastered and with anti vibration pads. 396 Discharge : 450 liter per minute 397 Head : 35 meter 398 Providing, laying, testing & commissioningof C class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flangers, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 399 100 mm dia 400 Providing, laying, testing & commissioning of B class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc, and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 401 100mm dia 402 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required: 403 Single headed Stainless steel. 404 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 405 100 MM NB 406 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 407 100 NB 408 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 409 100 mm dia. 410 Supplyinig and fixing 63 mm dia , 15 mm long RRL hose pipe with 63 mm dia male and female couplings duly bound with GIwire , rivets etc.confirming to IS 636 (type-A) as required: 411 Supply, fixing first aid Hose Reel with MS costruction spray painted in post office red , conforming to IS 884 complete with the following as required 20 mm nominal internals diawater hoseThermo plastic (Textile reinforced) type -2as per IS 12585) 20 mm nominal internal dia gun metal globe valve & nozzle Drum and brackets for fixing the equipments on wall .connections from riser with 25 mm dia stop gun metalvalve & M.S . Pipe and socket.40 M 412 Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS 903 Suitable for instantaneous connection to interconnect hose pipe coupling as required:Stainless steel (Grade 304) 413 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 414 2 way-100 mm dia M.S. Pipe 415 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 416 TOTAL- A(SCHEDULED ITEMS - AS PER DSR E&M 2022) 417 (NON SCHEDULED ITEMS - AS PER MARKET RATES) 418 Supply & erection of ISI marked portable fire extinguishers, confirming to IS:15683, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions ofEngineer-in-charge. 419 Water CO2type. 9 Lt. capacity 420 D.C.P.Type 6 kg. capacity 421 ABC dry powder Type 6 kg. capacity 422 CO2 gas type. 6.5 kg. cap. -Trolley mounted 423 Providing & fixing neoprene rubber double flangedrubber expansion joint(anti vibration bellow) of standard length as per manufacturers specifications. suitable for hydrostatic test pressure of 21 kg/sqcm including all necessary fittings i.e. rubber gasket, nuts, bolts, washers etc complete as required. 424 100 mm dia. 425 150 mm dia. 426 Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. 427 Supply, fixing, testing & commissioning of 25 mm dia inspecting and testing assembly with gun metal valve, sight glass, by pass valve and connection to the drain line as required to complete the system. 428 Providing and fixing of cast iron body 100 mm dia Draw out connection in Under ground water storage tankwith heavy class MS suction pipe of required length,foot valve, suction coupling in conformity with local regulations complete in all respects. 429 Providing and fixing weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm)outdoor typemade of not less than 16 SWG MS sheethaving glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos.15 meter long fire hose pipes, branch pipeas required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted onself standing mounted type MS Angle iron frame as required. The words FIRE HOSE to be painted on the box. 430 Providing and fixing standard fire hose cabinet door with frame (900 mm x 2000 mm ) or (suitable to fit in the duct made of not less than 16 SWG MS sheethavingglass hinged door (5 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words FIRE HOSE to be painted on the box. 431 Supply, installation and testing of cylindrical type flanged pressurevessel tank, 450 mm dia, 2 m long and of 10 mm thick M.S., common for a set of fire pumpsincluding flanged connection, suitable supporting legswith MS plate of size 75x75x5 mm at the bottom and grouted in CC foundation. The air vessel tank shall be provided with air release valve, stop cock, safety valve, pressure gauge, 50 mm dia drain valve, suitable length of connecting pipe and valve from delivery header to vessel tank, suitable pressure switches to operate all pumps (1 nos each), tested to min 25 KG/cm2complete including painting with synthetic enamel paint of approved shade with all accessories as per direction of the Engineer-in-charge. (For Pump House) 432 Providing & fixing 100 mm dia dial pressure gauge including making connections with MS pipecomplete in all respects. 433 PART-A EQUIPMENT 434 OUTDOOR UNITS (HEAT PUMP TYPE) 435 Supplying,installing,testingandcommissioningofaircooled variable refrigerant volume / Flow modular typeairconditioning system with R410a refrigerant. The PCB Chamber of outdoor unit should be refrigerant cooled suitable for 415±10% 3 Phase, 50 cycles. The unit shall consist of indoor and out door units withindividual controllerasperdetailgiveninspecifications andhaving followingitems:(Theseitemsareto be giveninIndian rupeeswithcustomduites,inlandfrt,clearanceetconSitebasis) 436 Modular type outdoor units equippedwith highlyefficient 100% inverter type hermitically sealed scroll compressors, minimum two comprossors for and above 14 HP modules, with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and manufacturer of compressor and outdoor unit should be same. The Unit should have automatic refrigerant charge function. The static pressure of the outdoor unit shall be more then78Patoavoidhotairrecirculation.The unitshallbeabletooperateuptoto45°Cin coolingmode.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respecttoloadforbettercomfortandenergy efficiency etc complete as reqd. The units should have free phase technology for countinued operation. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping .The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 of following capacitites: 437 Cost of R 410 A Gas should be inclusive 438 The outdoor unit should include all loading, unloading, transportation, power cabling/wiring from near the indoor and outdoor units respectively. 439 The outdoor unit should include all loading, unloading, transportation, power cabling/wiring,( Y/T joints which is required for ODU Zone requirement Modules) from near the indoor and outdoor units respectively. Outdoor Units-Heat Pump , Fully Gas Charged and Aluminum fins within the ODU (condensing) unit shall be coated with polysiloxane based coating. 440 The Vendor should considere the deration on ODU election as per Singroli MP Ambient conditions 441 18 HP Outdoor unit VRV/VRF Zone-01 442 16 HP Outdoor unit VRV/VRF Zone-02 443 22 HP Outdoor unit VRV/VRF Zone-03 444 26 HP Outdoor unit VRV/VRF Zone-02 445 INDOOR UNITS 446 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree CDB and 19 Degree C WB temperature. 447 Ceiling Mounted Cassette Unit 448 300-318 CFM / 0.63-0.80 TR 449 310-335 CFM / 1.0 TR 450 600-670 CFM / 1.2-1.3 TR 451 812-830 CFM / 1.6-2.0 TR 452 850-865 CFM / 2.5-2.8 TR 453 1130-1165 CFM / 3.1-3.2 TR 454 Ceiling Mounted HSP Ductable Unit 455 1130 -1150 CFM / 3.0-3.40 TR 456 1200-1377 CFM / 3.95-4.0 TR 457 1600-2050 CFM / 4.5-5.5 TR 458 2047-2295 CFM / 6.36-7.1 TR 459 REMOTE CONTROLLERS 460 Supply, installation, tesing and commissioning of Imported Remote controllers (Corded) for operation of ductable indoor units and AHUs. 461 Touch screen controller for indoor units controller - VRV 462 Supply, installation, testing and commissioning of touch screen controller (Which is controlled 45 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls. 463 REFNUTS /T/ Y-JOINTS 464 Supply, installation, tesing and commissioning of Imported fittings Y-joints insulated, distributer and headers for all Indoor units at both the ends floors layout as per layout drawings.All interconnecting joints, Y Joints withpolysiloxane based coating 465 REFRIGERANT PIPING 466 Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation between each set ofindoor & outdoor units asper specifications, allpiping inside the room shall be properly supported with hangersandv All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 467 06.35 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 468 09.52 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 469 12.70 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 470 15.88 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 471 19.05 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 472 22.22 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 473 28.58 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 474 34.92 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 475 41.30 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 476 TRANSMISSION & CONTROL WIRING 477 Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller. 478 2C x 1.5 Sqmm Cu Cable or as per Manufacturer OEM 479 Perforated GITray with hangers & supports for copper piping (250 mm wide) 480 Refrigerant-410a 481 Supply , charging & Leackage testing of refrigerant -410a in additionalcopper piping circuit. 482 CONDENSATE DRAIN PIPE 483 Supplying, fixing,testing and commissioning offollowing PVC pipes for condensate drain duly insulated with Fire rated Class O kinny foam /Nitrile Rubber & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the AHU/FCU units upto the main header in the shaft dor vertical risers) 484 65mm dia 485 50mm dia 486 40mm dia 487 30mm dia 488 25 mm dia 489 TOTAL CARRIED OVER TO SUMMARY ( PART-A EQUIPMENTS) 490 PART-B VENTILATION 491 Propeller fan 492 Supply,installation,testing and commissioning of Certified Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen and Speed Regulator. 493 200 mmdia propeller fan,with single phase motor 494 300 mmdia propeller fan,with single phase motor 495 450 mmdia propeller fan ,with single phase motor 496 Inline fan 497 Supply, installation, testing and commissioning ofCertified Circular/Rectangular swing type Inline fan with fiire retardent Canvas connection Speed Regulatorof the following capacity of approved make and specification. 498 100-300 CFM,5-7 mm SP WG with Single phase motor 499 350-400 CFM,10-12 mm SP WG with Single phase motor 500 600-800 CFM,10-12 mm SP WG with Single phase motor 501 Tube Axial Flow fans 502 SITC of Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation respectively Normal/Smoke case. 503 SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `F insulation.Fan efficiency should not be less than 70 %, noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions. Fans should be as per specification and drawings. (As per Vent. Fan Schedule ) (Makeup Air & Pressurization Fans with St. Press. of 40 mmWG/Make Up Air Fan at 30mm WG) 504 6000 CFM (For Stairwell/Liftwell Pressurization) 505 6500 CFM (For Smoke Extract,with H Class insulation) 506 AIR SIDE WORKS 507 Site Fabricated Duct - GI duct 508 Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, Gripple supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. 509 0.63mm (24 gauge) GSS 510 0.8 mm (22 gauge)GSS 511 Factory Fabricated Duct - GI duct 512 Supply,Installation,balancing and commissioning of factory fabricated GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, Gripple supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. 513 0.63mm (24 gauge) GSS 514 0.8 mm (22 gauge)GSS 515 Supply, Fabrication, Installation and testing of Insulated Al. Flexible ducts in accordance with the approved shop floor drawings and specifications and shall also confirm to the BIS specifications. 516 200 mm Dia. 517 150 mm Dia. 518 Grilles/Diffusers 519 Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. 520 Aluminium supply air grilles with damper. 521 Aluminium return air grilles without damper. 522 Aluminium supply air square diffuser with damper 523 Aluminium return/exhaust air square diffuser without damper. 524 Aluminium return/exhaust airValve circular/squirell diffuser without damper. 525 Fresh Air/Exhaust Air Louvers 526 Supplying and fixing ofextruded aluminium louvres with frame bird screeen , mounting arrangement etc. as per specifications and drawings. 527 Fresh Air/Exhaust Louvers 528 Supply,Installation,Testing and commissioning of doble layer canvas connection with 1/2 hr. fire ratingasper specification. 529 MECHANICAL INSULATION 530 DUCT LINE ACOUSTIC TREATMENT 531 Supply and installation of cross linked open cell Oxide Acetate( AccoIsolate) Foam Acoustic insulation on ducts having density of 30 to 60Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 532 15mm thick Oxice Acetate Acco IsolateAcoustic open cell insulation on one side for Duct acoustic insulation 533 DUCT LINE THERMAL INSULATION 534 Supply and installation of cross linked closed cell Oxide Acetate( Thermo Isolate) Foam Thermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 535 25 mm thick insulation oxide acetatefoam with 2 coat layer of 7 mile cloth with starbond or eql. adhesive on Exposed supply air duct 536 13 mm thick insulation oxide acetatefoam laminated with aluminium foil supply air duct 537 9mm thick insulation oxide acetatefoam laminated with aluminium foil supply air duct 538 EXPOSED ROOF INSULATION 539 Supply and installation of cross linked closed cell Oxide Acetate( Thermo Isolate) Foam Thermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 540 19mmthick oxide acetate insulation for underceck plain 541 TOTAL CARRIED TOSUMMARY(Mechanical Insulation works) 542 ASSOCIATED ELECTRICAL WORKS 543 Therates for the distribution boards from the Breakers andinstrumentsshall also include the following : 544 Wiring forlight / Fan points with 1.5 sq. mm PVC insulatedcopper conductor1100 Volt grade strandedflexible FRLS wiresofapproved makein1.6mmthick25mmdiaMS conduitincluding costof providing & fixing saddles, hangers, supports, cutting chases and filling chases for recessed conduiting, and including the cost of providing and fixing a6 amp240Volt ModularPlatetypeswitchesof approved quality,colour, makeanddesign with mouldedcover platein zinc chromate passivated MS box and including the cost of running 1.5 sq. mm PVC insulated copper earth wire for loop earthing etc. complete 545 TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequatesize of neutral link. 546 All MCB’s shall be of minimum 10 KA breaking capacity and MCCB s shall be not lessthan 25KA 547 The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermalmagnetic microprocessorreleasesas per BOQand following : 548 i.MCCB rating upto 250 Amps with thermal magnetic releases. 549 ii. MCCB above 250 Amps with microprocessor releases. 550 All MCB’s used for protection ofresistiveand lightlyinductive loadshallbetype “B”characteristic and inductive(motor)loadshall be of type “C” characteristic. 551 Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993. 552 i.IP 42 for indoor panels. 553 ii. IP 55 for ODU panel. 554 AllMCCB’sshall beprovidedwithoperatingmechanismfordoorinterlock. 555 All hinged door shall be earthedthrough2.5 sq mm tinnedbraidedcopper wire. 556 Providing cableclamps/ supportswithin distributionboardscablealley. 557 Current density of aluminium shall be 1sq mm for 1.0 Amps for ratedcurrent of bus bars. 558 Model, current capacity location and frame size of switchgear shall be writteninside of thepanel doors with paint / permanent marker asapproved shop drawings / site requirment. 559 All meter shall be digital type and all starter shall be as per Type-2 Coordination chart 560 Current Transfomer shall be resin cast. 561 All Panel Shall be BMS Compitable 562 AHU/Fan Panel 563 Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness. 564 The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. (ALL AHU PANEL WITH 565 In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire.All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules. 566 Vent. Fan Panel- MCC -1 567 Incoming 568 1 no. 63 amp MCCB 569 Phase indicating lights with control fuses. 570 Breaker ON/OFF/TRIP indicating lights. 571 Bus Bars 572 100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves. 573 Outgoings 574 3 nos. 6-10 A,TP MPCB(With DOL Starter) 575 The base frame shall be 75 mm x 5 mm. 576 Panel as described above and in drawings. 577 METER BOARD / SUB PANELS 578 Supplying, Installation, Testing and Commissioning of dust, damp and vermin proof free floor standing / wall mounted factory built sheet steel enclosed modular construction extendable panel, suitable for operation on 415 + 10% volts, 50 Hz AC 3 phase 4 wire system fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with aluminium bus bars, interconnection with solid copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per drawing and technical specifications attached etc. complete as required. 579 ODUs Panel-01-TERRHVAC 580 Same as above item but outdoor Panel with following accessories. 581 INCOMING: 582 1 No. 200 amps, 415VTPN MCCB with overcurrent and short circuit releases, all indication, push button etc. 583 Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set 584 (0 - 200 A) CT operated Ammeter with selector switch& 3 nos. CTs ratio 200/5A , 15VA burden & accuracy class of 1.0 - 1 set 585 0-500 V Voltmeter with selector switch - 1 set 586 BUSBAR: 587 250 Amp. TPN, 35 kA Al. Bus Bar 588 OUTGOINGS: 589 80A, TPN ELCB with 300mA- 3 Nos. (Incl. 1No. Spare) 590 40A, TPN ELCB with 300mA- 5 Nos. (Incl. 1No. Spare) 591 ODU Panel Described as above/As per Manufacturer ODU Configuration. 592 Spcl. Note : All Above mentionedpanel SITC as per actual GA dwgs. equipments and final config,. Of ODUs. 593 CABLING (POWER ) 594 Power Cabling and Earthing: 595 Spcl. All Cables Should be fire survival Cables (FRLS) 596 Supply, installation, testing & commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 597 3Cx10 Sqmm 598 3Cx06 Sqmm 599 3Cx04 Sqmm 600 4Cx06 Sqmm Cu 601 4Cx10 Sqmm Cu 602 Control Cabling 603 Supply, installation, testing & commisioning ofCopper conductor , PVC insulated, PVC sheathed armoured cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers and AHU to Control Consol Panel). 604 8C x 1.5 Sqmm 605 Supply, installation, testing & commisioning of cable termination of above cables with copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required. 606 3Cx10 Sqmm 607 3Cx06 Sqmm 608 3Cx04 Sqmm 609 4Cx06 Sqmm Cu 610 4Cx10 Sqmm Cu 611 Supplying and installing following size of perforated G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders including G.I. bolts & nuts, painting of suspenders etc. complete as required. 612 100 mm. Width x 50mm. Depth x 1.6mm. Thickness. 613 150 mm. Width x 50mm. Depth x 1.6mm. Thickness. 614 225 mm. Width x 50mm. Depth x 1.6mm. Thickness. 615 Providing and fixing following size of G.I. strip / G.I. wire on surface or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring / on cable tray/ on surface including G.I. clamps etc. complete as required. 616 6 SWG G.I. wire 617 Electrical work i.e. 618 3 Pin socket switch for Cassette, fcu, inline fan, propeller fan etc. near to the each unit. 619 Isolator Switch (Weather Proof) near to the each ODU. 620 Copper wiring /earthing from Isolator switch to M/C (chillers, pump, AHU , Fan etc.) 621 All DOL Starter Panel and Power cable for Fans/AHU 622 RCC Foundation for chiller, pumps, panels/outdoor units etc.. 623 Spcl. Note:The work includes design, supply, fabrication, erection, testing & commissioning of the complete air conditioning system with items specified above. 624 Supply Installation , Testing & Commissioning of 8 Passangers, 544 Kg. 1mps. Automatic Elevator, with VVVF and Microprocessor based Simplex Collective Selectivewith/without Provision ofattendant control. Separate Landing Push Button Box for all Landings with scrolling indicator. with provision of Attendant control, having 2 stops , 2 Openings with SS Cabin (Hair Line Finish) havingCross flow fan for Ventillation , having sleek (SS hair Line finish-PVC) and LED small Circular lighting all complete. 625 Other Features 626 Battery Operated Emergency Light And Alarm Bell 627 Call Register Signal And Vf Door Operator 628 False Ceiling In Car 629 Vandal Proof S.S. Button With S.S. Cover 630 Firemans Switch 631 Infra Red Door Screen 632 Full Car Operating Panel 633 3 Way Intercom / Press And Speak Phone 634 Push Button - Orange L E D Illumination 635 Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour 636 Automatic Rescue Device 637 Minor Builders Work 638 Scaffolding 639 Floor Annunciator With Music 640 Braille Buttons 641 Sill Support 642 Lift License 643 Overload Warning Indicator With Audio Announcement 644 Pit Ladder 645 Auto Light & Fan Switch Off (Pod) 646 SUB HEAD - I: CIRCUIT CUM POINT WIRING 647 SWITCH CONTROL LIGHT POINTS 648 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 649 Group C 650 MCB CONTROL LIGHT POINTS 651 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 652 Primary point controlled by one MCB. 653 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 654 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 655 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 656 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 657 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 658 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 659 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 660 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 661 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 662 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 663 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 664 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 665 Telephone socket outlet 666 SUBHEAD -II - FITTINGS & FIXTURES 667 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 668 Supply, Installation, Testing and Commissioning of 40W LED POST TOP LANTERN 669 Supply, Installation, Testing and Commissioning of 40W LED GATE LIGHT 670 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 671 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 672 SUBHEAD - III - DISTRIBUTION BOARDS 673 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 674 12 way, Double door 675 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 676 Single Pole 677 Single Pole Neutral 678 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 679 40 A 680 63 A 681 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 682 40 A 683 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Madhya Pradesh View Result →
37.
Agriculture #9479276 Technical Bid
Supply Of Electrical Goods General , Push Button Element 1No+1Nc Vaishno Make , Single Phase Tester Taparia Make Size 6 , Req/Isulator For Cane Unloader Size 6” , Shaklo Insulator For Ltline Protection , Connector Link Elmax Make Size 6 Mm , Dobut Size 16 Mm , Dobut Size 25 Mm , Dobut Size 35 Mm , Dobut Size 50 Mm , Pvc Steel Grip + Tape Size 3/4” Length 10 Mtr , Cotton Tape Size 3/4” , Porceline Kit Kat Standard 20Amp. 240Volt , Dobut 32Amp. 240Volt , Dobut 32Amp. 440Volt , Bowel Element 750 Watt , Soldring Iron 35W , Soldring Paste , Soldering Wire 0-10 Swg Bharati 80%& 20% , C.R.C. 2-26 (300 Ml) , Insulatingvarnish Dr.Back Make Elmoluft 1A , Varnish Bectrol Grey / Red , Thinner Dr. Backmake 218 For V-155 , Dobut 205 For V-155 , Dobut 234 For V-155 , Havels Force-10 Exhaust H.D. Fan 18”, 250V , 1500 Rpm. Single Phase , Dobut18” , 250V , 1500 Rpm. Three Phase , Do But 12” , 250V , 1500 Rpm. Single Phase , Do But 24” , 240V , 1000 Rpm. Single Phase , Dobut 24” , 240V , 1000 Rpm. Three Phase , Blower Fan , Push Button Green /Red Vaishno Make , Push Button Element Vaishno Makeno & Nc , Push Button Station Colour Light Grery , Bulbs 24V 60 Watt , Bulbs 24V 100 Watt , Fuse Base Vaishno Make 250Amp. , Do But400 Amp. , Do But630 Amp. , Condensor 4 Mfd, 440 V, Usha /Asian Make , Do But 2.5 Mfd , Do But 3.15 Mfd , Condensor 8 Mfd , Do But 10 Mfd , Do But 20 Mfd , Do But 33 Mfd , Milimax Paper 7 Mile , Milimax Paper 5 Mile , P.T. Holder 100 Watt Anchor Make , S.C. Holder 100 / 200 Watt Jyoti/National Make , Do But 300 / 500 Watt , Combination Plier 8” Taparia Make , Tube Side Holder For 40 W , Tube Side Holder Backlite Stand Single/Double , Three Pin Porceline Holder For 125 Hpmv Lamp , Tube Lite Rotary Holder Base (Single Fitting) , Tube Lite Rotary Holder Base (Double Fitting) , Indicator Lamp 40 Lad , Change Over Switch Standard 200 Amp 440V , Change Over Switch Standard 400 Amp 440V , Do But 630Amp 440V , C.T.C. 400 Ml , Sc Holder 300 Watt For Sodiam Hanging Light , Pvc Motor Cooling Fan I H.P. , Do But 03 H.P. , Do But 05 H.P. , Do But 7.5 /10 H.P. , Do But 15 H.P , Do But 20 H.P , Do But 25 H.P. , Do But 30 H.P. , Empire Tape 1” Of Mt , Empire Tape 3/4” Of Mt , Glass Tape 1” Ofmt , Glass Tape 3/4” Ofmt , Semi Conductor Fuse Gec Make 1000/850/630/300/250A,600V , Potententio Meter 2Ko-5410-10 Pankaj/Pawan Make 2K5-500W , Fuse Carriar 125Amp Vaishno Make , Timer Em-2000,4-120 Sec 240 Vac, 50Hz , Fuse Link Type Tis 63 Amp , Fuse Link Typetia 32 Amp , Glass Fuse20mm , 01Amp To 10Amp. , Element 250Watt , Do But 150Watt , Semi Conductor Fuses 1250 Amp., 660V, 170L 7035 38T/50 90415 Ty Power Silicon/Bushmen Denmark Make , Do460amp. 660V, Gsmj/170M 5239-500 Mp.1000V , Do 460Amp. 660V, Gsmj/170M 5239-500 Amp.1000V , Semi Cunductor Fuse 700 Amp., 690 Volt, 170 M 6111 Bushmen Denmark Make , Diode Rectifier 321Ur 100G, Reverse / Forward (Ruttonshaw) , Diode40hm 120G, Reverse / Forward(Ruttonshaw) , Pvc Connection Elemax Make Cts750v 35A , Do But 25A , Do But 16A , Do But 10A , Limit Switch415v,Llgs Bch Make , Rpm Meter 0-600Vdc ,1950Rpm,Fsd 1Mile Amp 96 X 96 With Calibration Card , Automatic Voltage Regulator With Time Delay , Lt Control Switch With Changeover3la202-1A , Digital Multimeter Meco Make , Thyrister St -330C14co Itally Make , Proximaty Switchs-30V , Glass Sleeve Size 1 Mm , Glass Sleeve Size 2 Mm , Glass Sleeve Size 3 Mm , Glass Sleeve Size 4 Mm , Glass Sleeve Size 5 Mm , Glass Sleeve Size 6 Mm , Glass Sleeve Size 8 Mm , Glass Sleeve Size 10 Mm , Glass Sleeve Size 12 Mm , Glass Sleeve 25 Mm , Glass Sleeve 35 Mm , Glass Sleeve 50 Mm , Glass Sleeve 70 Mm , Bridge Rectifier25amp. Routtanshaw Make , Fuse Link Ee Make 32 Amp. , Fuse Link Ee Make 63 Amp. , Potentio Meter 2K- 50Hm Rw-3K , M.C.B. Havells/L&T Make Single Pole 3 Amp , Do But 6 Amp , Do But 10 Amp , A.B. Contactor Lcid/73 16 Amp With Auxiliary Block , Push Buton Element Teknik Make , Potentio Meter2k5 3W Pankaj Make , T.C.Contactor 2No+2Nc With Aux. Block , T.C.Timer 0-30 Sec. Contactor Mount On /Off Delay , Indicating Lamp 7/10W With Lamp 220V (Pin/Screw Type) , Push Button Station With Box L&T Make , Hrc Fuse Link 32 Amp. Ee Make , Bkt Kit Kat Fuse Assly.. 63A Ee Make , Amp. Meter 0-5000Amp. Ctr 4300/5 1450X1450mmae , Kw Meter 0-3000Kw 1450X1450mm Ctr 4300/5Ae/L&T , Moving Arching Contact For 300A Ocb Mei Make , Dobut 400 Amp , Bch Make Timer 0-60 Sec.Single/Double Stage , Power Capacitor 3 Phase, 515 Volt, 25Kvar L&T Make With Test Certificate , Relay For Automatic Power Factor Controller 12 Stage , Carbon Bush Holder For Cane Unloader20 X 20 X 100 , Digital/Analog D.C. Ammeter 0-1500Amp.Ae/L&T Make Esd 1Ma 1.5 , Digital/Analog D.C. Ammeter (Alolog/Digital) 20-0-20 As 1248, Fsd 70-0-70 Mvm 96 Ae/L&T Make , Digital/Analog D.C. Voltameter 0-600V, M96, S1248, Fsd-1Ma Ae/L&T Make , Digital/Analog D.C. Voltameter M-96, S-1248, Fsd-1 Ma Ae/L&T Make , Slipring Suitable For 200 Hp Slipring Motor Bore 51Mm Ring Od 145Mm , Spare For Advance Make Ocb Type N2 Rating 300Amp.Spare Arching Contact , Do But Spare Moving Contact , Do But Spare Fixed Contact , Techo Generator Model Dtg 4000 Output 200 Vtc/4000 Rpm Maximum 400Mm Ador Make , Power Block Thyristor Type Tt75n/Mcc501-16102 Dixys , Thyrister Dcr-604 Se 1616 , Do But Dcr 604 , Do But Dcr, 1004 S/D 1616 , Do But St 2600/14 , Do Butdcr 806 / 807 , Carbon Bush(Asam Carbon Make) , Carbon Bush Size 25 X40 X 50Mm Eg-224 , Carbon Brush Size 20 X 40 X 50Mm Eg-224 , Do But 13 X 32 X 40Mm Eg-224 , Do But 12.5 X 32 X 40Mm Eg-224 , Do But 16 X 32 X 40Mm Eg-224 , Carbon Bush Size 20 X 20 X 100Mm Eg-224 , Carbon Bush Size 12 X 25 X 30Mm Eg-224 , Carbon Bush(Copper Mixed) For Slipring Motor 25 X 50 X 60Mm Bh-51 Asam Carbon Make , Do But 22 X 32 X 40Mm Bh-51 , Do But 5 X 19 X 25Mm Bh-51 , Do But 16 X 32 X 40Mm Cb-6 , Do But 20 X 40 X 50Mm Cb-6 , Graphite Carbon Bush (In Two Pcs) Size 45 X 40 X 20Mm Asam Carbon Make , Carbon Brush Holder For Above , Wolfmake Drill Machine , Slipring Holder For 200 Hp Motor , Slipring 5 Hp Kec Motor Id 500Mm , Change Over Switch 630A, 4 Pole S.S. Havells/Hpl With Test Certificate , Motor Connection Plate 120/90Hp Slipring Motor (Kec) , Motor Connection Plate 55Hp Slipring Motor (Jyoti) , Motor Connection Plate 33Hp Slipring Motor (Kec) , Motor Connection Plate 55Hp Slipring Motor (Ngef) , Slipring Holder 110 Kw Ngef Make Motor , Slipring Holder 200Hp Aei Make Motor , Dowells Paste , R.P.M. Meter Suitable For Thyrister Convertor Pannel (D.C.Pannel) Fsd Ima M-96 Meco Size 1200-0-1200Rpm , Digital/Analog A.C. Ammeter Of 0-800A Ctr-800/5 L&T Make , Digital/Analog A.C. Ammeter Of 300A Ctr-300/5 L&T Make , Digital/Analog A.C. Ammeter Of 200A Ctr-200/5 L&T Make , Digital/Analog C.T.S. For Ratio 0-800A Ctr-800/5 L&T Make , C.T.S. For Ratio 200A Ctr-200/5 , C.T.S. For Ratio 100A Ctr-100/5 , C.T.S. For Ratio 60A Ctr-60/5 , C.T.S. For Ratio 300A Ctr-300/5 , C.T.S. For Ratio 400A Ctr-400/5 , Volt Meter Ae Make For 0-500V Ac Size 140X140mm L&T Make , Volt Meter Ae Make For 0-500V Ac Size 95X95mm L&Tmake , Amp. Meter 1000Amp Ctr 1000/5 Size 95 X 95 L&T Make , Amp. Meter 400Amp Ctr 500/5 Digital/Analogl&T Make , Amp. Meter 250Amp Ctr 250/5 Digital/Analogl&T Make , Amp. Meter 300Amp Ctr 300/5 Digital/Analogl&T Make , Pneumatic Timer Bch Make In Single Stage For 0-60Sec , Pneumatic Timer Bch Make In Double Stage For 0-60Sec , Potentio Meter Ec Make 5Ka Type 5710 , M.C.B. Havells Make16 Amp , M.C.B. Havells Make20 Amp , Bkt Kit Kat 63 Amp L&T Make , Bkt Kit Kat 32 Amp L&T Make , Bkt Kit Kat 16 Amp L&T Make , S.S.Tension Spring For 500 Hp Motor C.B.Holder , 3 Phase Cooling Fan For 100 Kw Thyrister , M.S.Star Coupling As Per Sample , Carbon Brush Holder For Techo Generator As Per Sample , Bkt Fuse Carrior 125 A L&T Make , Power Thyristor 7 T 75 N , D.C.I.A.Mk-Iii Kec Make , New Work Cardkec Make , Bearing For Techo Generator Big Size , Bearing For Techo Generator Small Size , Indicating Lamp 220 V Dc Bch Make , Heating Element Rod 2000 W 2”/1” , Pressure Switch 4.5 Kgs Indofos Make Ips 70 , Digital Clamp Meter (Tingue Tester)1000A Motwani Make , Continuity Tester With Cell , Resistance 160 W 1-K As Per Sample , Capacitor 0.6 W 1200 Volt As Per Sample , Resistance 50 W As Per Sample , Soldering Strip (Lead Tin 60:40) , Soldering Wire 18 Swg , Soldering Flux Frysol Cooleson India Limited Make , Hydro Meter For Battery Leding , Copper Flexible Lead With Fibre Glass Insulated 10 Mm , Copper Flexible Lead With Fibre Glass Insulated 25 Mm , Copper Flexible Lead With Fibre Glass Insulated 35 Mm , Copper Flexible Lead With Fibre Glass Insulated 50 Mm , Mcb Tp 63 Amp Havells/ L&T Make , Mcb Tp 32 Amp Havells/ L&T Make , D.P.Switch 32 Amp Anchor/ Havells Make , Heating Rod 1000 Watt 2 Ft. Long , Heating Rod 1000 Watt 1 Ft Long , Backelite Sheet 20 Mm 4’ X 4’ , Carbon Brush For Grinder , Tpn Switch 63 Amp Havells/L&T Make , Axial Blower Fan For 700 Hp Thyrister Control Panel Thyrister Modular Make E.B.M. Module Azd-250, Aa-08-19254/440 Volt 60 Hz 2900 Rpm Made In West Germany , Mager For 500 Volt Mannual Operating , Heating Rod Of 2000 Watt 3 Feet Long U Shape , Handle For Acb 3200 Amp Type Draw Out Cncs , Carbon Brush Holder For 7.5 Hp Motor , Nomex Paper F- Class 7 Mile , White Paper7 Mile , Contactor T.C. 500 Amp , No Volt Coil 220 Volt Ac For Contactor 500 Amp T.C. , Add On Block For Above Contactor , Carbon Brush For Techo Generator , Fibre Fix Plate Suitable For Credle Assembly For Above L&T Make A.C.B. , Thyrister Mdt 2500/28 E (37Mm) Dcr 1476Sy2929 Imp Semikrim Thyrister , Semiconductor Fuse 1600 Amp, 1000V, Super Power 170 T 8173 4 Bk/90 90275 Busman Denmark , Brass Holder For 562 Kw Kec Make Dc Motor , Brass Holder For 700 Kw Kec Make Dc Motor , Carbon Brush Round , Carbon Brush Squire , Carbon Press Steel Spring , Digital Meger 1000V, 1000Mr Motwani/Rishabh Make , S.T.Bulb 300 Watt , S.T.Bulb 500 Watt , Auto Manual Selector Switch 2 Pole 2 Way L&T Make , Current Transformer 400/5A, 15 Va Clean-1 , Terminal Plate (Assembly) For Acb , Digital Energy Meter 415 Volt , C.T. 200/5 A.E./ L&T Make , Connection Plate For 4 Speed Meter , Mcb Box For 63 Amp Mcb , Spare Coil 240 Watt For Timer 0-60 Sec, 240 V Double Stage , Element For Timer Double Stage , Exhaust Fanblade Size 18 , Exhaust Fanblade Size 24 , Power Card (Pin-4) , Power Board For Analog Panel Srp-600 (700 Hp) , Under Voltage Release (Uvr) 220 Volt , Open Coil 220 Volt , Closing Coil 220 Volt , Plate (Complete Coil Set) , Ethernet Cable 03 Mtr , Cdp Connector , Control Card Kirloskar Make , Thyrister (Mcc501-16102) Dixys Make , Dc Volt Meter 0-600V Meco Make , Ampear Meter 0-500A Meco Make , Potentio Meter 2.5 Kvr , Thyrister Dcr-807 , Control Card (Con-4) , Power Card (Pin-4) , Power Card (Pin-51) , Dsl Card , Control Card For Vfd (2Nd Rake Cane Carrier) , Igbt With Thyrister For Above , Heavy Duty Limit Switch, General Purpose Cat Code Llgs Angular Liver , Pneumatic Timer, Coil-110V Ac, Type-Pcn, Range-05-60 Sec With Double Contact Block (1No+1Nc) Cat Code- Krtpcn11a-1 , Heavy Duty Arc Welding Machine Phase- Single Phase & Double Phase Current-310 Amp Make Bigboss
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Uttar Pradesh View Result →
38.
Public Administrative Department #9476141 Price Bid
Tender For Upgradation, Interior/Furnishing Work Of Commissioner Lucknow Division Lucknow Office - TOILET SANITARY FITTING WORK 2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes.DSR -18.8.2 3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal outer dia Pipes.DSR -18.8.3 4 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal outer dia Pipes.DSR - 18.8.4 5 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mmDSR - 17.10.1.1 6 Providing & Placing of Looking Mirror pasted on wall with the help of silicon having edges beveled, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge. Customized MR 7 Providing & Fixing ofConcealed Stop Cock With Trims as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 8 Providing & Fixing ofFloor Drainer as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent MR 9 Providing & Fixing ofWall hung Closet with Soft Close Seat Cover Fixed with Jumbo Bolts as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 10 Providing & Fixing of Concealed Cistern With Push Plate as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 11 Providing and fixing of Under Counter Basin as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 12 Providing & fixing ofSensor Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 13 Providing & fixing ofUrinal With Sensor as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 14 Providing & fixing ofUrinal Division Plate as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 15 Providing and fixing Sink Cock as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 16 Providing and fixing 2 Way Bib Tap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent MR 17 Providing & fixing Health Faucet as per the approveddesign all complete as per drawing, specification and direction of engineer incharge.Make-Kerovit/Equivalent MR 18 Providing and fixing of Angle Cock as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 19 Providing and fixing of Bottle Trap as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 20 Providing and fixing of Toilet Paper Holder as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 21 Providing and fixing of Towel Ring as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 22 Providing and fixing of Soap Dish as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 23 Providing and fixing of Waste Coupling as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-Kerovit/Equivalent MR 24 Providing and fixing of Long Braided Hos Pipe as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. MR 25 Providing and fixing of 10ltr Gyser as per the approveddesign all complete as per drawing, specification and direction of engineer incharge. Make-AO Smith/Equivalent MR 26 Providing and fixing of 110mm dia pipe 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 27 Providing and fixing of 110mm dia 90 Degree Elbow 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 28 Providing and fixing of 110mm dia 45 Degree Elbow, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 29 Providing and fixing of 110mm dia Coupler, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 30 Providing and fixing of 110mm dia Tee, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 31 Providing and fixing of 110x75mm dia Nahani Trap, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 32 Providing and fixing of 75mm dia pipe 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 33 Providing and fixing of 75mm dia 45 Degree Elbow, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 34 Providing and fixing of 75mm dia Coupler, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 35 Providing and fixing of 75mm dia Y Tee, 6kg pressure of Supreme/Astral make or equivalent, including supply of all materials, labour and T&P etc. MR 36 INTERIOR WORK ESTIMATE 37 Providing & Fixing of at all height false ceiling including providing and fixing of frame made of special section power pressed from m.s. sheet and galvonised in accordance with zinc coatingof grade 350 as per IS 277and consisting of angle cleat 25x1.6mm with flanges of 27mm and 37mmat 1200mm c/c one flangedfix to the ceiling with dash fastener 12.5mm dia and and 40mm long with 6mm dia boltto the angle hangers of 25x25x0.55 mm of required lengthened other end of angle hanger being fixed with nut and bolts to GI channel 45x15x0.90mm running at the rate of 1200 mm c/c to with the ceiling section 0.5mm thick button wedges of 80mm with tappered flenges of 26 mm each having clips of 10.5mm.at 450mmc/ cshall be fixed in direction perpendicular to GI channels with connecting clipsmade out of 2.64MM diax230mm longGI wire at every junction including fixing the gypsumboard with ceiling section and perimetre channels 0.50 mm thick 27mm high having flenges of 20mm and 30mm long ,perimeter of ceiling fixed to wall /partitionwith help of rawl plugs at 450mm c/c with 25 mm long drive all screws @230mm interval including jointing and fixingto a flush finish of tapperedend sq edge of board with recommended filler jointing and tapper finisher and two coat of primer suitable for board as per manufacturers specification and also including the cost of making of openning for light fittings grills diffusers cutouts made with frame of perimeter channelssuitably fixed all complete as per drawing and specification and direction of engineer incharge but excluding the cost of painting. 12.50mm thick tapered edge gypsum board.DSR-12.45.1 38 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. DSR -12.52.2 39 Providing & Fixing of Armstrong Suspended Ceiling System with Armstrong H4988 BP4988S DUNE Bev. Teg. 600x600x15mm (Microlook) EDGE TILES WITH ARMSTRONG Silhouette Exposed GRID. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm ,and 600x1200x15mm suitable for Green Building application, with Recycled content of 66% GW.The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour and with a web height of 38mm.Silhouette, Main Runners & Cross Tees to have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions. The T Sections have a Galvanizing of 90 grams per M2 and a load carrying capacity of 10 Kgs/M2.The Tile & Grid system used together, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge M.R 40 Providing & making false ceiling system with GI section frame work cladded with 12mm plySurface to be finished 4mm thick veenear complete with polishas per standard design all complete as per drawing and specification and direction of engineer incharge. M.R 41 Providing and fixing of 12 mm thick highglossLaminated wooden flooringrange grand illusion/studio Classification of Use 23/32 (Heavy Domestic/Domestic) with a Surface Abrasion Resistance of class AC3 (average 4500 cycles), Impact Resistance of IC2 (EN13329), Resistance to Cigarette Burn with a rating of 5 (EN 438-2:15), Swelling after 24 hrs in water of 15% (EN13329), Modulus of Rupture of 53.3 newton/mm2, Internal Bond 1.78 newton/mm2, Surface Soundness of 1.3 newton/mm2 (EN 13329:2000) with a 0.2mm thick wear layer on top of a High Density Fiber substrate core (density > 850 Kg/M3) of plank size 1212 mm X 137 mmhaving Uni fitlocking arrangement (lock strength > 1000 lbs/ft) with an underlayment made of natural colour foam , with accessories like End profile, Transition profile, reducer, etc. complete. The rate includes cost of all materials, accessories, labour, HOM, etc., complete at all levels. (The Shade, pattern etc., to be approved by Engineer in charge)Make-FloorMaster/Armstrong/Haro. all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-Charge. Make-Armstrong,Mikasa,Luxe EquivalentM.R 42 Providing and laying of printed saxony carpet of CARUSBrand, manufactured by Beaulieu International Group or equivalent, having 100% Type 6 Nylon/Polyamide Crealon or equivalent and 1/10 gauge, . The carpet should have a primary backing of woven pp and secondary backing of weaveback to ensure high performance and comfort. The carpet should be of 4M width to ensure lesser joints and minimum wastage. It should have a minimum total weight of 1650 gsm and minimum pile weight 800 gsm , minimum number of tufts to be 185040 or more The carpet should also qualify to the following minimum European standards performance specifications - (a) Fastness to rubbing, dry(ISO 105 X-12), minimum rating should be 4-5; (b) Fatness to rubbing, wet (ISO 105 X-12), minimum rating should be 5; (c) Water fastness, (ISO 105 E-01), minimum rating should be 4-5; (d) Fastness to light (ISO 105 B-2), minimum rating should be 5; (e) Thermal Resistance (ISO 8302), minimum rating should be 0,072 m² K/ W; (f) Impact sound insulation (ISO 140 - 8), minimum rating should be 25dB. The carpet should be Scotchguard ready for better stain resistance, and should have an approved fire rating of Class 1 under Bf1S1 and should be recommended for commercial usage under Class 23/32 classification.duly installed on smooth hard floor with support of 10 mm epe sheet & company recommended adhesive.M.R 43 Providing & Making & Fixing of Commercial Wall Panneling made with Aluminium Section of 2x1 @ 2CC frame work cladded with 12MM Ply complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 44 Providing & Making & Fixing of Commercial Wall Partition made with Aluminium Section of 2x1 @ 2CC frame work cladded with 9MM Ply on Both Side complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 45 Providing & fixing Toughned glass Parition with 12mm Modi float glass fixed edge to edge as per design and drawing and polished where required along with neccesary hardware all complete as per drawing, specification and direction of engineer incharge. M.R 46 Providing & Making & Fixing of Wall Panneling made with 1MM Laminate & 5.5MM MDF on Existing Surface complete with painted or polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 47 Providing & Making & Fixing of Wall Panneling made with 4MM Veneer on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 48 Providing & Making & Fixing of Wall Panneling made with 12MM Louver on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 49 Providing & Making & Fixing of Wall Panneling made with Coloured Lacquered Glass on Existing Surface complete with Melamine Polishe.as per the approveddesign all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 50 Providing & Making & Fixing of Storage Cabinet made of 19mm board, having shelves & shutters & teak wood beading & finished surface of 1mm thick Laminateincluding all hardware like tower bolts, hinges, lock & handle as per approved drawing & direction of Engineer incharge.M.R 51 Providing and Fixing Channeled Woodworks perforated panels of width 128mm, thickness of 16mm and length 2440 mm or as required by the Architect/ approving engineer, made of a high density particle board substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a (“Helmholtz” fluted perforation of 2mm width and 14mm of visible panel / 4mm width and 28mm visible panel) each. The panels shall provide a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece. The panels shall be mounted on special aluminium splines using clips. as per the approved designas approved by Engineer -in-Charge. M.R 52 Providing and supplying ‘Optra Acoustical Wall Paneling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and fire -resistant fabric with an option of colours as per the choice of the Architect/ Person in-charge of size 1200x600 or 600x600 mm providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using Wall panel impalers and construction adhesives as per the instructions laid down by the manufacturer as per the approved designas approved by Engineer -in-Charge. M.R 53 Providing & fixing of 12 mm Toughened Glass Door with all hardwareas per design with edge polish m/c top & bottom pivot and bottom lockwith handle all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 54 Providing & fixing of Flush Door Laminated both side complete with all fittings,Round mortis lock,door closer etc all complete as per drawing, specification and directionas approved by Engineer -in-Charge. M.R 55 Providing & Fixing of Plotter Cutted Designer Film of approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 56 Providing & Fixing of Wall Paper of approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 57 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. DSR-13.91 58 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.DSR-13.80 59 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm DSR-13.48.1 60 Providing and laying of Double Charged floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x1200mmMR 61 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm DAR-11.41.2 62 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.DSR-11.48.2 63 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm DSR-8.2.2.2 64 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.DSR-8.5 65 ELECTRICAL WORK ESTIMATE 66 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A DSR(1.10.1) 67 Supply and fixing of Power point and Supply and fixing of power plug with 10 Amp./250 volt flush type modular switch and 5 pin 10A /250 volt flush type universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. DSR(1.31) 68 Supply and fixing of wire, Power point and Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 nA/250 volt flush typ[e universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. DSR(1.32) 69 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire DSR(1.14.1) 70 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR(1.14.2) 71 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire DSR(1.14.3) 72 Supplying & Drawing co-axial TV cable RG-6 grade, 0.7 mm. solidcopper conductor, PE insulated] shielded with fine finned copper braid and protected with PVC sheath in the existing surface/ recessed steel/PVC conduit as required. For T.V. Socket outlet DSR(1.19) 73 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 20MM DSR(1.21.1) 74 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 25MM DSR(1.21.2) 75 Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 32MM DSR(1.21.3) 76 Supply and fixing of recess mounting round15 TO 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AAAS.I 1403 77 Supply and fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. CAT-AAAS.I 1406 78 Supplying & fixing of TV Antenna socket on Modular Plate & G.I Box including connections DSR(1.27.1+1.24.7+1.28.1) 79 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 1 or 2 ModuleDSR(1.28.1) 80 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 3 ModuleDSR(1.28.2) 81 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 4 ModuleDSR(1.28.3) 82 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 6 ModuleDSR(1.28.4) 83 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 8 ModuleDSR(1.28.5) 84 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required, 12 ModuleDSR(1.28.6) 85 Blank plate for modular plate type switch boards wherever required.DSR(1.26) 86 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 25 Sqmm 3.5 core S.I 501(J) 87 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. 25 sq. mm 3-1/2 coreS.I 503 (J) 88 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. 25 sq. mmS.I 504 (E) 89 Supply and fixing of 6Amp to 32Amp SPMCB(10KA) C Curve CAT-A4 Pole Isolator CAT-AS.I 1002(A) 90 Supply and fixing of 63Amp 4 Pole Isolator CAT-AS.I 1007(B) 91 S & F surface/Flush mounting 12ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. CAT-AS.I 1029(A) 92 Providing Drawing Connecting And Testing Of Enhanced Categoey 4 Pair Lan Local Area Network Cable 24 AWG Conductor Performance Specifide 5E U L and CUL Listed In Existing PVC Conduit .(CAT-6 Network Cable)DSR (1.53) 93 Supply & Fixing of LED Profile Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 94 Supply & Fixing of LED Profile Light Driver all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 95 Supply and fixing of 400mm Wall Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent M.R 96 Supply and fixing of 150mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent M.R 97 Supply and fixing of 250mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent M.R 98 Supply and Fixing of Deep Recess Mounting round 10 Watt COB LED Spot Light having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 99 Supply & Fixing of Hanging Light all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, EquivalentM.R 100 Providing & Fixing of Modular plate type white RJ 45 CAT 6 Data/Talephone outlet / information outlets ETL verified to meet or exceed TIA / EIA category 6 requirements, universal wiring label permitting to either T568A or T568B, UL listed,for computer networkingcomplete in all respect with cover plate, grid plate, screws, MS box, etc with connections as required with 2nos RJ-45 Data outletM.R 101 IP UNIFIED COMMUNICATION & CCTV SYSTEM WORK 102 Supply, Installation, testing and commissioning of 42U Rack complete with standard accessories Make - Dlink/Comrack 103 Supply, Installation, testing and commissioning of Cat 6 patch panel, loaded. Make - Dlink 104 Supply, Installation, testing and commissioning of modular patch cables 1m 10/100/1000 Make - AMP/Molex/DC 105 Supply,Installation, testing and commissioning of 24 port POE switch 10/100/1000. Make - Dlink/Netgear 106 Supply, Installation, testing and commissioning of Dual Band Wave Wifi 6 Access Points. Make - Grandstream/Netgear 107 Supply,Installation, testing and commissioning of cat6 Informatio0n Outlets, non PCB Pyramid type. Make - Dlink/Amp/Molex 108 Supply, Installation, testing and commissioning of Dual Face Plates with clear labeling. Make - Dlink/Amp/Molex 109 Supply, Installation, testing and commissioning of Single Face Plates with clear labeling. Make - Dlink/Amp/Molex 110 Supply, Installation, testing and commissioning of IP fixed Cameras, Network TDN IR Indoor/Outdoor Camera, 1/3 CMOS, 2 MP, 3.6 mm Fixed, 24 IR LEDs,PoE,H.264complete. Make - Dahua 111 Supply, Installation, testing and commissioning of PTZ DOME Cameras, 4MP, 2.8mm CMOS image sensor, low illuminance, 2, 12V DC/PoE power supply, Network TDN IR Indoor/Outdoor IP67 Rated tamper proof complete. Make - Dahua/Hikvision 112 FIRE ALARM WORK 113 supplying , installation , Testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. DSR-17.1.2 114 supplying , installation , Testing & commissioning of manual call boxes of MS construction in surface/recess with strainless steel chain & hammer assembly complete with glass and push button etc. as required. DSR-17.1.3 115 supplying , installation , Testing & commissionin response indicator on surface/recess Ms box having two LEDs mettallic cover complete with all connections etc. as required.DSR-17.1.5 116 supplying , installation , Testing & commissionin fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. DSR-17.1.6 117 supplying , installation , Testing & commissionin of main control and indicating panel made out of 16 SWG MS sheet to accommodete the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public adress system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all talk back master station with LED PTT ( press to talk ) push buttonfor operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/ communication suitable for 20 Nos. talk back unit-1 set. annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc, complete as required-1 set Amplifier change over switch for inter changing amplifier-1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required -1 No. Gooseneck microphone with stand and ON/OFF switch-1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required-1 set. Battery charger trickle cum boost to take complete load of fire alarm PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed mainenance free batteries-1 set. DSR-17.1.11 118 supplying , installation , Testing & commissioning of fire fighter telephone handset complete as required. DSR-17.2.17 119 CABLING & WIRINGDSR-17.5 120 supplying & laying of 2* 1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.DSR-17.5.2 121 supplying & drawing of cable fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steelconduit of following pairs, cores and size including connections and interconnections etc. as required speaker cable Two pair, 2-core , 1.5 sqmmDSR-17.5.3 122 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required DSR-17.5.4 123 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 4.5 Kg capacity CO2 type as per IS- 15683complete as per specification and fixed / install as per site condition: MR 124 Supply,Installation, Testing & Commissioning ISI marked portable type fire extinguishers of 5 Kg capacity ABC Dry Chemical powderas per IS- 15683complete as per specification and fixed / install as per site condition : MR. 125 Supply, Installation testing and commissioning of Ceiling mounted automatic fire extinguisher (Dry Chemical powder) of 10KG capacity including all fitting and accessories as per dwg and spec as complete required. MR. 126 Supply,Installation, Testing & Commissioning of 3 Nos. G.I. sand buckets painted Red Color complete with suitable size G.I. stand duly painted Red Color of suitable size to hang 3 Buckets at a time as per required specifications. MR. 127 VRV AIR-CONDITIONING WORK 128 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 41.3 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 129 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 34.9 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 130 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 28.6 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 131 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 22.2 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 132 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 19.1 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 133 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 15.9 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 134 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 12.7 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 135 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 9.5 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 136 Interconnectingrefrigerantpipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set ofindoor &outdoor units as perspecifications,all pipinginsidethe roomshallbe properlysupported 6.4 mmall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 137 Providing & Laying of Cable tray for copper pipe 300MMall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 138 Supply, Installation, testing and commissioning of Hard PVC Pipe Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 6 mm thick tubular nitrile insulation, 32 mm dia with 6 MM thicknessall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 139 Supply, Installation, testing and commissioning of Hard PVC Pipe Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 6 mm thick tubular nitrile insulation, 25 mm dia with 6 MM thicknessall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 140 Providing &fixing control cumtransmission wiring ofcopper in suitable conduits between indoorand out door unitall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 141 Supply & Laying of M S Slotted Angle for pipes and cables horizontaly and vertically along with threaded rod, nut, bolt, saddle, tie etcall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 142 Wall Chaseing as per site requirement all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 143 Making Core cutting in Walls, Beams, RCC structure as per site requirement all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 144 Supply, Installation, Testing & Commissioning of DAIKINBRANDVRV OUTDOOR UNIT MODEL 22 HP HEAT PUMPRXYQ12ARY6+RXYQ10ARY6+BHF22P1006 all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 145 Supply, Installation, Testing & Commissioning of DAIKINBRANDVRV OUTDOOR UNIT MODEL 44HP HEAT PUMP RXYQ20ARY6+RXYQ12ARY6+BHF22P1516 all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 146 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 0.66 TR + Corded Remote + Refnet, Model FXAQ20 all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 147 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 0.83 TR + Corded Remote + Refnet, Model FXAQ25all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 148 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 1.06 TR + Corded Remote + Refnet, Model FXAQ32all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 149 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 1.32 TR + Corded Remote + Refnet, Model FXAQ40all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 150 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 1.65 TR + Corded Remote + Refnet, Model FXAQ50all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 151 Supply, Installation, Testing & Commissioning of Hi wall Type Unit- 2.08 TR + Corded Remote + Refnet, Model FXAQ63all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 152 Supply, Installation, Testing & Commissioning of Round Flow Cassette Type Unit- 2.65TR + Corded Remote + Refnet, Model FXFSQ80all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 153 Supply, Installation, Testing & Commissioning of Round Flow Cassette Type Unit- 3.31TR + Corded Remote + Refnet, Model FXFSQ100all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 154 Supply, Installation, Testing & Commissioning of Round Flow Cassette Type Unit- 4.13 TR + Corded Remote + Refnet, Model-FXFSQ125all complete as per drawing, specification and directionas approved by Engineer -in-Charge. 155 One Time Lifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings (Imported Y-joints & header etc.) remote controlsof indoor units, complete as per specification and drawings, Outdoor Unitall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 156 One Time Lifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings (Imported Y-joints & header etc.) remote controlsof indoor units, complete as per specification and drawings, Hi Wall Unitsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 157 One Time Lifting, shifting, positioning, installation, testing of indoor units, outdoor units, fittings (Imported Y-joints & header etc.) remote controlsof indoor units, complete as per specification and drawings, Cassette Type Unitsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 158 Commissioning of VRV systems including topping R410A gas per site requirementsall complete as per drawing, specification and directionas approved by Engineer -in-Charge. 159 DRIVEWAY WORK 160 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.DSR-(16.83) 161 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). DSR-(16.84) 162 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. DSR-(16.91) 163 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR - 4.1.8 164 Providing & Layingof 15 mm thickHeavy duty Exterior floor tiles of approved Brand and sample in size 600 x 600 mm which will be cutted in different sizes as per app. design with 3 to 6 mm spacer offirst quality of Bell, Johnson, Kajaria or equal make, shade, colour, and pattern as app. by engineer Incharge laid over base cement mortar 1:4 mix including finishing the joint with white cementand to make the joint as perthe approved design, drawing and specification and direction of EI. MR 165 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.DSR(11.48.2) 166 FURNITURE ESTIMATE 167 Providing, Making & Fixing of Executive Wooden Court Room Dais of Size (3000Lx1200Wx750HT) MM Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 168 Table of Size - 1950W X 900D X 750HT Having Side Storage of - 900W X 450D X 750HT & Back Storage of - 1500W X 450D X 750HT & 450 Extended Top Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge Lipping on all exposed edges (Straight/Reverse waterfall edge) Support: End Legs : Powder coated Al die casted Enrich legs Modesty Panel: 18mm thk pre lam board with 2mm PVC edge lipping of 450mm Ht. Wire Management: 450mm Aluminium Flip Up and provision to mount swicthes and sockets on PVC cable dump and Vertical wire entry cover or vertebra for wire uptake from floor to cable dump The storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL (continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves, Make-Featherlite/Geeken/Hof/Equivalent 169 Table of Size - 1800W X 900D X 750HT Having Side Storage of - 900W X 450D X 750HT & Back Storage of - 1350W X 450D X 750HT & 450 Extended Top Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge Lipping on all exposed edges (Straight/Reverse waterfall edge) Support: End Legs : Powder coated Al die casted Enrich legs Modesty Panel: 18mm thk pre lam board with 2mm PVC edge lipping of 450mm Ht. Wire Management: 450mm Aluminium Flip Up and provision to mount swicthes and sockets on PVC cable dump and Vertical wire entry cover or vertebra for wire uptake from floor to cable dump The storage will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL (continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves, Make-Featherlite/Geeken/Hof/Equivalent 170 Table of Size - 1500W X 750D X 750HT Having Side Storage of - 900W X 450D X 750HT. The main table shall be made of 25mm thick PLB one side pre-laminate board confirming to IS-14587:1998. Soft closing access flap with in-built power box to be provided on work surface for wire management. Return table Work Surface should be made of 25mm thick PLB one side pre-laminate board confirming to IS-14587:1998. PLB will be E1-P2 grade and approved shade. Confirming to IS-12823:1990. 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The edge band material should have Shore D hardness of 79± 4. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification confirming to ASTM D 4499 standards for viscosity and thermal stability. The edges should be PVC Edge banded with matching finish or have an option of reverse water fall edges.Modesty Panel shall be made of 18mm thick PLT both sides pre-laminate board confirming to IS-14587:1998.The height of modesty shall be 450 mm.The modesty panel will be connected to the main table by 2 nos special Aluminum extruded brackets. The modesty will be fixed 150 mm from the edge of the table. • Cable management: The table will be provided with suitable grommet hole. Legs and Supports:- The MS supports are made of 55 x55mm diamond shape loop leg ERW tubes- 16g with levelers to cater for floor undulations- +/- 20 mm. ERW Tube confirming to IS 4923 : 1997 – 16g. Main leg members will be connected through a horizontal member size 1.6mm thk, 60x40 cold formed ERW tube confirming to IS 4923: 1997. The vertical and the horizontal tubes will be welded with CO2 MIG welding process confirming to IS 816 and ISO 9692-2. The leg will be fabricated using Argon & Co2 gas mixture on a Robotic welding machine to ensure adequate welding strength with consistency.• The legs will be connected with Cross beams to take care of the bending stress catering up to 1800 mm length and up to 900 mm depth of the work surface. Finish:- All metal components & aluminum die cast parts will be powder coated by Nano ceramic surface treatment process compiled to a Bend test-ASTM D3451 – 06, Adhesion -DIN EN 14901 Salt spray test- DIN EN ISO 9227, which is non-hazardous, environmental friendly and will have uniform powder coating thickness of 50-60-micron thickness.Wire Management: Make-Featherlite/Geeken/Hof/Equivalent 171 Providing, Making & Fixing of Wooden Table of Size (1350Lx675Wx750HT) MM Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 172 Providing, Making & Fixing of Wooden Linear Workstation Table Having Keyboard Tray & Cable Manager Made of 1 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 173 Liner Workstation of Size:- 1350W X 600D X 750HT AND 300HT HEIGHT Specifications: Table Top - 25mm thick Pre Lam particle board with 2mm edge lipping on all exposed sides. Support - MS powder coated diamond shape leg of 55X55mm size with die cast connectors and supporting MS cross beams. Main Screen:- Aluminum anodised 30mm scree n with fabric magnetic and glass marker tiles. Privacy Screen:- 6mm thick acrylic screen on studs. Wiremanagement - 450mm metal flip up with provision to mount switches and sockets on MS cable tray and vertical wire entry cover between the intermeidate leg for power and data. Model - MAX-1 Make-Featherlite/Geeken/Hof/Equivalent 174 Providing, Making & Fixing of Wooden Linear Printer Table,Made of 1 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized. 175 Providing And Fixing of Confference Table Made 0f 19MM thick ply board,Top in 3 layers and virtical drop 3 Lair 19MM ply board. All the surface to be cladded with 4MM thick Veener And S.S Fram square section 302 grad frame. All the edges to be lipped with 4MM Veneer polished in matching colour.As per the design. as per E/I. (Greenply/Luxe or Equivalent ISI Make) Customized 176 Providing, Making & Fixing of Wooden Witness Box of Encloser Size (1050Lx900Dx1050HT) MM Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 177 Providing, Making & Fixing of Back Storage of Size (3000Lx450Wx700HT) Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge.Customized 178 Providing, Making & Fixing of Back Storage of Size (1800Lx450Wx700HT) Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 179 Providing & Fixing of Wooden Storage, Particle Board Structure, (1500x450x900), Model-Storage-9, Make-Geeken, all complete as per design approved by E/I & Architect Incharge. 180 Side Storage of Size 900Wx450Dx750HT will be made in 18 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. The PLB will be confirming to E-1 Grade as per the JIS A 5905-2003 standards and approved shade confirming to IS-12823:1990.The back of storage will be made in 9 MM PLB (Pre laminated board) with the density of 680kg/m³ and 18 mm thick one side pre-laminate board confirming to IS 12406 : 2013. Surface: CPL ( continuous pressure laminate) in 0.5mm thickness in melamine finish. Storgage will be provided with edge banding 2 mm thick PVC edge band will confirm to DIN 68861 for resistance to clearers. The Hot melt glue used for fixing the PVC edge band should have ISO 9001- 2015 quality certification and confirm to ASTM D 4499 standards for viscosity and thermal stability. The edge band material should have Shore D hardness of 79± 4. storage will have two adjustable shelves making 3 compartments.The shutters are fitted with auto closing hinges.Central locking system , levellers & other necessary hardware are priovided.Handles will be hand grooved, Make-Featherlite/Geeken Equivalent. 181 Providing, Making & Fixing of TV Pannel of Size (2100Lx450Wx750HT) Made of 2 Layers of 19MM Board with All Edges to be Lipped with Teak Wood Beading & All Outside Exposed Surface To Be Finished With 4MM Veneer which shall be Melamine Polished & Inner Side To Be Finished with 1MM Laminate, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge. Customized 182 High Back Chairs Seat and back is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Imported T-nuts and revited in to the wood.Gaslift - Class 4 tested -ANSI BIFMA performance standards.Castors - Twin Castors 50mm dia castors compling to ANSI / BIFMA X 5.1 – 2002.The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength.Tested prudently and rigorously as per ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards.Upholstery: Seat Cushion with pre moulded foam having leatherette tapestery of 50 - 60 density Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Distinctively and characteristically designed tilt mechanism offering a very smooth and fluidic reclining motion with tension adjust knob and importantly offering seat to back recline ratio of 3:7, optimal for good back support.Multilock mechanism is fabricated from CR Sheets, undergo through CO2 welding process imparting uniform surface finish and tensile strength. The components are processed with high degree of precision and care so as to assemble with other parts in perfect harmony to give smooth and effortless reclining experience. Tension springs are made out Grade II material conforming to Indian Standards. Also provided with release levers for locking mechanism and height adjustment of seat. Mechanism aides to operate the height adjustment, and has been equipped with 3 locking positions, back rest “ Return Prevention” function. Back Frame is inserted with leathertte tapestery cushion & Adjustable Lumbar Support.Tension control is below the Seat.Moulded polyurethene Arms confirming to IS 7078 with steel inserts for long Moulded self skinned polyurethene Arms confirming to IS 7078 with steel insets for long life. one way adjustable - Height Adjustable.Seat is duly upholstered with approved fabric. Chair will have adjustable headrestChair Should be BIFMA Certified.Seat: Depth- 51.5 cm Width- 44.5 cm Dimensions: Width- 51.5 cm Depth- 53.5 cm Minimum Height- 99.5 cm Maximum Height- 108.5 cm Minimum Seat Height- 44.5 cm Maximum Seat Height- 52.5 cm Width (Arm to Arm)- 66 MODEL, Chair should be BIFMA and Green Guard certified.:- AMAZE HB,Make-Featherlite/Geeken/Hof/Equivalent Model-GA 5003 all complete as per design approved by E/I & Architect I 183 Medium Back chair Having Base: Nylon Base- The 640mm dia (26 inches) five pronged base is made out of GF nylon – Reinforced with bottom ribbing for additional buttress and strength. Tested prudently and confirming to ANSI/BIFMA X5.1-2011 General Purpose Office Chair Standards. The base shall be 67 cm pitch-center diameter -77 cm with castors. MS ring will be insert molded for better grip in the swaged taper. Castors: Twin Castors 50mm dia complying to ANSI / BIFMA X 5.1 – 2002. Castors will be made in PP.The axle pin will be rust protected- Zinc pacified. The pin should be designed to have push fit with lock ring. RoHS compliant castors. Gas lift: Standard Gas lift 100 mm stroke with pneumatic height adjustment as per the seat height criteria.- Class 4 as per ANSI BIFMA performance standards. Possibility to increase the seat height if required with Gas lift stroke- 110 -125 mm. Mechanism:Centre Tilt Mechanism:compact and stable with 8″ x 6″ mount holes as per European Standard. Initial seat angle of 3 degrees and full recline angle of 20 degrees for ergonomic comfort. Provided with common leverfor locking and up/down adjustment and horizontal movement of the lever to engage and disengage lock at upright positionLever provided for rotational movementto operate gas lift and adjust chair height to user specification. Full length plastic knob provided to cover lever bar giving better aesthetical appeal to the mechanism. Knob provided to adjust spring tension to suit individual user in order to ensure maximum chair comfort. Arms:Fixed Arms Injected molded arms- polyurethane 20% GF nylon. The polypropylene arms will have steel inserts. The arm profile should blend with the back profile without gap. Seat: Seat Height- 450-540mm with hydraulic height adjustability of 90-100mm. Seat Width & Height- Size of the chair shall be -Back: 45.0cm. (w) x 59.0cm.(H) .Seat: 48.0cm (w) X 49.0cm.(D). Chair back should be connected to the Polyurethane arms for achieving comfortable seating posture.Effective back height from Seat - 560mm, Ply wood- 12 mm thick with 7 ply. Fire retardant type exterior grade phenol formaldehyde bonded. It will be hot pressed ply - conforming to I.S.I. 5509. The arm and back shall be fixed together to the seat with Allen bolts.The bolts will be screwed to the “T” nuts fixed to the plywood seat.Fabric: Upholstery:Seat & Back are duly upholstered with approved fabric. The back should have the option of mesh back AN-70 (black) and AN-75(grey). GSM for mesh 340. No flaming or progressive smolderingwithin one hour of placement of the cigarettes. Fire rated fabric confirming to BSEN 1021 and IS 15061-2012 Foam: Seat cushion with pre molded foam of 50 - 60 density in the shape of plywood.Density -- 52 kg/m3, Hardness -- 12.6kgf at 25%- Back cushion- density- 32g/sq in. Back:Mesh back on injected molded PP with 30% GF nylon. The back should have the option of mesh or fabric back. The mesh will be GSM 340 grade. . ALPHA MB, Make-Featherlite/Geeken Equivalent. 184 Fixed Leg Chair Made of The frame is made out of 25.4mm tube of 16 gauge tube confirming to IS-7138-1973, Welded by Co2 welding process for uniform surface finish and higher tensile strength perforation on the sheet is of uniform 2.5mm dimension and gives good ventilation.High quality hardware conforming to Hardness 38-44 and tensile strength – 1300 n/mm. IS 1363-1967.Seat is made out of 12mm molded hot pressed plywood in ergonomic shape fitted with Japanese T-nuts and riveted in to the plywood.Set and backUpholstery: Cushion with pre-moulded foam of 50 - 60kg/m3 density in the shape of plywood. Density -- 52 kg/m3 Hardness -- 12.6kgf at 25%.Injection moulded polypropylene armrests.Leatherette cusion Back on Frame. Back is injected moulded PP.Seat and back are duly upholstered with approved Leatherette. AMAZE VA, Make-Featherlite/Geeken/Hof/Equivalent 185 Providing & Fixing of 3 Seater Sofa, Aluminium Arm And Leg, Powder Coated Cross Beam, Metal Insert PU Seat Back Size in mm - 1625(L) X660(D) X 870(H) Having 3 Seater With 4 Arm, Model-Fly-2, Make-Featherlite/Geeken/Hof/Equivalent, all complete as per design approved by E/I & Architect Incharge. 186 Providing, Making & Fixing of High Back Chair As per Design Approved made of teak wood having high density foam of sleepwell brand, upholstered in approved fabric/leatherrete. Wooden part to be finished in melamine polish, Complete In All Respect As Per Drawing, Specification Approved By Architect/ Engineer In Charge.Customized 187 GUARD-1 ROOM WORK 188 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil , DSR-2.8.1 189 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR-4.1.8 190 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. DSR-2.27 191 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):1).Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of300mm including excavation channel along the wall & rodding etc. complete: 2).Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. 3).Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. 4).Treatment of existing masonry using chemical emulsion@ one litre per hole at 300mm interval includingdrilling holes at 45 degree and plugging them withcement mortar 1:2(1 cement : 2 coarse sand) to the full depth of the hole. 5).Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/Lindane(in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downwardangle of 45degree at 150mm centre to centre and sealingthe same.All with With chlorpyriphos/Lindane E.C. 20% with 1% concentration. DSR-2.35.1+2.35.2+2.35.3+2.35.3+2.35.4+2.35.5 192 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum.Concrete of M25 grade with minimum cement contect of 300 kg/cum (For Foundation) DSR-5.33.1.1 193 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Column) DSR-5.33.2.1 194 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Beam) DSR-5.33.2.1 195 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Slab) DSR-5.33.2.1 196 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Lintel) DSR-5.33.2.1 197 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.1.1 198 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.4.1 199 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R.-4.10 200 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approv quality using 1.7 kg per square metre on damp proof course after cleaning the surface w brushes and finally with a piece of cloth lightly soaked in kerosene oil. D.S.R.-4.13 201 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more DSR-5.22.6 202 12 mm Cement plaster of mix.1:4 (1 cement: 4 course sand) DSR-13.4.1 203 15 mm cement plaster in single coat on rough side of single or half brick wall 1:4 (1 cement: 4 course sand) DSR-13.5.1 204 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1) cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deepThe whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-ChargeWith average thickness of 120 mm and minimum thickness at khurra as 65 mm DSR-22.7 205 Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns. DSR-5.9.1 206 Centering and shuttering including strutting, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform. DSR-5.9.3 207 Centering and shuttering including strutting, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR-5.9.5 208 Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, piers, abutments, pillars, posts and struts. DSR-5.9.6 209 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. MR 210 GUARD-2 ROOM WORK 211 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil , DSR-2.8.1 212 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR-4.1.8 213 Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. DSR-2.27 214 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):1).Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of300mm including excavation channel along the wall & rodding etc. complete: 2).Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. 3).Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. 4).Treatment of existing masonry using chemical emulsion@ one litre per hole at 300mm interval includingdrilling holes at 45 degree and plugging them withcement mortar 1:2(1 cement : 2 coarse sand) to the full depth of the hole. 5).Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/Lindane(in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downwardangle of 45degree at 150mm centre to centre and sealingthe same.All with With chlorpyriphos/Lindane E.C. 20% with 1% concentration. DSR-2.35.1+2.35.2+2.35.3+2.35.3+2.35.4+2.35.5 215 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level, Concrete of M25 grade with minimum cement content of 330 kg /cum.Concrete of M25 grade with minimum cement contect of 300 kg/cum (For Foundation) DSR-5.33.1.1 216 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Column) DSR-5.33.2.1 217 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Beam) DSR-5.33.2.1 218 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Slab) DSR-5.33.2.1 219 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level,Concrete of M25 grade with minimum cement content of 330 kg /cum (For Lintel) DSR-5.33.2.1 220 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.1.1 221 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement: 4 coarse sand) D.S.R.-6.4.1 222 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 12.5mm nominal size derived from natural sources) D.S.R.-4.10 223 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approv quality using 1.7 kg per square metre on damp proof course after cleaning the surface w brushes and finally with a piece of cloth lightly soaked in kerosene oil. D.S.R.-4.13 224 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more DSR-5.22.6 225 12 mm Cement plaster of mix.1:4 (1 cement: 4 course sand) DSR-13.4.1 226 15 mm cement plaster in single coat on rough side of single or half brick wall 1:4 (1 cement: 4 course sand) DSR-13.5.1 227 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1) cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement 4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deepThe whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-ChargeWith average thickness of 120 mm and minimum thickness at khurra as 65 mm DSR-22.7 228 Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns. DSR-5.9.1 229 Centering and shuttering including strutting, propping etc. and removal of form work for:Suspended floors, roofs, landings, balconies and access platform. DSR-5.9.3 230 Centering and shuttering including strutting, propping etc. and removal of form work for:Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR-5.9.5 231 Centering and shuttering including strutting, propping etc. and removal of form work for:Columns, piers, abutments, pillars, posts and struts. DSR-5.9.6 232 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. MR 233 LT PANNEL DG SET WORKS 234 DG Set- BACKSIDE OF THE BUILDING 235 Supply of 250 KVA DG Set Cummins/ Mahindrol 236 b DG set installation and associted works 237 LT CUM AMF PANEL - ELECTRICAL ROOM 238 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction extendable type LT CUM AMF Panel, suitable for operation on 415 ±10%volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 2mm thick for frame work and 1.6mm covers (non load bearing), 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extensible type TPNAluminium bus bars of high conductivity, SMC bus bar supports, with bottom base channel of section not less than ISMC 75mm, fabrication shall be done in transportable sections, entire panel shall have a common G.I. earth bus bar to switch gears with required size of Alum. bus bars and inter-connectionwith solid copper conductor wires / aluminium strips, neutral links, including control wiring with 1.5 / 2.5sqmm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted with the following switch gears as per drawingandtechnical specifications etc. 239 INCOMER FOR TRANSFOMER4 No. 240 400A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 241 Standard extended rotary handle for EasyPact CVS 400/630A SCHNEIDER/ABB/L&T 1 No. 242 Spreader Links (Set of 4) 4P for EasyPact CVS 400A SCHNEIDER/ABB/L&T 2 No. 243 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 244 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 245 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 246 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 247 INCOMER FOR DG1 No. 248 400A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 249 Standard extended rotary handle for EasyPact CVS 400/630A SCHNEIDER/ABB/L&T 1 No. 250 Spreader Links (Set of 4) 4P for EasyPact CVS 400A SCHNEIDER/ABB/L&T 2 No. 251 Multifunction Meter-Load Manager with RS485 port, Parameters: V, A, F, PF, W/VA, Wh /VAh, Runhrs, Onhrs & Interupts & Suppression Current (5 to 99 mA), Acc. Cl: 1.0, 3Ph, Operating voltage: 80 to 480V AC, Size: 96X96, Model: EM6436H CONZERV/SECURE 1 No. 252 400/5A Acc.Cl: 1 10VA Resin Cast Ring Type Current Transformer, Round Dia: 55mm PROCOM 1 No. 253 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 254 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 2 No. 255 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 256 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 257 SERVO BY-PASS ARRANGEMENT2 No. 258 400A 4P Front operated By-pass Switch with External Handle, bridging bars & Interphase Barrier, Type: SIRCOVER BYPASS SOCOMEC/C&S/HPL 1 No. 259 CHANGE OVER SECTION FOR PHASE CORRECTION2 No. 260 400A 4P ATS with bridging bars,Type: ATyS r SOCOMEC/C&S/HPL 1 No. 261 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation1 No. 262 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 263 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 264 Phase Sequence Relay, 3Ph-3W, Protection: Phase failure, Phase sequence, Phase asymmetry, DIN rail mount, 1C/O, Supply Voltage: 154V-500V AC (L-L), Model: 800PSR1 No. 265 14 PIN MINIATURE RELAY WITH BASE 230V AC 1 No. 266 AMF LOGIC WITH CONTROL MCBs1 No. 267 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 9 No. 268 10A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 269 10A 2P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 No. 270 On Delay / Interval Timer, Time Range: 3 Sec to 60 Mins, 2 C/O, Voltage: 20 to 240V AC & 12to 240V DC, Type: 800XA3 No. 271 Digital Voltage Protection Relay, 3Ph-3W/ 3Ph-4W, Protection: Under / Over voltage, Phase failure, Phase sequence, Phase asymmetry, Under / Over frequency, Neutral loss, 2 x 1C/O, Supply Voltage: Self powered, Model: 900VPR2 No. 272 14 PIN MNIATURE RELAY WITH BASE 3 No. 273 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 2 No. 274 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 275 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 276 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 12V AC/DC C&S/VAISHNO 2 No. 277 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 12V AC/DC C&S/VAISHNO 2 No. 278 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 12V AC/DC C&S/VAISHNO 1 No. 279 Green 22.5mm Flush Type Spring Return Non-Illuminated (Metallic) Push Button, Contacts: 1NO C&S/VAISHNO 1 No. 280 Red 22.5mm Flush Type Spring Return Non-Illuminated (Metallic) Push Button, Contacts: 1NC C&S/VAISHNO 2 No. 281 6A 1P 2Way Local - Remote/ Auto-Manual Switch with Center OFF, 60 Deg. Operation1 No. 282 12 ,10A BATTERY CHANGER1 No. 283 EMARGENCY 284 BUSCOUPLER1 No. 285 400A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 286 Standard extended rotary handle for EasyPact CVS 400/630A SCHNEIDER/ABB/L&T 1 No. 287 Spreader Links (Set of 4) 4P for EasyPact CVS 400A SCHNEIDER/ABB/L&T 2 No. 288 AC3: 250A AC1: 300A 3P Power Contactor, Coil: 220V AC, Type: LC1E SCHNEIDER/ABB/L&T 1 No. 289 Auxiliary Contact Block, Front Mounting, Contacts: 1NO+1NC for LC1E06-E630/LC1E0600-LC1E9500 SCHNEIDER/ABB/L&T 1 No. 290 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 291 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 292 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 293 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 294 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 No. 295 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 5 No. 296 BUS BAR No. 297 400A TPN, 50KA aluminium bus bar with coloured heat shrinkable insulated sleeve. No. 298 Outgoing 299 OUT GOING 250A MCCB1 No. 300 250A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 4 No. 301 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 4 No. 302 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A SCHNEIDER/ABB/L&T 8 No. 303 VAF, PF Meter, Acc. Cl: 1.0, Model: DM6100 CONZERV/SECURE 1 No. 304 250/5A Acc.Cl: 1 10VA Resin Cast Ring Type Current Transformer, Round Dia: 45mm PROCOM 1 No. 305 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 2 No. 306 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 307 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 No. 308 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 No. 309 OUT GOING 200A FP MCCB2 No. 310 200A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS1 No. 311 Standard extended rotary handle for EasyPact CVS 100/160/250A1 No. 312 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A2 No. 313 OUT GOING 160A FP MCCB6 No. 314 160A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 315 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 1 No. 316 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A SCHNEIDER/ABB/L&T 2 No. 317 OUT GOING 100A FP MCCB2 No. 318 100A 4P 25kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 No. 319 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 1 No. 320 Spreader Links (Set of 4) 4P for EasyPact CVS 100A SCHNEIDER/ABB/L&T 2 No. 321 OUT GOING 63A FP MCCB2 No. 322 63A 4P 10kA C-Curve MCB,Type: xC60 SCHNEIDER/ABB/L&T 2 No. 323 75KVAr APFC PANEL - ELECTICAL ROOM 324 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction APFC Panel, fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 1.6mm thick for frame work and 1.6mm covers (non load bearing), 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade. 325 APFC PANEL INCOMER 1 Nos. 326 200A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 Nos. 327 Standard extended rotary handle for EasyPact CVS 100/160/250A SCHNEIDER/ABB/L&T 2 Nos. 328 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A SCHNEIDER/ABB/L&T 1 Nos. 329 5 Steps 240V AC Power Factor Controller Relay with 3CT, 3PH-4W, Type: BR50001 Nos. 330 Multifunction Meter-Load Manager with RS485 port, Parameters: V, A, F, PF, W/VA, Wh /VAh, Runhrs, Onhrs & Interupts & Suppression Current (5 to 99 mA), Acc. Cl: 1.0, 3Ph, Operating voltage: 80 to 480V AC, Size: 96X96, Model: EM6436H CONZERV/SECURE 9 Nos. 331 200/5A Acc.Cl: 1 10VA Resin Cast Ring Type Current Transformer, Round Dia: 30mm PROCOM 1 Nos. 332 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 333 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 3 Nos. 334 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 4 Nos. 335 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 Nos. 336 CAPACITOR BANK SECTION Nos. 337 25KVAR BANK2 Nos. 338 100A 3P 25kA MCCB,TMD Release,Type: EasyPact CVS SCHNEIDER/ABB/L&T 1 Nos. 339 Spreader Links (Set of 3) 3P for EasyPact CVS 100A SCHNEIDER/ABB/L&T 2 Nos. 340 25kVAr 3Ph Heavy Duty PhiCap-Cylindrical 440V AC Capacitor EPCOS/SCHNEIDER 1 Nos. 341 AC3: 50A AC1: 80A 3P Power Contactor, Coil: 220V AC, Aux. Contact: 1NO+1NC, Type: LC1D SCHNEIDER/ABB/L&T 1 Nos. 342 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 343 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 Nos. 344 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 Nos. 345 10KVAR BANK2 Nos. 346 63A 3P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 Nos. 347 10kVAr 3Ph Normal Duty PhiCap-Cylindrical 440V AC Capacitor EPCOS/SCHNEIDER 1 Nos. 348 AC3: 25A AC1: 40A 3P Power Contactor, Coil: 220V AC, Aux. Contact: 1NO+1NC, Type: LC1D SCHNEIDER/ABB/L&T 1 Nos. 349 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 350 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 Nos. 351 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 Nos. 352 5KVAR BANK1 Nos. 353 32A 4P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 1 Nos. 354 5kVAr 3Ph Normal Duty PhiCap-Cylindrical 440V AC Capacitor EPCOS/SCHNEIDER 1 Nos. 355 AC3: 16A 3P Power Contactor, Coil: 220V AC, Aux. Contact: 1NC, Type: LC1K SCHNEIDER/ABB/L&T 1 Nos. 356 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC C&S/VAISHNO 1 Nos. 357 Green Indicating Lamp 22.5mm with Integrated LED, Voltage: 220V DC C&S/VAISHNO 1 Nos. 358 6A 1P 10kA C-Curve MCB,Type: K60H SCHNEIDER/ABB/L&T 2 Nos. 359 LTDB - 2 ON EVERY FLOOR 360 Supplying, Installation, Testing and commissioning of dust, damp and vermin proof cubicle free floor, indoor type factory built sheet steel enclosed modular bolted construction LTDB, fabricated out of suitable sized square tubular section andcoveredwith CRCA sheet steel of 1.6mm thick for Enclosure, 2mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade. 361 160A 4P 36kA MCCB,TMD Release,Type: EasyPact CVS 362 Standard extended rotary handle for EasyPact CVS 100/160/250A 363 Spreader Links (Set of 4) 4P for EasyPact CVS 160/250A 364 Red Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC SCHNEIDER/ABB/L&T (1.0 Nos) 365 Yellow Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC SCHNEIDER/ABB/L&T(1.0 Nos) 366 Blue Indicating Lamp 22.5mm with Integrated LED, Voltage: 240V AC SCHNEIDER/ABB/L&T (2.0 Nos) 367 6A 1P 10kA C-Curve MCB,Type: K60H C&S/VAISHNO (3.0 Nos) 368 CABLES 369 Supply of 185SQMM 3.5 core LT aluminum PVC Insulated armoured cables. - FROM MAIN TRANSFORMER TO LT PANEL 370 Supply of 95SQMM 3.5 core aluminum Armoured - MAIN LT PANEL TO LTDB 371 Supply of 2.5SQMM 2 core Copper Armoured - BOUNDRY WALL LIGHTS CONNECTIONS 372 END TERMINATION - MAIN LT PANNEL & LTDB 373 185Sqmm End termination with materials 374 95Sqmm End termination with materials 375 EARTHING - OUTSIDE ELECTRICAL ROOM 376 GI Earthing 377 Copper Earthing 378 Supply & Laying of 25X3 GI strip with nut bolt & washers 379 LABOUR CHARGE ( FOR INSTALLATION OF LT PANEL, APFC PANEL, LTDB & LAYING OF CABLE) 380 WATER PROOFING & RAINWATER WORKS 381 Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth , Pipes 80 mm to 300 mmdiameter DSR - 2.10.1.2 382 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. DSR - 12.22 383 Providing and fixing of water proofing layer on the terrace on the exsisting floor of the terrace without removing the exsisting layer of PCC only cleaning included as per specMR 384 Constructing masonry Chamber 60X60X75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR - 18.33.1 385 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ringconforming to IS: 5382 leaving 10mm gap forthermal expansion. - 110 MM DSR - 12.41.2 386 Providing of open drainAR 387 Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. Providing & fixing of door / windows grill. DRS -10.25.2 388 Landscraping work 389 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR-(2.31) 390 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR - 4.1.8 391 Providing & Layingof 15 mm thickHeavy duty Exterior floor tiles of approved Brand and sample in size 600 x 600 mm which will be cutted in different sizes as per app. design with 3 to 6 mm spacer offirst quality of Bell, Johnson, Kajaria or equal make, shade, colour, and pattern as app. by engineer Incharge laid over base cement mortar 1:4 mix including finishing the joint with white cementand to make the joint as perthe approved design, drawing and specification and direction of EI. MR 392 Grouting the joints of flooring tiles having joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.DSR(11.48.2) 393 Brick Workin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) DSR-6.4.2 394 supply and installation of steel bolads at propoer distance as directed by the architect inchargeMR 395 Supply and installation of stone benches as per layout and designas directed by the architect inchargeMR 396 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement, 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage wherever required complete etc. as per direction of Engineer- in- charge ( length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by Engineer - in - charge). DSR-16.69 397 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. DSR- 10.16.1 398 CIVIL-FACADE ESTIMATE 399 Dismentling of RCC work i/c stacking of dismantled material as directed by EI with in distance 50 Mtrs.DSR 15.3 400 Dismentling of RB work i/c stacking of dismantled material as directed by EI with in distance 50 Mtrs.DSR 15.4 401 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area Beyond 3 sq.DSR 15.12.2 402 Dismentling of existing plasterand i/c stacking of dismantled material as directed by EI with in distance 60 mtrsDSR 15.56 403 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.DSR 15.60 404 12 mm cement plaster with 1:4 cement & coarsesand of 1.25 FMin single coatof single or half brick wall for interior plastering upto floor two level. DSR 13.4.1 405 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand) DSR 14.1.2 406 Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinthlevel :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) DSR 4.1.8 407 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once for every month for duration of scaffolding (Maximum 3 Months).DSR - 14.72 408 Providing & Fixing of Cluster Stone Brick Stamping of Size (8.46x2.36) & 13MM (Approx) Thick having Super Hard outer shell on Vertical Surface with uncoloured Adhesive FS complete as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. MR 409 Supply&Fixingofwindowsmadefrommulti chambered UPVC profiles of minimum 60/108 mm thicknessof (Wintechmakeorequivalent)in natural from stailized for heat, light, impact & UV radiation. The UPVC profiles should be reinforced withgalzvanizedsteelprofilesofdesigned thickness.Floatglassofapprovedcolourin 4/5/6/8 mm or as desired by the costumer shall be fixed with heveled beads. All openable / sliding sashes shall be having grey/black colored weather seal fitted in continuous lenghts made from bubble PTV Rubber & side Hung with 90L openin friction syats of rust proof stainless steel with provision of multipoint lockng system (casement only) made from Espag rods (coated steel) all handle shall be made from die Cast zinc alloy in white finish only as per desigh, drawings, specification & as approved by Architect/Engineer Incharge. M.R 410 Providing & Fixing of Roller Blinds with Hand Rail of approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 411 Providing & Fixing of Zebra Blinds with Hand Railof approved shade as per drawing & specificationas approved by Engineer -in-Charge. M.R 412 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. DSR 25.1 413 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel (Making Louvers & Groves) Cladding, with open grooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including:Structural analysis & design and preparation of shop drawings for pressure equalization or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design ) Providing, fabricating and supplying and fixing panels of aluminum composite panel cladding in Pan shape of approved shades made out of 3mm thick aluminum composite panel material consisting of 2.40mm thick non toxic low density polyethylene virgin core sandwiched between two Aluminum coated sheets (each 0.3mm thickof AA 3105 Alloy grade). The aluminum composite panel cladding sheet shall be coil coated, with Kynar 500 based/hylar 5000PVDF / Lumiflon based fluoropolymer resin lead 4.10 to 4.30 kg per sqm., nuts, bolts, washers, cleat drawings.DSR 25.2 414 Scraping of old white or colour wash including disposal of refuse as directed by EI with in distance 60 mtrs.DSR 13.88 415 Providing & Applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over plastered surface to prapare the surface even & smooth complete.DSR 13.80 416 Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 DSR 13.45.1 417 ELECTRICAL WORK ESTIMATE 418 Supply and fixing of Decorative 45 Watt LED Post Top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 6565 Make-Klite, all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-ChargeMR 419 Supply and fixing of Decorative small decorate light withdirect dim light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to , all complete as per drawing, specification and directionas approved by the Architect/ Engineer -in-ChargeMR 420 Supply and fixing of 200 AMP MCCB Box with load diverter for the connections to the guard room for the landscape lightsMR 421 Providing and laying of 2.5MM 3.5 core copper armored cable for street light connections as per specs MR 422 Providing and Fixing of RCC round base with foundation of bolts and spces for the 45 Watt LED Post Top indirect light luminaireMR 423 BOUNDRY WALL WORK RATE ANALYSIS FOR (2.5MTR) 424 Brick Workin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) DSR-6.4.2 425 Lime plaster 1:1:1 (1 lime putty : 1 surkhi : 1 finesand) INTACH SOR 2016 9.2.1 426 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DRS -10.25.2 427 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture DSR - 13.48.3 428 Supply and fixing of decorative plate on ms grill ralling with cold pressed impresion of fish and andaaz awadh as per specs.MR
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
39.
Agriculture #9433008 Technical Bid
Supply Of Electrical General Items , Push Button Element 1No+1Nc Vaishno Make , Single Phase Tester Taparia Make Size 6 , Req/Isulator For Cane Unloader Size 6” , Shaklo Insulator For Ltline Protection , Connector Link Elmax Make Size 6 Mm , Dobut Size 16 Mm , Dobut Size 25 Mm , Dobut Size 35 Mm , Dobut Size 50 Mm , Pvc Steel Grip + Tape Size 3/4” Length 10 Mtr , Cotton Tape Size 3/4” , Porceline Kit Kat Standard 20Amp. 240Volt , Dobut 32Amp. 240Volt , Dobut 32Amp. 440Volt , Bowel Element 750 Watt , Soldring Iron 35W , Soldring Paste , Soldering Wire 0-10 Swg Bharati 80%& 20% , C.R.C. 2-26 (300 Ml) , Insulatingvarnish Dr.Back Make Elmoluft 1A , Varnish Bectrol Grey / Red , Thinner Dr. Backmake 218 For V-155 , Dobut 205 For V-155 , Dobut 234 For V-155 , Havels Force-10 Exhaust H.D. Fan 18”, 250V , 1500 Rpm. Single Phase , Dobut18” , 250V , 1500 Rpm. Three Phase , Do But 12” , 250V , 1500 Rpm. Single Phase , Do But 24” , 240V , 1000 Rpm. Single Phase , Dobut 24” , 240V , 1000 Rpm. Three Phase , Blower Fan , Push Button Green /Red Vaishno Make , Push Button Element Vaishno Makeno & Nc , Push Button Station Colour Light Grery , Bulbs 24V 60 Watt , Bulbs 24V 100 Watt , Fuse Base Vaishno Make 250Amp. , Do But400 Amp. , Do But630 Amp. , Condensor 4 Mfd, 440 V, Usha /Asian Make , Do But 2.5 Mfd , Do But 3.15 Mfd , Condensor 8 Mfd , Do But 10 Mfd , Do But 20 Mfd , Do But 33 Mfd , Milimax Paper 7 Mile , Milimax Paper 5 Mile , P.T. Holder 100 Watt Anchor Make , S.C. Holder 100 / 200 Watt Jyoti/National Make , Do But 300 / 500 Watt , Combination Plier 8” Taparia Make , Tube Side Holder For 40 W , Tube Side Holder Backlite Stand Single/Double , Three Pin Porceline Holder For 125 Hpmv Lamp , Tube Lite Rotary Holder Base (Single Fitting) , Tube Lite Rotary Holder Base (Double Fitting) , Indicator Lamp 40 Lad , Change Over Switch Standard 200 Amp 440V , Change Over Switch Standard 400 Amp 440V , Do But 630Amp 440V , C.T.C. 400 Ml , Sc Holder 300 Watt For Sodiam Hanging Light , Pvc Motor Cooling Fan I H.P. , Do But 03 H.P. , Do But 05 H.P. , Do But 7.5 /10 H.P. , Do But 15 H.P , Do But 20 H.P , Do But 25 H.P. , Do But 30 H.P. , Empire Tape 1” Of Mt , Empire Tape 3/4” Of Mt , Glass Tape 1” Ofmt , Glass Tape 3/4” Ofmt , Semi Conductor Fuse Gec Make 1000/850/630/300/250A,600V , Potententio Meter 2Ko-5410-10 Pankaj/Pawan Make 2K5-500W , Fuse Carriar 125Amp Vaishno Make , Timer Em-2000,4-120 Sec 240 Vac, 50Hz , Fuse Link Type Tis 63 Amp , Fuse Link Typetia 32 Amp , Glass Fuse20mm , 01Amp To 10Amp. , Element 250Watt , Do But 150Watt , Semi Conductor Fuses 1250 Amp., 660V, 170L 7035 38T/50 90415 Ty Power Silicon/Bushmen Denmark Make , Do460amp. 660V, Gsmj/170M 5239-500 Mp.1000V , Do 460Amp. 660V, Gsmj/170M 5239-500 Amp.1000V , Semi Cunductor Fuse 700 Amp., 690 Volt, 170 M 6111 Bushmen Denmark Make , Diode Rectifier 321Ur 100G, Reverse / Forward (Ruttonshaw) , Diode40hm 120G, Reverse / Forward(Ruttonshaw) , Pvc Connection Elemax Make Cts750v 35A , Do But 25A , Do But 16A , Do But 10A , Limit Switch415v,Llgs Bch Make , Rpm Meter 0-600Vdc ,1950Rpm,Fsd 1Mile Amp 96 X 96 With Calibration Card , Automatic Voltage Regulator With Time Delay , Lt Control Switch With Changeover3la202-1A , Digital Multimeter Meco Make , Thyrister St -330C14co Itally Make , Proximaty Switchs-30V , Glass Sleeve Size 1 Mm , Glass Sleeve Size 2 Mm , Glass Sleeve Size 3 Mm , Glass Sleeve Size 4 Mm , Glass Sleeve Size 5 Mm , Glass Sleeve Size 6 Mm , Glass Sleeve Size 8 Mm , Glass Sleeve Size 10 Mm , Glass Sleeve Size 12 Mm , Glass Sleeve 25 Mm , Glass Sleeve 35 Mm , Glass Sleeve 50 Mm , Glass Sleeve 70 Mm , Bridge Rectifier25amp. Routtanshaw Make , Fuse Link Ee Make 32 Amp. , Fuse Link Ee Make 63 Amp. , Potentio Meter 2K- 50Hm Rw-3K , M.C.B. Havells/L&T Make Single Pole 3 Amp , Do But 6 Amp , Do But 10 Amp , A.B. Contactor Lcid/73 16 Amp With Auxiliary Block , Push Buton Element Teknik Make , Potentio Meter2k5 3W Pankaj Make , T.C.Contactor 2No+2Nc With Aux. Block , T.C.Timer 0-30 Sec. Contactor Mount On /Off Delay , Indicating Lamp 7/10W With Lamp 220V (Pin/Screw Type) , Push Button Station With Box L&T Make , Hrc Fuse Link 32 Amp. Ee Make , Bkt Kit Kat Fuse Assly.. 63A Ee Make , Amp. Meter 0-5000Amp. Ctr 4300/5 1450X1450mmae , Kw Meter 0-3000Kw 1450X1450mm Ctr 4300/5Ae/L&T , Moving Arching Contact For 300A Ocb Mei Make , Dobut 400 Amp , Bch Make Timer 0-60 Sec.Single/Double Stage , Power Capacitor 3 Phase, 515 Volt, 25Kvar L&T Make With Test Certificate , Relay For Automatic Power Factor Controller 12 Stage , Carbon Bush Holder For Cane Unloader20 X 20 X 100 , Digital/Analog D.C. Ammeter 0-1500Amp.Ae/L&T Make Esd 1Ma 1.5 , Digital/Analog D.C. Ammeter (Alolog/Digital) 20-0-20 As 1248, Fsd 70-0-70 Mvm 96 Ae/L&T Make , Digital/Analog D.C. Voltameter 0-600V, M96, S1248, Fsd-1Ma Ae/L&T Make , Digital/Analog D.C. Voltameter M-96, S-1248, Fsd-1 Ma Ae/L&T Make , Slipring Suitable For 200 Hp Slipring Motor Bore 51Mm Ring Od 145Mm , Spare For Advance Make Ocb Type N2 Rating 300Amp.Spare Arching Contact , Do But Spare Moving Contact , Do But Spare Fixed Contact , Techo Generator Model Dtg 4000 Output 200 Vtc/4000 Rpm Maximum 400Mm Ador Make , Power Block Thyristor Type Tt75n/Mcc501-16102 Dixys , Thyrister Dcr-604 Se 1616 , Do But Dcr 604 , Do But Dcr, 1004 S/D 1616 , Do But St 2600/14 , Do Butdcr 806 / 807 , Carbon Bush(Asam Carbon Make) , Carbon Bush Size 25 X40 X 50Mm Eg-224 , Carbon Brush Size 20 X 40 X 50Mm Eg-224 , Do But 13 X 32 X 40Mm Eg-224 , Do But 12.5 X 32 X 40Mm Eg-224 , Do But 16 X 32 X 40Mm Eg-224 , Carbon Bush Size 20 X 20 X 100Mm Eg-224 , Carbon Bush Size 12 X 25 X 30Mm Eg-224 , Carbon Bush(Copper Mixed) For Slipring Motor 25 X 50 X 60Mm Bh-51 Asam Carbon Make , Do But 22 X 32 X 40Mm Bh-51 , Do But 5 X 19 X 25Mm Bh-51 , Do But 16 X 32 X 40Mm Cb-6 , Do But 20 X 40 X 50Mm Cb-6 , Graphite Carbon Bush (In Two Pcs) Size 45 X 40 X 20Mm Asam Carbon Make , Carbon Brush Holder For Above , Wolfmake Drill Machine , Slipring Holder For 200 Hp Motor , Slipring 5 Hp Kec Motor Id 500Mm , Change Over Switch 630A, 4 Pole S.S. Havells/Hpl With Test Certificate , Motor Connection Plate 120/90Hp Slipring Motor (Kec) , Motor Connection Plate 55Hp Slipring Motor (Jyoti) , Motor Connection Plate 33Hp Slipring Motor (Kec) , Motor Connection Plate 55Hp Slipring Motor (Ngef) , Slipring Holder 110 Kw Ngef Make Motor , Slipring Holder 200Hp Aei Make Motor , Dowells Paste , R.P.M. Meter Suitable For Thyrister Convertor Pannel (D.C.Pannel) Fsd Ima M-96 Meco Size 1200-0-1200Rpm , Digital/Analog A.C. Ammeter Of 0-800A Ctr-800/5 L&T Make , Digital/Analog A.C. Ammeter Of 300A Ctr-300/5 L&T Make , Digital/Analog A.C. Ammeter Of 200A Ctr-200/5 L&T Make , Digital/Analog C.T.S. For Ratio 0-800A Ctr-800/5 L&T Make , C.T.S. For Ratio 200A Ctr-200/5 , C.T.S. For Ratio 100A Ctr-100/5 , C.T.S. For Ratio 60A Ctr-60/5 , C.T.S. For Ratio 300A Ctr-300/5 , C.T.S. For Ratio 400A Ctr-400/5 , Volt Meter Ae Make For 0-500V Ac Size 140X140mm L&T Make , Volt Meter Ae Make For 0-500V Ac Size 95X95mm L&Tmake , Amp. Meter 1000Amp Ctr 1000/5 Size 95 X 95 L&T Make , Amp. Meter 400Amp Ctr 500/5 Digital/Analogl&T Make , Amp. Meter 250Amp Ctr 250/5 Digital/Analogl&T Make , Amp. Meter 300Amp Ctr 300/5 Digital/Analogl&T Make , Pneumatic Timer Bch Make In Single Stage For 0-60Sec , Pneumatic Timer Bch Make In Double Stage For 0-60Sec , Potentio Meter Ec Make 5Ka Type 5710 , M.C.B. Havells Make16 Amp , M.C.B. Havells Make20 Amp , Bkt Kit Kat 63 Amp L&T Make , Bkt Kit Kat 32 Amp L&T Make , Bkt Kit Kat 16 Amp L&T Make , S.S.Tension Spring For 500 Hp Motor C.B.Holder , 3 Phase Cooling Fan For 100 Kw Thyrister , M.S.Star Coupling As Per Sample , Carbon Brush Holder For Techo Generator As Per Sample , Bkt Fuse Carrior 125 A L&T Make , Power Thyristor 7 T 75 N , D.C.I.A.Mk-Iii Kec Make , New Work Cardkec Make , Bearing For Techo Generator Big Size , Bearing For Techo Generator Small Size , Indicating Lamp 220 V Dc Bch Make , Heating Element Rod 2000 W 2”/1” , Pressure Switch 4.5 Kgs Indofos Make Ips 70 , Digital Clamp Meter (Tingue Tester)1000A Motwani Make , Continuity Tester With Cell , Resistance 160 W 1-K As Per Sample , Capacitor 0.6 W 1200 Volt As Per Sample , Resistance 50 W As Per Sample , Soldering Strip (Lead Tin 60:40) , Soldering Wire 18 Swg , Soldering Flux Frysol Cooleson India Limited Make , Hydro Meter For Battery Leding , Copper Flexible Lead With Fibre Glass Insulated 10 Mm , Copper Flexible Lead With Fibre Glass Insulated 25 Mm , Copper Flexible Lead With Fibre Glass Insulated 35 Mm , Copper Flexible Lead With Fibre Glass Insulated 50 Mm , Mcb Tp 63 Amp Havells/ L&T Make , Mcb Tp 32 Amp Havells/ L&T Make , D.P.Switch 32 Amp Anchor/ Havells Make , Heating Rod 1000 Watt 2 Ft. Long , Heating Rod 1000 Watt 1 Ft Long , Backelite Sheet 20 Mm 4’ X 4’ , Carbon Brush For Grinder , Tpn Switch 63 Amp Havells/L&T Make , Axial Blower Fan For 700 Hp Thyrister Control Panel Thyrister Modular Make E.B.M. Module Azd-250, Aa-08-19254/440 Volt 60 Hz 2900 Rpm Made In West Germany , Mager For 500 Volt Mannual Operating , Heating Rod Of 2000 Watt 3 Feet Long U Shape , Handle For Acb 3200 Amp Type Draw Out Cncs , Carbon Brush Holder For 7.5 Hp Motor , Nomex Paper F- Class 7 Mile , White Paper7 Mile , Contactor T.C. 500 Amp , No Volt Coil 220 Volt Ac For Contactor 500 Amp T.C. , Add On Block For Above Contactor , Carbon Brush For Techo Generator , Fibre Fix Plate Suitable For Credle Assembly For Above L&T Make A.C.B. , Thyrister Mdt 2500/28 E (37Mm) Dcr 1476Sy2929 Imp Semikrim Thyrister , Semiconductor Fuse 1600 Amp, 1000V, Super Power 170 T 8173 4 Bk/90 90275 Busman Denmark , Brass Holder For 562 Kw Kec Make Dc Motor , Brass Holder For 700 Kw Kec Make Dc Motor , Carbon Brush Round , Carbon Brush Squire , Carbon Press Steel Spring , Digital Meger 1000V, 1000Mr Motwani/Rishabh Make , S.T.Bulb 300 Watt , S.T.Bulb 500 Watt , Auto Manual Selector Switch 2 Pole 2 Way L&T Make , Current Transformer 400/5A, 15 Va Clean-1 , Terminal Plate (Assembly) For Acb , Digital Energy Meter 415 Volt , C.T. 200/5 A.E./ L&T Make , Connection Plate For 4 Speed Meter , Mcb Box For 63 Amp Mcb , Spare Coil 240 Watt For Timer 0-60 Sec, 240 V Double Stage , Element For Timer Double Stage , Exhaust Fanblade Size 18 , Exhaust Fanblade Size 24 , Power Card (Pin-4) , Power Board For Analog Panel Srp-600 (700 Hp) , Under Voltage Release (Uvr) 220 Volt , Open Coil 220 Volt , Closing Coil 220 Volt , Plate (Complete Coil Set) , Ethernet Cable 03 Mtr , Cdp Connector , Control Card Kirloskar Make , Thyrister (Mcc501-16102) Dixys Make , Dc Volt Meter 0-600V Meco Make , Ampear Meter 0-500A Meco Make , Potentio Meter 2.5 Kvr , Thyrister Dcr-807 , Control Card (Con-4) , Power Card (Pin-4) , Power Card (Pin-51) , Dsl Card , Control Card For Vfd (2Nd Rake Cane Carrier) , Igbt With Thyrister For Above , Heavy Duty Limit Switch, General Purpose Cat Code Llgs Angular Liver , Pneumatic Timer, Coil-110V Ac, Type-Pcn, Range-05-60 Sec With Double Contact Block (1No+1Nc) Cat Code- Krtpcn11a-1
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 4
Uttar Pradesh View Result →
40.
Home Affairs #9421157 Technical Bid
Tender For Construction Of Sosmess (With 45 Rooms For Accommodating Single Living Assistant Sub-Inspectors) At 13Th Bn, Itbp Force, Lingdum, P.O.- Ranka, Gangtok, Sikkim-737101 - Civil, Electrical, E&M Items 2 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil 3 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 6 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 7 Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 8 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 9 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 10 Providing and laying in position cement concrete of specified grade1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). 12 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 14 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 15 Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level :Concrete of M10 grade with minimum cement content of 220 kg /cum 16 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum 17 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level.Concrete of M30 grade with minimum cement content of 350 kg /cum 18 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site Mof laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level.Concrete of M25 grade with minimum cement content of 330 kg /cum 19 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level.Concrete of M30 grade with minimum cement content of 350 kg /cum 20 Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). 21 Extra for rendering smooth the top of suspended floors, landings and staircases (treads and risers) with cement mortar 1:2 (1 cement : 2 coarse sand), including a floating coat of neat cement and protecting the surface with a layer of 7.5 cm of earth laid over 15 mm of fine sand in case of suspended floor and bricks laid in mud mortar in case of landings and steps, including subsequent removal and cleaning of the same. 22 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 23 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete 24 Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 25 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform 26 Centering and shuttering including strutting, propping etc. and removal of form for :Shelves (Cast in situ) 27 Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers 28 Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts 29 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 30 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 31 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) 32 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 33 Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 150mm/230mm/300 mm thick with Grade- I AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 34 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 35 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 36 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 37 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) 38 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) 39 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 40 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 42 With water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer 43 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification.Two or more coats on new work 44 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work 45 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 46 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work 47 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab upto 0.50 sqm 48 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm 49 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work 50 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 51 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. 52 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 53 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile 54 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile 55 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick 56 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 57 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. 58 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800 x 1600 mm 59 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood 60 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 61 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge.Extruded section profile size 42x50 mm 62 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places 63 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels)made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 64 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes 65 Providing & fixing ACP Sheet with EPDM rubber gasket in groove of meeting Style clips in Aluminium doors, windows, clerestory windows,Partition all complete with :5.0 mm thick ACP Sheet 66 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 67 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 68 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete :125x64x2.50 mm 69 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm 70 Providing and fixing bright finished brass night latch of approved quality including necessary screws etc. complete. 71 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125mm 72 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 73 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm 74 Providing and fixing ISI marked brass sliding door bolts with nuts and screws etc. complete 300x16 mm 75 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge 76 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :125x85x5.5 mm (heavy type) 77 Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete 150x125x27x5 mm 78 Providing and fixing of the MAC/VISTA/Hunter Douglas vertical Roller blinds with shade/screening and material complete with all acessories in all respect as per approved fabric/colour and texture 79 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :2nd class teak wood 50 x 20 mm 80 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 81 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 82 Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing C wall angle of size20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :GI Metal Ceiling Clip in plain Beveled edge global whitecolor tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 83 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 84 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works 85 Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 86 Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @ 0.70 kg per sqm 87 Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 88 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 89 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 90 Providing & fixing GRC panel (60mm thick) on external walls as per the architectural drawing. Fixing to be done on external wall including the necessary SS clamps, scaffoldings required etc. complete by specilised vendor in strict supervision of manufacturer as per direction of Engineer-in-Charge. 60 MM THICK 91 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick colour toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. 92 Providing and fixing 12 mm thick frameless toughened glass Door with all hardware of approved brand and manufacture,including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-char 93 Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishingcomplete. 94 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal sizederived from natural sources) 95 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 96 Providing and fixing 6 mm thick frameless toughened glass partation with all hardware of approved brand and manufacture,including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-char 97 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 98 Providing, fixing, testing and commissioning of star white colour vitreous china below / over counter Oval Wash Basin / circular basin (Size 560 x 410 mm or as/architectural detail drawing) with CP brass waste assembly complete including CI / MS brackets duly painted, cutting and making good the walls floors wherever required. 99 Providing, fixing, testing and commissioning of CP brass bottle trap with wall connection pipe for wash basins.32 mm dia 100 Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect 101 Providing and fixing C.P. brass towel ring with C.P. brass wall brackets & C.P brass screws complete in all respect 102 Providing and fixing 15mm C.P. copper connecting pipe 450mm long with C.P. brass nuts, washers complete In all 103 Providing and fixing C.P. soap dish of approved make including providing & fixing screws, washers, cutting & making good the walls. 104 Providing and fixing toilet paper holder.C.P. brass 105 Providing and fixing CP brass twin coat hooks fixed on toilet door/wall with CP brass screws, complete in all respect 106 Providing and fixing stainless steel kitchen sink as per I.S.13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required complete in all respect Kitchen sink with drain board 510 x 1040 bowl depth 200 mm 107 Providing, fixing, testing and commissioning of C.P. brass single hole sink mixer with CP wall flange, swinging spout complete as required and making good. 15 mm nominal dia. 108 Providing, fixing, testing and commissioning of white glazed vitreous china semi-stall lipped Urinal CI hangers CP spreader, 32/40 mm CP brass domical waste and pipe to wall with CP flange, automatic flushing system with concealed type electic operated, waterproof compact model solenoid valve with built in strainer, flow control mechnaism, stainless steel outer case, pre flush and main flush function and low battery indication, for individual urinals to ensure flushing only when in use, comprising of all plumbing & any other item required to provide satisfactory functioning as approved by the Architects complete including cutting and making good the walls and floors where required. (The gap between fixture and wall to be filled up with approved type poly sulphide sealant) Set of One urinal with flushing system. Urinal of size 580x380x350 mm or as/final architectural drawings. 109 Providing, fixing, testing and commissioning of CP brass bottle trap with wall connection pipe for urinals. 40 mm dia 110 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade 111 Providing and Fixing, testing & commissioning of ABS Health Faucet (complete with hook and flexible tube min. Length 1.0 m) as required complete in all respect 112 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal bore 113 Providing and Fixing, testing & commissioning C.P.brass wash basin mixer 15 mm nominal bore 114 Providing and Fixing in position 15 mm C.P. brass bib cocks of best quality (as approved by theProject manager). Bib cock long body 115 Providing and fixing & commissioning of position storage type automatic electric water heater pressure/ non pressure type themostratically controlled single phase, vertical wall mounted of approved make (to the approval of Engineer - in - charge) with thermostats, inner container of stainless steel complete with 1 Mtr three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. 25 litre capacity water heater 116 Providing and fixing & commissioning of position storage type automatic electric water heater pressure/ non pressure type themostratically controlled single phase, vertical wall mounted of approved make (to the approval of Engineer - in - charge) with thermostats, inner container of stainless steel complete with 1 Mtr three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. 50 litre capacity water heater 117 Providing and Fixing, testing & commissioning of C.P. brass Twin way bib cock of approved quality conforming to IS standards 15 mm nominal bore 118 Providing and Fixing, testing & commissioning of C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore 119 Providing and Fixing, testing & commissioning of C.P. brass towel rail fixed to rawl plug with C.P. brass screws. (600 mm long) Towel Rail 120 Providing and Fixing, testing & commissioning wall mixer with head shower & shower arm. Divertor + Spout + Shower Head 121 Providing and fixing liquid dispenser including all fittings complete. 122 Providing, fixing and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends, clamps, tees, cowls, clean out plugs, offsets, Y-tees, tees, door fittings, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 110 OD 123 Providing, fixing and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends, clamps, tees, cowls, clean out plugs, offsets, Y-tees, tees, door fittings, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 160 OD 124 Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. 100 mm inlet and 100 mm outlet. 125 Providing & fixing PVC EXTENSION PIECE for 100 mm dia floor trap formed out of main pipe(Type A) with multiple side inlets, suitable for various dia pipes, side connections, including all fixtures and fittings as per site conditions and as per standard 126 Providing and fixing Heavy Class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT. Size 100 mm X 100 mm 127 Providing and fixing Heavy Class SS grating with of approved design including setting in floor with cement motor to match with floor finish as per architect requirement .(for Bacony or floor Drain 128 Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees, tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 40 mm od uPVC pipe 129 Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees, tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 50 mm od uPVC pipe 130 Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees, tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 63 mm od uPVC pipe 131 Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 160 mm diameter (I) Single socketed pipes 132 Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 110 mm diameter (I) Single socketed pipes 133 Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 63mm diameter (I) Single socketed pipes 134 Providing , fixing / installation, testing and commissioning of 110 mm dia straight / offset Push fit type syphon uPVC WC pan connector with neoprene rubber ring and necessary accessories etc., complete. 135 Providing and fixing clean out plug comprising of uPVC caulked to UPVC pipes complete as required. 110 mm dia 136 Providing and fixing clean out plug comprising of uPVC caulked to UPVC pipes complete as required. 160 mm dia 137 Providing and fixing UPVC floor drain for balcony including all fitting and accessories fixed in cement mortar complete in all respect. 63 mm OD x 50 mm OD 138 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement :2 coarse sand: 4 hard stone aggregate 20mm and down gauge). 139 Providing and making Khurras with average minimum thickness of 5 cm Cement Concrete 1:2:4(1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20 mm nominal size) over PVC sheet 1 m x 1 m (PVC 400 microns min. thickness), finished with 12 mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand, admixed with waterproofing compound) and a coat of neat cement, rounding the edges and making & finishing the outlet complete Khurras Size 300 x 300 mm, for 110 OD/160OD outlet with 5 mm thick circular /Square horizontal or vertical C.I. grating. 140 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm dia nominal bore 141 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm dia nominal bore 142 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm dia nominal bore 143 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm dia nominal bore 144 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm dia nominal bore 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia nominal bore 146 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 15 mm dia nominal bore 147 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 20 mm dia nominal bore 148 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 25 mm dia nominal bore 149 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 32 mm dia nominal bore 150 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 40 mm dia nominal bore 151 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 50 mm dia nominal bore 152 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 65 mm dia nominal bore 153 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 80 mm dia nominal bore 154 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 15 mm dia nominal bore 155 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 20 mm dia nominal bore 156 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 25 mm dia nominal bore 157 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 32 mm dia nominal bore 158 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 40 mm dia nominal bore 159 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 50 mm dia nominal bore 160 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 65 mm dia nominal bore 161 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 80 mm dia nominal bore 162 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 15 mm dia. 163 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 20 mm dia. 164 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 25 mm dia. 165 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 32 mm dia. 166 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 40 mm dia. 167 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 50mm dia. 168 Providing and fixing Solenoid valve with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box etc., complete. 25mm dia. 169 Providing and fixing Butter fly valve with nitrile seat and stainless steel stem with lever operation and cast iron body in powder coated finish, suitable for test pressure of 10Kg/sq.mm) with flanges, gaskets and necessary pad locking arrangement complete required. 65 mm dia. 170 Providing and fixing Butter fly valve with nitrile seat and stainless steel stem with lever operation and cast iron body in powder coated finish, suitable for test pressure of 10Kg/sq.mm) with flanges, gaskets and necessary pad locking arrangement complete required. 80 mm dia. 171 Providing and fixing air release valve 15 mm dia 172 Providing and fixing 3 layer HDPE sintex tank on Teerace floor as per specification 3KL 173 Providing and fixing 3 layer HDPE sintex tank on Teerace floor as per specification 5KL 174 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m Pipes, cables etc. exceeding 80mm dia. But not exceeding 300mm dia. 175 Extra over for item no. 1.1 excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre) Pipes, cables etc. exceeding 80mm dia. But not exceeding 300mm dia. 176 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes withcollars jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement : 2 fine sand) including testing of joints etc. complete 150 mm dia R.C.C pipe 177 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes withcollars jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement : 2 fine sand) including testing of joints etc. Complete 250 mm dia R.C.C pipe 178 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) up to haunches of S.W./RCC pipes including bed concrete as per standard design : 150 mm dia R.C.C pipe 179 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) up to haunches of S.W./RCC pipes including bed concrete as per standard design : 250 mm dia R.C.C pipe 180 Constructing brick masonry manhole cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab with 1:2:4 mix ( 1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making necessary channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90 x 80 cm and 45 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With F.P.S. bricks with class designation 75 181 Constructing brick masonry manhole cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab with 1:2:4 mix ( 1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making necessary channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With F.P.S. bricks with class designation 75 182 Extra depth for manholes Size 90 x 80 cm (With With F.P.S. bricks with class designation 75) 183 Size 120 x 90 cm (With With F.P.S. bricks with class designation 75) 184 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design: With F.P.S. bricks 185 Extra depth beyond 45 cm of brick masonry chamber For 455 x 610 mm size With F.P.S. Bricks 186 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 187 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 188 Material & labour for constructing R.C.C. Grease trap of size 2000mm x 1200mm x 2500mm deep with RCC walls with inlet & outlet including necessary excavation and foundation concrete 100mm thick in 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate of 20mm nominal size), inside plaster 12mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement, RCC base slab, roof slab & baffle walls including reinforcement, centering & shuttering including 12mm dia steel bar footrests etc. and SFRC manhole cover and frame of 600mm x 450mm internal dimension conforming to IS: 12592 (total weight of cover & frame shall not be less than 70 kg) 189 Supply, instattation, Engineering, Testing and Commissioning of sewerage treatment plant all items to include providing all materials and its assembly, Labour, Consumables etc. as per standards and specifications, approved shop drawings at site.Sewage Treatment Plant (STP) using Moving Bed Bio Reactor (MBBR) or DRDO based Bio-Digester of capacity 10 KLD in civil construction and releted works including Design, Engineering, and preparation of providing all equipment / Piping etc at site, erection testing and 190 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A 191 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A 192 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 193 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 194 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Plug Wiring) 195 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (For Single Phase DB. From Sub Panel to DB) 196 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Sub Panel to DB) 197 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Sub Panel to DB) 198 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Sub Panel to DB) 199 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 200 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 201 Supplying and fixing suitable size GI box with modular plateand cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 202 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 203 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 204 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 205 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm 206 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 32 mm 207 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet 208 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet 209 Supplying and drawing co-axial TV cable RG-6 …. in the existing surface/ recessed steel/ PVC conduit as required. 210 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 211 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 212 Supply and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way, Double door 213 Supply and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door 214 Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator).6 way (4 + 18), Double door 215 Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 8 way (4 + 24), Double door 216 12 way (4 + 36), Double door 217 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB where 3 phase outlets are required.) TPDB is normally used 4 way (4 + 12), Double door 218 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 219 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 220 Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 amps 221 Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 222 Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 223 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25/32 amps 224 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 225 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 226 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 227 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 228 Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 229 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 230 Supply and installation of Kitchen Chimney with baffle filter, Stainless Steel, i/c Ducts for exhaust upto outer wall, push button operations, LED lights inclusive, noise(<60db), Exhaust area length x width (500 cmx 500cm) Exhaust motor rpm 2000 , V 220 W, >3500 cfmetc of approved brand as per directed by Engineer-in-charge. 231 Supply of 20 watt LED Tube Light rod, 4 long suitable with 40000 burning hours for rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply with aluminium alloy base,, frosted polycarbonate diffusers with power factor >0.90, Total Harmonic Distortion (THD) < 20%, system current - 0.085A, system efficiency > 85% , with operating temp. -10° C to 45° C, Lumen output for LED tube should be > 2000 lumen and overall lumen/watt of luminaire should be greater than 80%, C.R.I. of LED>80% with correlated colour temperature (CCT) of 6500K , minimum burning hour life >40000 hours,LED viewing angle 120 Degree complete in all respect with the entire satisfaction of the Engineer-in-incharge. Supply of Industrial General Purpose 4 long tube fitting suitable to house 1x20w LED tube rod 4 long, Polycarbonate housing , rated voltage 240 V and Ingress protection IP-20 complete in all respect with the entire satisfaction of the Engineer-in-incharge. 232 Bulkhead Light. 233 Wall Bracket Light. 234 Supply of 20 watt LED FLAMEPROOF Tube Light rod, 4 long suitable with 40000 burning hours for rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply with aluminium alloy base,, frosted polycarbonate diffusers with power factor >0.90, Total Harmonic Distortion (THD) < 20%, system current - 0.085A, system efficiency > 85% , with operating temp. -10° C to 45° C, Lumen output for LED tube should be > 2000 lumen and overall lumen/watt of luminaire should be greater than 80%, C.R.I. of LED>80% with correlated colour temperature (CCT) of 6500K , minimum burning hour life >40000 hours,LED viewing angle 120 Degree complete in all respect with the entire satisfaction of the Engineer-in-incharge. Supply of Industrial General Purpose 4 long tube fitting suitable to house 1x20w LED tube rod 4 long, Polycarbonate housing , rated voltage 240 V and Ingress protection IP-20 complete in all respect with the entire satisfaction of the Engineer-in-incharge. 235 Bollared Light. 236 LED exit signage Light. 237 Supply of recess mounting 15 W LED down light with high efficient LED’s, CCT-5700k -500 K,CRI >80,System lumen 100lm/W, Lumens ≥ 1000, single piece pressure die cast powder coated housing with opal diffuser for glare free & uniform lighting, Driver shall be of constant current type, operating temperature from -10 to +45degree celcius, power factor>0.90, rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Complete in all respect with the entire satisfaction of Engineer-in-Charge. 238 Supply of 9 W mirror light with high efficient LED’s, CCT-6500 K,CRI >70, Lumens ≥800, with Ingress protection IP-20, Driver shall be of constant current type, operating temperature from -10 to +45 degree celcius, power factor>0.90, rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Complete in all respect with the entire satisfaction of Engineer-in-Charge. 239 Supply of recess mounting 10 W LED down light with high efficient LED’s, CCT-5700k -500 K,CRI >80,System lumen 100lm/W, Lumens ≥ 1000, single piece pressure die cast powder coated housing with opal diffuser for glare free & uniform lighting, Driver shall be of constant current type, operating temperature from -10 to +45degree celcius, power factor>0.90, rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Complete in all respect with the entire satisfaction of Engineer-in-Charge. 240 Lamp Post Light. Make- Philips 241 Pendant Light. Make- Philips 242 Supply of 1200mm ceiling fans complete with double ball bearing, motor, blades, canopies, capacitor etc. suitable for operation on 230 volts, 50 Hz., 1 phase, AC supply with 5 star rating complete as required. ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 243 Supplying of Plastic Body Ornamental Exhaust Fan heavy duty 230V A.C 50 cycles, 300 mm sweep, 1300 rpm, energy efficient, complete erected in position with all accessories. 244 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness 245 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness 246 MAIN LT PANEL-1 Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 25 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. (Note:The contractor may select the next higher fault rating of MCCB if it is not readily available ,without any extra cost ,as the figure indicated within the bracket are required maximum fault level of the panel.) A INCOMER FRPM EXISTING SUPPLY;- 1 No. 400A 4P MCCB (36 KA) with electronic releases (O/C, S/C, E/F) 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 3 nos. indicating LED lamps for On/Off/ Trip with protective SP MCBs. 1 Set of CTs of the ratio630/5A for APFC Relay, Burden 15 VA ,1 Set of CTs of the ratio630/5A for APFC Relay, Burden 15 VA, 1 Set of CTs of the ratio630/5A with class 0.5 Accuracy for Metering, burden 15 VA , 1 Set of CTs of the ratio630/5A with class 0.5 Accuracy for Metering, burden 15 VA, 1 Set of. 400/5A , 15 VA, 5P10 CTs for Protection, 300 amps TPN Aluminium Busbar. BUSBARS - All busbars and interconnections shall be of suitable size Al strips current density of Al shall not be more than 0.8 Amps/ sq.mm. OUTGOINGS- 12 Nos. 63A (36kA) 4P MCCB., 4 Nos. 40A (36kA) 4P MCCB. ,4 Nos.32A (36kA) TPN MCB, 2 Nos.32A (10kA) DP MCB, MAIN LT PANEL as described above. Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts. 247 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium3.5 C x 185 sq. mm 248 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. AluminiumSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 120 sq. mm 249 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 50 sq. mm 250 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 185 sq. mm 251 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 120 sq. mm 252 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 50sq. mm 253 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 16 sq. mm 254 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 10sq. mm 255 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 256 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 257 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 258 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 259 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 260 Providing and fixing of lightning conductor finial, made of 25 mm dia 1200 mm long, copper tube, having single prong at top , with 85 mm dia 3 mm thick copper base plate including holes with insulation etc. complete as required. 261 Providing and fixing Copper Lightning Tape in Horizontal/Vertical Run: Providing and fixing copper tape 20mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. 262 Providing and fixing Testing Joint for Copper Lightning Conductor: Providing and fixing testing joint made of 32 mm X 6 mm thick copper strip, 125 mm long with 4 nos. of tinned brass bolts, nuts, check nuts and spring washers etc. complete as required. 263 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 264 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 265 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 266 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 267 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 268 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 269 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 270 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 271 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 272 Supplying, installation, testing & commissioning of addressable phone control module complete as required. 273 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 274 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 275 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. 276 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. 277 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 278 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 279 Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required. 280 Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required. 281 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 282 Supply, installation, testing and commissioning of 25 mm Outer dia CPVC PIPE with end caps including making air sampling opening of appropriate dia on appropriate interval and all accessories as required,(rate for area protected in sqm). 283 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 284 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm 285 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
41.
Educational and Research Institute #9420871 Technical Bid
Tender For Nagpur Book Fair 2025. Inviting Of Bids Through Central Public Procurement Portal (Cpp Portal) For Temporary Construction Of Hangar Structure/Auditorium, Fabrication Of Stalls/Pagodas Using Octonorm System, Installation Of Electrical Fittings, Pa System, Etc. On Hire Basis; 1 Dais: Size 48’ x 30’ x 4’in height made of wooden platform with new brand laminated synthetic carpet (*) with needle punch of saffron colour/red colour; • 1 table 15’ x 3’ with table cloth and frill in front• 1 lightening lamp• 15 executive wooden cushioned arm chairs• 15 Standing AC Tower (each of 2.5 ton)• 10 ceiling fan • 08 Sharpy Light/Beam Light (location to be informed later on)• Decoration of stage, entry gate & dais with fresh/artificial flowers should only be made after consulting the Festival/Officer In-charge• The arrangement of stairs with ramp (both sides) • 50 Mineral Water Bottles (200 ML) for Dais on per day basis • 10 Name plates of the guests at the Dias as per the direction of the Festival/Officer In-Charge. • 50 Iron Barricades of 4ft. (Height) x 6 ft. (Width)• 2 Podiums with NBT Logo on iron framing/sun board on three sides as per design provided by NBT2 Green Room in the form of Pagoda • Size 5mtr.x5mtr. with three side covered with orange paneling • 12 Spot Lights (9 watt each)• 2 LED Halogen lights (100 watt each)• 2 full length mirror with proper standTruss structure from main gate to main stage and main hanger with decoration of multi-colour paper streamer/cloth on passage area with 3D images of both side printed & laminated book covers as per the design shown at Annexure-XI (Approx 1500 Sqmtr.) 2 Dais: Size 32’ x 20’ x 4’ in height made of wooden platform with new brand laminated synthetic carpet (*) with needle punch of saffron color/red colour or as per actual requirement at festival site. The arrangement of stairs with ramp (both sides). 05 executive wooden cushioned arm chairs with 2 central table. 3 Complete PA system and Stage set-up for organizing Cultural / Rock Band Programmes with Operator for inaugural function and other programsalong with provision of fusion and rock musical band playing for the 9 days during the Book Festival with two helper along with the provision of additional sound & lights as per Tech Rider of Artists (As per the terms & conditions given at Annexure-IX) 4 Box Truss - Length 50’, height 24’, depth and as per stage size (on all four sides) Truss and Scaffolding/Speaker Tower as required 5 Stage Lighting – LED Par Light / Warm White / Moving Head Sharpy Lights / LED Wash Light, Profile Light, Blinder etc. and Controller (Approx. 75 Lights or as perStage requirement 6 FOH Console – Digital Audio Mixer Console 64 channels (Yamaha / A&H / Avid S6L) with laptops and DI Boxes required connecting cables for equipment. 7 Speakers 300–1200 Watt RMS Top speakers/Line Array/Side Fills/subs, Bass (19) Monitor (06) (L-Acoustics, JBL, D&B or equivalent) with Amplifier and other connecting equipmentsCenter-fills (with subs, if required) – as per venue and stage width. 8 Mikes- (10 fixed with stand and 8 cordless microphones, 5 Lapel/ head mic, 2 Podium mic) (Make Sennheiser / Shure/ AKG or equivalent). 9 Bass Guitar and Lead Guitar 10 Drum Riser (size 8 ft.x8x ft.x 1ft. (L x W x H)) 11 LED Screen Wall of Size 40’x10’ or as per requirement with masking & Riser (With operator) P5 – Back support connectivity with multi cam setup, USB connectivity and laptop for insertion for AV’s and TV’s and cables with wires and two power points for relay of Live Program.LED screen should be of the same length as per the stage size in actual 12 General PA System with Two Operators (For Authors’ programmes) 13 Console – Digital Audio Mixer Console 32 channels (Yamaha / A&H / Avid S6L) with laptops and DI Boxes required connecting cables for equipment. 14 Speakers 100–500 Watt RMS Top speakers, Bass (6) Monitor (4) (L-Acoustics, JBL, D&B or equivalent) with Amplifier and other connecting equipmentsCenter-fills (with subs, if required) – as per venue and stage width. 15 Mikes- (2 fixed with stand and 4 cordless microphones, 3 Lapel/ head mic, 1 Podium mic) (Make Sennheiser / Shure/ AKG or equivalent). 16 Announcement General PA System (Digital) with 20 Loudspeakers with 25–30-watt LMP and 2 Standing Mike (JBL/Sony/Phillips) for Announcement purpose 17 Brand New Executive Sofa Sets (3-seater) with white covers along with 25 central tables 18 Chairs with white cover for seat and back (Sample to be shown to In-charge) 19 Wheel Chair with Attendant with proper uniform 20 Queue Manager 21 Standing Air Conditioner (Tower) – 2.5 ton 22 Wooden Platform (4” to 9” height) with Brand new laminated carpet (*) for floor area (same specification as given for carpet in structure at s.no. 1) (as per on site requirement) 23 Bamboo (8ft. / 10ft.) 24 Tin Wall(8 ft.) with White/ saffron color New Cloth as per onsite requirement 25 Fire Fighting Equipment (CO₂ Water and powder mix with refilling dates) with one trained personnel with proper uniform for operating Fire Fighting Equipment. 26 Brand New Dustbins (50 ltr.) Plastic with Lid (Annexure-XV) 27 Supervisor with Sweepers for cleaning of ground are required one day before start of the Book Festival and till the end of the Festival (8:00 a.m. to 8:00 p.m.) 28 Supervisor 29 Sweepers 30 Supervisor with Security personnel in proper security uniform and necessary equipments are required to be deployed at venue one day before start of the Book Festival and thereafter round the clock till the end of the Book Festival: 31 Supervisor [preferably Ex-serviceman (age below 50 years) or well experienced security person below the age of 45 years] - Rates may be given for one supervisor for 24 hours duty (for 10 days) 32 Guards (well experienced security person below the age of 40 years) - Rates may be given for one Guard for 24 hours duty (for 10 days) 33 Fresh painted Steel Almirah with lock and key (Big) 34 Fresh painted Steel Almirah with lock and key (Small) 35 Flex printing without framing & mounting 36 Printing of flex & Hoarding with mounting on iron frame in different locations (onsite/offsite)* 37 Vinyl digital print (3.3 ft. x 8 ft.) 38 Sun board (5mm) – As per on site requirement 39 Selfie Point on Sun board (5mm with digital vinyl print and mounting/framing) – Size: 4’x6’ and as per requirement 40 Pedestal Fan/Ceiling Fan 41 BacklitHoarding 42 Maroon/Orange vinly printed Octonorm panels/walls (1mtr.) with frame (8 ft. height) 43 LED Spot Light (9 watt) 44 Parco Lights 45 Octonorm Table 46 Black Cushioned Chair 47 Plug point for computer with 5-15 Amp socket 48 Truss Structure (without water proof) with decoration of multi-colour paper streamer/cloth on passage area with 3D images of both side printed & laminated book covers as per the design shown at Annexure-XI (As per the directions of the Officer In-Charge 49 Green Net- As per onsite requirement. 50 Provision of preparing Chai/ Coffee with fresh milk & sugar etc. along with trained tea maker including disposable medium size cup for the guests during the entire period of the Festival (approx. 300 cup per day basis) 51 Polythene (4mtr.) for covering books inside stalls 52 White MS Shelve of size 96”x8.5” with 2” depth duly powder coated 53 Dustbin – 10 litre with lid and handle 54 Wooden/ steel tables 2’x5’ with frill 55 Pagoda (5mtr.x5mtr.) covered with wooden platform with new laminated carpet, 2 electric points, 2 octonorm tables, 4 visitor chairs and 4 Halogen LED Light of 100 watt with Fascia Name 56 Mojo Iron Barricades (Height 4 ft. x Length 6ft.) – As per onsite requirement/as per directions of the Officer In-Charge 57 LED Wall Screen of Size 12’x10’ or as per requirement with masking & Ramp (With operator) P5 – Back support connectivity with multi cam setup, USB connectivity and laptop for insertion for AV’s and TV’s and cables with wires and two power points (at the location decided by the Officer-In-Charge) for relay of Live Program. 58 LED TV (52 inch) — (The bazel 10m with stand and back support connectivity with multi-cam setup, USB connectivity and laptop for insertion for AV’s & TV’s, Sound system & stage fold back speakers, Sound mixing console, cables with wires and 5 Power Points 59 Providing of Labour for routine miscellaneous work from 10:00 a.m. to 9:00 p.m. (Rate may be given on per day basis) 60 Branded Desktop Computer system with good configuration (core i5-4th processor/DDR3 16GB RAM/512GB SSD/GT 730 4th GB graphics/19 inch HD LED Monitor/keyboard/mouse/window10/wi-fi 61 3 in 1 laser printer with cartridge, Scanner & photocopier with A-4 Size Paper ream (HP/Canon) 62 Lease Line with Wi-fi internet connection having 500 mbps with proper distribution at 10 different locations 63 Halogen LED Lights of 200 Watt with adjustable beam and angle complete with sufficient lighting and necessary wiring 64 5-Watt LED Colored / decorative bulbs 65 Tungsten outdoor warm lighting for decoration on trees 66 Silent Generator set: The generator should be in operational condition one day before start of the Book Festival and till the conclusion of the Festival. 67 One 125 KVA Generator set (with fuel and operator) for full duration 68 One 62 KVA Generator set (with fuel and operator) for full duration 69 (a) Main line connection:The approved vendor has to get the temporary electric connection for the book festival at his own cost.The bidder shall arrange installation of the connection, tendering of security deposit etc. to the government authorities at his own cost. Only actual consumption charges will be reimbursed to the bidder by NBT on production of original bill. In case of any problem in getting electric connection, it shall be the sole responsibility of the bidder to provide adequate supply through hiring more generators at his own cost one day before start of the Book Festival and no extra payment shall be given to the bidder for hiring and providing such extra generator, if any. 70 (b) Total job of cabling from electric meter and generator set sources and providing a line for connection inside the stalls of participants, illumination of Main Gate, toilet and entire area of the Exhibition ground and also to any other area inside and outside of the Exhibition venue (if required) with proper and sufficient supply.Note : 1) Providing power connection of various connected rating from switch board in various stands and with suitable size of cooper/aluminum 3½ /4 core armored cable and earth wire controlled with suitable capacity switchgear such as ICTPN, ICSPN/MCB i/c end termination laying of cable in floor, trench, carpets and tapping with power supply from permanent DB of the Ground i/c connections interconnection and maintenance during the Festival period. (The cables and other wiring need to be put under the wooden ramps/rubber covering mat etc. under the carpet on ground floor.2) Only one time payment as quoted by the tenderer will be made even in case of any increase or decrease in number of stalls. 71 Street light iron pole (20’x2-½’’) each pole with 12 LED lights and each light of 100 watt. 72 Photography for 10 days (Photographs should be provided in the hard disk and Pen Drive after the Book Festival). 400 photographs of inauguration and other important programs are required in high Resolution in Coffee table Album form in consultation with Officer In-charge. • Rate for per Unit cost for 10 days (Press Conference + Book Festival) may be quoted in the Financial Bid/BOQ. • Specifications for 01 Unit: DSLR full frame HD 4k Camera (with one gimbal setup) with minimum 6 cameras with photographer with each camera for 10 days.• Photography + Cameras would be as per onsite requirement and as per the directions of the Officer In-Charge. 73 Videography for 10 days (All Programs should be provided in HD format and high Resolution. The same should be provided in hard disk & Pen Drive after the Book Festival) along with 20 Minute short documentary of the programs along with 30 sec & 90 sec reels for each session on daily basis. • Rate for per Unit cost for 10 days (Press Conference + Book Festival) may be quoted in the Financial Bid/BOQ. • Specifications for 01 Unit: 6 Full HD Video Cameras with gimbal setup with minimum 6 videographers with each camera for 10 days.• Videography + Cameras would be as per onsite requirement and as per the directions of the Officer In-Charge 74 Two Drone Camera with two operators (each) for videography of the event on day-to-day basis with on-site permission and security clearance (All coverages should be provided in HD format and high Resolution. The same should be provided in hard disk & Pen Drive after the Book Festival). • Rate for per Unit cost for 10 days (Press Conference + Book Festival) may be quoted in the Financial Bid/BOQ.• Specifications: HD format and high Resolution would be as per onsite requirement and as per the directions of the Officer In-Charge 75 Live streaming on social media channels with Social Media Team of 2 members (YouTube & Facebook) – To be operated from 2-3 different places as per the onsite scheduled program/as per the direction of the Officer In-charge of the fair, Hence provision of sufficient wiring is to be made 76 CCTV Cameras with live telecast on Screen (Total 08 LED 52”) with complete installation with a control room access having sufficient number of staffs to manage the operation.Note: Complete footage/recording for entire event must be provided after the event to NBT in Hard Drive & Pen Drive (Rates may be given for full duration) 77 Refreshment packets approx. for children/students (each packet should contain – one packet of Good Day Biscuit, one packet of Britannia Fruit Cake, one packet of Lays Chips & one packet of Fruity/Real Juice/Maaza/Slice). 78 Hiring of Taxi (Swift Dzire) minimum 120 km and 12 hours duty 79 Hiring of taxi (Innova) minimum 120 km and 12 hours duty 80 Android Kiosk/Screen of latest version 81 Indian Flag (Khadi cloth) with mounting on Pole with 100 watt LED halogen light to be focused from bottom to top 82 Photo Exhibition with the following specifications:• Pagoda (5m x 5m)- 03• Orange Octonorm Panel- 50 (or as per requirement)• Glass Door (for entry & exit)- 02• Wooden Platform with new laminated carpet- 80 sq. mtr. or as per actual • LED Lights (9 watt)- 50 (or as per requirement)• LED light (100 watt)- 10 83 VVIP Lounges each consisting of the following (specification as per images enclosed at annexure VII) or as per onsite requirement/as per directions of the Officer In-Charge:• Size- 5 mtr. x 15 mtr.• Pantry as per requirement• Glass Doors- 02 (for exit & entry)• Sofa three seater (1) with cloth• Sofa two seater (2) with cloth• Glass Central Table (2)• Dustbin (20 ltr.)• VIP Toilet Van (picture attached at Annexure-XVI)• Sufficient lighting & power-points (concealed lighting)• Tower Air Conditioner 2.5 ton (4)• VIP chairs (4) 2 sides wooden/MDF wall having vinyl pasting (Design will be providing NBT) 84 Thematic Installation / Sculpture with complete set-up:Each Sculpture is to be made and placedon carpeted platform (wooden platform & carpet) at ideal height as per the size and design approved in the presentation and will consist the following items:i) 4-5 Parco lightsii) Cloth for masking the platform from all sidesiii) 5-6 Queue Manager 85 # 3D Selfie Point:# 3D Selfie point with symbol and acrylic words for the festival to be shown in Presentation with following items: i) 4-5 Parco lightsii) Cloth for masking the platform from all sidesiii) 5-6 Queue Manager 86 Vanity Van for 10 days (i.e. one day before start of the festival and till last day) 87 Roll up standee (3’ x 6’) 88 MDF wall with vinyl pasting inside the hangar structure (creatives to be provided by NBT) 89 Lunch/dinner (Veg. Thaali containing Jeera Rice, Sabji, Dal, Chapati- 04, Raita/Curd, Paneer, Salad & Sweet etc.) 90 Hi-Tea – for 100 Guest (Cocktail Samosa, Paneer Pakoda, Veg Sandwitch, Pastry, Tea & Coffee) with catering services as per requirement, rates may be quoted for per hi-tea basis. 91 Food Court: Covered area of approx 1000 sqm with tin shades and cloth:Entire boundary wall should be covered with balli/bamboo, tin wall & multi colour cloth and should have the following items therein:1.Customized Gate (as per the design & specifications shown & approved during the digital presentation)- 01(i) 2.Stalls- 10 (each 3mtr.x3mtr.) customized with balli/bamboo or(ii)pagoda and each stall with the following specifications/items:i) Covered with Octonorm panels from insideii) Platform with Carpetiii) Chairs-02 iv) Wooden/Steel Table-02 v) Multi Power points-02vi) Fan-01vii) Dustbin (50 ltr)-01viii) LED (100 watt)-02ix) LED Metal Light(100 watt) - 02In addition, entire open area should be covered with green net as well as with new laminated carpet and should have wooden round tables-20, pedestal fan-20, visitor chairs- 80and 20-dustbins (each 50 ltrs) with sufficient lights (LED 100 watts – 25 & LED Metal light – 20) to cover the entire open area. Note: the entire food structure design/specifications should be shown in the 3D format during the Digital Presentation 92 Customized Children Corner (As per the design shown & approved during presentation) Area 300 sq. mtr. 93 Digital Screen Gate – Providing LED Wall P2 left to right 100 sq. ft. (approx.) & top to bottom 14 ft., LED legs 14 ft. (Size would be as per actual dimension at festival site) with Entrance cutout, high resolution 4K content LED wall without dataton playback server at Entry Gate of the Festival. 94 PVC White or Coloured Sky advertising Balloon, 0.33 MM, Size 15ft.x15ft. 95 Gadda (6’x3’) with neat & clean white cotton sheets and cushions.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Maharashtra View Result →
42.
Educational and Research Institute #9414790 Technical Bid
PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ); 1 Mobile / Chemical Toilet block 4’ x4’With necessary tap fittings and fixtures including washbasin with the provision of water tank on the top having the capacity of 100 Ltr. of water on daily basis, doors (with key and lock system) with provision of water flow.Electrical fitting with bulb for sufficient light in toilet area as well as way to toilets (each separate for Ladies and Gents).Provision of liquid hand wash along with the tissue paper / napkin on daily basis 2 Gate Size: (width 20’xheight 20’) as per design given by NBT Office.Material: Gate to be made of Bamboo/Iron Frame with the provision of covering it with the metal frame from all side lettering on flex/digital vinyl print. Provision of 12 LED Halogen lights of 150 watts (4 LED each in 3 block / column) should be done in each entry gate to have proper visions for the visitors during night. Decoration of Gates with fresh/artificial flowers should also be made after consulting the Fair/Officer In-charge. 3 Customized GateCustomized gate in line with the theme of the Book Fair with detailed specifications as shown and approved during Digital Presentation 4 Stage: Size 32’ x 20’ x 4’ in height made of wooden platform with new brand laminated synthetic carpet (*) with needle punch of blue/red color; • 1 table 20’ x 3’ with table cloth and frill in front OR 10 Center Glass table• 1 lightening lamp• 15 executive wooden cushioned arm chairs with 10 side table of 3ft x 2ft size having vinyl pasting • 10 Standing AC Tower (each of 2.5 ton)• 10 Ceiling Fan • 1 LED Screen Wall (20’x10’) OR as per stage requirement • Decoration of stage, entry gate & dais with fresh/artificial flowers should only be made after consulting the Fair/Officer In-charge• The arrangement of stairs with ramp with railings for support (both sides of stage) having vinyl pasting on 4 sides • 100 Mineral Water Bottles (200 ML) for guests on stage, on per day basis • 20 Name plates of the guests on stage as per the direction of the Fair/Officer In-Charge. • 50 Mojo Barricades of 4ft. (Height) x 6 ft. (Width) with wheels• 2 Podiums with NBT Logo on sun board on three sides as per design provided by NBT2 Green Room in the form of Pagoda • Size 5mtr.x5mtr. with three side covered with orange paneling, wooden platform with new brand laminated synthetic carpet. • 12 Spot Lights (9 watt each)• 4 LED Halogen lights (100 watt each)• 4 full length mirror with proper standDraping Pathway / Truss structure from main gate to main stage (as per onsite requirement) with decoration of multi-colour paper streamer / cloth on passage area with book covers as per design provided by NBT. 5 Stage: Size 20’ x 12’ x 2½ ’ in height made of wooden platform with new brand laminated synthetic carpet (*) with needle punch of blue/red colour or as per actual requirement at fair site. The arrangement of stairs with ramp (both sides). 05 executive wooden cushioned arm chairs with 2 central table. 6 Complete PA system and Stage set-up for organizing Cultural / Rock Band Programmes with Operator for inaugural function and other programs along with provision of fusion and rock musical band playing for the 9 days during the Book Fair with two helper along with the provision of additional sound & lights as per Tech Rider of Artists (As per the terms & conditions given at Annexure-VIII) 7 Box Truss – Length 60’, height 24’, depth and as per stage size (on all four sides) Truss and Scaffolding/Speaker Tower as required 8 Stage Lighting – LED Parco Light / Warm White / Moving Head Sharpy Lights / LED Wash Light, Profile Light, Blinder etc. and Controller (Approx. 50 Lights or as perStage requirement 9 FOH Console – Digital Audio Mixer Console 64 channels (Yamaha / A&H / Avid S6L) with laptops and DI Boxes required connecting cables for equipment. 10 Speakers 300–1200 Watt RMS Top speakers/Line Array/Side Fills/subs, Bass (12) Monitor (03) (L-Acoustics, JBL, D&B or equivalent) with Amplifier and other connecting equipments Center-fills (with subs, if required) – as per venue and stage width. 11 Mikes - (4 fixed with stand and 4 cordless microphones, 2 Lapel/ head mic, 2 Podium mic, 2 in-ear/talk back mic), 2 condenser mic (Make Sennheiser / Shure/ AKG or equivalent). 12 Bass Guitar and Lead Guitar 13 Drum Riser (size 8 ft.x8x ft.x 1ft. (L x W x H) with wheels 14 Conga Set, djembe (dholak mic) 15 LED Screen Wall of Size 12’x10’ or as per requirement with masking & Riser (With operator) P5 – Back support connectivity with multi cam setup, USB connectivity and laptop for insertion for AV’s and TV’s and cables with wires and two power points for relay of Live Program.LED screen should be of the same length as per the stage size in actual 16 PA System with Two Operators (For Authors’ programmes) 17 Console – FOH 16 channels (Yamaha / A&H / Avid S6L) with laptops and DI Boxes required connecting cables for equipment. 18 Speakers 100–500 Watt RMS Top speakers, Bass (4) Monitor (2) (L-Acoustics, JBL, D&B or equivalent) with Amplifier and other connecting equipments Center-fills (with subs, if required) – as per venue and stage width. 19 Mikes - (4 cordless microphones, 1 Podium mic) (Make Sennheiser / Shure/ AKG or equivalent). 20 Announcement General PA System (Digital) with 12 Loudspeakers with 25–30-watt LMP and 1 Standing Mike (JBL/Sony/Phillips) for Announcement purpose 21 Executive Sofa Sets (3-seater) with white cover and 1 central table 22 Executive Sofa Sets (2-seater) with white cover and 1 central table 23 Black Stainless Steel Armless cushioned Chairs with white covers for seat and back 24 Wheel Chair with Attendant with proper uniform 25 Queue Manager 26 Brand new laminated carpet (*) for floor area (same specification as given for carpet in structure at s.no. 1) 27 Standing Air Conditioner (Tower) – 2.5 ton 28 Door with proper lock and key 29 Industrial Cooler (as per the pic enclosed) with the provision of water facility on daily basis. 30 Wooden Platform (4” to 9” height) with new laminated carpet 31 Cloth wall as per onsite requirement 32 Fire Fighting Equipment (CO₂ Water and powder mix with refilling dates) with one trained personnel with proper uniform for operating Fire Fighting Equipment. 33 Brand New Dustbins (Big Size) Plastic with cover 34 Supervisor with Sweepers for cleaning of ground are required one day before start of the Book Fair and till the end of the Fair (10:00 a.m. to 8:00 p.m.) 35 Supervisor 36 Sweepers 37 Supervisor with Security personnel in proper security uniform and necessary equipments are required to be deployed at venue one day before start of the Book Fair and thereafter round the clock till the end of the Book Fair: 38 Supervisor [preferably Ex-serviceman (age below 50 years) or well experienced security person below the age of 45 years] - Rates may be given for one supervisor for 24 hours duty (for 10 days) 39 Guards (well experienced security person below the age of 40 years) - Rates may be given for one Guard for 24 hours duty (for 10 days) 40 Fresh painted Steel Almirah with lock and key (Big) 41 Fresh painted Steel Almirah with lock and key (Small) 42 Flex printing and mounting without frame 43 Branding with printing and mounting in iron frame/wooden frame on different locations onsite or offsite 44 Vinyl digital print (3.3 ft. x 8 ft.) 45 Sunboard (5mm) – As per requirement 46 Selfie Point on Sunboard (5mm with digital vinyl print and mounting/framing) having heavy base (picture enclosed) – Size: 4’x6’ and as per requirement 47 Pedestal Fan/Ceiling Fan 48 Backlit Hoarding 49 White Octonorm panels/walls (1mtr.) with frame (8 ft. height) 50 Orange Coloured octonorm panels/walls (1mtr.) with frame (8 ft. height) 51 LED Spot Light (9 watt) 52 Octonorm Table 53 Black Cushioned Chair 54 A multi-plug point (four points) for computer with 20 Amp socket with switch 55 Truss Structure (without water proof) with printed multi-coloured cloth covering ceiling/sides) as per the directions of the Officer In-Charge 56 Truss Structure (water proof) with printed multi-coloured cloth covering ceiling/sides) as per the directions of the Officer In-Charge 57 Dark Blue Curtain (Cotton fabric) with uniform colour with provision of fastening and covering the stalls of equivalent size (3mtrx3mtr = 9 sqm) 58 Green Net 59 Tea/Coffee Vending Machine with sugar/milk/tea/disposable medium size cup with trained Operator for preparing tea/coffee for the guests during the entire period of the Festival (300 cup per day basis) 60 Polythene (4mtr.) for covering books inside stalls 61 White MS Shelve of size 96”x8.5” with 2” depth duly powder coated 62 Dustbin – 5 litre with lid and handle 63 Wooden/steel tables 2’x5’ with frill 64 Pagoda (5mtr.x5mtr.) structure on wooden platform with covering of synthetic needle punch with new laminated carpet of good quality having covered with three side white/orange octonorm paneling (size: 3.3ft. x 8 ft.), each with prefab octonorm system of the white colour in each stall, 9 LED light (each of 9 watts), one octonorm table for counter of the same colour, four black cushioned chairs with arms, a multi-plug point (four points), one new Dustbin. 65 Mojo Iron Barricades (Height 4 ft. x Length 6ft.) with wheel – As per onsite requirement/as per directions of the Officer In-Charge 66 LED TV (52 inch) — (The bazel 10m with stand and back support connectivity with multi-cam setup, USB connectivity and laptop for insertion for AV’s & TV’s, Sound system & stage fold back speakers, Sound mixing console, cables with wires and 5 Power Points 67 Providing of Labour for routine miscellaneous work from 10:00 a.m. to 9:00 p.m. (Rate may be given on per day basis) 68 Branded Desktop Computer system with good configuration (core i5-4th processor/DDR3 16GB RAM/512GB SSD/GT 730 4th GB graphics/19 inch HD LED Monitor/keyboard/mouse/window10/wi-fi 69 3 in 1 laser printer with cartridge, Scanner & photocopier with A-4 Size Paper ream (HP/Canon) 70 Lease Line with Wi-fi internet connection having 500 mbps with proper distribution at 10 different locations 71 Installation of Electrical fitting 72 Halogen LED Lights of 200 Watt with adjustable beam and angle complete with sufficient lighting and necessary wiring 73 5-Watt LED Colored / decorative bulbs 74 Tungsten outdoor warm lighting for decoration on trees 75 Silent Generator set: The generator should be in operational condition one day before start of the Book Fair and till the conclusion of the Fair. 76 One 125 KVA Generator set (with fuel and operator) for full duration 77 One 62 KVA Generator set (with fuel and operator) for full duration 78 Main line connection for total job from electric and generator set sources and providing a line for connection inside the stalls of participants, illumination of Main Gate and toilet, area of the exhibition ground and any other area of the ground, if required with proper and sufficient supply. It shall be the duty of the Bidder to get the temporary electric connection for the Fair at his own cost one day before start of the Book Fair. The Bidder shall arrange installation of the connection, tendering of Security Deposit etc., to Government Authorities at his own cost. Only actual consumption charges will be reimbursed to the Bidder by NBT on production of original bill. In case of any problem for getting electric connection, it shall be the sole responsibility of the Bidder to provide adequate supply through hiring more generators at his own cost one day before start of the Book Fair and no extra payment shall be given to Bidder for hiring and providing such extra generator, if any.Note : 3. Providing power connection of various connected rating from switch board in various stands and with suitable size of cooper/aluminum 3½ /4 core armored cable and earth wire controlled with suitable capacity switchgear such as ICTPN, ICSPN/MCB i/c end termination laying of cable in floor, trench, carpets and tapping with power supply from permanent DB of the Ground i/c connections interconnection and maintenance during the Fair period. (The cables and other wiring need to be put under the wooden ramps/rubber covering mat etc. under the carpet on ground floor.4. Only one time payment as quoted by the Tenderer will be made in case of any increase or decrease in number of stalls. 79 Street light iron poles (20’x2-½’’) with 4 LED halogen light each of 200 watt on each pole 80 Photography for 10 days (Photographs should be provided in the hard disk and Pen Drive after the Book Fair). 200 photographs of inauguration and other important programs are required in high Resolution in Coffee table Album form in consultation with Officer In-charge. • Rate for per Unit cost for 10 days (Press Conference + Book Fair) may be quoted in the Financial Bid/BOQ. • Specifications for 01 Unit: DSLR full frame HD 4k Camera with minimum 3 cameras with photographer with each camera for 10 days.• Photography + Cameras would be as per onsite requirement and as per the directions of the Officer In-Charge. 81 Videography for 10 days (All Programs should be provided in HD format and high Resolution. The same should be provided in hard disk & Pen Drive after the Book Fair) along with 20 Minute short documentary of the programs. • Rate for per Unit cost for 10 days (Press Conference + Book Fair) may be quoted in the Financial Bid/BOQ. • Specifications for 01 Unit: 3 Full HD Video Cameras setup with minimum 3 videographers with each camera for 10 days.• Videography + Cameras would be as per onsite requirement and as per the directions of the Officer In-Charge 82 One Drone Camera (Minimum 2 days or as per requirement) with operator for videography of the event on day-to-day basis with on-site permission and security clearance (All coverages should be provided in HD format and high Resolution. The same should be provided in hard disk & Pen Drive after the Book Fair). • Rate for per Unit cost for 10 days (Press Conference + Book Fair) may be quoted in the Financial Bid/BOQ.• Specifications: HD format and high Resolution would be as per onsite requirement and as per the directions of the Officer In-Charge 83 Live streaming on social media channels with Social Media Team of 2 members (YouTube & Facebook) 84 CCTV Cameras with live telecast on Screen (LED 52”) with complete installation with a control room access Note: Complete footage/recording for entire event must be provided after the event to NBT in Hard Drive & Pen Drive (Rates may be given for full duration) 85 Refreshment packets 500 each per day for children/students (each packet contains – one packet of Good Day Biscuit, one packet of Britannia Fruit Cake, one packet of Lays Chips & one packet of Fruity/Real Juice/Maaza/Slice 86 Hiring of Taxi (Swift Dzire) minimum 80 km and 12 hours duty 87 Hiring of taxi (Innova) minimum 80 km and 12 hours duty 88 Tin Wall with White/Blue Cloth (size: height 10 ft.) 89 Android Kiosk/Screen of latest version 90 Indian Flag (Khadi cloth) with mounting on Pole (20 feet height) with 100 watt LED (4 nos.) halogen light to be focused from bottom to top 91 Hangar Side Glass Wall (size: 1.25 mtr. x 12 ft.) 92 Round Table (Top 4ft.x4ft.) with legs (height 30 inches) with frill 93 Swiss cottages each consisting of the following (specification as per images enclosed at annexure VIII) – As per onsite requirement/as per directions of the Officer In-Charge:• Size – 64 sq. mtr.• 3 Sofa three seater with white cover/cloth• 2 Sofa two seater with white cover/cloth• 5 Glass Central Table • 5 Dustbins, each of 20 Litre• Attached washroom 6 x 16 (western washroom fittings)• 10 multi-plug points (with four points) for computer with 20 Amp socket with switch• 20 LED light • 4 Tower Air Conditioner 2.5 ton (each cottage)• 10 VIP chairs• 2 Big Almirahs• Photo Frame – 2 ft. x 4 ft. (Image will be provided by NBT)• 5 Pedestal Fans• 5 Ceiling Fans 94 Thematic Installation / Sculpture with complete set-up:Each Sculpture is to be made and placedon carpeted platform (wooden platform & carpet) at ideal height as per the size and design approved in the presentation and will consist the following items:i) 4-5 Parco lightsii) Cloth for masking the platform from all sidesiii) 5-6 Queue Manager 95 # 3D Selfie Point:# 3D Selfie point with symbol and acrylic words for the fair to be shown in Presentation with following items: i) 4-5 Parco lightsii) Cloth for masking the platform from all sidesiii) 5-6 Queue Manager 96 Picked fencing 97 Lunch/Dinner (Veg. Thaali) during the Book Fair 98 PVC White or Coloured Sky advertising Balloon, 0.33 MM, Size 12ft.x12ft. 99 MDF Wall inside the Hangar Structure with vinyl pasting
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
43.
Educational and Research Institute #9401915 Technical Bid
Supply And Installation Of Electronic Consumables Supply And Installation Of Electronic Consumables For The Department Of Design Iit Guwahati , Electronic Consumables , Arduino Uno (Original Arduino Uno Rev3) , Arduino Nano R (Original Arduino Nano) , Arduino Nano Iot (Original Arduino Nano 33 Iot) , Arduino Nano Esp (Arduino Nano Esp32-S3 Without Headers) , Arduino Nano Ble (Original Arduino Nano 33 Ble Board (Without Header)) , Arduino Mini (Arduino Pro Mini 328 3.3V/8 Mhz) , Arduino Mega (Original Arduino Mega 2560 Atmega2560 Mcu Rev3) , Arduino Giga R Wifi (Original Arduino Giga R1 Wifi) , Raspberry Pi (Raspberry Pi 4 Model B With 8Gb Ram (Latest & Original)) , Raspberry Pi (Raspberry Pi 5 Model With 8Gb Ram) , Raspberry Pi Power Adapter (Raspberry Pi 4 Usb-C Official Power Supply) , Raspberry Pi Heatsink (Black Aluminum Heat Sink Case With Double Fans For Raspberry Pi 4 Model B) , Raspberry Pi Heatsink (Official Raspberry Pi 5 Active Cooler) , Raspberry Pi Keyboard (Official Raspberry Pi Keyboard Red & White) , Raspberry Pi Mouse (Official Raspberry Pi Mouse Red & White) , Raspberry Pi Display (2.8 Inch 480 X 640 Dpi Ips Capacitive Touch Screen Lcd For Raspberry Pi) , Raspberry Pi Display (3.5Inch Resistive Touch Display (C) For Raspberry Pi, 480X320, 125Mhz High- Speed Sp) , Raspberry Pi Display (7? Official Raspberry Pi Display With Capacitive Touchscreen) , Raspberry Pi Display Case (Pi 4 Model B Touchscreen 7 Inch Display Case) , Nvedia Jatson Nano (Nvidia Jetson Nano 4Gb Developer Kit) , Jetson Nano Cooler (52Pi Low-Profile Ice Tower Fan For Jetson Nano) , Tft Diasplay Inch (2.4 Inch Spi Interface 240×320 Touch Screen Tft Colour Display Module) , Lcd Display Inch (1.69Inch Lcd Display Module, 240×280 Resolution, Spi Interface, Ips, 262K Colors) , Lcd Display Inch (2.4 Inch St7789 Tn Lcd Touch Display Panel) , Lcd Display Round (Rp2040 Mcu Board, With 1.28Inch Round Lcd) , Seven Segment Led Display Digit (4 Digits 7 Segment Led Display Module With Clock For Arduino) , Seven Segment Display (0.56 Inch Red 1 Digit 7 Segment Led Display 10Pin) , Usb To Ttl (Ch340g Usb To Ttl(Serial) Converter For Arduino Nano Raspberry Pi) , Bread Board (840 Points Solderless Breadboard) , Vero Board (General Purpose Pcb - 6X4 Inches) , Fan (24V Dc Blower Cooling Fan) , Fan (12V 5010 Cooling Fan For 3D Printer) , Fan (5V 4010 Blue Led Cooling Fan 40 X 40 X10mm) , Water Pump (55W Submersible Water Pump, Pure Copper Winding) , Water Pump (5 W Submersible Aquarium Water Pump) , Water Pump (12V 3M 240L/H Brushless Submersible Water Pump) , Water Pump (3-6V Dcsubmersible Mini Water Pump) , Water Pump (6-12V Dc Diaphragm Based Mini Aquarium Water Pump) , Water Pump (Dc5v Brushless Submersible Water Pump With Usb Power Input) , Air Pump (Kamoer 12V 12W 8000Ml/Min Hlvp8-Kk Diaphram Air Vaccum Pump) , Air Pump (12.0V Dc Mini Air Pump) , Air Pump (Silent And Adjustable Oxygen Pump) , Air Pump (Venus Aqua Aco-003 Air Pump) , Air Pump (Venus Aqua Aco-006 Aquarium Air Pump) , Transformer Step Down (0-24 24V 5A Step Down Transformer) , Transformer Step Down (0-12 12V 5A Step Down Transformer) , Transformer Step Down (0-6 6V 3A Step Down Transformer) , Transformer Step Down (12-0-12 Stepdown Transformer 1A) , Power Diode (By399 Fast / Ultrafast Power Diode) , Power Diode (10A 1000V Silicon Rectifier Diode) , Buck Converter (Buck Converter Power Transformer Supply Dc36v 24V 12V 9V To 5V 3A For Hub) , Fuse (250Ma 250V Glass Fuse - 5X20mm) , Fuse (250Ma 250V Glass Fuse - 6X30mm) , Variable Resistor (50 Ohm Variable Resistor - Trimpot) , Variable Resistor (500 Ohm Variable Resistor - Trimpot) , Variable Resistor (1K Ohm Variable Resistor - Trimpot) , Variable Resistor (10K Ohm Variable Resistor - Trimpot) , Variable Resistor (100K Ohm Variable Resistor - Trimpot) , Variable Resistor (200K Ohm Variable Resistor - Trimpot) , Variable Resistor (500K Ohm Variable Resistor - Trimpot) , Variable Resistor (1M Ohm Variable Resistor - Trimpot) , Lm (Fixed Linear Voltage Regulator, 7805, 10V To 35V In, 5V And 1.5A Out) , Ceramic Heater (12V 40W Ceramic Cartridge Heater) , Switch (1 Pin Flat Dial Switch 2.54Mm) , Switch (2 Way Slide Switch 2.54Mm Pitch - Pack Of 5) , Switch (5-Pin Flat Dial Switch 2.54Mm) , Switch (10 Pin Flat Dial Switch 2.54Mm) , Switch (12-Pin Flat Dial Switch 2.54Mm) , Switch (Dc5v-24V 12V 5A Pir Switch Infrared Motion Detector Sensor) , Switch (Dc 12V 1 Channel Relay Module Infrared Ir Remote Switch Control) , Switch (6X6x4.3Mm Tactile 4 Pin Push Button Switch - 5 Pieces Pack) , Switch (4X5 Matrix Array 20 Key Membrane Switch Keypad Keyboard For Arduino) , Switch (Slide Switch Sk-01) , Switch (Limit Switch-Wk1-2006) , Smps (12V 17A - 200W Ac/Dc Enclosed Switching Single Output Power Supply) , Solenoid Actuator (Dc12v 0.3N 10Mm Pull Type Solenoid Electromagnet) , Solenoid Actuator (Fa0520f 12V Dc 2-Position 3-Way Small Mini Electric Solenoid Valve For Air / Gas) , Laser High Power (High Power Laser 80W 450Nm For Engraving And Cutting) , Glass Cutting Disk (4-Inch(100Mm) Diamond Cutting Disc For Cutting Glass, Pack Of 4 Pcs, 12000 Rpm) , Teflon Tube (2Mm X 3Mm Ptfe Teflon Tube For 1.5 Mm 3D Printer Filaments) , Bearing (684 Zz Bearing 4X9x4 Shielded Miniature Ball Bearings) , Bearing (628Zz Bearing 8X24x8 Stainless Steel Shielded Miniature Bearings) , Bearing (6901Zz Bearing 12X24x6 Shielded Miniature Ball Bearings) , Bearing (12Mm Bore Inner Ball Mounted Pillow Block Insert Bearing) , Bearing (10Mm Bore Inner Ball Mounted Pillow Block Insert Bearing Kp000) , Bearing (10Mm Inner Diameter Zinc Alloy Pillow Block Flange Bearing Kfl000) , Bearing (8Mm Bore Inner Ball Mounted Pillow Block Insert Bearing Kp08) , Bearing (8Mm Inner Diameter Zinc Alloy Pillow Block Flange Bearing Kfl08) , Bearing (Sc16luu 16Mm Linear Ball Bearing Slide Unit For Cnc - 3D Printer) , Bearing (Sc10luu 10Mm Linear Ball Bearing Slide Unit For Cnc - 3D Printer) , Bearing (Sc8luu 8Mm Linear Ball Bearing Slide Unit For Cnc - 3D Printer) , Bearing (Linear Bearing Lmk12luu 12Mm Square Flange Bushing) , Bearing (Linear Bearing Lmk10luu 10Mm Square Flange Bushing) , Bearing (Linear Bearing Lmk8luu 8Mm Square Flange Bushing) , Lenses (75Mm Achromat Doublet Telescope Objective Lens With 900Mm Focal Length) , Lenses (75Mm Achromat Doublet Lens For Telescope,700Mm Focal Length) , Lenses (50Mm Aperture And 700Mm Focal Length (Make In India Product) F/14 Focal Ratio) , Lenses (Eyepiece For Telescope 10Mm 20Mm -Combo-Pack) , Lenses (Dwij 4Mm Eyepiece For Telescope,0.965) , Lenses (25Mm Non Coated Ramsden Eyepiece For Telescope,0.965) , Lenses (Omni 2X Barlow Lens - 1.25) , Reflector (Front Coated Optical Flat Mirror 25X36mm Diameter,5Mm Thick) , Audio Connector (3.5Mm Trss (Smd) Audio Jack) , Audio Connector (3.5Mm Audio Plug 3 Pole Gold-Plated Earphone Adapter) , Audio Module (Stereo Wireless Speaker Bluetooth 4.0 Audio Receiver Module) , Audio Module (Lm386 Audio Amplifier Module) , Audio Module (12V Stereo Noiseless Audio Power Amplifier Module With 2 X 15W Output) , Audio Module (Audio Dual Channel Stereo Digital Amplifier Board 80W*2) , Audio Speaker (4 Ohm Speaker - 0.5W) , Audio Speaker (8 Ohm Speaker - 0.5W) , Audio Speaker (Electronic Spice 2 Inch Tweeter Speaker Max Power 80W Upto 20Khz Pack Of 2) , Audio Speaker (4 Ohm 30 Watt Hifi Woofer Deep Bass) , Audio Cable (Speaker Cable Red And Black 65 Wire Od 3.6Mm X 7.2Mm - 50 Meter Coil) , Battery (3.7V 1200Mah 4.44Wh Icr-18650 Li-Ion Cell Rechargeable Battery) , Battery (3.7V 6800Mah Icr-21700 Li-Ion High Energy Rechargeable Battery) , Battery Holder (1 X 3.7V 18650 Lithium Polymer (Lipo) Battery Holder) , Battery Holder (2 X 3.7V 18650 Lithium Polymer (Lipo) Battery Holder) , Battery Holder (3 X 3.7V 18650 Lithium Polymer (Lipo) Battery Holder) , Battery Holder (4 X 3.7V 18650 Lithium Polymer (Lipo) Battery Holder) , Battery Charger (3S 10A 12V 18650 Lithium Battery Charger Board Protection Module) , Battery Charger (3 Series 20A 18650 Lithium Battery Protection Board 11.1V 12V 12.6V) , Battery Charger (Lithium Battery Shield V8 Mobile Power Expansion Board Module 5V/3A 3V/1A Micro) , Battery Charger (Micro Usb 2.0 5V 1A 18650 Tp4056 Lithium Li Ion Cell Battery Charger) , V Battery (Panasonic Alkaline 9V Battery) , Connector (5Mm Dc Jack Male-Female Pair Connector With Wire) , Connector (T Style Female Connector With Insulating Cap) , Connector (T Style Male Connector With Insulating Cap) , Connector (Xt60 Male Connectors - 2 Pieces Pack - Genuine) , Connector (Xt60 Female Connectors - 2 Pieces Pack - Genuine) , Connector (Red 55Mm Copper Insulated Crocodile Clip Opening 10Mm For Banana Plug 4Mm) , Connector (Blue 55Mm Copper Insulated Crocodile Clip Opening 10Mm For Banana Plug 4Mm) , Connector (Mt30 3 Pole Motor-Esc Connector Set Female) , Connector (Mt30 3 Pole Motor-Esc Connector Set Male) , Micro Drill Bit (0.1-1.0Mm Mixed 3D Printer Nozzle Cleaning Drill Bit Kit For Mk7 Mk8reprap - 10 Pie) , European Converter (Prime Deal 3 Pin Traveler Conversion Plug) , Extension Board (Board With 4 Universal Sockets, 3 Meter Long Cord, 1500 Watts, 6 Amp Multi Plug) , Led Strip (3528 Blue Smd Led Strip - 5 Meter) , Led Strip (5050 Green Smd Led Strip - 5 Meter) , Led Strip (5050 Red Smd Led Strip - 5 Meter) , Led Strip (5050 Yellow Smd Led Strip - 5 Meter) , Led Strip (3528 White Smd Led Strip - 5 Meter) , Led Strip (3528 Warm White Smd Led Strip - 5 Meter) , Led Strip Programmable (5V Addressable Rgb Non-Waterproof Led Strip - 5 Meter) , Led Strip Programmer (3Key Led Controller For Ws2811 Ws2812b Led Light Strip With Black Dc Jack) , Pv Panels (12V 10W Polycrystalline Solar Panel) , Pv Panels (12V 20W Polycrystalline Solar Panel) , Pv Panels (12V 40W Polycrystalline Solar Panel) , Pv Panels (12V 50W Polycrystalline Solar Panel) , Pv Panels (12V 100W Polycrystalline Solar Panel) , Solar Charger (12V Mppt Solar Charger Module) , Solar Controller (Xy-L10a 10A Lead-Acid Solar Storage Battery Charge Controller Module 6-60V) , Solar Controller (Xy-Cd60 Solar Battery Charger Controller Module Dc6-60V Charging Discharge Protec) , Solar Controller (60A Intelligent Lcd Solar Controller) , Glue Stick (Stanley 1-Gs20dt 100Mm/4X11.3Mm Dual Temperature Glue Stick) , D Print Pen (Goofoo Rp800a-White 3D Printing Pen) , D Pen Filament (3D Printing Pen Pcl Filaments) , Fingerprint Sensor (Grove Capacitive Fingerprint Scanner Module) , Ph Sensor (Industrial Grade Analog Ph Sensor / Meter Pro Kit V2) , Pir Sensor (Smart Digital Human Pir Motion Sensor Bs412 Iot Sensor) , Water Flow Sensor (Liquid Flow Sensor (G1/2)) , Water Gas Flow Sensor (Saier Sen-Hw06k Water Flow Sensor) , Pendrive (Sandisk Ultra Curve 64Gb Usb 3.2 Pen Drive 100Mb/S) , External Hdd (Portable 2Tb External Hdd Usb 3.0) , Brushless Motor (5010 360Kv High Torque Brushless Motor For Drone) , Brushless Motor (5010 750Kv High Torque Brushless Motor For Drone) , Brushless Motor (T-Motor Navigator Mn3110 700Kv) , Brushless Motor (Dys D2822 1450Kv Outrunner Brushless Drone Motor (Original)) , Brushless Motor (Dys D2826 2200Kv Outrunner Brushless Drone Motor (Original)) , Brushless Motor (Dys D2822 2600Kv Outrunner Brushless Drone Motor (Original)) , Dc Motor (615 Magnetic Micro Coreless Motor For Micro Quadcopters - 2Xcw And 2Xccw) , Ac Motor (Mini Sewing Machine Motor (Full Copper Winding) With Speed Controller) , Motor Controller (Brushless Motor Controller Dc 12-36V 500W Pwm Driver Board) , Motor Controller (Jhemcu Blheli_32- 55A 4In1 3-6S Esc) , Flight Controller (Fms Rc Airplane Gyro Reflex Flight Control System) , Flight Controller (Mini Osd With Plastic Shell For Apm 2.6/2.8) , Flight Controller (Sp Racing F3 Flight Controller Integrate Osd Acro Version) , Flight Controller (Apm 2.8 Flight Controller With Built-In Compass) , Flight Controller (Omnibus F4 V2 Pro Flight Controller With Sd Card Slot & Bec) , Flight Controller (Mamba F405 Flight Controller & Rev35 35A Blheli_S 2-6S 4 In 1 Esc) , Transmitter Receiver (Flysky Fs-I6s 2.4Ghz 10 Channel Afhds 2A Rc Transmitter With Fs-Ia10b 10 Channel) , Transmitter Receiver (Flysky Fs-T6 6 Channel Transmitter With Fs-R6b Receiver) , Transmitter Receiver (Frsky R9m 2019 Module And R9mx Receiver) , Transmitter Receiver (Cyclone Xf5804 Switchable Transmitter) , Drone Power Cable (Apm/Pixhawk Power Module V6.0 Output Bec 3A Xt60 Plug 28V 90A) , Propeller (6X4.5 Inch (6045) Hd Propellers Carbon Nylon Props 2Cw+2Ccw - 2 Pairs Black) , Propeller (Hqprop T63mmx8 Light Grey (2Cw+2Ccw)-Poly Carbonate Propeller) , Propeller (10X4.5 Inch - 1045/1045R Cw Ccw Propeller Pair For Quadcopter (Black)) , Propeller (Sunny Sky Eolo 114.5 Inch Propellers- A Pair (Straight Version)) , Propeller (Gemfan 1050-3 Glass Fiber Nylon Propeller) , Propeller (Hobbywing X8 3011 Propellers With Hub Ccw) , Propeller (Hobbywing X8 3011 Propellers With Hub Cw) , Gas Sensor (Mq2 Flammable Gas And Smoke Sensor Module) , Gas Sensor (Mq4 - Methane Natural Gas Sensor Module) , Gas Sensor (Mq6 - Lpg Propane Gas Sensor Module) , Gas Sensor (Mq8 Hydrogen H2 Gas Sensor Module) , Gas Sensor (Mq9 Carbon Monoxide, Methane And Lpg Gas Sensor Module) , Gas Sensor (Mq135 - Air Quality Gas Sensor Module) , E Bike Motor (6 Inch 250W 24V Brushless Hub Motor With Tyre For E-Bike) , E Bike Motor (350W 36V Hub Motor For Electric Bike Bicycle Front) , E Bike Controller (Brushless Controller 24V For Hub Motor 250W) , E Bike Controller (Ebike Brushless Sine Wave Motor Controller 36V For Hub Motor 350W) , E Bike Throttle (Digital Throttle With Key For Ebike) , E Bike Kit (Right Side Geared Ebike Kit My1016z3 24V 350W) , D Printer Nozzel (Complete Kit Of Mk8 Extruder With 0.3Mm Nozzle (Assembled)) , D Printer Nozzel (Complete Kit Of Mk8 Extruder With 0.5Mm Nozzle (Assembled)) , D Printer Nozzel (E3d V6 12V Direct Drive All-Metal Hotend Kit - 1.75Mm) , D Printer Nozzel (1.75Mm Bowden Extruder Full Kit) , D Printer Motherboard (Gt2560 Mainboard - Mega2560) , D Printer Motherboard (Ramps 1.4 3D Printer Controller Board Arduino Mega Shield) , D Printer Motherboard (Mks Gen V1.4 3D Printer Control Motherboard With 50Cm Usb Cable) , D Printer Leveling Sensor (3D Touch Auto Leveling Sensor) , D Printer Leveling Screw (M3 Headed Bed Adjusting Nut Type B For 3D Printers - 4 Pieces Pack) , D Printer Leveling Spring (Heat Bed Spacer Spring For 3D Printer Um2 Ultimaker2 - 4 Pieces Pack) , D Printer Hot Bed (Reprap Mk2b 3D Printers Dual Power Pcb Heat Bed With 14Awg Cable) , D Printer Hot Bed Controller (Mks Mosfet Heating Controller For 3D Printer Heat Bed/Extruder) , D Printer Hot Sticker (220 X 220 X 0.5Mm Frosted Heated Bed Sticker Build Plate Tape With Adhesive Backin) , D Printer Lead Screw (1000Mm Trapezoidal 4 Start Lead Screw 8Mm Thread 2Mm Pitch Lead Screw With Co) , D Printer Lead Screw (500Mm Trapezoidal 4 Start Lead Screw 8Mm Thread 2Mm Pitch Lead Screw With Cop) , D Printer Lead Nut (T8 Anti-Backlash Spring Loaded Nut For Cnc 8Mm Threaded Rod Lead Screw) , D Printer Smooth Rod (1000Mm Long Chrome Plated Smooth Rod Diameter 16Mm) , D Printer Smooth Rod (500Mm Long Chrome Plated Smooth Rod Diameter 16Mm) , D Printer Smooth Rod (1000Mm Long Chrome Plated Smooth Rod Diameter 10Mm) , D Printer Smooth Rod (500Mm Long Chrome Plated Smooth Rod Diameter 8Mm) , D Printer Timing Pully (Aluminum Gt2 Timing Pulley 20 Tooth 8Mm Bore For 6Mm Belt) , D Printer Timing Pully (Aluminum Gt2 Timing Double Head Pulley 20 Tooth 8Mm Bore For 6Mm Belt) , D Printer Timing Belt (10M Gt2 Width 6Mm Black Open Timing Belt For 3D Printer) , D Printer Timing Belt Spring (Tensioner Torsion Spring For Gt2 6Mm Timing Belt Used In 3D Printer - 5 Pieces Pack) , D Printer Linear Guide Rail (Mgn15h Linear Guide Rail - 1M With Sliding Block) , D Printer Linear Guide Rail (Mgn15h Linear Guide Rail - 0.5M With Sliding Block) , Cnc Controller (Cnc Three Axis Stepper Motor Drive Controller Motherboard Compatible With Arduin) , Smd Led (White Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Yellow Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Red Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Green Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Blue Led 1210 (3528) Smd Package - 10 Pieces Pack) , Smd Led (Green Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (Orange Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (Red Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (Blue Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (White Led - 0603 Smd Package - 10 Pieces Pack) , Smd Led (Yellow Led - 0603 Smd Package - 10 Pieces Pack) , Smd Resistor (47 Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (220 Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (330 Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (470 Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (1.2K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (10K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (33K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (100K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Resistor (330K Ohm 0603 Package 1/10W Smd Resistor 5% Tolerance (Reel Of 5000 Pieces)) , Smd Microcontroller (Atmega2560 - 16Au Microcontroller - (Smd Package) - Tqfp - 100 Pin Microcontroll) , Smd Microcontroller (Atmega328p - Au Microcontroller - (Smd Package) - Tqfp - 32 Pin Microcontroller) , Smd Rtc Ic (Ds3231 Ic - (Smd Sop-16 Package) - I2c Real Time Clock (Rtc) Ic) , Smd Voltage Regulator Ic (78M05 - 7805 - (Smd To-252/Dpak Package) - 5V Positive Voltage Regulator Ic) , Smd Voltage Regulator Ic (Ams1117-3.3V - Smd Sot-23 Package - Voltage Regulator Ic) , Smd Capacitor (100Uf 50V (Smd) Electrolytic Capacitor - 5 Pieces Pack) , Smd Capacitor (10Uf 50V (Smd) Electrolytic Capacitor - 5 Pieces Pack) , Smd Capacitor (47Uf 35V (Smd) Electrolytic Capacitor - 5 Pieces Pack) , Smd Ic (Ch340g (Smd Sop-16 Package) Usb To Serial Ttl Converter Ic) , Smd Ic (A4988 Ic - (Smd Package) - Stepper Motor Driver Ic) , Drill Bit (20Pcs 0.3-1.6Mm Shank Mini Micro Drill Bit Set Twist Drill) , Drill Bit (13 Pcs Hss Drill Bits 1.5Mm To 6.5Mm In Gradations Of 0.5Mm) , Gps Module (Seeedstudio Grove Gps (Air530)) , Humidifier Module (Dc 24V 36Mm Super Ultrasonic Mist Maker Humidifier Atomizer) , Heartrate Module (Max30100 Pulse Oximeter Heart Rate Sensor Module) , Hot Air Blower (Soldron 8858 Portable Hot Air Blower) , Gesture Sensor (Gy-9960- Llc 3-5V Apds-9960 Rgbgesture Sensor Motion Direction Recognition Mod) , Magnet (3Mm X 1.5Mm (3X1.5 Mm) Neodymium Disc Strong Magnet) , Magnet (5Mm X 3Mm (5X3 Mm) Neodymium Disc Strong Magnet) , Magnet (10Mm X 2.5Mm (10X2.5 Mm) Neodymium Disc Strong Magnet) , Magnet (10Mm X 5Mm X 2Mm (10X5x2 Mm) Neodymium Block Magnet) , Magnet (50Mm X 25Mm X 12.5Mm (50X25x12.5 Mm) Neodymium Block Magnet)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
44.
Power #9388772 Technical Bid
Procurement Of Consumable Items And General Spares For Miscellaneous Equipment Along With Safety Items (Ppe) For Dhalipur Power House , Consumable, General Spare And Ppe Items , Olddhoties Dully Washed 3 To 5 Meter Long, Old Cotton Dhotieswashed/Cleaned , Length Not Less Than 3 Meter, Width Not Less Than 1 Meter , White Cotton Cloth ( Jute ) Dry & Clean Thread Waste ( White ) Of Spinning / Weaving Mill In Good Condition. , White Markin For Cleaning Purpose, High Capability Property To Absorb Oil, Water And Other Liquid, 100 Percent Cotton, White Texture, Excellent Strength, , Jute Carpet Roll (Tat Patti) Having A Width-01 Meter , Modacrylic Coverall / Protex Coverall Flame Resistant, Colour –Blue,Or Grey Size-L To Xxl(3Nos.Of Each Size),Disposable Fabric: Flamex (55% Modacrylic, 43% Cotton 2% Antistatic)Make-3M , Wire Braded Flexible Hose Pipe Id-25 Mm,Pressure Range-0 To 10 Kg/Cm²,Colour- Black.Make-Mithra Italia Flex,Global,Polyhose , Aira Make Nrv 15 Mm ,High Pressure 0-100 Kg/Cm², Body-Ss ,Ends-Screwed (F) To Bsp , 1/2 Ball Valve ,Pressure Range-0 To 100 Kg/Cm²,3 Piece Ball Valve ,Body-Ss Make-Zoloto/Aira,F/B-R/B=F/B,End Type-Se,F To E=64 Mm , L&T Make Fn 63 Tpn/Fp Ce Switch With Enclosure Sk90484 Withinterior Fuse Unit, , L&T Make Hrc Fuse Cylindrical Type 63 Amp Cat-Sf90159 , L&T Make Mnx 32 Power Contactors 240V Ac (3 Pole),Model No-Cs94111dooo , L&T Make Mnx Contactor 95A 3P 415V Ac Ac-3 ,Aux Supply-415V Ac Coil, Freq-50/60 Hz,Model No-Cs94136dooo , L&T Make Mnx Contactor 70A 3P 415V Ac Ac-3 ,Aux Supply-415V Ac Coil,Freq-50/60 Hz,Model No-Cs97076dooo , L&T Make Mnx Contactor 50A 3P 415V Ac Ac-3, Aux Supply-415V Ac Coil,Freq-50/60 Hz,Model No-Cs97075dooo , L&T Make Mnx Contactor 12 A 3P 415V Ac Ac-3, Aux Supply-415V Ac Coil,Freq-50/60 Hz,Model No-Cs94109booo , Siemens Make Contactor Relay 4No 24V Dc,Model-3Rh214001bb40 , L&T Make 66-110 A Thermal Overload Relays For Mnx Contractor, Model No-Ss94137ooko , L&T Make Motor Protection Relay Mpr300,240V Ac,O/L Range (A): 32-88 A,Aux Supply-240 V Ac , L&T Make Mnx-A1 Add On Block.2No+2Nc 4 Poles Contactor, Sku:Cs94114oooo , Gic Make Sm 301,Single Phase Preventer Relay,Protects Against Phase Loss, Phase Reversal & Phase Asymmetry , Gic Make Sm 800 Supply Monitoring Series Relay,Model-Gicdma220,Phase And Voltage Control,Voltage-85-300 V Ac/Dc,Relay Out Put -2 C/O,Monitoring Of Under-Over Voltage & Frequency In 3 Phase Systems For Line/Phase Voltage.Monitoring Of Phase Loss, Phase Sequence, Phase Asymmetry & Neutral Fail. Measure True Rms Ac Voltage. Self & Auxiliary Power Devices.Configurable Power On Delay, Off Delay & On Delay. , Gic Make-Multifunction Electronic Timer Relay,Model-Gic-2Aadt5 Micron 225,24 - 240 V Ac/Dc,Mounting Type-Base / Din Rail , Switzer Make Pressure Switchmodel-711, Pressure Range-0 To 100 Bar ,Output Ac=100V-240V Ac,Output -18 V To 36 V Dc,Sensor Material-Ss 316,Process Connection-1/2? Npt (M) , Regulated Power Supply Unit, Incoming Voltage-100 Vac To 240 Vac, 140 Vdc To 340 Vdc ,Stable Output-Voltage (V Dc): 24.Output Current (Amp): 10,Output Power (Watt): 240,Line Regulation: 0.5% (Full Load).Load Regulation: 1% (230 Vac I/P).Make-Schneider,Abb , Ball Valve 25 Mm ,Body-Ss- 316,Pressure Range-0 To 100 Psi, End Connection Type-Threaded,Make-Skilt,Leader,Aira , 40Mm, 3 Piece Design Lever Operated Flanged End Ball Valve,Body Test Pressure-440 Psi,Thread Type-Bsp Female,Body-Ss, Length F To F=175 Mm, Make-Universal,Shreeram Engineers ,Zoloto,Aira , 40Amp Double Polercbo,Voltage-230V Ac,Sensitivity-30Ma,Make-Havells,Abb , 3 Phase 30 H.P Automatic Star-Delta Starter With Short Circuit Protection ,Relay Range:28-40 A , Model-Ihhdsdxc,Contactor Rating: 50 A,Full Load Line Current: 43.50 A,Full Load Phase Current: 25.12 A,Tp Mcb Rating (A): 100 A Make -Havells , Ac Control Relay, Model-Ca2kn31m7,3 No 1Nc,Coil Voltage-220 V Ac,Make-Schneider , Ac Control Relay, Model-Ca2kn31m7,3 No 1Nc,Coil Voltage-110 V Dc,Make-Schneider , Dc Control Relay, Model-Ca3kn22fd,2 No 2Nc,Coil Voltage-110 V Dc,Make-Schneider , 3 Poles Moulded Case Circuit Breaker 160 Amp,Breaking Capacity :70 Ka,Make-Schneider,Havells,Abb , Sensor Pt 100 Class A 3W,Output:-4 To 20 Ma(0 To 100 Deg C),Conn-G1/2 L=50 Mm,Model-Mma-00515C3da0 Make-Kobold , Sensor Pt 100 Class A 2W,Output:-4 To 20 Ma(0 To 100 Deg C),Conn-G1/2 L=470 Mm,Model-Mma-0Xxk15c2dao,Make-Kobold , Sensor Pt 100 Class A 3W,Output:-4 To 20 Ma(0 To 100 Deg C),Conn-G1/2 L=600 Mm,Model-Mma-060K15c2dao Make-Kobold , Industrial Safety Helmets With Ratchet Type Adjustable Strip,Colour-White,Make-Karam,3M , Industrial Safety Helmets With Ratchet Type Adjustable Strip,Colour-Blue,Make-Karam,3M , Industrial Safety Helmets With Racchet Type Adjustable Strip,Colour-Gray,Make-Karam,3M , Industrial Safety Shoes Antistatic Steel Toe Grey & Black Safety Shoes, Style :Low Cut, Sporty Toe Cap :Steel Toe Cap 200+-4 Joule Make-Allen Cooper/Karam/3M Protection :Impact Resistant Up To 200 J,Anti Static And Chemical Resistant , Rain Coat With Hood ,Waterproof, Set Of Top And Bottom ,Make-3M,Karam,Allen Cooper , Safety Goggles , Polycarbonate, Protects From Chemical Splashes, Clear Lens, Hardcoat, Transparent Goggles, Industrial Use Ansi Z87.1 Make-3M , Electrical Gloves 33 Kv Finger Type : Full Fingered Color : Yellowmake-Jyoti,Vidhyut , Electrical Gloves 11 Kv Finger Type : Full Fingered Color : Yellowmake-Jyoti,Vidhyut , First Aid Kit Box Mounting Type With Accessories I.E General Medicines,Cotton Gauze,Antiseptic Lotion,Povidine Lotion & Cotton For 20 Person Make-Thadani/Jilichem/St Johns , Kernmantle Rope 12 Mm(Length-30 Meter)Make-Karam/3M/Heapro/Allen Cooper , Polyamide Rope 20 Mm(Length-30 Meter)Make-Karam/3M/Heapro/Allen Cooper , Traffic Cone 750 Mm Base 300 X300 Mm With Chain And Hooks,Make-Frontier/Pioneer/Neelkamal/Supreme Or Equivalent , Led Search Light 20 Watt(Range 2 Km) With 10400Mah Lithium Battery,Multi-Functional Torch Make-Havells/Wipro/Bajaj/Hope/Andslite , Caution Tape Reflective Type With Sharp Colour Contrast,Yellow Tape With High Visible Bold Black Font,Made Of Quality Pe Material,Non-Adhesive Tape,Resistant To Fading,Tearing,Bad Weather And Waterproof,Thick And Durable,Size 75 Mmx200mx0.03 Mm Make-Darit/Ladwa/3M
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttarakhand View Result →
45.
Educational and Research Institute #9382746 Technical Bid
Tender For Sambalpur Book Fair 2025. Inviting Of Bids Through Central Public Procurement Portal (Cpp Portal) For Temporary Construction Of Hangar Structure/Auditorium, Fabrication Of Stalls/Pagodas Using Octonorm System, Installation Of Electrical Fittings, Pa System, Etc. On Hire Basis ; 1 Backdrop 2 Backdrop in the size of 32’ x 10’ with flex on metallic/wooden frame with lettering on flex of approved shade or as per actual requirement at fair site 3 Backdrop in the size of 32’ x 10’ with flex on metallic/wooden frame with lettering on flex of approved shade or as per actual requirement at fair site 4 Dais: Size 48’ x 30’ x 4’ in height made of wooden platform with new brand laminated synthetic carpet (*) with needle punch of blue/red color; • 1 table 15’ x 3’ with table cloth and frill in front• 1 lightening lamp• 10 executive wooden cushioned arm chairs• 4 Standing AC Tower (each of 2.5 ton)• 10 ceiling fan • 10 LED Parco Light/ Beam Light (multi-colored on truss structure) for cultural Events / programs• Decoration of stage, entry gate & dais with fresh/artificial flowers should only be made after consulting the Fair/Officer In-charge• The arrangement of stairs with ramp (both sides) • 50 Mineral Water Bottles (200 ML) for Dais on per day basis • 10 Name plates of the guests at the Dias as per the direction of the Fair/Officer In-Charge. • 10 Iron Barricades of 4ft. (Height) x 6 ft. (Width)• 2 Podiums with NBT Logo on iron framing/sun board on three sides as per design provided by NBTTruss structure from gate to Ground with decoration with multi-colour clothes on passage area with book covers as per design provided by NBT.2 Green Room in the form of Pagoda • Size 5mtr.x5mtr. with three side covered with orange paneling • 12 Spot Lights (9 watt each)• 2 LED Halogen lights (100 watt each)• 2 full length mirror with proper stand 5 Dais: Size 32’ x 20’ x 4’ in height made of wooden platform with new brand laminated synthetic carpet (*) with needle punch of blue/red colour or as per actual requirement at fair site. The arrangement of stairs with ramp (both sides). 05 executive wooden cushioned arm chairs with 2 central table. 6 Complete PA system and Stage set-up for organizing Cultural / Rock Band Programmes with Operator for inaugural function and other programs along with provision of fusion and rock musical band playing for the 9 days during the Book Fair with two helper along with the provision of additional sound & lights as per Tech Rider of Artists (As per the terms & conditions given at Annexure-X) 7 Box Truss - Length 50’, height 24’, depth and as per stage size (on all four sides) Truss and Scaffolding/Speaker Tower as required 8 Stage Lighting – LED Par Light / Warm White / Moving Head Sharpy Lights / LED Wash Light, Profile Light, Blinder etc. and Controller (Approx. 100 Lights or as perStage requirement 9 FOH Console – Digital Audio Mixer Console 64 channels (Yamaha / A&H / Avid S6L) with laptops and DI Boxes required connecting cables for equipment. 10 Speakers 300–1200 Watt RMS Top speakers/Line Array/Side Fills/subs, Bass (19) Monitor (06) (L-Acoustics, JBL, D&B or equivalent) with Amplifier and other connecting equipments Center-fills (with subs, if required) – as per venue and stage width. 11 Mikes - (10 fixed with stand and 8 cordless microphones, 5 Lapel/ head mic, 2 Podium mic) (Make Sennheiser / Shure/ AKG or equivalent). 12 Bass Guitar and Lead Guitar (1 Each) 13 Drum Riser (size 8 ft.x8x ft.x 1ft. (L x W x H)) 14 LED Screen Wall of Size 12’x10’ or as per requirement with masking & Riser (With operator) P5 – Back support connectivity with multi cam setup, USB connectivity and laptop for insertion for AV’s and TV’s and cables with wires and two power points for relay of Live Program.LED screen should be of the same length as per the stage size in actual 15 General PA Syatem with Two Operators (For Authors’ programmes) 16 Console – Digital Audio Mixer Console 32 channels (Yamaha / A&H / Avid S6L) with laptops and DI Boxes required connecting cables for equipment. 17 Speakers 100–500 Watt RMS Top speakers, Bass (6) Monitor (4) (L-Acoustics, JBL, D&B or equivalent) with Amplifier and other connecting equipments Center-fills (with subs, if required) – as per venue and stage width. 18 Mikes - (2 fixed with stand and 4 cordless microphones, 3 Lapel/ head mic, 1 Podium mic) (Make Sennheiser / Shure/ AKG or equivalent). 19 FOH console 16 channels (Yamaha/Avid S6L) with required connecting cables for equipment with 6 cordless mike (along with operator) 20 Complete General PA System (Digital) with 8 Loudspeakers with 25–30-watt LMP and 1 Standing Mike (JBL/Sony/Phillips) for Announcement purpose 21 Executive Sofa Sets (3-seater) with white covers along with 10 central tables 22 Chairs with white cover for seat and back 23 Wheel Chair with Attendant with proper uniform 24 Queue Manager 25 Brand new laminated carpet (*) for floor area (same specification as given for carpet in structure at s.no. 1) 26 Standing Air Conditioner (Tower) – 2.5 ton 27 Wooden Platform (4” to 9” height) with new laminated carpet 28 Bamboo (8ft. / 10ft.) 29 Iron Pole (8ft. / 10ft.) 30 Cloth (White/Blue) wall as per onsite requirement 31 Fire Fighting Equipment (CO₂ Water and powder mix with refilling dates) with one trained personnel with proper uniform for operating Fire Fighting Equipment. 32 Brand New Dustbins (Big Size) Plastic with cover 33 List of Exhibitors: size 12’x6’ (one each in Hindi/English/Odiya language)Schedule of programs: size 12’x6’ (one each in Hindi/English/Odiya language)Two Layout Designs of Fair site: size 12’x6’Including creative designing/printing with iron frame and mounting 34 Indicators/Signages 6’ x 3’ (Hindi/English/Odiya language)Including creative designing/printing with iron frame and mounting 35 Supervisor with Sweepers for cleaning of ground are required from the possession of the Book Fair venue and till the end of the Fair (10:00 a.m. to 8:00 p.m.) 36 Supervisor 37 Sweepers 38 Supervisor with Security personnel in proper security uniform and necessary equipments are required to be deployed at venue from possession of the Book Fair and thereafter round the clock till the end of the Book Fair: (*) Rates may be given on per day basis only: 39 Supervisor [preferably Ex-serviceman (age below 50 years) or well experienced security person below the age of 45 years] 40 Guards (well experienced security person below the age of 40 years) 41 Preparation of Hoardings 42 Vinyl digital print (3.3 ft. x 8 ft.) 43 Sunboard (5mm) – As per requirement 44 Selfie Point on Sunboard (5mm with digital vinyl print and mounting/framing) – Size: 4’x6’ and as per requirement 45 Fresh painted Steel Almirah with lock and key (Big) 46 Fresh painted Steel Almirah with lock and key (Small) 47 Pedestal Fan 48 Ceiling Fan 49 White Octonorm panels/walls (1mtr.) with frame (8 ft. height) 50 Orange Coloured octonorm panels/walls (1mtr.) with frame (8 ft. height) 51 LED Spot Light (9 watt) 52 Parco Lights 53 Octonorm Table 54 Black Cushioned Chair 55 Truss Structure (without water proof) with printed multi-coloured cloth covering ceiling/sides) as per the directions of the Officer In-Charge 56 Truss Structure (water proof) with printed multi-coloured cloth covering ceiling/sides) as per the directions of the Officer In-Charge 57 Dark Blue Curtain (Cotton fabric) with uniform colour with provision of fastening and covering the stalls of equivalent size 58 Printed Kanat for closing the Entry/Exit Gates of the Fair after the Book Fair Timings 59 Green Net 60 Green Grass Carpet 61 Tea and Coffee Vending Machine with sugar/milk/tea/disposable medium size cup with trained Operator during the entire period of the Festival (300 cup per day basis) 62 Draping Pathway 63 Polythene (4mtr.) for covering books inside stalls 64 White MS Shelve of size 96”x8.5” with 2” depth duly powder coated 65 Dustbin – 5 litre with lid and handle 66 Wooden/steel tables 2’x5’ with frill 67 Pagoda (5mtr.x5mtr.) with wooden platform, carpet, electric point and Halogen Light (100 watt) with adjustable beam and angle complete with sufficient lighting and necessary wiring and Fascia Name 68 Pagoda (3mtr.x3mtr.) with wooden platform, carpet, electric point and Halogen Light (100 watt) with adjustable beam and angle complete with sufficient lighting and necessary wiring and Fascia Name 69 Canopy: size: 5mtr.x5mtr. with 3 side cover, clear height: 7 feet, full height till Dome: 10 feet, colour-white, 2 electric points and 1 Halogen Light of 100 watt, 4 visitor chairs and 1 round table (Top 4ft.x4ft.) with legs (height 30 inches) and Fascia Name. The canopy contains 3 removable side walls, can install and disassemble as needed. 70 Canopy: size: 3mtr.x3mtr. with 3 side cover, clear height: 7 feet, full height till Dome: 10 feet, colour-white, 2 electric points and 1 Halogen Light of 100 watt, 4 visitor chairs and 1 round table (Top 4ft.x4ft.) with legs (height 30 inches) and Fascia Name. The canopy contains 3 removable side walls, can 71 Stall: Size 3m x 3m with panels, computerized vinyl pasting of name fascia, two LED light (100 watt), one plug point (15 Amp.) 72 LED Wall Screen of Size 8’x12’ or as per requirement with masking & Ramp (With operator) P5 – Back support connectivity with multi cam setup, USB connectivity and laptop for insertion for AV’s and TV’s, sound system and stage fold back speakers of 600 watts(2), sound mixing console and cables with wires and two power points (at the location decided by the Officer-In-Charge) for relay of Live Program. 73 LED Wall Screen of Size 12’x10’ or as per requirement with masking & Ramp (With operator) P5 – Back support connectivity with multi cam setup, USB connectivity and laptop for insertion for AV’s and TV’s, sound system and stage fold back speakers of 600 watts(2), sound mixing console and cables with wires and two power points (at the location decided by the Officer-In-Charge) for relay of Live Program. 74 LED TV (52 inch) — (The bazel 10m with stand and back support connectivity with multi-cam setup, USB connectivity and laptop for insertion for AV’s & TV’s, Sound system & stage fold back speakers, Sound mixing console, cables with wires and 5 Power Points 75 Providing of Labour for routine miscellaneous work from 10:00 a.m. to 9:00 p.m. (Rate may be given on per day basis) 76 Branded Desktop Computer system with good configuration (core i5-4th processor/DDR3 16GB RAM/512GB SSD/GT 730 4th GB graphics/19 inch HD LED Monitor/keyboard/mouse/window10/wi-fiwith computer table and sufficient power points 77 Lease Line with Wi-fi internet connection having 500 mbps with proper distribution at 10 different locations 78 3 in 1 laser printer with cartridge, Scanner & 02 photocopier Reams of A-4 Size (HP/Canon) with sufficient power points 79 FOH console 16 channels (Yamaha/Avid S6L) with required connecting cables for equipments. 80 LED Lights of 200 Watt with adjustable beam and angle complete with sufficient lighting and necessary wiring 81 5-Watt LED Colored / decorative bulbs/ warm light / white light 82 Tungsten outdoor warm lighting for decoration on trees 83 Silent Generator set: The generator should be in operational condition one day before start of the Book Fair and till the conclusion of the Fair. 84 One 125 KVA Generator set (with fuel and operator) for full duration 85 One 62 KVA Generator set (with fuel and operator) for full duration 86 Main line connection for total job from electric and generator set sources and providing a line for connection inside the stalls of participants, illumination of Main Gate and toilet, area of the exhibition ground and any other area of the ground, if required with proper and sufficient supply. It shall be the duty of the Bidder to get the temporary electric connection for the Fair at his own cost one day before start of the Book Fair. The Bidder shall arrange installation of the connection, tendering of Security Deposit etc., to Government Authorities at his own cost. Only actual consumption charges will be reimbursed to the Bidder by NBT on production of original bill. In case of any problem for getting electric connection, it shall be the sole responsibility of the Bidder to provide adequate supply through hiring more generators at his own cost one day before start of the Book Fair and no extra payment shall be given to Bidder for hiring and providing such extra generator, if any.Note : 1. Providing power connection of various connected rating from switch board in various stands and with suitable size of cooper/aluminum 3½ /4 core armored cable and earth wire controlled with suitable capacity switchgear such as ICTPN, ICSPN/MCB i/c end termination laying of cable in floor, trench, carpets and tapping with power supply from permanent DB of the Ground i/c connections interconnection and maintenance during the Fair period. (The cables and other wiring need to be put under the wooden ramps/rubber covering mat etc. under the carpet on ground floor.2. Only one time payment as quoted by the Tenderer will be made in case of any increase or decrease in number of stalls. 87 Street light iron poles (20’x2-½’’) 88 Photography for 10 days Photography (Photographs should be provided in the hard disk and Pen Drive after the Book Fair). 200 photographs of inauguration and other important programs are required in high Resolution in Coffee table Album form in consultation with Officer In-charge. • Rate for per Unit cost for 10 days (Press Conference + Book Fair) may be quoted in the Financial Bid/BOQ. • Specifications for 01 Unit: DSLR full frame HD 4k Camera with minimum 2 cameras with photographer with each camera for 10 days.• Photography + Cameras would be as per onsite requirement and as per the directions of the Officer In-Charge. 89 Videography for 10 days Videography (All Programs should be provided in HD format and high Resolution. The same should be provided in hard disk & Pen Drive after the Book Fair) along with 20 Minute short documentary of the programs. • Rate for per Unit cost for 10 days (Press Conference + Book Fair) may be quoted in the Financial Bid/BOQ. • Specifications for 01 Unit: 3 Full HD Video Cameras setup with minimum 3 videographers with each camera for 10 days.• Videography + Cameras would be as per onsite requirement and as per the directions of the Officer In-Charge 90 One Drone Camera with operator for videography of the event on day-to-day basis with on-site permission and security clearance (All coverages should be provided in HD format and high Resolution. The same should be provided in hard disk & Pen Drive after the Book Fair). • Rate for per Unit cost for 10 days (Press Conference + Book Fair) may be quoted in the Financial Bid/BOQ.• Specifications: HD format and high Resolution would be as per onsite requirement and as per the directions of the Officer In-Charge 91 Live streaming on social media channels with Social Media Team of 4 members (YouTube & Facebook) 92 CCTV Cameras with live telecast on Screen (LED 52”) with complete installation with a control room access Note: Complete footage/recording for entire event must be provided after the event to NBT in Hard Drive & Pen Drive (Rates may be given for full duration) 93 Paper Streamers decorating the path from main gate to auditorium / book fair along with hanging book covers 94 Refreshment packets 500 each per day for children/students (each packet contains – one packet of Good Day Biscuit, one packet of Britannia Fruit Cake, one packet of cookies/croissant & one packet of Fruity/Real Juice/Amul Milk 95 Hiring of Taxi (Swift Dzire) minimum 80 km and 12 hours duty (additional km. or hours will be paid on pro-rata basis) 96 Hiring of taxi (Innova) minimum 80 km and 12 hours duty (additional km. or hours will be paid on pro-rata basis) 97 Swiss cottage consisting the following (specification as per images enclosed at annexure VIII):• Size- 16 x 24• Sofa three seater (1) with cloth• Sofa two seater (2) with cloth• Glass Central Table (2)• Dust bin (1)• Attach washroom 6 x 16• Western washroom fitting• Sufficient lighting, power-point• Tower Air Conditioner 2.5 ton (2)• VIP chairs (4) 98 Indian Flag (Khadi cloth) with mounting on Pole with 100 watt LED halogen light to be focused from bottom to top 99 Round Table: Black Grey Night Marble/Wooden (Top 4ft.x4ft.) with steel legs (height 3-4 ft.) (as per sample attached at Annexure-IX) 100 Wooden/Steel Garden Bench (Three seater) 101 Medium Size Centre Glass Table 102 Touch Screen Digital Kiosk 103 Digital Standee (4’x8’) 104 Roll up Standee (Size: 6X3 feet)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
46.
Power #9336524 Technical Bid
RATE CONTRACT FOR UPKEEP / MAINTENANCE OF EXISTING 33/11 kV RECEIVING STATIONS ALONG WITH THEIR 33 kV LINES AND FABRICATION & HANDLING OF MATERIAL OF DIVISIONAL STORE UNDER THE JURISDICTION OF SUB-TRANSMISSION DIVISION-I, JPDCL, JAMMU FOR THE YEAR2025-26- 1 Erection of 16 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 2 Erection of 13 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 3 Erection of 11 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 4 Erection of 9 mtr long Steel Tubular Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 5 Erection of 13 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 6 Erection of 11 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 7 Erection of 9 mtr long PCC Pole with planting depth of 1/6 th of the height of the pole including digging of pits, disposal of extra earth, collection of boulders and filling back. 8 Painting of 16 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 9 Painting of 13 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 10 Painting of 11 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 11 Painting of 09 mtr long Steel Tubular Poleincluding fixtures with one coat of red-oxide and two coats of silver(aluminium) paint 12 Cement Bottoming (U/G,A/G) in 1:3:6 mix including excavation and form work, (16/13/11/9 Mtr Long Poles (Complete Job) 13 Fixing of Galvanisedspiral Earthing of SWG No. 8,G.I wire of 115 turns confirming to REC-J1 construction standard, (J1) 14 Fixing of 66/33KV Galvanised Guy Set (Guy wire, Guy Rods, Turn Buckle plate ,Guy Insulators) confirming to IS 2141 / 1979 or the latest version thereof including digging of pits & refilling 15 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (100mm2 ACSR Conductor) 16 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (150mm2 ACSR Conductor) 17 Collection of Snapped ACSR Cond. and Re-stringing, tensioning , binding of ACSR Conductor, (200mm2 ACSR Conductor) 18 Dismantling of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long ) up to distance of 50 mtr 19 Dismantling of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long ) up to distance of 50 mtr 20 Dismantling of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr 21 Dismantling of PCC Pole including carriage up to dumping site, (11 mtr. Long )up to distance of 50 mtr 22 Dismantling of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr 23 Dismantling of PCC Pole including carriage up to dumping site, (9 mtr. Long )up to distance of 50 mtr 24 Dismantling of Three/Four pole structure, opening of channels, crossarms, angles(Complete Job.) 25 Dismantling of Two pole structure, opening of channels, crossarms, angles (Complete Job.) 26 Straightening of tilted Steel Tubular Pole (16 mtr. Long ) 27 Straightening of tilted Steel Tubular Pole (13 mtr. Long ) 28 Straighteningof tilted Steel Tubular Pole(11 mtr. Long ) 29 Straighteningof tilted PCC Pole(11 mtr. Long ) 30 Straighteningof tilted Steel Tubular Pole(9 mtr. Long ) 31 Straighteningof tilted PCC Pole(9 mtr. Long ) 32 Unloading of Steel Tubular Pole including carriage up to dumping site, (16 mtr. Long )up to distance of 50 mtr 33 Unloading of Steel Tubular Pole including carriage up to dumping site, (13 mtr. Long )up to distance of 50 mtr 34 Unloading of Steel Tubular Pole including carriage up to dumping site, (11 mtr. Long ) 35 Unloading of Steel Tubular Pole including carriage up to dumping site, (9 mtr. Long ) up to distance of 50 mtr 36 Loading of Steel Tubular Poles including carriage up to dumping site, (16 mtr. Long ) 37 Loading of Steel Tubular Poles including carriage up to dumping site, (13 mtr. Long ) 38 Loading of Steel Tubular Poles including carriage up to dumping site, (11 mtr. Long ) 39 Loading of Steel Tubular Poles including carriage up to dumping site, (9 mtr. Long ) 40 Extra carriage from dumping site, (16 mtr. Long )up to site of work Its 100 mtr 41 Extra carriage from dumping site, (13 mtr. Long )up to site of work Ist 100 mtr 42 Extra carriage from dumping site, (11 mtr. Long )up to site of work Ist 100 mtr 43 Extra carriage from dumping site, (9 mtr. Long )up to site of work Ist 100 mtr 44 Extra carriage of 9 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in plain areas 45 Extra carriage of 11 Mtr PCC Polebeyond 100mtrs for every 50Mtr or part thereof in plain areas 46 Extra carriage of 9 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in semi hillyareas 47 Extra carriage of 11 Mtr PCC Pole beyond 100mtrs for every 50Mtr or part thereof in semi hilly areas 48 Unloading of Steel of Sorts , (Steel) 49 Loading of Steel of Sorts , (Steel) 50 Unloadingof Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor)at site 51 Loadingof Conductor Reels, (100mm²/150mm²/200mm² ACSR Conductor) at site 52 Fixing of 33 kVDiscInsulator (70 KN)2008 standards, (Porcelain ) 53 Fixing of 33 kV Disc fitting (70 KN) 2008 standards, (Polymer) 54 Fixing of 33 kV Insulators (10 KN) standards, (Porcelain ) 55 Fixing of33 kV Pin Insulators (10 KN) suitable for 100/150/200mm² ACSR Conductor. 56 Replacement/Fixing of 33 kVTension fittings (Socket & Ball type or T&C Type) for ACSR 57 Replacement/Fixing of 33 kV Tension fittings (Socket & Ball type or T&C Type) for ACSR 150m² 58 Replacement/Fixing of 33 kVTension fittings (Socket & Ball type or T&C Type) for ACSR 200m² 59 Straighteningof X-arms of different sizes (100x50x50x6 mm channel Iron,50x50x6mm Angle Iron ) duly painted with one coat of red-oxide and two coats of silver paint fixing with different sizes and sorts of nuts,bolts and washers, (Channel Iron X-arms, Angle Iron-X-arms, Pole Tops) 60 Straighteningof angle ironof different sizes (65x65x6 mm channel Iron,50x50x6mm Angle Iron 61 Repair and re-erection of Cradle for guard netting with GI wire 8 No including wire binding, cutting /bending of GI Wireas per REC standards 62 Branch cutting of 33 kV lines 63 Removing of wild climbers/vegetation around 33 kv Poles 64 Removing of wild climbers/vegetation around 33 kV Tower 65 Removing of wild climbers from top of 33 kV Lines. 66 Removing of wild climbers from Peak, cage, cross arm of 33 kV old tower Line 67 Patrolling of 33 kV Line(Routine/Under fault) 68 Tightening of loose guys 69 Dismantling & re-erection of damaged guys including digging of pit & refilling the same 70 Replacement of damaged Disc insulator in tension string 71 Replacement of cross arms of sizes 100x50x6 72 Replacement of angle iron of sizes (65x65x6, 50x50x6) 73 Replacement of Pin insulator on Four/Three/Double Pole Structure 74 Replacement of Pin insulator on Single Pole Structure 75 Replacement of Worn-out/Damaged Jumper of 33 kV Towerlines 76 Replacement of Disc Insulator, Suspension Fitting of 633 kV Towerlines 77 Replacement of worn-out/Loose/Damaged Jumper of 33 kV lines (sets of3 Nos) 78 Local earthing of 33 kV Lines by way of using discharge/earth rods at faulty site to avoid accident due to any induction while working on Line. 79 Tightening / restringing of loose ACSR Dog 100 mm2 80 Tightening / restringing of loose ACSR Wolf 150 mm2 81 Tightening / restringing of loose ACSR Panther200 mm2 82 Dismantling & Re-erection of ACSR Dog 100mm2 including collection of dismantled conductor , making of small bundles and its carriage 83 Dismantling & Re-erection of ACSR Wolf 150mm2 including collection of dismantled conductor , making of small bundles and its carriage 84 Dismantling & Re-erection of ACSR panther 200mm2 including collection of dismantled conductor , making of small bundles and its carriage 85 Dismantling of stay sets complete 86 33 KV VCB Repairs & Renovationby way of a) Setting of Mechanical Assembly / Replacement of damaged spring / Repair of locking & charging system 87 b) Replacement of Tripping Coil/Closing coil 88 c) Replacement of Damaged Vacuum Interrupter 89 d) Replacement ofBushing including Clamps 90 33 kV C&R Panel: Replacement of different equipmentsa) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch ,Selector SwitchIdentification of Panel Wiring Faults & its rectification 91 b) Replacement of Different Relays - MITNumerical Relay / Electro-mechanical relay / Master Trip Relay/ Differential Relay/Auxiliary Relay etc. 92 Installation, Testing, commissioning of 66-33 kV Control Relay Panels (Complete Job) 93 Complete testing of Relays Setting of Testing Kit, Interconnection between various points of panel with respect tosecondary injection key on various current taps, recording the observation thereof. All modifications necessary to achieve desired results. 94 Control Cable Replacement of damagedControl Cables of all typesincluding binding with PVC Belts/ Binding Wire, Peeling of insulation and fixing of proper size thimble connecting the cable after identification of each core to both ends i.e. Panel to CTs / panel toPTs /panel to Breaker and Making functional of 33 KV Outdoor Breakers, Protection , Alarms, Annunciation (complete Job) 95 Upkeep of earthing of aux. transformer 96 Upkeep of earthing of Power transformer 97 Upkeep of earthing of 33/11 kV LA 98 Providing of extra earthing for improvement purpose (complete job) 99 Upkeep of earth mat of out door yard 100 Replacement of damaged earth mesh in Sub-Station as per approved Map & Design. 101 Excavation of trenches of 0.6 Mtr Depth and 2.0 Mtr wide mtr in normal soil / hard soil 102 Repairing / Laying of MS Flat and MS Rod in deep excavated trench and welding of MS Flat & MS Rod with Mesh. 103 Repairing of Earthing with Spikes of MS Rod 20mm, 3 Mtr in Length as per REC Drawing 104 33/11 KV Power Transformera) Opening of Transformer Tank Top Cover to prevent oil leakage from top(if required to facilitate maintenance of transformer after removing the required accessories), ,Draining/ Re-Filling of required Oil, Change of gaskets of valves/ radiators/ Buchholzs relay radiators valves of power transformer of capacity: 3.15 MVA to 10 MVA 105 b) Replacement of silica gel 106 c) General Inspection by through inspection of each individual parts, Ratio test by applying voltage on HV Side and measuring LV Voltage on various Tap Positions, checking of Buchholz relay, Surge relay conservator, sensors, measurement of 1R-Value dialectic strength of oil, cleaning of Power Transformer etc 107 d) Replacement of any one of the following i.e. temperature indicators, gas operated Buchholzs relay, oil temperature indicator, winding temperature indicator etc 108 e) Preventing of leakage by changing main gaskets after removing the old gasket, Replacement of HV/LV Busing & Bush Rod,Ring and Rubber Washers (complete job to prevent leakages) 109 f) Cleaning of Scale deposited over the body and radiators of the power transformer with thinner/ detergent and de-rusting in perfect manner.(routine work) 110 g) Cleaning of LV/HV bushings of Power Transformer(routine work) 111 h) Replacement of Bus Bars ofPower Transformer 112 i) Replacement of LV/HV clamps of Power Transformer 113 Oil Topping of Power Transformer 10 MVA 114 Oil Topping of Power Transformer 4 MVA to 6.3 MVA 115 Oil Topping of Power Transformer 3.15 MVA 116 Recording of IR values of transformers 117 Installation, Testing and Commissing of Power Transformer 66-33/11 KV Installation of LV/HV Bus Bars with proper care, of transformer for any leakagecommissioning of Power of Transformers by applying low voltageapproximately equal to impedance voltage on HV Side and short circuiting the LV terminals, Energizing the transformer by applying required primary voltage to it & keeping the transformer on no load to observe the behaviour of transformer, setting on 25% of the load on the transformer for a period of at test 6 hours and observation of oil including temperature, increase the transformer is fully loaded and topping of oil.a) 10 MVA 118 b) 6.3 MVA 119 c) upto 5 MVA 120 Checking and tightening of Jumpers, Droppers in 66/33 KV Outdoor Yard 121 Replacement of T/PG clamps 122 Replacement of Disc insulators including its hardware. 123 33 KV LA & 11 KV Stn. Type LAReplacement of 66 KV,33 KV & 11 KV Lightening Arrestor including jumpering and earth connecting in all respect. a) 66 KV LA 124 b) 33 KV LA 125 b) 11 KV LA 126 Separate pipe Earthing / G.I Rod earthingas per REC Drawing J.2 127 Replacement of pipe earthing / Rod earthing with new one 128 Installation, testing and Commissioning, replacement of 66 KV Isolators 129 Installation, testing and Commissioning,replacement of 33 KV Isolators 130 Replacement of11 KV Isolators 131 Repair & Renovationof 66/33 KV and 11 KV isolators including setting right its alignment for proper operation, lubrication/greasing of jaws, bearings operatings handle etc(complete job) 132 Replacement of worn-out/heated Pad clamp/Isolator clamps of 66/33/11 kV Isolator by way of dismantling. Drilling of holes on new and fixing (complete job) 133 Repair & Renovationof Isolator Jaws 66/33 KV and 11 KV isolators.(complete job) 134 Replacement of post insulator / tendon pipes/ operating box by way of dimentalling, necessary fabrication where ever required for proper operation of 66/33/11 kv Isolators. 135 33 KV CTsInstallation, testing and Commissioning of 33 kV CTs ( of all ratios )Complete Job 136 33 KV CTsRepairs & Renovation of 33 KV CTs by way of replacing shorting strips, connecting rod, transformer oil, damaged insulator (CTs of all ratios) 137 Replacement of 33 KV Outdoor Type CT of different ratio and dismantling of damaged CT(CTs of all ratios) 138 Oil Topping of 66/33 kV CT & PT by way of opening of top cover and refixing with new gaskets if necessary and preventing of oil leakages if any.(complete job) 139 66-33 kV PTsInstallation, testing and Commissioning of 66-33 kV PTs (complete job) 140 66 kV PTsReplacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure. 141 33 kV PTsReplacement of 66 KV Outdoor Type PT and dismantling of damaged PT, dragging to installation/loading site, lifting from ground to steel structure 142 Cleaning of porcelain bushing, tightening ofPT/CT clamps, derusting & painting of body of 33 kV PTs & CTs 143 Tightening of nuts & bolts, replacement of oval thread bolts, chipping by way of welding to the bolts after tightening in a single bay 144 Painting with mix red oxide paint two coats of approved make on steel works after cleaning with wire brush/ sand paper 145 Painting of steel structure erected in outdoor yard with aluminium paint two coats with approved brand andfixture to given an even surface 146 Battery Banka) Repair & maintenance of battery set including maintaining specific gravity, electrolyte level, cleaning, checking, tightening of battery terminals in all respects it includes measuring voltage of each battery. 147 b) Tightening of all nut and bolts, replacement of damaged battery cells 148 c) Installation, testing and Commissioning of Battery Bank (complete Job) 149 Battery ChargerRepair/Renovation battery charger for proper functioning by way of replacement of rectifier unit, Ammeter, Voltmeter, MCB,Cooling fan, LED indications, buzzer alarms for OV/UV etc (Complete Job) 150 Repair and maintenance of DC Board, identification of fault in respect of cableand its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job. 151 Repair and maintenance of AC Board, identification of fault in respect of cableand its replacement, replacement of damaged MCCB, Kit Kat, Bus Bar & other allied job. 152 Installation, testing and Commissioning of Battery Charger (complete Job) 153 Deweeding of vegetation in outdoor yardRemoving of stone metal, deweeding of unwanted vegetation, spreading of stone metal collected earlier for removal of vegetation, levelling the area with existing stone metal 154 Providing of additional stone metal and its carriage and laying in outdoor yard, this including breaking of stones complete job. 155 Cleaning of Control Room, removing dirt & dust from the panels, walls, cleaning of fixtures (for one bank) 156 Painting of internal/external walls and roof by approved brand of oil based distemper 157 Painting of door and window panels of control room by approved brand of paint 158 Repairs & Renovation of 11 KV VCB,by way of replacement of a) Grid-spout assembly 159 b)Replacement of damaged CTs of different ratio Testing the CT with the help of primary injection set fixing in pannel, fixing the secondary connection after assessing the load (complete job) 160 c)Thorough checking of control wiring circuits, replacement of damaged wire if any, replacement of terminal plates, tripping circuits, close/ trip switch, ammeter switch, replacement of voltmeter & ammeter . 161 d) Replacement of 11 KV damaged PT 162 e) Replacement of blown fuses, checking the PT terminal with respect of 11 KV bus bar complete job. 163 f) Replacement of Trip/Close coil 164 g) Replacement of Trivector meter on 11/33/66 kV Panels 165 Installation, testing and Commissioning , replacement of LT cabele 166 11 KV Power Cables / 33 KV Power cables/66 KV Power cablesa) Identification of damaged portion of cable, tracing of cable, remove cable from trench, carriage and laying of cable(complete job) including cleaning of cable trenches. 167 b) Replacement of damaged cable of sizes 168 Replacementof termination kits of different sizes, connecting the cable with panel and outgoing structures after crimping of lugs fixing with nuts and bolts, checking of earth point, connecting the earthing point of cable with existing earthing system a) 11 KV Indoor Termination Kit (1-Phase/ 3 phase) 169 b) 11 KV Outdoor Termination Kit (1-Phase/ 3 phase) 170 c) 33 KV Indoor Termination Kit (Single Phase) 171 d) 33 KV Outdoor Termination Kit (Three Phase) 172 e) 33 KV Indoor Termination Kit (Three Phase) 173 f) 33 KV Outdoor Termination Kit (Single Phase) 174 Improvement of earthing system in control room by way of replacement of earthing risers from earthing point to panel / checking of all welding points/ re-welding of lose connection, laying of fresh / additional earth-mat strip to improve the existing earthing system (Complete one Panel set) 175 Checking of IR values 176 De-watering of receiving station to avoid water logging. 177 Repairing of electrical circuits for improvement of control room immunination, power points etc (Complete Job) 178 Installation, Testing, commissiing for replacement of Aux. Transformer at receiving station 179 On site repairing of aux transformer for missing phase, LT strip, LT bush rod, LT bush cup, HT bush rod etc (Complete job) 180 Transport charges for carriage of T&P, men & material on urgent basis during power breakdown and restoration of system. (auto carrier) aditional 1km @ 90/per km 181 Replacement of out door yard lights including wiring system and fixing oflamps on fixtures. 182 Marking of equipments, sign boards by way of painting/fixing of PVC plates for demarcation of different equipment to avoid mishandling. 183 Replacement/repair/fixing of ceiling fans at Receiving station. 184 Replacement/repair/fixing of cooling fans on radiators of power transformer to avoid heating. 185 Flash in 66KV,33 KV & 11 KV Panels due to overloading moisture, Cleaning of carbonized panel by petrol / cotton cloth, replacement of damaged / worn-out lugs, post insulator, Bakelite sheet, arcing chamber panel heaters etc. 186 Repair of plaster of thickness 12 mm to 20 mm in patches of areas 2.5 sqm meters and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete incl. disposal of rubbish to the dumping ground within 50 M leada) with Cement mortar 1:4 (1 cement : 4 fine / coarse sand) 187 Cutting of large tree branches falling over 33/11 lines and coming into the corridor to avoid damages/ faults/conductor snapping. 188 Cleaning of cable duct, removing of duct covers and placing back after cleaning the duct including disposal of rubbish up to 50 Mtr lead 189 Replacing sand store slabs in roofing, laid incement mortar 1:4 (1 cement : 4 coarse sand) including necessary repairs and cement painting with same mortar complete, including disposal of rubbish to dumping ground within 50 Meters of lead 190 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chow khats, holdfast etc. Complete and stacking with 50 Mtr lead 191 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel T-sections, joints mitred and welded, including fixing of necessary but hinges and screws and applying a priming coat of approved steel primer (CC 1:3:6) 192 Demolishing cement concrete manually / by mechanical means including disposal of material within 50 Mtr 193 Cement concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 graded Stone aggregate)62 mm thick 194 Roof top treatment to prevent water leakage of control room 195 Repairing of receiving station mesh fencing / Chain link mesh fencing height upto 8ft 196 Watering of earth pits 197 Cleaning/washing of solar panels & batteries 198 Cleaning of ACDC,DBDC Board, RTCC, Charger, Battery Bank, Solar batteries, other alike small equipments (complete Job) 199 Cleaning of 33 kV CRP using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making 33 kV CRP Vermic Proof. 200 Cleaning of 11 kV Panel using vacuum cleaner from inside with proper care, from outside with thinner/varnish and making it Vermic Proof to avoid rodent faults. 201 New 33 KV Line Fabrication , erection and painting of 15 Mtr long 33 KV Self supporting tower structure for crossing of road 202 Laying of foundation for 33 KV self supporting Tower Structure 15 Mrs. long including setting of stubs complete job 203 Erection of Channel cross arm of size 100X50X 6mm ,10 feet long and above including fixing of MS flat iron clamps with required size of bolts including punching of bolts complete 204 Erection of Channel cross arm of size 100X50X 6mm up to 09 feet long including fixing of ms flat clamps with required size of bolts including punching of bolts complete 205 Erection of Angle Iron Braces of size 65X65X6 mm,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section typeabove up to 14longcomplete 206 Erection of Angle Iron Braces of size 65X65X6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type 6 and above upto 10longcomplete 207 Erection of Angle Iron belts of size 50X50X 6 mm along with belts of same size ,fixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in cross section type upto 10 long 208 Erection of Angle Ironof size 65X65X6 mmfixing with double clamp of MS Flat including punching of bolts of Ist level to level 3rd in crossection typeabove11 long complete for guardnetting. 209 Flat iron ties 50x6 mm size 1 feet long along with fixing with cross arms 210 Erection of 33 KV Disc insulator (polymer type )with tension fittings including punching of locking pinscomplete 211 Erection of 33 KV Pin insulator with pins3 nos on top of cross arm including fixing of MS Flat Ties to rest it on , punching of base bolt /locking pin complete 212 Erection of Guy rodincluding digging of pit , Disposal of excavated soil ,refilling of excavated pits in layers of stone boulders and fine soil including fixing , adjusting properly Turn Buckle, Anchor Plate and staining screw complete 213 Carriage at site , un-bundling , Laying and stringing of ACSR DOG Conductor including making of small bundles of conductor as per site requirement, cutting in required span lengths complete (AS PER REC STANDARD) 214 Erection of anti climbing Devices at ST pole along with fixing /cutting /bending of Barbed wire, fixing with clamps 215 Erection of Danger plates 216 Route /temp path clearance by way of cleaning bushes and vegetation & making temp. pathcutting & filling for carriage of line material ( 400 mx1mx0.2m)= 80 cum 217 Watch and ward of the material and T&P round the clock i.e. 3 shifts, Rate of 1 Lab for 1 Shift 218 Route clearance for corridor of 5 m 219 Installation, testing and Commissioningof 3.15 MVA , 33/11KV Power Transformer (new work) 220 Installation, testing and Commissioning of 5 MVA& 6.3 MVA , 33/11 KV Power Transformer 221 Installation, testing and Commissioningof 10 MVA , 33/11KV Power Transformer 222 Installation, testing and Commissioning of 11kV Panel Borad with VCB Incomer(one no.) 223 Installation, testing and Commissioning of 11kV Panel Borad with VCB outgoing(one no.) 224 Setting of stubs with templates after positioning and leveling of templates excluding cost of foundations 225 Handling and Fabrication of Material in Divisional Store, Fabrication of Angle iron braces/belts /guard netting angles,fencing posts etc from angle iron of sizes 226 Fabrication of guy rods complete including turn buckle, staining screw, anchor plate, thereading of guys and staining screw 227 Fabrication of channel cross arms of sorts from MS channel of sizes , Making holes as per requirement,Punching of members and numbering on each member,Grinding of sharp edges and uneven surface of memebers and painting of members with red oxide paint. 228 Fabrication of ties, clampsfrom MS flat ( suitable for 9 mts, 11mts, and 13mts poles) 229 Fabrication of earthing plates , cable duct coversfrom MS plate as per REC drawings 230 Fabrication of earthing spikes from MS Tor steel of sorts as per REC drawings 231 Fabrication of ST poles by way of drilling of extra holes 232 Fabrication of foundation boltsfrom MS Tor steel of sorts including threading as per REC drawings 233 Fabrication of earthing pipe from GI pipe and welding of earthing plateas per REC drawings 234 Fabrication of column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures as per REC drawings 235 Shifting of channel/Angle /Flat iron at and average distance of 50mtr from unloading site to site of stacking and stacked properly. 236 Shifting of channel/Angle /Flat iron/fabricated material at and average distance of 50mtr for making space for other store material and its stacking . 237 Unloading of ST poles 9mtr in divisional store 238 Unloading of ST poles 11mtrin divisional store 239 Unloading of ST poles 13mtrin divisional store 240 Unloading of ST poles 16mtrin divisional store 241 Unloading of PCC Poles 9/8 mtr . in divisional store 242 Unloading of PCC Poles 11 mtrin divisional store 243 Unloading of PCC Poles 13 mtr in divisional store 244 Dragging/shifting of PCC/ST Pole at and average istance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 245 Unloading of ACSR Conductor dogin divisional store 246 Unloading of ACSR Conductor wolfin divisional store 247 Unloading of ACSR Conductor pantherin divisional store 248 Shifting of Old/New ACSR Conductor at and average distance of 50mtr for unloading site to site of stacking and stacked properlyand also for making space for other store material and its stacking .. 249 Unloading of 11KV VCB pannels (1+3) 250 Unloading of 11KV VCB pannels (1+4) . 251 Unloading of 11KV VCB pannels (1+5) . 252 Unloading of 11KV VCB pannels OK/Damage(1no) . 253 Unloading ofAC Board/DC Board/Battery bank/ Battery charger 254 Unloading of 33 VCB /C&R Pannel . 255 Shifting/ draggingof 11/33/66kv panel at an average distance of 50mtr for making space for other store material and its stacking also for making space for other store material and its stacking . 256 Unloading of XLPE Cable 120/185 mm² . 257 Unloading of XLPE Cable 240/300 mm² . 258 Unloading of XLPE Cable 400/630 mm² . 259 Shifting of XLPE Cable all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ... 260 Unloading of 66/33/11 KV Cable kits of different sizes 261 Shifting of 66/33/11 Cable kits of all sizes at an average distance of 50mtr from unloading site to site of stacking and stacked properly also for making space for other store material and its stacking ... 262 Unloading of Guy/GI wire/Barbed wire including carriage towards stacking site and stacked porperly. 263 Unloading of Power Transformer 3.15/4 MVA New/damage . 264 Unloading of Power Transformer 5/6.3MVA New/damage . 265 Unloading of Power Transformer 10 MVA New/damage . 266 Unloading of 11KV New/damage DistributionTransformer. 267 Dragging of 3.15/4 MVA New/damage Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 268 Dragging of 5/6.3 MVA New/damageTransformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 269 Dragging of 10 MVA New/damage Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 270 Dragging of 11kv Transformer at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking 271 Unloading ofTransformer oil Barrels. 272 Dragging ofTransformer oil old/ new barrel at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satacking also for making space for other store material and its stacking .. 273 Unloading ofMS Angle, MS Channel, MS flate ,tar steel 274 Unloading of hardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc . 275 Shifting ofhardware items such as nuts and bolts , clamps of sorts, washers,welding rods,old sarees,chain link mesh,pipe etc at an average distance of 50mtr for making space for other store material and its stacking . 276 Unloading of 33/11 KV Dics insulators. 277 Unloading of 33 KV Dics fittings 278 Shiftingof 33/11KV disc insulator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satackingalso for making space for other store material and its stacking .. . 279 Unloading of 33/11 KV Pin insulators/Guy insulator /G.I Pin. 280 Shiftingof 33/11KV pin insulator /guy/G.I Pinsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking. 281 Unloading of Cement. 282 Shiftingofcement/cement block at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking ... 283 Unloading of 33 KV CT/PTUnit . 284 Shifting of 33 KV CT/PT at an average distance of 50mtr for making space for other store material and its stacking . 285 Unloading of 11 KV CT/PTUnit includingcarriage towards stacking site and stacked porperly. 286 Shiftingof 11 KV CT/PTat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 287 Unloading of 33 KV Isolators. 288 Shiftingof 33KV Issolatorsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and its satackingand also for making space for other store material and its stacking . . 289 Unloading of 33/66 KV LAs. 290 Shiftingof 33/66KV LAsat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . 291 Unloading of 11 KV LAs/GO/HG/issolator . 292 Shiftingof 11 KV LAs/GO/HG/issolator at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 293 Unloading of PVC Cable /Control cable of different sizeincludingcarriage towards stacking site and stacked porperly. 294 Unloading of AL Paint /Red oxide paint/ Black paintincludingcarriage towards stacking site and stacked porperly. 295 Unloading of T&P Items like Drilling machine,chainPully ,Pully lifting machine ,Hand drill machine,AL ladder,welding set,tool kit,crimping tooletc 296 Unloading of Testing equipments like Meggar, Earth resitivitytester , Oil testing machine,Search Light, Turn ratio meter , multimeter etc . 297 Unloading of Safetyequipments like Safety belts, Safety shoes, Fire Extinguisher,Hand gloves, Yard lights , LED Bulbs , Rubber mat , etc 298 Shiftingof T&P /Testing / Safetyequipments at an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking .. 299 Unloading of Filter plant heavy duty 300 Shiftingof Filter plantat an average distance upto 50 mtr for stacking to accesible place for loading/unloading purpose and also for making space for other store material and its stacking . 301 Loading of PCC Poles 9/8 mtr 302 Loading of PCC Poles 11 mtr 303 Loading of PCC Poles 13 mtr 304 Loading of ST poles 9mtr 305 Loading of ST poles 11mtr 306 Loading of ST poles 13mtr 307 Loading of ST poles 16mtr 308 Loading of ACSR Conductor dog 309 Loading of ACSR Conductor wolf 310 Loading of ACSR Conductor panther 311 Loading of Cement 312 Loading of 11 KV VCB 1+3 Pannels 313 Loading of 11 KV VCB 1+4 Pannels 314 Loading of 11 KV VCB 1+5 Pannels 315 Loading of 11 KV VCB 1 Pannel OK/Damage 316 Loading of AC Board/ DC Board/Battery charger /Battery bank 317 Loading of 33KV VCB 318 Loading of 33KV C&R Pannels 319 Loading of XLPE Cable 120/185 mm² 320 Loading of XLPE Cable 240/300mm² 321 Loading of XLPE Cable 400/630 mm² 322 Loading of Cable kits of different sizes 323 Loading of Guy/GI wire/Barber wire 324 Loading of Power Transformer 3.15/4.0 MVA 325 Loading of Power Transformer 5.0/6.3 MVA 326 Loading of Power Transformer 10 MVA 327 Loading of 11 KV DistributionTransformer 328 Loading of Transformer Oil barrels 329 Loading of MS Angle iron braces, MS channel cross arms, Guy rod, Earthing spikes, MS Flate 330 Loading of hardware items such as nuts and bolts, clamps of sorts,washers,welding rods,old sarees,chain link mesh,pipe 331 Loading of 33 /11KV Disc insulator 332 Loading of 33 KV Disc fitting 333 Loading of 33/11 KV Pin insulator /Guy insulator /G.I Pin 334 Loading of 33 KV isolator 335 Loading of 33 KV LA 336 Loading of 11KV Isolators 337 Loading of PVC Cable /Control cable of different size includingcarriage from stacked site. 338 Loading ofAL Paint /Red oxide paint/ Black paint 339 Loading ofFilter plant heavy duty 340 Carriageof Fabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etc towards stacking site and stacked properly 341 Loading ofFabrication column structures, beam structure, isolator structures,LA ,CT,PT and PI Structures etcincludingcarriage from stacked site. 342 Loading of 33 KV CT/PT units 343 Loading of 11 KV CT/PT units 344 Loading of T&P Items like Drilling machine,chainPully ,Pully lifting machine, Hand drill machine,AL ladder,welding set,tool kit,crimping tooletc units 345 Loading of Testing equipments like Meggar, Earth resitivitytester , Oil testing machine,Search Light, Turn ratio meter , multimeter etc units 346 Loading of Safetyequipments like Safety belts, Safety shoes, Fire Extinguisher,Hand gloves, Yard lights , LED Bulbs , Rubber mat , etcunits 347 Shifting of allied materials for making space for porper stacking of material 348 Carriageof Fabrication material from fabrication site towardsstacking site and proper stacking of material. 349 Repair of store shed by way of replacement of damaged CGI sheets, repair of CGI sheets by way of welding, replacememt of hooks, nuts and bolts, tightening of nuts bolts and hooks and welding . 350 Collection andcarriage of T&P items to working site and back crriage of T&P after job 351 Sorting of material by way of weighing / measuring and inspection of material and then carriage from weighing / measuring and inspection site to site of fabrication 352 painting of store shed with red oxide/Al paint single coat 353 Checking/Measuring/ Inspection/Meggering ofXLPE Cable/Control cable by way of unreal and after work agian rereelingon drum 354 Checking/Measuring/ Inspection ofACSR Conductorby way of unreal and after work agian rereelingon drum 355 Complete testing/ispection of pannels including relay testing , interconnection,charging polarity etc during issue/receipt/verification. 356 Prototype errection of Gantry /Beam/CT/PT/Isolator sturcture 357 Dismentling of ACSR Dog Conductor 358 Dismentling of ACSR Wolf Conductor 359 Dismentling of ACSR Panther Conductor 360 Dismentling of 3.15 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 361 Dismentling of 6.3 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 362 Dismentling of 10 MVA, 33/11 KV Power Transformer including dismentling of Cables, Radietors, drainage of Oil and filling in empty Barrels 363 Dismentling of 11 KV Panel Board with VCB (Incommer) 364 Dismentling of 11 KV Panel Board with VCB (Outgoing) 365 Installation of SMPS & CMR on Smart Meters 366 Installation/Replacement of Smart Meters
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 32
Jammu And Kashmir View Result →
47.
Agriculture #9300924 Technical Bid
Supply Of Electrical Items General For Sugar Mill , Push Button Element 1No+1Nc L&T Make , Single Phase Tester Taparia Make Size 6 , Real Isulator For Cane Unloader Size 6” , Shackle Insulator For Ltline Protection , Connector Link Elmax Make Size 6 Mm , Dobut Size 16 Mm , Dobut Size 25 Mm , Dobut Size 35 Mm , Dobut Size 50 Mm , Pvc Steel Grip Plus Tape Size 3 / 4” Length 10 Mtr , Cotton Tape Size 3 / 4” , Porceline Kit Kat Standard 20Amp. 240Volt , Dobut 32Amp. 240Volt , Dobut 32Amp. 440Volt , Bowel Element 750 Watt , Soldring Iron 35W ( Soldron Make ) , Soldring Paste , Soldering Wire 0-10 Swg Bharati 80%& 20% , C.R.C. 2-26 ( 300 Ml ) , Insulatingvarnish Dr.Back Make Elmoluft 1A , Varnish Bectrol Grey / Red ( Dr. Back Make ) , Thinner Dr. Backmake 218 For V-155 , Dobut 205 For V-155 , Dobut 234 For V-155 , Hevey Duty Couper Winding Havels Force-10 Exhaustfan 18”, 250V , 1500 Rpm. Single Phase , Dobut 24” , 240V , 1000 Rpm. Three Phase , Dobut18” , 250V , 1500 Rpm. Three Phase , Do But 12” , 250V , 1500 Rpm. Single Phase , Do But 24” , 240V , 1000 Rpm. Single Phase , Blower Fan 2900 Rpm. ( Boss Make ) , Push Button Green / Red Size 32Mm ( L & T Make ) , Push Button Elementno & Nc, 32Mm ( L&T Make ) , Push Button Station Colour Light Grery / Rad, Onoff , Bulbs 24V 60 Watt , Bulbs 24V 100 Watt , Fuse Base 32Amp, 63Amp. 125Amp, 160Amp. 250Amp. L&T Make , Do 400 Amp. L& T Make , Do630 Amp. L & T Make , Condensor 4 Mfd, 440 V, Tibcon Make , Do 2.5 Mfd Tibcon Make , Do 3.15 Mfd Tibcon Make , Condensor 8 Mfd Tibcon Make , Do 10 Mfd Tibcon Make , Do 20 Mfd Tibcon Make , Do 25 Mfd Tibcon Make , Do 33 Mfd Tibcon Make , Do 50 Mfd Tibcon Make , Do 80 Mfd Tibcon Make , Do 100 Mfd Tibcon Make , Milimax Paper 7 Mile , Milimax Paper 5 Mile , P.T. Holder 100 Watt Anchor Make , S.C. Holder 100 / 200 Watt Jyoti / National Make , Do But 300 / 500 Watt , Combination Plier 8” Taparia Make , Tube Side Holder Backlite Stand Single / Double , Three Pin Porceline Holder For 125 Hpmv Lamp , Tube Lite Rotary Holder Base ( Single Fitting ) , Tube Lite Rotary Holder Base ( Double Fitting ) , Indicator Lamp 40 Lad , Change Over Switch Standard 63 Amp 440V, Hpl Make With Tc. , Change Over Switch Standard 100 Amp 440V Off Line Hpl Make With Tc. , Change Over Switch Standard 200 Amp 440V Off Line Hpl Make With Tc. , Change Over Switch Standard 400 Amp 440V Off Line Hpl Make With Tc. , Change Over Switch Standard630amp 440V Off Line Hpl Make With Tc. , C.T.C. 400 Ml , Sc Holder 300 Watt For Sodiam Hanging Light , Pvc Motor Cooling Fan I H.P. , Do 03 H.P. , Do 05 H.P. , Do 7.5 / 10 H.P. , Do 15 H.P , Do 20 H.P , Do 25 H.P. , Do 30 H.P. , Empire Tape 1” Of Mt , Empire Tape 3 / 4” Of Mt , Glass Tape 1” Ofmt , Glass Tape 3 / 4” Ofmt , Semi Conductor Fuse Gec Make 1000 / 850 / 630 / 300 / 250A, 600V , Potententio Meter 2Ko-5410-10 Pankaj / Pawan Make 2K5-500W , Fuse Carriar 125Amp Vaishno Make , Timer Em-2000, 4-120 Sec 240 Vac, 50Hz Gic Make , Fuse Holder 160Amp. ( Hb-160 Type ) L&T Make , Fuse Holder 63 Amp. ( Hk-63 H Type ) L&T Make , Fuse Holder 32Amp. ( Hk-32 H Type ) L&T Make , Fuse Holder 20 Amp, ( Hd-20 H Type ) L&T Make , Fuse Link 63Amp. ( Hq Type, A- 3 Size ) L&T Make , Fuse Link 32Amp. ( Hq Type, A- 3 Size ) L&T Make , Fuse Link 20Amp. ( Hg Type, F- 1 Size ) L&T Make , Led Indicator Size 22.5Mm Red Colour L&T Make , Led Indicator Size 22.5Mmcgreen Colour L&T Make , Led Indicator Size 22.5Mm Yellow Colour L&T Make , Bush Button Mushroom Head 30Mm Dia L&T Make , Push Button Station 1No+1Nc L&T Make , Multi Step 2Way Switch 16 Amp. With Off L& T Make , Multi Step 3Way Switch 16 Amp. With Off L& T Make , Multi Step 6Way Switch 16 Amp. With Off L& T Make , Multi Step 9 Way Switch 25 Amp. With Off L& T Make , Ammeter Selector Switch 16Amp. L&T Make , Voltmeter Selector Switch 16Amp. L&T Make , Flag Handle 16 Amp. Size 48X48, 48X60 Cat.No.- Knfhs2 L&T Make , Glass Fuse20mm , 01Amp To 10Amp. , Element 250Watt , Do But 150Watt , Semi Conductor Fuses 1250 Amp., 660V, 170L 7035 38T / 50 90415 Ty Power Silicon / Bushmen Denmark Make , Do460amp. 660V, Gsmj / 170M 5239-500 Mp.1000V , Do 460Amp. 660V, Gsmj / 170M 5239-500 Amp.1000V , Semi Cunductor Fuse 700 Amp., 690 Volt, 170 M 6111 Bushmen Denmark Make , Diode Rectifier 321Um 100G, Forward ( Rir Make ) , Diode Rectifier 321Umr 100G, Reverse ( Rir Make ) , Diode40hm 120G, Reverse / Forward ( Rir Make ) , Bridge Rectifier25amp. ( Rir Make ) , Pvc Connection Elemax Make Cts750v 35A , Do But 25A , Do But 16A , Do But 10A , Automatic Voltage Regulator With Time Delay , Digital Multimeter Meco Make , Proximaty Sensor Switch10-30 V. D.C. Size-18Mm, 24V, Pnp Magnum Make , Proximaty Sensor Switch 10-30 V.D.C., Size -30Mm24v, Pnp Magnum Make , Glass Sleeve Size 1 Mm , Glass Sleeve Size 2 Mm , Glass Sleeve Size 3 Mm , Glass Sleeve Size 4 Mm , Glass Sleeve Size 5 Mm , Glass Sleeve Size 6 Mm , Glass Sleeve Size 8 Mm , Glass Sleeve Size 10 Mm , Glass Sleeve Size 12 Mm , Glass Sleeve 25 Mm , Glass Sleeve 35 Mm , Glass Sleeve 50 Mm , Glass Sleeve 70 Mm , Fuse Link Ee Make 32 Amp. , Fuse Link Ee Make 63 Amp. , Potentio Meter 2K- 50Hm Rw-3K , M.C.B. Double Pole 20 Amp L&T Make , Do 6 Ampl&T Make , Do 10 Amp L&T Make , Do 16 Amp L&T Make , M.C.B. Double 3 Pole 32 Amp L&T Make , M.C.B. Double 3 Pole 63 Amp L&T Make , M.C.B. Double 3 Pole 100 Amp L&T Make , M.C.B. Double 3 Pole 125 Amp L&T Make , M.C.C.B.Double 3 Pole 160Amp L&T Make , M.C.C.B. D Sine 3 Pole250 Amp L&T Make , M.C.C.B. D Sine 3 Pole 400 Amp L&T Make , M.C.C.B. D Sine 4 Pole 630 Amp L&T Make , M.C.C.B. D Sine 4 Pole 800 Amp L&T Make , A.B. Contactor Lcid / 73 16 Amp With Auxiliary Block , Push Buton Element Teknik Make , Potentio Meter2k5 3W Pankaj Make , T.C.Contactor 2No+2Nc With Aux. Block , T.C.Timer 0-30 Sec. Contactor Mount On / Off Delay , Indicating Lamp 7 / 10W With Lamp 220V ( Pin / Screw Type ) , Push Button Station With Box L&T Make , Hrc Fuse Link 32 Amp. Ee Make , Bkt Kit Kat Fuse Assly.. 63A Ee Make , Amp. Meter 0-5000Amp. Ctr 4300 / 5 1450X1450mmae , Kw Meter 0-3000Kw 1450X1450mm Ctr 4300 / 5Ae / L&T , Moving Arching Contact For 300A Ocb Mei Make , Dobut 400 Amp , Timer 0-60 Sec.Single Stage Bch Make , Timer 0-120 Sec. Double Stage Bch Make , Heavy Duty Limit Switch, General Purpose Cat Code Llgs Angular Liver , Power Capacitor Heavy Duty 3 Phase, 525 Volt, Box Series -Lt Bch , 25Kvar L&T Make With Test Certificate , Relay For Automatic Power Factor Controller 12 Stage , Carbon Bush Holder For Cane Unloader20 X 20 X 100Mm , Digital / Analog D.C. Ammeter 0-1500Amp.Ae / L&T Make Esd 1Ma 1.5 , Digital / Analog D.C. Ammeter ( Alolog / Digital ) 20-0-20 As 1248, Fsd 70-0-70 Mvm 96 Ae / L&T Make , Digital / Analog D.C. Voltameter 0-600V, M96, S1248, Fsd-1Ma Ae / L&T Make , Digital / Analog D.C. Voltameter M-96, S-1248, Fsd-1 Ma Ae / L&T Make , Slipring Suitable For 200 Hp Slipring Motor Bore 51Mm Ring Od 145Mm , Spare For Advance Make Ocb Type N2 Rating 300Amp.Spare Arching Contact , Do But Spare Moving Contact , Do But Spare Fixed Contact , Techo Generator Model Dtg 4000 Output 200 Vtc / 4000 Rpm Maximum 400Mm Ador Make , Power Block Thyristor Type Tt75n / Mcc501-16102 Dixys , Thyristordcr, 1004 S / D 1616 Itly Make , Thyristordcr, 806 / 807 Itly Make , Wolfmake Drill Machine , Slipring Holder For 200 Hp Motor , Slipring 5 Hp Kec Motor Id 500Mm , Change Over Switch 630A, 4 Pole S.S. Hpl With Test Certificate , Motor Connection Plate 120 / 90Hp Slipring Motor ( Kec ) , Motor Connection Plate 55Hp Slipring Motor ( Jyoti ) , Motor Connection Plate 33Hp Slipring Motor ( Kec ) , Motor Connection Plate 55Hp Slipring Motor ( Ngef ) , Slipring Holder 110 Kw Ngef Make Motor , Slipring Holder 200Hp Aei Make Motor , Dowells Paste , R.P.M. Meter Suitable For Thyrister Convertor Pannel ( D.C.Pannel ) Fsd Ima M-96 Meco Size 1200-0-1200Rpm , Digitalsingle Phase Ammeter Flush Mounting 96 X96 Mm L&T Make , Led Friquency Meter Flush Mounting 96X96mm L &T Make , C.T.S. For Ratio 200A Ctr-200 / 5 , C.T.S. For Ratio 100A Ctr-100 / 5 , C.T.S. For Ratio 60A Ctr-60 / 5 , C.T.S. For Ratio 300A Ctr-300 / 5 , C.T.S. For Ratio 400A Ctr-400 / 5 , Volt Meter Ae Make For 0-500V Ac Size 140X140mm L&T Make , Volt Meter Ae Make For 0-500V Ac Size 95X95mm L&Tmake , Amp. Meter 1000Amp Ctr 1000 / 5 Size 95 X 95 L&T Make , Amp. Meter 400Amp Ctr 500 / 5 Digital / Analogl&T Make , Amp. Meter 250Amp Ctr 250 / 5 Digital / Analogl&T Make , Amp. Meter 300Amp Ctr 300 / 5 Digital / Analogl&T Make , Timer Coil 110 Volt Bch Make , Timer Coil 220 Volt Bch Make , Pneumatic Timer, Coil-220V Ac, Type-Pcn, Range-05-60 Sec With Double Contact Block ( 1No+1Nc ) Cat Code- Krtpcn 11A-1 , Pneumatic Timer, Coil-110V Ac, Singlehead Wigh ( 1No+1Nc ) Timing Range - 0.1 -60 Sec On Dely 110 Volt Cat Code- Krtpn 10 A- 1 , Potentio Meter Ec Make 5Ka Type 5710 , M.C.B. Havells Make16 Amp , M.C.B. Havells Make20 Amp , Bkt Kit Kat 63 Amp L&T Make , Bkt Kit Kat 32 Amp L&T Make , Bkt Kit Kat 16 Amp L&T Make , S.S.Tension Spring For 500 Hp Motor C.B.Holder , 3 Phase Cooling Fan For 100 Kw Thyrister , M.S.Star Coupling As Per Sample , Carbon Brush Holder For Techo Generator As Per Sample , Bkt Fuse Carrior 125 A L&T Make , Power Thyristor 7 T 75 N , D.C.I.A.Mk-Iii Kec Make , New Work Cardkec Make , Bearing For Techo Generator Big Size , Bearing For Techo Generator Small Size , Indicating Lamp 220 V Dc Bch Make , Heating Element Rod 2000 W 2” / 1” , Pressure Switch 4.5 Kgs Indofos Make Ips 70 , Digital Clamp Meter ( Tingue Tester ) 1000A Motwani Make , Continuity Tester With Cell , Avr3 Phase 415 Volt 10Amp. Kirloskar / Nova / National Make , Soldering Strip ( Lead Tin 60:40 ) , Soldering Wire 18 Swg , Soldering Flux Frysol Cooleson India Limited Make , Hydro Meter For Battery Reading , Copper Flexible Lead With Fibre Glass Insulated 10 Mm , Copper Flexible Lead With Fibre Glass Insulated 25 Mm , Copper Flexible Lead With Fibre Glass Insulated 35 Mm , Copper Flexible Lead With Fibre Glass Insulated 50 Mm , Mcb Tp 63 Amp Havells / L&T Make , Mcb Tp 32 Amp Havells / L&T Make , D.P.Switch 32 Amp Anchor / Havells / L&T Make , Heating Rod 1000 Watt 2 Ft. Long , Heating Rod 1000 Watt 1 Ft Long , Backelite Sheet 20 Mm 4’ X 4’ , Carbon Brush For Grinder , Tpn Switch 63 Amp Havells / L&T Make , Axial Blower Fan For 700 Hp Thyrister Control Panel Thyrister Modular Make E.B.M. Module Azd-250, Aa-08-19254 / 440 Volt 60 Hz 2900 Rpm Made In West Germany , Magger For 500 Volt Mannual Operating , Heating Rod Of 2000 Watt 3 Feet Long U Shape , Handle For Acb 3200 Amp Type Draw Out Cncs , Carbon Brush Holder For 7.5 Hp Motor , Nomex Paper F- Class 7 Mile , White Paper7 Mile , Carbon Bush For Grinder4 Inch , Carbon Bush For Grinder7 Inch , Carbon Brush For Techo Generator , Fibre Fix Plate Suitable For Credle Assembly For Above L&T Make A.C.B. , Carbon Brass Holder For 562 Kw Kec Make Dc Motor , Carbon Brass Holder For 700 Kw Kec Make Dc Motor , Carbon Brass Holder Heavy Duty For 56.2 Kw Ie Make Dc Motor , Carbon Brass Holder Heavy Duty For 160 Kw Ie Make Dc Motor , Carbon Brass Holder Heavy Duty For 172 Kw Kec Make Dc Motor , Carbon Brass Holder Heavy Duty For 300 Kw Kec Make Dc Motor , Carbon Brass Holder Heavy Duty For 350 Kw Kec Make Dc Motor , Carbon Brush Round , Carbon Brush Squire , Carbon Press Tensionspring Heavy Duty For 200Hp , Carbon Press Tensionspring Heavy Duty For 700Hp , Carbon Press Tensionspring Heavy Duty For 173Hp , Carbon Press Tensionspring Heavy Duty For75hp , Digital Megger 1000V, 1000Mr Motwani / Rishabh Make , S.T.Bulb 300 Watt , S.T.Bulb 500 Watt , Auto Manual Selector Switch 2 Pole 2 Way L&T Make , Current Transformer 400 / 5A, 15 Va Clean-1 , Terminal Plate ( Assembly ) For Acb , Digital Energy Meter 415 Volt , C.T. 200 / 5Select Make , Connection Plate For 4 Speed Meter , Mcb Box For 63 Amp, 32Amp, 20Amp , Element For Timer Double Stage , Exhaust Fanblade Size 18 , Exhaust Fanblade Size 24 , Under Voltage Release ( Uvr 415 V, Ac ) For Acb -3200 Cncsl & T Make , Shunt Releasetype Ea- 24 / 48 V, Dcfor Acb -3200 Cncsl & T Make , Open Coil 220 Volt , Closing Coil 220 Volt , Plate ( Complete Coil Set ) , Ethernet Cable 03 Mtr , Cdp Connector , Thyrister ( Mcc501-16102 ) Dixys Make , Dc Volt Meter 0-600V Meco Make , Ampear Meter 0-500A Meco Make , Potentio Meter 2.5 Kvr , Thyrister Dcr-807 , Igbt With Thyrister For Above , Copper Lugs Heavy Duty Size 50 Sq. Mm Dowells Make , Copper Lugs Heavy Duty Size 70 Sq. Mm Dowells Make , Copper Lugs Heavy Duty Size 95 Sq. Mm Dowells Make , Copper Lugs Heavy Duty Size 120 Sq. Mm Dowells Make , Copper Sector Connectorheavy Duty Size 50 Sq. Mm Dowells Make , Copper Sector Connectorheavy Duty Size 70 Sq. Mm Dowells Make , Copper Sector Connectorheavy Duty Size 95 Sq. Mm Dowells Make , Copper Sector Connectorheavy Duty Size 120 Sq. Mm Dowells Make , Al. Sector Lugs Long Barrelsize 25 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 35 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 50 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 70 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 95 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 120 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 150 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 185 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 240 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 300 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 400 Sq.Mm. Dowells Make , Al. Sector Lugs Long Barrelsize 630 Sq.Mm. Dowells Make , Al. Sector Connectorssize 50 Sq.Mm. Dowells Make , Al. Sector Connectorssize 70 Sq.Mm. Dowells Make , Al. Sector Connectorssize 95 Sq.Mm. Dowells Make , Al. Sector Connectorssize 120 Sq.Mm. Dowells Make , Al. Sector Connectorssize 150 Sq.Mm. Dowells Make , Al. Sector Connectorssize 185 Sq.Mm. Dowells Make , Al. Sector Connectorssize 240 Sq.Mm. Dowells Make , Al. Sector Connectorssize 300 Sq.Mm. Dowells Make , Al. Sector Connectorssize 400 Sq.Mm. Dowells Make , Al. In Lineconnectorssize 25 Mm Sq. Dowells Make , Al. In Lineconnectorssize 35 Mm Sq. Dowells Make , Al. In Lineconnectorssize 50 Mm Sq. Dowells Make , Al. In Lineconnectorssize 70 Mm Sq. Dowells Make , Al. In Lineconnectorssize 95 Mm Sq. Dowells Make , Al. In Lineconnectorssize 120 Mm Sq. Dowells Make , Al. In Lineconnectorssize 95 Mm Sq. Dowells Make , Al. In Lineconnectorssize 120 Mm Sq. Dowells Make , Al. In Lineconnectorssize 150 Mm Sq. Dowells Make , Al. In Lineconnectorssize 185 Mm Sq. Dowells Make , Al. In Lineconnectorssize 225 Mm Sq. Dowells Make , Al. In Lineconnectorssize 240 Mm Sq. Dowells Make , Al. In Lineconnectorssize 300 Mm Sq. Dowells Make , Al. In Lineconnectorssize 400 Mm Sq. Dowells Make , Al. In Lineconnectorssize 630 Mm Sq. Dowells Make , Corrosion Inhiviting Comopond ( Gtz8785 ) Dowells Make , 1.5 Ton Split Ac Model No. Asga18dmwa ( O- General Make ) , 1.5 Ton Windo Ac Model No. Asgb180awa ( O- General Make ) , Control Card ( Con-4 ) , Power Card ( Pin-4 ) , Power Card ( Pin-51 ) , Dsl Card , Control Card For Vfd ( 2Nd Rake Cane Carrier ) , Carbon Bush ( Asam Carbon Make ) , Carbon Bush Size 25 X40 X 50Mm Eg-224 ( Asam Carbon Make ) , Carbon Brush Size 20 X 40 X 50Mm Eg-224 ( Asam Carbon Make ) , Do But 13 X 32 X 40Mm Eg-224 ( Asam Carbon Make ) , Do But 12.5 X 32 X 40Mm Eg-224 ( Asam Carbon Make ) , Do But 16 X 32 X 40Mm Eg-224 ( Asam Carbon Make ) , Carbon Bush Size 20 X 20 X 100Mm Eg-224 ( Asam Carbon Make ) , Carbon Bush Size 12 X 25 X 30Mm Eg-224 ( Asam Carbon Make ) , Carbon Bush ( Copper Mixed ) For Slipring Motor 25 X 50 X 60Mm Bh-51 Asam Carbon Make , Do But 22 X 32 X 40Mm Bh-51 , Do But 5 X 19 X 25Mm Bh-51 , Do But 16 X 32 X 40Mm Cb-6 , Do But 20 X 40 X 50Mm Cb-6 , Graphite Carbon Bush ( In Two Pcs ) Size 45 X 40 X 20Mm Asam Carbon Make , Power Board For Analog Panel Srp-660 ( 700 Hp ) , Control Card For Analog Kirlosker Panel 700 Hp ( D.C. Motor ) , Net Work For D.C. Drive Panel Kirloskar Make , Pow-4 For D.C.S.800, 2000 Amp. , Con-4 For D.C.S. 800, 2000Amp. , Fex-4 For D.C.S. 800, 2000Amp. , Pin-51 For D.C.S. 800, 2000Amp. , Pin - 48For D.C.S. 800, 2000Amp. , Dscl Card , Pin - 4For D.C.S. 800, 520Amp. , Con-4 For D.C.S. 800, 520Amp. , Power Card For D.C.S. 880 , Control Card Fro D.C.S. 880 , Field Card For D.C.S. 880 , Aint Card For Acs 800 , Igbt Card For Acs 800 , Power Card For Acs 800 , Control Card For Acs 550 , Power Card For Acs 550 , Resistance Box For Leveller Motor- 250H.P. Techanical Specificatrion Type Of Grid- Punched Grid, Colling - Nauural Air Coolded, Resister Material - Stairless Steel / Techral, Enclosure- Sheet Metal ( Galvanished ) , Mounting- Floor Mounting Horizontal, Cable Entry- Bottom, Protection Degree- Ip-20 / Ip-21 / Ip-23 / Ip-33, Over Ambient Temp- 375 C, Currentrating- 8Amp To 3000Amp., Voltage - 600 Volt, Terminal - 12 Nos Pole-04 , Pcc Pole 8.5Mtr Long , Rabit Conductor , Weasel Conductor , Clamp With Nut & Bolt , Earthing Pole , Stay Set Complete , Saukel Insulator , Phase Tester Taparia Neon Bulb Tester ( 813 ) Taparia Make
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Uttar Pradesh View Result →
48.
Power #9158096 Technical Bid
Rate Contract For Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Stations Along With Their 66 / 33 Kv Lines And Fabrication & Handling Of Material Of Divisional Store Under The Jurisdiction Of Sub Transmission Division, Jpdcl, Kathua For The Year 2022-23 Or Till The Next Contract.- 1 Erection Of 16 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 2 Erection Of 13 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 3 Erection Of 11 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 4 Erection Of 11 Mtr Long Pcc Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 5 Erection Of 9 Mtr Long Steel Tubular Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 6 Erection Of 9 Mtr Long Pcc Pole With Planting Depth Of 1 / 6 Th Of The Height Of The Pole Including Digging Of Pits, Disposal Of Extra Earth, Collection Of Boulders And Filling Back. 7 Painting Of 16 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 8 Painting Of 13 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 9 Painting Of 11 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 10 Painting Of 09 Mtr Long Steel Tubular Poleincluding Fixtures With One Coat Of Red-Oxide And Two Coats Of Silver ( Aluminium ) Paint 11 Cement Bottoming In 1:2:4 Mix Including Excavation And Form Work As Per Rec Standards. ( 16 / 13 / 11 / 9 Mtr Long Poles ( Complete Job ) 12 Fixing Of Galvanisedspiral Earthing Of Swg No. 8, G.I Wire Of 115 Turns Confirming To Rec-J1 Construction Standard, ( J1 ) 13 Fixing Of 66 / 33Kv Galvanised Guy Set ( Guy Wire, Guy Rods, Turn Buckle Plate , Guy Insulators ) Confirming To Is 2141 / 1979 Or The Latest Version Thereof Including Digging Of Pits & Refilling 14 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 100Mm2 Acsr Conductor ) 15 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 150Mm2 Acsr Conductor ) 16 Collection Of Snapped Acsr Cond. And Re-Stringing, Tensioning , Binding Of Acsr Conductor, ( 200Mm2 Acsr Conductor ) 17 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) Up To Distance Of 50 Mtr 18 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) Up To Distance Of 50 Mtr 19 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) Up To Distance Of 50 Mtr 20 Dismantling Of Pcc Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) Up To Distance Of 50 Mtr 21 Dismantling Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 22 Dismantling Of Pcc Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 23 Dismantling Of Three / Four Pole Structure, Opening Of Channels, Crossarms, Angles ( Complete Job. ) 24 Dismantling Of Two Pole Structure, Opening Of Channels, Crossarms, Angles ( Complete Job. ) 25 Straightening Of Tilted Steel Tubular Pole ( 16 Mtr. Long ) 26 Straightening Of Tilted Steel Tubular Pole ( 13 Mtr. Long ) 27 Straighteningof Tilted Steel Tubular Pole ( 11 Mtr. Long ) 28 Straighteningof Tilted Pcc Pole ( 11 Mtr. Long ) 29 Straighteningof Tilted Steel Tubular Pole ( 9 Mtr. Long ) 30 Straighteningof Tilted Pcc Pole ( 9 Mtr. Long ) 31 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) Up To Distance Of 50 Mtr 32 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) Up To Distance Of 50 Mtr 33 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) 34 Unloading Of Steel Tubular Pole Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) Up To Distance Of 50 Mtr 35 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 16 Mtr. Long ) 36 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 13 Mtr. Long ) 37 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 11 Mtr. Long ) 38 Loading Of Steel Tubular Poles Including Carriage Up To Dumping Site, ( 9 Mtr. Long ) 39 Extra Carriage From Dumping Site, ( 16 Mtr. Long ) Up To Site Of Work 1St 100 Mtr 40 Extra Carriage From Dumping Site, ( 13 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 41 Extra Carriage From Dumping Site, ( 11 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 42 Extra Carriage From Dumping Site, ( 9 Mtr. Long ) Up To Site Of Work Ist 100 Mtr 43 Unloading Of Steel Of Sorts , ( Steel ) 44 Loading Of Steel Of Sorts , ( Steel ) 45 Unloadingof Conductor Reels, ( 100Mm² / 150Mm² / 200Mm² Acsr Conductor ) 46 Loadingof Conductor Reels, ( 100Mm² / 150Mm² / 200Mm² Acsr Conductor ) 47 Fixing Of 66-33 Kvdiscinsulator ( 70 Kn ) 2008 Standards, ( Porcelain ) 48 Fixing Of 66-33 Kv Disc Fitting ( 70 Kn ) 2008 Standards, ( Polymer ) 49 Fixing Of 66-33 Kv Insulators ( 10 Kn ) Standards, ( Porcelain ) 50 Fixing Of 66-33 Kv Pin Insulators ( 10 Kn ) Suitable For 100 / 150 / 200Mm² Acsr Conductor. 51 Replacement / Fixing Of 66-33 Kvtension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 52 Replacement / Fixing Of 66-33 Kv Tension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 150M² 53 Replacement / Fixing Of 66-33 Kv Tension Fittings ( Socket & Ball Type Or T&C Type ) For Acsr 200M² 54 Straighteningof X-Arms Of Different Sizes ( 100X50x50x6 Mm Channel Iron, 50X50x6mm Angle Iron ) Duly Painted With One Coat Of Red-Oxide And Two Coats Of Silver Paint Fixing With Different Sizes And Sorts Of Nuts, Bolts And Washers, ( Channel Iron X-Arms, Angle Iron-X-Arms, Pole Tops ) 55 Straighteningof Angle Ironof Different Sizes ( 65X65x6 Mm Channel Iron, 50X50x6mm Angle Iron 56 Repair And Re-Erection Of Cradle For Guard Netting With Gi Wire 8No Including Wire Binding, Cutting / Bending Of Gi Wireas Per Rec Standards 57 Branch Cutting, 66- 33 Kv Lines 58 Removing Of Wild Climbers / Vegetation Around 66 / 33 Kv Poles 59 Removing Of Wild Climbers / Vegetation Around 66 / 33 Kv Tower 60 Removing Of Wild Climbers From Top Of 66-33 Kv Lines. 61 Removing Of Wild Climbers From Peak, Cage, Cross Arm Of 66-33 Kv Old Tower Line 62 Patrolling Of 66 / 33 Kv Line ( Routine / Under Fault ) 63 Tightening Of Loose Guys 64 Dismantling & Re-Erection Of Damaged Guys Including Digging Of Pit & Refilling The Same 65 Replacement Of Damaged Disc Insulator In Tension String 66 Replacement Of Cross Arms Of Sizes 100X50x6 67 Replacement Of Angle Iron Of Sizes ( 65X65x6, 50X50x6 ) 68 Replacement Of Pin Insulator On Four / Three / Double Pole Structure 69 Replacement Of Pin Insulator On Single Pole Structure 70 Replacement Of Worn-Out / Damaged Jumper Of 66-33 Kv Towerlines 71 Replacement Of Disc Insulator, Suspension Fitting Of 66-33 Kv Towerlines 72 Replacement Of Worn-Out / Loose / Damaged Jumper Of 66-33 Kv Lines ( Sets Of3 Nos ) 73 Local Earthing Of 66 / 33 Kv Lines By Way Of Using Discharge / Earth Rods At Faulty Site To Avoid Accident Due To Any Induction While Working On Line. 74 Tightening / Restringing Of Loose Acsr Dog 100 Mm2 75 Tightening / Restringing Of Loose Acsr Wolf 150 Mm2 76 Tightening / Restringing Of Loose Acsr Panther200 Mm2 77 Dismantling & Re-Erection Of Acsr Dog 100Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 78 Dismantling & Re-Erection Of Acsr Wolf 150Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 79 Dismantling & Re-Erection Of Acsr Panther 200Mm2 Including Collection Of Dismantled Conductor , Making Of Small Bundles And Its Carriage 80 Dismantling Of Stay Sets Complete 81 Upkeep / Maintenance Of 66-33 / 11 Kv Receiving Sub Stations A ) Routine Maintenance Of 66 Kv Outdoor Sf6 By Way Of Tightening Of Loose Nuts And Bolts, Greasing / Lubrication Of Movable Parts, Checking The Movable Alignment Of Different Phases, Cleaning Of Insulating Chambers, Etc 82 33 Kv Vcb Repairs & Renovationby Way Of B ) Setting Of Mechanical Assembly / Replacement Of Damaged Spring / Repair Of Locking & Charging System 83 C ) Replacement Of Tripping Coil / Closing Coil 84 D ) Replacement Of Damaged Vacuum Interrupter 85 E ) Replacement Ofbushing Including Clamps 86 66 Kv C&R Panel: Replacement Of Different EquipmentSa ) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch , Selector Switchidentification Of Panel Wiring Faults & Its Rectification 87 33 Kv C&R Panel: Replacement Of Different EquipmentSa ) Ammeter, Volt Meter Indication , Lamps, Fuses, Trip Close Switch , Selector Switchidentification Of Panel Wiring Faults & Its Rectification 88 B ) Replacement Of Different Relays - Mitnumerical Relay / Electro-Mechanical Relay / Master Trip Relay / Differential Relay / Auxiliary Relay Etc. 89 Installation, Testing, Commissioning Of 66-33 Kv Control Relay Panels ( Complete Job ) 90 Complete Testing Of Relays Setting Of Testing Kit, Interconnection Between Various Points Of Panel With Respect Tosecondary Injection Key On Various Current Taps, Recording The Observation Thereof. All Modifications Necessary To Achieve Desired Results. 91 Control Cable Replacement Of Damagedcontrol Cables Of All Typesincluding Binding With Pvc Belts / Binding Wire, Peeling Of Insulation And Fixing Of Proper Size Thimble Connecting The Cable After Identification Of Each Core To Both Ends I.E. Panel To Cts / Panel Topts / Panel To Breaker And Making Functional Of 33 Kv Outdoor Breakers, Protection , Alarms, Annunciation ( Complete Job ) 92 Upkeep Of Earthing Of Aux. Transformer 93 Upkeep Of Earthing Of Power Transformer 94 Upkeep Of Earthing Of 66 / 33 / 11 Kv La 95 Providing Of Extra Earthing For Improvement Purpose ( Complete Job ) 96 Upkeep Of Earth Mat Of Out Door Yard 97 Replacement Of Damaged Earth Mesh In Sub-Station As Per Approved Map & Design. 98 Excavation Of Trenches Of 0.6 Mtr Depth And 2.0 Mtr Wide Mtr In Normal Soil / Hard Soil 99 Repairing / Laying Of Ms Flat And Ms Rod In Deep Excavated Trench And Welding Of Ms Flat & Ms Rod With Mesh. 100 Repairing Of Earthing With Spikes Of Ms Rod 20Mm, 3 Mtr In Length As Per Rec Drawing 101 66-33 / 11 Kv Power Transformera ) Opening Of Transformer Tank Top Cover To Prevent Oil Leakage From Top ( If Required To Facilitate Maintenance Of Transformer After Removing The Required Accessories ) , , Draining / Re-Filling Of Required Oil, Change Of Gaskets Of Valves / Radiators / BuchholzS Relay Radiators Valves Of Power Transformer Of Capacity: 3.15 Mva To 20 Mva 102 B ) Replacement Of Silica Gel 103 C ) General Inspection By Through Inspection Of Each Individual Parts, Ratio Test By Applying Voltage On Hv Side And Measuring Lv Voltage On Various Tap Positions, Checking Of Buchholz Relay, Surge Relay Conservator, Sensors, Measurement Of 1R-Value Dialectic Strength Of Oil, Cleaning Of Power Transformer Etc 104 D ) Replacement Of Any One Of The Following I.E. Temperature Indicators, Gas Operated BuchholzS Relay, Oil Temperature Indicator, Winding Temperature Indicator Etc 105 E ) Preventing Of Leakage By Changing Main Gaskets After Removing The Old Gasket, Replacement Of Hv / Lv Busing & Bush Rod, Ring And Rubber Washers ( Complete Job To Prevent Leakages ) 106 F ) Cleaning Of Scale Deposited Over The Body And Radiators Of The Power Transformer With Thinner / Detergent And De-Rusting In Perfect Manner. ( Routine Work ) 107 G ) Cleaning Of Lv / Hv Bushings Of Power Transformer ( Routine Work ) 108 H ) Replacement Of Bus Bars Ofpower Transformer 109 I ) Replacement Of Lv / Hv Clamps Of Power Transformer 110 Oil Topping Of Power Transformer 10 Mva To 20 Mva 111 Oil Topping Of Power Transformer 4 Mva To 6.3 Mva 112 Oil Topping Of Power Transformer 3.15 Mva 113 Recording Of Ir Values Of Transformers 114 Installation, Testing And Commissing Of Power Transformer 66-33 / 11 Kv Installation Of Lv / Hv Bus Bars With Proper Care, Of Transformer For Any Leakagecommissioning Of Power Of Transformers By Applying Low Voltageapproximately Equal To Impedance Voltage On Hv Side And Short Circuiting The Lv Terminals, Energizing The Transformer By Applying Required Primary Voltage To It & Keeping The Transformer On No Load To Observe The Behaviour Of Transformer, Setting On 25% Of The Load On The Transformer For A Period Of At Test 6 Hours And Observation Of Oil Including Temperature, Increase The Transformer Is Fully Loaded And Topping Of Oil.A ) 20 Mva 115 B ) 10 Mva 116 C ) 6.3 Mva 117 D ) Upto 5 Mva 118 Checking And Tightening Of Jumpers, Droppers In 66 / 33 Kv Outdoor Yard 119 Replacement Of T / Pg Clamps 120 Replacement Of Disc Insulators Including Its Hardware. 121 66 / 33 Kv La & 11 Kv Stn. Type Lareplacement Of 66 Kv, 33 Kv & 11 Kv Lightening Arrestor Including Jumpering And Earth Connecting In All Respect. A ) 66 Kv La 122 B ) 33 Kv La 123 B ) 11 Kv La 124 Separate Pipe Earthing / G.I Rod Earthingas Per Rec Drawing 125 Replacement Of Pipe Earthing / Rod Earthing With New One 126 Installation, Testing And Commissioning, Replacement Of 66 Kv Isolators 127 Installation, Testing And Commissioning, Replacement Of 33 Kv Isolators 128 Replacement Of11 Kv Isolators 129 Repair & Renovationof 66 / 33 Kv And 11 Kv Isolators Including Setting Right Its Alignment For Proper Operation, Lubrication / Greasing Of Jaws, Bearings OperatingS Handle Etc ( Complete Job ) 130 Replacement Of Worn-Out / Heated Pad Clamp / Isolator Clamps Of 66 / 33 / 11 Kv Isolator By Way Of Dismantling. Drilling Of Holes On New And Fixing ( Complete Job ) 131 Repair & Renovationof Isolator Jaws 66 / 33 Kv And 11 Kv Isolators. ( Complete Job ) 132 Replacement Of Post Insulator / Tendon Pipes / Operating Box By Way Of Dimentalling, Necessary Fabrication Where Ever Required For Proper Operation Of 66 / 33 / 11 Kv Isolators. 133 66-33 Kv Ctsinstallation, Testing And Commissioning Of 66-33 Kv Cts ( Of All Ratios ) Complete Job 134 66-33 Kv Ctsrepairs & Renovation Of 66 / 33 Kv Cts By Way Of Replacing Shorting Strips, Connecting Rod, Transformer Oil, Damaged Insulator ( CtS Of All Ratios ) 135 Replacement Of 66 Kv Outdoor Type Ct Of Different Ratio And Dismantling Of Damaged Ct ( CtS Of All Ratios ) 136 Replacement Of 33 Kv Outdoor Type Ct Of Different Ratio And Dismantling Of Damaged Ct ( CtS Of All Ratios ) 137 Oil Topping Of 66 / 33 Kv Ct & Pt By Way Of Opening Of Top Cover And Refixing With New Gaskets If Necessary And Preventing Of Oil Leakages If Any. ( Complete Job ) 138 66-33 Kv Ptsinstallation, Testing And Commissioning Of 66-33 Kv Pts ( Complete Job ) 139 66 Kv Ptsreplacement Of 66 Kv Outdoor Type Pt And Dismantling Of Damaged Pt, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 140 33 Kv Ptsreplacement Of 66 Kv Outdoor Type Pt And Dismantling Of Damaged Pt, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure 141 66 Kv Post Insulatorreplacement Of 66 Kv Post Insulatorand Dismantling Of Damaged Pi, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 142 33 Kv Post Insulatorreplacement Of 33 Kv Post Insulatorand Dismantling Of Damaged Pi, Dragging To Installation / Loading Site, Lifting From Ground To Steel Structure. 143 Cleaning Of Porcelain Bushing, Tightening Ofpt / Ct Clamps, Derusting & Painting Of Body Of 66 / 33 Kv Pts & Cts 144 Tightening Of Nuts & Bolts, Replacement Of Oval Thread Bolts, Chipping By Way Of Welding To The Bolts After Tightening In A Single Bay 145 Painting With Mix Red Oxide Paint Two Coats Of Approved Make On Steel Works After Cleaning With Wire Brush / Sand Paper 146 Painting Of Steel Structure Erected In Outdoor Yard With Aluminium Paint Two Coats With Approved Brand Andfixture To Given An Even Surface 147 Battery Banka ) Repair & Maintenance Of Battery Set Including Maintaining Specific Gravity, Electrolyte Level, Cleaning, Checking, Tightening Of Battery Terminals In All Respects It Includes Measuring Voltage Of Each Battery. 148 B ) Tightening Of All Nut And Bolts, Replacement Of Damaged Battery Cells 149 C ) Installation, Testing And Commissioning Of Battery Bank ( Complete Job ) 150 Battery Chargerrepair / Renovation Battery Charger For Proper Functioning By Way Of Replacement Of Rectifier Unit, Ammeter, Voltmeter, Mcb, Cooling Fan, Led Indications, Buzzer Alarms For Ov / Uv Etc ( Complete Job ) 151 Repair And Maintenance Of Dc Board, Identification Of Fault In Respect Of Cableand Its Replacement, Replacement Of Damaged Mccb, Kit Kat, Bus Bar & Other Allied Job. 152 Repair And Maintenance Of Ac Board, Identification Of Fault In Respect Of Cableand Its Replacement, Replacement Of Damaged Mccb, Kit Kat, Bus Bar & Other Allied Job. 153 Installation, Testing And Commissioning Of Battery Charger ( Complete Job ) 154 Deweeding Of Vegetation In Outdoor Yardremoving Of Stone Metal, Deweeding Of Unwanted Vegetation, Spreading Of Stone Metal Collected Earlier For Removal Of Vegetation, Levelling The Area With Existing Stone Metal 155 Providing Of Additional Stone Metal And Its Carriage And Laying In Outdoor Yard, This Including Breaking Of Stones Complete Job. 156 Cleaning Of Control Room, Removing Dirt & Dust From The Panels, Walls, Cleaning Of Fixtures ( For One Bank ) 157 Painting Of Internal / External Walls And Roof By Approved Brand Of Oil Based Distemper 158 Painting Of Door And Window Panels Of Control Room By Approved Brand Of Paint 159 Repairs & Renovation Of 11 Kv Vcb, By Way Of Replacement Of A ) Grid-Spout Assembly 160 B ) Replacement Of Damaged Cts Of Different Ratio Testing The Ct With The Help Of Primary Injection Set Fixing In Pannel, Fixing The Secondary Connection After Assessing The Load ( Complete Job ) 161 C ) Thorough Checking Of Control Wiring Circuits, Replacement Of Damaged Wire If Any, Replacement Of Terminal Plates, Tripping Circuits, Close / Trip Switch, Ammeter Switch, Replacement Of Voltmeter & Ammeter . 162 D ) Replacement Of 11 Kv Damaged Pt 163 E ) Replacement Of Blown Fuses, Checking The Pt Terminal With Respect Of 11 Kv Bus Bar Complete Job. 164 F ) Replacement Of Trip / Close Coil 165 G ) Replacement Of Trivector Meter On 11 / 33 / 66 Kv Panels 166 Installation, Testing And Commissioning , Replacement Of Lt Cabele 167 11 Kv Power Cables / 33 Kv Power Cables / 66 Kv Power Cablesa ) Identification Of Damaged Portion Of Cable, Tracing Of Cable, Remove Cable From Trench, Carriage And Laying Of Cable ( Complete Job ) Including Cleaning Of Cable Trenches. 168 B ) Replacement Of Damaged Cable Of Sizes 169 Replacementof Termination Kits Of Different Sizes, Connecting The Cable With Panel And Outgoing Structures After Crimping Of Lugs Fixing With Nuts And Bolts, Checking Of Earth Point, Connecting The Earthing Point Of Cable With Existing Earthing System A ) 11 Kv Indoor Termination Kit ( 1-Phase / 3 Phase ) 170 B ) 11 Kv Outdoor Termination Kit ( 1-Phase / 3 Phase ) 171 C ) 33 Kv Indoor Termination Kit ( Single Phase ) 172 D ) 33 Kv Outdoor Termination Kit ( Three Phase ) 173 E ) 33 Kv Indoor Termination Kit ( Three Phase ) 174 F ) 33 Kv Outdoor Termination Kit ( Single Phase ) 175 G ) 66 Kv Indoor Termination Kit ( Single Phase ) 176 H ) 66 Kv Outdoor Termination Kit ( Single Phase ) 177 Improvement Of Earthing System In Control Room By Way Of Replacement Of Earthing Risers From Earthing Point To Panel / Checking Of All Welding Points / Re-Welding Of Lose Connection, Laying Of Fresh / Additional Earth-Mat Strip To Improve The Existing Earthing System ( Complete One Panel Set ) 178 Checking Of Ir Values 179 De-Watering Of Receiving Station To Avoid Water Logging. 180 Repairing Of Electrical Circuits For Improvement Of Control Room Immunination, Power Points Etc ( Complete Job ) 181 Installation, Testing, Commissiing For Replacement Of Aux. Transformer At Receiving Station 182 On Site Repairing Of Aux Transformer For Missing Phase, Lt Strip, Lt Bush Rod, Lt Bush Cup, Ht Bush Rod Etc ( Complete Job ) 183 Transport Charges For Carriage Of T&P, Men & Material On Urgent Basis During Power Breakdown And Restoration Of System. ( Auto Carrier ) Aditional 1Km @ 90 / Per Km 184 Replacement Of Out Door Yard Lights Including Wiring System And Fixing Oflamps On Fixtures. 185 Marking Of EquipmentS, Sign Boards By Way Of Painting / Fixing Of Pvc Plates For Demarcation Of Different Equipment To Avoid Mishandling. 186 Replacement / Repair / Fixing Of Ceiling Fans At Receiving Station. 187 Replacement / Repair / Fixing Of Cooling Fans On Radiators Of Power Transformer To Avoid Heating. 188 Flash In 66Kv, 33 Kv & 11 Kv Panels Due To Overloading Moisture, Cleaning Of Carbonized Panel By Petrol / Cotton Cloth, Replacement Of Damaged / Worn-Out Lugs, Post Insulator, Bakelite Sheet, Arcing Chamber Panel Heaters Etc. 189 Repair Of Plaster Of Thickness 12 Mm To 20 Mm In Patches Of Areas 2.5 Sqm Meters And Under Including Cutting The Patch In Proper Shape And Preparing And Plastering The Surface Of The Walls Complete Incl. Disposal Of Rubbish To The Dumping Ground Within 50 M Leada ) With Cement Mortar 1:4 ( 1 Cement : 4 Fine / Coarse Sand ) 190 Cutting Of Large Tree Branches Falling Over 66 / 33 Lines And Coming Into The Corridor To Avoid Damages / Faults / Conductor Snapping. 191 Cleaning Of Cable Duct, Removing Of Duct Covers And Placing Back After Cleaning The Duct Including Disposal Of Rubbish Up To 50 Mtr Lead 192 Replacing Sand Store Slabs In Roofing, Laid Incement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Including Necessary Repairs And Cement Painting With Same Mortar Complete, Including Disposal Of Rubbish To Dumping Ground Within 50 Meters Of Lead 193 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chow Khats, Holdfast Etc. Complete And Stacking With 50 Mtr Lead 194 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel T-Sections, Joints Mitred And Welded, Including Fixing Of Necessary But Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer ( Cc 1:3:6 ) 195 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Mtr 196 Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) 62 Mm Thick 197 Roof Top Treatment To Prevent Water Leakage Of Control Room 198 Repairing Of Receiving Station Mesh Fencing / Chain Link Mesh Fencing Height Upto 8Ft 199 Watering Of Earth Pits 200 Cleaning Of Acdc, Dbdc Board, Rtcc, Charger, Battery Bank, Solar Batteries, Other Alike Small Equipments ( Complete Job ) 201 Cleaning Of 66 / 33 Kv Crp Using Vacuum Cleaner From Inside With Proper Care, From Outside With Thinner / Varnish And Making 66 / 33 Kv Crp Vermic Proof. 202 Cleaning Of 11 Kv Panel Using Vacuum Cleaner From Inside With Proper Care, From Outside With Thinner / Varnish And Making It Vermic Proof To Avoid Rodent Faults. 203 Erection Of Channel Cross Arm Of Size 100X50x 6Mm , 10 Feet Long And Above Including Fixing Of Ms Flat Iron Clamps With Required Size Of Bolts Including Punching Of Bolts Complete 204 Erection Of Channel Cross Arm Of Size 100X50x 6Mm Up To 09 Feet Long Including Fixing Of Ms Flat Clamps With Required Size Of Bolts Including Punching Of Bolts Complete 205 Erection Of Angle Iron Braces Of Size 65X65x6 Mm, Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Typeabove Up To 14Longcomplete 206 Erection Of Angle Iron Braces Of Size 65X65x6 Mm Along With Belts Of Same Size , Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Type 6 And Above Upto 10Longcomplete 207 Erection Of Angle Iron Belts Of Size 50X50x 6 Mm Along With Belts Of Same Size , Fixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Cross Section Type Upto 10 Long 208 Erection Of Angle Ironof Size 65X65x6 Mmfixing With Double Clamp Of Ms Flat Including Punching Of Bolts Of Ist Level To Level 3Rd In Crossection Typeabove11 Long Complete For Guardnetting. 209 Flat Iron Ties 50X6 Mm Size 1 Feet Long Along With Fixing With Cross Arms 210 Erection Of 66 Kv Disc Insulator ( Polymer Type ) With Tension Fittings Including Punching Of Locking Pinscomplete 211 Erection Of 33 Kv Disc Insulator ( Polymer Type ) With Tension Fittings Including Punching Of Locking Pinscomplete 212 Erection Of 66 Kv Pin Insulator With Pins3 Nos On Top Of Cross Arm Including Fixing Of Ms Flat Ties To Rest It On , Punching Of Base Bolt / Locking Pin Complete 213 Erection Of 33 Kv Pin Insulator With Pins3 Nos On Top Of Cross Arm Including Fixing Of Ms Flat Ties To Rest It On , Punching Of Base Bolt / Locking Pin Complete 214 Erection Of Guy Rodincluding Digging Of Pit , Disposal Of Excavated Soil , Refilling Of Excavated Pits In Layers Of Stone Boulders And Fine Soil Including Fixing , Adjusting Properly Turn Buckle, Anchor Plate And Staining Screw Complete 215 Carriage At Site , Un-Bundling , Laying And Stringing Of Acsr Dog Conductor Including Making Of Small Bundles Of Conductor As Per Site Requirement, Cutting In Required Span Lengths Complete ( As Per Rec Standard ) 216 Erection Of Anti Climbing Devices At St Pole Along With Fixing / Cutting / Bending Of Barbed Wire, Fixing With Clamps 217 Erection Of Danger Plates 218 Route / Temp Path Clearance By Way Of Cleaning Bushes And Vegetation & Making Temp. Pathcutting & Filling For Carriage Of Line Material ( 400 Mx1mx0.2M ) = 80 Cum 219 Watch And Ward Of The Material And T&P Round The Clock I.E. 3 Shifts, Rate Of 1 Lab For 1 Shift 220 Route Clearance For Corridor Of 5 M 221 Installation, Testing And Commissioning Of 11Kv Panel Board With Vcb Incomer ( One No. ) 222 Installation, Testing And Commissioning Of 11Kv Panel Board With Vcb Outgoing ( One No. ) 223 Setting Of Stubs With Templates After Positioning And Leveling Of Templates Excluding Cost Of Foundations 224 Handling And Fabrication Of Material In Divisional Store, Fabrication Of Angle Iron Braces / Belts / Guard Netting Angles, Fencing Posts Etc From Angle Iron Of Sizes 225 Fabrication Of Guy Rods Complete Including Turn Buckle, Staining Screw, Anchor Plate, Thereading Of Guys And Staining Screw 226 Fabrication Of Channel Cross Arms Of Sorts From Ms Channel Of Sizes , Making Holes As Per Requirement, Punching Of Members And Numbering On Each Member, Grinding Of Sharp Edges And Uneven Surface Of Memebers And Painting Of Members With Red Oxide Paint. 227 Fabrication Of Ties, Clampsfrom Ms Flat ( Suitable For 9 Mts, 11Mts, 13Mts & 16 Mts Poles ) 228 Fabrication Of Earthing Plates , Cable Duct Coversfrom Ms Plate As Per Rec Drawings 229 Fabrication Of Earthing Spikes From Ms Tor Steel Of Sorts As Per Rec Drawings 230 Fabrication Of St Poles By Way Of Drilling Of Extra Holes 231 Fabrication Of Foundation Boltsfrom Ms Tor Steel Of Sorts Including Threading As Per Rec Drawings 232 Fabrication Of Earthing Pipe From Gi Pipe And Welding Of Earthing Plateas Per Rec Drawings 233 Fabrication Of Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures As Per Rec Drawings 234 Shifting Of Channel / Angle / Flat Iron At And Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly. 235 Shifting Of Channel / Angle / Flat Iron / Fabricated Material At And Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 236 Unloading Of Pcc Poles 9 / 8 Mts . 237 Unloading Of Pcc Poles 11 Mts . 238 Unloading Of Pcc Poles 13 Mts . 239 Dragging / Shifting Of Pcc / St Pole At And Average Istance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking 240 Shifting Of Old / New Acsr Conductor At And Average Distance Of 50Mtr For Unloading Site To Site Of Stacking And Stacked Properlyand Also For Making Space For Other Store Material And Its Stacking .. 241 Unloading Of 11Kv Vcb Pannels ( 1+3 ) 242 Unloading Of 11Kv Vcb Pannels ( 1+4 ) . 243 Unloading Of 11Kv Vcb Pannels ( 1+5 ) . 244 Unloading Of 11Kv Vcb Pannels Ok / Damaged ( 1No ) . 245 Unloading Ofac Board / Dc Board / Battery Bank / Battery Charger 246 Unloading Of 33 / 66 Kv Vcb / C&R Pannel . 247 Shifting / Draggingof 11 / 33 / 66Kv Panel At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking Also For Making Space For Other Store Material And Its Stacking . 248 Unloading Of Xlpe Cable 120 / 185 Mm² . 249 Unloading Of Xlpe Cable 240 / 300 Mm² . 250 Unloading Of Xlpe Cable 400 / 630 Mm² . 251 Shifting Of Xlpe Cable All Sizes At An Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly Also For Making Space For Other Store Material And Its Stacking ... 252 Unloading Of 66 / 33 / 11 Kv Cable Kits Of Different Sizes 253 Shifting Of 66 / 33 / 11 Cable Kits Of All Sizes At An Average Distance Of 50Mtr From Unloading Site To Site Of Stacking And Stacked Properly Also For Making Space For Other Store Material And Its Stacking ... 254 Unloading Of Guy / Gi Wire / Barbed Wire Including Carriage Towards Stacking Site And Stacked Porperly. 255 Unloading Of 11Kv New / Damaged Distributiontransformer. 256 Dragging Of 11Kv Transformer At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking 257 Unloading Oftransformer Oil Barrels. 258 Dragging Oftransformer Oil Old / New Barrel At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satacking Also For Making Space For Other Store Material And Its Stacking .. 259 Unloading Ofms Angle, Ms Channel, Ms Flate , Tar Steel 260 Unloading Of Hardware Items Such As Nuts And Bolts , Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe Etc . 261 Shifting Ofhardware Items Such As Nuts And Bolts , Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe Etc At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 262 Unloading Of 33 / 11 Kv Disc Insulators. 263 Unloading Of 33 Kv Disc Fittings 264 Shiftingof 33 / 11Kv Disc Insulator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satackingalso For Making Space For Other Store Material And Its Stacking .. . 265 Unloading Of 33 / 11 Kv Pin Insulators / Guy Insulator / G.I Pin. 266 Shiftingof 33 / 11Kv Pin Insulator / Guy / G.I Pinsat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking. 267 Unloading Of Cement. 268 Shiftingofcement / Cement Block At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking ... 269 Unloading Of 33 Kv Ct / Ptunit . 270 Shifting Of 33 Kv Ct / Pt At An Average Distance Of 50Mtr For Making Space For Other Store Material And Its Stacking . 271 Unloading Of 11 Kv Ct / Ptunit Includingcarriage Towards Stacking Site And Stacked Porperly. 272 Shiftingof 11 Kv Ct / Ptat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 273 Unloading Of 33 Kv Isolators. 274 Shiftingof 33Kv Issolatorsat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Its Satackingand Also For Making Space For Other Store Material And Its Stacking . . 275 Unloading Of 33 / 66 Kv Las. 276 Shiftingof 33 / 66Kv Lasat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking . 277 Unloading Of 11 Kv Las / Go / Hg / Issolator . 278 Shiftingof 11 Kv Las / Go / Hg / Issolator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 279 Unloading Of Pvc Cable / Control Cable Of Different Sizeincludingcarriage Towards Stacking Site And Stacked Porperly. 280 Unloading Of Al Paint / Red Oxide Paint / Black Paintincludingcarriage Towards Stacking Site And Stacked Porperly. 281 Unloading Of 66Kvct / Pt / Isolator . 282 Shiftingof 66 Kv Ct / Pt / Isolator At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 283 Unloading Of T&P Items Like Drilling Machine, Chainpully , Pully Lifting Machine , Hand Drill Machine, Al Ladder, Welding Set, Tool Kit, Crimping Tooletc 284 Dismantling Of Old 11Kv Isolator Including Allied Equipments 285 Installation Of 11Kv Isolators 286 Shiftingof T&P / Testing / Safetyequipments At An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking .. 287 Unloading Of Filter Plant Heavy Duty 288 Shiftingof Filter Plantat An Average Distance Upto 50 Mtr For Stacking To Accesible Place For Loading / Unloading Purpose And Also For Making Space For Other Store Material And Its Stacking . 289 Loading Of Pcc Poles 9 / 8 Mtr 290 Loading Of Pcc Poles 11 Mtr 291 Loading Of Pcc Poles 13 Mtr 292 Loading Of Cement 293 Loading Of 11 Kv Vcb 1+3 Pannels 294 Loading Of 11 Kv Vcb 1+4 Pannels 295 Loading Of 11 Kv Vcb 1+5 Pannels 296 Loading Of 11 Kv Vcb 1 Pannel Ok / Damage 297 Loading Of Ac Board / Dc Board / Battery Charger / Battery Bank 298 Loading Of 33Kv Vcb 299 Loading Of 33Kv C&R Pannels 300 Loading Of Xlpe Cable 120 / 185 Mm² 301 Loading Of Xlpe Cable 240 / 300Mm² 302 Loading Of Xlpe Cable 400 / 630 Mm² 303 Loading Of Cable Kits Of Different Sizes 304 Loading Of Guy / Gi Wire / Barber Wire 305 Loading Of 11 Kv Distributiontransformer 306 Loading Of Transformer Oil Barrels 307 Loading Of Ms Angle Iron Braces, Ms Channel Cross Arms, Guy Rod, Earthing Spikes, Ms Flate 308 Loading Of Hardware Items Such As Nuts And Bolts, Clamps Of Sorts, Washers, Welding Rods, Old Sarees, Chain Link Mesh, Pipe 309 Loading Of 33 / 11Kv Disc Insulator 310 Loading Of 33 Kv Disc Fitting 311 Loading Of 33 / 11 Kv Pin Insulator / Guy Insulator / G.I Pin 312 Loading Of 33 Kv Isolator 313 Loading Of 33 Kv La 314 Loading Of 11Kv Isolators 315 Loading Of Pvc Cable / Control Cable Of Different Size Includingcarriage From Stacked Site. 316 Loading Ofal Paint / Red Oxide Paint / Black Paint 317 Loading Of66kvct / Pt / Isolator 318 Loading Of66kvc&R Pannel 319 Loading Of66kv Vcb Breaker Sf6 320 Loading Of66kv La 321 Loading Offilter Plant Heavy Duty 322 Carriageof Fabrication Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures Etc Towards Stacking Site And Stacked Properly 323 Loading Offabrication Column Structures, Beam Structure, Isolator Structures, La , Ct, Pt And Pi Structures Etcincludingcarriage From Stacked Site. 324 Loading Of 33 Kv Ct / Pt Units 325 Loading Of 11 Kv Ct / Pt Units 326 Loading Of T&P Items Like Drilling Machine, Chainpully , Pully Lifting Machine , Hand Drill Machine, Al Ladder, Welding Set, Tool Kit, Crimping Tooletc Units 327 Loading Of Testing Equipments Like Meggar, Earth Resitivitytester , Oil Testing Machine, Search Light, Turn Ratio Meter , Multimeter Etc Units 328 Loading Of Safetyequipments Like Safety Belts, Safety Shoes, Fire Extinguisher, Hand Gloves, Yard Lights , Led Bulbs , Rubber Mat , Etcunits 329 Shifting Of Allied Materials For Making Space For Porper Stacking Of Material 330 Carriageof Fabrication Material From Fabrication Site Towardsstacking Site And Proper Stacking Of Material. 331 Repair Of Store Shed By Way Of Replacement Of Damaged Cgi Sheets, Repair Of Cgi Sheets By Way Of Welding, Replacememt Of Hooks, Nuts And Bolts, Tightening Of Nuts Bolts And Hooks And Welding . 332 Collection Andcarriage Of T&P Items To Working Site And Back Crriage Of T&P After Job 333 Replacement Of Damaged Glass Panes 334 Replacement Of Damaged 66 / 33Kv PiS 335 Checking / Measuring / Inspection / Meggering Ofxlpe Cable / Control Cable By Way Of Unreal And After Work Agian Rereelingon Drum 336 Checking / Measuring / Inspection Ofacsr Conductorby Way Of Unreal And After Work Agian Re-Reelingon Drum 337 Complete Testing / Inspection Of Pannels Including Relay Testing , Interconnection, Charging Polarity Etc During Issue / Receipt / Verification. 338 Prototype Erection Of Gantry / Beam / Ct / Pt / Isolator Sturcture 339 Charges For Providing Highly Skilled Electrician / Fitter / Welder / Mason / Painter 340 Charges For Providingskilled Electrician / Fitter / Welder / Mason / Painter 341 Charges For Providingunskilled Labour
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Jammu And Kashmir View Result →
49.
Educational and Research Institute #9113446 Technical Bid
Tender For Supply and Installation of Lab for Health Care for IX-XII (as per CBSE /SSC Requirement)- 1 Arduino Uno Made In Italy ATmega328P - 8 bit AVR familyMicrocontroller, equivalent or better. Operating Voltage: 5V Digital I/O Pins: 14 (of which 6provide PWM output) PWM Digital I/O Pins : 6 Accessories : Case shellenclosure, compatible USB cable (length - 6 inch or more) 2 Arduino Nano Made In Italy ATmega328P - 8 bit AVR familyMicrocontroller, equivalent or better. ConsumableOperating Voltage: 5VDigital I/O Pins : 14 (of which 6provide PWM output)Analog Input Pins : 8Accessories : Compatible USB cable ( length -6 inch or more) 3 Arduino Mega Made In Italy AT mega 2560P - 8 bit AVRfamily microcontroller, equivalent or better. Operating Voltage: 5V Digital I/O Pins : 54 (of which 6provide PWM output) Analog Input Pins: 16 Accessories: Case shell enclosure, Compatible USBcable ( length -6 inch or more) 4 Raspberry Pi 4 Model B RASPBERRY PI 4 MODEL B,equivalent or betterBroadcom 2711, 64-bit quad-core Cortex-A72 processor, 4GB RAMTrue Gigabit Ethernet port, 2 x USB 3.0 “Super-Speed” ports802.11b/g/n/ac wireless LAN (2.5 GHz & 5GHz) Bluetooth 5.0Dual micro-HDMI ports, 4K UHD video H.265 decode (4kp60)H.264 decode (1080p60)OpenGL ES 1.1, 2.0, 3.0 graphics PoE capable 5V3A USB-C power supply required 5 Breadboards & Mini Breadboard Solderless 400 pin breadboard 6 Breadboards & Mini Breadboard Solderless 800 pin breadboard 7 Breadboards & Mini Breadboard Self-Adhesive Proto Shield 8 General Purpose solderable BoardFR2 A Grade Material (140 x 90 mm) 9 General Purpose solderable BoardFR2 A Grade Material (80 x 55mm) 10 Berg StripsFemale Berg Strip, 2.54mm pitch, 40 pin single row, breakable pin 11 Berg StripsMale Berg Strip, 2.54mm pitch, 40 pin single row, breakable pin 12 16x2 LCD displayDot matrix LCD display. 16 characters X 2 lines. I2C 13 USB CablesUSB Cable Set (A to B, 12 inch or more) 14 USB CablesUSB Cable Set (Mini, 12 inches or more) 15 Battery9-12V 2000 to 2500 mAhrechargeable battery with 2 chargers. Equivalent or better 16 Resistor KitOne kit contains - 30 carbon film resistors of 20 different resistance values each assorted, packaged together and labelled.Wattage: 0.125W to 1WValues: 0O, 1.5O, 4.7O, 10O,47O, 100O, 220O, 330O, 470O,680O, 1kO, 2.2kO, 3.3kO,4.7kO, 10kO, 22kO, 47kO,100kO, 330kO, 1MO 17 Capacitor KitOne kit contains - 20 electrolytic capacitors of 10 different capacitance valueseach.Assorted kit packagedtogether and labelled.Values: 10pF, 22pF, 100pF, 1nF, 10nF, 100nF, 1µF, 10µF,100µF, 1000µF 18 Linear Voltage Regulator7805, 7812,7809 19 Water PumpModuleDC12V 3W Submersible WaterPump 20 PiezoelectricPlate Normal Copper based 4 cmDiameter approx. 21 8*8 LED Matrix Module Max7219 Dot LED Matrix Module. MCU Control LED Display Module 22 Bluetooth moduleHC 05 Bluetooth moduleVoltage Rating: 5 V 23 7 Segment Led DisplayLED 4-Digit Display ModuleVoltage Rating: 2.4V to 5.5V4-Pin interface:Vcc, Gnd, Data, Clock 24 GSM Sim900 GPRS Transfer Board Micro Sim Gsm Core TTL PortModule for Arduino 25 GPS GY-NEO6MV2 new GPSmodule 26 Laser DiodeEmitter 650 nm 5V Mini Laser DotDiode Module 27 LDR Module 5mm/12mm, PhotosensitiveLDR Light Sensor Module 28 Keypad Universal 16 Key SwitchKeypad 29 JoyStick 2-axis joystick with pushbutton function 30 Active BuzzerSmall 5 volt 31 Active BuzzerBig 5 volt 32 Motor driverModule L293D, 4-Channel driver module 33 Sound PlaybackModule ISD1820 voice recordingmodule or equivalent 34 DC Plastic Gear motor withWheel 12V, 150RPM, Side Shaft BO (Battery operation) Motor 35 Node MCUESP 8266I2C, 1 wire, plug and play 36 WeMos D1 R2WeMos D1 R2 with WiFi ESP8266Operating Voltage: 5V 37 Vibrating MotorWeight: 10 GramsOperating Voltage: 1.5 to 3V 38 AlligatorConnectors Multi-Colour AlligatorConnectors - 12 inch 39 Battery clipswith DC Jack 9-volt battery clips with DCJack 40 Hook-up Wires Red & Black set 100 Meterseach 41 Jumper CableMale-Male 42 Jumper CableMale-Female 43 Jumper CableFemale-Female 44 RGB LEDs Regular 5mm 3-5 volt Range 45 LEDs (Red) Regular 5mm 3-5 volt Range 46 LEDs (Green) Regular 5mm 3-5 volt Range 47 LEDs (Blue) Regular 5mm 3-5 volt Range 48 LEDs (Yellow) Regular 5mm 3-5 volt Range 49 LEDs (White) Regular 5mm 3-5 volt Range 50 Timer IC - LM 555LM 555 Timer IC.Voltage range - 4.5V to 16V 51 Atmega16u28 bit microcontroller Individual IC (DIP).Voltage range: 2.7V to 5.5V.Operational Range: -40°C to+80°C 52 Diodes and Transistors KitOne Kit Contains - 25 Assorted Basic Diodes of 4 differenttypes each.Types: NPN Transistor - 2N3904, BC547 PNP Transistor- 2N3906, BC557 Silicon Diode- 1N4148, Power Diode - 1N4004/4001.Equivalent or better.Wattage: 1W, Current rating:1AAssorted kit packagedtogether and labelled. 53 Button Switch SetOne Kit Contains - 100 buttonsof different types.Types: Push, toggle, rotary,selector and slide switch.Assorted kit packagedtogether and labelled. 54 Capacitative touch ModuleMPR 121 with I2C.Voltage Range:2.5V to 3.6V DC. 55 Capacitative Touch Switch ModuleDigital Capacitive touch switchmodule -TTP223BVoltage Range: 2V to 5V DC. 56 IR Proximity Sensors, Obstacle avoider sensor moduleLM393Detection distance:2 - 30 cmDetection angle: 30 - 40° 57 Triple Axis Magnetometer3-Axis Magneto resistiveSensorsI2C Digital InterfaceIntegrated 12-bit ADCRange of -8 to +8 Gauss160 Hz Maximum o/p rate 58 Humidity SensorOperating range:20 – 95 % RHTemperature: 0 - 60 CelsiusPower supply:1.5V AC (Max sine)Operating frequency:500Hz - 2kHz 59 MQ SeriesMQ - 2 Smoke DetectionMQ-3 Alcohol - Ethanol SensorMQ-4 Methane Natural GasSensorMQ-5 Methane Liquefied GasSensorMQ-6 Liquefied Petroleum GasSensorMQ-7 High Sensitivity CO Carbon Monoxide SensorDetectorMQ-8 Hydrogen Gas SensorMQ-135 Air Quality Sensor 60 MQ SeriesMQ-3 Alcohol - Ethanol Sensor 61 MQ SeriesMQ-4 Methane Natural Gas 62 MQ SeriesMQ-5 Methane Liquefied GasSensor 63 MQ SeriesMQ-6 Liquefied Petroleum GasSensor 64 MQ SeriesMQ-7 High Sensitivity CO Carbon Monoxide SensorDetector 65 MQ SeriesMQ-8 Hydrogen Gas Sensor 66 MQ SeriesMQ-135 Air Quality Sensor 67 IR transmitter/TSOP 1738ReceiverSwitching rate: 38 KHzVoltage Rating: 5V 68 Ultrasonic Sensor Module HC-SR-04 orCompatibleWorking Voltage - DC 5VWorking current - 15 mAWorking Frequency - 40 HzRange - 1 cm to 4 mEffectual Angle - <15°Measuring Angle - 30°Resolution - 0.3 cm 69 Triple Axis accelerometer-3-axis sensingSmall, low profile package4 mm × 4 mm × 1.45 mmLFCSPLow Power: 350 µA (typical)Single-supply operation: 1.8 Vto 3.6 VTemperature stability 70 PIR Motion Detector ModuleHigh digital pulse whenmotion detectedLow digital pulse when idle/no motion detectedSensitivity range (up to 6 m)Power supply: 5V – 12V 71 Pulse Rate Heart Sensor Pulse Rate Sensor Finger Based (finger or earlobe)Working voltage 3-5V 72 Relay Module 5V 10A - 2 Channel Relay Module. Compatible with Arduino. 73 Relay Module 5V 10A - 1 Channel Relay Module. Compatible withArduino. 74 Big Sound microphone module Large Electret capsule sound module 75 Soil Moisture Sensor moduleFC-28 with LM293 comparatorOperating Voltage: 3.3V to 5V. 76 Touch Sensor Capacitive Touch SensorModule. TTP22X series. Voltage Range: 2.4V to 5.5V 77 Metal Touch Sensor Module KY-036 or equivalent metal touch sensor module 78 Rain Drop Sensor Rain Sensitive, Rain DropDetection Sensor Module. Voltage Range: 3.3V to 5.5V. 79 Flex Sensor Flex Sensor. Size - 2.2 Inches 80 Temperature Sensor LM35 Full range temperature sensor. Voltage Range: 4V to 30V. Error: ±0.5°C 81 Temperature and humidity sensor moduleDHT 11Voltage Range: 3V to 5V 82 Force Pressure Sensor Force sensitive resistor with a square, 1.75x1.5 sensing area 83 ColourRecognition Sensor TCS3200 Colour Recognition Sensor 84 Water Flow Sensor Arduino Compatible Water flow sensor. 5V DC Input. 85 Sound Sensor Sound Sensor Module, Microphones module 86 IR Sensors Array module for Line Following8 IR Sensors Array module forLine FollowingOperating Voltage: 5V 87 Power Bank 10000 mAh 5-volt Power Bank 88 RFID Reader –TagsCurrent :13-26mA / DC 3.3VIdle Current :10-13mASleep Current<80uAPeak Current<30mAOperating Frequency:13.56MHz<30mARead range between 20 cm to 1 m 89 RF Modules Tx & Rx 315 MHz ASKFrequency Range: 433.92/315MHzSupply Voltage: 3 – 6 VOutput: 4 – 16 DbmLow power consumptionEasy application 90 Stepper motor with Driver board 28BYJ-48 ULN2003 5V StepperMotor + ULN2003 Driver Board 91 DC motor 12V DC Gear 150 RPM 92 Servo motorsPosition Servo Angle basedMetal Gear 93 Servo motorssmall Servo Metal Gear, 1.8Kg-cm(4.8volt), 2.2 Kg-cm(6v) 94 Servo motorsContinuous Metal Gear Servo360, 9.4 kg-cm(4.8volt) 95 Servo motorsSmall Servo Plastic Gear, Voltage – 5v 96 150 RPM BO(Battery operated)DC Motor 150 RPM BO Motor 97 L298P MotorDriver L298P Motor Driver Shield orrelative Driver Shield 98 Servo MotorTester CCPM 3 channel Servo Tester 99 Robotics DIY Kit Robotics DIY kit with programmable intelligentbrain/brick. 100 Mechanical (Modular)Construction kit Metal/plastic mechanical construction kit compatiblewith electronic equipment. 101 Drone KitEducational PurposeAerospace KitAutomobile KitBio-Medical KitAgri-Tech KitWater/Sanitation KitBio Tech KitOther Potential STEMApplication Kit 102 Educational Purpose 103 Aerospace Kit 104 Automobile Kit 105 Bio-Medical Kit 106 Agri-Tech Kit 107 Water/ 108 Sanitation Kit 109 Bio Tech Kit 110 Other Potential STEMApplication Kit 111 3in1 3D Printing Kit and tools 3D Printing + CNC Cutting + Laser Engraving MachinePrinter Type:FDM (Fused Deposition Modelling),Molding Technology: FDM fused deposition moldingMolding Size: 200x200x200mmFile Format: STL, OBJ, AMFSupporting Material: 1.75mm diameter PLA, ABS, TPU, PVANozzle Diameter: Standard 0.4 mm, can be in 0.6 mm,0.8 mm,1.0mm,1.2 mmHot Bed Temperature: =100°C CNC CuttingWorking Size: 200x200mmSupport Materials: wood, paper, PCB, plastic, etcFile Format: JPG, JPEGSpindle Speed: 4800 rpm maxStandard Cutter Size: Tungsten Alloy Milling CutterLaser EngravingWorking Size: 200x200mmSupport Materials: wood, paper, plastic, leather, etcFile Format: JPG, JPEGLaser Power: less than 0.5wQuality Anti-bacterial/fungal Cover.Repair Kit - with sparesprings, screws, keys, tweezers, etc. 112 Dedicated UPS/Power back up Dedicated UPS/Power Back up with 2-hour battery backup. 113 Filament for 3D printer Compatible 1000 Grams Filament in 5 different coloursWhite PLA -8Marble PLA-2Wood PLA - 2Glow in darkPLA on- 2Pink – 2Blue – 2Orange – 4Grey – 2 Black 2Red -2Green 2 114 Filament Storage Box Compatible Filament storage box 115 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping materialCardboard 116 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material Foam core boards 117 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material 20m spool of thick stringsvarious colour 118 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material Rubber band 119 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material Popsicle sticks 120 Set of Arts & Crafts Accessories – e.g.- stationary items and basic prototyping material Wood glue – 500 ml 121 Hacksaw Frame Size: 12 inchesMaterial – flat steel 122 Hacksaw blades Size: 12 inchesHigh carbon steel (HCS) 123 Mini Hacksaw Frame Size: 6 inchesFlat steel 124 Mini Hacksaw blades Size: 6 inchesHigh carbon steel (HCS) 125 Pliers: 4.5-inch size External Straight Nose Circlip Plier 126 Pliers: 4.5-inch size External Straight Long Nose Plier 127 Pliers: 4.5-inch size External Straight Combination Mini Plier 128 Pliers: 4.5-inch size External Straight Wire stripping pliers 129 Pliers: 4.5-inch size External Straight Bent nose plier 130 Pliers: 4.5-inch size External Straight Needle nose plier 131 Tweezer Set 6 Pc Non-Magnetic Tweezer SetSize - 6 inches 132 Ball Peen Hammer Ball Peen Hammer Weight - 0.75kg 133 Steel Shaft Claw Hammer Claw Hammer Steel Shaft Weight - 0.75kg 134 C-Clamp Metal Clamp: 3-inch size 135 Flexible Extension Shaft 150 mm length, 10mm chuck size 136 Allen Key Set 10 Piece Ring Imperial Allen Hex key 137 Drill Machine Set Drill Machine with accessories Hammer/Screw and clockwise/anticlockwise modes.Power: 500WChuck capacity - 1 to 10 mmDrill Bits Complete set Masonry –4, 5, 6, 8, 10 mm. Metal- 2, 3, 4, 5, 6 mm.Wood – 4, 5, 6, 8 mmSpirit level – Horizontal, vertical , slantingAdjustable knife and Wrench 138 Drilling Workstation Drill Press, Drill Holder and Rotary Tool, Compatible with Drillingmachine provided 139 Spanner Set 12-piece combination Spanner SetRange - 4 mm to 30 mm 140 Vice Normal Table top vice 141 Precision Screw Driver Set 6 Piece Precision Screw Driver SetTypes: PH0, PH1, Flat head - 1.4mm, 2mm, 2.4mm, 3mm 142 Wrench Adjustable UniversalWrench 143 Wire Strippers Wire Stripper Cutter PlierWith Spring -26x6x20 cm (LxWxH) 144 Screwdriver set 40 pc Multi-purpose screwdriver set 145 RotaryMultitool Set Rotary multitool with all cutting, grinding, polishing, engraving and drill bits.109-in-1 woodcarving drilling grinding drill tuner• Voltage:220-240V~50/60Hz• Input power:130W• No-load speed:10000-35000rpm• Collet size:3.2mm/2.3mm• Variable speed control• With 1pcs flexible shaft• With 109pcs accessories• With 1set extra carbon brushes 146 Air Blower 500 W or more. Variable speed blower 147 Drill Bit Set High Quality 13 Pcs HSS Drill Bits Set for Wood, Iron, Aluminium, Plastic etc. 148 File set 6 pc file setWorking length - 6 inch (different type) 149 Mini File set 6 pc mini file set Working length - 3 inch (different type) 150 Flexible Cutting Mat A3 Size with Marked Pattern and Grids (18 X 12) 151 Plastic Storage Drawer/Organiser Number of Drawers: 60 or equivalentDrawer size (l*w*d) (inch): 2*2*5 152 Pegboard Pegboard System to mount tools on wall with attachments (hooks etc.)Size: 3ft*2ft 153 Hot glue gun Works with standard 0.5- inch glue sticks.100Watts (220-240w)Temperature - 230 to 280 degree Celsius. 154 Digital Oscilloscope RIGOL or similar No genericMinimum Bandwidth: 50 Mhz.Minimum number of channels: 2 channels. Sample Rate: 1Gsa/s With inbuilt waveformFunction generator. 155 Soldering KitVariable Wattage of Soldering Iron: 15-30watts/230 voltsSoldering Iron Temperature Range: 280°C to 450°CDe-Soldering Pump, Soldering Flux (Paste) 100 grams,DE-soldering Copper Braid (Solder Wick) -1.5m*2mmCompatible Soldering Tip- Bevel, Chisel, Conical - 5 each per kit.Soldering Wire: 20/22 AWG soldering Wire with rosin core flux (100 Grams) 156 Adapters DC power Adapter with5V, 2A 157 Adapters DC power Adapter with12V, 2A 158 Electric Screw Driver Set (Cordless) Multipurpose Electric screwdriver set.Accessories - Compatible bitsMode - Wireless Battery - Li-ion 3.6V orequivalent with charging dockTorque hard : 5 NMTorque Soft : 2.5 Nm 159 Dual Temperature Heat Gun 1800 W Dual Temperature Heat Gun 160 Soldering Helping hand Specifications: Adjustable crocodile holding clamps/clip. Soldering iron holder. LED light.Magnifying lens. 161 Projector Type: No Optical Zoom / Focus (Manual)Focal Length:16.70 mmF-number:1.44Zoom:1.44 - 1.95 (Wide to Tele) RatioThrow Ratio Range:1.00 – 1.35 (Digital Zoom)3LCD technology for equal white & colour light outputNative XGA resolution and 4:3 performanceLong lamp life up to 12,000 hours*2 in ECO modeEasy setup and positioning flexibilityHDMI connectivity 162 Laptop • 12th Generation Intel® Core™ i7 processor• Windows 11 Home • 39.6 cm (15.6) diagonal, FHD (1920 x 1080), 144 Hz, 9 ms response time• NVIDIA® GeForce RTX™ 3050 Laptop GPU (4 GB GDDR6 dedicated)• 1 TB PCIe® Gen4 NVMe™ TLC M.2 SSD• 16 GB DDR4-3200 MHz RAM (2 x 8 GB)• Weighs: 2.29 kg 163 DesktopSpecificationValueProcessor Make IntelProcessor Generation i7 or higherNumber of Cores per Processor 12 or higherProcessor Base Frequency (GHz) 2.5 or higherCache (MB) 12 or higherGraphic card capacity Dedicated 2 GB or higherOperating System (Factory Pre- Loaded) Windows 11OS Certification Microsoft windowsType of RAM DDR5RAM Size (GB) 16 or higherRAM Speed (MHz) 4800 Mhz or higherRAM Expandability up to (using spare DIMM Slots in GB) 128 or higherType of Drives used to populate the Internal Bays SSDCapacity of each HDD (TB) 1 TB or higherWireless Connectivity Yes (inbuilt)Type of Wireless Connectivity Wi-Fi 802.11acNumber of Ethernet Ports 1Type of Ethernet Ports 10/100/1000 on board Integrated Gigabit PortLED Backlit Monitor Size (INCHES) 23.8 or higherMonitor Resolution (PIXELS) 4096×2160On Site OEM Warranty (Year) 5 or higherPort Connectivity DP port -1, HDMI -1, Audio out Port with microphone support, PCIe slot -2, USB port – minimum 4 (out of this minimum 2 USB 3.1), USB port – 2 on front, Type C port -1, M2 PCIeslot – 1Keyboard Wired Keyboard from the same OEM as Desktop with embossed OEM LogoMouse Wired Mouse from the same OEM as Desktop with embossed OEM LogoPower Supply 90% Efficient Power SupplyCompliance RoHS, Energy Star, EPEAT Gold Registered, TCO Certified 164 Return measuringTape Return measuring tape5Mx19mm 165 Stainless Steel Rule Stainless Steel 12” / 150mm Rule 166 Digital VernierCalliper 150 mm / 6” DigitalVernier Calliper 167 Spirit Level 12” Spirit Level 168 Digital Pen electricTester Voltage tester 169 Digital Multi MeterClam MeterDigital Multi Meter Voltage Current Resistance-7 functions + 19 ranges to cover DCvoltage 200mV to 1kV,AC voltage 200 V - 750 V,DC current 200 µA - 10 AResistance 200 -2 M Ohm and Transistor & diodetest. 170 DIY Paper Microscope DIY Paper microscope. Magnification range -100x to 2000x 171 TelescopeAll glass opticalcomponentsAltazimuth mount suitable for terrestrial andastronomical useminimum 700 mm focallength 172 Sewing KitSemi-Automatic SewingmachineStraight stitchConsumables - 2 set ofassorted needles and 10- colour spool set. 173 Glue Sticks 11 mm x 200mm Hot Melt Glue Stick 174 Nuts and Bolts and screw Specs - M4X12MM M4X20MM M5X16MMM5X25MM M6X20MM 175 Cable TieSmall Cable Tie Pack -Pack of 100 176 Cable TieMedium Cable Tie Pack - Pack of 100 177 Cable TieBig Cable Tie Pack - Packof 100 178 Sand Paper Grit Values - 80, 100,120, 200, 300.5 Nos of each 179 Power Strip Adaptors Standard Quality Extension with 5Amp safety fuse.5 or more sockets in each extension.5-meter length of each extension. 180 Bulb Holders Regular Hanging Bulb holder 181 Two Pin Plug Regular Two Pin Plug 182 Electric Wires 1.5 Sq mm wire spool copper 183 USB TO DCjack cable USB to DC jack cable for Battery bank 184 First-Aid Kit Standard Medical First Aid kit in portable container. 185 Fire extinguisher(handy units) Powder Type Fire Extinguisher 2KG 186 Safety goggles (with/ withoutLED torch) Polycarbonate Safety gogglesClear lens with no tintCover half upper face with adjustable strap 187 LED Bulb 9W 188 Laser safety glasses Optical Density 6 Bosch Laser Glasses 189 Safety Gloves Pairs Latex Coating Gloves (Medium Size) 190 Anti-static safe discharge wrist band Current limiting register 1 m Ohm +/- 5 %Electrostatic discharge time -<0.1 second 191 Safety Mask Filtering efficiency ranging 80 percent when tested against 0.3-micron sodiumchloride particle 192 Safety shoes • Lining: Moisture wicking breathable fabric lining• Steel Toe: Can withstand an impact of over 200 J• Sole: Double density directly injected PU sole. Care Instructions : Clean with Damp Cloth, Black Polish can be used• Oil and acid resistant, anti-static• Grey Spacer Lining ; Antistatic ; Lace-up model with D rings 193 Safety apron• Safety Uniform• Cotton• Industrial• All sizes• Color- As per requirement• Pattern- Plain 194 Safety Halmet • Safety Helmet• Colour ?Yellow• Material ?High Density Polyethylene (HDPE)• Specification Met ?Isi certified• Closure Type ?Ratchet• Department ?Unisex-Adult• Weight - 300 g approx.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
50.
Housing Urban and Rular Development #8979082 Technical Bid
Tender For Electrical Work - &P 2 Fire Fighting Work Fire Pumps And Accessories: Supplying, Installation, Testingand Commissioningof Electric Driven Main Fire Pump Suitablefor Automatic Operationandconsistingoffollowing, Completeinall Respects, As Required :A ) Horizontal Type, Multistage, Centrifugal, Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.C ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.D ) M.S. Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. E ) Suitablecementconcretefoundationdulyplastered With Anti Vibration Pads. F ) 2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 3 Supplying, Installation, Testingandcommissioningof Diesel Engine Driven Main Fire Pump Suitable For Automatic Operation And Consisting Of Following, Complete In All Respects, As Required : ( Diesel Driven Pump ) A ) Horizontal Type, Multistage, Centrifugal Pump Of Cast Of Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitablehp, 1500Rpmwatercooledwithradiator, Diesel Engine Conforming To Relevant Is Standard Completewithautostartingmechanism, 12 / 24Volts Electricstartingequipment, Dieseltank, Exhaustpipe Extended Upto 10 M Outside Pump House Duly Insulated With 50 Mm Thick Glass Wool With 1.0 Mm Thick Aluminium Sheet Cladding, Residential Silencer, Instruments And Protection As Per Standard Specification, Stop Solenoid For Auto Stop In The Event Of Fault With Audio Indications, Painted With Post Office Red Colour Etc. As Required. C ) M.S Fabricated, Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. D ) Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 4 Supplying, Installation, Testingandcommissioningof Electricdrivenpressurisationpumpsuitablefor Automaticoperationandconsistingoffollowing, Complete In All Respects, As Required : ( Jockey Pump ) A ) .Horizontaltype, Multistage, Centrifugalpumpofcast Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is : 1520. B ) .Suitablehpsquirellcageinductionmotortefctype Suitableforoperationon415volts, 3Phase50hz Ac Supply With Ip 55 Class Of Protection For Enclosure, Horizontalfootmountedtypewithclass-FInsulation, Conforming To Is : 325. C ) .M.S.Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required.D ) .Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.180 Lpm At 70 M Head 5 Control Panels: Fabrication, Supply, Insallation Testing & Commissioning Of Electrical Control Panel Of Cubical Construction, Floor Mounted Type, Fabricated Out Of 2Mm Thick Crca Sheet, Compartmentalisedwithhingedlockabledoors, Dustandverminproof, Powdercoatedofapproved Shade After 7 Tank Treatment Process, Cable Alley, Inter-Connection With Suitable Sizecopperconductor Cable / Solidcopper Strip, Havingswitchgears And Accessories, Mountings And Internal Wiring, Earth Terminals, Numbering Etc. Complete In All Respect, Suitableformainfirepump, Pressurisationpump& Dieselpumpsetcompleteaspercpwdspecification Withfollowingincomingandoutgoings, Suitablefor Operationon415v, 3Phase, 50Hzacsupplywith Enclosure Protection Class Ip 42 As Required :Incomings:A ) 630A, 50Ka4 Pole Mccb, Ics=100% Icu Rating Digital Voltmeter 0-500V With Selector Switch Ammeter ( 0-630 A ) With Selector Swtich & Cts Etc.B ) Ledtyperybphaseindicatinglamps, On, Off, Trip Indicating Lampsset Of Copperbus Bar 800Ampsoutgoings: Main Fire Pump :200Amp, 50Katpnmccb, Ics=100%Icu, Withfully Automatic Star / Delta Starter Suitable For 75 Hp Pump With Overloadprotection, Currentsensingtypesinglephase Preventorcompletewithallacceessoriesandinternal Wiringrequiredforautomaticoperation, Selectorswitch For Local / Remote, Auto / Manual / Off Operation. - 2 Setsjockey Pump:100 Amp, 50Ka Tpn Mccb, Ics=100% Icu, With Suitable Hp Fully Automatic Star / Delta Starter With Overload Protection, Currentsensingtypesinglephasepreventor Complete With All Acceessories And Internal Wiring Requiredforautomaticoperation, Selector Switchfor Local / Remote, Auto / Manual / Off Operation. - 2 Setsdiesel Engine Controla ) Control For Diesel Engine Comprising - Automatic / Manualselctorswitch&3Attemptsstarting Device, Timersandrelaysasrequired, Pushbuttons, Start / Stop In Manual Modeb ) Indicatinglampforhigh / Lowlub.Oilpressure, High Water Temp And Engine On Indicationc ) Batterychargersuitbalefor12v / 24Vdcwithboost And Trickle Selector Switch, 0-30 V Dc Volt Meter, And 020 A Dc Ammeter All Standard Relays And Accessories For Automatic Operation Of Diesel Engine.System Controller: Designing, Supply, Installation, Testingand Commissioning Of System Controller To Control Operation Of Main Electric Fire Pump, Diesel Pump, Pressurization Pump, Terrace Pump In Sequence As Per Specification Consisting Of Relays, Timers. Sensors, Annunciation Windowforfaultindication, Complete As Per Specification 6 Providinglaying, Testing&CommissioningofCClass Heavydutymspipeconformingtois1239 / 3589I / C Fittingslikeelbows, Tees, Flanges, Tapers, Nutsbolts, Gasketsetc.Ingroundincludingwelding, Excavation& Providingcementconcreteblocksassupports, Anticorrosivetreatmentwithcoaltar / Asphalttapeasper Is10221, Refillingthetrenchetc.Offollowingsizes Complete As Required. 200 Mm. Dia ( Wall Thickness = 6.3 Mm ) 7 150 Mm. Dia 8 Providing, Laying, Testing&Commissioningof CClass Heavydutymspipeconformingtois3589 / Is1239 Includingwelding, Fittingslikeelbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required : 25 Mm Dia 9 32 Mm Dia 10 40 Mm Dia 11 50 Mm Dia 12 65 Mm Dia 13 80 Mm Dia 14 100 Mm Dia 15 150 Mm Dia 16 Providing, Laying, Testing&CommissioningofBClass Heavydutyg.I.Pipeconformingtois1239including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts, Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Ormorecoatsofsyntheticenamelpaintofrequired Shade Complete As Required: 25 Mm 17 32 Mm 18 40 Mm 19 50 Mm 20 65 Mm 21 80 Mm 22 100 Mm 23 150 Mm 24 Supplyingandfixingsingleheadedinternalhydrant Valve With Instantaneous Gunmetal / Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheelisi Marked Conformingtois5290 ( Type-A ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 25 Supplying And Fixing Single Headed External Yard Hydrant Valve With 1 No. 63 Mm Dia Instantaneous Fm Gunmetal / Stainlesssteel Couplingand Cast Iron Wheel, Isimarked, Conformingtois5290 ( Typea ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 26 Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Markedcompletewithnuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required :80 Mm Dia 27 100 Mm Dia 28 150 Mm Dia 29 Supplying, Fixing, Testing&Commissioningofdouble Flangedsluicevalveofratingpn1.6Withnonrising Spindle, Bronze / Gunmetalseat, Isimarkedcomplete With Nuts, Bolts, Washers, Gaskets And Conforming To Is 780 Of Following Sizes As Required : 80Mm Dia 30 100Mm Dia 31 150Mm Dia 32 200Mm Dia 33 250Mm Dia 34 Supplyingandfixingorificeplatemadeoutof6mm Thick Stainless Steel ( Grade 304 ) With Orifice Of Required Sizetobefitted Betweenflange&Landingvalveof Externalandinternalhydrantstoreducepressureat The Outlettothe Levelof 3.5Kg / Cm2 Complete As Required. 35 Providing, Installation, Testingandcommissioningof Non-Returnvalveoffollowingsizesconfirmingtois: 5312 Complete With Rubber Gasket, Gi Bolts, Nuts, Washers Etc.As Required.100Mm Dia 36 150Mm Dia 37 200Mm Dia 38 Providing, Installation, Testingandcommissioningof Stainlesssteely-Strainerfabricatedoutof1.6Mm Thickstainlesssteel, Grade304, Sheetwith3mmdia Holes With Stainless Steel Flange.150Mm Dia 39 200Mm Dia 40 Supplying And Fixing 63 Mm Dia, 15 M Long Rrl Hose Pipewith63mmdiamaleandfemalecouplingsduly Boundwithgiwire, Rivetsetc.Conformingtois636 ( Type-A ) As Required : Gun Metal 41 Supplying Andfixing First-Aidhosereelwithms Constructionspraypaintedinpostofficered, Conformingtois884completewiththefollowingas Required. A ) . 20Mmnominalinternaldiawaterhosethermoplastic ( Textile Reinforced ) Type -2 As Per Is: 12585 B ) .20Mmnominalinternaldiagunmetalglobevalve& Nozzle. C ) .Drum And Brackets For Fixing The Equipmets On Wall.D ) .Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M.S. Pipe And Socket. E ) .40 M 42 Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Sizenozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required : Gun Metal 43 Supplyingandfixingoffirebrigadeconnectionof Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplingscompletewithcapandchainasreqd.For Suitabledia Ms Pipe Connectionconforming To Is 904 As Required :2 Way-100 Mm Dia M.S. Pipe 44 4 Way - 150 Mm Dia M.S. Pipe 45 3 Way - 150 Mm Dia M.S. Pipe 46 Supplying And Fixing Air Vessel Made Of 250 Mm Dia, 8 Mm Thick Ms Sheet, 1200 Mm In Height With Air Release Valveontopandflangedconnectiontoriser, Drain Arrangementwith25mmdiagunmetalwheelvalve Withrequiredaccessories, Pressuregaugeand Paintingwith Synthetic Enamel Paint Of Approved Shade As Required. 47 Providing, Fixing, Testing & Commissioning Of 15Mm Dia Quartzoidbulbtypesprinklersofrating68degree Centigrade With Required Accessories :Pendent Sprinkler 48 Upright Sprinkler 49 Horizontal Side Wall Sprinkler 50 Concealed Sprinkler 51 Providing & Fixing Of Pressure Switch In M.S. Pipe Line Including Connection Etc. As Required. 52 Providing& Fixingflowswitchinfollowingsizesm.S. Pipe Including Connection Etc As Required. 53 100Mm Dia 54 150Mm Dia 55 Providing, Fixing, Testing & Commissioning Of Installationcontrolvalveofcastironbody, Brass / Bronzeworking Partscomprisingofwater Motor Alarm, Bronzeseatclapper, Clapperarmand Hydraulicallydrivenmechanicalgongbelltosound Continuousalarmwhenthewetriser / Sprinklersystem Activates, Pressuregauges, Emergencyreleases, Strainer, Pressureswitch, Cockvalvecompletewith Drainvalveandbypass, Testcontrolbox, Ballvalves, Ms Pipe Of Required Size, Flanges, Orifice Plate, Gasket Etc Of Follwing Sizes Asrequired : 150Mm Dia 56 Supplying, Installation, Testing & Commissioning Of Sprinklerflexiblepipe ( Ullisted ) Ofstainlesssteel Complete With 15 Npt On Reducer Thread With Maximum Working Pressure Of 175 Psi Test Pressure Of 875Psi ( Burst ) Withbranchline ( Inlet ) 25Mmnpt Malethreadtosprinklerhead ( Outlet ) 15Mmnpt Femalethreadwithreducer, Nipple, 2Sidebrackets, Center Bracket, Stockbar Of Following Sizes Complete As Required.700Mm 57 1000Mm 58 1200Mm 59 1500Mm 60 Providing And Fixing In Position The Industrial Type Pressure Gauges With Gun Metal / Brass Valves Complete As Required ( E&M ) 61 Providing And Fixing Ms Cabinet ( Size 750X600x250 Mm ) Fabricated From 16 Gauge Ms Sheet With Full Front Glass Door & Locking Arrangement For Pad Lockwith Suitable Shelves For Keeping 25 Nos. Spare Sprinklers & One No. Spanner Properly Fixed In Shelves. Cabinet Shall Be Painted With Enamel Paint Of Approved Shade. ( Cost Shall Include 20 Nos. Spare Sprinklers ( 5 Nos Side Wall 20Nos Pendent, One No. Spanner And 5 Rolls Of Teflon Tape ) . Note: All Valves Shall Be Of Pn16 Rating 62 Portable Fire Extinguishers: Providing & Fixing Of Isi Marked ( Is:15683 ) Portable Fire Extinguisher, Carbondioxide Type Flat Base Including Valve, Discharge Hose Of Not Less Than 10 Mm Dia. 1 M Long & Complete In All Respects Including Initial Fill With Co2 Gas Confirming To Is:307-1966 Filled To A Filling Ratio Of Not More Than 0.667 Of Not More Than 0.667 And Wall Suspension Bracket Capacity 4.5 Kg 63 6 Kg. Abc Powder Type Fire Extinguishers Are Manufactured And Marked To Indian Standard Is: 15683. Suitable First Aid Appliance For Fighting Fires In Class A, B & C Fire That Is Wood, Textile, Flammable Liquids & Gases. 64 Providing And Fixing Mechanical Foam Type Fire Extingushers Consisting Of Welded M.S. Trolley Mounted Cylindrical Body, Squeeze Lever Discharge Valve Fitted With Pressure Discharge Hose, Discharge Nozzle, Trolley Etc., Isi Marked As Per Is:Is:13386 Finished Externally With Red Enamel Paint.Capacity 50 Lit ( D.G.Room ) 65 Providing And Fixing Carbon-Di-Oxide Fire Extingushers Trolley Mounted With All Accessories Internal Discharge Tube, High Pressure Discharge Hose, Discharge Nozzle, Isi Marked As Per Is:2878 Finished Externally With Red Enamel Paint. Capacity 22.5 Kg. 66 Boq-D: Plumbing Pump & Equipmentswater Supply, Drainage, Pumps & Equipment :Providingand Fixing Centralized Water Level Controller Cum Indicator System, As Per The Following Details:Centralised Plc Control Panel : Along With Touch-Screen Display Board ( Min. 8 Diag. Size ) Along With All Accessories For Complete Controls & Indication. Panel Shall Be Made Out Of Crca Sheet Min. 2Mm Thick Having Necessary Interlocks, I / OS, Required Number Of Repeater Amplifiers, All Audio-Visual Alarms As Required Specifications As Listed Below. An Emergency Stop Push Button Shall Be Provided In The Panel. The Panel Shall Have Modbus Compatibility For Seamless Bms / Bas Integration And Shall Be Of Approved Make. The Complete System Control Matrix, Wiring Diagram, SldS And Technical Details Shall Be Submitted By The Vendor And Gotten Approved Before Commencement Of Execution Of Works. Water Level Indicators Cum Controllers :Working On Hydrostatic Pressure Measurement Principle Made Of Stainless Steel For Installation On Storage Tanks, And Capable Of Providnig 4 To 20 Ma Analog Signal Compatiblewith Plc Signal Inputs And Completeas Per Working Requirements For Details Of Equipment Below. All Control Outputs To Mcc Panel Shall Be Included As Per Requierments. A ) .Fire Static Underground Tanksb ) .Real-Time Water Level Indication Monitoring 67 V. Low Level Audio-Visual Alarm At Less Than 25% Total Capacity.Raw Water Underground Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Tubewell Pumps At 35%Auto Cut-Out Of Tubewell Pumps At 95% 68 Auto Cut-Out Of Raw Water Pumps At 35%Domestic Water Underground Tanks Real-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Auto Cut-In Of Raw Water Pumps At 35% 69 Auto Cut-Out Of Domestic Water Pumps At 35% Flushing Water Underground Tanks At Stpreal-Time Water Level Indication Monitoringv. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity.V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Raw Water Pumps ( From Stp ) At 35% 70 Auto Cut-Out Of Flushing Water Pumps At 35% Domestic Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 71 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Flushing Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 72 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. 73 Providing Complete Testing Kit With All Chemicals Complete Suitable For Conducting Test On Water Quality.The Test Kit Shall Be Suitable To Measure Tds, Ph, Hardness, Iron Content And Other Parameters 74 Hydro-Pneumatic Pumping System For Domestic Supply To Fixture ( Toilet Kitchen ) : Providing, Fixing And Testing Of Packaged Type Skid Mounted Hydropneumatic System With Variable Frequency Drive Type Comprising Of : ( I ) Vertical, Inline Multistage Centrifugal Pumping Set With Stainless Steel Ss-304Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iecstandards And Gjl250 Cast Iron Suction& Discharge Casing, Connected To Tefc Ventilated Induction Motor Of2 Pole, 2900Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply. ( Ii ) Pressure Vessel Of Non Corrosivefrp Composite Construction Lined With Nsf And / Or Fda Listed Material, Likehigh Density Polyethylene With Fully Replaceable Polyurethane. Air Cell Burstpressure Of Minimum Of 5 Times The Vessel Operating Pressure And Cycle Tested For 2, 50, 000 Cycles. ( Iii ) Control Panel With Programmable Logic Controller ( Plc ) For Cyclic Operation Of Pumps + Variable Frequency Drive. The Pump Workingsequence Should Change After Every Operation.Contractor Overload Relays And Mcbs Should Confirm To Iec 898 – 1995 / Specifications. Blinking Indications For Pumps Start, Trip, Low Level Trip, Health Supply Should Be Provided In The Panel Along With The Ammeter& Voltmeter. Control Panel Should Also Consist Of Cooling Fan. ( Iv ) Pressure Switches Bellowtypefittedwithmicro Switch And Having Maximum Pressure And Differentialscaleshould Confirming Bs-6134 Standards And Ip55 Protection Class. ( V ) All Required Ball Valves, Non-Return Valves, Flexible Connectors Etc. And All Required Accessories, Heavy Duty S.S 316 Manifold To Make The System Completely Operational As A Skid Mounted System. Ball Valves Tobe Used Should Be Hot Pressed Brass Ot-58Withstainless Steelballand P.T.F.Eseal And O-Ring. Nrvs To Be Used Shouldbewithspringsando-Ring Arrangement. ( Vendor To Submit Performance Curves And Technical Catalog Of The Proposed Model For Review & Information ) Complete Manifold System Shall Be Factory Aasembled & Totally Mounted On A Common Base Frame With Following Duties:Note: Contractor To Note That The Suction Header Is Required To Have Inlet Connection From The Puddle Flange @ Water Tanks And To The Pump Suction. Provision Of Delivery Header Is Required To Have Outlet Connection From The Pumps. Suitable Outlet Flanges From The Delivery Mainfold / Header Shall Be Provided As Required.A.For Domestic Water Supply For Club & Benquet Hall: No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 350 Lpm Each Pump Head: 55 Meters Apx. Hp ( Motors ) : 3 Hp Location : Plumbing Plant Room 75 For Flushing Water Relift Pump :No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 250 Lpm Each Pump Head: 55 Metersapx. Hp ( Motors ) : 2 Hplocation : Stp Plant Room 76 Garden Hydrents & Floor Washing Relift Pump:Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty:No. Ofpumps :2 ( 1 Working +1 Standby ) Capacity: 200 Lpm Each Pumphead: 45 Metersapx. Hp ( Motors ) : 4 Hplocation : Stp Plant Room 77 Supply, Installation, Testing & Commissioning Of Continuous Duty Submersible Centrifugal Non-Clogging Drainage Pumps Of Efficiency Of Approved Make Complete With 3 Phase Motor With All Necessary Protection And Mechanical Seal Etc. Complete With All Ancillaries Including Float Type Level Controllers, Electrical Control Panels Fabricatd From 14 Gauge Crca Sheet Volt Meter Ammeter With Selector Switch, Tpmcb, 5 Va Cl : Cts, Phase Indicating Lamps Protected By 2 Amp Sp Mcb, Dol Starter, Necessary Wiring, Cable Alleys, Earthing, Interlocking, Starter With Automatic Float Type Level Controller, Providion Of High Level Alarm, Sequence Timer, Potential Free Contact To Starter For Connection To Bas, Both Pumps May Run Simultaneously At Pre Determind Level. ( 1 Working + 1 Standby ) Vendor To Submit Proposed Pump Model With Duty Curve.A ) . For Wtp & Stp Plant Room Drainage :Flow Rate : 450 Lpm Head : 15 Mtssolid Handling : 100 Mmlocation : Sump Of Basement Purpose : Plant Room & General Area Drainage Moc : Ss Body Ss Impeller & Shaft 78 B ) .For Basement Drainage : Flow Rate : 450 Lpm Head : 15 Mts Solid Handling : 100 Mmlocation : Sump Of Basement Purpose : Basement Area Drainage Moc : Ss Body Ss Impeller & Shaft 79 C ) .Manhole Cover For U.G Tanks And Sumps :Supplying And Fixing C.I. Cover Without Frame For Manholes :560Mm Diameter C.I Cover ( Heavy Duty ) The Weight Of The Cover To Be Not Less Than 108Kg. 80 F ) .Providing And Fixing Stainless Steel Ladder, Wall Mounted Of 4M Height ( App ) For Underground Tanks Complete With Flanged Ends And Inserts ( Removable Type ) Made Of 38Mm / 42Mm Dia 16 G S / S 304 Quality Pipe Made As Per International Quality Standards Of Approved Shape And Size With Non Skidding Stepsat 300Mm Vertical Spacing, Completeas Directed By The Engineer In Charge. 81 Water Treatment Plant: Providing & Fixing Vertical, Inline Multistage Centrifugalpumping Set ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) With Stainlesssteel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibration Elimination Pads Etc. Complete With Base And Frame, Nuts And Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Have Following Duty:A ) .For Club Building Only : No. Ofpumps: 2 ( 1 Working + 1 Standby ) Flow Rate :150 Lpm Each Head : 30 Mtsrequired For : Filter Feed Pump In Plumbing Plant Room ( 1Working + 1Standby ) 82 Providing And Fixing Vertical Pressure Filter With Dual Media Filter ( Comprising Of 600Mm Bed Depth Of Graded Sand Gravel And 600Mm Bed Depth Of Anthracite ) Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge : 150 Lpm Filtration Rate: 17500 Lit. / M2 / H Discharge : 150 Lpm Suggested Dia App.: 0.90 M 83 Activated Carbon Filter ( Domestic Water ) : Providing And Fixing Vertical Activated Carbon Filter Comprising Ofactivated Carbon Filter Media Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Epoxy Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge :100 Lpm Filtration Rate: 15000 Lit. / M2 / H Suggested Dia App.: 0.60 M 84 Providing, Fixing, Testing & Commissioning Of Msep Water Softening Plant ( Suitable For 3 Kg / Sqcm Workingpressure ) Complete With Initial Charge With T-40 Na Resin, Multiport Valve With Built In Ejector For Controlling All Operations ) , Regeneration System And Hdpe Tank, Pressure Gauge At Inlet, Outlet And Back Wash ( Each With Isolation Cock ) , Valves, Fittings And Water Hardness Testing Kit & Associatedworks. Softener Shall Be Suitable For The Following Duty:Note:The Successful Contractor Will Have To Carry Out A Test Of Raw Water From All The Sources Of Water For The Commercial, Residential & Apartment At Their Own Cost From A Reputed Lab As Approved By The Engineer-In-Charge / Consultant. On The Basis Of These Results The Contractor Has To Submit His Shop Drawings, Design Calculations And Specifications Accordingly.Please Note That It Is Ultimately The Responsibility Of The Contractor To Provide Treated Water For Different Use As Per International Standard As Given In The Attached Guidelines. Raw Water Hardness: 500 Mg / Ltreated Water Hardness:100 Mg / L Regeneration Period:12 Hrs.Capacity : 100 Lpm 85 Supplying, Installing, Testing And Commissioning Of Dosing System ( For Domestic Water Treatment Plant ) Consisting Of One Hdpe Tank Of 100 Litres Capacity With A Positive Displacement Diphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240 V / Single Phase / 50 Hz. Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers, Low Level Switch Andinjection Fittings. The Pump Shall Be Speed & Stroke Control Asialmi / Equivalent Make. The Cost Shall Be Inclusive Of Providing Salt For The Testing And Operation Of System Before Handover To The Owner. 86 Plumbing Panel: Design, Manufacture, Assembly, Wiring, Testing At Works And Supply To Site Of Following Panels / Distribution Boards / Switch Boards. The Boards Shall Be Designed And Fabricated As Per General Specifications, Technical Details, Specifications And Notes As Part Of This Tender / Boq And Relevant Bis Codes. ( Any Load Veriation In System As Technical Document Of Manifactureno Cost Shall Be Paid Extra For System Requirments ) Ip Rating: Ip 54 Incomer:1 No. 250 A 25 Ka, 3P Mccb Of Motor Duty - Only Magnetic Release. ( Adjustable Magnetic Release Upto 250A Mccb Or Micro-Processor Based Release Above 250A Mccb ) .Incomer Metering & Indication: A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt.B ) .R, Y, B Phase Indication Lamps ( 110V ) Led Type C ) .Cast Resin Metering CtS For Each Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio D ) .1 No. Digital Vaf + Pf Meter ( 110V ) ( *With / Without Rs 485 Port ) Bus Bars : 400A, Tp, Aluminium Bus Bars Of Electrolytic Grade With Heat Shrinkable Sleeves 25 Ka. Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) .B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer.C ) .110V Control Circuiting D ) .110V Control Supply Healthy Indication ( Led Type ) .Outgoings: A ) .Dol Starter Comprising The Following ( For Upto 2 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) . For 1Hp. ( 2 Nos. ) ( Chamical Dosingpump ) B ) .Type-2 Co-Ordinationc ) . 1 No. Suitable Rated Tp Mpcb, 10Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) . On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) .On / Off Push Buttons G ) Star-Delta Timerh.2 Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy & Of Suitable Burden & Ratio. J ) .Digital Ammeter K ) .On / Off-Trip / A / M Potential Free Contacts For Bmsl ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.B ) .Dol Starter Comprising The Following ( For 3 Hp To 5 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan :A ) For 4 Hp. ( 2 Nos. ) ( For Pump Room Exhaust Air Fan ) B ) Type-2 Co-Ordination C ) 1 No. Suitable Rated Tp Mpcb, 25 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) 2 Pole A / M Selector Switch For Bms Application G ) Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioh ) Digital Ammeter With Inbuilt Selector Switch I ) Digital Ammeter J ) On / Off-Trip / A / M Potential Free Contacts For Bmsk ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.C ) .Dol Starter Comprising The Following ( For 7.5 Hp To 10 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) For 7.5Hp. ( 2 Nos. ) ( Raw Water / Filter Feedpump ) B ) . For 6 Hp. ( 2 Nos. ) ( Soft Water Reliftingpump ) C ) .Type-2 Co-Ordinationd ) .1 No. Suitable Rated Tp Mpcb, 10 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) E ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contacts F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .On / Off Push Buttons ( With Lockable Off ) H ) . Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioj ) .Digital Ammeter With Inbuilt Selector Switch K ) On / Off-Trip / A / M Potential Free Contacts For Bms L ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. D ) .Star-Delta Starter Comprising The Following ( For 12.5 Hp To 25 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) .12.5 Hp. ( 3 Nos. ) ( Tubewells Pump ) B ) .Type-2 Co-Ordinationc ) .1 No. Suitable Rated Tp Mpcb, -----Ka, Without Inbuilt O / L Relay ( Only Magnetic ) D ) .Suitable Sized 3P Contactors ( Star, Delta & Run Contactors ) With 2 No & 2 Nc Auxiliary Contactse ) Suitable O / L Relay With Inbuilt Spp F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .2 Pole A / M Selector Switch For Bms Application H ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioi ) Digital H Inbuilt Selector Switch J ) On / Off-Trip / A / M Potential Free Contacts For Bms K ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. Feeders ( Without Starters ) For Hydronumatic Pump Panels :1 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 10 Hp Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For Sump Pump Panels : 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 15 Hp Sewarage Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For R.O Water Booster Pump Panels : 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 3 Hp R.O Waterbooster Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Spare Starter Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Starter Feeders:5 Hp Motors, Dol Starter ( 2 Nos. ) ( Spare Feeders ) Spare Motor Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Feeders: 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 10 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 5 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Vendor Can Also Consider Integrated Total Co-Ordinated Starter Upto 15Hp.Plumbing Panel As Described Above. 87 Sump Pump Panel ( Upto 5.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. 3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .E ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( Upto 5.0Hp Motors ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 88 Sump Pump Panel ( For 7.5Hp To 10.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. B ) .3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.C ) .R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.D ) .Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( For7.5Hp To 10.0Hp Motor ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering Oneach Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 89 Sewage Treatment Plant:Sewage Treatment Plant Based On Mbbr ( Moving Bed Bio Reactor ) Technology :Supply, Installation, Testing And Commissioning Of Package Type Pre-Fabricated Sewage Treatment Plant Based On Mbbr Technology ( Moving Bed Aerobic Bio-Reactor ) Of 65 Kld Capacity Including All Ms Structure, Mechanical, Electrical And Instrumentation Works As Per Technical Specification Mentioned In The Document. The Scope Shall Also Include To Provide The Ss Bar Screen In Grit Screen Chambers, Grease Separator, Primary & Secondary Treatment Of Waste Water, Air Blowers, All Necessary Interconnecting Piping & Valves, Pumps, Dmf And Acf Filters, Chlorinator, Ultravoilet Dis-Infection Unit, Mcc For Operation Of All Motors, All Inter Connecting Power And Control Wiring, Level Controllers & Other Controls, Ms Puddle Flange ( Hot Dip Galvanized After Fabrication ) , Inlet, Outlet, Overflow, Vent, Manhole Cover Etc, Completed In All Respect In Ready To Use And Easy To Transport Condition. ( The Entire System Tobe Installed Above Ground ) .A ) .Nature Of Effluent - Domestic Sewage From Toilets / Kitchen.B ) .Flow Rate - 65 Kld C ) .Sewage Incoming Characteristics D ) .Ph - 6.5 - 8.5 E ) .Bod5 - Upto 250 - 400 Mg / L F ) .S. Solid - 250 To 450 Mg / Lg ) .Cod 5 - Upto 600 Mg / L H ) .Oil & Grease - 50 Mg / L I ) .Effluent Discharge Standard After Treatment J ) .Ph - 6.5 - 7.5K ) .Bod5 - Less Than 10 Mg / L L ) .S. Solids - Less Than 10 Mg / L M ) .Cod - Less Than80 Mg / L N ) .Oil & Grease - Less Than 5 Mg / L Sewage Treatment Plant Shall Include The Following Items:A ) .Oil & Grease Chamber B ) . Sewage Equalization Tank C ) .Mbbr Tank ( Moving Bed Bio Reactor ) D ) .Tube Settling Tanke ) .Sludge Holding Tank F ) .Chlorine Contact Tank G ) .Filtration Through Mgf, Acf, Chlorinator & Uv Sterlizerh ) .Air Blowers, Pumps & Equipmenti ) .Filter Pressj ) .Piping, Valves Etc K ) .Electrical Panel & Cablingl ) .All Piping, Valves & Level Indicator / Controller Etc. Within Plant Room. Note: A ) .Contractor Shall Ensure Submission Of Detailed Civil General Arrangement Drawings ( Plan & Section ) , P & I ( Programming & Instrumentation ) Diagram, Schematic Diagram For The Above Mention Component & Additional Component Such As Inserts, Puddle Flanges, Vent Pipes Etc. If So Required For The Complete Working Of The Stp And Got It Approved By The Engineer In Charge. B ) .Only Plateform For Stp Plant Shall Be In The Scope Of The Owners. The Sewerage Treatment Contractor Shall Co-Ordinate, Supervise And Get All The Inserts Installed. All Supply Of Ms / Insert Plates Shall Be In The Scope Of The Sewerage Treatment Contractor.Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) C ) .Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) D ) .Supply, Installation, Testing And Commissioning Of The Following Tanks And Chambers In Hdpe / Pvc As Per Approved Drawings And Directions Of Engineer Incharge. The Cost Shall Include All The Required Mswalking Platform, Handrail, Staircase, Manhole Cover Etc. All Above Quoted With Minimum 10Mm M.S Tanks With 5Mm Frp Coating Protectiona ) .Mbbr Tank Of Capacity 25000 Litersb ) .Tube Settler Tank Of M Sc ) .Sludge Holding Tank Of Capacity 5000 Litresd ) .Chlorine Contact Tank Of Capacity 10000 Litrese ) .Treated Water Tank Of Capacity 15000 Litres Quoted With Minimum 10Mm M.S Tanks And All Above Item As Per Design Requirments ( No Extra Payment Shall Be Paid ) 90 Supply, Installation, Testing & Commissioning Of Horizontal Type Pumps, Having Cast Iron Body, C.I. Impeller & Shaft Connected To Tefc Motor For 415 Volts, 3 Phase, 50 Cycles A.C. Power Supply Withmechanical / Gland Seal. Protection Complete In All Respects Including Suction And Delivery Headers With Upvc Pipe Of Required Dia, Isolation Valves, Nrv & Pumps Shall Have Following Duty: A ) .Raw Sewage Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 40 Mm Size ) Set Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 2.5 Lps ( Required- 2.5M3 / Hr ) Head - 10-12 Mtr.H.P.-2 Hp Approx. 91 B ) .Submersible Sewage Lifting Pumpset Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 1.5 Lpshead - 10-12 Mtr.H.P.-2 Hp Approx. ( Solid Handling Capacity Upto 40 Mm Size ) 92 Supply, Installation, Testing & Commissioning Of Electromagnetic Type Flow Meter At The Outlet Point Of Raw Sewage Transfer Pump Of 50 Mm Size Suitable For 0 - 15 Klh Flow. 93 Supply, Installation, Testing & Commissioning Of Twin Type Rotary Air Blower With Acoustic Encloser, Driven Through “V” Belt Or Directly Coupled Through Flexible Coupling To A Tefc Motor Of Suitable Hp Suitable For 415 ± 10% Volts, 3 Phase, 50 Cycles A / C Supply. Capable Of Delivering 70 Cum / Hr Of Free Air At 0.5 Kg / Cm2. 94 Supply, Installation, Testing & Commissioning Of Air Piping Shall Comprise Of Pipes Droppers / Laterals With Ms ( Epoxy Coated ) Header Complete With All Fittings Such As Tees, Crosses, Plugs, Sockets, Elbows, Reducers, Supports & Clamps, Puddle Flanges Etc Including Cutting Holes In Wall, Makes Chases In Wall And Making Good The Same. Contractor To Submit Detailed P&I Indicating Their Proposal. 95 Supply, Installation, Testing & Commissioning Of Fine Air Diffusers Capable Of Delivering 10-12 Cum / Hr In Mbbr Tank For Providing Areation. 96 Supply, Installation, Testing & Commissioning Of Coarse Air Diffusers Capable Of Delivering 3-6 Cum / Hr In Equalization Tank And Sludge Holding Tank For Providing Areation. 97 Supply, Installation, Testing And Commissioning Of High Surface Area @ 400 M2 / M3 At Least Ring Type Media To Be Used For Bacterial Growth Installed In Moving Bed Bio Reactor Tanks. 98 Supply, Installation, Testing And Commissioning Of Pvc Tube Deck Settling Media To Be Installed In Tube Settling Tank. The Media To Be Supported On Msep Frame With Baffle Plate & Overflow Launder. 99 Supply, Installation, Testing And Commissioning Of Single Stage Horizontal Centrifugal Self Priming Pump With With C.I Body, Bronze Impeller, Shaft Of Stainless Steel, Shaft Sleeve Of Chrome Steel And Delivery Casing In C.I With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415+ / - 10%Volts, 3Phase50 Cycles A.C. Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Sequence Running Controller, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Includingisolation Valves, Nrv & Vibration Eliminators On Both Suction & Delivery Side Of Pumps .Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information. A ) .Sludge Feed / Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 8-10 Mm Size ) B ) .Set Of Two Pumps ( 1 Working + 1 Standby ) C ) . Capacity- 1.5 Lpsd ) .Head - 10.0 Mtr. E ) .H.P.-1.5 Hp Approx. 100 Supply, Installation, Testing And Commissioning Of Horizontal Centrifugal Pumping Set With Cast Iron Body, Bronze Impeller, Shaft Of Ss And C.I. Base & Head With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415 + / - 10%Volts, 3 Phase 50 Cycles A.C Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Including Isolation Valves, Vibration Eliminators On Both Suction & Delivery Side Of Pumps And Nrv On Delivery Side Of Pumps Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information.A ) .Filter Feed Pumpsb.Set Of Two Pumps ( 1 Working + 1 Standby ) C ) .Capacity- 3.0 Lps ( Suggested And Quoted For 5000Lph ) D ) .Head - 30.0 Mtr.E ) .H.P.-3.0 Hp Approx. 101 Supply, Installation, Testing & Commissioning Of Vertical Self Supporting Filtration Unit Fabricated From Ms Sheet As Per Is: 2825 ( Minimum Thickness Of Shell 8 Mm And Dished Ends 10 Mm ) Pressure Gauges, Sample Cock, Gi Class C Face Piping, Ci Butterfly Valves And All Accessories, With Initial Charge Of Filter Media Including Anthracite, Painting Inside With Epoxy Paint And Outside With Two Coat Of Red Oxide Primer And Two Or More Coat Of Synthetic Enamel Paint, Testingand Commissioning Complete.A ) .Mulitgrade Pressure Sand Filtercapacity - 5000 Lph Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm. Test Pressure : 4. 5 Kg / Sq Cm 102 B ) .Activated Carbon Filter Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm.Test Pressure : 4. 5 Kg / Sq Cm 103 Supply, Installation, Testing & Commissioning Of Metering Pump Type Chemical Doser With 100 Lits. Pvc / Hdpe Solution Tank, Injection Fitting Assembly, Suction And Delivery Hose Upto The Point Of Injection, Capacity 0-6 Lph, Complete In All Respects. 104 Supply, Installation, Testing & Commissioning Of Ultravoilet Dis-Infection Unit. The Unit Shall Have Over 99.9 % Bacterial Reduction From Inlet To Outlet. The Dis-Infection Chamber Shall Be Constructed Of Ss 316L On All Welted Parts. The Uv Lamp Shall Be Of Low Pressure Mercury Vapour Type With Hard Glass Enclosure, The Sockets Shall Be Water Tight & Vibration Resistant. The Lamp Life Shall Be Rated For 6000 Hours. The Unit Shall Be Complete With Temperature Safety Control, Lamp Out Alert Circuit & Uv Radiometer With 4 – 20 Ma Output. The Uv Unit Shall Have With Reactor, Cabinet Housing, Cabinet Cooling, Treatment Chamber, Electrical Panel, Temperature Safety Control, Lampout Alert, Uv Radiometer Along With Uv Monitoring System And Uv Monitoring Readout Panel.The Uv Dosage Should Be > 60, 000 Uw – Sec / Sq.Cm. The Lamps Should Be Selected Based Upon The Flow Requirement Of Respective Unit.Flow Rate : 5 Cum / Hr 105 Supply, Installation, Testing & Commissioning Of All Pipings ( As Described Below ) And Isolation Control Valves Including All Necessary Fittings And Clamps, Supports, Hangers As Required I / C Cutting And Making Good The Walls Wherever Required Complete In All Respects For Making The System Complete.A ) .Gi : Submerged Air Piping ( We Suggest Upvc. Gi Is Never Used For Submerged Piping ) Ms Epoxy: Air Piping & Pumped Effluent Riser ( Non-Submerged ) Upvc : Interconnecting Pipe Line After Delivery Header Of Pump / Filtercontrollers With Low Voltage Relays, Stainless Steel Probes And Pvc Shroud, Control Cabling As Required Length. ( No Of Probes As Required For Function Of Each Controller ) . 106 B ) .Filter Feed Pumps To Cut Off Duty Pump On Low Water Level In The Chlorine Contact Tank And High Water Level In The Treated Water Tank And To Start Pump At Low Water Level In The Treated Water Tank. 107 Supply, Installation, Testing & Commissioning Of Filter Press Of Plate Size 18X 18X 12 Nos. Plate With Screw Feed Pumps Of 5 M3 / Hr @ 40 M Head Capacity ( 1 Working + 1 Standby ) Complete In All Respects. 108 Providing Installing Testing And Commissioning Of Ultra Filteration ( Uf ) System For Further Polishing Treated Effluent And Capable Of Producing 5, 000 Litre / Hour. The System Shall Be Complete With Uf Feed Pumps ( 1W+1S ) , Backwash Pumps ( 1W+1S ) , Cartridge Filters ( Fabricated| ) , Uf Membranes Flushing / Cleaning System Complete Instrumentation For Automation And Monitoring Rotameters Pressure Gauges Interconnecting Pipeword Electrical Cabling And Switchgear, All Complete Electrical Installation For Stp 109 Design, Fabrication, Assembling, Wiring, Supply, Installation, Testing And Commissioning Of Motor Control Centre Fabricated Out Of 14 Gauge Crca Sheet Steel. Cable Gland Plates Shall Be Provided On Top As Well As At The Bottom Of The Panels. Panels Shall Be Treated With All Anticorrosive Process Before Painting As Per Specifications With 2 Coats Of Red Oxide Primer And Final Approved Shade Of Powder Coated Paint. 2 Nos. Earthing Terminals Shall Be Provided For 3 Phase, 4 Wire, 50 Hz Supply System. Lifting Hooks Shall Also Be Provided In Case Of Large Panels. Approval Shall Be Taken For Each Panel Before Fabrication. Quoted Rates Shall Be Inclusive Of Cables ( In Accordance To Specification ) With Earthing From Panel To Each Motor / Equipment.Motor Control Centreincoming: A ) .200 Amps Tpn Mccb With The Following Accessories:B ) .0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.C ) .0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set. D ) .Pharse Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets. Bus Bar:A ) .200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing; A ) .10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For ‘On / Off / Trip’ Status Of Motor B ) .Spare 25 Amps TpnmcbS2 Nos. C ) .Spare 32 Amps TpnmcbS2 Nos. D ) .Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Mcc For All Stp Equipments / Pumps As Described Above.Notes : A ) .All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.B ) .All Motor Starters Shall Be Provided With Automatic Level Controller. C ) .Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors . Motor Control Centre Incoming 200 Amps Tpn Mccb With The Following Accessories:0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set.Phase Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets.Bus Bar 200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For‘On / Off / Trip’ Status Of Motorspare 25 Amps TpnmcbS2 Nos. Spare 32 Amps TpnmcbS2 Nos. Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Notes : All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.All Motor Starters Shall Be Provided With Automatic Level Controller.Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors .Provision Shall Be Made For Providing Potential Free Contacts To All Pumps Starters.Mcc For All Stp Equipments / Pumps As Described Above. Sub Total Of Part A 110 Part B ( O & M Cost ) ( For 5 Years ( 60 Months ) From Final Handing Over Of All Works. ) ( Optional ) Trained Operator To Operate The Stp Round The Clockincluding Operator And Regular Visit Of Supervisor. Perannum Including All Charges Like Amc , Monthly Charges Of Water Analysis And All Consumables Etc Included. Sub Total Of Part B ( Rate Only ) 111 Part:C Providing & Laying Upvc Pressure Pipes Of 6 Kg / Sq.Cm Pressure Rating Class 3 ( Is : 4985-2000 ) Including Fittings, Tees, Bends, Clamps, Coupling And Adaptors Supports, And Jointing With Solvent Joint, Testing And Necessary Earth Work In Excavation, Backfilling, Disposal Of Surplus Earth With A Lead Up To 100M Complete, Compaction And Consolidation Including Sand Bedding All Around Upvc Pipe & Fittings And Thrust Blocks At Bends As Per Standard Design.200Od 112 Constructing Rccchamber Of Holding Capacity 10 M3 With Grade Of M25 Including Cost Of Centering , Shuttering & Pcc Below Foundation In 1: 5:10 & 75 Mm Thick And Inside Chamber Of 75Mm Thick As Per Standard Design Including Inside Plastering With Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design .Rate To Include Cost Of Reinforcement , Excavation And Filling Of Earth. Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. The Contractor Has To Detect Different Unilities Like Sewer Line , Water Supply Line , Electrical Cable , Telephone Cable , Gas Pipe Line Etc. Using Utility Detecting Machine Before Start Of Excavation And Shall Start Excavation Only After Getting Permission Of Engineer In Charge.All Kinds Of Soil.Depth Upto 1.5M From Existing Ground Level 113 B ) Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 114 Providing & Laying Cement Concrete - All Works Upto Plinth Level : C ) 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 115 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. ( Note :- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess / Less Cement Used As Per Design Mix Is Payable / Recoverable Separately ) . A ) Uptoplinth 116 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.B ) Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 117 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : C ) Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 118 D ) Suspended Floors, Roofs, Landings, Balconies And Access Platform 119 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 10 In Foundation And Plinth In: A ) Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) For 230Mm Thick Brick Work 120 B ) 12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 121 C ) 15 Mm Cement Plaster On Rough Side Of Single Orbrick Wall Of Mix:1:4 ( 1 Cement: 4 Fine Sand ) 122 D ) 6 Mm Cement Plaster Of Mix :1:3 ( 1 Cement : 3 Fine Sand ) 123 Designing, Preparation Of Shop Drawings, Supplying, Erection, Testing, Commissioning Of All Mechanical, Electrical And Other Components Including Getting Approval Of Successful Test Results From Approved / Authorized Agency From Pollution & Environmental Authorities, Operating & Maintaining Upto Successful Commissioning, For 5 M3 / Day Capacity Sewage Treatment Plant Sewage Treatment Plant Near Workshop Area ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) Suprime / Sintex Maketotal C / F To Summary 124 R.O Water Treatmentplant: Supply, Installation, Testing And Commissioning Of R.O. Plant Capacity Of 750 Lph ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) For The Following Parameters And Consisting Of ( But Not Limited To ) The Following Main Components:- ( I ) Inlet Quantity : As Per Detailing ( Ii ) Output Quantity : 750 Lph ( Iii ) Inlet Tds : 600 Ppm ( Iv ) Outlet Tds : 75 Ppm ( V ) Inlet Hardness : 350 Ppm ) ( Vi ) Outlet Hardness : 50 Ppm ) Raw Water Pumps Of Horizontal, Centrifugal Type Suitable For A Flow Rate Of 1500 Lph At 25M Head. The Pump Construction Shall Be Of Ss-304 & Impeller Shall Be Also Ss-304. The Motor Shall Be Tefc Suitable For A Supply Of 415V / 3-Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundations, Bolts, Pressure Gauge At Inlet And Outlet Of Each Pump. -- 2 Nos. ( 1W+1S ) Special Antiscalant Dosing System Consisting Of One Hdpe Tank Of 100 Litre Capacity With A Positive Displacement Diaphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240V / Single Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers & Injection Fittings. -- 1 Set Micron Cartridge Filter Suitable For A Flowrate Of 1500 Lph To Achieve Particle Filtration Of Less Than 5 Microns. The Unit Shall Be Supplied Complete With Inlet And Outlet Branches Removal Cap For Replacement Of Element, Inlet And Outlet Pressure Indicators. ( One For The Pressure Treatment & Other For Cip System ) Moc: Polypropylene -- 2 Sets R.O High Pressure Feed Pumps Of Vertical, Multistage Centrifugal Type Suitable For A Flowrate Of2000 Lph At 14 Kg / Sq.Cm. The Pump Construction Shall Be Of Ss-316-L & Impeller Shall Be Also Ss-316-L. The Motor Shall Be Of Tefc Suitable For A Supply Of 415V / 3 Phase / 50 Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundation, Bolt, Pressure Gauge At Inlet And Outlet Of Each Pump.- 2 Nos.R.O. Modules Made Out Of Spiral Wound Thin Film Composite Suitable To Withstand Pressure Of 20Kg / Sq.Cm. Suitable Bspt / Npt Connections Shall Be Used For Connecting Feed & Reject Ends. The Modules Shall Be Supplied Complete With All Necessary Instrumentation, Valves For Sampling, Drain, Reject & Permeate, Epoxy-Coated Structural Steel Bases And Supports, As Per Following System Capacity Requirements: ( I ) Total Net Treated Water Output Of System = 750 Lph ( Ii ) System Recovery= 50 - 60 % ( Iii ) Filtration Area Per Membrane = 85 Sq.Ft. ( Iv ) Number Of Membranes = The Total Number Of Membranes Required Shall Beas Per Requirements, Supported By Calculations From The Vendor. Centralised Plc Control Panelalong With Touch-Screen Digitial Display Board Along With All Digital Sensors For Tds & Flow, Made Out Of Crca Sheet Min. 2Mm Thick Having Main Contactors For All Pumps ( Listed Above ) Including Spp, 3 Phase Thermal Overload Relay. The Control Panel For Monitoring And Control Of P.O. System Shall Include All Required Signal Lamps, Hrc Fuses, Annunciation Box With Hooter. All Control And Power Cabling Along With Double Earthing Between The Panel Shall Be Included In The Scope Of Supply Of The Contractor. An Emergency Stop Push Button Shall Be Provided In The Panel. The Mcc Panel Shall Have The Following Interlocks:- I ) High Pressure Pump Unit Trip In Case Of Low Suction Pressure. Ii ) High Pressure Pump Unit Trip In Case Of High Discharge Pressure.Iii ) Special Anti-Scalant Dosing Pump Trips In Case High Pressure Pump Trips And Vice Versa.Iv ) High Pressure Pump Trip In Case Of High Conductivity In Permeate.V ) Shc Dosing Pump Trips Incase High Pressure Pump Trips And Vice Versa. Vi ) Orp With Dump Valve.-- 1 Seti ) First Fill Of All Chemicals And Lubricants To Commission And Operate The Plants. --1Lotj ) All Interconnecting Piping Work With Valves:- I ) Low Pressure Side Till R.O. Feed Water Pump. Piping Shall Be Of Extra Strong Pvc And All Valves Shall Be Of Extra Strong Pvc And All Valves Shall Be Pvc Ball Valves. -- 1 Lotii ) High Pressure Side Piping From The R.O. High Pressure Pumps To The Reject Stream Control Valves Shall Be Of Ss - 304 Using All Ss Fittings Ball Valves Of Suitable Pressure Rating Shall Be Used Till 25 Mm Size, Above 25 Mm, Flanged Globe / Wafer Butterfly Valves In Ss Construction Shall Be Used. Rejects Pressure Control Valves Shall Be Globe Valve And Feed Flow Control Valve Shall Be Of Ss-304. -- Lotiii ) Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants. ( All For Above From A To J Complete ) 125 R.O Water Storage Complete 316 Stainless Steel Treated Water Storage Tank ( Double Wall ) Of Capacity 2000 Litres Including All Inlet / Outlet Connections, Accessories, Valves, Double Seal Manhole Covers, Insulation Etc.The Stainless Steel Tank Must Be Ozone Resistant And To Be Used As Ozone Contact Tank. Fabrication To Be Done As Per Approved Shop Drawing. ( Make :Nector ) 126 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflowpipes But Without Fittings And The Base Support For Tank.. 127 Activated Carbon Filter ( Automatic Type For Online Installation Before The Micron Filters ) Suitable For A Flow Rate Of 1500 Lph. The Material Of Construction Shall Be Composite Frp. The Unit Shall Be Supplied Complete With Multi-Port Valves, Inlet And Outlet Branches Removal Caps Of Replacement Of Elements Inlet And Outlet Pressure Indicators. -- 1 Set 128 Hydropneumatic System For R.O Supply Providing Fixing And Commissioning Suitable Complete Composite Hydropneumatic System Consisting Ofhorizontal / Vertical Multistage Centrifugal Pump Having Stainless Steel Impellers, Stainlesssteel Shaft, Stainless Housing And Single Mechanical Seal And Pressurised Tankof Required Specifications And Of Non-Toxic Rubber Diaphragm, Complete With All Accessories Including Pressure Switch, Pressure Gauge And Electrical Panel With All Necessary Protection And Operational Devices I.E Alternate Pumping Operation And Shut Off During Dry Running Conditions Etc., And Inclusive Of Ss 316 Suction And Delivery Manifold Of Required Size With Non-Return Valve And Ball Valveand Withsuitableelectrical Motor To Be Operated On 210 / 220 Or 400 / 440 Volt 50 Cycle Suitable For Following Duty And With Total No. Of Pumps - 2 Nos. ( 1 Working+ 1 Standby ) Complete With The Approval Of Engineer-In-Charge.- Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants.A ) Discharge:150 Lpmb ) Head:45 M C ) App. Capacity Of Thevessel ( Frp ) : As Requiredtotal C / O To Summary 129 Hot Waterboilers And Other Related Accessories Electrical Hot Water Generators System With Solar Back Up.Hot Water Mixing Storage Tank ( 2 Sets For Club And Benquet Hall ) Supply, Installation, Testing And Commissioningof Solarwater Heating System Capable Of Generating 7500Lpd Of Hot Water Per Day At 60 Oc Along Withinsulated Horizontalhot Watermixing Tank Capacityand Design Code I.S: 2825 Fabricatedof 6 Mm Thick S.S. 304Plateand 10 Mmthickdishedend And Nozzles Complete With Inlet, Cold Waterinlet / Outlet Chain Connection Withflanges, Manhole With Bolted Cover With 72 Kw Electrical Back Up Along With Control Panels . Tankshall Beinsulated With 50 Mm Thickresin Bondedfibre Glass ( Density 24 Kg / Cum ) And Covered With500gpolythene Sheetand 24 Gauge Aluminumsheet Cladding Giving Proper Overlaps And Sealing The Joints With Suitable Adhesive Compound, Including The Following Additional Accessories / Specifications:Working Pressure : 7.5 Kg / Cm²i ) Safety Valveii ) Dial Type Thermometer Iii ) Thermowell For Thermostat Elements Cold Water Inlet Valve 80 Mm Dia Check Valve In Cold Water Inlet 80 Mm Dia.Hot Water Inlet / Outletsecondary Side 50 Mm Dia Valve Plate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Diaplate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Dia Hot Water Return Inlet 65 Mm Dia Drain Valve 50 Mm Diaair Release Valve 25Mm Diahot Water Return Nrv 65 Mm Dia Solar Pre Heating Working Inlet 80 Mm Dia Butterfly Valvesolar Pre Heating Working Inlet 80 Mm Dia Nrv Electrical Control Panel As Per Approved Apecification Temp. Controller 130 Hot Water Returnpumps For Domestic Waterprovidingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Dutynos : 2 ( 1 W +1 S ) Capacity: App.100 Lpm Head :15 M 131 Solar Hot Water Re-Curculation Pumps : Providingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Duty Nos : 2 ( 1 W +1 S ) Capacity: App100 Lpm Head :55 M 132 Electrical Panel Providing Motor Control Centres Fabricated From 16 Gauges M.S. Sheet With Powder Coated Finish. The Control Panels Should Be Comparable With H.P. Of The Motor As Specified.For Hot Water , Steam Genration Systemshot Water Recuculation Pumps, Hot Water Supply Pumps Condensate Pumps Etc.A ) One Incoming Main Isolation Mccb Of Required Rating.B ) Fully Taped Aluminum Bus Bar Ofrequiredcapacity In A Separate Bus Bar Chamber.C ) Isolation Switch Units With Mccbof Required Rating, For Each Unit.D ) Fully Automatic Dol Starter With Pushbutton And On / Off Indicating Lights For Each Unit, For Following Requirements:I ) Hot Water Boilers 2 Nos. Of Required 74 Kw Eachii ) Hot Water Re-Circulation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hp Iii ) Solar Hot Water Recirculation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hpiv ) One No. Spare Feeder Required 5 Hprotary Switches For Auto / Manual On / Off Operations For Each Unit.Rotary Duty Selector Switches.Panel Type Voltmeter 150Mm With Rotary Selector Switch For Reading Voltage Between Phases.Neon Phases Indicating Lights On The Incoming Mains. Single Phasepreventorfor Each Motor. Ct Operated Relayall Internal Wiring Colour Coded From Incoming Mains To Various Switchgear, Starter, Meter, Indicating Lamp And Bus Bar. All The Cable Entry To The Panel Shall Be From The Top. ( All For Above From Item ( A ) To ( L ) Complete Set ) . ( The Shop Drawing To Be Preparedand Approved Before Fabrication ) Total C / O To Summary 133 Swimming Pool Filteration System Recirculation Pumps Main Pool + Jacuzziarea : 550 M2 X 1.2 M Balancing Tank : 60 M3total Pool Volume : 660 M3 + 60 M3 = 720 M3filtration Flow Rate : 180M3 / Hr Filtration Plant With Pumpsupply, Instalation, Testing & Commissioning Of Bobbin Wound Side Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Fitted With Collector Arms And Diffuser Made From Unplasticised Pvc And Polypropylenewith Lid In Polyester Resin And Fibre Glass, Manual Air Purgeand 4 Pvc Flanged Connection For Inlet And Outlet, Pressure Gauge, Water Drain / Empty Drain For Filter Etc.Complete In All Respects. Including Corse & Fine Silica Sand Media For Filterapx. 7200Kgcapacity 60000 Ltrs / Hrdesign @30000 Ltrs / Sqm / Hr.Diameter1600 Mm Working Pressure4.0 Kg / Cm² 134 Valve Battery Valve Battery Manifold Made In Pvc With Flanges For Connecting To Filters Consists Of Set Of 5 - Buttterfly Valves For Carrying Out Filtration, Back-Washing, Rinsing And Shut Down Of The Filters. Size : 4 Inchsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) 135 Supply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) Capacity60000 Ltrs / Hrhead 16 Mtrhp 7.5, Three Phase 136 Swimming Pool U.V. Sterlizersupply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 60000 Ltr / Hrworking Pressure = 4.0 Kg / Sqm Uv Lamp Wattage = 400 W 137 Dosing Pumpsupply, Instalation, Testing & Commissioning Of Chemical Dosing Pumpfor Chlorination With 200 Ltrs. Sintex Tank And Accessories Capacity0-20 Litres / Hr.Head35 M 138 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 400X400 Mm 139 Inlet Nozzlesupply, Instalation, Testing & Commissioning Of Flow Adjastable Abs Inlet Nozzles Uv Treated With S.S. Screws To Fit In The 2 Pvc Pipes 140 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 141 Supply, Instalation, Testing & Commissioning Of Stainless Laddersteel 316 Ladders, Width: 500Mm Wide, Handrails Dia 43Mm Stainless Steel, Non-Slip Stepsprovided With Anchoring Socket.A ) 3 Step Standard Ladder With Anti-Skid Steps 142 B ) 4 Step Standard Ladder With Anti-Skid Steps 143 Underwater Led Lights Supply, Instalation, Testing & Commissioning Of 12Volt 54 W Under Water Stainless Steel 316L Led Light Fixture ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord. 144 Power Supply Supply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 145 Deck Box Supply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 146 Cleaning Accessories A ) Extensivetelescopic Handle, ( 2.4 - 4.8 ) Metres Long &1.1Mm Thick For Cleaning Attachment In Anodized Almunium. 147 B ) Transparent Blue Polyethylene Hose 40Mm ( 1-1 / 2 ) Dia 30 M Length. 148 C ) Surface Net Skimmer Made In Polypropylne 149 D ) Deep Bag Net Skimmer Made In Polypropylne 150 E ) Curved Polybristle Wall Brush 450 Mm 151 F ) Test Kit For Ph And Chlorine. 152 G ) Hi-Grade Stainless Steel Algae Brush - 10 153 H ) Vacuum Head With Ss-Body, 1 1 / 2 Connection Size 900 Mm Long 154 I ) Deluxe Large Vacuum Head With 4 Wheels, Alu-Body, Plastic Handle, 1 1 / 2 Connection Size 445X130 Mm 155 J ) Polybristle Wall Brush 10 ( 26Cm ) 156 K ) Chemical Tcca 90 ( 50 Kg. ) & Alum ( 30 Kg. ) 157 L ) Nylon Rope 158 Upvc Pipesproviding And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 159 B ) 50 Mm Dia 160 C ) 63 Mm Dia 161 D ) 75 Mm Dia 162 E ) 90 Mm Dia 163 F ) 110 Mm Dia 164 G ) 160 Mm Dia 165 H ) 200 Mm Dia 166 I ) 250 Mm Dia 167 Ball Valveproviding And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia 168 40Mm Dia ( Rate Only ) 169 50Mm Dia ( Rate Only ) 170 63Mm Dia 171 75Mm Dia ( Rate Only ) 172 90Mm Dia ( Rate Only ) 173 Butterfly Valve Providing And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required. A ) 90 Mm Dia 174 B ) 110 Mm Dia 175 C ) 160 Mm Dia 176 D ) 200 Mm Dia 177 E ) 250 Mm Dia 178 Non Return Valveproviding And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 50Mm Dia 179 B ) 63Mm Dia 180 C ) 75Mm Dia 181 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes.A ) 75Mm Dia 182 B ) 90 Mm Dia 183 C ) 110 Mm Dia 184 D ) 160 Mm Dia 185 E ) 200 Mm Dia 186 F ) 250 Mm Dia 187 Puddles Sleevesupply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia 188 C ) 50 Mm Dia 189 D ) 63 Mm Dia 190 E ) 75 Mm Dia 191 F ) 90 Mm Dia 192 G ) 110 Mm Dia 193 H ) 160 Mm Dia 194 I ) 200 Mm Dia 195 J ) 250 Mm Dia 196 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 300Mm Dia Pump Suction Header With 2 Nos 200Mm Dia Flange Connection For Balancing Tank To Pump Suction Header, 1 No. 90 Mm Dia Flange Connection For Vacuum Pipe & 1 No. 200 Mm Dia Flange Connection For Pool Drain Pipe & 4No. 200Mm Dia & 2 No. 160Mm Diaflange Connection For Pump Suction. 197 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 198 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 199 C ) 4 X 6 Sq.Mm ( Rate Only ) 200 D ) 4 X 4 Sq.Mm ( Rate Only ) 201 E ) 4 X 2.5 Sq.Mm 202 F ) 4 X 1.5 Sq.Mm ( Rate Only ) 203 G ) 3 X 6 Sq.Mm ( Rate Only ) 204 H ) 3 X 4 Sq.Mm 205 I ) 3 X 2.5 Sq.Mm ( Rate Only ) 206 J ) 3 X 1.5 Sq.Mm ( Rate Only ) 207 K ) 2 X 6 Sq.Mm 208 L ) 2 X 4 Sq.Mm ( Rate Only ) 209 M ) 2 X 2.5 Sq.Mm 210 N ) 2 X 1.5 Sq.Mm 211 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In 6 Gauge Gi Wire Recess For Loop Earthing As Required. 212 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. A ) 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 213 B ) 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 214 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 215 Electrical Control Panel Supply, Installation, Testing And Commissioning Of Following Swimming Pool Panel 415 V, 1 / 3 Phase And 50 Hz Power Distribution System. Thepanel Shall Be Free Standing Floor Mounting Sheet Metal Enclosed Dust And Vermin Proof Confirming To Ip-54, Compartmentalized Design Fabricated Out Of 16 Swg Sheet Steel, Painting Earthing Numbering, Danger Plate As Per Specifications And Drawings. Flush Front With Aluminium Busbars, Seperate Earth Bus Bars To Be Provided Throughout The Length Of The Panel The Incoming And Outgoing Feeder Breakers, Fuses, Indicating Lamps Etc Shall Be Accomadated In A Modular Multilier Arrangement. The Panel Shall Be Powder Coated Through 9 Tank Process. Adequate Size Cable Alley Shall Be Provided Forcable Termination.The Outgoing Feeders Inside Shall Be Connected Through Bus Bars / Flexible Cable Links. Incoming: One ( 1 ) No. 200A Tp 25 Ka Mccb With Thermomagnetic Digital Flush Mounted 0-200A Ammeter With 3 Way And Off Selection Switch With 3 Nos. 200 / 5 Amp Ct. 1 Set ( 3 Nos. ) Of Phase Indication Lamps 200A 25 Ka Tpn Aluminium Bus Bar. It Shall Be Insulated With Heat Shrinkable Sleeves And Shall Be Color Coded. Outgoing: Recirculation Pumpsix ( 6 ) Nos. Star Delta Starter Complete With Separate Single Phasing Protection Feature. On / Off Indicating Lamps, Relay, Contractors, Start / Stop Push Button, Auto / Manual Selector Switch, Sufficient Nos Of Potential Free Spare Contacts, Etc For Suitable Hp3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Chemical Dosing3 Nos. Toggle Switch For Doser3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Uv 3 Nos. Toggle Switch For Uv 1 Nos.16Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Underwater Lights 1 Nos. Toggle Switch For Led Pool Lightstotal C / O To Summary 216 Entry Water Bodypressure Sand Filtersupply, Instalation, Testing & Commissioning Of Bobbin Wound Top Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Non Corrosive Material, Complete With 6-Way 2 Multiport Valve With Filter Connection / Inter-Connecting Piping, Pressure Gauge, Water Drain / Empty Drain For Filter.Including Corse & Fine Sand Media For Filter As Per Approved Calculation Capacity15000 Ltrs / Hr Design @35000Ltrs / Sqm / Hr. Diameter750 Mm 217 Filter Re-Circulation Pumpsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Plastic Body, In Built Strainer Basket, Impeller In Ppo, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic / Graphite And Steatite, Motor Housing In Aluminium, Withmotor -2800Rpm, F Class Insulation, Protection Ip-55. ( 1W+1S ) Capacity15000 Ltrs / Hr Head 12 Mtrhp 2.0, Three Phase 218 Fountain Re-Circulation Pump Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp7.5, Three Phase 219 Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp2.0, Single Phase 220 Swimming Pool U.V. Sterlizer Supply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 20000 Ltr / Hrworking Pressure = 2.5 Kg / Sqmuv Lamp Wattage = 40 W 221 Chlorine Tablet Feedersupply, Instalation, Testing & Commissioning Of Chlorine Tablet Feeder With Accessories Capacity = 4.5 Kg 222 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 200X200 Mm 223 Fountain Nozzlesupply, Instalation, Testing & Commissioning Of Brass Crome Plated Gyserjet Nozzle With 1 Connection With Required Accessories. 224 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 225 Supply Of12volt 12W Under Water Stainless Steel 316 Ring Underwater Led Lightstype Led Warm White Light ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord.For Fountain Nozzle 226 Power Supplysupply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 227 Supply, Instalation, Testing & Commissioning Ofrgb Programmer For Led Lights. 228 Deck Boxsupply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 229 Upvc Pipes Providing And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 230 50 Mm Dia 231 63 Mm Dia 232 75 Mm Dia 233 90 Mm Dia 234 110 Mm Dia 235 160 Mm Dia ( Rate Only ) 236 200 Mm Dia ( Rate Only ) 237 Ball Valve Providing And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Ball Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia ( Rate Only ) 238 40Mm Dia ( Rate Only ) 239 50Mm Dia 240 63Mm Dia 241 75Mm Dia 242 90Mm Dia ( Rate Only ) 243 Butterfly Valveproviding And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required.A ) 90 Mm Dia ( Rate Only ) 244 110Mm Dia 245 160 Mm Dia ( Rate Only ) 246 200 Mm Dia ( Rate Only ) 247 Non Return Valve Providing And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required. 50Mm Dia ( Rate Only ) 248 63Mm Dia 249 75Mm Dia 250 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes. A ) 75Mm Dia ( Rate Only ) 251 90 Mm Dia 252 110 Mm Dia 253 Puddles Sleeve Supply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia ( Rate Only ) 254 50Mm Dia ( Rate Only ) 255 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 256 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 257 4 X 2.5 Sq.Mm 258 3 X 4 Sq.Mm 259 2 X 6 Sq.Mm 260 2 X 4 Sq.Mm ( Rate Only ) 261 2 X 1.5 Sq.Mm 262 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 263 Electrical Control Panelsupply, Installation, Testing And Commissioning Of 415 V, 1 / 3 Phase And 50 Hz Motor. The Switchboard Cubical Indoor Type Made Of 16 Swg Crca Sheet Painted With Powder Coated Paint Of Siemens Grey Shade. The Cubical Is Wall Mounted With Dust & Vermin Proof Construction With Inter Connection. It Comprise With The Following:A ) One Incoming Mains Of 63 Amps. Mccb – Tp, Schneider B ) One No. 0 – 600 V Digital Voltmeter, Mecon Make 96 Sq.Mm With Voltage Selector Switch. Make. C ) Three Phase Led Type Indicating Lights For Incoming Mains. D ) One No. Ct Operated 0 – 60 / 5 A Digital Ammeter, Mecon E ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light F ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light G ) Four No. Auto / Manual Selector Switches, Salzer Make H ) One No. Mcb Dp 6 Amps. For U / V System, Schneider Make. I ) One No. Toggle Switch For U / V System, Hsd Make. J ) One No. Mcb Sp 6 Amps. For Smps Dc Power Supply For Led Light, Schneider Make. K ) One No. Toggle Switch For Led Pool Lights, Hsd Make.Total C / O To Summary 264 Pond Aerationsupply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 1-3 Hp The Aerator Shall Be A Floating 265 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 5-7.5 Hp The Aerator Shall Be A Floating 266 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 267 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights Ss Frame And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 268 Miscellaneous Item ( Hanging Wire Etc ) Total C / O To Summary 269 Golf Course Water Bodies / Ponds Stpwater Supply:Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : A ) 25 To 40 Mm Nominal Bore 270 B ) 50 To 80 Mm Nominal Bore 271 Fixing Water Meter And Stop Cock In G.I. Pipe Line Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( Cost Of Water Meter And Stop Cock To Be Paid Separately ) . 272 Brass Fittings Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore 273 B ) 20 Mm Nominal Bore 274 C ) 32 Mm Nominal Bore. 275 D ) 40 Mm Nominal Bore 276 E ) 50 Mm Nominal Bore 277 F ) 65 Mm Nominal Bore 278 G ) 80 Mm Nominal Bore 279 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : A ) 15 Mm Nominal Bore 280 B ) 20 Mm Nominal Bore 281 C ) 25 Mm Nominal Bore 282 Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore Horizontal 283 Vertical 284 B ) 32 Mm Nominal Borehorizontal 285 Vertical 286 C ) 40 Mm Nominal Bore Horizontal 287 Vertical 288 D ) 50 Mm Nominal Bore Horizontal 289 Vertical 290 E ) 65 Mm Nominal Bore Horizontal 291 Vertical 292 F ) 80 Mm Nominal Borehorizontal 293 Vertical 294 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 295 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 296 25 Mm Nominal Bore 297 C.I. / Ductile Iron Pipes & Specialsproviding And Laying S&S C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc. ( Heavy Class ) : A ) Up To 300 Mm Dia 298 B ) Over 300 Mm Dia 299 Providing And Laying Flanged C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc., Suitable For Flanged Jointing As Per Is : 1538 :A ) Up To 300 Mm Dia 300 B ) Over 300 Mm Dia 301 Providing And Laying S&S Centrifugally Cast ( Spun ) Iron Pipes ( Class La ) Conforming To Is - 1536 :A ) 100 Mm Dia Pipe 302 B ) 125 Mm Dia Pipe 303 C ) 150 Mm Dia Pipe 304 D ) 200 Mm Dia Pipe 305 E ) 250 Mm Dia Pipe 306 Providing Lead Caulked Joints To Spun Iron Or C.I. Pipes And Specials, Including Testing Of Joints But Excluding The Cost Of Pig Lead : A ) 100 Mm Diameter Pipe 307 B ) 125 Mm Diameter Pipe 308 C ) 150 Mm Diameter Pipe 309 D ) 200 Mm Diameter Pipe 310 E ) 250 Mm Diameter Pipe 311 Providing Flanged Joints To Double Flanged C.I. / D.I. Pipes And Specials, Including Testing Of Joints : A ) 100 Mm Diameter Pipe 312 B ) 125 Mm Diameter Pipe 313 C ) 150 Mm Diameter Pipe 314 D ) 200 Mm Diameter Pipe 315 E ) 250 Mm Diameter Pipe 316 C.I. Sluice Valves / Fire Hydrants & Fixturesproviding And Fixing C.I. Sluice Valves ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :A ) 100 Mm Diameterclass I 317 Class Ii 318 B ) 150 Mm Diameter Class I 319 Class Ii 320 200 Mm Diameter Class I 321 Class Ii 322 250 Mm Diameterclass I 323 Class Ii 324 300 Mm Diameter Class I 325 Class Ii 326 Constructing Masonry Chamber 60X60x75 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 327 Constructing Masonry Chamber 90X90x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 328 Constructing Masonry Chamber 120X120x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 329 Constructing Masonry Chamber 60X60x75 Cm, Inside In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Fire Hydrants, With C.I. Surface Box 350X350 Mm Top And 165 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand:10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 330 Air Valve & Water Meter ( Bulk Type ) : Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :50 Mm Dia 331 80 Mm Dia 332 100 Mm Dia 333 Providing And Fixing Enclosed Type Water Meter ( Bulk Type ) Conforming To Is : 2373 And Tested By Municipal Board Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :150 Mm Dia Nominal Bore 334 200 Mm Dia Nominal Bore 335 Providing And Fixing C.I. Dirt Box Strainer For Bulk Type Water Meter With Nuts, Bolts, Rubber Insertions Etc. Complete Conforming To Is : 2373 :80 Mm Dia 336 100 Mm Dia 337 150 Mm Dia 338 200 Mm Dia 339 Providingandlayings&Sc.I.Standardspecialssuitablefor Mechanical Jointing As Per Is : 13382 :Up To 300 Mm Dia 340 Filter Feedpump :Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty: A ) .No. Ofpumps: 3 ( 2 Working + 1 Standby ) B ) .Capacity :2000 Lpmc ) .Head :35 Md ) .Capacity :2000 Lpm E ) .Hp ( Motors ) : 75 Hp 341 Pressure Filter ( Domestic Water ) :Providing And Fixing Vertical Dual Media Pressure Filter ( Comprising Of Minimum 300Mm Bed Depth Of Anthracite And Support Media And Minimum Height On Straight 2500Mm ) Fabricated From High Performance M.S Plate Of Minimum 10Mm Thick For Shell & 12Mm Thickfor Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Internally Treated With Coal-Tar Epoxy, Complete With Air Scouring, Collection System Complete With Initial Charge Of Media, M.S Facepiping, Valves, Accessories, External Painting With 2 Coats Of Red Oxide Primer And Enamel Paint, Testing And Commissioning Complete. ( Tested To 5.0 Kg / M2 ) A ) .Discharge : App.120000 Lph ( Each ) B ) .Filtration Rate : 24, 500 Lit. / M2 / H C ) .Each Suggested Dia App.:As Per Manifacture Detail 342 Water Softener:Providing And Fixing ‘Cation’ Ion Exchange Water Softener Fabricated From Minimum 10Mm Thick M.S. Plateon Min. Shell And 12Mm Thick M.S. Plate On Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Complete With Initial Charge Of Filter Media And Ion Exchange Resins, Face Piping Accessories, Diaphragm Valves Of Approved Specifications, Hdpe Brine Tank Of Min. 500 Liters, Piping Testing And Commissioning Complete With Resins Of Approved Quality And Make And Regeneration Assembly Complete With Valves, Ejector, Brine Suction Valves And Piping. ( Bidder Must Indicate Type And Quantity Of Resin Used And Quantity Of Salt Required Per Regeneration ) . All Internal Parts Of The Softener Shall Be Rubber Lined As Per Approved Specifications.A ) .Minimum Expected Rate Of Flow:App.32, 000 Lph B ) .Total Soft Water To Be Produced Between Two Regenerations: App. 256 Cu.M C ) .Expected Raw Water Hardness : App. 450-500 Ppmd ) .Expected Treated Water Hardness: Less Than 5 Ppm ( Zero Commercial Hardness ) E ) .Max. Working Pressure: 4 Kg / Cm2 343 Cubical Panel Board - Plumbing : Supply, Installation, Testing And Commissioning Of Cubical Type Sectionalised Floor Standing Switch Board Of 31 Mva Fault Capacity At 415 V Complete With 3.5 Strip, 160 A Capacity Aluminium Bus - Bar Electrolytic Grade, Cable Alley, Switchgears Of Following Capacity & As Per Specifications.Incomer : 600 A Tp Mccb With Heavy Duty Solid Neutral Link With ( 0-100A ) Ammeter With 3 Ct And Selector Switch, ( 0 - 500 V ) Voltmeter With Selector Switch, Phase Indication Light Withprotection Fuse. - 01 Setoutgoings : I ) For 5 X 75 Hp Domestic Water Fixed Speed Hydroneumatic Pumps ( 1 Duty + 1 Stand By ) Ii ) For 2 X 5 Hp Sump Pump ( 1 Duty + 1 Stand By ) 150 A Tp Mcb With 40 A Dol Starter, Overload Relay, 96 Mm ( 0-40A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01Set. 40A Tp Mcb With 25 A Dol Starter, Overload Relay, 96 Mm ( 0-25A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01 Set.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
TenderDetail
Loading tenders