View Bid Results For Environmental Service Tenders

We found 1310 Bid Results related to environmental service tenders. You can find Contractor details who won environmental service tenders along with contract details in Bid awards announcements section.

Filters
Stage
1156
92
62
Tender Publishing Platform
769
541
State / UT
36
132
117
87
81
73
72
70
68
59
45
43
43
42
41
38
38
33
33
30
29
29
27
15
14
10
9
8
5
5
4
3
2
2
1
1
1
Contract Value
284
353
476
195
Publish Date
1
0
0
0
0
Sector
28
309
218
138
138
79
72
64
51
37
31
24
22
21
19
15
12
9
7
7
7
6
6
4
4
4
3
2
1
Ownership
7
447
429
370
55
6
2
1
Within keyword
Active filters:
Showing 1–27 of 1310 tenders matching your filters
Contract Date: Ref. Documents Contract Value : 51.65 Lakh
Boards / Undertakings / PSU No of Bidders 12
Contract Date: Ref. Documents Contract Value : 1.96 Lakh
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : 28.12 Lakh
Boards / Undertakings / PSU No of Bidders 16
7.
Public Administrative Department #11379212 AOC
Supply & Installation Of Gym Equipments For Establishing An Open Gym At Seetharama Colony In W.No. 7- Chilkanagar Uppal Circle Ghmc. ( 4Th Call ) -2.00 Supply, Delivery And Installation Of Air Swing With Carrying Capacity Of 2 Persons Of Overall Sizes 1000 X 890 X 1300 Mm Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 25Mmnb & 40Mm Nb, 50Mm Nb And 80 X 40 Mm Rectangular Tube With Standing Base Size Of 250Mm Round Size Fixed With Deep Grooveé Self Aligning Ball Bearings Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 44443.00 ( Item Price ) + Rs. 907.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 2.00 Supply, Delivery And Installation Of Air Walker / Sky Walker With Carrying Capacity Of 1 Person Of Overall Sizes 1100 X 550 X 1300 Mm Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 25Mmnb& 40Mm Nb, 50Mm Nb And 60 X 40 Mm Rectangular Tube With Standing Base Size Of 320 X 135 Mm Fixed With Deep Grooveé Self Aligning Ball Bearings & Thrust Bearings Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 45227.00 ( Item Price ) + Rs. 923.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 1.00 Supply, Delivery And Installation Of Big Arm Wheel With Using Capacity Of 2 Person Of Overall Sizes 850 X 750 X 1920 Mm Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 25Mmnb & 50Mm Nb , Handle Bars Madeup Of High Quality Grip Rubber Fixed With Deep Grooveé Self Aligning Ball Bearings & Thrust Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 58359.00 ( Item Price ) + Rs. 1191.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 1.00 Supply, Delivery And Installation Of Elliptical Machine With Carrying Capacity Of 1 Person Of Overall Sizes 1050 X 650 X 1400 Mm Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 40Mm Nb, 60 X 40 Mm.Handle Bars Madeup Of High Quality Grip Rubber Fixed With Deep Grooveé Self Aligning Ball Bearings & Thrust Bearings Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 46697.00 ( Item Price ) + Rs. 953.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 2.00 Supply & Installation Of Rowing Machine / Rower.Technical Specification: Double Equipment 1. Dimensions ( Lxwxh ) : 1250 X 800 X 1150 Mm 2. Fabricated With Main Post Of Nb 100Mm ( G.I. ) ‘C’ Class Pipe Of Approved Make. 3. Main Frame Of Nb 65Mm ( G.I. ) ‘C’ Class Pipe. 4. Handle Support Frame Of Nb 25Mm ( G.I. ) ‘C’ Class Pipe. ( ‘Nb’ Stands For Nominal Bore Size I.E., Internal Diameter Of Pipe In Millimeters ) . 5. All Pipes Are Powder Coated With 80-120 Micron Thick Akzonobel Or Equivalent Paints. 6. All Joints Of Pipe Are Robotic Welded With Joints Scalloped As Necessary And Dressed Off Removing Sharp Edges And Burrs. 7. Zinc Primer Paint Is Applied At All The Welding Points Prior To Finishing. 8. Base Plate Cover Made Of Virgin Lldpe Plastic By Rotational Molding With 4.00Mm Thickness, Uv Resistant And Colored. 9. Foothold Made Of Nb 50Mm ( G.I. ) ‘C’ Class Pipe. 10. Seat To Be Made Up From Virgin Lldpe Manufactured By Rotational Molding With 4.00 Mm Thickness, Colored, Uv Resistant And Environmental Friendly. 11. Maintenance Free Bearings Of Skf Or Equivalent Make Duly Oil Sealed And Self-Lubricated Are Used In The Equipment Manufactured. 12. The Equipment Are Fitted With Inbuilt Limiters To Prevent Unwanted Movements. 13. The Equipment Is Fixed On Ground With Concrete Of Minimum Strength M-25 And J Shaped Welded Bolts Of 18Mm Thickness. 14. Once The Concrete Is Set, The Equipment Is Fixed On To It And Nuts And Bolts Are Covered With Base Plate Cover. 15. High Tensile Steel With Galvanized Nut Bolts Are Used For Assembly. 16. Equipment Made To En16630 & Din 79000 International Standard For Outdoor Fitness Equipment. 17. Self-Explanatory Stainless Steel Label Fixed On Equipment For Ease Of Use. ( The Total Unit Cost Is = Rs. 41639.00 ( Item Price ) + Rs. 851.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 2.00 Supply, Delivery And Installation Of 3-Person Waist Trainer ( Standing Twister ) With Carrying Capacity Of 3 Persons Of Overall Sizes 1450 X 1450 X 1350 Mm With Standing Base Of 300 Mm Dia Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 25Nb & 40Mm Nb. Fixed Wheel Of 550 Mm Dia Having Standing Positions Equally Spaced At 120 Degrees Each Fixed With Deep Grooveé Self Aligning Ball Bearings & Thrust Bearings Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 55615.00 ( Item Price ) + Rs. 1135.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 1.00 Supply, Delivery And Installation Of Leg Press With Carrying Capacity Of 2 Persons Of Overall Sizes 2000 X 380 X 1650 Mm With Seat Size Of 300 X 300 Mm Dia Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 25Nb & 40Mm Nb. Fixed With Deep Grooveé Self Aligning Ball Bearings With Handle Bars Madeup Of High Quality Grip Rubber And Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 59976.00 ( Item Price ) + Rs. 1224.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 1.00 Supply & Installation Of 3-Person Waist Trainer ( Sitting Twister ) . With Carrying Capacity Of 3 Persons Of Overall Sizes 1500 X 1500 X 1350 Mm With Standing Base Of 350 Mm Dia Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 25Nb & 40Mm Nb. Fixed Wheel Of 550 Mm Dia Having Standing Positions Equally Spaced At Each Fixed With Deep Grooveé Self Aligning Ball Bearings & Thrust Bearings Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 60564.00 ( Item Price ) + Rs. 1236.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 1.00 Supply, Delivery And Installation Of Double Cross Walker / Arm Strengthener With Carrying Capacity Of 2 Persons Of Overall Sizes 1100 X 915 X 1430 Mm Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 80Mm Nb & 60 X 40 Mm Rectangular Tube Fixed With Deep Grooveé Self Aligning Ball Bearings And Handle Bars Madeup Of High Quality Grip Rubber Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 71393.00 ( Item Price ) + Rs. 1457.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 1.00 Supply, Delivery And Installation Of Taichi Spinner ( 4 ) Wheel With Using Capacity Of 2 Person Of Overall Sizes 1050 X 1000 X 1350 Mm Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 50Mm Nb , Handle Bars Madeup Of High Quality Grip Rubber Fixed With Deep Grooveé Self Aligning Ball Bearings Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 43855.00 ( Item Price ) + Rs. 895.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 1.00 Supply, Delivery And Installation Of Shoulder Press With Carrying Capacity Of 2 Persons Of Overall Sizes 1800 X 700 X 1900 Mm With Seat Size Of 300 X 300 Mm Dia Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 25Nb &32 Mm Nb , 60 X 40Mm Nb Rectangular Tube Fixed With Deep Grooveé Self Aligning Ball Bearings And Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 67081.00 ( Item Price ) + Rs. 1369.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 1.00 Supply, Delivery And Installation Of Chest Press With Carrying Capacity Of 2 Persons Of Overall Sizes 1800 X 700 X 1900 Mm With Seat Size Of 300 X 300 Mm Dia Made Of Hot Dipped Galvanized Pipes Confirming To Is 1239 ( Part-1 ) With Gi Thickness 60 Micron Materials And Heavy Duty ( C Class ) Series Of Pipes Only.Equipment Should Be Made Up Of 100 Nb Main Post Pipe With Supporting Structure 25Nb &32 Mm Nb , 60 X 40Mm Nb Rectangular Tube Fixed With Deep Grooveé Self Aligning Ball Bearings And Using Hard Ware Of Grade 4.60 Galvanized.The Painting To The Equipment Should Be Powder Coated ( 80-100 Microns Thickness.All Open End Pipes Should Be Covered With Ss / Lldpe Caps & The Equipment Is Grouted With M18 Foundation Bolts With Concrete Strength Of M25 For Safety And Stability And As Directed By The Engineer-In-Charge. ( The Total Unit Cost Is = Rs. 68257.00 ( Item Price ) + Rs. 1393.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 1.00 Supply, Delivery And Installation Of Leg Curl : Technical Specification: 1. Dimensions ( Lxwxh ) : 1500 X 450 X 650Mm. 2. Fabricated With Main Post Of Nb 100Mm ( G.I. ) ‘C’ Class Pipe Of Approved Make. 3. Leg Support Frame Of Nb 65Mm And All Other Pipes Of Nb 32Mm ( G.I. ) ‘C’ Class Pipe. 4. All Pipes Are Powder Coated With 80-120 Micron Thick Akzonobel Or Equivalent Paints. 5. All Joints Of Pipe Are Robotic Welded With Joints Scalloped As Necessary And Dressed Off Removing Sharp Edges And Burrs. 6. Zinc Primer Paint Is Applied At All The Welding Points Prior To Finishing. 7. Base Plate Cover And All Open End Pipes Covered By Ss / Lldpe Caps. 8. Maintenance Free Bearings Of Skf Or Equivalent Make Duly Oil Sealed And Self-Lubricated Are Used In The Equipment Manufactured. 9. The Equipment Are Fitted With Inbuilt Limiters To Prevent Unwanted Movements. 10. The Equipment Is Fixed On Ground With Concrete Of Minimum Strength M-25 And J Shaped Welded Bolts Of 18Mm Thickness. 11. Once The Concrete Is Set, The Equipment Is Fixed On To It And Nuts And Bolts Are Covered With Base Plate Cover. 12. High Tensile Steel With Galvanized Nut Bolts Are Used For Assembly. 13. Equipment Made To En16630 & Din 79000 International Standard For Outdoor Fitness Equipment. 14. Self-Explanatory Stainless Steel Label Fixed On Equipment For Ease Of Use. ( The Total Unit Cost Is = Rs. 40719.00 ( Item Price ) + Rs. 831.00 For Inland Transportation, Insurance And Other Services Required To Convey The Goods To The Final Destination But Excluding Gst For Complete Item Of Work. 16.00 Earth Work Excavation For Foundation For Cloumns Including Laying Of Plain Cement Concrtete 1:5:10 Grade Including Cost Of Vibration With Pin Vibrators And Laying Of Rcc Cement Concrete 1:2:4 For Columns Including Cost Of Hysd Steel Bars , Centering And Shuttering Including Labour Cahrges And Curing For A Period Of 21- Days For Complete Item Of Work As Directed By The Engineer-In-Charge. 1.00 Providing Of Sbr Rubber Tile Flooring For An Area Of 100 Sq.M Including Earth Work Excavation , Levelling Of Surface And Compaction, Laying Of Palin Cement Concrtete 1:5:10 Grade For Bed Including Cost Of Centering And Shuttering Vibration With Plate Vibrators All Work Upto Plinth Level Of 100Mm Thick Layer And Cement Concrete Flooring 1:2:4 Finished With Floating Coat Of Neat Cement Including Cement Slurry, Including The Cost Of Nosing Of Steps Etc, Of 75Mm Thick Layer And Curing To Slabs For A Period Of 21- Days For Complete Item Of Work As Directed By The Engineer-In-Charge. 1.00 Providing , Fabricating And Fixing One Instructional Sign Iinformation Sign Board ) As Specified In Cement Concrete Block Foundation At Each Location Including Cost Of Materials And Labour , Taxes For Complete Item Of Work As Directed By The Engineer-In-Charge. 13.00 Providing Annual Maintenance And Repair Of The Supplied Goods For A Period Provided That This Service Shall Not Relieve The Supplier Of Any Warranty Obligations Under This Contract. 13.00 Providing Of Detailed Operations And Miantenance Manual For Each Appropriate Unit Of Supplied Goods.
Contract Date: Ref. Documents Contract Value : 14.87 Lakh
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 64.50 Lakh
Government Departments No of Bidders 11
Contract Date: Jun 24, 2026 Contract Value : 5.06 Lakh
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 8.46 Lakh
Boards / Undertakings / PSU No of Bidders 9
Uttarakhand View Result →
Contract Date: Ref. Documents Contract Value : 13.74 Lakh
Boards / Undertakings / PSU No of Bidders 19
Maharashtra View Result →
18.
Power #11260009 Technical Bid
Tender for Supply Of Various Connectors & Junction Box For 2X500 Mw, Dtps, Anpara. , Supply Of Various Connectors & Junction Box For 2X500 Mw, Dtps, Anpara. , Straight Connector For Oil Level Switch, Angle: Straight Degree(S), Application: True Mil, Class: F, Colour: Black, Contact Configuration:7#16, Contact Plating: Silver, Contact Size:16 Awg, Contact Type: Socket, Contact Gender: Socket (Female), Contact Material: Copper Alloy, Current Rating: 13 A, Dielectric Material: Neoprene, Housing Finish: Olive Drab Cadmium, Housing Material: Aluminium Alloy, Housing Type: Metal, Insert Arrangement: 16S-1, Mating Type: Threaded, Mil Type: Mil-Dtl-5015, Mounting Type: Free Hanging (In-Line), Number Of Contacts: 7,Primary Type: Mil/Aero, Series: Ms 5015 Series, Shell Size:16S, Special Features: Environmental Resistant, Single Key/Keyway Shell, Polarization, Termination: Solder, Type: 5015 Mil Spec, Voltage Rating: 700 V ; Wire Size: 16 Awg. , Circular Connector For Sensor. Mil-Dtl-5015 Series, Shell Style: Straight Plug, No. Of Contacts: 2 Contacts, Contact Gender: Socket (Female), Termination Style: Solder, Circular Contact Type: Solder Socket, Mounting Style: Free Hanging, Contact Plating: Silver, Contact Material: Copper Alloy, Mating Style: Bayonet, Mounting Angle: Straight, Shell Material: Aluminium Alloy, Voltage Rating: 700 V, Current Rating: 13 A, Coupling Style: Threaded, Insert Arrangement: 10Sl-4, Connector Body Material: Aluminium Alloy Body, Connector Body Plating: Olive Drab Chromate Over Cadmium, Contact Plating: Silver, Wire Gauge: 22 Awg To 16 Awg, Insert Rotation: N, Service Class: Environmentally Sealed, Cable Opening: 0.281 (7.14Mm). , Polystyrene Thermoplastic Cable Junction Box; Material: Polystyrene, Ip Rating: Ip 65, Dimensions: 139X119x70mm, Weight: 0.23 Kg, Ambient Temperature: -25 To 40 Degree C, Mounting Width:114 Mm, Installation Depth=52 Mm. , Feed-Through Terminal Block With Installed End Clamps & Din Rail, Nom. Voltage: 800 V, Nominal Current
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
20.
Housing Urban and Rular Development #11223251 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical &-Hospital Division , Jammu Supply, Installation, Testing & Commissioning Of Medical Grade Online Double Pass Reverse Osmosis(Ro) Plant Of 500 Lph Capacity For Dialysis Along With Allied Works On Turnkey Basis At Sdh Jagti Mhdj/E-Nit 10 Of 2026-27 Dated: 20.04.2026 Due : 29.04.2026 Name Of The Bidder/ Bidding Firm / Company : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. 0.0 Item Code / Make Quantity Units Estimated Rate In Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Rates Inclusive All Taxes Excise Duty Gst Rs. P Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Total Amount Without Taxes In Rs. P Total Amount With Taxes Total Amount In Words , Medical Grade Double Pass Reverse Osmosis System Of 500 Litre Per Hour Capacity For Dialysis Unit, Along With Allied Works In Sub District Hospital Jagti, Jammu On Turnkey Basis. Complete Job As Per Site Condition In All Respect (A Turnkey Job) As Per Technical Specifications/Scope Of Work Mentioned In E-Nit At Serial No. 1 , Provided And Fixing Of Civil & Structural Works-Rooftop Shed (15Ft X 12Ft) The Civil Works Will Comprise Design, Fabrication, And Execution Of A Structurally Sound Rooftop Shed Engineered To Withstand Environmental Loads And Ensure Long-Term Service Life. Job Includes Providing And Fixing Of Elevated Reinforced Cement Concrete Base Slab: Height: 6 To 8 Inches (150-200 Mm) Above Rooftop Level. Material: M25 Grade Reinforced Cement Concrete (Rcc) With Fe-500 Tmt Bars, Conforming To Is 456:2000.Slope: 1:100 Slope Towards Drainage Points For Effective Water Runoff. Drainage System: 4-Inch Diameter Pvc Pipes (Reputed Brand), Integrated With The BuildingS Rainwater Disposal Network. Boundary Walls Construction: 230 Mm Thick Brickwork (Masonry Parapet Walls) On All Four Sides, Fixed At 2 Feet (600 Mm) Height. Plaster: Interior: Cement Mortar Plaster (1:4 Ratio) With Waterproofing Additives Exterior: Cement Mortar Plaster (1:4 Ratio) With Waterproofing Additives. Tiling Interior: 100% Vitrified Tiles (Is-Compliant) With 100 Mm High Skirting. Roofing & Cladding Material: Color-Coated Corrugated Galvanized Iron (Cgi) Sheets, 0.40 Mm Thick, For Both Roofing And Wall Cladding. Support Structure: Mild Steel (Ms) Angle Posts (50X50x5 Mm), Conforming To Is 2062 Grade, Finished With Red Oxide Primer And Synthetic Enamel Paint. Fixing: Secured With Galvanized J-Hooks And Epdm Washers. Roof Slope: Cgi Sheets On The Roof Installed With A 1:100 Slope To Align With The Drainage System, Ensuring Proper Water Runoff. All Steel Members Conforming To Is 2062 Grade, Red Oxide Primer + Synthetic Enamel Paint Finish. Secured With Galvanized J-Hooks + Epdm Washers. Access Door 1.2 M (4 Feet) Wide Ms Framed Powder-Coated Door With Heavy-Duty Lock System. Interior Finishing 100% Vitrified Tiles, Reputed Make, Is-Compliant. Skirting Up To 100 Mm Height. Electrical Works • Wiring & Distribution Concealed Wiring With Frlsh Copper Cables As Per Is 694. 10 Sq.Mm Copper Cable Dedicated To Ro Plant. Job Includes Fixtures & Accessories Ceiling Fan, Exhaust Fan, Switchboards, Lighting. 16A & 6A Sockets Of Reputed Make. Double Pole Mcbs For Safety. , Supply, Installation, Testing And Commissioning Of 5Kva Online Ups With In Build Isolation Ups/Inverter System & Stabilizer (If Required) For Power Back Up Of Ro Plant At Dialysis Centre Of Sdh Jagtifor Uninterrupted Power Supply With Maximum Battery Backup Of Load To The System Along With 2-Years Warranty. Description Of Technical Specifications: • Power Backup • 5 Kva Online Ups, Reputed Make, 4-5 Hours Backup. • Directly Connected To Ro Plant. • Range 160 - 280Vac • Pwm Technology & Igbt Based • Pure Sine Wave Output With Thd 3% • Power Factor 0.8 • Large Input Operating Range, Eliminates Unnecessary Battery • D I S C H A R G E • Ups Startup Without Battery • Multi-Functional Lcd/Led Display • In-Built Galvanic Isolation • Automatic Battery Charge In Ups Off Mode • Static Bypass And Cold Start • Emi/Rfi And Noise Filter • Generator And Solar Compatible • Auto-Restart Function • Extended Backup Time Suitable Charger • Protection: Output Short Circuit, Low Voltage Of Battery, Over Or • Lack Of Input Voltage, Overload And So On • Standard: Iec/En62040-1, 62040-2, 62040-3, Complying To Ce, Bis, Rohs, • Iso:9001, Iso:14001 • Battery Rack Total In Figures 0.0 0.0 Inr Zero Only 4.0 Construction Of Chamber For 100Mm Sluice Plates Item5 10.0 Nos Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : 89.36 Lakh
Boards / Undertakings / PSU No of Bidders 14
Andhra Pradesh View Result →
25.
Educational and Research Institute #11191037 AOC
Bids Are Invited For Manpower Outsourcing Services - Fixed Remuneration - Admin; Admin Training And Placement Manager; Post Graduation Mba , Manpower Outsourcing Services - Fixed Remuneration - Teaching; Computer Science Engineering; Post Graduation Me Or Mtech , Manpower Outsourcing Services - Fixed Remuneration - Admin; Admin Officer; Post Graduate , Manpower Outsourcing Services - Fixed Remuneration - Technical; Associate Engineer Electrical; Diploma , Manpower Outsourcing Services - Fixed Remuneration - Gym Instructor; Gym Instructor; Bped , Manpower Outsourcing Services - Fixed Remuneration - It- Technical; Tda Or It Engineer Or Maintenance; Graduate Or Post Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Msc; Post Graduate , Manpower Outsourcing Services - Fixed Remuneration - Admin; Data Entry Operator And Typist; High School Or Secondary School , Manpower Outsourcing Services - Fixed Remuneration - It-Technical; Diploma Or Graduation In Civil Engineering; Diploma Or Graduation In Civil Engineering , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Diploma Or Graduation In Civil Engineering , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Quality Engineer; Graduation Or Pg In Civil Engineering , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Degree Or Diploma In Civil Engineering , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Mep Engineer; Degree In Mechanical Or Electrical Engg , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Engineering Degree In Civil Engineering Or Diploma In Civil Engineering , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Engineering Degree Or Diploma In Civil Engineering , Manpower Outsourcing Services - Fixed Remuneration - Admin; Stenographer; Graduate , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Be In Civil Engineering , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Mtech Or Phd In Structural Engineering , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Scientific Assistant Or Air Quality Analyst; Msc In Environmental Science Or Chemistry First Class , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Air Quality Monitoring Station Operator; Secondary School , Manpower Outsourcing Services - Fixed Remuneration - Admin; Administrative Operator Or Office Assistant Or Executive Assistant; Graduation In Any Discipline Or Diploma In Computer Application And Mscit Certificate , Manpower Outsourcing Services - Fixed Remuneration - Admin; Administrative Operator Or Office Assistant Or Executive Assistant; Secondary School , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Civil Engineer; Graduate Or Post Graduate Or Phd , Manpower Outsourcing Services - Fixed Remuneration - Non-It Technical; Project Engineer Or Scientist Or Postdoctoral Fellow Or Research Associate; Graduate Or Post Graduate Or Phd , Manpower Outsourcing Services - Fixed Remuneration - Others; Semi Skilled Labour Or Unskilled Supervisory Worker; Middle School , Manpower Outsourcing Services - Fixed Remuneration - Admin; Office Associate; Graduate
Contract Date: Ref. Documents Contract Value : 2.19 Crore
Boards / Undertakings / PSU No of Bidders 274
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 17.51 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 2
Maharashtra View Result →
28.
Defence #11189202 AOC
Bids Are Invited For Pir Insulated Prefab Modular Shelter Of Size 10.46 X 6.10 Mtr Including 1.5M Wide Verandah As Per Brief Technical Specifications , Prefab Single Bunk Size Of 1900 X 900Mm And 500Mm Height , Double Leaf Steel Lockers Of Height 1500Mm X Width 900Mm X Depth 475Mm , Chair Rotating Type With Cushion And Rubber Hand Rest , Steel Table Shall Of 1.20Mx0.76M And Height 0.75M , Non Skid Ceramic Tiles Of Size 300 X 300 X 7Mm , Vitrified Tiles Of Size 600Mm X 600Mm X 10Mm , White Cement In 1 Kg Packet , Puf Insulated Water Tank 1000 Ltrs , Water Staging Platform Made Of Ms Angle , Water Proofing Compound Isi Marked In 1 Kg Packing , Quick Setting Compound , Pvc Pipe 110Mm Dia 6 Mtr Long , Fire Extinguisher A B C Type Portable Net 2 Kg Capactiy Cylindrical , Looking Mirror 1200Mm X 600Mm With 5.5Mm Thick Float Mirror , Looking Mirror 300Mm X 450Mm With 5.5Mm Thick Float Mirror , Pvc Insulated And Pvc Sheathed Multistranded Copper Conductor Industrial Cable 1100 Volts 3 Core 1.0 Sqmm , Pvc Insulated And Sheathed Copper Service Cable 10 Sqmm 2 Core , Pvc Frls Copper Cable 1 Sqmm Single Core With Multistranded Conductor 1100 Volts Grade In Green Colour , Pvc Frls Copper Cable Pvc 2.5 Sqmm S C Multistranded , Pvc Sheathead Frls Copper Cable 1.5 Sqmm Single Core With Multistrand 1100 Volts Grade , Decorative Type Ultra Slim Linear Led Fixture, With Extruded Polycorbonate , Led Securrity Light Energy Saving And Environmental Firendly Long Life Versatile Pressure Die Cast Aluminim Ip 66 , Casing Capping 0.75 Inch Length 10 Feet Size , Pvc Casing Capping Tee 0.75 Inch , Pvc Casing Caping Coupler Of Size 0.75 Inch , Ceiling Rose 2 To 3 Terminal , Switch Piano Type 5 Amps Isi Marked , Switch Socket Combination Mutipurpose 5 Amp 5 Pin With Gang Box , Switch Socket Combination Mutipurpose 5 Amp 3 Pin And 3 Pin 15 Amp With Gang Box , Pvc Elbow 0.75 Inch For Casing Caping , Tape Insulation 10 Mtr , Pvc Switch Board 7 X 4Inch , Pvc Swith Board 6 X 8Inch , Pvc Square Block , Mcb Db Spn 8 Ways Double Door 240 Volts With Aluminium Bus Bar , Mcb 6 Amps Sp 240 Volts , Mcb 16 Amps Single Pole 240 V , Mcb Spn 40 Amps Dp 240 Volts , Exhaust Fan, Havey Duty Ms Body 300Mm Sweep , Bib Tap Cp 15Mm Bore Isi Marked , Stop Cock Cp 15 Mm , Pillar Cock Stainless Steel Cp 15 Mm Bore , Chromium Plated Two Way Bib Tap And Health Faucet With Flexible Pipe And Clamp , Ppr Pipe 20Mm 3 Layer , Ppr Pipe 25Mm 3 Layer , Ppr Tee 20 Mm Dia , Ppr Tee 25 Mm Dia , Ppr Elbow 90 Degree 20 Mm , Ppr Elbow 45 Degree 20 Mm , Ppr Elbow 90 Degree 25 Mm , Ppr Elbow 45 Degree 25Mm , Ppr Socket 20Mm Dia , Pvc Socket 110 Mm , Pvc Elbow 110 Mm Dia , Pvc Tee 110 Mm , Ppr Union 20 Mm , Pvc Float Valve Heavy Duty 25Mm Dia Suitable For Ppr Pipe , Ppr Male Threated Socket 20-25Mm Dia , Ppr Female Threated Socket 20-25Mm Dia , Ppr Male Threated Elbow 20-25Mm Dia , Ppr Reducer Socket 25 X 20Mm , M Seal , Pvc Elbow 2 Inch , Pvc Socket 2 Inch , Pvc Pipe 2 Inch Dia 6 Mtr Long , Pvc Floor Trap 4 Inch Dia With Grating 2 Inch Outlet , Pvc Socket 4 Inch , Pvc Elbow 4 Inch Dia , Pvc Pipe 4Inch Dia 6 Mtr Long , Pvc Grating 4 Inch Dia , Pvc Clip For Ppr Pipe 25Mm Dia , Ppr Tank Connector 25 Mm , Vitreous Wash Hand Basin , Nsss Commodes As Per Technical Specification , Pre-Fabricated Septic Tank Of 1000 Ltrs Capacity Septic Tank , Pre-Fabricated Sokage Pit 500 Ltr Capacity , Pvc P Trap 110 X 75Mm , Pvc Elbow 3 Inch , Pvc Socket 3 Inch , Pvc Pipe 3 Inch Dia 6 Mtr Long , Pvc Tee 3 Inch , Jointing Resin Solution Of 1 Kg Or Capsules Of Silicone Gel With Gel Gun For Leak Proof , Towel Rail Cp 600Mm Long , Soap Dish Stainless Steel Chromium Plated Complete With Fittings , Electric Storage Water Heater Geyser 15 Ltr Capacity , Flexible Connection Pipe 450 Mm Long For Hot And Cold Water. , Lightening Conductors Set Complete With All Accessories , Elect Earthing Complete Set , Ppr Female Threated Elbow 20-15Mm Dia , Ppr Male Threated Socket 20-15Mm Dia , Ppr Female Threated Socket 15-20Mm Dia , Wastebin 120 Ltr Dim Of 480 X 550 , Water Dispencer Of 15 Ltr Capacity , Invertor 2Kva Capacity With 02 Battery 24V , Electrician Tool Kit , Plumbing Tool Kit , Measuring Fibre Glass Tape 5 Mtr Long , Industrial Safety Helmet Conforming To Is-2925 , Showel Square Nose 14 Gauge Blade Size 310 X 245 Mm Shaft Size 710 Mm , Puf Rivet Machine , Galvanised Iron Pan Mortar Tasla 18 Gauge 16Inch Dia Minimum Weight 01 Kg , Rammer Earth With Handle Minimum Weight 5 Kg Without Handle , Electric Tile Cutting Machine With Interchangable Blades , Electrical Sheet Cutter Machine With Blad Total Quantity : 3093
Contract Date: Ref. Documents Contract Value : 27.77 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 7
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 15.20 Lakh
Boards / Undertakings / PSU No of Bidders 10
31.
Tourism #11175186 Price Bid
Tender for Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Kinds Of Soil , Earthwork In Excavation In Trenches For All Leads & Lifts In All Type Of Strata Comprising Of Any Type Of Materials Either In Full Or Part As The Case May Be Adopting Any Method/Methods As May Be Convenient As Permitted Excluding Blasting In All Conditions Such As Dry, Moist, Foul, Saturated, Submerged, Etc,. Including Dressing Of Sides, Planking & Strutting, Timbering ,Ramming Of Bottom ,Pumping And Bailing Out Water ,Barricading Danger Lighting Guarding, Getting Out Excavated Soil & Stacking As Directed By Engineer For All Leads & Lifts Etc. Complete , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer . , Supplying And Filling In Plinth Under Floors, Trenches Including Watering Ramming Consolidating, Dressing, Complete. Moorum , Disposal Of Unserviceable Materials Such As Laterite Stones, Bricks, Cement Concrete, Scrap Materials, Excess Earth By Tipper Truck Or As Directed By Engineer In Charge Including Loading, Transportation, Unloading, Levelling Etc At The Risk And Cost Of Agency / Contractor Including Selection Of Site For Disposal With All Lifts And Leads Etc. All Complete. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: All Work Up To Plinth Level , Providing And Laying In Position Ready Mixed Concrete (Rmc) Manufactured In Fully Automatic Batching Plant And Transported To Site Of Work In Transit Mixer For A Lead Upto 10Kms Having Continious Agitated Mixer, Manufactured As Per Mix Design Of Specified Grade For Reinforced Cement Concrete Work Including Pumping Of R.M.C., From The Transit Mixer To The Site Of Laying, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement Including The Cost Of Admixtures In Recommended Porportions As Per Is : 9103 To Accelerate/Retard Setting Of Concrete, Improve Workability Without Imparing Strength And Durability As Per The Directions Of The Engineer-In-Charge. All Works Upto Floor V Level. M-30 Grade Of Concrete , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Vertical Surfaces Such As Retaing Walls, Return Walls, Partitions, Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets And The Like , Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Suspended Floors, Roofs Landings, Shelves & Their Supports , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates. I.Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only , Providing And Laying Upto Floor Five Level Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 20 Mm Nominal Size) Including Smooth Finishing To Exposed Surfaces, With Cement Mortar 1:3 (1 Cement: 3 Fine Sand) Including Centering And Shuttering Etc.String Courses, Copings, Bedplates, Anchor Blocks, Plain Window Sills And The Like. , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) ) (Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing : In Retaining Walls , Return Walls(Any Thk) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc, Upto Floor Five Level. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Extra For Laterite Masonry In All Sizes In Superstructure From Floor I Level Upto Floor V Level. , Providing And Fixing Exposed Laterite Stone Of 100 Mm Thk For Dado ,Laid On Cement Mortar Paste 1:4 (1 Cement : 4 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Stone Including Rubbing Including Applying Acrylic Varnish Etc Complete. As Per Designs And The Directions Of The Engineer-In-Charge. , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws. , Providing And Fixing Anodized Aluminum Ventilators (Including Frame And Shutter ) With Three Partitions With 5 Mm Thick Approved Clear Float Glass In One Partition, Exhaust Opening In One Partition & 6 Mm Thk Glass Louvers In One Partition With Using Weight And Size Of Section Not Less Then As Specified Or As Shown In Drawing ,Locking Arrangement,Silicon Sealant ,Epdm Gaskets, Including All Aluminum Fixture And Fittings Etc. Complete . All Gaps Between Civil Work And Aluminium Frames Shall Be Sealed And Made Watertight By Applying Silicone Sealant.Rectangular Tube @0.478Kg/M , Providing And And Laying Vitrified Floor Tiles In Different Sizes Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make In Colours And Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigment Etc., Complete. 600X 600 Mm Dark Shades , Providing And Laying Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Lakha Red , Marble Tiles In Risers Of Steps, Skirtings, Dado, Walls And Pillars Laid On 12 Mm (Average) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointed With Grey Cement Slurry Including Rubbing And Polishing Complete With Kotah Stone Slab Flooring Over 20 Mm (Average Thick Base Of Lime Mortar 1:1:1 (1 Lime Putty : 1 Surkhi : 1 Coarse Sand) Laid . Plain White Makrana Slab 25Mm Thick , Marble Stone Flooring With 18 Mm Thick Marble Stone (Sample Of Marble Shall Be Approved By Engineer-In-Charge) Over 20Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement:4 Coarse ) Using : White Makrana Marble , Providing And Laying 300X350x160 Mm Thick Decorative Laterite Stone Flooring (Patradevi Stone) Laid On 20 Mm Thick Base Of Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Maintaining 75 Mm Gap Between Two Stone For Grassing.Gaps To Be Filled With Good Earth For Grassing. All Work Completed As Per Directed By Engineer-In-Charge.(Price Including Stone,Gardening Soil,Fertilizers And Grass Etc Complete). , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification. Size 30 Cm Lx 40 Cm H X 15 Cm T , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Demolishing Reinforced Cement Concrete Work Including Stacking Of Steel Bars & Disposal Of Unserviceable Within 50 Steel Bars & Disposal Of Unserviceable Within 50 , Dismantling The Tile Work In Floors And Roofs Laid In Cement Including Stacking Of Materials Within 50 Meters Lead For Thickness Of Tiles 10Mm To 25Mm. , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing And Fixing Concrete Roof Tiles Of Monier Brand Elabana Series Over Fabrication Structure As Per Manufacture Guidelines, Including Fixing Tiles In Standard Patterns Or As Specified By The Architect. Colour - Orange , Providing And Fixing Monier Concrete Ridges As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , Providing And Fixing Monier Barge Tiles As Required Over Layer Of Topflex Including All Necessary Fixtures Etc. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. 12 Mm Cement Plaster 1 :3 ( 1 Cement : 3 Sand) , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing 19Mm Thk Plywood Work In Frames Of Doors Using 19Mm Marine Ply (Waterproof) With All Hardware,And Other Frames And Fixed In Position With 50 Mm Fastners Etc. Complete As Specified As Shown In The Drawings. , Providing And Fixing First Class Indian Teak Wood Moulded Beading To Door And Window Frames With Iron Screws, Plugs And Priming Coat On Unexposed Surfaces Etc. 50 X 12 Mm , Providing And Fixing Block Board Flush Door Shutters 35Mm Thick ( 1St Class Teak Ply On Both Faces), Laminated On Both Sides With 1Mm Thick Laminate Of Approved Brand And Colour Including Cost Of Adhesive, Nails, Screws During Fixing Etc. Complete. , Providing & Fixing Bright Finished Stainless Steel Mortise Latch & Lock With 60 Mm Cylinder And A Pair Of Levers, Handles With Necessary Screws Etc.Complete , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete. 250 X 16X 5Mm , Providing And Fixing Chromium Plated Brass Butt Hinges With Necessary Screws Etc. Complete Size 125 X 70 X 4.0Mm , Providing And Fixing 150 Mm. Bright Finished Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutter Thickness Complete. , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete , Providing And Applying Decorative Plastering For A Window Sorrounding, Using 1:4 Morter Mixture With Bricks Chips,Featuring A 300Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer. (The Job Involves Applying A Decorative Finish Over Underlying Structure, Incorporation Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Double Piller At The Corner (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center (Ht 3.50 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Piller At The Center For Hall(Ht 2.10 Mt), Using 1:4 Mortar Mixture With Brick Chips, Featuring A 200Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Arch Of Span Of 3Mt., Using 1:4 Mortar Mixture With Brick Chips, Featuring A 150Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering For Flowers At The Ceiling With Dia. 1.20Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Providing And Applying Decorative Plastering Ofr Cornice At Ceiling In Hall Of Ht 0.40Mt, Using 1:4 Mortar Mixture With Brick Chips, Featuring A 60Mm Offset, And Including Custom Moulding Work As Details In Approved Drawings And Direction By The Engineer. (The Job Involves Applying A Decorative Finish Over The Underlying Structure, Incorporating Special Decorative Features Etc Complete. , Construction And Installation 6Mt Height Replica Of Shree Suptakoteswar Stumb Using Sadhahalli Grey Granite Stone With Intricate Carvings, Moulding As Per Drawing. The Structure Should Have 6Mt Ht. With 2.5 X2.5X0.70 Mt Ht At Base And Stumb Of 1.50X1.50X5.25 Mt Height At Top As Per Details Drawings And Direction By The Engineer. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Paduka For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A 150Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Padma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Kumuda For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple At Base Sorrounding(Adhopadma For Plinth), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Big Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 2100Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Karnakuta ), Using 1:4 Morter Mixture With Bricks Chips, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Mantap ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1500Mm Height ,750Mm Width, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Cornice ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Small Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 750Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Big Statue ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 1200Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Adhopadma For Sajja), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 200Mm Height And Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete. , Providing And Applying Decorative Plastering For Temple (Cornice Above Adhopadma ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Providing And Applying Decorative Plastering For Temple (Yalli ), Using 1:4 Morter Mixture With Bricks Chips,Featuring A Max 300Mm Height, Including Custom Moulding Work As Details In Approved Drawings And Direction By Engineer Etc Complete (Including Labours, Materials And Scaffolding Etc) , Electrical Works , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 1/2 Core 70Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 1.5 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 2.5 Sq.Mm , Supply Of 4 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.4 Core 2.5 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(A) In Soily Strata , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 3 1/2 X 70 Sq. Mm. , Supplying And Fixing Following Way Tpn Sheet Steel, Double Door, Horizontal Type Mcb Distribution Board 415 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator)(K) 12 Way (8+36), Double Door, Horizontal Type Cat B , Supplying And Fixing 40 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(E) Tpn, Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Recessed Pvc Conduit(Heavy) With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group C -- With Cat B Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable (With)In Recessed Pvc Conduit(Heavy) And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The (With) Independent Recessed Pvc Conduit(Heavy) Of Appropriate Size As Required.(C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.A) 20 Mm , Supplying And Fixing Of Following Sizes Of Rigid Pvc Conduit Alongwith Accessories In Surface(Medium)/Recess(Heavy) Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.B) 25 Mm , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) 5/6 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required (D) 3 Pin 5/6 A Socket Outlet Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Required B) 15/16 A Switch Cat A , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate And Switch Box Including Connections But Excluding Modular Plate Etc. As Requiredd) 6 Pin 15/16 A Socket Outlet Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Requireda) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(A) 1 Or 2 Module ( 75 Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredb) 4 Module ( 125 Mm X 7 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Required(C) 6 Module (200Mm X 75 Mm) Cat A , Supplying And Fixing Following Size Modular Gi Box Alongwith Modular Base And Cover Plate For Modulator Switches In Recess Etc. As Requiredsitc Of Wall Fan,600 Mm Sweep, With All Accessories. , Supply Installation Testing And Commissioning Of 8-10 W Spot Light Cob Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supply Installation Testing And Commissioning Of W 80W Flood Light Ip65 Light With System Efficacy Of 100 Lm/W.L70 Life Of 50000 Hrs. P.F.0.95 With Thd10% ,Cct 5700 K,Cri 70,Surge Protection 4 Kv. Input Voltage Range Of 120V To 300V.Certification:- Lm79 & Lm80 Test Report Should Be From Govt Approved Inhouse Nabl Lab/ Government Of India Authorised Make Havells/Wipro/Phillips/ Legaaro/Bajaj As Required And Directed By Engineer Incharge , Supplying & Erecting Of Led 20W Tube Light Fitting (4 Feet) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete.(Includes Suspension Accessories). Make: Philips, Reytek, Leska, Crompton, Wipro, Havells As Required As Directed By The Engineer In-Charge , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =600X1500(H),Lamp Base- G9, Wattage- 7X42w Max, Complete With All Accessories. , Supply Installation Testing and Commissioning of Decorative Chandelier Having Finest Crystals In Chrome Finish, Material -Mirror Stainless Steel, Dimensions (Mm) -Dia. =1200X1500(H),Lamp Base- G9, Wattage- 12X42w Max, Complete With All Accessories. , Supply And Erecting Of 48 Inch ( 1200Mm Sweep) Ceiling Fan, Double Ball Bearing Type, , Complete With All Accessories. (B) Cat B , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineerincharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs ( Paid Seperately). D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G)Watering Arrangement(Plumbing Will Be Paid Seperately). , Supply Installation Testing and Commissioning of 12W Multi Color Spot Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Wall Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 12W, Cct : Rgbw, (As Per The Design Approval) Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik05, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik05, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 400Mm. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Linear Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights. Power Consumption : 80W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo Separate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik07, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of High Quality Multi Color Neon Flexible Light, Protection Rating : Ip65, Mounting Structure : Adjustable Wall Mount Ss Clips For Fixing The Lights. Power Consumption : 12W, Cct : Rgb/Rgbw, (As Per The Design Approval) Beam Angle : 120º, Control : Dmx512 Channel : 4 Ch, Power Input : Dc 24V With External Driver, Surge Protection : Inbuilt Surge Protection 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C , Led Life Time Should Be At Least 50,000 Burning Hours At L70 At 25 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Epistar, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. , Supply Installation Testing and Commissioning of High Quality Long Through Multi Color Wash Light, Protection Rating : Ip66, Complying To Bis Standard Is 10322 (Part 5/Sec 1): 2012 And Having Ce Certification Against Standard Low Voltage Directive & Protective Equipment - En 60598-1:2015, And Electromagnetic Compatibility Directive - En 61547: 2009, Mounting Structure : Adjustable Surface Mount Yoke Arrangements For Fixing The Lights Having The Rotation Degrees Embosed In The Die Cast. Power Consumption : 50W, Cct : Rgbw(6000-7000K), (As Per The Design Approval), Optics : Pmma With Holder, Beam Angle : 25º/45º/60º, Control : Dmx512 Channel : 4 Ch, Body : Die Casted / Extruded Aluminium With Embossed Manufacturer Logo, Seperate Compartment For Keeping The Decoder/Driver In The Housing Which Can Be Easily Removable For Service Without Disturbing The Leds/Optics, Hot Spot And Light Distribution : Optics Designed To Minimize Hot Spots & Fringing In Color Mixing Applications. Power Input : Constant Dc 24V With External Driver To The Constant Current Decoder, Surge Protection : Inbuilt Surge Protection In The Driver 2Kv-4Kv(Additional If Required Will Be Added As Per The Requirement), Toughened Transparent Glass Having The Ik Protection Up To Ik08, Painting : Chemical 3/7 Tank Processed Treatment Before The Powder Coat Black/Ash/Approved Color Coat. Fixture Will Be Suitable To Operate In A Temperature Range Of 0°C To 50°C, The Light Fixtures Are Having Ip68 Air Vent Made Of Stainless Steel Which Helps To Desiccate & Prevent From Forming Moisture Inside The Light Fixture At Worst Environmental Condition. Led Life Should Be At Least 50,000 Burning Hours At L70 At 35 Degree Centigrade. Luminaire Is Inclusive Of Integral Male/Female Waterproof Connectors With Structures In Pre Wired Conditions As Per Is Standard. Pcb Thickness Must Be 1.6Mm, 35 Micron Copper, 2W Tc With Black Or White Masking, Copper /Osp Finish. Lm79, Ik07, Ip66, Hv Certificates From Nabl Acrediated Laboratory. Led Makes Should Be Cree, Lumilled, Osram, Seoul, Nichia Or Equivalent With The Engineer Or 3Rd Party Testing Laboratory Approval. Power & Dmx Loop In/Out Along With Ip67 Connector Having The Length 300Mm. , Supply Installation Testing and Commissioning of Aluminium Profile For Neon Flex , Supply Installation Testing and Commissioning of Dc Power Driver For The Above Lights, Power : 200W, Input : Ac 110-240V Ac, 50Hz, Output : Dc 12/24V, Protection Rating, Ip67, Surge Protection : Ll 4Kv, Le 6Kv , Supply Installation Testing and Commissioning of High Quality Dmx Decoder, Power Input : Dc 24V , Supply Installation Testing and Commissioning of Pvc Insulated Multi Core Electrical Un Armoured Flexible 5C X 0.5Sq Mm Power Cable Having Less Electrical Losses. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 5 Core Dmx Cable Comprises Twisted Pairs With Shield Support For Carrying Of Data. Dmx512 Cable Is Used For Connecting All Light Consoles That Use Dmx 512 Standard Data Transmission. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete For Both Power And Dmx. (As Per Actuals Depending Upon The Site Condition) , Supply Installation Testing and Commissioning of Ip65 I Power Connectors Having 3/4 Pole Cable Connector, Chuck Type Strain Relief, Current Rating 20 A Rms Continuous, Easy And Extremely Precise Locking System Quick Lock High Impact Materials - Long-Lasting And Reliable , Supply Installation Testing and Commissioning of Ip65 I Dmx Connectors Having 3/5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Male Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of 5 Pin Xlr Female Connectors Having 5 Pole Cable Connector, Male/Female Connector With Improved Latch, Cage Type Contacts, Solder Stop For Easy Soldering, And Additional Ground Contact For Best Contact Integrity Between Chassis And Cable Connector. More Durable Housing For Maximum Reliability. , Supply Installation Testing and Commissioning of Power Distribution Board Made Up Of Ms Sheet Metal Fabricated Housing Black Powder Coated And Ivery Connectors For The Internal Terminations And External Outgoing Connecting Points, Fibre / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. Timer With Required Contactor For Auto Switching. Power Panel Suitable For Indoor/Outdoor Applicable And Floor Mount / Wall Mount Options. - 12 Nos Of 6/10A Sp Outgoing Mcbs. - 1No Of 32A Tpn Incoming Mcb. , Supply Installation Testing and Commissioning of Ip Driver Box Made Up Of Pvc / Upvc And Ivory Connectors For The Internal Terminations And External Outgoing Connecting Points, Fiber / Brass Glands Of Suitable Size Fitted Mcb Control For Outgoing Circuits. , Supply Installation Testing and Commissioning of Dmx Isolator Or Splitter Provides Isolated Optical Dmx Splitter Provides 8 Outputs From A 1 Input And Input Voltage: Ac 110 To 220 V, 50 Hz, Product Features: Group 1 & Group 8 Dmx Signal Change. , Supply Installation Testing and Commissioning of Din Rail Mount Dmx Controller Can Be Used To Control A Wide Variety Of Different Dmx Systems- From Rgb/Rgbw To More Advanced Moving And Color Mixing Luminaires, Dmx Audio Players And Fountains. The Controller Comes With A Variety Of Features, Iphone/Ipad/Android Remote Control, Wi-Fi Facilities, Dry Contact Port Triggering And Flash Memory.Usb Connection • 1024 Dmx Channels Universe In Live Mode (Computer) • 8 Dry Contact Trigger Ports Via He10 Connector • Stand Alone Mode With 5 Area And 90+ Scenes, Mac Osx 10.6/10.7/10.8 - Windows Xp/Vista/Seven/8 32/64 Bits And Usb 2.0, Xlr3, Mini Usb, 1 He10, Power From 5V To 5.5V Dc (Ac/Dc Adapter In Option. , Supply Installation Testing and Commissioning of Programming Charges , Supply Installation Testing and Commissioning of Additional Accessories For Installing The Lights As Per The Final Drawing/Site Condition Consisting Of Clamps, Brackets, Angles, Conduits, Joints, Hardwares Like Fasteners, Nut & Bolts Etc., , Street Light Panel: Supply, Installation, Testing And Commissioning Of Lt Panel Ip- 67 Outdoor Type,Floor Mounted Panel, Shall Be Suitable For 415 V, 3 Phase, 4 Wire, 50Hz Supply System. With 3 Phase Energy Meter And 100A Tpn Mcb As Incommer And 11 Nos Of Tpn Mcb As Outgoing With 3 Numbers Of Microcontoller Based Programmable Digital Almac Timer As Directed By Engineer In-Charge
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
34.
Defence #11162654 Technical Bid
Tender for Material & Labour For Light/Fan Point Wiring With 1.5 Sq Mm (Nominal Area), Pvc Insulated Unsheathed (Frlsh), 1100 Volts Grade, Multi-Stranded Copper Conductor, In And Including Pvc Casing Capping Of Adequate Size With All Fittings And Accessories Including Pvc Boxes For Housing The Switches ( Make Of Box Prestoplast,Prestoteak), Including Pvc Insulated And Sheathed (Frlsh)Single Core Multi-Stranded Copper Conductor Cable Of Size 1.5 Sq Mm Green In Colour As Earth Continuity Conductor Connected To Common Earth Dolly Complete All As Specified And Directed. , All As Per Item No. 1 Here In Before But For One 3 Pin Socket Outlet 5/6 Amps Three Pin Controlled By One Switch On Independent Board Complete All As Specified And Directed. , All As Per Item No. 1 Here In Before One 3 Pin Socket Outlet, 5/6 Amps On The Same Board With Other Switches, With Cables 1.5Sq. Mm Size Complete All As Specified And Directed. , All As Per Item No. 1 Here In Before But For One 5 Pin Socket Outlet 15/16 annual periodical maintenance And 5/6 annual periodical maintenance Multipurpose Independent Using 2.5 Sqmm Copper Conductor Cable (Multi-Strand) Pvc Insulated And Unsheathed Cable And 2.5 Sqmm Copper (Multistrand) Pvc Insulated And Unsheathed Earth Wire With Pvc Boxes Complete All As Specified. , All As Per Item No. 1 Here In Before One Light Point Controlled By Two Two-Way Switch 5/6 annual periodical maintenance Complete All As Specified And As Directed . , All As Per Item No. 1 Here In Before One Bell/Buzzer Point Controlled By One Bell Push Complete All As Specified And As Directed . , Supply & Fixing Switch Piano Flush Type (Isi Marked), Single Pole, One Way 5/6 Amp, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Switch Piano Flush Type (Isi Marked), Single Pole, One Way 15/16 Amp, 240 Volts Complete All As Specified & Directed. , S&F Socket Outlet 2 In 1, 5 Pin, 5/6 annual periodical maintenance Flush Type , S&F Socket Outlet 2 In 1, 5 Pin, 5/6 And 15/16 annual periodical maintenance Flush Type , S&F Switch Socket Combination 2 In 1, 5 Pin, 5/6 And 15/16 annual periodical maintenance Flush Type Universal Complete All As Specified And Directed. , S&F Switch Socket Combination 2 In 1, 5 Pin, 5/6 annual periodical maintenance Flush Type Universal Complete All As Specified And Directed. , S&F Switch Socket Combination With Box 2 In 1, 5 Pin, 5/6 And 15/16 annual periodical maintenance Flush Type Universal Complete All As Specified And Directed. , S&F Switch Socket Combination With Box 2 In 1, 5 Pin, 5/6 annual periodical maintenance Flush Type Universal Complete All As Specified And Directed. , Supply Only Pvc Self Adhesive Insulation Tape Multi Colour Of 12.5 Mm Thick For Electric Wire Complete All As Specified And Directed. , S&F Led Driver Single Phase Input Voltage 220 Volt-240 Volt Ac 50 Hz, providing fixing Not Less Than 0.95, Suitable For 36/20/15 Watt Led Light As Per Site Requirement Complete All As Specified And Directed. , Supply And Fixing In Replacement Of Ceiling Rose, Surface Bakelite, 65Mm X 50Mm , Two To Three Terminals Complete All As Specified & Directed. , S&F Bell/Buzzer Push 5/6 Amp,Flush Type Complete All As Specified & As Directed , S&F Call Bell Ding Dong Electric Ac, 240 Volt, 50 Hz, Surface Type Complete All As Specified & As Directed. , Supply & Fixing Modular Switch 1 Way 6A,1 Module, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Modular Switch 1 Way 16A,1 Module, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Modular Socket, 6A - 5 Pin Combined 2 Module, 240 Volts Complete All As Specified & Directed. , Supply & Fixing Modular Socket 6A/16A - 5 Pin Combined 2 Module, 240 Volts Complete All As Specified & Directed. , S&F Modular White Cover Plate With Frame 02 Module , S&F Modular White Cover Plate With Frame 03 Module , S&F Modular White Cover Plate With Frame 06 Module , S&F Modular Metal Flush Box 1/2 Module , S&F Modular Metal Flush Box 3 Module , S&F Modular Metal Flush Box 6 Module , Supply And Fixing Led Light Fitting 4 Feet (Cool White) 1 X 20 Watt 220 Volt Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Size From Ceiling Rose Complete All As Directed. , Supply And Fixing Led Light Fitting 4 Feet ( Warm White ) 1 X 20 Watt 220 Volt Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Size From Ceiling Rose Complete All As Directed. , Supply And Fixing Led Light Fitting Mirror Type With High Out Put Diffuser 2 Feet, 10 Watt 220 V Ac Decorative Type With Driver Holder And Led Lamp Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Led Tube Rod 4 Feet,20 Watt 220 V Ac Complete All As Specified & Directed. , Supply And Fixing Of Batten Suitable For Fixing Led Lights 20 Watt, 220V, Ac With Holder Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete. , S&F Downlighter Round 18 W (White/Warm White) Recess Mounting Type & Driver Of Various Sizes As Per Site Requirement Incl Integrated Electronic Driver Including Taking Down Old Unsv One Complete All As Specified And Directed , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Cool White) Surface Mounting Type With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Site Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Warm White) 220 V Ac Surface Mounting Type With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Site Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Cool White) 220 V Ac Recessed Mounting Type With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Site Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F In Replacement Of Led Luminaire 600 Mm X 600 Mm, 35/36 Watt, (Warm White) 220 V Ac Recessed Mounting Type With High Efficiency Pmma Diffuser Soft Glare Free Light Of Colour White/Warm White As Per Requirement At Site Complete With Driver, Holders & Led Lamp Suitable For Roof Ceiling Including Connecting Up With Driver Three Core Flexible Copper Conductor Cases Of Suitable Size Complete All As Specified And Directed. , S&F Led Lamp 5 Watt, 230W, B-22, providing fixing Not Less Than 0.85 (Min). , S&Fled Lamp 9 Watt, Cool White/Warm White, 230W, B-22 , providing fixing Not Less Tha 0.85 (Min) Complete All As Specified And Directed. , S&F Led Lamp 12 Watt, Cool White/Warm White, 230W, B-22 , providing fixing Not Less Tha 0.85 (Min) Complete All As Specified And Directed. , S&F Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light Made Up Of Innovative Die Cast Aluminium Housing High Power Led As Lighting Source With Ip - 66 Power Consumption 45 Watt Complete Input Voltage Of 150-240 Volt (Nominal Rated Voltage 240 Volt) Complete All As Specified And Directed. , S&F Led Bulkhead Fitting 10 Watt (Endura Ruby) With All Accessories And Including Connenting Up With Twin Core Twisted With Flexible Copper Conductor Cable With Suitable Size Of 230 Volts , 50 Hz Complete All As Specified And Directed. , S&F In Repair Supply And Fixing Post Top Lantern Led Type 20 Watt 230 Watt Volts Ac Outdoor Type With Decorative Post Top For 360 Degree Indirect Light Ip 65 Protection With Impact And Corrosion Resistant Complete With Driver And Lamp Complete All As Specified And Directed.Model No Rubyminipt15wled830psymtopc , S&F Decorative Garden Light Pressure Die Cast Powder Coated Housing With Pc Diffuser Efficient High Output Led With Ip 65 Protecton Of Capacity 10 Watt (Cdl/Ww) With All Accessories And Including Connection Up With Twin Core Twisted With Flexible Copper Conductor Cable Suitable Size Of 230 Volts 50 Hz Complete All As Specified And Directed. , Supplying, Laying, Jointing & Testing Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty) With Stranded Aluminum Conductor, 1100 Volts Grade, Of Size 25 Sqmm 4 Core As Per Is 7098 Pt-Ii Laid In Trenches / Ducts / Encased In Gi Pipe / Fixed To Pole Complete All As Directed And Specified. , Supplying, Laying, Jointing & Testing Cable Xlpe Insulated Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables (Heavy Duty) With Stranded Aluminum Conductor, 1100 Volts Grade, Of Size 16 Sqmm 4 Core As Per Is 7098 Pt-Ii Laid In Trenches / Ducts / Encased In Gi Pipe / Fixed To Pole Complete All As Directed And Specified. , S&F In Replacement Of 1100 Volts Grade Heavy Duty Isi Marked Cable Pvc Insulated Stranded Aluminium Conductor One Twin Core Cable Flat Or Circular Of Size 16 Sqmm Served With Inner Sheathing Of Pvc Tape & Overall Pvc Sheathed In Service Connections Complete All As Specified And Directed. , Description All As Per Item No. 49 Above But One Twin Core Cable Flat Or Circular Of Size 10 Sqmm Complete All As Specified And Directed. , Description All As Per Item No. 49 Above But One Twin Core Cable Flat Or Circular Of Size 6 Sqmm Complete All As Specified And Directed. , Description All As Per Item No. 49 Above But One Twin Core Cable Flat Or Circular Of Size 4 Sqmm Complete All As Specified And Directed. , Supply And Fix Sheet Metal Enclosures For Dbs Double Door When Mcbs To Be Used 230 Volts 4 Way 200 annual periodical maintenance Rated Busbar Single Pole And Neutral Fixed On Wall Duly Grouted In Solid Block Wall Or On Wooden Board Complete All As Specified And Directed. , Supply And Fix Sheet Metal Enclosures For Dbs Double Door When Mcbs To Be Used 230 Volts 8 Way 200 annual periodical maintenance Rated Busbar Single Pole And Neutral Fixed On Wall Duly Grouted In Solid Block Wall Or On Wooden Board Complete All As Specified And Directed. , Supply And Fix Sheet Metal Enclosures For Dbs Double Door When Mcbs To Be Used 230 Volts 12 Way 200 annual periodical maintenance Rated Busbar Single Pole And Neutral Fixed On Wall Duly Grouted In Solid Block Wall Or On Wooden Board Complete All As Specified And Directed. , S&F Mcb Spn Having Braking Capacity 10Ka, 32 Amps, 240 V Complete All As Specified And Directed. , S&F Mcb Sp Having Braking Capacity 10Ka, 6 To 32 Amps, 240 V Complete All As Specified And Directed. , S&F Mcb Tpn 63 Amps 415 V Complete All As Specified And Directed. , S&F Mcb Tp 40 Amps 415 V Complete All As Specified And Directed. , S & F In Replacement Of Mccb, 04 Pole, Capacity 63/100 Amps With Ultimate Breaking Capacity 16 Ka At 415 Volts With Fixed Thermalsettings Conforming To Iec 60947 Part-I/Is-13947 Part-I , (Ics=Icu=100%) In The Existing Panel With Suitable Connecting Copper Terminals At Site Complete All Specified And Directed. , S & F In Replacement Of Mccb, 04 Pole, Capacity 125 Amps With Ultimate Breaking Capacity 16 Ka At 415 Volts With Fixed Thermalsettings Conforming To Iec 60947 Part-I/Is-13947 Part-I , (Ics=Icu=100%) In The Existing Panel With Suitable Connecting Copper Terminals At Site Complete All Specified And Directed. , S & F In Replacement Of Mccb, 04 Pole, Capacity 160 Amps With Ultimate Breaking Capacity 36 Ka At 415 Volts With Fixed Thermalsettings Conforming To Iec 60947 Part-I/Is-13947 Part-I , (Ics=Icu=100%) In The Existing Panel With Suitable Connecting Copper Terminals At Site Complete All Specified And Directed. , S&F Mccb Dbs Vtpn Type Double Door In Wall / Nitch When Mcbbs ,To Be Used Four Pole And Neutral, 8 Way,415 Volt With Rated Bus Bar ,Suitable For Flush Mounting And Surface Mounting With 160 Amps Copper Bus Bar For Each Phase And 2 Neutral Bar, 2 Earth Bar, And Cable Ties For Cable Managent,Fully Insulated Busbar And Shrouded Neutral Bar ,Improved Pan Assembly For Ease Of Installation ,Prefitted Masking Sheet, Reversible Door For Ip 43 &Ip 54 Dbs With Provision For Dpx3 160 Mccb As Incomer, And Tpn /Spn/Dp/Sp Out Going . Complete All As Specified And Directed. Ip :54 Protection , Excavation In Trenches In Any Type Of Soil Not Exc 1.5 Mtrs Wide And Not Exc 1.5 Mtr In Depth For Laying Of Pipe/ Cables/ Poles Etc And Getting Out Any Type Of Soil Complete All As Specified And As Directed. , Returning Fitting In Any Type Of Soil Including Spreading Leveling Watering And Well Ramming In Layers N.Exc 25 Cm Complete All As Specified And As Directed. , Removing Excavated Soils To A Distance N.Exc. 50 Mtr And Depositing Where Directed At A Level Not Exc 1.5 M Above The Starting Point Complete All As Specified And As Directed. , M & L For Laying Of Fine, Clean Sand (River Sand) Free From Sharp Materials And Stone Particals In Trenches For Cushioning Of Cable 8 Cm Thick Under Cable And 15 Cm Thick Over The Cable Including Gently Punning Complete All As Specified And Directed. Note:- The Total Thickness Of Sand Shall Be Measured 18 Cm After Punning. , Supply And Laying Un-Reinforced Precast.Concrete Cable Protection Cover Of Class Lv, Type-1, Flat Size 250Mm X 150Mm X 40 Mm, Factory Made Of Specified Make , Complete All As Specified And Directed. , Supply And Laying Galvanised Tube Light Grade Isi Marked Of Size 40 Mm Dia Incl All Fittings In Trenches/Fixed On Pole/Wall/Floor Or Laid In Position Including Repairing Of Demolished Cemented Portion Complete All As Specified And Directed. , Supply And Fix In Replacement Electronic Meters Single Phase Temper Proof Lcd Display With Polycarbonate Cover 230 V, 10-60Amp, Accuracy Class-I 50Hz, Conforming To Is 13779, Ip-54, With Parameters To Show Data, Time, Current Reading, Load, Pf, Voltage And Kwh Complete All As Specified And Directed. , Taking Down Of Defective Geyser Of Any Capacity From Different Locations For Repair Including Removing Of Electric Connection, Pipe Fitting Without Any Damage And Refixing The Same After Repair In Same/Desired Location Complete All As Specified & Directed. Note :- The Parts Required For Repair Shall Be Measured Separately Under Relevent Item Of Sch A , S&F Copper/Ss Body Inner Shell Suitable For Water Storage Heater (Geyser) Of 25 Ltr Capacity As Per Sample Including Taking Down Old Unsv Steel/Copper Tank Complete All As Specified And As Directed , S&F Outer Body Of Water Storage Heater (Geyser)Of 25 Ltr Capacity As Per Sample Including Taking Down Old Unsv Outer Body Complete All As Specified And As Directed , M&L For Glass Wool Packing Required For Cover The 25 Ltrs Copper Inner Shell To Avoid The Heat Conduction Including Taking Out Old Packing All As Specified & Directed. , S&F Heating Coil 2000/1500 Watt (Round/Trinangle Type) In Existing Storage Water Heater(Geyser) Suitable For 25 Ltrs Capacity All As Specified & Directed. , S&F Thermostat Range Of 30-80 Degree, As Per Site Requirement, Size As Per Sample All As Specified & Directed. , S&F Non Return Valve Brass Suitable Of 15 Mm Dia Including Taking Down All As Specified & Directed. , S&F Steel Pipe Connection 60 Cm Long Both End Brass Suitable For Hot Water Supply And Screw Down 15 Mm Gi Pipe Complete All As Specified & Directed. , M&L For Replacement Of 12 X 100 Mm Bolts Grouting In Bricks Masonary Wall With 1:4 Cm For Mounting Geyser All As Specified & Directed. , M&L Base Plate Suitable For Hanging Of Geyser Of Capacity 25 Ltr , Taking Down Of Defective Exhaust Fan Any Capacity/Make/Model/Size From Its Original Locations For Repair Including Sealing Of Cable End , Dismantling Blades, Clamps With Bush, Louvers & Motors, Refixing The Same After Repair & Assembling Complete Set In Same Location Etc Including Testing Complete All As Specified & Directed , M&L For Rewinding Of Exhaust Fan Motor 150/225/230/250 Mm Sweep 240 Volt Ac After Dismantling Complete Motor Assay, Bearning, Bushings, Removal Of Burnt Copper Wire, Cleaning Of Core Inserting Proper Insulating Paper In Slots Winding With Copper Wire As Per Existing Gauge And Assemble Complete Set Complete All As Specified And Directed , M&L For Rewinding Of Exhaust Fan Motor 300/450 Mm Sweep 240 Volt Ac After Dismantling Complete Motor Assay, Bearning, Bushings, Removal Of Burnt Copper Wire, Cleaning Of Core Inserting Proper Insulating Paper In Slots Winding With Copper Wire As Per Existing Gauge And Assemble Complete Set Complete All As Specified And Directed , S&F In Repair/Replacement Fan Blade Suitable For Exhaust Fan 150/225/230/250 Mm Sweep Metal/Plastic Body , S&F In Repair/Replacement Fan Blade Suitable For Exhaust Fan 300/450 Mm Sweep Metal Body . , S&F In Repair/Replacement Ball Bearing Of Exhaust Fan Of 150/225/230/250 Mm Sweep As Per Existing Type Complete All As Specified And Directed , S&F In Repair/Replacement Ball Bearing Of Exhaust Fan Of 300/450 Mm Sweep As Per Existing Type Complete All As Specified And Directed , S&F In Repair/Replacement Capacitor Of Cap 1/1.5/3.15 Mfd Sutitable For Exhaust Fan Of 150/225/230/250/300/450 Mm Sweep As Per Existing Type Complete All As Specified And Directed , S&F In Repair/Replacement Of Exhaust Fan Motor Suitable For Exhaust Fans 150/225/230/250 Mm Sweep Plastic/Metal Body. , S&F In Repair/Replacement Of Exhaust Fan Motor Suitable For Exhaust Fans 300/450 Mm Sweep Metal Body. , Material & Labour For Earthing Complete With Galvanised Steel Earth Plate Electrode 600X600x6 Mm Thick Buried Directly In Ground (Earth Pit Not Less Than 2.25M Deep Below The Ground Level) With Top Edge Of The Plate Not Less Than 1.5Mtr Below The Normal Ground Level Connected To Galvanised Wire 4Mm Dia By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron.Earth Wire Protected By Gi Pipe 15 Mm Bore(Medium Grade) And Connected To Main Switch Board Or Main Control Board As Directed And As Specified And Shown In Electrical Plate No. 3 Of Ssr Part I (2009) Including Necessary Concrete Pit In Plain Cement Concrete (1:3:6) Type C1, Pre-Cast Reinforced Cement Concrete (1:2:4) Type B1 Cover Slab 40 Cm X 40Cm X 5Cm Reinforced With 8Mm Dia Tmt Bars @ 15Cm C/C With One Handle For Lifting Made Out Of 8Mm Dia Bar, Funnel, Wire Mesh, 20Mm Dia Gi Pipe Medium Grade For Watering, Charcoal Or Coke And Salt In Alternate Layers Including Necessary Excavation And Earth Work In Any Type Of Soil And Testing Complete All As Directed By Engineer-In-Charge. , S&F Wire For Circuit/Sub Main Wiring With 1100 Volts Grade Double Core Pvc Insulated And Unsheathed Cable With Multistranded Copper Conductor 4 Sqmm, On Surface Or Recessed Or Drawn In Pvc Casing Capping/Pvc Pipe Along With 4 Sqmm Single Core Copper Conductor Multi Stranded Cable As Earth Continuity Conductor Complete All As Specified And As Directed.(Note: One Rm Pvc Casing Capping/Pvc Conduit ,One Run Of 4 Sqmm Earth Wire And 2 Run Of 4 Sqmm Cable Shall Be Measured As One Run.) , S&F Wire For Circuit/Sub Main Wiring With 1100 Volts Grade Double Core Pvc Insulated And Unsheathed Cable With Multistranded Copper Conductor 6 Sqmm, On Surface Or Recessed Or Drawn In Pvc Casing Capping/Pvc Pipe Along With 6 Sqmm Single Core Copper Conductor Multi Stranded Cable As Earth Continuity Conductor Complete All As Specified And As Directed.(Note: One Rm Pvc Casing Capping/Pvc Conduit ,One Run Of 6 Sqmm Earth Wire And 2 Run Of 6 Sqmm Cable Shall Be Measured As One Run.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Arunachal Pradesh View Result →
35.
Defence #11149786 AOC
Tender For Provision Of Deficient Smqs At Najafgarh Under Ge Af Tughlakabad - SCH A PART XI (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule A Part-II. 11 INTERNAL WATER SUPPLY 12 Supply and fixing Health Faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia fixing in pipe with 1.25 meter long flexible tube and ABS wall hook including making connection and fixed to 15mm bore completeall as specified and directed. 13 Supply and fixingangle valve of cast coper alloy chromium plated fancy type screwed down high pressure with crutchor butterfly handle screwed both ends for iron pipe or for unions and fixed 15 mm bore (concealed) complete all as specified and directed. 14 Supply and fixing 15mm dia Two Way Bib taps, fancy type,,cast copper alloy chromium plated with crutch or butterfly handle, screwed down for CPVC pipe or for brass ferrule and fixed complete all as specified and as directed. 15 Supply and fixingBrass CP Mixer for mixing hot & cold water screwed down for 15 mm dia CPVC Pipe and fixed all as specified and as directed. 16 INTERNAL ELECTRIFICATION 17 Supply and fixing LED Lamp 9 watt 220 volts AC of suitable size complete all as specified and as directed. 18 Supply and fixing LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 19 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 20 Supply and Fixing LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.complete all as specified and as directed. 21 Supply and fixingLED Building Securitylight fitting 25 watt complete all as specified and directed by Engr -in- charge. 22 Supply and fixingGI light gradepipe 1.5m long bend to 45 degree andof diameter 25 mm suitable to building security light power cord pipediameter with necessary clamps of for fixing building security light all as specified and directed including making hole to wall if necessary (For Bldg Security Light) complete all as specified and as directed. 23 Supply and fixing MCCB 63 Amps 4P 25 KA 415 Volt Make Indoasian Cat No 830020 includingMCCB Enclosure for 63 Amp MCCB Make Indoasian Cat No 811985 fixed on wooden board of appropriate size for mounting of enclosure complete all as specified and as directed.NOTE:-Rate inclusive of Fixing of cable including lugging complete (For06 Qtrs) 24 Supply and Fixing ceiling fan 230V, 50 Hz AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as specified and directed. 25 Supply and Fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm (for Toilets) complete all as specified and as directed. 26 Supply and Fixing exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m (for Kitchen) complete all as specified and as directed. 27 Supply and Fixing electric water heater, storage type steel body and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate, NRV, connection piece etc. complete all as specified and as directed. 28 Supply and fixing Smart RF/CellularSingle Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 315 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt Radio Frequency communication facilitywith self healing mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry including Polycarbonate Meter Box of minimum suitable size for 1 Phase meter with viewing glass, concealed hinge and earth bolt plugged complete all as specified and directed. Meter Should support sending the following data : 15/30 min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, monthly billing survey for Cumulative Energy and Max Demand to software Meter should have connect / disconnect functionality operable from mdm/billing software and prepaid features would be MDM / Billing end as per prevalent IS . Including Taking down of existing meter and deposit to MES store yard for safe custody all as specified and as directed (For06 Qtrs)Note:- Contractor has to ensure integration and maintainance of the above 06 nos of meters withthe existing Advance Metering infrastructure (AMI) of smart meters of different makeswithout any additional infrastructure and cost implication. 29 EXTERNAL WATER SUPPLY 30 Material and Labour for valve chamber of internal size 750x750x750 mm comprising of 50 mm thick PCC 1:5:10 type E2 foundation, 200 mm thick brick wall in CM 1:6 ,15 mm thick plastring in CM 1:4 internally and externally up to 50 mm below GL, 100 mm thick PCC 1:3:6 type B1 as in coping, 3 mm thick MS sheet cover with suitable hinges and locking arrangements, painting steel surfaces with two coats of synthetic enamel paint over a coat of primer including necessary earth work and excavation in any type of soil complete all as specified and as directed. 31 EXTERNAL ELECTRIC SUPPLY 32 Supply and fixing of LED security/street light fitting 1x70 W LED 5700K energy saving and environmental friendly long life versatile pressure die cast aluminium hosing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LEDs as light source and electronic driver suitable for pole dia 40mm including 45mm dia light grade tube bracket, bent to shape, 1.8 mtr lenght with two Nos clamp of size 50mmx6mm with nuts,bolts,washers etc. including connection with 1.5 sqmm two single core PVC insulated and PVC sheathed cable stranded copper conductor upto ceiling rose and fixing on walls/pole complete all as specified and as directed. 33 Supply and fixingof LT Panel board outdoor type, double door, fabricated made of MS/CRCA sheet 3.15 mmm thick with MS angle frame of size 50x50x6 mm with locking arrangements cubical type feeder pillar box with 04 Nos legs including necessary PCC work with suitable size of PCC 1:3:6 including necessary insulators and 04 Nos of copper bus bar of size 30 mm x 5 mm capacity of 600 Amp with Air circuit breaker, provision of inlet and outlet cable glands and earth connection lead etc complete and connection of all incoming and outgoing cable using aluminium terminal sockets/lugs duly crimpled and necessary two coats of paint with approved make and colour and grade of first quality synthetic enamel paint over a coat of red oxide primer including necessary preparation of surfaces and the panel should be dust and vermin proof factory fabricated , CPRI approved totally enclosed free standing /wall mounting type suitable for 415 vots, 50 HZ 3 phase 4 wire system complete in all respect and confirming to latest relevant of ISI specifications including necessary connections, inter connections with copper conductor cable of required size including MS angle frame of size 50x50x6 mm structure at bottom and with including the following accessories.:- 34 INCOMING :- (i) MCCB,AC 415 Volts, adjustible thermal release, 4 pole current rating 63 Amps, breaking capacity 16 KA (ICS=ICU=ICW for 1 Sec) with fixed type overload protection,short circuit protection = 01 No.(ii) 4 strip copper bus bar of size 30 x 5 mm with specific colour (R,Y,B) insulation = 01 set(iii) Metering panel comprising,voltmeter and ammeter, digital type with selector switches CTs, control fused and indicating lamps. OUTGOING : (i) MCCB,AC 415 Volts, adjustible thermal release, 3 pole current rating 32 Amps, breaking capacity 16 KA (ICS=ICU=ICW for 1 Sec) with fixed type overload protection,short circuit protection = 02 Nos for (01 No Building & 01 No. spare) (ii)MCB SPN 32 amp 215 volts C curve (for street light) = 01 No.(iii) Digital Voltmeter 0-500 volts - 01 No.(iv) Digital Ammeter 04-400 Amps - 01 No. (v) Indicator lamps Red, Yellow & Blue.(vi) Complete wiring of Panel Board.(vii) CT ratio 400/5 Amps 35 Supply and fixing SMC junction box, pole mounted, 100% weather proof, fire retardant , complete with side hinged door of size 250x200x105 mm , made out of engineering plastic including 3 phase 4 wire aluminium bus bar of capacity 60 amp of required size complete with bus bar insulator fibre/ porcelain and one no single pole MCB SPN 6 Amp . B Curve and box fixed on pole with clamps made out from MS flat iron of size 25x5 mm with nute and bolts complete all as specified and as directed. 36 Material and Labour for sub main wiring with 2 run of 1.5 sqmm multistand copper conductor , PVC insulated, 1100 volts grade in and including PVC condut with 1.5 sqmm PVC insulated multistrand copper earth continuity conductor including lugs of suitable size from light fitting connector to looping box on pole complete all as specifed and directed. 37 AREA DRAINAGE 38 Material and labour for pre-cast perforated RCC drain cover with frame ( rectangular or square) the area of each cover should not be more than 0.5 square meter and thickness of 60 mm each with holes, manufactured with M-30 grade of concrete by vibro compacting process using accurately designed moulds and suitably reinforced to enable the covers to take load as specified i.e M-20 MT for heavy duty (When tested as per IS -12592) complete all as specified and as directed. 39 SEWAGE DISPOSAL 40 Supply, laying in trenches and jointing of 200 mm dia bore double wall corrugated polyethelene (HDPE) pipe of stiffness class designation SN8 including all necessary jointing material and fittings such as couplers, connectors,bends, elbows ,Tees and end caps etc complete all as specified and as directed
Contract Date: May 22, 2026 Contract Value : 1.91 Crore
Statutory Bodies & Commissions/Committees No of Bidders 3
Contract Date: Ref. Documents Contract Value : 38.23 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : 21.55 Lakh
Boards / Undertakings / PSU No of Bidders 5
Contract Date: Ref. Documents Contract Value : 6.84 Lakh
Boards / Undertakings / PSU No of Bidders 3
Himachal Pradesh View Result →
43.
Educational and Research Institute #11098868 AOC
Tender For Iehe Bhopal Invites Online Tender For Supply Of Sound System In The Institute , Sound System , Wall Mount Cabinet Loudspeaker General Requirements: The Loudspeaker Shall Be A Cost-Effective, 12W General-Purpose Cabinet Speaker Designed For Indoor Surface-Mount Applications. It Must Be Suitable For Both High-Quality Speech Intelligibility And Background Music Reproduction Acoustic Performance: Rated Power: 12W, With Adjustable Power Tappings At 12W, 6W, And 3W To Allow For 3 Db Step Adjustments. Sound Pressure Level (Spl): Must Provide A Maximum Special Of 102.0 Db At 6W/1M (1 Khz) And A Sensitivity Of 91.7 Db At 1W/1M (1 Khz). Frequency Range: The Effective Frequency Range Shall Be From 150 Hz To 15 Khz. Opening Angles: Horizontal: 184° (1 Khz) / 86° (4 Khz). Vertical: 66° (1 Khz) / 58° (4 Khz). Electrical Specifications: Input Voltage: Designed For 100 V Line Systems. Rated Impedance: 833 Ohms. Connection: Shall Feature A 4-Pole Push-In Terminal Block On The Rear Panel For Easy On-Site Wiring And Power Tapping. Durability: The Unit Must Be Tested For 100 Hours Of Continuous Operation At Rated Power In Accordance With Iec 268-5 Standards. Mechanical Construction Enclosure Material: The Main Body Shall Be Constructed From Solid Mdf (Medium Density Fiberboard) Covered In Durable, Easy-To-Clean Black Vinyl. Front Grille: The Front Shall Be Abs Plastic Covered With A Fine Woven Cloth In Matching Black. Baffle Design: Shall Feature An Angled Front Baffle To Optimize Sound Distribution Within The Listening Area. Mounting: The Rear Panel Must Include Three Keyholes For Quick And Secure Wall Mounting. Dimensions: 445 Mm X 151 Mm X 150 Mm / 111 Mm Environmental Limits: Operating Temperature: -5 °C To +55 °C, Storage Temperature: -40 °C To +70 °C , Wireless Microphone System General System Requirements: Classification: The System Shall Be An Entry-Level Professional Wireless Microphone System Designed For Ruggedness And Ease Of Use In Daily Operations. Ease Of Setup: The System Must Include A One-Button Automatic Frequency Scanning Function To Identify The Clearest Available Channel. Transmitter Synchronization Shall Be Achieved Via An Infrared Data Link To Ensure Error-Free Setup. Frequency Management: The System Shall Provide 32 Preset Channels, With Compatible Groups Of Eight Channels For Simultaneous Multi-Channel Use. Operating Bands: The System Shall Be Available In Multiple Rf Frequency Bands, Including: A Band: 618-634 Mhz. B Band: 678-694 Mhz. C Band: 516-532 Mhz. E Band: 850-865 Mhz. Receiver Specifications Type: Synthesized Pll With True Antenna Diversity To Ensure Stable Rf Reception. Chassis: The Receiver Must Feature A True Rack-Mountable Metal Chassis Suitable For Professional Installation. Rf Performance: Sensitivity: 1.0 Μv For 12 Db Sinad. Image Rejection: Greater Than 55 Db. Audio Outputs: Balanced Output: 20 Dbv (Max @ 40 Khz Deviation). Unbalanced Output: Adjustable From 8 Mv To 0.755V Rms. Display: Front-Panel Backlit Lcd Displaying Channel, Frequency, And Battery Status. Handheld Transmitter Construction: The Transmitter Shall Feature A Rugged Metal Body Designed To Withstand The Rigors Of Daily Use. Microphone Capsule: Equipped With A Cardioid Dynamic Capsule (Pl22) For Effective Feedback Control And Ambient Noise Rejection. Battery Life: Must Operate For A Minimum Of 14 Hours Using Two Aa Alkaline Batteries. User Interface: Features A Backlit Lcd Display And A Dedicated Mute Function To Protect The Audio Channel. Bodypack Transmitter Construction: Compact And Rugged Metal Enclosure. Input Connector: Industry-Standard Ta4F Connector For Compatibility With Various Lapel Or Headworn Microphones. Antenna: Flexible External 1/4 Wave Antenna. Acoustic & Environmental Performance System Frequency Response: 80 Hz - 18 Khz ± 2 Db Signal-To-Noise Ratio: 100 Db A-Weighted Total Harmonic Distortion: 1.0%, 0.4% Typical (Ref 1 Khz, 40 Khz Deviation) , Professional Gooseneck Microphone General Requirements: The Microphone Shall Be A Professional-Grade, High-Quality Electret Condenser Gooseneck Microphone Designed For Public Address Applications Such As Lecterns, Podiums, And Open Conferences. It Must Feature A Sleek, Slender, And Unobtrusive Design To Maintain A Clear Line Of Sight For The User. Acoustic & Technical Performance Transducer Type: Electret Condenser. Polar Pattern: Unidirectional (Cardioid) To Ensure High Front-To-Back Rejection, Providing More Gain Before Feedback. Frequency Response: Wide Range From 20 Hz To 18,000 Hz. Sensitivity: 7.5Mv/Pa Power Requirement: Operable Via A Dc Power Source Ranging From 1.5V To 9V. Mechanical Specifications Overall Length: 585 Mm (Approximately 23 Inches) Output Connector: Built-In 3-Pin Xlr Male Socket For Secure And Standard Professional Connectivity. Optional Accessories (Compatibility) To Ensure System Flexibility, The Microphone Must Be Compatible With The Following Manufacturer-Specific Accessories: Microphone Base: A Sturdy, Heavy-Duty Die-Cast Aluminium Base With An Integrated On/Off Switch, Led Indicator, And Built-In Housing For 2 Times 1.5V Um-3 Aa Cells To Power The Condenser Element. Mic Stand Adaptor: A Rugged Aluminium Die-Cast Body With A Female Xlr Connector For Direct Mounting And A Male Xlr Bottom Connector For Cable Attachment. It Must Include A 10-Meter Shielded Cable And A Threaded Brass Ferrule 5/8 27 Tpi For Standard Stand Mounting. , Mixer Amplifier General System Requirements Type: The Unit Shall Be A Professional 120W Mixer Amplifier With Integrated Usb And Bluetooth Capabilities, Designed For Public Address And Background Music Applications. User Interface: The Amplifier Shall Feature A Simplified User Interface With Preferred Setting Indicators (Colored Pins) For All Front-Panel Knobs To Ensure Ease Of Operation For Non-Technical Users. It Must Include An Led Vu Meter For Visual Output Level Indication And A 6.3 Mm Headphone Socket For Monitoring The Mixer Output. Reliability: The Unit Shall Have No Moving Parts (Such As Hard Drives) To Ensure Long-Term Operational Reliability. Audio Inputs And Media Source Microphone/Line Inputs: Four (4) Balanced Inputs, Switchable Between Microphone And Line Level Sensitivity. Switchable Phantom Power Must Be Available To Support Condenser Microphones. Priority Handling: Input 1 Shall Have The Capability To Take Priority Over All Other Inputs Via Contact Closure (Push-To-Talk) And Include An Optional 2-Tone Chime To Precede Announcements. Music Source: Integrated Media Player: Must Support Playback Of Mp3 And Wav Files (From 32 Kbit/S) Via A Usb Pen Drive (Up To 32Gb Capacity). Wireless Streaming: Built-In Bluetooth For High-Quality Audio Streaming From Mobile Devices. Remote Control: The Unit Must Be Supplied With An Ir Remote Control For The Integrated Music Source. Aux Input: A Separate Stereo Cinch Input, Internally Converted To Mono, With A Sensitivity Of 200 Mv To 300 Mv. Audio Performance And Output Output Power: 120W Rated Output Power. Loudspeaker Outputs: Constant Voltage: 100 V. Low Impedance: 4-Ohm. Call-Only Output: A Dedicated 100 V Call-Only Channel For Priority-Only Areas Or 3-Wire Remote Volume Control Override. Frequency Response: 80 Hz To 18 Khz (+1/-3 Db At -10 Db Ref. Rated Output). Distortion: 1% At Rated Output Power (1 Khz). Tone Control: Dedicated Bass And Treble Controls Providing Max ± 8 Db Adjustment. System Protection: An Integrated Limiter Circuit Must Be Included To Protect The Output Stage From Signal Clipping And Overload. Insert Feature: A Pair Of Rca Cinch Connectors Shall Be Provided To Allow The Unit To Be Used As A Separate Pre-Amplifier And Power Amplifier. Mechanical And Environmental Dimensions: 100 Mm X 430 Mm X 290 Mm (Standard 19 Wide, 2U High). Mounting: Suitable For Both Stand-Alone Use And 19 Rack Mounting. Operating Temperature: -5 °C To +45 °C. Compliance: The Unit Shall Comply With Iec 62368-1 (Safety), Cispr 32 (Emc Emission), And En 55103-2 (Emc Immunity). , Mixing Console General Requirements The Mixing Console Shall Be A Compact, Versatile 6-Channel Analog Mixer Designed For A Wide Range Of Professional Audio Applications. It Must Feature High-Quality Microphone Preamplifiers And A Rugged Construction Suitable For Both Portable And Fixed Installations. Audio Inputs And Processing Input Channels: The Unit Shall Provide A Total Of 6 Line Inputs, Configured As 2 Mono And 2 Stereo Channels. Microphone Preamplifiers: The Console Shall Include 2 Microphone Inputs Featuring Discrete Class-A D-Pre Preamps With An Inverted Darlington Circuit For Superior Sound Quality. Switchable +48V Phantom Power Must Be Available For All Microphone Inputs. Channel Processing: Mono Inputs (Ch1-2) Shall Include A 26Db Pad For High-Level Sources. Each Mono Channel Shall Feature A High-Pass Filter (Hpf) Set At 80Hz With A 12Db/Octave Slope. Equalization For Mono Channels Shall Consist Of A 2-Band Eq: High (10Khz Shelving) And Low (100Hz Shelving) With Pm15 Db Adjustment. Output And Bus Section Buses: The Console Shall Feature 1 Stereo Bus. Outputs: Stereo Out: Provided Via 2 Xlr-3-32 And 2 Phone Jacks (Balanced). Headphones: One (1) Stereo Phone Jack Output With A Dedicated Level Control. Monitoring: Visual Monitoring Shall Be Provided By A 2 Times 7 Point Led Level Meter (Peak, +6, +3, 0, -3, -10, -20Db). Technical Performance Frequency Response: Pm 0.5Db From 20Hz To 20Khz (Referenced To Nominal Output Level @ 1Khz). Total Harmonic Distortion (Thd): 0.01% @ +8Dbu (20Hz To 20Khz), Gain Knob: Min 0.003% @ +18Dbu (1Khz), Gain Knob: Min Hum & Noise: Equivalent Input Noise Of -128 Dbu (Mono Input Channel, Rs: 150Ω, Gain Knob: Max) Crosstalk: -88Db @ 1Khz. Mechanical And Electrical Specifications Chassis: The Unit Shall Be Housed In A Robust, Impact-Resistant, Powder-Coated Metal Chassis. Power Supply: External Ac Adapter: Pa-130 (120V 60Hz) Or Mu18 (100-240V 50/60Hz) Or Equivalent. Power Consumption Shall Be Approximately 12W. , Indoor Wi-Fi6 Access Point General System Requirements Type: The Unit Shall Be A High-Performance, High-Speed 11Ax (Wi-Fi 6) Indoor Dual-Band Ceiling-Mounted Wireless Access Point (Ap). Standard Support: The Wireless Access Point (Ap) Shall Strictly Adhere To The Ieee 802.11Ax (Wi-Fi 6) Standard. Radio Configuration: The Unit Must Be A High-Power Industrial Ceiling-Mounted Ap Featuring 2X2 Mimo Technology For Both 2.4 Ghz And 5 Ghz Bands. Performance: The System Must Provide A Combined Wireless Data Rate Of Up To 3 Gbps To Support High-Speed Applications Such As 4K/8K Streaming And Vr/Ar. User Capacity: The System Shall Support A High Density Of Users, Accommodating Up To 128 Concurrent Users (Max 64 Users Per Band). Advanced Features: The Ap Shall Support Multi-User Mimo (Mu-Mimo), Orthogonal Frequency Division Multiple Access (Ofdma), Bss Color Bit, And Dynamic Cca-Sd For Improved Interference Management. Hardware Specifications Chipset: The Ap Shall Be Equipped With A High-Performance 4-Core Qualcomm Chipset. Ram: 512Mb Ddr3. Antenna: Integrated Internal 4X4Dbi Dual-Band Mimo Antennas. Combined Rate: A Concurrent Wireless Rate Of Up To 3000 Mbps. Physical Interfaces: 1 X 10/100/1000Mbps Wan/Poe Port. 1 X 10/100/1000Mbps Lan Port. 1 X Reset Button. Provision For A Dc2.0 12V 1.5A Power Connector. Support For Power Over Ethernet (Poe) Following Ieee 802.3Af/802.3At Standards. Thermal Management: The Unit Shall Feature A Heat Sink With A Snap-On Structure And Special Surface Coating To Optimize Heat Dissipation. Indicators: Led Status Lights For Power, Cloud Connection, Lan Speed, 2.4Ghz Status, And 5.0Ghz Status. Audio & Network Management Quality Of Service: Must Support Wmm (Wireless Multimedia Prioritization). Roaming: Support For Seamless Roaming To Ensure Uninterrupted Connectivity For Mobile Clients. Deployment: Flexible Deployment Options Including Standalone Mode, Mobile App Management, And Zero Touch Provisioning (Ztp). Network Management: Support For Vlan Settings, Cloud Access (In Gateway Mode), And System Logging. Management: Support For Remote Configuration And Management. Maintenance: Features For Backup/Restore Configuration, Factory Reset, Scheduled Reboots, And Lifetime Firmware Upgrades. Security Requirements Encryption: Must Support Wi-Fi Protected Access 3 (Wpa3) And Wired Equivalent Privacy (Wep) 64-Bit, 128-Bit, And 156-Bit. Access Control: Integrated Mac Address Filtering And Wireless Access Control To Identify Authorized Devices. Management Security: Secure Socket Layer (Ssl) For Remote Management Login And The Ability To Block Ssid Broadcasting. Environmental & Reliability Operating Limits: Working Temperature: -10°C To 55°C. Storage Temperature: -40°C To 70°C. Humidity: 5% To 95% Non-Condensing. Protection: Esd: Air ±8K, Touch 6K. Electrical Surge: Common Mode 2K, Differential Mode 1K. Power Efficiency: Maximum Power Consumption Shall Not Exceed 16 Watts. Oem Warranty And Support Local Presence: The Original Equipment Manufacturer (Oem) Must Have An Authorized Service Center Or Registered Office In Madhya Pradesh (Proof Of Gst/Msme/Registration Required With Bid). Warranty: A 2-Year On-Site Hardware Replacement Warranty Is Required, With New Hardware Provided Within 12 Hours Of A Call Lock (No Refurbished Or Repaired Products). Technical Support: On-Site Support Must Be Available Within 6 Hours Of A Request. Future Warranty & Support: Oem Must Have Warranty And Support Pack Purchase Option Before Expiry Of Warranty Period For Next Years. Service Availability: The Oem Must Provide A 24X7 1800-Series Toll-Free Number With Support Available In The Local Hindi Language. Product Life Cycle: The Quoted Product Must Have A Life Cycle Of No Less Than 5 Years From The Date Of Supply, Including Lifetime Free Firmware And Technical Assistance. Certifications: The Product Must Be Ce, Fcc, Rohs, Iec 15408 And Iso 9001. Certified. Bidder Must Have To Submit Compliance On Oem Letter Head Along With Maf. , Network Wall Mount Rack Must Have To Supply And Installation Of 15U 500X550 Network Wall Mount Rack With Glass Door And Lock With Hardware, 6 Socket Industrial Pdu 15Amp With Mcb, Cable Manager, Fan, Hardware And Etc. , Goosneck Mic Cable, Speaker Cable In Meter, Installation And Accessories Complete Job Work With Required Cables, Frpvc Conduit, Accessories, Fitting, Installation And Etc.
Contract Date: Jun 09, 2026 Contract Value : 2.02 Lakh
Local Bodies No of Bidders 3
Madhya Pradesh View Result →
44.
Railways #11097440 AOC
Supply Of wall mounted split air conditioner , wall mounted split air conditioner type 2 ton of specifications: (1) classification by function : cooling only (2) star rating (iseer value range) :5 star (iseer value from >=5 to <=5.5) (3) compressor type as per bee star rating label : inverter ac - variable speed (4) eco-friendly refrigerant : yes (5) refriger ant ozone depletion potential is zero : yes (6) compliance to green ac related environmental friendly featur es complied :no (7) salient features::turbo mode,power saving mode,self diagnosis, mode,dry mode,cool mode,fan mode,air swing,timer,sleep mode,auto on/off,fan speed, control,power(on-off),temperature up/down (8) salient accessories :1 m (pvc insulated sheathed cables as per is:694), remote, user manual, warranty card (9) comprehensive warranty on air conditioner::machine (in years) :1 (10) warranty on com pressor (in years): 10 (11) optional warranty on pcb : same as machine warranty (12) number of free servi ces during the comprehensive warranty on air conditioner::machine : 2 services per year (13) installation & commissioning : with installation commissioning (14) other services provided ( inclusive in the scope of su pply) : 24*7 customer online service (15) optional accessories::work required (inclusive in the scope of s upply: suitable wall mount stand for outdoor unit (16) nominal marketing cooling capacity (in ton) : 2 ton make: make- hitachi, samsung, lg, voltas, godrej or similar [ warranty period: 12 months after the date of delivery ] ]
Contract Date: May 15, 2026 Contract Value : 5.40 Lakh
Government Departments No of Bidders 1
45.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 5.70 Lakh
Boards / Undertakings / PSU No of Bidders 4
Contract Date: Ref. Documents Contract Value : 69
Local Bodies No of Bidders 1
Contract Date: Ref. Documents Contract Value : 2.93 Crore
Government Departments No of Bidders 8
Chhattisgarh View Result →
Contract Date: Ref. Documents Contract Value : 16.50 Crore
Government Departments No of Bidders 1
TenderDetail
Loading tenders